1. Product Lineup
Frame A
Series
NF-C
Commercial
product
NF-S
Generalpurpose
product
125
NF30-CS
NF63-CV
NF32-SV
NF63-SV
250
400
630
800
NF125-CV
NF250-CV
400-CW
630-CW
800-CEW
NF125-SV
NF250-SV
400-SW
630-SW
800-SDW
NF250-SGV
400-SEW
630-SEW
800-SEW
NF250-LGV
NF250-HV
NF250-HGV
NF250-HEV
400-HEW
630-HEW
800-HEW
NF125-RGV
NF250-RGV
400-REW
630-REW
800-REW
NF125-UGV
NF250-UGV
400-UEW
250
400
630
800
800-SEW
NF125-SGV
NF-H
Highperformance
product
NF63-HV
NF-U
Ultra currentlimiting
breaker
Frame A
63
160
NF160-SGV
NF125-SEV
Series
30
32
NV-C
Commercial
product
NV-S
Generalpurpose
product
NV32-SV
NV-H
Highperformance
product
Frame A
Series
For motor
protection
30
32
MB
Motor breaker
MB30-CS
NF160-LGV
NF160-HGV
160
NV63-CV
NV125-CV
NV250-CV
400-CW
630-CW
NV63-SV
NV125-SV
NV250-SV
400-SW
630-SW
NV125-SEV
NV250-SEV
400-SEW
630-SEW
NV125-HV
NV250-HV
400-HEW
630-HEW
NV125-HEV
NV250-HEV
400-REW
125
250
NF63-CV MB NF125-SV MB
NF250-SV MB
NF32-SV MB NF63-SV MB
New models
800-HEW
1600
NF
NF
NF
1000-SEW 1250-SEW 1600-SEW
800-UEW
125
63
1250
NF250-SEV
63
NV63-HV
30
32
NF125-LGV
NF125-HV
NF125-HGV
NF125-HEV
1000
1000
1250
NF-C
NF63-CW
NF63-CV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF125-CW
NF125-CV
NF250-CW
NF250-CV
Same dimension
Change in instantaneous value of 250 A rated model (from 10 times to 12 times 20%)
Increase in breaking capacity
NF32-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF63-SW
NF63-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF125-SW
NF125-SV
NF125-SGW RT
NF125-SGV
NF32-SW
NF-S
Same dimension
Increase in breaking capacity
Capable of breaking 690 V AC
Change in depth (from 86 mm to 68 mm)
Change in rated current adjustable range
Adjustable instantaneous value Unadjustable
NF125-SGW RE
NF125-SEV
NF160-SW
NF160-SGW RT
NF160-SGV
NF160-SGW RE
NF250-SEV 80-160A
NF250-SW
NF250-SV
Same dimension
Change in instantaneous value of 250 A rated model (from 10 times to 12 times 20%)
Increase in breaking capacity
Capable of breaking 690 V AC
NF250-SGW RT
NF250-SGV
NF250-SGW RE
NF250-SEV
Series
NF-H
NF63-HW
NF63-HV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Change to running on both AC/DC
Increase in breaking capacity
NF125-HW
NF125-HV
Same dimension
Applicable to rated current of 125 A
Increase in breaking capacity
NF125-HGW RT
NF125-HGV
NF125-HGW RE
NF125-HEV
NF160-HW
NF160-HGW RT
NF160-HGV
NF160-HGW RE
NF250-HEV 80-160A
NF250-HW
NF250-HV
Same dimension
Applicable to rated current of 250 A (instantaneous value = 12 times 20%)
Increase in breaking capacity
NF250-HGW RT
NF250-HGV
NF250-HGW RE
NF250-HEV
NF125-RGW RT
NF125-RGV
Changes in dimensions (height: from 240 mm to 165 mm, depth: from 86 mm to 68 mm)
Change in rated current adjustable range
Applicable to rated current of 125 A
Increase in breaking capacity at 415 V AC or less
Rated working voltage of below 500 V AC
NF125-UGW RT
NF125-UGV
NF250-RGW RT
NF250-RGV
Changes in dimensions (height: from 240 mm to 165 mm, depth: from 86 mm to 68 mm)
Applicable to rated current of 250 A
Increase in breaking capacity at 415 V AC or less
Rated working voltage of below 500 V AC
NF250-UGW RT
NF250-UGV
NV63-CW
NV63-CV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV125-CW
NV125-CV
NV250-CW
NV250-CV
Same dimension
Increase in breaking capacity
NF-U
NV-C
Series
NV32-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV63-SW
NV63-SV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV125-SW
NV125-SV
Same dimension
Increase in breaking capacity
NV250-SW
NV250-SV
Same dimension
Increase in breaking capacity
NV250-SEW
NV250-SEV
Same dimension
Applicable to rated current of 250 A
Increase in breaking capacity
NV63-HW
NV63-HV
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
NV125-HW
NV125-HV
Same dimension
Applicable to rated current of 125 A
Increase in breaking capacity
NV250-HW
NV250-HV
Same dimension
Applicable to rated current of 250 A
Increase in breaking capacity
NV250-HEW
NV250-HEV
Same dimension
Applicable to rated current of 250 A
Increase in breaking capacity
MB50-CW
NF63-CV (Note)
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
MB30-SW
NF32-SV (Note)
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
MB50-SW
NF63-SV (Note)
Same dimension
Change of tripping method (from hydraulicmagnetic to thermal magnetic)
Changes in operating characteristics
Increase in breaking capacity
MB100-SW
NF125-SV (Note)
Same dimension
Increase in breaking capacity
MB225-SW
NF250-SV (Note)
NV32-SW
NV-S
NV-H
MB
Note: The circuit breakers for motor protection have the same basic model names as NF/NV.
New models
Model name
Remarks
Thermally adjustable models having breaking capacity of 50 kA at 440 V AC are newly introduced.
NV125-SEV, NV125-HEV
Electronic breakers
NF125-CV/SV/HV
NF250-CV/SV/HV
NF125-SGV/LGV/HGV NF125-RGV
NF250-RGV
NF125-SEV/HEV
NF160-SGV/LGV/HGV
NF250-SGV/LGV/HGV
NF250-SEV/HEV
No change
100
100
No change
No change
NV32-SW
NV63-CW/SW/HW
NV125-CW/SW/HW
NV250-CW/SW/HW
NV250-SEW/HEW
NV32-SV
NV63-CV/SV/HV
NV125-CV/SV/HV
NV250-CV/SV/HV
NV250-SEV/HEV
70
No change
Breaker
R
1
Breaker
R1
M40.7 screw
or 5 hole
No change
52
Front plate
cutout plan
52
R1
Breaker
35
52
No change
No change
126
111
M40.7
screw or
5 hole
30
25
Breaker
Breaker
111
Drilling
dimension
Breaker
Breaker
11.5
No change
M40.7 screw
or 5 hole
Breaker
M40.7
screw or
5 hole
86
100
No change
No change
100
change
R1
100
No change
52
52
52
Breaker
35
No change
52
1
R
No change
New
WS-V
Series
86
70
35 M40.7 screw
or 5 hole
change
No change
Breaker
Breaker
Front plate
cutout plan
Previous
W & WS
Series
No change
35 M40.7 screw
or 5 hole
R
1
Breaker
35 M40.7 screw
or 5 hole
52
No change
M40.7 screw
30 or 5 hole
R
1
M40.7 screw
or 5 hole
Breaker
Breaker
201
111
111
Drilling
dimension
25
Breaker
NF125-UGV
NF250-UGV
126
Breaker
Breaker
NF125-RGW/UGW
NF250-RGW/UGW
126
Breaker
52
NF32-SV
NF63-CV/SV/HV
NF160-SW/HW
NF250-CW/SW/HW
MB225-SW
126
New
WS-V
Series
NF125-CW/SW/HW
MB100-SW
R
1
NF32-SW
NF63-CW/SW/HW
Previous MB30-SW
W & WS MB50-CW/SW
Series
NF32-SW
NF63-CW/SW/HW
Previous MB30-SW
W & WS MB50-CW/SW
Series
New
WS-V
Series
NF32-SV
NF63-CV/SV/HV
NV32-SW
NV63-CW/SW/HW
NF125-CW/SW/HW
MB100-SW
NV125-CW/SW/HW
NV32-SV
NV63-CV/SV/HV
NF125-CV/SV/HV
NV125-CV/SV/HV
F-05S, F-05SE
F-05S2, F-05S, F-05SE
F-05SV, F-05SVE
F-05SV2, F-05SV, F-05SVE
S-05SW
S-05SV
V-05S, V-05SE
V-05SV, V-05SVE
F-1S, F-1SE
F-1SV, F-1SVE
F type
No change
S type
S-1SW
S-05SV
V-1S, V-1SE
V-1SV, V-1SVE
No change
No change
No change
No change
No change
No change
Distance between
circuit breaker
bottom and front
plate
V type
Previous models
New models
Previous models
New models
Previous models
New models
105 mm
No change
102 mm
No change
125 mm (stationary type)
No change
NF160-SW/HW
NV250-CW/SW/HW NF125-SGW/HGW
NF250-CW/SW/HW NV250-SEW/HEW NF160-SGW/HGW
Previous NF250-SEW/HEW
NF250-SGW/HGW
W & WS MB225-SW
Series
New
WS-V
Series
Previous models
New models
Previous models
New models
Previous models
New models
NF250-CV/SV/HV
NF250-SEV/HEV
NV250-CV/SV/HV
NV250-SEV/HEV
F-2S, F-2SE
F-2SV, F-2SVE
S-2SW
S-2SV
V-2S, V-2SE
V-2SV, V-2SVE
NF125-RGW/UGW
NF250-RGW/UGW
NF125-SGV/LGV/HGV NF125-RGV
NF125-SEV/HEV
NF250-RGV
NF160-SGV/LGV/HGV
NF250-SGV/LGV/HGV
NF250-SEV/HEV
NF125-UGV
NF250-UGV
F-2UG, F-2UGE
F-2SV, F-2SVE
S-2SV
V-2UG, V-2UGE
V-2SV, V-2SVE
F-2SG, F-2SGE
F-2SV, F-2SVE
S-2GSW
S-2SV
V-2SG, V-2SGE
V-2SV, V-2SVE
Center of circuit
breaker handle
F type
Center of
circuit
breaker
No change
Center of
operating
handle
V-2UV, V-2UVE
Center of circuit
breaker handle
Center of
circuit
breaker
and
operating
handle
No change
F-2UV, F-2UVE
M40.7 screw
or 5 hole
No change
M40.7 screw
or 5 hole
Previous model
New model
Diering in hole position
Center of circuit
breaker handle
S type
Center of
circuit
breaker
No change
Center of
circuit
breaker
and
operating
handle
No change
Center of
operating
handle
Center of circuit
breaker handle
M40.7 screw
or 5 hole
No change
M40.7 screw
or 5 hole
Previous model
New model
Diering in hole position
Center of circuit
breaker and circuit
breaker handle
Center of circuit
breaker and circuit
breaker handle
Breaker
Breaker
V type
Center of
circuit
breaker
No change
Center of
circuit
breaker
and
operating
handle
No change
Center of
operating
handle
No change
M40.7 screw
or 5 hole
M40.7 screw
or 5 hole
Distance between
circuit breaker
bottom and front
plate
Previous model
New model
Diering in hole position
No change
No change
No change
Previous models
125 mm
New models
107 mm
No change
Previous models
128 mm
Previous models
143 mm
(stationary type)
New models
110 mm
New models
125 mm
(stationary type)
No change
No change
Products
Previous models
New models
AL-05SW* AX-05SW*
ALAX-05SW*
AL-1SW AX-1SW ALAX-1SW
AL-2SW* AX-2SW*
ALAX-2SW*
AL-2GSW* AX-2GSW*
ALAX-2GSW*
AL-05SV* AX-05SV*
ALAX-05SV*
SHTMMMM-05SWR
CassetteSHTMMMM-1SWR
type
accessories
SHTMMMM-2SWR
(Note)
SHTMMMM-05SVR
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
NF/NV32-SV, NF/NV63-CV/SV/HV
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
SHTMMMM-2GSWR
UVTNMMMM-05SW*
NF/NV32-SV, NF/NV63-CV/SV/HV
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
UVTNMMMM-2SW*
UVTNMMMM-05SV*
UVTSMMMM-05SV*
UVTSMMMM-2GSW*
ST-05SW2, 3, 4
ST-05SV2, 3, 4
NF/NV32-SV, NF/NV63-CV/SV/HV
ST-1SW2, 3, 4
ST-1SV2, 3, 4
NF/NV125-CV/SV/HV(3, 4P)
ST-1HW2
ST-1HV2
NF125-HV(2P)
NF/NV250-CV/SV/HV
ST-2SV2, 3, 4
NF125-SGV/LGV/HGV/SEV/HEV,
NF250-SGV/LGV/HGV/SEV/HEV, etc.
PM-05SW2, 3, 4
PMDN-05SV2, 3, 4
NF/NV32-SV, NF/NV63-CV/SV/HV
PM-NV05SW2
PMDN-NV05SV2
NV63-CV/SV(2P)
PM-1SW2, 3, 4
PMDN-1SV2, 3, 4
NF/NV125-CV/SV/HV
PM-1HW2
PMDN-1HV2
NF125-HV(2P)
ST-2SW2, 3, 4
ST-2GSW2, 3, 4
Plug-in
terminal
(PM)
NF/NV32-SV, NF/NV63-CV/SV/HV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
UVTNMMMM-1SW*
Rear stud
(B-ST)
Compatibility
New breakers Previous
with previous breakers with
accessories new accessories
PM-2SW2, 3, 4
PM-2GSWIP2, 3, 4
PM-2GUW2, 3
NF/NV250-CV/SV/HV
PMDN-2SV2, 3, 4
NF125-SGV/LGV/HGV/SEV/HEV,
NF250-SGV/LGV/HGV/SEV/HEV, etc.
PMDN-2SV2, 3
NF125-RGV, NF250-RGV
PMDN-2UV2, 3
NF125-UGV, NF250-UGV
FB-05SV
Conductor
FB-1SW
(FB)
NF/NV32-SV,
NF/NV63-CV/SV/HV (50A or less)
FB-1SV
NF/NV125-CV/SV/HV
FB-2SW
FB-2SV
NF/NV250-CV/SV/HV
BAF-05SW
BAF-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV,
NF/NV125-CV/SV/HV, etc.
BAF-2SW
BAF-2SV
NF/NV250-CV/SV/HV, etc.
BAG-05SW3
BAG-05SV3
NF/NV32-SV, NF/NV63-CV/SV/HV
BAG-1SW3
BAG-1SV3
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV, etc.
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
FB-05SW
Barrier
BAG-2SW3
BAG-2GSW3
BAG-2SV3
Note: In *, a symbol indicating the mounting pole is shown. In M, the voltage is shown.
Models
Accessories
Products
Previous models
New models
F-05S2
F-05SV2
NF32-SV(2P), NF63-CV/SV/HV(2P)
F-05S
F-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
F-1S2
F-1SV2
NF125-CV/SV(2P)
F-1S
F-1SV
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
F-2SV
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
F-2UG
F-2UV
NF125-UGV, NF250-UGV
S-05SW
S-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
S-1SW
S-1SV
NF/NV125-CV/SV/HV
F-2S
F-2SG
Operating
handle
S-2SW
NF/NV250-CV/SV/HV
S-2SV
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
V-05S2
V-05SV2
NF32-SV(2P), NF63-CV/SV/HV(2P)
V-05S
V-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
V-1S2
V-1SV2
NF125-CV/SV(2P)
V-1S
V-1SV
NF/NV125-CV/SV/HV
S-2GSW
NF/NV250-CV/SV/HV
V-2SV
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
V-2UG
V-2UV
NF125-UGV, NF250-UGV
TG-S05SW
TG-S05SV
TG-S2SW
TG-S2SV
NF/NV250-CV/SV/HV, etc.
TCS-05SW2W, 3W, 4W
TCS-05SV2, 3, 4
NF/NV32-SV, NF/NV63-CV/SV/HV
TCS-1SW2W, 3W, 4W
TCS-1SV2, 3, 4
NF/NV125-CV/SV/HV
V-2S
V-2SG
Clamp
TC-S
NF/NV250-CV/SV/HV
TCS-2SV3, 4
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
TCL-05SW2W, 3W, 4W
TCL-05SV2, 3, 4
NF/NV32-SV, NF/NV63-CV/SV/HV
TCL-1SW2W, 3W, 4W
TCL-1SV2, 3, 4
NF/NV125-CV/SV/HV
TCL-2SV3, 4
NF/NV250-CV/SV/HV
TCL-2GSW3W, 4W
TCL-2SV3L
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
TTC-05SW2, 3
TTC-05SV2, 3
NF/NV32-SV, NF/NV63-CV/SV/HV
TTC-1SW2, 3
TTC-1SV2, 3
NF/NV125-CV/SV/HV
TCS-2SW3W, 4W
TCS-2GSW3W, 4W
TC-L
TTC
TCL-2SW3W, 4W
NF/NV250-CV/SV/HV
TTC-2SV3
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
BTC-05SW2W, 3W
BTC-05SV2, 3
NF/NV32-SV, NF/NV63-CV/SV/HV
BTC-1SW2W, 3W
BTC-1SV2, 3
NF/NV125-CV/SV/HV
TTC-2SW3
TTC-2GSW3
BTC
NF/NV250-CV/SV/HV
BTC-2SV3
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
PTC-05SW2W, 3W
PTC-05SV2, 3
NF/NV32-SV, NF/NV63-CV/SV/HV
PTC-1SW2W, 3W
PTC-1SV2, 3
BTC-2SW3W
BTC-2GSW3W
PTC
Compatibility
New breakers Previous
with previous breakers with
accessories new accessories
PTC-2SW3W
PTC-2SV3
PTC-2GSW3W
9
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
Models
Accessories
Products
Previous models
Lock cover
New models
LC-05SW
LC-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
LC-1SW
LC-1SV
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
LC-2SV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
HLF-05SW, HLN-05SW
HLF-05SV, HLN-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
HLF-1SW, HLN-1SW
HLF-1SV, HLN-1SV
NF/NV125-CV/SV/HV
NF/NV250-CV/SV/HV
HLF-2SV, HLN-2SV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
HLS-05SW, HLS-05SW2P
HLS-05SV, HLS-05SV2P
NF/NV32-SV, NF/NV63-CV/SV/HV
HLS-1SW, HLS-1SW2P
HLS-1SV, HLS-1SV2P
NF/NV125-CV/SV/HV
LC-2SW
LC-2GSW
HLF-2SW, HLN-2SW
HLF-2GSW, HLN-2GSW
Handle lock
NF/NV250-CV/SV/HV
HLS-2SV
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
NFS-05SW2P
NFS-05SV2P
NFS-05SW
NFS-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
NFS-1SW2P
NFS-1SV2P
NF125-CV/SV
NFS-1SW
NFS-1SV
NF/NV125-CV/SV/HV
HLS-2SW
HLS-2GSW
SBOX
Compatibility
New breakers Previous
with previous breakers with
accessories new accessories
NFS-2SW
NFS-2SV
NF/NV250-CV/SV, etc.
NFI-05SW
NFI-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
NFI-1SW
NFI-1SV
NF/NV125-CV/SV/HV
NFI-2SW
NFI-2SV
NF/NV250-CV/SV/HV, etc.
NFW-05SW
NFW-05SV
NF/NV32-SV, NF/NV63-CV/SV/HV
NFW-1SW
NFW-1SV
NF/NV125-CV/SV
NFW-1HW
NFW-1HV
NF/NV125-HV
NFW-2SW
NFW-2SV
NF/NV250-CV/SV/HV, etc.
MDSMMMM-NF1SWE
MDSMMMM-NF1SVE
NF125-CV/SV/HV
MDSMMMM-NV1SWE
MDSMMMM-NV1SVE
NV125-CV/SV/HV
MDSMMMM-NF2SWE
MDSMMMM-NF2SVE
NF250-CV/SV/HV
MDSMMMM-NF2GSWE MDSMMMM-NF2SVE
NF125-SGV/LGV/HGV/RGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/SEV/HEV, etc.
MDSMMMM-NV2SWE
MDSMMMM-NV2SVE
NV250-CV/SV/HV
Mechanical
MI-05SW3
interlock
MI-05SV3
NF/NV32-SV, NF/NV63-CV/SV/HV,
NF/NV125-CV/SV/HV, NF/NV250-CV/SV/HV,
NF125-SGV/LGV/HGV/RGV/UGV/SEV/HEV,
NF250-SGV/LGV/HGV/RGV/UGV/SEV/HEV, etc.
DIN-05SW
DIN-05SV
No new models
No new models
NF/NV250-SV or lower
IBOX
WBOX
Electric
operation
unit
(Note)
IEC 35 mm
rail mounting DIN-1SW2
adapter
DIN-1SW3
CH-P NO.5
Note: In *, a symbol indicating the mounting pole is shown. In M, the voltage is shown.
10
Models
Reference page
13
14
15
16
17
18
19
20
21
22
23
24
NV250-SEW, NV250-HEW
25
NV250-SEV, NV250-HEV
26
NF125-SGW, NF125-HGW,
NF160-SGW, NF160-HGW,
NF250-SGW, NF250-HGW
27
28
NF125-RGW, NF250-RGW
29
NF125-RGV, NF250-RGV
30
NF125-UGW, NF250-UGW
31
NF125-UGV, NF250-UGV
32
13
14
MB100-SW
17
NF125-SV (Note)
18
Note: The circuit breakers for motor protection have the same basic model names as NF.
11
Front connection
M5 0.8 screw
(M6 screw for 60 A and 63 A)
50
Mounting hole
Breaker
C
L
C
L
C
L
4.5
C
L
5.5
(6.5 for 60 A and 63 A)
6
Trip
button
8.5
50
111
C
L
24
84
C
L
M4 0.7 screw
or 5 hole
111
Insulating barrier
(removable)
C
L
130
C
L
25
22
25
50
50
75
75
100
45
Neutral pole
68
4
2-pole
3-pole
2-pole
3-pole
4-pole
72
90
4-pole
25
25
12.5 max.
61
Conductor drilling
for direct connection
Drilling plan
Rear connection
2-pole
M4 0.7 screw
or 5 hole
Insulating tube
Breaker
C
L
C
L
C
L
Breaker
C
L
C
L
50
C
L
M4 0.7 screw
for breaker mounting
M6 screw
25
14
25
27 min.
22.5
25
25
50
75
2-pole
3-pole
4-pole
50
42
70
68
72
R1
111
C
L
111
C
L
52
C
L
4-pole
3-pole
Drilling plan
Front-panel cutout
Plug-in
3-pole
4-pole
80
50
105
75
25
C
L
C
L
10
89
M6 screw
80
55
57
30
6.5
2-pole
Details of terminal
54
16.5 max.
25
21
54
Center of
circuit breaker
body
111
11
C
L
85
15.5
83.5
5.5
180
54
M5 0.8 screw
Mounting with terminal block
Mounting plate mounting nut or mounting
directly with screw
Plug-in terminal block
12
2-pole
25
50
82
107
3-pole
4-pole
Drilling plan
M5 0.8 screw
or 6 hole
M5 0.8 screw
(M8 screw for 60 A and 63 A)
Insulating barrier
(removable)
Mounting hole
25
50
75
50
75
100
45
8.5
22
25
Neutral pole
3-pole
25
25
61
68
4
2-pole
5.5
(8.5 for 60 A and 63 A)
8
Trip
button
111
4.5
50
112
130
50
24
12.5 max.
(16 max. for
60 A and 63 A)
2-pole
3-pole
4-pole
72
4-pole
Conductor drilling
for direct connection
90
Drilling plan
Rear connection
4-pole
2-pole
Breaker
50
M6 screw
(31 min. for 60 A and 63 A)
27 min.
68
M4 0.7 screw
for breaker
mounting
25
50
75
2-pole
3-pole
4-pole
70
50
25
52
22.5
25
14
25
42
R1
111
112
Breaker
112
27 min.
3-pole
Insulating tube
Mounting plate
t = 3.2 max.
Drilling plan
Front-panel cutout
Plug-in
Mounting plate
4-pole
80
105
50
75
3-pole
54
7
M6 screw
21
89
Details of terminal
25
55
30
80
54
116
16.5 max.
85
5.5
170
11
83.5
54
25
2-pole
6.5
57
2-pole
25
50
82
107
3-pole
4-pole
Drilling plan
13
M5 0.8 screw
or 6 hole
Trip button
61
Test button
50
C
L
45
Earth-leakage
indicating button
22
Breaker
C
L
5.5
(6.5 for 60 A and 63 A)
4.5
8.5
50
84
111
C
L
24
50
Sensitivity current
C
L switching unit
M5 0.8 screw
(M6 screw for 60 A and 63 A)
130
Mounting hole
111
Insulating barrier
(removable)
M4 0.7 screw
or 5 hole
25
12.5 max.
68
(Conductor thickness t = 5 max.)
75
72
Conductor drilling
for direct connection
90
Drilling plan
Rear connection
Mounting plate t = 3.2 max.
C
L
Breaker
Breaker
C
L
C
L
111
C
L
C
L
8
111
C
L
52
Insulating tube
14
50
70
M4 0.7 screw
for breaker mounting
25
M6 screw
27 min.
M4 0.7 screw
or 5 hole
50
68
72
42
Drilling plan
Front-panel cutout
Plug-in
M5 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
Mounting plate
50
16.5 max.
54
85
5.5
Center of
circuit breaker
body
54
83.5
180
11
C
L
111
15.5
80
54
80
21
10
Details of terminal
89
25
M6 screw
6.5
30
14
82
Drilling plan
M5 0.8 screw
(M8 screw for 60 A and 63 A)
50
24
Test button
68
12.5 max.
(16 max. for
60 A and 63 A)
72
61
50
4
75
45
8.5
22
Trip
button
Breaker
5.5
(8.5 for 60 A and 63 A)
4.5
50
Earth-leakage
indicating button
84
112
130
Sensitivity current
switching unit
M4 0.7 screw
or 5 hole
111
Insulating barrier
(removable)
Mounting hole
25
90
Conductor drilling
for direct connection
Drilling plan
Rear connection
M4 0.7 screw
or 5 hole
Mounting plate
t = 3.2 max.
Insulating tube
Breaker
50
14
70
25
68
52
R1
M4 0.7 screw
for breaker mounting
M6 screw
27 min.
112
112
111
Breaker
42
50
72
Drilling plan
Front-panel cutout
Plug-in
M5 0.8 screw
for mounting terminal block
Mounting plate
80
50
54
16.5 max.
7
5.5
80
54
116
170
85
11
83.5
54
21
89
25
M6 screw
82
30
6.5
Details of terminal
15
Drilling plan
M5 0.8 screw
or 6 hole
M8 screw
8.5
Breaker
C
L
C
L
C
L
C
L
22
30
60
60
90
90
2-pole
8.5
Trip
button
30
68
4
30
M4 0.7 screw
or 5 hole
3-pole
72
90
4-pole
30
2-pole
19 max. (comb-like
conductor: 16.5 max.)
61
Neutral pole
120
3-pole
45
4.5
50
84
112
C
L
Solderless terminal
for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
24
50
C
L
(Note 1)
110-111
Mounting hole
130
C
L
Insulating barrier
(removable)
C
L
Conductor drilling
for direct connection
4-pole
Drilling plan
Rear connection
4-pole
Stud rotatable by 90
C
L
2-pole
3-pole C
L
C
L
Breaker
C
L
52
R1
C
L
R1
112
C
L
112
16
Connecting
15 allowance
4-pole
Breaker
2-pole
Insulating tube
C
L
C
L
110-111 (Note 1)
Mounting plate
t = 3.2 max.
C
L
3-pole
102
30
8.5
30
M8 bolt
2-pole
2.5
15
2.5
54.5
15
M4 0.7 screw
for breaker mounting
60
68
30
Insulating tube
18
30
60
28
90
57
86
3-pole
4-pole
90
72
104.5
Front-panel cutout
Drilling plan
Plug-in
60
125
90
C
L
C
L
C
L
30
60
67
97
127
30
56
95
4-pole
134
54
C
L
11
C
L
190
20
98
5.5
3-pole
12
56
16.5 max.
30
21
12.5
M8 screw
89
30
8.5
65
2-pole
Details of terminal
94
M5 0.8 screw
Mounting with terminal block
Mounting plate mounting nut or mounting
directly with screw
Plug-in terminal block
2-pole
Conductor drilling drawing
3-pole
4-pole
Drilling plan
16
M5 0.8
screw or 6
hole
Insulating barrier
(removable)
Mounting hole
24
50
M8 screw
Breaker
8.5
Trip
button
30
22
30
60
60
90
90
120
111
4.5
50
84
130
112
8.5
19 max.
(comb-like conductor: 16.5 max.)
45
61
Neutral pole
3-pole
68
4
2-pole
72
3-pole
Conductor drilling
for direct connection
90
2-pole
30
30
4-pole
4-pole
Drilling plan
Rear connection
4-pole
4-pole
Insulating tube
3-pole
102
2-pole
Breaker
3-pole
Breaker
2-pole
30
8.5
30
15
68
72
15
M4 0.7 screw
for breaker mounting
60
2.5
54.5
30
18
60
M8 bolt
2.5
52
R1
R1
112
16
Connecting
15 allowance
112
111
Stud rotatable by 90
52
Mounting plate
t = 3.2 max.
Insulating tube
28
30
57
90
M4 0.7 screw
or 5 hole
90
2-pole
86
3-pole
4-pole
104.5
Drilling plan
Front-panel cutout
Plug-in
Mounting plate
M5 0.8 screw
Mounting with terminal
block mounting nut or
mounting directly with screw
3-pole
4-pole
95
125
60
90
M8 screw
21
8.5
89
30
2-pole
Conductor drilling
drawing
Remarks: 1. 2-pole model of NF125-SV are 3-pole models with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF125-CV.
17
56
12
30
65
Details of terminal
80
54
116
20 max.
85
5.5
170
11
83.5
56
30
67
97
127
2-pole
3-pole
4-pole
Drilling plan
M5 0.8 screw
or 6 hole
Sensitivity current
switching unit
Earth-leakage
indicating button
Earth-leakage
indicating button
C
L
C
L
Neutral pole
30
45
4.5
Trip
button
22
8.5
Breaker
C
L
Test button
Test button
Trip
button
Operating time
changing unit
Operating time
changing unit
(time delay type)
24
50
C
L
M8 screw
84
C
L
(Note 1)
110-111
C
L
Sensitivity current
switching unit
8.5
Mounting
hole
112
130
50
Insulating barrier
(removable)
30
60
90
90
120
3-pole
4-pole
30
19 max. (comb-like
conductor: 16.5 max.)
61
M4 0.7 screw
or 5 hole
68
4
72
3-pole
90
Conductor drilling
for direct connection
4-pole
Drilling plan
Rear connection
4-pole
4-pole
3-pole
102
3-pole C
L
C
L
Breaker
C
L
16
52
R1
C
L
112
110-111(Note 1)
C
L
52
Insulating tube
Connecting
allowance 15
C
L
Breaker
C
L
Stud rotatable by 90
112
Mounting plate
t = 3.2 max.
8.5
30
15
68
60
2.5
18
30
86
90
3-pole
104.5
28
30
60
Insulating tube
90
15
54.5
72
M8 bolt
2.5
M4 0.7 screw
for breaker
mounting
4-pole
Drilling plan
Front-panel cutout
Plug-in
4-pole
125
C
L
C
L
30
60
97
127
3-pole
4-pole
56
90
30
16.5 max.
21
M8 screw
12.5
89
8.5
60
30
Details of terminal
95
3-pole
18
Conductor drilling
drawing
56
12
134
98
54
C
L
11
C
L
190
20
5.5
94
Mounting plate
M5 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
Drilling plan
M5 0.8 screw
or 6 hole
M8 screw
50
111
4.5
50
22
8.5
Test button
Trip
button
Breaker
8.5
84
112
130
50
Sensitivity current
switching unit
Earth-leakage
indicating button
112
130
24
Operating time
changing unit
(time delay type)
30
19 max.
(comb-like conductor:
16.5 max.)
45
61
90
60
120
90
68
Neutral pole
30
M4 0.7 screw
or 5 hole
3-pole
72
30
4-pole
90
3-pole
Conductor drilling
for direct connection
4-pole
Drilling plan
Rear connection
4-pole
Insulating tube
3-pole
Breaker
Breaker
102
8.5
30
M4 0.7 screw
for breaker
mounting
M8 bolt
2.5
54.5
72
28
30
60
86
90
1.0 mm clearance on each side of the
handle frame
2.5
Insulating tube
68
18
30
60
15
52
R1
111
112
16
Connecting
allowance 15
112
Stud rotatable by 90
52
Mounting plate
t = 3.2 max.
4-pole
3-pole
90
15
3-pole
4-pole
104.5
Drilling plan
Front-panel cutout
Plug-in
Mounting plate
Plug-in terminal block
M5 0.8 screw
Mounting with terminal block
mounting nut or mounting
directly with screw
3-pole
4-pole
95
125
60
90
M8 screw
8.5
21
89
97
127
3-pole
30
Details of terminal
54
12
5.5
80
54
116
20 max.
85
83.5
11
170
54
30
19
4-pole
Drilling plan
M5 0.8 screw
or 6 hole
M8 bolt with
hexagon hole
24
100
Mounting hole
C
L
Breaker
C
L
C
L
22
35
70
105
105
140
126
10
4.5
50
45
Neutral
pole
35
61
35
M4 0.7 screw
or 5 hole
68
4
72
3-pole
92
3-pole
C
L
23 max.
8.5
100
Trip
button
165
144
C
L
102
8.5
Conductor drilling
for direct connection
4-pole
4-pole
Drilling plan
Rear connection
4-pole
68
144
126
C
L
52
8
144
M4 0.7 screw
for breaker
mounting
6
9
M8 bolt
70
71
72
C
L
C
L
15
15
C
L
C
L
20
Connecting
22 allowance
Breaker
C
L
Breaker
3-pole
Stud rotatable by 90
Insulating tube
C
L
3-pole
4-pole
Mounting plate
t = 3.2 max.
24
35
70
105
105
3-pole
106
100
35
M4 0.7
screw or
5 hole
Insulating tube
32.5
35
4-pole
Front-panel cutout
Drilling plan
Plug-in
4-pole
3-pole
Breaker (plug-in terminal block)
C
L
C
L
C
L
86
32
58.5
54
153
22
15
28
18
C
L
9
M8 bolt
20
70
70
105
Studs can be
installed in this
direction only.
105
107
142
3-pole
4-pole
Insulating barrier
Drilling plan
Remarks: 1. 2-pole models are 3-pole models with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF250-CW and only 3-pole models are available for the model of MB225-SW.
20
80
Connecting
allowance
70
14
M6 screw
for mounting
terminal block
144
C
L
200
58.5
34.5
Mounting plate
M8 bolt with
hexagon hole
Breaker
100
8
.5
24
10
Insulating barrier
(removable)
Mounting hole
126
4.5
50
102
144
165
25 max.
or
8.5
22
8.5
100
Trip
button
45
35
Neutral pole
70
25 max.
68
105
105
35
61
140
72
3-pole
M4 0.7 screw
or 5 hole
92
3-pole
Conductor drilling
for direct connection
4-pole
35
4-pole
Drilling plan
Rear connection
4-pole
Insulating tube
4-pole
Stud rotatable by 90
Breaker
3-pole
Breaker
M4 0.7 screw
for breaker
mounting
15
15
68
9
M8 bolt
24
35
70
70
52
100
35
105
4-pole
3-pole
106
32.5
35
M4 0.7
screw or
5 hole
Insulating tube
105
71
72
144
126
144
20
Connecting
allowance
22
Mounting plate
t = 3.2 max.
3-pole
Drilling plan
Front-panel cutout
Plug-in
4-pole 145
3-pole 110
34.5
31
112
30
54
56.5
20
M5 screw
for mounting
terminal block
21
89
15
28
151
11
70
144
165
190
24
56.5
Connecting
allowance
3-pole 70
Insulating barrier
4-pole 105
3-pole 105
9
M8 bolt
70
105
107
142
3-pole
4-pole
4-pole 140
Drilling plan
Remarks: 1. 2-pole models are 3-pole models with the central pole removed.
2. Only 2- and 3-pole models are available for the model of NF250-CV.
21
80
M5 0.8 screw
or 6 hole
C
L
Trip
button
100
Test button
22
35
70
Neutral
pole
105
105
45
61
68
23 max.
35
92
4-pole
35
72
140
3-pole
10
8.5
Test button
C
L
4.5
Earth-leakage
indicating
button
Operating time
changing unit
(time delay type)
C
L
8.5
50
144
C
L
165
Operating time
changing unit
(time delay type)
24
Sensitivity current
switching unit
102
Sensitivity current
switching unit
C
L
100
Mounting
hole
M8 bolt with
hexagon hole
126
Insulating barrier
(removable)
3-pole
4-pole
Conductor drilling
for direct connection
Drilling plan
Rear connection
4-pole
4-pole
Mounting plate
t = 3.2 max.
Stud rotatable by 90
Breaker
C
L
3-pole
3-pole
C
L
C
L
Breaker
C
L
C
L
52
126
144
144
C
L
20
Connecting
allowance 22
Insulating tube
C
L
15
68
71
72
15
9
M8 bolt
70
Insulating tube
35
24
35
70
105
3-pole
106
32.5
35
M4 0.7
screw or
5 hole
100
105
4-pole
Drilling plan
Front-panel cutout
Plug-in
4-pole
3-pole
C
L
80
58.5
22 Connecting
allowance
M6 screw
for mounting
terminal block
9
M8 bolt
18
70
20
70
86
32
58.5
153
15
28
70
14
C
L
C
L
54
C
L
C
L
34.5
144
200
Mounting plate
105
22
Studs can be
installed in this
direction only.
Insulating barrier
107
105
142
3-pole
4-pole
Drilling plan
M8 bolt with
hexagon hole
10
100
Sensitivity current
switching unit
Earth-leakage
indicating button
126
or
4.5
50
102
165
25 max.
144
144
Breaker
1
C
165
100
Operating time
changing unit
(time delay type)
24
8
.5
Insulating barrier
(removable)
Mounting hole
Trip
button
22
35
61
Neutral pole
70
105
105
140
68
4
3-pole
8.5
45
8.5
100
Test button
35
25 max.
(Conductor thickness t = 7 max.)
72
Conductor drilling
for direct connection
92
4-pole
35
M4 0.7 screw or 5 hole
4-pole
3-pole
Drilling plan
Rear connection
4-pole
Insulating
Mounting plate tube
Stud rotatable by 90
t = 3.2 max.
3-pole
4-pole
Breaker
Breaker
15
72
M4 0.7 screw
for breaker
mounting
15
68
9
M8 bolt
71
70
105
106
3-pole
52
1
R
35
M4 0.7
screw or
5 hole
Insulating tube
32.5
35
24
35
70
144
126
144
Connecting
allowance 22
20
3-pole
100
105
4-pole
Front-panel cutout
Drilling plan
Plug-in
4-pole 145
31
89
30
112
56.5
15
28
151
6
M5 screw
for mounting
terminal block
21
20
9
M8 bolt
3-pole 70
Insulating barrier
4-pole 105
3-pole 105
4-pole 140
23
80
56.5
24 Connecting
allowance
54
144
165
190
11
70
34.5
3-pole 110
70
105
107
142
3-pole
4-pole
Drilling plan
M5 0.8 screw
or 6 hole
NV250-SEW, NV250-HEW
70
140
3-pole
4-pole
23 max.
45
61
Neutral
pole
35
72
Conductor drilling
for direct connection
92
35
68
105
105
126
10
4.5
50
144
35
Tripping characteristic
switching unit
8.5
22
Overcurrent
test connector
100
Earth-leakage
test button
8.5
Sensitivity current
switching unit
Operating time
changing unit
(time delay type)
Trip
button
24
100
165
Mounting hole
3-pole
4-pole
Drilling plan
Rear connection
4-pole
4-pole
3-pole
Stud rotatable by 90
3-pole
15
68
M4 0.7 screw
for breaker
mounting
15
72
9
M8 bolt
Insulating tube
70
105
106
100
105
3-pole
52
32.5
35
M4 0.7
screw or
5 hole
70
71
35
24
35
R1
126
8
144
20
Insulating tube
22 Connecting
allowance
Breaker
Breaker
144
Mounting plate
t = 3.2 max.
4-pole
Front-panel cutout
Drilling plan
86
58.5
153
9
M8 bolt
70
20
32
80
54
58.5
22 Connecting
allowance
15
28
18
70
M6 screw
for mounting
terminal block
6
14
4-pole
3-pole
144
200
Mounting plate
34.5
Plug-in
107
70
105
24
105
142
3-pole
4-pole
Drilling plan
NV250-SEV, NV250-HEV
10
8
.5
Breaker
4.5
126
25 max.
50
or
102
144
8.5
100
Tripping
characteristic
switching unit
22
35
70
35
61
Neutral pole
105
105
45
8.5
144
Sensitivity current
switching unit
Earth-leakage
indicating button
Test button
Trip
button
24
100
100
Operating time
changing unit
(time delay type)
1
C
165
M8 bolt with
hexagon hole
165
Mounting hole
25 max.
68
4
140
72
Conductor drilling
for direct connection
92
3-pole
35
4-pole
3-pole
4-pole
Drilling plan
Rear connection
4-pole
Mounting plate
t = 3.2 max.
Insulating
tube
Stud rotatable by 90
3-pole
4-pole
Breaker
Breaker
15
68
72
M4 0.7 screw
for breaker
mounting
15
9
M8 bolt
71
Insulating tube
M4 0.7
screw or
5 hole
70
105
106
52
R1
32.5
35
24
35
70
144
144
20
22 Connecting
allowance
126
3-pole
35
100
105
3-pole
4-pole
Drilling plan
Front-panel cutout
Plug-in
4-pole 145
M5 screw
for mounting
terminal block
21
31
89
112
30
20
9
M8 bolt
3-pole 70
Insulating
barrier
4-pole 105
3-pole 105
4-pole 140
25
80
54
56.5
15
28
151
11
70
144
165
190
Mounting plate
56.5
24 Connecting
allowance
34.5
3-pole 110
70
105
107
142
3-pole
4-pole
Front-panel cutout
M5 0.8 screw
or 6 hole
Solderless terminal
for wire size
2.5 185 mm2
M8 bolt
(Hex-soket)
24
Breaker
50
Mounting hole
10
Insulating barrier
(removable)
126
4.5
50
22
35
8.5
63
Neutral
pole
70
105
105
140
3-pole
4-pole
35
10
22
8.5
50
Trip
button
112
165
144
6.1
79
86
4
35
M4 0.7 taps
or 5
3-pole
24 max.
4-pole
Drilling plan
90
(Bus t max. = 7)
110
Rear connection
4-pole
Insulating tube
Mounting plate
t = 3.2 max.
4-pole
3-pole
Stud can be
rotated 90
Breaker
3-pole
15
M4 0.7
screw for
breaker
mounting
6
15 9
M8 bolt
86
24
Insulating
tube
70
71
52
32.5
35
M4 0.7
taps
or 5
35
105
90
20
126
144
Connection
allowance
22
144
Breaker
100
35
105
70
106
3-pole
4-pole
Front-panel cutout
Drilling plan
Plug-in
Breaker (Terminal block)
4-pole
110
86
30
45
M6 screw
for mounting
terminal block
10
48
15
94
54
66
Connection
allowance
48
103
200
144
M8 bolt
(Hex-soket)
120
12
96
54
54.5
Mounting plate
70
105
107
20
70
Stud can be
rotated 90
9
M8 bolt
Insulating barrier
(removable)
Remark: 1. 2-pole models are 3-pole models with the central pole removed.
26
3-pole
142
4-pole
Drilling plan
M8 bolt with
hexagon hole
8
.5
24
10
100
Mounting hole
or
35
70
105
105
140
8.5
100
22
45
35
61
Neutral pole
M4 0.7 screw
or 5 hole
68
4
35
25 max.
72
92
3-pole
8.5
Trip
button
126
4.5
50
102
144
165
1
C
25 max.
3-pole
Conductor drilling
for direct connection
4-pole
4-pole
Drilling plan
Rear connection
4-pole
Insulating tube
4-pole
Stud rotatable by 90
Breaker
3-pole
Breaker
M4 0.7 screw
for breaker
mounting
15
15
68
9
M8 bolt
24
35
70
70
52
100
35
105
4-pole
3-pole
106
32.5
35
M4 0.7
screw or
5 hole
Insulating tube
105
71
72
144
126
144
20
Connecting
allowance
22
Mounting plate
t = 3.2 max.
3-pole
Drilling plan
Front-panel cutout
Plug-in
4-pole 145
3-pole 110
34.5
31
112
30
54
56.5
20
M5 screw
for mounting
terminal block
21
89
15
28
151
11
70
144
165
190
24
56.5
Connecting
allowance
3-pole 70
Insulating barrier
4-pole 105
3-pole 105
9
M8 bolt
70
105
107
142
3-pole
4-pole
4-pole 140
Drilling plan
Remark: 2-pole models are 3-pole models with the central pole removed.
27
80
M5 0.8 screw
or 6 hole
NF125-RGW, NF250-RGW
Solderless terminal
for wire size
2.5 185 mm2
M8 bolt
(Hex-soket)
4.5
50
112
165
201
240
219
6.1
50
Trip
button
35
70
105
22
8.5
22
Neutral
pole
79
140
(Bus t max. = 7)
Bus drilling for
direct connection
110
35
M4 0.7 taps
or 5
24 max.
90
4-pole
3-pole
35
63
86
105
Breaker
10
26.5
24
75
50
Mounting hole
3-pole
4-pole
Drilling plan
Rear connection
4-pole
Insulating tube
Mounting plate
Stud can be
t = 3.2 max.
rotated 90
3-pole
Breaker
4-pole
Breaker
3-pole
11.5
73
9
15 M8 bolt
24
35
70
Insulating
tube
71
70
M4 0.7
taps
or 5
32.5
35
100
35
105
105
90
52
219
20
M4 0.7 screw
for breaker
mounting
15
86
201
219
108
Connection
allowance
22
3-pole
106
4-pole
Drilling plan
Front-panel cutout
Plug-in
Plug-in terminal block
58.5
34.5
Mounting plate
18
104
32
155
129
58.5
28
153
70
14
15
219
275
22
Connecting
allowance
M6 screw
for mounting
terminal block
20
70
9
M8 bolt
Insulating
barrier
70
107
Drilling plan
Remark: 2-pole models are 3-pole models with the central pole removed.
28
NF125-RGV, NF250-RGV
Insulating barrier
(removable)
10
8
.5
Front connection
M8 bolt with
hexagon hole
24
1
C
Mounting hole
25 max.
8.5
Breaker
25 max.
45
22
61
70
68
4
105
4.5
8.5
Trip
button
50
102
or
35
M4 0.7 screw
or 5 hole
72
92
3-pole
Conductor drilling
for direct connection
3-pole
Drilling plan
Rear connection
Insulating tube
3-pole
Stud rotatable by 90
Breaker
3-pole
Breaker
15
68
M4 0.7 screw
for breaker
mounting
6
15
9
M8 bolt
35
70
32.5
24
Insulating tube
70
71
72
52
144
20
Connecting
allowance
22
Mounting plate
t = 3.2 max.
M4 0.7
screw or
5 hole
3-pole
106
Drilling plan
100
Front-panel cutout
Plug-in
Breaker (plug-in terminal block)
3-pole 110
34.5
28
15
151
11
70
144
165
190
24
Connecting
allowance
M5 screw
for mounting
terminal block
21
31
89
20
30
70
3-pole 70
Insulating barrier
3-pole 105
112
9
M8 bolt
Studs can be installed
in this direction only.
107
3-pole
Drilling plan
Remark: 2-pole models are 3-pole models with the central pole removed.
29
NF125-UGW, NF250-UGW
Solderless terminal
for wire size
2.5 185 mm2
M8 bolt
(Hex-soket)
4.5
50
112
165
201
240
219
6.1
50
Trip
button
35
70
105
22
8.5
22
Neutral
pole
79
140
(Bus t max. = 7)
Bus drilling for
direct connection
110
35
M4 0.7 taps
or 5
24 max.
90
4-pole
3-pole
35
63
86
105
Breaker
10
26.5
24
75
50
Mounting hole
3-pole
4-pole
Drilling plan
Rear connection
4-pole
Insulating tube
Mounting plate
Stud can be
t = 3.2 max.
rotated 90
3-pole
Breaker
4-pole
Breaker
3-pole
11.5
73
9
15 M8 bolt
24
35
70
Insulating
tube
71
70
M4 0.7
taps
or 5
32.5
35
100
35
105
105
90
52
219
20
M4 0.7 screw
for breaker
mounting
15
86
201
219
108
Connection
allowance
22
3-pole
106
4-pole
Drilling plan
Front-panel cutout
Plug-in
Plug-in terminal block
58.5
34.5
Mounting plate
18
104
32
155
129
58.5
28
153
70
14
15
219
275
22
Connecting
allowance
M6 screw
for mounting
terminal block
20
70
9
M8 bolt
Insulating
barrier
70
107
Drilling plan
Remark: 2-pole models are 3-pole models with the central pole removed.
30
NF125-UGV, NF250-UGV
M8 bolt with
hexagon hole
28
24
8.5
45
35
201
10
4.5
50
165
102
240
100
Trip button
22
23 max.
35
Neutral pole
68
70
105
140
3-pole
4-pole
35
61
105
Breaker
Solderless terminal
for wire size
125~175A 14~95mm2
200~250A 70~125mm2
Wire connection
8.5
165
219
75
75
100
Mounting hole
Conductor drilling
for direct connection
72
92
3-pole
4-pole
Drilling plan
Rear connection
4-pole
Mounting plate
t = 3.2 max.
3-pole
Insulating
tube
Stud rotatable by 90
4-pole
Breaker
Breaker
3-pole
11.5
73
15
15
9
M8 bolt
70
71
72
219
M4 0.7 screw
for breaker
mounting
Insulating tube
105
24
32.5
35
100
35
35
70
106
M4 0.7 screw
or 5 hole
3-pole
52
R1
20
22
68
201
Connecting
allowance
219
108
105
4-pole
Front-panel cutout
Drilling plan
31
89
56.5
20
28
21
56.5
15
151
70
11
155
219
265
M5 screw
for mounting
terminal block
Breaker
(plug-in terminal block)
110
129
Connecting
allowance
24
Mounting plate
34.5
Plug-in
70
Insulating barrier
30
105
9
M8 bolt
Studs can be installed
in this direction only.
70
M5 screw or 6 hole
107
Drilling plan
Remark: 2-pole models are 3-pole models with the central pole removed.
31
MEMO
Company
Mitsubishi Electric Australia Pty. Ltd.
Address
348 Victoria Road, Rydalmere, N.S.W. 2116, Australia
Telephone
+61-2-9684-7777
Chile
Rhona S.A.
Agua Santa 4211 P.O. Box 30-D Vina del Mar, Chile
+56-32-2-320-600
China
+ 86-21-2322-3030
China
+ 852-2887-8810
+57-4-235-30-38
+20-2-27961337
+49-(0)2102-486-0
+62-(0)21-6610651-9
+82-2-3660-9572
Colombia
Egypt
Europe
P. T. Sahabat Indonesia
Korea
Laos
+856-21-215043
Lebanon
+ 961-1-240445
Malaysia
+603-5569-3748
+95-(0)1-202589
+977-1-4411330
Indonesia
Myanmer
Watt&Volt House
Comptoir d'Electricite
Generale-International-S.A.L.
+ 961-1-240430
+92-(0)42-7654342
+63-(0)2-634-8691
+966-1-4770149
+ 65-6473-2308
+27-(0)11-9282000
+886-(0)2-2298-8889
Thailand
+66-223-4220-3
Uruguay
+598-2-902-0808
Adesco S.A.
+ 58-212-241-9952
+ 84-8-838-6727/28/29
Nepal
Other Middle East
Arab Countries & Cyprus
Pakistan
Philippines
Saudi Arabia
Singapore
South Africa
Taiwan
Venezuela
Vietnam
Safety Tips : Be sure to read the instruction manual fully before using this product.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN