Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
or
Company Information
Name of CEO : Mr. S. Chandrashekhar
Establishment Year : 1990
Business Type : Manufacturer & Merchant Exporter
No. of Employees : 100-150
Annual Sales : 8 to 10 Core INR.
Market Cover :
All over India and World Wide Markets mainly Africa and Middle
East
Member Of :
or
Capacity
a)
03 to 1000 TR
b)
25 TR and Above
c)
d)
01 TR To 50 TR
e)
03 TR TO 350 TR
f)
Oil Chillers
01 TR TO 50 TR
g)
5 KW Upwards
h)
50 TR to 500 TR
i)
50 TR to 80 TR
j)
i)
Above 50 TR
or
HVAC
02.
Steel Plant.
03.
04.
Cement Industries.
05.
Pharmaceutical Industries
06.
07.
Petroleum Industries
08.
09.
10.
Automobile Industries.
11.
Induction Furnaces.
12.
Process Plants.
13.
Glass Industry.
14.
Air Compressions.
15.
Oxygen Plants.
16.
17.
Forgings Industries.
18.
Paper Industries.
19.
Textile Industries.
20.
21.
Sugar Industries.
22.
Anodizing
23.
D.G. Sets
24.
Power Plants
or
Incepted in the year 1990, we at National Cooling Towers (ISO 9001:2008 certified company), have
become one of the recognized firm engaged in designing manufacturing and erection of an exclusive
range of reliable, tailor-made Water Cooling Towers (FRP Induced Draft Counter Flow, Timber
Induced Draft Cross and Counter Flow, RCC Induced Draft Cross and Counter Flow )
plus Air Blast Coolers and Air and Water Chilling Plants.
Owing to our state-of-the-art manufacturing unit comprising latest machinery, we are able to fabricate
high quality Cooling Towers & Air Blast Coolers and Chilling Plants as per CIT-USA,CE and
ISO 9001:2008 standards. We undertake site supervision, erection, testing & commissioning. Our
experience and qualified sales and service staff work in partnership with you to provide technical advice
and field service support.
National Cooling Towers pays great attention to detail, using only high quality materials and
submitting the produced machines and equipments to numerous checks and inspections. In this way, we
are succeeding in combining reliability, high technology and simplicity of use with Zero maintenance.
We have a symbolic presence across the globe in the industry as our supplies of Cooling Towers have
touched more than 60000 and Chilling Plants more than 5000. Products deployed across the India
and globe in high-profile customers.
5
or
Approved by
6
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com
or
7
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com
or
Email: rajguru.nct@gmail.com
or
Email: rajguru.nct@gmail.com
or
10
Email: rajguru.nct@gmail.com
or
Approved by
National Cooling Tower make Air and Water Chillers Detail View
11
or
or
or
14
or
15
or
Why Counter Flow is always better than Cross Flow. Page 1 based on Practical ( Important
points to be consider before buying)
A) National Induced Draft Counter Flow Cooling
Tower:In the Induced Draft Counter Flow, always the dry
air is in contact with the cool water emerging out from
the PVC fills. That means when the air passes
through the PVC fills the proper water to air contact
occurs and the water evaporate. Thus it loses it heat
energy and the moist air is thrown out which will not
be re-circulating because the total height of the
cooling tower is maintained for the fresh air to flow
from the bottom.
16
or
Why Counter Flow is always better than Cross Flow. Page 2 based on Practical ( Important)
There are no louvers in NATIONAL Cooling Towers.
Cross flow cooling towers have water distribution on top & header
type which is exposed to sun. Due to this, chances of algae
formation are increased. Also because of the exposed water
distribution, dust tends to settle on the top and is circulated with
cooling water. The dust and algae tend to depositing in air
condenser chiller and compressor jackets, affecting heat transfer
whereby discharge pressure will be more effects the performance
of the air-conditioning plants.
The removal of packs in cross flow cooling tower is very
cumbersome & time consuming.
17
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com
or
Comparative Evaluation Study between FRP Induced Draught Counter Flow Cooling
Tower and Natural Draught Fan Motor Less Cooling Tower ( Important)
Sr. No
1
2
3
4
5
6
18
Dissipation of latent heat load guaranteed Can not guarantee dissipation of latent heat load. The dissipation
during any climatic conditions.
depend upon wet and dry bulb temperature.
Desired temperature dropped
The temperature dropped is not constant and temperature dropped
guaranteed.
can not be achieved.
Evaporation and drift losses are
Evaporation and drift losses percentage average around 2.00% to
maximum 0.80% to 1.00% on your
2.50% on circulation of water flow rate or even more depending
circulation of flow rate.
upon atmospheric seasonal wet and dry bulb temperature and due
to wind velocity and height of Cooling Tower.
Less area required and limited height.
Required more area and higher height.
Due to limited height the pump head is
also required less in capacity.
Energy saving due to limited height,
single header with 1/2 dia Spray Nozzles
minimum quantity of Nozzles required.
Foreign particles accumulated is
negligible due to enclose body of Cooling
Tower.
or
COMPARATIVE STUDY BETWEEN Square Shaped and Bottle or Round Shape Cooling Towers
SQUARE SHAPED
National design Cooling Tower is ONE peace mould construction.
Square shaped the uniform thickness are maintained. We provide
Pyramid type dome.
Fix header water distribution system has uniform water distribution
without loosing the pressure dropped due to fixed header system.
No tension bar and no Ball Bearing are required.
Fix header water distribution system with water inlet on the top and
outlet in the basin is easy to maintain within limited time.
19
or
HVAC
14.
Air Compressions.
02.
Steel Plant.
15.
Oxygen Plants.
03.
16.
04.
Cement Industries.
17.
Forgings Industries.
05.
Pharmaceutical Industries
18.
Paper Industries.
06.
19.
Textile Industries.
07.
Petroleum Industries
20.
08.
21.
Sugar Industries.
09.
22.
Anodizing
23.
D.G. Sets
24.
Power Plants.
10.
Automobile Industries.
11.
Induction Furnaces.
12.
Process Plants.
13.
Glass Industry.
20
or
Contact Information
22
Emails: rajguru.nct@gmail.com and rajguru@nationalcoolingtower.com
or