Sei sulla pagina 1di 10

Pontificia Universidad Catlica del Per

Facultad de Ciencia e Ingeniera


Seccin de Ingeniera de Minas

INFORME DE LABORATORIO N8
CURSO

Concentracin de Minerales

TEMA

Hidrociclones Determinacin del D50

JEFES DE PRACTICA

:
Manuel Shishido
Jackeline Chan

ALUMNO

Erick Armas Baldeon

CODIGO

20101167

SEMESTRE ACADEMICO:

2015-1

1. Objetivo de la practica

Determinar el dimetro cincuenta de dos muestras de mineral usando


hidrociclones, reforzando el concepto de carga circulante.

2. Abstract

In this laboratory we knew the use of the hidrociclone and we had to


calculate the D50. The experiment was made for a magnetite mineral.

First, we prepared 200 gr or less of mineral by Denver quarter to send


it to a granulometric test(this is for food data), then we had to prepare
a pulp with 1 kg of the mineral, then we passed them by the
hydrocyclone to obtain the undersize and oversize sample. Later we
pass the oversize by the filter to eliminate the excess of water in that
pulp, we dry it and weigh, and finally we make a granulometric test
with the series 2 of sieves. We make the same thing for the undersize
but using the series 3 of sieves.

Finally, we weigh every mesh, with this process we recovered the


necessary data of the undersize and oversize and we found the D50.

3. Metodologia de la practica

Para este experimento trabajaremos con mineral de magnetita,


adems aplicaremos el stocks y utilizaremos un ciclon D3( dimetro
de 3 pulgadas) para un plato de 20 a 30 TM.
Primero tenemos dos kilos de muestra de mineral, la cual la dividimos
en 2 partes mediante el mtodo de rifles Denver.

Figura1: hidrociclon tipo creps(ms


eficiente que el hidrociclon cnico)

Luego con la primera muestra trataremos de lograr un peso menor a


200 gr para hacer un anlisis granulomtrico del alimento. Empiezo
desde malla 20 y a continuacin hago mi serie de tamices.

Figura 2: serie de tamices de Tyler para el


anlisis granulomtrico del alimento.

Con la otra parte del mineral de


magnetita que es 1012.9 g formamos una pulpa agregndole agua a
la muestra y con esta pulpa procedemos a alimentar el hidrociclon
dndonos el overflow y el underflow para luego secar cada una de las

muestras. Ya que el overflow es la que ms agua tiene pondremos


ms nfasis en este en el filtro a presin.

Figura 3: la muestra del overflow se pasa por


el filtro a presin

Luego de este procedimiento se tiene la muestra del overflow filtrada.

Figura 4: Muestra de overflow luego de


pasar por el filtro a presin.

Despus de esto mandamos la muestra al horno por espacio de 1


hora para poder tener un mnimo de humedad y pueda ser bien
tamizado en el rotap.

Ahora haremos el mismo procedimiento para el underflow.

Figura 5: Se echa la muestra


Figura 6: muestra de underflow filtrada
de underflow al filtro a presin.

Luego se lleva cada muestra filtrada al horno por espacio de una hora
y se saca del horno para pesarlo y hacer un anlisis granulomtrico.

Figura 7: muestra de overflow


despus de pasar de sacarlo del
horno.

Figura8: muestra del underflow


despus de sacarlo del horno.

Se puede observar en la imagen


anterior que aun la muestra
contiene humedad relativamente alta para pasarlo por los tamices
pero como no hay tiempo seguimos asi.
Luego de sacar del horno cada una de las muestras lo llevamos a la
serie de tamices para hacer un anlisis granulomtrico del underflow
y del overflow, despus pesamos cada tamiz para finalmente calcular
el D50.

Figura9: muestra del overflow


despus de pesar cada malla y
separarla.

4. Resultados:
Teniendo los pesos de la alimentacin, del underflow y del overflow:
W
W
alimentacion( underflow(gr W overflow(gr)
gr)
)
1.7
1.7
1.3
11.1
10.4
10
24
25.8
24.6
25.8
29
27.2
26.6
26.8
27.4
32.7
36.1
35.8
28
21.7
26.7
29.5
32.3
34.3
179.4
183.8
187.3
Se procede a elaborar una tabla para hallar los porcentajes
acumulados:
Malla
Tyler

Abertur
a

M30
M40
M50
M70
M100
M140
M200
M-200

m
600
425
300
212
150
106
5

Walimentacion
(A)
%
Parcial % Acum.
0.95%
0.95%
6.19%
7.13%
13.38%
20.51%
14.38%
34.89%
14.83%
49.72%
18.23%
67.95%
15.61%
83.56%
16.44%
100.00%

W underflow (D)
%
Parcial % Acum.
0.92%
0.92%
5.66%
6.58%
14.04%
20.62%
15.78%
36.40%
14.58%
50.98%
19.64%
70.62%
11.81%
82.43%
17.57%
100.00%

W overflow (R)
%
Parcial % Acum.
0.69%
0.69%
5.34%
6.03%
13.13%
19.17%
14.52%
33.69%
14.63%
48.32%
19.11%
67.43%
14.26%
81.69%
18.31%
100.00%

Ahora que ya tengo mi carga circulante elaborar otra tabla para hallar
la carga promedio del overflow y del underflow:

Malla
30-40
40-50
50-80
80-100
100-120
120-200

Abertura
Promedio
um
512.50
362.50
240.00
165.00
137.50
100.00

Tonelaje
Tonelaje Overflow
Underflow
% Parcial TMD
% Parcial TMD
1.92
11.520
16.6
144.759
4.92
29.520
21.61
188.448
15.39
92.340
33.68
293.703
4.85
29.100
5.06
44.125
17.12
102.720
8.35
72.815
54.25
325.500
10.26
89.471

Cp
Overflo
w

Cp
Underfl
w

0.074
0.135
0.239
0.397
0.585
0.784

0.926
0.865
0.761
0.603
0.415
0.216

Con estos datos ya puedo calcular el D50 asi:

Abertura
Promedio(u
m)
600
425
300
212
150
106

Cp Overflow
0.074
0.135
0.239
0.397
0.585
0.784

Cp
Underflow
0.926
0.865
0.761
0.603
0.415
0.216

Y elaboro mi curva de Tromp:

Curva de Tromp

Overflow
Underflow

En este grafico se puedo observar que el punto que intersecta la


grfica del overflow y underflow es mi D50:

D50= 150um

5. Discusin de resultados

El resultado obtenido y los datos fueron obtenidos del


laboratorio anterior, ya que los datos que mi grupo obtuvo
fueron errneos y tambin la grfica de tromp nunca se cruzaba
para hallar el d50, as tuve que calcular el D50 con los datos de
mis compaeros del anterior laboratorio.
El error en este caso es aceptable, ya que la prdida de
material no es muy significante.
En el rebose del hidrocicln para el concentrado podemos
apreciar que casi la mitad de la muestra analizada se queda en
el recipiente, es decir presenta un tamao menor a la ltima
malla de la serie, en este caso la malla 200.
Para el caso de las arenas del hidrocicln, en el concentrado
ms de la mitad queda en el recipiente y en el caso de la arena
aproximadamente el 77% queda en el recipiente, la
granulometra del fino obtenido es muy fina para la serie.
Es notoria la presencia de error en los valores analizados, en la
grfica de la determinacin del D50 para el concentrado y los
valores de D50 estn aproximadamente redondeados entre 150
160 micrones.

6. Conclusiones

Se puede concluir que los hidrociclones son equipos utilizados


para separar o clasificar una muestra obtenida de la mezcla de
un slido y un lquido (mezcla bifsica).
Las variables o parmetros que intervienen en el hidrocicln son
los siguientes:
La pulpa y su granulometra.
La velocidad de la pulpa al ingresar.
La presin.
Los parmetros mencionados anteriormente tienen mucha
influencia en la eficiencia de la separacin o clasificacin de la
muestra en overflow y underflow cuando se trabaja a escala
real.

Al verter la pulpa esta debe estar homogenizada para la mejor


clasificacin.
Como en todos los procesos de anlisis del mineral, la muestra
debe ser lo ms representativa posible.

Potrebbero piacerti anche