Sei sulla pagina 1di 7

Sunergy

a solar control glass with pyrolytic low-e coating

You have printed


Grey, Green, Clear, Dark Blue, Azur

Infosheet

Sunergy
a solar control glass with pyrolytic low-e coating

Low-reflecting solar-control glasses with thermal insulation properties


Superb appearance and visual comfort: high light transmission, low reflection and neutral

appearance
Interior comfort: excellent thermal insulation thanks to its low E coating and high solar control

properties
Hard-coated glass (coating applied using a pyrolitic process) can be processed in many ways,

including toughening
Sunergy low-reflecting solar-control glasses with Low E properties offering architects limitless

creativity: a single glass can be used for all applications


Application: single glass - double glazed units - laminated glass - toughened glass - enamelled glass
Benefits

Superb appearance and visual comfort: high light transmission and low reflection
Especially neutral on clear float glass
Interior comfort: excellent thermal insulation combined with solar control
Low emissivity coating
Can be processed easily
Limitless creativity for the architect: one type of glass for all applications

Sunergy
a solar control glass with pyrolytic low-e coating

Grey

Admired for its grey colour providing superb solar control


The perfect choice for all seasons: warm in winter, cool
in summer
Multiple applications: atriums, south-facing faades, etc.

Performances
Grey
Structure

6| - 16 Ar 90% - |4

Light properties (EN 410)

Energy Properties

Ug-Value

LT%

LR%

EA%

SF%

SC%

W/(m.K)

29

72

26

0.3

1.1

Sunergy
a solar control glass with pyrolytic low-e coating

Green

Admired for its green colour providing superb solar


control
The perfect choice for all seasons: warm in winter, cool
in summer
Multiple applications: atriums, south-facing faades, etc.

Performances
Green
Structure

Light properties (EN 410)

Energy Properties

Ug-Value

LT%

LR%

EA%

SF%

SC%

W/(m.K)

6|

56

63

41

0.47

4.1

6| - 12 Air - 6

50

10

67

33

0.38

2.2

6| - 12 Ar - |6

49

69

31

0.36

1.3

6| - 15 Ar - |6

48

70

29

0.33

1.1

6| - 15 Ar - |6

49

69

30

0.34

1.1

6| - 16 Ar 90% - |4

49

69

29

0.33

1.1

8|

52

68

38

0.44

4.1

Sunergy
a solar control glass with pyrolytic low-e coating

Clear

Admired for its neutral appearance and low reflection


thanks to its clear colour
The perfect choice for all seasons: warm in winter, cool
in summer
Multiple applications: double-skin faades, atriums, etc.

Performances
Clear
Structure

Light properties (EN 410)

Energy Properties

Ug-Value

LT%

LR%

EA%

SF%

SC%

W/(m.K)

10|

66

41

57

0.66

4.0

4|

69

34

61

0.7

4.1

6|

68

37

60

0.69

4.1

6| - 12 Air - 6

61

12

43

52

0.6

2.2

6| - 12 Ar - |6

59

11

48

47

0.54

1.3

6| - 15 Ar - |4

59

11

48

44

0.51

1.1

6| - 15 Ar - |6

59

11

48

47

0.54

1.1

6| - 16 Ar 90% - |4

59

11

48

44

0.51

1.1

8|

67

39

59

0.68

4.1

Sunergy
a solar control glass with pyrolytic low-e coating

Dark Blue
The best solar protection from the entire range
(30%) - Sc= 0.34

Very attractive blue colour

Low light reflection

Performances
Dark Blue
Structure

Light properties (EN 410)

Energy Properties

Ug-Value

LT%

LR%

EA%

SF%

SC%

W/(m.K)

6|

40

68

37

0.43

4.1

6| - 12 Air - 6

36

72

29

0.33

2.2

6| - 12 Ar - |6

35

74

25

0.29

1.2

6| - 15 Ar - |6

35

74

25

0.29

1.1

6| - 15 Ar - |6

35

74

26

0.3

1.1

Sunergy
a solar control glass with pyrolytic low-e coating

Azur

Admired for its blue tint which bolsters its solar control
properties
The perfect choice for all seasons: warm in winter, cool
in summer
Multiple applications: faades exposed to sunshine,
atriums, conservatories, etc.

Performances
Azur
Structure

Light properties (EN 410)

Energy Properties

Ug-Value

LT%

LR%

EA%

SF%

SC%

W/(m.K)

10|

48

68

37

0.43

4.0

6|

56

60

44

0.51

4.1

6| - 12 Air - 6

50

10

63

36

0.41

2.2

6| - 12 Ar - |6

49

66

33

0.38

1.3

6| - 15 Ar - |4

49

66

31

0.36

1.1

6| - 15 Ar - |6

49

66

33

0.38

1.1

6| - 16 Ar 90% - |4

49

66

31

0.36

1.1

6| - 16 Ar 90% - |4

35

74

25

0.29

1.1

8|

52

65

40

0.46

4.1

The data are calculated using spectral measurements that are conform to standards EN 410, ISO 9050 (1990)
and WIS/WINDAT.
The Ug-value (formerly k-value) is calculated according to standard EN 673. The emissivity measurement
complies with standards EN 673 (Annex A) and EN 12898.
This document is no evaluation of the risk of glass breakage due to thermal stress. For tempered glass: the risk
of spontaneous breakage due to Nickel-Sulfide is not covered by AGC Glass Europe. The Heat Soak Test is
available on request.
Specifications, technical and other data are based on information available at the time of preparation of this
document and are subject to change without notice. AGC Glass Europe can not be held responsible for any
deviation between the data introduced and the conditions on site. This document is only informative, in no way
it implies an acceptance of the order by AGC Glass Europe.
See also conditions of use.