Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
REFRIGERATION AND
AIR CONDITIONING
Contents
General
Electric circuit
Wiring diagram
Voltage range
Cable dimensions
Thermostat connection
Compressor speed
Fan connection
Troubleshooting
LED connection
Protection systems
Page 2
3
3
3
3
4
4
4
4
4
5
BD35F
Technical data
Performance data
6
7
BD35F
(inch)
8
9
BD50F
Technical cata
Performance data
10
11
BD50F
(inch)
12
13
BD80F
Technical data
Performance data
14
15
BD35F
(solar)
16
17
BD35K
(solar)
18
19
Data stamping
Mounting the electronic unit
Connectors
Mounting accessories
Filter drier selection
Sectional view
General
20
21
22
23
24
25
Danfoss variable speed refrigeration compressors type BD35F, BD50F and BD80F are designed for
connection to 12V and 24V DC power supply and for refrigerant R134a (CF3-CH2F).
The compressors are intended especially for use in mobile applications, e.g. cooling boxes, boats,
caravans, trucks, vans, buses, etc. Due to their low energy consumption and the option for a wide
supply voltage range, the compressors are also very suitable for stationary applications powered by
photovoltaic solar panels.
The compressors can be used in refrigerators and freezers designed for capillary tube and TEV as the
throttling device.
The BD35K is especially designed for refrigeration systems using isobutane, refrigerant R600a (C4H10).
R600a is classified as a flammable refrigerant of class A3 according to ANSI/ASHRAE 34. Accordingly,
special safety regulations must be complied with. For domestic appliances a special Test Schedule has
been integrated in the European Standard EN 60335-2-24 and IEC 60335-2-24. For commercial
refrigerators IEC 60335-2-89 will include flammable refrigerants.
The BD35K must only and exclusively be used in appliances certified for R600a according to these or
later regulations. This means that the compressors must not be used in appliances which are not
originally designed and certified for R600a.
This compressor was designed for stationary use only.
The BD compressor concept includes an electronic unit which features overload protection and
battery protection. The electronic unit has internal voltage recording and calibration to the applied
voltage. The electronic unit may also be powered directly from certain types of electronic power
supply units and thus no battery is required.
In addition to being especially quiet in operation, the compressors have a high COP value. They will
operate under continual heeling of 30 such as occurs on boats.
The BD compressors must be mounted in a dry and clean place. The compressors will withstand
storage temperatures down to -35C.
Condensing temperatures:
Max. 60C at stable conditions and max. 70C at peak load.
Ambient temperatures: Min. -10C, max. 55C
CK.46.C7.02
May 2004
Electric circuit
The BD compressors are fitted with a brushless direct current motor which is electronically commutated by an electronic unit.
The electronic unit is delivered separately and must be mounted on the compressor, please see
instructions page 20. The electronic unit must always be connected directly to the battery poles or
power supply unit terminals. For the protection of the installation an external fuse must be installed
in the power supply cable close to the battery or power supply unit. Establish a special wiring for the
BD power supply using direct one-piece cables and avoid to use the existing wiring.
If the chassis is used as a conductor, a proper connection between cable and chassis must be established.
Wrong polarity applied to the electronic unit does not destroy the unit, however, the compressor does
not work.
If the compressor is planned to be stopped for a longer period, a main switch can be installed. The
switch must have a contact system rated min. 20A, otherwise the voltage drop over the contacts will
cause the battery protection to cut off the compressor earlier than intended.
Wiring diagram
BD35K / BD35F Solar
BD35F / BD50F
2
3
6
5
-
4
+
5
6
8380-3
+
+
F
D
1
C
P
T
+
F
D
BD80F
8541
3
6
5
-
8380-4
+
F
D
C
P
T
Voltage range
1: Electronic unit
2: Battery / Solar Panel
3: Fuse
4: Main switch (optional)
5: Fan (optional)
6: LED - Light Emitting Diode (optional)
7: Thermostat
8: Resistor for presetting speed (optional)
9: Resistor for presetting battery protection
voltage (optional)
BD35/50/80F: 12V systems: From 10.4V (9.6V) to 17V; 24V systems: From 22.8V (21.3V) to 31.5V.
BD35F/BD35K: Solar systems: 10V - 45V
The low voltage limits stated in brackets () can be established if a connection is made between the
terminals C and P, please see also the passage Optional battery protection settings page 5.
The electronic unit will calibrate to the applied voltage. This means that if the battery voltage is less
than 17V, the electronic unit assumes that it is working in a 12V system. If the voltage is higher than 17V,
the electronic unit assumes that it is working in a 24V system. Consequently, the compressor does not
run at power supply voltages between about 17V and the desired battery protection cut-out voltage
for 24V systems.
A continuous voltage range from 9.6V to 31.5V can be established if a 220k resistor (wiring diagram
item 9) is connected between the terminals C and P. This wide voltage range makes the BD compressors very suitable for photovoltaic powering.
Cable dimensions
To ensure correct start and operating conditions, the following cable dimensions must be observed:
BD35F / BD50F / BD35K Solar / BD35F Solar
Cross
section
mm 2
2.5
4
6
10
5
8
12
20
BD80F
Cross
section
mm2
2.5
CK.46.C7.02
Thermostat connection
BD compressors can operate with normal mechanical type thermostats as used in refrigeration appliances, or with electronic thermostats. Always use new thermostats.
The thermostat is connected between the terminals C and T of the electronic unit.
The compressor current does not flow through the thermostat contacts.
When the thermostat is cut out there will still be power on to the electronic unit.
A system with no stand-by power consumption can be established if the thermostat (7) is replaced by
a jumper between the terminals C and T, and the main switch (4) is replaced by a thermostat. In this
case the full current to the compressor flows through the thermostat, which must be rated accordingly.
Compressor speed
Without any resistor in the control circuit, the compressor will run with a fixed speed of 2,000 rpm
when the thermostat is switched on, depending on the electronic unit version (see tables below).
Other fixed speeds in the range between 2,000 and
3,500/4,400rpm can be obtained when a resistor (8)
BD80F
is installed to adjust the current (mA) of the contol
Electronic Resistor
Motor Contr.circ.
circuit, please see wiring diagrammes page 3.
unit
80
02 EO
N
1 A
10 with
BD35F / BD50F
Electronic
unit
10
02 220
N
1 0
10 01N
1
00
03 EO
N
1 A
10 with
LED connection
Resistor
R1 (8)
0
277
692
1523
0
173
450
865
1696
Motor
speed
rpm
2,000
2,500
3,000
3,500
AEO
2,000
2,500
3,000
3,500
Contr.circ.
current
mA
5
4
3
2
6
5
4
3
2
R1 (8)
0
203
451
867
1700
speed
rpm
AEO
2,500
3,100
3,800
4,400
current
mA
6
5
4
3
2
10 with
Resistor
R1 (8)
0
173
450
865
1696
Motor
speed
rpm
AEO
2,000
2,500
3,000
3,500
Contr.circ.
current
mA
6
5
4
3
2
A 10mA Light Emitting Diode (LED) for compressor operation monitoring can be connected between
the terminals + and D.
Operational errors will cause the LED to flash a number of times. The number of flashes depends on
what kind of operational error was recorded.
Each flash will last second. After the actual number of flashes there will be a delay with no flashes,
so that the sequence for each error recording is repeated every 4 seconds.
Operational errors shown by LED (optional):
BD35F / BD50F / BD35K Solar / BD35F Solar
Number
of
flashes
Error type
CK.46.C7.02
BD80F
Number
of
flashes
Error type
May 2004
Fan connection
Troubleshooting
Protection systems
The BD compressor protection system facilitates protection against compressor overload and start
failure, fan overload and electronic unit overheating as well as destructive battery discharge.
When an overload protection is activated, the compressor enters a cycle in which it makes start
attempts at about 60 seconds intervals until a successfull start is achieved.
Overload protections
The compressor overload and start protection cuts off power to the compressor if the compressor
speed drops below approximately 1,850 rpm (BD35F/BD50F/BD35K) or 2,450 rpm (BD80F) or this
motor speed is not reached during the start sequence. Possible reasons for overload protection
activating could be excess refrigeration system pressures during operation or too high pressure
difference. The fan overload protection stops the compressor and fan if the fan current exceeds
0.5Aaverage or 1Apeak .
An overheating of the electronic unit heat sink will cause the compressor to stop. Restart will occur
automatically when the temperature has dropped.
If a fan is installed, it will continue to run if the compressor stops due to overload or electronic unit
overheating.
Voltage protection
If a voltage outside the specified range is applied to the electronic unit, the compressor does not start,
or it stops if the voltage limit is exceeded during operation. The compressor will restart automatically
about 1 minute after the supply voltage has reached the reset voltage within the range in question.
If a fan is installed, it will start to operate without a delay as soon as the reset voltage is reached.
Battery protection
(BD35F / BD50F / BD80F)
To ensure sufficient battery power for proper compressor operation or to avoid permanent damage to
the battery because of heavy discharge, the BD electronic unit facilitates also a battery protection.
The compressor is stopped and restarted again according to the decided voltage limits measured on
the + and - terminals of the electronic unit.
Standard battery protection settings
12V cut-out
V
10.4
12V cut-in
V
11.7
24V cut-out
V
22.8
24V cut-in
V
24.2
Other battery protection settings are optional if a connection, which includes a resistor, is established
between terminals C and P, please see the wiring diagram page 3.
Optional battery protection settings
Resistor (R9)
k
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220
May 2004
12V cut-out
V
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6
12V cut-in
V
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9
CK.46.C7.02
12V max.
voltage
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
24V cut-out
V
21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6
24V cut-in
V
22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0
24V max.
voltage
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
BD35F
Direct Current Compressor
R134a
12 - 24V
Data Sheet (Replaces CD.46.A7.02)
Code numbers
101Z0200
BD35F
101Z
Application
R134a
Blue stripe
N 1297
Barcode on
white background
Application
Application
LBP/MBP/(HBP)
0200
MADE IN GERMANY
Grey background
-30 to 0 (10)
12 - 24V DC / 31.5V DC
0277 00
* depending on application
Design
Displacement
cm
2.00
Oil quantity
cm 3
150
300
cm3
870
kg
4.3/0.25
EC approval mark
(electronic unit)
S
O
F1
F2
Motor
Motor type
Approvals
THERMALLY
PROTECTED
SYSTEM
Approval mark
Variable speed
BD35F
12/24V DC
e4
55
S or F1*
43C
8369-7
8415
8369
204
170
2.3
E4 72/245 95/54 0277 00, UL984, CSA-C22.2
Dimensions
137
135
128
B2
73
Suction connector
location/I.D. mm
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
April 2004
[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6
[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9
70
100
B1 B A
20
CK.46.C7.02
201
8269
16
105
[k]
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220
B2
127
150
28
130
pcs.
4.2
46
Compressors on a pallet
16
59
A
B
B1
78.5
mm
120
Height
123
May 2004
-30
15.8
20.2
22.5
26.2
-25
23.9
29.9
32.4
35.9
watt
-23.3
26.9
33.5
36.5
40.4
-20
33.1
41.2
45.4
50.5
-15
43.8
54.6
61.8
69.8
-10
56.6
70.7
81.7
93.6
-5
71.7
89.7
105
122
0
89.9
112
133
5
111
139
-23.3
33.1
41.3
44.9
49.7
-20
40.7
50.7
55.9
62.2
-15
54.0
67.3
76.1
86.0
-10
69.8
87.1
101
115
-5
88.6
111
130
150
0
111
139
164
5
137
172
10
136
Terminal plug
Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
-30
19.5
24.9
27.7
32.2
watt
-25
29.4
36.8
39.9
44.2
10
169
8236-2
Power consumption
rpm \ C
2,000
2,500
3,000
3,500
-30
17.6
23.3
29.9
36.0
watt
-25
23.4
30.9
36.0
42.8
-23.3
25.3
33.3
38.3
45.4
-20
28.7
37.8
43.0
50.8
-15
33.6
44.1
50.7
59.5
-10
38.3
50.2
58.7
68.9
-5
43.0
56.2
66.8
78.5
0
48.0
62.3
74.8
5
53.4
68.7
10
59.5
-30
1.5
1.9
2.5
3.0
-25
2.0
2.6
3.0
3.6
-23.3
2.1
2.8
3.2
3.8
-20
2.4
3.2
3.6
4.3
-15
2.8
3.7
4.2
5.0
-10
3.2
4.2
4.9
5.7
-5
3.6
4.7
5.6
6.5
0
4.0
5.2
6.2
5
4.5
5.8
-30
0.90
0.87
0.75
0.73
-30
1.10
1.07
0.93
0.89
LED -
Fan
R1
Thermostat
R2
+
F
D
C
P
T
W/W
-25
1.02
0.97
0.90
0.84
-23.3
1.06
1.01
0.95
0.89
-20
1.15
1.09
1.06
1.00
-15
1.31
1.24
1.22
1.17
-10
1.48
1.41
1.39
1.36
-5
1.67
1.60
1.58
1.55
0
1.87
1.80
1.78
5
2.08
2.02
-25
1.25
1.19
1.11
1.03
-23.3
1.31
1.24
1.17
1.09
-20
1.42
1.34
1.30
1.23
-15
1.61
1.53
1.50
1.44
-10
1.82
1.74
1.72
1.68
-5
2.06
1.97
1.95
1.91
0
2.31
2.23
2.20
5
2.57
2.50
10
2.29
COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
Power supply
10
5.0
Main switch
Fuse
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 12V DC
1 Watt = 0.86 kcal/h
EN 12900/CECOMAF
55C
32C
55C
ASHRAE
55C
32C
32C
Accessories
Devices
Compressor speed
Electronic Resistor
unit
(R1)
0
0
1
277
02 220
N
1 0
692
10 01N
1523
1
0
173
00
3
0 EO
450
1N A
865
10 with
1696
Motor
speed
rpm
2,000
2,500
3,000
3,500
AEO
2,000
2,500
3,000
3,500
10
2.84
Contr.circ.
current
mA
5
4
3
2
6
5
4
3
2
Number
of
flashes
Error type
BD35F
Wire dimensions
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
section
Gauge
mm2
ft.
ft.
12
12
10
8
2.5
4
6
10
8
13
19.5
32.8
2.5
4
6
10
16
26
39
65.6
5
8
12
20
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
May 2004
CD.46.A8.02
CK.46.C7.02
April 2004
BD35F
101Z
Application
R134a
Blue stripe
N 1297
Application
LBP/MBP/ [HBP]
Barcode on
white background
Grey background
Application
Evaporating temperature range
F (C)
12 - 24V DC / 31.5V DC
F (C)
131 (55)
Design
Displacement
cu.in. (cm3)
0.12 (2.00)
Oil quantity
fl.oz. (cm3)
5.1 (150)
oz. (g)
10.5 (300)
fl.oz. (cm3)
0277 00
EC approval mark
(electronic unit)
29.6 (870)
S
O
F1
9.5/0.55 (4.3/0.25)
Motor
Motor type
Variable speed
BD35F
12/24V DC
e4
S or F1*
* depending on application
8415
0204
MADE IN GERMANY
F2
THERMALLY
PROTECTED
SYSTEM
8369-7
8369-3
Approval mark
2.3
0.63"(16)
5.39 (137)
5.32 (135)
5.04 (128)
B2
2.87 (73)
Suction connector
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
E 0.202-0.205 (5.0+0.12/0.20)
Compressors on a pallet
pcs.
1.81" (46)
A
B
B1
2.32"(59)
in. (mm)
4.13"(105)
Height
5.12"(130)
Dimensions
1.10" (28)
4.84"(123)
150
5.00"(127)
[k]
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220
April 2004
[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6
[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9
Voltage
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
[V]
21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6
[V]
22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0
Voltage
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
CD.46.C2.22
CK.46.C7.02
B1 B A
B2
7.91"(201)
8269-2
8.03"(204)
6.70"(170)
0.63"(16)
2.76"(70)
3.94"(100)
0.79"(20)
3.09"(78.5)
4.72"(120)
0.17"(4.2)
0.35"(9)
May 2004
Capacity (ASHRAE)
rpm \ F
2,000
2,500
3,000
3,500
-20
74
95
104
119
-13
101
127
138
153
Btu/h
-10
113
142
155
171
0
159
199
222
248
10
214
268
307
349
20
280
351
410
473
30
361
452
535
619
40
458
573
681
45
514
643
10
50.6
63.2
72.4
82.5
20
66.4
83.0
97.0
112
30
85.5
107
126
147
40
109
136
161
45
122
152
50
575
Terminal plug
-20
17.5
22.2
24.5
27.9
-13
23.9
29.9
32.4
35.9
-10
26.8
33.4
36.4
40.3
0
37.6
46.9
52.3
58.5
watt
50
136
8236-2
Power consumption
rpm \ F
2,000
2,500
3,000
3,500
-20
19.1
25.2
31.0
37.5
-13
23.5
31.0
35.8
42.9
watt
-10
25.3
33.3
38.0
45.4
0
30.8
40.7
45.9
54.5
10
36.1
47.4
54.5
64.4
20
41.3
54.0
63.4
74.9
30
46.6
60.7
72.2
85.7
40
52.5
67.7
80.6
45
55.7
71.5
50
59.1
-20
1.59
2.10
2.61
3.14
-13
1.96
2.58
3.01
3.58
-10
2.10
2.77
3.19
3.79
0
2.57
3.38
3.86
4.55
10
3.01
3.95
4.58
5.38
20
3.44
4.49
5.32
6.25
30
3.89
5.05
6.06
7.15
40
4.37
5.63
6.76
45
4.64
5.95
rpm \ F
2,000
2,500
3,000
3,500
-20
3.87
3.75
3.36
3.16
-13
4.29
4.09
3.86
3.56
-10
4.48
4.26
4.07
3.77
0
5.16
4.89
4.83
4.56
10
5.93
5.64
5.63
5.42
20
6.80
6.50
6.48
6.31
30
7.74
7.45
7.41
7.23
40
8.73
8.47
8.44
45
9.23
8.99
-20
0.92
0.89
0.79
0.75
0
1.22
1.15
1.13
1.07
10
1.40
1.33
1.32
1.28
20
1.60
1.53
1.52
1.49
30
1.82
1.76
1.74
1.70
40
2.06
2.00
1.98
45
2.17
2.12
-13
1.02
0.97
0.90
0.84
-10
1.06
1.01
0.96
0.89
Fan
+
F
D
C
P
T
R2
50
9.73
W/W
50
2.29
Electronic Resistor
unit
(R1)
0
0
1
277
02 220
1N 0
692
10 01N
1523
1
0
173
00
3
0 EO
450
1N A
865
10 with
1696
Motor
speed
rpm
2,000
2,500
3,000
3,500
AEO
2,000
2,500
3,000
3,500
Contr.circ.
current
mA
5
4
3
2
6
5
4
3
2
Test conditions
ASHRAE
Condensing temperature
130F (54,4C)
Ambient & suction gas temp. 90F (32C)
Liquid temperature
90F (32C)
Static cooling, 12V DC
1 Watt = 3.41 Btu/h = 0.86 kcal/h
Number
of
flashes
Error type
section
Gauge
mm2
ft.
ft.
12
12
10
8
2.5
4
6
10
8
13
19.5
32.8
2.5
4
6
10
16
26
39
65.6
5
8
12
20
Accessories
Devices
BD35F
CD.46.C2.22
CK.46.C7.02
EN 12900
55C (131F)
32C (90F)
55C (131F)
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
Compressor speed
May 2004
LED -
Btu/Wh
Wire dimensions
R1
Power supply
50
4.93
Thermostat
EER (ASHRAE)
Main switch
Fuse
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
April 2004
BD50F
Direct Current Compressor
R134a
12 - 24V
Data Sheet (Replaces CD.46.B5.02)
Code numbers
101Z1220
BD50F
101Z
Application
R134a
Blue stripe
N 1297
Barcode on
white background
Application
Application
LBP/MBP/(HBP)
1220
MADE IN GERMANY
Grey background
-30 to 0 (10)
12 - 24V DC / 31.5V DC
0277 00
* depending on application
Design
Displacement
cm
2.50
Oil quantity
cm 3
150
300
cm3
870
kg
4.3/0.25
EC approval mark
(electronic unit)
S
O
F1
F2
Motor
Motor type
THERMALLY
PROTECTED
SYSTEM
Approval mark
Variable speed
BD50F
12/24V DC
e4
55
S or F1*
43C
8369-8
8415
8369-2
204
170
2.0
E4 72/245 95/54 0277 00, UL984, CSA-C22.2
Dimensions
137
135
128
B2
73
Suction connector
location/I.D. mm
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
pcs.
16
127
B1 B A
20
Resistor (R2) 12V cut-out 12V cut-in 12V max. 24V cut-out 24V cut-in 24V max.
April 2004
10
Voltage
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
[V]
21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6
[V]
22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0
Voltage
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
CD.46.B6.02
CK.46.C7.02
201
8269
16
46
[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9
105
[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6
B2
28
130
150
4.2
59
Compressors on a pallet
70
100
A
B
B1
78.5
mm
120
Height
123
May 2004
-30
20.1
27.0
31.0
38.1
-25
31.0
39.0
45.4
53.2
watt
-23.3
34.9
43.4
50.6
59.1
-20
42.8
52.7
61.5
71.9
-15
56.3
68.9
80.7
95.0
-10
72.2
88.9
104
124*
-5
91.6
113
134*
159*
0
115
144*
171*
5
144*
181*
-23.3
43.1
53.6
62.5
72.9
-20
52.9
65.0
75.9
88.7
-15
69.5
85.1
100
117
-10
89.3
110
129
153*
-5
113
140
166*
196*
0
143
178*
212*
5
178*
224*
Terminal plug
Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
-30
24.7
33.3
38.2
47.0
-25
38.3
48.1
56.0
65.7
10
178*
watt
10
221*
8236-2
Power consumption
rpm \ C
2,000
2,500
3,000
3,500
-30
25.1
34.1
39.9
50.2
-25
31.8
40.5
49.2
59.3
watt
-23.3
34.0
42.9
52.2
62.5
-20
38.2
47.8
57.8
69.0
-15
44.7
55.8
66.5
80.2
-10
51.3
64.7
76.4
93.4*
-5
58.3
74.3
88.4*
109*
0
65.8
84.8*
104*
5
74.2*
96.1*
10
83.5*
-30
2.2
2.9
3.5
4.2
-25
2.6
3.4
4.2
4.9
-23.3
2.8
3.6
4.4
5.2
-20
3.1
4.0
4.9
5.8
-15
3.8
4.7
5.6
6.7
-10
4.4
5.4
6.5
7.8*
-5
5.1
6.2
7.4*
9.0*
0
5.8
7.0*
8.5*
5
6.4*
7.8*
rpm \ C
2,000
2,500
3,000
3,500
-30
0.80
0.79
0.78
0.76
-30
0.99
0.98
0.96
0.94
LED -
Fan
R1
R2
+
F
D
C
P
T
W/W
-25
0.98
0.96
0.92
0.90
-23.3
1.03
1.01
0.97
0.95
-20
1.12
1.10
1.06
1.04
-15
1.26
1.24
1.21
1.19
-10
1.41
1.37
1.37
1.32*
-5
1.57
1.53
1.51*
1.45*
0
1.75
1.70*
1.65*
5
1.94*
1.88*
-25
1.21
1.19
1.14
1.11
-23.3
1.27
1.25
1.20
1.17
-20
1.38
1.36
1.31
1.28
-15
1.56
1.53
1.50
1.46
-10
1.74
1.70
1.69
1.64*
-5
1.94
1.89
1.87*
1.80*
0
2.16
2.10*
2.04*
5
2.40*
2.33*
COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
Power supply
10
6.9*
Thermostat
Main switch
Fuse
10
2.13*
W/W
10
2.65*
Test conditions
EN 12900/CECOMAF
ASHRAE
Condensing temperature
55C
55C
Ambient and suction gas temp.
32C
32C
Liquid temperature
55C
32C
Static cooling, 12V DC
* Fan cooling of electronic unit compulsory
Accessories
1 Watt = 0.86 kcal/h
Compressor speed
Electronic Resistor
Motor Contr.circ.
unit
(R1)
speed
current
rpm
mA
0
2,000
5
0
1
277
2,500
4
02 0
N 022
1
692
3,000
3
10 01N
1523
3,500
2
1
0
AEO
6
173
2,000
5
00
3
0 O
450
2,500
4
N AE
1
865
3,000
3
10 with
1696
3,500
2
In AEO (Adaptive Energy Optimizing) speed
mode the BD compressor will always adapt
its speed to the actual cooling demand.
Devices
Number
of
flashes
Error type
BD50F
Wire dimensions
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
section
Gauge
mm2
ft.
ft.
12
12
10
8
2.5
4
6
10
8
13
19.5
32.8
2.5
4
6
10
16
26
39
65.6
5
8
12
20
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
May 2004
CD.46.B6.02
CK.46.C7.02
April 2004
11
BD50F
101Z
Application
R134a
Blue stripe
N 1297
Application
LBP/MBP/ [HBP]
Barcode on
white background
Grey background
Application
Evaporating temperature range
F (C)
12 - 24V DC / 31.5V DC
F (C)
131 (55)
Design
Displacement
cu.in. (cm3)
0.15 (2.50)
Oil quantity
fl.oz. (cm3)
5.1 (150)
oz. (g)
10.5 (300)
fl.oz. (cm3)
0277 00
EC approval mark
(electronic unit)
29.6 (870)
S
O
F1
9.5/0.55 (4.3/0.25)
Motor
Motor type
Variable speed
BD50F
12/24V DC
e4
S or F1*
* depending on application
8415
0203
MADE IN GERMANY
F2
THERMALLY
PROTECTED
SYSTEM
8369-8
8369-4
Approval mark
2.0
0.63"(16)
5.39 (137)
5.32 (135)
5.04 (128)
B2
2.87 (73)
Suction connector
0.252-0.259 (6.50.09)
Process connector
0.252-0.259 (6.50.09)
Discharge connector
E 0.202-0.205 (5.0+0.12/0.20)
Compressors on a pallet
pcs.
1.81" (46)
A
B
B1
2.32"(59)
in. (mm)
4.13"(105)
Height
5.12"(130)
Dimensions
1.10" (28)
4.84"(123)
150
5.00"(127)
[k]
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220
April 2004
12
[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6
[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9
Voltage
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
[V]
21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6
[V]
22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0
Voltage
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
CD.46.D2.22
CK.46.C7.02
B1 B A
B2
7.91"(201)
8269-2
8.03"(204)
6.70"(170)
0.63"(16)
2.76"(70)
3.94"(100)
0.79"(20)
3.09"(78.5)
4.72"(120)
0.17"(4.2)
0.35"(9)
May 2004
Capacity (ASHRAE)
rpm \ F
2,000
2,500
3,000
3,500
-20
95
119
142
167
-13
126
157
189
220
Btu/h
-10
142
176
211
245
0
201
247
296
342
10
273
335
401
464
20
359
442
529
612*
30
458
570
682*
790*
40
570
723*
863*
45
632*
809*
10
64. 9
79.3
95.2
11 0
20
85.2
105
125
145*
30
109
135
161*
187*
40
135
171*
204*
45
150*
191*
50
697*
Terminal plug
-20
22.6
28.2
33.7
39.8
-13
30.0
37.3
44.8
52.2
-10
33.6
41.7
50.1
58.2
0
47.7
58. 5
70.4
81.3
watt
50
165*
8236-2
Power consumption
rpm \ F
2,000
2,500
3,000
3,500
-20
27.4
34.3
41.4
49.6
-13
32.5
41.4
50.1
58.8
watt
-10
34.6
44.3
53.7
62.6
0
41.7
54.0
65.2
75.5
10
49.0
63.4
76.2
88.7
20
56.8
73.0
87.4
103*
30
65.4
82.8
98.9*
119*
40
75.1
93.1*
111*
45
80.4*
98.6*
50
86.2*
-20
2.28
2.86
3.52
4.20
-13
2.69
3.41
4.16
4.88
-10
2.87
3.65
4.43
5.18
0
3.50
4.45
5.37
6.24
10
4.18
5.26
6.33
7.39
20
4.90
6.10
7.31
8.61*
30
5.65
6.94
8.32*
9.91*
40
6.45
7.81*
9.34*
45
6.87*
8.25*
rpm \ F
2,000
2,500
3,000
3,500
-20
3.49
3.47
3.43
3.37
-13
3.89
3.81
3.77
3.74
-10
4.09
3.97
3.93
3.91
0
4.81
4.58
4.55
4.54
10
5.57
5.28
5.26
5.23
20
6.31
6.05
6.05
5.94*
30
7.00
6.88
6.89*
6.66*
40
7.60
7.76*
7.76*
45
7.85*
8.21*
-20
0.82
0.82
0.81
0.80
0
1.13
1.08
1.07
1.07
10
1.31
1.24
1.24
1.23
20
1.48
1.42
1.42
1.40*
30
1.64
1.62
1.62*
1.56*
40
1.78
1.82*
1.82*
45
1.84*
1.93*
-13
0.92
0.90
0.89
0.88
-10
0.96
0.94
0.93
0.92
50
8.09*
W/W
50
1.90*
Fan
+
F
D
C
P
T
R2
Electronic Resistor
unit
(R1)
0
0
1
277
02 220
1N 0
692
10 01N
1523
1
0
173
00
3
0 EO
450
1N A
865
10 with
1696
Motor
speed
rpm
2,000
2,500
3,000
3,500
AEO
2,000
2,500
3,000
3,500
Contr.circ.
current
mA
5
4
3
2
6
5
4
3
2
Test conditions
ASHRAE
Condensing temperature
130F (54,4C)
Ambient & suction gas temp. 90F (32C)
Liquid temperature
90F (32C)
Static cooling, 12V DC
* Fan cooling of electronic unit compulsory
1 Watt = 3.41 Btu/h = 0.86 kcal/h
Number
of
flashes
Error type
section
Gauge
mm2
ft.
ft.
12
12
10
8
2.5
4
6
10
8
13
19.5
32.8
2.5
4
6
10
16
26
39
65.6
5
8
12
20
Accessories
Devices
BD50F
CD.46.D2.22
CK.46.C7.02
EN 12900
55C (131F)
32C (90F)
55C (131F)
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
Compressor speed
May 2004
LED -
Btu/Wh
Wire dimensions
R1
Power supply
50
7.29*
Thermostat
EER (ASHRAE)
Main switch
Fuse
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
April 2004
13
BD80F
Direct Current Compressor
R134a
12 - 24V
Data Sheet (Replaces (CD.46.F1.02)
Code numbers
101Z0280
BD80F
Application
R134a
Blue stripe
Application
101Z
Application
N 1297
LBP
-30 to -5
Barcode on
white background
12 - 24V DC / 31.5V DC
Grey background
MADE IN GERMANY
e4
43
S or F1*
43C
0277 00
EC approval mark
* depending on application
Design
Displacement
cm 3
3.00
Oil quantity
cm 3
150
300
cm3
870
kg
4.3/0.3
0280
8369-6
8415
S
O
F1
F2
Motor
Motor type
Variable speed
2.0
204
170
mm
A
B
B1
137
135
128
B2
73
Suction connector
location/I.D. mm
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
Compressors on a pallet
pcs.
100
Height
70
100
Dimensions
16
4.2
127
150
B1 B A
B2
15
May 2004
14
[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9
Voltage
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
[V]
21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6
[V]
22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0
Voltage
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
CD.46.F2.02
CK.46.C7.02
209
8539
16
46
[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6
108
[k]
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220
34
130
59
134
131
May 2004
-30
35.3
41.8
49.6
54.8
watt
-25
49.5
59.0
70.5
78.0
-23.3
55.0
65.6
78.5
86.7
-20
66.6
79.6
95.3
105
-15
87.1
104
125
138
-10
112
133
159
176
-5
140
168
200
221
-25
61.1
72.8
87.0
96.1
-23.3
67.8
80.9
96.8
107
-20
82.2
98.2
118
130
-15
108
129
154
170
-10
138
165
197
218
-5
174
207
248
274
Capacity (ASHRAE)
rpm \ C
2,500
3,100
3,800
4,400
-30
43.5
51.5
61.1
67.6
Terminal plug
watt
8540
Power consumption
r pm \ C
2,500
3,100
3,800
4,400
-30
40.0
48.7
59.5
69.0
watt
-25
50.0
61.2
75.0
87.0
-23.3
53.4
65.4
80.2
93.0
-20
60.3
73.8
90.3
105
-15
71.3
87.0
106
123
-10
83.1
101
124
144
-5
96
118
145
168
-30
3.3
4.1
5.0
5.8
-25
4.2
5.1
6.3
7.2
-20
5.0
6.1
7.5
8.7
-15
5.9
7.2
8.9
10.3
-10
6.9
8.5
10.3
12.0
-5
8.0
9.8
12.1
14.0
-25
0.99
0.96
0.94
0.90
-23.3
1.03
1.00
0.98
0.93
-20
1.10
1.08
1.06
1.01
-15
1.22
1.20
1.17
1.12
-10
1.34
1.31
1.28
1.22
-5
1.46
1.42
1.39
1.32
-25
1.22
1.19
1.16
1.11
-23.3
1.27
1.24
1.21
1.15
-20
1.36
1.33
1.30
1.24
-15
1.51
1.48
1.45
1.38
-10
1.66
1.62
1.59
1.51
-5
1.81
1.76
1.71
1.63
-30
0.88
0.86
0.83
0.79
-30
1.09
1.06
1.03
0.98
Cross
section
mm2
Compressor speed
02 EO
1N A
10 with
0
203
451
867
1700
Motor
speed
rpm
Contr.circ.
current
mA
AEO
2,500
3,100
3,800
4,400
6
5
4
3
2
May 2004
LED -
Fan
R1
Thermostat
R2
+
F
D
C
P
T
Error type
2.5
80
W/W
Test conditions
EN 12900/CECOMAF
ASHRAE
Condensing temperature
55C
55C
Ambient and suction gas temp.
32C
32C
Liquid temperature
55C
32C
Static cooling, 12V DC
Fan cooling of electronic unit integrated
Wire dimensions
1 Watt = 0.86 kcal/h
Electronic Resistor
(R1)
unit
Power supply
W/W
COP (ASHRAE)
r pm \ C
2,500
3,100
3,800
4,400
-23.3
4.5
5.5
6.7
7.7
Main switch
Fuse
Accessories
Devices
BD80F
CD.46.F2.02
CK.46.C7.02
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 2,450 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
May 2004
15
BD35F
Direct Current Compressor for Solar Applications
R134a
10 - 45V
Data Sheet
Code numbers
BD35F without electronic unit
BD35F
101Z0210
101Z
Application
Application
Barcode on
white background
Application
LBP/MBP/(HBP)
MADE IN GERMANY
Grey background
-30 to 0 (10)
e4
10 - 45V DC
Fan output
0277 00
EC approval mark
55
43C
S or F1*
S
O
F1
* depending on application
Design
Displacement
cm 3
Oil quantity
cm 3
150
300
0210
8369-5
Blue stripe
8415
F2
2.00
cm3
870
kg
4.3/0.25
204
170
Variable speed
2.3
70
100
Motor type
78.5
Motor
16
Dimensions
A
B
B1
B2
73
location/I.D. mm
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
B1 B A
B2
201
150
8269
16
28
July 2003
16
CD.46.E1.02
CK.46.C7.02
130
59
46
105
pcs.
137
135
128
Suction connector
Compressors on a pallet
127
20
mm
120
Height
4.2
123
May 2004
-30
15.8
20.2
22.5
26.2
-25
23.9
29.9
32.4
35.9
watt
-23.3
26.9
33.5
36.5
40.4
-20
33.1
41.2
45.4
50.5
-15
43.8
54.6
61.8
69.8
-10
56.6
70.7
81.7
93.6
-5
71.7
89.7
105
122
0
89.9
112
133
5
111
139
-23.3
33.1
41.3
44.9
49.7
-20
40.7
50.7
55.9
62.2
-15
54.0
67.3
76.1
86.0
-10
69.8
87.1
101
115
-5
88.6
111
130
150
0
111
139
164
5
137
172
-23.3
25.3
33.3
38.3
45.4
-20
28.7
37.8
43.0
50.8
-15
33.6
44.1
50.7
59.5
-10
38.3
50.2
58.7
68.9
-5
43.0
56.2
66.8
78.5
0
48.0
62.3
74.8
5
53.4
68.7
10
59.5
5
4.5
5.8
10
5.0
Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
-30
19.5
24.9
27.7
32.2
-25
29.4
36.8
39.9
44.2
-30
17.6
23.3
29.9
36.0
-25
23.4
30.9
36.0
42.8
10
169
-30
1.5
1.9
2.5
3.0
-25
2.0
2.6
3.0
3.6
-23.3
2.1
2.8
3.2
3.8
-20
2.4
3.2
3.6
4.3
-15
2.8
3.7
4.2
5.0
-10
3.2
4.2
4.9
5.7
-5
3.6
4.7
5.6
6.5
Solar panel
-30
0.90
0.87
0.75
0.73
-30
1.10
1.07
0.93
0.89
Main switch
+
LED -
Fan
W/W
-25
1.02
0.97
0.90
0.84
-23.3
1.06
1.01
0.95
0.89
-20
1.15
1.09
1.06
1.00
-15
1.31
1.24
1.22
1.17
-10
1.48
1.41
1.39
1.36
-5
1.67
1.60
1.58
1.55
0
1.87
1.80
1.78
5
2.08
2.02
-25
1.25
1.19
1.11
1.03
-23.3
1.31
1.24
1.17
1.09
-20
1.42
1.34
1.30
1.23
-15
1.61
1.53
1.50
1.44
-10
1.82
1.74
1.72
1.68
-5
2.06
1.97
1.95
1.91
0
2.31
2.23
2.20
5
2.57
2.50
+
+
F
D
C
R1
COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
Fuse
0
4.0
5.2
6.2
8236-3
watt
Terminal plug
watt
Power consumption
rpm \ C
2,000
2,500
3,000
3,500
10
136
Thermostat
10
2.29
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 12V DC
1 Watt = 0.86 kcal/h
EN 12900/CECOMAF
55C
32C
55C
ASHRAE
55C
32C
32C
Accessories
Devices
Compressor speed
Electronic Resistor
Motor Contr.circ.
unit
(R1)
speed
current
rpm
mA
0
AEO
6
00
173
2,000
5
04 EO
450
2,500
4
1N h A
0
865
3,000
3
1 wit
1696
3,500
2
In AEO (Adaptive Energy Optimizing) speed
mode the BD compressor will always adapt
its speed to the actual cooling demand.
10
2.84
BD35F
Not
deliverable
from Danfoss
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap on in quantities
118-1917
118-1918
118-1919
Number
of
flashes
Error type
Wire dimensions
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
section
Gauge
mm2
ft.
ft.
12
12
10
8
2.5
4
6
10
8
13
19.5
32.8
2.5
4
6
10
16
26
39
65.6
5
8
12
20
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
May 2004
CD.46.E1.02
CK.46.C7.02
July 2003
17
BD35K
Direct Current Compressor for Solar Applications
(for stationary use only)
R600a
10 - 45V
Data Sheet
Code numbers
BD35K without electronic unit
BD35K
101Z0211
101Z
Application
R600a
N 1297
Application
Barcode on
white background
Application
LBP/MBP/(HBP)
0211
8525
MADE IN GERMANY
Grey background
-30 to 0 (10)
10 - 45V DC
Fan output
55
43C
Design
Displacement
cm 3
Oil quantity
cm 3
R600a
S or F1*
3.00
8122
e4
150
120
0277 00
cm3
870
EC approval mark
kg
4.3/0.25
8415
204
170
Motor
Variable speed
1.8
70
100
78.5
Motor type
16
location/I.D. mm
A
B
B1
B2
73
6.2 0.09
Process connector
location/I.D. mm
6.2 0.09
Discharge connector
location/I.D. mm
5.0 +0.12/+0.20
Compressors on a pallet
pcs.
127
137
135
128
B1 B A
201
150
8269
18
CK.46.C7.02
130
59
46
105
28
CD.56.A1.02
B2
16
July 2003
20
Suction connector
mm
120
Height
4.2
Dimensions
123
1
May 2004
-30
13.2
16.8
20.7
24.9
-25
21.0
25.5
30.5
36.0
watt
-23.3
23.8
28.8
34.3
40.2
-20
29.7
35.6
42.3
49.3
-15
39.6
47.5
56.3
65.1
-10
51.0
61.3
72.9
83.8
-5
64.0
77.5
92.4
106
0
79.1
96.2
115
5
96.3
118
-23.3
29.0
35.0
41.7
49.0
-20
36.1
43.4
51.4
59.9
-15
48.2
57.8
68.5
79.2
-10
62.1
74.7
88.7
102
-5
78.0
94.4
113
129
0
96.4
117
140
5
118
144
-23.3
23.9
30.0
38.0
45.2
-20
26.4
32.9
41.8
49.7
-15
30.3
37.2
47.4
56.4
-10
34.2
41.5
52.9
63.0
-5
38.0
45.8
58.6
69.7
0
41.8
50.2
64.6
5
45.7
54.9
10
49.6
5
3.81
4.58
10
4.13
Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
-30
16.0
20.4
25.2
30.3
-25
25.5
31.0
37.1
43.8
-30
18.5
23.8
29.5
35.1
-25
22.5
28.5
35.9
42.7
10
142
-30
1.54
1.98
2.46
2.93
-25
1.88
2.37
2.99
3.56
-23.3
1.99
2.50
3.16
3.76
-20
2.20
2.75
3.48
4.15
-15
2.53
3.10
3.95
4.70
-10
2.85
3.46
4.41
5.25
-5
3.17
3.82
4.88
5.81
Solar panel
-30
0.71
0.71
0.70
0.71
-30
0.87
0.86
0.85
0.86
Main switch
+
LED -
Fan
W/W
-25
0.93
0.90
0.85
0.84
-23.3
1.00
0.96
0.90
0.89
-20
1.12
1.08
1.01
0.99
-15
1.31
1.28
1.19
1.15
-10
1.49
1.48
1.38
1.33
-5
1.69
1.69
1.58
1.52
0
1.89
1.92
1.78
5
2.11
2.15
-25
1.13
1.09
1.03
1.03
-23.3
1.21
1.17
1.10
1.08
-20
1.37
1.32
1.23
1.21
-15
1.59
1.55
1.44
1.40
-10
1.82
1.80
1.68
1.62
-5
2.05
2.06
1.92
1.85
0
2.31
2.34
2.17
5
2.57
2.62
+
+
F
D
C
R1
COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500
Fuse
0
3.48
4.19
5.38
8236-3
watt
Terminal plug
watt
Power consumption
rpm \ C
2,000
2,500
3,000
3,500
10
116
Thermostat
10
2.34
W/W
Test conditions
Condensing temperature
Ambient and suction gas temp.
Liquid temperature
Static cooling, 12V DC
1 Watt = 0.86 kcal/h
preliminary data
EN 12900/CECOMAF
55C
32C
55C
Compressor speed
Electronic Resistor
Motor Contr.circ.
unit
(R1)
speed
current
rpm
mA
0
AEO
6
00
173
2,000
5
04 EO
450
2,500
4
1N h A
0
865
3,000
3
1 wit
1696
3,500
2
In AEO (Adaptive Energy Optimizing) speed
mode the BD compressor will always adapt
its speed to the actual cooling demand.
10
2.86
ASHRAE
55C
32C
32C
Accessories
Devices
BD35K
Not
deliverable
from Danfoss
Mounting accessories
Bolt joint for one compressor
Bolt joint in quantities
Snap on in quantities
118-1917
118-1918
118-1919
Number
of
flashes
Error type
Wire dimensions
Size
Max length*
Max length*
AWG Cross 12V operation 24V operation
section
Gauge
mm2
ft.
ft.
12
12
10
8
2.5
4
6
10
8
13
19.5
32.8
2.5
4
6
10
16
26
39
65.6
5
8
12
20
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).
May 2004
CD.56.A1.02
CK.46.C7.02
July 2003
19
Data stamping
8185
Connectors
Mounting accessories
Nut M6
Washer
Grommet sleeve
Mounting accessories for BD compressors are supplied as a screw and nut assembly 118-1917. Each
assembly 118-1917 is supplied in a bag containing four screws, nuts, washers, grommet sleeves
and rubber grommets for mounting one compressor. The screw and nut assembly can be obtained
in quantities under code no 118-1918.
Compressor base
The compressor is equipped with DANCON connectors which consist of a thick-walled, copperplated steel tube with high corrosion resistance,
and a solderability equal to that of conventional
copper connectors.
DANCON connectors are equipped with an aluminium cap (Capsolut) which gives a tight sealing.
The seal cap is easily removed with an ordinary
pair of pliers or with a special tool.
3327-2
Cabinet base
20
Screw M6 x 25
Rubber grommet
Only filter driers which are declared by the manufacturer to be suitable for mobile applications must
be used in refrigeration systems with BD35F, BD50F and BD80F compressors. Filter material powder
ending up in the compressor will lead to excessive wear of the piston and transmission parts, and
metal particles deposited in the motor windings will cause the compressor to stop because the
electric signal back to the electronic unit is disturbed.
CK.46.C7.02
May 2004
CK.46.C7.02
21
Compressors
BD35F mm Standard
BD35F mm Solar
BD35F inch
Code no
101Z0200
101Z0210
101Z0204
Description
Standard compressor, mm tube connectors, UL recognized
Standard compressor, mm tube connectors
Same as 101Z0200, inch tube connectors, UL recognized
BD35K (R600a)
BD50F mm
BD50F inch
BD80F mm
101Z0211
101Z1220
101Z0203
101Z0280
Code no
Description
101N0210
101N0220
101N0900
Electronic standard
Electronic EMI
Electronic extended EMI
Electronic AEO
101N0300
Electronic solar
101N0400
Electronic BD50F high start 101N0230
Electronic BD80F
101N0280
Electronic I-pack
Electronic standard
Electronic EMI
Electronic AEO
for
for
for
for
Code no
101N0211
101N0221
101N0301
Description
for BD35F/BD50F, speed setting, battery protection, 30 pcs.
for BD35F/BD50F, radiation extra shielded, speed setting, battery protection, 30 pcs.
for BD35F/BD50F, Adaptive Energy Optimization, speed setting, battery protection, 30 pcs.
Electronic solar
101N0401
Electronic BD50F high start 101N0231
Electronic BD80F
101N0281
for BD35F/BD35K, optimized for direct solar panel operation, speed setting, 30 pcs.
for BD50F only, extra high start performance, speed setting, battery protection, 30 pcs.
for BD80F only, Adaptive Energy Optimization, speed setting, battery protection, 28 pcs.
8175
Current lead-in
Permanent magnet
22
CK.46.C7.02
Shock absorber
May 2004
May 2004
CK.46.C7.02
23
Appliance controls