Sei sulla pagina 1di 28

Carisma

TheUltraQuiet FanCoil

Range Basics
RangeBasics
AcompleterangeoffancoilsforusewithHotwaterfor
heatingandchilledwaterforcooling
EuroventCertified

TypicalApplications
yp
pp

Schools
Hotels
CommercialPremises
PublicBuildings

MV

CRC

9Sizes

3+1Rows
3 Rows
3Rows
3+2Rows

MOMVB
IVIO

4Rows

4+1Rows

AirFlowRangem3/h

CRC

100 150050Pa

CRC 13

MODEL
Speed
Air Flow
Cooling total emission
Cooling sensible emission
Heating
P Cooling
P Heating
Power consumption
Sound Power level
Sound Pressure level

mc/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)

1
low
105
0,59
0,47
0,76
0,9
08
0,8
16
32
23

125
0,68
0,54
0,90
1,1
09
0,9
19
34
25

150
0,77
0,62
1,02
1,4
12
1,2
21
36
27

Speed

1
mc/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)

185
1,27
0,93
1,50
6,5
5,5
14
27
18

2
low
265
1,73
1,28
2,09
11,2
9,5
21
33
24

195
0,94
0,78
1,26
2,0
17
1,7
29
42
33

6
max
220
1,03
0,86
1,39
2,3
20
2,0
33
45
36

1
low
145
0,91
0,69
1,12
2,5
21
2,1
14
30
21

2
170
1,01
0,77
1,27
3,0
26
2,6
16
33
24

3
med
335
2,14
1,60
2,61
16,2
13,8
28
39
30

4
400
2,46
1,86
3,02
20,8
17,7
34
43
34

Speed

1
mc/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)

445
2,87
2,13
3,41
,
12,3
10,5
44
38
29

2
low
535
3,34
2,50
4,01
,
16,2
13,8
54
42
33

3
630
3,80
2,87
4,60
,
20,3
17,3
66
47
38

4
med
735
4,29
3,27
5,19
,
25,1
21,3
79
51
42

3
med
220
1,25
0,97
1,59
4,4
37
3,7
22
40
31

4
250
1,38
1,08
1,77
5,3
45
4,5
26
43
34

CRC 33
5
max
295
1,56
1,24
2,02
6,5
55
5,5
32
47
38

340
1,74
1,40
2,28
7,9
67
6,7
40
51
42

185
1,28
0,94
1,52
6,6
56
5,6
15
31
22

2
low
235
1,57
1,15
1,87
9,4
80
8,0
20
36
27

CRC 53
5
max
485
2,87
2,19
3,56
27,2
23,1
44
47
38

570
3,24
2,51
4,06
33,8
28,7
57
52
43

250
1,68
1,24
1,98
4,1
3,5
18
26
17

2
low
315
2,03
1,51
2,42
5,8
4,9
22
31
22

CRC 73

MODEL

Air Flow
Cooling total emission
Cooling sensible emission
Heating
g
P Cooling
P Heating
Power consumption
Sound Power level
Sound Pressure level

CRC 43

MODEL

Air Flow
Cooling total emission
Cooling sensible emission
Heating
P Cooling
P Heating
Power consumption
S
Sound
d Power
P
level
l
l
Sound Pressure level

4
med
175
0,86
0,71
1,15
1,7
14
1,4
25
39
30

CRC 23

3
420
2,58
1,94
3,13
8,8
7,5
32
37
28

4
med
495
2,94
2,23
3,59
11,1
9,4
39
41
32

840
4,76
3,66
5,80
,
30,1
25,6
92
54
45

6
max
925
5,11
3,95
6,27
,
34,2
29,1
103
56
47

1
510
3,06
2,32
3,84
,
6,1
5,2
47
39
30

2
low
655
3,74
2,88
4,80
,
8,7
7,4
62
45
36

3
815
4,41
3,44
5,61
,
11,6
9,9
81
50
41

4
med
1020
5,19
4,12
6,74
,
15,5
13,2
105
56
47

4
325
2,07
1,55
2,52
15,4
13 1
13,1
32
45
36

5
max
385
2,39
1,80
2,92
19,7
16 7
16,7
41
49
40

6
440
2,66
2,02
3,27
23,8
20 2
20,2
49
52
43

CRC 63
5
545
3,18
2,43
3,89
12,7
10,8
46
43
34

6
max
650
3,64
2,82
4,50
16,2
13,8
61
48
39

1
low
415
2,54
1,91
3,07
8,6
7,3
37
37
28

2
505
2,99
2,27
3,66
11,4
9,7
46
42
33

CRC 83
5

3
med
270
1,78
1,32
2,15
11,8
10 0
10,0
25
40
31

3
med
590
3,37
2,59
4,13
14,1
12,0
55
46
37

4
680
3,77
2,93
4,68
17,2
14,6
67
49
40

5
max
760
4,09
3,20
5,09
19,8
16,8
78
52
43

6
830
4,35
3,44
5,45
22,1
18,8
88
54
45

CRC 93
5
1100
5,47
4,37
7,15
,
17,1
14,5
116
58
49

6
max
1200
5,82
4,68
7,66
,
19,0
16,2
130
60
51

1
735
4,08
3,16
5,21
,
10,2
8,7
78
47
38

2
low
830
4,47
3,49
5,71
,
11,9
10,1
92
50
41

3
980
5,06
4,00
6,54
,
14,8
12,6
108
54
45

4
med
1210
5,87
4,73
7,72
,
19,3
16,4
134
58
49

5
1365
6,36
5,19
8,47
,
22,2
18,9
152
62
53

6
max
1500
6,74
5,55
9,06
,
24,6
20,9
176
64
55

AirInlet/OutletOptions
p
=MV
Verticalcasing

=MOMVB
Horizontalcasing
Ceilinginstallation

=MOMVB
Horizontalcasing
Floorinstallation

AirInlet/OutletOptions
=IVIO
Concealed

=IVIO

Key Construction Features


KeyConstructionFeatures
OuterCasing
MVandMOMVBmodels
Casingmadefromgalvanisedprepaintedsteel
Topgrillinonesinglepieceforallsizesforthebest
designandstrength.Constructedwithfixedreversible
louvrestoallowdualairdistribution

InnerCasing
IV IO models
IVIO
Manufacturedfromgalvanisedsteelwithclosed
cellinsulation

Key Construction Features


KeyConstructionFeatures

F
FanandMotorAssemblies
dM t A
bli
CRCVersions
Fanassembly Directdrivecentrifugalblowers,tested
and balanced to ensure silent operation
andbalancedtoensuresilentoperation
Motor Singlephasewith6speeds
(3ofwhichconnected),fittedwithsealed
forlifebearingsandmountedonantivibration
andselflubricatingmounts

Key Construction Features


KeyConstructionFeatures
Heatexchanger
H
h
Constructedusingdrawncoppertubewithmechanicallybonded
aluminiumfins
inchBSPconnectionsoncoilwith1/8inchBSPairventanddrain
Flowandreturnpipeconnectionsaresituatedonlefthandsideas
standard (looking at unit) but right hand side connections can be
standard(lookingatunit),butrighthandsideconnectionscanbe
factoryorsitefitted

Condensatecollectiontray
Manufacturedfromplastic,Lshapedfittedtoinnercasing

Filter
Washable
Washablesyntheticfilterencasedinametalframewhichfitsinto
synthetic filter encased in a metal frame which fits into
specialslidingguidestoallowforeasyinsertionandremoval.

Guide to Model Nomenclature


GuidetoModelNomenclature

CRC 43 MV
MV=Verticalcasing
MOMVB=Horizontal/Lowvertical
casing

C =CentrifugalFanOption
C
= Centrifugal Fan Option

IVIO=Concealed

Size

4 3

Rows

10room
10
room
module

13onboard

29
29
Controls

3IRversion

Free
Free
Sabiana

2wall 503
version

Electroniccontrolstobefittedon
theunit
Model:CB
ONOFFswitchand3speedswitch.

Model:CBT
Electronicroomthermostatforfanorvalvescontrol(ON
OFF).

Electroniccontrolstobefittedon
theunit
Model:CBC
SamecontrolastheCBT,buttheSummer/Winterswitchis
l
h
b h
/ i
i hi
centralizedandremote,oranautomaticchangeoverisfittedonthe
waterpipe(for2tubeinstallationsonly).

Model:CBAU
Automaticspeedselection
Itallowstocontrolthesummer/wintercyclewithacentralizedandremoteswitch
orwithanautomaticchangeoverisfittedonthewaterpipe(for2tube
installationsonly).
With4pipeinstallationsandcontinuouschilledandhotwatersupply,itallows
theautomaticsummer/winterchangeoverinaccordancetotheroom
temperature(1C=Winter,+1C=Summer,NeutralZone2C).
( 1C Wi
1C S
N
lZ
2C)

Electroniccontrols to be fitted ontheunit

Model:SELCB
Speed switch (Slave):it allows to control up to 8 units
Speedswitch(Slave):itallowstocontrolupto8units

Remoteelectroniccontrols

Model:MO3V
ON OFF i h d 3
ONOFFswitchand3speedswitch.
d i h

Model:TMOT
Electronic room thermostat for fan or valves control (ON OFF)
Electronicroomthermostatforfanorvalvescontrol(ONOFF).

Remoteelectroniccontrols
Model:TMOTAU
Automaticspeedswitch.
p
With4pipeinstallationsandcontinuouschilledandhotwater
supply,itallowstheautomaticsummer/winterchangeoverin
accordancetotheroomtemperature(1C=Winter,+1C=Summer,
NeutralZone2C).

Model:TMO503andTMO503SV2
TheTMO503control,withabigandcleardisplay,isdesignedtobe
installedinaseries503wallbox.

Model:SELCR
S
Speedswitch(Slave):itallowstocontrolupto8units
d i h (Sl ) i ll
l
8 i

Remote electronic controls


Remoteelectroniccontrols
Model:TMODI
Multifunctioncontrolwithliquidcrystalldisplay.

Model:SELDI
Speedswitch(Slave):itallowstocontrolupto10unitswithonly
one TMODI
oneTMO
DIcontrol
control

Unit with infrared


Unitwithinfra
redremotecontrol
remote control
TheCRCunitscanbesuppliedwithamicroprocessor
managingsystemoperatedbyaninfraredremotecontrol
withliquidcrystalldisplay.
AgroupofCRCunitswithinfrared
remotecontrolmicroprocessor
can be connected via a serial link
canbeconnectedviaaseriallink
andcanconsequentlybemanaged
atthesametimebyjustoneinfra
redremotecontrol.

Maxinetprogramformanaginga
networkofSabianaIRhydronicterminals
Type:Maxinet
i
MaxinetisacentralisedcontrolsystemfornetworksofSabianaIR
hydronic terminals, based on software that runs on Windows. The
hydronicterminals,basedonsoftwarethatrunsonWindows.The
Maxinetsoftwareoffersapracticalandeconomicalsolutionfor
managingtheterminals,withthesimpleclickofthemouse.

Thewirelss control system

Valve Accessories
ValveAccessories

VBP Maincoil3wayvalve
3wayvalve,ONOFF,
withelectricmotorandmountingkit
withmicrometriclockshieldvalve.

VBA Additionalcoil3wayvalve
3
3wayvalve,ON
way valve, ONOFF,
OFF,
withelectricmotorandmountingkit
withmicrometriclockshieldvalve.

Valve Accessories
ValveAccessories
VS Simplifiedkitfor3way
valve(concealedmodelonly)
3wayvalve,(ONOFF)withelectricmotorand
mountingkit.
Valvewithflatconnectionwithoutmicrometric
lockshieldvalve.

V2
V2 2wayvalveformainand
2
l f
i
d
additionalcoil
Controlvalvekit:2wayvalve,ON
Control
valve kit: 2 way valve ONOFF
OFF,
withelectricmotorandmountingkit.

Valves and kit


Valvesandkit
2wayvalveswith
2
way valves with
connectionskit
3wayvalveswith
3
l
ith
connectionskit

3wayvalveswith
micrometric
lockshield valve
lockshieldvalve

Accessories

BELElectricheatingelement

Designedforuseascomplimentaryheating

Sizes from 1kW upto 2 5kW


Sizesfrom1kWupto2,5kW

Condensatecollectiontraytoencompassvalveassembly
BSVforMV,IVandMVBmodels
BSOforMOandIOmodels

SCRCondensatedrainpipe
pp

PAPExtensionfeet

100mm

Accessories
Accessories

SAEFreshAirMixingdamper
StaticorMotorizedonrequested
Static or Motorized on requested

PCVRearclosurepanel

PCOBottomclosurepanel

KAFFrontalintakekit
ForusewithIVIOmodels,complete
withbottomclosingpanelandfilterslideguides
ith b tt
l i
l d filt lid
id

Potrebbero piacerti anche