Sei sulla pagina 1di 15

( Reaffirmed 1998 )

IS I 771 ( Part 2 ) - 1985

Indian Standard
SPECIFICATION FOR
GLAZED FIRE-CLAY SANITARY APPLIANCES
PART

SPECIFIC REQUIREMENTS
OF KITCHEN
AND LABORATORY
SINKS

( Third Revision)
Sanitary

Appliances

and Water

Fittings

Sectional

Committee,

BDC 3

Reprcsrnlin6

Chairman

Municipal
Corporation
Bombay

Srrnr K. D. MUL~KAR

of

Greater

Bombay,

Membera
&
Environmental
Central
Public
Health
Engineering Organization ( Ministry of Works
& Housing ), New Delhi
DEPUTY ADVISER ( PHE ) ( Altcrnatr )
M/s Goverdhan Das P. A. ( Calcutta ), Calcutta
SHRI J. R. Aoonawax.
National Test House, Calcutta
SERI S. K. BANERJEE
SHRI D. K. KANUN~O ( Al&mate )
Central Glass & Ceramic
Research
Institute
SERI M. K. BASU
(CSIR ), Calcutta
Uttar Pradesh Jal Nigam, Lucknow
CHIEF EN~INEEB
SUPEBINTENDINGENGINEER ( Alter;;;;c)
Department,
Health
Engineering
CHIEF ENGINEER
Trivandrum
SHRI K. RAMACHANDRAN (Alternate )
Delhi Municipal Corporation, Delhi
&IRI .T. DCRUZ
S&x s. A. SWAMY ( Alternate )
Engineer-in-Chiefs
Branch, Army Headquarters,
SHRI B. R. N. GUPTA
New Delhi
SHRI K. V. KRISHNAMURTHY ( Alternate )
Municipal
Corporation
of Greater
Bombay,
HYDRAULIO ENGINEER
Bombay
DEPUTY HYDRAULIO ENGINEER ( Allernate )
ADVISEB

( Continuedon page 2 )

INDIAN

Q C@yri&
STANDARDS

1986
INSTITUTION

This publication
is protected under the Indian Copyright Act ( XIV of 1957) and
reproduction in whole or in part by any means except with written permission of the
publisher shall be deemed to be an infringement of copyright under the said Act.

IS : 771 ( Part 2 ) - 1985


( Conlinurdfrom

page 1 )

Membrrs

Repr#renting

SHRI S. R. KSHIH~AGAH

National
Environmental
Engineering Research
Institute (. CSIR II
1. Naeour
A
&RI A. W. DESEPANDE ( Allnaate )
SHRI K. LAXBHMINARAYANAN
Hindustan Shipyard Ltd, Vishakhapatnam
SERI A. SHAKIFF ( Alternate )
National Buildings Organization, New Delhi
DR A. V. R. RAO
SHRI.J. SENOUPTA ( Alt~matr )
E.I.D. Parry ( India ) Limited, Madras
Sunr A. K. SARKAK
SHRI M. DO~AISWAMY ( Alternate )
Leader Engineering Works, .Jalandhar
SHRI D. K. SEH~AL
SHRI B. B. SIRKA ( Altcrnatc )
Mini;styhiof
Railways
(
Railway
Board ), New
SENIOR CIVIL ENQXNEEH ( WATER
SUPPLY )
Cent;raoryeEding
Research
Institute ( CSIR ),
SH~I S. K. SHARMA
Maharashtra Water Supply & Sewerage Board,
New Bombav
Hindustan Sanitiryware
& Industries Limited,
Bahadurgarh ( Haryana )
Central Public Works Department, New Delhi

SHRI M. N. SHEWADE

SHRI R. K. SOMANY

SUPERINTENDING SURVEYOB OF
WORKS ( ND2 3
SURVEYOK OF WORKS I ( NDZ ) ( Altcrnats )
Directorate Grneral of Technical Development,
SHRI R. THANJAN
NFW Delhi
SHRI M. M. ALIKHAN (Alternate \
Directorate Grncral of Supplier & Disposals, New
SHRI T. N. UBOVEJA
Delhi
Director General, ISI ( ,%&$cia M.mbcr )
SRRI G. RAMAN,
.Director ( Civ Engg ).
Secretary

SHRI K. K. SHARMA
Joint Director ( Civ Engg ), IS1

Domestic Sanitary Appliances and Accessories Subcommittee,


Engineer-in-Chiefs
New Delhi

SELRIB. R. N. GUPTA

Branch, Army

BDC 3 : 1
Headquarters,

Members

&tar V. ANANTHANARAYAIAN
SHRI M. K. BASV
CHIEF ENCXNEEX
CHIEF EN~INEEB ( S~WESAOE )
DBPUTY
CHIEF
( SEWE~AUE ) (

EN~~EBR

East India Ceramics, Veilore


Central Glass &, Ceramic
( CSIR ), Calcutta
Tamtayr;u
Water Supply
Municipal
Corporation
Bombay

of

Research

Institute

& Drainage
Greater

Board,

Bombay,

A~tcrnata
)
( Cmtinucd en psga 8 )

IS:771

(Part2)-1985

Indian Standard
SPECIFICATION FQR
GLAZED FIRE-CLAY SANITARY APPLIANCES
PART 2 SPECIFIC REQUIREMENTS OF KITCHEN
AND LABORATORY SINKS

( Third Revision )
0. FOREWORD
0.1 This Indian Standard ( Part 2 ) ( Third Revision ) was adopted by
the Indian Standards Institution on 31 July 1985, after the draft finalized
by the Sanitary Appliances and Water Fittings Sectional Committee had
been approved by the Civil Engineering Division Council.
0.2 This standard was first published in 1958 and subsequently revised in
1963 and 1979. The third revision of this standard has been taken up to
incorporate further modifications necessary in the light of the comments
received.
The modifications include additional clauses on thickness of
sinks and requirements of rim and base portion of the appliances.
The
requirements
applicable
to all appliances
and specific
general
requirements for different types of appliances have been covered in
This standard ( Part 2 ) lays down the
separate parts of the standard.
specific requirements of glazed fire-clay kitchen and laboratory sinks.
0.3 In the formulation of this standard due weightage has been given to
international coordination among the standards and, practices prevailing
in different countries in addition to relating it to the practices in the field
in this country.
0.4 For the purpose of deciding whether a particular requirement of this
standard is complied with, the final value, observed or calculated,
expressing the result of a test or analysis, shall be rounded off in
accordance with IS : 2-l 960*.
The number of significant places retained
in the rounded off value should be the same as that of the specified value
in this standard.
1. SCOPE
1.1 This standard ( Part 2 ) lays down the pattern and sizes, construction,
dimensions and tolerances of kitchen and laboratory sinks made of
fire-clay.
*Rules

for rounding

off numerical

values

(m&d).

49 : 771 ( part

2 ) _ ~985

2. REQUIREMENTS
2.1 General - The general
requirements
for material,
manufacture,
methods of test, and inspection shall conform to IS : 771 ( Part 1 )-1979*.
2.2 P&ttewms, f&es ad
H&ding
Capacities
- Sinks shall be suitable
Jar kitchen or laboratory
( see Fig. 1 ) and shall be made in the following
sizes and hofding capacities:
Pattern

a) Kitchen

Lsizcs
mm

sinks

b) Laboratory

sinks

+------A
IF

Holding Capacities
( Litres ), Min
r---h
___~
Without
Ovsrllow

With
Overflow

750 x 450 x 250


600 x 450 x 250
600 x 450 x 200

51
42
32

42
36
26

con
500
450
400

30
16.5
12.5
9

25
14
11
8

x
x
x
x

400
350
300
250

x
x
x
x

200
150
150
150

,=qTRIM

FIG. 1

PROJECl,tON (OPTIONAL)

KITCHEN AND LABORATORY

*Specification for glazed fire-clay sanitary appliances:

( secondrroision ) .

SINKS

Part 1 General

requirements

IS : 771 ( Part
2.2.1 The dimensions mentioned
portions of the appliance.

in 2.2 shall be applicable

2) - 1985

to the rim

2.2.2 The kitchen and laboratory sinks may be made in other patterns
and sizes where so agreed to between the manufacturer
and the
purchaser.
However, tolerances on dimensions shall be as specified in
this standard.
2.3 Construction
2.3.1 Kitchen Sinks - The
kitchen
sinks
construction with or without rim and with or
The slot type overflow shall have a minimum
be SO designed as to facilitate cleaning of the
overflow, where provided, shall be minimum

shall be of one
piece
without combined overflow.
area of 1 100 mm2 and shall
overflow. The invert of the
30 mm below the top edge.

23.1.1 The sinks shall have a circular waste hole into which the
interior of the sinks shall drain.
The waste hole shall be rebated or
beveiled internally (see Fig. 2 ) with an overall diameter of 90 mm and a
depth of 10 mm to suit a waste fitting having a flange of 88 mm
diameter.

BEVELLED
WASTEHOLE

All dimensionsin millimetres.

FIG. 2

DETAILS OF WASTE HOLES FOR KITCHEN AND


LABORATORY SINKS

sinks shall be of one piece


2.3.2 Laboratory Sinks - The laboratory
construction with or without rim and with or .without combined overflow.
The invert of the overflow where provided shall be minimum 30 mm
below the top-edge. The overflow shall be similar to that in kitchen sink
( see 2.3.1 ).
2.3.2.1 The sinks shall have a circular waste hole into which the
The waste hole shall be either rebated
interior of the sinks shall drain.
or bevelled with an overall diameter of 65 mm and a depth of 10 mm to
suit a waste fitting having a flange of 64 mm diameter.
5

IS : 771 ( Part 2 ) - 1985


2.4 Dimcndors

and Tolerances

sinks shall conform


2.4.1 Dimensions - Kitchen sinks and laboratory
the dimensions
given in Table 1 read with Fig. 1.
TABLE

DIMENSIONS

OF KITCHEN

AND

LABORATORY

to

SINKS

( Clauses 2.4.1 and Fig. 1 )


All dimensions

in millimetres.

(8)

(9)

(10)

30

75

90 + 3
-0

65 + 3
-0

150

30

75

90 + 3
-0

65 + 3
-0

200

150

30

75

90 + 3
-0

65 + 3
-0

400

200

90

30

75

65 + 3
-0

45 + 3
-0

500

350

150

go

30

75

65 + 3
-0

45 + 3
-0

450 x 300 x 150

450

300

150

90

30

75

65 + 3
-0

45 + 3
-0

400~250~150

400

250

150

90

30

75

65+3
-0

45+3
-0

SIZE

DEF

(2)

(3)

(4)

(5)

(6)

(7)

750 x 450 x 250

750

450

250

150

600 x 450 x 250

600

450

250

600 x 450 x 200

500

400

600 x 400 x 200

600

500 x 350 x 150

PATTERN

(1)
a) Kitchen sinks

b) Laboratory
sinks

2.4.2 Tolerances dimensions


specified

Min Min

The following tolerances shall be permissible


for kitchen and laboratory
sinks:

a) On dimensions

of 50 mm and over f 4 percent;

b) On dimensions

less than

on the

and

50 mm f 2 mm.

thickness of the walls and bottom of


2.4.3 Thickness - The minimum
the sinks of sizes mentioned
in 2.2(a) and 2.2(b) shall not be less thorn
25 mm and 15 mm, respectively.
2.4.3.1 Wherever
integral
overflow
arrangement
is provided,
thickness of the overflow wall shall not bc less than 12 mm.
6

the

IS : 771 ( Part

2 ) - 1985

3. MARKING
3.1 Sinks shall be clearly and indelibly marked at a prominent
visible after the sinks are installed, with the name or trade-mark
manufacturer.

place,
of the

3.1.1 Each sink conforming to the requirements


specified in
standard may also be marked with the IS1 Certification Mark.

this

NOTE- The use of the IS1 Certification Mark is governed by the provisions of
the Indian Standards Institution
(Certification
Marks ) Act and the Rules and
Regulations made thereunder.
The IS1 Mark on products covered by an Indian
Standard conveys the assurance that they have been produced to comply with the
requirements of that standard under a well-defined system of inspection, testing and
quality control which is devised and supervised by IS1 and operated by the producer.
IS1 marked products are also continuously checked by IS1 for conformity to that
standard as a further safeguard.
Details of conditions under which a licence for .thc
use of the IS1 Certification Mark may be granted to manufacturersor
processors,
may be obtained from the Indian Standards Institution.

4. SAMPLING
4.1 The sampling shall be done in accordance

*Method

of sampling ofvltrcous

with IS : 914X)-1985*.

and fireaclay aanitacy appliances


7

(Jirsf reaision).

IS : 771 ( Part i ) - 1985


(Continued from page 2 )
Members

Repenting

Municipal Corporation of Delhi Delhi


SHBI J. D Canz
SHRI S. S. RAMRAKHYANI ( AIternare )
Research,
Designs & Standards
Organization
DIEPUTT DIREOTOB ( AROH )
( Ministry of Railways ), Lucknow
ASSISTANT DIBECTOR ( ARCH ) ( Altarnate )
Parshuram Pottery Works Co Ltd, Thangadh
SH~I A. A. GANPULE
SHBI RAJENDRA KUMAR (Alternate )
Department,
Public
Health
Engineering
SHRI S. P. JAMS
Trivandrum
.%a~ K. RAXAOEANDRAN ( Alternate 1
Madhusudan Ceramics, Ahmadabad
SHILI B. D. KOTEARI
SH~I V. S. BHATT ( Alternate )
Engineer-in-Chiefs
Branch, Army Headquarters,
SEILI K. V. K~ISHNAMURTHY
New Delhi
Indian Plastics Limited, Bombay
S-1 K. V. KBISENAW
SEBI M. L. ANAND
( Alfcmolc )
Roplas ( India ) Limited, Pune
SEEI J. LAKHA~I
SHRI E.D. SEARMA
(Alternate)
In personal capacity ( 9 Jain Mandir Road, New
SHBX B. K. MALEAN
Delhi )
Phenoweld Polymer Pvt Ltd, Bombay
SERI B. S. MIRCEAN~ANI
SHRI P. R. GUPTA ( Alferuate )
E. I. D. Parry ( India) Limited, Madras
SHRI A. K_. SARKAR
1,
SHRI M. DORAISWAMY ( Alternare)
Neivcli Ceramics & Refractories Ltd, Vadalur
SHRI UMATOSH SARKAR
M/s Sehgal & Co, New Delhi
SHRI L. R. SEEQAL
National Buildings Organization, New Delhi
SHRI J. SENQDPTA
SHRI 0. P. RATRA (Alternate)
Centr$o,e$ling
Research
Institute
(CSIR ),
Sasr S. K. SAARMA
Sam R. K. SOMANY

Hindustan
Sanitaryware
&
Industries
Ltd,
Bahadurgarh ( Haryana )
Central Public Works Department, New Delhi

SQPERINTENDINQ SURVEYOR OF
WORKS ( SWZ )
SURVEYOR OF WORKS ( NDZ ) ( Alternate )
FGP Ltd, New Delhi
SEBI G. K. TAXIER
Soar S. M. DASTUR ( Afteraafe )
Directorate
General
Soar T. N. UBOVEJA
New Delhi

of

Supplies

& Disposals,

AMENDMENT NO. 1 DECEMBER 1995


TO
IS 771( Part 2 ) : 1985 SPECIFICATION FOR GLAZED
FIRE-CLAY SANITARY APPLIANCES
PART 2

SPECIFIC REQUIREMENTS OF KITCHEN AND


LABORATORY SINKS
( Third Revision)

( Pqe4,
i)

clause 2.2 ):

Substitute With Integral Overflow for With Overflow in the last


COhtUl.

ii) Substitute 9.5 for 42, 36, 26 against Kitchen sinks in the last
COlUltUL
f

Page 4, Fig. 1) - Substitute the following for the existing figure:

RIM PROJECT10

FIG. 1 KITCHENANDLABO~~RY

Srms

(Page 5, clause 2.2.1) - Delete.


(Page 5, clause 2.3.1) - Substitute the following for the existing:
23.1 Kitchen Sinks - The kitchen sinks shall be of one piece construction
with or without rim but without overflow.
(Page 5, clause 2.3.1.1) - Delete.
1

Amend No. 1 to IS 771( Part 2 ) : 1985

(Pages, Fig. 2 ) - Delete.


( Page 5, clause 2.3.2 ) (Page 5, &use 23.2.1)

Delete the last sentence.


-

Delete.

(Page 5, clause 2.3.2.1 ) -Add

the following matter after 2.3.2.1:

2.33 Waste Hole L The sir& shall have a circular waste hole ( see Fig. 2 )
through which liquid content of the sink shall drain. The base of the sink shall
have proper and sufficient slope to drain the liquid content into the waste hole.
The waste hole shall be bevelled internally and shall meet the dimensions given
in? able 1.

FIG. 2 DETAILS
OF WASTE HOLFS FOR
KITCHEN
AND

TABLE
SL No.

DIMENSIONS

OF WASTE
REFMFYGURE

PARTICULARS

LABORATORY

HOLE
DIMENSIONSw MM

Diameter of outer opening

d,

46, +2/-3

ii)

Outside dimensions for seating the


outlet cock, with angle loo,to/-5

d4

65~2

ds

15 Max

1 Maximum diameter at the


111,

bmdkdportion of opening
iv)

Outside diameter of seating


face of the outer opening

da

60Min

v)

Depth

45 Min
50 Ma%

vi)

Distance between tbe


reference dia and the seating
sutke for the gasket

bt

SINKS

4OMin
4s Max

Amend No. 1 to IS 771( Part 2) : 1985


2.3.3.1 Sinks shall be provided with waste fittings conforming
requirements laid down in IS 2963 : 1979+.

to the

2.3.3.2 Where integral overflow is provided, the projection on account


overflow connection to the waste hole of the sink shall be over and above
dimension C. Where integral overflow is not provided, the projection at
outlet shall be not less than 15 mm. The dimension C shall be measured at
end opposite to waste hole, as shown in Fig. 1.

of
the
the
the

(Page 5, fool-nofe) - Add the following foot-note at the end:


*Copper alloy waste fittings for wash basins and sinks -Specification.

(Puge 6, clause 2.4.1, line 2 ) -

Substitute Table 2 for Table 1.

( Page 6, Table 1 ) - Renumber Table 1 as Table 2 and delete columns


7,8, 9 and 10. Against Kitchen sinks for size 600 x 450 x 200, in column 3
substitute 600 for 500 and in column 4 substitute 450 for 400.

(CED3)
Reprography
Unit, BIS, New Delhi. India

AMENUMENT

NO. 2 OCIOLSEI~ 1996


TO
FOR GLAZE3
IS 771 ( I:~I-12 ) : 1985 SIlKIIICAIION
l~IKl:-CLAY SANITARY AlILIANCIZS
PART

SPECIFIC

REQUIREMENTS

LABORATORY

OF KITCHEN

AND

SINKS

( Third Revision)

(CED3)
Reprography IJnit, HIS, New Delhi, India

AMENDMENT

NO. 3 DECEMBER
1998
TO
FOR GLAZED
IS 771( Part 2) : 1985 SPECIFICATION
FIRE-CLAY SANITARY APPLIANCES
PART

SPECIFIC REQUIREMENTS OF KITCHEN


AND LABORATORY SINKS
( Third Revision)

[ Page 4, clause 2.2 ( see also Amendments No. 1 and 2 ) ] Holding Capacities

Delete

along with their contents.

[ Page 6, Table 1 ( see aho Amenuhent No. 1 ) ] (vi) along with their contents.
( Page 2, Fig. 2, Amendmenr No. 1) -

Delete angle

too T t in both the figures.


( Page 3, clause 2.3.3.1, Amendment No. 1 ) the existing:
2.3.3.1 The waste hole shall accommodate
diameter of 64 mm (see IS 2963 : 1979).

Delete Sl No. (ii) and

Substitute

a waste

fitting,

tbe following
having

for

a flange

(CED3)

Rcproeraphy Unit, BIS, New Delhi, India