DESCRIPTION / IDENTIFICATION
The MM series proportional control valves use Proportion-Air's
closed loop technology to deliver pressure control which is linear
and proportional to an electrical command signal.
The MM1 uses two solenoid valves to control system pressure.
One valve functions as an inlet control, the other as an exhaust
control. A pressure sensor measures system pressure and
provides a feedback signal to the electronic controls which is
compared to the command signal. Difference between the two
signals causes the valves to open or close allowing pressure in or
out of the system.
The MM2 is similar to the MM1 but uses a double loop control
scheme. In addition to the internal pressure transducer, the MM2
also receives a feedback signal (0-10 VDC standard) from an
external sensing device. The external signal functions as the
primary feedback and is compared to the command signal. Since
the secondary feedback is a transduced signal, many types of
transducers may be used as feedback such as pressure, force,
position, flow, etc.
SPECIFICATIONS
ELECTRICAL
SUPPLY VOLTAGE 15-24 VDC
SUPPLY CURRENT 250 mA
TABLE 1
RATED PRESSURE FOR MM VALVES
INSTALLATION
ELASTOMERS Fluorocarbon
MANIFOLD Brass
VALVES Nickel Plated Brass
PRESSURE TRANSDUCER Silicon, Aluminum
PHYSICAL
OPERATING TEMERPATURE 32-158F (0-70C)
WEIGHT 0.7 lb. (0.3 Kg)
PANEL MOUNT
ELECTRICAL CONNECTIONS
1.
2.
3.
4.
FUNCTION
GND DC COMMON
P+ DC POWER
MANIFOLD MOUNTED
1.
2.
3.
4.
C+ COMMAND +
C- COMMAND M MONITOR
L2 2ND LOOP IN
INPUT SIGNAL: E, K, V
All voltage command MMs use common mode voltage, meaning the
DC Common pin is the common reference for both power and
command.
GND
P+
C+
C-
L2
DC COMMON DC POWER
0-10 VDC
(POWER AND
COMMAND +
COMMAND)
INPUT SIGNAL: I
All current command MMs use a differential current loop scheme,
meaning current flow is from C+ to C on the MM valves.
GND
PNEUMATIC CONNECTIONS
1.
2.
3.
4.
P+
C+
C-
L2
DC COMMON DC POWER
4-20mA
4-20mA
(POWER AND
COMMAND + COMMAND COMMAND)
MONITOR SIGNAL: E, K, V
Use the following wiring diagram for MM units with voltage monitor
feedback.
MONITOR SIGNAL: C, S
Use the following wiring diagram for MM units with current monitor
feedback.
All MM2 valves are designed to accept a 0-10VDC second loop input
signal. Wire the external feedback signal to pin L2 on the electrical
connector.
CURRENT SOURCING
CURRENT SINKING
Inlet Valve
RE-CALIBRATION PROCEDURE
All MM valves come pre-calibrated from the factory using precision
calibration equipment. If the MM valve needs re-calibration, use
the procedure described below:
DIN RAIL
Exhaust Valve
MM1 VALVES
1.
Inlet Valve
MANIFOLD MOUNT
14.7
150 PS
10 11 12 Options
3D
TF
Section >
1
Type
Zero Offset
Single Loop
Mounting Type
D
Manifold Material
Brass (Typical)
Aluminum
Thread Type
N
NPT
BSPP
11 Pressure Unit
0 to 10 Vdc
4 to 20 mADC
0 to 5 Vdc
1 to 5 Vdc
PS
PSI
MB
No Monitor
0 to 10 Vdc
0 to 5 Vdc*
1 to 5 Vdc*
4 to 20 mADC (Sinking)
4 to 20 mADC (Sourcing)
Millibars
BR
Bar
KP
Kilopascal
MP
Megapascal
MH
mm Hg
Inches Hg
IH
Inches H2O
IW
mm H2O
Kilograms/cm
Torr*
Centimeters H2O
MW
KG
TR
CW
12
Absolute Pressure
Gage Pressure
Recommended Accessories
H14612
DRMKT-01
Power Connector
DIN Rail Mounting Kit
Safety Precautions
Please read all of the following Safety Precautions before installing or operating any Proportion-Air, Inc. equipment or
accessories. To confirm safety, be sure to observe ISO 4414: Pneumatic Fluid Power - General rules relating to systems
and other safety practices.
Warning
Improper operation could result in serious injury to persons or loss
of life!
1. PRODUCT COMPATIBILITY
Proportion-Air, Inc. products and accessories are for use in
industrial pneumatic applications with compressed air media.
The compatibility of the equipment is the responsibility of the
end user. Product performance and safety are the
responsibility of the person who determined the compatibility
of the system. Also, this person is responsible for continuously
reviewing the suitability of the products specified for the
system, referencing the latest catalog, installation manual,
Safety Precautions and all materials related to the product.
2. EMERGENCY SHUTOFF
Proportion-Air, Inc. products cannot be used as an emergency
shutoff. A redundant safety system should be installed in the
system to prevent serious injury or loss of life.
3. EXPLOSIVE ATMOSPHERES
Products and equipment should not be used where harmful,
corrosive or explosive materials or gases are present. Unless
certified, Proportion-Air, Inc. products cannot be used with
flammable gases or in hazardous environments.
4. AIR QUALITY
Clean, dry air is not required for Proportion-Air, Inc. products.
However, a 40 micron particulate filter is recommended to
prevent solid contamination from entering the product.
5. TEMPERATURE
Products should be used with a media and ambient
environment inside of the specified temperature range of 32F
to 158F. Consult factory for expanded temperature ranges.
6. OPERATION
Only trained and certified personnel should operate electronic
and pneumatic machinery and equipment. Electronics and
pneumatics are very dangerous when handled incorrectly. All
industry standard safety guidelines should be observed.
7. SERVICE AND MAINTENANCE
Service and maintenance of machinery and equipment should
only be handled by trained and experienced operators.
Inspection should only be performed after safety has been
confirmed. Ensure all supply pressure has been exhausted and
residual energy (compressed gas, springs, gravity, etc.) has
been released in the entire system prior to removing
equipment for service or maintenance.
PROPORTION-AIR, INC.
8250 N. 600 West, P.O. Box 218
McCordsville, Indiana 46055
317.335.2602 | info@proportionair.com
5
Caution
Improper operation could result in serious injury to persons or
damages to equipment!
1. PNEUMATIC CONNECTION
All pipes, pneumatic hose and tubing should be free of all
contamination, debris and chips prior to installation. Flush
pipes with compressed air to remove any loose particles.
2. THREAD SEALANT
To prevent product contamination, thread tape is not
recommended. Instead, a non-migrating thread sealant is
recommended for installation. Apply sealant a couple threads
from the end of the pipe thread to prevent contamination.
3. ELECTRICAL CONNECTION
To prevent electronic damage, all electrical specifications
should be reviewed and all electrical connections should be
verified prior to operation.
2.
3.
4.
Warranty
Proportion-Air, Inc. products are warranted to the original
purchaser only against defects in material or workmanship for one
(1) year from the date of manufacture. The extent of ProportionAirs liability under this warranty is limited to repair or
replacement of the defective unit at Proportion-Airs option.
Proportion-Air shall have no liability under this warranty where
improper installation or filtration occurred.