Lighting controls
Replace T-12 tubes by T-8 tubes
Replace mercury lights with metal halide or high pressure sodium lights
Replace metal halide (HID) with high-intensity fluorescent lights
Replace magnetic ballasts with electronic ballasts
Optimization of plant lighting (Lux optimization) in production and
non-production departments
7. Optimum use of natural sunlight
8/4/2015 1:26 PM
2 of 7
http://electrical-engineering-portal.com/7-energy-efficiency-improvement...
1. Lighting controls
Lights can be shut off during non-working hours by automatic controls, such as
occupancy sensors which turn off lights when a space becomes unoccupied. Manual
controls can also be used in addition to automatic controls to save additional energy in
smaller areas.
The payback period for lighting control systems is generally less than 2 years.
8/4/2015 1:26 PM
3 of 7
http://electrical-engineering-portal.com/7-energy-efficiency-improvement...
In industry, typically T-12 tubes have been used. T-12 refers to the diameter in 1/8 inch
increments (T-12 means 12/8 inch or 3.8 cm diameter tubes). The initial output for these
lights is high, but energy consumption is also high.
They (T-12) also have extremely poor efficiency, lamp life, lumen
depreciation, and color rendering index. Because of this, maintenance and
energy costs are high.
Replacing T-12 lamps with T-8 lamps approximately doubles the efficacy of the
former, thereby saves electricity.
3. Replace mercury lights with Metal halide or High pressure sodium lights
Where color rendition is critical, metal halide lamps can replace mercury or fluorescent
lamps with an energy savings of 50%. Where color rendition is not critical, high
pressure sodium lamps offer energy savings of 50 to 60% compared to mercury lamps.
8/4/2015 1:26 PM
4 of 7
http://electrical-engineering-portal.com/7-energy-efficiency-improvement...
In addition to energy savings and better lighting qualities, high-intensity fluorescents can
help to reduce maintenance costs.
8/4/2015 1:26 PM
5 of 7
http://electrical-engineering-portal.com/7-energy-efficiency-improvement...
Go back to
Optimisation List
6. Optimization of plant
lighting (Lux
optimization)
In production and
non-production departments
In many
plants the
lighting
system is
not
specifically
designed
for the
process.
There are
lux
standards
for each
type of
textile
process.
For instance, the required lux for weaving is usually higher than that of
wet-processing. Even within just one production process, the required lux
varies by the process step.
For example, in a cotton spinning process, the required lux in the blow room should be
much lower than that of ring frame section. If the lighting provided is higher than the
standard (required lux) for any part of the production, this results in a waste of electricity.
8/4/2015 1:26 PM
6 of 7
http://electrical-engineering-portal.com/7-energy-efficiency-improvement...
Therefore, the plant engineers should optimize the lighting system based on the
standard lux specific for each process step.
Recommended EE articles //
8/4/2015 1:26 PM
7 of 7
http://electrical-engineering-portal.com/7-energy-efficiency-improvement...
About Author //
Edvard Csanyi
Edvard - Electrical engineer, programmer and founder of EEP.
Highly specialized for design of LV high power busbar trunking
(<6300A) in power substations, buildings and industry fascilities.
Designing of LV/MV switchgears.Professional in AutoCAD
programming and web-design.Present on Google+