Sei sulla pagina 1di 40

Plug-in relays

Zelio Relay

Catalogue
January

06

Contents

Zelio Relay - plug-in relays

Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2

RSB interface relays


b Presentation, characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 4 and 5
b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
b Dimensions, Schemes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7

RXM miniature relays


b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
b Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 9 and 10
b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 11 and 12
b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 13 and 14
b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15

RUM universal relays


b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
b Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 17 and 18
b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19 and 20
b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 21 and 22
b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
b Setting-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23

RPM power relays


b Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
b characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 25 and 26
b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 27 and 28
b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 29 and 30
b Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31

RPF power relays


b Presentation, characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 32 and 33
b References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 34
b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 35

Zelio Relay - plug-in relays


b Technical appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 36 and 37

Selection guide

Application

Zelio Relay - plug-in relays

Plug-in relays
Interface relays

Number and type of contacts / conventional thermal


current (Ith on N/O contact)

Miniature relays

1 C/O / 16 A
1 C/O / 12 A
2 C/O / 8 A

2 C/O / 12 A
3 C/O / 10 A
4 C/O / 6 A
4 C/O / 3 A (low level)

24240 V
6110 V

24240 V
12220 V

Type of pins

Flat (Faston type)

Flat (Faston type)

Operational voltage

Up to a 400 V / c 300 V

Up to 250 V

Control circuit voltage

a
c

Durability
(operating cycles)

Electrical, resistive load


Mechanical, no-load

100 000
30 000 000

100 000
10 000 000

Functions

LED
Test button and mechanical indicator
Low level contacts

Yes (with protection modules)

Yes (depending on version)


Yes
Yes

Type reference

RSB

RXM

Page

11 and 12

Conventional thermal current (Ith)

12 A (1)

10 A

12 A (2)

Contact terminal arrangements

Separate

Mixed

Separate

Connection

Connector

Screw clamp terminals


or connector

Connector

Accessories Protection modules


Timer module
Maintaining clamps
Socket identification legend
Mounting adapters for 5 rail
Mounting adapters with fixing lugs
Bus jumper, 2-pole (Ith = 5 A)

Yes

Yes
Yes

Yes

Yes
Yes (except RXZ E2M114)
Yes
Yes

Yes

Associated socket types

RSZ E1SppM

RXZ E2Mppp

Pages

RXZ E2Sppp

6
12
12
(1) When using relay RSB 1A160pp with socket RSZ E1S48M, terminals must be linked.
(2) Except for sockets RXZ E2S11pM: 10 A.

Relays with clamp fixing


Universal relays

Power relays

2 C/O / 10 A
3 C/O / 10 A
3 C/O / 3 A (low level)

2 C/O / 10 A
3 C/O / 10 A

1 C/O / 15
2 C/O / 15
3 C/O / 15
4 C/O / 15

A
A
A
A

2 N/O / 30 A (3)
2 C/O / 30 A (3)

24230 V
12220 V

12110 V

24230 V
12110 V

24240 V
12125 V

Cylindrical

Flat (Faston type)

Flat (Faston type)

Flat (Faston type)

Up to 250 V

Up to 250 V

Up to 250 V

100 000
5 000 000

100 000
10 000 000

50 000
5 000 000

Yes (depending on version)


Yes
Yes

Yes (depending on version)


Yes

RUM

RPM

RPF

19

27

34

12 A

16 A

Mixed

Connector

Connector

Yes
Yes
Yes
Yes

Yes

Yes
Yes (for 3 and 4-pole)
Yes (on socket RPZ F1)
Yes
Yes
Yes

RUZ CpM

RUZ SCpM

RPZ Fp

Mixed

Separate

RUZ SF3M

20
20
28
(3) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side without a gap.

Zelio Relay - plug-in relays

Presentation,
characteristics

523139

RSB interface relays

Presentation of the range

The RSB interface relay range comprises:


1 12 A relays with1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with
2 C/O contacts.
2 Sockets with separate contact terminals.
3 Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these
modules are common to all sockets.
4 A plastic maintaining clamp for all sockets.
5 Clip-in legends for the sockets.

4
1

Socket description

Sockets with separate contact terminals (1)


1 Connection by connector.
2 Five or eight female contacts for the relay pins.
3 A fixing hole for panel mounting.
4 Location for protection modules.
5 Locking components for plastic maintaining clamp.
6 Locating slot for mounting on 5 rail.

535188

1
Inputs

Outputs

2
5
3

(1) The inputs and outputs are separate from the relay supply.

Relay supply

General characteristics
Conforming to standards
Product certifications
Ambient air temperature
around the device

C
Storage
C
Operation
Vibration resistance
Conforming to IEC/EN 60068-2-6
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

IEC/EN 61810-1, UL 508, CSA C22-2 n 14


UL, CSA
- 40+ 85
c - 40+ 85, a - 40...+ 70
> 10 gn (10150 Hz)
IP 40
5 gn
10 gn
RT I
Any

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
a V
a V
a V

400
3.6 (1.2/50 s)
5000
2500
1000

RSB 1A160pp
1 C/O

RSB 2A080pp
2 C/O

RSB 1A120pp
1 C/O
AgNi
12

16

A
A

12
6

16
8

8
4

V
mA
VA

72 000
600
a 400, c 300
5
3000

4000

2000

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal current
(Ith)
Rated operational current
in utilisation categories
AC-1 and DC-1
Maximum operating rate
In operating cycles/hour
Switching voltage
Switching capacity

References:
page 6

For ambient
temperature y 40C
Conforming to IEC

No-load
Under load
Maximum
Minimum
Maximum

Dimensions, schemes:
page 7

N/O
N/C

Characteristics

Zelio Relay - plug-in relays

RSB interface relays

Contact characteristics (continued)


Relay type
Mechanical durability
Electrical durability
In millions of operating
cycles/hour

RSB 2A080pp

16 A - 250 V: u 0.07

8 A - 250 V: u 0.1

A
106

C
B

104

Maximum switching capacity on resistive load


c

1
0,8

Current c

Reduction coefficient (A)

107
Durability (Number of operating cycles)

RSB 1A160pp

Reduction coefficient for inductive load a


(depending on power factor cos )

Electrical durability of contacts


Resistive load a

105

RSB 1A120pp
u 30
12 A - 250 V: u 0.1
See curves below

In millions of operating cycles


Resistive load
Inductive load

0,6
0,5

0,4 0,8 1 1,2


1,6
Switching capacity (kVA)

A RSB 2A080pp

C
A

0,5

0,1
10,8 0,6

B RSB 1A160pp

16
12
8
5
2
1

0,4

0,3
0

50

0,2
cos

0,4

10

20 30

50

100

200 300

Voltage c

C RSB 1A120pp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

Coil characteristics
Average consumption
Drop-out voltage threshold
Operating time
Between coil energisation
(response time)
and making of the
On-delay contact
Between coil de-energisation
and making of the
Off-delay contact

a
c

ms
ms

c 0.45 W, a 0.75 VA
c 0.1 Uc, a 0.15 Uc
About 12
About 9

a
c

ms
ms

About 10
About 4

6
RD
90
4.8
6.6

12
JD
360
9.6
13.2

24
BD
1440
19.2
26.4

48
ED
5700
38.4
52.8

60
ND
7500
48
66

110
FD
25 200
88
121

120

220

230

240

B7
400
19.2
20.4
26.4

E7
1550
38.4
40.8
57.6

F7
10 200
96
102
144

M7
35 500
176
187
264

P7
38 500
184
195.5
276

U7
42 500
192
204
288

Control circuit voltage Uc


Relay control voltage codes
DC
Average resistance at 20 C 10%
Operating
Min.
voltage limits
Max.
Relay control voltage codes
AC
Average resistance at 20 C 15%
50/60 Hz
Operating
Min.
50 Hz
voltage limits
60 Hz
Max.

50/60 Hz

V
V

V
V

Socket characteristics
Socket type
Relay types used

RSZ E1S35M
RSB 1A120pp

Product certifications
Conventional thermal current (Ith)
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid cable without cable end
Flexible cable with cable end

A
mm2
mm2
Nm

Maximum tightening torque


Contact terminal arrangement

RSZ E1S48M
RSB 2A080pp
RSB 1A160pp (1)

UL, CSA
12
IP 20
1 conductor: 0.52.5 mm 2 (AWG 20AWG 12)
2 conductors: 0.51.5 mm 2 (AWG 20AWG 14)
1 conductor: 0.22.5 mm 2 (AWG 24AWG 14)
2 conductors: 0.21.5 mm 2 (AWG 24AWG 16)
0.6 (M3 screw)
Separate

(1) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection
schemes on page 7.

Presentation:
page 4

References:
page 6

Dimensions, schemes:
page 7

References

Zelio Relay - plug-in relays

RSB interface relays

560583

Relays for standard applications


Control circuit voltage

Number and type of contacts - Thermal current (Ith)


1 C/O -12 A
1 C/O -16 A
2 C/O -8 A
Unit
Unit
Unit
reference (1)
reference (1)
reference (1)

Weight

V
c6

10

RSB 1A120RD

RSB 1A160RD

RSB 2A080RD

kg
0.014

c 12

10

RSB 1A120JD

RSB 1A160JD

RSB 2A080JD

0.014

c 24

10

RSB 1A120BD

RSB 1A160BD

RSB 2A080BD

0.014

c 48

10

RSB 1A120ED

RSB 1A160ED

RSB 2A080ED

0.014

10

RSB 1A120ND

RSB 1A160ND

RSB 2A080ND

0.014

10

RSB 1A120FD

RSB 1A160FD

RSB 2A080FD

0.014

a 24

10

RSB 1A120B7

RSB 1A160B7

RSB 2A080B7

0.014

a 48

10

RSB 1A120E7

RSB 1A160E7

RSB 2A080E7

0.014

a 120

10

RSB 1A120F7

RSB 1A160F7

RSB 2A080F7

0.014

a 220

10

RSB 1A120M7

RSB 1A160M7

RSB 2A080M7

0.014

a 230

10

RSB 1A120P7

RSB 1A160P7

RSB 2A080P7

0.014

a 240

10

RSB 1A120U7

RSB 1A160U7

RSB 2A080U7

0.014

Connection

Relay type

Connector

RSB 1A120pp
RSB 1A160pp(2)
RSB 2A080pp

Sold in
lots of
10
10

Unit
reference
RSZ E1S35M
RSZ E1S48M

Weight
kg
0.060
0.050

For
use with

Voltage

Sold in
lots of

Unit
reference

Weight

V
c 6230

20

RZM 040W

kg
0.003

c 60
RSB 1A120JD + RZM 031FPD
+ RSZ E1S35M
c 110

560584

Sold in
lots of

Sockets - 12 A, a 300 V
Contact terminal
arrangement
RSB 1A160BD + RSZ E1S48M Separate

560582

Protection modules
Description

Diode

All sockets

RC circuit

All sockets

a 2460
a 110240

10
10

RZM 041BN7
RZM 041FU7

0.010
0.010

Diode + green LED

All sockets

c 624
c 2460
c 110230

10
10
10

RZM 031RB
RZM 031BN
RZM 031FPD

0.004
0.004
0.004

Varistor + green LED

All sockets

c or a 624
c or a 2460
c or a 110230

10
10
10

RZM 021RB
RZM 021BN
RZM 021FP

0.005
0.005
0.005

Sold in
lots of
10
10

Unit
reference
RSZ R215
RSZ L300

RSB 2A080BD + RSZ E1S48M

560585

Accessories
Description
Plastic maintaining clamp
Legend

For
use with
All sockets
All sockets

(1) To order a relay complete with socket (sold in lots of 20): add suffix S to the references selected above.
Example: RSB 2A080RD + RSZ E1S48M becomes RSB 2A080RDS.
(2) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 7.
RSZ R215

Presentation:
page 4

Characteristics :
pages 4 and 5

Dimensions, schemes:
page 7

Weight
kg
0.002
0.001

Zelio Relay - plug-in relays

Dimensions,
schemes

RSB interface relays

Dimensions
Interface relays
RSB 1A120pp

RSB 2A080pp, RSB 1A160pp

12,5
7,5

12,5
7,5

29
15

16,5

29

15,7
3,9

2,5

2,5

3,5

3,5

15,7
3,9

Sockets
RSZ E1S35M

RSZ E1S48M

67
61

67
61

(4)

(4)

11
14

12

11

24

14

22

12

A2

A1

(1)

(3)

29,4

(2)
A2

29,4

78,5

78,5

(1)

(3)

21

(2)

A1

15,5

27,5
34,5

15,5

27,5
34,5
50

50
(1) Relays
(2) Add-on protection module
(3) Maintaining clamp
(4) Legend

Schemes

24

A2
A1

22

21

14

12

11

A1

21

11

12

22

12

22

A2

11

21

A1

14

14

A1

A2

12

24

24

A2

11

A2

RSB 2A080pp

14/24

A2
A1

14

A1

RSB 1A160pp

11/21

14

12

11

RSB 1A120pp

12/22

Interface relays

When using relay RSB 1A160 pp with socket


RSZ E1S48M: terminals 11 and 21, 14 and 24,
12 and 22 must be linked

Presentation:
page 4

Characteristics:
pages 4 and 5

References:
page 6

Presentation

Zelio Relay - plug-in relays

535234

RXM miniature relays

Presentation of the range

The RXM miniature relay range comprises:


1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with
4 C/O contacts and 3 A low level relays with 4 C/O contacts. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor). All these modules are common
to all sockets.
4 A metal maintaining clamp for all sockets.
5 A plastic maintaining clamp for all sockets.
6 A 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify cabling when creating an equipotential link between the coil
terminals.
7 Clip-in legends for all the sockets except RXZ E2M114.

4
or
5
6
3

Relay description
535189

8
1
2
3
4

523151

535192

523152

7 6

10

1 Spring return pushbutton for testing the contacts (green: c, red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enabling forced maintaining of the contacts for test or
maintenance purposes. During operation, this lock-down door must always be in
the closed position.
4 LED (depending on version) indicating the relay status.
5 Removable legend for relay identification.
6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.
7 Eight, eleven or fourteen Faston type pins.
8 Area by which the product can be easily gripped.
9 Mounting adapter enabling direct mounting of the relay on a panel.
10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

Socket description

Sockets with mixed contact terminals (1)


1 Connection by screw clamp terminals or connector.
2 Fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal maintaining clamps.
5 Locating slot for mounting on 5 rail with fixing clip.
6 Two or four fixing holes for panel mounting.

535190

Outputs

2
4
3
Inputs

Relay supply

6
535191

1
Inputs

Outputs

2
4

(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the
opposite side of the socket.
(2) The inputs and outputs are separated from the relay supply terminals.

5 7

Relay supply

References:
pages 11 and 12

Sockets with separate contact terminals (2)


1 Connection by connector.
2 Eight, eleven or fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal maintaining clamps.
5 Locating slot for mounting on 5 rail with fixing clip.
6 Two fixing holes for panel mounting.
7 Location for bus jumpers (see mounting on sockets on page 14).

Dimensions:
pages 13 and 14

Schemes:
page 15

Characteristics

Zelio Relay - plug-in relays

RXM miniature relays

General characteristics
Conforming to standards
Product certifications
C
Ambient air temperature around Storage
the device
Operation
C
Vibration resistance
Conforming to IEC/EN 60068-2-6
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


UL, CSA pending
- 40 + 85
- 40 + 55
> 6 gn (10...50 Hz)
IP 40
10 gn
5 gn
RT I
Any

Insulation characteristics
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
a V
a V
a V

250 (IEC), 300 (UL, CSA)


3.6 (1.2/50 s)
2500
2500
1500

RXM 3ABppp
3 C/O

RXM 4ABppp
4 C/O

RXM 2ABppp
2 C/O
AgNi
12

10

RXM 4GBppp
4 C/O
AgAu
3

12
6
12
18 000
1200
a/c 250
10 mA on 17 V
3000
20 %
10
0.1
See curves below

10
5
10

6
3
6

2
1
3

2500

1500

2 mA on 5 V
1500

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
For ambient
current (Ith)
temperature y 55 C
Rated operational current
Conforming to IEC N/O
in utilisation categories
N/C
AC-1 and DC-1
Conforming to UL
Maximum operating rate
No-load
In operating cycles/hour
Under load
Switching voltage
Maximum
Switching capacity
Minimum
Maximum
Utilisation coefficient
Mechanical durability
In millions of operating cycles
Electrical durability
Resistive load
In millions of operating
Inductive load
cycles/hour

Reduction coefficient for inductive load a


(depending on power factor cos )

107

106

D
C

105
0

0,6
0,5

10
6
3

0,4

1
2
Switching capacity (kVA)

A RXM 2ABppp

1
0,8

Maximum switching capacity on resistive load


c
Current c

Reduction coefficient (A)

Electrical durability of contacts


Resistive load a

Durability (Number of operating cycles)

V
mA
VA

B RXM 3ABppp

0,1

0,3

10,8 0,6

C RXM 4ABppp

0,4

0,2
cos

50

100

150

200
250
Voltage c

D RXM 4GBppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

References:
pages 11 and 12

Dimensions:
pages 13 and 14

Schemes:
page 15

Characteristics
substitution

Zelio Relay - plug-in relays

(continued),
1

RXM miniature relays

Coil characteristics
Average consumption
Drop-out voltage threshold
Operating time
(response time)

Between coil energisation


and making of the
On-delay contact
Between coil de-energisation
and making of the
Off-delay contact

Control circuit voltage Uc


Relay control voltage codes
DC
Average resistance
at 20 C 10%
Operating voltage limits

Relay control voltage codes


AC
Average resistance
at 20 C 15%
Operating voltage limits

a
c
a
c
a
c

VA
W

ms
ms

1.2
0.9
u 0.15 Uc
u 0.1 Uc
20
20

a
c

ms
ms

20
20

12
JD
160

24
BD
650

48
ED
2600

110
FD
11 000

120

125
GD
11 000

220
MD
14 000

230

240

V
V

9.6
13.2

19.2
26.4

38.4
52.8

88
121

100
138

176
242

B7
180

E7
770

F7
4430

M7
15 000

P7
15 000

U7
15 500

V
V

19.2
26.4

38.4
52.8

96
132

176
242

184
253

192
264

Min.
Max.

Min.
Max.

Socket characteristics
Socket type
Relay types used

RXZ E2S108M RXZ E2S111M


RXM 2ppppp
RXM 3ppppp

Product certifications
Conventional thermal current (Ith)
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid cable without cable end
Flexible cable with cable end
Maximum tightening torque
Contact terminal arrangement
Bus jumper Ith: 5 A

RXZ E2S114M RXZ E2M114


RXZ E2M114M
RXM 4ppppp
RXM 2ppppp(1) RXM 2ppppp(1)
RXM 4ppppp
RXM 4ppppp

UL, CSA (pending)


12
10
IP 20
mm2
1 conductor: 0.52.5 mm2 (AWG 20AWG 12)
2 conductors: 0.51.5 mm2 (AWG 20AWG 14)
mm2
1 conductor: 0.22.5 mm2 (AWG 24AWG 14)
2 conductors: 0.21.5 mm2 (AWG 24AWG 16)
Nm
0.6 (M3 screw)
Separate
Mixed
Yes
No
(1) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not
exceed 10 A.
A

Substitution table
Old ranges

RXN
Miniature relays
RXN 21E1ppp

RXN 41G1ppp

RXN 41G1pppTQ
RXN 21E1pppTQ

New range

RXL

RXM

RXL 2A12Bppp
RXL 3A10Bppp
RXL 4A06Bppp
RXL 4G06Bppp
RXL 2A12BpppTQ
RXL 4A06BpppTQ

RXM 2ABppp
RXM 3ABppp
RXM 4ABppp
RXM 4GBppp
RXM 2ABpppTQ
RXM 4ABpppTQ

RXZ E1M114
RXZ 7G
RXZ E1M114M
RXZ E1p1ppM

RXZ E2M114
RXZ E2M114M
RXZ E2M114M
RXZ E2p1ppM

RXM 040MD
RZM 040W
RZM 031pp
RZM 041pp7
RZM 021pp

RXM 040W
RXM 040W
RXM 040W (2)
RXM 041pp7
RXM 021pp (2)

Sockets
RXZ E1M114
RXZ 7G
RXZ E1M114M
RXZ E1p1ppM

Protection modules
RXM 040MD
RZM 040W
RZM 031pp
RZM 041pp7
RZM 021pp

Accessories

Presentation:
page 8

10

References:
pages 11 and 12

RXZ 200
RXZ 200
RXZ R235
RXZ R235
RXZ L320
RXZ L320
(2) d Protection module without LED.
Dimensions:
Schemes:
pages 13 and 14
page 15

RXZ 400
RXZ R335
RXZ L420

References

Zelio Relay - plug-in relays

RXM miniature relays

535189

Miniature relays without LED (sold in lots of 10)


Control
circuit voltage

RXM pAB2F7

V
c 12
c 24
c 48
c 110
c 220

Number and type of contacts - Thermal current (Ith)


2 C/O -12 A
3 C/O - 10 A
Unit
Weight
Unit
Weight
reference
reference
kg
kg
RXM 2AB1JD
0.037
RXM 3AB1JD
0.038
RXM 2AB1BD
0.037
RXM 3AB1BD
0.038
RXM 2AB1ED
0.037
RXM 3AB1ED
0.038
RXM 2AB1FD
0.037
RXM 3AB1FD
0.038

RXM 4AB1JD
RXM 4AB1BD
RXM 4AB1ED
RXM 4AB1FD
RXM 4AB1MD

kg
0.036
0.036
0.036
0.036
0.036

a
a
a
a
a

RXM 2AB1B7
RXM 2AB1E7
RXM 2AB1F7
RXM 2AB1P7

24
48
120
230
240

4 C/O - 6 A
Unit
reference

Weight

0.037
0.037
0.037
0.037

RXM
RXM
RXM
RXM

3AB1B7
3AB1E7
3AB1F7
3AB1P7

0.038
0.038
0.038
0.038

RXM 4AB1B7
RXM 4AB1E7
RXM 4AB1F7
RXM 4AB1P7
RXM 4AB1U7

0.036
0.036
0.036
0.036
0.036

Miniature relays with LED (sold in lots of 10)


c 12
c 24
c 48
c 110
c 125

RXM 2AB2JD
RXM 2AB2BD
RXM 2AB2ED
RXM 2AB2FD

0.037
0.037
0.037
0.037

RXM
RXM
RXM
RXM

3AB2JD
3AB2BD
3AB2ED
3AB2FD

0.038
0.038
0.038
0.038

RXM 4AB2JD
RXM 4AB2BD
RXM 4AB2ED
RXM 4AB2FD
RXM 4AB2GD

0.036
0.036
0.036
0.036
0.036

a
a
a
a

RXM 2AB2B7
RXM 2AB2E7
RXM 2AB2F7
RXM 2AB2P7

0.037
0.037
0.037
0.037

RXM
RXM
RXM
RXM

3AB2B7
3AB2E7
3AB2F7
3AB2P7

0.038
0.038
0.038
0.038

RXM 4AB2B7
RXM 4AB2E7
RXM 4AB2F7
RXM 4AB2P7

0.036
0.036
0.036
0.036

24
48
120
230

535189

Miniature relays with low level contacts, without LED (sold in lots of 10)
Control
circuit voltage

RXM 4GB2F7

V
c 12
c 24
c 48
c 110

Number and type of contacts


Thermal current (Ith)
4 C/O - 3 A
Unit
Weight
reference
kg
RXM 4GB1JD
0.036
RXM 4GB1BD
0.036
RXM 4GB1ED
0.036
RXM 4GB1FD
0.036

a
a
a
a

RXM 4GB1B7
RXM 4GB1E7
RXM 4GB1F7
RXM 4GB1P7

0.036
0.036
0.036
0.036

c 12
c 24
c 48
c 110

RXM 4GB2JD
RXM 4GB2BD
RXM 4GB2ED
RXM 4GB2FD

0.036
0.036
0.036
0.036

a
a
a
a
a

RXM 4GB2B7
RXM 4GB2E7
RXM 4GB2F7
RXM 4GB2P7
RXM 4GB2U7

0.036
0.036
0.036
0.036
0.036

24
48
120
230

Miniature relays with low level contacts, with LED (sold in lots of 10)

Presentation:
page 8

24
48
120
230
240

Characteristics:
pages 9 and 10

Dimensions:
pages 13 and 14

Schemes:
page 15

11

References

(continued)

Zelio Relay - plug-in relays

RXM miniature relays

535235

Miniature relays without LED (sold in lots of 100)


Control
circuit voltage

RXZ E2M114M
+
Relay RXM 4AB2P7TQ

V
c 12
c 24
c 48
c 110
c 220

Number and type of contacts - Thermal current (Ith)


2 C/O - 12 A
Unit
Weight
reference
kg

RXM 2AB1BDTQ
0.037

RXM
RXM
RXM
RXM
RXM

4AB1JDTQ
4AB1BDTQ
4AB1EDTQ
4AB1FDTQ
4AB1MDTQ

kg
0.036
0.036
0.036
0.036
0.036

a
a
a
a

RXM 2AB1B7TQ

RXM 2AB1F7TQ
RXM 2AB1P7TQ

0.037

0.037
0.037

RXM
RXM
RXM
RXM

4AB1B7TQ
4AB1E7TQ
4AB1F7TQ
4AB1P7TQ

0.036
0.036
0.036
0.036

0.037
0.037

RXM 4AB2BDTQ
RXM 4AB2B7TQ
RXM 4AB2P7TQ

0.036
0.036
0.036

24
48
120
230

4 C/O - 6 A
Unit
reference

Weight

Miniature relays with LED (sold in lots of 100)

535211

c 24
a 24
a 230

RXM 2AB2B7TQ
RXM 2AB2P7TQ

Sockets
Contact terminal
arrangement
Mixed

Connection

Relay type

Sold in
lots of
10

Unit
reference
RXZ E2M114 (1)

Screw clamp terminals

RXM 2pppp(3)
RXM 4pppp
RXM 2pppp(3)
RXM 4pppp
RXM 2pppp
RXM 3pppp
RXM 4pppp

10

RXZ E2M114M (1)

0.056

10
10
10

RXZ E2S108M (2)


RXZ E2S111M (1)
RXZ E2S114M (1)

0.058
0.066
0.070

For
use with

Sold in
lots of

Unit
reference

V
c 6...250

All sockets

20

RXM 040W

kg
0.003

RC circuit

a 24...60
a 110...240

All sockets
All sockets

20
20

RXM 041BN7
RXM 041FU7

0.010
0.010

Varistor

a/c 6...24
a/c 24...60
a/c 110...240

All sockets
All sockets
All sockets

20
20
20

RXM 021RB
RXM 021BN
RXM 021FP

0.030
0.030
0.030

Connector
Separate

Connector

Weight
kg
0.048

Protection modules
RXZ E2S114M
+
Relay RXM 4AB2F7

Description

535212

Diode

RXM 041 pp7

Voltage

Weight

Timing relays
Description
535195

2 or 4 timed C/O contacts


(function A)

For
use with
Sockets RXZ Eppppp

Unit
reference
RE XL2pp (4)
RE XL4pp (4)

Weight
kg

Accessories
Description

535215

RE XL4 pp

RXZ 400

Metal maintaining clamp


Plastic maintaining clamp
Bus jumper, 2-pole
(Ith: 5 A)
Mounting adapter
for 5 rails (5)
Mounting adapter
with fixing lugs for panel
Clip-in legends

For
use with
All sockets
All sockets
All sockets with separate contacts

Sold in
lots of
10
10
10

Unit
reference
RXZ 400
RXZ R335
RXZ S2

Weight
kg
0.001
0.005
0.005

All relays

10

RXZ E2DA

0.004

All relays

10

RXZ E2FA

0.002

All relays (sheet of 108 legends)


All sockets except RXZ E2M114

10
10

RXZ L520
RXZ L420

0.080
0.001

(1) Thermal current Ith: 10 A


(2) Thermal current Ith: 12 A
(3) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A.
(4) Please consult the "Zelio Time timing relays" catalogue.
(5) Test button becomes inaccessible.

Presentation:
page 8

12

Characteristics:
pages 9 and 10

Dimensions:
pages 13 and 14

Schemes:
page 15

Dimensions

Zelio Relay - plug-in relays

RXM miniature relays

Dimensions
Miniature relays
RXM pppppp
Common view

RXM 2
Pin side view

RXM 3

21
7

40

= = =

27

6,5 6 4 4

RXM 4

21

2,5

21
2,5

2,5

2,5

13,5

4,5
2,5

13,5

2,5
13,5

Sockets
RXZ E2M114

RXZ E2M114M

43

40
19

17

25,5

(4)
24
6

44

34

44
8

14
5

42

32

22 12

32

22

12

A2
14

(3)

A1
13

41

31

21

12

11

10

39,5

11

(2)

(2)

A2

(3)

21

3,5

A1

14
41

31

21

13
11

12

11

10

50
23

80

(1)

24 14

40

42

61

79

(1)

34
7

23,5

67

27

30

30
69

Common side view

RXZ E2S108M

RXZ E2S111M

RXZ E2S114M

61
19
41
12

11
9

31

44
8

14
5

34

42
4

12
1

32

A2

A1

14

13

24
6

31

21 11

12
44

11
34

10 9
24 14

8
42

7
32

6
5
22 12

14
5

22
3

41
7

11
8

12
2

3,5

(5)
29

23
70

38

38

(2)
(3)

38

79

(1)

21
9

A2

A2

A1
14

13

A1
14

13

23,5

23,5

23,5

27

27

27

(1) Relays
(2) Add-on protection module
(3) Maintaining clamp
(4) 2 elongated holes 3.5 x 6.5
(5) 2 bus jumpers

Presentation:
page 8

Characteristics:
pages 9 and 10

References:
pages 11 and 12

Schemes:
page 15

13

Dimensions (continued)

Zelio Relay - plug-in relays

RXM miniature relays

Dimensions (continued)
Plastic clamp and clip-in legends
RXZ R335

RXZ L420

57

Mounting on all sockets (1)

14,2

(1)

94,5

27

12

26,5

81

(1) Clip-in legends for all sockets except


RXZ E2M114.

Bus jumper

Metal clamp

RXZ S2

Mounting on sockets with separate contacts


(view from below)
Example of bus jumper mounting on sockets

RXZ 400

26

7,3

2,2

25

22

(1)

(1)

(2)

(2)

2,3
37
1,2

(1) 2 bus jumpers (polarity A2)


(2) 2 bus jumpers (polarity A1)

Mounting adapter for panel

RXZ E2DA

RXZ E2FA

38

43

48

38

Mounting adapter for rail (1)

3,5
6

48

4
24

23
51

(1) Test button becomes inaccessible

Presentation:
page 8

14

Characteristics:
pages 9 and 10

References:
pages 11 and 12

3,5
49

4
24

Schemes

Zelio Relay - plug-in relays

RXM miniature relays

Schemes
Miniature relays

A2

41

A1

44

34

32

42

31

22

24
21

14

12

A2
A1

11

34
31

24

32

22

RXM 4ppppp

21

14

12

A2
A1

11

44

RXM 3ppppp

41

42

14
11

12

RXM 2ppppp

12
5

42
8

12

22

32

12
5

22
6

32
7

42
8

14
9

44
12

14
7

24
8

34
9

14
9

24
10

34
11

44
12

11
13

41
14

11
13

21

31
14

11
13

21

31

41
14

A1

A2

A1

A2

A1

A2

Symbols shown in blue correspond to Nema marking.

Presentation:
page 8

Characteristics:
pages 9 and 10

References:
pages 11 and 12

15

Presentation

Zelio Relay - plug-in relays

535216

RUM universal relays

Presentation of the range

The RUM universal relay range comprises:


1 10 A relays with 2 and 3 C/O contacts, with cylindrical or flat (Faston type) pins,
and 3 A low level relays with 3 C/O contacts, with cylindrical pins. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these
modules are common to all sockets.
4 A metal maintaining clamp for all sockets.
5 A 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify cabling when creating an equipotential link between the coil
terminals.
6 Clip-in legends for the sockets.

4
5

Relay description

535196

1 Spring return pushbutton for testing the contacts (green: c, red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enabling forced maintaining of the contacts for test or
maintenance purposes. During operation, this lock-down door must always be in
the closed position.
4 LED (depending on version) indicating the relay status.
5 Removable legend for relay identification.
6 Eight or eleven cylindrical or flat (Faston type) pins.
7 Area by which the product can be easily gripped.

1
2
3
4
6

Socket description

535218

Sockets with mixed contact terminals (1)


1 Connection by connector.
2 Eight or eleven female contacts for the relay cylindrical pins.
3 Location for protection modules or the timer module.
4 Locking component for metal maintaining clamp.
5 Locating slot for 5 rail mounting.
6 Two fixing holes for panel mounting.

Outputs

2
6
4
3
Relay supply
Inputs

Relay supply

6
Inputs

Sockets with separate contact terminals (2)


1 Connection by connector.
Inputs 2 a Eight or eleven female contacts for the relay cylindrical pins.
b Eleven female contacts for the relay flat pins.
3 Location for protection modules or the timer module.
Outputs
4 Locking component for metal maintaining clamp.
5 Locating slot for mounting on 5 rail with fixing clip.
2b
6 Two fixing holes for panel mounting.
7 Location for bus jumpers (see mounting on sockets on page 22).
4
1

535198

535197

Outputs

4
2a
3

57

Relay supply

References:
pages 19 and 20

16

57

(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the
opposite side of the socket.
(2) The inputs and outputs are separated from the relay supply terminals.

5 Relay supply

Dimensions:
pages 21 and 22

Schemes:
page 22

Characteristics

Zelio Relay - plug-in relays

RUM universal relays

General characteristics
Conforming to standards
Product certifications
Ambient air temperature
around the device

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


UL, CSA (pending)
- 40 + 85
- 40 + 55
4 gn (10...50 Hz)
IP 40
10 gn
5 gn
RT I
Any

C
Storage
Operation
C
Vibration resistance
Conforming to IEC/EN 60068-2-6
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947
Rated impulse withstand voltage (Ump)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
a V
a V
a V

250 (IEC), 300 (UL, CSA)


3.6 (1.2/50 s)
2500
2500
1500

.
A

RUM F2ppp
2 C/O
AgNi
10

A
A

10
5

2
1

10
36 000
3600
a/c 250
10 mA on 17 V
2500
20 %
5

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
For ambient
current (Ith)
temperature y 55C
Rated operational current
Conforming to IEC N/O
in utilisation categories
N/C
AC-1 and DC-1
Conforming to UL
Maximum operating rate
No-load
In operating cycles/hour
Under load
Switching voltage
Maximum
Switching capacity
Minimum
Maximum
Utilisation coefficient
Mechanical durability
In millions of operating cycles
Resistive load
Inductive load

106

RUM C3Gpp
3 C/O
AgAu
3

0.1
See curves below

Reduction coefficient (A)

Durability (Number of operating cycles)

107

RUM C3App
3 C/O

3 mA on 5 V
750

Reduction coefficient for inductive load a


(depending on power factor cos )

Electrical durability of contacts


Resistive load a

RUM C2ppp
2 C/O

1
0,8

Maximum switching capacity on resistive load


c
Current c

Electrical durability
In millions of operating
cycles/hour

V
mA
VA

RUM F3ppp
3 C/O

0,6
0,5

10
3

0,4

B
105

0,1

0,3
0

1
2
Switching capacity (kVA)

A RUM Fppppp, RUM C2ppp, RUM C3Appp

10,8 0,6

0,4

0,2
cos

50

100

150

200
250
Voltage c

B RUM C3Gppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

References:
pages 19 and 20

Dimensions:
pages 21 and 22

Schemes:
page 22

17

Characteristics

(continued)

Zelio Relay - plug-in relays

RUM universal relays

Coil characteristics
Average consumption
Drop-out voltage threshold
Operating time
(response time)

Between coil
energisation and
making of the
On-delay contact
Between coil
de-energisation
and making of the
Off-delay contact

Control circuit voltage Uc


Relay control voltage codes
DC
Average resistance
at 20 C 10%
Operating voltage
limits
Relay control voltage codes
AC
Average resistance
at 20 C 15%
Operating voltage
limits

a
c
a
c
a
c

VA
W

ms
ms

2...3
1.4
u 0.15 Uc
u 0.1 Uc
20
20

a
c

ms
ms

20
20

12
JD
120

24
BD
470

48
ED
1800

60
ND
2790

110
FD
10 000

120

125
GD
10 000

220
MD
3700

230

V
V

9.6
13.2

19.2
26.4

38.4
52.8

48
66

88
121

100
137.5

176
242

B7
72

E7
290

F7
1700

P7
7200

V
V

19.2
26.4

38.4
52.8

96
132

184
253

Min.
Max.

Min.
Max.

Socket characteristics
Socket type
Relay types used
Product certifications
Conventional thermal current (Ith)
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid cable without cable end
Flexible cable with cable end

18

mm2
mm2
Nm

Maximum tightening torque


Contact terminal arrangement
Bus jumper
Ith: 5 A

Presentation:
page 16

References:
pages 19 and 20

RUZ C2M
RUZ C3M
RUZ SC2M
RUM C2ppppp RUM C3ppppp RUM C2ppppp
UL, CSA (pending)
12
IP 20
1 conductor: 0.52.5 mm2 (AWG 20AWG 12)
2 conductors: 0.51.5 mm2 (AWG 20AWG 14)
1 conductor: 0.22.5 mm2 (AWG 24AWG 14)
2 conductors: 0.21.5 mm2 (AWG 24AWG 16)
0.6 (M3 screw)
Mixed
Separate
No
Yes

Dimensions:
pages 21 and 22

Schemes:
page 22

RUZ SC3M
RUZ SF3M
RUM C3ppppp RUM Fppppp

References

Zelio Relay - plug-in relays

RUM universal relays

References
Relays for standard applications, without LED (sold in lots of 10)
Pins

Cylindrical

Flat (Faston type)

Control
circuit voltage

V
c 12
c 24
c 48
c 60
c 110
c 125
c 220

Number and type of contacts - Thermal current (Ith)


2 C/O -10 A
3 C/O -10 A
Unit
Weight
Unit
reference
reference
kg
RUM C2AB1JD
0.084
RUM C3AB1JD
RUM C2AB1BD
0.084
RUM C3AB1BD
RUM C2AB1ED
0.084
RUM C3AB1ED

RUM C3AB1ND
RUM C2AB1FD
0.084
RUM C3AB1FD

RUM C3AB1GD

RUM C3AB1MD

a
a
a
a

24
48
120
230

RUM
RUM
RUM
RUM

C2AB1B7
C2AB1E7
C2AB1F7
C2AB1P7

0.084
0.084
0.084
0.084

RUM C3AB1B7
RUM C3AB1E7
RUM C3AB1F7
RUM C3AB1P7

0.088
0.088
0.088
0.088

c
c
c
c

12
24
48
110

RUM
RUM
RUM
RUM

F2AB1JD
F2AB1BD
F2AB1ED
F2AB1FD

0.080
0.080
0.080
0.080

RUM F3AB1JD
RUM F3AB1BD
RUM F3AB1ED
RUM F3AB1FD

0.084
0.084
0.084
0.084

a
a
a
a

24
48
120
230

RUM
RUM
RUM
RUM

F2AB1B7
F2AB1E7
F2AB1F7
F2AB1P7

0.080
0.080
0.080
0.080

RUM F3AB1B7
RUM F3AB1E7
RUM F3AB1F7
RUM F3AB1P7

0.084
0.084
0.084
0.084

0.084
0.084
0.084

0.084

RUM C3AB2JD
RUM C3AB2BD
RUM C3AB2ED
RUM C3AB2ND
RUM C3AB2FD
RUM C3AB2GD

0.088
0.088
0.088
0.088
0.088
0.088

Weight
kg
0.088
0.088
0.088
0.088
0.088
0.088
0.088

535199

Relays for standard applications, with LED (sold in lots of 10)


Cylindrical

535200

RUM ppAB2B7

Flat (Faston type)

RUM ppAB2F7

c 12
c 24
c 48
c 60
c 110
c 125

RUM
RUM
RUM

RUM

a
a
a
a

24
48
120
230

RUM
RUM
RUM
RUM

C2AB2B7
C2AB2E7
C2AB2F7
C2AB2P7

0.084
0.084
0.084
0.084

RUM C3AB2B7
RUM C3AB2E7
RUM C3AB2F7
RUM C3AB2P7

0.088
0.088
0.088
0.088

c
c
c
c

12
24
48
110

RUM
RUM
RUM
RUM

F2AB2JD
F2AB2BD
F2AB2ED
F2AB2FD

0.084
0.084
0.084
0.084

RUM F3AB2JD
RUM F3AB2BD
RUM F3AB2ED
RUM F3AB2FD

0.086
0.086
0.086
0.086

a
a
a
a

24
48
120
230

RUM
RUM
RUM
RUM

F2AB2B7
F2AB2E7
F2AB2F7
F2AB2P7

0.084
0.084
0.084
0.084

RUM F3AB2B7
RUM F3AB2E7
RUM F3AB2F7
RUM F3AB2P7

0.086
0.086
0.086
0.086

C2AB2JD
C2AB2BD
C2AB2ED
C2AB2FD

Relays with low level contacts, with LED (sold in lots of 10)
Pins

Cylindrical

Presentation:
page 16

Characteristics:
pages 17 and 18

Control
circuit voltage

V
c 24
c 48

Number and type of contacts


Thermal current (Ith)
3 C/O - 3 A
Unit
Weight
reference
kg
RUM C3GB2BD
0.086
RUM C3GB2ED
0.086

a
a
a
a

RUM C3GB2B7
RUM C3GB2E7
RUM C3GB2F7
RUM C3GB2P7

24
48
120
230

Dimensions:
pages 21 and 22

0.086
0.086
0.086
0.086

Schemes:
page 22

19

References (continued),
substitution table

Zelio Relay - plug-in relays


1

RUM universal relays

535199

References (continued)
Sockets
Contact terminal
arrangement
Mixed

Separate

Connection

Relay type

Connector

Connector

RUZ C3M + relay RUM C3ppppp

RUM C2ppppp

Sold in
lots of
10

Unit
reference
RUZ C2M

Weight
kg
0.054

RUM C3ppppp

10

RUZ C3M

0.054

RUM C2ppppp

10

RUZ SC2M

0.095

RUM C3ppppp

10

RUZ SC3M

0.100

RUM F2pppp
RUM F3pppp

10

RUZ SF3M

0.095

Voltage

Sold in
lots of

Unit
reference

Protection modules

535202

Description

RUW 241P7

For
use with

Weight

Diode

All sockets

V
c 6250

10

RUW 240BD

kg
0.004

RC circuit

All sockets

a 110240

10

RUW 241P7

0.004

Varistor

All sockets

a/c 24
a/c 240

10
10

RUW 242B7
RUW 242P7

0.004
0.004

For
use with

Voltage

Sold in
lots of

Unit
reference

10

RUW 101MW

Timer module

535219

Description

Multifunction
RUW 101MW

All sockets

V
a/c 24240

Weight
kg
0.020

Timing relays
Description
2 timed C/O contacts
(single-function or multifunction)

For
use with
On sockets RUZ CpM

Reference
RE 48A pp (1)

Weight
kg

Weight
kg
0.001

Accessories
535217

Description
Metal maintaining clamp
Bus jumper, 2-pole
(Ith : 5 A)
Clip-in legends

535203

RUZ C200

RUZ S2

For
use with
All sockets

Sold in
lots of
10

Unit
reference
RUZ C200

All sockets with separate contacts

10

RUZ S2

0.005

All relays
(sheet of 108 legends)
All sockets with separate contacts

10

RXZ L520

0.080

10

RUZ L420

0.001

(1) Please consult the "Zelio Time timing relays" catalogue.

Substitution table
Old range

New range

RUN
Universal relays

RUM

RUN 21C2ppp
RUN 31C2ppp
RUN 21A2ppp
RUN 31A2ppp
RUN 33A22pp

RUM
RUM
RUM
RUM
RUM

F2ABppp
F3ABppp
C2ABppp
C3ABppp
C3GB2pp

Sockets
RUZ pA
RUZ pD
RUZ 1C

RUZ C3M
RUZ C2M
RUZ SF3M

Protection modules
RUW 030BD
RUW 04ppp

RUW 240BD (2)


RUW 24ppp (2)

Accessories
RUZ 2p0
(2) d Protection module without DEL.
Presentation:
page 16

20

Characteristics:
pages 17 and 18

Dimensions:
pages 21 and 22

RUZ C200

Schemes:
page 22

Dimensions

Zelio Relay - plug-in relays

RUM universal relays

Dimensions
Universal relays
RUM Fpp

55

34

34

RUM Cpp

34

53

34

Sockets
Common side view

RUZ C2M

RUZ C3M

22
24

22

12 14

34

32

24

22

14

12

2x3,1

(1)

2x3,1

5
4

75

(3)

3
2

10

INPUT A1
2

INPUT A2
7
A2

A2
7

21
7

11
8

27
63

37

37

11

(2)

A2 A2

A1
1

1
INPUT A1
2

INPUT A2
10

10

31
10

21
11

30

30

38

38

11 A1
6

89
93
RUZ SC2M

RUZ SC3M

45

63
19

19
22
5
24
6

92

14
3

(3)
7

29

A1
2

24
7

14
3

32

22

12

A2
10

(4)

30

29

36

75

34
9

40

(2)
A2
7

(4)

11
1

40

(2)

21
6

7 6 5
8
4
3
9
10
2
11 1

2
8

31
11

(1)
3

92

21
8

12
4

102

75

(1)
(3)

11
1

A1
2

32
36

102

105

105

(1) Relay
(2) Protection module
(3) Maintaining clamp
(4) 2 bus jumpers

Presentation:
page 16

Characteristics:
pages 17 and 18

References:
pages 19 and 20

Schemes:
page 22

21

Dimensions (continued)
schemes

Zelio Relay - plug-in relays

RUM universal relays

Dimensions (continued)
Sockets (continued)
RUZ SF3M

63
21
9

31
8

11
7

24
6

34
5

14
4

22

32

12

92

(1)
(3)

(2)
A2
B

(4)
46

29

27

A1
A

36

104

(1) Relay
(2) Protection module
(3) Maintaining clamp
(4) 2 bus jumpers

Metal maintaining clamps and plastic legends

Bus jumper

RUZ C200

RUZ S2

Mounting

8,5

37

3,3

35,4

32
2,3

54

Mounting on sockets with separate contacts


(view from below)
Example of bus jumper mounting on sockets
(1)
(1)

108

1,2

RUZ L420

32

(2)

12

14,2

(2)

(1) 2 bus jumpers (polarity A2)


(2) 2 bus jumpers (polarity A1)

Schemes
Universal relays

RUM C2ABppp

12
4
14

RUM F2ABppp
22
5

A1

1
11

24

A2

12
4

22
6

14
7

24
9

11
A (+)

21
B( )

A1

A2

8
21

22

Characteristics:
pages 17 and 18

References:
pages 19 and 20

24
7

5
12

14 3
A1

32

9 34
2

10
1
11

24

A2

21

A1

34

22

31

14

RUM F3ABppp

21
6

22

32

12

A2
A1

11

34
31

24

32

21

14

RUM F3ABppp

RUM C3ppppp

Symbols shown in blue correspond to Nema marking.


Presentation:
page 16

22

12

A2
A1

11

24

22

RUM C3ppppp

21

14
11

12

RUM p2ABppp

11
31

A2

12
4

32
5

22
6

14
7

34
8

24
9

11
A (+)

31

21
B( )

A1

A2

Setting-up

Zelio Relay - plug-in relays

RUM universal relays

Multifunction timer module RUW 101MW


Programming

Timing range selection

Function Timing range


selection selection
0.11 s

0.110 s

0.11 min

110 min

0.11 h

0.11 day

110 h

110 days

Function selection
Function

Control

On-delay timer
E

Series control

Function diagram

Control scheme
U

U
.1/.4
.1/.2

A1

Selection

Series control

.1/.4
.1/.2

A2

Monostable with
maintained control
Wu

Flashing relay,
starting On-delay phase
Bi

Series control

U
.1/.4
.1/.2
t t

Flashing relay,
starting Off-delay phase
Bp

Series control

U
.1/.4
.1/.2
t t

Off-delay timer
R

Control by external contact


(S)

A1

.1/.4
.1/.2

Monostable
with pulse control
Ws

Control by external contact


(S)

B1

A2

.1/.4
.1/.2

Monostable, starting
on de-energisation
Wa

Control by external contact


(S)

U
S
.1/.4
.1/.2

On-delay timer
Es

Control by external contact


(S)

U
S
.1/.4
.1/.2

Power off

Contact open

U: voltage

S: external control

Power on

Contact closed

R: relay RUM ppp

t: adjustable time delay

References:
pages 19 and 20

Dimensions:
pages 21 and 22

Presentation:
page 16

Characteristics:
pages 17 and 18

23

Presentation

Zelio Relay - plug-in relays

RPM power relays

523144

Presentation of the range


The RPM power relay range comprises:
1 15 A relays with 1, 2, 3 and 4 C/O contacts.
2 Sockets with mixed contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these
modules are common to all the sockets except for the timer module, which can
only be used on the 3-pole or 4-pole sockets.

A metal maintaining clamp for 1 contact relays.

Relay description
1 Spring return pushbutton for testing the contacts (green: c, red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enabling forced maintaining of the contacts for test or
maintenance purposes. During operation, this lock-down door must always be in
the closed position.
4 LED (depending on version) indicating the relay status.
5 Removable legend for relay identification.
6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.
7 Five, eight, eleven or fourteen Faston type pins.
8 Area by which the product can be easily gripped.
9 Mounting adapter enabling direct mounting of the relay on a panel.
10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

523145

2
3
4

523157

523156

523158

7 6

10

Socket description

523146

5
1
Outputs

Sockets with mixed contact terminals (1)


1 Connection by screw clamp terminals.
2 Five, eight, eleven or fourteen female contacts for the relay pins.
3 Location for protection modules or the timer module.
4 Locating slot for mounting on 5 rail with fixing clip.
5 Two or four fixing holes for panel mounting.
(1) The inputs are mixed with the relays supply terminals, with the outputs being located on the
opposite side of the socket.

Supply
relay

References:
pages 27 and 28

24

Inputs

Dimensions:
pages 29 and 30

Schemes:
page 31

Characteristics

Zelio Relay - plug-in relays

RPM power relays

General characteristics
Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation

Vibration resistance
Degree of protection
Shock resistance
conforming to IEC/EN 60068-2-27

Conforming to IEC/EN 60068-2-6


Conforming to IEC/EN 60529
Opening
Closing

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


UL, CSA (pending)
- 40 + 85
- 40 + 55

C
C

6 gn (10...50 Hz)
IP 40
10 gn
10 gn
RT I
Any

Protection category
Mounting position

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
aV
aV
aV

250 (IEC), 300 (UL, CSA)


3.6 (1.2/50 s)
2500
2500
1500

RPM 1ppp
1 C/O
AgNi
15

Contact characteristics

107

106

105
0

4
3,75
Switching capacity (kVA)

RPM 3ppp
3 C/O

RPM 4ppp
4 C/O

15
7.5
15
18 000
1200
a/c 250
100 mA on c 5 V
3750
20 %
10

V
mA
VA

0.1
See curves below

0.06

Reduction coefficient for inductive load a


(depending on power factor cos )
Reduction coefficient (A)

Durability (Number of operating cycles)

Electrical durability of contacts


Resistive load a

A
A
A

RPM 2ppp
2 C/O

1
0,8

Maximum switching capacity on resistive load


c
Current c

Relay type
Number and type of contacts
Contact materials
Conventional thermal current For ambient
(Ith)
temperature y 55 C
Conforming to IEC N/O
Rated operational current
in utilisation categories
N/C
AC-1 and DC-1
Conforming to UL
Maximum operating rate
No-load
In operating cycles/hour
Under load
Switching voltage
Maximum
Switching capacity
Minimum
Maximum
Utilisation coefficient
Mechanical durability
In millions of
operating cycles
Resistive load
Electrical durability
In millions of operating
Inductive load
cycles/hour

0,6
0,5

0,4

15
10

0,1

0,3
10,8 0,6

0,4

0,2
cos

50

100

150

200
250
Voltage c

Durability (inductive load) = durability (resistive load) x reduction coefficient.

References:
pages 27 and 28

Dimensions:
pages 29 and 30

Schemes:
page 31

25

Characteristics

(continued)

Zelio Relay - plug-in relays

RPM power relays

Coil characteristics
Relay type
Average consumption
Drop-out voltage threshold
Operating time
(response time)

Between coil
energisation and
making of the
On-delay contact
Between coil
de-energisation
and making of the
Off-delay contact

Control circuit voltage Uc


Relay control voltage codes
DC
Average resistance
at 20 C 10%

Operating voltage
limits
Relay control voltage codes
AC
Average resistance
at 20 C 15%

Operating voltage
limits

RPM 2ppp
1.2
0.9

RPM 3ppp
1.5
1.7

RPM 4ppp
1.5
2

ms

RPM 1ppp
0.9
0.7
u 0.15 Uc
u 0.1 Uc
20

25

25

20

ms

20

25

25

20

ms

20

ms

20

24
BD
750
650
400
388
19.2
26.4

48
ED
2600
2600
2600
1550
38.4
52.8

110
FD
13 100
11 000
8600
7340
88
121

120

230

B7
160
180
103
84.3
19.2
26.4

E7
720
770
770
338
38.4
52.8

F7
4430
4430
2770
2220
96
132

P7
15 720
15 000
12 000
9120
184
253

a
c
a
c
a

VA
W

RPM
RPM
RPM
RPM
Min.
Max.

1ppp
2ppp
3ppp
4ppp

V
V

12
JD
180
160
100
96
9.6
13.2

RPM
RPM
RPM
RPM
Min.
Max.

1ppp
2ppp
3ppp
4ppp

V
V

Socket characteristics
Socket type
Relay types used
Protection module types used
Product certifications
Conventional thermal current (Ith)
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid cable without cable end
Flexible cable with cable end

26

mm2
mm2
Nm

Maximum tightening torque


Contact terminal arrangement

Presentation:
page 24

References:
pages 27 and 28

RPZ F1
RPZ F2
RPZ F3
RPM 1ppp
RPM 2ppp
RPM 3ppp
RXM 02ppp
RXM 02ppp
RUW 24ppp
RXM 04ppp
RXM 04ppp
UL, CSA (pending)
16
IP 20
1 conductor: 0.52.5 mm2 (AWG 20AWG 12)
2 conductors: 0.51.5 mm2 (AWG 20AWG 14)
1 conductor: 0.22.5 mm2 (AWG 24AWG 14)
2 conductors: 0.21.5 mm2 (AWG 24AWG 16)
0.8 (M3.5 screw)
Mixed

Dimensions:
pages 29 and 30

Schemes:
page 31

RPZ F4
RPM 4ppp
RUW 24ppp

References

Zelio Relay - plug-in relays

RPM power relays

Power relays without LED (sold in lots of 10)


Control circuit voltage

V
c 12

Number and type of contacts - Thermal current (Ith)


1 C/O - 15 A
2 C/O - 15 A
3 C/O - 15 A
Unit
Weight
Unit
Weight
Unit
Weight
reference
reference
reference
kg
kg
kg
RPM 11JD
0.024
RPM 21JD
0.036
RPM 31JD
0.054

4 C/O - 15 A
Unit
Weigh
reference
t
kg
0.068
RPM 41JD

c 24

RPM 11BD

0.024

RPM 21BD

0.036

RPM 31BD

0.054

RPM 41BD

0.068

c 48

RPM 11ED

0.024

RPM 21ED

0.036

RPM 31ED

0.054

RPM 41ED

0.068

c 110

RPM 11FD

0.024

RPM 21FD

0.036

RPM 31FD

0.054

RPM 41FD

0.068

a 24

RPM 11B7

0.024

RPM 21B7

0.036

RPM 31B7

0.054

RPM 41B7

0.068

a 48

RPM 11E7

0.024

RPM 21E7

0.036

RPM 31E7

0.054

RPM 41E7

0.068

a 120

RPM 11F7

0.024

RPM 21F7

0.036

RPM 31F7

0.054

RPM 41F7

0.068

a 230

RPM 11P7

0.024

RPM 21P7

0.036

RPM 31P7

0.054

RPM 41P7

0.068

535205

Power relays with LED (sold in lots of 10)


c 12

RPM 12JD

0.024

RPM 22JD

0.036

RPM 32JD

0.054

RPM 42JD

0.068

c 24

RPM 12BD

0.024

RPM 22BD

0.036

RPM 32BD

0.054

RPM 42BD

0.068

c 48

RPM 12ED

0.024

RPM 22ED

0.036

RPM 32ED

0.054

RPM 42ED

0.068

c 110

RPM 12FD

0.024

RPM 22FD

0.036

RPM 32FD

0.054

RPM 42FD

0.068

a 24

RPM 12B7

0.024

RPM 22B7

0.036

RPM 32B7

0.054

RPM 42B7

0.068

a 48

RPM 12E7

0.024

RPM 22E7

0.036

RPM 32E7

0.054

RPM 42E7

0.068

a 120

RPM 12F7

0.024

RPM 22F7

0.036

RPM 32F7

0.054

RPM 42F7

0.068

RPM 22F7

a 230

RPM 12P7

0.024

RPM 22P7

0.036

RPM 32P7

0.054

RPM 42P7

0.068

Presentation:
page 24

Characteristics:
pages 25 and 26

Dimensions:
pages 29 and 30

535205

RPM 32F7

Schemes:
page 31

27

References

(continued)

Zelio Relay - plug-in relays

RPM power relays

535206

Sockets
Contact terminal
arrangement
Mixed

Connection

Relay type

Sold in
lots of
10
10
10
10

Unit
reference
RPZ F1
RPZ F2
RPZ F3
RPZ F4

Weight
kg
0.042
0.054
0.072
0.094

Screw clamp
terminals

RPM
RPM
RPM
RPM

Voltage

Socket
type

Sold in
lots of

Unit
reference

Weight

RPZ F1
RPZ F2
RPZ F3
RPZ F4
RPZ F1
RPZ F2
RPZ F1
RPZ F2
RPZ F3
RPZ F4
RPZ F1
RPZ F2
RPZ F1
RPZ F2
RPZ F1
RPZ F2
RPZ F3
RPZ F4
RPZ F3
RPZ F4

20

RXM 040W

kg
0.003

20

RUW 240BD

0.004

20

RXM 041BN7

0.010

20

RXM 041FU7

0.010

20

RUW 241P7

0.004

20

RXM 021RB

0.030

20

RXM 021BN

0.030

20

RXM 021FP

0.030

20

RUW 242B7

0.004

20

RUW 242P7

0.004

Socket
type

Sold in
lots of

Unit
reference

RPZ F3
RPZ F4

10

RUW 101MW

For
use with
RPZ F1

Sold in
lots of
20

Unit
reference
RPZ R235

Weight
kg
0.001

RPM
RPM
RPM
RPM

1ppp
2ppp
3ppp
4ppp

20
20
20
20

RPZ 1DA
RXZ E2DA
RPZ 3DA
RPZ 4DA

0.004
0.004
0.004
0.006

Mounting adapters with fixing lugs for panel

RPM
RPM
RPM
RPM

1ppp
2ppp
3ppp
4ppp

20
20
20
20

RPZ 1FA
RXZ E2FA
RPZ 3FA
RPZ 4FA

0.002
0.002
0.003
0.004

Clip-in legends
(sheet of 108 legends)

All relays

10

RXZ L520

0.080

1ppp
2ppp
3ppp
4ppp

Protection modules
Description

Diode

V
c 6...250

RPZ F2 + relay RPM 22F7

535207

RC circuit

a 24...60
a 110...240

RXM p41 ppp


Varistor

a/c 6..0.24
a/c 24...60
a/c 110...240
a/c 24
a/c 240

Timer module (1)


Description

V
a/c 24240

535208

Multifunction

Voltage

Weight
kg
0.020

Accessories
Description
Metal maintaining clamp
(for single-pole relays)
Mounting adapters for 5 rail (2)

535209

RPZ 1DA

RPZ 3FA

(1) See timer module description (selection of functions and time delays) on page 23
(2) Test button becomes inaccessible

Presentation:
page 24

Characteristics:
pages 25 and 26

28

Dimensions:
pages 29 and 30

Schemes:
page 31

Dimensions

Zelio Relay - plug-in relays

RPM power relays

Dimensions
Power relays
RPM 1

27

6,5 6 5

3,5

4,5

2,5

2,5

14

Common side view

RPM 2

RPM 3

RPM 4

4,5 4,5 4,5

39

4,5

4,5 4,5 4,5 4,5

27

27

6,5 6 5 4

4,5 4,5

21

31

10

27

41

10

10

40

10

10

10

15

Sockets
RPZ F2

12

42
4

12
1

13

A1
13

11

41

11

12

A2
14

17

21

71

19

30

80

26

76
RPZ F3

RPZ F4

4,5 x 6

22

42
2

10

21

34
7
32
3

22

A2

12
1

A1
13

41

11
12

11

31

21

10

28

36

37

46

40

50

References:
pages 27 and 28

14
5

14

24
6

42
4

68
A1
13
41
12

Characteristics:
pages 25 and 26

40

A2
14

76

44
8

12

68

80

30

14
5

40

24
6

44
8

4,5 x 6

40

19

30

40

Common side view

Presentation:
page 24

68

80
A1

40

80

4
A2
14

14

40

44

40

14

31

4,5 x 6

19

19

40

RPZ F1

11
9

Schemes:
page 31

29

Dimensions (continued)

Zelio Relay - plug-in relays

RPM power relays

Dimensions (continued)
Mounting adapters for 5 rail

2,5

24

50

50
23

20

34

44

2,5

RPZ 4DA

2,5

49,5

23
23

RPZ 3DA

38

RXZ E2DA

48

RPZ 1DA

24

Mounting adapters with fixing lugs for panel

3,5
16

3,5

19

24

3,5
19

16

34

Mounting
Mounting adapters for 5 rail (1)

Mounting adapters with fixing lugs for panel

(1) Test button becomes inaccessible

Presentation:
page 24

30

Characteristics:
pages 25 and 26

References:
pages 27 and 28

Schemes:
page 31

3,5

38

43

38

38

5
16,5

RPZ 4FA

43

RPZ 3FA

43

38

RXZ E2FA

43

RPZ 1FA

4
44

Schemes

Zelio Relay - plug-in relays

RPM power relays

Schemes
Power relays

14

24

13 (+)

14 ( )
A2

A1

21
8 ( )
A2

A2
A1

44
41

42

31

34

32

24
21

22

14

12

A2
A1

11

44
41

RPM 4ppp
42

24

RPM 3ppp

21

A2

5
14

A1

22

A1

2
22

11
7 (+)

14

24

1
12

11

21

14

1
12

11

12

22

12

A2
A1

RPM 2ppp

11

14

12

11

RPM 1ppp

12

22

42

12

22

32

42

14

24

44

14

24

34

44

9
11
13 (+)
A1

10

12

21

41
14 ( )

11
13 (+)

A2

A1

10

11

12

21

31

41
14 ( )
A2

Symbols shown in blue correspond to Nema marking.

Presentation:
page 24

Characteristics:
pages 25 and 26

References:
pages 27 and 28

Dimensions:
pages 29 and 30

31

Zelio Relay - plug-in relays

Presentation,
characteristics

RPF power relays


With clamp fixing

Presentation of the range


535210

RPF power relays with 2 C/O or 2 N/O contacts comprise:


4

1
2
3
4

Four or six Faston type pins.


Two relay supply pins.
A locating slot for mounting on 5 rail.
Two fixing holes for panel mounting.

General characteristics
Conforming to standards

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n14

Product certifications

UL, CSA (pending)

Ambient air temperature


around the device

Storage
Operation

Vibration resistance

Conforming to IEC 60068-2-6

>10 gn (10...55 Hz)

Degree of protection

Conforming to IEC/EN 60529

IP 40

C
C

- 40...+ 85
- 40...+ 55

Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing

10 gn
10 gn

Protection category

RT IV

Mounting position

Any

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947
Rated impulse withstand voltage (Uimp)

V
kV

250
3.6 (1.2/50 s)

Dielectric strength
(rms voltage)

Between coil and contact


Between poles
Between contacts

aV
aV
aV

2500
2500
1500

References:
page 34

Dimensions, schemes:
page 35

32

Characteristics (continued)

Zelio Relay - plug-in relays

RPF power relays


With clamp fixing

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
current (Ith)
Rated operational current
in utilisation categories
AC-1 and DC-1

RPF 2App
2 N/O
AgSnO2
For ambient
temperature y 40C
Conforming to IEC

A
N/O
N/C

Conforming to UL
No-load
Under load
Maximum
Minimum
Maximum

Maximum operating rate


In operating cycles/hour
Switching voltage
Switching capacity
Utilisation coefficient
Mechanical durability

0.05 (N/O contact only)


See curves below
Reduction coefficient for inductive load a
(depending on power factor cos )

106

105

104
1

Maximum switching capacity on resistive load


c

1
0,8

Current c

Reduction coefficient (A)

Durability (Number of operating cycles)

A
A
A

In millions of operating cycles

107

30 (when mounted with 13 mm gap between two relays)


25 (when mounted side by side without a gap)
30
3
30
18 000
1200
a/c 250
10 mA on c 17 V
7200
10 %
5

V
mA
VA

Resistive load
Electrical durability
In millions of operating
Inductive load
cycles/hour
Electrical durability of contacts
Resistive load a

RPF 2Bpp
2 C/O

0,6
0,5

10

0,4

0,1

0,3

A
B

10,8 0,6

0,2
cos

0,4

Switching capacity (kVA)

Durability (inductive load) = durability (resistive load) x reduction coefficient.

28 50

100

150

200
250
Voltage c

A RPF 2ppp: 30 A
B RPF 2ppp: 25 A

Coil characteristics
Average consumption

a
c

Drop-out voltage threshold

a
c

Operating time
(response time)

4
1.7
u 0.15 Uc
u 0.1 Uc

Between coil
energisation and
making of the
On-delay contact

ms

20

ms

20

Between coil
de-energisation
and making of the
Off-delay contact

ms

20

ms

20

12
JD
86

24
BD
350

110
FD
7255

120

230

V
V

9.6
13.2

19.2
26.4

88
121

B7
250

F7
1600

P7
6500

V
V

19.2
26.4

96
132

184
253

Control circuit voltage Uc


Relay control voltage codes
DC
Average resistance
at 20 C 10%
Operating voltage
limits
Relay control voltage codes
AC
Average resistance
at 20 C 15%
Operating voltage
limits

References:
page 34

VA
W

Min.
Max.

Min.
Max.

Dimensions, schemes:
page 35

33

References

Zelio Relay - plug-in relays

RPF power relays


With clamp fixing

535210

Power relays (sold in lots of 10)


Control
circuit voltage

RPF 2Bpp

V
c 12

Number and type of contacts - Thermal current (Ith)


2 N/O - 30 A (1)
2 C/O - 30 A (1)
Unit
Unit
Weight
reference
reference
kg
0.086
RPF 2AJD
RPF 2BJD

c 24

RPF 2ABD

RPF 2BBD

0.086

c 110

RPF 2AFD

RPF 2BFD

0.086

a 24

RPF 2AB7

RPF 2BB7

0.086

a 120

RPF 2AF7

RPF 2BF7

0.086

a 230

RPF 2AP7

RPF 2BP7

0.086

(1) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side
without a gap.

Characteristics:
pages 32 and 33

34

Dimensions, schemes:
page 35

Zelio Relay - plug-in relays

Dimensions,
schemes

RPF power relays


With clamp fixing

Dimensions
Power relays
RPF 2App, RPF 2Bpp

30

26
2 x 4,5

4,5

69

42

60

15

16

12
=

42

34

Schemes
Power relays
RPF 2App

RPF 2Bpp

14

24

14

24

11

21

11

21

12

22

A1

A2

A1

A2

Symbols shown in blue correspond to Nema marking.

Characteristics:
pages 32 and 33

References:
page 34

35

Technical appendices

Zelio Relay - plug-in relays

Relays
Contact types
Symbol

Configuration
Make contact
(Normally Open)

EU
NO

USA
SPST-NO
DPST-NO
nPST-NO (1)

Break contact
(Normally Closed)

NC

SPST-NC
DPST-NC
nPST-NC (1)

Changeover Contact CO

SPDT
DPDT
nPDT (1)

Utilisation categories
Category
AC-1

Type of current
a single-phase
a 3-phase

Applications
Resistive or slightly inductive loads.

AC-3

a 3-phase

Starting and braking of squirrel cage motors; reversing


direction of rotation only after stopping of motor.

AC-4

a 3-phase

Starting of squirrel cage motors, inching. Plugging,


reversing direction of rotation.

DC-1

Resistive or slightly inductive loads (2).

AC-14

a single-phase

Control of electromagnetic loads (< 72 VA), auxiliary


control relays, power contactors, electromagnetic
solenoid valves and electromagnets.

AC-15

a single-phase

Control of electromagnetic loads (> 72 VA), auxiliary


control relays, power contactors, electromagnetic
solenoid valves and electromagnets.

DC-13

Control of electromagnetic loads, auxiliary control relays,


power contactors, magnetic solenoid valves and
electromagnets.

Protection categories
Category
RT 0

Explanation
Condition
Unenclosed relay Relay not provided with a protective case.

RT I

Dust protected
relay

Relay provided with a case which protects its mechanism


from dust.

RT II

Flux-proof relay

RT III

Wash-tight relay

Relay capable of being automatically soldered without


allowing the migration of solder fluxes beyond the
intended areas.
Relay capable of being automatically soldered and then
washed to remove flux residues without risk of ingress of
flux or washing solvents.

RT IV

Sealed relay

RT V

Relay provided with a case which has no venting to the


outside atmosphere.

Hermetically
Sealed relay having an enhanced level of sealing.
sealed relay
(1) n = number of contacts.
(2) The switchable voltage can be doubled, for an equal current, by connecting two contacts in
series.

36

Zelio Relay - plug-in relays

Technical appendices
(continued)

Protection modules
Whenever an inductive load is de-energised (coil of a relay or of a contactor), an
overvoltage appears at its terminals. This voltage peak can reach several thousand
volts and a frequency of several MHz.
It is likely to disturb the operation of automation systems which contain electronic
devices.
Protection modules are used to reduce the voltage peak on de-energisation and
they therefore limit the energy of interference signals to a level that will not disturb
surrounding coils and electronic devices.
These modules are used to avoid:
v electromagnetic compatibility problems,
v the deterioration of contact materials,
v the destruction of insulation due to overvoltage,
v the destruction of electronic components.
Diode protection module (with or without LED)
b Advantages
v accumulation of energy allowing current flow in the same direction,
v absence of any voltage peaks at the coil terminals,
v low cost.

Break

U
Supply voltage

Energy released

b
v
v
v

Coil voltage with diode protection module (c only)

Protection module with varistor


b Advantages
v can be used with a and c supply,
v voltage peak limited to about 2 Un,
v little effect on relay drop-out time.

Break

Disadvantages
increase in relay drop-out time (3 to 4 times the usual time),
no polarity protection,
de-energisation of the relay.

b Disadvantages
v no modification of coil's own oscillating frequency,
v limitation of switching frequency.

Energy
released

Limitation of voltage
peaks

Coil voltage with varistor protection module (a and c)

Protection module with RC circuit


b Advantages
v coil oscillating frequency reduced to about 150 Hz,
v voltage peak limited to 3 Un,
v little effect on relay drop-out time.

Break

U2

U1

S2 (with RC)

b Disadvantages
v no protection for low voltages.

S1

Coil voltage with RC circuit protection module (a only)


S1 = S2 = Energy released

37

The efficiency of Telemecanique


branded solutions
Used in combination, Telemecanique products provide quality solutions,
meeting all your Automation and Control applications requirements.

A worldwide presence
Constantly available
b More than 5 000 points of sale in 130 countries.
b You can be sure to find the range of products that are right for you and which
complies fully with the standards in the country where they are used.

Schneider Electric Industries SAS


Head Office
89, bd Franklin Roosevelt
92506 Rueil-Malmaison Cedex
France
www.schneider-electric.com
www.telemecanique.com

ART. 815041

Simply Smart !
Due to evolution of standards and equipment, the characteristics indicated in texts and images of this
document do not constitute a commitment on our part without confirmation.
Design: Schneider Electric
Photos: Schneider Electric
Printed by:

01 / 2006

DIA3ED2051206EN

Technical assistance wherever you are


b Our technicians are at your disposal to assist you in finding the optimum
solution for your particular needs.
b Schneider Electric provides you with all necessary technical assistance,
throughout the world.

Potrebbero piacerti anche