F L O W
M O N I T O R S
ROCON L.L.C.
Rocon Water
Control Valve
Improve robotic
weld quality and
extend equipment life
using Rocon Water
Control Valve
Rocon Water Control Valve (WCV)
prevents leaks and defective welds
in the resistance welding process.
This is done by shutting off the water
flow to a displaced weld cap. The
operator is then made aware of this
condition by an electrical signal and
optional LED lights. Features include:
Reduces downtime and costly
maintenance for cleanup upon
cap displacement
Alarms and shuts off water in
less than 1/2 a second
MECHANICAL
Pressure drop at 1 GPM
Maximum water flow:
Minimum water flow:
Maximum water temperature:
Minimum water temperature:
Maximum operating pressure supply:
Minimum operating pressure supply:
Maximum operating pressure return:
Minimum operating pressure return:
Maximum pressure differential:
Minimum pressure differential:
Manual restart - maximum pound force:
Air restart - air valve:
Air restart - maximum air pressure:
Air restart - minimum air pressure:
2 PSI
.5 - 3 GPM
.5 of a gallon
180F
35F
Port #1, 100 PSI
Port #1, 10 PSI
Port #4, 50 PSI
Port #4, 5 PSI
Port #1 and #4, 50 PSID*
Port #1 and #4, 5 PSID
100 pounds
2 position, 3 way, NC
100 PSI
NOTE: RETURN WATER
PRESSURE PORT #4 CANNOT
BE MORE THAN 15 PSI HIGHER
THAN AIR RESTART PRESSURE
13.8 kPA
2-12 LPM
2 LPM
82 C
1.7 C
68.9 kPA
68.9 kPA
344.7 kPA
34.5 kPA
344.7 kPA
34.5 kPA
45 Kg
11.5 lb
11.5 lb
5.2 Kg
5.2 Kg
ELECTRICAL
Three-wire switch:
Indicator lights:
AC - 120 V
Red / Green
Yellow
DC - 24V
Red / Green
Yellow
Air coil:
689 kPA
CONSTRUCTION MATERIALS
Housing:
Brass
Plastic parts:
Seals:
Air restart:
Switch box:
Anodized Aluminum
Remote restart/backflush
Window:
Lexan
Air lockout:
Latch, spring = SS
No orifice to clog
One size fits all (.5 - 3 GPM)
Low pressure drop (less
than 2 PSI at 1 GPM)
Operates anywhere, with
open or closed systems
How It Works
FLOW OUT
FLOW OUT
FLOW IN
FLOW IN
Weld
Tips
Sub-Plate Style
4.7
(119.4 mm)
6.5
(165 mm)
COOLING WATER
Shut Off
Switch Setting
Inadequate Flow
Operational
INDICATION
F L O W
M O N I T O R S
MODEL
NO.
ROCON
NO.
SERIAL
NO.
WARNING: This instrument was made for the specific use stated at
time of order. Any other use may cause injury. Read instructions
before using. U.S. and foreign patents pending.
INSTALLATION PORT CODE
SUBPLATE OR INLINE
Port
Function
1
WATER "IN"
2
WATER "TO GUN"
3
WATER FROM "GUN"
4
WATER "OUT"
5
AIR "IN"
8.1
(205.7 mm)
WATER FLOW = ON
AIR RESTART = ON
OR LOCKOUT = ON
WATER FLOW = FAULT
WATER / AIR PRESSURE LIMITS
SUPPLY WATER = 100 PSI MAX
RETURN WATER = 80 PSI MAX
DIFFERENTIAL
=
5 PSI MIN
AIR PRESSURE = 80 PSI MIN
LR63883
7A @ 120VAC / 24VDC
NRTL / C
RLLC
In-Line Style
5.13
(130.3 mm)
4.7
(119.4 mm)
COOLING WATER
Shut Off
Switch Setting
Inadequate Flow
Operational
INDICATION
F L O W
M O N I T O R S
MODEL
NO.
ROCON
NO.
SERIAL
NO.
WARNING: This instrument was made for the specific use stated at
time of order. Any other use may cause injury. Read instructions
before using. U.S. and foreign patents pending.
INDICATOR LIGHT CODE
8.1
(205.7 mm)
WATER FLOW = ON
AIR RESTART = ON
OR LOCKOUT = ON
WATER FLOW = FAULT
WATER / AIR PRESSURE LIMITS
SUPPLY WATER = 100 PSI MAX
RETURN WATER = 80 PSI MAX
DIFFERENTIAL
=
5 PSI MIN
AIR PRESSURE = 80 PSI MIN
LR63883
7A @ 120VAC / 24VDC
NRTL / C
RLLC
Displaced
Tip
HOW TO ORDER
Select appropriate symbols and build a model code number, as in example shown:
Example:
SERIES
Water Control Valve
WCV - S - 4 - H - 7 - A3N5 - A - L -
**** - *****
= WCV
STYLE
Inline
Valve body (w/subplate)
Valve body only
Subplate only
= I
=S
=B
=M
DESIGN NUMBER
Factory to provide at time of quote
(internal reference only)
PORT SIZE
Styles I, S or M (1/2 NPTF)
=4
Styles I, S or M (3/4 NPTF)
=6
Style B (Valve body w/o subplate)= 0
OPTIONS
LOCKOUT, MANUAL
= L **
CARTRIDGE SIZE
INLINE or SUBPLATE
GPM
PSIG-Differential
1/2-3
Low to High
VOLTAGE
=H
120 V
24 V
AC
DC
=A
=D
1- RESTART
3- LIGHTS
Manual
=M
Air
=A
Air with Electrical
Interchange
=E
No lights
=N
ON (Green) / OFF (Red) = A
ON (Green) / OFF (Red)
With Lockout (Yellow)
= C**
**Optional lockout must be selected
2- READOUT SWITCH
3 Wire SPDT
4- ELECTRICAL CONNECTOR
=3
No Receptacle
4 Pin
5 Pin
7 Pin
=N
=4
=5
=7
1755 E. Nine Mile Road P.O. Box 249 Hazel Park, MI 48030
Tel 248-542-9635 Fax 248-398-4274
WWW http://www.flowmeters.com/ E-Mail ufm@flowmeters.com
F L O W
M O N I T O R S
ROCON L.L.C.
Catalog WCV-100.00
Printed in USA
3/98
10M