Sei sulla pagina 1di 2

MEDUMAT Standard2

A Clear New Perspective.


Key Features:
CPR mode
RSI mode
CPAP mode
Patient height setting
Optimized monitoring
Software options
Operator menu

Quick Overview:
Ideal screen layout
for the best overview...

Connection options on device front


for MEDUtrigger, measurement and
ventilation hoses

Lithium-ion removable battery


with battery life of six hours per charge

Storage & Updates


data storage and operator-managed
software updates with SD card

User-friendly operation
quick use of function keys for fast and
simple operation

Device inlet filter


to protect device

MEDUMAT Standard2
A Clear New Perspective.
Your benefits at a glance:
CPR mode assists operator in resuscitation compliant
with guidelines
Support with pre-hospital induction of
anesthesia provided by RSI mode
Non-invasive ventilation with CPAP mode
Quick and easy initiation of ventilation with setting for

patient height or with use of emergency modes


Optimized monitoring 5-inch TFT screen with
all relevant information
Device inlet filter protects device from contamination
Can be combined with MEDUCORE defibrillators
Flexibility ensured by software options

Device dimensions (W x H x D)

206 mm x 137 mm x 130 mm

Weight, including rechargeable battery

About 2.5 kg

Product class as per Directive 93/42 EEC:

IIb

Operating conditions:

Temperature range:
Humidity:
Air pressure:
Altitude above sea level:

-18 C to +50 C
0 % to 95 % relative humidity without condensation
540 hPa to 1100 hPa
- 500 m to 5000 m

Storage and transport:

Temperature range:
Humidity:

- 40 C to + 70 C (maximum 48h)
0 % to 95 % relative humidity without condensation

Rechargeable battery:

Operating time:
6 hours (depending on options and device)
Charging time (0% - 95%): 3.5 hours
Service life:
at least 300 charging cycles
Lithium-ion

Voltage:

Vehicular electrical system: 12 V - 15 V


Mains operation:
15 V

Display:

TFT color display:


Resolution:

Data storage:

SD card

Ventilation modes:

5-inch
320 pixels x 240 pixels

Volume-controlled:

IPPV, CPR, SIMV (optional), S-IPPV (optional),


RSI, inhalation (optional)
Pressure-controlled: CPAP

Inhalation:

0 l/min to 10 l/min, in 1 l/min increments

Operating gas:

Medical-grade oxygen

Operating pressure range:

2.7 bar to 6 bar

Maximum outlet flow:

At least 80 l/min at inlet pressure of 4.5 bar in Air Mix and in No Air Mix operation

I:E

1:1.7 mandatory, otherwise trigger-dependent ( 10 %)

Ventilation frequency:

5 min-1 to 50 min-1 ( 1 min-1)

Tidal volumes:

50 ml to 2000 ml ( 40 ml or 20 %)

Maximum pressure (Pmax):

10 mbar to 65 mbar ( 3 mbar or 15 %)

PEEP:

0 mbar to 20 mbar ( 3 mbar or 15 %)

Classification as per EN 60601-1:

Degree of protection against electric shock: Class II


Degree of protection BF

Standards used:

EN 60601-1, EN 1789, EN 794-3, ISO 10651-3, RTCA DO-160 G

weinmann-emergency.de | weinmann-emergency.fr | weinmann-emergency.ru | weinmann-emergency.cn

13-325-EN-08-2013 Copyright protected. Duplication of any kind only with the express permission of WEINMANN Emergency.
All rights to design and specification modifications reserved.

Technical Data MEDUMAT Standard 2