Range Basics
RangeBasics
AcompleterangeoffancoilsforusewithHotwaterfor
heatingandchilledwaterforcooling
EuroventCertified
TypicalApplications
yp
pp
Schools
Hotels
CommercialPremises
PublicBuildings
MV
CRC
9Sizes
3+1Rows
3 Rows
3Rows
3+2Rows
MOMVB
IVIO
4Rows
4+1Rows
AirFlowRangem3/h
CRC
100 150050Pa
CRC 13
MODEL
Speed
Air Flow
Cooling total emission
Cooling sensible emission
Heating
P Cooling
P Heating
Power consumption
Sound Power level
Sound Pressure level
mc/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
1
low
105
0,59
0,47
0,76
0,9
08
0,8
16
32
23
125
0,68
0,54
0,90
1,1
09
0,9
19
34
25
150
0,77
0,62
1,02
1,4
12
1,2
21
36
27
Speed
1
mc/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
185
1,27
0,93
1,50
6,5
5,5
14
27
18
2
low
265
1,73
1,28
2,09
11,2
9,5
21
33
24
195
0,94
0,78
1,26
2,0
17
1,7
29
42
33
6
max
220
1,03
0,86
1,39
2,3
20
2,0
33
45
36
1
low
145
0,91
0,69
1,12
2,5
21
2,1
14
30
21
2
170
1,01
0,77
1,27
3,0
26
2,6
16
33
24
3
med
335
2,14
1,60
2,61
16,2
13,8
28
39
30
4
400
2,46
1,86
3,02
20,8
17,7
34
43
34
Speed
1
mc/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
445
2,87
2,13
3,41
,
12,3
10,5
44
38
29
2
low
535
3,34
2,50
4,01
,
16,2
13,8
54
42
33
3
630
3,80
2,87
4,60
,
20,3
17,3
66
47
38
4
med
735
4,29
3,27
5,19
,
25,1
21,3
79
51
42
3
med
220
1,25
0,97
1,59
4,4
37
3,7
22
40
31
4
250
1,38
1,08
1,77
5,3
45
4,5
26
43
34
CRC 33
5
max
295
1,56
1,24
2,02
6,5
55
5,5
32
47
38
340
1,74
1,40
2,28
7,9
67
6,7
40
51
42
185
1,28
0,94
1,52
6,6
56
5,6
15
31
22
2
low
235
1,57
1,15
1,87
9,4
80
8,0
20
36
27
CRC 53
5
max
485
2,87
2,19
3,56
27,2
23,1
44
47
38
570
3,24
2,51
4,06
33,8
28,7
57
52
43
250
1,68
1,24
1,98
4,1
3,5
18
26
17
2
low
315
2,03
1,51
2,42
5,8
4,9
22
31
22
CRC 73
MODEL
Air Flow
Cooling total emission
Cooling sensible emission
Heating
g
P Cooling
P Heating
Power consumption
Sound Power level
Sound Pressure level
CRC 43
MODEL
Air Flow
Cooling total emission
Cooling sensible emission
Heating
P Cooling
P Heating
Power consumption
S
Sound
d Power
P
level
l
l
Sound Pressure level
4
med
175
0,86
0,71
1,15
1,7
14
1,4
25
39
30
CRC 23
3
420
2,58
1,94
3,13
8,8
7,5
32
37
28
4
med
495
2,94
2,23
3,59
11,1
9,4
39
41
32
840
4,76
3,66
5,80
,
30,1
25,6
92
54
45
6
max
925
5,11
3,95
6,27
,
34,2
29,1
103
56
47
1
510
3,06
2,32
3,84
,
6,1
5,2
47
39
30
2
low
655
3,74
2,88
4,80
,
8,7
7,4
62
45
36
3
815
4,41
3,44
5,61
,
11,6
9,9
81
50
41
4
med
1020
5,19
4,12
6,74
,
15,5
13,2
105
56
47
4
325
2,07
1,55
2,52
15,4
13 1
13,1
32
45
36
5
max
385
2,39
1,80
2,92
19,7
16 7
16,7
41
49
40
6
440
2,66
2,02
3,27
23,8
20 2
20,2
49
52
43
CRC 63
5
545
3,18
2,43
3,89
12,7
10,8
46
43
34
6
max
650
3,64
2,82
4,50
16,2
13,8
61
48
39
1
low
415
2,54
1,91
3,07
8,6
7,3
37
37
28
2
505
2,99
2,27
3,66
11,4
9,7
46
42
33
CRC 83
5
3
med
270
1,78
1,32
2,15
11,8
10 0
10,0
25
40
31
3
med
590
3,37
2,59
4,13
14,1
12,0
55
46
37
4
680
3,77
2,93
4,68
17,2
14,6
67
49
40
5
max
760
4,09
3,20
5,09
19,8
16,8
78
52
43
6
830
4,35
3,44
5,45
22,1
18,8
88
54
45
CRC 93
5
1100
5,47
4,37
7,15
,
17,1
14,5
116
58
49
6
max
1200
5,82
4,68
7,66
,
19,0
16,2
130
60
51
1
735
4,08
3,16
5,21
,
10,2
8,7
78
47
38
2
low
830
4,47
3,49
5,71
,
11,9
10,1
92
50
41
3
980
5,06
4,00
6,54
,
14,8
12,6
108
54
45
4
med
1210
5,87
4,73
7,72
,
19,3
16,4
134
58
49
5
1365
6,36
5,19
8,47
,
22,2
18,9
152
62
53
6
max
1500
6,74
5,55
9,06
,
24,6
20,9
176
64
55
AirInlet/OutletOptions
p
=MV
Verticalcasing
=MOMVB
Horizontalcasing
Ceilinginstallation
=MOMVB
Horizontalcasing
Floorinstallation
AirInlet/OutletOptions
=IVIO
Concealed
=IVIO
InnerCasing
IV IO models
IVIO
Manufacturedfromgalvanisedsteelwithclosed
cellinsulation
F
FanandMotorAssemblies
dM t A
bli
CRCVersions
Fanassembly Directdrivecentrifugalblowers,tested
and balanced to ensure silent operation
andbalancedtoensuresilentoperation
Motor Singlephasewith6speeds
(3ofwhichconnected),fittedwithsealed
forlifebearingsandmountedonantivibration
andselflubricatingmounts
Condensatecollectiontray
Manufacturedfromplastic,Lshapedfittedtoinnercasing
Filter
Washable
Washablesyntheticfilterencasedinametalframewhichfitsinto
synthetic filter encased in a metal frame which fits into
specialslidingguidestoallowforeasyinsertionandremoval.
CRC 43 MV
MV=Verticalcasing
MOMVB=Horizontal/Lowvertical
casing
C =CentrifugalFanOption
C
= Centrifugal Fan Option
IVIO=Concealed
Size
4 3
Rows
10room
10
room
module
13onboard
29
29
Controls
3IRversion
Free
Free
Sabiana
2wall 503
version
Electroniccontrolstobefittedon
theunit
Model:CB
ONOFFswitchand3speedswitch.
Model:CBT
Electronicroomthermostatforfanorvalvescontrol(ON
OFF).
Electroniccontrolstobefittedon
theunit
Model:CBC
SamecontrolastheCBT,buttheSummer/Winterswitchis
l
h
b h
/ i
i hi
centralizedandremote,oranautomaticchangeoverisfittedonthe
waterpipe(for2tubeinstallationsonly).
Model:CBAU
Automaticspeedselection
Itallowstocontrolthesummer/wintercyclewithacentralizedandremoteswitch
orwithanautomaticchangeoverisfittedonthewaterpipe(for2tube
installationsonly).
With4pipeinstallationsandcontinuouschilledandhotwatersupply,itallows
theautomaticsummer/winterchangeoverinaccordancetotheroom
temperature(1C=Winter,+1C=Summer,NeutralZone2C).
( 1C Wi
1C S
N
lZ
2C)
Model:SELCB
Speed switch (Slave):it allows to control up to 8 units
Speedswitch(Slave):itallowstocontrolupto8units
Remoteelectroniccontrols
Model:MO3V
ON OFF i h d 3
ONOFFswitchand3speedswitch.
d i h
Model:TMOT
Electronic room thermostat for fan or valves control (ON OFF)
Electronicroomthermostatforfanorvalvescontrol(ONOFF).
Remoteelectroniccontrols
Model:TMOTAU
Automaticspeedswitch.
p
With4pipeinstallationsandcontinuouschilledandhotwater
supply,itallowstheautomaticsummer/winterchangeoverin
accordancetotheroomtemperature(1C=Winter,+1C=Summer,
NeutralZone2C).
Model:TMO503andTMO503SV2
TheTMO503control,withabigandcleardisplay,isdesignedtobe
installedinaseries503wallbox.
Model:SELCR
S
Speedswitch(Slave):itallowstocontrolupto8units
d i h (Sl ) i ll
l
8 i
Model:SELDI
Speedswitch(Slave):itallowstocontrolupto10unitswithonly
one TMODI
oneTMO
DIcontrol
control
Maxinetprogramformanaginga
networkofSabianaIRhydronicterminals
Type:Maxinet
i
MaxinetisacentralisedcontrolsystemfornetworksofSabianaIR
hydronic terminals, based on software that runs on Windows. The
hydronicterminals,basedonsoftwarethatrunsonWindows.The
Maxinetsoftwareoffersapracticalandeconomicalsolutionfor
managingtheterminals,withthesimpleclickofthemouse.
Valve Accessories
ValveAccessories
VBP Maincoil3wayvalve
3wayvalve,ONOFF,
withelectricmotorandmountingkit
withmicrometriclockshieldvalve.
VBA Additionalcoil3wayvalve
3
3wayvalve,ON
way valve, ONOFF,
OFF,
withelectricmotorandmountingkit
withmicrometriclockshieldvalve.
Valve Accessories
ValveAccessories
VS Simplifiedkitfor3way
valve(concealedmodelonly)
3wayvalve,(ONOFF)withelectricmotorand
mountingkit.
Valvewithflatconnectionwithoutmicrometric
lockshieldvalve.
V2
V2 2wayvalveformainand
2
l f
i
d
additionalcoil
Controlvalvekit:2wayvalve,ON
Control
valve kit: 2 way valve ONOFF
OFF,
withelectricmotorandmountingkit.
3wayvalveswith
micrometric
lockshield valve
lockshieldvalve
Accessories
BELElectricheatingelement
Designedforuseascomplimentaryheating
Condensatecollectiontraytoencompassvalveassembly
BSVforMV,IVandMVBmodels
BSOforMOandIOmodels
SCRCondensatedrainpipe
pp
PAPExtensionfeet
100mm
Accessories
Accessories
SAEFreshAirMixingdamper
StaticorMotorizedonrequested
Static or Motorized on requested
PCVRearclosurepanel
PCOBottomclosurepanel
KAFFrontalintakekit
ForusewithIVIOmodels,complete
withbottomclosingpanelandfilterslideguides
ith b tt
l i
l d filt lid
id