lotus PRO Technical Bulletin

lotus PRO Stabilization Module Conversion Guide


Stabilization Module
4.25

High Capacity Unit


(HCU)

Filter Cartridge
Chemical-free cleaner, stain-remover, deodorizer
and sanitizer.

Performance Indicators
1.5

Service Light

System Ready
System Charging
Water/Ozone Low
Replace Filter

SERVICE

FLOW
OFF

ON

TO OPERATE:
1. To start Press FLOW to ON.
2. Dispense when SYSTEM READY is GREEN.
3. Press FLOW to OFF when not dispensing.

Ensure that the water


pressure is at minimum
30 PSI (207 kPa) and
maximum 65 PSI (488 kPa)

COLD WATER IN
hose

COLD WATER IN

FLOW
OFF/ON Switch

OZONE SOLUTION OUT

45
30
15

60

psi

75

QUICK DISCONNECTS

WATER IN TO
STABILIZATION MODULE

hose

*Above diagram is a representation only

OZONE SOLUTION OUT


hose

US and International Patents and Patents Pending.

1.

Remove hose with tap fitting from High Capacity Unit WATER IN on HCU (may need to cut hose after removing clamp and discard)

2.

Align Stabilization Module with High Capacity Unit as shown.

3.

Mount Stabilization Module bracket to wall with a minimum spacing of 1.5 from the High Capacity Unit. Mount will be 4.25 from the closest
HCU mount. Use bracket as template mark holes on wall using a 1/4 drill bit. Place a blue plastic insert in each holes (4) using a hammer.
Screw brackets to wall using supplied 8 X 1 1/4 screws.

4.

Once brackets are mounted, hang Stabilization Module.

5.

Attach quick disconnect to COLD WATER IN on Stabilization Module (blue color fittings on left side connection facing unit)

6.

Attach connector hose supplied to right side outlet on Stabilization Module attach opposite end to WATER IN on HCU. (white color fittings
into grey)
Ensure that the water pressure is at minimum 30 PSI (207 kPa) and maximum 65 PSI (488 kPa). This can be checked with a simple water
pressure testing gauge available at most hardware stores.
Attach hose without fittings to OZONE SOLUTION OUT barbed fitting - clamp is not required.
Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
Remove booster hose with colder fitting.
Snap off plug end where this hose was connected.
Fill hole with Super Glue or Epoxy.
Open unit by removing the from cover. (Be sure to not pull on cover)
Disconnect boost solenoid wiring harness from main board.
Remove hose from bottom of venturi and fill hole with glue or epoxy. (At this time solenoid can be removed as well)
Remount front cover watching not to crimp any connections.

7.
8.
9.
10.
11.
12.
13.
14.
15.
16.

For further information please call Tersano at 1-800-808-1723.

Approved. Proven. Powerful.


Chemical-Free Cleaning, Sanitizing & Stain Removal.

1-800-808-1723
www.tersanoprofessional.com