Sei sulla pagina 1di 69

Set Advanced Channel Management

Parameters of Cell(SET GCELLCHMGAD)


Function
Use this command to set the advanced channel management parameters of a cell.
Note
None
Parameter
Parameter ID

Parameter
Name

IDTYPE

Index Type

Parameter Description

Meaning: Type of an index

GUI Value Range:


BYNAME(By Name),
BYID(By Index)

Actual Value Range:


BYNAME, BYID

Unit: None

Default Value: None

Recommended Value: None

Parameter ID

Parameter
Name

CELLID

Cell Index

Parameter Description

Meaning: Index of a cell,


uniquely identifying a cell in a
BSC

GUI Value Range: 0~2047

Actual Value Range: 0~2047

Unit: None

Default Value: None

Recommended Value: None


CELLNAME

Cell Name
Meaning: Name of a cell,
uniquely identifying a cell in a
BSC

GUI Value Range: None

Actual Value Range: 1~64


characters

Parameter ID

Parameter
Name

Parameter Description

Unit: None

Default Value: None

Recommended Value: None


TCHBUSYTHRES

TCH Traffic
Busy Threshold Meaning: If the current channel
seizure ratio reaches or exceeds
this value, the half-rate TCH is
assigned preferentially;
otherwise, the full-rate TCH is
assigned preferentially.

GUI Value Range: 0~100

Actual Value Range: 0~100

Unit: per cent

Default Value: None

Recommended Value: 60
INTERFPRIALLOW

Interf. Priority
Allowed

Meaning: Whether to consider

Parameter ID

Parameter
Name

Parameter Description

interference priorities during


channel assignment

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: YES


CHANINTERMESALLOW

Active CH
Interf.
Meas.Allowed

Meaning: Whether to measure


the channel interference during
channel assignment. If this
parameter is set to NO, the BSC
does not measure the channel
interference or send an
interference indication during
channel assignment. If this
parameter is set to YES, the
BSC measures the channel
interference during channel
assignment.

GUI Value Range: NO(No),

Parameter ID

Parameter
Name

Parameter Description

YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: YES


TRXPRIALLOW

Allocation
TRX Priority
Allowed

Meaning: This parameter


specifies whether the TRX
priority is considered during
channel assignment. When the
parameter is set to YES, the
smaller the parameter TRX
Priority in the command SET
GTRXDEV is, the higher
priority the TRX is. Under
other conditions, channels are
preferentially allocated from
high-priority TRXs.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Parameter ID

Parameter
Name

Parameter Description

Unit: None

Default Value: None

Recommended Value: YES


HISPRIOALLOW

History Record
Priority
Meaning: Whether to consider
Allowed
history priority records during
channel assignment.
If this parameter is set to YES,
the history priority records are
considered. If this parameter is
set to NO, the history priority
records are not considered.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: YES


LOADSHAREALLOW

Balance Traffic
Allowed
Meaning: If this parameter is
set to YES, the channel
assignment algorithm II
randomly selects the start range
for channel traversal; otherwise,
the algorithm selects the
channel next to the channel
assigned last time as the start
point of channel traversal.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: YES


UPINTERLEVLIMIT

Interf.of UL
Level
Threshold

Meaning: One of the thresholds


to determine whether the uplink
interference exists. If the uplink
level is not smaller than
Interf.of UL Level Threshold

Parameter ID

Parameter
Name

Parameter Description

and the uplink quality of the


channel is not less than
Interf.of UL Qual. Threshold,
the uplink interference exists.

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Recommended Value: 30
UPINTERFQUALLIMIT

Interf.of UL
Qual.
Threshold

Meaning: One of the thresholds


to determine whether the uplink
interference exists. If the uplink
level is not smaller than
Interf.of UL Level Threshold
and the uplink quality of the
channel is not less than
Interf.of UL Qual. Threshold,
the uplink interference exists.

GUI Value Range: 0~70

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 0~70

Unit: None

Default Value: None

Recommended Value: 40
DLINTERFLEVLIMIT

Interf.of DL
Level
Threshold

Meaning: Threshold for


determining whether downlink
interference exists. If the
downlink level is equal to or
greater than Interf.of DL Level
Threshold and the downlink
quality level is equal to or
greater than Interf.of DL
Qual.Threshold, downlink
interference exists. The value
range 0 to 63 is mapped to the
range -110 dBm to -47 dBm.

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 35
DLINTERFQUALLIMIT

Interf.of DL
Qual.Threshold Meaning: Threshold for
determining whether downlink
interference exists. If the
downlink level is equal to or
greater than Interf.of DL Level
Threshold and the downlink
quality level is equal to or
greater than Interf.of DL
Qual.Threshold, downlink
interference exists.

GUI Value Range: 0~70

Actual Value Range: 0~70

Unit: None

Default Value: None

Recommended Value: 40
SSLENSD

Filter Length
for TCH Level

Meaning: When the network

Parameter ID

Parameter
Name

Parameter Description

receives measurement reports,


the measurement values in
several straight measurement
reports are filtered to reflect the
radio operating environment for
the sake of accuracy. This
parameter specifies the number
of successive measurement
reports that are used to
determine the signal strength on
traffic/data channels.

GUI Value Range: 1~32

Actual Value Range:


TCH:480~15360, step:480;
SDCCH:470~15040, step:470

Unit: ms

Default Value: None

Recommended Value: 6
QLENSD

Filter Length
for TCH Qual.

Meaning: For the purpose of


accurately reflecting the radio
environment of a network,
filtering is performed on the
measured values in several
consecutive measurement

Parameter ID

Parameter
Name

Parameter Description

reports. This parameter


indicates the number of
measurement reports used for
the filtering of the signal quality
on service or data channels.
This parameter is used to
determine whether interferences
exist on channels.

GUI Value Range: 1~32

Actual Value Range:


TCH:480~15360, step:480;
SDCCH:470~15040, step:470

Unit: ms

Default Value: None

Recommended Value: 6
SSLENSI

Filter Length
for SDCCH
Level

Meaning: When the network


receives measurement reports,
the measurement values in
several straight measurement
reports are filtered to reflect the
radio operating environment for
the sake of accuracy. The
parameter specifies the number
of successive measurement

Parameter ID

Parameter
Name

Parameter Description

reports that are used to


determine the signal strength on
signaling channel.

GUI Value Range: 1~32

Actual Value Range:


TCH:480~15360, step:480;
SDCCH:470~15040, step:470

Unit: ms

Default Value: None

Recommended Value: 2
QLENSI

Filter Length
for SDCCH
Qual.

Meaning: For the purpose of


accurately reflecting the radio
environment of a network,
filtering is performed on the
measured values in several
consecutive measurement
reports. This parameter
indicates the number of
measurement reports used for
the filtering of the signal quality
on signaling channels. This
parameter is used to determine
whether interferences exist on

Parameter ID

Parameter
Name

Parameter Description

channels.

GUI Value Range: 1~32

Actual Value Range:


TCH:480~15360, step:480;
SDCCH:470~15040, step:470

Unit: ms

Default Value: None

Recommended Value: 2
AMRTCHHPRIORALLOW

AMR TCH/H
Prior Allowed

Meaning: Whether to enable the


BSC to assign AMR half rate
channels preferentially
according to the channel types
allowed by the MSC and the
current TCH seizure ratio of the
cell

GUI Value Range: OFF(Off),


ON(On)

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: OFF, ON

Unit: None

Default Value: None

Recommended Value: ON
AMRTCHHPRIORLOAD

AMR TCH/H
Prior Cell Load Meaning: Load threshold for
Threshold
assigning half rate channels
preferentially. If the current
TCH seizure ratio of the cell is
greater than this threshold,
AMR half rate channels are
assigned preferentially.

GUI Value Range: 0~99

Actual Value Range: 0~99

Unit: per cent

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: 55
TCHTRICBUSYOVERLAYTHR

Tch Traffic
Busy Overlay
Threshold

Meaning: The BSC assigns


channels in the overlaid subcell
to the MS in a concentric cell.
If the channel seizure ratio of
overlaid subcell is greater than
the value of this parameter,
half-rate channels are assigned.
Otherwise, full-rate channels
are assigned.
Channel seizure ratio = (Num.
of busy TCHF + Num. of busy
TCHH/2)/(Num. of available
TCHF + Num. of available
TCHH /2) x 100%. This
parameter is valid for the
concentric cell. When the
Allow Rate Selection Based
on Overlaid/Underlaid
Subcell Load is set to Yes, the
TCH Traffic Busy Threshold
(%) is invalid for the concentric
cell.

GUI Value Range: 0~100

Actual Value Range: 0~100

Unit: per cent

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 70
TCHTRIBUSYUNDERLAYTHR

Tch Traffic
Busy Underlay
Threshold

Meaning: Threshold for


determining that the underlaid
subcell is busy. The BSC
assigns channels in the
underlaid subcell to the MS in a
concentric cell. When Allow
Rate Selection Based on
Overlaid/Underlaid Subcell
Load is set to YES, half-rate
channels are assigned if the
channel seizure ratio in the
underlaid subcell exceeds the
value of this parameter, and
full-rate channels are assigned
if the channel seizure ratio in
the underlaid subcell does not
exceed the value of this
parameter.

GUI Value Range: 0~100

Actual Value Range: 0~100

Unit: per cent

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 60
HRIUOLDRATESELALLOW

Load of UL-OL
Cells Rate
Meaning: Whether to enable the
Select Allowed BSC to assign half or full rate
channels to MSs according to
the channel seizure ratio in the
overlaid and underlaid subcells

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: YES


UPRXLEVSMOOTHPARA

Smooth Factor
of Uplink
Meaning: After the existing
Received Level uplink receive level, uplink
receive level after the previous
optimization, and the value of
this parameter are weight-

Parameter ID

Parameter
Name

Parameter Description

averaged, the uplink receive


level after the optimization at
this time is obtained and used
for determing the difference
between the uplink receive
levels.

GUI Value Range: 1~10

Actual Value Range: 0.1~1,


step:0.1

Unit: None

Default Value: None

Recommended Value: 6
UPRXLEVLASTTIME

Duration of
Uplink
Meaning: If the difference
Received Level between uplink receive levels
Differ
of calls within the same
timeslot is greater than Offset
of the difference between
uplink received levels for P
seconds among N seconds, the
call with weak uplink receive
level within the timeslot will be
handed over to another timeslot.
This parameter corresponds to

Parameter ID

Parameter
Name

Parameter Description

P in the P/N criterion.

GUI Value Range: 1~16

Actual Value Range: 1~16

Unit: s

Default Value: None

Recommended Value: 4
UPRXLEVSTATICTIME

Observe Time
of UL RX
Level
Difference

Meaning: If the difference


between uplink receive levels
of calls within the same
timeslot is greater than Offset
of the difference between
uplink received levels for P
seconds among N seconds, the
call with weak uplink receive
level within the timeslot will be
handed over to another timeslot.
This parameter corresponds to
N in the P/N criterion.

GUI Value Range: 1~16

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 1~16

Unit: s

Default Value: None

Recommended Value: 5
QTRUPWRSHARE

Multi-Density
TRX Power
Sharing

Meaning: Whether to use the


statistical multiplexing
algorithm for multi-density
power

GUI Value Range:


NONE(None),
DYNAMIC(Dynamic power
sharing)

Actual Value Range: NONE,


DYNAMIC

Unit: None

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: NONE


MCPAOPTALG

MCPA
Optimization
Switch

Meaning: If the MCPA


Optimization Switch is turned
on, the MCPA priority update
mode is adjusted.

GUI Value Range: OFF(Off),


ON(On)

Actual Value Range: ON, OFF

Unit: None

Default Value: None

Recommended Value: OFF


QTRUDNPWRSTATTIME

Qtru Down
Power
Meaning: The P/N criteria is
Inadequate Stat used to determine low downlink
Time
power for multi-density
carriers. If the downlink power
of a multi-density carrier
remains low during a
consecutive P seconds out of N
seconds, the downlink power of
the multi-density carrier is
considered low. This parameter

Parameter ID

Parameter
Name

Parameter Description

corresponds to the N in the P/N


criteria.

GUI Value Range: 1~16

Actual Value Range: 1~16

Unit: s

Default Value: None

Recommended Value: 5
QTRUDNPWRLASTTIME

Qtru Down
Power
Meaning: The P/N criteria is
Inadequate Last used to determine low downlink
Time
power for multi-density
carriers. If the downlink power
of a multi-density carrier
remains low during a
consecutive P seconds out of N
seconds, the downlink power of
the multi-density carrier is
considered low. This parameter
corresponds to the P in the P/N
criteria.

GUI Value Range: 1~16

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 1~16

Unit: s

Default Value: None

Recommended Value: 3
PWRPRIORALLOW

Power Priority
Allowed

Meaning: When this parameter


is set to YES, The BSC
preferentially uses the TRX
with good power-saving
performance according to the
TRX power priority reported by
the BTS. Smaller priority value
indicates better power saving
quality. If the priority is of a
great value, the BTS closes
TRXs late.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: YES


TIGHTBCCHASSMAINBCCHLEV

Level Thresh
for Assign
BCCH Under
TBCCH

Meaning: During channel


assignment, the assignment of
channels on the BCCH TRXs
depends on the uplink receive
level, quality, and non-BCCH
load. The TCHs are
preferentially assigned on the
BCCH TRXs if the following
conditions are met:
1. The uplink receive level after
filtering is higher than Level
Thresh. for Assigning Main
BCCH Carrier Channel
Under TIGHT BCCH.
2. The uplink receive quality
level after filtering is lower than
Quality Thresh. for Assigning
Main BCCH Carrier Channel
Under TIGHT BCCH.
3. The non-BCCH load is
higher than Intracell Non
Main BCCH Load Threshold
of TIGHT BCCH.

GUI Value Range: 0~63

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 0~63

Unit: dB

Default Value: None

Recommended Value: 30
TIGHTBCCHASSMAINBCCHQUAL

Quality Thresh
for Assign
BCCH Under
TBCCH

Meaning: During channel


assignment, the assignment of
channels on the BCCH TRXs
depends on the uplink receive
level, quality, and non-BCCH
load. The TCHs are
preferentially assigned on the
BCCH TRXs if the following
conditions are met:
1. The uplink receive level after
filtering is higher than Level
Thresh. for Assigning Main
BCCH Carrier Channel
Under TIGHT BCCH.
2. The uplink receive quality
level after filtering is lower than
Quality Thresh. for Assigning
Main BCCH Carrier Channel
Under TIGHT BCCH.
3. The non-BCCH load is
higher than Intracell Non
Main BCCH Load Threshold

Parameter ID

Parameter
Name

Parameter Description

of TIGHT BCCH.

GUI Value Range: 0~7

Actual Value Range: 0~7

Unit: None

Default Value: None

Recommended Value: 1
CHPWRINSUFFALLOWED

Channel Assign
Allow for
Meaning: Whether to allow a
Insuff Power
multi-density TRX board, that
uses the dynamic power sharing
algorithm to assign channels, to
assign a channel to an MS when
the remaining power on the
multi-density TRX board is less
than the power required by the
MS. If this parameter is set to
YES, a multi-density TRX
board that uses the dynamic
power sharing algorithm to
assign channels cannot assign a
channel to an MS when the
remaining power on the multidensity TRX board is less than
the power required by the MS.If
this parameter is set to NO, a

Parameter ID

Parameter
Name

Parameter Description

multi-density TRX board that


uses the dynamic power sharing
algorithm to assign channels
can assign a channel to an MS
when the remaining power on
the multi-density TRX board is
less than the power required by
the MS.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: NO
FREQLOADSHARETRAFFTHRSH

GSM900 Band
Traffic Load
Share
Threshold

Meaning: Threshold for load


sharing in the 900 MHz
frequency band. Assume that an
MS supports multiple subbands in the 900 MHz
frequency band. If the cell load
is equal to or less than this
threshold, the BSC does not
consider the priority levels of
the P-GSM, E-GSM, and R-

Parameter ID

Parameter
Name

Parameter Description

GSM sub-bands during channel


assignment. If the cell load is
greater than this threshold, the
BSC assigns channels
according to the priority levels
of the P-GSM, E-GSM, and RGSM sub-bands. That is, if the
MS supports the P-GSM, EGSM, and R-GSM sub-bands
and the cell is configured with
the TRXs in the P-GSM, EGSM, and R-GSM sub-bands,
the BSC assigns the channels in
the TRXs of the R-GSM subband preferentially.

GUI Value Range: 0~100

Actual Value Range: 0~100

Unit: per cent

Default Value: None

Recommended Value: 25
NAMRLFRMTRXALLOWED

Assign NonAMR User


Loose Fre.
Reuse TRX

Meaning: Whether to
preferentially allocate loose
multiplexing frequencies to

Parameter ID

Parameter
Name

Parameter Description

non-AMR users

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: NO
IBCAALLOWED

IBCA Allowed
Meaning: Whether to enable the
IBCA algorithm

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: NO
IBCAUSRDYNCMEASURENCELL

IBCA User
Dyn Measure
Neighbor Cell

Meaning: Whether a single


IBCA MS can dynamically
measure the neighboring cells.
When this parameter is set to
YES, the neighboring cells
where IBCA Dynamic
Measure Neighbor Cell Flag
is set to YES are dynamically
measured. Dynamic
measurement on neighboring
cells is mutually exclusive to
directed retry. When this
parameter is set to YES, it is
recommended that Direct
Retry be set to NO.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: NO
IBCAUSEDIUOSUBLAY

IUO IBCA
Allowed

Meaning: Whether to enable the


IBCA algorithm for the overlay
and underlay of an IUO cell

GUI Value Range:


NO(Disabled in OL and UL
subcell), UNDER(Enabled in
UL subcell), INNER( Enabled
in OL subcell), YES(Enabled in
OL and UL subcell)

Actual Value Range: NO,


UNDER, INNER, YES

Unit: None

Default Value: None

Recommended Value: UNDER


IBCASOFTBLKSWITCH

IBCA Soft
Block Switch

Meaning: Whether to deny the


access of a call when none of
the MAIO evaluation results
meets the C/I ratio requirement
of the call during channel

Parameter ID

Parameter
Name

Parameter Description

assignment

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: NO
IBCAFRSOFTBLKTHRD

IBCA FR/EFR
Soft Block
Threshold

Meaning: Minimum C/I ratio


that IBCA FR/EFR services
allow. An idle channel can be
assigned to such a service only
when the C/I ratio of the idle
channel is greater than this
threshold. In addition, a new
call associated with such a
service can be established only
when the call does not decrease
the C/I ratio of the established
calls to a value less than this
threshold.

Parameter ID

Parameter
Name

Parameter Description

GUI Value Range: 0~23

Actual Value Range: 0~23

Unit: dB

Default Value: None

Recommended Value: 10
IBCAHRSOFTBLKTHRD

IBCA HR Soft
Block
Threshold

Meaning: Minimum C/I ratio


that IBCA HR services allow.
An idle channel can be assigned
to such a service only when the
C/I ratio of the idle channel is
greater than this threshold. In
addition, a new call associated
with such a service can be
established only when the call
does not decrease the C/I ratio
of the established calls to a
value less than this threshold.

GUI Value Range: 0~23

Actual Value Range: 0~23

Parameter ID

Parameter
Name

Parameter Description

Unit: dB

Default Value: None

Recommended Value: 13
IBCAAFRSOFTBLKTHRD

IBCA AMR FR
Soft Block
Meaning: Minimum C/I ratio
Threshold
that IBCA AMR FR services
allow. An idle channel can be
assigned to such a service only
when the C/I ratio of the idle
channel is greater than this
threshold. In addition, a new
call associated with such a
service can be established only
when the call does not decrease
the C/I ratio of the established
calls to a value less than this
threshold.

GUI Value Range: 0~23

Actual Value Range: 0~23

Unit: dB

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: 4
IBCAAHRSOFTBLKTHRD

IBCA AMR
HR Soft Block
Threshold

Meaning: Minimum C/I ratio


that IBCA AMR HR services
allow. An idle channel can be
assigned to such a service only
when the C/I ratio of the idle
channel is greater than this
threshold. In addition, a new
call associated with such a
service can be established only
when the call does not decrease
the C/I ratio of the established
calls to a value less than this
threshold.

GUI Value Range: 0~23

Actual Value Range: 0~23

Unit: dB

Default Value: None

Recommended Value: 10
IBCAWAFRSOFTBLKTHRD

IBCA WAMR
FR Soft Block

Meaning: The lowest C/I ratio

Parameter ID

Parameter
Name

Parameter Description

Threshold
that can be tolerated by IBCA
WAMR FR. The C/I ratio of an
idle channel must be larger than
this parameter. Otherwise, it
cannot be assigned. In addition,
the system does not allow a
newly-established call causing
the C/I ratio of existing calls to
be lower than this parameter.

GUI Value Range: 0~23

Actual Value Range: 0~23

Unit: dB

Default Value: None

Recommended Value: 5
IBCASOFTBLKSAICOFF

IBCA Soft
Block SAIC
Offset

Meaning: MSs that support


SAIC can tolerate a lower
carrier-to-interference ratio.
This variable indicates the
downward adjustment step of
the soft blocking threshold of
SAIC MSs.

Parameter ID

Parameter
Name

Parameter Description

GUI Value Range: 0~23

Actual Value Range: 0~23

Unit: dB

Default Value: None

Recommended Value: 1
IBCAMAXINTFSRCNUM

IBCA Max.
Interference
Source Num.

Meaning: The IBCA


interference evaluation process
only considers the interference
of the strongest N existing calls
on the newly-established call
being evaluated. This parameter
corresponds to the abovementioned N.

GUI Value Range: 5~40

Actual Value Range: 5~40

Unit: None

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 20
IBCADLPATHLOSSOFF

IBCA
Downlink Path
Loss Offset

Meaning: Difference between


uplink and downlink path
losses, which is used to
estimate the downlink path loss
of a call when the downlink
path loss cannot be computed
directly according to a
measurement report. This
parameter is configured
according to the combined loss
and hierarchical dual-antenna
gain (3 dB) of the BTS.
IBCA Downlink Path Loss
Offset = combined loss of BTS
+ hierarchical dual-antenna gain
of BTS (3 dB)

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: 7
IBCAIUOPATHLOSSOFF

IBCA IUO Path


Loss Offset
Meaning: In an IUO cell (or a
CoBCCH cell), the path loss of
an MS to the serving cell or a
neighboring cell measured on
the underlay is used together
with this parameter to estimate
the path loss on the overlay.
IUO path loss compensation =
Combiner insert loss difference
+ Path loss difference due to the
use of different antennas + Path
loss difference due to different
frequency selectivity. This
value is calculated based on the
IUO level values measured by
field engineers. When different
antennas are used by the
overlay and underlay, the level
must be measured at multiple
locations.

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: 4
IBCASCELLPATHLOSS

IBCA Service
Cell Pathloss

Meaning: Use this parameter


when the path loss of an MS to
serving cells cannot be
measured based on the existing
measurement results

GUI Value Range: 0~160

Actual Value Range: 0~160

Unit: dB

Default Value: None

Recommended Value: 110


IBCAPATHLOSSOFF

IBCA Pathloss
Offset

Meaning: When the path loss of


an MS to a neighboring cell
cannot be measured based on
the existing measurement
results, it is estimated based on
the path loss of the MS to the
serving cell plus the IBCA path
loss offset.

Parameter ID

Parameter
Name

Parameter Description

GUI Value Range: 0~50

Actual Value Range: 0~50

Unit: dB

Default Value: None

Recommended Value: It is
recommended that you set the
path loss offset of layer 1
neighboring cells of the serving
cell to 15 dB and that of other
neighboring cells to 25 dB.
IBCACALLINFOFILTERLEN

IBCA Call
Information
Filter

Meaning: Number of
measurement reports sampled
for averaging path loss. A single
measurement report may not
reflect the actual network
situations accurately. Therefore,
the BSC needs to average the
measured values in several
successive measurement reports
to reflect the radio environment.

GUI Value Range: 1~4

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range:


TCH:480~1920, step:480;
SDCCH:470~1880, step:470

Unit: ms

Default Value: None

Recommended Value: 4
LOOSESDCCHLOADTHRED

IBCA Loose
Trx SDCCH
Meaning: When the load of an
Load Threshold SDCCH on the TRX that is in
loose frequency reuse and is in
the compatible band of the
BCCH is lower than this
threshold, the SDCCH is
preferably allocated.

GUI Value Range: 0~100

Actual Value Range: 0~100

Unit: per cent

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: 80
TIGHTSDCCHRXLEVTHRED

IBCA Tight Trx


SDCCH Rxlev Meaning: If the SDCCH load
Threshold
on the TRXs of the compatible
BCCH in loose frequency reuse
pattern is greater than the IBCA
Loose Trx SDCCH Load
Threshold, and when the
uplink receive level from the
MS to the BTS is greater than
the threshold, the SDCCHs on
the TRXs of the compatible
non-BCCH are preferentially
assigned. Otherwise, the
SDCCHs on the TRXs of the
compatible BCCH are
preferentially assigned.

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Recommended Value: 40

Parameter ID

Parameter
Name

WAITSDCCHIDLETIMER

IBCA Wait
SDCCH Idle
Timer

Parameter Description

Meaning: When the dynamic


PDCH needs to use MAIO of
the SDCCH, the SDCCH is not
allowed to be assigned to new
calls within the value of the
parameter. After the timer
expires, check whether the
SDCCH is idle. If the SDCCH
is idle, MAIO of the SDCCH is
allowed to be preempted. If the
channel is not idle, the MAIO is
not allowed to be preempted.

GUI Value Range: 0~60

Actual Value Range: 0~60

Unit: s

Default Value: None

Recommended Value: 4
IBCAICDMSWITCH

IBCA ICDM
Switch

Meaning: Whether to enable the


ICDM algorithm for the cell.
The ICDM algorithm helps to
improve the precision in
estimating the path loss of an
IBCA neighbor cell and to
increase the efficiency of the

Parameter ID

Parameter
Name

Parameter Description

IBCA algorithm.

GUI Value Range: NO(No),


YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: None

Recommended Value: YES


IBCAPLFILTFACTOR

IBCA Path
Lose Filter
Factor

Meaning: Considers the


influence of history path loss
information during the
calculation of the ICDM
algorithm path loss. The smaller
the filtering coefficient, the
smaller the influence of history
path loss; on the other hand, the
larger the filtering coefficient,
the larger the influence of
history path loss.

GUI Value Range: 0~10

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 0~10

Unit: None

Default Value: None

Recommended Value: 6
IBCANCELLPATHLOSSESTIMATE

IBCA Pathloss
Est of Non. MR Meaning: Estimates the receive
Ncell
level of the unmeasured IBCA
neighboring cells. When a
consecutive IBCA Non
Measurement Ncell Stat. Num
measurement reports cover less
than six neighboring cells (or
the number of the reported
neighboring cells is smaller
than that of the actually
configured neighboring cells),
this parameter is used to
estimate the receive level of the
unmeasured IBCA neighboring
cells. The estimated value is
IBCA Pathloss Est of Non.
MR Ncell. Otherwise, the
signal strength of the
unmeasured IBCA neighboring
cells is the signal strength of the
measured neighboring cells
(including non-IBCA
neighboring cells) subtracted by
IBCA RxLev Offset.

Parameter ID

Parameter
Name

Parameter Description

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Recommended Value: 0
IBCANONMEANCELLSTATNUM

IBCA Non
Measurement
Ncell Stat.
Num

Meaning: Estimates the receive


level of the unmeasured IBCA
neighboring cells. When a
consecutive IBCA Non
Measurement Ncell Stat. Num
measurement reports cover less
than six neighboring cells (or
the number of the reported
neighboring cells is smaller
than that of the actually
configured neighboring cells),
this parameter is used to
estimate the receive level of the
unmeasured IBCA neighboring
cells. The estimated value is
IBCA Pathloss Est of Non.
MR Ncell. Otherwise, the
signal strength of the
unmeasured IBCA neighboring
cells is the signal strength of the
measured neighboring cells
(including non-IBCA

Parameter ID

Parameter
Name

Parameter Description

neighboring cells) subtracted by


IBCA RxLev Offset.

GUI Value Range: 0~16

Actual Value Range: 0~16

Unit: None

Default Value: None

Recommended Value: 4
IBCAMAIOUSMTD

IBCA MAIO
Using Method

Meaning: Determines the


MAIO selection method for
each timeslot. The Optimal
MAIO policy selects the
optimal MAIO being evaluated,
while the Random MAIO
policy randomly selects a
MAIO out of qualified MAIOs.

GUI Value Range: 0(Max.


optimized MAIO),
1(Randomization MAIO)

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 0, 1

Unit: None

Default Value: None

Recommended Value: 0
IBCATARGETCIRTHRSH

IBCA MAIO
Target C/I
Threshold

Meaning: Whether a MAIO


meets the access requirement.
When the C/I ratio of a MAIO
is higher than this threshold, the
MAIO can be assigned to the
call being processed.

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: None

Default Value: None

Parameter ID

Parameter
Name

Parameter Description

Recommended Value: 20
IBCAINITPCRXLEVDLOFFSET

IBCA Init.
Power Control
RexLevDL
Offset

Meaning: Adds a specified


offset to the downlink target
receive level when power
control algorithm III is used to
calculate the initial transmit
power of a BTS in the IBCA
function

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Recommended Value: 0
IBCAINITPCRXLEVULOFFSET

IBCA Init.
Power Control
RexLevUL
Offset

Meaning: Adds a specified


offset to the uplink target
receive level when power
control algorithm III is used to
calculate the initial transmit
power of an MS in the IBCA
function

Parameter ID

Parameter
Name

Parameter Description

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: dB

Default Value: None

Recommended Value: 0
IBCAINITPCRXQUALDLOFFSET

IBCA Init. Pwr


Ctrl Rx Qual
Meaning: Adds a specified
DL Offset
offset to the downlink target
receive quality when power
control algorithm III is used to
calculate the initial transmit
power of a BTS in the IBCA
function

GUI Value Range: 0~22

Actual Value Range: 0~22

Unit: dB

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 0
IBCAINITPCRXQUALULOFFSET

IBCA Init. Pwr


Ctrl Rx Qual
Meaning: Adds a specified
UL Offset
offset to the uplink target
receive quality when power
control algorithm III is used to
calculate the initial transmit
power of an MS in the IBCA
function

GUI Value Range: 0~22

Actual Value Range: 0~22

Unit: dB

Default Value: None

Recommended Value: 0
LOWRXLEVOLFORBIDSWITCH

Allocate OL
Channel Based
on RX Level

Meaning: Whether to assign


overlay channels in an IUO cell
based on the receive level

Parameter ID

Parameter
Name

Parameter Description

conditions

GUI Value Range: OFF(Off),


ON(On)

Actual Value Range: OFF, ON

Unit: None

Default Value: None

Recommended Value: You are


advised to disable this function
in the co-BCCH cell with the
inter-site distance not more than
1500m.
ASSOLRXLEVOFFSET

Assign to
Overlayer
RxLev Offset

Meaning: Offset relative to the


level threshold for determining
whether to assign a channel in
the overlaid subcell

GUI Value Range: 0~61

Actual Value Range: 0~61

Parameter ID

Parameter
Name

Parameter Description

Unit: dB

Default Value: None

Recommended Value: 35
HOOLRXLEVOFFSET

Handover to
Overlayer
RxLev Offset

Meaning: If the cell is an


enhanced concentric cell, this
parameter with the current
downlink received signal level
and UtoO HO Received Level
Threshold determines whether
to assign a channel in the
underlaid subcell to the intraBSC incoming handover to the
concentric cell or intra-BSC
inter-cell handover.
If the cell is an ordinary
concentric cell, this parameter
with the current downlink
received signal level, RX_LEV
Threshold, and RX_LEV
Hysteresis determines whether
to assign a channel in the
underlaid subcell to the intraBSC incoming handover to the
concentric cell or intra-BSC
inter-cell handover.

GUI Value Range: 0~61

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 0~61

Unit: dB

Default Value: None

Recommended Value: 32
IBCASUBCHNHANDOVERALLOWED

IBCA SubChannel
Handover
Allowed

Meaning: Whether the


handover of the calls on the
single channels is allowed
(single channels are the two
half-rate sub-channels on a
timeslot, in which only one is in
the occupied state) when single
channels are to be adjusted to a
full-rate channel. When this
parameter is set to ON, the
handover of the calls on the
single channels is allowed; if
this parameter is set to OFF, the
handover of the calls on the
single channels is not allowed.
This parameter is valid only
when the IBCA algorithm is
enabled and full rate is
preferred for the newly
established call.

GUI Value Range: OFF(Not


Allowed), ON(Allowed)

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: OFF, ON

Unit: None

Default Value: None

Recommended Value: OFF


IBCAFORCEDBTSSYNCALLOWED

IBCA Forced
BTS
Synchronizatio
n Allowed

Meaning: Whether the IBCA


forced BTS synchronization is
allowed. When this parameter is
set to YES, the synchronization
procedure is performed even
though the BTSs are
insynchronous. When this
parameter is set to NO, the
existing procedure, either the
synchronization procedure or
the out-of-synchronization
procedure, is performed as
required. Note that the
synchronization status of the
IBCA neighboring cells is
determined by the internal
software parameters of the
IBCA neighboring cells, that is,
if this parameter in IBCA
neighboring cells is set to YES,
the IBCA neighboring cells are
considered to be always
synchronous; otherwise, the
IBCA neighboring cells are
considered to be out of

Parameter ID

Parameter
Name

Parameter Description

synchronization.

GUI Value Range: OFF(Not


Allowed), ON(Allowed)

Actual Value Range: OFF, ON

Unit: None

Default Value: None

Recommended Value: OFF


IBCAFLEXTSCALLOWED

IBCA Flexible
TSC Allowed

Meaning: Whether the IBCA


flexible TSC function is
enabled. When this parameter is
set to NO, the flexible TSC
function is disabled and the
configured TSC is used. When
the BTS supports Flex TSC and
this parameter is set to YES, the
flexible TSC function is
enabled.

GUI Value Range: OFF(Not


Allowed), ON(Allowed)

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: OFF, ON

Unit: None

Default Value: None

Recommended Value: OFF


IBCAASSWAITMEASURERPTTIME

IBCA Assign
Waiting Mr
Time

Meaning: Length of the timer


for a new call to wait for the
measurement report (MR) on
the signaling channel when
dynamic measurement of the
BA2 list is enabled during
assignment. If this parameter is
set to 0, dynamic measurement
of the BA2 list is not enabled
during assignment.

GUI Value Range: 0~20

Actual Value Range: 0~10,


Step: 0.5

Unit: s

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 4
IBCANHOASSWAITMEASURERPTTIM
E

IBCA Natural
HO Waiting Mr Meaning: Length of the timer
Time
for a call to measure the path
loss in the neighboring cell with
strong interference of the target
cell. The call to be handed over
needs to measure the path loss
before initiating the handover to
the target cell when dynamic
measurement of the BA2 list is
enabled during the normal
handover. When this parameter
is set to 0, dynamic
measurement of the BA2 list is
not enabled in the normal
handover, and the parameter
"Wait Time for Valid MRs in
IBCA HO" is invalid.

GUI Value Range: 0~20

Actual Value Range: 0~10,


Step: 0.5

Unit: s

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 5
IBCAEHOASSWAITMEASURERPTTIM
E

IBCA Urgent
HO Waiting Mr Meaning: Length of the timer
Time
for a call to measure the path
loss in the neighboring cell with
strong interference of the target
cell. The call to be handed over
needs to measure the path loss
before initiating the handover to
the target cell when dynamic
measurement of the BA2 list is
enabled during the emergency
handover. When this parameter
is set to 0, dynamic
measurement of the BA2 list is
not enabled in the emergency
handover, and the parameter
"Wait Time for Valid MRs in
IBCA HO" is invalid.

GUI Value Range: 0~20

Actual Value Range: 0~10,


Step: 0.5

Unit: s

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 0
IBCAHOASSWAITMEASURERPTTIME

IBCA HO
Waiting
Effective Mr
Time

Meaning: Length of the timer


for a call to wait for other valid
MRs after receiving the first
valid MR of the target cell if
dynamic measurement of the
BA2 list is enabled during
handover. When this parameter
is set to 0, the call does not wait
for other MRs after receiving
the first MR of the target cell.

GUI Value Range: 0~20

Actual Value Range: 0~10,


Step: 0.5

Unit: s

Default Value: None

Recommended Value: 2

Parameter ID

Parameter
Name

CIRESTVALUE

C/I Estimate
Value

Parameter Description

Meaning: This parameter


specifies the estimated carrierto-interference ratio of a new
call. It is used for the Huawei
power control algorithm III to
calculate the power of the call.

GUI Value Range: 0~22

Actual Value Range: 0~22

Unit: dB

Default Value: None

Recommended Value: 22
IBCANEWCALLCIROFFSET

Target CIR
Offset of IBCA Meaning: When the IBCA
New Call
algorithm is enabled, this
parameter is used to calculate
the target CIR of a new call.
The formula is as follows:
Target CIR of a new call =
Target CIR in use + Target CIR
Offset of IBCA New Call

GUI Value Range: 0~30

Parameter ID

Parameter
Name

Parameter Description

Actual Value Range: 0~30

Unit: dB

Default Value: None

Recommended Value: 7
IBCAOPRREVISEFACTOR

Corrected
Factor of IBCA Meaning: When the IBCA
Priority
algorithm is enabled and the
HSN is not 0, the IBCA priority
and the SDCCH/PDCH priority
are divided by this corrected
factor respectively to reduce the
weight of IBCA priority. In
addition, the priority of the
interference band is considered.

GUI Value Range: 0~63

Actual Value Range: 0~63

Unit: None

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value: 0
IBCACALLTARGETCIROFFSET

Target CIR
Offset of IBCA Meaning: When the IBCA
Set-up Call
algorithm is enabled, this
parameter is used to calculate
the target CIR of an existing
call. The formula is as follows:
Target CIR of an existing call =
Target CIR in use + Target CIR
Offset of IBCA Set-Up Call.

GUI Value Range: 0~14

Actual Value Range: 0~14

Unit: dB

Default Value: None

Recommended Value: 4
IBCACALLSOFTBLOCKTHOFFSET

IBCA Set-up
Call Soft Block Meaning: When the IBCA
Threshold
algorithm is enabled, this
Offset
parameter is used to calculate

Parameter ID

Parameter
Name

Parameter Description

the actual soft blocking


threshold of an existing call.
The formula is as follows:
Actual soft blocking threshold
of an existing call = Configured
soft blocking threshold of an
existing call - IBCA Set-up Call
Soft Block Threshold Offset.

GUI Value Range: 0~14

Actual Value Range: 0~14

Unit: dB

Default Value: None

Recommended Value: 0
IBCAICDMRELEVOFFSET

IBCA ICDM
Initial Level
Offset

Meaning: In the ICDM matrix


algorithm, the signal strength
(0-63) is divided into 10 levels.
The signal strength that is
smaller than or equal to the
value of this parameter is at the
initial level.

Parameter ID

Parameter
Name

Parameter Description

GUI Value Range: 0~31

Actual Value Range: 0~31

Unit: dB

Default Value: None

Recommended Value: 10
CELLOPPWRGRP

Cell Operator
Power Group

Meaning: Power of each


passage on the MRRU in the
cell. When multiple operators
are configured on an MRRU,
the parameter specifies the
power of each operator on the
MRRU.

GUI Value Range:


OP1(Operator 1), OP2(Operator
2), OP3(Operator 3),
OP4(Operator 4), NONE(Not
Shared)

Actual Value Range: OP1, OP2,


OP3, OP4, NONE

Parameter ID

Parameter
Name

Parameter Description

Unit: None

Default Value: None

Recommended Value: 255


LOADSTATYPE

Type of Cell
Load
Calculation

Meaning: This parameter


specifies whether the dynamic
PDCHs that have been
converted into the PDCHs are
considered during the
calculation of the current cell
load.

GUI Value Range:


NOTSTADYNPDCH(Not
count dynamic PDCH),
DYNPDCHASOCCUPY(Coun
t dynamic PDCH(Occupy)),
DYNPDCHASIDLE(Count
dynamic PDCH(Idle))

Actual Value Range:


NOTSTADYNPDCH,
DYNPDCHASOCCUPY,
DYNPDCHASIDLE

Unit: None

Parameter ID

Parameter
Name

Parameter Description

Default Value: None

Recommended Value:
DYNPDCHASIDLE

Example
To set the advanced channel management parameters of the cell (Index Type =
BYID;
Cell Index = 0; TCH Traffic Busy Threshold = 100), run the following command:
SET GCELLCHMGAD: IDTYPE=BYID, CELLID=0, TCHBUSYTHRES=100;