GENERAL
1. Unless otherwise noted on this drawing, all materials and workmanship
shall be of quality compatible with the requirements of the specification.
2. General notes and tpcal detail shall apply to all drawing unless otherwise
shown or noted.
3. All dimension are in metric system, the basic unti of length is the
milimeter.
4. Unless otherwise noted, details shown on any drawings are to be
considered typical for all similiar condition. Details not shown on the
drawings shall be clarified to meet the specific condition by the shop
drawings and shall be reviewed by the engineer.
5. All dimension and condition shall be verified by the contractor and any
discrepancies shall be brought to the attention of the arcitect or the
engineer before proceeding with the portions of work involved.
6. The contractor shall verified and coordinate all opening in floord, beams,
wall and roof, and shall check any concrete embeddings, such as conduit
pipe, sleeve pipe and outlet, etc., with arcitectural, mecehanical, and
electrical drawings.
7. The condition shall provide all measures and precautions necessary to
prevent settlement or any damage of adjacent existing or new
construction.
8. The constraction load on the floor should not exceed the specific design
live load during any stage of construction.
9. The contractor shall provide periodic elevation readings at specified
locations. Readings shall be taken and recorded at the completion of each
floor level by licensed surveyor wich approved by engineer. Recording
shall be submitted to the engineer of the completion of each floor level
FOUNDATION
1. Foundation is design based on soil test report prepared by PT. SOLEFOUND
SAKTI
2. The following fondation shall be used :
- Type of foundation
: bored pile
- Pile size
: 800
- Effective length
: 28 M
3. Excavation system
: Open cut and braced cut ( soldier pile )
4. Allowable capacity of pile :
- Compression
: 800mm : 350 ton
- Tension
: 800mm : 150 ton
5. Loading test for pile :
- Compression Test
: 800mm : 2 NOS 2.5 x 350
= 875 ton
2 NOS 2 x 350
-
Lateral Test
= 700 ton
6. Actual pile legnth could vary from the design length based on the actual
soil condition at the site subject to the engineer approval.
MIN. FY
BJTD U-40
400 Mpa
BAR
ROATATION
D10 THRU D32
BJTP U-24
240 MPa
6 THRU 16
POROTION
REMARKS
MAIN BARS,
HOOPS,
STIRRUPS,
SLAB BARS
SPIRAL OF
BORED PILE,
HOOK & JOINT
OF PC PANEL
DEFORMED
BARS
PLAIN BARS
5.
6.
7.
8.