Recuperatore di calore a flusso incrociato
Cross flow heat recovery unit
APPLICAZIONI e PECULIARIT
GAMMA
RANGE
CONSTRUCTION
COSTRUZIONE
High efficiency static heat recovery unit with aluminum plate, air
flows are separated by a suitable sealing.
Thermo-acoustical insulation of the panels in polyethylene/polyester
with average thickness of 20 mm.
Centrifugal intake and exhaust fan, double inlet type (model ECOM
33 is simple inlet).
Directly coupled electric motor.
Condensing tub in ABS, with condensing plug in the bottom.
Fan unit fixed on antivibration mounts to prevent eventual vibrations.
Panels manufactured in Aluzink sheet.
Air filters efficiency G4, easy to extract to the maintenance purpose.
Removable side panels in Aluzink sheet.
For the models ECOM 110 to ECOM 530 the panels is punched
to allow the by-pass or free-cooling arrangement.
Heat exchanger removal from below.
TECHNICAL SPECIFICATIONS
Conveyed air: clean
Voltage:
Mono-phase version (M) 230V-50Hz.
Three phase version (T) 400V-50Hz. (ECOM 410-530)
SPECIFICHE TECNICHE
Aria convogliata: pulita.
Tensione dalimentazione:
Versione monofase (M) 230V-50Hz.
Versione trifase (T) 400V-50Hz. (ECOM 410/530)
ACCESSORIES
Internal post heating electric resistor ECOM-BE
Internal battery of water post heating ECOM-BW
(except mod. 33-55)
External section with water battery ECOM-SEW
Circular spigots (set of 4 pieces) ECOM-AC
Electronic speed regulator SRE-M (mod. 33-55)
3 speed C3V with controls: on-off/cooling/heating switch
(except mod. 33-55, for mod. 410 - 530 available only 2 speed)
PCM panel with speed control, temperature and on/off switching
water and electric battery (mod. 33-55: 1 speed, mod. 410 - 530:
available only 2 speed)
ACCESSORI
Resistenza elettrica interna di post-riscaldamento ECOM-BE
Batteria interna di post-riscaldamento ad acqua ECOM-BW
(escluso mod. 33-55)
Sezione esterna con batteria ad acqua ECOM-SEW
Kit no 4 attacchi circolari ECOM-AC
Regolatore elettronico di velocit SRE-M (mod.3355)
Selettore 3 velocit C3V con interruttore on-off/estate/inverno
(escluso mod. 33-55, per mod. 410-530 utili 2 velocit)
Pannello PCM con controllo velocit ventilatori, temperatura e
accensione o spegnimento batteria ad acqua o elettrica.
(mod.33-55: 1 velocit, mod. 410-530: utili 2 velocit)
ON
A RICHIESTA
REQUEST
118
ECOM
Dati tecnici
Technical data
MODELLO/Model
u. m.
33
55
110
175
220
255
320
410
m3/h
300
45
0,75
43
33
92x2
4
1
44
F
620
55
1,8
51
55
90x2
4
1
44
F
920
65
2,2
50
110
147x2
4
3
44
F
1.850
77
4,8
52
220
350x2
4
3
44
F
2.250
80
5,2
51
255
350x2
4
3
55
F
2.950
100
8,3
54
320
550x2
4
3
44
F
3.920
100
5
56
410
750x2
4
2
55
F
33
53
1,5
8,3
55
54
3,1
8,5
110
55
4,7
8,8
1.580
70
4,4
53
175
350x2
4
3
44
F
230 / 1 / 50
175
54
7,9
8,5
220
54
9,2
8,5
255
54
11,2
8,5
320
51
13,9
7,8
Pa
A
dB (A)
u. m.
W
No
No
IP
V/ph/Hz
u. m.
%
kW
o
C
530
5130
130
6,6
57,5
530
800X2
4
2
20
F
400/3/50
410
530
57
50
20,6
21,3
9,3
7,5
(1) Valori riferiti alla portata daria nominale vinto il recuperatore e i filtri. / Referred to the nominal air flow after filter and plate heat exchanger
(2) Livello di pressione sonora: valori riferiti ad 1,5 m dallaspirazione della macchina alla portata nominale. Il livello di rumore operativo si discosta in genere dai valori indicati a seconda delle condizioni di funzionamento, del rumore riflesso e del
rumore periferico. / Sound pressure level: data referred to 1,5 mt from inlet in free field. The actual operation noise level generally differs from the values shown in the table , depending on the operation conditions , on the reflected noise and on the
surrounding noise.
(3) Condizioni nominali invernali: aria esterna = - 5 oC BS, UR 80%, aria ambiente: 20 oC BS, UR 80%/Nominal summer conditions: outside air: -5 oC DB, RH 80%, ambient air: 20 oC DB, RH 80%
ECOM
Orientamenti
Configurations
119
ECOM
Prestazioni
Performances
1 mm H2O= 9,8 Pa
Le prestazioni indicate nei diagrammi si riferiscono ad aria alla temperatura di 15o C ed allaltitudine di O mt s.l.m. , e sono state ottenute in installazioni di tipo D in assenza di reti e accessori .
Performance shown in the selection diagrams refer to air at 15o C temperature and 0 mt a.s.l. altitude, and they were obtained in installation type D with no grid nor accessories.
ECOM 33 55
ECOM 110
350
350
300
400
300
55
250
200
33
150
100
50
0
250
200
150
100
max
0
100
150
200
250
300
350
400
450
500
550
600
650
700
200
400
350
300
300
350
250
200
med.
150
max
min.
100
50
800
1000
1200
ECOM 220
250
200
max
150
med.
100
min.
50
0
600
800
1000
1200
1400
1600
500
1800
750
1000
350
1250
1500
1750
2000
2250
ECOM 255
ECOM 320
500
450
300
600
ECOM 175
250
200
max
150
med.
100
min.
50
400
350
300
250
200
150
100
min.
max
med.
50
0
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
500
750
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
ECOM 410
ECOM 530
600
600
med.
min.
50
500
400
300
max
min.
200
100
500
max
400
300
min.
200
100
0
500
1000
1500
2000
2500
3000
3500
4000
4500
500
1000
1500
2000
2500
3000
3500
4000
120
4500
5000
5500
6000
ECOM
Dimensioni
Dimensions
Modello
Model
D1
D2
E1
F1
33
990
290
750
240
79
79
180
55
100
94
55
990
290
750
240
79
79
180
55
220
90
110
1140
410
860
260
95
115
210
100
220
175
1300
500
860
290
77
77
310
95
225
220
1380
500
960
310
87
87
330
85
225
129
255
75
3/4
138
255
1650
600
1230
410
91
91
410
95
288
152
255
162
3/4
160
320
1650
600
1230
410
91
91
410
95
321
135
280
125
3/4
174
410
1750
600
1330
410
116
116
410
95
321
160
280
125
3/4
190
530
1970
700
1400
510
85
85
510
95
321
178
280
225
209
Dimensioni in mm/Dimensions in mm
G1
GAS
kg
100
95
41
90
130
45
115
200
50
3/4
80
109
255
75
3/4
125
ECOM
Accessori
Accessories
BE
u. m.
ECOM 33
ECOM 55
ECOM 110
ECOM 175
ECOM 220
ECOM 255
ECOM 320
ECOM 410
ECOM 530
kW
V
No
No
A
o
C
kg
1,5
230
1
1
6,5
23,3
1,5
3
230
1
1
13
22,2
1,5
3
400
3
1
4,3
17,6
2,5
6
400
3
1
8,65
18,1
2,5
6
400
3
1
8,65
17,5
2,5
12
400
3
1
17,3
22,3
5
12
400
3
1
17,3
19,3
5
12
400
3
1
17,3
16,7
5
18
400
3
1
26
18,6
8
(*) Valori riferiti alle seguenti condizioni: Ting. aria = 8 oC e portata aria nominale / Data referred to T. intake air 8 oC and nominal air flow
BW
u. m.
ECOM 110
ECOM 175
ECOM 220
ECOM 255
ECOM 320
ECOM 410
ECOM 530
kW
8,2
2522
14
2
2,5
33,4
25
8
3/4
2,5
12,2
2522
18
2
2,5
30,8
32
14
3/4
2,5
14,4
2522
18
2
2,5
30,2
30
15
3/4
2,5
20,3
2522
22
2
2,5
33,2
25
17
3/4
5
24,2
2522
22
2
2,5
31,3
33
22
3/4
5
29,9
2522
22
2
2,5
29,7
43
30
3/4
6,5
40,6
2522
22
2
2,5
31,2
38
20
1
9
No
No
mm
o
C
Pa
kPa
GAS
kg
(*) Valori riferiti alle seguenti condizioni: Acqua 70/60 oC; Ting. aria = 8oC; Portata aria nominale / Data referred to the following conditions : Water in/out 70/60 oC; T. intake air 8 oC: Nominal air flow
SEW
Geometria/Geometry
Tubi per rango/Pipes per row
Ranghi/Rows
Passo alette/Fins spacing
RISCALDAMENTO/Heating
Resa termica(1) /Heating capacity(1)
Temperatura uscita aria/Outlet air temperature
Portata acqua / Water flow rate
Perdite di carico acqua / Water pressure drop
Perdite di carico aria / Air pressure drop
RAFFREDDAMENTO/Cooling
Potenza frigorifera (2) / Total cooling capacity(2)
Potenza frigorifera sensibile / Sensibile ooling capacity
Temperatura uscita aria / Outlet air temperature
Portata acqua / Water flow rate
Perdita di carico lato acqua / Water pressure drop
Perdita di carico lato aria / Air pressure drop
u. m.
ECOM 33
ECOM 55
ECOM 110
ECOM 175
ECOM 320
ECOM 410
ECOM 530
no
no
mm
2522
13
3
2,1
2522
13
3
2,1
2522
16
3
2,1
2522
22
3
2,1
2522
25
3
2,1
2522
26
3
2,1
2522
26
3
2,1
2522
26
3
2,1
2522
32
3
2,1
kW
o
C
m3/h
kPa
Pa
4,7
52,8
0,4
3
10
8,2
45,6
0,7
7
13
12
45
1,1
6
27
19,7
43,4
1,7
20
38
23,7
44,5
2,1
34
34
30,5
46,5
2,7
30
25
37
43,7
3,3
43
38
46,2
41,5
4,1
36
50
59,3
41,8
5,2
37
55
kW
kW
o
C
m3/h
kPa
Pa
2
1,3
16,9
0,3
3
20
3,5
2,3
18,7
0,6
7
30
5
3,3
19
0,9
6
38
8,8
5,8
18,9
1,5
21
48
11,1
7,2
18,7
1,9
39
45
14,7
9,4
17,3
2,5
36
35
17,4
11,4
18,3
3,0
49
52
20,9
13,9
19,3
3,6
39
65
26,2
17,4
19,4
4,5
35
62
(1) Valori riferiti a: Ting. aria 8oC, Acqua in/out 70/60 oC; portata aria nominale / Data referred to: T. intake air 8 oC , Water in/out 70/60 oC ; and nominal air flow
(2) Valori riferiti a: Ting. aria 30 oC, UR 50%. Acqua in/out 7/12 oC; portata aria nominale / Date referred to: T. intake air 30 oC, RH 50%. Water in/out 7/12 oC; and nominal air flow.
430
500
600
290
410
500
395 250
450 260
450 290
230
210
310
22
22
22
3/4
3/4
3/4
14
17
21
220
700
500
480
310
330
22
3/4
24
255/320
410
700
700
600
600
660
710
410
410
410
410
22
22
3/4
3/4
29
34
530
700
700
710
510
510
22
42
A
=
1
Aria di rinnovo
Supply air
B
33/55
110
175
1
gas
C
=
peso
weight
kg
1
2
=
Modello
Model
DIMENSIONI/Dimensions SEW
A
B
C
D
E
mm
122
ECOM
Accessori
Accessories
CV3 SELETTORE DI VELOCIT/SPEED CONTROLLER
Adatto per linstallazione a parete, consente di commutare le tre velocit di ventilazione (ad esclusione dei modelli
33, 55 per i quali la velocit unica).
Il C3V presenta i seguenti comandi:
- interruttore off/Raffrescamento/Riscaldamento;
- commutatore a tre posizioni delle velocit (due utili per 410 e 530)
- alimentazione: 230 V
Suitable for wall mounting, it is used to select the three speeds for the ventilation (except for models 33, 55 which
have only one speed).
The C3V features the following controls:
- off/Cooling / Heating switch;
- three-position speed switch (two available for 410 and 530)
- 230 V power supply
ECOM
Parti di ricambio
Spare parts
2
6
123
1 - Ventilatori/fans
2 - Scatola elettrica
Electric box
3 - Scheda elettrica
Control panel
4 - Batteria elettrica o ad
acqua (accessorio)
Electric heater or water
coil (accessory)
5 - Scambiatore di calore
Recovery exchanger
6 - Filtri/filters
7 - Struttura/cabinet