Sei sulla pagina 1di 2

V1.

Menu List

Reader Appearance

Press [M] key to enter system management menu.

40mm

80mm

Other Setup

(This requires the administrator authorization if there is admin

14:03

10-29-09

IN

14:03

09

09

10-29-09

THU

registered in the system.) Menu List:

IN

Restart
Button

THU

Dev ID

Enroll

Language

Mode

Workcode Scope

Delete

IP Address

Daylight Saving

Verify Mode

User

Net

Group Setup

Anti-Back

Admin Setup
Fingerprint Access control Card Access control
Front View
Front View

Server Port

Setup

Door Bell Key

0-9

System Info

Confirm Key
Confirm Present Operation

Keypad, LCD, Sensor, Flash

09 : 00
10-11-17

[M]

26
WED

PW+FP
RF+PW

MENU
User
Setup
USB Flash

[OK]

User
Enroll
Delete
Verify Mode

[OK]

Select [Enroll]

Select [User]

008101
Set-OK

G00

The user in Group00 can not open the door

G01

The user in Group01 can open the door anytime

Factory default
setting

Input user ID

Enroll FP

Enroll FP

[OK]

Enroll FP

Take Off!

Place Finger #1

Place Finger #2

Take Off!

008101-1

Enroll fingerprint

Sav-OK

Press [OK] to save

Enroll Password: Password length: 000000-999999.


press [OK]

Enroll
FP
1/2
Password /Card
Esc-C
Set-OK

Enroll PWD

[OK]

Esc-C

Select [Password]

Enroll
FP
1/2
Password/ Card
Esc-C
Set-OK

[OK]

Enroll Card

[OK]

Select [Card]

Enroll PWD
******
Set-OK

Input password

Enroll Card
press [OK]

PWDID

******

Confm

******

[OK]

Select [User]

User
Group Setup
Admin Setup
Admin Clear

Input password again

008101-C
Cancel-C
Sav-OK

Swipe the card

Press [OK] to save

Selelct [Admin Setup]

TCP/IP Server mode: Common network mode


TCP/IP Client mode: Only communicate
with the PC which has static IP

Factory default
setting

Related Language

Server Mode

Set terminal IP address when communication


of TCP/IP, IP address must be a static
192.168.0.218
IP address.

IP Address
Subnet Mask

Subnet Mask of the LAN

MAC Address

Unique Physical address of the network moudle. This


setting can not be modified.

Gateway IP
Server IP
Server Port

255.255.255.0

Default Gateway of the LAN

192.168.0.1

The IP address of the Sever Machine


when using Client Mode TCP/IP
communication.

192.168.0.7

Its the Software Port number used when the


read is configured for TCP/IP communication.

5010

Unlock: M [Setup][OK][System][OK][Unlock][OK]No/1~15[OK]
[C][OK]. No-no delay time; The maximum delay time is 15 seconds.

Explanation

1-15
No
Factory default
setting

The duration of the audible alarm to notify employees


of events. (Lunch, break, Off Duty)
The device does not generate a door open signal after
successful verification.
5

Door Alert: M [Setup][OK][System][OK][Door Alert][OK]


to select No/1~99[OK][C][OK]. No-no alert signal.

Explanation

Item
1-250
No
Factory default
setting

It generates the door open alarm signal if the door open


time is longer than the preset value
Disable the door open alarm
15

Illustration for placing fingerprint

Press [OK] to save

Enroll Card
Card
Enroll

Swipe card!

Admin Setup

Admin Setup

Optional 4 languages.

008101-P
Cancel-C
Sav-OK

two administrators to each unit.


[OK]

Languages

Factory default
setting

Explanation

Item

Enroll PWD

PWDID

Admin Setup: Admin(Administrator) has full access permissions to the device. It is recommended to assign a minimum of
MENU
User
Setup
USB Flash

Explanation

Item

Enroll FP

Cancel-C

Select [FP]

Device ID of the unit which is required in software


communication
1

Use [ /IN]/[OUT/ ] to select ENG/FRCH/GERM/...[OK][C][OK].

Enroll FP

/MAC Address/Gateway IP/Server IP/Server Port][OK]Modify parameters[C][OK].

Item

Explanation

Language: M[Setup][OK][System][OK][Language][OK]

Enroll FP
Enroll
FP
1/2
Password/Card
Esc-C
Set-OK

G01

Tips: It doesnt allow duplicate Device ID in one LAN. Otherwise, it will cause software
communication error.

Enroll Fingerprint: Place the same finger on the sensor twice in a row to enroll fingerprints.
press [OK]

It is according to the Group & Time zone setting which


can be set through the software

M[Setup][OK][System][OK][Dev ID][OK]
Input the devices ID[OK][C][OK].

1-99999999

(ID000001-999999

Net: M [Setup][OK][System][OK][Net][OK]to select [Mode/IP Address/Subnet Mask

Mode

Explanation

Factory default
setting

ID
Esc-C

Any

Item

Enroll

Enter the user ID first then verify the fingerprint

Tips: WorkCode indicates the work typeeasily distinguishes which attendance record
is related to which work type.

Group Setup: M[User][OK][Group Setup][OK][OK]

Dev ID:

Enroll User: Each user can register two fingerprints, one password and one RFID card.
IN

Max 999999
Min
0

Tips: Group setup is used for managing the access control privileges. Each group can
contain 4 time zones.

User, FP, Log, Serial,FirmVer

Operation Guide
1

Factory default
setting

It requires both Card and Fingerprint


verification together
It requires both Password and Fingerprint verification
together
It requires both Card and Password verification
together

G02-16

Re-Verify

Hardware Test

State Key(Clock Out)/Down

Num. Keys
Enter Employee ID or Password

Log Alert

Log Setup

State Key(Clock In)/Up

Valid scope for the Workcode

Item

Image Disp.

Workcode Setup Key

0-999999

Input employee ID[OK]Input the group ID[OK][OK].

Auto Update

Cancel/Power Key
Exit/Cancel the Present Operation
Power on/Power off

Fingerprint only, Card only or ID+Password only

Door Alert

Auto Off

Menu Key
Enter System Management Menu

Any

Factory default
setting

Unlock

System

Explanation

Gateway IP
Server IP

Input Max[OK]Input Min[OK] [C][OK].

Item

ID+FP

Volume

WorkCode: M [Setup][OK][System][OK][WorkCode Scope][OK]

Explanation

MAC Address

Precision

Admin Clear

Side View

Subnet Mask

M[User][OK][Verify Mode][OK][OK]Input employee ID[OK]


Use [ /IN]/[OUT/ ] to select ANY/RF+FP/PW+FP/RF+PW/ID+FP[OK][OK].

Item

RF+FP

Time
180mm

Verify Mode:

[OK]

[OK]
Esc-C

ID

Admin Setup
000000

Add-OK

[OK]

008101
No-C

Input Admin ID

[OK]
Yes-OK

Admin Setup
ID
008101
Esc-C

Add-OK

Setup successful

Place finger straight and


flat on the sensor. Insure
maximum sensor coverage.
Place finger in the center of the sensor.

Place finger on the sensor surface

V1.4

Access Control Reader & Access Control Power Supply

Package List
1 Reader
THU

Access control

C H ...

COMPACT

CD-ROM

windows

Windows 98
Windows 2000
Windows XP
Windows Vista
Windows 7

d
ar
C

Access Control Power Supply

GND PUSH NO

FOR
EN

D/S GND

or

IN
09

12I

14:03

10-29-09

COM NO GND D/M

THU

Power on to unlock

Door Sensor

NC

NC

Installation Step

GND

Installation Diagram

Exit Button

WO0 WO1 GND R4A R4B GND DB2 DB1

IN
09

Connector Jack

Accessory Package

+12

14:03

10-29-09

2 Instruction Package

Door Bell

Power off to unlock

1 Drill holes in the wall follow the hole position on back panel
2 Install and fix back panel, connect related cables
3 Connect back panel to front panel by flat cable
3

Access Control Reader & Switching Power Supply

4 Attach access control reader

Wiring Instruction

Switch Power Supply

Wiegand 0 Output

WO1

Wiegand 1 Output

GND

GND

R4A

RS485A

R4B

RS485B

GND

GND

DB2

Door Bell 2

DB1

Door Bell 1

12I
D/S GND

Description

WO0

COM NO GND D/M

Mark

Power on to unlock

Door Sensor

NC

PIN

Exit Button

WO0 WO1 GND R4A R4B GND DB2 DB1

WO0 WO1 GND R4A R4B GND DB2 DB1

TCP/IP
Communication Port

+12V GND

P1

Door Bell

Power off to unlock

Access Control Reader & SC011

NO

NO

COM

COM

NC

NC

Switch Power Supply

12I

GND

I II III
RELAY DELAY
12V-I
GND
GND
NC
NO
COM

D/S GND

GND

NC

ON OFF
PROGRAM

PROGRAM MODE - (YELLOW)


NORMAL MODE - (BLUE)

12V-O
GND
D0
D1
GND
BUT

Important notice: Please follow the wiring diagram as it is displayed. Damaged products due to
improper wiring are not covered by product warranty.

Power on to unlock

NC

Power off to unlock

WO0 WO1 GND R4A R4B GND DB2 DB1

Door Monitor

RELAY OUT

Door Switch

D/M

POWER
SUPPLY LOCK

D/S

+12V GND

Connection Cable
Connect the front part of device

COM NO GND D/M

GND

ANVIZ DEVICE

DC 12V Input

12I

12I
GND

D/S GND

Description

GND D/M

Mark

COM NO

PIN

EXIT
BUTTON

P2

Exit Button

The products are subject to change without notice.

Potrebbero piacerti anche