Sei sulla pagina 1di 59

OptiX OSN

1500/2500/3500/7500/
9500 Equipment
Commissioning
www.huawei.com

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.

PDF created with pdfFactory Pro trial version www.pdffactory.com

Objectives
l

Upon completion of this course, you will be able to:


p

Successfully complete hardware and software commissioning of


OptiX OSN 1500/2500/3500/7500/9500 equipment

Interconnect all the equipment and perform system commissioning

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page1

Contents
1. Preparations before Commissioning
2. Single Station Commissioning
3. Network Commissioning

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page2

Preparations
l

Requirements to Commissioning Engineers


p

Be familiar with the fundamentals of SDH, PDH, Ethernet, and


ATM

Be familiar with the OptiX OSN equipment

Be familiar with the T2000,T2000LCT

Skillful with test instruments

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page3

Preparations (Cont.)
l

Prerequisites
p

Prepare tools and instruments


n

Understand engineering information


n

Laptop, Multi-meter, Optical power meter, Optical Attenuator, SDH Analyser,


Loop back patch fibre, DDF test cable, etc.

Networking, services, fiber and cable connection, clock tracing etc.

Confirm surrounding assets


n

Checking Installation of NMS

Checking Hardware Installation


OptiX equipment and DDF, ODF, EDF
Power Supply and Protection Ground

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page4

Contents
1. Preparations before Commissioning
2. Single Station Commissioning
3. Network Commissioning

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page5

Single Station Commissioning


Item

Sub-item
Checking hardware
Testing power-on of the cabinet

Single station
commissioning

Testing subrack functions


Configuring the commissioning data, and testing
the all buses
Testing the ALMC/RESET Button on the SCC

Testing the indices of optical/electrical interface


Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.
PDF created with pdfFactory Pro trial version www.pdffactory.com

Page6

Single Station Commissioning (Cont.)


Item

Sub-item
Testing on/off of all electrical interfaces
Testing the fiber jumper connection
Testing TPS

Single station

Testing active/standby board switching

commissioning Testing PDH channels in Series and monitoring


alarms and performance events
Testing intra-station ECC
Testing NE restarting after power failure
Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.
PDF created with pdfFactory Pro trial version www.pdffactory.com

Page7

Checking Hardware (Cont.)


l

Checking cabinet
p

Installation of cabinets must comply with the requirements of the


construction drawing

Multiple cabinets must be aligned, leveled and firmly fixed

All cabinets must be labelled

Power supply cables must be correctly connected (RTN+, NEG-)

Ground cable must be correctly connected to the Ground stud

Ground wires to the door must also be well connected

The Orderwire phone and ESD wrist strap are in place

No unrelated materials inside

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page8

Checking Hardware (Cont.)


l

Checking sub-rack
p

Power supply cables must be correctly connected to the right


connectors (PIU 1, PIU 2)

Ground wires to the sub-rack must be well connected

The vacant slots are installed with blank panels

Confirm available boards

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page9

Checking Hardware (Cont.)


l

Checking cables
p

Ethernet cable, PDH cables

Optical fibers, STM-1e cables

Network clock synchronization cables

Cables are connected, bundled and arranged neatly

All cables must be correctly labeled

The power cables and grounding cables outside the cabinet are
arranged separately from the signal cables

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page10

Checking Hardware (Cont.)


l

The AUX/EOW Board of OSN 1500

The SEI Board of OSN 2500

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page11

Checking Hardware (Cont.)


l

The AUX Board of OSN 3500

AUX

EOW

STAT

STAT
C
LK
I1

C
LK
I3

C
LK
O
1

C
LK
O
3

STAT
CLKO1
CLK4

CLKI1

CLK2

CLKO2
EXT

REV

CLKI2

PHONE

F&f

CLK1

CLK2

REV

ETH

F&f

COM

LAMP1

F1

EXT

LAMP2

OAM

ALMO1

S1

F1

PHONE

LAMP1

V1

LAMP2

V2

ALMO1

OAM

ALMO2

V1

V2

S2

ALMO2

S3
ALMI1

S4
ALMI2

COM

ALMI3

S1

ALMI1

S2

ALMI2

S3

ALMI3

S4

ALMI4

ETH
ALMI4

AUX

The AUX/EOW Board of OSN 7500

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

EOW

Page12

Checking Hardware (Cont.)


l

Checking Jumper J9 Setting on the AUX


Board for OSN 3500
p

Connected with a jumper cap: the main subrack

If not: an extended one

Power module

J9

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page13

Checking Hardware (Cont.)


l

Checking Jumpers Setting for Power Supply


Monitoring
p

Jumpers J9, J10 on OptiX OSN 2500 SAP


n

-48V: capped J9 and J10 (default)

-60V: remove the caps from J9 and J10

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page14

Checking Hardware (Cont.)


l

Checking Jumpers Setting for Power Supply Monitoring

Equipment

Jumpers on

Description

GSCC
OptiX OSN

J16, J17 on

3500

N1GSCC

OptiX OSN

J30 and J31 on

3500/7500

N3GSCC

OptiX OSN

J30 and J31 on

7500

N2GSCC

-48V: capped
(default)
-60V: remove the
caps from jumpers

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page15

Checking Hardware (Cont.)


1

3
2
O UT P UT

3 4

ON

3
2
O UT P UT

ON
R T N 1 (+) R T N 2 (+) N EG 1 (-) N EG 2(-)

O FF

IN P U T
3 2A

32A

20A

O FF
32A

2 0A

32A

2 0A

20A

1. Grounding stud

2. PGND

3. RTN1 (+)

4. RTN2 (+)

5. NEG1 (-)

6. NEG2 (-)

7. Left output cable terminal

8. Right output cable terminal

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page16

Checking Hardware (Cont.)


l

Checking Resistance Between Power Cable Posts


p

No connection with the power supply equipment

Action

The resistance between NEG1/2 () and


RTN1/2 (+) /PGND

All power switches

OFF
Subrack

> 20 K. If <20 , short circuit present and

power switches ON

remove the fault before continue

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page17

Checking Hardware (Cont.)


l

Checking Fuse Capacity of Power Output Terminal


Equipment

OSN 1500A

OSN 1500B

OSN 2500

OSN 3500
OSN 7500

Subrack type

The maximum power consumption


of a single sub-rack W

Fuse capacity

Common

200

10

Enhanced

313

15

Common

280

10

Enhanced

400

15

Common

400

15

Enhanced

643

25

Common

600

20

Enhanced

1088

32

Common

1000

32

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page18

Testing Power-on of the Cabinet


l

Testing method
Connect OSN equipment to the power equipment

Ensure that the positive and negative poles are not connected reversely

Measure the voltage of the power supply equipment at the top of the
cabinet
n

Ranging from 38.4 V to 57.6 V (-48V20%)

Ranging from 48 V to 72 V (-60V20%)

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page19

Testing Power-on of the Subrack


l

Testing method
p

Check the connection between sub-rack power cables and PIU boards

Turn on the left switches, and every sub-rack can be powered on normally

Turn off the left switches and turn on the right switches, and every
sub-rack can be powered on normally

Turn on all switches

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page20

Testing Sub-rack Functions


l

Testing the Fan


p

The green indicator is on, and you can feel wind blowing normally

The PWRA and PWRB indicators should be green

Testing the indicators on the top of the cabinet


Indicator

Power indicator (green)


Critical alarm indicator (red)
Major alarm indicator (orange)
Minor alarm indicator (yellow)

Status

Description

On

The cabinet is powered on.

Off

The cabinet is not powered on.

On

There is a critical alarm.

Off

There is no critical alarm.

On

There is a major alarm.

Off

There is no major alarm.

On

There is a minor alarm.

Off

There is no minor alarm.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page21

Testing the indicators on boards


l

The indicators on boards should be in the right status


Indicator status description
Indicator

Status

Description

On, green

The board works normally.

STAT (red or

On, red

The board hardware is faulty.

green)

Flash, red

The board hardware is mismatched.

Off

The board is not powered on, or the service is not configured.

On, green

Upload of board software to FLASH or the FPGA upload is normal, or


the board software initialization is normal.

On for 100ms and off for


100ms alternatively, green

Board software is being uploaded to FLASH or FGPA.

On for 300ms and off for


300ms alternatively, green

The board software is initializing, and is in BIOS boot stage.

On, red

The board software in FLASH or the FPGA configuration is lost,


resulting in upload and initialization failure.

Off

No power supply.

PROG (red
or green)

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page22

Testing Ethernet Ports


l

The location of Ethernet Ports


p

OSN 1500/ 3500: AUX Board

OSN 2500: SAP Board

OSN 7500: EOW Board

Testing method
p

NM port (ETH): 129.9.0.X

Usually, the cross-over network cable are applicable.

Check LED status on the ETH port

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page23

Testing Ethernet Ports (Cont.)


Indicator
LINK1
(green)

ACT1

Status

Description

On

The link between the first GE port and the opposite equipment is established.

Off

Flashing

(orange)
Off

The link between the first GE port and the opposite equipment is not
established.
There are data being exchanged between the first GE port and the opposite
equipment.
There is no data being exchanged between the first GE port and the opposite
equipment.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page24

Configuring Commissioning Data


l

Setting NE ID

Setting NE IP address and gateway IP, if need


p

Note: SCC will reboot automatically

Delivering Commissioning Data


p

Make configured services run through all boards and buses


n

All ports of all tributary boards

All buses of each line board

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page25

Configuring Commissioning Data (Cont.)


l

Distribution of average services


Service level

Service source

Service sink

VC12

2-PQ1-12

7-SL16-1-1-12

VC12

7-SL16-1-1-12

2-PQ1-12

VC12

VC12

2-PQ1-3132

7-SL16-1-16-12

VC12

7-SL16-1-16-12

2-PQ1-3132

VC12

2-PQ1-3334

12-SL16-1-1-12

VC12

12-SL16-1-1-12

2-PQ1-3334

VC12

VC12

2-PQ1-63

12-SL16-1-16-1

VC12

12-SL16-1-16-1

2-PQ1-63

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page26

Testing the ALMC Button on the SCC


l

Testing method
p

Remove the input fiber jumper, then the buzzer is triggered

Cut off the alarm sound temporarily


n

Press it in a short time, then the alarm sound disappeared.

Cut off the alarm sound permanently


n

Press it for more than 3 seconds

The ALMC indicator turns yellow

Reconnect the fiber jumper, then remove it again

The buzzer will not beep

Cancel the permanent cut-off status after the test

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page27

Testing the RESET Button on SCC


l

Testing method
p

Press the RESET button to reset the SCC board.

The SCC will reset after two minutes.

The NE can be logged in and is in the running state again.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page28

Testing the Centralized Alarm System


l

Testing method
p

Check the cable and connection for the alarm output cable.

Remove the input fiber jumper, the buzzer will beep.

The centralized alarm processing device will give corresponding


audible and visual indications.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page29

Testing On/Off of All Electrical


Interfaces
l

Testing method
p

Connect BER tester on DDF


n

Outloop: normal service

Inloop: interrupted service

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page30

Testing the Fiber Jumper Distribution


l

Testing method
p

On ODF, test the transmitting fiber


n

Connect the fiber jumper: normal

Remove the fiber jumper: loss

Loopback the optical port on ODF


n

Close the laser, R-LOS occurs

Open the laser, R-LOS ends

Check the fiber label

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page31

Testing Optical/Electrical Interface Indices


Test item

Description

Mean launched power

Mandatory

Actual received optical power

Mandatory

Receiver sensitivity

Optional

Allowable input frequency deviation at the optical interface

Optional

Input jitter tolerance at the optical interface

Optional

Output jitter at the optical interface

Optional

Allowable input frequency deviation at the electrical interface

Optional

Input jitter tolerance at the electrical interface

Optional

Output jitter at the electrical interface

Optional

Fiber
jumper

Optical
interface
board

Tested
optical
interface

Optical
interface
board

Fiber
jumper
-

ODF

ODF

OUT

Fiber
jumper

Tested
optical
interface

OUT
IN

Optical
power meter

IN
Local station

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Adjacent

Page32

station

Testing TPS Function


Step
1

Action
Configure TPS protection. Suppose that the PQ1 board in slot 1 protects the PQ1 board in slots 2 (with low priority) and 3
(with high priority).

Check the status of TPS protection and the ACT indicators on PQ1 boards.

Self-loop the optical interface with a 5 dB attenuator.

Connect BER tester to E1 port of the D75S board. The BER tester gives no alarm.

Remove the PQ1 in slot 2. Services are interrupted transiently and resumed immediately.

Check TPS protection switching status and the ACT indicator.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page33

Testing TPS Function (Cont.)


Step

Action

Remove the PQ1 in slot 3. The BER tester generates an alarm.

Connect the BER tester to protected service interface. The BER tester will be normal.

Insert the working board in slot 3 back to test restoration. Check TPS protection switching status and ACT indicator.

10

Verify that the switching state of the protected board is WTR.

11
12
13

After the WTR time, the PQ1 board in slot 3 should work. And the PQ1 board in slot 1 should also work to protect the PQ1
in slot 2.
Insert the working board in slot 2 back to test restoration. Check TPS protection switching status and ACT indicator.
Verify that the switching state of the protected board is WTR. After the WTR time, the PQ1 board in slot 2 should restore
to work.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page34

Test Active/Standby XCS


l

Testing method
Configure boards and services
p Self-loop the optical port on DDF, and connect BER tester
p Switch test
p

Implement XCS switch (3 methods)

n
n
n

Issuing switch command by T2000


Hard reset active board by T2000
Pull out active board (jiggle switch)

ACT indicator
1+1 XCS protection status
VC4 services and clock should be good,VC12/VC3 services are
momentarily interrupted.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page35

Test Active/Standby XCS (Cont.)


p

Restore test
n
n
n
n

Restore the 1+1 XCS protection through T2000


ACT indicator
1+1 XCS protection status
VC4 services and clock should be good,VC12/VC3 services are
momentarily interrupted.

Notes

The interval of active/standby switch should be done after at least 1 min.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page36

Testing Active/Standby GSCC


l

Test method
p

Configure boards and services

Connect BER tester

Switch test
n

Implement GSCC switch (3 methods):

Issuing switch command by T2000

Hard reset active board by T2000

Pull out active board (jiggle switch)

Services should be normal

NE can be logged in again

The consistent configuration on the GSCC and T2000

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page37

Testing Active/Standby GSCC (Cont.)


p

Restore test
n
n
n
n
n
n

Restore the 1+1 GSCC protection through T2000


ACT indicator
1+1 GSCC protection status
Services should be normal
NE can be logged in again
The consistent configuration on the GSCC and T2000

Notes

The interval of active/standby switch should be done after at least 1 min.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page38

Testing Active/Standby CXL1/4/16


l

Attention to CXL1/4/16 switch


p

CXL1/4/16 = SCC + Cross Connection + Clock + LU

SCC Unit and Cross Connection Unit switch together

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page39

Testing PDH Channels in Series


l

Testing method
p

At the ODF side, selfloop the optical ports.

Connect the test meter to service ports.

Test 15 minutes, and no any alarm and


bit error
DDF
BER tester

RX TX
1
2
3

RX TX

.
..
.

60
61
62
63

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page40

Ending NE Commissioning
l

Final Work to Do
p

Test the Intra-Station ECC

Single station power off test (for 10 minutes)

What else?
n

ALMCUT is correctly set.

Order wire handset switch is ON, "TALK" button is off.

All hardware and software loop backs are removed.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page41

Contents
1. Preparations before Commissioning
2. Single Station Commissioning
3. Network Commissioning

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page42

Network Commissioning
Item

Sub-item
Checking actual received optical power and network-wide fiber connection
Configuration network
Testing ECC
Testing service channel availability

Network
commissioning

Testing self-healing protection switching


Testing clock protection switching
Testing the Orderwire
Testing network-wide BER
Testing other indices
Verifying the NMS functions

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page43

Testing the Received Optical Power


l

Testing the Actual Received Optical Power


p

Check if the received optical power has been tested in the single

station commissioning.
p

Receiver sensitivity +3dB <Received power <Overload power 5dB

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page44

Checking Network-Wide Fiber Connection


l

Checking Fiber Jumper Connection and Labeling


p

According to topology, check fiber connection

Checking fibre jumper labelling

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page45

Checking Connection of an NM
Computer to the Equipment
l

Two types of connection


p

Direct connection

Connection through a LAN

The indicator status


p

The green LINK indicator must stay lit.

The orange ACT indicator must flash.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page46

Configuration Network
Step

Action

Logging in the T2000

Creating and configure NEs

Creating boards

Creating fibers

Creating a topology subnet

Creating a protection subnet

Configuring clock

Creating SDH/PDH services

Creating Ethernet services

10

Configuring board level protection

11

Configuring the Orderwire

13

Setting performance parameters

14

Setting alarm parameters

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page47

Testing ECC
l

NE login test
p

ECC automatic routing test


p

By default, the short ECC route is used.

Single-route ECC test


p

The single-route ECC route is available, if cut off the other fibers.

Test another direction

ECC pass-through test


p

All NEs can be logged in

Pull out SCC board in ADM NE, and other NEs can be logged in.

Extended ECC test

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page48

Testing Service Channel Availability


l

Testing Electrical/Optical Interface Services


p

Normal testing
n

Interrupted testing
n

Loopback and perform bit error test for 10 minutes, and no bit errors or alarms
Release the loopback, and AIS alarm generates.

Use the same method to test other channels


BER tester

NE4

NE1

STM-16
non- protection
chain
NE2
STM-64 two-fiber
bidirectional MSP Ring
loopback

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page49

NE3

Testing Service Channel Availability


l

Testing Ethernet Services


p

Testing Through a Laptop Computer


n

EPL/EPLAN
Computer A

Testing Through a Data Analyzer


n

EPL/EVPL/EPLAN/EVPLAN

NE1

Computer B
NE4

NE2

STM-64 two-fiber
bidirectional MSP
ring

NE3

STM-16 two-fiber
bidirectional nonprotection chain
VCTRUNK

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page50

Testing Self-Healing Protection


l

Two-fiber bidirectional MSP ring


p

Query the switch status upon normal optical paths: IDLE

Connect the tester, loopback the service port of the other end.

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page51

Testing Self-Healing Protection (Cont.)


l

Two-fiber bidirectional MSP ring


p

Test switching by removing fibers or shutting down the laser.


n

Proper switch status

Switch completion in 50ms

Proper alarms or performance are reported

Services can be protected

Test restoration

Test MSP switch for each section repeatedly

Test MSP switch when powering OFF

Test other external switch functions

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page52

Testing Self-Healing Protection (Cont.)


l

Four-fiber bidirectional MSP ring


p

Test the span switch

Test the ring switch

1+1 and 1:N linear MSP


p

Test switch of each section in turn

Dual-End Switching and Single-End Switching

Revertive and non-revertive mode

SNCP
p

Delay time = 0

Revertive and non-revertive mode

Test switch of each section in turn

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page53

Testing Clock Protection and Orderwire


l

Testing Clock Protection Switching


p

Switch and restoration

Testing Orderwire
p

Testing the Addressing Call

Testing the Conference Call

Testing Orderwire Functions by Removing Fibers in the ring

Testing Orderwire upon Orderwire Pass-through

Testing Subnet Outgoing Orderwire

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page54

Testing Network-wide BER


l

Connect SDH analyzer to 2~6 E1 interfaces in series


p

Testing 24-hour BER in the Active Channel

Testing 12-hour BER in the Standby Channel

Monitor alarms and performance events of 15m and 24h through NMS

No abnormal alarms

No error

Less than 6 times pointer adjustment counts

SDH analyzer
n
n

NE

Grounding

NE

Set with the print status

Control the testing area

SDH analyzer

NE

NE
Loop-back
PDH Port

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page55

Other Testing Items


l

Test other indices


p

Jitter, frequency deviation

NM function verification

Remote maintenance function verification

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page56

Network Commissioning (Cont.)


l

Questions
p

During commissioning, which steps are important?


Item

Preparations before
Commissioning

Sub-item
Grasp basic skill
Understand engineering information
Checking Resistance Between Power Cable Posts
Delivering Commissioning Data
Testing optical/electrical interface indices

Single station
commissioning

Testing the on/off of all electrical interfaces


Testing the fiber jumper connection
Testing TPS and active/standby board switching
Testing buses in series
Network-wide configuration

Network commissioning

Checking network-wide fiber connection and actual received optical power


Testing ECC, service make/break and protection switching
Testing network-wide BER

Copyright 2008 Huawei Technologies Co., Ltd. All rights reserved.


PDF created with pdfFactory Pro trial version www.pdffactory.com

Page57

Thank you
www.huawei.com

PDF created with pdfFactory Pro trial version www.pdffactory.com