Sei sulla pagina 1di 2

TYPE CARTRIDGE FILTER

KIEKENS
DUSTMASTER
DM6000 / DM7000

Cartridge Dustmasters are


designed for continuous
operation even during
the cleaning cycle.
High efficiency ensures
separation of even very
fine, sticky and health
hazardous dusts in
the metal, synthetic
material, chemical and
pharmaceutical industry.

IND. VACUUM TECHNOLOGY

filter unit

DM6000 l x w x h (max.) = 1090 x 810 x 3545

DM7000 l x w x h (max.) = 1350 x 1070 x 3930

6KVE280 2.2kW
6KVE280 3kW
curve

8KTE280 4kW

curve

DM6000

12KSE280 5.5kW DM7000

6KVE315 3kW

6KVE315 4kW

12KVE315 5.5kW

8KTE315 7.5kW

pos. 4

pos. 3

pos. 2

pos. 1

KIEKENS CARTRIDGE FILTER

12KSE315 11kW

8FVE400 7.5kW

12KRE315 11kW

12FTE400 11kW

4 x 13 = 52 m2

3 x 13 = 39 m2

5 x 13 = 65 m2

filter

4 x 13 = 52 m2

filter

6 x 13 = 78 m2

area

2 x 20 = 40 m2

area

4 x 20 = 80 m2

DM6000

3 x 20 = 60 m2

DM7000

5 x 20 = 100 m2

6 x 20 = 120 m2

filter

fluid and oil resistant, extra wear proof M* cartridge

quality

fluid and oil resistant, anti static M* cartridge

fluid and oil resistant, M* cartridge (PTFE)

4
5

fluid and oil resistant, anti static M* cartridge* (PTFE)

example code DM

Inlet adapter: to connect the inlet on different pipe


diameters ( 224, 250, 280, 315, 355, 400 mm).

Outlet with grill (standard): or with elbow


and/or with silencer.

Switchboxes: direct-in without '0' or direct-in


without '0' with relay; 2.2, 3 or 4 kW.

Pressure difference gauge: indication of the


pressure downfall over the filtercartridge
(filter pollution).

Pressure differential switch: for adjustment of


the pulse time and interval time, dependent on
the maximum allowable pressure downfall.

Transition funnel with flange: for connecting


a rotary valve.

Mounting frame: for mounting on a bunker or


silo as a venting filter.

Outdoor installation: weather hood and moisture


resistant cartridges.

HEPA filter.

Active carbon filter.

8KSE315 7.5kW

2 x 13 = 26 m2

4 x 20 = 80 m2

Options:

* Dust class M, permeability <0.1 %.

Relation between static suction pressure and air flow

0,75

1,25

2,25

2,50

2,75

500

4500

450

4000

400

3500

350

3000

2500
2000

300
250

200

150

1500

3,25

1000

100
50

500

2
1.000

5
6

2.000

3.000

4.000

5.000
6.000
V [m3/h]

7.000

8.000

9.000

10.000

11.000 12.000

Operation:
The dust laden air flows through the inlet in the preseparator room 2 . The relatively heavy dust is separated
there immediately and falls into the dust container 6 (DM6000: 55 l and DM7000: 70 l). The rest of the dust in
the polluted air is being filtrated on the exterior of the filter cartridges and falls into the dust container as well 6 .
The clean air flows through the pores of the filtermaterial to the clean air room. The air will in principle be
carried back into the work area but can also be blown into the atmosphere. Without any interruption of the
activity 1 filter cartridge is recurrently being cleaned by means of compressed air. Because of the compressed
air a cartridge is being cut off with a valve in order for the spindle to come in rotation. Because of this the filter
material is being blown through fold by fold by means of blow pipes 3 and the dust layer built up on the
filtermaterial falls through the cone 5 in the dustbin. The construction is designed in such a modular way that
the inlet 2 , the inspection panel 4 , the fan housing 1 and the dustbin 6 can be constructed in different
ways towards each other.

ISO 9001

Accredited by the
Dutch Council for
Accreditation

Kiekens Products B.V.


P.O. Box 99
7600 AB Almelo - NL
tel. +31(0) 546 - 87 15 55
fax +31(0) 546 - 87 19 85
www.kiekens-products.com
info@kiekens-products.com

1045932 No legal rights can be derived from this publication. Specifications may be changed without prior notice. 08-2003.