ANALYSIS OF MOMENT RESISTING FRAME & LATERAL LOAD DISTRIBUTION

LATERAL LOAD DISTRIBUTION OF FRAME BUILDING:

In a two dimensional moment resisting frame each joint can have at the most three degrees of
freedom (displacement in horizontal and vertical directions and rotation).

Total number of degree of freedom is 3Nj where Nj is the number of joints in the frame.

In practice, beams carry very small axial force and undergo negligible axial deformation. This
means horizontal displacement at all joints located at the beam level s same.

In most buildings uptown moderate height, the axial deformation of columns is negligible.

Numbers of degrees of freedom are reduced to one rotation and one horizontal displacement.

As the rotational inertia associated with the rotational degree of freedom is insignificant, it is
further possible to reduce, through static condensation, the number of degrees to one per storey for
carrying out dynamic analysis.

In similar way, each joint of three dimensional frames can have at most six degrees of freedom.

Finally, there are three degrees of freedom per floor.

Free vibration analysis of the building can thus be carried out by solving (3N*3N) Eigen value
problem, where N is the number of storeys in the building.

Once natural frequency and more shape is known it is possible to obtain the maximum seismic
force to be applied at each storey level due to given earthquake ground motion.

LATERAL LOAD ANALYSIS OF MOMENT RESISTING FRAME:

Once the design lateral loads are known on the two-dimensional frames, one could analyze the
frame for the member forces.

One could carry out an accurate computer analysis or an approximate analysis as per
requirement.

Approximate analysis is usually performed at preliminary design stage and to assess the
computer analysis.

Two commonly used methods:A. Portal frame method:


Frames: Portal frames are frequently used over the entrance of a bridge and as a main stiffness
element in building design in order to transfer horizontal forces applied at the top of the frame to the

foundation. On bridges, these frames resist the forces caused by wind, earthquake, and
unbalanced traffic loading on the bridge deck. Portals can be pin supported, fixed supported, or
supported by partial fixity. The approximate analysis of each case will now be discussed for a
simple three-member portal.

Pin-Supported Portals: A typical pin-supported portal frame is shown in Fig. 1 (a). Since four
unknowns exist at the supports but only three equilibrium equations are available for solution, this
structure is statically indeterminate to the first degree. Consequently, only one assumption must be
made to reduce the frame to one that is statically determinate.
The elastic deflection of the portal is shown in Fig. 1(b). This diagram indicates that a point of
inflection, that is, where the moment changes from positive bending to negative bending, is located
approximately at the girders midpoint. Since the moment in the girder is zero at this point, we can
assume a hinge exists there and then proceed to determine the reactions at the supports using
statics. If this is done, it is found that the horizontal reactions (shear) at the base of each column
are equal and the other reactions are those indicated in Fig. 1(c). Furthermore the moment
diagrams, for this frame, are indicted in Fig. 1(d).

Fig. 1 Portal frame pin-supported at base


Fixed-Supported Portals: Portal with two fixed supports, Fig. 2(a) are statically indeterminate to
the third degree since there is a total of six unknowns at the supports. If the vertical members have
equal lengths and cross-sectional areas the frame will deflect as shown in Fig. 2(b). For this case,

we will assume points of inflection occur at the midpoints of all three members, and therefore
hinges are placed at these points. The reactions and moment diagrams for each member can
therefore be determined by dismembering the frame at the hinges and applying the equations of
equilibrium to each of the four parts. The results are shown in Fig. 2(c). Note that, as in the case of
the pin-connected portal, the horizontal reactions (shear) at the base of each column are equal. The
moment diagram for this frame is indicted in Fig. 2(d).

Fig. 2 Analysis of portal frames Fixed at base


Partially Fixed (at the Bottom) Portal: Since it is both difficult and costly to construct a perfectly
fixed support or foundation for a portal frame, it is a conservative and somewhat realistic estimate
to assume a slight rotation to occur at the supports, as shown in Fig. 3(a). As a result, the points of
inflection on the columns lie somewhere between the case of having a pin-supported portal (as
shown in Fig. 1(a)), where the inflection points are at the supports (base of columns), and that of a
fixed-supported portal (as shown in Fig. 2(a)), where the inflection points lie at the center of the

columns. Many engineers arbitrarily define the location at h/3 (Fig. 3(b)), and therefore place hinges
at these points, and also at the center of the girder.

Fig. 3 Portal frame partially fixed at base


Trussed Frames: When a portal is used to span large distances, a truss may be used in place of
the horizontal girder. Such a structure is used on large bridges and as transverse bents for large
auditoriums and mill buildings. A typical example is shown in Fig. 4(a). In all cases, the suspended
truss is assumed to be pin connected at its points of attachment to the columns. Furthermore, the
truss keeps the columns straight within the region of attachment when the portals are subjected to
the sidesway D, Fig. 4(b). Consequently, we can analyze trussed portals using the same
assumptions as those used for simple portal frames. For pin-supported columns, assume the
horizontal reactions (shear) are equal, as in Fig. 1(c). For fixed-supported columns, assume the
horizontal reactions are equal and an inflection point (or hinge) occurs on each column, measured
midway between the base of the column and the lowest point of truss member connection to the
column. See Fig. 2(c) and Fig. 4(b).

Fig. 4 Trussed frame fixed at base


Lateral loads on Building Frames: Portal Frame Method
The action of lateral loads on portal frames and found that for a frame fixed supported at its base,
points of inflection occur at approximately the center of each girder and column and the columns
carry equal shear loads, Fig. 2. A building bent deflects in the same way as a portal frame, Fig.5 (a),
and therefore it would be appropriate to assume inflection points occur at the center of the columns
and girders. If we consider each bent of the frame to be composed of a series of portals, Fig. 5 (b),
then as a further assumption, the interior columns would represent the effect of two portal columns
and would therefore carry twice the shear V as the two exterior columns.
Consider the 2-D frame with m-base and n-storeys. The degree of indeterminacy of the frame is
3mn. To analyze the frame, 3mn assumptions are made;

The point of contra-flexure in the column is at mid-height of the columns: (m+1)n assumptions.

The point of contra-flexure in the beams is at the mid span of the beams: mn assumptions.

Axial force in the internal columns is zero (m+1)n assumptions.

With the above assumptions, the frame becomes statically determinate and member forces are
obtained simply by considering equilibrium.

B. Cantilever method: In this method also, 3mn assumptions are to be made to make the frame
statically determinate; the point of contra-flexure in the column is at mid-height of the columns:
(m+1)n assumptions.

The point of contra-flexure in the beams is at mod span of the beams: mn assumptions.

Axial force in the columns is approximated by assuming that the frame behaves as a cantilever
beam. Neutral axis of the frame is obtained using the column area of cross section and the column
location, axial stress in the column is assumed to vary linearly from this neutral axis: (m-1)n
assumptions.
The cantilever method is based on the same action as a long cantilevered beam subjected to a
transverse load. It may be recalled from mechanics of materials that such a loading causes a
bending stress in the beam that varies linearly from the beams neutral axis, Fig. 6 (a). In a similar
manner, the lateral loads on a frame tend to tip the frame over, or cause a rotation of the frame

about a neutral axis lying in a horizontal plane that passes through the columns at each floor level.
To counteract this tipping, the axial forces (or stress) in the columns will be tensile on one side of
the neutral axis and compressive on the other side as in Fig below. Like the cantilevered beam, it
therefore seems reasonable to assume this axial stress has a linear variation from the centroid of
the column areas or neutral axis. The cantilever method is therefore appropriate it the frame is tall
and slender, or has columns with different cross-section areas.