MAHIMTURA CONSULTANTS PVT.

LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

H.R.C. REPORT

C/ 6589 /2014
PROJECT

Date:10/04/2014

PROPOSED RESIDENTIAL TOWER AT CURRY ROAD MUMBAI

CLEINT

M/S. NISH DEVELOPERS PVT. LTD.

ARCHITECT

VIVEK BHOLE

STRUCTURAL CONSULTANT

M/S. MAHIMTURA CONSULTANTS PVT. LTD.

GEO-TECH CONSULTANTS

PROF. G. B . CHAUDHARI

I am here with submitting the check list as a main structural consultant as per prescribed format as
follows
Design Basis Report as per the document HRC/DBR/V1.0.
Description of Sub-structure and Super- structure as per the format given in the Appendix
enclosed.
Brief Description of structural system:
Structural system comprise of framed columns, shear wall & flat slab system
Brief note on modeling:
Basic modeling has been generated in our customized interface program along with all primary
loadings and the same is exported in Etabs ver. 9.7.4 for analysis. The output of the analysis is
modified again by customized interface package for in house design module.
Whether infill/ partition wall is idealized as part of lateral load resisting system = No
a) Zone Factor
=
0.16
b) Importance factor
=
1.0
c) Response Reduction factor
=
4.0
d) Soil Type
=
I
e) % LL considered in seismic
UPTO 3KN/M2
=
25 %
ABOVE 3KN/M2
=
50%
f) Time Period in the horizontal X-direction
=
2.15 sec
(from formula in code)
g) Time Period in the horizontal Z-direction
=
3.02 sec
(from formula in code)
h) Total Seismic weight (Sw) of building (in kN)
=
3978616.56 kN
i) Static Base-shear in X-direction (as % of Sw)
=
0.93 %
j) Static Base-shear in Z-direction (as % of Sw)
=
0.66 %
k) Table of distribution for static base shear
=
Attached sheet No. 1
l) Max. deflection at roof level.
=
240 mm for EQ X
m) Max. inter storey drift.
=
1 / 752
1)

Wind loading details.


a) Category of building

III
Page No. 1

MAHIMTURA CONSULTANTS PVT. LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

b)
c)
d)
e)
f)
g)
h)
i)
j)

Class of building
Basic wind speed in m/sec.
Maximum wind pressure
Force coefficient
Wind Base-shear in the horizontal X-direction
Wind Base-shear in the horizontal Z-direction
Gust factor calculations (if Gust- wind applied)
Details of wind tunnel force data (if applicable)
Estimate magnitude of wind induced vibrations

=
=
=
=
=
=
=
=
=

k) Max. deflection at roof level.


l) Max. inter storey drift.
m) Data from Dynamic Analysis.
Modes
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Mode 8
Mode 9
Mode 10
Mode 11
Mode 12
Mode 13
Mode 14
Mode 15
Mode 16
2)

3)

=
=

Frequency Time Period


0.155
6.45
0.143
5.99
0.168
5.95
0.574
1.74
0.628
1.59
0.645
1.55
1.162
0.86
1.298
0.77
1.351
0.74
1.851
0.54
2.083
0.48
2.173
0.46
2.564
0.39
2.857
0.35
3.031
0.33
3.334
0.30
SUMMATION

C
44 m/sec
-1396.2 KN WT4
N/A
29436 KN
45143 KN
N/A
ENCLOSED
5.5 milli.g in x direction
and 5.5 milli-g in y
240 mm FOR WT1
1 / 867

X participation
47.02
1.47
12.75
8.99

7.29
0.05
3.40
2.59
0.01
2.23
1.47
0.004
1.869
1.108
0.001
1,372
91.65

Z participation
0.007
55.55
5.56
0.005
0.1992
16.85
0.003
0.040
6.222
0.002
0.026
3.73
0.001
0.011
2,86
0.001
91.12

Table for lateral deflection at Terrace Level.


Load
Case
DL

Dx-max
(mm)
2.63

DL + LL
EQx
EQz
Wx
Wz

H/Dz

Drift-Z

0.000019

Dz-max
(mm)
9.63

26812

0.000126

82229

0.000022

7.7

33532

0.000121

111.7
258200
7834
4579

0.000983
0.00001
0.000155
0.000250

0.03
145.75
180
143.6

258200
1772.5
1434
1798

0.00002
0.000646
0.000787
0.000629

H/Dx

Drift-x

98174

3.14
231
0.13
32.96
56.39

Table for Torsional irregularity (along x-direction).

Page No. 2

MAHIMTURA CONSULTANTS PVT. LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

Load Case

Corner Corner Corner


1
2
3

Eq-x (mm)
Wind-x (mm)
4)

Eq-z (mm)
Wind-z (mm)

6)

%
Max./Avg.

218
62

224
58

103
110

217
64

Corner Corner Corner


1
2
3
145
179

146
170

146
168

Corne
r 4

Avg-x

%
Max./Avg.

145
167

145.5
171

100.34
104.6

Acceleration values.
Eq-x

Eq-z

Eq-x

Eq-z

WL-x

WL-z

(Static)

(Static)

(dyn)

(dyn)

mili G

mili G

0.46

0.33

0.16

0.16

5.5

5.5

Data for Vertical Elements.


a)
b)
c)
d)
e)
f)
g)
h)

7)

230
52

Avg-x

Table for Torsional irregularity (along z-direction).


Load Case

5)

231
54

Corne
r 4

Size of maximum loaded column


Gravity load on max. loaded column
Axial stress in max. loaded column (Gravity loads)
Grade of max. loaded column
Axial settlement in max. loaded column
Axial settlement in min. loaded column
% Base-shear resisted by all columns along X (static)
% Base-shear resisted by all columns along Z (static)

=
=
=
=
=
=
=
=

1.95x1.85 mtrs
33223 K N
9.2 N/mm2
M60
2.58 mm
0.06 mm
N / A
N / A

Data for Floating Columns.


a) Total gravity load on floating column
FC3
N / A

FC4
N / A

FC5
N / A

FC6
N / A

FC7
N / A

b) Size and span of Girders supporting floating columns

B
D

FC8
N / A

=
=

N / A
N / A
Page No. 3

MAHIMTURA CONSULTANTS PVT. LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

L
Number of floors supported by floating columns
c) Deflecting of Girders under column (from model)
d) Deflecting of Girders under column (from s/s action)
e) Specific details about floating columns on cantilever Girders
8)

N
N
N
N
N

/
/
/
/
/

A
A
A
A
A

=
=
=
=
=

N.A
N.A
N.A
N.A
N.A

=
=
=
=

4.25 m
Overhang
Balcony
7.5 mm

Data for soft story effect.


a)
b)
c)
d)
e)

9)

=
=
=
=
=

Stiffness of lower floor (in deflection/KN)


Stiffness of upper floor (in deflection/KN)
Relative stiffness ratio (upper/ lower)
Level of soft story
Number of floors above soft story

Data for each cantilever.


a) Cantilever span
b) Structural system
c) Nature of usage
d) Maximum elastic deflection under gravity loads

10)

Provide stability calculations for uplift and overturning (model extract in case of model)
: Attached soft copy of safe Extract xl sheet which shows no uplift in any of the piles

11)

Typical design calculations for footings : Attached in the calculation report

12)

Typical design calculations for RCC columns : Attached in the calculation report

13)

Typical design calculations for RCC walls : Attached in the calculation report

14)

Typical design calculations for RCC beams (or Steel Beams) : Attached in the calculation
report

15)

Typical design calculations for RCC Girders (Or Steel Girders/


Trusses)
: Attached in the calculation report N.A.
Typical design calculations for Steel Bracings : N.A

16)
17)

Wind tunnel studies shall be conducted for any HRB with total height beyond normal
ground level exceeding 250 mt. Wind tunnel study shall include modeling of all
surrounding obstacles in the area. The report from study should be submitted. : REPORT
ENCLOSED

18)

Provide a note on special provisions suggested for the building (like dampers etc.) : N.A

19)

Soft copy of model including input and output. Attached

20)

Soft copy of Power point presentation including all above points. Attached

21)

Typical design calculations for RCC Girders (Or Steel Girders/ Trusses) : N / A
Page No. 4

MAHIMTURA CONSULTANTS PVT. LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

22)

Typical design calculations for Steel Bracings : N.A

23)

Wind tunnel studies shall be conducted for any HRB with total height beyond normal
ground level exceeding 250 mt. Wind tunnel study shall include modeling of all
surrounding obstacles in the area. The report from study should be submitted. : REPORT
ENCLOSED

24)

Provide a note on special provisions suggested for the building (like dampers etc.) : N.A

25)

Soft copy of model including input and output. Attached

26)

Soft copy of Power point presentation including all above points. Attached

27)

Items 1 through 26 on CD.

Page No. 5

MAHIMTURA CONSULTANTS PVT. LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

APPENDIX
DESCRIPTION OF SUB-STRUCTURE
NO. OF BASEMENT
Minimum
clearance
between
outermost basement retaining wall
and compound wall

Has a shoring system been installed?


Submit sectional detail of the shoring
system

N / A

Give details of methodology used to


resist uplift pressure due to ground
water for tower portion as well as the
portion outside the tower.

Description of the foundation for the


tower block
Nature of Foundation

3 MTRS

Bottom Level of Raft w.r.t. ground


level in mts.
Total downward load of self weight
of raft + Counter weight over raft +
Rock Anchors if any(for raft
spanning between columns)
Whether level assumed for uplift
calculation
RAFT, INDIVIDUAL FOOTINGS,
COMBINED FOOTINGS
RAFT, INDIVIDUAL FOOTINGS,
COMBINED FOOTINGS

SBC assumed T/sq.mt.


Sub-grade Elastic Modulus
Flooring system of the Basements
Retaining wall types & Sequence of
backfilling

300 T/M2
300000 K N /M3
N / A
N / A

Intended Use of basements

N / A

If rock anchors are used, are they


grouted
after
installation
and
stressing?
Is structural steel used in the
construction of the sub-structure?
If yes, what are the measures taken for
its fire proofing and corrosion
resistance?
Whether Expansion/Separation joints
provide?
Whether expansion joint/separation
joint continues through basement?
If yes, detail at Basement level &
retaining wall junction

5 MTRS
7.5 KN/M2+19.8KN/M2+25mm
dia @ 2000 mm c/c

YES

N / A
N / A
N.A.
N.A.

N / A
PROPPED
CANTILEVER
WALL.
BACKFILLING
IS
AFTER FULL STRENGTH OF
RETAINING WALL
PARKING AND
SERVICESS
YES
N.A
N.A
N.A
N.A
N.A

Page No. 6

MAHIMTURA CONSULTANTS PVT. LTD

Project :- RESIDENTIAL TOWER FOR NISH DEVELOPERS


PVT LTD CURRY ROAD MUMBAI

DESCRIPTION OF STRUCTURE
The RESIDENTIAL Building consists of Lower
Basement + Ground floor + 9 Podium Floor +
No. of Floors

Service Floor + 56 Typical floors + Terrace &


LMR / OHT

Shape Of Building, Plan, Elevation whether


Symmetric in Elevation
Maximum plan dimension in either direction
in mt.
Ratio of plan dimension
Typical Floor to floor height in mt.
Maximum floor to floor height in entire
height of building in mt.
Aspect ratio (Height of building till Terrace/
Minimum Dimension of Building)
Type of floor slab
Average thickness of floor slab in mm.
Whether column are RCC, Composite or In
structural steel
Lateral System
Whether the Geometry of Building is
Symmetric
Whether the lateral load resisting system is
symmetrically placed in Geometry
Use of floor at different levels (Residential /
Commercial / industrial)
Is there any Transfer level?
If yes, depth of Transfer Girder
Whether Expansion joint is provided?
If yes, what is the maximum plan dimension
in mt.
Whether separation gap is sufficient joint is
provide?
Maximum cantilever projection in mt.

CURVED ( SEE PLAN )


YES
L = 112.65 m
B = 54.7 m
L/B = 2.05
3.85 m
6 m
H/B = 4.66
RCC
225 mm
RCC
Shear walls in the core portion
YES
YES
RESIDENTIAL

N.A
N.A
N.A
4.25m (beam)

Page No. 7