TITLE:

ETPE_ETPA REPLACEMENT
The procedure is made for ETPE_ETPA REPLACEMENT
The contain of procedures are:
1. Preparation
2. Preconditioning
3. Troubleshooting
4. Finishing
1. TANG/HIT
2. SERIAL CABLE / ETHERNET CABLE
3. Anti-static strap
4. Test call equipment
5. Trouble Report Sheet

Objective:

Tools:

Need ETP module Spare (C111826)


ETP plug-in unit (functional unit) and related sw-modules:
- ETP-A (ETPA) = GGNETPAA.IMG
- ETP-A (ETPC) = GGNETPCC.IMG
- ETP (ETPA) = GGNETPAB.IMG
- ETP (ETPE/ETPT) = GGNETPET.IMG
No
I

ACTIVITY
PREPARATION

Check availability permission action or


network interruption from the customer
Tools and replacement modules
availability
Check new ETP card jumper setting &
switch
Wear Anti-static strap

II

PRECONDITIONING

1
2
3

1
2
III
1

Connect Ethernet/ serial cable & login to


BSC.
Record /create activity log
Record all BSC alarms
TROUBLESHOOTING
Check the working unit state ETPE/ETPA
which will be replaced

CHECK

CONDITIONAL

REMARK

OK
OK
OK

See appendix

OK

OK
OK

OK

ZUSI:ETPA; or ZUSI ETPE;


Example: ETPA:0 will be replaced.

Change the unit state of ETPE/ETPA


which will be replaced to SE-NH

Check the interchangeability and DIP


switch settings of the new plug-in unit.
Replace the plug-in unit.
a: disconnect all cable from ETPE / ETPA
which will be replaced. Label it /
remember it. This cable must be connect
in the same port in new ETPE/ETPA.

OK

OK

ZUSC:ETPA,0:BL;
ZUSC:ETPA,0:TE;
ZUSC:ETPA,0:SE;
ZUSC:ETPA,0:SE;
See Appendix 1

OK

b: plug out the faultu ETPE/ETPA


c: insert new ETPE/ETPA & connect the
Company:

PT. NOKIA

Last Update: 24 April 15

cables
5

Change the unit state of ETPE/ETPA into


TE-EX.

OK

ZUSC:ETPA,0:SE;
ZUSC:ETPA,0:TE;

Check the embedded SW version

OK

See appendix 2.1


ZWDM:UT=ETPA,UI=0;

Check ETP SW in OMU Disk

OK

Update the embedded software if needed

OK

See appendix 2.2


Compare result step 6 and step 7 if not
same go to step 8, otherwise go to step
12.
Interogate server IP address for update
embedded SW.
See appendix 2.3
ZQRI:OMU; ZQRI:MCMU;
Choose IP address with attributes LIM
as server.
In this case the IP server is : 10.0.1.12
Update embedded ETPA card
See appendix 2.4
Waiting until flashing completed.

9
10
11
12
13
14
IV
1
2

Check the embedded SW version


After flashing completed, change ACTIVE
mode to STANDBY
Repeat step 8
Run diagnostic unit
Check diagnostic report
If diagnostic report shows that the unit is
healthy, change the state into WO-EX
FINISHING
Test call /check traffic
Keep site clean

OK

See appendix 2.1

OK

See appendix 2.5

OK
OK
OK

ZUDU
ZUDH

OK

ZUSC

OK
OK

Note: If you have trouble during troubleshooting, Please contact Care Engineers
( executors name and signature )

Company:

PT. NOKIA

Last Update: 24 April 15

Appendix 1
ETP C111826
Jumper blocks of the plug-in unit
Figure:
Jumper group of the plug-in unit ETP

Jumpers
Table:
Jumper
1-6
2-5
3-4

Setting
OFF
OFF
OFF

Standard settings of W11


Meaning
Octeon Watchdog is enabled
Baud rate 9600 is selected
Forced boot from FLASH 1 is disabled

DIP-switches
Standard settings
Jumpers for these standard settings are set at the factory, and normally there is no need to change them.
Table:
Interchangeability code settings of ETP
ICC code
Switch settings
1-8
2-7
3-6
4-5
A
OFF
OFF
OFF
OFF
Company:

PT. NOKIA

Last Update: 24 April 15

B
ON
OFF
OFF
C
OFF
ON
OFF
D
ON
ON
OFF
E
OFF
OFF
ON
F
ON
OFF
ON
G
OFF
ON
ON
H
ON
ON
ON
J
OFF
OFF
OFF
K
ON
OFF
OFF
L
OFF
ON
OFF
M
ON
ON
OFF
N
OFF
OFF
ON
P
ON
OFF
ON
R
OFF
ON
ON
Table:
Interchangeability code settings with DIP-switch S1
Switch Default setting Function
1-8
OFF
Interchangeability code bit 0
2-7
OFF
Interchangeability code bit 1
3-6
OFF
Interchangeability code bit 2
4-5
OFF
Interchangeability code bit 3

OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON

Appendix 2
1. Check the embedded SW ETPA/ETPE

ZWDM:UT=<ETP_type>,UI=<index>,MODE=ACTIVE;
ZWDM:UT=<ETP_type>,UI=<index>,MODE=STANDBY;

Example:
ZWDM:UT=ETPA,UI=0,MODE=ACTIVE;
ZWDM:UT=ETPA,UI=0,MODE=STANDBY;

2. Check ETP SW in OMU disk.


ZDDE:OMU:"ZLP:M,MAS;","MXP:W0-LFILES/GGNETPAB.IMG",; (for ETPA)

ZDDE:OMU:"ZLP:M,MAS;","MXP:W0LFILES/GGNETPET.IMG",;(forETPE)
3. Check Server IP address
ZQRI,OMU or ZQRI:MCMU;
Company:

PT. NOKIA

Last Update: 24 April 15

INTERROGATING NETWORK INTERFACE DATA


UNIT
ADMIN
ADDR
INTERFACE STATE MTU ATTR
IP ADDRESS
------------ ----- ----- -------- --------------------------------------------MCMU-0
EL0
UP 1500 LI
(10.1.1.1/24)
LI
(10.0.0.17/29)
EL1
UP 1500 LI
(10.1.1.1/24)
LI
(10.0.0.33/29)
EMB0
UP 1500 LI
(10.1.2.1/27)
EMB1
UP 1500 LI
(10.1.3.1/27)
VLAN20
UP 1500 LIM
(10.0.1.12/26)
->EL0
20 0/0
VLAN201 UP 1500 LIM
(10.0.1.12/26)
->EL1
20 0/0
MCMU-1
EL0

UP

1500 LI
10.1.1.1/24
LI
10.0.0.17/29
EL1
UP 1500 LI
(10.1.1.1/24)
LI
10.0.0.33/29
EMB0
UP 1500 LI
10.1.2.1/27
EMB1
UP 1500 LI
10.1.3.1/27
VLAN20
UP 1500 LIM
10.0.1.12/26
->EL0
20 0/0
VLAN201 UP 1500 LIM
(10.0.1.12/26)
->EL1
20 0/0

4. Update embedded ETPA/ETPE card


ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;
EXAMPLE:
For ETPA :0, SERVER 10.0.1.12
ZWDL:UT=ETPA,UI=0,SERVER=10.10.1.12,SW=W0-LFILES/GGNETPAB.IMG,MODE=STANDBY;
For ETPE:4-0, SERVER 10.0.1.12
ZWDL:UT=ETPE-4,UI=0,SERVER=10.10.1.12,SW=W0-LFILES/GGNETPET.IMG,MODE=STANDBY;

5. Change active mode to standby


ZWDS:UT=<ETP_TYPE>,UI=<INDEX>,PT=<ETP_TYPE>,PI=<INDEX>:;
Example:
ZWDS:UT=ETPA,UI=0,PT=ETP,PI=0:;
Y

Company:

PT. NOKIA

Last Update: 24 April 15