Sei sulla pagina 1di 22

National Cooling Towers

Quality Certified Company

Selection of right Cooling Towers and Chillers


for your hot water processing in plant.
Leading Manufactures ,Suppliers And Exporters Of

COOLING TOWERS and CHILLING PLANTS

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Company Information
Name of CEO : Mr. S. Chandrashekhar
Establishment Year : 1990
Business Type : Manufacturer & Merchant Exporter
No. of Employees : 100-150
Annual Sales : 8 to 10 Core INR.
Market Cover :

All over India and World Wide Markets mainly Africa and Middle
East

FRP Cooling Towers, Cooling Towers, Air Cooled and


Water Cooled Chilling Plants, Brine Chillers & Air Blast
Products We Offer :
Coolers etc.

Member Of :

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Our Product Range


Product Range

Capacity

a)

FRP Induced Draught Cooling Towers

03 to 1000 TR

b)

Timber Cross Flow & Counter Flow Cooling Towers

25 TR and Above

c)

RCC Mechanical & Hyperbolic Cooling Towers

1000m3 / hr and Above as require

d)

Air Cooled Chilling Plants

01 TR To 50 TR

e)

Water Cooled Chilling Plants

03 TR TO 350 TR

f)

Oil Chillers

01 TR TO 50 TR

g)

Air Blast Coolers

5 KW Upwards

h)

Industrial Screw Chillers

50 TR to 500 TR

i)

Multi Compressor Chillers ( Tandom Chiller)

50 TR to 80 TR

j)

Brine Process Cooling System ( Brine Chiller)

1 TR and Above as require

i)

Screw Compressor Chiller

Above 50 TR

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

We are supplying to process industries like


01.

HVAC

02.

Steel Plant.

03.

Chemical & Fertilizer industries

04.

Cement Industries.

05.

Pharmaceutical Industries

06.

Machine Building Industries.

07.

Petroleum Industries

08.

Air Condition & Refrigeration Plant.

09.

Plastic & Rubber Industries.

10.

Automobile Industries.

11.

Induction Furnaces.

12.

Process Plants.

13.

Glass Industry.

14.

Air Compressions.

15.

Oxygen Plants.

16.

Breweries & Distilleries.

17.

Forgings Industries.

18.

Paper Industries.

19.

Textile Industries.

20.

Food Processing Industries.

21.

Sugar Industries.

22.

Anodizing

23.

D.G. Sets

24.

Power Plants

+ many more process industries where


hot water is need to be cool for
process

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Incepted in the year 1990, we at National Cooling Towers (ISO 9001:2008 certified company), have
become one of the recognized firm engaged in designing manufacturing and erection of an exclusive
range of reliable, tailor-made Water Cooling Towers (FRP Induced Draft Counter Flow, Timber
Induced Draft Cross and Counter Flow, RCC Induced Draft Cross and Counter Flow )
plus Air Blast Coolers and Air and Water Chilling Plants.
Owing to our state-of-the-art manufacturing unit comprising latest machinery, we are able to fabricate
high quality Cooling Towers & Air Blast Coolers and Chilling Plants as per CIT-USA,CE and
ISO 9001:2008 standards. We undertake site supervision, erection, testing & commissioning. Our
experience and qualified sales and service staff work in partnership with you to provide technical advice
and field service support.
National Cooling Towers pays great attention to detail, using only high quality materials and
submitting the produced machines and equipments to numerous checks and inspections. In this way, we
are succeeding in combining reliability, high technology and simplicity of use with Zero maintenance.
We have a symbolic presence across the globe in the industry as our supplies of Cooling Towers have
touched more than 60000 and Chilling Plants more than 5000. Products deployed across the India
and globe in high-profile customers.
5

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Approved by

National Cooling Tower make FRP Cooling Tower Detail View

6
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Cooling Tower - Classification

7
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

National Cooling Tower ( Single Cell) Block Diagram

Email: rajguru.nct@gmail.com

or

Phone : +91 9833094837

National Cooling Tower ( Twin Cells) Block Diagram

Email: rajguru.nct@gmail.com

or

Phone : +91 9833094837

10

Email: rajguru.nct@gmail.com

or

Phone : +91 9833094837

Approved by

National Cooling Tower make Air and Water Chillers Detail View

11

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Why We Are ( Techno Commercial Compliance as per Your Expectations )


State-of-the-art infrastructure
1) We are using raw materials that have the appropriate properties and high quality are attractive and
a necessity to ensure that the end product maintains a high standard and is suitable for its purpose.
2) 38000 + Satisfied Clients
3) GREEN BUILDING Installations
4) Major Exports in Africa, Middle East and Europe.
5) The demands are high, the problems varied. Our aim? To deliver a perfect product that meets very
exacting specifications.
6) Cooling System Design as per your requirement.
7) Cooling Towers are FRP make, having zero maintenance.
8) A close approach Next Page
12
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Why We Are ( Techno Commercial Compliance as per Your Expectations )


9)Greater thermal efficiency
10)Higher energy saving
11)Ease of maintenance
12) Lower Drift Loss
13)Option for Cooling Towers with Centrifugal Fans for Noiseless Operation
14)Longer working life for fans and motors, since handling dry air
15)Supply & Install at your site.
16)Upgrade/Reconstruction advised by our expertise.
17)Reconditioning as per your requirement.
18)Maintenance, repair and operations ( MRO)
19)Performance Testing & Vibration Analysis
20)Inspection Support and Training
13

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

14

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

15

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Why Counter Flow is always better than Cross Flow. Page 1 based on Practical ( Important
points to be consider before buying)
A) National Induced Draft Counter Flow Cooling
Tower:In the Induced Draft Counter Flow, always the dry
air is in contact with the cool water emerging out from
the PVC fills. That means when the air passes
through the PVC fills the proper water to air contact
occurs and the water evaporate. Thus it loses it heat
energy and the moist air is thrown out which will not
be re-circulating because the total height of the
cooling tower is maintained for the fresh air to flow
from the bottom.

Induced Draft Counter Flow Cooling Tower:-The


moist air thrown out through the fan stack takes a
chance in re-circulating through the air entry sides
because of high velocity and the low fan stack height.
So always cross flow cooling towers does towers
does require higher installed power then counter flow
cooling tower. NATIONAL Cooling Tower required
1Ft. to 3Ft. clear space on each side. This results
in considerable space saving.

16

A) Other Cross Flow Cooling Tower


It is a known fact that the cross flow cooling towers have the
air entry from sides throughout & the distribution pans kept
above the heat transfer area from the pan the hot water flow
through the holes provided. The first layer of hot water which is
falling down get in contact with the fresh dry air. It then extracts
heat from the hot water and becomes moist and allows hot water
to evaporate. Then hot water loses its heat and is collected in the
basin. The second layer of hot water which is also flowing from
the pan comes in contact with the same air which is moist and is
with higher temperature. The rate of evaporation decreases
and the water is not collected to the design outlet
temperature because the approach decreases inside the cooling
tower which effects the other layers of water & as the air passes
inside the efficiency decreases & when the cold water is collected
from the basin the temperature of water shall be the mean
temperature of all the layers.

Cross flow cooling tower have air inlet through louvers on


sides and the air discharge is on the top. For proper
performance of the tower above 6Ft. to 7Ft. clear space is
required in front of the fan. For air inlet

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Why Counter Flow is always better than Cross Flow. Page 2 based on Practical ( Important)
There are no louvers in NATIONAL Cooling Towers.

Cross flow cooling tower have louvers. This increase


maintenance of the towers and the static pressure drop. Also the
louvers are prone to breakage and therefore have to be replaced.

NATIONAL do not have water distribution exposed to the


atmosphere.

Cross flow cooling towers have water distribution on top & header
type which is exposed to sun. Due to this, chances of algae
formation are increased. Also because of the exposed water
distribution, dust tends to settle on the top and is circulated with
cooling water. The dust and algae tend to depositing in air
condenser chiller and compressor jackets, affecting heat transfer
whereby discharge pressure will be more effects the performance
of the air-conditioning plants.
The removal of packs in cross flow cooling tower is very
cumbersome & time consuming.

NATIONAL Cooling Towers have Two inspection cum


service windows. Through these windows the water
spray and the PVC Fills packs can be observed and
corrective action if required can be taken immediately.
Through these windows packs can be removed easily for
cleaning without disturbing the casing of the tower.
NATIONAL FRP Cooling Tower is very compact and very
light weight.
For National Cooling Towers Service & Maintenance is
considerably reduced because fan is the only moving part
in the cooling tower. The fills eliminator can easily be
approached from the inspection window without
disturbing the cooling tower casing.
NATIONAL Cooling Towers have totally FRP casing. FRP
materials are corrosive proof and does not warp and
deteriorate and very compact, height, weight and user
friendly by increasing the total efficiency of the systems
by ensuring the air flow from all the four sides from the
bottom portion and bringing proper contact between
water film and air stream.

Space requirement for cross flow cooling tower compare to


NATIONAL FRP Cooling Tower is more

17
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Comparative Evaluation Study between FRP Induced Draught Counter Flow Cooling
Tower and Natural Draught Fan Motor Less Cooling Tower ( Important)
Sr. No
1
2
3

4
5
6

18

FRP Induced Draught Counter Flow


Cooling Tower

Natural Draught Fan Motor Less Cooling Tower

Dissipation of latent heat load guaranteed Can not guarantee dissipation of latent heat load. The dissipation
during any climatic conditions.
depend upon wet and dry bulb temperature.
Desired temperature dropped
The temperature dropped is not constant and temperature dropped
guaranteed.
can not be achieved.
Evaporation and drift losses are
Evaporation and drift losses percentage average around 2.00% to
maximum 0.80% to 1.00% on your
2.50% on circulation of water flow rate or even more depending
circulation of flow rate.
upon atmospheric seasonal wet and dry bulb temperature and due
to wind velocity and height of Cooling Tower.
Less area required and limited height.
Required more area and higher height.
Due to limited height the pump head is
also required less in capacity.
Energy saving due to limited height,
single header with 1/2 dia Spray Nozzles
minimum quantity of Nozzles required.
Foreign particles accumulated is
negligible due to enclose body of Cooling
Tower.

Cooling Tower efficiency guaranteed


throughout working performance due to
mechanical draught system.

Height is more. The pump head is also required in higher capacity.


Energy required more to keep constant pressure for multiple water
distribution header and multiple No. of Nozzles required to spray
the water to achieve breakage of water.
Maximum open area. The accumulation of foreign particles is
higher percentage, due to this Air-contaminated foreign particles
the efficiency of Cooling Tower decreases day by day and chance
of getting clogged of your process system incase any solid
structural particles come into contact of inside of Cooling Tower.
No guarantee of performance due to Natural Draught climatic
condition.

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

COMPARATIVE STUDY BETWEEN Square Shaped and Bottle or Round Shape Cooling Towers
SQUARE SHAPED
National design Cooling Tower is ONE peace mould construction.
Square shaped the uniform thickness are maintained. We provide
Pyramid type dome.
Fix header water distribution system has uniform water distribution
without loosing the pressure dropped due to fixed header system.
No tension bar and no Ball Bearing are required.

Fix header water distribution system with water inlet on the top and
outlet in the basin is easy to maintain within limited time.

BOTTLE (ROUND) SHAPED


No. of segments are 10 to 12 and above casing. These segments are
bottled shaped and neck type dome there are always possibilities of
uneven thickness of casing.
The round shaped Cooling Tower consists of Rotary Sprinkler assembly
with Ball Bearing System and Metal Tension Bar. The Cooling Tower
water always contaminated with CaCo3. Due to contaminated water the
bearings are likely to get jammed, corroded, worn out faster and over a
period of used the tension of spring also get loose and its likely the
reduces the desired ROTATION.
The water distribution system is on the bottom. To maintain this system
is very difficult and consuming maximum time for servicing due to Arm
Pipe gravity pressure system.
Installation of Bottled shaped Cooling Tower are provided with V bar
metal support and in turn the V bar metal support are rested on RCC
Pillars, Leaving the entire Cooling Tower hanging above the RCC
Surface floor with the result the chances of vibrations are more.
You need to call trained personnel of Cooling Tower Company only.

F Installation of the square shaped Cooling Tower is simple and


easy. The Cooling Tower without FRP Basin can be rested on RCC
basin. No chances of vibration, since the entire Cooling Tower rest
on RCC basin, which maintain the uniform load distribution.
To maintain Square Shaped Cooling Tower any of your workers can
do the job due to the simple system.
Nozzles are provided with 2.5 Diameter the turbulence effect for
With Rotary system water is just dropping from PVC Arm pipes with thick
water spray is absolute uniform over the Fills area. No possibilities layer of water without getting water sprayed over the fills area, the
of air pocket development.
chances of air pocket developments are maximum. Due to rotation of
sprinkler Arms is being obstacle for dissipation of heat load generated in
the Cooling Tower area. Due to the pressure drop the load increases on
the fan to dissipate the heat load generated in the Cooling Tower with
ABS 2.5 Dia Nozzles reduces frequency of clogging.
the result motor get tripped off frequently.
Wide spray angle.
Easy lock installation and Nozzles removal need no tools.
Fills placement is uniform due to the square shaped of Cooling
F Fills placement is not uniform due to round shaped. To place the fills
Towers.
on round shaped is uneven and to fill the gap the fills segments are cut
and placed with the result its likely that air pockets develop and as a
result Tower efficiency is reduced.
Maintenance is easy due to easy access through window and can Maintenance is difficult due to fixed system of all components. No
be carried out even when the Tower is in operation.
window is provided. Maintenance job cannot be carried out while the
Tower is in operation.
To maintain Square shaped Cooling Tower any of your maintenance You need to call trained personnel from the supplier of Cooling Tower.
personnel can carry out the maintenance job.

19

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

We are supplying to process industries like


01.

HVAC

14.

Air Compressions.

02.

Steel Plant.

15.

Oxygen Plants.

03.

Chemical & Fertilizer industries

16.

Breweries & Distilleries.

04.

Cement Industries.

17.

Forgings Industries.

05.

Pharmaceutical Industries

18.

Paper Industries.

06.

Machine Building Industries.

19.

Textile Industries.

07.

Petroleum Industries

20.

Food Processing Industries.

08.

Air Condition & Refrigeration Plant.

21.

Sugar Industries.

09.

Plastic & Rubber Industries.

22.

Anodizing

23.

D.G. Sets

24.

Power Plants.

10.

Automobile Industries.

11.

Induction Furnaces.

12.

Process Plants.

13.

Glass Industry.

20

Plus many more process industries


where hot water is need to be cool for
process

Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Contact Information

National Cooling Towers


Contact Person: Vishwesh Rajguru
Office:24 & 26,Amrapali Industrial Estate, Ram Mandir Road, Goregaon (W),Mumbai-400104, Mumbai,
MH,INDIA

Works: 148/2,GIDC,Umbergam,Gujarat, INDIA


Office Telephones: +91 22- 26765010 or 11 or 12 | Fax: +91-22-26765013
Cellular: +91 9833094837 and +91 7506657552
Emails: rajguru.nct@gmail.com or rajguru@nationalcoolingtower.com

National Cooling Towers

22
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com

or

Phone : +91 9833094837

Potrebbero piacerti anche