Introduction
1.0
8
Fastening Technology
2.0
Anchoring Systems
3.0
14
Reference
4.0
372
Hilti North America Product Technical Guide Volumes 1 and 3 are also available.
Contact your Hilti Field Engineer about them today.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 1
Table of contents
Section Description
Page
1.0
1.1
1.2
1.3
1.4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
About published load values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Our purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Our quality system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.0
Fastening Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1
Base materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1.1
Base materials for fastening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1.2
Concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.1.3
Masonry materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1.4
Autoclave aerated concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1.5
Pre-tensioned/Pre-stressed concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1.6
Bonded post-tensioned concrete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1.7 Admixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2
Evaluation of test data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.3
Corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.1
The corrosion process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.2
Types of corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.3
Corrosion protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.4
Test methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.3.5
Hilti fastening systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.3.6 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.0
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7
3.1.8
3.1.9
3.1.10
3.1.11
3.1.12
3.1.13
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Anchoring Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Anchor principles and design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Anchors in concrete and masonry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Anchor working principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Anchor behavior under load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Anchor design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Strength Design - SD (LRFD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Hilti simplified Strength Design tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Allowable Stress Design (ASD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Design examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Torquing and pretensioning of anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Design of anchors for fatigue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Design of anchors for fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Design of post-installed reinforcing bar connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Adhesive anchoring systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Adhesive anchoring systems overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
HIT Adhesive Anchor system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
HIT-HY 200 Adhesive Anchoring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
HIT-RE 500-SD Epoxy Adhesive Anchoring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
HIT-RE 500 Epoxy Adhesive Anchoring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
HIT-ICE Adhesive Anchoring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
HIT-HY 70 Adhesive System for Masonry Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
HVU Capsule Adhesive Anchoring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Technical information for the following Hilti Adhesive Anchoring Systems are available online.
HIT-HY 100 Adhesive Anchoring System
HIT-HY 150 MAX-SD Adhesive Anchoring System
HIT-HY 150 MAX Adhesive Anchoring System
HIT-HY 10 Plus Adhesive Anchoring System
HFX Adhesive Anchoring System
HTE 50 Transportation Epoxy
2 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Table of contents
Section Description
Page
3.3
Mechanical Anchoring Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
3.3.1
HDA Undercut Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
3.3.2
HSL-3 Heavy-duty Expansion Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
3.3.3
HSL-GR Stainless Steel Heavy Duty Expansion Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
3.3.4
HSL-I Internally Threaded Expansion Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
3.3.5
KWIK Bolt TZ Expansion Anchor (KB-TZ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
3.3.6
KWIK HUS-EZ (KH-EZ) Carbon Steel Screw Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
3.3.7
KWIK HUS-EZ I (KH-EZ I) Internally Threaded Screw Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
3.3.8
KWIK Bolt 3 (KB3) Expansion Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
3.3.9
KWIK HUS (KH) Screw Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
3.3.10
HCA Coil Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
3.3.11
HDI+, HDI-L+, HDI and HDI-L Drop-in Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
3.3.12
HDI-P Drop-in Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
3.3.13 HCI-WF/MD Cast-in Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
3.3.14
HLC Sleeve Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
3.3.15
KWIK-CON II+ Fastening System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
4.0
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
4.2
4.2.1
4.2.2
4.2.3
4.2.4
4.3
4.3.1
4.3.2
4.3.3
4.3.4
Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Approvals and Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
ICC-ES (International Code Council) Evaluation Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
COLA (City of Los Angeles) Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Miami-Dade County Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Underwriters Laboratories Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
FM Global Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Reference Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
ASTM Standards for Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
ASTM Plating Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
Federal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
ANSI Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
Technical References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Metric Conversions and Equivalents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Mechanical Properties of Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
Bolt Thread Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Concrete Reinforcing Bar Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
Technical information for the following Hilti Mechanical Anchors are available online.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 3
Fastening Technology
Installation*
LW
tgel
A: 7/45
min
w/HDB
R: 15/90
only
min
3.2.3
A: 7/45
min
R: 15/90
min
online
5 min/
30 min
HIT-RE 500-SD
Epoxy
3.2.4
30 min/
12 hrs
online
3.2.5
3.2.6
30 min/
12 hrs
8 min/
20 min
online
5 min/
45 min
online
5 min/
40 min
HTE 50
Transportation Epoxy online
20 min/
24 hrs
Overhead
Submerged
(underwater)
Water-filled
holes
Water-saturated
concrete
Diamond-cored holes4
4 min/
1.5 hrs
HFX Adhesive
4 min/
1 hrs
3.2.7
6 min/
30 min
3.2.8
HIT-HY 10+
Adhesive
Compatibility with
SafeSet Technology
Unreinforced
Multi-wythe brick
Hollow
clay brick
Hollow
concrete block
Grout-filled
concrete block
Hollow-core
concrete
Lightweight
concrete
Cracked
concrete3
Uncracked
concrete
Section number
tcure
Suitable. Technical data is available for this application. Refer to related sections within this technical guide.
May be suitable. Anchor system may function properly for this application. However, no substantiating data is available.
Indicates suitability for the stated condition alone. If multiple conditions apply simultaneously, see product specific details within this technical guide or
contact Hilti Technical Services.
1 Base material may vary widely. Site specific anchor testing may be required.
2 Unless otherwise stated, testing is performed in normal weight concrete. Lightweight concrete may be available. See product specific details within this technical
guide or consult the relevant building codes (ACI 318, IBC, etc.).
3 Refer to Section 2.1.2 for definition of cracked concrete.
4 Diamond coring is applicable where noted, however, it can be restricted to certain base materials, installation conditions and applications, certain Hilti tools,
or have associated load reduction. See product specific details within this technical guide.
4 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
7/8"
AC308
AC308
HIT-RE 500-SD
Epoxy
AC308
AC58
AC308
HIT-HY 70 Adhesive
AC58
AC60
HFX Adhesive
HTE 50
Transportation Epoxy
304/
316
3/8" 1-1/4"
7/8"
304/
316
3/8" 1-1/4"
3.2.4
7/8"
304/
316
3/8" 1-1/4"
7/8"
304/
316
3/8" 1-1/4"
7/8"
304/
316
3/8" 1-1/4"
304/
316
1/4"
304/
316
3/8" 1-1/4"
7/8"
304/
316
3/8" 1-1/4"
7/8"
304/
316
3/8" 1-1/4"
7/8"
3.2.3
3/4"
3/8"
HIT-HY 10+
Adhesive
316
HVU Capsule
3/8" 1-1/4"
304/
316
HIT-ICE Adhesive
Rebar
Size3
Stainless steel
Threaded rod
MIAMI-DADE
COLA
UL
FM
AC308
ICC-ES
Corrosion
Resistance2
Element Type
Seismic
Features*
NSF 61
Approvals
7/8"
3.2.5
3.2.6
3/4"
3.2.7
3.2.8
3/8"
3/4"
Suitable. Technical data is available for this application. Refer to related sections within this technical guide.
May be suitable. Anchor system may function properly for this application. However, no substantiating data is available.
Indicates suitability for the stated condition alone. If multiple conditions apply simultaneously, see product specific details within this technical guide or
contact Hilti Technical Services.
1 High cycle fatigue and shock/impact loading reference data is only available based on European testing and guidelines.
2 Refer to Section 2.3 for a more detailed discussion on corrosion and corrosion resistance.
3 Listed diameters are those with published load data. Larger diameter elements may be used with some adhesive anchor systems.
Contact Hilti for more information.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 5
Fastening Technology
Features
In-place (through)
fastening
Shock / impact
load4
3.3.4
KWIK Bolt TZ
Expansion Anchor
3.3.5
KWIK HUS-EZ
Screw Anchor
3.3.6
KWIK HUS-EZ I
Screw Anchor w/coupler
3.3.7
KWIK Bolt 3
Expansion Anchor
3.3.8
KWIK HUS
Screw Anchor
3.3.9
3.3.10
HDI+/HDI-L+/HDI/HDI-L
Drop-In Anchor
3.3.11
online
3.3.12
HCI-WF/MD Cast-In
Anchor
3.3.13
3.3.14
3.3.15
online
online
online
HLD KWIK-Tog
online
online
HSL-GR Heavy-duty
Expansion Anchor
3.3.3
HSL-I Internally
Threaded Exp. Anchor
Unreinforced
Multi-wythe brick
3.3.2
Hollow clay
brick
HSL-3 Heavy-duty
Expansion Anchor
Hollow concrete
block
Grout-filled
concrete block
Hollow-core
concrete
3.3.1
Concrete
over metal deck
Lightweight
concrete
Cracked
concrete3
Uncracked
concrete
Section number
Seismic
LW
Suitable. Technical data is available for this application. Refer to related sections within this technical guide.
May be suitable. Anchor system may function properly for this application. However, no substantiating data is available.
No diamond cored holes
1 Base material may vary widely. Site specific anchor testing may be required.
2 Unless otherwise stated, testing is performed in normal weight concrete. Lightweight concrete may be available. See product specific details within this technical
guide or consult the relevant building codes (ACI 318, IBC, etc.).
3 Refer to Section 2.1.2 for definition of cracked concrete.
4 High cycle fatigue and shock/impact loading reference data is only available based on European testing and guidelines.
6 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
3.3.4
3/8"
3/4"
3.3.5
1/4"
3/4"
3.3.6
1/4"
3/8"
3.3.7
1/4"
1"
3.3.8
HSL-I Internally
Threaded Exp. Anchor
AC193
KWIK Bolt 3
Expansion Anchor
316
304/
316
KWIK HUS-EZ I
Screw Anchor w/coupler
Stainless steel
3.3.3
AC193
AC106
M20
AC193
KWIK HUS-EZ
Screw Anchor
M20
M10
M10
3.3.2
316
M24
AC193
M8
AC193
Size2
3.3.1
KWIK Bolt TZ
Expansion Anchor
Electro / mechanically
zinc plated
Corrosion resistance1
Round / mushroom
Hex bolt
MIAMI-DADE
Head type
COLA
UL
FM
ICC-ES
Approvals
304/
316
KWIK HUS
Screw Anchor
3/8"
3/4"
3.3.9
1/4"
3/4"
3.3.10
3.3.11
HDI+/HDI-L+/HDI/HDI-L
Drop-In Anchor
303
1/4"
3/4"
303
1/4"
1/2"
3/8"
3/8"
3.3.12
1/4"
3/4"
3.3.13
1/4"
304
3/4"
3.3.14
3.3.15
3/16" 1/2"
HLD KWIK-Tog
#8
#10
Suitable. Technical data is available for this application. Refer to related sections within this technical guide.
May be suitable. Anchor system may function properly for this application. However, no substantiating data is available.
No diamond cored holes
1 Refer to Section 2.3 for a more detailed discussion on corrosion and corrosion resistance.
2 Listed diameters are those with published load data.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 7
1.0 Introduction
1.1 About published load values
The Anchor Fastening Technical Guide is intended to
supplement the Hilti Product and Services Catalog with
1.2 Units
Enthusiastic customers
We create success for our customers by identifying their
needs and providing innovative and value-added solutions.
Build a better future
We embrace our responsibility towards society
and environment.
8 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
2.1.2 Concrete
Aggregate grading
specification
Concrete unit
weight pcf
Normal-weight
ASTM C33
145-155
Sand-lightweight
ASTM C330
105-115
All-lightweight
ASTM C330
85-110
Lightweight
insulating concrete
ASTM C332
15-90
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 9
Fastening Technology
Nominal
Minimum face-shell
Minimum web
thickness1
thickness1
in. (mm)
in. (mm)
in. (mm)
3/4 (19)
3/4 (19)
6 (152)
1 (25)
1 (25)
8 (203)
1-1/4 (32)
1 (25)
10 (254)
1-3/8 (35)
1-1/8 (29)
width of unit
1-1/4 (32)2
12 (305)
1-1/2 (38)
1-1/4 (32)
1-1/8 (29)
8"
7-5/8"
7-5/8"
8"
16"
Nominal size
(usually fictitious)
15-5/8"
Modular size
(actual)
10 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
2.1.3.4 Mortar
Mortar
Cement-lime
Masonry cement
Type
Average compressive
strength at 28 days,
minimum psi (MPa)
2500
(17.2)
1800
(12.4)
750
(5.2)
350
(2.4)
2500
(17.2)
1800
(12.4)
750
(5.2)
350
(2.4)
2.1.3.5 Grout
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 11
Fastening Technology
Average
compressive
strength, psi (N/mm2)
Density
lb/ft3 (g/cm3)
AAC - 2
360 (2.5)
32 (0.5)
AAC - 4
725 (5.0)
38 (0.6)
AAC - 6
1090 (7.5)
44 (0.7)
2.1.5 Pre-tensioned /
Pre-stressed concrete
2.1.7 Admixtures
the fastening.
Fastening Technology
F =
cv =
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 13
Fastening Technology
2.3 Corrosion
2.3.1 The Corrosion process
Corrosion by direct chemical attack occurs when the base material is soluble in the
corroding medium. One method of mitigating these effects is to select a fastener
that is not susceptible to attack by the corroding chemical. Compatibility tables of
various chemical compounds with Hilti adhesive and epoxy fastening systems are
provided in this technical guide.
When selection of a base metal compatible with the corroding medium is not
possible or economical, another solution is to provide a coating that is resistant to
the corroding medium. This might include metallic coatings such as zinc or organic
coatings such as epoxies or fluorocarbons.
2.3.2.2 Electrochemical
contact corrosion
All metals have an electrical potential relative to each other and are classified
accordingly in the galvanic series of metals and alloys. When metals of different
potential come into contact in the presence of an electrolyte (moisture), the metal
with more negative potential becomes the anode and corrodes, while the other
becomes the cathode and is galvanically protected.
The severity and rate of attack are influenced by:
a. Relative position of the contacting metals in the galvanic series
b. Relative surface areas of the contacting materials
c. Conductivity of the electrolyte
The effects of electro-chemical contact corrosion may be mitigated by:
a. Using similar metals close together in the electromotive force series,
b. Separating dissimilar metals with gaskets, plastic washers or paint with low
electrical conductivity. Materials typically used in these applications include:
2. Polytetrafluoroethylene (PTFE)
3. Polycarbonates
4. Neoprene/chloroprene
Note: Specifiers must ensure that these materials are compatible with other
anchorage components in the service environment.
c. Selecting materials so that the fastener is the cathode, the most noble or
protected component
d. Providing drainage or weep holes to prevent entrapment of the electrolyte
14 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
Corrosion 2.3
2.3.2.3 Hydrogen assisted
stress corrosion
cracking
Atmosphere
Industrial
5.6 m/year
Urban non-industrial
or marine
Suburban
1.5 m/year
Rural
0.8 m/year
Considerably less
than 0.5 m/year
Indoors
1.3 m/year
If covered sufficiently by
noncorrosive concrete
Mechanically deposited
zinc coating 40 107 m
Near saltwater
Exterior corrosive environments
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 15
Fastening Technology
2.3 Corrosion
2.3.4 Test methods
2.3.6 Applications
Hilti Super HAS threaded rods in 7/8" diameter size and KWIK
Bolt 3 mechanical anchors are zinc coated by the hot-dip
These application charts are offered as general guidelines.4 Site specific conditions may influence the decision.
Application
Conditions
Fastener recommendations
HDG or Sherardized
HDG or Sherardized
Stainless steel
Interior applications
Exterior applications
HDG or Sherardized
Non-safety critical
HDG, Sherardized
Safety critical
Stainless steel1
Non-safety critical
HDG or Sherardized
Safety critical
Stainless steel
16 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
Corrosion 2.3
2.3.6.2 Special applications
These application charts are offered as general guidelines.4 Site specific conditions may influence the decision.
Application
Conditions
Fastener recommendations
Stainless steel
Water treatment
Not submerged
Submerged
Stainless steel2
Not submerged
Submerged
Stainless steel 2
HDG, sherardized
Stainless steel1
Stainless steel
Non-safety critical
HDG, sherardized
Stainless steel1
Above grade
HDG
Below grade
Stainless steel
Non-safety critical
Stainless steel
Non-safety critical
Safety critical
Stainless steel1
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 17
Fastening Technology
18 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
between the anchor and the wall of the drilled hole during
setting of the anchor may also be supplemented by local
deformation of the concrete. The frictional force is proportional
to the magnitude of the expansion stresses generated by
the anchor. Torque-controlled expansion anchors like the
KWIK Bolt TZ and HSL-3 anchors use follow-up expansion
to increase the expansion force in response to increases in
tension loading beyond the service load level (preload) or to
adjust for changes in the state of the base material (cracking).
Keying: Undercut anchors and, to a lesser degree, certain
types of expansion anchors, rely on the interlock of the anchor
with deformations in the hole wall to resist the applied tension
loading. The (bearing) stresses developed in the base material
at the interface with the anchor bearing surfaces can reach
relatively high levels without crushing due to the triaxial nature
of the state of stress. Undercut anchors like the Hilti HDA
offer much greater resilience to variations in the base material
conditions and represent the most robust solution for most
anchoring needs.
Bonding (adhesion): Adhesive anchor systems utilize the
bonding mechanism that takes place between the adhesive
and the anchor element, and the adhesive and the concrete,
to transfer the applied load from the anchor element into the
concrete. The degree of bonding available is influenced by
the condition of the hole wall at the time of anchor installation.
Injection anchor systems like Hiltis HIT-HY 150 MAX-SD offer
unparalleled flexibility and high bond resistance for a wide
variety of anchoring applications.
Hybrid anchor elements like the Hilti HIT-Z threaded rod
combine the functionality of an adhesive anchor system with
the working principle of a torque-controlled expansion anchor
for increased reliability under adverse job-site conditions.
Shear resistance: Most anchors develop resistance to shear
loading via bearing of the anchor element against the hole wall
close to the surface of the base material. Shear loading may
cause surface spalling resulting in significant flexural stresses
and secondary tension in the anchor element.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 19
Fastening Technology
3.1.4.1 Prestressing
of Anchors
In general, properly installed anchors do not exhibit noticeable
deflection at the expected service load levels due to the
application of the prescribed installation torque. External
tension loading results in a reduction of the clamping force in
the connection with little increase in the corresponding bolt
tension force. Shear loads are resisted by a combination of
bearing and friction resulting from the anchor preload forces.
At load levels beyond the clamping load, anchor deflections
increase and the response of the anchor varies according to
the anchor force-resisting mechanism. Expansion anchors
capable of follow-up expansion show increased deflections
corresponding to relative movement of the cone and
expansion elements. Adhesive anchors exhibit a change
in stiffness corresponding to loss of adhesion between the
adhesive and the base material whereby tension resistance at
increasing displacement levels is provided by friction between
the uneven hole wall and the adhesive plug. In all cases,
increasing stress levels in the anchor bolt/element result in
increased anchor displacements.
Fatigue
Chemical resistance/durability
Concrete cracking
Creep
Corrosion
Freeze/thaw conditions
Fire
High temperature
Seismic loading
Corrosion
Fatigue
Fire
Concrete cracking
Seismic Loading
All Hilti adhesive anchor systems suitable for use with the
Strength Design Method have been tested for sustained
loading conditions as per ACI 355.4 and ICC-ES Acceptance
Criteria AC308. Contact Hilti for additional information.
20 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
A Vc
= projected concrete failure area of a single anchor
or group of anchors, for calculation of strength in
shear, in.2 (mm2)
A Vco
=
c
= distance from anchor centerline to the closest
free edge of concrete, in. (mm)
cac
=
ca2
= distance from center of an anchor shaft to the
edge of concrete in the direction perpendicular
to ca1, in. (mm)
ccr,Na or cNa =
dh
= diameter of clearance hole in attachment
(e.g. baseplate), in. (mm)
dnom
do
e'N
=
e'V
=
'c
= specified concrete compressive strength,
psi (MPa)
fya
futa
= specified bolt minimum ultimate strength,
psi (MPa)
h or ha = thickness of member in which an anchor is
located, as measured parallel to anchor axis,
in. (mm)
hef
hmin
ca,max
= maximum distance from the center of an
anchor shaft to the edge of concrete, in. (mm)
h0
= depth of full diameter hole in base material,
in. (mm)
ca,min
= minimum distance from the center of an anchor
shaft to the edge of concrete, in. (mm)
kcr
= coefficient for basic concrete breakout strength in
tension, cracked concrete
ca1
=
kuncr
= coefficient for basic concrete breakout strength in
tension, uncracked concrete
kcp
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 21
Fastening Technology
smin
= minimum spacing between adjacent
loaded anchors, in. (mm)
th
tfix
= maximum thickness of attachment
(e.g. baseplate) to be fastened, in. (mm)
MsO
= characteristic value for the bending moment
corresponding to rupture, in-lb (Nm)
n
Na
= nominal bond strength in tension of a single
adhesive anchor, lb (kN)
Nag
= nominal bond strength in tension of a group of
adhesive anchors, lb (kN)
Nao
= characteristic tension capacity of a single
adhesive anchor in tension as limited by bond/
concrete failure, lb (kN)
Nb
= basic concrete breakout strength in tension
of a single anchor in cracked concrete, lb (kN)
Nba
= basic bond strength in tension of a single
adhesive anchor, psi (MPa)
Ncb
= nominal concrete breakout strength in tension of
a single anchor, lb (kN)
Ncbg
= nominal concrete breakout strength in tension of
a group of anchors, lb (kN)
Nn
Np
= pullout strength in tension of a single anchor in
cracked concrete, lb (kN)
Npn,f'c
= nominal pullout strength in tension of a single
post-installed mechanical anchor, lb (kN)
Npn
= nominal pullout strength in tension of a single
anchor, lb (kN)
Nsa
= nominal strength of a single anchor or
individual anchor in a group of anchor in tension
as governed by the steel strength, lb (kN)
Nsb
= side face blowout strength of a single
anchor, lb (kN)
Nsbg
= side face blowout strength of a group of
anchors, lb (kN)
Nua
= factored tensile force applied to an anchor or an
individual anchor in a group of anchors, lb (kN)
s
scr,Na
=
Tinst
= recommended anchor installation torque,
ft-lb (Nm)
Tmax
Vb
= basic concrete breakout strength in shear
of a single anchor in cracked concrete, lb (kN)
Vcb
= nominal concrete breakout strength in shear of a
single anchor, lb (kN)
Vcbg
= nominal concrete breakout strength in shear of a
group of anchors, lb (kN)
Vcp
= nominal concrete pryout strength of a single
anchor, lb (kN)
Vcpg
= nominal concrete pryout strength of a group of
anchors, lb (kN)
Vn
Vsa
= nominal shear strength of a single anchor or
individual anchor in a group of anchors as
governed by the steel strength, lb (kN)
Vua
= factored shear force applied to a single
anchor or group of anchors, lb (kN)
cr
=
uncr
=
c,N
= factor used to modify tensile strength of
anchors based on presence or absence of cracks
in concrete
c,p
= factor used to modify pullout strength of
anchors based on presence or absence of cracks
in concrete
c,V
=
22 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ec,N
= factor used to modify tensile strength of anchors
based on eccentricity of applied loads
ec,V
= factor used to modify shear strength of anchors
based on eccentricity of applied loads
ed,N
= factor used to modify tensile strength of anchors
based on proximity to edges of concrete member
ed,V
= factor used to modify shear strength of anchors
based on proximity to edges of concrete member
h,v
= factor used to modify the shear strength of
anchors located in a concrete member where
ha < 1.5ca1
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 23
Fastening Technology
Condition A Condition B
Cast-in headed
studs, headed bolts,
or hooked bolts . . . . . 0.75 . . . . . . . . 0.70
Post-installed anchors:
3.1.6.4 Strength
reduction factors
Strength reduction factors are intended to account for
possible reductions in resistance due to normally
expected variations in material strengths, anchor installation
procedures, etc. Relevant strength reduction factors as
given in ACI 318-11 Section D.4.3 for load combinations
in accordance with Section 9.2 of the same document are
provided below.
Anchor governed by a ductile steel element:
N (D-3)
A Nco ed,N c,N cp,N b
The nominal concrete breakout strength of anchor groups is
likewise determined as follows:
A
Ncbg = Nc ec,N ed,N c,N cp,N Nb (D-4)
A Nco
where:
A Nco
=
= 9 h ef2 (D-5)
24 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ec,N
=
1
=
(D-8)
1
2e'N
1+
3h ef
0.7 + 0.3
c,N
=
cp,N
Nb
=
= kca
1.5hef
s2
1.5hef
A Nc
Example of determination of A Nc
ca,min
s1
ed,N
=
ca,1
ca,2
A Nc
=
projected concrete failure area of a single
anchor or group of anchors approximated
as the base of the rectilinear geometrical
figure that results from projecting the failure
surface outward 1.5hef from the centerlines
of the anchor, or in the case of a group of
anchors, from a line through a row of
adjacent anchors. ANc shall not exceed
nANco, where n is the number of anchors in
the group that resist tension
e'N
c,P
=
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 25
Fastening Technology
N (D-18)
A Nao ed,Na cp,Na ba
The nominal concrete breakout strength of anchor groups is
likewise determined as follows:
A
Nag = Na ec,Na ed,Na cp,Na Nba (D-19)
A Nao
where:
=
ANao
= (2cNa)2 (D-20)
cNa
uncr
= 10da (D-21)
=
ANa
1100
ec,Na
=
cp,Na
=
Nba
=
acrdahef (D-22)
where:
=
A Vco
= 4.5(ca1)2 (D-32)
26 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ec,V
=
ed,V
=
c,V
=
h,V
=
1.5c
ha
a1
= (D-39)
Vb
=
basic concrete breakout strength in shear
of a single anchor in cracked concrete,
determined as the smaller of (D-33) and
(D-34).
Ref. ACI 318-11 Section D.6.2.2 for limiting
values of e:
(( )
0.2
e
7
da a 'c (ca1)1.5
= (D-33)
d
9a 'c (ca1)1.5
= (D-34)
3.1.6.7 Interaction
Strength Design
Where anchors are loaded simultaneously in tension and
shear, interaction must be considered. In accordance with
ACI 318-11 Section D.7, interaction may be checked
as follows:
If Vua 0.2Vn
Nn Nua
N
[ N
] + [ VV ] 1.2
ua
and
ua
(D-42)
ua
1.0
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 27
Fastening Technology
Refer to ACI 318 -11 Section D.8, ACI 355.2, ACI 355.4, or
the relevant ICC-ES acceptance criteria for the geometry
requirements for cast-in-place and post-installed anchors.
whereby:
M
=
MS
= Ms0
( 1-N
N )
ua
sa
Ms0
=
characteristic flexural resistance of single
anchor
= 1.2 S fu,min
fu,min
=
S
=
( * d3) / 32
z + (n do)
z
=
do
n
=
3.1.7 H
ilti Simplified Strength
Design Tables
The Hilti Simplified Strength Design Tables are not a new
method of designing an anchor that is different than the
provisions of ACI 318 Appendix D. Rather, it is a series of
pre-calculated tables and reduction factors meant to help
the designer create a quick calculation of the capacity of the
Hilti anchor system, and still be compliant with the codes and
criteria of ACI.
The Hilti Simplified Strength Design Tables are formatted
similar to the Allowable Stress Design (ASD) tables and
reduction factors which was a standard of practice for design
of post-installed anchors.
The Hilti Simplified Strength Design Tables combine the
simplicity of performing a calculation according to the ASD
method with the code-required testing, evaluation criteria and
technical data in ACI 318 Appendix D.
28 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
Adhesive anchors
Vn = Vcp
Nua
Vua
____ + ____ 1.2
N
Vdes
des
where:
Tension:
Ndes = n min | Nn AN RN ; Nsa |
Shear:
Vdes = n min | Vn AV RV HV ; Vsa |
where:
n =
number of anchors
Ndes = design resistance in tension
Nn = design strength in tension considering
concrete breakout, pullout, or bond failure
Nsa = design strength in tension considering
steel failure
Vdes = design resistance in shear
Vn = design strength in shear considering
concrete failure
Vsa = design strength in shear considering steel
failure
AN = adjustment factor for spacing in tension
RN = adjustment factor for edge distance in
tension
AV =
adjustment factor for spacing in shear
RV = adjustment factor for edge distance in shear
HV = adjustment factor for concrete thickness in
shear (this is a new factor that ASD did not
use previously)
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 29
Fastening Technology
ASD
Vdes
Vdes,ASD = _____
ASD
where:
ASD = Conversion factor calculated as a weighted
average of the load factors for the
controlling load combination.
An example for the calculation of ASD is as follows:
Controlling strength design load combination is 1.2D
+ 1.6L, % contribution is 30% D, 70% L
ASD =
Appendix D.
30 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
IMPORTANT NOTE:
Asl
Ast
c
= distance from anchor centerline to the closest
free edge of base material, in. (mm)
ccr
cmin
dbit
dh
= diameter of clearance hole in attachment
(e.g. baseplate), in. (mm)
dnom
do
dw
c
= concrete compressive strength as measured by
testing of cylinders, psi (MPa)
'c
= specified concrete compressive strength,
psi (MPa)
RN
= adjustment factor for edge distance,
tension loading
RV1
= adjustment factor for edge distance, shear
loading perpendicular and towards free edge
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 31
Fastening Technology
RV3
= adjustment factor for edge distance, shear
loading perpendicular and away from free edge
Vd
Vrec
fy
Fy
Fu
= specified bolt minimum ultimate strength,
psi (MPa)
h
= thickness of member in which anchor is
embedded as measured parallel to anchor axis,
in. (mm)
hef
hmin
hnom
= distance between base material surface and
bottom of anchor (prior to setting is applicable),
in. (mm)
ho
= depth of full diameter hole in base material,
in. (mm)
th
Nrec = Nallow RN A
Vrec = Vallow RV A
where:
Nallow
Nd
Nrec
Nallow
= allowable load (based on the mean value from
laboratory testing to failure and a global safety
factor)
Nrec
scr
= critical spacing between adjacent
loaded anchors, in. (mm)
sW
t fix
= maximum thickness of attachment
(e.g. baseplate) to be fastened, in. (mm)
Tinst
= recommended anchor installation torque,
ft-lb (Nm)
Tmax
Vrec
Vallow
RN
= adjustment factor for edge distance,
tension loading
smin
= minimum spacing between adjacent
loaded anchors, in. (mm)
3
RV1
= adjustment factor for edge distance, shear loading
perpendicular and toward free edge
RV2
= adjustment factor for edge distance, shear loading
parallel to free edge
RV3
= adjustment factor for edge distance, shear loading
perpendicular and away from free edge
Adjustment factors are multiplicative and are applied for all
edge and spacing conditions that are less than ccr and scr,
respectively.
32 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
where:
Nd
Vd
= exponent, 1 2
M
= adjustment of bending moment associated with
rotational restraint, where 1 M 2
s min s < s cr
where:
s min
= minimum spacing between loaded
anchors; and
s cr
= critical spacing between loaded anchors
(anchor spacing equal to or greater than the
one requiring a reduction factor)
Similarly, for near-edge anchors, the edge distance
adjustment factor(s) are applicable for cases where the anchor
edge distance is such that:
c min c < c cr
where:
c min
c cr
= critical edge distance (anchor edge distance
equal to or greater than the one requiring a
reduction factor)
[ ] [ ]
Vd
N d
+
N rec Vrec
1.0
Vrec
= recommended shear load corresponding
to bending
MuM,5% = characteristic flexural resistance of a single anchor
N
1- d
= 1.2 S futa
N rec
futa
= minimum ultimate tensile strength of anchor
S
= elastic section modulus of anchor bolt
at concrete surface (a uniform cross section
is assumed)
= z + (n do )
z
= distance from center of base plate to surface of
concrete (standoff distance)
d0
n
= 0, for static loading with clamping at the concrete
surface as provided by a nut and washer
assembly (required for mechanical anchors);
= 0.5, for static loading without clamping at the
concrete surface, e.g., adhesive anchor without
nut and washer at concrete surface
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 33
Fastening Technology
34 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 35
Fastening Technology
"
7VB
7VB
Dimensional
parameters:
d0
= 5/8 in.
hnom = 4.75 in.
hef = 4 in.
tfixture = 1/2 in.
=
=
=
=
=
/ VB
Z
"
4FDUJPO""
h
sx
sy
c+x
c+y
Given:
Normal weight concrete, 'c = 4,000 psi; cracked concrete conditions assumed; seismic design category (SDC) C
Reference ACI 318-11, Ch. 9 and ICC-ES ESR-1917 for LRFD Factors
=> Assume condition B for all factors
Carbon steel 5/8" x 6" KWIK Bolt TZ anchors; anchors are considered ductile steel elements
4 anchors in tension: no tension eccentricity
4 anchors in shear: no shear eccentricity
[Seismic without o (D.3.3.4.3(a))] Nua = 1,500 lb Vua(-y direction) = 3,000 lb
[Seismic with o (D.3.3.4.3(d))]
Nua = 3,000 lb Vua(-y direction) = 6,000 lb
12 in.
4 in.
4 in.
6 in.
8 in.
Things to check:
Geometry requirements
Tension design strengths
Shear design strengths
References:
Mechanical anchor KWIK Bolt TZ
ACI 318-11, Appendix D
ICC-ES ESR-1917
ESR ref.
D.8
RD.8
Section 4.1.10
Table 1
Table 3
Figure 4
D.5.2.1
RD.5.2.1
BDDFQUBCMFFEHFEJTUBODF
BOETQBDJOHDPNCJOBUJPOT
JOTIBEFEBSFB
spacing (s) in
7
(3.25 in, 5.875 in)
6
5
4
(4.25 in, 3.00 in)
3
2
1
1
36 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.
D.6.2.1
RD.6.2.1
Section 4.1.10
Table 1
Table 3
Figure 4
D.8
RD.8
Section 4.1.10
Table 1
Table 3
Figure 4
D.5.1.2
Section 4.1.2
D.5.1.2
Eq. (D-2)
Table 3
D.5.2.1 (b)
Eq. (D-4)
Section 4.1.3
c+x = 6 in.
c+y = 8 in.
sy = 4 in.
c-y =
cmax = 1.5 hef = (1.5) (4 in.) = 6 in.
if c 6 in. use 1.5 hef
smax = 3 hef = (3) (4 in.) = 12 in.
if s > 12 in. no group action
ANc = (c-x + sx + c+x ) (c+y + sy + c-y ) = (6 in. + 4 in. + 6 in.) (6 in. + 4 in. + 6 in.) = 256 in2
ANc0 = (9) (hef)2 = (9) (4 in.)2 =144 in2
D.5.2.1
RD.5.2.1
Eq. (D-5)
D.5.2.4
Eq. (D-8)
D.5.2.5
Eq. (D-9)
D.5.2.6
D.5.2.7
D.5.2.2
Eq. (D-6)
Table 3
D.5.2.1 (b)
Eq. (D-4)
Table 3
OK
= 750 lb / anchor
ANc
ec,N ed,N c,N cp,N Nb
ANco
c-x = sx = 4 in.
The smallest edge distance (cmin) = 6 in. = 1.5hef no reduction for edge distance
Note: cracked concrete conditions have been assumed
c,N = 1.0
256 in2
144 in2
ed,N = 1.0
cp,N = 1.0
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 37
Fastening Technology
'c
2,500
Note: Pullout strength does not need to be considered. Reference Table 3 in ESR-1917.
Calculate nominal steel strength in shear: Vsa
Four anchors in shear. Highest load acting on a single anchor = Vua / 4 = 6,000 lb / 4-anchors = 1,500 lb / anchor
Steel strength: Vsa = Veq = 7,600 lb / anchor
Calculate nominal concrete breakout strength in shear: Vcbg =
AVc
ec,V ed,V c,V h,V Vb
AVco
c-x = sx = 4 in.
c+x = 6 in.
c+y = 8 in.
sy = 4 in. c-y =
Note: Shear load acts in the y direction. c-y = no concrete breakout assumed in the y direction
Concrete breakout for shear parallel to the edge (+x direction) should be checked per D.6.2.1(c).
Assume the full shear load acts on the row of anchors nearest to the x+ edge ca1 = 6 in.
1.5ca1 = (1.5) (6 in.) = 9 in.
if c 9 in. use 1.5 ca1
h = 12 in.
smax = 3 ca1 = (3) (6 in.) = 18 in.
if s > 18 in. no group action
AVc = (c+y + sy + c-y ) (MINIMUM [1.5ca1 ; h]) = (8 in. + 4 in. + 9 in.) (9 in.) = 189 in2
AVc0 = (4.5) (ca1 )2 = (4.5) (6 in.)2 =162 in2
ESR ref.
Section 4.1.8.2
Table 3
Table 3
D.6.1.2
Section 4.1.5
D.6.1.2
Eq. (D-29)
Table 3
D.6.2.1 (b)
Eq. (D-31)
Section 4.1.6
D.6.2.1 (c)
D.6.2.1
RD.6.2.1
Eq. (D-32)
D.6.2.5
Eq. (D-36)
D.6.2.6
Eq. (D-38)
D.6.2.7
D.6.2.8
Eq. (D-39)
D.6.2.2
Eq. (D-33)
Eq. (D-34)
Table 3
D.6.2.1 (b)
D.6.2.1 (c)
Eq. (D-31)
Table 3
The edge distances perpendicular to the direction of the shear load are defined as ca2.
Note: D.6.2.1(c) permits ed,V = 1.0 to be used when calculating shear parallel to an edge.
The ed,V calculation in this example is conservative.
c a2+y
8 in.
ed,V = 0.7 + 0.3
= 0.7 + 0.3
= 0.967
ca2+y = 8 in. ca2-y =
1.5ca1
9 in.
( )
1.5ca1
ha
( )
e
0.2
danchor
danchor
c' (ca1)1.5
4 in.
0.625 in.
(b) Vb = 9 a
0.2
(1.0)
0.625 in.
189 in2
162 in2
38 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.
D.6.3.1 (b)
Eq. (D-41)
Section 4.1.7
Ncbg = 15,290 lb
D.6.3.1 (b)
Eq. (D-41)
Table 3
Summary
Anchors are ductile steel elements check D.3.3.4.3 (a) first
[Ductility check] Tension calculations per D.3.3.4.3 (a)
Tension
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
17,170 lb/anchor
20,604 lb/anchor
375 lb/anchor
1.80%
OK
Concrete breakout
15,290 lb
1,500 lb
17.30%
OK Controls
Pullout strength
N/A
N/A
N/A
N/A
N/A
Steel strength does not control: D.3.3.4.3 (a) is, therefore, not satisfied. Need to satisfy D.3.3.4.3 (d)
Tension calculations per D.3.3.4.3 (d)
Tension
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
17,170 lb/anchor
steel = 0.75
12,878 lb/anchor
750 lb/anchor
5.80%
OK
Concrete breakout
15,290 lb
seismic = 0.75
concrete = 0.65
7,454 lb
3,000 lb
40.30%
OK controls
Pullout strength
N/A
N/A
N/A
N/A
N/A
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
7,600 lb/anchor
steel = 0.65
4,940 lb/anchor
1,500 lb/anchor
30.40%
OK
Concrete breakout
16,822 lb
seismic = 0.75
concrete = 0.70
8,832 lb
6,000 lb
68%
OK controls
Pryout
30,580 lb
seismic = 0.75
concrete = 0.70
16,055 lb
6,000 lb
37.40%
OK
ESR ref.
D.7
Section 4.1.9
D.7.1
D.7.2
D.7.3
Eq. (D-42)
RD.7
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 39
Fastening Technology
"
=
=
=
6 in.
5 in.
2 in.
U GJYUVSF
Z
h
s
c
/ VB
IOPN
7VB
Dimensional
parameters:
d0
= 1/2 in.
hnom = 3 in.
hef = 2.16 in.
tfixture = 3/8 in.
"
IFG
Objective:
Determine the controlling
design strength in tension
and shear
4FDUJPO""
Given:
Normal weight concrete, 'c = 4,000 psi; cracked concrete conditions assumed; seismic design category (SDC) C
Reference ACI 318-08, Ch. 9 and ICC-ES ESR-3027 for LRFD Factors
=> Assume condition B for all factors
Carbon steel 1/2" x 4" KWIK HUS-EZ anchors. Anchors are considered non-ductile steel elements
2 anchors in tension: No tension eccentricity
2 anchors in shear: No shear eccentricity
[Seismic with 0 (D.3.3.4.3 (d))]
Nua = 1,000 lb Vua = 800 lb towards the fixed edge
Things to check:
Geometry requirements
Tension design strengths
Shear design strengths
References:
Mechanical anchor KWIK HUS-EZ
ACI 318-11, Appendix D
ICC-ES ESR-3027
ESR Ref.
D.8
RD.8
D.5.2.1
RD.5.2.1
D.8
RD.8
D.6.2.1
RD.6.2.1
Section 4.1.10
Table 2
Section 4.1.10
Table 2
Steel strength:
Section 4.1.10
D.8
RD.8
Table 1
Table 2
D.5.1.2
Section 4.1.2
D.5.1.2
Eq. (D-2)
Table 3
40 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.
D.5.2.1 (b)
Eq. (D-4)
Section 4.1.3
c-x = sx = 5 in.
c+x =
c+y = c-y = 2 in.
cmax = 1.5 hef = (1.5) (2.16 in.) = 3.24 in. if c 3.24 in. 1.5 hef
smax = 3 hef = (3) (2.6 in.) = 6.48 in.
if s > 6.48 in. no group action
ANc = (c-x + sx + c+x) (c+y + c-y) = (3.24 in. + 5 in. + 3.24 in.) (3.24 in. + 2 in.) = 60.15 in2
ANc0 = (9) (hef)2 = (9) (2.16 in.)2 =42 in2
D.5.2.1
RD.5.2.1
Eq. (D-5)
D.5.2.4
Eq. (D-8)
D.5.2.5
Eq. (D-10)
D.5.2.6
D.5.2.7
D.5.2.2
Eq. (D-6)
Table 3
D.5.2.1 (b)
Eq. (D-4)
Table 3
Section 4.1.8.2
Table 3
D.6.1.2
Section 4.1.5
D.6.1.2
Eq. (D-29)
Table 4
D.6.1.2 (b)
Eq. (D-31)
Section 4.1.6
D.6.2.1
RD.6.2.1
Eq. (D-32)
D.6.2.5
Eq. (D-36)
Edge projections in x+ and x- directions are assumed to be infinite for purposes of concrete breakout
calculations in shear ed,V = 1.0
D.6.2.6
Eq. (D-37)
D.6.2.7
( )
ANc
ec,N ed,N c,N cp,N Nb
ANco
ca,min
2 in.
= 0.70 + 0.3
= 0.885
1.5hef
(1.5) (2.16 in.)
Note: cracked concrete conditions have been assumed. c,N = 1.0; cp,N = 1.0
Note: normal weight concrete a = 1.0. Nb = kc,cr a c' (hef)1.5 = (17) (1.0) 4,000 (2.16 in.)1.5 = 3,413 lb
Ncbg =
60.15 in2
(1.0) (0.85) (1.0) (1.0) (3,413 lb) = 4,326 lb
42 in2
'c
2500
Note: Pullout strength does not need to be considered. Reference Table 3 in. ESR-3027.
Calculate nominal steel strength in shear: Vsa
Two anchors in shear
Highest load acting on a single anchor = Vua / 2 = 800 lb / 2-anchors = 400 lb / anchor
AVc
ec,V ed,V c,V h,V Vb
AVco
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 41
Fastening Technology
1.5ca1
ha
ESR ref.
D.6.2.8
Eq. (D-39)
( )
e
da
0.2
da
c' (ca1)1.5
D.6.2.2
Eq. (D-33)
Eq. (D-34)
0.2
(1.0)
0.50 in.
Table 4
( )
33 in2
18 in2
D.6.2.1 (b)
Eq. (D-31)
Table 4
D.6.3.1 (b)
Eq. (D-41)
Section 4.1.7
Ncbg = 4,326 lb
D.6.3.1 (b)
Eq. (D-41)
Table 4
Summary
Cannot check D.3.3.4.3 (a) because KWIK HUS-EZ is a non-ductile anchor element. Check D.3.3.4.3 (d)
Tension calculations per D.3.3.4.3(d)
Tension
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
18,120 lb/anchor
steel = 0.65
11,778 lb/anchor
500 lb/anchor
4.30%
OK
Concrete breakout
4,326 lb
seismic = 0.75
concrete = 0.65
2,109 lb
1,000 lb
47.40%
OK controls
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
5,547 lb/anchor
steel = 0.60
3,328 lb/anchor
400 lb/anchor
12.00%
OK
Concrete breakout
2,174 lb
seismic = 0.75
concrete = 0.70
1,141 lb
800 lb
70.10%
OK controls
Pryout
4,326 lb
seismic = 0.75
concrete = 0.70
2,271 lb
800 lb
35.23%
OK
42 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.
D.7
Section 4.1.9
(0.2)Vcbg
Vua = 800 lb
Vua > (0.2)Vcbg
D.7.1
D.7.2
D.7.3
Eq. (D-42)
RD.7
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 43
Fastening Technology
"
.VB
7VB
POMZ
BODIPST
BSFJOUFOTJPO
Dimensional
parameters:
hef
= 15 in.
h
= 24 in.
s x
= 8 in.
sy1
= 12 in.
sy2
= 12 in.
c+x
= 6 in.
c-y
=-
da
= 1 in.
dhole = 1.125 in.
"
4FDUJPO""
Given:
Normal weight concrete, c = 6,000 psi; cracked concrete conditions assumed; seismic design category (SDC) D
Use ACI 318-11 Ch. 9 and ICC-ES ESR-3187 for LRFD Factors
=> Assume condition B for all factors and temperature range A
HIT HY 200 Adhesive with 1" ASTM A193 B7 threaded rod; anchors are considered ductile steel elements
Four anchors in tension: Tension eccentricity = 2.592 in.
Six anchors in shear: no eccentricity in shear
[Seismic without 0 (D.3.3.4.3(a))] Mua (x-axis) = 184,000 in-lb Vua = 6,800 lb (+x direction)
[Seismic with 0 (D.3.3.4.3(d))] Mua (x-axis) = 230,000 in-lb Vua = 8,500 lb (+x direction)
Things to check:
Geometry requirements
Tension design strengths
Shear design strengths
Sustained load per D.4.1.2
References:
Adhesive Anchor: HIT-HY 200
ACI 318-11, Appendix D
ICC-ES Acceptance Criteria AC308*
ICC-ES ESR-3187*
* While ICC-ES AC 308 is not harmonized with ACI 355.4, Hilti feels that designs according to ACI 318-11 Appendix D are appropriate.
Determine Distribution of Loads on Anchor Group
Anchor
Seismic tension
without 0
Seismic tension
with 0
Seismic shear
without 0
Seismic shear
with 0
Sustained tension
load (non seismic)
3,205 lb/anchor
4,006 lb/anchor
1,133 lb/anchor
1,417 lb/anchor
1,742 lb/anchor
1,271 lb/anchor
1,589 lb/anchor
1,133 lb/anchor
1,417 lb/anchor
691 lb/anchor
1,133 lb/anchor
1,417 lb/anchor
3,205 lb/anchor
4,006 lb/anchor
1,133 lb/anchor
1,417 lb/anchor
1,742 lb/anchor
1,271 lb/anchor
1,589 lb/anchor
1,133 lb/anchor
1,417 lb/anchor
691 lb/anchor
1,133 lb/anchor
1,417 lb/anchor
Resultant
8,952 lb
11,190 lb
6,800 lb
8,500 lb
44 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.*
D.8
RD.8
D.5.2.1
RD.5.2.1
Section 4.1.9
Table 12
D.5.1.2
Section 4.1.2
D.5.1.2
Eq. (D-2)
Table 11
D.5.2.1 (b)
Eq. (D-4)
Section 4.1.3
D.5.2.1
RD.5.2.1
Eq. (D-4)
D.5.2.4
Eq. (D-8)
D.5.2.5
Eq. (D-10)
D.5.2.6
D.5.2.7
D.5.2.2
Eq. (D-6)
Table 12
D.5.2.1 (b)
Eq. (D-4)
Table 12
D.5.5.1
(D-19)
Section 4.1.4
D.5.3.7 (b)
Eq. (D-16b)
D.5.5.1
(D-20)
(D-21)
Section 4.1.4
D.5.3.7
Eq. (D-16b to f)
D.5.3.8
Table 14
sx = 8 in.
c+x = 6 in.
ANc
ec,N ed,N c,N cp,N Nb
ANco
sy2 = 12 in.
c-y =
ANc = (c-x + sx + c+x) (c+y + sy2 + c-y) = (22.5 in. + 8 in. + 6 in.) (22.5 in. + 12 in. + 22.5 in.) = 2,080.5 in2
ANc0 = (9) (hef)2 = (9) (15 in.)2 =2,025 in2
Note: tension eccentricity determined using PROFIS Anchor software.
eN' = 2.592 in. (Distance from Nresultant to C.O.G. of the anchors intension)
ec,N =
( ) (
1
1+
2eN'
1+
3hef
( )
ca,min
1.5hef
= 0.7 + 0.3
= 0.8971
6 in.
= 0.78
(1.5) (15 in.)
Note: cracked concrete conditions have been assumed. c,N = 1.0; cp,N = 1.0
Note: cracked concrete conditions have been assumed. Normal weight concrete a = 1.0
Nb = kc,cr a
Ncbg =
2,080.5 in2
(0.897) (0.78) (1.0) (1.0) (76,500) = 54,991 lb
2,025 in2
k,uncr
1,100
ANa
ed,Na ec,Na cp,Na Nba
ANao
cNa = 13.10 in.
smax = sNa
A Na = (c-x+ sx+ c+x) (c+y+ sy2+ c-y) = (13.10 in. + 8 in. + 6 in.) x (13.10 in. + 12 in. + 13.10 in.) = 1035.22 in2
A Nao = (2ccr,Na)2 = [ (2) (13.10 in.) ]2 = 686.44 in2
* While ICC-ES AC 308 is not harmonized with ACI 355.4, Hilti feels that designs according to ACI 318-11 Appendix D are appropriate.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 45
Fastening Technology
ESR ref.*
D.5.5.4
(D-25)
Section 4.1.4
D.5.3.12
Eq. (D-16m)
D.5.5.3
(D-23)
Section 4.1.4
D.5.3.11
Eq. (D-16j)
D.5.5.5
(D-26)
Section 4.1.4
D.5.3.14
Eq. (D-16o)
D.5.5.2
(D-22)
Section 4.1.4
D.5.3.9
Eq. (D-16f)
Table 14
D.5.5.1(b)
(D-19)
Section 4.1.4
D.5.3.7 (b)
Eq. (D-16b)
D.6.1.2
Section 4.1.5
D.6.1.2
Eq. (D-29)
Table 11
D.6.2.1 (b)
Eq. (D-31)
Section 4.1.6
D.6.2.1
RD.6.2.1
Eq. (D-32)
D.6.2.5
Eq. (D-36)
D.6.2.6
Eq. (D-37)
D.6.2.7
D.6.2.8
Eq. (D-39)
ca,min
cNa
= 0.7 + 0.3
6 in.
13.10 in.
= 0.837
1
( )
e'N
cNa
1+
2.592 in.
13.10 in.
= 0.835
k,seis = k,cr
Nba = (a) (k,cr ) () (danchor ) (hef ) = (1.0) (964 psi) () (1 in.) (15 in.) = 45,427 lb
Nag =
1035.22 in2
(0.835) (0.837) (1.0) (45,427 lb) = 47,880 lb
686.44 in2
AVc
ec,V ed,V c,V h,V Vb
AVco
ca1 = 6 in.
sx = 8 in. ca2- = ca2+ =
1.5ca1 = 9 in.
Projection from surface down = MINIMUM [1.5ca1 ; h] = MINIMUM [9 in. ; 24 in.] = 9 in.
If ca2,min > 1.5 ca1 use ca2 = 1.5ca1
AVc = (ca2- + sy1 + sy2 + ca2+) (1.5cca1) = (1.5ca1 + 12 in. + 12 in. + 1.5ca1) (1.5ca1)
= (9 in. + 12 in. + 12 in. + 9 in.) (9 in.) = 378 in2
AVc0 = (4.5) (ca1)2 = (4.5) (6 in)2 = 162 in2
1.5ca1
ha
* While ICC-ES AC 308 is not harmonized with ACI 355.4, Hilti feels that designs according to ACI 318-11 Appendix D are appropriate.
46 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.*
D.6.2.2
Eq. (D-33)
Eq. (D-34)
D.6.2.1 (b)
Eq. (D-31)
Section 4.1.6
D.6.3.1 (b)
Section 4.1.7
D.6.3.2 (b)
( )
8 in.
1 in.
(b) Vb = 9 a
0.2
(1.0)
1 in.
378 in2
162 in2
Calculate nominal concrete pryout strength in shear: Vcpg = (kcp) (MINIMUM [Ncbg ; Nag ])
Eq. (D-41)
c-x = sx = 8 in.
c+x = 6 in.
c+y = sy1 = 12 in.
sy2 = 12 in.
c-y = 12 in.
cmax = 1.5 hef = 22.5 in. if c 22.5 in. use 1.5 hef
smax = 3 hef = 45 in.
if s > 45 in., no group action
ANc = (c-x + sx + c+x ) (c+y + sy1 + sy2 + c-y ) = (22.5 in. + 8 in. + 6 in.) (22.5 in. + 12 in. + 12 in. + 22.5 in.) = 2,518.5 in2
ANc0 = (9) (hef)2 = (9) (15 in.)2 =2025 in2
Note: tension eccentricity not considered for pryout. ec,N = 1.0
ed,N = 0.7 + 0.3
( )
ca,min
1.5hef
= 0.7 + 0.3
6 in.
= 0.78
c,N = 1.0
cp,N = 1.0
Note: cracked concrete conditions have been assumed. Normal weight concrete a = 1.0.
Nb = kc,cr a
Ncbg =
2,518 in2
2,025 in2
c-x =
sx = 8 in.
c+x = 6 in.
c+y =
sy1 = 12 in.
sy2 = 12 in.
D.5.2.1
RD.5.2.1
Eq. (D-5)
D.5.2.4
Eq. (D-8)
D.5.2.5
Eq. (D-10)
D.5.2.6
D.5.2.7
D.5.2.2
Eq. (D-6)
Table 12
D.5.2.1 (b)
Eq. (D-4)
D.5.5.1
(D-20)
(D-21)
Section 4.1.4
D.5.3.7
Eq. (D-16b to f)
D.5.3.8
Table 14
D.5.5.3
(D-23)
Section 4.1.4
D.5.3.11
D.5.5.4
(D-25)
Section 4.1.4
D.5.3.12
Eq. (D-16m)
c-y =
cNa = 10 (1 in.) 1,889 = 13.10 in.; if c cNa use cNa; if s > sNa no group action [sNa = 2cNa]
1,100
A Na = (c-x + sx + c+x) (c+y + 2cy2 + c-y) = (13.10 in. + 8 in. + 6 in.) x (13.10 in. + 12 in.+ 12 in. + 13.10 in.) = 1,360.4 in2
A Nc0 = (scr,Na)2 = (26.2)2 = 686.44 in2
Note: tension eccentricity not considered for shear. ec,Na = 1.0
( )
ca,min
cNa
= 0.7 + 0.3
6 in.
= 0.837
13.10 in.
Eq. (D-30b)
* While ICC-ES AC 308 is not harmonized with ACI 355.4, Hilti feels that designs according to ACI 318-11 Appendix D are appropriate.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 47
Fastening Technology
ESR ref.*
D.5.5.5
(D-26)
Section 4.1.4
D.5.3.14
Eq. (D-16o)
D.5.5.2
(D-22)
D.5.5.1 (b)
(D-19)
Section 4.1.4
D.5.3.9
Eq. (D-16f)
Table 14
D.5.3.7 (b)
Eq. (D-16b)
D.6.3.1 (b)
Eq. (D-41)
Section 4.1.7
D.6.3.2(b)
Eq. (D-30b)
D.4.1.2
(D-1)
Note: cracked concrete conditions have been assumed. Normal weight concrete: a = 1.0
'c = 6,000 psi (1.06) (k,cr ) (N,seis ) = (1.06) (909 psi) (1.00) = 964 psi
N ba = (a) (k,cr ) () (danchor ) (hef ) = (1.0) (964 psi) () (1 in.) (15 in.) = 36,342 lb
Nag =
1,360.4 in2
686.44 in2
hef = 15 in.
kcp = 2
Vcpg = (2) (74,212 lb) = 148,824 lb
Summary
Check sustained tension load
0.55 bond Nba N ua,s
bond = 0.65
Nba = 44,768 lb/anchor
Nua,s = 1,742 lb/anchor
(0.55) (0.65) (44,768 lb/anchor) = 16,005 lb/anchor > 1,742 lb/anchor
Anchors are ductile steel elements check D.3.3.4.3 (a) first
[Ductility check] Tension calculations per D.3.3.4.3 (a)
Tension
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
75,710 lb/anchor
90,852 lb/anchor
3,205 lb/anchor
3.53%
OK
Concrete breakout
54,991 lb
8,952 lb
16.30%
OK
Bond strength
47,880 lb
8,952 lb
18,70%
OK Controls
Steel strength does not control: D.3.3.4.3(a) is, therefore, not satisfied. Need to satisfy D.3.3.4.3(d)
Tension calculations per D.3.3.4.3 (d)
Tension
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
75,710 lb/anchor
steel = 0.75
56,783 lb/anchor
4,006 lb/anchor
7.05%
OK
Concrete breakout
54,991 lb
seismic = 0.75
concrete = 0.65
26,808 lb
11,190 lb
41.74%
OK
Bond strength
47,880 lb
seismic = 0.75
concrete = 0.65
23,342 lb
11,190 lb
47.94%
OK controls
Nominal strength
Design strength
Factored load
% Utilization
Comments
Steel strength
31,798 lb/anchor
steel = 0.65
20,669 lb/anchor
1,417 lb/anchor
6.86%
OK
Concrete breakout
23,907 lb
seismic = 0.75
concrete = 0.70
12,551 lb
8,500 lb
67.72%
OK controls
Pryout
148,824 lb
seismic = 0.75
concrete = 0.70
78,133 lb
8,500 lb
10.88%
OK
* While ICC-ES AC 308 is not harmonized with ACI 355.4, Hilti feels that designs according to ACI 318-11 Appendix D are appropriate.
48 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
ESR ref.*
D.7
Section 4.1.12
(0.2) Vcbg
Vua = 8,500 lb
Vua > (0.2) Vcbg
D.7.1
D.7.2
D.7.3
Eq. (D-42)
RD.7
* While ICC-ES AC 308 is not harmonized with ACI 355.4, Hilti feels that designs according to ACI 318-11 Appendix D are appropriate.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 49
Fastening Technology
3.1.11 D
esign of anchors
for fatigue
The design of structural elements to resist fatigue loading can
have a significant effect on the connection design. The reader
is referred to relevant standards for additional information on
this subject. Design of anchors for fatigue should consider the
following points:
1. The application of preload to prevent stress fluctuations
in the anchor rod element may be complicated by
gradual loss of preload over time, particularly in cases
where cracking in the base material may occur, and the
fact that many anchor designs do not provide sufficient
gauge length to permit the development of a meaningful
degree of preload strain.
2. Design of anchor groups for fatigue is often far more
critical than the design of a single anchor due to the
unequal distribution of loads. Load distribution is affected
by anchor slip as well as by the degree of annular gap
between the anchor and the baseplate and the specific
location of the anchor with respect to the hole in the
baseplate. It is therefore recommended that where
anchor groups are to be subjected to significant fatigue
loading, the annular gap between the anchors and
the baseplate be eliminated through the use of weld
washers, grout, or other means.
3. Secondary flexural stresses as generated by
eccentricities or gaps in the connection may be critical
to the fatigue behavior of the anchor.
50 Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Fastening Technology
post-installed
reinforcing bars
transverse
reinforcement
limits width of
splitting cracks
A
A
CIP
reinforcing
bars
forces
transferred
directly to CIP
reinforcing bars
via bond
Post-installed reinforcing for widening of a bridge deck
A distinction must be made between cases where the
reinforcing bar is designed in the same manner as a postinstalled adhesive anchor, i.e. using the principles of anchor
design as described in this document, and those instances
where the bar embedment length is established using the
principles of reinforcing, e.g. in accordance with ACI 318
Chapter 12. This distinction is generally made on the basis
of the specific geometry of the connection and whether the
anticipated concrete failure mode corresponds to one of
those considered in anchor design, e.g., concrete breakout,
pryout etc. as opposed to the splitting failure mode typically
associated with reinforcing bar design.
Section A-A
Post-installed reinforcement designed as a lap splice
For specific cases, please contact Hilti Technical Support
at 1-800-879-6000.
Hilti, Inc. (U.S.) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 51
Notes
52 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide
Anchoring Systems
What is creep?
Installation procedure
Bond strength
Temperature sensitivity
Creep resistance
Inspection requirements
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 53
54 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
HIT-HY 200
Base Material
Approvals
Drilling Method
Fastening Elements
Fast cure
**
41
to
104 F
30 min
12 hr
HIT-HY 100
Fast cure
5 min
30 hr
HIT-HY 70
41
to
104 F
41
to
104 F
Hohlbeton
23 to
104 F
Hohlbeton
4 min
Hohlbeton
1.5 hr
Hohlbeton
Kalksandstein
Kalksandstein
HIT-RE 500
41 to
104 F
Slow cure
30 min
12 hr
HIT-HY 10+
23
to
104 F
Fast cure
4 min
1.5 hr
Hohlbeton
Kalksandstein
32
to
104 F
Hohlbeton
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 55
Introducing SafeSetTM
Technology.
And a giant leap forward for your
next design.
Now you can design anchor rod and post-installed rebar connections with more
confidence. Inadequately cleaning holes during installation can reduce the
performance of conventional chemical anchor systems significantly. Hilti Safe Set
Technology eliminates this factor almost entirely in both cracked or uncracked
concrete and with anchor rods or post-installed rebar.
Hilti proudly presents the HIT-HY 200 System.
Rebar
Anchoring
3/8"
HIT-HY 200 and HIT-Z Rod
(no cleaning)
1/2"
5/8"
3/4"
7/8"
1"
1-1/4"
#7
#8
#9
SafeSet
SafeSet
SafeSet
#4
#5
#6
56 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
No cleaning required.
Set anchors and rebar reliably.
Its no secret that adhesive anchors encounter varying jobsite conditions. Hilti injection technology (HIT) is featured in
our lineup of quality products to combat this issue. With Hilti SafeSet Technology, which includes either Hollow Drill
Bits with the VC 20/40 Vacuum Cleaner or HIT-Z Anchor Rods, we are taking another giant leap forward by removing a
step of the installation process entirely.
Load [lb]
No hole cleaning
Displacement [in]
When a threaded rod or rebar is set with conventional
injection adhesive, the load its capable of taking may be very
low if the hole is inadequately cleaned after drilling. The Hilti
SafeSetsystem eliminates a cleaning step while still
providing excellent load values.
Load [lb]
Without hole
cleaning using the
Hilti HIT-Z Rod
With standard hole cleaning
or self-cleaning Hilti Hollow
Drill Bit
Displacement [in]
The new SafeSet System featuring HIT-HY 200 allows a
fastening point to take high loads, as though the hole were
cleaned using traditional installation methods.
TE-YD Hollow
Drill Bit
HIT-Z Rod
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 57
Product description
3.2.3.2
Material specifications
3.2.3.3
Technical data
3.2.3.4
Installation instructions
3.2.3.5
Ordering information
HIT-HY 200-A
HIT-HY 200-R
Listings/Approvals
ICC-ES (International code council)
ESR-3187
3.2.3.1 Product
description
Hilti HIT-HY 200 adhesive is an
injectable, two-component, hybrid
adhesive. The two components are
separated by means of a dual-cylinder
foil pack attached to a manifold. The
two components combine and react
when dispensed through a static mixing
nozzle attached to the manifold.
Hilti HIT-HY 200 adhesive is available in
two options, Hilti HIT-HY 200-A, and
Hilti HIT-HY 200-R. Both options utilize
the same technical data. Hilti
HIT-HY 200-A will have shorter working
times and curing times than Hilti
HIT-HY 200-R. The packaging for
each is different which helps the user
distinguish between the two adhesives.
Hilti HIT-HY 200 adhesive comes with
three hole cleaning options:
T
he traditional hole cleaning
method uses steel wire brushes
and compressed air
The self-cleaning method uses
the Hilti TE-CD or TE-YD Hollow
Drill Bits in conjunction with a Hilti
vacuum to remove the dust as you
drill. The hole is clean and ready
for anchor installation.
The no-cleaning method requires
the use of Hilti HIT-Z and HIT-Z-R
threaded anchor rods. If the base
material temperature is less than
41 F (5 C) or if diamond core
drilling is used, then the drilled hole
must be cleaned.
58 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.2.3
Uncracked
concrete
Dry
concrete
Cracked
concrete
Water-saturated
concrete
Water-filled
drilled holes
Permissible drilling
method
Permissible
concrete conditions
3.2.4
Effective
embedment
Minimum diameter
of fixture hole
Symbol
Units
do
in.
7/16
9/16
3/4
7/8
in.
(mm)
in.
(mm)
2-3/8
60
4-1/2
114
2-3/4
70
6
152
3-3/4
95
7-1/2
190
4
102
8-1/2
216
through-set
in.
1/2
5/8
13/161 15/161
preset
in.
7/16
9/16
11/16
13/16
ft-lb
(Nm)
15
(20)
30
(40)
60
(80)
110
(150)
minimum
hef,min
maximum
hef,max
Installation torque
Tinst
3.2.5
3.2.6
3.2.7
3.2.4
1 A
nchor may be installed in a hole drilled with a carbide-tipped bit without cleaning the drilling dust from the hole. Temperature must be 41 F or higher.
Drilling dust must be removed from the hole if the temperature is below 41 F. See Manufacturers Published Installation Instructions (MPII).
2 When temperatures are below 41 F, TE-CD or TE-YD Hollow Drill Bits used with a Hilti vacuum cleaner are viable methods for removing drilling dust from
the hole.
3 Holes drilled by diamond coring require cleaning with a wire brush, a water hose and compressed air. See MPII.
Setting information
3.2.4
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 59
Anchor length
Size
in.
(mm)
helix
Helix length
in.
(mm)
Smooth shank
length
in.
Total thread
length
(mm)
in.
(mm)
Usable thread
length
in.
(mm)
3/8 x 4-3/8
4-3/8
(111)
2-1/4
(57)
5/16
(8)
1-13/16
(46)
1-5/16
(33)
3/8 x 5-1/8
5-1/8
(130)
2-1/4
(57)
5/16
(8)
2-9/16
(65)
2-1/16
(52)
3/8 x 6-3/8
6-3/8
(162)
2-1/4
(57)
5/16
(8)
3-13/16
(97)
3-5/16
(84)
1/2 x 4-1/2
4-1/2
(114)
2-1/2
(63)
5/16
(8)
1-11/16
(43)
(26)
1/2 x 6-1/2
6-1/2
(165)
2-1/2
(63)
5/16
(8)
3-11/16
(94)
3-1/16
(77)
1/2 x 7-3/4
7-3/4
(197)
2-1/2
(63)
5/16
(8)
4-15/16
(126)
4-5/16
(109)
5/8 x 6
(152)
3-5/8
(92)
7/16
(11)
1-15/16
(49)
1-1/8
(28)
5/8 x 8
(203)
3-5/8
(92)
7/16
(11)
3-15/16
(100)
3-1/8
(79)
9-1/2
(241)
3-5/8
(92)
1-15/16
(49)
3-15/16
(100)
3-1/8
(79)
5/8 x 9-1/2
3/4 x 8-1/2
8-1/2
(216)
(102)
7/16
(12)
(102)
3-1/16
(77)
3/4 x 9-3/4
9-3/4
(248)
(102)
1-11/16
(44)
(102)
3-1/16
(77)
Figure 4 - HIT-TZ and HIT-TZ-R anchor rod length and thread dimension
60 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3/8
1/2
5/8
3/4
Tension Nn or Nr
Effective
embed.
in. (mm)
2-3/8
(60)
3-3/8
(86)
4-1/2
(114)
2-3/4
(70)
4-1/2
(114)
6
(152)
3-3/4
(95)
5-5/8
(143)
7-1/2
(191)
4
(102)
6-3/4
(171)
8-1/2
(216)
c = 2500 psi
(17.2 Mpa)
lb (kN)
2,855
(12.7)
4,835
(21.5)
5,560
(24.7)
3,555
(15.8)
7,445
(33.1)
8,190
(36.4)
5,665
(25.2)
10,405
(46.3)
14,950
(66.5)
6,240
(27.8)
13,680
(60.9)
19,330
(86.0)
c = 3000 psi
(20.7 Mpa)
lb (kN)
3,125
(13.9)
5,300
(23.6)
5,560
(24.7)
3,895
(17.3)
8,155
(36.3)
8,190
(36.4)
6,205
(27.6)
11,400
(50.7)
14,950
(66.5)
6,835
(30.4)
14,985
(66.7)
19,890
(88.5)
c = 4000 psi
(27.6 Mpa)
lb (kN)
3,610
(16.1)
5,560
(24.7)
5,560
(24.7)
4,500
(20.0)
8,190
(36.4)
8,190
(36.4)
7,165
(31.9)
13,165
(58.6)
14,950
(66.5)
7,895
(35.1)
17,305
(77.0)
19,890
(88.5)
Shear Vn or Vr
c = 6000 psi
(41.4 Mpa)
lb (kN)
4,425
(19.7)
5,560
(24.7)
5,560
(24.7)
5,510
(24.5)
8,190
(36.4)
8,190
(36.4)
8,775
(39.0)
14,950
(66.5)
14,950
(66.5)
9,665
(43.0)
19,890
(88.5)
19,890
(88.5)
c = 2500 psi
(17.2 Mpa)
lb (kN)
3,075
(13.7)
10,415
(46.3)
16,035
(71.3)
7,660
(34.1)
16,035
(71.3)
24,690
(109.8)
12,200
(54.3)
22,415
(99.7)
34,505
(153.5)
13,440
(59.8)
29,460
(131.0)
41,635
(185.2)
c = 3000 psi
(20.7 Mpa)
lb (kN)
3,370
(15.0)
11,410
(50.8)
17,570
(78.2)
8,395
(37.3)
17,570
(78.2)
27,045
(120.3)
13,365
(59.5)
24,550
(109.2)
37,800
(168.1)
14,725
(65.5)
32,275
(143.6)
45,605
(202.9)
c = 4000 psi
(27.6 Mpa)
lb (kN)
3,890
(17.3)
13,175
(58.6)
20,285
(90.2)
9,690
(43.1)
20,285
(90.2)
31,230
(138.9)
15,430
(68.6)
28,350
(126.1)
43,650
(194.2)
17,000
(75.6)
37,265
(165.8)
52,660
(234.2)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4,765
(21.2)
16,135
(71.8)
24,845
(110.5)
11,870
(52.8)
24,845
(110.5)
38,250
(170.1)
18,900
(84.1)
34,720
(154.4)
53,455
(237.8)
20,820
(92.6)
45,645
(203.0)
64,500
(286.9)
Table 4 - HIT-HY 200 design strength with concrete/pullout failure for HIT-Z(-R) rods in cracked concrete 1,2,3,4,5,6,7,8,9,10
Nominal
anchor
diameter
in.
3/8
1/2
5/8
3/4
Tension Nn or Nr
Effective
embed.
in. (mm)
2-3/8
(60)
3-3/8
(86)
4-1/2
(114)
2-3/4
(70)
4-1/2
(114)
6
(152)
3-3/4
(95)
5-5/8
(143)
7-1/2
(191)
4
(102)
6-3/4
(171)
8-1/2
(216)
c = 2500 psi
(17.2 Mpa)
lb (kN)
2,020
(9.0)
3,425
(15.2)
5,275
(23.5)
2,520
(11.2)
5,275
(23.5)
7,640
(34.0)
4,010
(17.8)
7,370
(32.8)
11,350
(50.5)
4,420
(19.7)
9,690
(43.1)
13,690
(60.9)
c = 3000 psi
(20.7 Mpa)
lb (kN)
2,215
(9.9)
3,755
(16.7)
5,560
(24.7)
2,760
(12.3)
5,780
(25.7)
7,640
(34.0)
4,395
(19.5)
8,075
(35.9)
12,430
(55.3)
4,840
(21.5)
10,615
(47.2)
15,000
(66.7)
c = 4000 psi
(27.6 Mpa)
lb (kN)
2,560
(11.4)
4,335
(19.3)
5,560
(24.7)
3,185
(14.2)
6,670
(29.7)
7,640
(34.0)
5,075
(22.6)
9,325
(41.5)
14,355
(63.9)
5,590
(24.9)
12,255
(54.5)
17,320
(77.0)
Shear Vn or Vr
c = 6000 psi
(41.4 Mpa)
lb (kN)
3,135
(13.9)
5,305
(23.6)
5,560
(24.7)
3,905
(17.4)
7,640
(34.0)
7,640
(34.0)
6,215
(27.6)
11,420
(50.8)
14,950
(66.5)
6,845
(30.4)
15,010
(66.8)
19,535
(86.9)
c = 2500 psi
(17.2 Mpa)
lb (kN)
2,180
(9.7)
7,380
(32.8)
11,360
(50.5)
5,425
(24.1)
11,360
(50.5)
17,490
(77.8)
8,640
(38.4)
15,875
(70.6)
24,440
(108.7)
9,520
(42.3)
20,870
(92.8)
29,490
(131.2)
c = 3000 psi
(20.7 Mpa)
lb (kN)
2,385
(10.6)
8,085
(36.0)
12,445
(55.4)
5,945
(26.4)
12,445
(55.4)
19,160
(85.2)
9,465
(42.1)
17,390
(77.4)
26,775
(119.1)
10,430
(46.4)
22,860
(101.7)
32,305
(143.7)
c = 4000 psi
(27.6 Mpa)
lb (kN)
2,755
(12.3)
9,335
(41.5)
14,370
(63.9)
6,865
(30.5)
14,370
(63.9)
22,120
(98.4)
10,930
(48.6)
20,080
(89.3)
30,915
(137.5)
12,040
(53.6)
26,395
(117.4)
37,300
(165.9)
c = 6000 psi
(41.4 Mpa)
lb (kN)
3,375
(15.0)
11,430
(50.8)
17,600
(78.3)
8,405
(37.4)
17,600
(78.3)
27,095
(120.5)
13,390
(59.6)
24,595
(109.4)
37,865
(168.4)
14,750
(65.6)
32,330
(143.8)
45,685
(203.2)
3.2.3
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
1
2
3
4
Shear4 Vsa
lb (kN)
4,750
(21.1)
8,695
(38.7)
13,850
(61.6)
20,455
(91.0)
1,930
(8.6)
3,530
(15.7)
5,625
(25.0)
8,310
(37.0)
Tensile3 Nsa
lb (kN)
Shear4 Vsa
lb (kN)
4,750
(21.1)
8,695
(38.7)
13,850
(61.6)
20,455
(91.0)
2,630
(11.7)
4,815
(21.4)
7,670
(34.1)
11,330
(50.4)
seis,V5
1.0
0.75
0.65
0.65
1 See section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements.
3 Tensile = Ase,N futa as noted in ACI 318 Appendix D.
4 Shear values determined by static shear tests with Vsa 0.60 Ase,V futa as noted in ACI 318 Appendix D.
5 Reduction factor for seismic shear only. See section 3.1.7.4 for additional information on seismic applications.
spacing s
Figure 6
Cmin,2
(smin,1 smin,2)
s smin,2 + ____________ (c cmin,2)
(cmin,1 cmin,2)
sdesign
smin at c
Cmin,1
Case 1
ca min at s
Smin,2
Smin,1
Concrete
Edge
cdesign
edge distance c
Table 6 - Minimum edge distance, spacing, and concrete thickness for 3/8-in. diameter Hilti HIT-Z and HIT-Z-R rods1
Nominal anchor diameter
Effective embedment
hef
Cracked concrete
Uncracked concrete
c min,1
c min,2
c min,1
c min,2
s min,1
s min,2
s min,1
s min,2
in.
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
3/8
3-3/8
(86)
2-3/8
(60)
22
4
(102)
3-1/8
(79)
9-1/8
(232)
5-5/8
(143)
1-7/8
(48)
2-1/8
(54)
6-3/8
(162)
3-5/8
(92)
1-7/8
(48)
1 or 2
4-5/8
(117)
2-3/4
(70)
7-3/4
(197)
4-3/4
(121)
1-7/8
(48)
1-7/8
(48)
5-1/2
(140)
3-1/8
(79)
1-7/8
(48)
5-3/4
(146)
2-1/4
(57)
6-1/8
(156)
3-3/4
(95)
1-7/8
(48)
1-7/8
(48)
4-1/4
(108)
2-3/8
(60)
1-7/8
(48)
22
4-5/8
(117)
2-3/4
(70)
7-3/4
(197)
4-3/4
(121)
1-7/8
(48)
1-7/8
(48)
5-1/2
(140)
3-1/8
(79)
1-7/8
(48)
4-1/2
(114)
1 or 2
5-5/8
(143)
2-1/4
(57)
6-1/2
(165)
3-7/8
(98)
1-7/8
(48)
1-7/8
(48)
3-1/2
(89)
2-1/2
(64)
1-7/8
(48)
6-3/8
(162)
2
(51)
5-5/8
(143)
3-1/4
(83)
1-7/8
(48)
1-7/8
(48)
2-5/8
(67)
2-1/8
(54)
1-7/8
(48)
22
5-3/4
(146)
2-1/4
(57)
6-1/8
(156)
3-3/4
(95)
1-7/8
(48)
1-7/8
(48)
3-1/4
(83)
2-3/8
(60)
1-7/8
(48)
1 or 2
6-3/4
(171)
1-7/8
(48)
5-3/8
(137)
3-1/8
(79)
1-7/8
(48)
1-7/8
(48)
2
(51)
2
(51)
1-7/8
(48)
7-3/8
(187)
1-7/8
(48)
4-1/2
(114)
2-3/4
(70)
1-7/8
(48)
1-7/8
(48)
1-7/8
(48)
1-7/8
(48)
1-7/8
(48)
Table 7 - Minimum edge distance, spacing, and concrete thickness for 1/2-in. diameter Hilti HIT-Z and HIT-Z-R rods1
d
Effective embedment
hef
Cracked Concrete
Uncracked Concrete
c min,1
c min,2
c min,1
c min,2
s min,1
s min,2
s min,1
s min,2
in.
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
1/2
4-1/2
(114)
2-3/4
(70)
22
4
(102)
5-1/8
(130)
14-7/8
(378)
9-1/4
(235)
2-1/2
(64)
3-5/8
(92)
10-7/8
(276)
6-1/2
(165)
2-1/2
(64)
1 or 2
5
(127)
4-1/8
(105)
11-7/8
(302)
7-1/4
(184)
2-1/2
(64)
3
(76)
8-1/2
(216)
5
(127)
2-1/2
(64)
7-1/8
(181)
2-7/8
(73)
8-5/8
(219)
4-7/8
(124)
2-1/2
(64)
2-1/2
(64)
6
(152)
3-1/4
(83)
2-1/2
(64)
22
5-3/4
(146)
3-5/8
(92)
10-1/4
(260)
6-1/4
(159)
2-1/2
(64)
2-5/8
(67)
7-3/8
(187)
4-1/4
(108)
2-1/2
(64)
6-3/4
(171)
3
(76)
9
(229)
5-1/4
(133)
2-1/2
(64)
2-1/2
(64)
5-1/2
(140)
3-1/2
(89)
2-1/2
(64)
8-1/4
(210)
2-1/2
(64)
7-1/4
(184)
4-1/8
(105)
2-1/2
(64)
2-1/2
(64)
3-1/8
(79)
2-3/4
(70)
2-1/2
(64)
22
7-1/4
(184)
2-7/8
(73)
8-1/8
(206)
4-3/4
(121)
2-1/2
(64)
2-1/2
(64)
4-1/2
(114)
3-1/4
(83)
2-1/2
(64)
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
6
(152)
1 or 2
3.2.3
3.2.7
1 or 2
8-1/4
(210)
2-1/2
(64)
7-1/4
(184)
4-1/8
(105)
2-1/2
(64)
2-1/2
(64)
3-1/8
(79)
2-3/4
(70)
2-1/2
(64)
9-3/4
(248)
2-1/2
(64)
5
(127)
3-3/8
(86)
2-1/2
(64)
2-1/2
(64)
2-1/2
(64)
2-1/2
(64)
2-1/2
(64)
3.2.8
1 L
inear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2
Linear interpoloation for a specific edge distance c, where cmin,1 < c < cmin,2, will determine the permissible spacing s as follows:
(smin,1 smin,2)
s smin,2 + ____________ (c cmin,2)
(cmin,1 cmin,2)
2 For shaded cells, drilling dust must be removed from drilled hole to justify minimum concrete thickness.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 63
d
hef
Cracked concrete
Uncracked concrete
Effective embedment
c min,1
c min,2
c min,1
c min,2
s min,1
s min,2
s min,1
s min,2
in.
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
5/8
5-5/8
(143)
3-3/4
(95)
22
5-1/2
(140)
6-1/4
(159)
18-3/8
(467)
11-3/8
(289)
3-1/8
(79)
4-5/8
(117)
13-7/8
(352)
8-1/4
(210)
3-1/8
(79)
1 or 2
7-3/4
9-3/8
(197)
(238)
4-1/2
3-3/4
(114)
(95)
12-7/8
10-5/8
(327)
(270)
7-3/4
6-1/4
(197)
(159)
3-1/8
3-1/8
(79)
(79)
3-3/8
3-1/8
(86)
(79)
9-1/2
8-3/4
(241)
(222)
5-1/2
4-3/8
(140)
(111)
3-1/8
3-1/8
(79)
(79)
22
7-3/8
(187)
4-5/8
(117)
13-7/8
(352)
8-1/4
(210)
3-1/8
(79)
3-1/2
(89)
10-1/8
(257)
5-7/8
(149)
3-1/8
(79)
1 or 2
9-5/8
10-1/2
(244)
(267)
3-5/8
3-1/4
(92)
(83)
10-3/8
9-3/4
(264)
(248)
6-1/8
5-1/2
(156)
(140)
3-1/8
3-1/8
(79)
(79)
3-1/8
3-1/8
(79)
(79)
6-1/2
5-3/8
(165)
(137)
4-1/4
3-7/8
(108)
(98)
3-1/8
3-1/8
(79)
(79)
7-1/2
(191)
22
9-1/4
(235)
3-3/4
(95)
10-7/8
(276)
6-3/8
(162)
3-1/8
(79)
3-1/8
(79)
7-1/8
(181)
4-1/2
(114)
3-1/8
(79)
1 or 2
11-1/2
12-1/4
(292)
(311)
3-1/8
3-1/8
(79)
(79)
8-3/8
7-3/8
(213)
(187)
4-7/8
4-5/8
(124)
(117)
3-1/8
3-1/8
(79)
(79)
3-1/8
3-1/8
(79)
(79)
3-7/8
3-1/8
(98)
(79)
3-3/8
3-1/8
(86)
(79)
3-1/8
3-1/8
(79)
(79)
Table 9 - Minimum edge distance, spacing, and concrete thickness for 3/4-in. diameter Hilti HIT-Z and HIT-Z-R rods1
Nominal anchor diameter
d
hef
Cracked concrete
Uncracked concrete
Effective embedment
c min,1
c min,2
c min,1
c min,2
s min,1
s min,2
s min,1
s min,2
in.
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
3/4
6-3/4
(171)
4
(102)
22
5-3/4
(146)
9-3/4
(248)
28-3/4
(730)
18-1/8
(460)
3-3/4
(95)
7-1/4
(184)
21-3/4
(552)
13-1/4
(337)
3-3/4
(95)
1 or 2
8
11-1/2
(203)
(292)
7
5
(178)
(127)
20-5/8
14
(524)
(356)
12-5/8
8-1/2
(321)
(216)
3-3/4
3-3/4
(95)
(95)
5-1/4
4-1/8
(133)
(105)
15-1/2
12-1/4
(394)
(311)
9-1/4
6
(235)
(152)
3-3/4
3-3/4
(95)
(95)
22
8-1/2
(216)
6-5/8
(168)
19-3/8
(492)
11-7/8
(302)
3-3/4
(95)
5
(127)
14-1/2
(368)
8-5/8
(219)
3-3/4
(95)
1 or 2
10-3/4
13-1/8
(273)
(333)
5-1/4
4-1/4
(133)
(108)
15-1/4
12-5/8
(387)
(321)
9-1/8
7-1/4
(232)
(184)
3-3/4
3-3/4
(95)
(95)
4
3-3/4
(102)
(95)
11-3/8
9
(289)
(229)
6-5/8
5-1/8
(168)
(130)
3-3/4
3-3/4
(95)
(95)
8-1/2
(216)
22
10-1/4
(260)
5-1/2
(140)
16
(406)
9-5/8
(244)
3-3/4
(95)
4-1/8
(105)
12-1/8
(308)
7
(178)
3-3/4
(95)
1 or 2
12-1/2
14-1/2
(318)
(368)
4-1/2
4
(114)
(102)
13-1/4
11
(337)
(279)
7-3/4
6-1/2
(197)
(165)
3-3/4
3-3/4
(95)
(95)
3-3/4
3-3/4
(95)
(95)
8-3/4
6-1/2
(222)
(165)
5-1/2
4-1/2
(140)
(114)
3-3/4
3-3/4
(95)
(95)
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2
Linear interpoloation for a specific edge distance c, where cmin,1 < c < cmin,2, will determine the permissible spacing s as follows:
(smin,1 smin,2)
s smin,2 + ____________ (c cmin,2)
(cmin,1 cmin,2)
2 For shaded cells, drilling dust must be removed from drilled hole to justify minimum concrete thickness.
64 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
1-7/8
2
2-1/4
3
4
4-5/8
5
5-3/4
6
7
8
9
10
11
12
14
16
18
24
30
36
> 48
Spacing factor in
tension
AN
in.
2-3/8
(mm)
(60)
(48)
0.63
(51)
0.64
(57)
0.66
(76)
0.71
(102) 0.78
(117) 0.82
(127) 0.85
(146) 0.90
(152) 0.92
(178) 0.99
(203) 1.00
(229) 1.00
(254) 1.00
(279)
(305)
(356)
(406)
(457)
(610)
(762)
(914)
(1219)
3-3/8
(86)
0.59
0.60
0.61
0.65
0.70
0.73
0.75
0.78
0.80
0.85
0.90
0.94
0.99
1.00
4-1/2
(114)
0.57
0.57
0.58
0.61
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.83
0.87
0.91
0.94
1.00
3-3/8
(86)
n/a
0.25
0.26
0.30
0.36
0.40
0.43
0.49
0.51
0.60
0.69
0.77
0.86
0.94
1.00
4-1/2
(114)
0.21
0.21
0.22
0.25
0.29
0.31
0.33
0.36
0.38
0.43
0.49
0.55
0.61
0.67
0.73
0.85
0.98
1.00
Spacing factor in
shear3
AV
2-3/8
(60)
0.57
0.57
0.58
0.61
0.64
0.66
0.68
0.70
0.71
0.75
0.79
0.82
0.86
0.89
0.93
1.00
3-3/8
(86)
0.53
0.53
0.54
0.55
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.65
0.66
0.68
0.70
0.73
0.76
0.79
0.89
0.99
1.00
4-1/2
(114)
0.52
0.52
0.53
0.54
0.55
0.56
0.56
0.57
0.57
0.59
0.60
0.61
0.62
0.63
0.65
0.67
0.70
0.72
0.79
0.87
0.94
1.00
To edge
RV
Toward edge
RV
2-3/8
(60)
n/a
n/a
0.33
0.51
0.79
0.98
1.00
1.00
1.00
3-3/8
(86)
n/a
0.09
0.10
0.16
0.24
0.30
0.34
0.42
0.45
0.57
0.69
0.83
0.97
1.00
4-1/2
(114)
0.05
0.06
0.07
0.10
0.16
0.20
0.22
0.27
0.29
0.37
0.45
0.54
0.63
0.72
0.83
1.00
2-3/8
(60)
n/a
n/a
0.38
0.51
0.79
0.98
1.00
1.00
1.00
3-3/8
(86)
n/a
0.17
0.21
0.32
0.44
0.49
0.52
0.59
0.62
0.72
0.83
0.93
1.00
Concrete thickness
factor in shear4
HV
4-1/2
(114)
0.10
0.11
0.13
0.21
0.29
0.31
0.33
0.36
0.38
0.43
0.49
0.55
0.63
0.72
0.83
1.00
2-3/8
(60)
n/a
n/a
n/a
n/a
0.76
0.81
0.84
0.91
0.92
1.00
1.00
3-3/8
(86)
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.61
0.63
0.68
0.72
0.77
0.81
0.85
0.88
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.53
0.54
0.58
0.63
0.66
0.70
0.73
0.77
0.83
0.88
0.94
1.00
3.2.4
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
1-7/8
2
2-1/4
3
4
4-5/8
5
5-3/4
6
7
8
9
10
11
12
14
16
18
24
30
36
> 48
Spacing factor in
tension
AN
in.
2-3/8
(mm)
(60)
(48)
0.63
(51)
0.64
(57)
0.66
(76)
0.71
(102) 0.78
(117) 0.82
(127) 0.85
(146) 0.90
(152) 0.92
(178) 0.99
(203) 1.00
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(610)
(762)
(914)
(1219)
3-3/8
(86)
0.59
0.60
0.61
0.65
0.70
0.73
0.75
0.78
0.80
0.85
0.90
0.94
0.99
1.00
4-1/2
(114)
0.57
0.57
0.58
0.61
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.83
0.87
0.91
0.94
1.00
3-3/8
(86)
0.56
0.57
0.60
0.70
0.84
0.93
0.99
1.00
4-1/2
(114)
0.50
0.51
0.53
0.60
0.70
0.76
0.80
0.88
0.91
1.00
Spacing factor in
shear3
AV
2-3/8
(60)
0.57
0.57
0.58
0.61
0.64
0.67
0.68
0.71
0.71
0.75
0.79
0.82
0.86
0.89
0.93
1.00
3-3/8
(86)
0.53
0.53
0.54
0.55
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.65
0.66
0.68
0.70
0.73
0.76
0.79
0.89
0.99
1.00
4-1/2
(114)
0.52
0.52
0.53
0.54
0.55
0.56
0.56
0.57
0.57
0.59
0.60
0.61
0.62
0.64
0.65
0.67
0.70
0.72
0.79
0.87
0.94
1.00
3.2.4
3.2.4
Table 11 - Load adjustment factors for 3/8-in. diameter HIT-Z and HIT-Z-R rods in cracked concrete 1,2
3/8-in. HIT-Z(-R)
cracked concrete
3.2.3
To edge
RV
Toward edge
RV
2-3/8
(60)
n/a
n/a
0.34
0.52
0.80
0.99
1.00
3-3/8
(86)
0.08
0.09
0.10
0.16
0.25
0.31
0.34
0.42
0.45
0.57
0.70
0.83
0.97
1.00
4-1/2
(114)
0.05
0.06
0.07
0.10
0.16
0.20
0.22
0.28
0.29
0.37
0.45
0.54
0.63
0.73
0.83
1.00
2-3/8
(60)
n/a
n/a
0.67
0.88
1.00
3-3/8
(86)
0.16
0.17
0.21
0.32
0.49
0.61
0.69
0.85
0.91
1.00
Concrete thickness
factor in shear4
HV
4-1/2
(114)
0.10
0.11
0.14
0.21
0.32
0.40
0.45
0.55
0.59
0.74
0.91
1.00
2-3/8
(60)
n/a
n/a
n/a
n/a
0.76
0.81
0.85
0.91
0.93
1.00
3-3/8
(86)
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.61
0.63
0.68
0.72
0.77
0.81
0.85
0.89
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.53
0.54
0.59
0.63
0.67
0.70
0.74
0.77
0.83
0.89
0.94
1.00
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 65
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
2-1/2
2-7/8
3
3-1/2
4
4-1/2
5
5-1/2
6
7
7-1/4
8
9
10
11
12
14
16
18
24
30
36
> 48
Spacing factor in
tension
AN
2-3/4
in.
(70)
(mm)
(64)
0.65
(73)
0.67
(76)
0.68
(89)
0.71
(102) 0.74
(114) 0.77
(127) 0.80
(140) 0.83
(152) 0.86
(178) 0.92
(184) 0.94
(203) 0.98
(229) 1.00
(254) 1.00
(279) 1.00
(305) 1.00
(356) 1.00
(406) 1.00
(457)
(610)
(762)
(914)
(1219)
4-1/2
(114)
0.59
0.61
0.61
0.63
0.65
0.67
0.69
0.70
0.72
0.76
0.77
0.80
0.83
0.87
0.91
0.94
1.00
6
(152)
0.57
0.58
0.58
0.60
0.61
0.63
0.64
0.65
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
4-1/2
(114)
0.23
0.24
0.25
0.27
0.29
0.31
0.33
0.35
0.38
0.43
0.44
0.49
0.55
0.61
0.67
0.73
0.85
0.98
1.00
6
(152)
0.20
0.21
0.21
0.22
0.24
0.25
0.27
0.28
0.30
0.33
0.34
0.36
0.40
0.44
0.48
0.53
0.62
0.70
0.79
1.00
Spacing factor in
shear3
AV
2-3/4
(70)
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.62
0.63
0.65
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.88
1.00
4-1/2
(114)
0.53
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.72
0.74
0.82
0.90
0.98
1.00
6
(152)
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.68
0.74
0.80
0.86
0.98
To edge
RV
Toward edge
RV
2-3/4
(70)
n/a
0.22
0.23
0.29
0.36
0.42
0.50
0.57
0.65
0.82
0.87
1.00
1.00
1.00
4-1/2
(114)
0.09
0.11
0.12
0.15
0.18
0.22
0.26
0.30
0.34
0.42
0.45
0.52
0.62
0.72
0.84
0.95
1.00
6
(152)
0.06
0.07
0.08
0.10
0.12
0.14
0.17
0.19
0.22
0.28
0.29
0.34
0.40
0.47
0.54
0.62
0.78
0.95
1.00
2-3/4
(70)
n/a
0.35
0.36
0.40
0.44
0.50
0.55
0.61
0.66
0.82
0.87
1.00
1.00
1.00
4-1/2
(114)
0.18
0.22
0.24
0.30
0.33
0.35
0.38
0.40
0.43
0.49
0.50
0.56
0.63
0.72
0.84
0.95
1.00
Concrete thickness
factor in shear4
HV
6
(152)
0.12
0.15
0.15
0.19
0.24
0.25
0.27
0.28
0.30
0.33
0.34
0.36
0.40
0.47
0.54
0.62
0.78
0.95
1.00
2-3/4
(70)
n/a
n/a
n/a
n/a
0.58
0.61
0.65
0.68
0.71
0.77
0.78
0.82
0.87
0.92
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.61
0.62
0.66
0.70
0.73
0.77
0.80
0.87
0.93
0.98
1.00
6
(152)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.57
0.60
0.64
0.67
0.70
0.75
0.80
0.85
0.98
1.00
Table 13 - Load adjustment factors for 1/2-in. diameter HIT-Z and HIT-Z-R rods in Cracked Concrete 1,2
Edge distance in shear
1/2-in. HIT-Z(-R)
cracked concrete
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
2-1/2
2-7/8
3
3-1/2
4
4-1/2
5
5-1/2
6
7
7-1/4
8
9
10
11
12
14
16
18
24
30
36
> 48
Spacing factor in
tension
AN
2-3/4
in.
(70)
(mm)
(64)
0.65
(73)
0.67
(76)
0.68
(89)
0.71
(102) 0.74
(114) 0.77
(127) 0.80
(140) 0.83
(152) 0.86
(178) 0.92
(184) 0.94
(203) 0.98
(229) 1.00
(254) 1.00
(279) 1.00
(305)
(356)
(406)
(457)
(610)
(762)
(914)
(1219)
4-1/2
(114)
0.59
0.61
0.61
0.63
0.65
0.67
0.69
0.70
0.72
0.76
0.77
0.80
0.83
0.87
0.91
0.94
1.00
6
(152)
0.57
0.58
0.58
0.60
0.61
0.63
0.64
0.65
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
4-1/2
(114)
0.56
0.59
0.60
0.65
0.70
0.75
0.80
0.86
0.91
1.00
6
(152)
0.50
0.53
0.53
0.57
0.60
0.64
0.67
0.71
0.75
0.83
0.85
0.91
1.00
Spacing factor in
shear3
AV
2-3/4
(70)
0.55
0.56
0.56
0.57
0.58
0.59
0.61
0.62
0.63
0.65
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.84
0.88
1.00
4-1/2
(114)
0.53
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.65
0.66
0.69
0.72
0.74
0.82
0.91
0.99
1.00
6
(152)
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.68
0.74
0.80
0.87
0.99
To edge
RV
Toward edge
RV
2-3/4
(70)
0.18
0.22
0.23
0.29
0.36
0.43
0.50
0.58
0.66
0.83
0.88
1.00
4-1/2
(114)
0.09
0.11
0.12
0.15
0.18
0.22
0.26
0.30
0.34
0.43
0.45
0.52
0.62
0.73
0.84
0.96
1.00
6
(152)
0.06
0.07
0.08
0.10
0.12
0.14
0.17
0.19
0.22
0.28
0.29
0.34
0.41
0.47
0.55
0.62
0.79
0.96
1.00
2-3/4
(70)
0.35
0.44
0.47
0.59
0.72
0.86
1.00
1.00
1.00
1.00
4-1/2
(114)
0.18
0.23
0.24
0.30
0.37
0.44
0.52
0.60
0.68
0.86
0.90
1.00
Concrete thickness
factor in shear4
HV
6
(152)
0.12
0.15
0.16
0.20
0.24
0.29
0.34
0.39
0.44
0.56
0.59
0.68
0.81
0.95
1.00
2-3/4
(70)
n/a
n/a
n/a
n/a
0.58
0.62
0.65
0.68
0.71
0.77
0.78
0.82
0.87
0.92
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.62
0.63
0.66
0.70
0.74
0.77
0.81
0.87
0.93
0.99
1.00
6
(152)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.57
0.60
0.64
0.67
0.70
0.75
0.81
0.85
0.99
1.00
66 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
3-1/8
3-1/4
3-3/4
4
5
5-1/2
6
7
7-3/8
8
9
9-1/4
10
11
12
14
16
18
24
30
36
> 48
Spacing factor in
tension
AN
in.
3-3/4
(mm)
(95)
(79)
0.64
(83)
0.64
(95)
0.67
(102) 0.68
(127) 0.72
(140) 0.74
(152) 0.77
(178) 0.81
(187) 0.83
(203) 0.86
(229) 0.90
(235) 0.91
(254) 0.94
(279) 0.99
(305) 1.00
(356) 1.00
(406) 1.00
(457) 1.00
(610) 1.00
(762)
(914)
(1219)
5-5/8
(143)
0.59
0.60
0.61
0.62
0.65
0.66
0.68
0.71
0.72
0.74
0.77
0.77
0.80
0.83
0.86
0.91
0.97
1.00
7-1/2
(191)
0.57
0.57
0.58
0.59
0.61
0.62
0.63
0.66
0.66
0.68
0.70
0.71
0.72
0.74
0.77
0.81
0.86
0.90
1.00
5-5/8
(143)
n/a
0.24
0.25
0.26
0.29
0.31
0.33
0.36
0.38
0.40
0.45
0.46
0.50
0.55
0.60
0.70
0.80
0.89
1.00
7-1/2
(191)
0.20
0.20
0.21
0.22
0.24
0.25
0.26
0.29
0.30
0.31
0.34
0.35
0.37
0.39
0.43
0.50
0.57
0.64
0.86
1.00
Spacing factor in
shear3
AV
3-3/4
(95)
0.55
0.55
0.56
0.57
0.58
0.59
0.60
0.62
0.62
0.63
0.65
0.65
0.67
0.68
0.70
0.73
0.77
0.80
0.90
1.00
5-5/8
(143)
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.69
0.71
0.78
0.85
0.92
1.00
7-1/2
(191)
0.53
0.53
0.53
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.60
0.60
0.62
0.64
0.66
0.71
0.76
0.81
0.92
To edge
RV
Toward edge
RV
3-3/4
(95)
n/a
n/a
0.23
0.25
0.36
0.41
0.47
0.59
0.64
0.72
0.86
0.89
1.00
1.00
1.00
5-5/8
(143)
n/a
0.11
0.13
0.15
0.21
0.24
0.27
0.34
0.37
0.41
0.50
0.52
0.58
0.67
0.76
0.96
1.00
7-1/2
(191)
0.07
0.07
0.09
0.10
0.13
0.15
0.18
0.22
0.24
0.27
0.32
0.34
0.38
0.43
0.50
0.62
0.76
0.91
1.00
3-3/4
(95)
n/a
n/a
0.34
0.36
0.42
0.45
0.49
0.59
0.64
0.72
0.86
0.89
1.00
1.00
1.00
5-5/8
(143)
n/a
0.21
0.27
0.29
0.38
0.40
0.42
0.47
0.49
0.52
0.58
0.59
0.64
0.70
0.77
0.96
1.00
Concrete thickness
factor in shear4
HV
7-1/2
(191)
0.13
0.14
0.17
0.19
0.24
0.25
0.26
0.29
0.30
0.31
0.34
0.35
0.38
0.43
0.50
0.62
0.76
0.91
1.00
3-3/4
(95)
n/a
n/a
n/a
n/a
n/a
0.61
0.63
0.68
0.70
0.73
0.78
0.79
0.82
0.86
0.90
0.97
1.00
5-5/8
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.65
0.65
0.68
0.71
0.75
0.81
0.86
0.91
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.62
0.65
0.70
0.75
0.79
0.91
1.00
Table 15 - Load adjustment factors for 5/8-in. diameter HIT-Z and HIT-Z-R rods in cracked concrete 1,2
Spacing (s) / Edge Distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
3-1/8
3-1/4
3-3/4
4
5
5-1/2
6
7
7-3/8
8
9
9-1/4
10
11
12
14
16
18
24
30
36
> 48
Spacing factor in
tension
AN
3-3/4
in.
(95)
(mm)
(79)
0.64
(83)
0.64
(95)
0.67
(102) 0.68
(127) 0.72
(140) 0.74
(152) 0.77
(178) 0.81
(187) 0.83
(203) 0.86
(229) 0.90
(235) 0.91
(254) 0.94
(279) 0.99
(305) 1.00
(356) 1.00
(406)
(457)
(610)
(762)
(914)
(1219)
5-5/8
(143)
0.59
0.60
0.61
0.62
0.65
0.66
0.68
0.71
0.72
0.74
0.77
0.77
0.80
0.83
0.86
0.91
0.97
1.00
7-1/2
(191)
0.57
0.57
0.58
0.59
0.61
0.62
0.63
0.66
0.66
0.68
0.70
0.71
0.72
0.74
0.77
0.81
0.86
0.90
1.00
5-5/8
(143)
0.56
0.56
0.60
0.62
0.70
0.74
0.78
0.87
0.90
0.96
1.00
7-1/2
(191)
0.50
0.51
0.53
0.55
0.60
0.63
0.66
0.72
0.74
0.78
0.85
0.86
0.91
0.98
1.00
Spacing factor in
shear3
AV
3-3/4
(95)
0.55
0.55
0.56
0.57
0.58
0.59
0.60
0.62
0.62
0.63
0.65
0.66
0.67
0.69
0.70
0.74
0.77
0.80
0.90
1.00
5-5/8
(143)
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.69
0.71
0.78
0.85
0.92
1.00
7-1/2
(191)
0.53
0.53
0.53
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.60
0.60
0.62
0.64
0.66
0.71
0.76
0.81
0.92
To edge
RV
Toward edge
RV
3-3/4
(95)
0.18
0.19
0.23
0.26
0.36
0.41
0.47
0.59
0.64
0.73
0.87
0.90
1.00
5-5/8
(143)
0.10
0.11
0.13
0.15
0.21
0.24
0.27
0.34
0.37
0.42
0.50
0.52
0.58
0.67
0.77
0.97
1.00
7-1/2
(191)
0.07
0.07
0.09
0.10
0.13
0.15
0.18
0.22
0.24
0.27
0.32
0.34
0.38
0.44
0.50
0.63
0.77
0.92
1.00
3-3/4
(95)
0.35
0.38
0.47
0.51
0.72
0.83
0.94
1.00
1.00
1.00
1.00
5-5/8
(143)
0.20
0.22
0.27
0.30
0.41
0.48
0.54
0.68
0.74
0.84
1.00
Concrete thickness
factor in shear4
HV
7-1/2
(191)
0.13
0.14
0.17
0.19
0.27
0.31
0.35
0.44
0.48
0.54
0.65
0.68
0.76
0.88
1.00
1.00
3.2.4
3.2.4
3.2.4
3.2.3
3-3/4
(95)
n/a
n/a
n/a
n/a
n/a
0.61
0.64
0.69
0.70
0.73
0.78
0.79
0.82
0.86
0.90
0.97
1.00
5-5/8
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.65
0.66
0.68
0.72
0.75
0.81
0.86
0.92
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.62
0.65
0.70
0.75
0.79
0.92
1.00
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 67
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
3-3/4
4
4-1/8
4-1/4
5
5-3/4
6
7
8
8-1/2
9
10
10-1/4
11
12
14
16
18
24
30
36
> 48
in.
(mm)
(95)
(102)
(105)
(108)
(127)
(146)
(152)
(178)
(203)
(216)
(229)
(254)
(260)
(279)
(305)
(356)
(406)
(457)
(610)
(762)
(914)
(1219)
Spacing factor in
tension
AN
4
(102)
0.66
0.67
0.67
0.68
0.71
0.74
0.75
0.79
0.83
0.85
0.88
0.92
0.93
0.96
1.00
1.00
1.00
1.00
1.00
1.00
6-3/4
(171)
0.59
0.60
0.60
0.60
0.62
0.64
0.65
0.67
0.70
0.71
0.72
0.75
0.75
0.77
0.80
0.85
0.90
0.94
1.00
8-1/2
(216)
0.57
0.58
0.58
0.58
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.70
0.70
0.72
0.74
0.77
0.81
0.85
0.97
1.00
6-3/4
(171)
n/a
n/a
n/a
0.24
0.26
0.28
0.28
0.31
0.34
0.36
0.37
0.40
0.41
0.44
0.48
0.56
0.64
0.72
0.97
1.00
8-1/2
(216)
n/a
0.21
0.21
0.21
0.23
0.24
0.24
0.27
0.29
0.30
0.31
0.33
0.34
0.35
0.38
0.43
0.50
0.56
0.75
0.93
1.00
Spacing factor in
shear3
AV
4
(102)
0.56
0.57
0.57
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.70
0.73
0.76
0.80
0.89
0.99
1.00
6-3/4
(171)
0.54
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.68
0.74
0.80
0.86
0.99
8-1/2
(216)
0.53
0.53
0.53
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.64
0.69
0.74
0.79
0.89
To edge
RV
Toward edge
RV
4
(102)
n/a
n/a
n/a
n/a
0.35
0.43
0.45
0.57
0.70
0.77
0.83
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
6-3/4
(171)
n/a
n/a
n/a
0.13
0.17
0.21
0.22
0.28
0.34
0.37
0.40
0.47
0.49
0.55
0.62
0.78
0.96
1.00
8-1/2
(216)
n/a
0.08
0.09
0.09
0.12
0.15
0.16
0.20
0.24
0.26
0.29
0.33
0.35
0.39
0.44
0.55
0.68
0.81
1.00
4
(102)
n/a
n/a
n/a
n/a
0.39
0.44
0.45
0.57
0.70
0.77
0.83
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
6-3/4
(171)
n/a
n/a
n/a
0.26
0.32
0.34
0.35
0.38
0.42
0.44
0.45
0.49
0.50
0.55
0.62
0.78
0.96
1.00
Concrete thickness
factor in shear4
HV
8-1/2
(216)
n/a
0.17
0.18
0.19
0.23
0.24
0.24
0.27
0.29
0.30
0.31
0.33
0.35
0.39
0.44
0.55
0.68
0.81
1.00
4
(102)
n/a
n/a
n/a
n/a
n/a
0.61
0.63
0.68
0.72
0.75
0.77
0.81
0.82
0.85
0.89
0.96
1.00
6-3/4
(171)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.60
0.64
0.64
0.67
0.70
0.75
0.80
0.85
0.99
1.00
8-1/2
(216)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.62
0.67
0.72
0.76
0.88
0.98
1.00
Table 17 - Load adjustment factors for 3/4-in. diameter HIT-Z and HIT-Z-R rods in cracked concrete 1,2
Edge distance in shear
3/4-in. HIT-Z(-R)
cracked concrete
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
3-3/4
4
4-1/8
4-1/4
5
5-3/4
6
7
8
8-1/2
9
10
10-1/4
11
12
14
16
18
24
30
36
>48
in.
(mm)
(95)
(102)
(105)
(108)
(127)
(146)
(152)
(178)
(203)
(216)
(229)
(254)
(260)
(279)
(305)
(356)
(406)
(457)
(610)
(762)
(914)
(1219)
Spacing factor in
tension
AN
4
(102)
0.66
0.67
0.67
0.68
0.71
0.74
0.75
0.79
0.83
0.85
0.88
0.92
0.93
0.96
1.00
1.00
1.00
1.00
1.00
6-3/4
(171)
0.59
0.60
0.60
0.60
0.62
0.64
0.65
0.67
0.70
0.71
0.72
0.75
0.75
0.77
0.80
0.85
0.90
0.94
1.00
8-1/2
(216)
0.57
0.58
0.58
0.58
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.70
0.70
0.72
0.74
0.77
0.81
0.85
0.97
1.00
6-3/4
(171)
0.56
0.57
0.58
0.59
0.63
0.68
0.70
0.77
0.84
0.88
0.91
0.99
1.00
8-1/2
(216)
0.51
0.52
0.53
0.53
0.57
0.61
0.62
0.67
0.72
0.75
0.78
0.83
0.85
0.89
0.95
1.00
Spacing factor in
shear3
AV
4
(102)
0.56
0.57
0.57
0.57
0.58
0.59
0.60
0.62
0.63
0.64
0.65
0.67
0.67
0.68
0.70
0.73
0.76
0.80
0.90
1.00
1.00
6-3/4
(171)
0.54
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.68
0.74
0.81
0.87
0.99
8-1/2
(216)
0.53
0.53
0.53
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.65
0.69
0.74
0.79
0.89
To edge
RV
Toward edge
RV
4
(102)
n/a
n/a
0.26
0.27
0.35
0.43
0.46
0.58
0.70
0.77
0.84
0.99
1.00
1.00
1.00
1.00
6-3/4
(171)
0.11
0.12
0.13
0.13
0.17
0.21
0.22
0.28
0.34
0.37
0.41
0.48
0.50
0.55
0.63
0.79
0.97
1.00
8-1/2
(216)
0.08
0.09
0.09
0.09
0.12
0.15
0.16
0.20
0.24
0.26
0.29
0.34
0.35
0.39
0.44
0.56
0.68
0.82
1.00
4
(102)
n/a
n/a
0.52
0.55
0.70
0.86
0.92
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
6-3/4
(171)
0.22
0.24
0.25
0.26
0.34
0.42
0.44
0.56
0.68
0.75
0.82
0.95
0.99
1.00
Concrete thickness
factor in shear4
HV
8-1/2
(216)
0.16
0.17
0.18
0.19
0.24
0.29
0.31
0.40
0.48
0.53
0.58
0.68
0.70
0.78
0.89
1.00
4
(102)
n/a
n/a
n/a
n/a
n/a
0.62
0.63
0.68
0.73
0.75
0.77
0.81
0.82
0.85
0.89
0.96
1.00
6-3/4
(171)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.64
0.65
0.67
0.70
0.76
0.81
0.86
0.99
1.00
8-1/2
(216)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.60
0.62
0.67
0.72
0.76
0.88
0.98
1.00
68 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Uncracked
concrete
Dry
concrete
Cracked
concrete
Water-saturated
concrete
Permissible
drilling
method
Permissible
concrete
conditions
3.2.3
3.2.4
3.2.4
Effective
embedment
Symbol
Units
do
hef,std
minimum
hef,min
maximum
hef,max
hmin
Rebar size
3
10
in.
1/2
5/8
3/4
7/8
1-1/8
1-3/8
1-1/2
in.
3-3/8
4-1/2
5-5/8
6-3/4
7-7/8
(mm)
(86)
(114)
(143)
(171)
(200)
(229)
(257)
10-1/8 11-1/4
(286)
in.
2-3/8
2-3/4
3-1/8
3-1/2
3-1/2
4-1/2
(mm)
(60)
(70)
(79)
(89)
(89)
(102)
(114)
(127)
in.
7-1/2
10
12-1/2
15
17-1/2
20
22-1/2
25
(mm)
(191)
(254)
(318)
(381)
(445)
(508)
(572)
(635)
in.
hef + 1-1/4
(mm)
hef + 30
hef + 2do
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 69
Rebar size
#3
#4
#5
#6
#7
#8
#9
#10
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
3-3/8
(86)
4-1/2
(114)
7-1/2
(191)
4-1/2
(114)
6
(152)
10
(254)
5-5/8
(143)
7-1/2
(191)
12-1/2
(318)
6-3/4
(171)
9
(229)
15
(381)
7-7/8
(200)
10-1/2
(267)
17-1/2
(445)
9
(229)
12
(305)
20
(508)
10-1/8
(257)
13-1/2
(343)
22-1/2
(572)
11-1/4
(286)
15
(381)
25
(635)
4,295
(19.1)
5,725
(25.5)
9,540
(42.4)
7,445
(33.1)
10,175
(45.3)
16,960
(75.4)
10,405
(46.3)
15,900
(70.7)
26,500
(117.9)
13,680
(60.9)
21,060
(93.7)
38,160
(169.7)
17,235
(76.7)
26,540
(118.1)
51,935
(231.0)
21,060
(93.7)
32,425
(144.2)
67,835
(301.7)
25,130
(111.8)
38,690
(172.1)
83,245
(370.3)
29,430
(130.9)
45,315
(201.6)
97,500
(433.7)
4,295
(19.1)
5,725
(25.5)
9,540
(42.4)
7,630
(33.9)
10,175
(45.3)
16,960
(75.4)
11,400
(50.7)
15,900
(70.7)
26,500
(117.9)
14,985
(66.7)
22,895
(101.8)
38,160
(169.7)
18,885
(84.0)
29,070
(129.3)
51,935
(231.0)
23,070
(102.6)
35,520
(158.0)
67,835
(301.7)
27,530
(122.5)
42,380
(188.5)
85,855
(381.9)
32,240
(143.4)
49,640
(220.8)
105,995
(471.5)
4,295
(19.1)
5,725
(25.5)
9,540
(42.4)
7,630
(33.9)
10,175
(45.3)
16,960
(75.4)
11,925
(53.0)
15,900
(70.7)
26,500
(117.9)
17,170
(76.4)
22,895
(101.8)
38,160
(169.7)
21,805
(97.0)
31,160
(138.6)
51,935
(231.0)
26,640
(118.5)
40,700
(181.0)
67,835
(301.7)
31,785
(141.4)
48,940
(217.7)
85,855
(381.9)
37,230
(165.6)
57,320
(255.0)
105,995
(471.5)
4,550
(20.2)
6,065
(27.0)
10,110
(45.0)
8,090
(36.0)
10,785
(48.0)
17,975
(80.0)
12,640
(56.2)
16,855
(75.0)
28,090
(124.9)
18,200
(81.0)
24,270
(108.0)
40,445
(179.9)
24,775
(110.2)
33,030
(146.9)
55,055
(244.9)
32,360
(143.9)
43,145
(191.9)
71,905
(319.8)
38,930
(173.2)
54,605
(242.9)
91,005
(404.8)
45,595
(202.8)
67,410
(299.9)
112,355
(499.8)
9,245
(41.1)
12,330
(54.8)
20,545
(91.4)
16,035
(71.3)
21,915
(97.5)
36,525
(162.5)
22,415
(99.7)
34,245
(152.3)
57,075
(253.9)
29,460
(131.0)
45,360
(201.8)
82,185
(365.6)
37,125
(165.1)
57,160
(254.3)
111,865
(497.6)
45,360
(201.8)
69,835
(310.6)
146,110
(649.9)
54,125
(240.8)
83,330
(370.7)
179,300
(797.6)
63,395
(282.0)
97,600
(434.1)
210,000
(934.1)
9,245
(41.1)
12,330
(54.8)
20,545
(91.4)
16,435
(73.1)
21,915
(97.5)
36,525
(162.5)
24,550
(109.2)
34,245
(152.3)
57,075
(253.9)
32,275
(143.6)
49,310
(219.3)
82,185
(365.6)
40,670
(180.9)
62,615
(278.5)
111,865
(497.6)
49,690
(221.0)
76,500
(340.3)
146,110
(649.9)
59,290
(263.7)
91,285
(406.1)
184,920
(822.6)
69,445
(308.9)
106,915
(475.6)
228,295
(1015.5)
9,245
(41.1)
12,330
(54.8)
20,545
(91.4)
16,435
(73.1)
21,915
(97.5)
36,525
(162.5)
25,685
(114.3)
34,245
(152.3)
57,075
(253.9)
36,985
(164.5)
49,310
(219.3)
82,185
(365.6)
46,960
(208.9)
67,120
(298.6)
111,865
(497.6)
57,375
(255.2)
87,665
(390.0)
146,110
(649.9)
68,465
(304.5)
105,405
(468.9)
184,920
(822.6)
80,185
(356.7)
123,455
(549.2)
228,295
(1015.5)
9,800
(43.6)
13,070
(58.1)
21,780
(96.9)
17,425
(77.5)
23,230
(103.3)
38,720
(172.2)
27,225
(121.1)
36,300
(161.5)
60,500
(269.1)
39,205
(174.4)
52,270
(232.5)
87,120
(387.5)
53,360
(237.4)
71,145
(316.5)
118,575
(527.4)
69,695
(310.0)
92,925
(413.3)
154,875
(688.9)
83,850
(373.0)
117,610
(523.2)
196,015
(871.9)
98,205
(436.8)
145,195
(645.9)
241,995
(1076.4)
1
2
3
4
70 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Rebar size
#3
#4
#5
#6
#7
#8
#9
#10
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
3-3/8
(86)
4-1/2
(114)
7-1/2
(191)
4-1/2
(114)
6
(152)
10
(254)
5-5/8
(143)
7-1/2
(191)
12-1/2
(318)
6-3/4
(171)
9
(229)
15
(381)
7-7/8
(200)
10-1/2
(267)
17-1/2
(445)
9
(229)
12
(305)
20
(508)
10-1/8
(257)
13-1/2
(343)
22-1/2
(572)
11-1/4
(286)
15
(381)
25
(635)
2,700
(12.0)
3,600
(16.0)
5,995
(26.7)
4,830
(21.5)
6,440
(28.6)
10,730
(47.7)
7,370
(32.8)
10,120
(45.0)
16,865
(75.0)
9,690
(43.1)
14,640
(65.1)
24,395
(108.5)
12,210
(54.3)
16,885
(75.1)
28,140
(125.2)
14,920
(66.4)
22,150
(98.5)
36,920
(164.2)
17,800
(79.2)
27,405
(121.9)
46,935
(208.8)
20,850
(92.7)
32,095
(142.8)
58,070
(258.3)
2,700
(12.0)
3,600
(16.0)
5,995
(26.7)
4,830
(21.5)
6,440
(28.6)
10,730
(47.7)
7,590
(33.8)
10,120
(45.0)
16,865
(75.0)
10,615
(47.2)
14,640
(65.1)
24,395
(108.5)
12,665
(56.3)
16,885
(75.1)
28,140
(125.2)
16,340
(72.7)
22,150
(98.5)
36,920
(164.2)
19,500
(86.7)
28,160
(125.3)
46,935
(208.8)
22,840
(101.6)
34,840
(155.0)
58,070
(258.3)
2,700
(12.0)
3,600
(16.0)
5,995
(26.7)
4,830
(21.5)
6,440
(28.6)
10,730
(47.7)
7,590
(33.8)
10,120
(45.0)
16,865
(75.0)
10,980
(48.8)
14,640
(65.1)
24,395
(108.5)
12,665
(56.3)
16,885
(75.1)
28,140
(125.2)
16,615
(73.9)
22,150
(98.5)
36,920
(164.2)
21,120
(93.9)
28,160
(125.3)
46,935
(208.8)
26,130
(116.2)
34,840
(155.0)
58,070
(258.3)
2,860
(12.7)
3,815
(17.0)
6,355
(28.3)
5,120
(22.8)
6,825
(30.4)
11,375
(50.6)
8,045
(35.8)
10,725
(47.7)
17,875
(79.5)
11,635
(51.8)
15,515
(69.0)
25,860
(115.0)
13,425
(59.7)
17,900
(79.6)
29,830
(132.7)
17,610
(78.3)
23,480
(104.4)
39,135
(174.1)
22,385
(99.6)
29,850
(132.8)
49,750
(221.3)
27,700
(123.2)
36,935
(164.3)
61,555
(273.8)
5,810
(25.8)
7,750
(34.5)
12,915
(57.4)
10,400
(46.3)
13,870
(61.7)
23,115
(102.8)
15,875
(70.6)
21,790
(96.9)
36,320
(161.6)
20,870
(92.8)
31,530
(140.3)
52,550
(233.8)
26,300
(117.0)
36,370
(161.8)
60,615
(269.6)
32,130
(142.9)
47,710
(212.2)
79,520
(353.7)
38,340
(170.5)
59,025
(262.6)
101,090
(449.7)
44,905
(199.7)
69,135
(307.5)
125,075
(556.4)
5,810
(25.8)
7,750
(34.5)
12,915
(57.4)
10,400
(46.3)
13,870
(61.7)
23,115
(102.8)
16,345
(72.7)
21,790
(96.9)
36,320
(161.6)
22,860
(101.7)
31,530
(140.3)
52,550
(233.8)
27,275
(121.3)
36,370
(161.8)
60,615
(269.6)
35,195
(156.6)
47,710
(212.2)
79,520
(353.7)
42,000
(186.8)
60,655
(269.8)
101,090
(449.7)
49,190
(218.8)
75,045
(333.8)
125,075
(556.4)
5,810
(25.8)
7,750
(34.5)
12,915
(57.4)
10,400
(46.3)
13,870
(61.7)
23,115
(102.8)
16,345
(72.7)
21,790
(96.9)
36,320
(161.6)
23,645
(105.2)
31,530
(140.3)
52,550
(233.8)
27,275
(121.3)
36,370
(161.8)
60,615
(269.6)
35,785
(159.2)
47,710
(212.2)
79,520
(353.7)
45,490
(202.3)
60,655
(269.8)
101,090
(449.7)
56,285
(250.4)
75,045
(333.8)
125,075
(556.4)
6,160
(27.4)
8,215
(36.5)
13,690
(60.9)
11,025
(49.0)
14,700
(65.4)
24,500
(109.0)
17,325
(77.1)
23,100
(102.8)
38,500
(171.3)
25,065
(111.5)
33,420
(148.7)
55,700
(247.8)
28,910
(128.6)
38,550
(171.5)
64,250
(285.8)
37,930
(168.7)
50,575
(225.0)
84,290
(374.9)
48,220
(214.5)
64,290
(286.0)
107,155
(476.6)
59,660
(265.4)
79,545
(353.8)
132,580
(589.7)
3.2.3
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
1
2
3
4
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 71
Shear
Vsa
lb (kN)
4,290
(19.1)
7,800
(34.7)
12,090
(53.8)
17,160
(76.3)
23,400
(104.1)
30,810
(137.0)
39,000
(173.5)
49,530
(220.3)
2,375
(10.6)
4,320
(19.2)
6,695
(29.8)
9,505
(42.3)
12,960
(57.6)
17,065
(75.9)
21,600
(96.1)
27,430
(122.0)
Rebar size
#3
#4
#5
#6
#7
#8
#9
#10
Tensile
Nsa
lb (kN)
Shear
Vsa
lb (kN)
6,435
(28.6)
11,700
(52.0)
18,135
(80.7)
25,740
(114.5)
35,100
(156.1)
46,215
(205.6)
58,500
(260.2)
74,295
(330.5)
3,565
(15.9)
6,480
(28.8)
10,045
(44.7)
14,255
(63.4)
19,440
(86.5)
25,595
(113.9)
32,400
(144.1)
41,150
(183.0)
seis,V7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
Tensile
Nsa
lb (kN)
Shear2
Vsa
lb (kN)
6,600
(29.4)
12,000
(53.4)
18,600
(82.7)
26,400
(117.4)
36,000
(160.1)
47,400
(210.8)
60,000
(266.9)
76,200
(339.0)
3,430
(15.3)
6,240
(27.8)
9,670
(43.0)
13,730
(61.1)
18,720
(83.3)
24,650
(109.6)
31,200
(138.8)
39,625
(176.3)
seis,V7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
seis,V7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
72 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
1-7/8
(48)
2
(51)
3
(76)
3-5/8
(92)
4
(102)
4-5/8 (117)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
8
(203)
8-3/4 (222)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
24
(610)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
(86)
n/a
0.59
0.60
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.85
0.90
0.93
0.94
0.99
1.00
(114)
n/a
0.57
0.57
0.61
0.63
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.82
0.83
0.87
0.91
0.94
1.00
(191)
n/a
0.54
0.54
0.57
0.58
0.59
0.60
0.61
0.63
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.81
0.86
0.90
1.00
(86)
0.31
0.32
0.32
0.40
0.45
0.48
0.54
0.58
0.66
0.69
0.81
0.92
1.00
(114)
0.22
0.23
0.24
0.29
0.33
0.35
0.39
0.42
0.48
0.50
0.59
0.67
0.74
0.76
0.84
0.92
1.00
(191)
0.13
0.13
0.14
0.17
0.19
0.20
0.23
0.24
0.28
0.29
0.34
0.39
0.43
0.44
0.49
0.54
0.58
0.68
0.78
0.88
1.00
(86)
n/a
0.53
0.54
0.55
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.65
0.66
0.68
0.69
0.71
0.75
0.78
0.82
0.92
1.00
(114)
n/a
0.53
0.53
0.54
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.62
0.63
0.63
0.65
0.66
0.67
0.70
0.73
0.76
0.85
0.94
1.00
(191)
n/a
0.52
0.52
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.65
0.67
0.69
0.75
0.81
0.87
1.00
(86)
0.08
0.09
0.10
0.18
0.24
0.28
0.34
0.38
0.47
0.51
0.64
0.78
0.89
0.93
1.00
(114)
0.06
0.07
0.07
0.13
0.18
0.21
0.26
0.29
0.36
0.38
0.48
0.58
0.67
0.70
0.82
0.94
1.00
(191)
0.04
0.04
0.04
0.08
0.11
0.12
0.15
0.17
0.21
0.23
0.29
0.35
0.40
0.42
0.49
0.57
0.64
0.81
0.99
1.00
(86)
0.16
0.18
0.19
0.36
0.46
0.49
0.54
0.58
0.66
0.69
0.81
0.92
1.00
(114)
0.12
0.13
0.15
0.27
0.36
0.40
0.43
0.46
0.50
0.52
0.59
0.67
0.74
0.76
0.84
0.92
1.00
(191)
0.07
0.08
0.09
0.16
0.21
0.25
0.31
0.33
0.35
0.36
0.39
0.43
0.45
0.46
0.50
0.54
0.58
0.68
0.78
0.88
1.00
(86)
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.64
0.65
0.70
0.75
0.79
0.80
0.84
0.88
0.92
0.99
1.00
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.59
0.64
0.68
0.71
0.72
0.76
0.80
0.84
0.90
0.97
1.00
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.61
0.64
0.68
0.71
0.76
0.81
0.86
1.00
3.2.3
3.2.4
3.2.4
3.2.4
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
1-7/8
(48)
2
(51)
3
(76)
3-5/8
(92)
4
(102)
4-5/8 (117)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
8
(203)
8-3/4 (222)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
(457)
18
24
(610)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
(86)
n/a
0.59
0.60
0.65
0.68
0.70
0.73
0.75
0.78
0.80
0.85
0.90
0.93
0.94
0.99
1.00
(114)
n/a
0.57
0.57
0.61
0.63
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.82
0.83
0.87
0.91
0.94
1.00
(191)
n/a
0.54
0.54
0.57
0.58
0.59
0.60
0.61
0.63
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.81
0.86
0.90
1.00
(86)
0.54
0.56
0.57
0.70
0.78
0.84
0.93
0.99
1.00
(114)
0.49
0.50
0.51
0.60
0.66
0.70
0.76
0.80
0.88
0.91
1.00
(191)
0.43
0.44
0.44
0.49
0.53
0.55
0.58
0.60
0.64
0.66
0.72
0.78
0.83
0.85
0.91
0.98
1.00
(86)
n/a
0.54
0.54
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.67
0.67
0.69
0.71
0.73
0.77
0.81
0.85
0.96
1.00
(114)
n/a
0.53
0.53
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.64
0.66
0.67
0.69
0.72
0.75
0.79
0.88
0.98
1.00
(191)
n/a
0.52
0.52
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.68
0.70
0.77
0.84
0.91
1.00
(86)
0.09
0.10
0.11
0.20
0.27
0.31
0.39
0.44
0.54
0.58
0.72
0.89
1.00
(114)
0.07
0.08
0.08
0.15
0.20
0.23
0.29
0.33
0.40
0.43
0.54
0.66
0.76
0.79
0.93
1.00
(191)
0.04
0.05
0.05
0.09
0.12
0.14
0.18
0.20
0.24
0.26
0.33
0.40
0.46
0.48
0.56
0.64
0.73
0.92
1.00
(86)
0.18
0.20
0.22
0.41
0.54
0.63
0.78
0.87
1.00
(114)
0.14
0.15
0.17
0.30
0.41
0.47
0.58
0.66
0.81
0.86
1.00
(191)
0.08
0.09
0.10
0.18
0.24
0.28
0.35
0.39
0.49
0.52
0.65
0.78
0.83
0.85
0.91
0.98
1.00
(86)
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.62
0.66
0.68
0.73
0.78
0.82
0.83
0.88
0.92
0.96
1.00
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.62
0.67
0.71
0.74
0.76
0.80
0.84
0.87
0.94
1.00
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.64
0.67
0.70
0.74
0.79
0.85
0.90
1.00
3.2.5
3.2.6
3.2.7
3.2.8
in.
(mm)
1-3/4
2-1/2
3
4
5
5-3/4
6
7
7-1/4
8
9
10
11-1/4
12
14
16
18
20
22
24
30
36
>48
(44)
(64)
(76)
(102)
(127)
(146)
(152)
(178)
(184)
(203)
(229)
(254)
(286)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
(762)
(914)
(1219)
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
4-1/2
10
4-1/2
10
4-1/2
10
4-1/2
10
4-1/2
10
4-1/2
10
(114)
n/a
0.59
0.61
0.65
0.69
0.71
0.72
0.76
0.77
0.80
0.83
0.87
0.92
0.94
1.00
(152)
n/a
0.57
0.58
0.61
0.64
0.66
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
(254)
n/a
0.54
0.55
0.57
0.58
0.60
0.60
0.62
0.62
0.63
0.65
0.67
0.69
0.70
0.73
0.77
0.80
0.83
0.87
0.90
1.00
(114)
0.27
0.31
0.33
0.39
0.45
0.50
0.51
0.59
0.61
0.67
0.76
0.84
0.95
1.00
(152)
0.20
0.23
0.24
0.29
0.33
0.36
0.38
0.43
0.45
0.49
0.55
0.62
0.69
0.74
0.86
0.99
1.00
(254)
0.12
0.13
0.14
0.17
0.19
0.21
0.22
0.25
0.26
0.29
0.32
0.36
0.41
0.43
0.50
0.58
0.65
0.72
0.79
0.87
1.00
(114)
n/a
0.53
0.54
0.55
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.72
0.74
0.77
0.80
0.82
0.90
0.98
1.00
(152)
n/a
0.53
0.53
0.54
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.67
0.70
0.72
0.74
0.76
0.83
0.89
1.00
(254)
n/a
0.52
0.52
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.61
0.62
0.64
0.66
0.67
0.69
0.73
0.78
0.87
(114)
0.05
0.09
0.12
0.18
0.26
0.32
0.34
0.42
0.45
0.52
0.62
0.72
0.86
0.95
1.00
(152)
0.04
0.07
0.09
0.13
0.19
0.23
0.25
0.31
0.33
0.38
0.45
0.53
0.63
0.70
0.88
1.00
(254)
0.02
0.04
0.05
0.08
0.11
0.14
0.15
0.19
0.20
0.23
0.27
0.32
0.38
0.42
0.53
0.64
0.77
0.90
1.00
(114)
0.11
0.18
0.24
0.37
0.46
0.50
0.52
0.59
0.61
0.67
0.76
0.84
0.95
1.00
(152)
0.08
0.13
0.17
0.27
0.37
0.41
0.42
0.46
0.47
0.51
0.55
0.62
0.69
0.74
0.86
0.99
1.00
(254)
0.05
0.08
0.10
0.16
0.23
0.28
0.30
0.33
0.34
0.36
0.38
0.41
0.44
0.46
0.51
0.58
0.65
0.72
0.79
0.87
1.00
(114)
n/a
n/a
n/a
n/a
n/a
0.56
0.57
0.61
0.62
0.66
0.70
0.73
0.78
0.80
0.87
0.93
0.98
1.00
(152)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.59
0.63
0.66
0.70
0.72
0.78
0.84
0.89
0.93
0.98
1.00
(254)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.66
0.71
0.75
0.79
0.83
0.86
0.97
1.00
in.
(mm)
1-3/4
2-1/2
3
4
5
5-3/4
6
7
7-1/4
8
9
10
11-1/4
12
14
16
18
20
22
24
30
36
>48
(44)
(64)
(76)
(102)
(127)
(146)
(152)
(178)
(184)
(203)
(229)
(254)
(286)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
(762)
(914)
(1219)
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
4-1/2
10
4-1/2
10
4-1/2
10
4-1/2
10
4-1/2
10
4-1/2
10
(114)
n/a
0.59
0.61
0.65
0.69
0.71
0.72
0.76
0.77
0.80
0.83
0.87
0.92
0.94
1.00
(152)
n/a
0.57
0.58
0.61
0.64
0.66
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
(254)
n/a
0.54
0.55
0.57
0.58
0.60
0.60
0.62
0.62
0.63
0.65
0.67
0.69
0.70
0.73
0.77
0.80
0.83
0.87
0.90
1.00
(114)
0.49
0.56
0.60
0.70
0.80
0.88
0.91
1.00
(152)
0.45
0.50
0.53
0.60
0.67
0.73
0.75
0.83
0.85
0.91
1.00
(254)
0.41
0.44
0.46
0.49
0.53
0.56
0.57
0.62
0.63
0.66
0.70
0.75
0.81
0.85
0.95
1.00
(114)
n/a
0.54
0.54
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.63
0.64
0.66
0.67
0.70
0.73
0.76
0.79
0.82
0.84
0.93
1.00
(152)
n/a
0.53
0.54
0.55
0.56
0.57
0.57
0.58
0.59
0.59
0.61
0.62
0.63
0.64
0.67
0.69
0.71
0.74
0.76
0.78
0.86
0.93
1.00
(254)
n/a
0.52
0.53
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.65
0.67
0.69
0.70
0.75
0.80
0.90
(114)
0.06
0.10
0.13
0.20
0.28
0.35
0.37
0.47
0.49
0.57
0.68
0.80
0.95
1.00
(152)
0.04
0.07
0.10
0.15
0.21
0.26
0.28
0.35
0.37
0.43
0.51
0.60
0.71
0.79
0.99
1.00
(254)
0.03
0.04
0.06
0.09
0.13
0.16
0.17
0.21
0.22
0.26
0.31
0.36
0.43
0.47
0.60
0.73
0.87
1.00
(114)
0.12
0.20
0.26
0.40
0.56
0.70
0.74
0.94
0.99
1.00
(152)
0.09
0.15
0.20
0.30
0.42
0.52
0.56
0.70
0.74
0.86
1.00
(254)
0.05
0.09
0.12
0.18
0.25
0.31
0.33
0.42
0.44
0.51
0.61
0.72
0.81
0.85
0.95
1.00
(114)
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.63
0.64
0.68
0.72
0.76
0.80
0.83
0.90
0.96
1.00
(152)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.62
0.65
0.69
0.73
0.75
0.81
0.87
0.92
0.97
1.00
(254)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.64
0.69
0.73
0.78
0.82
0.86
0.90
1.00
74 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
3-1/8
(79)
4
(102)
4-5/8 (117)
5
(127)
6
(152)
7
(178)
7-1/8 (181)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
(143)
n/a
0.59
0.62
0.64
0.65
0.68
0.71
0.71
0.74
0.77
0.80
0.83
0.86
0.91
0.97
1.00
(191)
n/a
0.57
0.59
0.60
0.61
0.63
0.66
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.86
0.90
0.94
0.99
1.00
(318)
n/a
0.54
0.55
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.79
0.82
0.85
0.87
0.90
0.98
1.00
(143)
0.25
0.31
0.34
0.37
0.39
0.43
0.48
0.49
0.54
0.60
0.67
0.74
0.80
0.94
1.00
(191)
0.18
0.22
0.25
0.27
0.28
0.32
0.36
0.36
0.39
0.44
0.49
0.54
0.59
0.69
0.79
0.89
0.98
1.00
(318)
0.11
0.13
0.15
0.16
0.17
0.19
0.21
0.21
0.23
0.26
0.29
0.32
0.35
0.40
0.46
0.52
0.58
0.63
0.69
0.75
0.81
0.86
1.00
(143)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.64
0.66
0.69
0.71
0.73
0.75
0.78
0.80
0.82
0.85
0.92
1.00
(191)
n/a
0.53
0.53
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.62
0.64
0.66
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
(318)
n/a
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.57
0.59
0.60
0.61
0.62
0.64
0.65
0.66
0.67
0.69
0.72
0.80
(143)
0.04
0.10
0.15
0.18
0.21
0.27
0.34
0.35
0.41
0.50
0.58
0.67
0.76
0.96
1.00
(191)
0.03
0.07
0.10
0.12
0.13
0.18
0.22
0.23
0.27
0.32
0.38
0.44
0.50
0.63
0.77
0.92
1.00
(318)
0.02
0.04
0.06
0.07
0.08
0.11
0.13
0.14
0.16
0.19
0.23
0.26
0.30
0.38
0.46
0.55
0.64
0.74
0.85
0.95
1.00
(143)
0.08
0.20
0.29
0.36
0.39
0.44
0.49
0.50
0.54
0.60
0.67
0.74
0.80
0.94
1.00
(191)
0.06
0.13
0.19
0.24
0.27
0.35
0.40
0.40
0.43
0.47
0.51
0.54
0.59
0.69
0.79
0.89
0.98
1.00
(318)
0.03
0.08
0.12
0.14
0.16
0.21
0.27
0.27
0.32
0.34
0.36
0.38
0.40
0.44
0.48
0.52
0.58
0.63
0.69
0.75
0.81
0.86
1.00
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.61
0.65
0.68
0.71
0.75
0.81
0.86
0.91
0.96
1.00
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.59
0.62
0.65
0.70
0.75
0.79
0.84
0.88
0.92
0.95
0.99
1.00
(318)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.63
0.67
0.71
0.74
0.77
0.80
0.83
0.86
0.95
1.00
3.2.3
3.2.4
3.2.4
3.2.4
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
3-1/8
(79)
4
(102)
4-5/8 (117)
5
(127)
6
(152)
7
(178)
7-1/8 (181)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
5-5/8
7-1/2
12-1/2
(143)
n/a
0.59
0.62
0.64
0.65
0.68
0.71
0.71
0.74
0.77
0.80
0.83
0.86
0.91
0.97
1.00
(191)
n/a
0.57
0.59
0.60
0.61
0.63
0.66
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.86
0.90
0.94
0.99
1.00
(318)
n/a
0.54
0.55
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.79
0.82
0.85
0.87
0.90
0.98
1.00
(143)
0.46
0.56
0.62
0.67
0.70
0.78
0.87
0.88
0.96
1.00
(191)
0.43
0.50
0.55
0.58
0.60
0.66
0.72
0.73
0.78
0.85
0.91
0.98
1.00
(318)
0.40
0.44
0.46
0.48
0.49
0.53
0.56
0.56
0.59
0.62
0.66
0.69
0.73
0.81
0.89
0.97
1.00
(143)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.64
0.66
0.69
0.71
0.73
0.76
0.78
0.80
0.83
0.85
0.92
1.00
(191)
n/a
0.53
0.54
0.54
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.73
0.75
0.76
0.78
0.84
0.95
(318)
n/a
0.52
0.53
0.53
0.53
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.61
0.62
0.63
0.65
0.66
0.67
0.69
0.70
0.74
0.82
(143)
0.04
0.10
0.15
0.18
0.21
0.27
0.34
0.35
0.42
0.50
0.58
0.67
0.77
0.97
1.00
(191)
0.03
0.07
0.11
0.13
0.15
0.20
0.25
0.26
0.30
0.36
0.43
0.49
0.56
0.71
0.86
1.00
(318)
0.02
0.04
0.06
0.08
0.09
0.12
0.15
0.15
0.18
0.22
0.26
0.29
0.34
0.42
0.52
0.62
0.72
0.83
0.95
1.00
(143)
0.09
0.20
0.30
0.37
0.41
0.54
0.68
0.70
0.84
1.00
(191)
0.06
0.15
0.22
0.27
0.30
0.40
0.50
0.51
0.61
0.73
0.85
0.98
1.00
(318)
0.04
0.09
0.13
0.16
0.18
0.24
0.30
0.31
0.37
0.44
0.51
0.59
0.67
0.81
0.89
0.97
1.00
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.65
0.68
0.72
0.75
0.81
0.86
0.92
0.97
1.00
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.64
0.67
0.73
0.78
0.82
0.87
0.91
0.95
0.99
1.00
(318)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.66
0.70
0.73
0.77
0.80
0.84
0.87
0.90
0.98
1.00
3.2.5
3.2.6
3.2.7
3.2.8
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
(mm)
6-3/4
15
6-3/4
15
6-3/4
15
6-3/4
15
6-3/4
15
6-3/4
15
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
1-3/4
(44)
3-3/4
(95)
4
(102)
5
(127)
5-1/4 (133)
6
(152)
7
(178)
8
(203)
8-1/2 (216)
9
(229)
10
(254)
10-3/4 (273)
12
(305)
14
(356)
16
(406)
16-3/4 (425)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.70
0.71
0.72
0.75
0.77
0.80
0.85
0.90
0.91
0.94
0.99
1.00
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.69
0.70
0.72
0.76
0.80
0.81
0.83
0.87
0.91
0.94
0.98
1.00
n/a
0.54
0.54
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
0.24
0.30
0.31
0.35
0.36
0.39
0.43
0.47
0.49
0.51
0.56
0.60
0.67
0.78
0.89
0.93
1.00
0.18
0.22
0.23
0.26
0.26
0.28
0.31
0.34
0.36
0.37
0.41
0.44
0.49
0.57
0.65
0.69
0.74
0.82
0.90
0.98
1.00
0.10
0.13
0.14
0.15
0.15
0.17
0.18
0.20
0.21
0.22
0.24
0.26
0.29
0.34
0.38
0.40
0.43
0.48
0.53
0.58
0.62
0.67
0.72
0.86
1.00
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.70
0.72
0.74
0.76
0.78
0.80
0.86
0.99
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.61
0.62
0.63
0.64
0.65
0.67
0.68
0.70
0.71
0.73
0.77
0.86
n/a
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.64
0.65
0.68
0.75
0.03
0.11
0.12
0.17
0.18
0.22
0.28
0.34
0.37
0.40
0.47
0.53
0.62
0.78
0.96
1.00
0.02
0.07
0.08
0.11
0.12
0.14
0.18
0.22
0.24
0.26
0.31
0.34
0.40
0.51
0.62
0.67
0.74
0.87
1.00
0.01
0.04
0.04
0.06
0.06
0.08
0.10
0.12
0.13
0.14
0.17
0.19
0.22
0.28
0.34
0.37
0.41
0.48
0.55
0.63
0.71
0.80
0.88
1.00
0.07
0.22
0.24
0.33
0.36
0.39
0.43
0.47
0.49
0.51
0.56
0.60
0.67
0.78
0.89
0.93
1.00
0.05
0.14
0.16
0.22
0.23
0.29
0.36
0.39
0.40
0.41
0.44
0.47
0.50
0.57
0.65
0.69
0.74
0.82
0.90
0.98
1.00
0.02
0.08
0.09
0.12
0.13
0.16
0.20
0.24
0.27
0.29
0.32
0.34
0.36
0.39
0.42
0.43
0.46
0.49
0.53
0.58
0.62
0.67
0.72
0.86
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.60
0.64
0.66
0.70
0.75
0.80
0.82
0.85
0.90
0.94
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.65
0.70
0.71
0.74
0.78
0.82
0.85
0.89
0.92
0.95
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.64
0.67
0.70
0.73
0.76
0.78
0.86
0.99
Embedment hef
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
(mm)
6-3/4
15
6-3/4
15
6-3/4
15
6-3/4
15
6-3/4
15
6-3/4
15
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
(171)
(229)
(381)
1-3/4
(44)
3-3/4
(95)
4
(102)
5
(127)
5-1/4 (133)
6
(152)
7
(178)
8
(203)
8-1/2 (216)
9
(229)
10
(254)
10-3/4 (273)
12
(305)
14
(356)
16
(406)
16-3/4 (425)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.70
0.71
0.72
0.75
0.77
0.80
0.85
0.90
0.91
0.94
0.99
1.00
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.69
0.70
0.72
0.76
0.80
0.81
0.83
0.87
0.91
0.94
0.98
1.00
n/a
0.54
0.54
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
0.44
0.56
0.57
0.63
0.65
0.70
0.77
0.84
0.88
0.91
0.99
1.00
0.42
0.50
0.51
0.56
0.57
0.60
0.65
0.70
0.72
0.75
0.80
0.84
0.91
1.00
0.39
0.44
0.44
0.47
0.47
0.49
0.52
0.55
0.56
0.57
0.60
0.62
0.66
0.72
0.78
0.81
0.85
0.91
0.98
1.00
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.70
0.72
0.74
0.76
0.79
0.81
0.87
0.99
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.61
0.62
0.63
0.64
0.65
0.67
0.69
0.70
0.72
0.73
0.78
0.87
n/a
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.64
0.65
0.66
0.70
0.76
0.03
0.11
0.12
0.17
0.18
0.22
0.28
0.34
0.37
0.41
0.48
0.53
0.63
0.79
0.97
1.00
0.02
0.07
0.08
0.11
0.12
0.15
0.19
0.23
0.25
0.27
0.32
0.35
0.42
0.52
0.64
0.68
0.76
0.89
1.00
0.01
0.04
0.05
0.07
0.07
0.09
0.11
0.14
0.15
0.16
0.19
0.21
0.25
0.31
0.38
0.41
0.46
0.54
0.62
0.70
0.79
0.89
0.99
1.00
0.07
0.22
0.24
0.34
0.36
0.44
0.56
0.68
0.75
0.82
0.95
1.00
0.05
0.15
0.16
0.22
0.24
0.29
0.37
0.45
0.50
0.54
0.63
0.70
0.83
1.00
0.03
0.09
0.10
0.13
0.14
0.18
0.22
0.27
0.30
0.32
0.38
0.42
0.50
0.63
0.77
0.81
0.85
0.91
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.64
0.66
0.70
0.76
0.81
0.83
0.86
0.90
0.95
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.66
0.70
0.72
0.75
0.79
0.82
0.86
0.90
0.93
0.96
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.63
0.66
0.70
0.73
0.76
0.78
0.81
0.89
1.00
Embedment hef
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
(mm)
7-7/8
(200)
(267)
(445)
(200)
(267)
(445)
(200)
(267)
(445)
(200)
(267)
(445)
(200)
(267)
(445)
(200)
(267)
(445)
1-3/4
(44)
4-3/8 (111)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
9-7/8 (251)
10
(254)
11
(279)
12
(305)
12-1/2 (318)
14
(356)
16
(406)
18
(457)
19-1/2 (495)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
n/a
0.59
0.61
0.62
0.63
0.65
0.67
0.69
0.71
0.71
0.73
0.75
0.76
0.80
0.84
0.88
0.91
0.92
0.97
1.00
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.66
0.66
0.67
0.69
0.70
0.72
0.75
0.79
0.81
0.82
0.85
0.88
0.91
0.94
0.98
1.00
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.75
0.77
0.79
0.84
0.96
0.23
0.30
0.32
0.34
0.35
0.39
0.42
0.45
0.49
0.49
0.53
0.57
0.60
0.67
0.76
0.86
0.93
0.95
1.00
0.17
0.22
0.24
0.25
0.26
0.28
0.31
0.33
0.36
0.36
0.39
0.42
0.44
0.49
0.56
0.63
0.68
0.70
0.77
0.84
0.91
0.98
1.00
0.10
0.13
0.14
0.15
0.15
0.17
0.18
0.20
0.21
0.21
0.23
0.25
0.26
0.29
0.33
0.37
0.40
0.41
0.45
0.49
0.53
0.58
0.62
0.74
0.99
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.67
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.63
0.64
0.66
0.67
0.68
0.70
0.73
0.81
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.62
0.65
0.70
0.03
0.11
0.13
0.15
0.17
0.22
0.27
0.32
0.37
0.38
0.43
0.49
0.52
0.62
0.76
0.91
1.00
0.02
0.07
0.09
0.10
0.11
0.14
0.17
0.21
0.24
0.24
0.28
0.32
0.34
0.40
0.49
0.59
0.66
0.69
0.80
0.91
1.00
0.01
0.04
0.04
0.05
0.06
0.07
0.09
0.11
0.12
0.12
0.14
0.16
0.17
0.21
0.25
0.30
0.34
0.35
0.41
0.46
0.52
0.58
0.65
0.85
1.00
0.05
0.22
0.27
0.31
0.35
0.39
0.43
0.46
0.49
0.50
0.53
0.57
0.60
0.67
0.76
0.86
0.93
0.95
1.00
0.04
0.14
0.17
0.20
0.23
0.29
0.35
0.38
0.40
0.40
0.43
0.45
0.46
0.50
0.56
0.63
0.68
0.70
0.77
0.84
0.91
0.98
1.00
0.02
0.07
0.09
0.10
0.12
0.15
0.18
0.21
0.24
0.25
0.29
0.33
0.34
0.36
0.38
0.41
0.43
0.44
0.47
0.50
0.54
0.58
0.62
0.74
0.99
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.62
0.65
0.66
0.70
0.75
0.79
0.82
0.83
0.87
0.91
0.95
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.65
0.68
0.71
0.72
0.76
0.79
0.82
0.85
0.88
0.97
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.58
0.60
0.63
0.66
0.68
0.71
0.77
0.89
Embedment hef
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Spacing factor in
tension
AN
10-1/2 17-1/2
7-7/8
10-1/2 17-1/2
7-7/8
10-1/2 17-1/2
7-7/8
10-1/2 17-1/2
7-7/8
10-1/2 17-1/2
7-7/8
10-1/2 17-1/2
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
4-3/8 (111)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
9-7/8 (251)
10
(254)
11
(279)
12
(305)
12-1/2 (318)
14
(356)
16
(406)
18
(457)
19-1/2 (495)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
Spacing factor in
tension
AN
7-7/8
(200)
n/a
0.59
0.61
0.62
0.63
0.65
0.67
0.69
0.71
0.71
0.73
0.75
0.76
0.80
0.84
0.88
0.91
0.92
0.97
1.00
10-1/2 17-1/2
(267)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.66
0.66
0.67
0.69
0.70
0.72
0.75
0.79
0.81
0.82
0.85
0.88
0.91
0.94
0.98
1.00
(445)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.75
0.77
0.79
0.84
0.96
10-1/2 17-1/2
(267)
0.41
0.50
0.52
0.54
0.56
0.60
0.64
0.68
0.72
0.73
0.77
0.82
0.84
0.91
1.00
(445)
0.38
0.44
0.45
0.46
0.47
0.49
0.52
0.54
0.56
0.56
0.59
0.61
0.62
0.66
0.71
0.76
0.80
0.82
0.87
0.93
0.99
1.00
Spacing factor in
shear4
AV
7-7/8
(200)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.67
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
10-1/2 17-1/2
(267)
n/a
0.53
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.64
0.64
0.65
0.67
0.68
0.70
0.71
0.75
0.84
(445)
n/a
0.52
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.62
0.63
0.64
0.65
0.68
0.74
To edge
RV
Toward edge
RV
7-7/8
(200)
0.03
0.11
0.13
0.15
0.18
0.22
0.27
0.32
0.37
0.38
0.44
0.50
0.53
0.63
0.77
0.91
1.00
10-1/2 17-1/2
(267)
0.02
0.08
0.10
0.11
0.13
0.16
0.20
0.23
0.27
0.27
0.32
0.36
0.38
0.45
0.55
0.66
0.75
0.77
0.89
1.00
(445)
0.01
0.05
0.06
0.07
0.08
0.10
0.12
0.14
0.16
0.16
0.19
0.22
0.23
0.27
0.33
0.40
0.45
0.46
0.54
0.61
0.69
0.77
0.85
1.00
7-7/8
(200)
0.06
0.22
0.27
0.31
0.35
0.44
0.54
0.65
0.74
0.76
0.87
1.00
1.00
Concrete thickness
factor in shear5
HV
10-1/2 17-1/2
(267)
0.04
0.16
0.19
0.22
0.25
0.32
0.39
0.47
0.54
0.55
0.63
0.72
0.77
0.91
1.00
(445)
0.02
0.10
0.12
0.13
0.15
0.19
0.24
0.28
0.32
0.33
0.38
0.43
0.46
0.54
0.67
0.76
0.80
0.82
0.87
0.93
0.99
1.00
7-7/8
(200)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.62
0.65
0.66
0.70
0.75
0.79
0.82
0.84
0.88
0.92
0.95
0.99
1.00
10-1/2 17-1/2
(267)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.63
0.67
0.71
0.74
0.75
0.79
0.82
0.86
0.89
0.92
1.00
(445)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.63
0.66
0.69
0.72
0.75
0.77
0.85
0.98
3.2.3
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
5
(127)
6
(152)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
11-1/4 (286)
12
(305)
13
(330)
14
(356)
14-1/4 (362)
16
(406)
18
(457)
20
(508)
22
(559)
22-1/4 (565)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
12
20
12
20
12
20
12
20
12
20
12
20
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
n/a
0.59
0.61
0.62
0.63
0.65
0.67
0.69
0.70
0.71
0.72
0.74
0.76
0.76
0.80
0.83
0.87
0.91
0.91
0.94
0.98
1.00
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.72
0.75
0.78
0.81
0.81
0.83
0.86
0.89
0.92
1.00
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.62
0.63
0.65
0.67
0.68
0.69
0.70
0.72
0.73
0.75
0.80
0.90
0.23
0.30
0.33
0.34
0.36
0.39
0.41
0.44
0.48
0.48
0.51
0.54
0.58
0.59
0.67
0.75
0.83
0.92
0.93
1.00
1.00
0.17
0.22
0.24
0.25
0.26
0.28
0.30
0.33
0.35
0.36
0.37
0.40
0.43
0.44
0.49
0.55
0.61
0.67
0.68
0.74
0.80
0.86
0.92
1.00
0.10
0.13
0.14
0.15
0.15
0.17
0.18
0.19
0.21
0.21
0.22
0.23
0.25
0.26
0.29
0.32
0.36
0.40
0.40
0.43
0.47
0.50
0.54
0.65
0.86
n/a
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.61
0.62
0.64
0.65
0.67
0.67
0.68
0.70
0.71
0.73
0.77
0.86
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.63
0.64
0.65
0.66
0.67
0.70
0.77
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.58
0.59
0.60
0.60
0.63
0.67
0.02
0.11
0.14
0.15
0.18
0.22
0.26
0.31
0.35
0.37
0.40
0.46
0.51
0.52
0.62
0.74
0.87
1.00
0.01
0.07
0.09
0.10
0.12
0.14
0.17
0.20
0.23
0.24
0.26
0.30
0.33
0.34
0.40
0.48
0.56
0.65
0.66
0.74
0.84
0.94
1.00
0.01
0.03
0.04
0.05
0.06
0.07
0.08
0.10
0.11
0.11
0.13
0.14
0.16
0.16
0.19
0.23
0.27
0.31
0.32
0.35
0.40
0.45
0.50
0.65
1.00
0.05
0.22
0.29
0.30
0.36
0.39
0.42
0.45
0.48
0.49
0.51
0.55
0.58
0.59
0.67
0.75
0.83
0.92
0.93
1.00
1.00
0.03
0.14
0.19
0.20
0.23
0.29
0.34
0.37
0.39
0.40
0.41
0.44
0.46
0.46
0.50
0.55
0.61
0.67
0.68
0.74
0.80
0.86
0.92
1.00
0.01
0.07
0.09
0.09
0.11
0.14
0.16
0.19
0.22
0.23
0.25
0.28
0.32
0.32
0.36
0.38
0.40
0.43
0.43
0.46
0.48
0.51
0.54
0.65
0.86
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.60
0.63
0.65
0.66
0.70
0.74
0.78
0.82
0.82
0.85
0.89
0.92
0.95
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.64
0.67
0.71
0.71
0.74
0.77
0.80
0.83
0.91
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.58
0.60
0.62
0.65
0.71
0.82
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
5
(127)
6
(152)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
11-1/4 (286)
12
(305)
13
(330)
14
(356)
14-1/4 (362)
16
(406)
18
(457)
20
(508)
22
(559)
22-1/4 (565)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
Spacing factor in
tension
AN
Spacing factor in
shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
12
20
12
20
12
20
12
20
12
20
12
20
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
(229)
(305)
(508)
n/a
0.59
0.61
0.62
0.63
0.65
0.67
0.69
0.70
0.71
0.72
0.74
0.76
0.76
0.80
0.83
0.87
0.91
0.91
0.94
0.98
1.00
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.72
0.75
0.78
0.81
0.81
0.83
0.86
0.89
0.92
1.00
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.62
0.63
0.65
0.67
0.68
0.69
0.70
0.72
0.73
0.75
0.80
0.90
0.42
0.56
0.60
0.61
0.65
0.70
0.75
0.80
0.86
0.87
0.91
0.97
1.00
0.40
0.50
0.53
0.54
0.57
0.60
0.64
0.67
0.71
0.72
0.75
0.79
0.83
0.84
0.91
1.00
0.38
0.44
0.46
0.46
0.47
0.49
0.51
0.53
0.55
0.56
0.57
0.59
0.62
0.62
0.66
0.70
0.75
0.80
0.80
0.85
0.90
0.95
1.00
n/a
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.61
0.62
0.64
0.65
0.67
0.67
0.68
0.70
0.71
0.73
0.77
0.87
n/a
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.58
0.59
0.61
0.62
0.63
0.63
0.64
0.65
0.66
0.68
0.71
0.78
n/a
0.52
0.53
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.65
0.70
0.02
0.11
0.14
0.15
0.18
0.22
0.26
0.31
0.36
0.37
0.41
0.46
0.51
0.53
0.63
0.75
0.88
1.00
0.02
0.07
0.10
0.10
0.12
0.15
0.18
0.21
0.24
0.25
0.27
0.31
0.35
0.36
0.42
0.50
0.59
0.68
0.69
0.78
0.88
0.98
1.00
0.01
0.04
0.06
0.06
0.07
0.09
0.11
0.13
0.14
0.15
0.16
0.19
0.21
0.21
0.25
0.30
0.35
0.41
0.42
0.47
0.53
0.59
0.65
0.86
1.00
0.05
0.22
0.29
0.31
0.36
0.44
0.53
0.62
0.72
0.74
0.82
0.92
1.00
0.03
0.15
0.19
0.21
0.24
0.30
0.36
0.42
0.48
0.50
0.55
0.62
0.69
0.71
0.85
1.00
0.02
0.09
0.12
0.12
0.15
0.18
0.21
0.25
0.29
0.30
0.33
0.37
0.42
0.43
0.51
0.61
0.71
0.80
0.80
0.85
0.90
0.95
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.63
0.65
0.66
0.70
0.74
0.78
0.82
0.82
0.86
0.89
0.92
0.96
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.65
0.69
0.72
0.72
0.75
0.78
0.81
0.84
0.92
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.63
0.66
0.68
0.71
0.78
0.90
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
in.
(mm)
1-3/4
(44)
5-5/8 (143)
6
(152)
7
(178)
7-1/4 (184)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
12-7/8 (327)
13
(330)
14
(356)
16
(406)
16-1/4 (413)
18
(457)
20
(508)
22
(559)
24
(610)
25-1/4 (641)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
Spacing factor in
tension
AN
Spacing factor in
shear3
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear4
HV
10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
n/a
0.59
0.60
0.62
0.62
0.63
0.65
0.66
0.68
0.70
0.71
0.71
0.73
0.76
0.77
0.80
0.83
0.86
0.90
0.92
0.93
0.96
0.99
1.00
n/a
0.57
0.57
0.59
0.59
0.60
0.61
0.62
0.64
0.65
0.66
0.66
0.67
0.70
0.70
0.72
0.75
0.77
0.80
0.81
0.82
0.85
0.87
0.94
1.00
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.60
0.60
0.62
0.62
0.63
0.65
0.66
0.68
0.69
0.69
0.71
0.72
0.77
0.86
0.22
0.31
0.31
0.34
0.34
0.36
0.39
0.41
0.44
0.47
0.49
0.50
0.53
0.60
0.61
0.67
0.75
0.82
0.89
0.94
0.97
1.00
0.16
0.22
0.23
0.25
0.25
0.27
0.28
0.30
0.32
0.34
0.36
0.36
0.39
0.44
0.44
0.49
0.55
0.60
0.66
0.69
0.71
0.77
0.82
0.99
1.00
0.10
0.13
0.14
0.15
0.15
0.16
0.17
0.18
0.19
0.20
0.21
0.21
0.23
0.26
0.26
0.29
0.32
0.35
0.38
0.40
0.42
0.45
0.48
0.58
0.77
n/a
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.59
0.59
0.61
0.61
0.62
0.63
0.65
0.66
0.67
0.68
0.69
0.70
0.74
0.82
n/a
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.63
0.64
0.65
0.68
0.74
n/a
0.52
0.52
0.52
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.59
0.61
0.65
0.02
0.11
0.12
0.15
0.16
0.18
0.22
0.26
0.30
0.34
0.38
0.38
0.43
0.52
0.53
0.62
0.73
0.84
0.96
1.00
0.01
0.07
0.08
0.10
0.10
0.12
0.14
0.17
0.19
0.22
0.24
0.25
0.28
0.34
0.35
0.40
0.47
0.55
0.62
0.67
0.70
0.78
0.87
1.00
0.01
0.03
0.04
0.05
0.05
0.06
0.07
0.08
0.09
0.10
0.11
0.12
0.13
0.16
0.16
0.19
0.22
0.25
0.29
0.31
0.33
0.36
0.40
0.53
0.82
0.04
0.22
0.24
0.30
0.32
0.37
0.40
0.42
0.45
0.47
0.50
0.50
0.53
0.60
0.61
0.67
0.75
0.82
0.89
0.94
0.97
1.00
0.02
0.14
0.16
0.20
0.21
0.24
0.29
0.33
0.37
0.39
0.40
0.41
0.43
0.46
0.47
0.51
0.55
0.60
0.66
0.69
0.71
0.77
0.82
0.99
1.00
0.01
0.07
0.07
0.09
0.10
0.11
0.13
0.16
0.18
0.20
0.23
0.23
0.26
0.31
0.32
0.36
0.38
0.40
0.42
0.44
0.45
0.47
0.49
0.58
0.77
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.61
0.66
0.66
0.70
0.73
0.77
0.80
0.83
0.84
0.87
0.90
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.64
0.67
0.70
0.71
0.73
0.75
0.78
0.85
0.99
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.56
0.58
0.60
0.66
0.76
3.2.3
3.2.4
3.2.4
3.2.4
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
1
2
3
4
in.
(mm)
1-3/4
(44)
5-5/8 (143)
6
(152)
7
(178)
7-1/4 (184)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
12-7/8 (327)
13
(330)
14
(356)
16
(406)
16-1/4 (413)
18
(457)
20
(508)
22
(559)
24
(610)
25-1/4 (641)
26
(660)
28
(711)
30
(762)
36
(914)
>48
(1219)
Spacing factor in
tension
AN
Spacing factor in
shear3
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear4
HV
10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
(257)
(343)
(572)
n/a
0.59
0.60
0.62
0.62
0.63
0.65
0.66
0.68
0.70
0.71
0.71
0.73
0.76
0.77
0.80
0.83
0.86
0.90
0.92
0.93
0.96
0.99
1.00
n/a
0.57
0.57
0.59
0.59
0.60
0.61
0.62
0.64
0.65
0.66
0.66
0.67
0.70
0.70
0.72
0.75
0.77
0.80
0.81
0.82
0.85
0.87
0.94
1.00
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.60
0.60
0.62
0.62
0.63
0.65
0.66
0.68
0.69
0.69
0.71
0.72
0.77
0.86
0.41
0.56
0.57
0.61
0.62
0.65
0.70
0.74
0.79
0.84
0.88
0.89
0.94
1.00
0.39
0.50
0.51
0.54
0.55
0.57
0.60
0.63
0.67
0.70
0.73
0.73
0.77
0.84
0.85
0.91
0.99
1.00
0.38
0.44
0.44
0.46
0.46
0.48
0.49
0.51
0.53
0.55
0.56
0.56
0.58
0.62
0.63
0.66
0.70
0.74
0.78
0.81
0.82
0.87
0.91
1.00
n/a
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.59
0.60
0.61
0.61
0.62
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.74
0.83
n/a
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.63
0.64
0.65
0.68
0.74
n/a
0.52
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.56
0.57
0.58
0.59
0.59
0.59
0.60
0.61
0.63
0.67
0.02
0.11
0.12
0.15
0.16
0.19
0.22
0.26
0.30
0.34
0.38
0.39
0.43
0.53
0.54
0.63
0.73
0.85
0.97
1.00
0.01
0.07
0.08
0.10
0.10
0.12
0.14
0.17
0.19
0.22
0.25
0.25
0.28
0.34
0.35
0.41
0.48
0.55
0.63
0.68
0.71
0.79
0.88
1.00
0.01
0.04
0.05
0.06
0.06
0.07
0.08
0.10
0.11
0.13
0.14
0.15
0.16
0.20
0.20
0.24
0.28
0.32
0.37
0.40
0.41
0.46
0.51
0.67
1.00
0.04
0.22
0.24
0.30
0.32
0.37
0.44
0.52
0.60
0.68
0.76
0.77
0.86
1.00
0.02
0.14
0.16
0.20
0.21
0.24
0.29
0.34
0.39
0.44
0.49
0.50
0.56
0.68
0.70
0.82
0.95
1.00
0.01
0.08
0.09
0.12
0.12
0.14
0.17
0.20
0.23
0.26
0.29
0.29
0.33
0.40
0.41
0.48
0.56
0.64
0.73
0.79
0.82
0.87
0.91
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.62
0.66
0.66
0.70
0.74
0.77
0.81
0.83
0.84
0.87
0.90
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.64
0.67
0.70
0.72
0.73
0.76
0.78
0.86
0.99
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.61
0.63
0.65
0.72
0.83
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 79
Spacing factor in
tension
AN
in. 11-1/4 15
(mm) (286) (381)
1-3/4 (44)
n/a
n/a
6-1/4 (159) 0.59
0.57
7
(178) 0.60
0.58
8
(203) 0.62
0.59
9
(229) 0.63
0.60
10
(254) 0.65
0.61
11
(279) 0.66
0.62
12
(305) 0.68
0.63
13
(330) 0.69
0.64
14
(356) 0.71
0.66
14-1/4 (362) 0.71
0.66
15
(381) 0.72
0.67
16
(406) 0.74
0.68
17
(432) 0.75
0.69
18
(457) 0.77
0.70
20
(508) 0.80
0.72
22
(559) 0.83
0.74
24
(610) 0.86
0.77
26
(660) 0.89
0.79
28
(711) 0.91
0.81
30
(762) 0.94
0.83
36
(914) 1.00
0.90
>48 (1219)
1.00
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
25 11-1/4 15
(635) (286) (381)
n/a
0.22
0.16
0.54
0.31
0.22
0.55
0.32
0.24
0.55
0.34
0.25
0.56
0.36
0.27
0.57
0.39
0.28
0.57
0.41
0.30
0.58
0.43
0.32
0.59
0.46
0.34
0.59
0.48
0.36
0.60
0.49
0.36
0.60
0.51
0.37
0.61
0.54
0.39
0.61
0.57
0.42
0.62
0.60
0.44
0.63
0.67
0.49
0.65
0.74
0.54
0.66
0.80
0.59
0.67
0.87
0.64
0.69
0.94
0.69
0.70
1.00
0.74
0.74
0.89
0.82
1.00
Spacing factor in
shear3
AV
25 11-1/4 15
(635) (286) (381)
0.09
n/a
n/a
0.13
0.54
0.53
0.14
0.54
0.53
0.15
0.55
0.54
0.16
0.55
0.54
0.17
0.56
0.55
0.18
0.57
0.55
0.19
0.57
0.55
0.20
0.58
0.56
0.21
0.59
0.56
0.21
0.59
0.56
0.22
0.59
0.57
0.23
0.60
0.57
0.24
0.60
0.58
0.26
0.61
0.58
0.29
0.62
0.59
0.32
0.63
0.60
0.35
0.65
0.61
0.37
0.66
0.62
0.40
0.67
0.63
0.43
0.68
0.64
0.52
0.72
0.66
0.69
0.79
0.72
Toward edge
RV
25 11-1/4 15
(635) (286) (381)
n/a
0.02
0.01
0.52
0.11
0.07
0.52
0.13
0.08
0.52
0.16
0.10
0.52
0.19
0.12
0.53
0.22
0.14
0.53
0.25
0.16
0.53
0.29
0.19
0.54
0.33
0.21
0.54
0.36
0.24
0.54
0.37
0.24
0.54
0.40
0.26
0.54
0.45
0.29
0.55
0.49
0.32
0.55
0.53
0.35
0.55
0.62
0.40
0.56
0.72
0.47
0.57
0.82
0.53
0.57
0.92
0.60
0.58
1.00
0.67
0.58
0.74
0.60
0.98
0.63
1.00
To edge
RV
25 11-1/4 15
(635) (286) (381)
0.00
0.03
0.02
0.03
0.22
0.14
0.04
0.26
0.17
0.05
0.31
0.20
0.06
0.37
0.24
0.07
0.39
0.29
0.08
0.42
0.33
0.09
0.44
0.36
0.10
0.47
0.38
0.11
0.49
0.40
0.11
0.50
0.40
0.12
0.52
0.42
0.13
0.54
0.43
0.15
0.57
0.45
0.16
0.60
0.47
0.19
0.67
0.51
0.22
0.74
0.54
0.25
0.80
0.59
0.28
0.87
0.64
0.31
0.94
0.69
0.35
1.00
0.74
0.45
0.89
0.70
1.00
Concrete thickness
factor in shear4
HV
25 11-1/4 15
(635) (286) (381)
0.01
n/a
n/a
0.07
n/a
n/a
0.08
n/a
n/a
0.10
n/a
n/a
0.11
n/a
n/a
0.13
n/a
n/a
0.15
n/a
n/a
0.17
n/a
n/a
0.20
n/a
n/a
0.22
n/a
n/a
0.23
0.59
n/a
0.24
0.60
n/a
0.27
0.62
n/a
0.29
0.64
n/a
0.32
0.66
0.57
0.36
0.70
0.60
0.38
0.73
0.63
0.40
0.76
0.66
0.42
0.79
0.69
0.44
0.82
0.71
0.46
0.85
0.74
0.52
0.94
0.81
0.69
1.00
0.94
25
(635)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.63
0.72
Table 37 - Load adjustment factors for #10 rebar in cracked concrete 1,2
Edge distance in shear
#10
Cracked concrete
in. 11-1/4 15
(mm) (286) (381)
1-3/4 (44)
n/a
n/a
6-1/4 (159) 0.59
0.57
7
(178) 0.60
0.58
8
(203) 0.62
0.59
9
(229) 0.63
0.60
10
(254) 0.65
0.61
11
(279) 0.66
0.62
12
(305) 0.68
0.63
13
(330) 0.69
0.64
14
(356) 0.71
0.66
14-1/4 (362) 0.71
0.66
15
(381) 0.72
0.67
16
(406) 0.74
0.68
17
(432) 0.75
0.69
18
(457) 0.77
0.70
20
(508) 0.80
0.72
22
(559) 0.83
0.74
24
(610) 0.86
0.77
26
(660) 0.89
0.79
28
(711) 0.91
0.81
30
(762) 0.94
0.83
36
(914) 1.00
0.90
>48 (1219)
1.00
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment hef
1
2
3
4
Spacing factor in
tension
AN
25 11-1/4 15
(635) (286) (381)
n/a
0.40
0.39
0.54
0.56
0.50
0.55
0.58
0.52
0.55
0.62
0.55
0.56
0.66
0.57
0.57
0.70
0.60
0.57
0.74
0.63
0.58
0.78
0.66
0.59
0.82
0.69
0.59
0.87
0.72
0.60
0.88
0.73
0.60
0.91
0.75
0.61
0.96
0.78
0.61
1.00
0.81
0.62
0.85
0.63
0.91
0.65
0.98
0.66
1.00
0.67
0.69
0.70
0.74
0.82
Spacing factor in
shear3
AV
25 11-1/4 15
(635) (286) (381)
0.37
n/a
n/a
0.44
0.54
0.53
0.45
0.54
0.53
0.46
0.55
0.54
0.48
0.55
0.54
0.49
0.56
0.55
0.51
0.57
0.55
0.53
0.57
0.55
0.54
0.58
0.56
0.56
0.59
0.56
0.56
0.59
0.57
0.57
0.59
0.57
0.59
0.60
0.57
0.61
0.60
0.58
0.62
0.61
0.58
0.66
0.62
0.59
0.69
0.63
0.60
0.73
0.65
0.61
0.77
0.66
0.62
0.81
0.67
0.63
0.85
0.68
0.64
0.97
0.72
0.66
1.00
0.79
0.72
Toward edge
RV
25 11-1/4 15
(635) (286) (381)
n/a
0.02
0.01
0.52
0.11
0.07
0.52
0.13
0.08
0.52
0.16
0.10
0.53
0.19
0.12
0.53
0.22
0.14
0.53
0.26
0.17
0.54
0.29
0.19
0.54
0.33
0.21
0.54
0.37
0.24
0.54
0.38
0.25
0.55
0.41
0.26
0.55
0.45
0.29
0.55
0.49
0.32
0.56
0.54
0.35
0.56
0.63
0.41
0.57
0.72
0.47
0.57
0.82
0.54
0.58
0.93
0.60
0.59
1.00
0.68
0.59
0.75
0.61
0.98
0.65
1.00
To edge
RV
25 11-1/4 15
(635) (286) (381)
0.01
0.03
0.02
0.04
0.22
0.14
0.05
0.26
0.17
0.06
0.32
0.21
0.07
0.38
0.25
0.08
0.44
0.29
0.09
0.51
0.33
0.10
0.58
0.38
0.12
0.66
0.43
0.13
0.73
0.48
0.14
0.75
0.49
0.15
0.82
0.53
0.16
0.90
0.58
0.18
0.98
0.64
0.19
1.00
0.70
0.23
0.82
0.26
0.94
0.30
1.00
0.33
0.37
0.41
0.54
0.84
Concrete thickness
factor in shear4
HV
25 11-1/4 15
(635) (286) (381)
0.01
n/a
n/a
0.08
n/a
n/a
0.09
n/a
n/a
0.11
n/a
n/a
0.14
n/a
n/a
0.16
n/a
n/a
0.18
n/a
n/a
0.21
n/a
n/a
0.24
n/a
n/a
0.26
n/a
n/a
0.27
0.59
n/a
0.29
0.61
n/a
0.32
0.63
n/a
0.35
0.64
n/a
0.38
0.66
0.57
0.45
0.70
0.61
0.52
0.73
0.63
0.59
0.77
0.66
0.67
0.80
0.69
0.75
0.83
0.72
0.83
0.86
0.74
0.97
0.94
0.81
1.00
1.00
0.94
25
(635)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.67
0.77
80 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Dry
concrete
Cracked
concrete
Water saturated
concrete
Permissible
drilling
method
Permissible
concrete
conditions
Symbol Units
do
hef,std
minimum
hef,min
maximum
hef,max
Effective
embedment
Minimum diameter
through-set
of fixture hole
Minimum diameter
preset
of fixture hole
Installation torque
Tinst
3/8
1/2
in.
7/16
9/16
in.
(mm)
in.
(mm)
(86)
3/4
7/8
1-1/4
1-1/8 1-3/8
9
3.2.3
11-1/4
(70)
(79)
(89)
(89)
(102) (127)
in.
1/2
5/8
in.
7/16
ft-lb
(Nm)
15
(20)
30
(40)
60
(80)
3.2.4
Figure 11 Installation with (2) washers
100
125
150
200
(136) (169) (203) (271)
3.2.4
3.2.4
3.2.5
3.2.8
3.2.6
3.2.7
3/8
1/2
5/8
3/4
7/8
1-1/4
Tension Nn or Nr
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
2-3/8
(60)
3-3/8
(86)
4-1/2
(114)
7-1/2
(191)
2-3/4
(70)
4-1/2
(114)
6
(152)
10
(254)
3-1/8
(79)
5-5/8
(143)
7-1/2
(191)
12-1/2
(318)
3-1/2
(89)
6-3/4
(171)
9
(229)
15
(381)
3-1/2
(89)
7-7/8
(200)
10-1/2
(267)
17-1/2
(445)
4
(102)
9
(229)
12
(305)
20
(508)
5
(127)
11-1/4
(286)
15
(381)
25
(635)
2,855
(12.7)
4,835
(21.5)
6,475
(28.8)
10,790
(48.0)
3,555
(15.8)
7,445
(33.1)
11,465
(51.0)
19,185
(85.3)
4,310
(19.2)
10,405
(46.3)
16,020
(71.3)
29,975
(133.3)
5,105
(22.7)
13,680
(60.9)
21,060
(93.7)
43,165
(192.0)
5,105
(22.7)
17,235
(76.7)
26,540
(118.1)
57,100
(254.0)
6,240
(27.8)
21,060
(93.7)
32,425
(144.2)
69,765
(310.3)
8,720
(38.8)
29,430
(130.9)
45,315
(201.6)
97,500
(433.7)
3,125
(13.9)
4,855
(21.6)
6,475
(28.8)
10,790
(48.0)
3,895
(17.3)
8,155
(36.3)
11,510
(51.2)
19,185
(85.3)
4,720
(21.0)
11,400
(50.7)
17,550
(78.1)
29,975
(133.3)
5,595
(24.9)
14,985
(66.7)
23,070
(102.6)
43,165
(192.0)
5,595
(24.9)
18,885
(84.0)
29,070
(129.3)
58,755
(261.4)
6,835
(30.4)
23,070
(102.6)
35,520
(158.0)
76,425
(340.0)
9,555
(42.5)
32,240
(143.4)
49,640
(220.8)
106,805
(475.1)
3,415
(15.2)
4,855
(21.6)
6,475
(28.8)
10,790
(48.0)
4,500
(20.0)
8,635
(38.4)
11,510
(51.2)
19,185
(85.3)
5,450
(24.2)
13,165
(58.6)
17,985
(80.0)
29,975
(133.3)
6,460
(28.7)
17,305
(77.0)
25,900
(115.2)
43,165
(192.0)
6,460
(28.7)
21,805
(97.0)
33,570
(149.3)
58,755
(261.4)
7,895
(35.1)
26,640
(118.5)
41,015
(182.4)
76,740
(341.4)
11,030
(49.1)
37,230
(165.6)
57,320
(255.0)
119,905
(533.4)
3,620
(16.1)
5,150
(22.9)
6,865
(30.5)
11,440
(50.9)
5,510
(24.5)
9,150
(40.7)
12,200
(54.3)
20,335
(90.5)
6,675
(29.7)
14,300
(63.6)
19,065
(84.8)
31,775
(141.3)
7,910
(35.2)
20,590
(91.6)
27,455
(122.1)
45,755
(203.5)
7,910
(35.2)
26,705
(118.8)
37,365
(166.2)
62,280
(277.0)
9,665
(43.0)
32,625
(145.1)
48,805
(217.1)
81,345
(361.8)
13,510
(60.1)
45,595
(202.8)
70,200
(312.3)
127,100
(565.4)
3,075
(13.7)
10,415
(46.3)
13,945
(62.0)
23,245
(103.4)
7,660
(34.1)
16,035
(71.3)
24,690
(109.8)
41,320
(183.8)
9,280
(41.3)
22,415
(99.7)
34,505
(153.5)
64,565
(287.2)
11,000
(48.9)
29,460
(131.0)
45,360
(201.8)
92,975
(413.6)
11,000
(48.9)
37,125
(165.1)
57,160
(254.3)
122,990
(547.1)
13,440
(59.8)
45,360
(201.8)
69,835
(310.6)
150,265
(668.4)
18,785
(83.6)
63,395
(282.0)
97,600
(434.1)
210,000
(934.1)
3,370
(15.0)
10,460
(46.5)
13,945
(62.0)
23,245
(103.4)
8,395
(37.3)
17,570
(78.2)
24,795
(110.3)
41,320
(183.8)
10,165
(45.2)
24,550
(109.2)
37,800
(168.1)
64,565
(287.2)
12,050
(53.6)
32,275
(143.6)
49,690
(221.0)
92,975
(413.6)
12,050
(53.6)
40,670
(180.9)
62,615
(278.5)
126,545
(562.9)
14,725
(65.5)
49,690
(221.0)
76,500
(340.3)
164,605
(732.2)
20,575
(91.5)
69,445
(308.9)
106,915
(475.6)
230,045
(1023.3)
3,680
(16.4)
10,460
(46.5)
13,945
(62.0)
23,245
(103.4)
9,690
(43.1)
18,595
(82.7)
24,795
(110.3)
41,320
(183.8)
11,740
(52.2)
28,350
(126.1)
38,740
(172.3)
64,565
(287.2)
13,915
(61.9)
37,265
(165.8)
55,785
(248.1)
92,975
(413.6)
13,915
(61.9)
46,960
(208.9)
72,300
(321.6)
126,545
(562.9)
17,000
(75.6)
57,375
(255.2)
88,335
(392.9)
165,285
(735.2)
23,760
(105.7)
80,185
(356.7)
123,455
(549.2)
258,260
(1148.8)
3,900
(17.3)
11,085
(49.3)
14,785
(65.8)
24,640
(109.6)
11,870
(52.8)
19,710
(87.7)
26,280
(116.9)
43,800
(194.8)
14,380
(64.0)
30,795
(137.0)
41,065
(182.7)
68,440
(304.4)
17,040
(75.8)
44,350
(197.3)
59,130
(263.0)
98,550
(438.4)
17,040
(75.8)
57,515
(255.8)
80,485
(358.0)
134,140
(596.7)
20,820
(92.6)
70,270
(312.6)
105,120
(467.6)
175,205
(779.3)
29,100
(129.4)
98,205
(436.8)
151,200
(672.6)
273,755
(1217.7)
1
2
3
4
82 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3/8
1/2
5/8
3/4
7/8
1-1/4
Tension Nn or Nr
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
2-3/8
(60)
3-3/8
(86)
4-1/2
(114)
7-1/2
(191)
2-3/4
(70)
4-1/2
(114)
6
(152)
10
(254)
3-1/8
(79)
5-5/8
(143)
7-1/2
(191)
12-1/2
(318)
3-1/2
(89)
6-3/4
(171)
9
(229)
15
(381)
3-1/2
(89)
7-7/8
(200)
10-1/2
(267)
17-1/2
(445)
4
(102)
9
(229)
12
(305)
20
(508)
5
(127)
11-1/4
(286)
15
(381)
25
(635)
1,900
(8.5)
2,700
(12.0)
3,600
(16.0)
5,995
(26.7)
2,520
(11.2)
4,830
(21.5)
6,440
(28.6)
10,730
(47.7)
3,050
(13.6)
7,370
(32.8)
10,120
(45.0)
16,865
(75.0)
3,620
(16.1)
9,690
(43.1)
14,640
(65.1)
24,395
(108.5)
3,620
(16.1)
12,210
(54.3)
16,885
(75.1)
28,140
(125.2)
4,420
(19.7)
14,920
(66.4)
22,150
(98.5)
36,920
(164.2)
6,175
(27.5)
20,850
(92.7)
32,095
(142.8)
58,070
(258.3)
1,900
(8.5)
2,700
(12.0)
3,600
(16.0)
5,995
(26.7)
2,760
(12.3)
4,830
(21.5)
6,440
(28.6)
10,730
(47.7)
3,345
(14.9)
7,590
(33.8)
10,120
(45.0)
16,865
(75.0)
3,965
(17.6)
10,615
(47.2)
14,640
(65.1)
24,395
(108.5)
3,965
(17.6)
12,665
(56.3)
16,885
(75.1)
28,140
(125.2)
4,840
(21.5)
16,340
(72.7)
22,150
(98.5)
36,920
(164.2)
6,765
(30.1)
22,840
(101.6)
34,840
(155.0)
58,070
(258.3)
1,900
(8.5)
2,700
(12.0)
3,600
(16.0)
5,995
(26.7)
2,950
(13.1)
4,830
(21.5)
6,440
(28.6)
10,730
(47.7)
3,860
(17.2)
7,590
(33.8)
10,120
(45.0)
16,865
(75.0)
4,575
(20.4)
10,980
(48.8)
14,640
(65.1)
24,395
(108.5)
4,575
(20.4)
12,665
(56.3)
16,885
(75.1)
28,140
(125.2)
5,590
(24.9)
16,615
(73.9)
22,150
(98.5)
36,920
(164.2)
7,815
(34.8)
26,130
(116.2)
34,840
(155.0)
58,070
(258.3)
2,015
(9.0)
2,860
(12.7)
3,815
(17.0)
6,355
(28.3)
3,130
(13.9)
5,120
(22.8)
6,825
(30.4)
11,375
(50.6)
4,470
(19.9)
8,045
(35.8)
10,725
(47.7)
17,875
(79.5)
5,605
(24.9)
11,635
(51.8)
15,515
(69.0)
25,860
(115.0)
5,605
(24.9)
13,425
(59.7)
17,900
(79.6)
29,830
(132.7)
6,845
(30.4)
17,610
(78.3)
23,480
(104.4)
39,135
(174.1)
9,570
(42.6)
27,700
(123.2)
36,935
(164.3)
61,555
(273.8)
2,045
(9.1)
5,810
(25.8)
7,750
(34.5)
12,915
(57.4)
5,425
(24.1)
10,400
(46.3)
13,870
(61.7)
23,115
(102.8)
6,575
(29.2)
15,875
(70.6)
21,790
(96.9)
36,320
(161.6)
7,790
(34.7)
20,870
(92.8)
31,530
(140.3)
52,550
(233.8)
7,790
(34.7)
26,300
(117.0)
36,370
(161.8)
60,615
(269.6)
9,520
(42.3)
32,130
(142.9)
47,710
(212.2)
79,520
(353.7)
13,305
(59.2)
44,905
(199.7)
69,135
(307.5)
125,075
(556.4)
2,045
(9.1)
5,810
(25.8)
7,750
(34.5)
12,915
(57.4)
5,945
(26.4)
10,400
(46.3)
13,870
(61.7)
23,115
(102.8)
7,200
(32.0)
16,345
(72.7)
21,790
(96.9)
36,320
(161.6)
8,535
(38.0)
22,860
(101.7)
31,530
(140.3)
52,550
(233.8)
8,535
(38.0)
27,275
(121.3)
36,370
(161.8)
60,615
(269.6)
10,430
(46.4)
35,195
(156.6)
47,710
(212.2)
79,520
(353.7)
14,575
(64.8)
49,190
(218.8)
75,045
(333.8)
125,075
(556.4)
2,045
(9.1)
5,810
(25.8)
7,750
(34.5)
12,915
(57.4)
6,355
(28.3)
10,400
(46.3)
13,870
(61.7)
23,115
(102.8)
8,315
(37.0)
16,345
(72.7)
21,790
(96.9)
36,320
(161.6)
9,855
(43.8)
23,645
(105.2)
31,530
(140.3)
52,550
(233.8)
9,855
(43.8)
27,275
(121.3)
36,370
(161.8)
60,615
(269.6)
12,040
(53.6)
35,785
(159.2)
47,710
(212.2)
79,520
(353.7)
16,830
(74.9)
56,285
(250.4)
75,045
(333.8)
125,075
(556.4)
2,165
(9.6)
6,160
(27.4)
8,215
(36.5)
13,690
(60.9)
6,735
(30.0)
11,025
(49.0)
14,700
(65.4)
24,500
(109.0)
9,625
(42.8)
17,325
(77.1)
23,100
(102.8)
38,500
(171.3)
12,070
(53.7)
25,065
(111.5)
33,420
(148.7)
55,700
(247.8)
12,070
(53.7)
28,910
(128.6)
38,550
(171.5)
64,250
(285.8)
14,750
(65.6)
37,930
(168.7)
50,575
(225.0)
84,290
(374.9)
20,610
(91.7)
59,660
(265.4)
79,545
(353.8)
132,580
(589.7)
3.2.3
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
1
2
3
4
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 83
HAS-E 5
Tensile
Nsa
lb (kN)
Shear
Vsa
lb (kN)
3,655
(16.3)
6,690
(29.8)
10,650
(47.4)
15,765
(70.1)
21,755
(96.8)
28,540
(127.0)
45,670
(203.1)
1,685
(7.5)
3,705
(16.5)
5,900
(26.2)
8,730
(38.8)
12,050
(53.6)
15,805
(70.3)
25,295
(112.5)
Tensile
Nsa
lb (kN)
Shear
Vsa
lb (kN)
7,265
(32.3)
13,300
(59.2)
21,190
(94.3)
31,360
(139.5)
43,285
(192.5)
56,785
(252.6)
90,850
(404.1)
3,150
(14.0)
6,915
(30.8)
11,020
(49.0)
16,305
(72.5)
22,505
(100.1)
29,525
(131.3)
47,240
(210.1)
seis,V4
0.7
0.7
0.7
0.7
0.7
0.7
0.7
Tensile
Nsa
lb (kN)
Shear2
Vsa
lb (kN)
5,040
(22.4)
9,225
(41.0)
14,690
(65.3)
18,480
(82.2)
25,510
(113.5)
33,465
(148.9)
53,540
(238.2)
2,325
(10.3)
5,110
(22.7)
8,135
(36.2)
10,235
(45.5)
14,125
(62.8)
18,535
(82.4)
29,655
(131.9)
seis,V4
0.7
0.7
0.7
0.7
0.7
0.7
0.7
seis,V4
0.7
0.7
0.7
0.7
0.7
0.7
0.7
84 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
1-7/8 (48)
2
(51)
3
(76)
3-5/8 (92)
4
(102)
4-5/8 (117)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
8
(203)
8-3/4 (222)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
24
(610)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
2-3/8
(60)
n/a
0.59
0.60
0.65
0.68
0.69
0.72
0.74
0.78
0.79
0.84
0.89
0.93
0.94
0.99
1.00
3-3/8
(86)
n/a
0.59
0.60
0.65
0.68
0.69
0.72
0.74
0.78
0.79
0.84
0.89
0.93
0.94
0.99
1.00
4-1/2
(114)
n/a
0.57
0.57
0.61
0.63
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.82
0.83
0.87
0.91
0.94
1.00
7-1/2
(191)
n/a
0.54
0.54
0.57
0.58
0.59
0.60
0.61
0.63
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.81
0.86
0.90
1.00
3-3/8
(86)
0.30
0.31
0.32
0.39
0.44
0.47
0.52
0.55
0.63
0.66
0.77
0.88
0.96
0.99
1.00
4-1/2
(114)
0.22
0.23
0.23
0.28
0.32
0.34
0.38
0.40
0.46
0.48
0.56
0.64
0.70
0.72
0.80
0.88
0.96
1.00
7-1/2
(191)
0.13
0.13
0.14
0.17
0.19
0.20
0.22
0.23
0.27
0.28
0.32
0.37
0.41
0.42
0.46
0.51
0.56
0.65
0.74
0.83
1.00
Spacing factor in
shear4
AV
2-3/8
(60)
n/a
0.57
0.57
0.61
0.63
0.64
0.66
0.68
0.70
0.71
0.75
0.79
0.81
0.82
0.86
0.89
0.93
1.00
1.00
3-3/8
(86)
n/a
0.53
0.53
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.68
0.70
0.73
0.76
0.79
0.89
0.99
1.00
4-1/2
(114)
n/a
0.53
0.53
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.61
0.62
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.82
0.90
0.98
1.00
7-1/2
(191)
n/a
0.52
0.52
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.60
0.61
0.63
0.65
0.67
0.73
0.79
0.84
0.96
To edge
RV
Toward edge
RV
2-3/8
(60)
0.23
0.25
0.28
0.51
0.68
0.79
0.98
1.00
3-3/8
(86)
0.07
0.08
0.09
0.16
0.21
0.24
0.30
0.34
0.42
0.45
0.57
0.69
0.79
0.83
0.97
1.00
4-1/2
(114)
0.05
0.06
0.06
0.12
0.16
0.18
0.23
0.26
0.31
0.34
0.42
0.52
0.59
0.62
0.72
0.83
0.95
1.00
7-1/2
(191)
0.03
0.04
0.04
0.07
0.09
0.11
0.14
0.15
0.19
0.20
0.25
0.31
0.35
0.37
0.43
0.50
0.57
0.72
0.88
1.00
2-3/8
(60)
0.44
0.38
0.40
0.51
0.60
0.66
0.76
0.82
0.95
0.99
1.00
3-3/8
(86)
0.14
0.16
0.17
0.32
0.42
0.47
0.52
0.55
0.63
0.66
0.77
0.88
0.96
0.99
1.00
4-1/2
(114)
0.11
0.12
0.13
0.24
0.32
0.37
0.41
0.43
0.48
0.49
0.56
0.64
0.70
0.72
0.80
0.88
0.96
1.00
Concrete thickness
factor in shear5
HV
7-1/2
(191)
0.06
0.07
0.08
0.14
0.19
0.22
0.27
0.31
0.34
0.34
0.37
0.41
0.43
0.44
0.48
0.51
0.56
0.65
0.74
0.83
1.00
2-3/8
(60)
n/a
n/a
n/a
n/a
0.72
0.75
0.81
0.84
0.91
0.92
1.00
1.00
3-3/8
(86)
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.61
0.63
0.68
0.72
0.76
0.77
0.81
0.85
0.88
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.57
0.61
0.66
0.69
0.69
0.73
0.77
0.80
0.87
0.93
0.98
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.59
0.62
0.65
0.68
0.73
0.78
0.83
0.96
1.00
Table 43 - Load adjustment factors for 3/8-in. diameter threaded rods in cracked concrete1,2,3
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
1-7/8 (48)
2
(51)
3
(76)
3-5/8 (92)
4
(102)
4-5/8 (117)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
8
(203)
8-3/4 (222)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
24
(610)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
2-3/8
(60)
n/a
0.59
0.60
0.65
0.68
0.69
0.72
0.74
0.78
0.79
0.84
0.89
0.93
0.94
0.99
1.00
3-3/8
(86)
n/a
0.59
0.60
0.65
0.68
0.69
0.72
0.74
0.78
0.79
0.84
0.89
0.93
0.94
0.99
1.00
4-1/2
(114)
n/a
0.57
0.57
0.61
0.63
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.82
0.83
0.87
0.91
0.94
1.00
7-1/2
(191)
n/a
0.54
0.54
0.57
0.58
0.59
0.60
0.61
0.63
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.81
0.86
0.90
1.00
3-3/8
(86)
0.54
0.55
0.57
0.69
0.78
0.83
0.92
0.98
1.00
4-1/2
(114)
0.49
0.50
0.51
0.60
0.66
0.70
0.76
0.80
0.88
0.91
1.00
7-1/2
(191)
0.43
0.44
0.44
0.49
0.53
0.55
0.58
0.60
0.64
0.66
0.72
0.78
0.83
0.85
0.91
0.98
1.00
Spacing factor in
shear4
AV
2-3/8
(60)
n/a
0.57
0.57
0.61
0.64
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.83
0.84
0.87
0.91
0.95
1.00
3-3/8
(86)
n/a
0.54
0.54
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.67
0.67
0.69
0.71
0.73
0.77
0.81
0.85
0.96
1.00
4-1/2
(114)
n/a
0.53
0.53
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.64
0.66
0.67
0.69
0.72
0.75
0.79
0.88
0.98
1.00
7-1/2
(191)
n/a
0.52
0.52
0.53
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.68
0.70
0.77
0.84
0.91
1.00
To edge
RV
Toward edge
RV
2-3/8
(60)
0.25
0.27
0.30
0.55
0.73
0.85
1.00
3-3/8
(86)
0.09
0.10
0.11
0.20
0.27
0.31
0.39
0.44
0.54
0.58
0.72
0.89
1.00
4-1/2
(114)
0.07
0.08
0.08
0.15
0.20
0.23
0.29
0.33
0.40
0.43
0.54
0.66
0.76
0.79
0.93
1.00
7-1/2
(191)
0.04
0.05
0.05
0.09
0.12
0.14
0.18
0.20
0.24
0.26
0.33
0.40
0.46
0.48
0.56
0.64
0.73
0.92
1.00
2-3/8
(60)
0.49
0.55
0.60
0.88
1.00
3-3/8
(86)
0.18
0.20
0.22
0.41
0.54
0.63
0.78
0.87
1.00
3.2.4
3.2.4
3.2.4
3.2.3
4-1/2
(114)
0.14
0.15
0.17
0.30
0.41
0.47
0.58
0.66
0.81
0.86
1.00
Concrete thickness
factor in shear5
HV
7-1/2
(191)
0.08
0.09
0.10
0.18
0.24
0.28
0.35
0.39
0.49
0.52
0.65
0.78
0.83
0.85
0.91
0.98
1.00
2-3/8
(60)
n/a
n/a
n/a
n/a
0.74
0.77
0.83
0.86
0.93
0.95
1.00
3-3/8
(86)
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.62
0.66
0.68
0.73
0.78
0.82
0.83
0.88
0.92
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.62
0.67
0.71
0.74
0.76
0.80
0.84
0.87
0.94
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.64
0.67
0.70
0.74
0.79
0.85
0.90
1.00
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 85
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
2-1/2 (64)
3
(76)
4
(102)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
7-1/4 (184)
8
(203)
9
(229)
10
(254)
11-1/4 (286)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
2-3/4
(70)
n/a
0.59
0.61
0.65
0.68
0.71
0.72
0.76
0.76
0.79
0.83
0.86
0.91
0.94
1.00
4-1/2
(114)
n/a
0.59
0.61
0.65
0.68
0.71
0.72
0.76
0.76
0.79
0.83
0.86
0.91
0.94
1.00
6
(152)
n/a
0.57
0.58
0.61
0.64
0.66
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
n/a 0.34 0.26 0.20
0.54 0.40 0.30 0.22
0.55 0.45 0.32 0.24
0.57 0.56 0.38 0.28
0.58 0.69 0.43 0.32
0.60 0.80 0.48 0.35
0.60 0.83 0.49 0.36
0.62 0.97 0.56 0.41
0.62 1.00 0.58 0.43
0.63
0.64 0.47
0.65
0.72 0.53
0.67
0.80 0.59
0.69
0.90 0.66
0.70
0.96 0.70
0.73
1.00 0.82
0.77
0.94
0.80
1.00
0.83
0.87
0.90
1.00
Spacing factor in
shear4
AV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
0.11 n/a
n/a
n/a
0.13 0.55 0.53 0.53
0.14 0.56 0.54 0.53
0.16 0.58 0.55 0.54
0.19 0.60 0.57 0.55
0.21 0.62 0.58 0.56
0.21 0.63 0.58 0.56
0.24 0.65 0.59 0.57
0.25 0.65 0.60 0.57
0.27 0.67 0.61 0.58
0.31 0.69 0.62 0.59
0.34 0.71 0.63 0.60
0.39 0.74 0.65 0.61
0.41 0.75 0.66 0.62
0.48 0.79 0.69 0.64
0.55 0.83 0.72 0.66
0.62 0.88 0.74 0.68
0.69 0.92 0.77 0.70
0.76 0.96 0.80 0.72
0.82 1.00 0.82 0.74
1.00
0.90 0.80
0.98 0.86
1.00 0.98
Toward edge
RV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
n/a 0.10 0.05 0.03
0.52 0.18 0.09 0.06
0.52 0.23 0.12 0.08
0.53 0.36 0.18 0.12
0.54 0.50 0.26 0.17
0.54 0.61 0.32 0.21
0.54 0.65 0.34 0.22
0.55 0.82 0.42 0.28
0.55 0.87 0.45 0.29
0.56 1.00 0.52 0.34
0.56
0.62 0.40
0.57
0.72 0.47
0.58
0.86 0.56
0.59
0.95 0.62
0.60
1.00 0.78
0.61
0.95
0.63
1.00
0.64
0.66
0.67
0.71
0.76
0.84
To edge
RV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
0.02 0.21 0.11 0.07
0.04 0.35 0.18 0.12
0.05 0.45 0.24 0.15
0.07 0.56 0.37 0.24
0.10 0.69 0.43 0.33
0.12 0.80 0.48 0.39
0.13 0.83 0.49 0.40
0.16 0.97 0.56 0.44
0.17 1.00 0.58 0.45
0.20
0.64 0.48
0.24
0.72 0.53
0.28
0.80 0.59
0.34
0.90 0.66
0.37
0.96 0.70
0.47
1.00 0.82
0.57
0.94
0.68
1.00
0.80
0.92
1.00
Concrete thickness
factor in shear5
HV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
0.04 n/a
n/a
n/a
0.07 n/a
n/a
n/a
0.09 n/a
n/a
n/a
0.14 0.58 n/a
n/a
0.20 0.65 n/a
n/a
0.25 0.69 0.56 n/a
0.26 0.71 0.57 n/a
0.32 0.77 0.61 n/a
0.32 0.78 0.62 0.54
0.34 0.82 0.66 0.57
0.36 0.87 0.70 0.60
0.39 0.92 0.73 0.64
0.42 0.97 0.78 0.67
0.44 1.00 0.80 0.70
0.49
0.87 0.75
0.55
0.93 0.80
0.62
0.98 0.85
0.69
1.00 0.90
0.76
0.94
0.82
0.98
1.00
1.00
10
(254)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.63
0.68
0.72
0.76
0.79
0.83
0.93
1.00
Table 45 - Load adjustment factors for 1/2-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
1/2-in.
cracked
concrete
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
2-1/2 (64)
3
(76)
4
(102)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
7-1/4 (184)
8
(203)
9
(229)
10
(254)
11-1/4 (286)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
2-3/4
(70)
n/a
0.59
0.61
0.65
0.68
0.71
0.72
0.76
0.76
0.79
0.83
0.86
0.91
0.94
1.00
4-1/2
(114)
n/a
0.59
0.61
0.65
0.68
0.71
0.72
0.76
0.76
0.79
0.83
0.86
0.91
0.94
1.00
6
(152)
n/a
0.57
0.58
0.61
0.64
0.66
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
n/a 0.49 0.49 0.45
0.54 0.55 0.55 0.50
0.55 0.60 0.60 0.53
0.57 0.69 0.69 0.60
0.58 0.79 0.79 0.67
0.60 0.88 0.88 0.73
0.60 0.90 0.90 0.75
0.62 1.00 1.00 0.83
0.62
0.85
0.63
0.91
0.65
1.00
0.67
0.69
0.70
0.73
0.77
0.80
0.83
0.87
0.90
1.00
Spacing factor in
shear4
AV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
0.41 n/a
n/a
n/a
0.44 0.55 0.54 0.53
0.46 0.56 0.54 0.54
0.49 0.58 0.56 0.55
0.53 0.61 0.57 0.56
0.56 0.62 0.58 0.57
0.57 0.63 0.59 0.57
0.62 0.65 0.60 0.58
0.63 0.65 0.60 0.59
0.66 0.67 0.61 0.59
0.70 0.69 0.63 0.61
0.75 0.71 0.64 0.62
0.81 0.74 0.66 0.63
0.85 0.75 0.67 0.64
0.95 0.79 0.70 0.67
1.00 0.84 0.73 0.69
0.88 0.76 0.71
0.92 0.79 0.74
0.96 0.82 0.76
1.00 0.84 0.78
0.93 0.86
1.00 0.93
1.00
Toward edge
RV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
n/a 0.10 0.06 0.04
0.52 0.18 0.10 0.07
0.53 0.23 0.13 0.10
0.53 0.36 0.20 0.15
0.54 0.50 0.28 0.21
0.55 0.62 0.35 0.26
0.55 0.66 0.37 0.28
0.56 0.83 0.47 0.35
0.56 0.88 0.49 0.37
0.57 1.00 0.57 0.43
0.58
0.68 0.51
0.58
0.80 0.60
0.59
0.95 0.71
0.60
1.00 0.79
0.62
0.99
0.63
1.00
0.65
0.67
0.69
0.70
0.75
0.80
0.90
To edge
RV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
0.03 0.21 0.12 0.09
0.04 0.35 0.20 0.15
0.06 0.47 0.26 0.20
0.09 0.72 0.40 0.30
0.13 1.00 0.56 0.42
0.16
0.70 0.52
0.17
0.74 0.56
0.21
0.94 0.70
0.22
0.99 0.74
0.26
1.00 0.86
0.31
1.00
0.36
0.43
0.47
0.60
0.73
0.87
1.00
Concrete thickness
factor in shear5
HV
10 2-3/4 4-1/2
6
(254) (70) (114) (152)
0.05 n/a
n/a
n/a
0.09 n/a
n/a
n/a
0.12 n/a
n/a
n/a
0.18 0.58 n/a
n/a
0.25 0.65 n/a
n/a
0.31 0.70 0.57 n/a
0.33 0.71 0.59 n/a
0.42 0.77 0.63 n/a
0.44 0.78 0.64 0.59
0.51 0.82 0.68 0.62
0.61 0.87 0.72 0.65
0.72 0.92 0.76 0.69
0.81 0.97 0.80 0.73
0.85 1.00 0.83 0.75
0.95
0.90 0.81
1.00
0.96 0.87
1.00 0.92
0.97
1.00
10
(254)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.64
0.69
0.73
0.78
0.82
0.86
0.90
1.00
86 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
3-1/8 (79)
4
(102)
4-5/8 (117)
5
(127)
6
(152)
7
(178)
7-1/8 (181)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
3-1/8
(79)
n/a
0.59
0.62
0.63
0.65
0.68
0.70
0.71
0.73
0.76
0.79
0.82
0.85
0.91
0.97
1.00
5-5/8
(143)
n/a
0.59
0.62
0.63
0.65
0.68
0.70
0.71
0.73
0.76
0.79
0.82
0.85
0.91
0.97
1.00
7-1/2
(191)
n/a
0.57
0.59
0.60
0.61
0.63
0.66
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.86
0.90
0.94
0.99
1.00
12-1/2
(318)
n/a
0.54
0.55
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.79
0.82
0.85
0.87
0.90
0.98
1.00
5-5/8
(143)
0.25
0.30
0.33
0.36
0.38
0.42
0.47
0.47
0.52
0.57
0.64
0.70
0.77
0.89
1.00
7-1/2
(191)
0.18
0.22
0.25
0.27
0.28
0.31
0.34
0.35
0.38
0.42
0.47
0.52
0.56
0.66
0.75
0.84
0.94
1.00
12-1/2
(318)
0.11
0.13
0.14
0.16
0.16
0.18
0.20
0.20
0.22
0.25
0.27
0.30
0.33
0.38
0.44
0.49
0.55
0.60
0.66
0.71
0.77
0.82
0.99
1.00
Spacing factor in
shear4
AV
3-1/8
(79)
n/a
0.56
0.58
0.59
0.60
0.62
0.64
0.64
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.85
0.89
0.93
0.97
1.00
5-5/8
(143)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.64
0.66
0.69
0.71
0.73
0.75
0.78
0.80
0.82
0.85
0.92
1.00
7-1/2
(191)
n/a
0.53
0.53
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.62
0.64
0.66
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
12-1/2
(318)
n/a
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.71
0.77
To edge
RV
Toward edge
RV
3-1/8
(79)
0.09
0.22
0.32
0.40
0.45
0.59
0.75
0.77
0.91
1.00
5-5/8
(143)
0.04
0.10
0.15
0.18
0.21
0.27
0.34
0.35
0.41
0.50
0.58
0.67
0.76
0.96
1.00
7-1/2
(191)
0.03
0.07
0.10
0.12
0.13
0.18
0.22
0.23
0.27
0.32
0.38
0.43
0.50
0.62
0.76
0.91
1.00
12-1/2
(318)
0.01
0.04
0.05
0.06
0.07
0.09
0.12
0.12
0.14
0.17
0.20
0.23
0.26
0.33
0.41
0.49
0.57
0.66
0.75
0.84
0.94
1.00
3-1/8
(79)
0.19
0.44
0.52
0.59
0.63
0.76
0.88
0.90
1.00
5-5/8
(143)
0.08
0.20
0.29
0.36
0.38
0.42
0.47
0.47
0.52
0.57
0.64
0.70
0.77
0.89
1.00
7-1/2
(191)
0.06
0.13
0.19
0.24
0.27
0.35
0.38
0.38
0.41
0.45
0.48
0.52
0.56
0.66
0.75
0.84
0.94
1.00
Concrete thickness
factor in shear5
HV
12-1/2
(318)
0.03
0.07
0.10
0.13
0.14
0.19
0.24
0.24
0.29
0.32
0.34
0.36
0.38
0.41
0.46
0.50
0.55
0.60
0.66
0.71
0.77
0.82
0.99
1.00
3-1/8
(79)
n/a
n/a
n/a
0.60
0.63
0.69
0.74
0.75
0.79
0.84
0.89
0.93
0.97
1.00
5-5/8
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.61
0.65
0.68
0.71
0.75
0.81
0.86
0.91
0.96
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.59
0.62
0.65
0.70
0.75
0.79
0.83
0.87
0.91
0.95
0.99
1.00
12-1/2
(318)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.61
0.64
0.68
0.71
0.74
0.77
0.80
0.83
0.91
1.00
Table 47 - Load adjustment factors for 5/8-in. diameter threaded rods in cracked concrete1,2,3
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
3-1/8 (79)
4
(102)
4-5/8 (117)
5
(127)
6
(152)
7
(178)
7-1/8 (181)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
3-1/8
(79)
n/a
0.59
0.62
0.63
0.65
0.68
0.70
0.71
0.73
0.76
0.79
0.82
0.85
0.91
0.97
1.00
5-5/8
(143)
n/a
0.59
0.62
0.63
0.65
0.68
0.70
0.71
0.73
0.76
0.79
0.82
0.85
0.91
0.97
1.00
7-1/2
(191)
n/a
0.57
0.59
0.60
0.61
0.63
0.66
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.86
0.90
0.94
0.99
1.00
12-1/2
(318)
n/a
0.54
0.55
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.79
0.82
0.85
0.87
0.90
0.98
1.00
5-5/8
(143)
0.46
0.55
0.62
0.66
0.69
0.77
0.86
0.87
0.95
1.00
7-1/2
(191)
0.43
0.50
0.55
0.58
0.60
0.66
0.72
0.73
0.78
0.85
0.91
0.98
1.00
12-1/2
(318)
0.40
0.44
0.46
0.48
0.49
0.53
0.56
0.56
0.59
0.62
0.66
0.69
0.73
0.81
0.89
0.97
1.00
Spacing factor in
shear4
AV
3-1/8
(79)
n/a
0.56
0.58
0.59
0.60
0.62
0.64
0.64
0.66
0.68
0.70
0.72
0.74
0.78
0.82
0.85
0.89
0.93
0.97
1.00
5-5/8
(143)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.64
0.66
0.69
0.71
0.73
0.76
0.78
0.80
0.83
0.85
0.92
1.00
7-1/2
(191)
n/a
0.53
0.54
0.54
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.73
0.75
0.76
0.78
0.84
0.95
12-1/2
(318)
n/a
0.52
0.53
0.53
0.53
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.61
0.62
0.63
0.65
0.66
0.67
0.69
0.70
0.74
0.82
To edge
RV
Toward edge
RV
3-1/8
(79)
0.09
0.22
0.33
0.40
0.45
0.60
0.75
0.77
0.92
1.00
5-5/8
(143)
0.04
0.10
0.15
0.18
0.21
0.27
0.34
0.35
0.42
0.50
0.58
0.67
0.77
0.97
1.00
7-1/2
(191)
0.03
0.07
0.11
0.13
0.15
0.20
0.25
0.26
0.30
0.36
0.43
0.49
0.56
0.71
0.86
1.00
12-1/2
(318)
0.02
0.04
0.06
0.08
0.09
0.12
0.15
0.15
0.18
0.22
0.26
0.29
0.34
0.42
0.52
0.62
0.72
0.83
0.95
1.00
3-1/8
(79)
0.19
0.45
0.65
0.81
0.91
1.00
5-5/8
(143)
0.09
0.20
0.30
0.37
0.41
0.54
0.68
0.70
0.84
1.00
1.00
3.2.4
3.2.4
3.2.4
3.2.3
7-1/2
(191)
0.06
0.15
0.22
0.27
0.30
0.40
0.50
0.51
0.61
0.73
0.85
0.98
1.00
Concrete thickness
factor in shear5
HV
12-1/2
(318)
0.04
0.09
0.13
0.16
0.18
0.24
0.30
0.31
0.37
0.44
0.51
0.59
0.67
0.81
0.89
0.97
1.00
3-1/8
(79)
n/a
n/a
n/a
0.60
0.63
0.69
0.74
0.75
0.79
0.84
0.89
0.93
0.97
1.00
5-5/8
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.65
0.68
0.72
0.75
0.81
0.86
0.92
0.97
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.64
0.67
0.73
0.78
0.82
0.87
0.91
0.95
0.99
1.00
12-1/2
(318)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.66
0.70
0.73
0.77
0.80
0.84
0.87
0.90
0.98
1.00
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 87
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
3-3/4 (95)
4
(102)
5
(127)
5-1/4 (133)
6
(152)
7
(178)
8
(203)
8-1/2 (216)
9
(229)
10
(254)
10-3/4 (273)
12
(305)
14
(356)
16
(406)
16-3/4 (425)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
3-1/2
(89)
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.69
0.71
0.72
0.74
0.76
0.79
0.84
0.89
0.91
0.94
0.99
1.00
6-3/4
(171)
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.69
0.71
0.72
0.74
0.76
0.79
0.84
0.89
0.91
0.94
0.99
1.00
9
(229)
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.69
0.70
0.72
0.76
0.80
0.81
0.83
0.87
0.91
0.94
0.98
1.00
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
n/a 0.33 0.24 0.18
0.54 0.49 0.30 0.22
0.54 0.51 0.31 0.23
0.56 0.60 0.34 0.25
0.56 0.63 0.35 0.26
0.57 0.69 0.38 0.28
0.58 0.76 0.41 0.30
0.59 0.83 0.45 0.33
0.59 0.87 0.47 0.35
0.60 0.90 0.49 0.36
0.61 0.98 0.53 0.39
0.62 1.00 0.57 0.42
0.63
0.64 0.47
0.66
0.74 0.55
0.68
0.85 0.62
0.69
0.89 0.65
0.70
0.95 0.70
0.72
1.00 0.78
0.74
0.86
0.77
0.93
0.79
1.00
0.81
0.83
0.90
1.00
Spacing factor in
shear4
AV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
0.10 n/a
n/a
n/a
0.13 0.57 0.54 0.53
0.13 0.57 0.54 0.53
0.15 0.59 0.55 0.54
0.15 0.60 0.55 0.54
0.16 0.61 0.56 0.55
0.18 0.63 0.57 0.55
0.19 0.65 0.58 0.56
0.20 0.66 0.59 0.56
0.21 0.67 0.59 0.57
0.23 0.68 0.60 0.58
0.25 0.70 0.61 0.58
0.27 0.72 0.62 0.59
0.32 0.76 0.64 0.61
0.37 0.79 0.66 0.62
0.38 0.81 0.67 0.63
0.41 0.83 0.68 0.64
0.46 0.87 0.70 0.65
0.50 0.91 0.72 0.67
0.55 0.94 0.74 0.68
0.59 0.98 0.76 0.70
0.64 1.00 0.78 0.71
0.68
0.80 0.73
0.82
0.86 0.77
1.00
0.99 0.86
Toward edge
RV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
n/a 0.09 0.03 0.02
0.52 0.27 0.11 0.07
0.52 0.29 0.12 0.08
0.52 0.41 0.17 0.11
0.52 0.44 0.18 0.12
0.53 0.54 0.22 0.14
0.53 0.68 0.28 0.18
0.54 0.83 0.34 0.22
0.54 0.91 0.37 0.24
0.54 0.99 0.40 0.26
0.55 1.00 0.47 0.31
0.55
0.53 0.34
0.56
0.62 0.40
0.57
0.78 0.51
0.58
0.96 0.62
0.58
1.00 0.67
0.58
0.74
0.59
0.87
0.60
1.00
0.61
0.62
0.63
0.64
0.67
0.73
To edge
RV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
0.01 0.17 0.07 0.05
0.03 0.49 0.22 0.14
0.04 0.51 0.24 0.16
0.05 0.60 0.33 0.22
0.06 0.63 0.35 0.23
0.07 0.72 0.38 0.29
0.09 0.84 0.41 0.34
0.11 0.96 0.45 0.37
0.12 1.00 0.47 0.38
0.13
0.49 0.39
0.15
0.53 0.42
0.17
0.57 0.44
0.20
0.64 0.48
0.25
0.74 0.55
0.30
0.85 0.62
0.33
0.89 0.65
0.36
0.95 0.70
0.42
1.00 0.78
0.49
0.86
0.56
0.93
0.63
1.00
0.70
0.78
1.00
Concrete thickness
factor in shear5
HV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
0.02 n/a
n/a
n/a
0.07 n/a
n/a
n/a
0.08 n/a
n/a
n/a
0.11 n/a
n/a
n/a
0.11 0.62 n/a
n/a
0.14 0.66 n/a
n/a
0.18 0.72 n/a
n/a
0.21 0.77 n/a
n/a
0.24 0.79 0.59 n/a
0.26 0.81 0.60 n/a
0.30 0.86 0.64 n/a
0.32 0.89 0.66 0.57
0.34 0.94 0.70 0.60
0.37 1.00 0.75 0.65
0.40
0.80 0.70
0.41
0.82 0.71
0.43
0.85 0.74
0.47
0.90 0.78
0.50
0.94 0.82
0.55
0.99 0.85
0.59
1.00 0.89
0.64
0.92
0.68
0.95
0.82
1.00
1.00
15
(381)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.58
0.61
0.64
0.67
0.70
0.73
0.75
0.82
0.95
Table 49 - Load adjustment factors for 3/4-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
3/4-in.
cracked
concrete
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
3-3/4 (95)
4
(102)
5
(127)
5-1/4 (133)
6
(152)
7
(178)
8
(203)
8-1/2 (216)
9
(229)
10
(254)
10-3/4 (273)
12
(305)
14
(356)
16
(406)
16-3/4 (425)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
3-1/2
(89)
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.69
0.71
0.72
0.74
0.76
0.79
0.84
0.89
0.91
0.94
0.99
1.00
6-3/4
(171)
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.69
0.71
0.72
0.74
0.76
0.79
0.84
0.89
0.91
0.94
0.99
1.00
9
(229)
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.69
0.70
0.72
0.76
0.80
0.81
0.83
0.87
0.91
0.94
0.98
1.00
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
n/a 0.44 0.44 0.42
0.54 0.55 0.55 0.50
0.54 0.57 0.57 0.51
0.56 0.63 0.63 0.56
0.56 0.64 0.64 0.57
0.57 0.69 0.69 0.60
0.58 0.76 0.76 0.65
0.59 0.83 0.83 0.70
0.59 0.87 0.87 0.72
0.60 0.90 0.90 0.75
0.61 0.98 0.98 0.80
0.62 1.00 1.00 0.84
0.63
0.91
0.66
1.00
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
Spacing factor in
shear4
AV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
0.39 n/a
n/a
n/a
0.44 0.57 0.54 0.53
0.44 0.57 0.54 0.53
0.47 0.59 0.55 0.54
0.47 0.60 0.55 0.54
0.49 0.61 0.56 0.55
0.52 0.63 0.57 0.55
0.55 0.65 0.58 0.56
0.56 0.66 0.59 0.57
0.57 0.67 0.59 0.57
0.60 0.69 0.60 0.58
0.62 0.70 0.61 0.58
0.66 0.72 0.62 0.59
0.72 0.76 0.64 0.61
0.78 0.80 0.66 0.62
0.81 0.81 0.67 0.63
0.85 0.83 0.68 0.64
0.91 0.87 0.70 0.65
0.98 0.91 0.72 0.67
1.00 0.94 0.74 0.69
0.98 0.76 0.70
1.00 0.79 0.72
0.81 0.73
0.87 0.78
0.99 0.87
Toward edge
RV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
n/a 0.09 0.03 0.02
0.52 0.27 0.11 0.07
0.52 0.30 0.12 0.08
0.53 0.41 0.17 0.11
0.53 0.45 0.18 0.12
0.53 0.54 0.22 0.15
0.54 0.69 0.28 0.19
0.54 0.84 0.34 0.23
0.55 0.92 0.37 0.25
0.55 1.00 0.41 0.27
0.55
0.48 0.32
0.56
0.53 0.35
0.57
0.63 0.42
0.58
0.79 0.52
0.59
0.97 0.64
0.59
1.00 0.68
0.60
0.76
0.61
0.89
0.62
1.00
0.63
0.64
0.65
0.66
0.70
0.76
To edge
RV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
0.01 0.17 0.07 0.05
0.04 0.54 0.22 0.15
0.05 0.59 0.24 0.16
0.07 0.83 0.34 0.22
0.07 0.89 0.36 0.24
0.09 1.00 0.44 0.29
0.11
0.56 0.37
0.14
0.68 0.45
0.15
0.75 0.50
0.16
0.82 0.54
0.19
0.95 0.63
0.21
1.00 0.70
0.25
0.83
0.31
1.00
0.38
0.41
0.46
0.54
0.62
0.70
0.79
0.89
0.99
1.00
Concrete thickness
factor in shear5
HV
15 3-1/2 6-3/4
9
(381) (89) (171) (229)
0.03 n/a
n/a
n/a
0.09 n/a
n/a
n/a
0.10 n/a
n/a
n/a
0.13 n/a
n/a
n/a
0.14 0.62 n/a
n/a
0.18 0.67 n/a
n/a
0.22 0.72 n/a
n/a
0.27 0.77 n/a
n/a
0.30 0.79 0.59 n/a
0.32 0.82 0.61 n/a
0.38 0.86 0.64 n/a
0.42 0.89 0.66 0.58
0.50 0.94 0.70 0.61
0.63 1.00 0.76 0.66
0.77
0.81 0.70
0.81
0.83 0.72
0.85
0.86 0.75
0.91
0.90 0.79
0.98
0.95 0.82
1.00
0.99 0.86
1.00 0.90
0.93
0.96
1.00
15
(381)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.63
0.66
0.70
0.73
0.76
0.78
0.81
0.89
1.00
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
4-3/8 (111)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
9-7/8 (251)
10
(254)
11
(279)
12
(305)
12-1/2 (318)
14
(356)
16
(406)
18
(457)
19-1/2 (495)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
3-1/2
(89)
n/a
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.71
0.73
0.75
0.76
0.79
0.83
0.88
0.91
0.92
0.96
1.00
7-7/8
(200)
n/a
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.71
0.73
0.75
0.76
0.79
0.83
0.88
0.91
0.92
0.96
1.00
10-1/2
(267)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.66
0.66
0.67
0.69
0.70
0.72
0.75
0.79
0.81
0.82
0.85
0.88
0.91
0.94
0.98
1.00
17-1/2
(445)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.75
0.77
0.79
0.84
0.96
7-7/8
(200)
0.23
0.30
0.32
0.33
0.34
0.37
0.41
0.44
0.47
0.47
0.51
0.54
0.57
0.63
0.73
0.82
0.88
0.91
1.00
1.00
10-1/2
(267)
0.17
0.22
0.23
0.24
0.26
0.28
0.30
0.32
0.35
0.35
0.37
0.40
0.42
0.47
0.53
0.60
0.65
0.67
0.73
0.80
0.87
0.93
1.00
17-1/2
(445)
0.10
0.13
0.14
0.14
0.15
0.16
0.18
0.19
0.20
0.20
0.22
0.23
0.24
0.27
0.31
0.35
0.38
0.39
0.43
0.47
0.51
0.55
0.59
0.70
0.94
Spacing factor in
shear4
AV
3-1/2
(89)
n/a
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.74
0.77
0.80
0.84
0.87
0.88
0.92
0.96
0.99
1.00
7-7/8
(200)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.67
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
10-1/2
(267)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.63
0.64
0.66
0.67
0.68
0.70
0.73
0.81
17-1/2
(445)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.64
0.69
To edge
RV
Toward edge
RV
3-1/2
(89)
0.09
0.35
0.43
0.50
0.57
0.71
0.87
1.00
7-7/8
(200)
0.03
0.11
0.13
0.15
0.17
0.22
0.27
0.32
0.37
0.38
0.43
0.49
0.52
0.62
0.76
0.91
1.00
10-1/2
(267)
0.02
0.07
0.09
0.10
0.11
0.14
0.17
0.21
0.24
0.24
0.28
0.32
0.34
0.40
0.49
0.59
0.66
0.69
0.80
0.91
1.00
17-1/2
(445)
0.01
0.03
0.04
0.05
0.05
0.07
0.08
0.10
0.11
0.11
0.13
0.15
0.16
0.19
0.23
0.27
0.31
0.32
0.37
0.42
0.48
0.53
0.59
0.77
1.00
3-1/2
(89)
0.18
0.60
0.66
0.72
0.78
0.91
1.00
7-7/8
(200)
0.05
0.22
0.27
0.31
0.34
0.37
0.41
0.44
0.47
0.47
0.51
0.54
0.57
0.63
0.73
0.82
0.88
0.91
1.00
10-1/2
(267)
0.04
0.14
0.17
0.20
0.23
0.29
0.34
0.36
0.38
0.38
0.41
0.43
0.44
0.48
0.53
0.60
0.65
0.67
0.73
0.80
0.87
0.93
1.00
Concrete thickness
factor in shear5
HV
17-1/2
(445)
0.02
0.07
0.08
0.09
0.11
0.13
0.16
0.19
0.22
0.23
0.26
0.30
0.32
0.34
0.36
0.39
0.41
0.42
0.45
0.48
0.51
0.55
0.59
0.70
0.94
3-1/2
(89)
n/a
n/a
n/a
0.65
0.68
0.73
0.78
0.83
0.87
0.87
0.91
0.95
0.97
1.00
7-7/8
(200)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.62
0.65
0.66
0.70
0.75
0.79
0.82
0.83
0.87
0.91
0.95
0.99
1.00
10-1/2
(267)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.65
0.68
0.71
0.72
0.76
0.79
0.82
0.85
0.88
0.97
1.00
17-1/2
(445)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.56
0.59
0.61
0.64
0.66
0.68
0.75
0.87
3.2.3
3.2.4
3.2.4
3.2.4
Table 51 - Load adjustment factors for 7/8-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
7/8-in.
cracked
concrete
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
4-3/8 (111)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
9-7/8 (251)
10
(254)
11
(279)
12
(305)
12-1/2 (318)
14
(356)
16
(406)
18
(457)
19-1/2 (495)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
3-1/2
(89)
n/a
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.71
0.73
0.75
0.76
0.79
0.83
0.88
0.91
0.92
0.96
1.00
7-7/8
(200)
n/a
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.71
0.73
0.75
0.76
0.79
0.83
0.88
0.91
0.92
0.96
1.00
10-1/2
(267)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.66
0.66
0.67
0.69
0.70
0.72
0.75
0.79
0.81
0.82
0.85
0.88
0.91
0.94
0.98
1.00
17-1/2
(445)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.75
0.77
0.79
0.84
0.96
7-7/8
(200)
0.43
0.55
0.58
0.61
0.64
0.69
0.75
0.81
0.86
0.87
0.93
1.00
10-1/2
(267)
0.41
0.50
0.52
0.54
0.56
0.60
0.64
0.68
0.72
0.73
0.77
0.82
0.84
0.91
1.00
17-1/2
(445)
0.38
0.44
0.45
0.46
0.47
0.49
0.52
0.54
0.56
0.56
0.59
0.61
0.62
0.66
0.71
0.76
0.80
0.82
0.87
0.93
0.99
1.00
Spacing factor in
shear4
AV
3-1/2
(89)
n/a
0.58
0.60
0.61
0.61
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.74
0.77
0.81
0.84
0.87
0.88
0.92
0.96
1.00
1.00
7-7/8
(200)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.67
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
10-1/2
(267)
n/a
0.53
0.54
0.54
0.54
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.64
0.64
0.65
0.67
0.68
0.70
0.71
0.75
0.84
17-1/2
(445)
n/a
0.52
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.62
0.63
0.64
0.65
0.68
0.74
To edge
RV
Toward edge
RV
3-1/2
(89)
0.09
0.36
0.43
0.50
0.57
0.72
0.88
1.00
7-7/8
(200)
0.03
0.11
0.13
0.15
0.18
0.22
0.27
0.32
0.37
0.38
0.44
0.50
0.53
0.63
0.77
0.91
1.00
10-1/2
(267)
0.02
0.08
0.10
0.11
0.13
0.16
0.20
0.23
0.27
0.27
0.32
0.36
0.38
0.45
0.55
0.66
0.75
0.77
0.89
1.00
17-1/2
(445)
0.01
0.05
0.06
0.07
0.08
0.10
0.12
0.14
0.16
0.16
0.19
0.22
0.23
0.27
0.33
0.40
0.45
0.46
0.54
0.61
0.69
0.77
0.85
1.00
3-1/2
(89)
0.18
0.71
0.87
1.00
7-7/8
(200)
0.06
0.22
0.27
0.31
0.35
0.44
0.54
0.65
0.74
0.76
0.87
1.00
1.00
10-1/2
(267)
0.04
0.16
0.19
0.22
0.25
0.32
0.39
0.47
0.54
0.55
0.63
0.72
0.77
0.91
1.00
Concrete thickness
factor in shear5
HV
17-1/2
(445)
0.02
0.10
0.12
0.13
0.15
0.19
0.24
0.28
0.32
0.33
0.38
0.43
0.46
0.54
0.67
0.76
0.80
0.82
0.87
0.93
0.99
1.00
3-1/2
(89)
n/a
n/a
n/a
0.65
0.68
0.73
0.78
0.83
0.87
0.87
0.92
0.96
0.98
1.00
7-7/8
(200)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.62
0.65
0.66
0.70
0.75
0.79
0.82
0.84
0.88
0.92
0.95
0.99
1.00
10-1/2
(267)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.63
0.67
0.71
0.74
0.75
0.79
0.82
0.86
0.89
0.92
1.00
17-1/2
(445)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.63
0.66
0.69
0.72
0.75
0.77
0.85
0.98
3.2.5
3.2.6
3.2.7
3.2.8
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
5
(127)
6
(152)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
11-1/4 (286)
12
(305)
13
(330)
14
(356)
14-1/4 (362)
16
(406)
18
(457)
20
(508)
22
(559)
22-1/4 (565)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
4
(102)
n/a
0.59
0.61
0.61
0.63
0.65
0.66
0.68
0.70
0.71
0.72
0.74
0.76
0.76
0.79
0.83
0.86
0.90
0.91
0.94
0.97
1.00
9
(229)
n/a
0.59
0.61
0.61
0.63
0.65
0.66
0.68
0.70
0.71
0.72
0.74
0.76
0.76
0.79
0.83
0.86
0.90
0.91
0.94
0.97
1.00
12
(305)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.72
0.75
0.78
0.81
0.81
0.83
0.86
0.89
0.92
1.00
20
4
9
(508) (102) (229)
n/a 0.36 0.22
0.54 0.55 0.30
0.55 0.60 0.32
0.55 0.61 0.33
0.56 0.64 0.35
0.57 0.69 0.38
0.58 0.74 0.40
0.58 0.79 0.43
0.59 0.85 0.46
0.59 0.86 0.47
0.60 0.90 0.49
0.61 0.96 0.52
0.62 1.00 0.56
0.62
0.57
0.63
0.64
0.65
0.72
0.67
0.80
0.68
0.87
0.69
0.88
0.70
0.95
0.72
1.00
0.73
0.75
0.80
0.90
12
(305)
0.17
0.22
0.24
0.24
0.26
0.28
0.30
0.32
0.34
0.34
0.36
0.38
0.41
0.42
0.47
0.52
0.58
0.64
0.65
0.70
0.76
0.82
0.87
1.00
Spacing factor in
shear4
AV
20
4
9
(508) (102) (229)
0.10 n/a
n/a
0.13 0.59 0.54
0.14 0.60 0.55
0.14 0.61 0.55
0.15 0.62 0.55
0.16 0.64 0.56
0.17 0.65 0.57
0.19 0.67 0.58
0.20 0.69 0.58
0.20 0.69 0.59
0.21 0.70 0.59
0.22 0.72 0.60
0.24 0.74 0.61
0.24 0.74 0.61
0.27 0.77 0.62
0.31 0.81 0.64
0.34 0.84 0.65
0.38 0.88 0.67
0.38 0.88 0.67
0.41 0.91 0.68
0.44 0.94 0.70
0.48 0.98 0.71
0.51 1.00 0.73
0.62
0.77
0.82
0.86
12
(305)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.63
0.64
0.65
0.66
0.67
0.70
0.77
Toward edge
RV
20
4
9
(508) (102) (229)
n/a 0.08 0.02
0.52 0.37 0.11
0.52 0.48 0.14
0.52 0.51 0.15
0.52 0.61 0.18
0.53 0.74 0.22
0.53 0.89 0.26
0.53 1.00 0.31
0.54
0.35
0.54
0.37
0.54
0.40
0.54
0.46
0.55
0.51
0.55
0.52
0.55
0.62
0.56
0.74
0.57
0.87
0.58
1.00
0.58
0.58
0.59
0.60
0.60
0.62
0.66
12
(305)
0.01
0.07
0.09
0.10
0.12
0.14
0.17
0.20
0.23
0.24
0.26
0.30
0.33
0.34
0.40
0.48
0.56
0.65
0.66
0.74
0.84
0.94
1.00
To edge
RV
20
4
9
(508) (102) (229)
0.01 0.15 0.05
0.03 0.61 0.22
0.04 0.70 0.29
0.05 0.73 0.30
0.05 0.82 0.35
0.07 0.93 0.38
0.08 1.00 0.40
0.09
0.43
0.11
0.46
0.11
0.47
0.12
0.49
0.14
0.52
0.15
0.56
0.16
0.57
0.19
0.64
0.22
0.72
0.26
0.80
0.30
0.87
0.31
0.88
0.35
0.95
0.39
1.00
0.43
0.48
0.63
0.98
12
(305)
0.03
0.14
0.19
0.20
0.23
0.29
0.33
0.35
0.37
0.38
0.39
0.41
0.44
0.44
0.48
0.52
0.58
0.64
0.65
0.70
0.76
0.82
0.87
1.00
Concrete thickness
factor in shear5
HV
20
4
9
(508) (102) (229)
0.01 n/a
n/a
0.07 n/a
n/a
0.09 n/a
n/a
0.09 0.65 n/a
0.11 0.69 n/a
0.13 0.74 n/a
0.16 0.78 n/a
0.19 0.83 n/a
0.21 0.87 n/a
0.22 0.88 0.58
0.24 0.91 0.60
0.28 0.94 0.63
0.31 0.98 0.65
0.32 0.99 0.66
0.34 1.00 0.70
0.36
0.74
0.38
0.78
0.41
0.82
0.41
0.82
0.43
0.85
0.46
0.89
0.49
0.92
0.51
0.95
0.62
1.00
0.82
12
(305)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.64
0.67
0.71
0.71
0.74
0.77
0.80
0.83
0.91
1.00
20
(508)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.60
0.62
0.64
0.70
0.81
Table 53 - Load adjustment factors for 1-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
1-in.
cracked
concrete
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
5
(127)
6
(152)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
11-1/4 (286)
12
(305)
13
(330)
14
(356)
14-1/4 (362)
16
(406)
18
(457)
20
(508)
22
(559)
22-1/4 (565)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
4
(102)
n/a
0.59
0.61
0.61
0.63
0.65
0.66
0.68
0.70
0.71
0.72
0.74
0.76
0.76
0.79
0.83
0.86
0.90
0.91
0.94
0.97
1.00
9
(229)
n/a
0.59
0.61
0.61
0.63
0.65
0.66
0.68
0.70
0.71
0.72
0.74
0.76
0.76
0.79
0.83
0.86
0.90
0.91
0.94
0.97
1.00
12
(305)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.72
0.75
0.78
0.81
0.81
0.83
0.86
0.89
0.92
1.00
20
4
9
(508) (102) (229)
n/a 0.42 0.42
0.54 0.55 0.55
0.55 0.60 0.60
0.55 0.61 0.61
0.56 0.64 0.64
0.57 0.69 0.69
0.58 0.74 0.74
0.58 0.79 0.79
0.59 0.85 0.85
0.59 0.86 0.86
0.60 0.90 0.90
0.61 0.96 0.96
0.62 1.00 1.00
0.62
0.63
0.65
0.67
0.68
0.69
0.70
0.72
0.73
0.75
0.80
0.90
12
(305)
0.40
0.50
0.53
0.54
0.57
0.60
0.64
0.67
0.71
0.72
0.75
0.79
0.83
0.84
0.91
1.00
Spacing factor in
shear4
AV
20
4
9
(508) (102) (229)
0.38 n/a
n/a
0.44 0.59 0.54
0.46 0.60 0.55
0.46 0.61 0.55
0.47 0.62 0.55
0.49 0.64 0.56
0.51 0.65 0.57
0.53 0.67 0.58
0.55 0.69 0.58
0.56 0.69 0.59
0.57 0.71 0.59
0.59 0.72 0.60
0.62 0.74 0.61
0.62 0.74 0.61
0.66 0.77 0.62
0.70 0.81 0.64
0.75 0.84 0.65
0.80 0.88 0.67
0.80 0.88 0.67
0.85 0.91 0.68
0.90 0.95 0.70
0.95 0.98 0.71
1.00 1.00 0.73
0.77
0.87
12
(305)
n/a
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.58
0.59
0.61
0.62
0.63
0.63
0.64
0.65
0.66
0.68
0.71
0.78
Toward edge
RV
20
4
9
(508) (102) (229)
n/a 0.08 0.02
0.52 0.37 0.11
0.53 0.49 0.14
0.53 0.52 0.15
0.53 0.61 0.18
0.53 0.75 0.22
0.54 0.89 0.26
0.54 1.00 0.31
0.55
0.36
0.55
0.37
0.55
0.41
0.55
0.46
0.56
0.51
0.56
0.53
0.57
0.63
0.58
0.75
0.58
0.88
0.59
1.00
0.59
0.60
0.61
0.62
0.63
0.65
0.70
12
(305)
0.02
0.07
0.10
0.10
0.12
0.15
0.18
0.21
0.24
0.25
0.27
0.31
0.35
0.36
0.42
0.50
0.59
0.68
0.69
0.78
0.88
0.98
1.00
To edge
RV
20
4
9
(508) (102) (229)
0.01 0.15 0.05
0.04 0.74 0.22
0.06 0.97 0.29
0.06 1.00 0.31
0.07
0.36
0.09
0.44
0.11
0.53
0.13
0.62
0.14
0.72
0.15
0.74
0.16
0.82
0.19
0.92
0.21
1.00
0.21
0.25
0.30
0.35
0.41
0.42
0.47
0.53
0.59
0.65
0.86
1.00
12
(305)
0.03
0.15
0.19
0.21
0.24
0.30
0.36
0.42
0.48
0.50
0.55
0.62
0.69
0.71
0.85
1.00
Concrete thickness
factor in shear5
HV
20
4
9
(508) (102) (229)
0.02 n/a
n/a
0.09 n/a
n/a
0.12 n/a
n/a
0.12 0.66 n/a
0.15 0.69 n/a
0.18 0.74 n/a
0.21 0.79 n/a
0.25 0.83 n/a
0.29 0.87 n/a
0.30 0.88 0.59
0.33 0.91 0.61
0.37 0.95 0.63
0.42 0.98 0.65
0.43 0.99 0.66
0.51 1.00 0.70
0.61
0.74
0.71
0.78
0.80
0.82
0.80
0.82
0.85
0.86
0.90
0.89
0.95
0.92
1.00
0.96
1.00
12
(305)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.61
0.65
0.69
0.72
0.72
0.75
0.78
0.81
0.84
0.92
1.00
20
(508)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.63
0.66
0.68
0.71
0.78
0.90
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
13
(330)
14
(356)
14-1/4 (362)
15
(381)
16
(406)
17
(432)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
5
(127)
n/a
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.69
0.70
0.71
0.72
0.73
0.75
0.76
0.79
0.82
0.85
0.88
0.91
0.94
1.00
11-1/4
(286)
n/a
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.69
0.70
0.71
0.72
0.73
0.75
0.76
0.79
0.82
0.85
0.88
0.91
0.94
1.00
15
(381)
n/a
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.66
0.67
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
25
5 11-1/4
(635) (127) (286)
n/a 0.35 0.23
0.54 0.55 0.31
0.55 0.58 0.33
0.55 0.62 0.35
0.56 0.65 0.37
0.57 0.69 0.39
0.57 0.73 0.41
0.58 0.77 0.44
0.59 0.82 0.46
0.59 0.86 0.49
0.60 0.87 0.49
0.60 0.90 0.51
0.61 0.95 0.54
0.61 0.99 0.56
0.62 1.00 0.60
0.63
0.66
0.65
0.73
0.66
0.80
0.67
0.86
0.69
0.93
0.70
1.00
0.74
1.00
0.82
15
(381)
0.16
0.22
0.23
0.25
0.26
0.28
0.29
0.31
0.33
0.34
0.35
0.36
0.38
0.40
0.42
0.47
0.51
0.56
0.61
0.65
0.70
0.84
1.00
Spacing factor in
shear4
AV
25
5 11-1/4
(635) (127) (286)
0.09 n/a
n/a
0.13 0.59 0.54
0.14 0.60 0.54
0.14 0.61 0.55
0.15 0.62 0.55
0.16 0.64 0.56
0.17 0.65 0.57
0.18 0.66 0.57
0.19 0.68 0.58
0.20 0.69 0.59
0.20 0.69 0.59
0.21 0.70 0.59
0.22 0.72 0.60
0.23 0.73 0.60
0.25 0.75 0.61
0.27 0.77 0.62
0.30 0.80 0.63
0.33 0.83 0.65
0.36 0.86 0.66
0.38 0.88 0.67
0.41 0.91 0.68
0.49 0.99 0.72
0.66 1.00 0.79
15
(381)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.72
Toward edge
RV
25
5 11-1/4
(635) (127) (286)
n/a 0.05 0.02
0.52 0.37 0.11
0.52 0.43 0.13
0.52 0.53 0.16
0.52 0.63 0.19
0.53 0.74 0.22
0.53 0.86 0.25
0.53 0.98 0.29
0.54 1.00 0.33
0.54
0.36
0.54
0.37
0.54
0.40
0.54
0.45
0.55
0.49
0.55
0.53
0.55
0.62
0.56
0.72
0.57
0.82
0.57
0.92
0.58
1.00
0.58
0.60
0.63
15
(381)
0.01
0.07
0.08
0.10
0.12
0.14
0.16
0.19
0.21
0.24
0.24
0.26
0.29
0.32
0.35
0.40
0.47
0.53
0.60
0.67
0.74
0.98
1.00
To edge
RV
25
5 11-1/4
(635) (127) (286)
0.01 0.11 0.03
0.03 0.63 0.22
0.04 0.69 0.26
0.05 0.78 0.31
0.06 0.87 0.37
0.07 0.97 0.39
0.08 1.00 0.41
0.09
0.44
0.10
0.46
0.11
0.49
0.11
0.49
0.12
0.51
0.13
0.54
0.15
0.56
0.16
0.60
0.19
0.66
0.22
0.73
0.25
0.80
0.28
0.86
0.31
0.93
0.35
1.00
0.45
1.00
0.70
15
(381)
0.02
0.14
0.17
0.20
0.24
0.29
0.33
0.35
0.36
0.38
0.38
0.39
0.41
0.43
0.44
0.48
0.51
0.56
0.61
0.65
0.70
0.84
1.00
Concrete thickness
factor in shear5
HV
25
5 11-1/4
(635) (127) (286)
0.02 n/a
n/a
0.07 n/a
n/a
0.08 n/a
n/a
0.10 0.66 n/a
0.11 0.70 n/a
0.13 0.74 n/a
0.15 0.78 n/a
0.17 0.81 n/a
0.20 0.84 n/a
0.22 0.87 0.58
0.23 0.88 0.59
0.24 0.91 0.60
0.27 0.94 0.62
0.29 0.96 0.64
0.32 0.99 0.66
0.34 1.00 0.70
0.36
0.73
0.37
0.76
0.39
0.79
0.41
0.82
0.43
0.85
0.50
0.94
0.66
1.00
11-1/4
(286)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.63
0.66
0.69
0.71
0.74
0.81
0.94
25
(635)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.63
0.72
3.2.3
3.2.4
3.2.4
Table 55 - Load adjustment factors for 1-1/4-in. diameter threaded rods in cracked concrete1,2,3
3.2.4
Spacing (s) / Edge distance (ca) / Concrete thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
13
(330)
14
(356)
14-1/4 (362)
15
(381)
16
(406)
17
(432)
18
(457)
20
(508)
22
(559)
24
(610)
26
(660)
28
(711)
30
(762)
36
(914)
>48 (1219)
Spacing factor in
tension
AN
5
(127)
n/a
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.69
0.70
0.71
0.72
0.73
0.75
0.76
0.79
0.82
0.85
0.88
0.91
0.94
1.00
11-1/4
(286)
n/a
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.69
0.70
0.71
0.72
0.73
0.75
0.76
0.79
0.82
0.85
0.88
0.91
0.94
1.00
15
(381)
n/a
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.66
0.67
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
25
5 11-1/4
(635) (127) (286)
n/a 0.40 0.40
0.54 0.55 0.55
0.55 0.58 0.58
0.55 0.62 0.62
0.56 0.65 0.65
0.57 0.69 0.69
0.57 0.73 0.73
0.58 0.77 0.77
0.59 0.82 0.82
0.59 0.86 0.86
0.60 0.87 0.87
0.60 0.90 0.90
0.61 0.95 0.95
0.61 0.99 0.99
0.62 1.00 1.00
0.63
0.65
0.66
0.67
0.69
0.70
0.74
0.82
15
(381)
0.39
0.50
0.52
0.55
0.57
0.60
0.63
0.66
0.69
0.72
0.73
0.75
0.78
0.81
0.85
0.91
0.98
1.00
Spacing factor in
shear4
AV
25
5 11-1/4
(635) (127) (286)
0.37 n/a
n/a
0.44 0.59 0.54
0.45 0.60 0.54
0.46 0.61 0.55
0.48 0.62 0.55
0.49 0.64 0.56
0.51 0.65 0.57
0.53 0.66 0.57
0.54 0.68 0.58
0.56 0.69 0.59
0.56 0.70 0.59
0.57 0.71 0.59
0.59 0.72 0.60
0.61 0.73 0.60
0.62 0.75 0.61
0.66 0.77 0.62
0.69 0.80 0.63
0.73 0.83 0.65
0.77 0.86 0.66
0.81 0.88 0.67
0.85 0.91 0.68
0.97 0.99 0.72
1.00 1.00 0.79
15
(381)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.57
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.72
Toward edge
RV
25
5 11-1/4
(635) (127) (286)
n/a 0.05 0.02
0.52 0.37 0.11
0.52 0.44 0.13
0.52 0.54 0.16
0.53 0.64 0.19
0.53 0.75 0.22
0.53 0.86 0.26
0.54 0.98 0.29
0.54 1.00 0.33
0.54
0.37
0.54
0.38
0.55
0.41
0.55
0.45
0.55
0.49
0.56
0.54
0.56
0.63
0.57
0.72
0.57
0.82
0.58
0.93
0.59
1.00
0.59
0.61
0.65
15
(381)
0.01
0.07
0.08
0.10
0.12
0.14
0.17
0.19
0.21
0.24
0.25
0.26
0.29
0.32
0.35
0.41
0.47
0.54
0.60
0.68
0.75
0.98
1.00
To edge
RV
25
5 11-1/4
(635) (127) (286)
0.01 0.11 0.03
0.04 0.74 0.22
0.05 0.88 0.26
0.06 1.00 0.32
0.07
0.38
0.08
0.44
0.09
0.51
0.10
0.58
0.12
0.66
0.13
0.73
0.14
0.75
0.15
0.82
0.16
0.90
0.18
0.98
0.19
1.00
0.23
0.26
0.30
0.33
0.37
0.41
0.54
0.84
15
(381)
0.02
0.14
0.17
0.21
0.25
0.29
0.33
0.38
0.43
0.48
0.49
0.53
0.58
0.64
0.70
0.82
0.94
1.00
Concrete thickness
factor in shear5
HV
25
5 11-1/4
(635) (127) (286)
0.01 n/a
n/a
0.08 n/a
n/a
0.09 n/a
n/a
0.11 0.66 n/a
0.14 0.70 n/a
0.16 0.74 n/a
0.18 0.78 n/a
0.21 0.81 n/a
0.24 0.85 n/a
0.26 0.88 0.58
0.27 0.89 0.59
0.29 0.91 0.61
0.32 0.94 0.63
0.35 0.97 0.64
0.38 0.99 0.66
0.45 1.00 0.70
0.52
0.73
0.59
0.77
0.67
0.80
0.75
0.83
0.83
0.86
0.97
0.94
1.00
1.00
11-1/4
(286)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.61
0.63
0.66
0.69
0.72
0.74
0.81
0.94
25
(635)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.67
0.77
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 91
Uncracked
concrete
Dry
concrete
Cracked
concrete
Water saturated
concrete
Permissible
Drilling
Method
Permissible
concrete
conditions
Symbol
hef
minimum
maximum
hs
Tinst
hmin
Units
Thread size
3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC
in.
0.65
0.81
1.00
1.09
in.
11/16
7/8
1-1/8
1-1/4
in.
4-3/8
6-3/4
8-1/8
(mm)
(110)
(125)
(170)
(205)
in.
3/8
1/2
5/8
3/4
in.
15/16
1-3/16
1-1/2
1-7/8
ft-lb
15
30
60
100
(Nm)
(20)
(40)
(81)
(136)
in.
5.9
6.7
9.1
10.6
(mm)
(150)
(170)
(230)
(270)
92 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4-3/8
(111)
5
(127)
6-3/4
(171)
8-1/8
(206)
7,140
(31.8)
8,720
(38.8)
13,680
(60.9)
18,065
(80.4)
7,820
(34.8)
9,555
(42.5)
14,985
(66.7)
19,790
(88.0)
9,030
(40.2)
11,030
(49.1)
17,305
(77.0)
22,850
(101.6)
11,060
(49.2)
13,510
(60.1)
21,190
(94.3)
27,985
(124.5)
15,375
(68.4)
18,785
(83.6)
29,460
(131.0)
38,910
(173.1)
16,840
(74.9)
20,575
(91.5)
32,275
(143.6)
42,620
(189.6)
19,445
(86.5)
23,760
(105.7)
37,265
(165.8)
49,215
(218.9)
23,815
(105.9)
29,100
(129.4)
45,645
(203.0)
60,275
(268.1)
Table 58 - Hilti HIT-HY 200 adhesive design strength with concrete / bond failure for Hilti HIS-N and HIS-RN internally
threaded inserts in cracked concrete 1,2,3,4,5,6,7,8,9
Tension Nn or Nr
Thread
size
3/8-16 UNC
1/2-13 UNC
5/8-11 UNC
3/4-10 UNC
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4-3/8
(111)
5
(127)
6-3/4
(171)
8-1/8
(206)
5,055
(22.5)
6,175
(27.5)
9,690
(43.1)
12,795
(56.9)
5,540
(24.6)
6,765
(30.1)
10,615
(47.2)
14,015
(62.3)
6,145
(27.3)
7,815
(34.8)
12,255
(54.5)
16,185
(72.0)
6,510
(29.0)
9,335
(41.5)
13,210
(58.8)
17,385
(77.3)
10,890
(48.4)
13,305
(59.2)
20,870
(92.8)
27,560
(122.6)
11,930
(53.1)
14,575
(64.8)
22,860
(101.7)
30,190
(134.3)
13,235
(58.9)
16,830
(74.9)
26,395
(117.4)
34,860
(155.1)
14,025
(62.4)
20,110
(89.5)
28,450
(126.6)
37,450
(166.6)
1
2
3
4
3.2.3
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Table 59 - Steel design strength for steel bolt and cap screw for Hilti HIS-N
and HIS-RN internally threaded inserts 1,2
ACI 318 Appendix D Based Design
ASTM A193 Grade B8M
stainless steel
ASTM A193 B7
Thread
size
3/8-16 UNC
1/2-13 UNC
5/8-11 UNC
3/4-10 UNC
Tensile3
Nsa
lb (kN)
Shear 4
Vsa
lb (kN)
6,300
(28.0)
11,530
(51.3)
18,365
(81.7)
27,180
(120.9)
3,490
(15.5)
6,385
(28.4)
10,170
(45.2)
15,055
(67.0)
seis,V5
0.7
0.7
0.7
0.7
Tensile3
Nsa
lb (kN)
Shear 4
Vsa
lb (kN)
5,540
(24.6)
10,145
(45.1)
16,160
(71.9)
23,915
(106.4)
3,070
(13.7)
5,620
(25.0)
8,950
(39.8)
13,245
(58.9)
seis,V5
0.7
0.7
0.7
0.7
1 See section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
2 HIT-Z and HIT-Z-R rods are to be considered brittle steel elements.
3 Tensile = Ase,N futa as noted in ACI 318 Appendix D.
4 Shear values determined by static shear tests with Vsa 0.60 Ase,V futa as noted in ACI 318 Appendix D.
5 Reduction factor for seismic shear only. See section 3.1.7.4 for additional information on seismic applications.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 93
Spacing (s) / Edge distanc (ca) / Concrete thickness (h), - in. (mm)
Embedment
hef
Spacing factor in
shear 4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear 5
HV
3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4
4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8
(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)
in.
in.
3-1/4
(83)
0.59
n/a
n/a
n/a
0.35
n/a
n/a
n/a
0.55
n/a
n/a
n/a
0.15
n/a
n/a
n/a
0.31
n/a
n/a
n/a
n/a
n/a
n/a
n/a
(102)
0.61 0.59
n/a
n/a
0.39 0.38
n/a
n/a
0.56 0.55
n/a
n/a
0.21 0.19
n/a
n/a
0.39 0.38
n/a
n/a
n/a
n/a
n/a
n/a
(127)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5-1/2
(140)
0.65 0.62 0.60 0.59 0.48 0.46 0.39 0.35 0.58 0.58 0.56 0.55 0.34 0.30 0.19 0.15 0.48 0.46 0.39 0.29
n/a
n/a
n/a
n/a
(152)
0.67 0.64 0.61 0.60 0.51 0.48 0.41 0.37 0.59 0.58 0.56 0.55 0.39 0.35 0.22 0.17 0.51 0.48 0.41 0.33 0.60
n/a
n/a
n/a
(178)
0.70 0.66 0.63 0.62 0.59 0.54 0.45 0.40 0.60 0.60 0.57 0.56 0.49 0.43 0.28 0.21 0.59 0.54 0.45 0.40 0.64 0.62
n/a
n/a
(203)
0.72 0.68 0.65 0.63 0.67 0.61 0.49 0.43 0.62 0.61 0.58 0.57 0.60 0.53 0.34 0.26 0.67 0.61 0.49 0.43 0.69 0.66
n/a
n/a
(229)
0.75 0.70 0.66 0.65 0.76 0.69 0.54 0.46 0.63 0.62 0.59 0.58 0.71 0.63 0.40 0.31 0.76 0.69 0.54 0.46 0.73 0.70
n/a
n/a
10
(254)
0.78 0.73 0.68 0.67 0.84 0.76 0.58 0.50 0.65 0.64 0.60 0.58 0.83 0.74 0.47 0.36 0.84 0.76 0.58 0.50 0.77 0.74 0.64
n/a
11
(279)
0.81 0.75 0.70 0.68 0.93 0.84 0.64 0.53 0.66 0.65 0.61 0.59 0.96 0.86 0.55 0.41 0.93 0.84 0.64 0.53 0.81 0.78 0.67 0.61
12
(305)
0.84 0.77 0.72 0.70 1.00 0.91 0.70 0.57 0.68 0.66 0.62 0.60 1.00 0.98 0.62 0.47 1.00 0.91 0.70 0.57 0.84 0.81 0.70 0.64
14
(356)
16
(406)
0.96 0.73
18
(457)
1.00 0.87
24
(610)
1.00
30
(762)
1.00 1.00
36
(914)
>48
(1219)
1.00
Table 61 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete1,2,3
Edge distance in shear
HIS-N and HIS-RN
all diameters
cracked concrete
Thread Size
Spacing (s) / Edge distanc (ca) / Concrete thickness (h), - in. (mm)
Embedment
hef
Spacing factor in
tension
AN
Spacing factor in
shear 4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear 5
HV
3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4 3/8 1/2 5/8 3/4
4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8 4-3/8 5 6-3/4 8-1/8
(mm) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206) (111) (127) (171) (206)
in.
in.
3-1/4
(83)
0.59
n/a
n/a
n/a
0.55
n/a
n/a
n/a
0.55
n/a
n/a
n/a
0.16
n/a
n/a
n/a
0.31
n/a
n/a
n/a
n/a
n/a
n/a
n/a
(102)
0.61 0.59
n/a
n/a
0.60 0.55
n/a
n/a
0.56 0.55
n/a
n/a
0.21 0.19
n/a
n/a
0.42 0.38
n/a
n/a
n/a
n/a
n/a
n/a
(127)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5-1/2
(140)
0.65 0.62 0.60 0.59 0.72 0.63 0.57 0.55 0.58 0.58 0.56 0.55 0.34 0.31 0.19 0.15 0.69 0.61 0.39 0.29
n/a
n/a
n/a
n/a
(152)
0.67 0.64 0.61 0.60 0.75 0.66 0.60 0.57 0.59 0.58 0.56 0.55 0.39 0.35 0.22 0.17 0.78 0.70 0.44 0.34 0.60
n/a
n/a
n/a
(178)
0.70 0.66 0.63 0.62 0.84 0.72 0.64 0.62 0.60 0.60 0.57 0.56 0.49 0.44 0.28 0.21 0.98 0.88 0.56 0.42 0.64 0.62
n/a
n/a
(203)
0.72 0.68 0.65 0.63 0.92 0.79 0.69 0.66 0.62 0.61 0.58 0.57 0.60 0.54 0.34 0.26 1.00 1.00 0.68 0.52 0.69 0.66
n/a
n/a
(229)
0.75 0.70 0.66 0.65 1.00 0.85 0.74 0.71 0.63 0.62 0.59 0.58 0.72 0.64 0.41 0.31 1.00 1.00 0.82 0.62 0.73 0.70
n/a
n/a
10
(254)
0.92 0.79 0.75 0.65 0.64 0.60 0.58 0.84 0.75 0.48 0.36
n/a
11
(279)
0.99 0.85 0.80 0.66 0.65 0.61 0.59 0.97 0.86 0.55 0.42
12
(305)
1.00 0.90 0.85 0.68 0.66 0.62 0.60 1.00 0.98 0.63 0.48
14
(356)
16
(406)
0.97 0.73
18
(457)
1.00 0.87
1.00
24
(610)
30
(762)
1.00 1.00
36
(914)
>48
(1219)
1.00 1.00
94 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Behavior
+
5%
+
10%
10%
+
10%
+
+
10%
3.2.3
+
+
+
+
96%
10%
10%
10%
10%
10%
+
+
+
+
+
+
+
10%
2%
10%
30%
+
+
+
+
+
+
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
non-resistant
+ resistant
limited resistance
7/16
2-3/8
Qty
40
7/16
2-3/8
40
7/16
2-3/8
40
9/16
2-3/4
20
HIT-Z 1/2 x 6
9/16
2-3/4
20
HIT-Z 1/2 x 8
9/16
2-3/4
20
HIT-Z 5/8 x 6
3/4
3-3/4
12
HIT-Z 5/8 x 8
3/4
3-3/4
12
12
3/4
3-3/4
7/8
HIT-Z 3/4 x 9
7/8
HIT-HY 200-A
HIT-HY 200-R
Description
Package contents
Includes (1) foil pack with (1) mixer and 3/8 filler tube per pack
Qty
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8 filler tube per pack
25
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8 filler tube per pack and
(1) HDM 500 Manual Dispenser
25
Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8 filler tube per pack
20
Includes (2) master cartons containing (20) foil packs each with (1) mixer and 3/8 filler tube per
pack and (1) HDM 500 Manual Dispenser
40
Package contents
Includes (1) foil pack with (1) mixer and 3/8 filler tube per pack
Qty
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8 filler tube per pack
25
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8 filler tube per pack and
(1) HDM 500 manual dispenser
25
Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8 filler tube per pack
20
Includes (2) master cartons containing (20) foil packs each with (1) mixer and 3/8 filler tube per
pack and (1) HDM 500 manual dispenser
40
9-1/2
9-1/2
9-1/2
15-1/2
15-1/2
15-1/2
15-1/2
96 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Description
Qty
Qty
Description
3/8 x 4-3/8
10
240
3/8x 5-1/8
20
200
3/8 x 5-1/8
3/8 x 8
10
160
3/8 x 12
10
90
1/2 x 3-1/8
10
240
1/2 x 4-1/2
10
160
1/2 x 6-1/2
20
160
1/2 x 6-1/2
Qty
Description
3/8 x 5-1/8
20
3/8 x 5-1/8
3/8 x 8
10
3/8 x 8
20
20
1/2 x 6-1/2
20
1/2 x 6-1/2
Qty
20
10
20
1/2x 8
10
120
1/2 x 8
10
1/2 x 8
10
1/2 x 10
10
120
1/2 x 10
10
1/2 x 11
10
1/2 x 12
10
1/2 x 12
10
80
5/8 x 8
20
80
5/8 x 7-5/8
5/8 x 9
10
60
20
-
5/8 x 7-5/8
20
5/8 x 7-5/8
20
5/8 x 10
10
5/8 x 9
10
10
5/8 x 12
10
60
5/8 x 12
5/8 x 17
10
40
3/4 x 10
10
40
3/4 x 9-5/8
10
3/4 x 9-5/8
10
3/4 x 9-5/8
10
3/4 x 10
10
3/4 x 11
10
30
3/4 x 12
10
30
3/4 x 12
10
3/4 x 14
10
30
3/4 x 14
10
3/4 x 14
10
3/4 x 16
3/4 x 17
10
20
3/4 x 16
10
3/4 x 19
10
20
3/4 x 21
10
20
3/4 x 25
10
20
7/8 x 10
10
20
7/8 x 10 HDG
7/8 x 10
7/8 x 12 HDG
7/8 x 13
1 x 12
10
-
7/8 x 10
-
10
20
7/8 x 16 HDG
7/8 x 16
16
1 x 12
1 x 12
1 x 12
3.2.3
3.2.4
10
10
3.2.4
3.2.4
10
4
1 x 14
16
1 x 14
1 x 16
12
1 x 16
1 x 16
1 x 20
12
1 x 21
1 x 20
1-1/4 x 16
1-1/4 x 16
1-1/4 x 22
1-1/4 x 23
3.2.5
3.2.6
3.2.7
3.2.8
HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1
Description
Qty
10
1-3/16
5/8 x 6-5/8
1-1/2
3/4 x 8-1/4
3/8 x 4-1/4
1/2 x 5
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 97
Manual
Description
Red
Black
98 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Diameter in.
Length ft
Qty
Blow-Out Pump
For use in holes up to 10 in. deep
0.39
2.6
0.71
2.6
0.39
0.63
0.63
3.3
2.3
10
0.63
1
1
10
0.63
33
HIT-DRS
Dust Removal System with one hole for vacuum
attachment and another hole for the Blow-Out Tool. For
use with compressed air
3.2.3
Air nozzles
Description
HIT-DL 1/2
Use with 10 mm diameter hose
HIT-DL 9/16
Use with 10 mm diameter hose
HIT-DL 11/16
Use with 10 mm diameter hose
HIT-DL 3/4
Use with 16 mm diameter hose/tube
HIT-DL 7/8
Use with 16 mm diameter hose/tube
HIT-DL 1
Use with 16 mm diameter hose/tube
HIT-DL 1-3/8
Use with 16 mm diameter hose/tube
3.2.4
3.2.4
3.2.4
3.2.5
Also
avaliable in
metric!
1 HIT-DL size determined by the diameter of drilled hole; see Accessory Selection Table below for proper sizing
3.2.6
3.2.7
3.2.8
Round brush2
Description
Air nozzle
Hole diameter1
Description
7/16
HIT-RB 7/16
1/2
HIT-RB 1/2
HIT-IP 1/2
9 mm
Description
HIT-DL 1/2
9/16
HIT-RB 9/16
HIT-IP 9/16
9 mm
HIT-DL 9/16
5/8
HIT-RB 5/8
HIT-IP 5/8
9 mm
11/16
HIT-RB 11/16
HIT-IP 11/16
3/4
HIT-RB 3/4
HIT-IP 3/4
16 mm
HIT-DL 3/4
7/8
HIT-RB 7/8
HIT-IP 7/8
16 mm
HIT-DL 7/8
HIT-RB 1
HIT-IP 1
16 mm
HIT-DL 1
1-1/8
HIT-RB 1 1/8
HIT-IP 1 1/8
16 mm
1-1/4
HIT-RB 1 1/4
HIT-IP 1 1/4
16 mm
1- 3/8
HIT-RB 1 3/8
HIT-IP 1 3/8
16 mm
HIT-DL 1 3/8
1-1/2
HIT-RB 1 1/2
HIT-IP 1 1/2
16 mm
1-3/4
HIT-RB 1 3/4
HIT-IP 1 3/4
16 mm
9 mm
HIT-DL 11/16
1 Refer to adhesive anchor system installation instructions to determine the proper hole diameter for the fastening element to be used.
2 Attach brush to HIT-RBH T-handle, HIT-RBS or HIT-RBV extensions.
3 Use piston plugs to help prevent air voids during injection.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 99
Description
HIT-RBH (T-handle)
Use to clean holes up to 11 in. deep
Qty
Description
Qty
Connects RBS extension to your Hilti drill for use in cleaning holes
Description
Qty
Diameter in
Length ft
HIT-RBS 10/0.7
0.39
2.3
Qty
HIT-RBS-10/0.35
0.39
1.2
Diameter in.
Length ft
Qty
0.35
3.3
10
0.63
2.3
10
0.63
33
HIT-VL K
Plastic coupler for connecting 16 mm (0.63 in.) hoses
and tubes
Diameter in.
Qty
0.63
Qty
7/16 to 1-1/4
100
7/16 to 5/8
10
11/16 to 1-1/4
10
100 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 101
Product Description
3.2.4.2
Material Specifications
3.2.4.3
Technical Data
3.2.4.4
Installation Instructions
3.2.4.5
Ordering Information
Listings/Approvals
ICC-ES (International Code Council)
ESR-2322
NSF/ANSI Std 61
certification for use in potable water
European Technical Approval
ETA-07/0260, ETA-09/0295
COLA (City of Los Angeles)
RR25700
Product features
Superior bond performance
Seismic qualified per IBC/IRC
2009, IBC/IRC 2006, IBC/IRC
2003 and IBC/IRC 2000. Please
refer to ESR-2322 for Seismic
Design Category A through F
Use in diamond cored or
pneumatic drilled holes
Use underwater up to 165 ft (50 m)
Meets requirements of ASTM
C881-90, Type IV, Grade 2 and 3,
Class A, B, C except gel times
Meets requirements of AASHTO
specification M235, Type IV, Grade
3, Class A, B, C except gel times
Mixing tube provides proper
mixing, eliminates measuring errors
and minimizes waste
Contains no styrene and virtually
odorless
Extended temperature range from
41F to 104F (5C to 40C)
Excellent weathering resistance
and resistant to elevated
temperature.
102 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.2.3
3.2.5
3.2.4
3.2.5
12.4 MPa
12.4 MPa
1800 psi
1800 psi
82.7 MPa
12,000 psi
1493 MPa
43.5 MPa
6310 psi
2.0%
2.0%
63C
146F
0.06%
0.06%
0.004
0.004
6.6 x 1013 /m
3.2.5
3.2.6
3.2.7
3.2.8
Material Specifications for HAS threaded rods are listed in Section 3.2.4.2.
Material Specifications for HIS-N Internally Threaded Inserts are listed in Section 3.2.4.3.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 103
Effective
embedment
Symbol
Units
do
hef,std
minimum
hef,min
maximum
hef,max
hmin
Rebar size
3
10
in.
1/2
5/8
3/4
7/8
1-1/8
1-3/8
1-1/2
in.
3-3/8
4-1/2
5-5/8
6-3/4
7-7/8
(mm)
(86)
(114)
(143)
(171)
(200)
(229)
(257)
in.
2-3/8
2-3/4
3-1/8
3-1/2
3-1/2
4-1/2
(mm)
(60)
(70)
(79)
(89)
(89)
(102)
(114)
(127)
in.
7-1/2
10
12-1/2
15
17-1/2
20
22-1/2
25
(mm)
(191)
(254)
(318)
(381)
(445)
(508)
(572)
(635)
in.
hef + 1-1/4
(mm)
hef + 30
10-1/8 11-1/4
(286)
hef + 2do
104 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Rebar size
1
2
3
4
5
6
7
8
9
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
Shear Vn or Vr
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
3-3/8
4,835
5,300
5,855
6,205
10,415
11,410
12,610
13,365
(86)
(21.5)
(23.6)
(26.0)
(27.6)
(46.3)
(50.8)
(56.1)
(59.5)
4-1/2
7,445
7,805
7,805
8,275
16,035
16,810
16,810
17,820
#3
(114)
(33.1)
(34.7)
(34.7)
(36.8)
(71.3)
(74.8)
(74.8)
(79.3)
7-1/2
13,010
13,010
13,010
13,790
28,020
28,020
28,020
29,700
(191)
(57.9)
(57.9)
(57.9)
(61.3)
(124.6)
(124.6)
(124.6)
(132.1)
4-1/2
7,445
8,155
9,420
10,885
16,035
17,570
20,285
23,445
(114)
(33.1)
(36.3)
(41.9)
(48.4)
(71.3)
(78.2)
(90.2)
(104.3)
6
11,465
12,560
13,690
14,515
24,690
27,045
29,490
31,260
#4
(152)
(51.0)
(55.9)
(60.9)
(64.6)
(109.8)
(120.3)
(131.2)
(139.1)
10
22,820
22,820
22,820
24,190
49,150
49,150
49,150
52,100
(254)
(101.5)
(101.5)
(101.5)
(107.6)
(218.6)
(218.6)
(218.6)
(231.8)
5-5/8
10,405
11,400
13,165
16,120
22,415
24,550
28,350
34,720
(143)
(46.3)
(50.7)
(58.6)
(71.7)
(99.7)
(109.2)
(126.1)
(154.4)
7-1/2
16,020
17,550
20,265
21,765
34,505
37,800
43,650
46,875
#5
(191)
(71.3)
(78.1)
(90.1)
(96.8)
(153.5)
(168.1)
(194.2)
(208.5)
12-1/2
34,220
34,220
34,220
36,275
73,705
73,705
73,705
78,125
(318)
(152.2)
(152.2)
(152.2)
(161.4)
(327.9)
(327.9)
(327.9)
(347.5)
6-3/4
13,680
14,985
17,305
21,190
29,460
32,275
37,265
45,645
(171)
(60.9)
(66.7)
(77.0)
(94.3)
(131.0)
(143.6)
(165.8)
(203.0)
9
21,060
23,070
26,640
30,170
45,360
49,690
57,375
64,985
#6
(229)
(93.7)
(102.6)
(118.5)
(134.2)
(201.8)
(221.0)
(255.2)
(289.1)
15
45,315
47,440
47,440
50,285
97,600
102,175
102,175
108,305
(381)
(201.6)
(211.0)
(211.0)
(223.7)
(434.1)
(454.5)
(454.5)
(481.8)
7-7/8
17,235
18,885
21,805
25,240
37,125
40,670
46,960
57,515
(200)
(76.7)
(84.0)
(97.0)
(112.3)
(165.1)
(180.9)
(208.9)
(255.8)
10-1/2
26,540
29,070
31,750
33,655
57,160
62,615
72,300
85,665
#7
(267)
(118.1)
(129.3)
(141.2)
(149.7)
(254.3)
(278.5)
(321.6)
(381.1)
17-1/2
52,915
52,915
52,915
56,090
122,990
134,695
134,695
142,780
(445)
(235.4)
(235.4)
(235.4)
(249.5)
(547.1)
(599.2)
(599.2)
(635.1)
9
21,060
23,070
26,640
32,060
45,360
49,690
57,375
70,270
(229)
(93.7)
(102.6)
(118.5)
(142.6)
(201.8)
(221.0)
(255.2)
(312.6)
12
32,425
35,520
40,330
42,750
69,835
76,500
88,335
108,190
#8
(305)
(144.2)
(158.0)
(179.4)
(190.2)
(310.6)
(340.3)
(392.9)
(481.3)
20
67,215
67,215
67,215
71,245
150,265
164,605
171,090
181,355
(508)
(299.0)
(299.0)
(299.0)
(316.9)
(668.4)
(732.2)
(761.0)
(806.7)
10-1/8
25,130
27,530
31,785
38,930
54,125
59,290
68,465
83,850
(257)
(111.8)
(122.5)
(141.4)
(173.2)
(240.8)
(263.7)
(304.5)
(373.0)
13-1/2
38,690
42,380
48,940
52,850
83,330
91,285
105,405
129,095
#9
(343)
(172.1)
(188.5)
(217.7)
(235.1)
(370.7)
(406.1)
(468.9)
(574.2)
22-1/2
83,100
83,100
83,100
88,085
179,300
196,415
211,525
224,220
(572)
(369.6)
(369.6)
(369.6)
(391.8)
(797.6)
(873.7)
(940.9)
(997.4)
11-1/4
29,430
32,240
37,230
45,595
63,395
69,445
80,185
98,205
(286)
(130.9)
(143.4)
(165.6)
(202.8)
(282.0)
(308.9)
(356.7)
(436.8)
15
45,315
49,640
57,320
63,875
97,600
106,915
123,455
151,200
#10
(381)
(201.6)
(220.8)
(255.0)
(284.1)
(434.1)
(475.6)
(549.2)
(672.6)
25
97,500
100,435
100,435
106,460
210,000
230,045
255,645
270,985
(635)
(433.7)
(446.8)
(446.8)
(473.6)
(934.1)
(1023.3)
(1137.2)
(1205.4)
See Section 3.1.7 for explanation on development of load values.
See Section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Apply spacing, edge distance, and concrete thickness factors in Tables 6-21 as necessary. Compare to the steel values in Table 5.
The lesser of the values is to be used for the design.
Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C).
For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by 0.34.
Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly
constant over significant periods of time.
Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by 0.69.
For water-filled drilled holes multiply design strength (factored resistance) by 0.63.
For submerged (under water) applications multiply design strength (factored resistance) by 0.64.
Tabular values are for short term loads only. For sustained loads including overhead use, see Section 3.1.7.5.
Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by a as follows:
For sand-lightweight, a = 0.51. For all-lightweight, a = 0.45.
Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. For diamond core drilling multiply above value by 0.51.
Diamond core drilling is not permitted for the water-filled or underwater (submerged) applications.
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 105
Rebar size
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
Shear Vn or Vr
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
3-3/8
2,815
2,815
2,815
2,985
6,065
6,065
6,065
6,430
(86)
(12.5)
(12.5)
(12.5)
(13.3)
(27.0)
(27.0)
(27.0)
(28.6)
4-1/2
3,755
3,755
3,755
3,980
8,090
8,090
8,090
8,575
#3
(114)
(16.7)
(16.7)
(16.7)
(17.7)
(36.0)
(36.0)
(36.0)
(38.1)
7-1/2
6,260
6,260
6,260
6,635
13,485
13,485
13,485
14,290
(191)
(27.8)
(27.8)
(27.8)
(29.5)
(60.0)
(60.0)
(60.0)
(63.6)
4-1/2
4,940
4,940
4,940
5,235
10,640
10,640
10,640
11,275
(114)
(22.0)
(22.0)
(22.0)
(23.3)
(47.3)
(47.3)
(47.3)
(50.2)
6
6,585
6,585
6,585
6,980
14,185
14,185
14,185
15,035
#4
(152)
(29.3)
(29.3)
(29.3)
(31.0)
(63.1)
(63.1)
(63.1)
(66.9)
10
10,975
10,975
10,975
11,635
23,640
23,640
23,640
25,060
(254)
(48.8)
(48.8)
(48.8)
(51.8)
(105.2)
(105.2)
(105.2)
(111.5)
5-5/8
7,370
7,500
7,500
7,950
15,875
16,160
16,160
17,130
(143)
(32.8)
(33.4)
(33.4)
(35.4)
(70.6)
(71.9)
(71.9)
(76.2)
7-1/2
10,005
10,005
10,005
10,605
21,545
21,545
21,545
22,835
#5
(191)
(44.5)
(44.5)
(44.5)
(47.2)
(95.8)
(95.8)
(95.8)
(101.6)
12-1/2
16,670
16,670
16,670
17,670
35,905
35,905
35,905
38,060
(318)
(74.2)
(74.2)
(74.2)
(78.6)
(159.7)
(159.7)
(159.7)
(169.3)
6-3/4
9,690
10,340
10,340
10,960
20,870
22,265
22,265
23,600
(171)
(43.1)
(46.0)
(46.0)
(48.8)
(92.8)
(99.0)
(99.0)
(105.0)
9
13,785
13,785
13,785
14,610
29,690
29,690
29,690
31,470
#6
(229)
(61.3)
(61.3)
(61.3)
(65.0)
(132.1)
(132.1)
(132.1)
(140.0)
15
22,975
22,975
22,975
24,350
49,480
49,480
49,480
52,450
(381)
(102.2)
(102.2)
(102.2)
(108.3)
(220.1)
(220.1)
(220.1)
(233.3)
7-7/8
10,895
10,895
10,895
11,550
26,300
27,730
27,730
29,395
(200)
(48.5)
(48.5)
(48.5)
(51.4)
(117.0)
(123.3)
(123.3)
(130.8)
10-1/2
14,525
14,525
14,525
15,395
36,975
36,975
36,975
39,190
#7
(267)
(64.6)
(64.6)
(64.6)
(68.5)
(164.5)
(164.5)
(164.5)
(174.3)
17-1/2
24,210
24,210
24,210
25,660
61,625
61,625
61,625
65,320
(445)
(107.7)
(107.7)
(107.7)
(114.1)
(274.1)
(274.1)
(274.1)
(290.6)
9
13,295
13,295
13,295
14,095
32,130
33,845
33,845
35,875
(229)
(59.1)
(59.1)
(59.1)
(62.7)
(142.9)
(150.5)
(150.5)
(159.6)
12
17,730
17,730
17,730
18,790
45,125
45,125
45,125
47,835
#8
(305)
(78.9)
(78.9)
(78.9)
(83.6)
(200.7)
(200.7)
(200.7)
(212.8)
20
29,545
29,545
29,545
31,320
75,210
75,210
75,210
79,720
(508)
(131.4)
(131.4)
(131.4)
(139.3)
(334.5)
(334.5)
(334.5)
(354.6)
10-1/8
15,745
15,745
15,745
16,690
38,340
40,080
40,080
42,485
(257)
(70.0)
(70.0)
(70.0)
(74.2)
(170.5)
(178.3)
(178.3)
(189.0)
13-1/2
20,995
20,995
20,995
22,255
53,440
53,440
53,440
56,645
#9
(343)
(93.4)
(93.4)
(93.4)
(99.0)
(237.7)
(237.7)
(237.7)
(252.0)
22-1/2
34,990
34,990
34,990
37,090
89,065
89,065
89,065
94,410
(572)
(155.6)
(155.6)
(155.6)
(165.0)
(396.2)
(396.2)
(396.2)
(420.0)
11-1/4
17,740
17,740
17,740
18,800
44,905
45,150
45,150
47,860
(286)
(78.9)
(78.9)
(78.9)
(83.6)
(199.7)
(200.8)
(200.8)
(212.9)
15
23,650
23,650
23,650
25,070
60,200
60,200
60,200
63,815
#10
(381)
(105.2)
(105.2)
(105.2)
(111.5)
(267.8)
(267.8)
(267.8)
(283.9)
25
39,415
39,415
39,415
41,780
100,335
100,335
100,335
106,355
(635)
(175.3)
(175.3)
(175.3)
(185.8)
(446.3)
(446.3)
(446.3)
(473.1)
1 See Section 3.1.7 for explanation on development of load values.
2 See Section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
3 Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
4 Apply spacing, edge distance, and concrete thickness factors in Tables 6-21 as necessary. Compare to the steel values in Table 5.
The lesser of the values is to be used for the design.
5 Data is for temperature range A: Max. short term temperature = 110 F (43 C), max. long term temperature = 80 F (26 C).
For temperature range B: Max. short term temperature = 162 F (72 C), max. long term temperature = 110 F (43 C) multiply above value by 0.34.
Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly
constant over significant periods of time.
6 Tabular values are for dry concrete conditions. For water saturated concrete multiply design strength (factored resistance) by 0.69.
For water-filled drilled holes multiply design strength (factored resistance) by 0.63.
For submerged (under water) applications multiply design strength (factored resistance) by 0.64.
7 Tabular values are for short term loads only. For sustained loads including overhead use, see Section 3.1.7.5.
8 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength (factored resistance) by a as follows:
For sand-lightweight, a = 0.51. For all-lightweight, a = 0.45.
9 Tabular values are for static loads only. For seismic loads, multiply above value by seis = 0.49. See section 3.1.7.4 for additional information on seismic applications.
10 Tabular values are for holes drilled in concrete with carbide tipped hammer drill bit. Diamond core drilling is not permitted in cracked concrete conditions.
106 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Shear
Vsa
lb (kN)
Seismic Shear
Vsa
lb (kN)
4,290
(19.1)
7,800
(34.7)
12,090
(53.8)
17,160
(76.3)
23,400
(104.1)
30,810
(137.0)
39,000
(173.5)
49,530
(220.3)
2,375
(10.6)
4,320
(19.2)
6,695
(29.8)
9,505
(42.3)
12,960
(57.6)
17,065
(75.9)
21,600
(96.1)
27,430
(122.0)
1,663
(7.4)
3,024
(13.5)
4,687
(20.8)
6,654
(29.6)
9,072
(40.4)
11,946
(53.1)
15,120
(67.3)
19,201
(85.4)
Rebar size
#3
#4
#5
#6
#7
#8
#9
#10
1
2
3
4
5
Tensile
Nsa
lb (kN)
Shear
Vsa
lb (kN)
Seismic Shear
Vsa
lb (kN)
6,435
(28.6)
11,700
(52.0)
18,135
(80.7)
25,740
(114.5)
35,100
(156.1)
46,215
(205.6)
58,500
(260.2)
74,295
(330.5)
3,565
(15.9)
6,480
(28.8)
10,045
(44.7)
14,255
(63.4)
19,440
(86.5)
25,595
(113.9)
32,400
(144.1)
41,150
(183.0)
2,496
(11.1)
4,536
(20.2)
7,032
(31.3)
9,979
(44.4)
13,608
(60.5)
17,917
(79.7)
22,680
(100.9)
28,805
(128.1)
Tensile
Nsa
lb (kN)
Shear4
Vsa
lb (kN)
Seismic Shear5
Vsa
lb (kN)
6,600
(29.4)
12,000
(53.4)
18,600
(82.7)
26,400
(117.4)
36,000
(160.1)
47,400
(210.8)
60,000
(266.9)
76,200
(339.0)
3,430
(15.3)
6,240
(27.8)
9,670
(43.0)
13,730
(61.1)
18,720
(83.3)
24,650
(109.6)
31,200
(138.8)
39,625
(176.3)
2,401
(10.7)
4,368
(19.4)
6,769
(30.1)
9,611
(42.8)
13,104
(58.3)
17,255
(76.8)
21,840
(97.1)
27,738
(123.4)
See Section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
ASTM A706 Grade 60 rebar are considered ductile steel elements. ASTM A615 Grade 40 and 60 rebar are considered brittle steel elements.
Tensile = Ase,N futa as noted in ACI 318 Appendix D.
Shear = 0.60 Ase,N futa as noted in ACI 318 Appendix D
Seismic shear values determined by multiplying Vsa x V,seis where V,seis = 0.7. See Section 3.1.7.4 for additional information on seismic applications.
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 107
Spacing factor
in shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
(mm)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
1-3/4 (44)
1-7/8 (48)
2
(51)
3
(76)
3-5/8 (92)
4
(102)
4-5/8 (117)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
8
(203)
8-3/4 (222)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
24
(610)
30
(762)
36
(914)
>48 (1219)
n/a
0.58
0.59
0.63
0.66
0.68
0.70
0.72
0.75
0.77
0.81
0.85
0.89
0.90
0.94
0.99
1.00
n/a
0.57
0.57
0.61
0.63
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.82
0.83
0.87
0.91
0.94
1.00
n/a
0.54
0.54
0.57
0.58
0.59
0.60
0.61
0.63
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.81
0.86
0.90
1.00
0.28
0.29
0.29
0.36
0.41
0.43
0.48
0.51
0.59
0.61
0.71
0.82
0.89
0.92
1.00
0.22
0.22
0.23
0.28
0.31
0.33
0.36
0.38
0.43
0.45
0.52
0.59
0.65
0.67
0.74
0.82
0.89
1.00
0.13
0.13
0.13
0.16
0.18
0.19
0.21
0.22
0.25
0.26
0.30
0.34
0.38
0.39
0.43
0.47
0.52
0.60
0.69
0.77
1.00
n/a
0.53
0.53
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.68
0.70
0.73
0.76
0.79
0.89
0.99
1.00
n/a
0.52
0.52
0.54
0.54
0.55
0.56
0.56
0.57
0.57
0.59
0.60
0.61
0.61
0.62
0.63
0.65
0.67
0.70
0.72
0.79
0.87
0.94
1.00
n/a
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.65
0.70
0.75
0.80
0.90
0.07
0.08
0.09
0.16
0.21
0.24
0.30
0.34
0.42
0.45
0.57
0.69
0.79
0.83
0.97
1.00
0.05
0.05
0.06
0.10
0.14
0.16
0.20
0.22
0.27
0.29
0.37
0.45
0.51
0.54
0.63
0.72
0.83
1.00
0.03
0.03
0.03
0.06
0.08
0.09
0.11
0.13
0.16
0.17
0.21
0.26
0.29
0.31
0.36
0.41
0.47
0.60
0.73
0.87
1.00
0.14
0.16
0.17
0.32
0.41
0.43
0.48
0.51
0.59
0.61
0.71
0.82
0.89
0.92
1.00
0.09
0.10
0.11
0.21
0.27
0.32
0.38
0.40
0.44
0.46
0.52
0.59
0.65
0.67
0.74
0.82
0.89
1.00
0.05
0.06
0.06
0.12
0.16
0.18
0.23
0.25
0.31
0.32
0.35
0.38
0.40
0.41
0.44
0.48
0.52
0.60
0.69
0.77
1.00
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.61
0.63
0.68
0.72
0.76
0.77
0.81
0.85
0.88
0.96
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.53
0.54
0.58
0.63
0.65
0.66
0.70
0.73
0.77
0.83
0.88
0.94
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.55
0.58
0.61
0.64
0.69
0.73
0.78
0.90
1.00
Embedment
hef
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Spacing factor
in tension
AN
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
(mm)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
1-3/4 (44)
n/a
n/a
n/a
0.52
0.49
0.43
n/a
n/a
n/a
0.09
0.07
0.04
0.17
0.13
0.08
n/a
n/a
n/a
1-7/8 (48)
0.58
0.57
0.54
0.53
0.50
0.44
0.53
0.53
0.52
0.10
0.07
0.04
0.19
0.14
0.09
n/a
n/a
n/a
2
(51)
0.59
0.57
0.54
0.55
0.51
0.44
0.54
0.53
0.52
0.11
0.08
0.05
0.21
0.16
0.10
n/a
n/a
n/a
3
(76)
0.63
0.61
0.57
0.66
0.60
0.49
0.56
0.55
0.53
0.19
0.15
0.09
0.39
0.29
0.18
n/a
n/a
n/a
3-5/8 (92)
0.66
0.63
0.58
0.73
0.66
0.53
0.57
0.56
0.54
0.26
0.19
0.12
0.52
0.39
0.23
n/a
n/a
n/a
4
(102) 0.68
0.65
0.59
0.78
0.70
0.55
0.57
0.56
0.54
0.30
0.22
0.13
0.60
0.45
0.27
n/a
n/a
n/a
4-5/8 (117) 0.70
0.67
0.60
0.86
0.76
0.58
0.59
0.57
0.55
0.37
0.28
0.17
0.75
0.56
0.34
0.59
n/a
n/a
5
(127) 0.72
0.69
0.61
0.91
0.80
0.60
0.59
0.58
0.55
0.42
0.31
0.19
0.84
0.63
0.38
0.61
n/a
n/a
5-3/4 (146) 0.75
0.71
0.63
1.00
0.88
0.64
0.61
0.59
0.56
0.52
0.39
0.23
1.00
0.78
0.47
0.66
0.60
n/a
6
(152) 0.77
0.72
0.63
0.91
0.66
0.61
0.59
0.57
0.55
0.41
0.25
0.83
0.50
0.67
0.61
n/a
7
(178) 0.81
0.76
0.66
1.00
0.72
0.63
0.61
0.58
0.69
0.52
0.31
1.00
0.62
0.72
0.66
n/a
8
(203) 0.85
0.80
0.68
0.78
0.65
0.62
0.59
0.85
0.64
0.38
0.76
0.77
0.70
n/a
8-3/4 (222) 0.89
0.82
0.69
0.83
0.66
0.63
0.60
0.97
0.73
0.44
0.83
0.81
0.73
0.62
9
(229) 0.90
0.83
0.70
0.85
0.67
0.64
0.60
1.00
0.76
0.46
0.85
0.82
0.74
0.63
10
(254) 0.94
0.87
0.72
0.91
0.69
0.65
0.61
0.89
0.53
0.91
0.86
0.79
0.66
11
(279) 0.99
0.91
0.74
0.98
0.71
0.67
0.62
1.00
0.62
0.98
0.91
0.82
0.69
12
(305) 1.00
0.94
0.77
1.00
0.72
0.68
0.63
0.70
1.00
0.95
0.86
0.73
14
(356)
1.00
0.81
0.76
0.72
0.65
0.88
1.00
0.93
0.78
16
(406)
0.86
0.80
0.75
0.68
1.00
0.99
0.84
18
(457)
0.90
0.84
0.78
0.70
1.00
0.89
24
(610)
1.00
0.95
0.87
0.76
1.00
30
(762)
1.00
0.96
0.83
36
(914)
1.00
0.89
>48 (1219)
1.00
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
1
2
3
4
5
108 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
(mm)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
1-3/4
(44)
2-1/2
(64)
3
(76)
4
(102)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
7-1/4 (184)
8
(203)
9
(229)
10
(254)
11-1/4 (286)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
22
(559)
24
(610)
30
(762)
36
(914)
> 48 (1219)
n/a
0.58
0.60
0.63
0.67
0.69
0.70
0.73
0.74
0.77
0.80
0.83
0.88
0.90
0.97
1.00
n/a
0.57
0.58
0.61
0.64
0.66
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
n/a
0.54
0.55
0.57
0.58
0.60
0.60
0.62
0.62
0.63
0.65
0.67
0.69
0.70
0.73
0.77
0.80
0.83
0.87
0.90
1.00
0.25
0.28
0.30
0.35
0.40
0.45
0.46
0.52
0.54
0.60
0.67
0.75
0.84
0.90
1.00
0.19
0.22
0.24
0.27
0.31
0.34
0.35
0.39
0.40
0.44
0.49
0.55
0.62
0.66
0.77
0.88
0.99
1.00
0.11
0.13
0.14
0.16
0.18
0.20
0.20
0.23
0.23
0.26
0.29
0.32
0.36
0.38
0.45
0.51
0.58
0.64
0.70
0.77
0.96
1.00
n/a
0.53
0.54
0.55
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.72
0.74
0.77
0.80
0.82
0.90
0.98
1.00
n/a
0.53
0.53
0.54
0.55
0.56
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.68
0.70
0.72
0.74
0.80
0.86
0.98
n/a
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.69
0.73
0.81
0.05
0.09
0.12
0.18
0.26
0.32
0.34
0.42
0.45
0.52
0.62
0.72
0.86
0.95
1.00
0.03
0.06
0.08
0.12
0.17
0.21
0.22
0.28
0.29
0.34
0.40
0.47
0.56
0.62
0.78
0.95
1.00
0.02
0.03
0.04
0.06
0.08
0.10
0.11
0.14
0.15
0.17
0.20
0.24
0.28
0.31
0.39
0.48
0.57
0.67
0.77
0.88
1.00
0.11
0.18
0.24
0.35
0.40
0.45
0.46
0.52
0.54
0.60
0.67
0.75
0.84
0.90
1.00
0.07
0.12
0.15
0.24
0.33
0.36
0.37
0.41
0.42
0.45
0.49
0.55
0.62
0.66
0.77
0.88
0.99
1.00
0.03
0.06
0.08
0.12
0.17
0.21
0.22
0.28
0.29
0.32
0.34
0.36
0.39
0.41
0.46
0.51
0.58
0.64
0.70
0.77
0.96
1.00
n/a
n/a
n/a
n/a
n/a
0.56
0.57
0.61
0.62
0.66
0.70
0.73
0.78
0.80
0.87
0.93
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.57
0.60
0.64
0.67
0.70
0.75
0.80
0.85
0.90
0.94
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.55
0.60
0.64
0.68
0.71
0.75
0.78
0.87
0.96
1.00
Embedment
hef
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Spacing factor
in tension
AN
Embedment
hef
4
5
Spacing factor
in shear4
AV
To edge
RV
Toward edge
RV
Concrete thickness
factor in shear5
HV
in.
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
3-3/8
4-1/2
7-1/2
(mm)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
(86)
(114)
(191)
1-3/4
(44)
n/a
n/a
n/a
0.48
0.45
0.41
n/a
n/a
n/a
0.06
0.04
0.03
0.11
0.09
0.05
n/a
n/a
n/a
2-1/2
(64)
0.58
0.57
0.54
0.53
0.50
0.44
0.54
0.53
0.52
0.10
0.07
0.04
0.20
0.15
0.09
n/a
n/a
n/a
3
(76)
0.60
0.58
0.55
0.57
0.53
0.46
0.54
0.53
0.52
0.13
0.10
0.06
0.26
0.19
0.12
n/a
n/a
n/a
4
(102)
0.63
0.61
0.57
0.66
0.60
0.49
0.56
0.55
0.53
0.20
0.15
0.09
0.39
0.30
0.18
n/a
n/a
n/a
5
(127)
0.67
0.64
0.58
0.75
0.67
0.53
0.57
0.56
0.54
0.28
0.21
0.12
0.55
0.41
0.25
n/a
n/a
n/a
5-3/4 (146)
0.69
0.66
0.60
0.82
0.73
0.56
0.58
0.57
0.55
0.34
0.26
0.15
0.68
0.51
0.31
0.57
n/a
n/a
6
(152)
0.70
0.67
0.60
0.85
0.75
0.57
0.58
0.57
0.55
0.36
0.27
0.16
0.73
0.54
0.33
0.58
n/a
n/a
7
(178)
0.73
0.69
0.62
0.95
0.83
0.62
0.60
0.58
0.56
0.46
0.34
0.21
0.91
0.69
0.41
0.63
n/a
n/a
7-1/4 (184)
0.74
0.70
0.62
0.98
0.85
0.63
0.60
0.58
0.56
0.48
0.36
0.22
0.96
0.72
0.43
0.64
0.58
n/a
8
(203)
0.77
0.72
0.63
1.00
0.91
0.66
0.61
0.59
0.57
0.56
0.42
0.25
1.00
0.84
0.50
0.67
0.61
n/a
9
(229)
0.80
0.75
0.65
1.00
0.70
0.63
0.60
0.57
0.67
0.50
0.30
1.00
0.60
0.71
0.65
n/a
10
(254)
0.83
0.78
0.67
0.75
0.64
0.62
0.58
0.78
0.59
0.35
0.70
0.75
0.68
n/a
11-1/4 (286)
0.88
0.81
0.69
0.81
0.66
0.63
0.59
0.93
0.70
0.42
0.81
0.80
0.72
0.61
12
(305)
0.90
0.83
0.70
0.85
0.67
0.64
0.60
1.00
0.77
0.46
0.85
0.82
0.75
0.63
14
(356)
0.97
0.89
0.73
0.95
0.70
0.66
0.62
0.97
0.58
0.95
0.89
0.81
0.68
16
(406)
1.00
0.94
0.77
1.00
0.73
0.69
0.63
1.00
0.71
1.00
0.95
0.86
0.73
18
(457)
1.00
0.80
0.75
0.71
0.65
0.85
1.00
0.92
0.77
20
(508)
0.83
0.78
0.73
0.67
0.99
0.97
0.81
22
(559)
0.87
0.81
0.76
0.68
1.00
1.00
0.85
24
(610)
0.90
0.84
0.78
0.70
0.89
30
(762)
1.00
0.92
0.85
0.75
1.00
36
(914)
1.00
0.92
0.80
> 48 (1219)
1.00
0.90
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
1
2
3
Spacing factor
in tension
AN
3.2.5
3.2.4
3.2.5
3.2.3
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 109
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1-3/4
3-1/8
4
4-5/8
5
6
7
7-1/8
8
9
10
11
12
14
16
18
20
22
24
26
28
30
36
> 48
Spacing factor
in tension
AN
in.
5-5/8
(mm) (143)
(44)
n/a
(79)
0.59
(102) 0.61
(117) 0.63
(127) 0.64
(152) 0.66
(178) 0.69
(181) 0.69
(203) 0.72
(229) 0.75
(254) 0.77
(279) 0.80
(305) 0.83
(356) 0.88
(406) 0.94
(457) 0.99
(508) 1.00
(559)
(610)
(660)
(711)
(762)
(914)
(1219)
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
7-1/2 12-1/2
(191) (318)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
n/a
0.59
n/a
0.62
n/a
0.65
n/a
0.70
0.54
0.75
0.58
0.79
0.61
0.83
0.65
0.87
0.68
0.91
0.71
0.95
0.74
0.99
0.77
1.00
0.79
0.87
1.00
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
in.
5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2 5-5/8 7-1/2 12-1/2
(mm) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318) (143) (191) (318)
1-3/4 (44)
n/a
n/a
n/a
0.45
0.43
0.40
n/a
n/a
n/a
0.04
0.03
0.02
0.09
0.06
0.04
n/a
n/a
n/a
3-1/8 (79)
0.59
0.57
0.54
0.54
0.50
0.44
0.54
0.53
0.52
0.10
0.08
0.05
0.20
0.15
0.09
n/a
n/a
n/a
4
(102) 0.61
0.59
0.55
0.60
0.55
0.46
0.55
0.54
0.53
0.15
0.11
0.07
0.30
0.22
0.13
n/a
n/a
n/a
4-5/8 (117) 0.63
0.60
0.56
0.64
0.58
0.48
0.55
0.54
0.53
0.18
0.14
0.08
0.37
0.27
0.16
n/a
n/a
n/a
5
(127) 0.64
0.61
0.57
0.67
0.60
0.49
0.56
0.55
0.53
0.21
0.15
0.09
0.41
0.30
0.18
n/a
n/a
n/a
6
(152) 0.66
0.63
0.58
0.74
0.66
0.53
0.57
0.56
0.54
0.27
0.20
0.12
0.54
0.40
0.24
n/a
n/a
n/a
7
(178) 0.69
0.66
0.59
0.82
0.72
0.56
0.58
0.57
0.55
0.34
0.25
0.15
0.68
0.50
0.30
n/a
n/a
n/a
7-1/8 (181) 0.69
0.66
0.60
0.83
0.73
0.56
0.58
0.57
0.55
0.35
0.26
0.16
0.70
0.52
0.31
0.58
n/a
n/a
8
(203) 0.72
0.68
0.61
0.90
0.78
0.59
0.59
0.58
0.55
0.42
0.31
0.19
0.84
0.62
0.37
0.61
n/a
n/a
9
(229) 0.75
0.70
0.62
0.99
0.85
0.62
0.60
0.59
0.56
0.50
0.37
0.22
1.00
0.74
0.44
0.65
0.59
n/a
10
(254) 0.77
0.72
0.63
1.00
0.91
0.66
0.62
0.60
0.57
0.58
0.43
0.26
0.86
0.52
0.68
0.62
n/a
11
(279) 0.80
0.74
0.65
0.98
0.69
0.63
0.60
0.57
0.67
0.50
0.30
0.98
0.60
0.72
0.65
n/a
12
(305) 0.83
0.77
0.66
1.00
0.73
0.64
0.61
0.58
0.77
0.57
0.34
1.00
0.68
0.75
0.68
n/a
14
(356) 0.88
0.81
0.69
0.81
0.66
0.63
0.59
0.97
0.71
0.43
0.81
0.81
0.73
0.62
16
(406) 0.94
0.86
0.71
0.89
0.69
0.65
0.61
1.00
0.87
0.52
0.89
0.86
0.78
0.66
18
(457) 0.99
0.90
0.74
0.97
0.71
0.67
0.62
1.00
0.62
0.97
0.92
0.83
0.70
20
(508) 1.00
0.94
0.77
1.00
0.73
0.69
0.64
0.73
1.00
0.97
0.87
0.74
22
(559)
0.99
0.79
0.76
0.71
0.65
0.84
1.00
0.91
0.77
24
(610)
1.00
0.82
0.78
0.73
0.66
0.96
0.96
0.81
26
(660)
0.85
0.80
0.75
0.68
1.00
0.99
0.84
28
(711)
0.87
0.83
0.77
0.69
1.00
0.87
30
(762)
0.90
0.85
0.79
0.70
0.90
36
(914)
0.98
0.92
0.84
0.74
0.99
> 48 (1219)
1.00
1.00
0.96
0.82
1.00
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1
2
3
4
5
110 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1-3/4
3-3/4
4
5
5-1/4
6
7
8
8-1/2
9
10
10-3/4
12
14
16
16-3/4
18
20
22
24
26
28
30
36
> 48
Spacing factor
in tension
AN
in.
6-3/4
(mm) (171)
(44)
n/a
(95)
0.59
(102) 0.59
(127) 0.62
(133) 0.62
(152) 0.64
(178) 0.66
(203) 0.69
(216) 0.70
(229) 0.71
(254) 0.73
(273) 0.75
(305) 0.78
(356) 0.82
(406) 0.87
(425) 0.89
(457) 0.92
(508) 0.96
(559) 1.00
(610)
(660)
(711)
(762)
(914)
(1219)
9
(229)
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.69
0.70
0.72
0.76
0.80
0.81
0.83
0.87
0.91
0.94
0.98
1.00
15
(381)
n/a
0.54
0.54
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
9
(229)
0.18
0.22
0.22
0.25
0.25
0.27
0.30
0.32
0.34
0.35
0.38
0.40
0.45
0.53
0.60
0.63
0.68
0.75
0.83
0.90
0.98
1.00
15
(381)
0.10
0.13
0.13
0.15
0.15
0.16
0.17
0.19
0.20
0.21
0.22
0.24
0.26
0.31
0.35
0.37
0.40
0.44
0.48
0.53
0.57
0.62
0.66
0.79
1.00
Spacing factor
in shear4
AV
6-3/4
(171)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.70
0.72
0.74
0.76
0.78
0.80
0.86
0.99
9
(229)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.61
0.62
0.63
0.64
0.65
0.67
0.68
0.70
0.71
0.73
0.77
0.86
15
(381)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.72
To edge
RV
Toward edge
RV
6-3/4
(171)
0.03
0.11
0.12
0.17
0.18
0.22
0.28
0.34
0.37
0.40
0.47
0.53
0.62
0.78
0.96
1.00
9
(229)
0.02
0.07
0.08
0.11
0.12
0.14
0.18
0.22
0.24
0.26
0.31
0.34
0.40
0.51
0.62
0.67
0.74
0.87
1.00
15
(381)
0.01
0.03
0.04
0.05
0.05
0.07
0.08
0.10
0.11
0.12
0.14
0.16
0.19
0.24
0.29
0.31
0.35
0.40
0.47
0.53
0.60
0.67
0.74
0.98
1.00
6-3/4
(171)
0.07
0.22
0.24
0.33
0.34
0.36
0.40
0.43
0.45
0.47
0.51
0.55
0.61
0.71
0.82
0.85
0.92
1.00
9
(229)
0.05
0.14
0.16
0.22
0.23
0.29
0.33
0.35
0.37
0.38
0.41
0.43
0.46
0.53
0.60
0.63
0.68
0.75
0.83
0.90
0.98
1.00
Concrete thickness
factor in shear5
HV
15
(381)
0.02
0.07
0.07
0.10
0.11
0.13
0.17
0.20
0.22
0.24
0.29
0.31
0.33
0.36
0.39
0.40
0.42
0.45
0.49
0.53
0.57
0.62
0.66
0.79
1.00
6-3/4
(171)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.60
0.64
0.66
0.70
0.75
0.80
0.82
0.85
0.90
0.94
0.99
1.00
9
(229)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.65
0.70
0.71
0.74
0.78
0.82
0.85
0.89
0.92
0.95
1.00
15
(381)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.60
0.63
0.66
0.69
0.71
0.74
0.81
0.94
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
4
5
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
in.
6-3/4
9
15
6-3/4
9
15
6-3/4
9
15
6-3/4
9
15
6-3/4
9
15
6-3/4
9
15
(mm) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381) (171) (229) (381)
1-3/4 (44)
n/a
n/a
n/a
0.44
0.42
0.39
n/a
n/a
n/a
0.03
0.02
0.01
0.07
0.05
0.03
n/a
n/a
n/a
3-3/4 (95)
0.59
0.57
0.54
0.54
0.50
0.44
0.54
0.53
0.52
0.11
0.08
0.05
0.22
0.15
0.09
n/a
n/a
n/a
4
(102) 0.59
0.57
0.54
0.56
0.51
0.44
0.54
0.53
0.52
0.12
0.08
0.05
0.24
0.17
0.10
n/a
n/a
n/a
5
(127) 0.62
0.59
0.56
0.61
0.56
0.47
0.55
0.54
0.53
0.17
0.12
0.07
0.34
0.24
0.14
n/a
n/a
n/a
5-1/4 (133) 0.62
0.60
0.56
0.63
0.57
0.47
0.55
0.54
0.53
0.18
0.13
0.08
0.36
0.26
0.15
n/a
n/a
n/a
6
(152) 0.64
0.61
0.57
0.67
0.60
0.49
0.56
0.55
0.53
0.22
0.16
0.09
0.44
0.31
0.19
n/a
n/a
n/a
7
(178) 0.66
0.63
0.58
0.74
0.65
0.52
0.57
0.56
0.54
0.28
0.20
0.12
0.56
0.39
0.24
n/a
n/a
n/a
8
(203) 0.69
0.65
0.59
0.80
0.70
0.55
0.58
0.56
0.55
0.34
0.24
0.14
0.68
0.48
0.29
n/a
n/a
n/a
8-1/2 (216) 0.70
0.66
0.59
0.84
0.72
0.56
0.59
0.57
0.55
0.37
0.26
0.16
0.75
0.53
0.32
0.59
n/a
n/a
9
(229) 0.71
0.67
0.60
0.87
0.75
0.57
0.59
0.57
0.55
0.41
0.29
0.17
0.82
0.57
0.34
0.61
n/a
n/a
10
(254) 0.73
0.69
0.61
0.94
0.80
0.60
0.60
0.58
0.56
0.48
0.34
0.20
0.95
0.67
0.40
0.64
n/a
n/a
10-3/4 (273) 0.75
0.70
0.62
1.00
0.84
0.62
0.61
0.59
0.56
0.53
0.37
0.22
1.00
0.75
0.45
0.66
0.59
n/a
12
(305) 0.78
0.72
0.63
0.91
0.66
0.62
0.60
0.57
0.63
0.44
0.26
0.88
0.53
0.70
0.62
n/a
14
(356) 0.82
0.76
0.66
1.00
0.72
0.64
0.61
0.58
0.79
0.56
0.33
1.00
0.67
0.76
0.67
n/a
16
(406) 0.87
0.80
0.68
0.78
0.66
0.63
0.59
0.97
0.68
0.41
0.78
0.81
0.72
n/a
16-3/4 (425) 0.89
0.81
0.69
0.81
0.67
0.63
0.60
1.00
0.73
0.44
0.81
0.83
0.73
0.62
18
(457) 0.92
0.83
0.70
0.85
0.68
0.64
0.60
0.81
0.49
0.85
0.86
0.76
0.64
20
(508) 0.96
0.87
0.72
0.91
0.70
0.66
0.61
0.95
0.57
0.91
0.90
0.80
0.68
22
(559) 1.00
0.91
0.74
0.98
0.72
0.68
0.63
1.00
0.66
0.98
0.95
0.84
0.71
24
(610)
0.94
0.77
1.00
0.74
0.69
0.64
0.75
1.00
0.99
0.88
0.74
26
(660)
0.98
0.79
0.76
0.71
0.65
0.84
1.00
0.91
0.77
28
(711)
1.00
0.81
0.79
0.73
0.66
0.94
0.95
0.80
30
(762)
0.83
0.81
0.74
0.67
1.00
0.98
0.83
36
(914)
0.90
0.87
0.79
0.71
1.00
0.91
> 48 (1219)
1.00
0.99
0.89
0.77
1.00
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Embedment
hef
1
2
3
Spacing factor
in tension
AN
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 111
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1-3/4
4-3/8
5
5-1/2
6
7
8
9
9-7/8
10
11
12
12-1/2
14
16
18
19-1/2
20
22
24
26
28
30
36
> 48
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
in.
7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2
(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)
(44)
n/a
n/a
n/a
0.22
0.17
0.10
n/a
n/a
n/a
0.03
0.02
0.01
0.05
0.04
0.02
n/a
n/a
n/a
(111) 0.59
0.57
0.54
0.29
0.22
0.13
0.54
0.53
0.52
0.11
0.07
0.03
0.22
0.14
0.07
n/a
n/a
n/a
(127) 0.60
0.58
0.55
0.31
0.23
0.14
0.54
0.53
0.52
0.13
0.09
0.04
0.27
0.17
0.08
n/a
n/a
n/a
(140) 0.61
0.59
0.55
0.32
0.24
0.14
0.55
0.54
0.52
0.15
0.10
0.05
0.31
0.20
0.09
n/a
n/a
n/a
(152) 0.62
0.60
0.56
0.34
0.25
0.15
0.55
0.54
0.52
0.17
0.11
0.05
0.34
0.23
0.11
n/a
n/a
n/a
(178) 0.64
0.61
0.57
0.37
0.27
0.16
0.56
0.55
0.53
0.22
0.14
0.07
0.37
0.29
0.13
n/a
n/a
n/a
(203) 0.66
0.63
0.58
0.40
0.30
0.17
0.57
0.55
0.53
0.27
0.17
0.08
0.40
0.33
0.16
n/a
n/a
n/a
(229) 0.68
0.64
0.59
0.43
0.32
0.19
0.58
0.56
0.54
0.32
0.21
0.10
0.43
0.35
0.19
n/a
n/a
n/a
(251) 0.70
0.66
0.59
0.46
0.34
0.20
0.59
0.56
0.54
0.37
0.24
0.11
0.46
0.37
0.22
0.59
n/a
n/a
(254) 0.70
0.66
0.60
0.46
0.34
0.20
0.59
0.57
0.54
0.38
0.24
0.11
0.46
0.37
0.23
0.59
n/a
n/a
(279) 0.72
0.67
0.60
0.49
0.37
0.22
0.60
0.57
0.54
0.43
0.28
0.13
0.49
0.40
0.26
0.62
n/a
n/a
(305) 0.74
0.69
0.61
0.53
0.39
0.23
0.60
0.58
0.55
0.49
0.32
0.15
0.53
0.42
0.30
0.65
n/a
n/a
(318) 0.75
0.70
0.62
0.55
0.41
0.24
0.61
0.58
0.55
0.52
0.34
0.16
0.55
0.43
0.31
0.66
0.57
n/a
(356) 0.78
0.72
0.63
0.62
0.46
0.27
0.62
0.59
0.55
0.62
0.40
0.19
0.62
0.47
0.33
0.70
0.60
n/a
(406) 0.82
0.75
0.65
0.71
0.52
0.31
0.64
0.60
0.56
0.76
0.49
0.23
0.71
0.52
0.36
0.75
0.65
n/a
(457) 0.86
0.79
0.67
0.80
0.59
0.34
0.66
0.62
0.57
0.91
0.59
0.27
0.80
0.59
0.38
0.79
0.68
n/a
(495) 0.89
0.81
0.69
0.86
0.63
0.37
0.67
0.63
0.58
1.00
0.66
0.31
0.86
0.63
0.40
0.82
0.71
0.55
(508) 0.90
0.82
0.69
0.89
0.65
0.38
0.67
0.63
0.58
0.69
0.32
0.89
0.65
0.41
0.83
0.72
0.56
(559) 0.94
0.85
0.71
0.97
0.72
0.42
0.69
0.64
0.59
0.80
0.37
0.97
0.72
0.44
0.87
0.76
0.59
(610) 0.98
0.88
0.73
1.00
0.78
0.46
0.71
0.66
0.59
0.91
0.42
1.00
0.78
0.47
0.91
0.79
0.61
(660) 1.00
0.91
0.75
0.85
0.50
0.73
0.67
0.60
1.00
0.48
0.85
0.50
0.95
0.82
0.64
(711)
0.94
0.77
0.91
0.53
0.74
0.68
0.61
0.53
0.91
0.53
0.99
0.85
0.66
(762)
0.98
0.79
0.98
0.57
0.76
0.70
0.62
0.59
0.98
0.57
1.00
0.88
0.68
(914)
1.00
0.84
1.00
0.69
0.81
0.73
0.64
0.77
1.00
0.69
0.97
0.75
(1219)
0.96
0.92
0.92
0.81
0.69
1.00
0.92
1.00
0.87
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
in.
7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2 7-7/8 10-1/2 17-1/2
(mm) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445) (200) (267) (445)
1-3/4 (44)
n/a
n/a
n/a
0.42
0.41
0.38
n/a
n/a
n/a
0.03
0.02
0.01
0.06
0.04
0.02
n/a
n/a
n/a
4-3/8 (111) 0.59
0.57
0.54
0.55
0.50
0.44
0.54
0.53
0.52
0.11
0.08
0.05
0.22
0.16
0.09
n/a
n/a
n/a
5
(127) 0.60
0.58
0.55
0.58
0.52
0.45
0.54
0.53
0.52
0.13
0.10
0.06
0.27
0.19
0.11
n/a
n/a
n/a
5-1/2 (140) 0.61
0.59
0.55
0.60
0.54
0.46
0.55
0.54
0.53
0.15
0.11
0.07
0.31
0.22
0.13
n/a
n/a
n/a
6
(152) 0.62
0.60
0.56
0.63
0.56
0.47
0.55
0.54
0.53
0.18
0.13
0.08
0.35
0.25
0.15
n/a
n/a
n/a
7
(178) 0.64
0.61
0.57
0.68
0.60
0.49
0.56
0.55
0.53
0.22
0.16
0.09
0.44
0.32
0.19
n/a
n/a
n/a
8
(203) 0.66
0.63
0.58
0.74
0.64
0.52
0.57
0.56
0.54
0.27
0.19
0.12
0.54
0.39
0.23
n/a
n/a
n/a
9
(229) 0.68
0.64
0.59
0.79
0.68
0.54
0.58
0.56
0.54
0.32
0.23
0.14
0.65
0.46
0.28
n/a
n/a
n/a
9-7/8 (251) 0.70
0.66
0.59
0.84
0.72
0.56
0.59
0.57
0.55
0.37
0.26
0.16
0.74
0.53
0.32
0.59
n/a
n/a
10
(254) 0.70
0.66
0.60
0.85
0.73
0.56
0.59
0.57
0.55
0.38
0.27
0.16
0.76
0.54
0.32
0.59
n/a
n/a
11
(279) 0.72
0.67
0.60
0.91
0.77
0.59
0.60
0.58
0.55
0.44
0.31
0.19
0.87
0.62
0.37
0.62
n/a
n/a
12
(305) 0.74
0.69
0.61
0.98
0.82
0.61
0.60
0.58
0.56
0.50
0.35
0.21
1.00
0.71
0.42
0.65
n/a
n/a
12-1/2 (318) 0.75
0.70
0.62
1.00
0.84
0.62
0.61
0.59
0.56
0.53
0.38
0.23
0.75
0.45
0.66
0.59
n/a
14
(356) 0.78
0.72
0.63
0.91
0.66
0.62
0.60
0.57
0.63
0.45
0.27
0.89
0.54
0.70
0.62
n/a
16
(406) 0.82
0.75
0.65
1.00
0.71
0.64
0.61
0.58
0.77
0.55
0.33
1.00
0.65
0.75
0.67
n/a
18
(457) 0.86
0.79
0.67
0.76
0.66
0.63
0.59
0.91
0.65
0.39
0.76
0.79
0.71
n/a
19-1/2 (495) 0.89
0.81
0.69
0.80
0.67
0.64
0.60
1.00
0.73
0.44
0.80
0.82
0.74
0.62
20
(508) 0.90
0.82
0.69
0.82
0.67
0.64
0.60
0.76
0.46
0.82
0.84
0.75
0.63
22
(559) 0.94
0.85
0.71
0.87
0.69
0.65
0.61
0.88
0.53
0.87
0.88
0.78
0.66
24
(610) 0.98
0.88
0.73
0.93
0.71
0.67
0.62
1.00
0.60
0.93
0.92
0.82
0.69
26
(660) 1.00
0.91
0.75
0.99
0.73
0.68
0.63
0.68
0.99
0.95
0.85
0.72
28
(711)
0.94
0.77
1.00
0.74
0.69
0.64
0.76
1.00
0.99
0.88
0.74
30
(762)
0.98
0.79
0.76
0.71
0.65
0.84
1.00
0.91
0.77
36
(914)
1.00
0.84
0.81
0.75
0.68
1.00
1.00
0.84
> 48 (1219)
0.96
0.92
0.83
0.74
0.97
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1
2
3
4
5
112 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1-3/4
5
6
6-1/4
7
8
9
10
11
11-1/4
12
13
14
14-1/4
16
18
20
22
22-1/4
24
26
28
30
36
> 48
in.
(mm)
(44)
(127)
(152)
(159)
(178)
(203)
(229)
(254)
(279)
(286)
(305)
(330)
(356)
(362)
(406)
(457)
(508)
(559)
(565)
(610)
(660)
(711)
(762)
(914)
(1219)
Spacing factor
in tension
AN
9
(229)
n/a
0.59
0.61
0.61
0.63
0.64
0.66
0.68
0.70
0.70
0.72
0.73
0.75
0.76
0.79
0.82
0.86
0.89
0.90
0.93
0.97
1.00
12
(305)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.72
0.75
0.78
0.81
0.81
0.83
0.86
0.89
0.92
1.00
20
(508)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.62
0.63
0.65
0.67
0.68
0.69
0.70
0.72
0.73
0.75
0.80
0.90
12
(305)
0.17
0.22
0.24
0.24
0.26
0.28
0.29
0.32
0.34
0.34
0.36
0.38
0.40
0.41
0.46
0.52
0.58
0.63
0.64
0.69
0.75
0.81
0.86
1.00
20
(508)
0.10
0.13
0.14
0.14
0.15
0.16
0.17
0.18
0.20
0.20
0.21
0.22
0.24
0.24
0.27
0.30
0.34
0.37
0.38
0.40
0.44
0.47
0.51
0.61
0.81
Spacing factor
in shear4
AV
9
(229)
n/a
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.61
0.62
0.64
0.65
0.67
0.67
0.68
0.70
0.71
0.73
0.77
0.86
12
(305)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.63
0.64
0.65
0.66
0.67
0.70
0.77
20
(508)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.58
0.59
0.60
0.60
0.62
0.66
To edge
RV
Toward edge
RV
9
(229)
0.02
0.11
0.14
0.15
0.18
0.22
0.26
0.31
0.35
0.37
0.40
0.46
0.51
0.52
0.62
0.74
0.87
1.00
12
(305)
0.01
0.07
0.09
0.10
0.12
0.14
0.17
0.20
0.23
0.24
0.26
0.30
0.33
0.34
0.40
0.48
0.56
0.65
0.66
0.74
0.84
0.94
1.00
20
(508)
0.01
0.03
0.04
0.05
0.05
0.07
0.08
0.09
0.11
0.11
0.12
0.14
0.15
0.16
0.19
0.22
0.26
0.30
0.31
0.35
0.39
0.43
0.48
0.63
0.98
9
(229)
0.05
0.22
0.29
0.30
0.35
0.38
0.40
0.43
0.46
0.47
0.49
0.52
0.56
0.57
0.64
0.72
0.80
0.87
0.88
0.95
1.00
12
(305)
0.03
0.14
0.19
0.20
0.23
0.29
0.33
0.35
0.37
0.37
0.39
0.41
0.43
0.43
0.47
0.52
0.58
0.63
0.64
0.69
0.75
0.81
0.86
1.00
Concrete thickness
factor in shear5
HV
20
(508)
0.01
0.07
0.09
0.09
0.11
0.13
0.16
0.19
0.21
0.22
0.24
0.28
0.31
0.31
0.33
0.36
0.38
0.40
0.41
0.43
0.45
0.48
0.51
0.61
0.81
9
(229)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.60
0.63
0.65
0.66
0.70
0.74
0.78
0.82
0.82
0.85
0.89
0.92
0.95
1.00
12
(305)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.64
0.67
0.71
0.71
0.74
0.77
0.80
0.83
0.91
1.00
20
(508)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.60
0.62
0.64
0.70
0.81
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
4
5
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
9
12
20
9
12
20
9
12
20
9
12
20
9
12
20
9
12
20
in.
(mm) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508) (229) (305) (508)
1-3/4 (44)
n/a
n/a
n/a
0.42
0.40
0.38
n/a
n/a
n/a
0.02
0.02
0.01
0.05
0.03
0.02
n/a
n/a
n/a
5
(127) 0.59
0.57
0.54
0.55
0.50
0.44
0.54
0.53
0.52
0.11
0.08
0.05
0.22
0.16
0.09
n/a
n/a
n/a
6
(152) 0.61
0.58
0.55
0.59
0.53
0.46
0.55
0.54
0.53
0.14
0.10
0.06
0.29
0.21
0.12
n/a
n/a
n/a
6-1/4 (159) 0.61
0.59
0.55
0.60
0.54
0.46
0.55
0.54
0.53
0.15
0.11
0.07
0.31
0.22
0.13
n/a
n/a
n/a
7
(178) 0.63
0.60
0.56
0.64
0.57
0.47
0.55
0.54
0.53
0.18
0.13
0.08
0.36
0.26
0.16
n/a
n/a
n/a
8
(203) 0.64
0.61
0.57
0.69
0.60
0.49
0.56
0.55
0.53
0.22
0.16
0.09
0.44
0.32
0.19
n/a
n/a
n/a
9
(229) 0.66
0.63
0.58
0.74
0.64
0.51
0.57
0.55
0.54
0.26
0.19
0.11
0.53
0.38
0.23
n/a
n/a
n/a
10
(254) 0.68
0.64
0.58
0.79
0.67
0.53
0.58
0.56
0.54
0.31
0.22
0.13
0.62
0.44
0.26
n/a
n/a
n/a
11
(279) 0.70
0.65
0.59
0.84
0.71
0.55
0.58
0.57
0.55
0.36
0.25
0.15
0.72
0.51
0.31
n/a
n/a
n/a
11-1/4 (286) 0.70
0.66
0.59
0.85
0.72
0.56
0.59
0.57
0.55
0.37
0.26
0.16
0.74
0.53
0.32
0.59
n/a
n/a
12
(305) 0.72
0.67
0.60
0.89
0.75
0.57
0.59
0.57
0.55
0.41
0.29
0.17
0.82
0.58
0.35
0.61
n/a
n/a
13
(330) 0.73
0.68
0.61
0.95
0.79
0.59
0.60
0.58
0.56
0.46
0.33
0.20
0.92
0.65
0.39
0.63
n/a
n/a
14
(356) 0.75
0.69
0.62
1.00
0.83
0.62
0.61
0.59
0.56
0.51
0.37
0.22
1.00
0.73
0.44
0.65
n/a
n/a
14-1/4 (362) 0.76
0.70
0.62
0.84
0.62
0.61
0.59
0.56
0.53
0.38
0.23
0.75
0.45
0.66
0.59
n/a
16
(406) 0.79
0.72
0.63
0.91
0.66
0.62
0.60
0.57
0.63
0.45
0.27
0.89
0.54
0.70
0.62
n/a
18
(457) 0.82
0.75
0.65
1.00
0.70
0.64
0.61
0.58
0.75
0.53
0.32
1.00
0.64
0.74
0.66
n/a
20
(508) 0.86
0.78
0.67
0.75
0.65
0.62
0.59
0.88
0.62
0.37
0.75
0.78
0.70
n/a
22
(559) 0.89
0.81
0.68
0.80
0.67
0.63
0.60
1.00
0.72
0.43
0.80
0.82
0.73
n/a
22-1/4 (565) 0.90
0.81
0.69
0.80
0.67
0.64
0.60
0.73
0.44
0.80
0.82
0.74
0.62
24
(610) 0.93
0.83
0.70
0.85
0.68
0.65
0.60
0.82
0.49
0.85
0.86
0.76
0.64
26
(660) 0.97
0.86
0.72
0.90
0.70
0.66
0.61
0.93
0.56
0.90
0.89
0.80
0.67
28
(711) 1.00
0.89
0.73
0.95
0.71
0.67
0.62
1.00
0.62
0.95
0.92
0.83
0.70
30
(762)
0.92
0.75
1.00
0.73
0.68
0.63
0.69
1.00
0.96
0.85
0.72
36
(914)
1.00
0.80
0.77
0.72
0.66
0.90
1.00
0.94
0.79
> 48 (1219)
0.90
0.87
0.79
0.71
1.00
1.00
0.91
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Embedment
hef
1
2
3
Spacing factor
in tension
AN
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 113
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1-3/4
5-5/8
6
7
7-1/4
8
9
10
11
12
12-7/8
13
14
16
16-1/4
18
20
22
24
25-1/4
26
28
30
36
> 48
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
in. 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2
(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)
(44)
n/a
n/a
n/a
0.23
0.16
0.10
n/a
n/a
n/a
0.02
0.01
0.01
0.04
0.02
0.01
n/a
n/a
n/a
(143) 0.59
0.57
0.54
0.31
0.22
0.13
0.54
0.53
0.52
0.11
0.07
0.03
0.22
0.14
0.07
n/a
n/a
n/a
(152) 0.60
0.57
0.54
0.32
0.23
0.13
0.54
0.53
0.52
0.12
0.08
0.04
0.24
0.16
0.07
n/a
n/a
n/a
(178) 0.61
0.59
0.55
0.34
0.24
0.14
0.55
0.54
0.52
0.15
0.10
0.05
0.30
0.20
0.09
n/a
n/a
n/a
(184) 0.62
0.59
0.55
0.34
0.25
0.15
0.55
0.54
0.52
0.16
0.10
0.05
0.32
0.21
0.10
n/a
n/a
n/a
(203) 0.63
0.60
0.56
0.36
0.26
0.15
0.55
0.54
0.52
0.18
0.12
0.06
0.36
0.24
0.11
n/a
n/a
n/a
(229) 0.65
0.61
0.57
0.39
0.28
0.16
0.56
0.55
0.53
0.22
0.14
0.07
0.39
0.29
0.13
n/a
n/a
n/a
(254) 0.66
0.62
0.57
0.41
0.30
0.17
0.57
0.55
0.53
0.26
0.17
0.08
0.41
0.33
0.16
n/a
n/a
n/a
(279) 0.68
0.64
0.58
0.44
0.31
0.18
0.57
0.56
0.53
0.30
0.19
0.09
0.44
0.35
0.18
n/a
n/a
n/a
(305) 0.69
0.65
0.59
0.46
0.33
0.19
0.58
0.56
0.54
0.34
0.22
0.10
0.46
0.37
0.20
n/a
n/a
n/a
(327) 0.71
0.66
0.60
0.49
0.35
0.20
0.59
0.57
0.54
0.38
0.24
0.11
0.49
0.38
0.23
0.59
n/a
n/a
(330) 0.71
0.66
0.60
0.49
0.35
0.21
0.59
0.57
0.54
0.38
0.25
0.12
0.49
0.38
0.23
0.59
n/a
n/a
(356) 0.73
0.67
0.60
0.52
0.37
0.22
0.59
0.57
0.54
0.43
0.28
0.13
0.52
0.40
0.26
0.61
n/a
n/a
(406) 0.76
0.70
0.62
0.58
0.41
0.24
0.61
0.58
0.55
0.52
0.34
0.16
0.58
0.44
0.31
0.66
n/a
n/a
(413) 0.76
0.70
0.62
0.59
0.42
0.25
0.61
0.58
0.55
0.53
0.35
0.16
0.59
0.45
0.32
0.66
0.57
n/a
(457) 0.79
0.72
0.63
0.66
0.47
0.27
0.62
0.59
0.55
0.62
0.40
0.19
0.66
0.48
0.34
0.70
0.60
n/a
(508) 0.82
0.75
0.65
0.73
0.52
0.30
0.63
0.60
0.56
0.73
0.47
0.22
0.73
0.52
0.36
0.73
0.64
n/a
(559) 0.85
0.77
0.66
0.80
0.57
0.33
0.65
0.61
0.57
0.84
0.55
0.25
0.80
0.57
0.38
0.77
0.67
n/a
(610) 0.89
0.80
0.68
0.87
0.62
0.36
0.66
0.62
0.57
0.96
0.62
0.29
0.87
0.62
0.40
0.80
0.70
n/a
(641) 0.91
0.81
0.69
0.92
0.65
0.38
0.67
0.63
0.58
1.00
0.67
0.31
0.92
0.65
0.41
0.83
0.71
0.55
(660) 0.92
0.82
0.69
0.95
0.67
0.39
0.68
0.63
0.58
0.70
0.33
0.95
0.67
0.42
0.84
0.73
0.56
(711) 0.95
0.85
0.71
1.00
0.73
0.42
0.69
0.64
0.59
0.78
0.36
1.00
0.73
0.44
0.87
0.75
0.58
(762) 0.98
0.87
0.72
0.78
0.46
0.70
0.65
0.59
0.87
0.40
0.78
0.47
0.90
0.78
0.60
(914) 1.00
0.94
0.77
0.93
0.55
0.74
0.68
0.61
1.00
0.53
0.93
0.55
0.99
0.85
0.66
(1219)
1.00
0.86
1.00
0.73
0.82
0.74
0.65
0.82
1.00
0.73
1.00
0.99
0.76
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
in. 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2 10-1/8 13-1/2 22-1/2
(mm) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572) (257) (343) (572)
1-3/4 (44)
n/a
n/a
n/a
0.41
0.39
0.38
n/a
n/a
n/a
0.02
0.01
0.01
0.04
0.03
0.02
n/a
n/a
n/a
5-5/8 (143) 0.59
0.57
0.54
0.55
0.50
0.44
0.54
0.53
0.52
0.11
0.08
0.05
0.22
0.16
0.09
n/a
n/a
n/a
6
(152) 0.60
0.57
0.54
0.57
0.51
0.44
0.54
0.53
0.52
0.12
0.09
0.05
0.24
0.17
0.10
n/a
n/a
n/a
7
(178) 0.61
0.59
0.55
0.61
0.54
0.46
0.55
0.54
0.53
0.15
0.11
0.07
0.30
0.22
0.13
n/a
n/a
n/a
7-1/4 (184) 0.62
0.59
0.55
0.62
0.55
0.46
0.55
0.54
0.53
0.16
0.12
0.07
0.32
0.23
0.14
n/a
n/a
n/a
8
(203) 0.63
0.60
0.56
0.65
0.57
0.48
0.55
0.54
0.53
0.19
0.13
0.08
0.37
0.27
0.16
n/a
n/a
n/a
9
(229) 0.65
0.61
0.57
0.69
0.60
0.49
0.56
0.55
0.53
0.22
0.16
0.10
0.44
0.32
0.19
n/a
n/a
n/a
10
(254) 0.66
0.62
0.57
0.73
0.63
0.51
0.57
0.55
0.54
0.26
0.19
0.11
0.52
0.37
0.22
n/a
n/a
n/a
11
(279) 0.68
0.64
0.58
0.78
0.67
0.53
0.57
0.56
0.54
0.30
0.22
0.13
0.60
0.43
0.26
n/a
n/a
n/a
12
(305) 0.69
0.65
0.59
0.83
0.70
0.55
0.58
0.57
0.55
0.34
0.25
0.15
0.68
0.49
0.29
n/a
n/a
n/a
12-7/8 (327) 0.71
0.66
0.60
0.87
0.73
0.56
0.59
0.57
0.55
0.38
0.27
0.16
0.76
0.54
0.33
0.59
n/a
n/a
13
(330) 0.71
0.66
0.60
0.87
0.73
0.56
0.59
0.57
0.55
0.39
0.28
0.17
0.77
0.55
0.33
0.59
n/a
n/a
14
(356) 0.73
0.67
0.60
0.92
0.77
0.58
0.60
0.58
0.55
0.43
0.31
0.19
0.86
0.62
0.37
0.62
n/a
n/a
16
(406) 0.76
0.70
0.62
1.00
0.84
0.62
0.61
0.59
0.56
0.53
0.38
0.23
1.00
0.75
0.45
0.66
n/a
n/a
16-1/4 (413) 0.76
0.70
0.62
0.85
0.63
0.61
0.59
0.56
0.54
0.39
0.23
0.77
0.46
0.66
0.59
n/a
18
(457) 0.79
0.72
0.63
0.91
0.66
0.62
0.60
0.57
0.63
0.45
0.27
0.90
0.54
0.70
0.63
n/a
20
(508) 0.82
0.75
0.65
0.99
0.70
0.64
0.61
0.58
0.73
0.53
0.32
0.99
0.63
0.74
0.66
n/a
22
(559) 0.85
0.77
0.66
1.00
0.74
0.65
0.62
0.59
0.85
0.61
0.36
1.00
0.73
0.77
0.69
n/a
24
(610) 0.89
0.80
0.68
0.78
0.66
0.63
0.59
0.97
0.69
0.42
0.78
0.81
0.72
n/a
25-1/4 (641) 0.91
0.81
0.69
0.81
0.67
0.64
0.60
1.00
0.75
0.45
0.81
0.83
0.74
0.63
26
(660) 0.92
0.82
0.69
0.82
0.68
0.64
0.60
0.78
0.47
0.82
0.84
0.75
0.63
28
(711) 0.95
0.85
0.71
0.87
0.69
0.65
0.61
0.87
0.52
0.87
0.87
0.78
0.66
30
(762) 0.98
0.87
0.72
0.91
0.70
0.66
0.62
0.97
0.58
0.91
0.90
0.81
0.68
36
(914) 1.00
0.94
0.77
1.00
0.74
0.70
0.64
1.00
0.76
1.00
0.99
0.88
0.75
> 48 (1219)
1.00
0.86
0.83
0.76
0.69
1.00
1.00
1.00
0.86
Linear interpolation not permitted.
Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1
2
3
4
5
114 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment
hef
1-3/4
6-1/4
7
8
9
10
11
12
13
14
14-1/4
15
16
17
18
20
22
24
26
28
30
36
> 48
Spacing factor
in tension
AN
in. 11-1/4 15
(mm) (286) (381)
(44)
n/a
n/a
(159) 0.59
0.57
(178) 0.60
0.58
(203) 0.62
0.59
(229) 0.63
0.60
(254) 0.65
0.61
(279) 0.66
0.62
(305) 0.68
0.63
(330) 0.69
0.64
(356) 0.71
0.66
(362) 0.71
0.66
(381) 0.72
0.67
(406) 0.73
0.68
(432) 0.75
0.69
(457) 0.76
0.70
(508) 0.79
0.72
(559) 0.82
0.74
(610) 0.85
0.77
(660) 0.88
0.79
(711) 0.91
0.81
(762) 0.94
0.83
(914) 1.00
0.90
(1219)
1.00
25
11-1/4 15
(635) (286) (381)
n/a
0.23
0.16
0.54
0.31
0.22
0.55
0.33
0.23
0.55
0.35
0.25
0.56
0.37
0.26
0.57
0.39
0.28
0.57
0.42
0.29
0.58
0.44
0.31
0.59
0.47
0.33
0.59
0.49
0.35
0.60
0.50
0.35
0.60
0.52
0.36
0.61
0.54
0.38
0.61
0.57
0.40
0.62
0.60
0.42
0.63
0.67
0.47
0.65
0.74
0.52
0.66
0.80
0.56
0.67
0.87
0.61
0.69
0.94
0.66
0.70
1.00
0.71
0.74
0.85
0.82
1.00
Spacing factor
in shear4
AV
25
11-1/4 15
(635) (286) (381)
0.09
n/a
n/a
0.13
0.54
0.53
0.14
0.54
0.53
0.14
0.55
0.54
0.15
0.55
0.54
0.16
0.56
0.55
0.17
0.57
0.55
0.18
0.57
0.55
0.19
0.58
0.56
0.20
0.59
0.56
0.20
0.59
0.56
0.21
0.59
0.57
0.22
0.60
0.57
0.23
0.60
0.58
0.25
0.61
0.58
0.28
0.62
0.59
0.30
0.63
0.60
0.33
0.65
0.61
0.36
0.66
0.62
0.39
0.67
0.63
0.41
0.68
0.64
0.50
0.72
0.66
0.66
0.79
0.72
Toward edge
RV
25
11-1/4 15
(635) (286) (381)
n/a
0.02
0.01
0.52
0.11
0.07
0.52
0.13
0.08
0.52
0.16
0.10
0.52
0.19
0.12
0.53
0.22
0.14
0.53
0.25
0.16
0.53
0.29
0.19
0.54
0.33
0.21
0.54
0.36
0.24
0.54
0.37
0.24
0.54
0.40
0.26
0.54
0.45
0.29
0.55
0.49
0.32
0.55
0.53
0.35
0.55
0.62
0.40
0.56
0.72
0.47
0.57
0.82
0.53
0.57
0.92
0.60
0.58
1.00
0.67
0.58
0.74
0.60
0.98
0.63
1.00
To edge
RV
25
11-1/4 15
(635) (286) (381)
0.00
0.03
0.02
0.03
0.22
0.14
0.04
0.26
0.17
0.05
0.31
0.20
0.06
0.37
0.24
0.07
0.39
0.29
0.08
0.42
0.33
0.09
0.44
0.35
0.10
0.47
0.36
0.11
0.49
0.38
0.11
0.50
0.38
0.12
0.52
0.40
0.13
0.54
0.41
0.15
0.57
0.43
0.16
0.60
0.45
0.19
0.67
0.48
0.22
0.74
0.52
0.25
0.80
0.56
0.28
0.87
0.61
0.31
0.94
0.66
0.35
1.00
0.71
0.45
0.85
0.70
1.00
Concrete thickness
factor in shear5
HV
25
11-1/4 15
(635) (286) (381)
0.01
n/a
n/a
0.07
n/a
n/a
0.08
n/a
n/a
0.10
n/a
n/a
0.11
n/a
n/a
0.13
n/a
n/a
0.15
n/a
n/a
0.17
n/a
n/a
0.20
n/a
n/a
0.22
n/a
n/a
0.23
0.59
n/a
0.24
0.60
n/a
0.27
0.62
n/a
0.29
0.64
n/a
0.32
0.66
0.57
0.34
0.70
0.60
0.36
0.73
0.63
0.38
0.76
0.66
0.40
0.79
0.69
0.42
0.82
0.71
0.44
0.85
0.74
0.50
0.94
0.81
0.66
1.00
0.94
25
(635)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.63
0.72
3.2.3
3.2.5
3.2.4
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
25
11-1/4 15
25
11-1/4 15
25
11-1/4 15
25
11-1/4 15
25
11-1/4 15
25
in. 11-1/4 15
Embedment
hef
(mm) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635) (286) (381) (635)
1-3/4 (44)
n/a
n/a
n/a
0.40
0.39
0.37
n/a
n/a
n/a
0.02
0.01
0.01
0.03
0.02
0.01
n/a
n/a
n/a
6-1/4 (159) 0.59
0.57
0.54
0.55
0.50
0.44
0.54
0.53
0.52
0.11
0.08
0.05
0.22
0.16
0.10
n/a
n/a
n/a
7
(178) 0.60
0.58
0.55
0.58
0.52
0.45
0.54
0.54
0.53
0.13
0.10
0.06
0.26
0.19
0.12
n/a
n/a
n/a
8
(203) 0.62
0.59
0.55
0.62
0.55
0.46
0.55
0.54
0.53
0.16
0.12
0.07
0.32
0.24
0.14
n/a
n/a
n/a
9
(229) 0.63
0.60
0.56
0.66
0.57
0.48
0.55
0.55
0.53
0.19
0.14
0.08
0.38
0.28
0.17
n/a
n/a
n/a
10
(254) 0.65
0.61
0.57
0.69
0.60
0.49
0.56
0.55
0.54
0.22
0.17
0.10
0.44
0.33
0.20
n/a
n/a
n/a
11
(279) 0.66
0.62
0.57
0.74
0.63
0.51
0.57
0.56
0.54
0.26
0.19
0.11
0.51
0.38
0.23
n/a
n/a
n/a
12
(305) 0.68
0.63
0.58
0.78
0.66
0.53
0.57
0.56
0.54
0.29
0.22
0.13
0.58
0.44
0.26
n/a
n/a
n/a
13
(330) 0.69
0.64
0.59
0.82
0.69
0.54
0.58
0.57
0.55
0.33
0.25
0.15
0.66
0.49
0.29
n/a
n/a
n/a
14
(356) 0.71
0.66
0.59
0.86
0.72
0.56
0.59
0.57
0.55
0.37
0.27
0.16
0.73
0.55
0.33
n/a
n/a
n/a
14-1/4 (362) 0.71
0.66
0.60
0.87
0.73
0.56
0.59
0.57
0.55
0.38
0.28
0.17
0.75
0.56
0.34
0.59
n/a
n/a
15
(381) 0.72
0.67
0.60
0.91
0.75
0.57
0.59
0.58
0.55
0.41
0.30
0.18
0.82
0.61
0.36
0.61
n/a
n/a
16
(406) 0.73
0.68
0.61
0.95
0.78
0.59
0.60
0.58
0.56
0.45
0.33
0.20
0.90
0.67
0.40
0.63
n/a
n/a
17
(432) 0.75
0.69
0.61
1.00
0.81
0.61
0.60
0.59
0.56
0.49
0.37
0.22
0.98
0.73
0.44
0.64
n/a
n/a
18
(457) 0.76
0.70
0.62
0.85
0.62
0.61
0.59
0.56
0.54
0.40
0.24
1.00
0.80
0.48
0.66
0.60
n/a
20
(508) 0.79
0.72
0.63
0.91
0.66
0.62
0.60
0.57
0.63
0.47
0.28
0.91
0.56
0.70
0.63
n/a
22
(559) 0.82
0.74
0.65
0.98
0.69
0.63
0.61
0.58
0.72
0.54
0.32
0.98
0.65
0.73
0.66
n/a
24
(610) 0.85
0.77
0.66
1.00
0.73
0.65
0.62
0.59
0.82
0.62
0.37
1.00
0.73
0.77
0.69
n/a
26
(660) 0.88
0.79
0.67
0.77
0.66
0.63
0.59
0.93
0.69
0.42
0.77
0.80
0.72
n/a
28
(711) 0.91
0.81
0.69
0.81
0.67
0.64
0.60
1.00
0.78
0.47
0.81
0.83
0.75
0.63
30
(762) 0.94
0.83
0.70
0.85
0.68
0.65
0.61
0.86
0.52
0.85
0.86
0.78
0.65
36
(914) 1.00
0.90
0.74
0.97
0.72
0.68
0.63
1.00
0.68
0.97
0.94
0.85
0.72
> 48 (1219)
1.00
0.82
1.00
0.79
0.74
0.67
1.00
1.00
1.00
0.98
0.83
1 Linear interpolation not permitted.
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 115
Symbol Units
do
hef,std
minimum
hef,min
maximum
hef,max
Effective
embedment
Minimum diameter
through-set
of fixture hole
Minimum diameter
preset
of fixture hole
Installation torque
Tinst
3/8
1/2
in.
7/16
9/16
in.
(mm)
in.
(mm)
(86)
3/4
7/8
1-1/4
1-1/8 1-3/8
9
11-1/4
(70)
(79)
(89)
(89)
(102) (127)
in.
1/2
5/8
in.
7/16
ft-lb
(Nm)
15
(20)
30
(40)
60
(80)
100
125
150
200
(136) (169) (203) (271)
116 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3/8
1/2
5/8
3/4
7/8
1-1/4
1
2
3
4
5
6
7
8
9
Effective
embedment
in. (mm)
2-3/8
(60)
3-3/8
(86)
4-1/2
(114)
7-1/2
(191)
2-3/4
(70)
4-1/2
(114)
6
(152)
10
(254)
3-1/8
(79)
5-5/8
(143)
7-1/2
(191)
12-1/2
(318)
3-1/2
(89)
6-3/4
(171)
9
(229)
15
(381)
3-1/2
(89)
7-7/8
(200)
10-1/2
(267)
17-1/2
(445)
4
(102)
9
(229)
12
(305)
20
(508)
5
(127)
11-1/4
(286)
15
(381)
25
(635)
c = 2500 psi
(17.2 Mpa)
lb (kN)
2,855
(12.7)
4,835
(21.5)
7,445
(33.1)
13,125
(58.4)
3,555
(15.8)
7,445
(33.1)
11,465
(51.0)
22,820
(101.5)
4,310
(19.2)
10,405
(46.3)
16,020
(71.3)
34,140
(151.9)
5,105
(22.7)
13,680
(60.9)
21,060
(93.7)
45,315
(201.6)
5,105
(22.7)
17,235
(76.7)
26,540
(118.1)
52,915
(235.4)
6,240
(27.8)
21,060
(93.7)
32,425
(144.2)
67,215
(299.0)
8,720
(38.8)
29,430
(130.9)
45,315
(201.6)
97,500
(433.7)
Tension Nn or Nr
c = 3000 psi
c = 4000 psi
(20.7 Mpa)
(27.6 Mpa)
lb (kN)
lb (kN)
3,125
3,610
(13.9)
(16.1)
5,300
5,905
(23.6)
(26.3)
7,875
7,875
(35.0)
(35.0)
13,125
13,125
(58.4)
(58.4)
3,895
4,500
(17.3)
(20.0)
8,155
9,420
(36.3)
(41.9)
12,560
13,690
(55.9)
(60.9)
22,820
22,820
(101.5)
(101.5)
4,720
5,450
(21.0)
(24.2)
11,400
13,165
(50.7)
(58.6)
17,550
20,265
(78.1)
(90.1)
34,140
34,140
(151.9)
(151.9)
5,595
6,460
(24.9)
(28.7)
14,985
17,305
(66.7)
(77.0)
23,070
26,640
(102.6)
(118.5)
47,440
47,440
(211.0)
(211.0)
5,595
6,460
(24.9)
(28.7)
18,885
21,805
(84.0)
(97.0)
29,070
31,750
(129.3)
(141.2)
52,915
52,915
(235.4)
(235.4)
6,835
7,895
(30.4)
(35.1)
23,070
26,640
(102.6)
(118.5)
35,520
40,330
(158.0)
(179.4)
67,215
67,215
(299.0)
(299.0)
9,555
11,030
(42.5)
(49.1)
32,240
37,230
(143.4)
(165.6)
49,640
57,320
(220.8)
(255.0)
100,435
100,435
(446.8)
(446.8)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4,405
(19.6)
6,260
(27.8)
8,345
(37.1)
13,910
(61.9)
5,510
(24.5)
10,885
(48.4)
14,515
(64.6)
24,190
(107.6)
6,675
(29.7)
16,120
(71.7)
21,715
(96.6)
36,190
(161.0)
7,910
(35.2)
21,190
(94.3)
30,170
(134.2)
50,285
(223.7)
7,910
(35.2)
25,240
(112.3)
33,655
(149.7)
56,090
(249.5)
9,665
(43.0)
32,060
(142.6)
42,750
(190.2)
71,245
(316.9)
13,510
(60.1)
45,595
(202.8)
63,875
(284.1)
106,460
(473.6)
c = 2500 psi
(17.2 Mpa)
lb (kN)
3,075
(13.7)
10,415
(46.3)
16,035
(71.3)
28,265
(125.7)
7,660
(34.1)
16,035
(71.3)
24,690
(109.8)
49,150
(218.6)
9,280
(41.3)
22,415
(99.7)
34,505
(153.5)
73,535
(327.1)
11,000
(48.9)
29,460
(131.0)
45,360
(201.8)
97,600
(434.1)
11,000
(48.9)
37,125
(165.1)
57,160
(254.3)
122,990
(547.1)
13,440
(59.8)
45,360
(201.8)
69,835
(310.6)
150,265
(668.4)
18,785
(83.6)
63,395
(282.0)
97,600
(434.1)
210,000
(934.1)
Shear Vn or Vr
c = 3000 psi
c = 4000 psi
(20.7 Mpa)
(27.6 Mpa)
lb (kN)
lb (kN)
3,370
3,890
(15.0)
(17.3)
11,410
12,720
(50.8)
(56.6)
16,960
16,960
(75.4)
(75.4)
28,265
28,265
(125.7)
(125.7)
8,395
9,690
(37.3)
(43.1)
17,570
20,285
(78.2)
(90.2)
27,045
29,490
(120.3)
(131.2)
49,150
49,150
(218.6)
(218.6)
10,165
11,740
(45.2)
(52.2)
24,550
28,350
(109.2)
(126.1)
37,800
43,650
(168.1)
(194.2)
73,535
73,535
(327.1)
(327.1)
12,050
13,915
(53.6)
(61.9)
32,275
37,265
(143.6)
(165.8)
49,690
57,375
(221.0)
(255.2)
102,175
102,175
(454.5)
(454.5)
12,050
13,915
(53.6)
(61.9)
40,670
46,960
(180.9)
(208.9)
62,615
72,300
(278.5)
(321.6)
134,695
134,695
(599.2)
(599.2)
14,725
17,000
(65.5)
(75.6)
49,690
57,375
(221.0)
(255.2)
76,500
88,335
(340.3)
(392.9)
164,605
171,090
(732.2)
(761.0)
20,575
23,760
(91.5)
(105.7)
69,445
80,185
(308.9)
(356.7)
106,915
123,455
(475.6)
(549.2)
230,045
255,645
(1023.3)
(1137.2)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4,745
(21.1)
13,485
(60.0)
17,975
(80.0)
29,960
(133.3)
11,870
(52.8)
23,445
(104.3)
31,260
(139.1)
52,100
(231.8)
14,380
(64.0)
34,720
(154.4)
46,765
(208.0)
77,945
(346.7)
17,040
(75.8)
45,645
(203.0)
64,985
(289.1)
108,305
(481.8)
17,040
(75.8)
57,515
(255.8)
85,665
(381.1)
142,780
(635.1)
20,820
(92.6)
70,270
(312.6)
108,190
(481.3)
181,355
(806.7)
29,100
(129.4)
98,205
(436.8)
151,200
(672.6)
270,985
(1205.4)
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 117
3/8
1/2
5/8
3/4
7/8
1-1/4
Effective
embedment
depth
in. (mm)
2-3/8
(60)
3-3/8
(86)
4-1/2
(114)
7-1/2
(191)
2-3/4
(70)
4-1/2
(114)
6
(152)
10
(254)
3-1/8
(79)
5-5/8
(143)
7-1/2
(191)
12-1/2
(318)
3-1/2
(89)
6-3/4
(171)
9
(229)
15
(381)
3-1/2
(89)
7-7/8
(200)
10-1/2
(267)
17-1/2
(445)
4
(102)
9
(229)
12
(305)
20
(508)
5
(127)
11-1/4
(286)
15
(381)
25
(635)
c = 2500 psi
(17.2 Mpa)
lb (kN)
1,980
(8.8)
2,815
(12.5)
3,755
(16.7)
6,260
(27.8)
2,520
(11.2)
4,940
(22.0)
6,585
(29.3)
10,975
(48.8)
3,050
(13.6)
7,370
(32.8)
10,005
(44.5)
16,670
(74.2)
3,620
(16.1)
9,690
(43.1)
13,785
(61.3)
22,975
(102.2)
3,620
(16.1)
10,955
(48.7)
14,605
(65.0)
24,340
(108.3)
4,420
(19.7)
13,220
(58.8)
17,625
(78.4)
29,375
(130.7)
6,175
(27.5)
17,740
(78.9)
23,650
(105.2)
39,415
(175.3)
Tension Nn or Nr
c = 3000 psi
c = 4000 psi
(20.7 Mpa)
(27.6 Mpa)
lb (kN)
lb (kN)
1,980
1,980
(8.8)
(8.8)
2,815
2,815
(12.5)
(12.5)
3,755
3,755
(16.7)
(16.7)
6,260
6,260
(27.8)
(27.8)
2,760
3,020
(12.3)
(13.4)
4,940
4,940
(22.0)
(22.0)
6,585
6,585
(29.3)
(29.3)
10,975
10,975
(48.8)
(48.8)
3,345
3,860
(14.9)
(17.2)
7,500
7,500
(33.4)
(33.4)
10,005
10,005
(44.5)
(44.5)
16,670
16,670
(74.2)
(74.2)
3,965
4,575
(17.6)
(20.4)
10,340
10,340
(46.0)
(46.0)
13,785
13,785
(61.3)
(61.3)
22,975
22,975
(102.2)
(102.2)
3,965
4,575
(17.6)
(20.4)
10,955
10,955
(48.7)
(48.7)
14,605
14,605
(65.0)
(65.0)
24,340
24,340
(108.3)
(108.3)
4,840
5,590
(21.5)
(24.9)
13,220
13,220
(58.8)
(58.8)
17,625
17,625
(78.4)
(78.4)
29,375
29,375
(130.7)
(130.7)
6,765
7,815
(30.1)
(34.8)
17,740
17,740
(78.9)
(78.9)
23,650
23,650
(105.2)
(105.2)
39,415
39,415
(175.3)
(175.3)
c = 6000 psi
(41.4 Mpa)
lb (kN)
2,100
(9.3)
2,985
(13.3)
3,980
(17.7)
6,635
(29.5)
3,200
(14.2)
5,235
(23.3)
6,980
(31.0)
11,635
(51.8)
4,420
(19.7)
7,950
(35.4)
10,605
(47.2)
17,670
(78.6)
5,605
(24.9)
10,960
(48.8)
14,610
(65.0)
24,350
(108.3)
5,160
(23.0)
11,610
(51.6)
15,480
(68.9)
25,800
(114.8)
6,225
(27.7)
14,010
(62.3)
18,680
(83.1)
31,135
(138.5)
8,355
(37.2)
18,800
(83.6)
25,070
(111.5)
41,780
(185.8)
c = 2500 psi
(17.2 Mpa)
lb (kN)
2,135
(9.5)
6,065
(27.0)
8,090
(36.0)
13,485
(60.0)
5,425
(24.1)
10,640
(47.3)
14,185
(63.1)
23,640
(105.2)
6,575
(29.2)
15,875
(70.6)
21,545
(95.8)
35,905
(159.7)
7,790
(34.7)
20,870
(92.8)
29,690
(132.1)
49,480
(220.1)
7,790
(34.7)
26,300
(117.0)
37,175
(165.4)
61,960
(275.6)
9,520
(42.3)
32,130
(142.9)
44,860
(199.5)
74,770
(332.6)
13,305
(59.2)
44,905
(199.7)
60,200
(267.8)
100,335
(446.3)
Shear Vn or Vr
c = 3000 psi
c = 4000 psi
(20.7 Mpa)
(27.6 Mpa)
lb (kN)
lb (kN)
2,135
2,135
(9.5)
(9.5)
6,065
6,065
(27.0)
(27.0)
8,090
8,090
(36.0)
(36.0)
13,485
13,485
(60.0)
(60.0)
5,945
6,500
(26.4)
(28.9)
10,640
10,640
(47.3)
(47.3)
14,185
14,185
(63.1)
(63.1)
23,640
23,640
(105.2)
(105.2)
7,200
8,315
(32.0)
(37.0)
16,160
16,160
(71.9)
(71.9)
21,545
21,545
(95.8)
(95.8)
35,905
35,905
(159.7)
(159.7)
8,535
9,855
(38.0)
(43.8)
22,265
22,265
(99.0)
(99.0)
29,690
29,690
(132.1)
(132.1)
49,480
49,480
(220.1)
(220.1)
8,535
9,855
(38.0)
(43.8)
27,880
27,880
(124.0)
(124.0)
37,175
37,175
(165.4)
(165.4)
61,960
61,960
(275.6)
(275.6)
10,430
12,040
(46.4)
(53.6)
33,645
33,645
(149.7)
(149.7)
44,860
44,860
(199.5)
(199.5)
74,770
74,770
(332.6)
(332.6)
14,575
16,830
(64.8)
(74.9)
45,150
45,150
(200.8)
(200.8)
60,200
60,200
(267.8)
(267.8)
100,335
100,335
(446.3)
(446.3)
c = 6000 psi
(41.4 Mpa)
lb (kN)
2,265
(10.1)
6,430
(28.6)
8,575
(38.1)
14,290
(63.6)
6,890
(30.6)
11,275
(50.2)
15,035
(66.9)
25,060
(111.5)
9,515
(42.3)
17,130
(76.2)
22,835
(101.6)
38,060
(169.3)
12,070
(53.7)
23,600
(105.0)
31,470
(140.0)
52,450
(233.3)
12,070
(53.7)
29,555
(131.5)
39,405
(175.3)
65,680
(292.2)
14,750
(65.6)
35,665
(158.6)
47,555
(211.5)
79,255
(352.5)
20,610
(91.7)
47,860
(212.9)
63,815
(283.9)
106,355
(473.1)
1
2
3
4
HAS-E 2
3
Tensile
Nsa
lb (kN)
Shear
Vsa
lb (kN)
Seismic Shear
Vsa
lb (kN)
3,655
(16.3)
6,690
(29.8)
10,650
(47.4)
15,765
(70.1)
21,755
(96.8)
28,540
(127.0)
45,670
(203.1)
1,685
(7.5)
3,705
(16.5)
5,900
(26.2)
8,730
(38.8)
12,050
(53.6)
15,805
(70.3)
25,295
(112.5)
1,180
(5.2)
2,594
(11.5)
4,130
(18.4)
6,111
(27.2)
8,435
(37.5)
11,064
(49.2)
17,707
(78.8)
Tensile
Nsa
lb (kN)
Shear
Vsa
lb (kN)
Seismic Shear
Vsa
lb (kN)
7,265
(32.3)
13,300
(59.2)
21,190
(94.3)
31,360
(139.5)
43,285
(192.5)
56,785
(252.6)
90,850
(404.1)
3,150
(14.0)
6,915
(30.8)
11,020
(49.0)
16,305
(72.5)
22,505
(100.1)
29,525
(131.3)
47,240
(210.1)
2,205
(9.8)
4,841
(21.5)
7,714
(34.3)
11,414
(50.8)
15,754
(70.1)
20,668
(91.9)
33,068
(147.1)
Tensile
Nsa
lb (kN)
Shear4
Vsa
lb (kN)
Seismic Shear5
Vsa
lb (kN)
5,040
(22.4)
9,225
(41.0)
14,690
(65.3)
18,480
(82.2)
25,510
(113.5)
33,465
(148.9)
53,540
(238.2)
2,325
(10.3)
5,110
(22.7)
8,135
(36.2)
10,235
(45.5)
14,125
(62.8)
18,535
(82.4)
29,655
(131.9)
1,628
(7.2)
3,577
(15.9)
5,695
(25.3)
7,165
(31.9)
9,888
(44.0)
12,975
(57.7)
20,759
(92.3)
See Section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
HAS Super rods are considered ductile steel elements. HAS-E and HAS SS rods are considered brittle steel elements.
Tensile = Ase,N futa as noted in ACI 318 Appendix D
Shear = 0.60 Ase,N futa as noted in ACI 318 Appendix D
Seismic shear values determined by multiplying Vsa x V,seis where V,seis = 0.7 for threaded rod. See Section 3.1.7.4 for additional information on seismic applications.
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 119
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
1-7/8 (48)
2
(51)
3
(76)
3-5/8 (92)
4
(102)
4-5/8 (117)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
8
(203)
8-3/4 (222)
9
(229)
10 (254)
11 (279)
12 (305)
14 (356)
16 (406)
18 (457)
24 (610)
30 (762)
36 (914)
> 48 (1219)
Spacing factor
in tension
AN
2-3/8
(60)
n/a
0.58
0.59
0.63
0.66
0.68
0.70
0.72
0.75
0.76
0.81
0.85
0.89
0.90
0.94
0.99
1.00
3-3/8
(86)
n/a
0.58
0.59
0.63
0.66
0.68
0.70
0.72
0.75
0.76
0.81
0.85
0.89
0.90
0.94
0.99
1.00
4-1/2
(114)
n/a
0.57
0.57
0.61
0.63
0.65
0.67
0.69
0.71
0.72
0.76
0.80
0.82
0.83
0.87
0.91
0.94
1.00
7-1/2
(191)
n/a
0.54
0.54
0.57
0.58
0.59
0.60
0.61
0.63
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.81
0.86
0.90
1.00
3-3/8
(86)
0.28
0.29
0.29
0.36
0.40
0.43
0.48
0.51
0.58
0.61
0.71
0.81
0.89
0.91
1.00
4-1/2
(114)
0.22
0.22
0.23
0.28
0.31
0.33
0.36
0.38
0.43
0.44
0.52
0.59
0.65
0.67
0.74
0.81
0.89
1.00
7-1/2
(191)
0.13
0.13
0.13
0.16
0.18
0.19
0.21
0.22
0.25
0.26
0.30
0.34
0.38
0.39
0.43
0.47
0.51
0.60
0.69
0.77
1.00
Spacing factor
in shear4
AV
2-3/8
(60)
n/a
0.57
0.57
0.61
0.63
0.64
0.66
0.68
0.70
0.71
0.75
0.79
0.81
0.82
0.86
0.89
0.93
1.00
3-3/8
(86)
n/a
0.53
0.53
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.68
0.70
0.73
0.76
0.79
0.89
0.99
1.00
4-1/2
(114)
n/a
0.52
0.52
0.54
0.54
0.55
0.56
0.56
0.57
0.57
0.59
0.60
0.61
0.61
0.62
0.63
0.65
0.67
0.70
0.72
0.79
0.87
0.94
1.00
7-1/2
(191)
n/a
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.65
0.70
0.75
0.80
0.90
To edge
RV
Toward edge
RV
2-3/8
(60)
0.23
0.25
0.28
0.51
0.68
0.79
0.98
1.00
3-3/8
(86)
0.07
0.08
0.09
0.16
0.21
0.24
0.30
0.34
0.42
0.45
0.57
0.69
0.79
0.83
0.97
1.00
4-1/2
(114)
0.05
0.05
0.06
0.10
0.14
0.16
0.20
0.22
0.27
0.29
0.37
0.45
0.51
0.54
0.63
0.72
0.83
1.00
7-1/2
(191)
0.03
0.03
0.03
0.06
0.08
0.09
0.11
0.13
0.16
0.17
0.21
0.25
0.29
0.30
0.36
0.41
0.47
0.59
0.72
0.86
1.00
2-3/8
(60)
0.41
0.35
0.37
0.48
0.55
0.61
0.70
0.76
0.87
0.91
1.00
3-3/8
(86)
0.14
0.16
0.17
0.32
0.40
0.43
0.48
0.51
0.58
0.61
0.71
0.81
0.89
0.91
1.00
4-1/2
(114)
0.09
0.10
0.11
0.21
0.27
0.32
0.38
0.40
0.44
0.46
0.52
0.59
0.65
0.67
0.74
0.81
0.89
1.00
Concrete thickness
factor in shear5
HV
7-1/2
(191)
0.05
0.06
0.06
0.12
0.16
0.18
0.22
0.25
0.31
0.32
0.35
0.38
0.40
0.41
0.44
0.47
0.51
0.60
0.69
0.77
1.00
2-3/8
(60)
n/a
n/a
n/a
n/a
0.72
0.75
0.81
0.84
0.91
0.92
1.00
3-3/8
(86)
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.61
0.63
0.68
0.72
0.76
0.77
0.81
0.85
0.88
0.96
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.53
0.54
0.58
0.63
0.65
0.66
0.70
0.73
0.77
0.83
0.88
0.94
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.55
0.58
0.61
0.63
0.68
0.73
0.78
0.90
1.00
Table 27 - Load adjustment factors for 3/8-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
3/8-in.
cracked
concrete
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in. 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2 2-3/8 3-3/8 4-1/2 7-1/2
hef
(mm) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191) (60) (86) (114) (191)
1-3/4 (44) n/a n/a n/a n/a 0.52 0.52 0.49 0.43 n/a n/a n/a n/a 0.24 0.09 0.07 0.04 0.47 0.17 0.13 0.08 n/a n/a n/a n/a
1-7/8 (48) 0.58 0.58 0.57 0.54 0.53 0.53 0.50 0.44 0.57 0.53 0.53 0.52 0.26 0.10 0.07 0.04 0.52 0.19 0.14 0.09 n/a n/a n/a n/a
2
(51) 0.59 0.59 0.57 0.54 0.55 0.55 0.51 0.44 0.57 0.54 0.53 0.52 0.29 0.11 0.08 0.05 0.58 0.21 0.16 0.10 n/a n/a n/a n/a
3
(76) 0.63 0.63 0.61 0.57 0.66 0.66 0.60 0.49 0.61 0.56 0.55 0.53 0.53 0.19 0.15 0.09 0.88 0.39 0.29 0.18 n/a n/a n/a n/a
3-5/8 (92) 0.66 0.66 0.63 0.58 0.73 0.73 0.66 0.53 0.63 0.57 0.56 0.54 0.70 0.26 0.19 0.12 1.00 0.52 0.39 0.23 0.73 n/a n/a n/a
4
(102) 0.68 0.68 0.65 0.59 0.78 0.78 0.70 0.55 0.65 0.57 0.56 0.54 0.81 0.30 0.22 0.13
0.60 0.45 0.27 0.76 n/a n/a n/a
4-5/8 (117) 0.70 0.70 0.67 0.60 0.86 0.86 0.76 0.58 0.67 0.59 0.57 0.55 1.00 0.37 0.28 0.17
0.75 0.56 0.34 0.82 0.59 n/a n/a
5
(127) 0.72 0.72 0.69 0.61 0.91 0.91 0.80 0.60 0.68 0.59 0.58 0.55
0.42 0.31 0.19
0.84 0.63 0.38 0.85 0.61 n/a n/a
5-3/4 (146) 0.75 0.75 0.71 0.63 1.00 1.00 0.88 0.64 0.71 0.61 0.59 0.56
0.52 0.39 0.23
1.00 0.78 0.47 0.91 0.66 0.60 n/a
6
(152) 0.76 0.76 0.72 0.63
0.91 0.66 0.72 0.61 0.59 0.57
0.55 0.41 0.25
0.83 0.50 0.93 0.67 0.61 n/a
7
(178) 0.81 0.81 0.76 0.66
1.00 0.72 0.75 0.63 0.61 0.58
0.69 0.52 0.31
1.00 0.62 1.00 0.72 0.66 n/a
8
(203) 0.85 0.85 0.80 0.68
0.78 0.79 0.65 0.62 0.59
0.85 0.64 0.38
0.76
0.77 0.70 n/a
8-3/4 (222) 0.89 0.89 0.82 0.69
0.83 0.82 0.66 0.63 0.60
0.97 0.73 0.44
0.83
0.81 0.73 0.62
9
(229) 0.90 0.90 0.83 0.70
0.85 0.83 0.67 0.64 0.60
1.00 0.76 0.46
0.85
0.82 0.74 0.63
10 (254) 0.94 0.94 0.87 0.72
0.91 0.86 0.69 0.65 0.61
0.89 0.53
0.91
0.86 0.79 0.66
11 (279) 0.99 0.99 0.91 0.74
0.98 0.90 0.71 0.67 0.62
1.00 0.62
0.98
0.91 0.82 0.69
12 (305) 1.00 1.00 0.94 0.77
1.00 0.94 0.72 0.68 0.63
0.70
1.00
0.95 0.86 0.73
14 (356)
1.00 1.00 0.81
1.00 0.76 0.72 0.65
0.88
1.00 0.93 0.78
16 (406)
0.86
0.80 0.75 0.68
1.00
0.99 0.84
18 (457)
0.90
0.84 0.78 0.70
1.00 0.89
24 (610)
1.00
0.95 0.87 0.76
1.00
30 (762)
1.00 0.96 0.83
36 (914)
1.00 0.89
> 48 (1219)
1.00
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, fAV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
120 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
2-1/2 (64)
3
(76)
4
(102)
5
(127)
5-3/4 (146)
6
(152)
7
(178)
7-1/4 (184)
8
(203)
9
(229)
10 (254)
11-1/4 (286)
12 (305)
14 (356)
16 (406)
18 (457)
20 (508)
22 (559)
24 (610)
30 (762)
36 (914)
> 48 (1219)
Spacing factor
in tension
AN
2-3/4
(70)
n/a
0.58
0.60
0.63
0.67
0.69
0.70
0.73
0.74
0.77
0.80
0.83
0.88
0.90
0.97
1.00
4-1/2
(114)
n/a
0.58
0.60
0.63
0.67
0.69
0.70
0.73
0.74
0.77
0.80
0.83
0.88
0.90
0.97
1.00
6
(152)
n/a
0.57
0.58
0.61
0.64
0.66
0.67
0.69
0.70
0.72
0.75
0.78
0.81
0.83
0.89
0.94
1.00
10
(254)
n/a
0.54
0.55
0.57
0.58
0.60
0.60
0.62
0.62
0.63
0.65
0.67
0.69
0.70
0.73
0.77
0.80
0.83
0.87
0.90
1.00
4-1/2
(114)
0.25
0.28
0.30
0.35
0.40
0.45
0.46
0.52
0.54
0.60
0.67
0.75
0.84
0.90
1.00
6
(152)
0.19
0.22
0.24
0.27
0.31
0.34
0.35
0.39
0.40
0.44
0.49
0.55
0.62
0.66
0.77
0.88
0.99
1.00
10
(254)
0.11
0.13
0.14
0.16
0.18
0.20
0.20
0.23
0.23
0.26
0.29
0.32
0.36
0.38
0.45
0.51
0.58
0.64
0.70
0.77
0.96
1.00
Spacing factor
in shear4
AV
2-3/4
(70)
n/a
0.55
0.56
0.58
0.60
0.62
0.63
0.65
0.65
0.67
0.69
0.71
0.74
0.75
0.79
0.83
0.88
0.92
0.96
1.00
4-1/2
(114)
n/a
0.53
0.54
0.55
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.72
0.74
0.77
0.80
0.82
0.90
0.98
1.00
6
(152)
n/a
0.53
0.53
0.54
0.55
0.56
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.68
0.70
0.72
0.74
0.80
0.86
0.98
10
(254)
n/a
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.69
0.73
0.81
To edge
RV
Toward edge
RV
2-3/4
(70)
0.10
0.18
0.23
0.36
0.50
0.61
0.65
0.82
0.87
1.00
4-1/2
(114)
0.05
0.09
0.12
0.18
0.26
0.32
0.34
0.42
0.45
0.52
0.62
0.72
0.86
0.95
1.00
6
(152)
0.03
0.06
0.08
0.12
0.17
0.21
0.22
0.28
0.29
0.34
0.40
0.47
0.56
0.62
0.78
0.95
1.00
10
(254)
0.02
0.03
0.04
0.06
0.08
0.10
0.11
0.14
0.15
0.17
0.20
0.24
0.28
0.31
0.39
0.48
0.57
0.67
0.77
0.88
1.00
2-3/4
(70)
0.21
0.35
0.44
0.54
0.67
0.77
0.80
0.94
0.97
1.00
4-1/2
(114)
0.11
0.18
0.24
0.35
0.40
0.45
0.46
0.52
0.54
0.60
0.67
0.75
0.84
0.90
1.00
6
(152)
0.07
0.12
0.15
0.24
0.33
0.36
0.37
0.41
0.42
0.45
0.49
0.55
0.62
0.66
0.77
0.88
0.99
1.00
Concrete thickness
factor in shear5
HV
10
(254)
0.03
0.06
0.08
0.12
0.17
0.21
0.22
0.28
0.29
0.32
0.34
0.36
0.39
0.41
0.46
0.51
0.58
0.64
0.70
0.77
0.96
1.00
2-3/4
(70)
n/a
n/a
n/a
0.58
0.65
0.69
0.71
0.77
0.78
0.82
0.87
0.92
0.97
1.00
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
0.56
0.57
0.61
0.62
0.66
0.70
0.73
0.78
0.80
0.87
0.93
0.98
1.00
6
(152)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.57
0.60
0.64
0.67
0.70
0.75
0.80
0.85
0.90
0.94
0.98
1.00
10
(254)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.55
0.60
0.64
0.68
0.71
0.75
0.78
0.87
0.96
1.00
Table 29 - Load adjustment factors for 1/2-in. diameter threaded rods in cracked concrete1,2,3
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
10 2-3/4 4-1/2 6
10 2-3/4 4-1/2 6
10 2-3/4 4-1/2 6
10 2-3/4 4-1/2 6
10 2-3/4 4-1/2 6
10
Embedment in. 2-3/4 4-1/2 6
hef
(mm) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254) (70) (114) (152) (254)
1-3/4 (44) n/a n/a n/a n/a 0.48 0.48 0.45 0.41 n/a n/a n/a n/a 0.10 0.06 0.04 0.03 0.21 0.11 0.09 0.05 n/a n/a n/a n/a
2-1/2 (64) 0.58 0.58 0.57 0.54 0.53 0.53 0.50 0.44 0.55 0.54 0.53 0.52 0.18 0.10 0.07 0.04 0.35 0.20 0.15 0.09 n/a n/a n/a n/a
3
(76) 0.60 0.60 0.58 0.55 0.57 0.57 0.53 0.46 0.56 0.54 0.53 0.52 0.23 0.13 0.10 0.06 0.47 0.26 0.19 0.12 n/a n/a n/a n/a
4
(102) 0.63 0.63 0.61 0.57 0.66 0.66 0.60 0.49 0.58 0.56 0.55 0.53 0.36 0.20 0.15 0.09 0.72 0.39 0.30 0.18 0.58 n/a n/a n/a
5
(127) 0.67 0.67 0.64 0.58 0.75 0.75 0.67 0.53 0.61 0.57 0.56 0.54 0.50 0.28 0.21 0.12 1.00 0.55 0.41 0.25 0.65 n/a n/a n/a
5-3/4 (146) 0.69 0.69 0.66 0.60 0.82 0.82 0.73 0.56 0.62 0.58 0.57 0.55 0.62 0.34 0.26 0.15
0.68 0.51 0.31 0.70 0.57 n/a n/a
6
(152) 0.70 0.70 0.67 0.60 0.85 0.85 0.75 0.57 0.63 0.58 0.57 0.55 0.66 0.36 0.27 0.16
0.73 0.54 0.33 0.71 0.58 n/a n/a
7
(178) 0.73 0.73 0.69 0.62 0.95 0.95 0.83 0.62 0.65 0.60 0.58 0.56 0.83 0.46 0.34 0.21
0.91 0.69 0.41 0.77 0.63 n/a n/a
7-1/4 (184) 0.74 0.74 0.70 0.62 0.98 0.98 0.85 0.63 0.65 0.60 0.58 0.56 0.88 0.48 0.36 0.22
0.96 0.72 0.43 0.78 0.64 0.58 n/a
8
(203) 0.77 0.77 0.72 0.63 1.00 1.00 0.91 0.66 0.67 0.61 0.59 0.57 1.00 0.56 0.42 0.25
1.00 0.84 0.50 0.82 0.67 0.61 n/a
9
(229) 0.80 0.80 0.75 0.65
1.00 0.70 0.69 0.63 0.60 0.57
0.67 0.50 0.30
1.00 0.60 0.87 0.71 0.65 n/a
10 (254) 0.83 0.83 0.78 0.67
0.75 0.71 0.64 0.62 0.58
0.78 0.59 0.35
0.70 0.92 0.75 0.68 n/a
11-1/4 (286) 0.88 0.88 0.81 0.69
0.81 0.74 0.66 0.63 0.59
0.93 0.70 0.42
0.81 0.97 0.80 0.72 0.61
12 (305) 0.90 0.90 0.83 0.70
0.85 0.75 0.67 0.64 0.60
1.00 0.77 0.46
0.85 1.00 0.82 0.75 0.63
14 (356) 0.97 0.97 0.89 0.73
0.95 0.79 0.70 0.66 0.62
0.97 0.58
0.95
0.89 0.81 0.68
16 (406) 1.00 1.00 0.94 0.77
1.00 0.84 0.73 0.69 0.63
1.00 0.71
1.00
0.95 0.86 0.73
18 (457)
1.00 0.80
0.88 0.75 0.71 0.65
0.85
1.00 0.92 0.77
20 (508)
0.83
0.92 0.78 0.73 0.67
0.99
0.97 0.81
22 (559)
0.87
0.96 0.81 0.76 0.68
1.00
1.00 0.85
24 (610)
0.90
1.00 0.84 0.78 0.70
0.89
30 (762)
1.00
0.92 0.85 0.75
1.00
36 (914)
1.00 0.92 0.80
> 48 (1219)
1. 1.00 0.90
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction actor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
3.2.5
3.2.4
3.2.5
3.2.3
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 121
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
3-1/8 (79)
4 (102)
4-5/8 (117)
5 (127)
6 (152)
7 (178)
7-1/8 (181)
8 (203)
9 (229)
10 (254)
11 (279)
12 (305)
14 (356)
16 (406)
18 (457)
20 (508)
22 (559)
24 (610)
26 (660)
28 (711)
30 (762)
36 (914)
>48 (1219)
Spacing factor
in tension
AN
3-1/8
(79)
n/a
0.59
0.61
0.63
0.64
0.66
0.69
0.69
0.72
0.75
0.77
0.80
0.83
0.88
0.94
0.99
1.00
5-5/8
(143)
n/a
0.59
0.61
0.63
0.64
0.66
0.69
0.69
0.72
0.75
0.77
0.80
0.83
0.88
0.94
0.99
1.00
7-1/2
(191)
n/a
0.57
0.59
0.60
0.61
0.63
0.66
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.86
0.90
0.94
0.99
1.00
12-1/2
(318)
n/a
0.54
0.55
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.79
0.82
0.85
0.87
0.90
0.98
1.00
5-5/8
(143)
0.23
0.28
0.32
0.34
0.36
0.40
0.44
0.45
0.49
0.54
0.61
0.67
0.73
0.85
0.97
1.00
7-1/2
(191)
0.18
0.22
0.24
0.26
0.27
0.30
0.33
0.34
0.37
0.40
0.44
0.49
0.53
0.62
0.71
0.80
0.89
0.98
1.00
12-1/2
(318)
0.11
0.13
0.14
0.15
0.16
0.18
0.20
0.20
0.21
0.23
0.26
0.29
0.31
0.36
0.42
0.47
0.52
0.57
0.62
0.68
0.73
0.78
0.94
1.00
Spacing factor
in shear4
AV
3-1/8
(79)
n/a
0.56
0.58
0.59
0.60
0.62
0.64
0.64
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.85
0.89
0.93
0.97
1.00
5-5/8
(143)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.64
0.66
0.69
0.71
0.73
0.75
0.78
0.80
0.82
0.85
0.92
1.00
7-1/2
(191)
n/a
0.53
0.53
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.62
0.64
0.66
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
12-1/2
(318)
n/a
0.52
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.62
0.63
0.64
0.65
0.66
0.69
0.75
To edge
RV
Toward edge
RV
3-1/8
(79)
0.09
0.22
0.32
0.40
0.45
0.59
0.75
0.77
0.91
1.00
5-5/8
(143)
0.04
0.10
0.15
0.18
0.21
0.27
0.34
0.35
0.41
0.50
0.58
0.67
0.76
0.96
1.00
7-1/2
(191)
0.03
0.07
0.10
0.12
0.13
0.18
0.22
0.23
0.27
0.32
0.38
0.43
0.50
0.62
0.76
0.91
1.00
12-1/2
(318)
0.01
0.03
0.04
0.06
0.06
0.08
0.10
0.11
0.13
0.15
0.18
0.20
0.23
0.29
0.36
0.43
0.50
0.58
0.66
0.74
0.83
0.92
1.00
3-1/8
(79)
0.19
0.44
0.52
0.59
0.63
0.76
0.88
0.90
1.00
5-5/8
(143)
0.08
0.20
0.29
0.34
0.36
0.40
0.44
0.45
0.49
0.54
0.61
0.67
0.73
0.85
0.97
1.00
7-1/2
(191)
0.06
0.13
0.19
0.24
0.27
0.33
0.36
0.36
0.39
0.42
0.46
0.49
0.53
0.62
0.71
0.80
0.89
0.98
1.00
Concrete thickness
factor in shear5
HV
12-1/2
(318)
0.03
0.06
0.09
0.11
0.12
0.16
0.21
0.21
0.25
0.30
0.32
0.34
0.36
0.39
0.43
0.47
0.52
0.57
0.62
0.68
0.73
0.78
0.94
1.00
3-1/8
(79)
n/a
n/a
n/a
0.60
0.63
0.69
0.74
0.75
0.79
0.84
0.89
0.93
0.97
1.00
5-5/8
(143)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.61
0.65
0.68
0.71
0.75
0.81
0.86
0.91
0.96
1.00
7-1/2
(191)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.59
0.62
0.65
0.70
0.75
0.79
0.83
0.87
0.91
0.95
0.99
1.00
12-1/2
(318)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.58
0.61
0.65
0.68
0.71
0.74
0.77
0.79
0.87
Table 31 - Load adjustment factors for 5/8-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
5/8-in.
cracked
concrete
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in. 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2 3-1/8 5-5/8 7-1/2 12-1/2
hef
(mm) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318) (79) (143) (191) (318)
1-3/4 (44) n/a n/a n/a n/a 0.45 0.45 0.43 0.40 n/a n/a n/a n/a 0.09 0.04 0.03 0.02 0.19 0.09 0.06 0.04 n/a n/a n/a n/a
3-1/8 (79) 0.59 0.59 0.57 0.54 0.54 0.54 0.50 0.44 0.56 0.54 0.53 0.52 0.22 0.10 0.08 0.05 0.45 0.20 0.15 0.09 n/a n/a n/a n/a
4 (102) 0.61 0.61 0.59 0.55 0.60 0.60 0.55 0.46 0.58 0.55 0.54 0.53 0.33 0.15 0.11 0.07 0.65 0.30 0.22 0.13 n/a n/a n/a n/a
4-5/8 (117) 0.63 0.63 0.60 0.56 0.64 0.64 0.58 0.48 0.59 0.55 0.54 0.53 0.40 0.18 0.14 0.08 0.81 0.37 0.27 0.16 0.60 n/a n/a n/a
5 (127) 0.64 0.64 0.61 0.57 0.67 0.67 0.60 0.49 0.60 0.56 0.55 0.53 0.45 0.21 0.15 0.09 0.91 0.41 0.30 0.18 0.63 n/a n/a n/a
6 (152) 0.66 0.66 0.63 0.58 0.74 0.74 0.66 0.53 0.62 0.57 0.56 0.54 0.60 0.27 0.20 0.12 1.00 0.54 0.40 0.24 0.69 n/a n/a n/a
7 (178) 0.69 0.69 0.66 0.59 0.82 0.82 0.72 0.56 0.64 0.58 0.57 0.55 0.75 0.34 0.25 0.15
0.68 0.50 0.30 0.74 n/a n/a n/a
7-1/8 (181) 0.69 0.69 0.66 0.60 0.83 0.83 0.73 0.56 0.64 0.58 0.57 0.55 0.77 0.35 0.26 0.16
0.70 0.52 0.31 0.75 0.58 n/a n/a
8 (203) 0.72 0.72 0.68 0.61 0.90 0.90 0.78 0.59 0.66 0.59 0.58 0.55 0.92 0.42 0.31 0.19
0.84 0.62 0.37 0.79 0.61 n/a n/a
9 (229) 0.75 0.75 0.70 0.62 0.99 0.99 0.85 0.62 0.68 0.60 0.59 0.56 1.00 0.50 0.37 0.22
1.00 0.74 0.44 0.84 0.65 0.59 n/a
10 (254) 0.77 0.77 0.72 0.63 1.00 1.00 0.91 0.66 0.70 0.62 0.60 0.57
0.58 0.43 0.26
0.86 0.52 0.89 0.68 0.62 n/a
11 (279) 0.80 0.80 0.74 0.65
0.98 0.69 0.72 0.63 0.60 0.57
0.67 0.50 0.30
0.98 0.60 0.93 0.72 0.65 n/a
12 (305) 0.83 0.83 0.77 0.66
1.00 0.73 0.74 0.64 0.61 0.58
0.77 0.57 0.34
1.00 0.68 0.97 0.75 0.68 n/a
14 (356) 0.88 0.88 0.81 0.69
0.81 0.78 0.66 0.63 0.59
0.97 0.71 0.43
0.81 1.00 0.81 0.73 0.62
16 (406) 0.94 0.94 0.86 0.71
0.89 0.82 0.69 0.65 0.61
1.00 0.87 0.52
0.89
0.86 0.78 0.66
18 (457) 0.99 0.99 0.90 0.74
0.97 0.85 0.71 0.67 0.62
1.00 0.62
0.97
0.92 0.83 0.70
20 (508) 1.00 1.00 0.94 0.77
1.00 0.89 0.73 0.69 0.64
0.73
1.00
0.97 0.87 0.74
22 (559)
0.99 0.79
0.93 0.76 0.71 0.65
0.84
1.00 0.91 0.77
24 (610)
1.00 0.82
0.97 0.78 0.73 0.66
0.96
0.96 0.81
26 (660)
0.85
1.00 0.80 0.75 0.68
1.00
0.99 0.84
28 (711)
0.87
0.83 0.77 0.69
1.00 0.87
30 (762)
0.90
0.85 0.79 0.70
0.90
36 (914)
0.98
0.92 0.84 0.74
0.99
>48 (1219)
1.00
1.00 0.96 0.82
1.00
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
122 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
3-3/4 (95)
4
(102)
5
(127)
5-1/4 (133)
6
(152)
7
(178)
8
(203)
8-1/2 (216)
9
(229)
10 (254)
10-3/4 (273)
12 (305)
14 (356)
16 (406)
16-3/4 (425)
18 (457)
20 (508)
22 (559)
24 (610)
26 (660)
28 (711)
30 (762)
36 (914)
> 48 (1219)
Spacing factor
in tension
AN
3-1/2
(89)
n/a
0.59
0.59
0.62
0.62
0.64
0.66
0.69
0.70
0.71
0.73
0.75
0.78
0.82
0.87
0.89
0.92
0.96
1.00
6-3/4
(171)
n/a
0.59
0.59
0.62
0.62
0.64
0.66
0.69
0.70
0.71
0.73
0.75
0.78
0.82
0.87
0.89
0.92
0.96
1.00
9
(229)
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.69
0.70
0.72
0.76
0.80
0.81
0.83
0.87
0.91
0.94
0.98
1.00
15
(381)
n/a
0.54
0.54
0.56
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.66
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
1.00
6-3/4
(171)
0.23
0.29
0.30
0.33
0.34
0.36
0.40
0.43
0.45
0.47
0.51
0.55
0.61
0.71
0.82
0.85
0.92
1.00
9
(229)
0.18
0.22
0.22
0.25
0.25
0.27
0.30
0.32
0.34
0.35
0.38
0.40
0.45
0.53
0.60
0.63
0.68
0.75
0.83
0.90
0.98
1.00
15
(381)
0.10
0.13
0.13
0.15
0.15
0.16
0.17
0.19
0.20
0.21
0.22
0.24
0.26
0.31
0.35
0.37
0.40
0.44
0.48
0.53
0.57
0.62
0.66
1.00
Spacing factor
in shear4
AV
3-1/2
(89)
n/a
0.57
0.57
0.59
0.60
0.61
0.63
0.65
0.66
0.67
0.68
0.70
0.72
0.76
0.79
0.81
0.83
0.87
0.91
0.94
0.98
1.00
6-3/4
(171)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.70
0.72
0.74
0.76
0.78
0.80
0.86
0.99
9
(229)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.61
0.62
0.63
0.64
0.65
0.67
0.68
0.70
0.71
0.73
0.77
0.86
15
(381)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.72
To edge
RV
Toward edge
RV
3-1/2
(89)
0.09
0.27
0.29
0.41
0.44
0.54
0.68
0.83
0.91
0.99
1.00
6-3/4
(171)
0.03
0.11
0.12
0.17
0.18
0.22
0.28
0.34
0.37
0.40
0.47
0.53
0.62
0.78
0.96
1.00
9
(229)
0.02
0.07
0.08
0.11
0.12
0.14
0.18
0.22
0.24
0.26
0.31
0.34
0.40
0.51
0.62
0.67
0.74
0.87
1.00
15
(381)
0.01
0.03
0.04
0.05
0.05
0.07
0.08
0.10
0.11
0.12
0.14
0.16
0.19
0.24
0.29
0.31
0.35
0.40
0.47
0.53
0.60
0.67
0.74
1.00
3-1/2
(89)
0.17
0.49
0.51
0.60
0.63
0.72
0.84
0.96
1.00
6-3/4
(171)
0.07
0.22
0.24
0.33
0.34
0.36
0.40
0.43
0.45
0.47
0.51
0.55
0.61
0.71
0.82
0.85
0.92
1.00
9
(229)
0.05
0.14
0.16
0.22
0.23
0.29
0.33
0.35
0.37
0.38
0.41
0.43
0.46
0.53
0.60
0.63
0.68
0.75
0.83
0.90
0.98
1.00
Concrete thickness
factor in shear5
HV
15
(381)
0.02
0.07
0.07
0.10
0.11
0.13
0.17
0.20
0.22
0.24
0.29
0.31
0.33
0.36
0.39
0.40
0.42
0.45
0.49
0.53
0.57
0.62
0.66
1.00
3-1/2
(89)
n/a
n/a
n/a
n/a
0.62
0.66
0.72
0.77
0.79
0.81
0.86
0.89
0.94
1.00
6-3/4
(171)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.60
0.64
0.66
0.70
0.75
0.80
0.82
0.85
0.90
0.94
0.99
1.00
9
(229)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.65
0.70
0.71
0.74
0.78
0.82
0.85
0.89
0.92
0.95
1.00
15
(381)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.60
0.63
0.66
0.69
0.71
0.74
0.81
0.94
Table 33 - Load adjustment factors for 3/4-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
3/4-in.
cracked
concrete
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
15 3-1/2 6-3/4 9
15 3-1/2 6-3/4 9
15 3-1/2 6-3/4 9
15 3-1/2 6-3/4 9
15 3-1/2 6-3/4 9
15
Embedment in. 3-1/2 6-3/4 9
hef
(mm) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381) (89) (171) (229) (381)
1-3/4 (44) n/a n/a n/a n/a 0.44 0.44 0.42 0.39 n/a n/a n/a n/a 0.09 0.03 0.02 0.01 0.17 0.07 0.05 0.03 n/a n/a n/a n/a
3-3/4 (95) 0.59 0.59 0.57 0.54 0.54 0.54 0.50 0.44 0.57 0.54 0.53 0.52 0.27 0.11 0.08 0.05 0.54 0.22 0.15 0.09 n/a n/a n/a n/a
4
(102) 0.59 0.59 0.57 0.54 0.56 0.56 0.51 0.44 0.57 0.54 0.53 0.52 0.30 0.12 0.08 0.05 0.59 0.24 0.17 0.10 n/a n/a n/a n/a
5
(127) 0.62 0.62 0.59 0.56 0.61 0.61 0.56 0.47 0.59 0.55 0.54 0.53 0.41 0.17 0.12 0.07 0.83 0.34 0.24 0.14 n/a n/a n/a n/a
5-1/4 (133) 0.62 0.62 0.60 0.56 0.63 0.63 0.57 0.47 0.60 0.55 0.54 0.53 0.45 0.18 0.13 0.08 0.89 0.36 0.26 0.15 0.62 n/a n/a n/a
6
(152) 0.64 0.64 0.61 0.57 0.67 0.67 0.60 0.49 0.61 0.56 0.55 0.53 0.54 0.22 0.16 0.09 1.00 0.44 0.31 0.19 0.67 n/a n/a n/a
7
(178) 0.66 0.66 0.63 0.58 0.74 0.74 0.65 0.52 0.63 0.57 0.56 0.54 0.69 0.28 0.20 0.12
0.56 0.39 0.24 0.72 n/a n/a n/a
8
(203) 0.69 0.69 0.65 0.59 0.80 0.80 0.70 0.55 0.65 0.58 0.56 0.55 0.84 0.34 0.24 0.14
0.68 0.48 0.29 0.77 n/a n/a n/a
8-1/2 (216) 0.70 0.70 0.66 0.59 0.84 0.84 0.72 0.56 0.66 0.59 0.57 0.55 0.92 0.37 0.26 0.16
0.75 0.53 0.32 0.79 0.59 n/a n/a
9
(229) 0.71 0.71 0.67 0.60 0.87 0.87 0.75 0.57 0.67 0.59 0.57 0.55 1.00 0.41 0.29 0.17
0.82 0.57 0.34 0.82 0.61 n/a n/a
10 (254) 0.73 0.73 0.69 0.61 0.94 0.94 0.80 0.60 0.69 0.60 0.58 0.56
0.48 0.34 0.20
0.95 0.67 0.40 0.86 0.64 n/a n/a
10-3/4 (273) 0.75 0.75 0.70 0.62 1.00 1.00 0.84 0.62 0.70 0.61 0.59 0.56
0.53 0.37 0.22
1.00 0.75 0.45 0.89 0.66 0.59 n/a
12 (305) 0.78 0.78 0.72 0.63
0.91 0.66 0.72 0.62 0.60 0.57
0.63 0.44 0.26
0.88 0.53 0.94 0.70 0.62 n/a
14 (356) 0.82 0.82 0.76 0.66
1.00 0.72 0.76 0.64 0.61 0.58
0.79 0.56 0.33
1.00 0.67 1.00 0.76 0.67 n/a
16 (406) 0.87 0.87 0.80 0.68
0.78 0.80 0.66 0.63 0.59
0.97 0.68 0.41
0.78
0.81 0.72 n/a
16-3/4 (425) 0.89 0.89 0.81 0.69
0.81 0.81 0.67 0.63 0.60
1.00 0.73 0.44
0.81
0.83 0.73 0.62
18 (457) 0.92 0.92 0.83 0.70
0.85 0.83 0.68 0.64 0.60
0.81 0.49
0.85
0.86 0.76 0.64
20 (508) 0.96 0.96 0.87 0.72
0.91 0.87 0.70 0.66 0.61
0.95 0.57
0.91
0.90 0.80 0.68
22 (559) 1.00 1.00 0.91 0.74
0.98 0.91 0.72 0.68 0.63
1.00 0.66
0.98
0.95 0.84 0.71
24 (610)
0.94 0.77
1.00 0.94 0.74 0.69 0.64
0.75
1.00
0.99 0.88 0.74
26 (660)
0.98 0.79
0.98 0.76 0.71 0.65
0.84
1.00 0.91 0.77
28 (711)
1.00 0.81
1.00 0.79 0.73 0.66
0.94
0.95 0.80
30 (762)
0.83
0.81 0.74 0.67
1.00
0.98 0.83
36 (914)
0.90
0.87 0.79 0.71
1.00 0.91
> 48 (1219)
1.00
0.99 0.89 0.77
1.00
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 123
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
4-3/8 (111)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
9-7/8 (251)
10 (254)
11 (279)
12 (305)
12-1/2 (318)
14 (356)
16 (406)
18 (457)
19-1/2 (495)
20 (508)
22 (559)
24 (610)
26 (660)
28 (711)
30 (762)
36 (914)
> 48 (1219)
Spacing factor
in tension
AN
3-1/2
(89)
n/a
0.59
0.60
0.61
0.62
0.64
0.66
0.68
0.70
0.70
0.72
0.74
0.75
0.78
0.82
0.86
0.89
0.90
0.94
0.98
1.00
7-7/8
(200)
n/a
0.59
0.60
0.61
0.62
0.64
0.66
0.68
0.70
0.70
0.72
0.74
0.75
0.78
0.82
0.86
0.89
0.90
0.94
0.98
1.00
10-1/2
(267)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.66
0.66
0.67
0.69
0.70
0.72
0.75
0.79
0.81
0.82
0.85
0.88
0.91
0.94
0.98
1.00
17-1/2
(445)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.75
0.77
0.79
0.84
0.96
7-7/8
(200)
0.22
0.29
0.31
0.32
0.34
0.37
0.40
0.43
0.46
0.46
0.49
0.53
0.55
0.62
0.71
0.80
0.86
0.89
0.97
1.00
10-1/2
(267)
0.17
0.22
0.23
0.24
0.25
0.27
0.30
0.32
0.34
0.34
0.37
0.39
0.41
0.46
0.52
0.59
0.63
0.65
0.72
0.78
0.85
0.91
0.98
1.00
17-1/2
(445)
0.10
0.13
0.14
0.14
0.15
0.16
0.17
0.19
0.20
0.20
0.22
0.23
0.24
0.27
0.31
0.34
0.37
0.38
0.42
0.46
0.50
0.53
0.57
0.69
0.92
Spacing factor
in shear4
AV
3-1/2
(89)
n/a
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.69
0.69
0.71
0.73
0.74
0.77
0.80
0.84
0.87
0.88
0.92
0.96
0.99
1.00
7-7/8
(200)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.62
0.64
0.66
0.67
0.67
0.69
0.71
0.73
0.74
0.76
0.81
0.92
10-1/2
(267)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.63
0.64
0.66
0.67
0.68
0.70
0.73
0.81
17-1/2
(445)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.54
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.64
0.69
To edge
RV
Toward edge
RV
3-1/2
(89)
0.09
0.35
0.43
0.50
0.57
0.71
0.87
1.00
7-7/8
(200)
0.03
0.11
0.13
0.15
0.17
0.22
0.27
0.32
0.37
0.38
0.43
0.49
0.52
0.62
0.76
0.91
1.00
10-1/2
(267)
0.02
0.07
0.09
0.10
0.11
0.14
0.17
0.21
0.24
0.24
0.28
0.32
0.34
0.40
0.49
0.59
0.66
0.69
0.80
0.91
1.00
17-1/2
(445)
0.01
0.03
0.04
0.05
0.05
0.07
0.08
0.10
0.11
0.11
0.13
0.15
0.16
0.19
0.23
0.27
0.31
0.32
0.37
0.42
0.48
0.53
0.59
0.77
1.00
3-1/2
(89)
0.18
0.60
0.66
0.72
0.78
0.91
1.00
7-7/8
(200)
0.05
0.22
0.27
0.31
0.34
0.37
0.40
0.43
0.46
0.46
0.49
0.53
0.55
0.62
0.71
0.80
0.86
0.89
0.97
1.00
10-1/2
(267)
0.04
0.14
0.17
0.20
0.23
0.29
0.33
0.35
0.37
0.37
0.40
0.42
0.43
0.47
0.52
0.59
0.63
0.65
0.72
0.78
0.85
0.91
0.98
1.00
Concrete thickness
factor in shear5
HV
17-1/2
(445)
0.02
0.07
0.08
0.09
0.11
0.13
0.16
0.19
0.22
0.23
0.26
0.30
0.31
0.33
0.36
0.38
0.40
0.41
0.44
0.47
0.50
0.53
0.57
0.69
0.92
3-1/2
(89)
n/a
n/a
n/a
0.65
0.68
0.73
0.78
0.83
0.87
0.87
0.91
0.95
0.97
1.00
7-7/8
(200)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.59
0.62
0.65
0.66
0.70
0.75
0.79
0.82
0.83
0.87
0.91
0.95
0.99
1.00
10-1/2
(267)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.65
0.68
0.71
0.72
0.76
0.79
0.82
0.85
0.88
0.97
1.00
17-1/2
(445)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.56
0.59
0.61
0.64
0.66
0.68
0.75
0.87
Table 35 - Load adjustment factors for 7/8-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
7/8-in.
cracked
concrete
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in. 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2 3-1/2 7-7/8 10-1/2 17-1/2
hef
(mm) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445) (89) (200) (267) (445)
1-3/4 (44) n/a n/a n/a n/a 0.42 0.42 0.41 0.38 n/a n/a n/a n/a 0.09 0.03 0.02 0.01 0.18 0.06 0.04 0.02 n/a n/a n/a n/a
4-3/8 (111) 0.59 0.59 0.57 0.54 0.55 0.55 0.50 0.44 0.58 0.54 0.53 0.52 0.36 0.11 0.08 0.05 0.71 0.22 0.16 0.09 n/a n/a n/a n/a
5
(127) 0.60 0.60 0.58 0.55 0.58 0.58 0.52 0.45 0.60 0.54 0.53 0.52 0.43 0.13 0.09 0.06 0.87 0.27 0.19 0.11 n/a n/a n/a n/a
5-1/2 (140) 0.61 0.61 0.59 0.55 0.60 0.60 0.54 0.46 0.61 0.55 0.54 0.53 0.50 0.15 0.11 0.07 1.00 0.31 0.22 0.13 0.65 n/a n/a n/a
6
(152) 0.62 0.62 0.60 0.56 0.63 0.63 0.56 0.47 0.61 0.55 0.54 0.53 0.57 0.18 0.12 0.07
0.35 0.25 0.15 0.68 n/a n/a n/a
7
(178) 0.64 0.64 0.61 0.57 0.68 0.68 0.60 0.49 0.63 0.56 0.55 0.53 0.72 0.22 0.16 0.09
0.44 0.31 0.19 0.73 n/a n/a n/a
8
(203) 0.66 0.66 0.63 0.58 0.74 0.74 0.64 0.52 0.65 0.57 0.56 0.54 0.88 0.27 0.19 0.12
0.54 0.38 0.23 0.78 n/a n/a n/a
9
(229) 0.68 0.68 0.64 0.59 0.79 0.79 0.68 0.54 0.67 0.58 0.56 0.54 1.00 0.32 0.23 0.14
0.65 0.46 0.27 0.83 n/a n/a n/a
9-7/8 (251) 0.70 0.70 0.66 0.59 0.84 0.84 0.72 0.56 0.69 0.59 0.57 0.55
0.37 0.26 0.16
0.74 0.53 0.32 0.87 0.59 n/a n/a
10 (254) 0.70 0.70 0.66 0.60 0.85 0.85 0.73 0.56 0.69 0.59 0.57 0.55
0.38 0.27 0.16
0.76 0.54 0.32 0.87 0.59 n/a n/a
11 (279) 0.72 0.72 0.67 0.60 0.91 0.91 0.77 0.59 0.71 0.60 0.58 0.55
0.44 0.31 0.19
0.87 0.62 0.37 0.92 0.62 n/a n/a
12 (305) 0.74 0.74 0.69 0.61 0.98 0.98 0.82 0.61 0.73 0.60 0.58 0.56
0.50 0.35 0.21
1.00 0.70 0.42 0.96 0.65 n/a n/a
12-1/2 (318) 0.75 0.75 0.70 0.62 1.00 1.00 0.84 0.62 0.74 0.61 0.59 0.56
0.53 0.37 0.22
0.75 0.45 0.98 0.66 0.59 n/a
14 (356) 0.78 0.78 0.72 0.63
0.91 0.66 0.77 0.62 0.60 0.57
0.63 0.44 0.27
0.89 0.53 1.00 0.70 0.62 n/a
16 (406) 0.82 0.82 0.75 0.65
1.00 0.71 0.81 0.64 0.61 0.58
0.77 0.54 0.33
1.00 0.65
0.75 0.67 n/a
18 (457) 0.86 0.86 0.79 0.67
0.76 0.84 0.66 0.62 0.59
0.91 0.65 0.39
0.76
0.79 0.71 n/a
19-1/2 (495) 0.89 0.89 0.81 0.69
0.80 0.87 0.67 0.64 0.60
1.00 0.73 0.44
0.80
0.82 0.74 0.62
20 (508) 0.90 0.90 0.82 0.69
0.82 0.88 0.67 0.64 0.60
0.76 0.45
0.82
0.84 0.74 0.63
22 (559) 0.94 0.94 0.85 0.71
0.87 0.92 0.69 0.65 0.61
0.87 0.52
0.87
0.88 0.78 0.66
24 (610) 0.98 0.98 0.88 0.73
0.93 0.96 0.71 0.67 0.62
1.00 0.60
0.93
0.92 0.82 0.69
26 (660) 1.00 1.00 0.91 0.75
0.99 1.00 0.73 0.68 0.63
0.67
0.99
0.95 0.85 0.72
28 (711)
0.94 0.77
1.00
0.74 0.69 0.64
0.75
1.00
0.99 0.88 0.74
30 (762)
0.98 0.79
0.76 0.71 0.65
0.84
1.00 0.91 0.77
36 (914)
1.00 0.84
0.81 0.75 0.68
1.00
1.00 0.84
> 48 (1219)
0.96
0.92 0.83 0.74
0.97
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
124 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
5
(127)
6
(152)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10 (254)
11 (279)
11-1/4 (286)
12 (305)
13 (330)
14 (356)
14-1/4 (362)
16 (406)
18 (457)
20 (508)
22 (559)
22-1/4 (565)
24 (610)
26 (660)
28 (711)
30 (762)
36 (914)
> 48 (1219)
Spacing factor
in tension
AN
4
(102)
n/a
0.59
0.61
0.61
0.63
0.64
0.66
0.68
0.70
0.70
0.72
0.73
0.75
0.76
0.79
0.82
0.86
0.89
0.90
0.93
0.97
1.00
4
(229)
n/a
0.59
0.61
0.61
0.63
0.64
0.66
0.68
0.70
0.70
0.72
0.73
0.75
0.76
0.79
0.82
0.86
0.89
0.90
0.93
0.97
1.00
12
(305)
n/a
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.65
0.66
0.67
0.68
0.69
0.70
0.72
0.75
0.78
0.81
0.81
0.83
0.86
0.89
0.92
1.00
20
(508)
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.62
0.63
0.65
0.67
0.68
0.69
0.70
0.72
0.73
0.75
0.80
0.90
4
(229)
0.22
0.30
0.32
0.33
0.35
0.38
0.40
0.43
0.46
0.47
0.49
0.52
0.56
0.57
0.64
0.72
0.80
0.87
0.88
0.95
1.00
12
(305)
0.17
0.22
0.24
0.24
0.26
0.28
0.29
0.32
0.34
0.34
0.36
0.38
0.40
0.41
0.46
0.52
0.58
0.63
0.64
0.69
0.75
0.81
0.86
1.00
20
(508)
0.10
0.13
0.14
0.14
0.15
0.16
0.17
0.18
0.20
0.20
0.21
0.22
0.24
0.24
0.27
0.30
0.34
0.37
0.38
0.40
0.44
0.47
0.51
0.61
0.81
Spacing factor
in shear4
AV
4
(102)
n/a
0.59
0.60
0.61
0.62
0.64
0.65
0.67
0.69
0.69
0.70
0.72
0.74
0.74
0.77
0.81
0.84
0.88
0.88
0.91
0.94
0.98
1.00
4
(229)
n/a
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.61
0.62
0.64
0.65
0.67
0.67
0.68
0.70
0.71
0.73
0.77
0.86
12
(305)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.63
0.64
0.65
0.66
0.67
0.70
0.77
20
(508)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.58
0.59
0.60
0.60
0.62
0.66
To edge
RV
Toward edge
RV
4
(102)
0.08
0.37
0.48
0.51
0.61
0.74
0.89
1.00
4
(229)
0.02
0.11
0.14
0.15
0.18
0.22
0.26
0.31
0.35
0.37
0.40
0.46
0.51
0.52
0.62
0.74
0.87
1.00
12
(305)
0.01
0.07
0.09
0.10
0.12
0.14
0.17
0.20
0.23
0.24
0.26
0.30
0.33
0.34
0.40
0.48
0.56
0.65
0.66
0.74
0.84
0.94
1.00
20
(508)
0.01
0.03
0.04
0.05
0.05
0.07
0.08
0.09
0.11
0.11
0.12
0.14
0.15
0.16
0.19
0.22
0.26
0.30
0.31
0.35
0.39
0.43
0.48
0.63
0.98
4
(102)
0.15
0.61
0.70
0.73
0.82
0.93
1.00
4
(229)
0.05
0.22
0.29
0.30
0.35
0.38
0.40
0.43
0.46
0.47
0.49
0.52
0.56
0.57
0.64
0.72
0.80
0.87
0.88
0.95
1.00
12
(305)
0.03
0.14
0.19
0.20
0.23
0.29
0.33
0.35
0.37
0.37
0.39
0.41
0.43
0.43
0.47
0.52
0.58
0.63
0.64
0.69
0.75
0.81
0.86
1.00
Concrete thickness
factor in shear5
HV
20
(508)
0.01
0.07
0.09
0.09
0.11
0.13
0.16
0.19
0.21
0.22
0.24
0.28
0.31
0.31
0.33
0.36
0.38
0.40
0.41
0.43
0.45
0.48
0.51
0.61
0.81
4
(102)
n/a
n/a
n/a
0.65
0.69
0.74
0.78
0.83
0.87
0.88
0.91
0.94
0.98
0.99
1.00
4
(229)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.60
0.63
0.65
0.66
0.70
0.74
0.78
0.82
0.82
0.85
0.89
0.92
0.95
1.00
12
(305)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.64
0.67
0.71
0.71
0.74
0.77
0.80
0.83
0.91
1.00
20
(508)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.60
0.62
0.64
0.70
0.81
Table 37 - Load adjustment factors for 1-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
1-in.
cracked
concrete
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
4
4
12
20
4
4
12
20
4
4
12
20
4
4
12
20
4
4
12
20
4
4
12
20
Embedment in.
hef
(mm) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508) (102) (229) (305) (508)
1-3/4 (44) n/a n/a n/a n/a 0.42 0.42 0.40 0.38 n/a n/a n/a n/a 0.08 0.02 0.02 0.01 0.15 0.05 0.03 0.02 n/a n/a n/a n/a
5
(127) 0.59 0.59 0.57 0.54 0.55 0.55 0.50 0.44 0.59 0.54 0.53 0.52 0.37 0.11 0.08 0.05 0.74 0.22 0.16 0.09 n/a n/a n/a n/a
6
(152) 0.61 0.61 0.58 0.55 0.59 0.59 0.53 0.46 0.60 0.55 0.54 0.53 0.49 0.14 0.10 0.06 0.97 0.29 0.21 0.12 n/a n/a n/a n/a
6-1/4 (159) 0.61 0.61 0.59 0.55 0.60 0.60 0.54 0.46 0.61 0.55 0.54 0.53 0.52 0.15 0.11 0.07 1.00 0.31 0.22 0.13 0.66 n/a n/a n/a
7
(178) 0.63 0.63 0.60 0.56 0.64 0.64 0.57 0.47 0.62 0.55 0.54 0.53 0.61 0.18 0.13 0.08
0.36 0.26 0.16 0.69 n/a n/a n/a
8
(203) 0.64 0.64 0.61 0.57 0.69 0.69 0.60 0.49 0.64 0.56 0.55 0.53 0.75 0.22 0.16 0.10
0.44 0.32 0.19 0.74 n/a n/a n/a
9
(229) 0.66 0.66 0.63 0.58 0.74 0.74 0.64 0.51 0.65 0.57 0.56 0.54 0.89 0.26 0.19 0.11
0.53 0.38 0.23 0.79 n/a n/a n/a
10 (254) 0.68 0.68 0.64 0.58 0.79 0.79 0.67 0.53 0.67 0.58 0.56 0.54 1.00 0.31 0.22 0.13
0.62 0.44 0.27 0.83 n/a n/a n/a
11 (279) 0.70 0.70 0.65 0.59 0.84 0.84 0.71 0.55 0.69 0.58 0.57 0.55
0.36 0.26 0.15
0.72 0.51 0.31 0.87 n/a n/a n/a
11-1/4 (286) 0.70 0.70 0.66 0.59 0.85 0.85 0.72 0.56 0.69 0.59 0.57 0.55
0.37 0.26 0.16
0.74 0.53 0.32 0.88 0.59 n/a n/a
12 (305) 0.72 0.72 0.67 0.60 0.89 0.89 0.75 0.57 0.71 0.59 0.57 0.55
0.41 0.29 0.18
0.82 0.58 0.35 0.91 0.61 n/a n/a
13 (330) 0.73 0.73 0.68 0.61 0.95 0.95 0.79 0.59 0.72 0.60 0.58 0.56
0.46 0.33 0.20
0.92 0.66 0.39 0.95 0.63 n/a n/a
14 (356) 0.75 0.75 0.69 0.62 1.00 1.00 0.83 0.62 0.74 0.61 0.59 0.56
0.51 0.37 0.22
1.00 0.74 0.44 0.98 0.65 n/a n/a
14-1/4 (362) 0.76 0.76 0.70 0.62
0.84 0.62 0.74 0.61 0.59 0.56
0.53 0.38 0.23
0.76 0.45 0.99 0.66 0.59 n/a
16 (406) 0.79 0.79 0.72 0.63
0.91 0.66 0.77 0.62 0.60 0.57
0.63 0.45 0.27
0.90 0.54 1.00 0.70 0.63 n/a
18 (457) 0.82 0.82 0.75 0.65
1.00 0.70 0.81 0.64 0.61 0.58
0.75 0.54 0.32
1.00 0.64
0.74 0.66 n/a
20 (508) 0.86 0.86 0.78 0.67
0.75 0.84 0.65 0.62 0.59
0.88 0.63 0.38
0.75
0.78 0.70 n/a
22 (559) 0.89 0.89 0.81 0.68
0.80 0.88 0.67 0.63 0.60
1.00 0.72 0.43
0.80
0.82 0.73 n/a
22-1/4 (565) 0.90 0.90 0.81 0.69
0.80 0.88 0.67 0.64 0.60
0.74 0.44
0.80
0.82 0.74 0.62
24 (610) 0.93 0.93 0.83 0.70
0.85 0.91 0.68 0.65 0.60
0.83 0.50
0.85
0.86 0.77 0.65
26 (660) 0.97 0.97 0.86 0.72
0.90 0.95 0.70 0.66 0.61
0.93 0.56
0.90
0.89 0.80 0.67
28 (711) 1.00 1.00 0.89 0.73
0.95 0.98 0.71 0.67 0.62
1.00 0.62
0.95
0.92 0.83 0.70
30 (762)
0.92 0.75
1.00 1.00 0.73 0.68 0.63
0.69
1.00
0.96 0.86 0.72
36 (914)
1.00 0.80
0.77 0.72 0.66
0.91
1.00 0.94 0.79
> 48 (1219)
0.90
0.87 0.79 0.71
1.00
1.00 0.91
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 125
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
1-3/4 (44)
6-1/4 (159)
7
(178)
8
(203)
9
(229)
10 (254)
11 (279)
12 (305)
13 (330)
14 (356)
14-1/4 (362)
15 (381)
16 (406)
17 (432)
18 (457)
20 (508)
22 (559)
24 (610)
26 (660)
28 (711)
30 (762)
36 (914)
> 48 (1219)
Spacing factor
in tension
AN
5
(127)
n/a
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.69
0.71
0.71
0.72
0.73
0.75
0.76
0.79
0.82
0.85
0.88
0.91
0.94
1.00
11-1/4
(286)
n/a
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.69
0.71
0.71
0.72
0.73
0.75
0.76
0.79
0.82
0.85
0.88
0.91
0.94
1.00
15
(381)
n/a
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.66
0.67
0.68
0.69
0.70
0.72
0.74
0.77
0.79
0.81
0.83
0.90
1.00
25
(635)
n/a
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.59
0.60
0.60
0.61
0.61
0.62
0.63
0.65
0.66
0.67
0.69
0.70
0.74
0.82
11-1/4
(286)
0.23
0.31
0.33
0.35
0.37
0.39
0.41
0.44
0.46
0.49
0.49
0.51
0.54
0.56
0.60
0.66
0.73
0.80
0.86
0.93
1.00
15
(381)
0.16
0.22
0.23
0.25
0.26
0.28
0.29
0.31
0.33
0.34
0.35
0.36
0.38
0.40
0.42
0.47
0.51
0.56
0.61
0.65
0.70
0.84
1.00
25
(635)
0.09
0.13
0.14
0.14
0.15
0.16
0.17
0.18
0.19
0.20
0.20
0.21
0.22
0.23
0.25
0.27
0.30
0.33
0.36
0.38
0.41
0.49
0.66
Spacing factor
in shear4
AV
5
(127)
n/a
0.59
0.60
0.61
0.62
0.64
0.65
0.66
0.68
0.69
0.69
0.70
0.72
0.73
0.75
0.77
0.80
0.83
0.86
0.88
0.91
0.99
1.00
11-1/4
(286)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.59
0.59
0.60
0.60
0.61
0.62
0.63
0.65
0.66
0.67
0.68
0.72
0.79
15
(381)
n/a
0.53
0.53
0.54
0.54
0.55
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.64
0.66
0.72
25
(635)
n/a
0.52
0.52
0.52
0.52
0.53
0.53
0.53
0.54
0.54
0.54
0.54
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.58
0.60
0.63
To edge
RV
Toward edge
RV
5
(127)
0.05
0.37
0.43
0.53
0.63
0.74
0.86
0.98
1.00
11-1/4
(286)
0.02
0.11
0.13
0.16
0.19
0.22
0.25
0.29
0.33
0.36
0.37
0.40
0.45
0.49
0.53
0.62
0.72
0.82
0.92
1.00
15
(381)
0.01
0.07
0.08
0.10
0.12
0.14
0.16
0.19
0.21
0.24
0.24
0.26
0.29
0.32
0.35
0.40
0.47
0.53
0.60
0.67
0.74
0.98
1.00
25
(635)
0.00
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.10
0.11
0.11
0.12
0.13
0.15
0.16
0.19
0.22
0.25
0.28
0.31
0.35
0.45
0.70
5
(127)
0.11
0.63
0.69
0.78
0.87
0.97
1.00
11-1/4
(286)
0.03
0.22
0.26
0.31
0.37
0.39
0.41
0.44
0.46
0.49
0.49
0.51
0.54
0.56
0.60
0.66
0.73
0.80
0.86
0.93
1.00
15
(381)
0.02
0.14
0.17
0.20
0.24
0.29
0.33
0.35
0.36
0.38
0.38
0.39
0.41
0.43
0.45
0.48
0.52
0.56
0.61
0.65
0.70
0.84
1.00
Concrete thickness
factor in shear5
HV
25
(635)
0.01
0.07
0.08
0.10
0.11
0.13
0.15
0.17
0.20
0.22
0.23
0.24
0.27
0.29
0.32
0.34
0.36
0.38
0.40
0.42
0.44
0.50
0.66
5
(127)
n/a
n/a
n/a
0.66
0.70
0.74
0.78
0.81
0.84
0.87
0.88
0.91
0.94
0.96
0.99
1.00
11-1/4
(286)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.59
0.60
0.62
0.64
0.66
0.70
0.73
0.76
0.79
0.82
0.85
0.94
1.00
15
(381)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.60
0.63
0.66
0.69
0.71
0.74
0.81
0.94
25
(635)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.57
0.63
0.72
Table 39 - Load adjustment factors for 1-1/4-in. diameter threaded rods in cracked concrete1,2,3
Edge distance in shear
1-1/4-in.
cracked
concrete
Spacing factor
in tension
AN
Spacing factor
in shear4
AV
Toward edge
RV
To edge
RV
Concrete thickness
factor in shear5
HV
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
5 11-1/4 15
25
5 11-1/4 15
25
5 11-1/4 15
25
5 11-1/4 15
25
5 11-1/4 15
25
5 11-1/4 15
25
Embedment in.
hef
(mm) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635) (127) (286) (381) (635)
1-3/4 (44) n/a n/a n/a n/a 0.40 0.40 0.39 0.37 n/a n/a n/a n/a 0.05 0.02 0.01 0.01 0.11 0.03 0.02 0.01 n/a n/a n/a n/a
6-1/4 (159) 0.59 0.59 0.57 0.54 0.55 0.55 0.50 0.44 0.59 0.54 0.53 0.52 0.37 0.11 0.08 0.05 0.74 0.22 0.16 0.10 n/a n/a n/a n/a
7
(178) 0.60 0.60 0.58 0.55 0.58 0.58 0.52 0.45 0.60 0.54 0.54 0.53 0.44 0.13 0.10 0.06 0.88 0.26 0.19 0.12 n/a n/a n/a n/a
8
(203) 0.62 0.62 0.59 0.55 0.62 0.62 0.55 0.46 0.61 0.55 0.54 0.53 0.54 0.16 0.12 0.07 1.00 0.32 0.24 0.14 0.66 n/a n/a n/a
9
(229) 0.63 0.63 0.60 0.56 0.66 0.66 0.57 0.48 0.62 0.55 0.55 0.53 0.64 0.19 0.14 0.08
0.38 0.28 0.17 0.70 n/a n/a n/a
10 (254) 0.65 0.65 0.61 0.57 0.69 0.69 0.60 0.49 0.64 0.56 0.55 0.54 0.75 0.22 0.17 0.10
0.44 0.33 0.20 0.74 n/a n/a n/a
11 (279) 0.66 0.66 0.62 0.57 0.74 0.74 0.63 0.51 0.65 0.57 0.56 0.54 0.86 0.26 0.19 0.11
0.51 0.38 0.23 0.78 n/a n/a n/a
12 (305) 0.68 0.68 0.63 0.58 0.78 0.78 0.66 0.53 0.66 0.57 0.56 0.54 0.98 0.29 0.22 0.13
0.58 0.44 0.26 0.81 n/a n/a n/a
13 (330) 0.69 0.69 0.64 0.59 0.82 0.82 0.69 0.54 0.68 0.58 0.57 0.55 1.00 0.33 0.25 0.15
0.66 0.49 0.29 0.85 n/a n/a n/a
14 (356) 0.71 0.71 0.66 0.59 0.86 0.86 0.72 0.56 0.69 0.59 0.57 0.55
0.37 0.27 0.16
0.73 0.55 0.33 0.88 0.58 n/a n/a
14-1/4 (362) 0.71 0.71 0.66 0.60 0.87 0.87 0.73 0.56 0.70 0.59 0.57 0.55
0.38 0.28 0.17
0.75 0.56 0.34 0.89 0.59 n/a n/a
15 (381) 0.72 0.72 0.67 0.60 0.91 0.91 0.75 0.57 0.71 0.59 0.58 0.55
0.41 0.30 0.18
0.82 0.61 0.36 0.91 0.61 n/a n/a
16 (406) 0.73 0.73 0.68 0.61 0.95 0.95 0.78 0.59 0.72 0.60 0.58 0.56
0.45 0.33 0.20
0.90 0.67 0.40 0.94 0.63 n/a n/a
17 (432) 0.75 0.75 0.69 0.61 1.00 1.00 0.81 0.61 0.73 0.60 0.59 0.56
0.49 0.37 0.22
0.98 0.73 0.44 0.97 0.64 n/a n/a
18 (457) 0.76 0.76 0.70 0.62
0.85 0.62 0.75 0.61 0.59 0.56
0.54 0.40 0.24
1.00 0.80 0.48 0.99 0.66 0.60 n/a
20 (508) 0.79 0.79 0.72 0.63
0.91 0.66 0.77 0.62 0.60 0.57
0.63 0.47 0.28
0.91 0.56 1.00 0.70 0.63 n/a
22 (559) 0.82 0.82 0.74 0.65
0.98 0.69 0.80 0.63 0.61 0.58
0.72 0.54 0.32
0.98 0.65
0.73 0.66 n/a
24 (610) 0.85 0.85 0.77 0.66
1.00 0.73 0.83 0.65 0.62 0.59
0.82 0.62 0.37
1.00 0.73
0.77 0.69 n/a
26 (660) 0.88 0.88 0.79 0.67
0.77 0.86 0.66 0.63 0.59
0.93 0.69 0.42
0.77
0.80 0.72 n/a
28 (711) 0.91 0.91 0.81 0.69
0.81 0.88 0.67 0.64 0.60
1.00 0.78 0.47
0.81
0.83 0.75 0.63
30 (762) 0.94 0.94 0.83 0.70
0.85 0.91 0.68 0.65 0.61
0.86 0.52
0.85
0.86 0.78 0.65
36 (914) 1.00 1.00 0.90 0.74
0.97 0.99 0.72 0.68 0.63
1.00 0.68
0.97
0.94 0.85 0.72
> 48 (1219)
1.00 0.82
1.00 1.00 0.79 0.74 0.67
1.00
1.00
1.00 0.98 0.83
1 Linear interpolation not permitted
2 Shaded area with reduced edge distance is permitted provided the installation torque is reduced to 0.30 Tmax for 5d < s < 16-in. and to 0.5 Tmax for s > 16-in.
3 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with a thin concrete member) the design can become very conservative. To
optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using the design equations from ACI 318 Appendix D.
4 Spacing factor reduction in shear, AV, assumes an influence of a nearby edge. If no edge exists, then AV = AN.
5 Concrete thickness reduction factor in shear, HV, assumes an influence of a nearby edge. If no edge exists, then HV = 1.0.
126 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Symbol
hef
minimum
maximum
hs
Tinst
hmin
Units
Thread size
3/8-16 UNC 1/2-13 UNC 5/8-11 UNC 3/4-10 UNC
in.
0.65
0.81
1.00
1.09
in.
11/16
7/8
1-1/8
1-1/4
in.
4-3/8
6-3/4
8-1/8
(mm)
(110)
(125)
(170)
(205)
in.
3/8
1/2
5/8
3/4
in.
15/16
1-3/16
1-1/2
1-7/8
ft-lb
15
30
60
100
(Nm)
(20)
(40)
(81)
(136)
in.
5.9
6.7
9.1
10.6
(mm)
(150)
(170)
(230)
(270)
3.2.3
3.2.5
1/2-, 5/8- and 3/4-in. HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum
tensile strength of 66.7 ksi (460 MPa) and a minimum yield strength of 54.4 ksi (375 MPa).
3.2.6
HIS-RN is manufactured from X5CrNiMo 17122 K700 stainless steel conforming to DIN EN 10088-3 with a minimum tensile
strength of 101.5 ksi (700 MPa) and a minimum yield strength of 50.8 ksi (350 MPa).
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 127
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4-3/8
(111)
5
(127)
6-3/4
(171)
8-1/8
(206)
7,140
(31.8)
8,720
(38.8)
13,680
(60.9)
18,065
(80.4)
7,820
(34.8)
9,555
(42.5)
14,985
(66.7)
19,790
(88.0)
9,030
(40.2)
11,030
(49.1)
17,305
(77.0)
22,850
(101.6)
11,060
(49.2)
13,510
(60.1)
21,190
(94.3)
27,985
(124.5)
15,375
(68.4)
18,785
(83.6)
29,460
(131.0)
38,910
(173.1)
16,840
(74.9)
20,575
(91.5)
32,275
(143.6)
42,620
(189.6)
19,445
(86.5)
23,760
(105.7)
37,265
(165.8)
49,215
(218.9)
23,815
(105.9)
29,100
(129.4)
45,645
(203.0)
60,275
(268.1)
Table 42 - Hilti HIT-RE 500-SD adhesive design strength (factored resistance) with concrete / bond failure for Hilti HIS-N
and HIS-RN internally threaded inserts in cracked concrete1,2,3,4,5,6,7,8,9,10
Tension Nn or Nr
Thread
size
3/8-16
UNC
1/2-13
UNC
5/8-11
UNC
3/4-10
UNC
Shear Vn or Vr
Effective
embedment
in. (mm)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
c = 2500 psi
(17.2 Mpa)
lb (kN)
c = 3000 psi
(20.7 Mpa)
lb (kN)
c = 4000 psi
(27.6 Mpa)
lb (kN)
c = 6000 psi
(41.4 Mpa)
lb (kN)
4-3/8
(111)
5
(127)
6-3/4
(171)
8-1/8
(206)
5,055
(22.5)
6,175
(27.5)
9,690
(43.1)
12,320
(54.8)
5,540
(24.6)
6,765
(30.1)
9,855
(43.8)
12,320
(54.8)
6,040
(26.9)
7,815
(34.8)
9,855
(43.8)
12,320
(54.8)
6,400
(28.5)
8,370
(37.2)
10,445
(46.5)
13,060
(58.1)
10,890
(48.4)
13,305
(59.2)
20,870
(92.8)
27,560
(122.6)
11,930
(53.1)
14,575
(64.8)
22,860
(101.7)
30,190
(134.3)
13,010
(57.9)
16,830
(74.9)
25,085
(111.6)
31,355
(139.5)
13,790
(61.3)
18,030
(80.2)
26,590
(118.3)
33,240
(147.9)
1
2
3
4
128 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Shear4
Vsa
lb (kN)
Seismic
Shear5
Vsa
lb (kN)
Tensile3
Nsa
lb (kN)
Shear4
Vsa
lb (kN)
Seismic
Shear5
Vsa
lb (kN)
3/8-16
UNC
6,300
3,490
2,443
5,540
3,070
2,149
(28.0)
(15.5)
(10.9)
(24.6)
(13.7)
(9.6)
1/2-13
UNC
11,530
6,385
4,470
10,145
5,620
3,934
(51.3)
(28.4)
(19.9)
(45.1)
(25.0)
(17.5)
5/8-11
UNC
18,365
10,170
7,119
16,160
8,950
6,265
(81.7)
(45.2)
(31.7)
(71.9)
(39.8)
(27.9)
3/4-10
UNC
27,180
15,055
10,539
23,915
13,245
9,272
(120.9)
(67.0)
(46.9)
(106.4)
(58.9)
(41.2)
Thread
size
1
2
3
4
5
See Section 3.1.7.3 to convert design strength (factored resistance) value to ASD value.
Steel bolt / cap screw for Hilti HIS-N and HIS-RN inserts are considered brittle steel elements.
Tensile = Ase,N futa as noted in ACI 318 Appendix D
Shear = 0.60 Ase,N futa as noted in ACI 318 Appendix D.
Seismic shear values determined by multiplying Vsa x V,seis where V,seis = 0.7 for steel bolt.
See Section 3.1.7.4 for additional information on seismic applications.
3.2.3
3.2.5
3.2.4
3.2.5
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 129
Thread
size
in.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
3-1/4 (83)
4
(102)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
24
(610)
30
(762)
36
(914)
> 48 (1219)
1/2
4-3/8
(111)
0.59
0.61
0.63
0.65
0.66
0.68
0.71
0.74
0.76
0.79
0.82
0.87
0.92
0.97
1.00
1.00
1.00
1.00
(127)
n/a
0.59
0.61
0.62
0.63
0.65
0.67
0.69
0.72
0.74
0.76
0.80
0.85
0.89
1.00
1.00
1.00
1.00
5/8
3/8
(206)
n/a
n/a
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.68
0.70
0.73
0.77
0.80
0.90
1.00
1.00
1.00
(111)
0.34
0.38
0.44
0.47
0.50
0.57
0.66
0.74
0.82
0.90
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
0.38
0.43
0.46
0.48
0.54
0.61
0.69
0.76
0.84
0.91
1.00
1.00
1.00
1.00
1.00
1.00
1.00
5/8
3/4
Spacing factor
in shear4
AV
3/8
(206)
n/a
n/a
n/a
0.35
0.37
0.40
0.43
0.46
0.50
0.53
0.57
0.66
0.76
0.85
1.00
1.00
1.00
1.00
(111)
0.55
0.56
0.57
0.58
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.71
0.74
0.77
0.85
0.94
1.00
1.00
1/2
5
(127)
n/a
0.55
0.57
0.58
0.58
0.60
0.61
0.62
0.64
0.65
0.66
0.69
0.72
0.75
0.83
0.91
0.99
1.00
5/8
3/4
3/8
To edge
RV
Toward edge
RV
(206)
n/a
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.63
0.65
0.70
0.75
0.80
0.90
(111)
0.15
0.21
0.29
0.34
0.39
0.49
0.60
0.71
0.83
0.96
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
0.19
0.26
0.30
0.35
0.43
0.53
0.63
0.74
0.86
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
5/8
3/4
3/8
(206)
n/a
n/a
n/a
0.15
0.17
0.21
0.26
0.31
0.36
0.41
0.47
0.59
0.73
0.87
1.00
1.00
1.00
1.00
(111)
0.31
0.38
0.44
0.47
0.50
0.57
0.66
0.74
0.82
0.90
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
0.38
0.43
0.46
0.48
0.54
0.61
0.69
0.76
0.84
0.91
1.00
1.00
1.00
1.00
1.00
1.00
1.00
5/8
Concrete thickness
factor in shear5
HV
3/4
3/8
(206)
n/a
n/a
n/a
0.29
0.33
0.40
0.43
0.46
0.50
0.53
0.57
0.66
0.76
0.85
1.00
1.00
1.00
1.00
(111)
n/a
n/a
n/a
n/a
0.60
0.64
0.69
0.73
0.77
0.81
0.84
0.91
0.97
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
n/a
n/a
n/a
n/a
0.62
0.66
0.70
0.74
0.78
0.81
0.87
0.94
0.99
1.00
1.00
1.00
1.00
5/8
3/4
6-3/4 8-1/8
(171)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.64
0.67
0.70
0.75
0.80
0.85
0.99
1.00
1.00
1.00
(206)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.64
0.69
0.73
0.78
0.90
1.00
1.00
1.00
Table 45 - Load adjustment factors for Hilti HIS-N and HIS-RN internally threaded inserts in cracked concrete1,2.3
HIS-N and HIS-RN
all diameters
cracked
concrete
Thread
size
in.
Spacing (s) / Edge Distance (ca) / Concrete Thickness (h), - in. (mm)
Embedment in.
hef
(mm)
3-1/4 (83)
4
(102)
5
(127)
5-1/2 (140)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
24
(610)
30
(762)
36
(914)
> 48 (1219)
1/2
4-3/8
(111)
0.59
0.61
0.63
0.65
0.66
0.68
0.71
0.74
0.76
0.79
0.82
0.87
0.92
0.97
1.00
1.00
1.00
1.00
(127)
n/a
0.59
0.61
0.62
0.63
0.65
0.67
0.69
0.72
0.74
0.76
0.80
0.85
0.89
1.00
1.00
1.00
1.00
5/8
3/8
(206)
n/a
n/a
n/a
0.59
0.60
0.62
0.63
0.65
0.67
0.68
0.70
0.73
0.77
0.80
0.90
1.00
1.00
1.00
(111)
0.54
0.59
0.66
0.69
0.73
0.80
0.88
0.96
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
0.54
0.59
0.62
0.65
0.71
0.77
0.83
0.90
0.96
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
5/8
3/4
Spacing factor
in shear4
AV
3/8
(206)
n/a
n/a
n/a
0.55
0.57
0.61
0.66
0.70
0.75
0.80
0.84
0.94
1.00
1.00
1.00
1.00
1.00
1.00
(111)
0.55
0.56
0.57
0.58
0.59
0.60
0.62
0.63
0.65
0.66
0.68
0.71
0.74
0.77
0.86
0.95
1.00
1.00
1/2
5
(127)
n/a
0.55
0.57
0.58
0.58
0.60
0.61
0.62
0.64
0.65
0.66
0.69
0.72
0.75
0.83
0.91
0.99
1.00
5/8
3/4
3/8
To edge
RV
Toward edge
RV
(206)
n/a
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.62
0.64
0.65
0.70
0.75
0.80
0.91
(111)
0.16
0.21
0.30
0.34
0.39
0.49
0.60
0.72
0.84
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
0.19
0.26
0.31
0.35
0.44
0.54
0.64
0.75
0.86
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
5/8
3/4
3/8
(206)
n/a
n/a
n/a
0.15
0.17
0.21
0.26
0.31
0.36
0.42
0.48
0.60
0.73
0.87
1.00
1.00
1.00
1.00
(111)
0.31
0.42
0.59
0.69
0.78
0.98
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
0.38
0.53
0.61
0.70
0.88
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
5/8
Concrete thickness
factor in shear5
HV
3/4
3/8
(206)
n/a
n/a
n/a
0.29
0.34
0.42
0.52
0.62
0.72
0.83
0.95
1.00
1.00
1.00
1.00
1.00
1.00
1.00
(111)
n/a
n/a
n/a
n/a
0.60
0.64
0.69
0.73
0.77
0.81
0.84
0.91
0.97
1.00
1.00
1.00
1.00
1.00
1/2
5
(127)
n/a
n/a
n/a
n/a
n/a
0.62
0.66
0.70
0.74
0.78
0.81
0.88
0.94
0.99
1.00
1.00
1.00
1.00
5/8
3/4
6-3/4 8-1/8
(171)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.64
0.67
0.70
0.76
0.81
0.86
0.99
1.00
1.00
1.00
(206)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.64
0.69
0.74
0.78
0.90
1.00
1.00
1.00
130 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Nominal
bit
diameter
in.
Adhesive volume
required
per inch of
embedment in 3
1/4
5/16
0.055
3/8
7/16
0.095
1/2
9/16
0.133
5/8
3/4
0.261
3/4
7/8
0.326
7/8
0.391
1-1/8
0.478
1-1/4
1-3/8
0.626
Rebar
size
Nominal bit1
diameter
in.
Adhesive
volume
required
per Inch of
embedment
in 3
#3
1/2
0.110
#4
5/8
0.146
#5
3/4
0.176
#6
7/8
0.218
#7
0.252
#8
1-1/8
0.299
#9
1-3/8
0.601
#10
1-1/2
0.659
#11
1-3/4
1.037
3.2.3
3.2.5
Example:
5/8-in. diameter rod with an embedment
of 10 inches:
Chemical
Chemicals Tested
Alkaline
Acids
Solvents
Benzyl alcohol
Ethanol
Ethyl acetate
Methyl ethyl ketone (MEK)
Trichlorethylene
Xylene (mixture)
Chemicals
used on job
sites
Concrete plasticizer
Diesel oil
Oil
Petrol
Oil for form work (forming oil)
Salt water
de-mineralized water
salt spraying test
SO2
Environment/weather
Gel Time
Full Cure
41
50
59
68
86
104
5
10
15
20
30
40
2.5 h
2h
1.5 h
30 min
20 min
12 min
72 h
48 h
24 h
12 h
8h
4h
Environmental
chemicals
3.2.4
Resistant
Not
Resistant
3.2.5
+
+
+
+
+
+
+
+
+
+
+
+
+
+
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 131
Qty of foil
packs
Package contents
Includes (1) foil pack with (1) mixer and 3/8 filler tube per pack
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8
filler tube per pack
25
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8
filler tube per pack and (1) HDM 500 manual dispenser
25
Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8
filler tube per pack
20
Includes (2) master cartons containing (20) foil packs each with (1) mixer
and 3/8 filler tube per pack and (1) HDM 500 manual dispenser
40
Includes (4) jumbo foil packs with (1) mixer and 3/8 filler tube per pack
Includes (64) jumbo foil packs with (1) mixer and 3/8 filler tube per pack
and (1) P8000 pneumatic dispenser
64
1 For complete information about Hilti anchors, adhesive anchoring dispensers, drilled hole preparation and other adhesive anchoring accessories, see HIT-HY 200
Anchoring System, Section 3.2.3.5 Ordering Information.
Fastener Components
HDE 500
Battery
Dispenser
HIT REMixer
HIT-RE 500-SD
Refill Pack
HDM 500
Manual
Dispenser
HIT-RE 500-SD
Medium Cartridge
P3500
Dispenser
P8000D
Dispenser
132 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 133
Product Description
3.2.5.2
Material Specifications
3.2.5.3
Technical Data
3.2.5.4
Installation Instructions
3.2.5.5
Ordering Information
Listings/Approvals
NSF/ANSI Std 61
certification for use in potable water
Europan Technical Approval
ETA-04/0027
ETA-08/0105
Underwater Fastenings
Oversized Holes
Diamond Cored Holes
Meets requirements of
ASTM C881-90, Type IV, Grade 2
and 3, Class A, B, C except
gel times
Meets requirements of AASHTO
specification M235, Type IV, Grade
3, Class A, B, C except gel times
Mixing tube provides proper
mixing, eliminates measuring
errors and minimizes waste
Contains no styrene and virtually
odorless
May be installed in concrete with
temperatures ranging from 23F
to 104F (-5C to 40C) with no
degrading of bond strength.
Product features
134 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.2.3
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 135
12.4 MPa
12.4 MPa
82.7 MPa
1,800 psi
1,800 psi
12,000 psi
1,493 MPa
43.5 MPa
6,310 psi
2.0%
63C
146F
0.06%
0.004
6.6 x 1013 /m
1 Minimum values obtained as the result of tests at 23F, 40F and 60F.
Symbol
Units
do
hef,std
Installation torque
embedment hef,std
Tinst
Installation torque
embedment < hef,std
Tinst
hmin
1/2
5/8
3/4
7/8
1-1/4
in.
7/16
9/16
11/16
13/16
15/16
1-1/16
1-1/2
in.
3-1/2
4-1/4
6-5/8
7-1/2
8-1/4
12
(mm)
(90)
(110)
(125)
(170)
(190)
(210)
(305)
ft-lb
18
30
75
150
175
235
400
(Nm)
(24)
(41)
(102)
(203)
(237)
(319)
(540)
ft-lb
15
20
50
105
125
165
280
(Nm)
(20)
(27)
(68)
(142)
(169)
(224)
(375)
in.
hef+2
hef+2-1/4
hef+3
(mm)
hef+51
hef+57
hef+76
1 Hole may be drilled with rotary hammer drill or Hilti DD EC-1 Diamond Coring System.
3.2.3
Table 3 - HIS-N and HIS-RN installation specifications with HIT-RE 500 adhesive anchor system
Setting
information
Thread size
Symbol
Units
in.
0.65
0.81
1.00
1.09
do
in.
11/16
7/8
1-1/8
1-1/4
in.
4-3/8
6-5/8
8-1/4
(mm)
(110)
(125)
(170)
(210)
in.
3/8
1/2
5/8
3/4
1-7/8
hef,std
minimum
Bolt engagement
maximum
hs
Installation torque
Tinst
hmin
in.
15/16
1-3/16
1-1/2
ft-lb
18
30
75
150
(Nm)
(24)
(41)
(102)
(203)
in.
5.9
6.7
9.1
10.6
(mm)
(150)
(170)
(230)
(270)
3.2.4
3.2.4
3.2.4
3.2.5
1 Hole may be drilled with rotary hammer drill or Hilti DD EC-1 Diamond Coring System.
3.2.6
Table 4 - Rebar installation specifications with HIT-RE 500 adhesive anchor system
Setting
information
Drill bit diameter1,2
Symbol
Units
do
in.
Rebar size
No. 3
No. 4
No. 5
No. 6
No. 7
No. 8
No. 9
No. 10
No. 11
1/2
5/8
3/4
7/8
1-1/8
1-3/8
1-1/2
1-9/16
1 Rebar diameters may vary. Use the smallest diameter drill bit which will accomodate the rebar.
2 Hole may be drilled with rotary hammer drill or Hilti DD EC-1 Diamond Coring System.
3.2.7
3.2.8
( ) ( )
Nd
N rec
5/3
Vd
Vrec
5/3
1.0
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 137
3/8
1/2
5/8
3/4
7/8
1-1/4
Tensile
Effective
embedment
in. (mm)
1-3/4
(44)
3-3/8
(86)
4-1/2
(114)
2-1/4
(57)
4-1/2
(114)
6
(152)
2-7/8
(73)
5-5/8
(143)
7-1/2
(190)
3-3/8
(86)
6-3/4
(172)
9
(229)
4
(101)
7-7/8
(200)
10-1/2
(267)
4-1/2
(114)
9
(229)
12
(305)
5-5/8
(143)
11-1/4
(286)
15
(381)
HIT-RE 500
Ultimate bond/concrete capacity
Shear
Tensile
Shear
'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi
(13.8 MPa)
(27.6 MPa)
(13.8 MPa)
(27.6 MPa)
(13.8 MPa)
(27.6 MPa)
(13.8 MPa)
(27.6 MPa)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
645
(2.9)
2,190
(9.7)
2,420
(10.8)
1,130
(5.0)
4,045
(18.0)
4,775
(21.2)
1,690
(7.5)
6,560
(29.2)
7,320
(32.6)
2,310
(10.3)
8,670
(38.6)
10,385
(46.2)
3,005
(13.4)
12,495
(55.6)
14,705
(65.4)
3,945
(17.5)
13,845
(61.6)
17,935
(79.8)
5,760
(25.6)
24,610
(109.5)
34,130
(151.8)
1,095
(4.9)
2,585
(11.5)
2,585
(11.5)
1,965
(8.7)
5,275
(23.5)
5,380
(23.9)
3,045
(13.5)
7,355
(32.7)
7,515
(33.4)
4,515
(20.1)
10,755
(47.8)
12,995
(57.8)
5,665
(25.2)
15,875
(70.6)
16,185
(72.0)
8,440
(37.5)
17,365
(77.2)
17,935
(79.8)
12,815
(57.0)
31,620
(140.7)
35,270
(156.9)
1,510
(6.7)
3,155
(14.0)
4,855
(21.6)
2,510
(11.2)
5,610
(25.0)
8,635
(38.4)
5,245
(23.3)
8,760
(39.0)
13,615
(60.6)
7,335
(32.6)
12,615
(56.1)
19,430
(86.4)
7,795
(34.7)
17,175
(76.4)
26,440
(117.6)
10,035
(44.6)
22,435
(99.8)
34,535
(153.6)
14,760
(65.7)
35,050
(155.9)
53,960
(240.0)
2,135
(9.5)
4,460
(19.8)
6,860
(30.5)
3,550
(15.8)
7,935
(35.3)
12,210
(54.3)
7,420
(33.0)
12,395
(55.1)
19,080
(84.9)
10,370
(46.1)
17,840
(79.4)
27,470
(122.2)
11,020
(49.0)
24,290
(108.0)
37,390
(166.3)
14,190
(63.1)
31,720
(141.1)
48,830
(217.2)
20,870
(92.8)
49,570
(220.5)
76,300
(339.4)
2,580
(11.5)
8,760
(39.0)
9,685
(43.1)
4,530
(20.2)
16,185
(72.0)
19,095
(84.9)
6,770
(30.1)
26,240
(116.7)
29,290
(130.3)
9,250
(41.1)
34,685
(154.3)
41,535
(184.8)
12,030
(53.5)
49,975
(222.3)
58,820
(261.6)
15,790
(70.2)
55,380
(246.3)
71,740
(319.1)
23,045
(102.5)
9,8430
(437.8)
136,525
(607.3)
4,370
(19.4)
10,345
(46.0)
10,335
(46.0)
7,860
(35.0)
21,095
(93.8)
21,520
(95.7)
12,175
(54.2)
29,420
(130.9)
30,060
(133.7)
18,065
(80.4)
43,020
(191.4)
51,985
(231.2)
22,670
(100.8)
63,495
(282.4)
64,730
(287.9)
33,765
(150.2)
69,465
(309.0)
71,740
(319.1)
51,270
(228.1)
126,480
(562.6)
141,090
(627.6)
4,530
(20.2)
9,460
(42.1)
14,560
(64.8)
7,525
(33.5)
16,820
(74.8)
25,900
(115.2)
15,735
(70.0)
26,280
(116.9)
40,480
(180.1)
22,000
(97.9)
37,840
(168.3)
58,280
(259.2)
23,375
(104.0)
51,520
(229.2)
79,320
(352.8)
30,104
(133.9)
67,300
(299.4)
103,600
(460.8)
44,280
(197.0)
105,140
(467.7)
161,880
(720.1)
6,405
(28.4)
13,380
(59.5)
20,580
(91.5)
10,640
(47.3)
23,800
(105.9)
36,620
(162.9)
22,250
(99.0)
37,180
(165.4)
57,240
(254.6)
31,108
(138.4)
53,520
(238.1)
82,400
(366.5)
33,050
(147.0)
72,860
(324.1)
112,160
(498.9)
42,565
(189.3)
95,160
(423.3)
146,480
(651.6)
62,610
(278.5)
148,710
(661.5)
228,900
(1018.2)
1 Influence factors for spacing and/or edge distance are applied to allowable concrete/bond values above, and then compared to the steel
value. The lesser of the values is to be used for the design.
2 Average ultimate concrete shear capacity based on Strength Design Method for standard and deep embedment and based on testing
for shallow embedment.
3 All values based on holes drilled with carbide bit and installed per manufacturers instructions. Ultimate tensile concrete/bond loads
represent the average values obtained in testing.
4 For underwater applications with a maximum depth of 165 ft (50 m), reduce the tabulated concrete/bond values 30% to account for reduced
mechanical properties of saturated concrete.
138 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
HAS Super
ASTM A193 B7
HAS SS
AISI 304/316 SS
Nominal
anchor
diameter
in.
Tensile
Shear
Tensile
Shear
Tensile
Shear
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
3/8
2,640
(11.7)
1,360
(6.0)
4,555
(20.3)
2,345
(10.4)
3,645
(16.2)
1,875
(8.3)
1/2
4,700
(20.9)
2,420
(10.8)
8,100
(36.0)
4,170
(18.5)
6,480
(28.8)
3,335
(14.8)
5/8
7,340
(32.7)
3,780
(16.8)
12,655
(56.3)
6,520
(29.0)
10,125
(45.0)
5,215
(23.2)
3/4
10,570
(47.0)
5,445
(24.2)
18,225
(81.1)
9,390
(41.8)
12,390
(55.1)
6,385
(28.4)
7/8
14,385
(64.0)
7,410
(33.0)
24,805
(110.3)
12,780
(56.9)
16,865
(75.0)
8,690
(38.6)
18,790
(83.6)
9,680
(43.0)
32,400
(144.1)
16,690
(74.2)
22,030
(98.0)
11,350
(50.5)
29,360
15,125
50,620
26,080
34,425
17,735
(130.6)
(67.3)
(225.2)
(116.0)
(153.1)
(78.9)
1-1/4
3.2.3
3.2.4
3.2.4
Table 7 - Ultimate steel strength for carbon steel and stainless steel HAS rods1
Nominal
anchor
diameter
in.
HAS-E
ISO 898 Class 5.8
HAS Super
ASTM A193 B7
3.2.4
HAS SS
AISI 304/316 SS
Yield
Tensile
Shear
Yield
Tensile
Shear
Yield
Tensile
Shear
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
4,495
(20.0)
6,005
(26.7)
3,605
(16.0)
8,135
(36.2)
10,350
(43.4)
6,210
(27.6)
5,035
(22.4)
8,280
(36.8)
4,970
(22.1)
3.2.6
8230
10,675
(47.5)
6,405
(28.5)
14,900
(66.3)
18,405
(79.0)
11,040
(49.1)
9,225
(41.0)
14,720
(65.5)
8,835
(39.3)
3.2.7
(58.3)
16,680
(74.2)
10,010
(44.5)
23,730
(105.6)
28,760
(125.7)
17,260
(76.8)
14,690
(65.3)
23,010
(102.4)
13,805
(61.4)
3.2.8
3/4
19,400
(86.3)
24,020
(106.9)
14,415
(64.1)
35,120
(156.2)
41,420
(185.7)
24,850
(110.5)
15,050
(66.9)
28,165
(125.3)
16,800
(75.2)
7/8
26,780
(119.1)
32,695
(145.4)
19,620
(87.3)
48,480
(215.7)
56,370
(256.9)
33,825
(150.5)
20,775
(92.4)
38,335
(170.5)
23,000
(102.3)
35,130
(156.3)
42,705
(190.0)
25,625
(114.0)
63,600
(282.9)
73,630
(337.0)
44,180
(196.5)
27,255
(121.2)
50,070
(222.7)
30,040
(133.6)
56,210
66,730
40,035
101,755
115,050
69,030
43,610
78,235
46,940
(250.0)
(296.8)
(178.1)
(452.6)
(511.8)
(307.1)
(194.0)
(348.0)
(208.8)
3/8
1/2
5/8
1-1/4
(36.6)
13110
3.2.5
1 Steel strength as defined in AISC Manual of Steel Construction 2nd Ed. (LRFD):
Yield = F y x tensile stress area
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 139
Effective
embedment
in. (mm)
ASTM F593
stainless steel
Tensile
(13.8 MPa)
lb (kN)
Shear
(13.8 MPa)
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
4-3/8
2,870
1,565
4,370
2,250
3,645
1,875
(110)
(12.8)
(7.0)
(19.4)
(10.0)
(16.2)
(8.3)
4,530
2,890
7,775
4,005
6,480
3,335
(127)
(20.1)
(12.9)
(34.6)
(17.8)
(28.8)
(14.8)
6-5/8
8,255
4,635
12,150
6,260
10,125
5,215
(168)
(36.7)
(20.6)
(54.0)
(27.8)
(45.0)
(23.2)
8-1/4
9,030
6,695
17,945
9,010
12,395
6,385
(210)
(40.1)
(29.8)
(77.8)
(40.1)
(55.1)
(28.4)
Table 9 - HIT-RE 500 ultimate bond or concrete capacity and steel strength for HIS-N and HIS-RN inserts1
HIT-RE 500 ultimate bond/concrete
capacity
Thread
size
in.
3/8-16 UNC
1/2-13 UNC
5/8-11 UNC
3/4-10 UNC
ASTM F593
stainless steel
Effective
embedment
in. (mm)
Tensile
(13.8 MPa)
lb (kN)
Shear
(13.8 MPa)
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
4-3/8
11,480
6,260
9,935
5,960
8,280
4,970
(110)
(51.0)
(27.8)
(44.2)
(26.5)
(36.8)
(22.1)
18,115
11,565
17,665
10,600
14,720
8,835
(127)
(80.5)
(51.4)
(78.6)
(47.2)
(65.5)
(39.3)
6-5/8
33,025
18,550
27,610
16,565
23,010
13,805
(168)
(146.9)
(82.5)
(122.8)
(73.7)
(102.4)
(61.4)
8-1/4
36,125
26,775
39,760
23,855
28,165
16,900
(210)
(160.6)
(119.1)
(176.9)
(106.1)
(125.3)
(75.1)
1 Use lower value of either allowable bond/concrete capacity or steel strength. Minimum concrete compressive strength 'c is 2,000 psi.
140 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Rebar
size
Effective
embedment
in. (mm)
Ultimate
bond
strength
lb (kN)
3-3/8
(86)
4-1/2
(114)
4-1/2
(114)
6
(152)
5-5/8
(143)
7-1/2
(191)
6-3/4
(171)
9
(229)
7-7/8
(200)
10-1/2
(267)
9
(229)
12
(305)
10-1/8
(257)
13-1/2
(343)
11-1/4
(286)
15
(381)
12-3/8
(314)
16-1/2
(419)
10,105
(45.0)
10,920
(48.6)
15,980
(71.1)
18,830
(83.8)
20,630
(91.8)
24,870
(110.6)
33,695
(149.9)
38,960
(173.3)
40,525
(180.3)
48,460
(215.6)
63,940
(284.4)
69,610
(309.7)
72,245
(321.4)
94,205
(419.1)
92,000
(409.3)
95,850
(426.4)
118,615
(527.6)
123,570
(549.7)
#3
#4
#5
#6
#7
#8
#9
#10
#11
Grade 60 rebar
Embed. to
develop
yield
strength1
in. (mm)
Embed. to
develop
tensile
strength1
in. (mm)
2-1/4
(57)
3-3/8
(86)
3-3/8
(86)
5-5/8
(143)
5-1/8
(130)
8-7/8
(225)
5-3/8
(136)
9-3/8
(238)
7
(178)
12-3/8
(314)
8-1/4
(210)
12-7/8
(327)
8-1/2
(216)
13
(330)
9-3/8
(238)
17-7/8
(454)
9-7/8
(251)
18-3/4
(476)
Ultimate
bond
strength
lb (kN)
Embed. to
develop
yield
strength1
in. (mm)
Embed. to
develop
tensile
strength1
in. (mm)
Yield
strength
lb (kN)
Tensile
strength
lb (kN)
2-1/8
(54)
3-1/4
(84)
6,600
(29.4)
9,900
(44.0)
3
(76)
4-3/8
(111)
12,000
(53.4)
18,000
(80.1)
10,810
(48.1)
10,810
(48.1)
18,540
(82.5)
18,655
(83.0)
27,790
(123.6)
27,790
(128.6)
44,675
(198.7)
44,870
(200.0)
59,340
(264.0)
61,720
(274.6)
72,820
(323.9)
72,950
(324.5)
81,235
(361.4)
84,015
(373.7)
96,725
(430.3)
97,070
(431.8)
123,120
(547.7)
123,790
(550.7)
3.2.3
3-7/8
(98)
5-3/4
(146)
18,600
(82.7)
27,900
(124.1)
4
(102)
6
(152)
26,400
(117.4)
39,600
(176.2)
4-7/8
(124)
7-1/4
(184)
36,000
(160.1)
54,000
(240.2)
3.2.4
3.2.4
3.2.4
5-7/8
(149)
8-7/8
(225)
47,400
(210.9)
71,100
(316.3)
7-1/2
(191)
12
(305)
60,000
(266.9)
90,000
(400.4)
8-7/8
(225)
14
(356)
76,200
(339.0)
114,300
(508.5)
9-1/2
(241)
16-1/2
(419)
93,600
(416.4)
140,400
(624.6)
3.2.5
3.2.6
3.2.7
3.2.8
1 Based on comparison of average ultimate adhesive bond test values versus minimum yield and ultimate tensile strength of rebar. For more
information, contact Hilti.
Table 11 - HIT-RE 500 ultimate tensile bond strength for smooth epoxy coated dowel bars in concrete1
Dowel bar
diameter
in.
Nominal bit
diameter
in.
1-1/8
1-1/4
1-3/8
1-1/2
1-5/8
Embedment
depth
in. (mm)
Ultimate
tensile load
lb (kN)
9
(229)
40,385
(179.7)
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 141
s
h ef
s min
s cr
=
=
=
=
Actual spacing
Actual embedment
0.5 h ef
1.5 h ef
c
h ef
cmin
ccr
ll
=
=
=
=
=
=
=
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3(s/hef) + 0.55
for scr>s>smin
Edge distance tension
cmin = 0.5 hef
ccr = 1.5 hef
RN = 0.3(c/hef) + 0.55
for ccr>c>cmin
Edge distance shear
toward edge
cmin = 0.5 hef
ccr = 2.0 hef
RV1 = 0.54(c/hef) 0.09
for ccr>c>cmin
Diameter
Adjustment
factor
3/8-in.
Spacing
tension/shear
A
Embedment
1-3/4
depth, in.
7/8
1
1 11/16
2
2 1/4
2 5/8
3
3 1/2
4
5 1/16
5 1/2
6
6 3/4
8
9
0.70
0.72
0.84
0.89
0.94
1.00
3-3/8
0.70
0.73
0.75
0.78
0.82
0.86
0.91
1.00
4-1/2
0.70
0.73
0.75
0.78
0.82
0.89
0.92
0.95
1.00
Edge distance
tension
RN
1-3/4
0.70
0.72
0.84
0.89
0.94
1.00
3-3/8
0.70
0.73
0.75
0.78
0.82
0.86
0.91
1.00
4-1/2
0.70
0.73
0.75
0.78
0.82
0.89
0.92
0.95
1.00
( toward edge)
RV1
1-3/4
0.18
0.22
0.43
0.53
0.60
0.72
0.84
1.00
3-3/8
0.18
0.22
0.27
0.33
0.39
0.47
0.55
0.72
0.79
0.87
1.00
4-1/2
0.18
0.23
0.27
0.33
0.39
0.52
0.57
0.63
0.72
0.87
1.00
RV2
1-3/4
0.46
0.49
0.63
0.69
0.74
0.82
0.90
1.00
3-3/8
0.46
0.49
0.52
0.56
0.60
0.65
0.71
0.82
0.87
0.92
1.00
4-1/2
0.46
0.49
0.52
0.56
0.60
0.69
0.72
0.76
0.82
0.92
1.00
142 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
1/2-in.
Embedment
2-1/4
depth, in.
1-1/8
1-1/2
1-3/4
2
2-1/4
2-1/2
3
3-3/8
4
4-1/2
5
6
6-3/4
7
8
9
10
11
12
Edge distance
tension
RN
Spacing
tension/shear
A
0.70
0.75
0.78
0.82
0.85
0.88
0.95
1.00
4-1/2
0.70
0.72
0.75
0.78
0.82
0.85
0.88
0.95
1.00
2-1/4
0.70
0.72
0.75
0.78
0.80
0.85
0.89
0.90
0.95
1.00
0.70
0.75
0.78
0.82
0.85
0.88
0.95
1.00
RV1
0.70
0.72
0.75
0.78
0.82
0.85
0.88
0.95
1.00
2-1/4
0.70
0.72
0.75
0.78
0.80
0.85
0.89
0.90
0.95
1.00
0.18
0.27
0.33
0.39
0.45
0.51
0.63
0.72
0.87
1.00
4-1/2
0.18
0.21
0.27
0.32
0.39
0.45
0.51
0.63
0.72
0.75
0.87
1.00
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3 (s/hef) + 0.55
for scr>s>smin
(II to or away
from edge)
( toward edge)
4-1/2
RV2
2-1/4
0.18
0.21
0.27
0.32
0.36
0.45
0.52
0.54
0.63
0.72
0.81
0.90
1.00
0.46
0.52
0.56
0.60
0.64
0.68
0.76
0.82
0.92
1.00
4-1/2
0.46
0.48
0.52
0.55
0.60
0.64
0.68
0.76
0.82
0.84
0.92
1.00
0.46
0.48
0.52
0.55
0.58
0.64
0.69
0.70
0.76
0.82
0.88
0.94
1.00
Table 14 - Load adjustment factors for 5/8-in. and 3/4-in. diameter anchors
Diameter
Adjustment
factor
5/8-in.
Spacing
tension/shear
A
Embedment
depth, in. 2-7/8
1-7/16 0.70
1-11/16 0.73
2
0.76
2-13/16 0.84
3-3/8 0.90
3-3/4 0.94
4-5/16 1.00
4-1/2
5-1/16
5-5/8
5-3/4
6-3/4
8-7/16
10-1/8
11-1/4
12
13-1/2
15
16
18
Edge distance
tension
RN
( toward edge)
RV1
Edge distance
shear
(II to or away
from edge)
RV2
Spacing
tension/shear
A
5-5/8 7-1/2 2-7/8 5-5/8 7-1/2 2-7/8 5-5/8 7-1/2 2-7/8 5-5/8 7-1/2 3-3/8 6-3/4
0.70
0.73
0.76
0.70
0.84
0.73
0.90
0.75 0.70 0.94
0.78 0.72 1.00
0.79 0.73
0.82 0.75
0.85 0.78
0.86 0.78
0.91 0.82
1.00 0.89
0.96
1.00
0.70
0.73
0.75
0.78
0.79
0.82
0.85
0.86
0.91
1.00
0.70
0.72
0.73
0.75
0.78
0.78
0.82
0.89
0.96
1.00
0.18
0.23
0.29
0.44
0.54
0.61
0.72
0.76
0.86
0.97
1.00
0.18
0.23
0.27
0.32
0.34
0.40
0.45
0.46
0.56
0.72
0.88
1.00
0.18
0.22
0.23
0.27
0.32
0.32
0.40
0.52
0.64
0.72
0.77
0.88
1.00
0.46
0.49
0.53
0.63
0.70
0.75
0.82
0.84
0.91
0.98
1.00
0.46
0.50
0.52
0.56
0.57
0.60
0.64
0.65
0.71
0.82
0.93
1.00
0.46
0.49
0.50
0.52
0.55
0.56
0.60
0.69
0.77
0.82
0.86
0.93
1.00
0.70
0.73
0.80
0.85
0.88
0.93
0.95
1.00
Edge distance
tension
RN
3-3/8 6-3/4
0.70
0.73
0.80
0.70
0.85
0.72
0.88
0.74
0.93
0.75 0.70 0.95
0.78 0.72 1.00
0.80 0.74
0.81 0.74
0.85 0.78
0.93 0.83
1.00 0.89
0.93
0.95
1.00
0.70
0.72
0.74
0.75
0.78
0.80
0.81
0.85
0.93
1.00
0.70
0.72
0.74
0.74
0.78
0.83
0.89
0.93
0.95
1.00
Edge distance
shear
( toward edge)
RV1
3-3/8 6-3/4
0.18
0.23
0.36
0.45
0.51
0.60
0.63
0.72
0.81
0.83
1.00
3.2.4
3.2.4
3.2.4
3/4-in.
Edge distance
shear
3.2.3
0.18
0.21
0.26
0.27
0.32
0.36
0.37
0.45
0.59
0.72
0.81
0.87
1.00
0.18
0.21
0.25
0.26
0.32
0.42
0.52
0.59
0.63
0.72
0.81
0.87
1.00
Edge distance
shear
(II to or away
from edge)
RV2
3-3/8 6-3/4
0.46
0.49
0.58
0.64
0.68
0.74
0.76
0.82
0.88
0.89
1.00
3.2.5
3.2.6
3.2.7
0.46
0.48
0.51
0.52
0.55
0.58
0.59
0.64
0.73
0.82
0.88
0.92
1.00
3.2.8
0.46
0.48
0.51
0.51
0.55
0.62
0.69
0.73
0.76
0.82
0.88
0.92
1.00
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 143
7/8-in.
Embedment
depth, in.
2
2-1/2
3
3-1/2
3-15/16
4-1/2
5
5-1/4
6
6-1/2
7
8
10
11-13/16
12
14
15-3/4
18
20
21
Edge distance
tension
RN
Spacing
tension/shear
A
Adjustment
factor
4
0.70
0.74
0.78
0.81
0.85
0.89
0.93
0.94
1.00
7-7/8
10-1/2
0.70
0.72
0.74
0.75
0.78
0.80
0.82
0.85
0.93
1.00
0.70
0.72
0.74
0.75
0.78
0.84
0.89
0.89
0.95
1.00
4
0.70
0.74
0.78
0.81
0.85
0.89
0.93
0.94
1.00
7-7/8
RV1
4
0.18
0.25
0.32
0.38
0.44
0.52
0.59
0.62
0.72
0.79
0.86
1.00
0.70
0.72
0.74
0.75
0.78
0.84
0.89
0.89
0.95
1.00
7-7/8
0.18
0.22
0.25
0.27
0.32
0.36
0.39
0.46
0.60
0.72
0.73
0.87
1.00
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3 (s/hef) + 0.55
for scr>s>smin
(II to or away
from edge)
( toward edge)
10-1/2
0.70
0.72
0.74
0.75
0.78
0.80
0.82
0.85
0.93
1.00
RV2
10-1/2
7-7/8
0.46
0.51
0.55
0.60
0.63
0.69
0.73
0.75
0.82
0.87
0.91
1.00
0.18
0.22
0.24
0.27
0.32
0.42
0.52
0.53
0.63
0.72
0.84
0.94
1.00
0.46
0.49
0.51
0.52
0.55
0.58
0.60
0.65
0.74
0.82
0.83
0.92
1.00
10-1/2
Table 16 - Load adjustment factors for 1-in. and 1-1/4-in. diameter anchors
Diameter
Adjustment
factor
1-in.
Spacing
tension/shear
A
Embedment
depth, in. 4-1/2
2-1/4 0.70
2-3/4 0.73
3
0.75
4
0.82
4-1/2 0.85
5
0.88
5-5/8 0.93
6
0.95
6-3/4 1.00
7-1/2
8-1/4
9
10
11
12
13-1/2
14
16-7/8
18
20
22-1/2
24
27
30
12
Edge distance
tension
RN
4-1/2
0.70
0.73
0.75
0.82
0.70
0.85
0.72
0.88
0.74
0.93
0.75 0.70 0.95
0.78 0.72 1.00
0.80 0.74
0.83 0.76
0.85 0.78
0.88 0.80
0.92 0.83
0.95 0.85
1.00 0.89
0.90
0.97
1.00
0.70
0.72
0.74
0.75
0.78
0.80
0.83
0.85
0.88
0.92
0.95
1.00
12
0.70
0.72
0.74
0.76
0.78
0.80
0.83
0.85
0.89
0.90
0.97
1.00
1-1/4-in.
Edge distance
shear
( toward edge)
RV1
4-1/2
0.18
0.24
0.27
0.39
0.45
0.51
0.59
0.63
0.72
0.81
0.90
1.00
0.18
0.21
0.25
0.27
0.32
0.36
0.41
0.45
0.51
0.57
0.63
0.72
0.75
0.92
1.00
12
0.18
0.21
0.25
0.28
0.32
0.36
0.41
0.45
0.52
0.54
0.67
0.72
0.81
0.92
1.00
Edge distance
shear
(II to or away
from edge)
RV2
4-1/2
0.46
0.50
0.52
0.60
0.64
0.68
0.73
0.76
0.82
0.88
0.94
1.00
0.46
0.48
0.51
0.52
0.55
0.58
0.61
0.64
0.68
0.72
0.76
0.82
0.84
0.96
1.00
12
0.46
0.48
0.51
0.53
0.55
0.58
0.61
0.64
0.69
0.70
0.79
0.82
0.88
0.96
1.00
Spacing
tension/shear
A
Edge distance
tension
RN
5-5/8 11-1/4 15
5-5/8 11-1/4 15
0.70
0.71
0.76
0.79
0.82
0.85
0.87
0.91
0.95
0.99
1.00
0.70
0.71
0.76
0.79
0.82
0.70
0.85
0.71
0.87
0.73
0.91
0.75 0.70 0.95
0.77 0.72 0.99
0.79 0.73 1.00
0.82 0.75
0.84 0.77
0.87 0.79
0.91 0.82
0.92 0.83
1.00 0.89
0.91
0.95
1.00
0.70
0.71
0.73
0.75
0.77
0.79
0.82
0.84
0.87
0.91
0.92
1.00
0.70
0.72
0.73
0.75
0.77
0.79
0.82
0.83
0.89
0.91
0.95
1.00
Edge distance
shear
( toward edge)
RV1
Edge distance
shear
(II to or away
from edge)
RV2
5-5/8 11-1/4 15
5-5/8 11-1/4 15
0.18
0.20
0.29
0.34
0.39
0.45
0.49
0.56
0.63
0.70
0.77
0.87
1.00
0.46
0.47
0.54
0.57
0.60
0.64
0.66
0.71
0.76
0.81
0.86
0.92
0.98
1.00
0.18
0.20
0.23
0.27
0.31
0.34
0.39
0.44
0.49
0.56
0.58
0.72
0.77
0.87
1.00
0.18
0.21
0.23
0.27
0.31
0.34
0.40
0.41
0.52
0.56
0.63
0.72
0.77
0.88
1.00
0.46
0.47
0.50
0.52
0.54
0.57
0.60
0.63
0.66
0.71
0.73
0.82
0.86
0.92
1.00
0.46
0.48
0.50
0.52
0.54
0.57
0.60
0.62
0.69
0.71
0.76
0.82
0.86
0.93
1.00
144 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Chemicals Tested
Alkaline
Acids
Solvents
Chemicals
used on job
sites
Environmental
chemicals
Resistant
Benzyl alcohol
Ethanol
Ethyl acetate
Methyl ethyl ketone (MEK)
Trichlorethylene
Xylene (mixture)
Concrete plasticizer
Diesel oil
Oil
Petrol
Oil for form work (forming oil)
Salt water
de-mineralized water
salt spraying test
SO2
Environment/weather
Not
Resistant
+
+
+
+
+
+
+
+
+
+
+
+
+
+
37.5% at 212F
100% at 120F
100% at 23F
Approximate
full curing time
23
72 h
32
50 h
50
10
24 h
68
20
12 h
86
30
8h
104
40
4h
3.2.3
3.2.4
Approximate
initial cure time
23
36 h
32
25 h
50
10
12 h
68
20
6h
86
30
4h
104
40
2h
3.2.5
3.2.6
3.2.7
3.2.4
Approximate
gel time
23
4h
32
3h
50
10
2h
68
20
30 min
86
30
20 min
104
40
12 min
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 145
Nominal
bit
diameter
in.
Adhesive volume
required
per Inch of
embedment in 3
1/4
5/16
0.055
3/8
7/16
0.095
1/2
9/16
0.133
5/8
3/4
0.261
3/4
7/8
0.326
7/8
0.391
1-1/8
0.478
1-1/4
1-3/8
0.626
Rebar
Size
Nominal bit1
diameter
in.
Adhesive
volume
required
per Inch of
embedment
in 3
#3
1/2
0.110
#4
5/8
0.146
#5
3/4
0.176
#6
7/8
0.218
#7
0.252
#8
1-1/8
0.299
#9
1-3/8
0.601
#10
1-1/2
0.659
#11
1-3/4
1.037
146 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
HDE 500
Battery
Dispenser
HIT REMixer
P3500
Dispenser
HDM 500
Manual
Dispenser
3.2.3
HIT-RE 500 47.3 oz
(1400 ml)
P8000D
Dispenser
3.2.4
Order information
Description
Package contents
Includes (1) refill pack and (1) mixer with filler tube
Includes (25) refill packs and (25) mixer with filler tube
25
Includes (20) refil packs and (20) mixer with filler tube
20
1 For complete information about Hilti anchors, adhesive anchoring dispensers, drilled hole preparation and other adhesive anchoring accessories, see HIT-HY 200
Anchoring System, Section 3.2.3.5 Ordering Information.
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 147
Notes
148 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.2.6.1
Product description
3.2.6.2
Material specifications
3.2.6.3
Technical data
3.2.6.4
Installation instructions
3.2.6.5
Ordering information
HIT-ICE cartridge
LEED Credit 4.1-Low Emitting
Materials
The Leadership in Energy and
Environmental Design (LEED ) Green
Building Rating systemTM is the nationally
accepted benchmark for the design,
construction and operation of high
performance green buildings.
3.2.3
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 149
72 MPa
12 MPa
10,440 psi
1,740 psi
2.4%
2x1011 OHM/cm 5.1x1011 OHM/in.
150 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Symbol
Units
do
hef,std
Installation torque
Embedment hef,std
Tinst1
Installation torque
Embedment < hef,std
Tinst1
hmin
1/2
5/8
3/4
7/8
1-1/4
in.
7/16
9/16
11/16
13/16
15/16
1-1/16
1-1/2
in.
3-1/2
4-1/4
6-5/8
7-1/2
8-1/4
12
(mm)
(90)
(110)
(125)
(170)
(190)
(210)
(305)
ft-lb
18
30
75
150
175
235
400
(Nm)
(24)
(41)
(102)
(203)
(237)
(319)
(540)
ft-lb
15
20
50
105
125
165
280
(Nm)
(20)
(27)
(68)
(142)
(169)
(224)
(375)
hef+2
hef+2 1/4
in.
(mm)
hef+2
hef+52
hef+2
hef+2
hef+52
hef+2
hef+52
hef+52
hef+52
hef+57
hef+3
hef+76
3.2.3
Thread size
Symbol
Units
in.
0.65
0.81
1.00
1.09
do
in.
11/16
7/8
1-1/8
1-1/4
in.
4-3/8
6-3/4
8-1/8
(mm)
(110)
(125)
(170)
(205)
in.
3/8
1/2
5/8
3/4
in.
15/16
1-3/16
1-1/2
1-7/8
ft-lb
15
30
60
100
(Nm)
(20)
(40)
(81)
(136)
in.
5.9
6.7
9.1
10.6
(mm)
(150)
(170)
(230)
(270)
Effective embedment
hef
minimum
Thread engagement
hs
maximum
Installation torque
Tinst
Concrete thickness
hmin
3.2.4
3.2.4
3.2.4
3.2.5
Symbol
Units
do
in.
3.2.6
Rebar size
No. 3
No. 4
No. 5
No. 6
No. 7
No. 8
No. 9
No. 10
No. 11
1/2
5/8
3/4
7/8
1-1/8
1-3/8
1-1/2
1-9/16
1 1 Rebar diameters may vary. Use the smallest drill bit which will accomodate the rebar.
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 151
3/8
1/2
5/8
3/4
7/8
1-1/4
Tensile
Effective
embedment
in. (mm)
1-3/4
(44)
3-1/2
(89)
5-1/4
(133)
2-1/8
(54)
4-1/4
(108)
6-3/8
(162)
2-1/2
(64)
5
(127)
7-1/2
(191)
3-3/8
(86)
6-5/8
(168)
10
(254)
3-3/4
(95)
7-1/2
(191)
11-1/4
(286)
4-1/8
(105)
8-1/4
(210)
12-3/8
(314)
6
(152)
12
(305)
15
(381)
HIT-ICE
ultimate bond/concrete capacity
Shear
Tensile
Shear
'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi
(13.8 MPa)
(27.6 MPa)
(13.8 MPa)
(27.6 MPa)
(13.8 MPa)
(27.6 MPa)
(13.8 MPa)
(27.6 MPa)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
720
(3.2)
1,265
(5.6)
1,395
(6.2)
1,970
(8.8)
2,710
(12.1)
4,750
(21.1)
4,175
(18.6)
5,900
(26.2)
1,895
(8.4)
2,705
(12.0)
3,335
(14.8)
4,715
(21.0)
7,120
(31.7)
10,160
(45.2)
10,000
(44.5)
14,140
(62.9)
2,635
(11.7)
2,800
(12.5)
6,120
(27.2)
8,655
(38.5)
9,880
(44.0)
10,510
(46.8)
18,360
(81.7)
25,960
(115.5)
1,220
(5.4)
1,575
(7.0)
1,980
(8.8)
2,800
(12.5)
4,580
(20.4)
5,910
(26.3)
5,940
(26.4)
8,400
(37.4)
2,725
(12.1)
3,935
(17.5)
5,150
(22.9)
7,280
(32.4)
10,220
(44.5)
14,760
(65.7)
15,440
(68.7)
21,840
(97.1)
4,300
(19.1)
5,295
(23.6)
9,455
(42.1)
13,375
(59.5)
16,140
(71.8)
19,860
(88.3)
28,360
(126.2)
40,120
(178.5)
1,620
(7.2)
1,985
(8.8)
2,460
(10.9)
3,480
(15.5)
6,090
(27.1)
7,460
(33.2)
7,380
(32.8)
10,440
(46.4)
4,395
(19.5)
5,250
(23.4)
7,350
(32.7)
10,390
(46.2)
16,480
(73.3)
19,690
(87.6)
22,040
(98.0)
31,160
(138.6)
6,025
(26.8)
8,225
(36.6)
13,495
(60.0)
19,080
(84.9)
22,595
(100.5)
30,850
(137.2)
40,480
(180.0)
57,240
(254.6)
2,365
(10.5)
3,925
(17.5)
5,435
(24.2)
7,680
(34.2)
8,870
(39.5)
14,720
(65.5)
16,295
(72.5)
23,040
(102.5)
4,655
(20.7)
8,885
(39.5)
12,270
(54.6)
17,355
(77.2)
17,460
(77.7)
33,330
(148.3)
36,800
(163.7)
52,060
(231.6)
9,515
(42.3)
12,140
(54.0)
22,755
(101.2)
32,180
(143.1)
35,695
(158.8)
45,530
(202.5)
68,260
(303.6)
96,540
(429.4)
3,080
(13.7)
4,800
(21.4)
6,705
(29.8)
9,480
(42.4)
11,555
(51.4)
18,000
(80.1)
20,105
(89.4)
28,430
(126.5)
7,845
(34.9)
11,020
(49.0)
15,960
(71.0)
22,575
(100.4)
29,430
(130.9)
41,000
(182.3)
47,880
(213.0)
67,720
(301.2)
13,330
(59.3)
16,645
(74.0)
29,330
(130.5)
41,475
(184.5)
49,990
(222.4)
62,425
(277.7)
87,980
(391.4)
12,4420
(553.4)
3,445
(15.3)
4,865
(21.6)
8,265
(36.8)
11,685
(52.0)
12,920
(57.5)
18,250
(81.2)
24,790
(110.3)
35,050
(155.9)
8,330
(37.1)
15540
(69.1)
4645
(20.7)
11,635
(51.8)
19,690
(87.6)
27,840
(123.8)
31,250
(139.0)
43,640
(194.1)
59,060
(262.7)
83,520
(371.5)
19,525
(86.8)
36,170
(160.9)
51,150
(227.5)
58,280
(259.3)
73,220
(325.7)
108,500
(482.6)
153,440
(682.5)
7,000
(31.1)
14,760
(65.7)
20,870
(92.8)
17,430
(77.5)
26,265
(116.8)
44,280
(197.0)
62,610
(278.5)
15,490
(68.9)
20,770
(92.4)
38,615
(171.8)
54,610
(242.9)
58,085
(258.4)
77,900
(346.5)
115,840
(515.3)
163,820
(728.7)
19,210
(85.5)
26,815
(119.3)
53,960
(240.0)
76,315
(339.5)
72,040
(320.5)
100,560
(447.3)
161,880
(720.1)
228,940
(1018.4)
1 Influence factors for spacing and/or edge distance are applied to concrete/bond values above, and then compared to the steel value. The
lesser of the values is to be used for the design.
2 For hef hef,std average ultimate concrete shear capacity based on Strength Design method. For hef < hef,std average ultimate concrete shear
values based on testing.
152 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
HAS-E
ISO 898 Class 5.8
HAS Super
ASTM A193 B7
HAS SS
AISI 304/316 SS
Tensile
lb (kN)
Shear
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
2,640
1,360
4,555
2,345
3,645
1,875
(11.7)
(6.0)
(20.3)
(10.4)
(16.2)
(8.3)
4,700
2,420
8,100
4,170
6,480
3,335
(20.9)
(10.8)
(36.0)
(18.5)
(28.8)
(14.8)
7,340
3,780
12,655
6,520
10,125
5,215
(32.7)
(16.8)
(56.3)
(29.0)
(45.0)
(23.2)
10,570
5,445
18,225
9,390
12,390
6,385
(47.0)
(24.2)
(81.1)
(41.8)
(55.1)
(28.4)
14,385
7,410
24,805
12,780
16,865
8,690
(64.0)
(33.0)
(110.3)
(56.9)
(75.0)
(38.6)
18,790
9,680
32,400
16,690
22,030
11,350
(83.6)
(43.0)
(144.1)
(74.2)
(98.0)
(50.5)
29,360
15,125
50,620
26,080
34,425
17,735
(130.6)
(67.3)
(225.2)
(116.0)
(153.1)
(78.9)
3.2.3
3.2.4
3.2.4
Table 7 - Ultimate steel strength for carbon steel and stainless steel HAS rods1
Nominal
anchor
diameter
in.
3/8
1/2
5/8
3/4
7/8
1
1-1/4
HAS-E
ISO 898 Class 5.8
HAS Super
ASTM A193 B7
3.2.4
HAS SS
AISI 304/316 SS
Yield
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Yield
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Yield
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
4,495
6,005
3,605
8,135
10,350
6,210
5,035
8,280
4,970
(20.0)
(26.7)
(16.0)
(36.2)
(43.4)
(27.6)
(22.4)
(36.8)
(22.1)
8,230
10,675
6,405
14,900
18,405
11,040
9,225
14,720
8,835
(36.6)
(47.5)
(28.5)
(66.3)
(79.0)
(49.1)
(41.0)
(65.5)
(39.3)
13,110
16,680
10,010
23,730
28,760
17,260
14,690
23,010
13,805
(58.3)
(74.2)
(44.5)
(105.6)
(125.7)
(76.8)
(65.3)
(102.4)
(61.4)
19,400
24,020
14,415
35,120
41,420
24,850
15,050
28,165
16,800
(86.3)
(106.9)
(64.1)
(156.2)
(185.7)
(110.5)
(66.9)
(125.3)
(75.2)
26,780
32,695
19,620
48,480
56,370
33,825
20,775
38,335
23,000
(119.1)
(145.4)
(87.3)
(215.7)
(256.9)
(150.5)
(92.4)
(170.5)
(102.3)
35,130
42,705
25,625
63,600
73,630
44,180
27,255
50,070
30,040
(156.3)
(190.0)
(114.0)
(282.9)
(337.0)
(196.5)
(121.2)
(222.7)
(133.6)
56,210
66,730
40,035
101,755
115,050
69,030
43,610
78,235
46,940
(250.0)
(296.8)
(178.1)
(452.6)
(511.8)
(307.1)
(194.0)
(348.0)
(208.8)
3.2.5
3.2.6
3.2.7
3.2.8
1 Steel strength as defined in AISC Manual of Steel Construction 2nd Ed. (LRFD).
Yield = Fy x tensile stress area
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 153
Thread
size.
3/8-16 UNC
1/2-13 UNC
5/8-11 UNC
3/4-10 UNC
Effective
embedment
in. (mm)
4-3/8
(110)
5
(127)
6-5/8
(168)
8-1/4
(210)
ASTM F593
stainless steel
Tensile
lb (kN)
Shear
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
2,750
(12.2)
1,605
(7.1)
4,370
(19.4)
2,250
(10.0)
3,645
(16.2)
1,875
(8.3)
4,195
(18.7)
3,040
(13.5)
7,775
(34.6)
4,005
(17.8)
6,480
(28.8)
3,335
(14.8)
6,700
(29.8)
4,575
(20.4)
12,150
(54.0)
6,260
(27.8)
10,125
(45.0)
5,215
(23.2)
7,855
(34.9)
6,305
(28.0)
17,495
(77.8)
9,010
(40.1)
12,395
(55.1)
6,385
(28.4)
Table 9 - HIT-ICE ultimate bond or concrete capacity and steel strength for HIS-N and HIS-RN inserts1
HIT-ICE ultimate
bond/concrete capacity2
Thread
size.
3/8-16 UNC
1/2-13 UNC
5/8-11 UNC
3/4-10 UNC
Effective
embedment
in. (mm)
4-3/8
(110)
5
(127)
6-5/8
(168)
8-1/4
(210)
ASTM F593
stainless steel
Tensile
lb (kN)
Shear
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
11,000
(48.9)
6,425
(28.6)
9,935
(44.2)
5,960
(26.5)
8,280
(36.8)
4,970
(22.1)
16,790
(74.7)
12,170
(54.1)
17,665
(78.6)
10,600
(47.2)
14,720
(65.5)
8,835
(39.3)
26,795
(119.2)
18,310
(81.5)
27,610
(122.8)
16,565
(73.7)
23,010
(102.4)
13,805
(61.4)
31,430
(139.8)
25,215
(112.2)
39,760
(176.9)
23,855
(106.1)
28,165
(125.3)
16,900
(75.1)
1 Use lower value of either bond, concrete capacity or steel strength. Minimum concrete compressive strength 'c is 2,000 psi.
2 Steel values in accordance with AISC
ASTM A325 bolts Fy = 92 ksi , Fu = 120 ksi
ASTM F593 (AISI 304/316) F
y = 65 ksi, Fu = 100 ksi for 3/8- through 5/8-in.
Fy = 45 ksi, Fu = 85 ksi for 3/4-in.
Allowable load values
Tension = 0.33 x Fu x Anom
Shear = 0.17 x Fu x Anom
154 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Nominal anchor
Effective
diameter
embedment
in.
in. (mm)
Tensile
Shear
Tensile
Shear
1-3/4
(44)
745
(3.3)
1,285
(5.7)
2,980
(13.3)
5,150
(22.9)
3-1/2
(89)
1,220
(5.4)
1,580
(7.0)
4,920
(21.9)
6,320
(28.1)
2-1/8
(54)
975
(4.3)
2,130
(9.5)
3,900
(17.3)
8,520
(37.9)
4-1/4
(108)
1,210
(5.4)
2,910
(12.9)
4,840
(21.5)
11,640
(51.8)
5/8
2-1/2
(63)
1,200
15.3)
2,480
(11.0)
4,800
(21.4)
9,920
(44.1)
3/4
3-3/8
(86)
1,760
(7.8)
4,000
(17.8)
7,040
(31.3)
15,985
(71.1)
3/8
1/2
3.2.3
1 Influence factors for spacing and/or edge distance are applied to allowable concrete/bond values above, and then compared to the allowable steel value.
The lesser of these values is to be used for design.
Table 11 - Allowable loads for anchorage of exterior sill plates with HIT-ICE1,2,3,4
Nominal anchor
Effective
diameter
embedment
in.
in. (mm)
1/2
5/8
4-1/4
(108)
5
(127)
edge distance
3.2.4
Tension
Shear lb (kN)
in.
(mm)
lb
(kN)
1-3/4
(45)
1,280
(5.3)
Load II to edge
1,445
Load to edge
(6.4)
400
(1.8)
2-3/4
(70)
1,800
(8.1)
2,100
(9.5)
845
(3.8)
1-3/4
(45)
1,700
(7.6)
1,445
(6.4)
400
(1.8)
2-3/4
(70)
2,725
(12.1)
2,455
(10.9)
960
(4.3)
2 Allowable loads are based on concrete capacity. The steel strength must be checked.
3 A wood 2x4 exterior plate has a 1-3/4 inch edge distance. A 2x6 has a 2-3/4 inch edge distance.
3.2.6
3.2.7
Table 12 - Allowable loads for anchorage to the top of grout-filled block walls with HIT-ICE1,2,3,4
1/2
4-1/4
(108)
5/8
5
(127)
Edge distance
3.2.4
3.2.5
Nominal anchor
Effective
diameter
embedment
in.
in. (mm)
3.2.4
Tension
Shear lb (kN)
in.
(mm)
lb
(kN)
Load II to edge
1-3/4
(45)
1,120
(5.0)
2-3/4
(70)
1,440
(6.4)
1-3/4
(45)
1,475
(6.5)
2-3/4
(70)
1,630
(7.2)
3,070
1,425
Load to edge
(6.3)
560
2,085
(9.3)
1,110
(4.9)
1,800
(8.0)
680
(3.0)
(13.7)
1,110
(4.9)
3.2.8
(2.5)
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 155
Effective
embedment
in. (mm)
3/8
3-1/2
(89)
1/2
4-1/4
(108)
5/8
5
(127)
3/4
6-5/8
(168)
(mm)
(102)
12
(305)
(102)
12
(305)
(102)
12
(305)
(102)
12
(305)
Shear lb (kN)5,6
Tension5,6
lb
(kN)
1,550
(6.9)
1,785
(7.9)
2,265
3,740
(10.1)
(16.6)
HAS-E
HAS Super
HAS SS
1360
(6.0)
2020
(9.0)
1875
(8.3)
2,020
(9.0)
2,020
(9.0)
2,020
(9.0)
2,420
(10.8)
4,170
(18.5)
3,335
(14.8)
2,020
(9.0)
2,020
(9.0)
2,020
(9.0)
3,780
(16.8)
5,625
(25.0)
5,215
(23.2)
2,020
(9.0)
2,020
(9.0)
2,020
(9.0)
5,445
(24.2)
5,625
(25.0)
5,625
(25.0)
Table 14 - HIT-ICE ultimate loads for threaded rods in grout-filled concrete masonry units1, 2, 3, 4
Nominal
anchor
diameter
in.
Distance
from edge
Effective
embedment
in. (mm)
in.
(mm)
3/8
3-1/2
(90)
(102)
12
(305)
1/2
4-1/4
(108)
(102)
12
(305)
(102)
12
(305)
(102)
12
(305)
5/8
5
(127)
3/4
6-5/8
(168)
Shear lb (kN)5,6
Tension lb (kN)5,6
HAS-E
HAS Super
HAS SS
HAS-E
HAS Super
HAS SS
6,005 (26.7) 6,200 (27.6) 6,200 (27.6) 3,605 (16.0) 6,210 (27.6) 4,970 (22.1)
7,140 (31.8) 7,140 (31.8) 7,140 (31.8) 6,405 (28.5)
9,060 (40.3) 9,060 (40.3) 9,060 (40.3)
14,970 (66.6) 14,970 (66.6) 14,970 (66.6)
1 Values are for lightweight, medium-weight or normal-weight concrete masonry units conforming to ASTM C90 with 2,000 psi grout conforming to ASTM C476.
2 Embedment depth is measured from the outside face of the concrete masonry unit.
3 Values are for anchors located in the grouted cell, head joint, bed joint, T-joint, cross web or any combination of the above.
4 Values for edge distances between 4 inches and 12 inches can be calculated by linear interpolation.
5 Loads are based on the lesser of bond strength, steel strength or base material strength.
6 Steel values in accordance with AISC
Allowable load values
Tension = 0.33 x Fu x Anom
Shear = 0.17 x Fu x Anom
156 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Rebar
size
#3
#4
#5
#6
#7
#8
#9
#10
#11
Effective
embedment
in. (mm)
1-1/2
(38)
3-1/2
(89)
7
(178)
2
(51)
4
(102)
8
(203)
2-1/2
(64)
5
(127)
10
(254)
3-1/2
(90)
7
(178)
14
(356)
3-3/4
(95)
7-1/2
(190)
15
(380)
4
(102)
8
(204)
16
(408)
5
(127)
10
(254)
18
(457)
6
(152)
12
(304)
20
(508)
7
(178)
14
(356)
20
(508)
Ultimate
bond
strength
lb (kN)
2,500
(11.1)
6,300
(28.0)
12,600
(56.0)
4,200
(18.7)
9,000
(40.0)
18,000
(80.1)
5,600
(24.9)
13,500
(60.1)
27,000
(120.1)
10,200
(45.4)
22,100
(98.3)
44,200
(196.6)
10,700
(47.6)
27,100
(120.6)
54,200
(241.1)
14,100
(62.7)
32,500
(144.6)
65,000
(289.1)
16,700
(74.3)
47,400
(210.9)
85,300
(379.4)
23,300
(103.6)
59,600
(265.1)
99,300
(441.7)
32,000
(142.3)
75,800
(337.2)
108,400
(482.2)
Embed. to
develop
yield
strength1
in. (mm)
Grade 60 rebar
Embed. to
develop
tensile
strength1
in. (mm)
3-3/4
5-1/2
(95.3)
(139.7)
5-1/2
(139.7)
(203.2)
10-1/4
(177.8)
(260.4)
8-1/2
12-3/4
(215.9)
(323.9)
10
15
(254.0)
(381)
11-3/4
17-1/2
(298.5)
(444.5)
12-3/4
19
(323.9)
(482.6)
15-1/2
23
(393.7)
(584.2)
17-1/4
26
(438.2)
(660.4)
Ultimate
bond
strength
lb (kN)
3,800
(16.9)
8,200
(36.5)
16,500
(73.4)
6,000
(26.7)
11,800
(52.5)
23,600
(105.0)
6,900
(30.7)
17,700
(78.7)
35,300
(157.0)
12,800
(56.9)
28,900
(128.6)
57,700
(256.7)
15,800
(70.3)
35,300
(157.0)
70,700
(314.5)
18,100
(80.5)
42,400
(188.6)
84,800
(377.2)
21,800
(97.0)
61,800
(274.9)
111,300
(495.1)
32,400
(144.1)
77,700
(345.6)
129,600
(576.5)
41,300
(183.7)
99,000
(440.4)
141,400
(629.0)
Embed. to
develop
yield
strength1
in. (mm)
Embed. to
develop
tensile
strength1
in. (mm)
Yield
strength
lb (kN)
Tensile
strength
lb (kN)
2-3/4
4-1/4
6,600
9,900
(69.9)
(108.0)
(29.4)
(44.0)
4-1/4
6-1/4
12,000
18,000
(108.0)
(158.8)
(53.4)
(80.1)
5-1/4
18,600
27,900
(133.4)
(203.2)
(82.7)
(124.1)
3.2.3
3.2.4
3.2.4
6-1/2
9-3/4
26,400
39,600
(165.1)
(247.7)
(117.4)
(176.2)
3.2.4
3.2.5
7-3/4
11-1/2
36,000
54,000
(196.9)
(292.1)
(160.1)
(240.2)
3.2.6
3.2.7
13-1/2
47,450
71,100
(228.6)
(342.9)
(211.1)
(316.3)
10
15-3/4
60,000
90,000
(254.0)
(400.1)
(266.9)
(400.4)
12
17-3/4
76,200
114,300
(304.8)
(450.9)
(339.0)
(508.5)
13-1/2
20
93,600
140,400
(342.9)
(508.0)
(416.4)
(624.6)
3.2.8
1 Based on comparison of average ultimate adhesive bond test values versus minimum yield and ultimate tensile strength of rebar; for more
information, contact Hilti.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 157
s
s min
s cr
h ef
=
=
=
=
Actual spacing
0.5 h ef
1.5 h ef
Actual embedment
c
cmin
c cr
h ef
=
=
=
=
=
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3(s/hef) + 0.55
for scr>s>smin
Edge distance tension
cmin = 0.5 hef
ccr = 1.5 hef
RN = 0.4(c/hef) + 0.40
for ccr>c>cmin
Edge distance shear
toward edge
cmin = 0.5 hef
ccr = 2.0 hef
RV1 = 0.54(c/hef) 0.09
for ccr>c>cmin
Diameter
3/8-in.
tension/shear
Edge distance
tension
Embedment
1-3/4
depth, in.
7/8
1-1/4
1-3/4
2
2-5/8
3
3-1/2
4
4-1/2
5-1/4
6-1/2
7
7-7/8
9
10-1/2
Spacing
Adjustment
factor
0.70
0.76
0.85
0.89
1.00
3-1/2
0.70
0.72
0.78
0.81
0.85
0.89
0.94
1.00
RN
5-1/4
0.70
0.72
0.75
0.78
0.81
0.85
0.92
0.95
1.00
1-3/4
0.60
0.69
0.80
0.86
1.00
3-1/2
0.60
0.63
0.70
0.74
0.80
0.86
0.91
1.00
5-1/4
0.60
0.63
0.67
0.70
0.74
0.80
0.90
0.93
1.00
( toward edge)
RV1
1-3/4
0.18
0.30
0.45
0.53
0.72
0.84
1.00
3-1/2
0.18
0.22
0.32
0.37
0.45
0.53
0.60
0.72
0.91
1.00
5-1/4
0.18
0.22
0.27
0.32
0.37
0.45
0.58
0.63
0.72
0.84
1.00
RV2
1-3/4
0.46
0.54
0.64
0.69
0.82
0.90
1.00
3-1/2
0.46
0.49
0.55
0.59
0.64
0.69
0.74
0.82
0.95
1.00
5-1/4
0.46
0.49
0.52
0.55
0.59
0.64
0.73
0.76
0.82
0.90
1.00
158 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
tension/shear
0.70
0.76
0.83
0.85
0.94
0.97
1.00
4-1/4
tension
0.70
0.74
0.76
0.78
0.83
0.85
0.90
0.97
1.00
RN
6-3/8
0.70
0.74
0.75
0.79
0.83
0.85
0.88
0.90
0.95
0.97
1.00
2-1/8
0.60
0.68
0.78
0.80
0.92
0.96
1.00
4-1/4
6-3/8
0.60
0.66
0.68
0.70
0.78
0.80
0.87
0.96
1.00
Edge distance
Embedment 2-1/8
depth, in.
Spacing
Adjustment
factor
1-1/16
1-1/2
2
2-1/8
2-3/4
3
3-3/16
4
4-1/4
5
6
6-3/8
7
7-1/2
8-1/2
9
9-9/16
10
11
12-3/4
1/2-in.
(II to or away
from edge)
( toward edge)
RV1
2-1/8
0.18
0.29
0.42
0.45
0.61
0.67
0.72
0.93
1.00
0.60
0.65
0.67
0.71
0.78
0.80
0.84
0.87
0.93
0.96
1.00
4-1/4
0.18
0.26
0.29
0.32
0.42
0.45
0.55
0.67
0.72
0.80
0.86
1.00
RV2
6-3/8
2-1/8
4-1/4
0.46
0.53
0.62
0.64
0.75
0.79
0.82
0.96
1.00
0.18
0.25
0.27
0.33
0.42
0.45
0.50
0.55
0.63
0.67
0.72
0.76
0.84
1.00
0.46
0.51
0.53
0.55
0.62
0.64
0.70
0.79
0.82
0.87
0.92
1.00
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3 (s/hef) + 0.55
for scr>s>smin
6-3/8
0.46
0.51
0.52
0.56
0.62
0.64
0.68
0.70
0.76
0.79
0.82
0.84
0.90
1.00
Table 18 - Load adjustment factors for 5/8-in. and 3/4-in. diameter anchors
Diameter
Adjustment
factor
5/8-in.
Spacing
tension/shear
Embedment 2-1/2
depth, in.
1-1/4
1-11/16
2
2-1/2
3
3-5/16
3-3/4
4
4-1/2
5
5-1/16
5-1/2
6
6-3/4
7-1/2
8
8-1/2
9
9-15/16
10
11-1/4
12
13-1/4
14
15
16
18
20
Edge distance
0.70
0.75
0.79
0.85
0.91
0.95
1.00
0.70
0.73
0.75
0.78
0.79
0.82
0.85
0.85
0.88
0.91
0.96
1.00
7-1/2 2-1/2
0.60
0.67
0.72
0.80
0.88
0.93
0.70 1.00
0.71
0.73
0.75
0.75
0.77
0.79
0.82
0.85
0.87
0.89
0.91
0.95
0.95
1.00
tension
RN
5
0.60
0.64
0.67
0.70
0.72
0.76
0.80
0.81
0.84
0.88
0.94
1.00
Edge distance
shear
( toward edge)
RV1
7-1/2 2-1/2
0.60
0.61
0.64
0.67
0.67
0.69
0.72
0.76
0.80
0.83
0.85
0.88
0.93
0.93
1.00
0.18
0.27
0.34
0.45
0.56
0.63
0.72
0.77
0.88
1.00
0.18
0.23
0.27
0.32
0.34
0.40
0.45
0.46
0.50
0.56
0.64
0.72
0.77
0.83
0.88
0.98
1.00
(II to or away
from edge)
RV2
7-1/2 2-1/2
0.18
0.20
0.23
0.27
0.27
0.31
0.34
0.40
0.45
0.49
0.52
0.56
0.63
0.63
0.72
0.77
0.86
0.92
1.00
0.46
0.52
0.57
0.64
0.71
0.76
0.82
0.86
0.93
1.00
0.46
0.50
0.52
0.55
0.57
0.60
0.64
0.64
0.68
0.71
0.77
0.82
0.86
0.89
0.93
1.00
Spacing
tension/shear
tension
0.46
0.47
0.50
0.52
0.52
0.54
0.57
0.60
0.64
0.66
0.69
0.71
0.76
0.76
0.82
0.86
0.92
0.95
1.00
Edge distance
0.70
0.73
0.77
0.82
0.84
0.88
0.91
0.95
0.99
1.00
10
RN
3-3/8 6-5/8
0.60
0.64
0.70
0.76
0.70
0.79
0.72
0.84
0.73
0.87
0.75
0.93
0.78 0.70 0.99
0.78 0.70 1.00
0.80 0.72
0.82 0.73
0.86 0.75
0.89 0.78
0.91 0.79
0.93 0.81
0.96 0.82
1.00 0.85
0.85
0.89
0.91
0.95
0.97
1.00
0.60
0.63
0.64
0.67
0.70
0.71
0.73
0.76
0.81
0.85
0.88
0.91
0.94
1.00
Edge distance
shear
( toward edge)
RV1
10
0.60
0.60
0.62
0.64
0.67
0.70
0.72
0.74
0.76
0.80
0.80
0.85
0.88
0.93
0.96
1.00
3-3/8 6-5/8
0.18
0.23
0.31
0.39
0.44
0.51
0.55
0.63
0.71
0.72
0.79
0.87
1.00
3.2.4
3.2.4
3.2.4
3/4-in.
Edge distance
shear
3.2.3
0.18
0.22
0.24
0.28
0.32
0.32
0.36
0.40
0.46
0.52
0.56
0.60
0.64
0.72
0.73
0.83
0.89
1.00
10
0.18
0.18
0.21
0.23
0.27
0.32
0.34
0.37
0.40
0.45
0.45
0.52
0.56
0.63
0.67
0.72
0.77
0.88
1.00
Edge distance
shear
(II to or away
from edge)
RV2
3-3/8 6-5/8
0.46
0.49
0.55
0.60
0.63
0.68
0.71
0.76
0.81
0.82
0.87
0.92
1.00
10
3.2.5
3.2.6
3.2.7
3.2.8
0.46
0.48
0.50
0.52
0.55
0.56
0.58
0.61
0.65
0.69
0.71
0.74
0.77
0.82
0.82
0.89
0.93
1.00
0.46
0.46
0.48
0.50
0.52
0.55
0.57
0.59
0.60
0.64
0.64
0.69
0.71
0.76
0.78
0.82
0.86
0.93
1.00
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 159
7/8-in.
Adjustment
factor
tension/shear
7-1/2
tension
0.70
0.75
0.79
0.85
0.87
0.91
0.95
1.00
0.70
0.71
0.73
0.75
0.78
0.79
0.81
0.83
0.85
0.87
0.89
0.91
0.95
0.95
1.00
RN
11-1/4
0.70
0.71
0.72
0.74
0.75
0.76
0.78
0.79
0.82
0.82
0.85
0.87
0.92
0.95
1.00
3-3/4
0.60
0.67
0.72
0.80
0.83
0.88
0.93
1.00
7-1/2
0.60
0.61
0.64
0.67
0.70
0.72
0.75
0.77
0.80
0.83
0.85
0.88
0.93
0.93
1.00
Edge distance
Embedment
3-3/4
depth, in.
1-7/8
2-1/2
3
3-3/4
4
4-1/2
5
5-5/8
6
6-1/2
7
7-1/2
8
8-1/2
9
9-15/16
10
11-1/4
12
14
15
16-7/8
18
20
22-1/2
Spacing
11-1/4
0.60
0.61
0.63
0.65
0.67
0.68
0.70
0.72
0.75
0.76
0.80
0.83
0.90
0.93
1.00
(II to or away
from edge)
( toward edge)
RV1
3-3/4
0.18
0.27
0.34
0.45
0.49
0.56
0.63
0.72
0.77
0.85
0.92
1.00
7-1/2
0.18
0.20
0.23
0.27
0.32
0.34
0.38
0.41
0.45
0.49
0.52
0.56
0.63
0.63
0.72
0.77
0.92
1.00
RV2
11-1/4
0.18
0.20
0.22
0.25
0.27
0.29
0.32
0.34
0.39
0.39
0.45
0.49
0.58
0.63
0.72
0.77
0.87
1.00
3-3/4
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3 (s/hef) + 0.55
for scr>s>smin
7-1/2 11-1/4
0.46
0.52
0.57
0.64
0.66
0.71
0.76
0.82
0.86
0.90
0.95
1.00
0.46
0.47
0.50
0.52
0.55
0.57
0.59
0.62
0.64
0.66
0.69
0.71
0.76
0.76
0.82
0.86
0.95
1.00
0.46
0.47
0.49
0.50
0.52
0.54
0.55
0.57
0.60
0.60
0.64
0.66
0.73
0.76
0.82
0.86
0.92
1.00
Table 20 - Load adjustment factors for 1-in. and 1-1/4-in. diameter anchors
Diameter
Adjustment
factor
1-in.
1-1/4-in.
Spacing
Edge distance
Edge distance
shear
RN
RV1
tension/shear
tension
( toward edge)
Edge distance
shear
0.70
0.77
0.80
0.85
0.91
0.95
0.99
1.00
0.70
0.73
0.75
0.77
0.78
0.82
0.85
0.88
0.90
0.91
0.93
0.99
1.00
0.60
0.69
0.74
0.80
0.88
0.93
0.98
0.70 1.00
0.73
0.75
0.77
0.78
0.79
0.80
0.84
0.85
0.89
0.95
0.99
1.00
0.18
0.30
0.37
0.60
0.45
0.64
0.56
0.67
0.63
0.69
0.70
0.70 0.60 0.72
0.76 0.64 0.89
0.80 0.67 1.00
0.84 0.69
0.86 0.71
0.88 0.72
0.91 0.74
0.98 0.79
1.00 0.80
0.85
0.93
0.98
1.00
0.46
0.54
0.59
0.18
0.64
0.24
0.72
0.27
0.76
0.30
0.80
0.32 0.18 0.82
0.40 0.24 0.93
0.45 0.27 1.00
0.50 0.30
0.53 0.32
0.56 0.35
0.60 0.37
0.70 0.43
0.72 0.45
0.83 0.52
1.00 0.63
0.70
0.72
0.78
0.89
0.96
1.00
tension/shear
RV2
Embedment
depth, in. 4-1/8 8-1/4 12-3/8 4-1/8 8-1/4 12-3/8 4-1/8 8-1/4 12-3/8 4-1/8 8-1/4 12-3/8
2-1/16
3
3-1/2
4-1/8
5
5-1/2
6
6-3/16
7-1/2
8-1/4
9
9-1/2
10
10-1/2
12
12-3/8
14
16-1/2
18
18-9/16
20
22-1/2
24
24-3/4
26
28
30
Spacing
(II to or away
from edge)
0.46
0.50
0.52
0.54
0.55
0.61
0.64
0.67
0.69
0.72
0.74
0.80
0.82
0.89
1.00
0.46
0.50
0.52
0.54
0.56
0.57
0.59
0.63
0.64
0.69
0.76
0.80
0.82
0.86
0.93
0.98
1.00
Edge distance
tension
6
0.70
0.73
0.76
0.80
0.83
0.85
0.86
0.93
0.96
1.00
12
15
RN
0.60
0.63
0.68
0.73
0.77
0.70
0.80
0.70
0.81
0.74 0.70 0.90
0.76 0.72 0.95
0.78 0.73 1.00
0.79 0.74
0.80 0.75
0.81 0.76
0.85 0.79
0.86 0.80
0.90 0.83
0.96 0.88
1.00 0.91
0.92
0.95
1.00
12
0.60
0.61
0.65
0.68
0.70
0.72
0.73
0.75
0.80
0.81
0.87
0.95
1.00
Edge distance
shear
Edge distance
shear
(II to or away
from edge)
( toward edge)
RV1
15
0.60
0.62
0.64
0.65
0.67
0.68
0.72
0.73
0.77
0.84
0.88
0.90
0.93
1.00
6
0.18
0.23
0.28
0.36
0.41
0.45
0.47
0.59
0.65
0.72
0.77
0.81
0.86
1.00
12
0.18
0.19
0.25
0.28
0.32
0.34
0.36
0.38
0.45
0.47
0.54
0.65
0.72
0.75
0.81
0.92
1.00
15
0.18
0.21
0.23
0.25
0.27
0.29
0.34
0.36
0.41
0.50
0.56
0.58
0.63
0.72
0.77
0.80
0.85
0.92
1.00
RV2
6
0.46
0.49
0.53
0.58
0.61
0.64
0.65
0.73
0.78
0.82
0.85
0.88
0.91
1.00
12
0.46
0.47
0.51
0.53
0.55
0.57
0.58
0.60
0.64
0.65
0.70
0.78
0.82
0.84
0.88
0.96
1.00
15
0.46
0.48
0.50
0.51
0.52
0.53
0.57
0.58
0.62
0.68
0.71
0.73
0.76
0.82
0.86
0.87
0.90
0.95
1.00
160 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
% of load at 70F
HIT-ICE
10
23
18
1.5 h
23
40 min
32
26 min
41
11 min
68
20
4 min
86
30
1.5 min
1.5 h
HIT-ICE
10
23
36 h
18
24 h
23
6h
32
4h
41
2h
68
20
1h
86
30
30 min
3.2.3
3.2.4
3.2.4
3.2.4
Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online
at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU
are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti
Technical Services for applications and conditions not addressed in the IFU.
HIT-ICE Volume
3.2.5
3.2.6
3.2.7
Drill bit
diameter
in.
Adhesive volume
required
per Inch of
embedment in 3
1/4
5/16
0.055
3/8
7/16
0.095
1/2
9/16
0.133
5/8
11/16
0.184
3/4
13/16
0.232
7/8
24mm
0.272
1-1/16
0.366
1-1/4
1-1/2
0.918
Example:
A HIT-ICE cartridge contains a useable
volume of 18 in3. So, for a 5/8-in. diameter
rod with an embedment of 10 inches:
Rebar
size
Nominal bit1
diameter
in.
Adhesive
volume
required
per Inch of
embedment
in 3
#3
1/2
0.110
#4
5/8
0.146
#5
3/4
0.176
#6
7/8
0.218
#7
0.252
#8
1-1/8
0.299
#9
1-3/8
0.601
#10
1-1/2
0.659
#11
1-3/4
1.037
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 161
Contents
24 Cartridges, 24 Mixers
Description
Notes
MD 1000 Dispenser
Description
Notes
HIT-ICE Cartridge
Qty/Pkg
1
Qty/Pkg
1
1 For ordering information about Hilti anchors, adhesive anchoring dispensers, drilled hole preparation
and other adhesive anchor accessories, see HIT-HY 200 Adhesive Anchor System, Section 3.2.3.5
Ordering Information.
HIT-ICE Mixer
HIT-ICE Cartridge
MD 1000
Dispenser
HIT-ICE Mixer
HIT Filler Tube
HIT-ICE Dispenser
162 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.2.7.1
Product description
Guide specifications
3.2.7.2
Material specifications
3.2.7.3
Technical data
3.2.7.4
Installation instructions
03250
03 16 00 Concrete
anchors
3.2.7.5
Ordering information
03200
03 20 00 Concrete
reinforcing
05050
05 50 00 Metal
fabrications
05120
05 10 00 Structural metal
framing
Related Sections:
Listings/Approvals
ICC-ES (International Code Council)
ESR-2682
ICC-ES (International Code Council)
ESR-3342 URM
City of Los Angeles
Research Report No. 25947 URM only
3.2.3
LEED Credit 4.1-Low Emitting
Materials
The Leadership in Energy and
Environmental Design (LEED ) Green
Building Rating systemTM is the nationally
accepted benchmark for the design,
construction and operation of high
performance green buildings.
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 163
7,252-10,153 psi
50-70 MPa
246,568 psi
1,700 MPa
Water absorption
Electrical resistance
VDE/DIN 0303T3
3-8 %
4.2 x 1011 ohm/in.
164 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Effective
embedment
in. (mm)11
Tensioncr
lb (kN)
Critical
scr
in. (mm)
Rebar
size
3/8
3-3/8
(86)
1,240
(5.5)
1/2
4-1/2
(115)
5/8
3/4
Minimum
smin
in. (mm)
Edge distance10
Critical
ccr
in. (mm)
13.5
(342.9)
0.70
12
(304.8)
0.80
2,035
(9.0)
18
(457.2)
0.70
20
(508)
0.76
5-5/8
(143)
2,840
(12.6)
22.5
(571.5)
0.50
20
(508)
6-3/4
(172)
3,810
(16.9)
27
(685.8)
0.50
20
(508)
4 (102)
Minimum
cmin
in. (mm)
Load
reduction
factor @
cmin12
Load
reduction
factor @ smin6
4 (102)
0.71
0.66
3.2.3
Table 3 - HIT-HY 70 allowable adhesive bond shear loads for threaded rods and reinforcing bars in the face
of grout-filled concrete masonry walls1, 2, 3, 4, 5, 6, 7, 8
Spacing9
Nominal
anchor
diameter
Rebar
size
3/8
Minimum
smin
in. (mm)
Load
reduction
factor @
smin6
Effective
embedment
in. (mm)11
Shear
lb (kN)
Critical
scr
in. (mm)
3-3/8
(86)
850
(3.8)
13.5
(342.9)
1.00
12
(304.8)
0.88
1.00
1/2
4-1/2
(115)
1,495
(6.7)
18
(457.2)
1.00
12
(304.8)
0.49
1.00
5/8
5-5/8
(143)
2,615
(11.6)
22.5
(571.5)
0.50
20
(508)
0.40
0.78
3/4
6-3/4
(172)
4,090
(18.2)
27
(685.8)
0.50
20
(508)
0.26
0.60
4 (102)
Critical
ccr
in. (mm)
Edge distance10
Load reduction factor
@ cmin12
Minimum
Load
Load
cmin
perpendicular
parallel
in. (mm)
to edge
to edge
4 (102)
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units shall be lightweight,
medium-weight or heavy-weight conforming to ASTM C90. Allowable loads are calculated using a safety factor of 5.
2 Anchors may be installed in any location in the face of the masonry wall including cell, web, and mortar joints. Anchors are limited to one per masonry cell.
3 Linear interpolation of load values between minimum spacing (smin) and critical spacing (scr) and between minimum edge distance (cmin) and critical edge distance (ccr)
is permitted.
4 Concrete masonry thickness must be equal to or greater than 1.5 times the anchor embedment depth. EXCEPTION: the 5/8-inch- and the 3/4-inch diameter anchors
(No. 5 and No. 6 bars) may be installed in minimum nominally 8-inch thick concrete masonry.
5 When using the basic load combinations in accordance with IBC Section 1605.3.1, tabulated allowable loads must not be increased for seismic or wind loading.
When using the alternative basic load combinations in IBC Section 1605.3.2 that include seismic or wind loads, tabulated allowable loads may be increased by 33-1/3
percent, or the alternative basic load combinations may be reduced by a factor of 0.75.
6 Allowable loads must be the lesser of the adjusted masonry or bond tabulated values and the steel values given in table 4.
7 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12.
8 For combined loading: (Tapplied / Tallowable)n + (Vapplied / Vallowable)n 1
where n=5/3 for 3/8- and 1/2-inch diameters (No. 3 and No. 4 rebar) and n=1 for 5/8- and 3/4-inch diameters (No. 5 and No. 6 rebar).
9 The critical spacing, scr, is the anchor spacing where full load values may be used. The minimum spacing, smin, is the minimum anchor spacing for which values are
available and installation is recommended. Spacing is measured from the center of one anchor to the center of an adjacent anchor.
10 The critical edge distance, ccr, is the edge distance where full load values may be used. The minimum edge distance, cmin, is the minimum edge distance for which
values are available and installation is recommended. Edge distance is measured from the center of the anchor to the closest edge.
11 Embedment depth is measured from the outside face of the concrete masonry unit.
12 Load reduction factors are multiplicative, both spacing and edge distance load reduction factors must be considered.
Load values for anchors installed at less than scr and ccr must be multiplied by the appropriate load reduction factor based on actual edge distance (c) and spacing (s).
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 165
Shear, lb (kN)
ASTM
A36
ASTM
A307
ASTM
A193 B7
ISO 898
Class 5.8
ASTM F593
CW
304/316
1/4
940
(4.2)
972
(4.3)
2,025
(9.0)
1,175
(5.2)
1,620
(7.2)
485
(2.2)
5/16
1,470
(6.5)
1,520
(6.8)
3,160
(14.1)
1,835
(8.2)
2,530
(11.3)
3/8
2,115
(9.4)
2,185
(9.7)
4,555
(20.3)
2,640
(11.7)
3,755
(16.7)
3,885
(17.3)
8,100
(36.0)
5/8
5,870
(26.1)
6,075
(27.0)
3/4
8,455
(37.6)
8,750
(38.9)
1/2
ASTM A307
ASTM
A193 B7
ISO 898
Class 5.8
ASTM F593
CW
304/316
500
(2.2)
1,040
(4.6)
605
(2.7)
835
(3.7)
756
(3.4)
780
(3.5)
1,630
(7.3)
945
(4.2)
1,300
(5.8)
3,645
(16.2)
1,090
(4.8)
1,125
(5.0)
2,345
(10.4)
1,360
(6.1)
1,875
(8.3)
4,700
(20.9)
6,480
(28.8)
1,935
(8.6)
2,000
(8.9)
4,170
(18.6)
2,420
(10.8)
3,335
(14.8)
12,655
(56.3)
7,340
(32.7)
10,125
(45.0)
3,025
(13.5)
3,130
(13.9)
6,520
(29.0)
3,780
(16.8)
5,215
(23.2)
18,225
(81.1)
10,570
(47.0)
14,580
(64.9)
4,355
(19.4)
4,506
(20.0)
9,388
(41.8)
5,445
(24.2)
7,510
(33.4)
ASTM
A36
1 Allowable load used in the design must be the lesser of bond values and tabulated steel values.
2 The allowable tension and shear values for threaded rods to resist short term loads, such as wind or seismic, must be calculated in accordance with the appropriate
IBC Sections.
3 Allowable steel loads are based on tension and shear stresses equal to 0.33 x Fu and 0.17 x Fu , respectively.
Table 5 - HIT-HY 70 allowable adhesive bond loads for threaded rods and reinforcing bars in the top of grout-filled
concrete masonry walls1, 2, 3, 4, 5, 6
Nominal anchor
diameter or rebar
size
Effective
embedment
in. (mm)
1/2
4-1/2
(114)
5/8
5-5/8
(143)
4-1/2
(114)
5-5/8
(143)
No. 4
No. 5
Edge
distance
in. (mm)7, 8
1-3/4
(44.5)
4
(101.6)
1-3/4
(44.5)
4
(101.6)
1-3/4
Minimum end
distance
in. (mm)
8
(203)
Tension
lb (kN)
1,165
(5.2)
1,625
(7.2)
1,165
(5.2)
1,590
(7.1)
865
(4.0)
980
(4.4)
1 A
ll values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units shall be lightweight,
medium-weight or heavy-weight conforming to ASTM C90. Allowable loads are calculated using a safety factor of 5.
2 When using the basic load combinations in accordance with IBC Section 1605.3.1 or the alternative basic load combinations in IBC Section 1605.3.2. Tabulated
allowable loads must not be increased for seismic or wind loading.
3 One anchor shall be permitted to be installed in each concrete block.
4 Anchors are not permitted to be installed in a head joint, flange or web of the concrete masonry unit.
5 Allowable loads must be the lesser of the adjusted masonry or bond tabulated values and the steel values given in table 4.
6 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12.
7 For combined loading: (Tapplied / Tallowable) + (Vapplied / Vallowable ) 1
8 The tabulated edge distance is measured from the anchor centerline to the edge of the concrete block. See figure 2.
9 Linear interpolation of load values between the two tabulated edge distances is permitted.
hef
End Distance
166 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Tension
lb (kN)
Critical
scr
in. (mm)
3/8-16 UNC
4-3/8
(111)
2,075
(9.2)
17
(431.8)
1/2-13 UNC
5
(127)
2,710
(12.1)
20
(508)
Thread
size
Edge distance10
Minimum
smin
in. (mm)
Load
reduction
factor @ smin6
Critical
ccr
in. (mm)
0.55
12
(304.8)
0.55
20
(508)
4
(102)
Minimum
cmin
in. (mm)
Load
reduction
factor @ cmin12
4
(102)
0.82
0.63
Table 7 - HIT-HY 70 allowable adhesive bond shear loads for HIS-N inserts in the face of grout-filled
concrete masonry walls1, 2, 3, 4, 5, 6, 7,8
Edge distance10
Spacing9
Effective
embedment
in. (mm)11
Shear
lb (kN)
Critical
scr
in. (mm)
3/8-16 UNC
4-3/8
(111)
1,100
(4.9)
17
(431.8)
1/2-13 UNC
5
(127)
2,065
(9.2)
20
(508)
Thread
size
Minimum
smin
in. (mm)
4
(102)
Load
reduction
factor @
smin6
Critical
ccr
in. (mm)
0.74
12
(304.8)
0.71
20
(508)
Minimum,
cmin
in. (mm)
Load
perpendicular
to edge
Load
parallel to
edge
0.72
1.00
0.40
0.87
4
(102)
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units shall be lightweight,
medium-weight or heavy-weight conforming to ASTM C90. Allowable loads are calculated using a safety factor of 5.
2 Anchors may be installed in any location in the face of the masonry wall including cell, web, and mortar joints. Anchors are limited to one per masonry cell.
3 Linear interpolation of load values between minimum spacing (smin) and critical spacing (scr) and between minimum edge distance (cmin) and critical edge distance (ccr)
is permitted.
4 Concrete masonry thickness must be equal to or greater than 1.5 times the anchor embedment depth. Exception: 5/8-and 3/4-in. anchors (No. 5 and No. 6 bars) may
be installed in minimum nominally 8-inch-thick concrete masonry.
5 When using the basic load combinations in accordance with IBC Section 1605.3.1, tabulated allowable loads must not be increased for seismic or wind loading.
When using the alternative basic load combinations in IBC Section 1605.3.2 that include seismic or wind loads, tabulated allowable loads may be increased by 33-1/3
percent, or the alternative basic load combinations may be reduced by a factor of 0.75.
6 Allowable loads must be the lesser of the adjusted masonry or bond tabulated values and the steel values given in table 4.
7 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12.
8 For combined loading: (Tapplied / Tallowable)n + (Vapplied / Vallowable)n 1
where n=5/3 for 3/8- and 1/2-inch diameters (No. 3 and No. 4 rebar) and n=1 for 5/8- and 3/4-inch diameter or No. 5 and No. 6 rebar.
9 The critical spacing, scr, is the anchor spacing where full load values may be used. The minimum spacing, smin, is the minimum anchor spacing for which values are
available and installation is recommended. Spacing is measured from the center of one anchor to the center of an adjacent anchor.
10 The critical edge distance, ccr, is the edge distance where full load values may be used. The minimum edge distance, cmin, is the minimum edge distance for which
values are available and installation is recommended. Edge distance is measured from the center of the anchor to the closest edge.
11 Embedment depth is measured from the outside face of the concrete masonry unit.
12 Load reduction factors are multiplicative, both spacing and edge distance load reduction factors must be considered.
Load values for anchors installed at less than scr and ccr must be multiplied by the appropriate load reduction factor based on actual edge distance (c) and spacing (s).
ho
do
hef
screw
engagement
length
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
c1
A
Installation in
this area for
reduced allowable
load capacity
c2
3.2.3
Adhesive
anchor
1
Installation in
this area for
full allowable
load capacity
4" Minimum
edge distance
Critical edge
distance
(See load tables)
A-A
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 167
Effective
embedment
in. (mm)5
1/4
5/16
3/8
2
(51)
1/2
Tension
lb (kN)6, 7, 8
220
(1.0)
390
(1.7)
390
(1.7)
390
(1.7)
Minimum edge
distance cmin
in. (mm)9
4
(102)
Edge distance6
Load reduction
factor @ cmin
1.00
Shear
lb (kN)6, 7, 8
Critical ccr
in. (mm)
355
(1.6)
630
(2.8)
645
(2.8)
670
(3.0)
4
(101.6)
12
(304.8)
12
(304.8)
12
(304.8)
Minimum cmin
in. (mm)
Load reduction
factor @ cmin
1.00
4
(102)
0.73
0.73
0.73
Table 9 - HIT-HY 70 allowable adhesive bond loads for HIT-IC inserts in the face of hollow concrete masonry units1, 2, 3, 4
Thread
size
Effective
embedment
in. (mm)5
#14 Screw
5/16-18
UNC
3/8-16
UNC
1/2-13
UNC
2
(51)
Tension
lb (kN)6, 7, 8
190
(0.8)
415
(1.8)
480 5
(2.1)
495 5
(2.2)
Minimum edge
distance cmin
in. (mm)9
4
(102)
Edge distance6
Load reduction
factor @ cmin
1.00
Shear
lb (kN) 6, 7, 8
Critical ccr
in. (mm)
235
(1.0)
605
(2.7)
620
(2.8)
620
(2.8)
4
(101.6)
12
(304.8)
12
(304.8)
12
(304.8)
Minimum cmin
in. (mm)
Load reduction
factor @ cmin
1.00
4
(102)
0.80
0.78
0.75
1 All values are for anchors installed in hollow concrete masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units shall be lightweight, medium-weight
or normal-weight conforming to ASTM C90. Allowable loads are calculated using a safety factor of 5.
2 Anchors shall be installed in the face of the ungrouted concrete block wall. A maximum of two anchors for each cell of the hollow ungrouted concrete block is allowed.
3 Anchors are not recognized for resisting earthquake forces. For short-term loading due to wind forces, the allowable loads shall not be increased.
4 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12.
5 Tabulated embedment depth is the length of the plastic HIT-SC screens.
6 Tabulated values are for one anchor installed in the cell of the ungrouted concrete block. Installation in other locations of the the mortars joints, flange or web of the concrete
block is not permitted.
7 The minimum spacing, smin, for which values are available and installation is recommended, is equal to 4 inches. Two anchors installed in adjacent cells may be spaced as
close as 4 inches apart without any load reduction. Two anchors installed in the same cell can be spaced as close as 4 inches apart without any load reduction, except for the
3/8- and 1/2-in. diameter HIT-IC inserts, where a 20% reduction needs to be applied to the allowable tension load.
8 Allowable loads must be the lesser of the adjusted masonry or bond tabulated values above and the steel values given in table 4.
9 The critical edge distance, ccr, is the edge distance where full load values in the Table may be used. The minimum edge distance, cmin, is the minimum edge distance for which
values are available and installation is recommended. Edge distance is measured from the center of the anchor to the closest edge.
ho
do
hef
do
hef
screw
engagement
length
168 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Effective
embedment
in.
(mm)6
1/4
5/16
3/8
Tension
lb (kN)7, 8
Minimum edge
distance cmin
in.
(mm)9
Load
reduction
factor @ cmin
530 (2.4)
3-1/8 (79)
1/2
735 (3.3)
905 (4.0)
(203)
1.00
Edge distance6
Shear
lb
(kN)7, 8
370
(1.6)
595
(2.6)
1,045 (4.7)
905 (4.0)
Critical ccr
in.
(mm)
Minimum cmin
in.
Load reduction
factor @ cmin
(mm)
1.00
12
(304.8)
1.00
(203)
0.76
1,685 (7.5)
0.52
Table 11 - HIT-HY 70 allowable adhesive bond loads for HIT-IC inserts in the face of hollow brick1, 2, 3, 4, 5
Thread
size
Effective
embedment
#14 Screw
in.
(mm)6
(51)
5/16-18 UNC
3/8-16 UNC
3-1/8 (79)
1/2-13 UNC
Minimum edge
distance cmin
Tension
lb
(kN)7, 8
in.
Edge distance6
Shear
lb
(kN)7, 8
170 (0.8)
222
(1.0)
880 (3.9)
650
(2.9)
880 (3.9)
(mm)9
Load
reduction
factor @ cmin
(203)
1.00
1,290 (5.7)
990 (4.4)
Critical ccr
in.
(mm)
Minimum cmin
in.
(mm)
Load reduction
factor @ cmin
1.00
12
(304.8)
1.00
(203)
1,780 (7.9)
0.47
1 All values are for anchors installed in hollow brick masonry with minimum masonry prism strength of 3,000 psi. Hollow brick units shall be conforming to ASTM C652.
Allowable loads are calculated using a safety factor of 5.
2 Anchors shall be installed in the face of the hollow brick masonry wall.
3 Anchors are not recognized for resisting earthquake forces. For short-term loading due to wind forces, the allowable loads shall not be increased.
4 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12.
5 Tabulated embedment depth is limited by the length of the plastic HIT-SC screens.
6 Tabulated values are for one anchor installed in any location of the brick wall including the horizontal and head mortar joints.
7 One anchor shall be permitted to be installed in each brick. Two anchors may be spaced as close as the lesser of 2 bricks or 8 in. apart without any load reduction.
8 Allowable loads must be the lesser of the adjusted masonry or bond tabulated above and the steel values given in table 4.
9 The critical edge distance, ccr, is the edge distance where full load values in the table may be used. The minimum edge distance, cmin, is the minimum edge distance for which
values are available and installation is recommended. Edge distance is measured from the center of the anchor to the closest edge.
Table 12 - HIT-HY 70 allowable adhesive bond loads for threaded rods in multi-wythe solid brick walls1, 2, 3, 4, 5, 6
Nominal anchor
diameter
Effective
embedment7
3/8
1/2
5/8
3/4
Tension
Shear
in.
(mm)
lb
(kN)
lb
(kN)
(152)
895
(4.0)
680
(3.0)
10
(254)
1,325
(5.9)
795
(3.5)
(152)
895
(4.0)
1,075
(4.8)
10
(254)
1,455
(6.5)
1,115
(5.0)
(152)
1,025
(4.6)
1,405
(6.3)
10
(254)
1,955
(8.7)
1,445
(6.4)
(203)
1,575
(7.0)
1,985
(8.8)
13
(330)
2,135
(9.5)
1,985
(8.8)
3.2.3
0.63
Minimum
spacing smin
in.
(mm)
Minimum edge
distance cmin
in.
(mm)
3.2.4
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
16
(406.4)
16
(406.4)
3.2.8
1
2
3
4
All values are based on mortar shear strength of 45 psi or greater. Allowable loads are calculated using a safety factor of 5.
Anchors must be installed in the face of the multi-wythe URM wall. The wall must have a minimum thickness of 13 inches representing 3 wythes of brick..
Tabulated values are for maximum one anchor installed in the center of the brick of the multi-wythe URM wall.
Edge distance, cmin, and spacing, smin, are the minimum distances for which values are available and installation is recommended. Edge distance is measured from the center of
the anchor to the closest edge. Spacing is measured from the center of one anchor to the center of an adjacent anchor.
5 Allowable loads must be the lesser of the adjusted masonry or bond tabulated values and the steel values given in table 4.
6 Tabulated allowable loads shall be adjusted for increased base material temperatures in accordance with figure 12.
7 Tabulated embedment depth is limited by the length of the plastic HIT-SC screens.
ho
do
hef
ho
do
hef
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 169
Bar
size
4
5
6
Embedment
in.
(mm)
Tension
lb
(kN)
8
(203)
13
(330)
Configuration B 22 1/2 combination anchor
Minimum wall thickness
Tension
Embedment
in.
in.
(mm)
lb
(kN)
Within 1 inch of the
13
(330)
1,200
(5.3)
opposite wall surface
Shear 4
lb
(kN)
500
(2.2)
750
(3.3)
1,000
(4.5)
lb
Shear 4
1,000
(kN)
(4.5)
1 Allowable load values are applicable only to anchors where in-place shear tests indicate minimum mortar strength of 50 psi.
2 Allowable loads are computed in accordance with ICC-ES AC60 (2010) and IBC
3 No increase for short-term loading is permitted, such as loading induced by wind or earthquake.
4 Anchors must be tested in accordance with the requirements of IEBC and UCBC.
Table 14 - HIT-HY 70 allowable adhesive bond loads for threaded rods in hollow core concrete panels1, 4, 5, 6
Nominal anchor
diameter
in.
3/8
Effective
embedment
in.
(mm) 2
2
(50.8)
Minimum
concrete thickness
in.
(mm) 3
1-3/8
(34.9)
lb
450
Tension
(kN)
(2.0)
lb
560
Shear
(kN)
(2.5)
1 A
ll values are for anchor installed in hollow core concrete with minimum compressive strength of 7,000 psi. Due to variations in materials and dimensional
configurations, on-site testing is required to determine the actual performance of the anchor. Allowable loads are calculated using a safety factor of 5.
2 Tabulated embedment depth is limited by the length of the plastic HIT-SC 16x50 mm screens. See figure 11.
3 The required concrete thickness is the thickness for which values are available and installation is recommended. Anchors shall be installed along the centerline of the
hollow core or along the line of minimum thickness. Verify these requirements with the hollow core plank supplier before installation. The required thickness is measured
from the inner to the outer side of the hollow core panel. In case of deviation from the outlined requirements, field testing is required. See figure 11.
4 Tabulated allowable loads must be the lesser of the adjusted concrete or bond values tabulated and the steel values in table 4.
5 Tabulated allowable bond loads shall be adjusted for increased base material temperatures in accordance with figure 12.
6 The required adhesive gel and cure times shall be identical to the values adopted for masonry.
170 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
68
Technical Services for applications and conditions not addressed in the IFU.
-5 ... 0
1 ... 5
6 ... 10
11 ... 20
21 ... 30
31 ... 40
23 32
33 41
42 50
51 68
69 86
87 104
10
10
7
4
2
1
6
4
2.5
1.5
30
20
min
min
min
min
min
min
69 86
21 ... 30
41
42 50
51 68
69 86
87 104
5
6 ... 10
11 ... 20
21 ... 30
31 ... 40
h
h
h
h
min
min
11 ... 20
21 ... 30
31 ... 40
10
7
4
2
1
min
98%
min
min
min
min
4
2.5
1.5
30
20
h
h
h
min
min
10
7
4
2
1
min
min
min
min
min
30 min
20 min
4
2.5
1.5
30
20
h
h
h
min
min
3.2.3
3.2.4
3.2.4
3.2.4
80%
3.2.5
74%
3.2.6
2 min
... 40
1 brick
min
8716
104
Table
- Gel and31full-cure
time in
56%
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 171
HDE 500
Battery
Dispenser
HIT-HY 70
(11.1 fl oz/330 ml)
HDM 500
Manual
Dispenser
HIT-HY 70
(16.9 fl oz/500 ml)
Description
P3500
Dispenser
Adhesive Pack
Holder
Qty of Foil
Packs
Package Contents
Includes (1) foil pack with (1) mixer and 3/8-in. filler tube per pack
Includes (1) master carton containing (25) foil packs with (1) mixer and 3/8-in. filler tube per pack
Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8-in. filler tube per pack and (1)
HDM 500 manual dispenser
Includes (1) master carton containing (20) foil packs with (1) mixer and 3/8-in. filler tube per pack
Includes 2 master cartons containing (20) foil packs each with (1) mixer and 3/8-in. filler tube per pack
and (1) HDM 500 manual dispenser
40
1
25
25
20
Mesh Sleeve
Embedment, in.
Qty
20
1/2
25
40
HAS B 1/4 x 3
20
1/2
(1) SC 12x50
25
40
3-1/8
20
1/2
(1) SC 12x85
16
26
20
5/8
(1) SC 16x50
16
26
3-1/8
20
5/8
(1) SC 16x85
12
10
5/8
(1) SC 16x50
16
26
3-1/8
10
5/8
(1) SC 16x85
12
10
11/16
(1) SC 18x50
15
3-1/8
10
11/16
(1) SC 18x85
172 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Qty
Actual
Dia., in.
Length,
in.
Bit Dia.
20
0.47
1.97
1/2
20
0.47
3.35
1/2
20
0.63
1.97
5/8
20
0.63
3.35
5/8
20
0.71
1.97
11/16
11/16
20
0.71
3.35
20
0.87
1.97
7/8
10
0.87
3.35
7/8
20
1.02
4.92
20
1.02
7.87
Qty
Bit Dia.,
in.
Threads
per inch
10
5/8
18
10
5/8
18
10
7/8
16
10
7/8
16
Description
10
7/8
13
10
7/8
13
20
1/2
3.2.3
3.2.4
Mesh Sleeve
Embedment, in.
Qty
20
5/8
(2) SC 16x50
15
24
6-3/4
10
5/8
(2) SC 16x85
14
10
10
5/8
(3) SC 16x85
6-3/4
10
11/16
(2) SC 18x85
11
10
10
11/16
(3) SC 18x85
6-3/4
20
7/8
(2) SC 22x85
10
10
7/8
(3) SC 22x85
HAS-E 3/4 x 10
10
(1) SC 26x200
HAS-E 3/4 x 14
13
10
(1) SC 26x200,
(1) SC 26x125
HAS-E 3/4 x 17
15-3/4
10
(2) SC 26x200
HAS-E 3/4 x 19
18
10
(2) SC 26x125,
(1) SC 26 x 200
HAS-E 3/4 x 25
23-1/2
10
(3) SC 26x200
HAS-E 1/2 x 8
HAS-E 1/2 x 12
HAS-E 5/8 x 8
HAS-E 5/8 x 12
3.2.4
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
Mesh Sleeve
Embedment, in.
Qty
10
5/8
(1) SC 16x50
16
26
3-1/4
10
5/8
(1) SC 16x85
12
15
10
7/8
(1) SC 22x50
3-1/4
10
7/8
(1) SC 22x85
10
7/8
(1) SC 22x50
15
3-1/4
10
7/8
(1) SC 22x85
Cleaning accessories
Round Brush Size
use with HIT-RBH handle
Qty
1/2
HIT-RB 1/2
5/8
HIT-RB 5/8
HIT-RB 11/16
HIT-RB 7/8
HIT-RB 1
Hole Diameter
11/16
7/8
1
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 173
Product description
3.2.8.2
Material specifications
3.2.8.3
Technical data
3.2.8.4
Installation instructions
3.2.8.5
Ordering information
Listings/Approvals
European Technical approval
ETA-05/0255
ETA-05/0256
ETA-05/0257
Product features
174 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.2.3
3.2.3
3.2.4
AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18.22.1 Type A plain.
HAS-R 316 stainless steel specifications
3.2.3
3/8-, 1/2- and 5/8-in. rods manufactured from AISI Type 316 stainless steel with a minimum tensile strength of 100 ksi (689
MPa) and a minimum yield strength of 65 ksi (448 MPa).
3.2.5
3/4-, 1- and 1 1/4-in. rods are manufactured from AISI Type 316 stainless steel conforming to ASTM F593 Condition CW.
AISI Type 304 stainless steel nuts conform to ASTM F594.
AISI Type 304 stainless steel washers conform to ASTM A240 and ANSI B18.22.1 Type A plain.
3.2.6
3.2.7
3.2.8
1/2-, 5/8- and 3/4-in. HIS-N is manufactured from 11MnPb30+C carbon steel conforming to DIN 10277-3 with a minimum tensile strength of 66.7 ksi (460 MPa) and a minimum yield strength of 54.4 ksi (375 MPa).
HIS-RN is manufactured from X5CrNiMo 17122 K700 stainless steel conforming to DIN EN 10088-3 with a minimum tensile
strength of 101.5 ksi (700 MPa) and a minimum yield strength of 50.8 ksi (350 MPa).
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 175
Symbol
Units
do
in.
in.
(mm)
(90)
hef,std
Installation torque
Tinst
hmin
3/8
1/2
5/8
3/4
7/8
1-1/4
7/16
9/16
11/16
3-1/2
4-1/4
7/8
1-1/8
1-38
6-5/8
6-5/8
8-1/4
(110)
(125)
(170)
12
(170)
(210)
(305)
ft-lb
18
30
75
150
175
235
400
(Nm)
(24)
(41)
(102)
(203)
(237)
(319)
(540)
in.
hef+2
hef+2 1/4
hef+3
(mm)
hef+51
hef+57
hef+76
Table 2 - HIS-N and HIS-RN installation specifications with HVU adhesive anchoring system
Setting information
Symbol
Units
HVU capsule
Thread size
3/8-16 UNC
1/2-13 UNC
5/8-11 UNC
3/4-10 UNC
1/2x4-1/4
5/8x5
7/8x6-5/8
1x8-1/4
in.
0.65
0.81
1.00
1.09
do
in.
11/16
7/8
1-1/8
1-1/4
Effective embedment
hef
in.
4-3/8
6-5/8
8-1/4
(mm)
(110)
(125)
(170)
(210)
in.
3/8
1/2
5/8
3/4
in.
15/16
1-3/16
1-1/2
1-7/8
minimum
Bolt engagement
maximum
hs
Installation torque
Tinst
Concrete thickness
hmin
ft-lb
18
30
75
150
(Nm)
(24)
(41)
(102)
(203)
in.
6-3/8
7-1/2
10
12-3/8
(mm)
(162)
(191)
(254)
(314)
Symbol
Units
do
hef,std
Rebar size
#4
#5
#6
#7
#8
in.
5/8
3/4
7/8
1-1/8
in.
4-1/4
6-5/8
6-5/8
8-1/4
(mm)
(110)
(125)
(170)
(170)
(210)
1 Rebar diameters may vary. The rebar must be at least 4 inches longer than the embedment to accomodate the setting equipment.
( ) ( )
Nd
N rec
5/3
Vd
Vrec
5/3
1.0
176 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Embed.
depth3
in.
3-1/2
(90)
3/8
5-1/4
(133)
7
(178)
4-1/4
(110)
1/2
6-3/8
(162)
8-1/2
(216)
5
(125)
5/8
7-1/2
(184)
10
(254)
6-5/8
(170)
3/4
10
(254)
13-1/4
(337)
6-5/8
(170)
7/8
10
(254)
13-1/4
(337)
8-1/4
(210)
12-3/8
(314)
16-1/2
(419)
12
(305)
1-1/4
15
(381)
18
(457)
Adhesive
capsule(s)
required
(1) 3/8 x 3-1/2
(2) 3/8 x 3-1/2
(2) 3/8 x 3-1/2
(1) 1/2 x 4-1/4
(1) 1/2 x 4-1/4 &
(1) 3/8 x 3-1/2
(2) 1/2 x 4-1/4
(1) 5/8 x 5
(1) 5/8 x 5 &
(1) 1/2 x 4-1/4
(2) 5/8 x 5
(1) 3/4 x 6-5/8
(1) 3/4 x 6-5/8 &
(1) 1/2 x 4-1/4
(2) 3/4 x 6-5/8
(1) 7/8 x 6-5/8
(2) 3/4 x 6-5/8
(2) 7/8 x 6-5/8
Tensile
Shear
Tensile
Shear
'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi 'c = 2000 psi 'c = 4000 psi
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
2,085
2,595
3,335
4,710
8,345
10,380
10,000
(9.3)
(11.5)
(14.8)
(21.0)
(37.1)
(46.2)
(44.5)
14,120
(62.8)
2,325
4,185
6,120
8,655
9,295
16,730
18,360
25,960
(10.3)
(18.6)
(27.2)
(38.5)
(41.3)
(74.4)
(81.7)
(115.5)
4,405
4,895
9,420
13,330
17,630
19,590
28,260
39,980
(19.6)
(21.8)
(41.9)
(59.3)
(78.4)
(87.1)
(125.7)
(177.8)
3,250
4,735
5,450
7,280
12,990
18,940
15,440
21,840
(14.5)
(21.1)
(24.2)
(32.4)
(57.8)
(84.2)
(68.7)
(97.1)
4,890
5,455
9,455
13,375
19,565
21,815
28,360
40,120
(21.8)
(24.3)
(42.1)
(59.5)
(87.0)
(97.0)
(126.2)
(178.5)
6,700
7,545
14,560
20,590
26,810
30,190
43,680
61,760
(29.8)
(33.6)
(64.8)
(91.6)
(119.3)
(134.3)
(194.3)
(274.7)
3,970
5,245
7,350
10,390
15,890
20,970
22,040
31,160
(17.7)
(23.3)
(32.7)
(46.2)
(70.7)
(93.3)
(98.0)
(138.6)
5,770
10,465
13,495
19,080
23,080
41,865
40,480
57,240
(25.7)
(46.6)
(60.0)
(84.9)
(102.7)
(186.2)
(180.1)
(254.6)
11,700
12,835
20,775
29,375
46,795
51,340
62,320
88,120
(52.0)
(57.1)
(92.4)
(130.7)
(208.2)
(228.4)
(277.2)
(392.0)
6,080
8,615
12,270
17,355
24,330
34,470
36,800
52,060
(27.0)
(38.3)
(54.6)
(77.2)
(108.2)
(153.3)
(163.7)
(231.6)
9,110
14,835
22,755
32,180
36,445
59,350
68,260
96,540
(40.5)
(66.0)
(101.2)
(143.1)
(162.1)
(264.0)
(303.6)
(429.4)
15,220
15,310
34,700
49,080
60,875
61,230
104,100
147,240
(67.7)
(68.1)
(154.4)
(218.3)
(270.8)
(272.4)
(463.1)
(655.0)
7,145
9,130
13,110
18,535
28,580
36,525
39,320
55,600
(31.8)
(40.6)
(58.3)
(82.4)
(127.1)
(162.5)
(174.9)
(247.3)
10,475
18,970
24,575
34,755
41,905
75,870
73,720
104,260
(46.6)
(84.4)
(109.3)
(154.6)
(186.4)
(337.5)
(327.9)
(463.8)
16,475
23,055
34,780
53,010
65,895
92,220
112,440
159,020
(73.3)
(102.6)
(154.7)
(235.8)
(293.1)
(410.2)
(500.2)
(707.4)
8,640
13,425
19,690
27,840
34,560
53,695
59,060
83,520
(38.4)
(59.7)
(87.6)
(123.8)
(153.7)
(238.8)
(262.7)
(371.5)
14,665
23,450
36,170
51,150
58,665
93,800
108,500
153,440
(65.2)
(104.3)
(160.9)
(227.5)
(261.0)
(417.2)
(482.6)
(682.5)
26,645
30,805
55,690
78,750
106,580
123,220
167,060
236,240
(118.5)
(137.0)
(247.7)
(350.3)
(474.1)
(548.1)
(743.1)
(1050.8)
19,175
23,920
38,615
54,610
76,740
95,680
115,840
163,820
(85.3)
(106.4)
(171.8)
(242.9)
(341.4)
(425.6)
(515.3)
(728.7)
24,750
26,855
53,960
76,315
99,000
107,420
161,880
228,940
(110.1)
(119.5)
(240.0)
(339.5)
(440.4)
(477.8)
(720.1)
(1018.4)
29,535
37,920
70,935
100,320
118,140
151,680
212,800
300,960
(131.4)
(168.7)
(315.5)
(446.2)
(525.5)
(674.7)
(946.6)
(1338.7)
(1) 1 x 8-1/4
(2) 7/8 x 6-5/8
(2) 1 x 8-1/4
(1) 1-1/4 x 12
3.2.3
3.2.3
3.2.4
3.2.3
3.2.5
3.2.6
3.2.7
3.2.8
1 Influence factors for spacing and/or edge distance are applied to concrete/bond values above, and then compared to the steel value.
The lesser of the values is to be used for the design.
2 Average ultimate concrete shear capacity based on Strength Design method.
3 Contact Hilti for the use of alternate embedment other than those tested and listed above.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 177
Nominal
anchor
diameter
HAS Super
ASTM A193 B7
HAS-E
ISO 898 Class 5.8
HAS SS
AISI 304/316 SS
Tensile
lb (kN)
Shear
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
3/8
2,640
(11.7)
1,360
(6.0)
4,555
(20.3)
2,345
(10.4)
3,645
(16.2)
1,875
(8.3)
1/2
4,700
(20.9)
2,420
(10.8)
8,100
(36.0)
4,170
(18.5)
6,480
(28.8)
3,335
(14.8)
5/8
7,340
(32.7)
3,780
(16.8)
12,655
(56.3)
6,520
(29.0)
10,125
(45.0)
5,215
(23.2)
3/4
10,570
(47.0)
5,445
(24.2)
18,225
(81.1)
9,390
(41.8)
12,390
(55.1)
6,385
(28.4)
7/8
14,385
(64.0)
7,410
(33.0)
24,805
(110.3)
12,780
(56.9)
16,865
(75.0)
8,690
(38.6)
18,790
(83.6)
9,680
(43.0)
32,400
(144.1)
16,690
(74.2)
22,030
(98.0)
11,350
(50.5)
1-1/4
29,360
(130.6)
15,125
(67.3)
50,620
(225.2)
26,080
(116.0)
34,425
(153.1)
17,735
(78.9)
Table 6 - Ultimate steel strength for carbon steel and stainless steel HAS rods1
Nominal
anchor
diameter
HAS Super
ASTM A193 B7
HAS-E
ISO 898 Class 5.8
HAS SS
AISI 304/316 SS
Yield
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Yield
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
Yield
lb (kN)
Tensile
lb (kN)
Shear
lb (kN)
3/8
4,495
(20.0)
6,005
(26.7)
3,605
(16.0)
8,135
(36.2)
10,350
(43.4)
6,210
(27.6)
5,035
(22.4)
8,280
(36.8)
4,970
(22.1)
1/2
8,230
(36.6)
10,675
(47.5)
6,405
(28.5)
14,900
(66.3)
18,405
(79.0)
11,040
(49.1)
9,225
(41.0)
14,720
(65.5)
8,835
(39.3)
5/8
13,110
(58.3)
16,680
(74.2)
10,010
(44.5)
23,730
(105.6)
28,760
(125.7)
17,260
(76.8)
14,690
(65.3)
23,010
(102.4)
13,805
(61.4)
3/4
19,400
(86.3)
24,020
(106.9)
14,415
(64.1)
35,120
(156.2)
41,420
(185.7)
24,850
(110.5)
15,050
(66.9)
28,165
(125.3)
16,800
(75.2)
7/8
26,780
(119.1)
32,695
(145.4)
19,620
(87.3)
48,480
(215.7)
56,370
(256.9)
33,825
(150.5)
20,775
(92.4)
38,335
(170.5)
23,000
(102.3)
35,130
(156.3)
42,705
(190.0)
25,625
(114.0)
63,600
(282.9)
73,630
(337.0)
44,180
(196.5)
27,255
(121.2)
50,070
(222.7)
30,040
(133.6)
1-1/4
56,210
(250.0)
66,730
(296.8)
40,035
(178.1)
101,755
(452.6)
115,050
(511.8)
69,030
(307.1)
43,610
(194.0)
78,235
(348.0)
46,940
(208.8)
1 Steel strength as defined in AISC Manual of Steel Construction 2nd Ed. (LRFD):
Yield = Fy x tensile stress area
178 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Thread
size
3/8-16
UNC
1/2-13
UNC
Embed.
depth
in.
4-3/8
(110)
5
(127)
5/8-11
UNC
6-5/8
3/4-10
UNC
8-1/4
(168)
(210)
Adhesive
capsule(s)
required
ASTM F593
stainless steel
Tensile
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
3,180
(14.1)
4,370
(19.4)
2,250
(10.0)
3,645
(16.2)
1,875
(8.3)
(1) 5/8 x 5
4,570
(20.3)
7,775
(34.6)
4,005
(17.8)
6,480
(28.8)
3,335
(14.8)
7,460
(33.2)
12,150
(54.0)
6,260
(27.8)
10,125
(45.0)
5,215
(23.2)
(1) 1 x 8-1/4
9,165
(40.8)
17,495
(77.8)
9,010
(40.1)
12,395
(55.1)
6,385
(28.4)
3.2.3
Table 8 - HVU ultimate bond or concrete capacity and steel strength for HIS-N and HIS-RN inserts1,2
HVU ultimate
bond/concrete capacity2
Thread
size
3/8-16
UNC
1/2-13
UNC
Embed.
depth
in.
4-3/8
(110)
5
(127)
5/8-11
UNC
6-5/8
3/4-10
UNC
8-1/4
(168)
(210)
Adhesive
capsule(s)
required
3.2.3
ASTM F593
stainless steel
3.2.4
Tensile
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
Tensile1
lb (kN)
Shear1
lb (kN)
12,715
(56.6)
9,935
(44.2)
5,960
(26.5)
8,280
(36.8)
4,970
(22.1)
3.2.3
(1) 5/8 x 5
18,275
(81.3)
17,665
(78.6)
10,600
(47.2)
14,720
(65.5)
8,835
(39.3)
29,840
(132.7)
27,610
(122.8)
16,565
(73.7)
23,010
(102.4)
13,805
(61.4)
3.2.5
36,660
(163.1)
39,760
(176.9)
23,855
(106.1)
28,165
(125.3)
16,900
(75.1)
1 Use lower value of either bond/concrete capacity or steel strength. Minimum concrete compressive strength f'c is 2,000 psi.
2 Steel values in accordance with AISC
ASTM A325 bolts
Fy = 92 ksi , Fu = 120 ksi
ASTM F593 (AISI 304/316) Fy = 65 ksi, Fu = 100 ksi for 3/8 thru 5/8
Fy = 45 ksi, Fu = 85 ksi for 3/4
Allowable load values
3.2.6
3.2.7
3.2.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 179
Rebar size
Embedment
depth
in.
4-1/4
(108)
#4
6-3/8
(162)
8-1/2
(216)
5
(127)
#5
7-1/2
(184)
10
(254)
6-5/8
(168)
#6
10
(254)
13-1/4
(337)
6-5/8
(168)
#7
10
(254)
13-1/4
(337)
8-1/4
(210)
#8
12-3/8
(314)
16-1/2
(419)
Adhesive
capsule(s)
required
9,680
10,980
12,270
14,850
(43.1)
(48.8)
(54.6)
(66.1)
14,520
16,460
18,400
22,280
(64.6)
(73.2)
(81.9)
(99.1)
19,360
21,950
24,530
29,710
(86.1)
(97.6)
(109.1)
(132.2)
15,000
16,920
18,830
2,2650
(66.7)
(75.3)
(83.8)
(100.8)
22,490
25,370
28,240
33,980
(100.4)
(112.9)
(125.6)
(151.1)
29,990
33,820
37,650
45,310
(133.4)
(150.4)
(167.5)
(201.5)
21,020
24,250
27,470
33,930
(93.5)
(107.9)
(122.2)
(150.9)
31,530
36,370
41,210
50,890
(140.3)
(161.8)
(183.3)
(226.4)
42,040
48,500
54,950
67,850
(187.0)
(215.7)
(244.4)
(301.8)
23,650
27,280
30,910
38,170
(105.2)
(121.3)
(137.5)
(169.8)
35,470
40,920
46,360
57,250
(157.8)
(182.0)
(206.2)
(254.7)
47,300
54,560
61,810
76,330
(210.4)
(242.7)
(274.9)
(339.5)
35,640
40,500
45,360
55,080
(158.5)
(180.2)
(201.8)
(245.0)
53,460
60,750
68,040
82,610
(237.8)
(270.2)
(302.7)
(367.5)
71,270
80,990
90,710
110,150
(317.0)
(360.3)
(403.5)
(490.0)
Yield
strength
lb (kN)
Tensile
strength
lb (kN)
12,000
(53.4)
18,000
(80.1)
18,600
(82.7)
27,900
(124.1)
26,400
(117.4)
39,600
(176.1)
36,000
(160.1)
54,000
(240.2)
47,400
(210.8)
71,100
(316.3)
180 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Actual spacing
Actual embedment
0.5 hef
1.5 hef
c
hef
cmin
ccr
ll
scr
1.5
Shear &
Tension
ccr
1.5
)
smin
1.0
r(
0.5
3.2.3
c
hef
ea
s
hef
She
ar
Sh
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3(s/hef) + 0.55
for scr>s>smin
ccr
2.0
1.0
=
=
=
=
=
=
=
cmin
0.5
.6
.2
.4
.8
1.0
Anchor Spacing Adjustment Factor
(fA)
3.2.3
3.2.4
.2
.6
.4
.8
1.0
3.2.3
3.2.5
3/8-in. diameter
Spacing
tension/shear
A
Embedment
Depth, in. 3-1/2 5-1/4
Ten
=
=
=
=
sio
s
hef
smin
scr
(II)
1-3/4
2
2-5/8
3
3-1/2
4
4-1/2
5-1/4
6
7
7-7/8
8-1/2
9
10
10-1/2
12
13
14
0.70
0.72
0.78
0.81
0.85
0.89
0.94
1.00
0.70
0.72
0.75
0.78
0.81
0.85
0.89
0.95
1.00
0.70
0.72
0.74
0.78
0.81
0.85
0.89
0.89
0.91
0.94
0.96
0.98
1.00
Edge distance
tension
RN
3-1/2 5-1/4
0.60
0.63
0.70
0.74
0.80
0.86
0.91
1.00
0.60
0.63
0.67
0.70
0.74
0.80
0.86
0.93
1.00
0.60
0.63
0.66
0.70
0.74
0.80
0.85
0.86
0.89
0.91
0.94
0.97
1.00
( toward edge)
RV1
3-1/2 5-1/4
0.18
0.22
0.32
0.37
0.45
0.53
0.60
0.72
0.84
1.00
0.18
0.22
0.27
0.32
0.37
0.45
0.53
0.63
0.72
0.78
0.84
0.94
1.00
0.18
0.22
0.26
0.32
0.37
0.45
0.52
0.57
0.60
0.68
0.72
0.84
0.91
1.00
3.2.7
RV2
3-1/2 5-1/4
0.46
0.49
0.55
0.59
0.64
0.69
0.74
0.82
0.90
1.00
0.46
0.49
0.52
0.55
0.59
0.64
0.69
0.76
0.82
0.86
0.90
0.97
1.00
3.2.6
3.2.8
0.46
0.49
0.51
0.55
0.59
0.64
0.69
0.72
0.74
0.79
0.82
0.90
0.95
1.00
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 181
Embedment
4-1/4
depth, in.
Spacing
tension/shear
A
Adjustment
factor
2-1/8
3
3-3/16
3-1/2
4
4-1/4
5
5-1/2
6
6-3/8
7
8
8-1/2
9
9-9/16
10
10-1/2
12
12-3/4
14
16
17
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3 (s/hef) + 0.55
for scr>s>smin
1/2-in. diameter
0.70
0.76
0.78
0.80
0.83
0.85
0.90
0.94
0.97
1.00
6-3/8
8-1/2
0.70
0.71
0.74
0.75
0.79
0.81
0.83
0.85
0.88
0.93
0.95
0.97
1.00
0.70
0.73
0.74
0.76
0.78
0.80
0.83
0.85
0.87
0.89
0.90
0.92
0.97
1.00
Edge distance
tension
RN
4-1/4
0.60
0.68
0.70
0.73
0.78
0.80
0.87
0.92
0.96
1.00
6-3/8
8-1/2
0.60
0.62
0.65
0.67
0.71
0.75
0.78
0.80
0.84
0.90
0.93
0.96
1.00
(II to or away
from edge)
( toward edge)
RV1
4-1/4
0.60
0.64
0.66
0.68
0.70
0.73
0.78
0.80
0.82
0.85
0.87
0.89
0.96
1.00
0.18
0.29
0.32
0.35
0.42
0.45
0.55
0.61
0.67
0.72
0.80
0.93
1.00
6-3/8
0.18
0.21
0.25
0.27
0.33
0.38
0.42
0.45
0.50
0.59
0.63
0.67
0.72
0.76
0.80
0.93
1.00
RV2
8-1/2
4-1/4
0.46
0.53
0.55
0.58
0.62
0.64
0.70
0.75
0.79
0.82
0.87
0.96
1.00
0.18
0.23
0.26
0.29
0.32
0.35
0.42
0.45
0.48
0.52
0.55
0.58
0.67
0.72
0.80
0.93
1.00
6-3/8
0.46
0.48
0.51
0.52
0.56
0.59
0.62
0.64
0.68
0.73
0.76
0.79
0.82
0.84
0.87
0.96
1.00
8-1/2
0.46
0.49
0.51
0.53
0.55
0.58
0.62
0.64
0.66
0.69
0.70
0.72
0.79
0.82
0.87
0.96
1.00
Table 12 - HVU load adjustment factors for 5/8-in. and 3/4-in. diameter anchors
Anchor
diameter
Adjustment
factor
Embedment
depth, in.
2-1/2
3-5/16
3-3/4
4
4-1/2
5
5-1/2
6
6-5/8
7
7-1/2
8
9
9-15/16
10
11-1/4
12
13
13-1/4
15
18
20
22
24
26-1/2
5/8-in. diameter
Spacing
tension/shear
A
5
0.70
0.75
0.78
0.79
0.82
0.85
0.88
0.91
0.95
0.97
1.00
7-1/2
0.70
0.71
0.73
0.75
0.77
0.79
0.82
0.83
0.85
0.87
0.91
0.95
0.95
1.00
10
0.70
0.72
0.73
0.75
0.76
0.78
0.79
0.82
0.85
0.85
0.89
0.91
0.94
0.95
1.00
Edge distance
tension
RN
5
0.60
0.67
0.70
0.72
0.76
0.80
0.84
0.88
0.93
0.96
1.00
7-1/2
0.60
0.61
0.64
0.67
0.69
0.72
0.75
0.77
0.80
0.83
0.88
0.93
0.93
1.00
10
0.60
0.62
0.64
0.67
0.68
0.70
0.72
0.76
0.80
0.80
0.85
0.88
0.92
0.93
1.00
3/4-in. diameter
Edge distance
shear
Edge distance
shear
(II to or away
from edge)
( toward edge)
RV1
5
0.18
0.27
0.32
0.34
0.40
0.45
0.50
0.56
0.63
0.67
0.72
0.77
0.88
0.98
1.00
7-1/2
0.18
0.20
0.23
0.27
0.31
0.34
0.39
0.41
0.45
0.49
0.56
0.63
0.63
0.72
0.77
0.85
0.86
1.00
10
0.18
0.21
0.23
0.27
0.29
0.32
0.34
0.40
0.45
0.45
0.52
0.56
0.61
0.63
0.72
0.88
1.00
RV2
5
0.46
0.52
0.55
0.57
0.60
0.64
0.68
0.71
0.76
0.78
0.82
0.86
0.93
1.00
7-1/2
0.46
0.47
0.50
0.52
0.54
0.57
0.60
0.62
0.64
0.66
0.71
0.76
0.76
0.82
0.86
0.90
0.92
1.00
10
0.46
0.48
0.50
0.52
0.53
0.55
0.57
0.60
0.64
0.64
0.69
0.71
0.75
0.76
0.82
0.93
1.00
Spacing
tension/shear
A
Edge distance
tension
RN
Edge distance
shear
( toward edge)
RV1
Edge distance
shear
(II to or away
from edge)
RV2
0.70
0.72
0.73
0.75
0.76
0.78
0.79
0.82
0.85
0.85
0.89
0.91
0.94
0.95
1.00
0.70
0.71
0.72
0.73
0.75
0.78
0.78
0.80
0.82
0.84
0.85
0.89
0.96
1.00
0.60
0.63
0.64
0.67
0.70
0.73
0.76
0.80
0.82
0.85
0.88
0.94
1.00
0.60
0.62
0.64
0.67
0.68
0.70
0.72
0.76
0.80
0.80
0.85
0.88
0.92
0.93
1.00
0.60
0.61
0.63
0.64
0.67
0.70
0.70
0.74
0.76
0.79
0.80
0.85
0.94
1.00
0.18
0.22
0.24
0.28
0.32
0.36
0.40
0.45
0.48
0.52
0.56
0.64
0.72
0.73
0.83
0.89
0.97
1.00
0.18
0.21
0.23
0.27
0.29
0.32
0.34
0.40
0.45
0.45
0.52
0.56
0.61
0.63
0.72
0.88
1.00
0.18
0.20
0.22
0.24
0.28
0.32
0.32
0.37
0.40
0.44
0.45
0.52
0.64
0.73
0.81
0.89
1.00
0.46
0.48
0.50
0.52
0.55
0.58
0.61
0.64
0.66
0.69
0.71
0.77
0.82
0.82
0.89
0.93
0.99
1.00
0.46
0.48
0.50
0.52
0.53
0.55
0.57
0.60
0.64
0.64
0.69
0.71
0.75
0.76
0.82
0.93
1.00
0.46
0.47
0.48
0.50
0.52
0.55
0.55
0.59
0.61
0.63
0.64
0.69
0.77
0.82
0.88
0.93
1.00
182 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing tension/shear
smin = 0.5 hef
scr = 1.5 hef
A = 0.3(s/hef) + 0.55
for scr>s>smin
Anchor
diameter
7/8-in. diameter
Adjustment
factor
tension/shear
0.70
0.73
0.75
0.78
0.82
0.85
0.87
0.91
0.96
1.00
10
0.70
0.73
0.75
0.76
0.79
0.82
0.85
0.85
0.88
0.91
0.94
0.95
0.97
1.00
Edge distance
tension
Embedment
6-5/8
depth, in.
3-5/16
4
4-1/2
5
6
6-5/8
7
8
9
9-15/16
10
11
12
13
13-1/4
14
15
16
18
20
22
24
26-1/2
Spacing
RN
13-1/4 6-5/8
0.60
0.64
0.67
0.70
0.76
0.80
0.82
0.88
0.94
1.00
0.70
0.71
0.73
0.75
0.78
0.78
0.80
0.82
0.84
0.85
0.87
0.89
0.91
0.96
1.00
10
0.60
0.64
0.67
0.68
0.72
0.76
0.80
0.80
0.84
0.88
0.92
0.93
0.96
1.00
( toward edge)
(II to or away
from edge)
10
10
RV1
13 1/4 6-5/8
0.18
0.24
0.28
0.32
0.40
0.45
0.48
0.56
0.64
0.72
0.73
0.81
0.89
0.97
1.00
0.60
0.61
0.64
0.67
0.70
0.70
0.73
0.76
0.79
0.80
0.82
0.85
0.88
0.94
1.00
0.18
0.23
0.27
0.29
0.34
0.40
0.45
0.45
0.50
0.56
0.61
0.63
0.67
0.72
0.77
0.88
1.00
RV2
13-1/4 6-5/8
0.18
0.20
0.24
0.28
0.32
0.32
0.36
0.40
0.44
0.45
0.48
0.52
0.56
0.64
0.73
0.81
0.89
1.00
0.46
0.50
0.52
0.55
0.61
0.64
0.66
0.71
0.77
0.82
0.82
0.88
0.93
0.99
1.00
13-1/4
0.46
0.50
0.52
0.53
0.57
0.60
0.64
0.64
0.68
0.71
0.75
0.76
0.78
0.82
0.86
0.93
1.00
0.46
0.47
0.50
0.52
0.55
0.55
0.58
0.61
0.63
0.64
0.66
0.69
0.71
0.77
0.82
0.88
0.93
1.00
Adjustment
factor
1-in. diameter
Spacing
tension/shear
A
Edge distance
tension
RN
1-1/4-in. diameter
Edge distance
shear
( toward edge)
RV1
Edge distance
shear
(II to or away
from edge)
RV2
Edge distance
Edge distance
shear
Spacing
Edge distance
shear
(II to or away
from edge)
( toward edge)
tension/shear
tension
A
RN
RV1
RV2
Embedment
12
depth, in. 8-1/4 12-3/8 16-1/2 8-1/4 12-3/8 16-1/2 8-1/4 12-3/8 16-1/2 8-1/4 12-3/8 16-1/2
4-1/8
4-1/2
5
6
6-3/16
7
7-1/2
8-1/4
9
10
11
12-3/8
13
14
16
16-1/2
18
18-9/16
22-1/2
24
24-3/4
27
30
33
36
0.70
0.71
0.73
0.77
0.78
0.80
0.82
0.85
0.88
0.91
0.95
1.00
0.70
0.72
0.73
0.75
0.77
0.79
0.82
0.85
0.87
0.89
0.94
0.95
0.99
1.00
0.70
0.71
0.73
0.75
0.78
0.79
0.80
0.84
0.85
0.88
0.89
0.96
0.99
1.00
0.60
0.62
0.64
0.69
0.70
0.74
0.76
0.80
0.84
0.88
0.93
1.00
0.60
0.63
0.64
0.67
0.69
0.72
0.76
0.80
0.82
0.85
0.92
0.93
0.98
1.00
0.60
0.62
0.64
0.67
0.70
0.72
0.74
0.79
0.80
0.84
0.85
0.95
0.98
1.00
0.18
0.20
0.24
0.30
0.32
0.37
0.40
0.45
0.50
0.56
0.63
0.72
0.76
0.83
0.96
1.00
0.18
0.22
0.24
0.27
0.30
0.35
0.39
0.45
0.48
0.52
0.61
0.63
0.70
0.72
0.89
0.96
1.00
0.18
0.20
0.24
0.27
0.32
0.34
0.37
0.43
0.45
0.50
0.52
0.65
0.70
0.72
0.79
0.89
1.00
0.46
0.48
0.50
0.54
0.55
0.59
0.61
0.64
0.67
0.72
0.76
0.82
0.85
0.89
0.98
1.00
15
3.2.3
3.2.4
3.2.3
Table 14 - HVU load adjustment factors for 1-in. and 1-1/4-in. diameter anchors
Anchor
diameter
3.2.3
18
12
15
18
12
15
18
12
15
18
3.2.5
3.2.6
3.2.7
3.2.8
0.46
0.48
0.50
0.52
0.54
0.57
0.60
0.64
0.66
0.69
0.75
0.76
0.80
0.82
0.93
0.98
1.00
0.46
0.48
0.50
0.52
0.55
0.56
0.59
0.63
0.64
0.67
0.69
0.77
0.80
0.82
0.87
0.93
1.00
0.70
0.70
0.73
0.74
0.76
0.78
0.80
0.83
0.86
0.88
0.90
0.95
0.96
1.00
0.70
0.72
0.73
0.75
0.77
0.80
0.81
0.83
0.87
0.88
0.91
0.92
1.00
0.70
0.72
0.73
0.76
0.77
0.78
0.82
0.83
0.85
0.86
0.93
0.95
0.96
1.00
0.60
0.61
0.63
0.65
0.68
0.70
0.73
0.77
0.81
0.83
0.87
0.93
0.95
1.00
0.60
0.62
0.64
0.67
0.69
0.73
0.75
0.77
0.83
0.84
0.88
0.90
1.00
0.60
0.62
0.64
0.68
0.69
0.71
0.76
0.77
0.80
0.81
0.90
0.93
0.95
1.00
0.18
0.19
0.23
0.25
0.28
0.32
0.36
0.41
0.47
0.50
0.54
0.63
0.65
0.72
0.75
0.92
1.00
0.18
0.21
0.23
0.27
0.31
0.36
0.38
0.41
0.49
0.50
0.56
0.58
0.72
0.77
0.80
0.88
1.00
0.18
0.21
0.24
0.28
0.30
0.33
0.39
0.41
0.45
0.47
0.59
0.63
0.65
0.72
0.81
0.90
1.00
0.46
0.47
0.49
0.51
0.53
0.55
0.58
0.61
0.65
0.67
0.70
0.76
0.78
0.82
0.84
0.96
1.00
0.46
0.48
0.50
0.52
0.54
0.58
0.59
0.62
0.66
0.68
0.71
0.73
0.82
0.86
0.87
0.93
1.00
0.46
0.48
0.50
0.53
0.54
0.56
0.60
0.61
0.64
0.65
0.73
0.76
0.78
0.82
0.88
0.94
1.00
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 183
Ammonia
Ammonium nitrate
Ammonium sulphate
Carbolic acid solution
(Phenol)
Carbon tetrachloride
Caustic soda
Sodium hydroxide
Chlorinated lime
solution
Citric acid
Common salt solution
Communal waste water
Diesel oil
Ethanol
Ethylene glycol
Formic acid
Hydrochloric acid
Hydrogen peroxide
Lactic acid
Machine oil
Methanol
Methyl isobutyl ketone
Mixture of amines
Mixture of aromatic
hydrocarbons
Nitric acid
25%
5%
10%
10%
10%
Partially
resistant
Resistant
conc.
10%
10%
conc.
conc.
Vol%1
Vol%2
40%
20%
40%
20%
conc.
conc.
10%
50%
Sulphuric acid
40%
20%
Xylene
conc.
Petrol/Gasoline
Phosphoric acid
2-Propanol
Propylene glycol
Sodium carbonate
Sodium Silicate
(pH=14)
conc.
40%
20%
96%
conc.
10%
20%
30%
5%
50%
10%
53% @ 212F
Acetone
conc.
10%
Not
resistant
80
100% @ 70F
Acetic acid
% by
Weight
Chemical/Liquid
60
40
20
0
20
60
100
140
180
220
Size
(in3)
0.37
0.61
1.04
HVU 3/4
2.07
2.62
HVU 1 (M24)
4.21
9.46
Base material
temperature
F
C
Full cure
time
23
32
5 hr
1 hr
50
10
30 min
above 68
20
20 mn
Detrimental effect
Insignificant
10 100 Mrad
Moderate
Medium to strong
Recommendation
for use
Full Use
Restricted use
Frec. = 0.5 Fperm.
No recommendation
for use
1 Mrad = Megarad
2 Dosage over life span.
Samples of the HVU Resin were immersed in the various chemical compounds for up to one year. At the end of the test period,
the samples were analyzed. Any samples showing no visible damage and having less than a 25% reduction in bending (flexural)
strength were classified as Resistant. Samples that had slight damage, such as small cracks, chips, etc. or reduction in
bending strength of 25% or more, were classified as Partially Resistant. Samples that were heavily damaged or destroyed were
classified as Not Resistant.
184 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Setting Nuts2,3
Qty
Description
Qty
Hole Dia
Std Embed
10
3/8
10
7/16
3-1/2
10
1/2
10
9/16
4-1/4
HVU 5/8 x 5
10
5/8
11/16
3/4
7/8
6-5/8
7/8
6-5/8
HVU 1 x 8-1/4
1-1/8
8-1/4
HVU 1-1/4 x 12
1-1/4
1-3/8
12
Drive Socket
Hole Dia
Std Embed
Qty
Description
10
3/8
9/16
11/16
4-1/4
HVU 5/8 x 5
10
1/2
3/4
7/8
5/8
15/16
1-1/8
6-5/8
HVU 1 x 8-1/4
3/4
1-1/8
1-1/4
8-1/4
Capsule Size
Hole Dia
Std Embed
#4
10
Rebar Adapter #4
5/8
4-1/4
#5
HVU 5/8 x 5
10
Rebar Adapter #5
13/16
#6
Rebar Adapter #6
6-5/8
#7
HVU 1 x 8-1/4
Rebar Adapter #7
1-1/8
6-5/8
#8
10
5
Rebar Adapter #8
1-1/4
8-1/4
Qty
Description
3.2.3
3.2.4
HIS-N Insert
3.2.3
HIS-N Setting Tool
3.2.5
Rebar
Size
3.2.3
HAS-E-Rod
Rebar
3.2.6
3.2.7
3.2.8
Setting Tools
Square Drive Shaft 1/2
HAS Rod Diameter
Drive Socket
3/8
9/16 x 1/2
1/2
3/4 x 1/2
3/4 x 3/4
5/8
15/16 x 1/2
15/16 x 3/4
3/4
1-1/8 x 3/4
7/8
1-7/16 x 3/4
1-1/2 x 3/4
1-1/4
- 1-7/8 x 1
1 All dimensions in inches.
2 To be used with appropriate drive socket and drive shaft from selector chart at left. Setting nuts not required with HIS setting tools.
3 Setting nuts are required for proper fit of drive socket.
4 Setting nuts have a black finished coating except 7/8" which are HDG.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 185
Description
Qty
3/8 x 3
10
360
3/8 x 4-3/8
10
240
10
Qty
Description
3/8x 5-1/8
20
200
3/8 x 5-1/8
3/8 x 5-1/8
20
3/8 x 5-1/8
3/8 x 8
10
160
3/8 x 8
10
3/8 x 12
10
90
3/8 x 8
Qty
10
10
1/2 x 3-1/8
10
240
1/2 x 4-1/2
10
160
1/2 x 6-1/2
20
160
1/2 x 6-1/2
1/2x 8
10
120
1/2 x 10
10
120
1/2 x 12
10
80
5/8 x 8
20
80
5/8 x 7-5/8
5/8 x 9
10
1/2 x 6-1/2
20
1/2 x 6-1/2
10
1/2 x 8
10
1/2 x 8
10
1/2 x 10
10
10
5/8 x 7-5/8
20
10
5/8 x 10
10
60
1/2 x 11 *
10
1/2 x 12
10
5/8 x 7-5/8
10
5/8 x 9
10
10
5/8 x 12
10
60
5/8 x 12
5/8 x 17
10
40
3/4 x 10
10
40
3/4 x 9-5/8
3/4 x 9-5/8
3/4 x 9-5/8 *
3/4 x 10
10
3/4 x 11
10
30
3/4 x 12
10
30
3/4 x 12
10
3/4 x 14
10
30
3/4 x 14 *
3/4 x 14
10
3/4 x 16
10
3/4 x 17
3/4 x 16
10
20
7/8 x 10
3/4 x 19
10
20
3/4 x 21
10
20
7/8 x 16
3/4 x 25
10
20
7/8 x 10
10
20
7/8 x 10 (HDG)
7/8 x 10
7/8 x 12 (HDG) *
7/8 x 13
1 x 12
10
10
20
7/8 x 16 (HDG)
16
1 x 12
1 x 12
1 x 12 *
1 x 14
16
1 x 14 *
1 x 16
12
1 x 16 *
1 x 16 *
4
4
1 x 20
12
1 x 21 *
1 x 20 *
1-1/4 x 16
1-1/4 x 16
1-1/4 x 22
1-1/4 x 23 *
HIS-N carbon steel and HIS-RN 316 stainless steel internally threaded inserts1
Description
Qty
10
1-3/16
5/8 x 6-5/8
1-1/2
3/4 x 8-1/4
3/8 x 4-1/4
1/2 x 5
186 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1.1
Product description
3.3.1.2
Material specifications
3.3.1.3
Technical data
3.3.1.4
3.3.1.5
Ordering information
3.3.1
3.3.2
Guide specifications
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.6
3.3.6
HDA-P
Undercut Anchor
Pre-Set Type
HDA-T
Undercut Anchor
Through-Set Type
Listings/Approvals
ICC-ES (International Code Council)
ESR-1546
City of Los Angeles
No. 25939
European Technical Approval
ETA-99/0009
ETA-99/0016
Qualified under NQA-1 Nuclear Quality
Program
3.3.6
3.3.6
3.3.6
3.3.6
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 187
188 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.2
3.3.3
Minimum embedment
of undercut
HDA-P
HDA-T
3.3.1
3.3.4
3.3.5
3.3.6
Units
M10
M12
M16
M20
3.3.7
do
mm
10
12
16
20
d bit
mm
20
22
30
37
3.3.8
Setting information
1
hef
Hole depth
ho
tfix
tfix
dh
Length of anchor
hmin
Installation torque
Tinst
Wrench size
1
mm
100
125
190
250
(in.)
(3.9)
(4.9)
(7.5)
(9.8)
mm
107
135
203
266
(in.)
(4.2)
(5.3)
(8.0)
(10.5)
3.3.9
3.3.6
3.3.6
See Table 5
mm
21
23
32
40
(in.)
(7/8)
(15/16)
(1-1/4)
(1-9/16)
in.
7-1/8
7-1/2
10-5/8
13-3/4
(mm)
(180)
(200)
(270)
(350)
ft-lb
37
59
88
221
(Nm)
(50)
(80)
(120)
(300)
mm
17
19
24
30
3.3.6
3.3.6
3.3.6
3.3.6
HDA must be installed with the specified Hilti hammer drill and Hilti metric stop bit. See section 3.3.1.5.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 189
Effective
embed.
mm (in.)
Shear - Vn
Tension - Nn
'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
lb (kN)
lb (kN)
lb (kN)"
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
100
7,615
8,345
9,635
11,800
16,405
17,970
20,750
25,415
(3.9)
(33.9)
(37.1)
(42.9)
(52.5)
(73.0)
(79.9)
(92.3)
(113.1)
125
10,645
11,660
13,465
16,490
22,925
25,115
29,000
35,515
(4.9)
(47.4)
(51.9)
(59.9)
(73.4)
(102.0)
(111.7)
(129.0)
(158.0)
190
19,945
21,850
25,230
30,900
42,965
47,065
54,345
66,560
(7.5)
(88.7)
(97.2)
(112.2)
(137.4)
(191.1)
(209.4)
(241.7)
(296.1)
250
30,105
32,980
38,080
46,640
64,845
71,035
82,025
100,460
(9.8)
(133.9)
(146.7)
(169.4)
(207.5)
(288.4)
(316.0)
(364.9)
(446.9)
Table 3 - Hilti HDA-P and HDA-T carbon and stainless steel design strength with concrete / pullout failure
in cracked concrete1,2,3,4,5
Nominal
anchor
diameter
M10
M12
M16
M20
Effective
embed.
mm (in.)
Shear - Vn
Tension - Nn
'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
lb (kN)
lb (kN)
lb (kN)"
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
100
5,845
6,405
7,395
9,055
13,125
14,375
16,600
20,330
(3.9)
(26.0)
(28.5)
(32.9)
(40.3)
(58.4)
(63.9)
(73.8)
(90.4)
125
7,305
8,005
9,240
11,320
18,340
20,090
23,200
28,415
(4.9)
(32.5)
(35.6)
(41.1)
(50.4)
(81.6)
(89.4)
(103.2)
(126.4)
190
14,615
16,005
18,485
22,640
34,370
37,650
43,475
53,245
(7.5)
(65.0)
(71.2)
(82.2)
(100.7)
(152.9)
(167.5)
(193.4)
(236.8)
250
21,920
24,010
27,725
33,955
51,875
56,830
65,620
80,365
(9.8)
(97.5)
(106.8)
(123.3)
(151.0)
(230.8)
(252.8)
(291.9)
(357.5)
190 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Tensile 3 Nsa
lb (kN)
Shear 4 Vsa
lb (kN)
Seismic
shear 5 Vsa
lb (kN)
7,830
3,260
2,920
Tensile 3 Nsa
lb (kN)
Shear 4 Vsa
lb (kN)
Seismic
shear 5 Vsa
lb (kN)
7,830
3,945
3,655
(34.8)
(14.5)
(13.0)
(34.8)
(17.5)
(16.3)
11,395
4,735
4,235
11,395
5,845
5,260
(50.7)
(21.1)
(18.8)
(50.7)
(26.0)
(23.4)
21,140
8,810
7,890
21,140
10,960
9,790
(94.0)
(39.2)
(35.1)
(94.0)
(48.8)
(43.5)
3.3.1
33,060
13,500
12,130
(147.1)
(60.1)
(54.0)
n/a
n/a
n/a
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
Table 5 - Steel strength for Hilti HDA-T carbon steel and stainless steel anchors1,2
HDA-T carbon steel anchors
Nominal
anchor
diameter
M10
Thickness of
fastened parts tfix
in. (mm)
Tensile 3 Nsa
lb (kN)
Shear 4 Vsa
lb (kN)
Seismic
shear 5 Vsa
lb (kN)
Tensile 3 Nsa
lb (kN)
Shear 4 Vsa
lb (kN)
Seismic
shear 5 Vsa
lb (kN)
7,830
9,060
8,185
7,830
10,080
9,060
(34.8)
(40.3)
(36.4)
(34.8)
(44.8)
(40.3)
10,815
9,790
13,155
11,690
(48.1)
(43.5)
(58.5)
(52.0)
M16
M20
1
2
3
4
5
3.3.7
11,395
(50.7)
11,395
(50.7)
3.3.8
3.3.9
3.3.6
3.3.6
12,130
10,815
14,465
13,005
(54.0)
(48.1)
(64.3)
(57.8)
19,875
17,825
23,235
20,900
3.3.6
3.3.6
(88.4)
(79.3)
(103.4)
(93.0)
22,505
20,315
24,550
22,065
(100.1)
(90.4)
(109.2)
(98.1)
21,140
(94.0)
21,140
(94.0)
24,845
22,355
25,715
23,090
(110.5)
(99.4)
(114.4)
(102.7)
26,885
24,110
26,595
23,965
(119.6)
(107.2)
(118.3)
(106.6)
29,370
26,450
n/a
n/a
(130.6)
(117.7)
33,025
29,665
(146.9)
(132.0)
35,510
32,005
(158.0)
(142.4)
33,060
(147.1)
n/a
3.3.6
3.3.6
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 191
Nominal diameter
Effective
mm
embedment hef
(in.)
3-1/8
3-1/2
4
4-1/2
5
6
7
7-1/8
7-1/2
8
9
10
11
12
14
16
18
20
24
30
36
42
(79)
(89)
(102)
(114)
(127)
(152)
(178)
(181)
(191)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
(1067)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
Conc. thickness
factor in shear 4
HV
M10
M12
M10
M12
M10
M12
M10
M12
M10
M12
M10
M12
100
(3.94)
n/a
n/a
0.67
0.69
0.71
0.75
0.80
0.80
0.82
0.84
0.88
0.92
0.97
1.00
125
(4.92)
n/a
n/a
n/a
n/a
0.67
0.70
0.74
0.74
0.75
0.77
0.80
0.84
0.87
0.91
0.97
1.00
100
(3.94)
0.66
0.70
0.76
0.82
0.88
1.00
125
(4.92)
n/a
n/a
0.66
0.71
0.76
0.86
0.96
0.97
1.00
100
(3.94)
n/a
n/a
0.56
0.56
0.57
0.59
0.60
0.60
0.61
0.61
0.63
0.64
0.66
0.67
0.70
0.73
0.76
0.79
0.84
0.93
1.00
125
(4.92)
n/a
n/a
n/a
n/a
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.64
0.67
0.69
0.72
0.74
0.79
0.86
0.93
1.00
100
(3.94)
0.14
0.17
0.20
0.24
0.28
0.37
0.47
0.48
0.52
0.57
0.68
0.80
0.92
1.00
125
(4.92)
n/a
n/a
0.15
0.18
0.22
0.28
0.36
0.37
0.40
0.44
0.52
0.61
0.70
0.80
1.00
100
(3.94)
0.28
0.33
0.40
0.48
0.56
0.74
0.93
0.96
1.00
125
(4.92)
n/a
n/a
0.31
0.37
0.43
0.57
0.71
0.73
0.79
0.87
1.00
100
(3.94)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.64
0.66
0.68
0.72
0.76
0.79
0.83
0.90
0.96
1.00
125
(4.92)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.66
0.69
0.73
0.76
0.82
0.88
0.93
0.98
1.00
Table 7 - Load adjustment factors for M10 and M12 HDA-P and HDA-T carbon and stainless steel anchors in cracked concrete1,2
M10 and M12
HDA-P and HDA-T
cracked concrete
Nominal diameter
Effective
mm
embedment hef
(in.)
1
2
3
4
3-1/8
3-1/2
4
4-1/2
5
6
7
7-1/8
7-1/2
8
9
10
11
12
14
16
18
20
24
30
36
42
> 48
(79)
(89)
(102)
(114)
(127)
(152)
(178)
(181)
(191)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
(1067)
(1219)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
Conc. thickness
factor in shear 4
HV
M10
M12
M10
M12
M10
M12
M10
M12
M10
M12
M10
M12
100
(3.94)
n/a
n/a
0.67
0.69
0.71
0.75
0.80
0.80
0.82
0.84
0.88
0.92
0.97
1.00
125
(4.92)
n/a
n/a
n/a
n/a
0.67
0.70
0.74
0.74
0.75
0.77
0.80
0.84
0.87
0.91
0.97
1.00
100
(3.94)
0.66
0.70
0.76
0.82
0.88
1.00
125
(4.92)
n/a
n/a
0.66
0.71
0.76
0.86
0.96
0.97
1.00
100
(3.94)
n/a
n/a
0.55
0.56
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.82
0.90
0.98
1.00
125
(4.92)
n/a
n/a
n/a
n/a
0.56
0.57
0.58
0.58
0.58
0.59
0.60
0.61
0.62
0.63
0.66
0.68
0.70
0.72
0.77
0.83
0.90
0.97
1.00
100
(3.94)
0.12
0.15
0.18
0.21
0.25
0.33
0.42
0.43
0.46
0.51
0.61
0.71
0.82
0.94
1.00
125
(4.92)
n/a
n/a
0.14
0.16
0.19
0.25
0.32
0.33
0.35
0.39
0.46
0.54
0.63
0.71
0.90
1.00
100
(3.94)
0.25
0.29
0.36
0.43
0.50
0.66
0.83
0.86
0.92
1.00
125
(4.92)
n/a
n/a
0.27
0.33
0.38
0.50
0.64
0.65
0.71
0.78
0.93
1.00
100
(3.94)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.63
0.65
0.69
0.73
0.76
0.80
0.86
0.92
0.98
1.00
125
(4.92)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.60
0.63
0.67
0.70
0.73
0.79
0.84
0.89
0.94
1.00
192 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Nominal diameter
Effective
mm
embedment hef
(in.)
3-1/8
(79)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
7-1/8
(181)
7-1/2
(191)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
30
(762)
36
(914)
42
(1067)
> 48
(1219)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
Conc. thickness
factor in shear 4
HV
M16
M20
M16
M20
M16
M20
M16
M20
M16
M20
M16
M20
190
(7.48)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.68
0.70
0.72
0.75
0.77
0.81
0.86
0.90
0.95
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.69
0.70
0.74
0.77
0.80
0.84
0.91
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
0.66
0.72
0.73
0.75
0.78
0.85
0.91
0.98
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.86
0.96
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.56
0.57
0.58
0.59
0.59
0.61
0.63
0.64
0.66
0.69
0.74
0.78
0.83
0.88
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.57
0.57
0.58
0.60
0.61
0.62
0.64
0.68
0.72
0.75
0.79
190
(7.48)
n/a
n/a
n/a
n/a
n/a
0.15
0.19
0.20
0.21
0.23
0.28
0.32
0.37
0.43
0.54
0.66
0.78
0.92
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.15
0.18
0.22
0.25
0.28
0.36
0.44
0.52
0.61
0.80
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
0.30
0.38
0.39
0.42
0.46
0.55
0.65
0.75
0.85
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.31
0.37
0.43
0.50
0.57
0.71
0.87
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.59
0.61
0.66
0.71
0.75
0.79
0.87
0.97
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.58
0.62
0.66
0.69
0.76
0.85
0.93
1.00
Table 9 - Load adjustment factors for M16 and M20 HDA-P and HDA-T carbon and stainless steel anchors in cracked concrete
M16 and M20
HDA-P and HDA-T
cracked concrete
Nominal diameter
Effective
mm
embedment hef
(in.)
1
2
3
4
3-1/8
3-1/2
4
4-1/2
5
6
7
7-1/8
7-1/2
8
9
10
11
12
14
16
18
20
24
30
36
42
> 48
(79)
(89)
(102)
(114)
(127)
(152)
(178)
(181)
(191)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
(1067)
(1219)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
1,2
Conc. thickness
factor in shear 4
HV
M16
M20
M16
M20
M16
M20
M16
M20
M16
M20
M16
M20
190
(7.48)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.68
0.70
0.72
0.75
0.77
0.81
0.86
0.90
0.95
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.69
0.70
0.74
0.77
0.80
0.84
0.91
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
0.66
0.72
0.73
0.75
0.78
0.85
0.91
0.98
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.86
0.96
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.62
0.63
0.65
0.68
0.72
0.76
0.81
0.85
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.67
0.70
0.73
0.77
190
(7.48)
n/a
n/a
n/a
n/a
n/a
0.13
0.17
0.17
0.19
0.21
0.25
0.29
0.33
0.38
0.48
0.59
0.70
0.82
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.14
0.16
0.19
0.22
0.25
0.32
0.39
0.46
0.54
0.71
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
0.27
0.34
0.35
0.38
0.41
0.49
0.58
0.67
0.76
0.96
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.27
0.33
0.38
0.44
0.50
0.64
0.78
0.93
1.00
190
(7.48)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.59
0.64
0.68
0.72
0.76
0.84
0.94
1.00
250
(9.84)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.60
0.63
0.67
0.73
0.82
0.89
0.97
1.00
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.6
3.3.6
3.3.6
3.3.6
3.3.6
3.3.6
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 193
M10x100/20
150 mm
M12x125/30
190 mm
M12x125/50
210 mm
M16x190/40
275 mm
M16x190/40
295 mm
M20x250/50
360 mm
M20x250/100
410 mm
HDA-T
HDA-TF
HDA-TR
HDA
Box
Qty
Description (mm)
dia. x drill depth
Diameter
12
TE-C-B20x120
TE-Y-B20x120
TE-C-B22x155
TE-Y-B22x155
TE-C-B22x175
TE-Y-B22x175
TE-Y B30x230
Description
TE-C-ST 20 M10
TE-Y-ST 20 M10
TE-C-ST 22 M12
TE-Y-ST 22 M12
TE-C-ST 22 M12
TE-Y-ST 22 M12
20mm
22mm
22mm
TE-Y B30x250
Setting tool
30mm
TE-Y-ST 30 M16
37mm
TE-Y-ST 37 M20
TE-Y B37x300
TE-Y B37x350
1 The drilling depth with the diamond core bit must not exceed 2/3 of the specified minimum drill hole depth. The last 1/3 of the drill hole depth must be completed
with the specified hammer drill and stop drill bit. Always consult the engineer of record before cutting rebar.
HDA-P anchor
Description
bolt dia. x hef / tfix,max
overall length
M10x100/20
150 mm
M12x125/30
190 mm
M12x125/50
210 mm
M16x190/40
275 mm
M16x190/40
295 mm
M20x250/50
360 mm
M20x250/100
410 mm
HDA-P
HDA-PF
HDA-PR
HDA
Box
Qty
Description (mm)
dia. x drill depth
Diameter
12
TE-C B20x100
TE-Y B20x100
TE-C B22x125
TE-Y B22x125
TE-C-B22x125
TE-Y-B22x125
Setting tool
Description
TE-C-ST 20 M10
TE-Y-ST 20 M10
TE-C-ST 22 M12
TE-Y-ST 22 M12
TE-C-ST 22 M12
TE-Y-ST 22 M12
20mm
22mm
22mm
TE-Y B30x190
30mm
TE-Y-ST 30 M16
TE-Y B37x250
37mm
TE-Y-ST 37 M20
1 The drilling depth with the diamond core bit must not exceed 2/3 of the specified minimum drill hole depth. The last 1/3 of the drill hole depth must be completed
with the specified hammer drill and stop drill bit. Always consult the engineer of record before cutting rebar.
Description
Qty/pkg
Applicable
anchor sizes
TE-C-HDA-RT 20-M10
HDA M10
TE-C-HDA-RT 22-M12
HDA M12
TE-C-HDA-RT 30-M16
HDA M16
TE-C-HDA-RT 37-M20
HDA M20
194 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
TE 35
TE 40/
40-AVR
TE 56/
56-ATC
TE-C
TE 75
TE-76/
76-ATC
TE 80ATC
TE-Y
HDA-P M10x100/20
HDA-T M10x100/20
HDA-P M12x125/30
HDA-T M12x125/30
HDA-P M12x125/50
HDA-T M12x125/50
3.3.1
HDA-P M16x190/40
HDA-T M16x190/40
HDA-P M16x190/60
HDA-T M16x190/60
HDA-P M20x250/50
HDA-T M20x250/50
HDA-P M20x250/100
HDA-T M20x250/100
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
TE 35
TE 40/
40-AVR
TE 56/
56-ATC
TE-C
TE 75
TE-76/
76-ATC
TE 80ATC
TE-Y
HDA-PR M10x100/20
HDA-TR M10x100/20
HDA-PR M12x125/30
HDA-TR M12x125/30
HDA-PR M12x125/50
HDA-TR M12x125/50
3.3.6
3.3.6
HDA-PR M16x190/60
HDA-PR M16x190/60
HDA-TR M16x190/60
Anchor
TE 35
3.3.6
3.3.6
3.3.6
3.3.9
3.3.6
HDA-PR M16x190/40
TE 25
(1st gear)
3.3.8
TE 56/
56-ATC
TE-C
TE 75
TE-76/
76-ATC
TE 80ATC
TE-Y
HDA-PFM10x100/20
HDA-TF M10x100/20
HDA-PF M12x125/30
HDA-TF M12x125/30
HDA-PF M12x125/50
HDA-TF M12x125/50
HDA-PF M16x190/40
HDA-TF M16x190/40
HDA-PF M16x190/60
HDA-TF M16x190/60
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 195
Notes
196 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Maximum fastened
thickness (mm)
HSL-3-G M12 / 25
Heavy-duty
Expansion
Anchor
blank-bolt
G-stud
B-torque cap
Metric thread
size (mm); not
hole diameter
3.3.2.1
Product description
3.3.2.2
Material specifications
3.3.2.3
Technical data
3.3.2.4
Installation instructions
3.3.2.5
Ordering information
Bolt
Washer
3.3.1
Minimum
embedment
mark
Spacer
sleeve
Plastic
collapsible
section
with anchor
rotation
prevention
Expansion
sleeve
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
Cone
3.3.9
Listings/Approvals
3.3.9
3.3.9
3.3.9
Carbon steel washer conforms to DIN 1544, Grade St37, futa > 100 ksi.
Carbon steel expansion cone conforms to DIN 1654-4, futa > 80 ksi.
Carbon steel expansion sleeve M8-M16 conforms to DIN 10139 and M20-M24 conforms
to DIN 2393-2.
Carbon steel spacing sleeve conforms to DIN 2393 T1, futa > 100 ksi.
Collapsible sleeve is made from acetal polyoxymethylene (POM) resin.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 197
d bit
hmin
ho
hef,min
dh
tfix
Washer diameter
Installation torque HSL-3
Installation torque HSL-3-G
dw
Tinst
Tinst
M8
12
mm
M10
15
M12
18
mm
M16
24
M20
28
M24
32
See table 5
(in.)
mm
80
90
105
125
155
180
(in.)
(3-1/8)
(3-1/2)
(4-1/8)
(4-7/8)
(6-1/8)
(7-1/8)
mm
60
70
80
100
125
150
(in.)
(2-3/8)
(2-3/4)
(3-1/8)
(3-7/8)
(4-7/8)
(5-7/8)
mm
14
17
20
26
31
35
(in.)
(9/16)
(11/16)
(13/16)
(1)
(1-1/4)
(1-3/8)
mm
12
16
(in.)
mm
(in.)
mm
(in.)
(1/8)
20
(3/16)
40
20
40
118
110
130
(5/16)
(3/8)
(1/2)
25
50
25
50
(1)
(2)
(1)
(2)
131
156
153
178
(6)
(7)
mm
20
20
25
50
25
50
(in.)
(3/4)
(3/4)
(1)
(2)
(1)
(2)
mm
102
115
139
164
163
188
30
(5/8)
60
30
60
213
(7-1/4) (8-3/8)
30
205
235
(8)
(9-1/4)
60
(1-1/8) (2-1/4)
190
220
(in.)
(4)
(4-1/2)
mm
20
25
30
40
45
(in.)
(3/4)
(1)
(1-1/8)
(1-9/16)
(1-3/4)
(2)
Nm
25
50
80
120
200
250
(ft-lb)
(18)
(37)
(59)
(89)
(148)
(185)
Nm
20
35
60
80
160
(ft-lb)
(15)
(26)
(44)
(59)
(118)
mm
13
17
19
24
30
36
mm
24
30
36
41
Figure 1
Data development
The technical data contained in this section are Hilti Simplified Design Tables.
The load values were developed using the Strength Design parameters and
variables of ESR-1545 and the equations within ACI 318-11 Appendix D. For a
detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.7.
Data tables from ESR-1545 are not contained in this section, but can be found on
www.icc-es.org or at www.us.hilti.com.
198 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Effective
embed.
mm (in.)
Shear - Vn
Tension - Nn
'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
lb (kN)
lb (kN)
lb (kN)"
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
60
2,735
2,995
3,455
4,235
3,050
3,340
3,860
4,725
(2.4)
(12.2)
(13.3)
(15.4)
(18.8)
(13.6)
(14.9)
(17.2)
(21.0)
70
3,570
3,910
4,515
5,530
7,685
8,420
9,720
11,905
(2.8)
(15.9)
(17.4)
(20.1)
(24.6)
(34.2)
(37.5)
(43.2)
(53.0)
80
4,360
4,775
5,515
6,755
9,390
10,285
11,880
14,550
(3.2)
(19.4)
(21.2)
(24.5)
(30.0)
(41.8)
(45.7)
(52.8)
(64.7)
100
6,095
6,675
7,705
9,440
13,125
14,375
16,600
20,330
(3.9)
(27.1)
(29.7)
(34.3)
(42.0)
(58.4)
(63.9)
(73.8)
(90.4)
M8
M10
M12
M16
M20
M24
3.3.2
125
8,515
9,330
10,770
13,190
18,340
20,090
23,200
28,415
(4.9)
(37.9)
(41.5)
(47.9)
(58.7)
(81.6)
(89.4)
(103.2)
(126.4)
150
11,195
12,260
14,160
17,340
24,110
26,410
30,495
37,350
3.3.4
(5.9)
(49.8)
(54.5)
(63.0)
(77.1)
(107.2)
(117.5)
(135.6)
(166.1)
3.3.5
Effective
embed.
mm (in.)
3.3.7
Shear - Vn
Tension - Nn
3.3.3
3.3.6
Table 3 - Hilti HSL-3 design strength with concrete / pullout failure in cracked concrete1,2,3,4,5
Nominal
anchor
diameter
3.3.1
'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
lb (kN)
lb (kN)
lb (kN)"
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
60
1,825
2,000
2,310
2,830
2,160
2,365
2,730
3,345
(2.4)
(8.1)
(8.9)
(10.3)
(12.6)
(9.6)
(10.5)
(12.1)
(14.9)
70
2,920
3,200
3,695
4,525
7,685
8,420
9,720
11,905
(2.8)
(13.0)
(14.2)
(16.4)
(20.1)
(34.2)
(37.5)
(43.2)
(53.0)
3.3.8
3.3.9
3.3.9
3.3.9
80
4,360
4,775
5,515
6,755
9,390
10,285
11,880
14,550
(3.2)
(19.4)
(21.2)
(24.5)
(30.0)
(41.8)
(45.7)
(52.8)
(64.7)
100
6,095
6,675
7,705
9,440
13,125
14,375
16,600
20,330
3.3.9
3.3.9
(3.9)
(27.1)
(29.7)
(34.3)
(42.0)
(58.4)
(63.9)
(73.8)
(90.4)
125
8,515
9,330
10,770
13,190
18,340
20,090
23,200
28,415
(4.9)
(37.9)
(41.5)
(47.9)
(58.7)
(81.6)
(89.4)
(103.2)
(126.4)
150
11,195
12,260
14,160
17,340
24,110
26,410
30,495
37,350
(5.9)
(49.8)
(54.5)
(63.0)
(77.1)
(107.2)
(117.5)
(135.6)
(166.1)
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 199
HSL-3-G
Tensile 3 Nsa
lb (kN)
Shear 4 Vsa
lb (kN)
Seismic
shear 5 Vsa
lb (kN)
Tensile 3 Nsa
lb (kN)
Shear 4 Vsa
lb (kN)
Seismic
shear 5 Vsa
lb (kN)
4,960
4,705
2,995
4,960
3,945
2,455
(22.1)
(20.9)
(13.3)
(22.1)
(17.5)
(10.9)
7,830
6,650
5,495
7,830
5,450
4,500
(34.8)
(29.6)
(24.4)
(34.8)
(24.2)
(20.0)
11,395
9,570
7,730
11,395
7,905
6,385
(50.7)
(42.6)
(34.4)
(50.7)
(35.2)
(28.4)
21,140
17,360
16,115
21,140
14,745
13,690
(94.0)
(77.2)
(71.7)
(94.0)
(65.6)
(60.9)
33,060
25,690
18,940
33,060
21,555
15,900
(147.1)
(95.9)
(70.7)
n/a
n/a
n/a
(147.1)
(114.3)
(84.2)
47,590
29,870
24,810
(211.7)
(132.9)
(110.4)
200 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Dimensional parameter
Symbol
hmin
Units
in.
(mm)
M8
M10
M12
M16
M20
M24
4-3/4
(120)
5-1/2
(140)
6-1/4
(160)
7-7/8
(200)
9-7/8
(250)
11-7/8
(300)
cac
in.
(mm)
4-3/8
(110)
4-3/8
(110)
4-3/4
(120)
5-7/8
(150)
8-7/8
(225)
8-7/8
(225)
cmin,1
in.
(mm)
2-3/8
(60)
2-3/4
(70)
3-1/2
(90)
4-3/4
(120)
5
(125)
5-7/8
(150)
smin,1
in.
(mm)
5-1/2
(140)
9-1/2
(240)
11
(280)
12-5/8
(320)
13-3/4
(350)
11-7/8
(300)
cmin,2
in.
(mm)
3-3/8
(85)
5
(125)
6-1/8
(155)
7-7/8
(200)
8-1/4
(210)
8-1/4
(210)
smin,2
in.
(mm)
2-3/8
(60)
2-3/4
(70)
3-1/8
(80)
4
(100)
5
(125)
5-7/8
(150)
4-3/8
(110)
4-3/4
(120)
5-3/8
(135)
6-1/4
(160)
7-1/2
(190)
8-7/8
(225)
3.3.1
3.3.2
3.3.3
hmin
in.
(mm)
cac
in.
(mm)
5-7/8
(150)
6-7/8
(175)
7-7/8
(200)
9-7/8
(250)
12-3/8
(312.5)
14-3/4
(375)
3.3.5
cmin,1
in.
(mm)
2-3/8
(60)
3-1/2
(90)
4-3/8
(110)
6-1/4
(160)
7-7/8
(200)
8-7/8
(225)
3.3.6
smin,1
in.
(mm)
7
(180)
10-1/4
(260)
12-5/8
(320)
15
(380)
15-3/4
(400)
15
(380)
cmin,2
in.
(mm)
4
(100)
6-1/4
(160)
7-7/8
(200)
10-5/8
(270)
11-7/8
(300)
12-5/8
(320)
smin,2
in.
(mm)
2-3/8
(60)
2-3/4
(70)
3-1/8
(80)
4
(100)
5
(125)
5-7/8
(150)
3.3.4
3.3.7
3.3.8
3.3.9
3.3.9
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge distance c, where cmin,1 < c < cmin,2 will determine the permissible spacing s as follows:
3.3.9
(smin,1 smin,2)
s smin,2 + ___________ (c cmin,2)
(cmin,1 cmin,2)
3.3.9
3.3.9
Figure 2
3.3.9
cmin,2
Case 2
cmin,1
Case 1
smin,2
smin,1
3.3.9
cmin,1 at smin,1
sdesign
cmin,2 at smin,2
Concrete
Edge
cdesign
edge distance c
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 201
Spacing factor
in tension
AN
M8
60
(2.36)
0.67
0.68
0.69
0.71
0.72
0.75
0.78
0.81
0.82
0.84
0.85
0.88
0.92
0.99
1.00
M10
70
(2.76)
n/a
n/a
0.67
0.68
0.69
0.71
0.74
0.76
0.77
0.79
0.80
0.83
0.86
0.92
0.98
1.00
1.00
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
0.67
0.69
0.71
0.73
0.74
0.75
0.76
0.78
0.82
0.87
0.92
0.98
1.00
1.00
1.00
Edge distance
factor in tension
RN
M8
60
(2.36)
0.45
0.47
0.50
0.53
0.55
0.60
0.68
0.74
0.77
0.81
0.85
0.91
1.00
M10
70
(2.76)
n/a
n/a
0.45
0.48
0.49
0.53
0.59
0.64
0.65
0.69
0.73
0.78
0.87
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
0.48
0.53
0.56
0.58
0.60
0.63
0.68
0.76
0.89
1.00
Spacing factor
in shear 3
AV
M8
60
(2.36)
0.58
0.58
0.59
0.60
0.60
0.62
0.63
0.65
0.65
0.66
0.67
0.68
0.70
0.73
0.77
0.80
0.83
0.90
0.96
1.00
M10
70
(2.76)
n/a
n/a
0.55
0.56
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.60
0.62
0.64
0.65
0.67
0.69
0.73
0.77
0.81
0.85
0.89
0.96
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
0.56
0.56
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.63
0.64
0.66
0.68
0.72
0.75
0.79
0.82
0.86
0.93
1.00
M10
70
(2.76)
n/a
n/a
0.18
0.20
0.22
0.26
0.32
0.36
0.38
0.41
0.44
0.49
0.58
0.73
0.89
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
0.23
0.28
0.32
0.34
0.37
0.40
0.44
0.52
0.65
0.80
0.95
1.00
II to edge
RV
M8
60
(2.36)
0.45
0.47
0.50
0.53
0.55
0.60
0.71
0.81
0.85
0.92
0.99
1.00
M10
70
(2.76)
n/a
n/a
0.36
0.41
0.44
0.52
0.59
0.64
0.65
0.69
0.73
0.78
0.87
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
0.46
0.53
0.56
0.58
0.60
0.63
0.68
0.76
0.89
1.00
M8
60
(2.36)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.76
0.77
0.79
0.81
0.84
0.89
0.96
1.00
M10
70
(2.76)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.61
0.62
0.64
0.68
0.73
0.79
0.83
0.88
0.96
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.66
0.71
0.76
0.80
0.85
0.93
1.00
Table 7 - Load adjustment factors for M8, M10, and M12 HSL-3 anchors in cracked concrete1,2
1
2
3
4
Spacing factor
in tension
AN
M8
60
(2.36)
0.67
0.68
0.69
0.71
0.72
0.75
0.78
0.81
0.82
0.84
0.85
0.88
0.92
0.99
1.00
M10
70
(2.76)
n/a
n/a
0.67
0.68
0.69
0.71
0.74
0.76
0.77
0.79
0.80
0.83
0.86
0.92
0.98
1.00
1.00
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
0.67
0.69
0.71
0.73
0.74
0.75
0.76
0.78
0.82
0.87
0.92
0.98
1.00
1.00
1.00
Edge distance
factor in tension
RN
M8
60
(2.36)
0.75
0.78
0.83
0.88
0.91
0.99
1.00
M10
70
(2.76)
n/a
n/a
0.75
0.79
0.81
0.88
0.97
1.00
1.00
1.00
1.00
1.00
1.00
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
0.80
0.88
0.94
0.96
1.00
1.00
1.00
1.00
1.00
1.00
Spacing factor
in shear 3
AV
M8
60
(2.36)
0.58
0.58
0.59
0.60
0.60
0.62
0.63
0.65
0.65
0.66
0.67
0.68
0.70
0.73
0.77
0.80
0.83
0.90
0.97
1.00
M10
70
(2.76)
n/a
n/a
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.57
0.58
0.58
0.59
0.61
0.62
0.64
0.65
0.69
0.72
0.75
0.78
0.81
0.87
0.96
M12
80
(3.15)
n/a
n/a
n/a
n/a
0.54
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.67
0.70
0.73
0.76
0.79
0.84
0.93
M10
70
(2.76)
n/a
n/a
0.13
0.15
0.16
0.18
0.23
0.26
0.27
0.29
0.31
0.35
0.41
0.52
0.64
0.76
0.89
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
0.17
0.20
0.23
0.24
0.26
0.28
0.31
0.37
0.47
0.57
0.68
0.80
1.00
II to edge
RV
M8
60
(2.36)
0.65
0.71
0.82
0.88
0.91
0.99
1.00
M10
70
(2.76)
n/a
n/a
0.26
0.29
0.31
0.37
0.45
0.51
0.54
0.58
0.63
0.70
0.83
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
0.33
0.40
0.46
0.48
0.52
0.56
0.63
0.74
0.93
1.00
M8
60
(2.36)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.76
0.77
0.80
0.82
0.85
0.89
0.97
1.00
M10
70
(2.76)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.54
0.56
0.58
0.61
0.66
0.70
0.74
0.79
0.86
0.93
0.99
1.00
M12
80
(3.15)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.59
0.63
0.68
0.72
0.76
0.83
0.90
0.96
1.00
202 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in tension
AN
M16
100
(3.94)
0.67
0.69
0.70
0.71
0.73
0.75
0.75
0.76
0.80
0.82
0.84
0.88
0.88
0.92
0.97
1.00
1.00
1.00
M20
125
(4.92)
n/a
n/a
n/a
0.67
0.69
0.70
0.70
0.71
0.74
0.75
0.77
0.80
0.80
0.84
0.87
0.91
0.97
1.00
M24
150
(5.91)
n/a
n/a
n/a
n/a
n/a
0.67
0.67
0.68
0.70
0.71
0.73
0.75
0.75
0.78
0.81
0.84
0.90
0.95
1.00
Edge distance
factor in tension
RN
M16
100
(3.94)
n/a
n/a
0.51
0.53
0.57
0.60
0.61
0.63
0.71
0.76
0.81
0.90
0.91
1.00
1.00
M20
125
(4.92)
n/a
n/a
n/a
0.45
0.48
0.50
0.51
0.53
0.57
0.61
0.65
0.72
0.73
0.81
0.89
0.97
1.00
M24
150
(5.91)
n/a
n/a
n/a
n/a
n/a
0.45
0.45
0.47
0.50
0.53
0.55
0.60
0.61
0.68
0.75
0.81
0.95
1.00
Spacing factor
in shear 3
AV
M16
100
(3.94)
0.56
0.57
0.58
0.58
0.59
0.59
0.59
0.60
0.61
0.62
0.63
0.64
0.64
0.66
0.67
0.69
0.72
0.75
0.78
0.82
0.88
0.97
1.00
M20
125
(4.92)
n/a
n/a
n/a
0.57
0.57
0.58
0.58
0.58
0.59
0.60
0.61
0.62
0.62
0.63
0.65
0.66
0.69
0.71
0.74
0.77
0.82
0.90
0.98
1.00
M24
150
(5.91)
n/a
n/a
n/a
n/a
n/a
0.57
0.57
0.57
0.58
0.59
0.59
0.60
0.60
0.62
0.63
0.64
0.66
0.69
0.71
0.73
0.78
0.85
0.92
1.00
M20
125
(4.92)
n/a
n/a
n/a
0.25
0.29
0.32
0.33
0.35
0.42
0.46
0.51
0.60
0.61
0.71
0.82
0.94
1.00
M24
150
(5.91)
n/a
n/a
n/a
n/a
n/a
0.26
0.27
0.29
0.34
0.38
0.41
0.48
0.49
0.58
0.67
0.76
0.96
1.00
II to edge
RV
M16
100
(3.94)
n/a
n/a
0.51
0.53
0.57
0.60
0.61
0.63
0.71
0.76
0.81
0.90
0.91
1.00
1.00
M20
125
(4.92)
n/a
n/a
n/a
0.45
0.48
0.50
0.51
0.53
0.57
0.61
0.65
0.72
0.73
0.81
0.89
0.97
1.00
M24
150
(5.91)
n/a
n/a
n/a
n/a
n/a
0.45
0.45
0.47
0.50
0.53
0.55
0.60
0.61
0.68
0.75
0.81
0.96
1.00
M16
100
(3.94)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.67
0.69
0.71
0.75
0.75
0.79
0.83
0.87
0.94
1.00
M20
125
(4.92)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.65
0.69
0.69
0.73
0.77
0.80
0.86
0.92
0.98
1.00
M24
150
(5.91)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.64
0.65
0.68
0.71
0.75
0.80
0.86
0.91
0.96
1.00
1
2
3
4
4
4-1/2
4-3/4
5
5-1/2
5-7/8
6
6-1/4
7
7-1/2
8
8-7/8
9
10
11
12
14
16
18
20
24
30
36
> 48
(102)
(114)
(121)
(127)
(140)
(149)
(152)
(159)
(178)
(191)
(203)
(225)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
(1219)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
Table 9 - Load adjustment factors for M16, M20, and M24 HSL-3 anchors in cracked concrete1,4
M16, M20 and M24
HSL-3
cracked concrete
Nominal dia.
mm
Effective
embedment hef
(in.)
3.3.1
II to edge
RV
M16
100
M20
125
M24
150
M16
100
M20
125
M24
150
M16
100
M20
125
M24
150
M16
100
M20
125
M24
150
M16
100
M20
125
M24
150
M16
100
M20
125
M24
150
(3.94)
(4.92)
(5.91)
(3.94)
(4.92)
(5.91)
(3.94)
(4.92)
(5.91)
(3.94)
(4.92)
(5.91)
(3.94)
(4.92)
(5.91)
(3.94)
(4.92)
(5.91)
0.67
0.69
0.70
0.71
0.73
0.75
0.75
0.76
0.80
0.82
0.84
0.88
0.88
0.92
0.97
1.00
1.00
1.00
n/a
n/a
n/a
0.67
0.69
0.70
0.70
0.71
0.74
0.75
0.77
0.80
0.80
0.84
0.87
0.91
0.97
1.00
n/a
n/a
n/a
n/a
n/a
0.67
0.67
0.68
0.70
0.71
0.73
0.75
0.75
0.78
0.81
0.84
0.90
0.95
1.00
n/a
n/a
0.85
0.88
0.95
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
n/a
n/a
n/a
0.76
0.81
0.84
0.86
0.88
0.96
1.00
1.00
1.00
1.00
1.00
1.00
1.00
n/a
n/a
n/a
n/a
n/a
0.75
0.76
0.78
0.84
0.88
0.92
1.00
1.00
1.00
1.00
1.00
1.00
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.61
0.63
0.64
0.65
0.68
0.70
0.73
0.75
0.80
0.88
0.95
1.00
n/a
n/a
n/a
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.59
0.59
0.60
0.61
0.62
0.63
0.65
0.67
0.69
0.71
0.76
0.82
0.88
1.00
n/a
n/a
n/a
n/a
n/a
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.60
0.61
0.63
0.65
0.67
0.68
0.72
0.78
0.83
0.94
n/a
n/a
0.22
0.23
0.27
0.30
0.31
0.33
0.39
0.43
0.47
0.55
0.56
0.66
0.76
0.87
1.00
n/a
n/a
n/a
0.18
0.21
0.23
0.24
0.25
0.30
0.33
0.36
0.43
0.43
0.51
0.59
0.67
0.84
1.00
n/a
n/a
n/a
n/a
n/a
0.19
0.19
0.20
0.24
0.27
0.30
0.35
0.35
0.41
0.48
0.54
0.68
0.84
1.00
1.00
n/a
n/a
0.43
0.47
0.54
0.59
0.61
0.65
0.77
0.86
0.94
1.00
1.00
1.00
1.00
n/a
n/a
n/a
0.36
0.42
0.46
0.47
0.50
0.60
0.66
0.73
0.85
0.87
1.00
1.00
1.00
n/a
n/a
n/a
n/a
n/a
0.37
0.38
0.41
0.48
0.54
0.59
0.69
0.71
0.83
0.95
1.00
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.59
0.62
0.64
0.67
0.67
0.71
0.75
0.78
0.84
0.90
0.95
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.56
0.58
0.61
0.62
0.65
0.68
0.71
0.77
0.82
0.87
0.92
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.57
0.58
0.61
0.64
0.67
0.72
0.77
0.82
0.86
0.94
1.00
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 203
Description
HSL-3-B M 12/5
HSL-3-B M 12/25
HSL-3-B M 12/50
HSL-3-B M 16/10
HSL-3-B M 16/25
HSL-3-B M 20/30
HSL-3-B M 24/30
20
20
10
10
10
6
4
Description
HSL-3-G M 8/20
HSL-3-G M 10/20
HSL-3-G M 12/25
HSL-3-G M 12/50
HSL-3-G M 16/25
HSL-3-G M 16/50
HSL-3-G M 20/30
HSL-3-G M 20/60
Box qty
40
20
20
10
10
10
6
6
204 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Product features
Type 316 stainless steel
High load capacity
3.3.3.1
Product description
3.3.3.2
Material specifications
3.3.3.3
Technical data
3.3.3.4
Installation instructions
3.3.3.5
Ordering information
Nut
Washer
Minimum
Embedment
Mark
Spacer
Sleeve
Collapsible
Plastic
Section
with anchor
rotation
prevention
Expansion
Sleeve
Stainless steel washer conforms to DIN 17441, 74 ksi futa 103 ksi.
Stainless steel nut conforms to DIN 934.
Cone
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
Setting
information
Symbol
Units
M10
M12
M16
M20
Nominal bit
diameter
dbit
mm
15
18
24
28
mm
75
80
105
130
(in.)
(3)
(3-3/16)
(4-1/8)
(5-1/8)
mm
85
100
125
150
(in.)
(3-3/8)
(4)
(5)
(6)
Minimum nominal
embedment
hnom
Minimum hole
depth
hnom
Minimum fixture
home diameter
dh
Maximum fixture
thickness
tfix
Installation torque
Tinst
Wrench size
Minimum concrete
member thickness
mm
17
20
26
31
(in.)
(11/16)
(13/16)
(1-1/16)
(1-1/4)
mm
20
25
25
30
(in.)
(3/4)
(1)
(1)
(1-1/8)
Nm
55
80
200
400
(ft-lb)
(40)
(60)
(150)
(300)
mm
17
19
24
30
mm
140
160
180
220
(in.)
(5-1/2)
(6-1/4)
(7)
(8-3/4)
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 205
V
c
s = Actual spacing
s min = 1.0 h nom
s cr = 3.0 h ef
Anchor Size
mm
hnom
c
c min
c cr
c min
c cr
=
=
=
=
=
(in.)
M10
75
(3)
M12
80
(3-3/16)
M16
105
(4-1/8)
M20
130
(5-1/8)
h ef - actual embedment
depth
h nom - standard embedment
depth
Tension/Shear
Spacing s
Tension RN
Anchor diameter
mm
(in.)
65
75
(2-1/2)
M10
M12
M16
(3)
.70
80
105
(3-1/8)
.71
.70
(4-1/8)
.76
.74
.70
130
(5-1/8)
.81
.79
.73
155
(6-1/8)
.86
.84
175
(6-7/8)
.90
195
(7-5/8)
.94
225
(8-7/8)
1.0
240
(9-3/8)
275
Edge distance c
M20
mm
(in.)
65
(2-1/2)
Shear RV
Anchor diameter
M10
M12
M16
75
( 3)
.70
80
(3-1/8)
.71
.70
105
(4-1/8)
.78
.76
.70
.70
130
(5-1/8)
.85
.83
.74
.77
.72
155
(6-1/8)
.91
.88
.87
.80
.75
162
(6-3/8)
.93
.91
.82
.77
187
(7-3/8)
1.0
.97
.87
.80
200
(7-7/8)
1.0
.89
.82
225
(10-3/4)
.94
.86
315
(12-3/8)
1.0
350
Anchor diameter
M20
M10
M12
M16
M20
.30
.33
.30
.48
.44
.30
.70
.64
.59
.41
.30
.79
.73
.80
.74
.52
.39
.90
.80
.75
.84
.78
.55
.41
.96
.85
.78
1.0
.92
.66
.50
1.0
.88
.80
1.0
.72
.55
(8-7/8)
.92
.84
.83
.64
265
(10-3/8)
1.0
.91
1.0
.79
.91
275
(10-3/4)
.92
1.0
.82
(13-3/4)
.95
300
(11-3/4)
.96
.91
395
(15-1/2)
1.0
325
(12-3/4)
1.0
1.0
430
(17)
350
(13-3/4)
470
(18-1/2)
390
(15-3/8)
A = 0.15
s
h ef
s cr = 3.0 h ef
+ 0.55
c cr = 2.5 h ef
c 1.0 hnom
+ 0.70
RV = 0.47
c
h nom
c cr = 2.5 h nom
0.17
206 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Anchor
diameter
M10
M12
M16
M20
Shear
kN (lb)
Shear
kN (lb)
Shear
kN (lb)
Shear
kN (lb)
75
6.8
13.7
9.1
14.8
11.5
15.8
11.5
16.4
(3)
(1,535)
(3,090)
(2,055)
(3,325)
(2,575)
(3,560)
(2,595)
(3,690)
80
8.7
20.2
11.3
21.8
13.8
23.3
17.5
25.0
(3-3/16)
(1,960)
(4,540)
(2,530)
(4,890)
(3,105)
(5,245)
(3,925)
(5,615)
105
17.6
34.7
20.9
39.9
24.2
45.0
30.7
46.9
(4-1/8)
(3,965)
(7,805)
(4,705)
(8,965)
(5,450)
(10,125)
(6,900)
(10,550)
130
25.1
52.9
30.7
58.7
36.4
64.5
44.5
64.5
(5-1/8)
(5,650)
(11,900)
(6,910)
(13,195)
(8,175)
(14,490)
(10,005)
(14,490)
Nominal
embedment
mm (in.)
M10
M12
M16
M20
Shear
kN (lb)
Shear
kN (lb)
Shear
kN (lb)
Shear
kN (lb)
75
23.8
47.8
31.9
51.6
40.0
55.2
40.3
57.3
(3)
(5,350)
(10,785)
(7,165)
(11,595)
(8,985)
(12,410)
(9,055)
(12,880)
80
30.4
70.5
39.3
75.9
48.2
81.4
60.9
87.1
(3-3/16)
(6,830)
(15,845)
(8,830)
(17,070)
(10,835)
(18,300)
(13,700)
(19,590)
105
61.6
121.1
73.0
139.1
84.5
157.1
107.0
163.7
(4-1/8)
(13,840)
(27,220)
(16,420)
(31,270)
(19,005)
(35,320)
(24,065)
(36,800)
130
87.7
184.7
107.3
204.7
126.9
224.8
155.3
224.8
(5-1/8)
(19,715)
(41,510)
(24,115)
(46,025)
(28,520)
(50,540)
(34,910)
(50,540)
( ) ( )
Nd
5/3
N rec
Vd
Vrec
5/3
3.3.2
3.3.3
3.3.1
1.0
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online
at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU
are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti
Technical Services for applications and conditions not addressed in the IFU.
3.3.9
3.3.9
Box qty
M 10/20
20
M 12/25
20
M 16/25
10
M 20/30
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 207
Product description
3.3.4.2
Material specifications
3.3.4.3
Technical data
3.3.4.4
Installation instructions
3.3.4.5
Ordering information
Product features
Passed Telecordia NEBS GR-63CORE Zone 4 earthquake level
qualification testing
High load capacity in thin slabs
Force controlled expansion
Guide specifications
Expansion anchors HSL-I M12 65/80
internally threaded, carbon steel
expansion anchor consists of expansion
sleeve, cone and spacer sleeve,
threaded rod, torque nut and washer.
Anchor shall be torque controlled
expansion anchor manufactured by Hilti.
208 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Units
Setting information
dbit
mm
18
Minimum nominal
embedment
hnom
hnom
dh
tfix
Installation torque
Tinst
Wrench size
Minimum concrete member
thickness
mm
65
80
(in.)
(2-9/16)
(3-3/16)
mm
80
95
(in.)
(3-3/16)
(3-3/4)
mm
14
(in.)
(9/16)
mm
40
25
(in.)
(1-9/16)
(1)
Nm
80
(ft-lb)
(60)
mm
19
3.3.1
3.3.2
3.3.3
3.3.4
mm
115
130
(in.)
(4-1/2)
(5)
3.3.5
3.3.6
Description
Anchor length
mm
Nominal
embedment
mm
Tension
lb
Shear
lb
113
65
2,335
2,265
130
80
3,150
2,350
3.3.7
1
2
3.3.8
3.3.9
3.3.7
3.3.7
( ) ( )
Nd
N rec
5/3
Vd
Vrec
5/3
3.3.7
1.0
3.3.7
3.3.7
3.3.7
Box qty
20
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 209
Notes
210 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.5.1
Product description
Product features
3.3.5.2
Material specifications
3.3.5.3
Technical data
3.3.5.4
Installation instructions
3.3.5.5
Ordering information
Guide specifications
Impact section
dog point
3.3.1
Nut
Washer
3.3.2
3.3.3
Red
mark
3.3.4
Anchor
thread
3.3.6
3.3.5
3.3.7
3.3.8
Anchor
body
3.3.9
3.3.9
3.3.9
Stainless
steel
expansion
sleeve
(wedges)
Expansion
cone
3.3.9
3.3.9
3.3.9
3.3.9
Listings/Approvals
ICC-ES (International Code Council)
ESR-1917
City of Los Angeles
Research Report No. 25701
FM (Factory Mutual)
Pipe Hanger Components for Automatic
Sprinkler Systems for 3/8 through 3/4
UL LLC
Pipe Hanger Equipment for Fire
Protection Services for 3/8 through 3/4
Shear
(lb)
NA
7,419
11,465
17,535
Tension
(lb)
6,744
11,240
17,535
25,853
Carbon steel anchor components plated in accordance with ASTM B633 to a minimum thickness of 5 m.
Nuts conform to the requirements of ASTM A563, Grade A, Hex.
Washers meet the requirements of ASTM F844.
Expansion sleeves (wedges) are manufactured from type 316 stainless steel
Stainless steel
Stainless steel KB-TZ anchors are made of type 304 or 316 material and have the following minimum bolt fracture loads.
Anchor diameter
(in.)
Shear
(lb)
Tension
(lb)
3/8
1/2
5/8
3/4
5,058
8,543
13,938
22,481
6,519
12,364
19,109
24,729
All nuts and washers are made from type 304 or type 316 stainless steel respectively.
Nuts meet the dimensional requirements of ASTM F594.
Washers meet the dimensional requirements of ANSI B18.22.1, Type A, plain.
Expansion sleeve (wedges) are made from type 316 stainless steel.
1 Bolt fracture loads are determined by testing in a universal tensile machine for quality control at the manufacturing facility. These loads are
not intended for design purposes. See tables 4 and 16 for the steel design strengths of carbon steel and stainless steel, respectively.
212 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
dbit
Minimum nominal
embedment
hnom
Effective minimum
embedment
hef
ho
tmin
tmax
Installation torque
Tinst
3/8
1/2
5/8
3/4
in.
3/8
1/2
5/8
3/4
Symbol Units
dh
anch
Threaded length
including dog point
thread
Unthreaded length
unthr
in.
2-5/16
2-3/8
3-5/8
3-9/16
4-7/16
4-5/16
(mm)
(59)
(60)
(91)
(91)
(113)
(110)
5-9/16
(142)
in.
3-1/4
3-1/8
3-3/4
4-3/4
(mm)
(51)
(51)
(83)
(79)
(102)
(95)
(121)
in.
2-5/8
2-5/8
3-3/4
4-3/4
4-5/8
5-3/4
(mm)
(67)
(67)
(102)
(95)
(121)
(117)
(146)
in.
1/8
1/8
(mm)
(3)
(3)
1/8
n/a
1/8
n/a
(3)
(3)
n/a
3.3.1
3.3.2
in.
2-1/4
2-3/4
5-5/8
4-3/4
4-5/8
3-5/8
(mm)
(57)
(101)
(70)
(143)
(121)
(117)
(92)
ft-lb
25
40
60
110
(Nm)
(34)
(54)
(81)
(149)
in.
7/16
9/16
11/16
13/16
(mm)
(11.1)
(14.3)
(17.5)
(20.6)
in.
3-3/4
(mm)
(76)
(95)
(127)
in.
7/8
(mm)
(22)
(114)
(140)
(41)
(73)
(41)
(60)
(86)
3.3.4
3.3.5
4-3/4
8-1/2
10
5-1/2
10
(178)
(121)
(152)
(216)
(254)
(140)
(203)
(254)
1-5/8 2-7/8 1-5/8 2-3/8 3-3/8 4-7/8 1-1/2 2-3/4 5-1/4 6-3/4 1-1/2
(178)
(38)
(70)
(133)
(171)
(38)
(102)
(152)
in.
2-1/8
2-1/8
3-1/4
(mm)
(54)
(54)
(83)
(102)
3.3.3
1 Minimum thickness of fixture is a concern only when the anchor is installed at the minimum nominal embedment. When KWIK Bolt TZ anchors are installed at
this embedment, the anchor threading ends near the surface of the concrete. If the fixture is sufficiently thin, it could be possible to run the nut to the bottom of
the threading during application of the installation torque. If fixtures are thin, it is recommended that embedment be increased accordingly.
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 213
Tension - Nn
1,635
1,790
2,070
2,535
2,375
2,605
3,005
3,680
3/8
1/2
5/8
3/4
2-5/16
(51)
(59)
(7.3)
(8.0)
(9.2)
(11.3)
(10.6)
(11.6)
(13.4)
(16.4)
2-3/8
2,205
2,415
2,790
3,420
2,375
2,605
3,005
3,680
(51)
(60)
(9.8)
(10.7)
(12.4)
(15.2)
(10.6)
(11.6)
(13.4)
(16.4)
3-1/4
3-5/8
3,585
3,925
4,535
5,555
9,845
10,785
12,450
15,250
(83)
(91)
(15.9)
(17.5)
(20.2)
(24.7)
(43.8)
(48.0)
(55.4)
(67.8)
3-1/8
3-9/16
4,310
4,720
5,450
6,675
9,280
10,165
11,740
14,380
(79)
(91)
(19.2)
(21.0)
(24.2)
(29.7)
(41.3)
(45.2)
(52.2)
(64.0)
4-7/16
5,945
6,510
7,520
9,210
13,440
14,725
17,000
20,820
(102)
(113)
(26.4)
(29.0)
(33.5)
(41.0)
(59.8)
(65.5)
(75.6)
(92.6)
3-3/4
4-5/16
5,380
5,895
6,810
8,340
12,200
13,365
15,430
18,900
(95)
(110)
(23.9)
(26.2)
(30.3)
(37.1)
(54.3)
(59.5)
(68.6)
(84.1)
4-3/4
5-9/16
6,940
7,605
8,780
10,755
17,390
19,050
22,000
26,945
(121)
(142)
(30.9)
(33.8)
(39.1)
(47.8)
(77.4)
(84.7)
(97.9)
(119.9)
Table 3 - Hilti KWIK Bolt TZ carbon steel design strength with concrete / pullout failure in cracked concrete1,2,3,4,5
Tension - Nn
Shear - Vn
Nominal Effective Nominal
anchor embed. embed. 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
diameter in. (mm) in. (mm)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
3/8
1/2
5/8
3/4
2-5/16
1,475
1,615
1,865
2,285
1,685
1,845
2,130
2,605
(51)
(59)
(6.6)
(7.2)
(8.3)
(10.2)
(7.5)
(8.2)
(9.5)
(11.6)
2-3/8
1,565
1,710
1,975
2,420
1,685
1,845
2,130
2,605
(51)
(60)
(7.0)
(7.6)
(8.8)
(10.8)
(7.5)
(8.2)
(9.5)
(11.6)
3-1/4
3-5/8
3,195
3,500
4,040
4,950
6,970
7,640
8,820
10,800
(83)
(91)
(14.2)
(15.6)
(18.0)
(22.0)
(31.0)
(34.0)
(39.2)
(48.0)
3-1/8
3-9/16
3,050
3,345
3,860
4,730
6,575
7,200
8,315
10,185
(79)
(91)
(13.6)
(14.9)
(17.2)
(21.0)
(29.2)
(32.0)
(37.0)
(45.3)
4-7/16
4,420
4,840
5,590
6,845
9,520
10,430
12,040
14,750
(102)
(113)
(19.7)
(21.5)
(24.9)
(30.4)
(42.3)
(46.4)
(53.6)
(65.6)
3-3/4
4-5/16
4,010
4,395
5,075
6,215
8,640
9,465
10,930
13,390
(95)
(110)
(17.8)
(19.5)
(22.6)
(27.6)
(38.4)
(42.1)
(48.6)
(59.6)
4-3/4
5-9/16
5,720
6,265
7,235
8,860
12,320
13,495
15,585
19,085
(121)
(142)
(25.4)
(27.9)
(32.2)
(39.4)
(54.8)
(60.0)
(69.3)
(84.9)
214 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Tensile3 Nsa
lb (kN)
Shear4 Vsa
lb (kN)
4,875
2,335
1,465
(21.7)
(10.4)
(6.5)
8,030
3,570
3,570
(35.7)
(15.9)
(15.9)
12,880
5,260
4,940
(57.3)
(23.4)
(22.0)
18,840
8,890
7,635
(83.8)
(39.5)
(34.0)
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
Figure 2
3.3.7
cmin,2
Case 2
Case 1
spacing s
3.3.9
cmin,1 at smin,1
3.3.9
sdesign
cmin,1
smin,2
cmin,2 at smin,2
Concrete
Edge
smin,1
3.3.8
cdesign
edge distance c
3.3.9
3.3.9
3.3.9
Setting
information
Symbol
Effective minimum
embedment
hef
hmin
Case 1
Case 2
cmin,1
for
smin,1
cmin,2
for
smin,2
1/2
3.3.9
Units
3/8
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
2
(51)
2
(51)
3-1/4
(83)
5/8
4
5
(102)
(127)
2-1/2
(64)
5
(127)
3-5/8
(92)
2-1/2
(64)
4
6
(102)
(152)
2-3/4
(70)
5-3/4
(146)
4-1/8
(105)
2-3/4
(70)
6
8
(152)
(203)
2-3/8
(60)
5-3/4
(146)
3-1/2
(89)
2-3/8
(60)
3-1/8
(79)
5
(127)
3-5/8
(92)
6-1/8
(156)
4-3/4
(121)
3-1/2
(89)
3/4
4
(102)
3-3/4
(95)
6
8
(152)
(203)
3-1/4
(83)
5-7/8
(149)
4-1/4
(108)
3
(76)
6
8
(152)
(203)
4-3/4
(121)
10-1/2
(267)
9-1/2
(241)
5
(127)
4-3/4
(121)
8
(203)
4-1/8
(105)
8-7/8
(225)
7-3/4
(197)
4
(102)
3.3.9
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge distance c, where cmin,1 < c < cmin,2, will determine the permissible spacings.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 215
3/8-in. KB-TZ CS
uncracked concrete
Effective
embed. hef
Nominal
embed. hnom
2-1/2
3
3-1/2
3-5/8
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
in.
(mm)
in.
(mm)
(64)
(76)
(89)
(92)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
Spacing
factor
in tension
AN
Edge
distance
factor in
tension
RN
Spacing
factor
in shear3
AV
II To edge
RV
Conc.
thickness
factor in
shear4
HV
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2-5/16
(59)
0.71
0.75
0.79
0.80
0.83
0.88
0.92
0.96
1.00
2-5/16
(59)
0.60
0.69
0.80
0.83
0.91
1.00
2-5/16
(59)
0.60
0.62
0.64
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.87
0.91
0.95
1.00
2-5/16
(59)
0.49
0.64
0.81
0.85
0.99
1.00
2-5/16
(59)
0.60
0.69
0.81
0.85
0.99
1.00
2-5/16
(59)
n/a
n/a
n/a
n/a
0.81
0.86
0.91
0.95
1.00
Table 7 - Load adjustment factors for 3/8-in. diameter carbon steel KWIK Bolt TZ
in cracked concrete1,2
3/8-in. KB-TZ CS
cracked concrete
Effective
embed. hef
Nominal
embed. hnom
2-1/2
3
3-1/2
3-5/8
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
in.
(mm)
in.
(mm)
(64)
(76)
(89)
(92)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
Spacing
factor
in tension
AN
Edge
distance
factor in
tension
RN
Spacing
factor
in shear3
AV
II To edge
RV
Conc.
thickness
factor in
shear4
HV
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2-5/16
(59)
0.71
0.75
0.79
0.80
0.83
0.88
0.92
0.96
1.00
2-5/16
(59)
0.87
1.00
1.00
1.00
2-5/16
(59)
0.60
0.62
0.65
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.87
0.92
0.96
1.00
2-5/16
(59)
0.49
0.65
0.82
0.86
1.00
1.00
2-5/16
(59)
0.87
1.00
1.00
1.00
2-5/16
(59)
n/a
n/a
n/a
n/a
0.82
0.87
0.91
0.96
1.00
216 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Effective
embed. hef
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2-3/8
3-5/8
2-3/8
3-5/8
2-3/8
3-5/8
2-3/8
3-5/8
2-3/8
3-5/8
2-3/8
3-5/8
Nominal
embed. hnom
2-3/8
2-1/2
2-3/4
3
3-1/2
4
4-1/8
4-1/2
5
5-1/2
5-3/4
6
7
8
9
10
11
12
14
16
18
> 20
in.
(mm)
in.
(mm)
(60)
(64)
(70)
(76)
(89)
(102)
(105)
(114)
(127)
(140)
(146)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(60)
n/a
n/a
0.73
0.75
0.79
0.83
0.84
0.88
0.92
0.96
0.98
1.00
(92)
0.62
0.63
0.64
0.65
0.68
0.71
0.71
0.73
0.76
0.78
0.79
0.81
0.86
0.91
0.96
1.00
Edge distance
factor in tension
RN
(60)
n/a
n/a
0.51
0.55
0.64
0.73
0.75
0.82
0.91
1.00
(92)
0.41
0.42
0.44
0.46
0.51
0.56
0.57
0.61
0.67
0.73
0.77
0.80
0.93
1.00
Spacing factor
in shear3
AV
1/2-in. KB-TZ CS
uncracked concrete
(60)
n/a
n/a
0.62
0.63
0.65
0.68
0.68
0.70
0.72
0.74
0.75
0.76
0.81
0.85
0.89
0.94
0.98
1.00
(92)
0.54
0.55
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.60
0.61
0.63
0.64
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
toward edge
RV
(60)
n/a
n/a
0.51
0.55
0.64
0.73
0.75
0.82
0.91
1.00
(92)
0.13
0.14
0.16
0.19
0.23
0.29
0.30
0.34
0.40
0.46
0.49
0.53
0.66
0.81
0.97
1.00
II to edge
RV
(60)
n/a
n/a
0.51
0.55
0.64
0.73
0.75
0.82
0.91
1.00
(92)
0.26
0.28
0.33
0.37
0.47
0.56
0.57
0.61
0.67
0.73
0.77
0.80
0.93
1.00
Conc. thickness
factor in shear4
HV
(60)
n/a
n/a
n/a
n/a
n/a
0.84
0.85
0.89
0.94
0.98
1.00
(92)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.89
0.93
1.00
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
2-3/8
2-1/2
2-3/4
3
3-1/2
4
4-1/8
4-1/2
5
5-1/2
5-3/4
6
7
8
9
10
11
12
14
16
18
> 20
in.
(mm)
in.
(mm)
(60)
(64)
(70)
(76)
(89)
(102)
(105)
(114)
(127)
(140)
(146)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Table 9 - Load adjustment factors for 1/2-in. diameter carbon steel KWIK Bolt TZ in cracked concrete1,2
1/2-in. KB-TZ CS
cracked concrete
3.3.1
II to edge
RV
Conc. thickness
factor in shear4
HV
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
n/a
n/a
0.73
0.75
0.79
0.83
0.84
0.88
0.92
0.96
0.98
1.00
0.62
0.63
0.64
0.65
0.68
0.71
0.71
0.73
0.76
0.78
0.79
0.81
0.86
0.91
0.96
1.00
n/a
n/a
0.93
1.00
1.00
1.00
1.00
0.63
0.65
0.68
0.71
0.79
0.86
0.88
0.94
1.00
n/a
n/a
0.62
0.63
0.65
0.68
0.68
0.70
0.72
0.74
0.75
0.76
0.81
0.85
0.90
0.94
0.98
1.00
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.60
0.60
0.61
0.63
0.65
0.66
0.68
0.70
0.72
0.76
0.79
0.83
0.86
n/a
n/a
0.62
0.71
0.89
1.00
1.00
0.13
0.14
0.16
0.19
0.24
0.29
0.30
0.34
0.40
0.47
0.50
0.53
0.67
0.82
0.98
1.00
n/a
n/a
0.93
1.00
1.00
1.00
1.00
0.26
0.29
0.33
0.38
0.47
0.58
0.61
0.69
0.81
0.93
1.00
1.00
n/a
n/a
n/a
n/a
n/a
0.84
0.85
0.89
0.94
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.90
0.94
1.00
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 217
Spacing factor
in tension
AN
Effective
embed. hef
3-1/8
(79)
4
(102)
3-1/8
(79)
3-9/16
(90)
4-7/16
(113)
n/a
n/a
0.69
0.69
0.71
0.73
0.74
0.75
0.77
0.79
0.81
0.82
0.83
0.93
1.00
0.63
0.64
0.65
0.65
0.67
0.68
0.69
0.70
0.71
0.73
0.74
0.75
0.76
0.83
0.92
1.00
Nominal
embed. hnom
3
3-1/4
3-1/2
3-5/8
4
4-1/4
4-1/2
4-3/4
5
5-1/2
5-7/8
6
6-1/8
8
10
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(76)
(83)
(89)
(92)
(102)
(108)
(114)
(121)
(127)
(140)
(149)
(152)
(156)
(203)
(254)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
toward edge
RV
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
n/a
n/a
n/a
0.60
0.64
0.67
0.70
0.73
0.77
0.85
0.90
0.92
0.94
1.00
n/a
0.46
0.48
0.48
0.51
0.53
0.56
0.58
0.60
0.64
0.67
0.69
0.70
0.91
1.00
n/a
n/a
0.57
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.62
0.62
0.66
0.70
0.74
0.77
0.81
0.85
0.89
0.93
0.97
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.59
0.59
0.60
0.63
0.66
0.69
0.72
0.75
0.78
0.82
0.85
0.88
n/a
n/a
n/a
0.28
0.32
0.35
0.38
0.42
0.45
0.52
0.57
0.59
0.61
0.91
1.00
n/a
0.17
0.19
0.20
0.23
0.26
0.28
0.30
0.33
0.38
0.42
0.43
0.44
0.66
0.92
1.00
n/a
n/a
n/a
0.56
0.64
0.67
0.70
0.73
0.77
0.85
0.90
0.92
0.94
1.00
n/a
0.34
0.38
0.40
0.47
0.51
0.56
0.58
0.60
0.64
0.67
0.69
0.70
0.91
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.66
0.68
0.69
0.69
0.79
0.89
0.97
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.62
0.71
0.80
0.87
0.94
1.00
II to edge
RV
Conc. thickness
factor in shear4
HV
Table 11 - Load adjustment factors for 5/8-in. diameter carbon steel KWIK Bolt TZ in cracked concrete1,2
5/8-in. KB-TZ CS
cracked concrete
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
3
3-1/4
3-1/2
3-5/8
4
4-1/4
4-1/2
4-3/4
5
5-1/2
5-7/8
6
6-1/8
8
10
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(76)
(83)
(89)
(92)
(102)
(108)
(114)
(121)
(127)
(140)
(149)
(152)
(156)
(203)
(254)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
toward edge
RV
II to edge
RV
Conc. thickness
factor in shear4
HV
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
n/a
n/a
0.69
0.69
0.71
0.73
0.74
0.75
0.77
0.79
0.81
0.82
0.83
0.93
1.00
0.63
0.64
0.65
0.65
0.67
0.68
0.69
0.70
0.71
0.73
0.74
0.75
0.76
0.83
0.92
1.00
n/a
n/a
n/a
0.83
0.89
0.93
0.97
1.00
n/a
0.66
0.69
0.71
0.75
0.78
0.81
0.84
0.87
0.93
0.98
1.00
n/a
n/a
0.57
0.57
0.58
0.58
0.59
0.59
0.60
0.61
0.62
0.62
0.62
0.66
0.70
0.74
0.78
0.82
0.85
0.89
0.93
0.97
0.55
0.55
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.59
0.59
0.60
0.60
0.63
0.66
0.69
0.72
0.75
0.79
0.82
0.85
0.88
n/a
n/a
n/a
0.28
0.33
0.36
0.39
0.42
0.45
0.52
0.58
0.60
0.62
0.92
1.00
n/a
0.17
0.19
0.20
0.24
0.26
0.28
0.31
0.33
0.38
0.42
0.43
0.45
0.67
0.93
1.00
n/a
n/a
n/a
0.56
0.65
0.71
0.78
0.84
0.91
1.00
n/a
0.35
0.39
0.41
0.47
0.52
0.56
0.61
0.66
0.76
0.84
0.87
0.89
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.66
0.68
0.69
0.69
0.79
0.89
0.97
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.62
0.71
0.80
0.87
0.94
1.00
218 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in tension
AN
Effective
embed. hef
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-5/16
(110)
5-9/16
(141)
n/a
n/a
n/a
n/a
0.72
0.74
0.77
0.81
0.84
0.86
0.89
0.92
0.94
0.97
1.00
0.64
0.64
0.66
0.67
0.68
0.69
0.71
0.75
0.77
0.78
0.81
0.83
0.85
0.87
0.92
0.99
1.00
Nominal
embed. hnom
4
4-1/8
4-1/2
4-3/4
5
5-1/2
6
7
7-3/4
8
8-7/8
9-1/2
10
10-1/2
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(102)
(105)
(114)
(121)
(127)
(140)
(152)
(178)
(197)
(203)
(225)
(241)
(254)
(267)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
toward edge
RV
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(142)
n/a
n/a
n/a
0.49
0.51
0.55
0.60
0.70
0.78
0.80
0.89
0.95
1.00
n/a
0.55
0.57
0.59
0.61
0.65
0.69
0.78
0.86
0.89
0.99
1.00
n/a
n/a
n/a
n/a
0.59
0.60
0.60
0.62
0.63
0.64
0.65
0.66
0.67
0.68
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.56
0.56
0.56
0.57
0.57
0.58
0.58
0.60
0.61
0.61
0.63
0.63
0.64
0.65
0.67
0.70
0.73
0.75
0.78
0.81
0.84
n/a
n/a
n/a
0.35
0.38
0.43
0.49
0.62
0.72
0.76
0.89
0.98
1.00
n/a
0.21
0.24
0.26
0.28
0.32
0.36
0.46
0.53
0.56
0.65
0.72
0.78
0.84
1.00
n/a
n/a
n/a
0.49
0.51
0.55
0.60
0.70
0.78
0.80
0.89
0.98
1.00
n/a
0.41
0.47
0.51
0.55
0.64
0.69
0.78
0.86
0.89
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.70
0.73
0.75
0.78
0.81
0.83
0.85
0.91
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.71
0.73
0.75
0.77
0.82
0.89
0.95
1.00
II to edge
RV
Conc. thickness
factor in shear4
HV
3/4-in. KB-TZ CS
cracked concrete
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
4
4-1/8
4-1/2
4-3/4
5
5-1/2
6
7
7-3/4
8
8-7/8
9-1/2
10
10-1/2
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(102)
(105)
(114)
(121)
(127)
(140)
(152)
(178)
(197)
(203)
(225)
(241)
(254)
(267)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Edge distance
factor in tension
RN
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
Table 13 - Load adjustment factors for 3/4-in. diameter carbon steel KWIK Bolt TZ in cracked concrete1,2
Spacing factor
in tension
AN
3.3.1
Spacing factor
in shear3
AV
toward edge
RV
II to edge
RV
3.3.9
Conc. thickness
factor in shear4
HV
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(142)
n/a
n/a
n/a
n/a
0.72
0.74
0.77
0.81
0.84
0.86
0.89
0.92
0.94
0.97
1.00
0.64
0.64
0.66
0.67
0.68
0.69
0.71
0.75
0.77
0.78
0.81
0.83
0.85
0.87
0.92
0.99
1.00
n/a
n/a
n/a
0.88
0.91
0.98
1.00
1.00
1.00
1.00
1.00
1.00
n/a
0.69
0.73
0.75
0.77
0.83
0.88
0.99
1.00
n/a
n/a
n/a
n/a
0.59
0.60
0.60
0.62
0.64
0.64
0.65
0.67
0.67
0.68
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.56
0.56
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.61
0.63
0.64
0.64
0.65
0.67
0.70
0.73
0.76
0.78
0.81
0.84
n/a
n/a
n/a
0.35
0.38
0.44
0.50
0.63
0.73
0.77
0.90
0.99
1.00
n/a
0.21
0.24
0.26
0.28
0.32
0.37
0.46
0.54
0.56
0.66
0.73
0.79
0.85
1.00
n/a
n/a
n/a
0.70
0.76
0.87
1.00
1.00
1.00
1.00
1.00
1.00
n/a
0.42
0.48
0.52
0.56
0.64
0.73
0.92
1.00
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.70
0.74
0.75
0.79
0.81
0.84
0.86
0.92
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.71
0.74
0.75
0.77
0.83
0.89
0.95
1.00
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 219
1/2
5/8
3/4
2-5/16
1,710
1,875
2,160
2,650
2,375
2,605
3,005
3,680
(51)
(59)
(7.6)
(8.3)
(9.6)
(11.8)
(10.6)
(11.6)
(13.4)
(16.4)
2-3/8
1,865
2,045
2,360
2,890
2,375
2,605
3,005
3,680
(51)
(60)
(8.3)
(9.1)
(10.5)
(12.9)
(10.6)
(11.6)
(13.4)
(16.4)
3-1/4
3-5/8
3,745
4,100
4,735
5,800
9,845
10,785
12,450
15,250
(83)
(91)
(16.7)
(18.2)
(21.1)
(25.8)
(43.8)
(48.0)
(55.4)
(67.8)
3-1/8
3-9/16
4,310
4,720
5,450
6,675
9,280
10,165
11,740
14,380
(79)
(91)
(19.2)
(21.0)
(24.2)
(29.7)
(41.3)
(45.2)
(52.2)
(64.0)
4-7/16
6,240
6,835
7,895
9,665
13,440
14,725
17,000
20,820
(102)
(113)
(27.8)
(30.4)
(35.1)
(43.0)
(59.8)
(65.5)
(75.6)
(92.6)
3-3/4
4-5/16
5,665
6,205
7,165
8,775
12,200
13,365
15,430
18,900
(95)
(110)
(25.2)
(27.6)
(31.9)
(39.0)
(54.3)
(59.5)
(68.6)
(84.1)
4-3/4
5-9/16
7,825
8,575
9,900
12,125
17,390
19,050
22,000
26,945
(121)
(142)
(34.8)
(38.1)
(44.0)
(53.9)
(77.4)
(84.7)
(97.9)
(119.9)
Table 15 - Hilti KWIK Bolt TZ stainless steel design strength with concrete / pullout failure in cracked concrete1,2,3,4,5
Tension - Nn
Shear - Vn
Nominal Effective Nominal
anchor embed. embed. 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
diameter in. (mm) in. (mm)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
3/8
1/2
5/8
3/4
2-5/16
1,520
1,665
1,925
2,355
1,685
1,845
2,130
2,605
(51)
(59)
(6.8)
(7.4)
(8.6)
(10.5)
(7.5)
(8.2)
(9.5)
(11.6)
2-3/8
1,750
1,915
2,210
2,710
2,375
2,605
3,005
3,680
(51)
(60)
(7.8)
(8.5)
(9.8)
(12.1)
(10.6)
(11.6)
(13.4)
(16.4)
3-1/4
3-5/8
3,235
3,545
4,095
5,015
6,970
7,640
8,820
10,800
(83)
(91)
(14.4)
(15.8)
(18.2)
(22.3)
(31.0)
(34.0)
(39.2)
(48.0)
3-1/8
3-9/16
3,050
3,345
3,860
4,730
6,575
7,200
8,315
10,185
(79)
(91)
(13.6)
(14.9)
(17.2)
(21.0)
(29.2)
(32.0)
(37.0)
(45.3)
4-7/16
3,795
4,160
4,800
5,880
9,520
10,430
12,040
14,750
(102)
(113)
(16.9)
(18.5)
(21.4)
(26.2)
(42.3)
(46.4)
(53.6)
(65.6)
3-3/4
4-5/16
5,270
5,775
6,670
8,165
12,200
13,365
15,430
18,900
(95)
(110)
(23.4)
(25.7)
(29.7)
(36.3)
(54.3)
(59.5)
(68.6)
(84.1)
4-3/4
5-9/16
5,720
6,265
7,235
8,860
12,320
13,495
15,585
19,085
(121)
(142)
(25.4)
(27.9)
(32.2)
(39.4)
(54.8)
(60.0)
(69.3)
(84.9)
220 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Tensile3 Nsa
lb (kN)
Shear4 Vsa
lb (kN)
4,475
3,070
1,835
(19.9)
(13.7)
(8.2)
8,665
4,470
4,470
(38.5)
(19.9)
(19.9)
13,410
6,415
6,080
(59.7)
(28.5)
(27.0)
18,040
10,210
8,380
(80.2)
(45.4)
(37.3)
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
Figure 3
3.3.7
cmin,2
Case 2
Case 1
spacing s
3.3.9
cmin,1 at smin,1
3.3.9
sdesign
cmin,1
smin,2
cmin,2 at smin,2
Concrete
Edge
smin,1
3.3.8
cdesign
edge distance c
3.3.9
3.3.9
3.3.9
Setting
information
Symbol
Effective minimum
embedment1
hef
hmin
Case 1
Case 2
cmin,1
for
smin,1
cmin,2
for
smin,2
Units
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
1/2
3.3.9
3/8
2
(51)
2
(51)
3-1/4
(83)
5/8
4
5
(102)
(127)
2-1/2
(64)
5
(127)
3-1/2
(89)
2-1/4
(57)
4
6
(102)
(152)
2-7/8
(73)
5-3/4
(146)
4-1/2
(114)
2-7/8
(73)
6
8
(152)
(203)
2-1/8
(54)
5-1/4
(133)
3-1/4
(83)
2
(51)
3-1/8
(79)
5
(127)
3-1/4
(83)
5-1/2
(140)
4-1/8
(105)
2-3/4
(70)
3/4
4
(102)
6
8
(152)
(203)
2-3/8
(60)
5-1/2
(140)
4-1/4
(108)
2-3/8
(60)
3-3/4
(95)
6
(152)
4-1/4
(108)
10
(254)
9-1/2
(241)
5
(127)
4-3/4
(121)
3.3.9
8
(203)
4
(102)
8-1/2
(216)
7
(178)
4
(102)
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge distance c, where cmin,1 < c < cmin,2, will determine the permissible spacings.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 221
3/8-in. KB-TZ SS
uncracked concrete
Effective
embed. hef
Nominal
embed. hnom
2-1/4
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
in.
(mm)
in.
(mm)
(57)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
Spacing
factor
in tension
AN
Edge
distance
factor in
tension
RN
Spacing
factor
in shear3
AV
II to edge
RV
Conc.
thickness
factor in
shear4
HV
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2-5/16
(59)
0.69
0.71
0.75
0.79
0.83
0.88
0.92
0.96
1.00
2-5/16
(59)
n/a
0.60
0.69
0.80
0.91
1.00
2-5/16
(59)
0.59
0.60
0.62
0.64
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.87
0.91
0.95
1.00
2-5/16
(59)
n/a
0.49
0.64
0.81
0.99
1.00
2-5/16
(59)
n/a
0.60
0.69
0.81
0.99
1.00
2-5/16
(59)
n/a
n/a
n/a
n/a
0.81
0.86
0.91
0.95
1.00
Table 19 - Load Adjustment Factors for 3/8-in. Diameter Stainless Steel KWIK Bolt TZ
in Cracked Concrete1,2
3/8-in. KB-TZ SS
cracked concrete
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
2-1/4
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
in.
(mm)
in.
(mm)
(57)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
Spacing
factor
in tension
AN
Edge
distance
factor in
tension
RN
Spacing
factor
in shear3
AV
II to edge
RV
Conc.
thickness
factor in
shear4
HV
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2
(51)
2-5/16
(59)
0.69
0.71
0.75
0.79
0.83
0.88
0.92
0.96
1.00
2-5/16
(59)
n/a
0.87
1.00
1.00
2-5/16
(59)
0.59
0.60
0.62
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.87
0.92
0.96
1.00
2-5/16
(59)
n/a
0.49
0.65
0.82
1.00
2-5/16
(59)
n/a
0.87
1.00
1.00
2-5/16
(59)
n/a
n/a
n/a
n/a
0.82
0.87
0.91
0.96
1.00
222 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Effective
embed. hef
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
n/a
n/a
0.74
0.75
0.77
0.79
0.83
0.88
0.92
0.94
0.96
1.00
0.60
0.61
0.65
0.65
0.67
0.68
0.71
0.73
0.76
0.77
0.78
0.81
0.86
0.91
0.96
1.00
n/a
n/a
0.53
0.55
0.59
0.64
0.73
0.82
0.91
0.95
1.00
n/a
0.39
0.45
0.46
0.49
0.51
0.56
0.61
0.67
0.70
0.73
0.80
0.93
1.00
n/a
n/a
0.63
0.63
0.64
0.65
0.68
0.70
0.72
0.73
0.74
0.76
0.81
0.85
0.89
0.94
0.98
1.00
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.63
0.64
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
n/a
n/a
0.53
0.55
0.59
0.64
0.73
0.82
0.91
0.95
1.00
n/a
0.11
0.17
0.19
0.21
0.23
0.29
0.34
0.40
0.43
0.46
0.53
0.66
0.81
0.97
1.00
n/a
n/a
0.53
0.55
0.59
0.64
0.73
0.82
0.91
0.95
1.00
n/a
0.22
0.35
0.37
0.42
0.47
0.56
0.61
0.67
0.70
0.73
0.80
0.93
1.00
n/a
n/a
n/a
n/a
n/a
n/a
0.84
0.89
0.94
0.96
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.89
0.93
1.00
Nominal
embed. hnom
2
2-1/8
2-7/8
3
3-1/4
3-1/2
4
4-1/2
5
5-1/4
5-1/2
6
7
8
9
10
11
12
14
16
18
> 20
in.
(mm)
in.
(mm)
(51)
(54)
(73)
(76)
(83)
(89)
(102)
(114)
(127)
(133)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
1/2-in. KB-TZ SS
uncracked concrete
toward edge
RV
II to edge
RV
Conc. thickness
factor in shear4
HV
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
2
2-1/8
2-7/8
3
3-1/4
3-1/2
4
4-1/2
5
5-1/4
5-1/2
6
7
8
9
10
11
12
14
16
18
> 20
in.
(mm)
in.
(mm)
(51)
(54)
(73)
(76)
(83)
(89)
(102)
(114)
(127)
(133)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Table 21 - Load adjustment factors for 1/2-in. diameter stainless steel KWIK Bolt TZ in cracked concrete1,2
1/2-in. KB-TZ SS
cracked concrete
3.3.1
II to edge
RV
Conc. thickness
factor in shear4
HV
3.3.9
3.3.9
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2
(51)
3-1/4
(83)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
2-3/8
(60)
3-5/8
(92)
3.3.9
n/a
n/a
0.74
0.75
0.77
0.79
0.83
0.88
0.92
0.94
0.96
1.00
0.60
0.61
0.65
0.65
0.67
0.68
0.71
0.73
0.76
0.77
0.78
0.81
0.86
0.91
0.96
1.00
n/a
n/a
0.97
1.00
1.00
1.00
1.00
1.00
n/a
0.60
0.70
0.71
0.75
0.79
0.86
0.94
1.00
n/a
n/a
0.60
0.60
0.61
0.62
0.64
0.66
0.67
0.68
0.69
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.99
1.00
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.63
0.65
0.66
0.68
0.70
0.72
0.76
0.79
0.83
0.86
n/a
n/a
0.47
0.50
0.56
0.63
0.77
0.92
1.00
n/a
0.11
0.18
0.19
0.21
0.24
0.29
0.34
0.40
0.43
0.47
0.53
0.67
0.82
0.98
1.00
n/a
n/a
0.94
1.00
1.00
1.00
1.00
1.00
n/a
0.22
0.35
0.38
0.42
0.47
0.58
0.69
0.81
0.87
0.93
1.00
n/a
n/a
n/a
n/a
n/a
n/a
0.75
0.79
0.84
0.86
0.88
0.92
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.90
0.94
1.00
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 223
Spacing factor
in tension
AN
Effective
embed. hef
3-1/8
(79)
4
(102)
3-1/8
(79)
3-9/16
(90)
4-7/16
(113)
n/a
0.65
0.66
0.67
0.69
0.71
0.74
0.77
0.79
0.82
0.87
0.93
1.00
0.60
0.61
0.63
0.64
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.92
1.00
Nominal
embed. hnom
2-3/8
2-3/4
3
3-1/4
3-1/2
4
4-1/2
5
5-1/2
6
7
8
10
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(60)
(70)
(76)
(83)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(254)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
toward edge
RV
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
n/a
n/a
n/a
0.51
0.54
0.59
0.65
0.71
0.79
0.86
1.00
0.39
0.41
0.43
0.45
0.47
0.51
0.55
0.59
0.63
0.68
0.79
0.90
1.00
n/a
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.70
0.74
0.77
0.81
0.85
0.89
0.93
0.97
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.59
0.61
0.63
0.66
0.69
0.72
0.75
0.78
0.82
0.85
0.88
n/a
n/a
n/a
0.24
0.26
0.32
0.38
0.45
0.52
0.59
0.75
0.91
1.00
0.11
0.13
0.15
0.17
0.19
0.23
0.28
0.33
0.38
0.43
0.54
0.66
0.92
1.00
n/a
n/a
n/a
0.47
0.53
0.59
0.65
0.71
0.79
0.86
1.00
0.21
0.27
0.30
0.34
0.38
0.47
0.55
0.59
0.63
0.68
0.79
0.90
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.66
0.69
0.74
0.79
0.89
0.97
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.67
0.71
0.80
0.87
0.94
1.00
II to edge
RV
Conc. thickness
factor in shear4
HV
Table 23 - Load adjustment factors for 5/8-in. diameter stainless steel KWIK Bolt TZ in cracked concrete1,2
5/8-in. KB-TZ SS
cracked concrete
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
2-3/8
2-3/4
3
3-1/4
3-1/2
4
4-1/2
5
5-1/2
6
7
8
10
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(60)
(70)
(76)
(83)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(254)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
toward edge
RV
II to edge
RV
Conc. thickness
factor in shear4
HV
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
3-9/16
(90)
4-7/16
(113)
n/a
n/a
0.66
0.67
0.69
0.71
0.74
0.77
0.79
0.82
0.87
0.93
1.00
0.60
0.61
0.63
0.64
0.65
0.67
0.69
0.71
0.73
0.75
0.79
0.83
0.92
1.00
n/a
n/a
n/a
0.77
0.81
0.89
0.97
1.00
0.57
0.61
0.64
0.66
0.69
0.75
0.81
0.87
0.93
1.00
n/a
n/a
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.70
0.74
0.78
0.82
0.85
0.89
0.93
0.97
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.66
0.69
0.72
0.75
0.79
0.82
0.85
0.88
n/a
n/a
n/a
0.24
0.27
0.33
0.39
0.45
0.52
0.60
0.75
0.92
1.00
011
0.13
0.15
0.17
0.19
0.24
0.28
0.33
0.38
0.43
0.55
0.67
0.93
1.00
n/a
n/a
n/a
0.48
0.53
0.65
0.78
0.91
1.00
0.22
0.27
0.31
0.35
0.39
0.47
0.56
0.66
0.76
0.87
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.66
0.69
0.74
0.79
0.89
0.97
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.67
0.71
0.80
0.87
0.94
1.00
224 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in tension
AN
Effective
embed. hef
3-1/8
(79)
4
(102)
3-1/8
(79)
4-5/16
(110)
5-9/16
(141)
n/a
n/a
n/a
0.72
0.74
0.77
0.81
0.86
0.90
0.92
0.94
1.00
0.64
0.65
0.66
0.68
0.69
0.71
0.75
0.78
0.82
0.83
0.85
0.92
0.99
1.00
Nominal
embed. hnom
4
4-1/4
4-1/2
5
5-1/2
6
7
8
9
9-1/2
10
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(102)
(108)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(241)
(254)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
toward edge
RV
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
3-1/8
(79)
4
(102)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(142)
n/a
0.46
0.48
0.51
0.55
0.60
0.70
0.80
0.90
0.95
1.00
0.54
0.56
0.57
0.61
0.65
0.69
0.78
0.89
1.00
n/a
n/a
n/a
0.59
0.60
0.60
0.62
0.64
0.66
0.66
0.67
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.56
0.56
0.56
0.57
0.58
0.58
0.60
0.61
0.63
0.63
0.64
0.67
0.70
0.73
0.75
0.78
0.81
0.84
n/a
0.29
0.32
0.38
0.43
0.49
0.62
0.76
0.91
0.98
1.00
0.20
0.22
0.24
0.28
0.32
0.36
0.46
0.56
0.67
0.72
0.78
1.00
n/a
0.46
0.48
0.51
0.55
0.60
0.70
0.80
0.91
0.98
1.00
0.40
0.43
0.47
0.55
0.64
0.69
0.78
0.89
1.00
n/a
n/a
n/a
n/a
n/a
0.65
0.70
0.75
0.79
0.81
0.83
0.91
0.99
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.71
0.73
0.75
0.82
0.89
0.95
1.00
II to edge
RV
Conc. thickness
factor in shear4
HV
3/4-in. KB-TZ SS
cracked concrete
Effective
embed. hef
Nominal
embed. hnom
1
2
3
4
4
4-1/4
4-1/2
5
5-1/2
6
7
8
9
9-1/2
10
12
14
16
18
20
22
> 24
in.
(mm)
in.
(mm)
(102)
(108)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(241)
(254)
(305)
(356)
(406)
(457)
(508)
(559)
(610)
Edge distance
factor in tension
RN
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Table 25 - Load adjustment factors for 3/4-in. diameter stainless steel KWIK Bolt TZ in cracked concrete1,2
Spacing factor
in tension
AN
3.3.1
Spacing factor
in shear3
AV
toward edge
RV
II to edge
RV
Conc. thickness
factor in shear4
HV
3.3.8
3.3.9
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3-3/4
(95)
4-3/4
(121)
3.3.9
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(141)
4-5/16
(110)
5-9/16
(142)
3.3.9
n/a
n/a
n/a
0.72
0.74
0.77
0.81
0.86
0.90
0.92
0.94
1.00
0.64
0.65
0.66
0.68
0.69
0.71
0.75
0.78
0.82
0.83
0.85
0.92
0.99
1.00
n/a
0.81
0.85
0.91
0.98
1.00
1.00
1.00
1.00
1.00
0.68
0.70
0.73
0.77
0.83
0.88
0.99
1.00
n/a
n/a
n/a
0.57
0.58
0.58
0.60
0.61
0.62
0.63
0.64
0.67
0.69
0.72
0.75
0.78
0.81
0.83
0.56
0.56
0.56
0.57
0.58
0.59
0.60
0.61
0.63
0.64
0.64
0.67
0.70
0.73
0.76
0.78
0.81
0.84
n/a
0.21
0.23
0.27
0.31
0.35
0.44
0.54
0.65
0.70
0.76
1.00
0.20
0.22
0.24
0.28
0.32
0.37
0.46
0.56
0.67
0.73
0.79
1.00
n/a
0.42
0.46
0.54
0.62
0.71
0.89
1.00
1.00
1.00
0.40
0.44
0.48
0.56
0.64
0.73
0.92
1.00
n/a
n/a
n/a
n/a
n/a
0.58
0.62
0.67
0.71
0.73
0.74
0.82
0.88
0.94
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.72
0.74
0.75
0.83
0.89
0.95
1.00
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 225
Figure 4 - Installation of KWIK Bolt TZ in the soffit of concrete over metal deck floor and roof assemblies - W Deck
Figure 5 - Installation of KWIK Bolt TZ in the soffit of concrete over metal deck floor and roof assemblies - B Deck
226 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Shear - Vn
Shear - Vn
Nominal Effective Nominal
anchor embed. embed. 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi
diameter in. (mm) in. (mm)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
Tension - Nn
3/8
1/2
5/8
2-5/16
1,340
1,545
1,385
1,385
Tension - Nn
1,200
1,385
1,850
1,850
(51)
(59)
(6.0)
(6.9)
(6.2)
(6.2)
(5.3)
(6.2)
(8.2)
(8.2)
2-3/8
1,340
1,545
1,950
1,950
1,210
1,395
1,680
1,680
(51)
(60)
(6.0)
(6.9)
(8.7)
(8.7)
(5.4)
(6.2)
(7.5)
(7.5)
3-1/4
3-5/8
2,400
2,770
3,215
3,215
2,195
2,535
2,565
2,565
3.3.1
(83)
(92)
(10.7)
(12.3)
(14.3)
(14.3)
(9.8)
(11.3)
(11.4)
(11.4)
3.3.2
3-1/8
3-9/16
1,835
2,120
2,990
2,990
2,640
3,050
3,060
3,060
(79)
(90)
(8.2)
(9.4)
(13.3)
(13.3)
(11.7)
(13.6)
(13.6)
(13.6)
4-7/16
4,260
4,920
3,925
3,925
(102)
(113)
(18.9)
(21.9)
(17.5)
(17.5)
n/a
n/a
n/a
n/a
3.3.6
3.3.7
Shear - Vn
Tension - Nn
Shear - Vn
Tension - Nn
Nominal Effective Nominal
anchor embed. embed. 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi
diameter in. (mm) in. (mm)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
1/2
5/8
3.3.8
3.3.9
2-5/16
950
1,095
1,3858
1,3858
1,080
1,245
1,8508
1,8508
3.3.9
(51)
(59)
(4.2)
(4.9)
(6.2)
(6.2)
(4.8)
(5.5)
(8.2)
(8.2)
2-3/8
950
1,095
1,950
1,950
860
995
1,680
1,680
3.3.9
(51)
(60)
(4.2)
(4.9)
(8.7)
(8.7)
(3.8)
(4.4)
(7.5)
(7.5)
3-1/4
3-5/8
1,705
1,970
3,215
3,215
1,955
2,255
2,565
2,565
3.3.9
(83)
(92)
(7.6)
(8.8)
(14.3)
(14.3)
(8.7)
(10.0)
(11.4)
(11.4)
3-1/8
3-9/16
1,300
1,500
2,9908
2,9908
1,875
2,165
3,0608
3,0608
(79)
(90)
(5.8)
(6.7)
(13.3)
(13.3)
(8.3)
(9.6)
(13.6)
(13.6)
3.3.9
4-7/16
3,020
3,485
3,9258
3,9258
(102)
(113)
(13.4)
(15.5)
(17.5)
(17.5)
n/a
n/a
n/a
n/a
3.3.9
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x hef (effective embedment).
3.3.4
3.3.5
Table 27 - Hilti KWIK Bolt TZ carbon steel design strength in the soffit of cracked lightweight concrete
over metal deck1,2,3,4,5,6,7
3/8
3.3.3
3.3.9
Tabular values are lightweight concrete and no additional reduction factor is needed.
Comparison to steel values in table 4 is not required. Values in tables 26 and 27 control.
Tabular values are for static loads only. For seismic loads, multiply cracked concrete tabular values by seis = 0.75.
See section 3.1.7.4 for additional information on seismic applications.
For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions:
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 227
Figure 6 - Installation of the KWIK Bolt TZ on the top of sand-lightweight concrete over metal deck floor
and roof assemblies
Table 28 - Hilti KWIK Bolt TZ carbon steel design strength in the top of uncracked concrete
over metal deck1,2,3,4
Nominal
anchor
diameter
3/8
1/2
Tension - Nn
Shear - Vn
Effective
embed.
in. (mm)
Nominal
embed.
in. (mm)
2-5/16
1,790
2,070
2,605
3,005
(51)
(59)
(8.0)
(9.2)
(11.6)
(13.4)
2-3/8
2,415
2,790
2,605
3,005
(51)
(60)
(10.7)
(12.4)
(11.6)
(13.4)
Table 29 - Hilti KWIK Bolt TZ carbon steel design strength in the top of cracked concrete
over metal deck1,2,3,4,5
Nominal
anchor
diameter
3/8
1/2
Tension - Nn
Shear - Vn
Effective
embed.
in. (mm)
Nominal
embed.
in. (mm)
2-5/16
1,615
1,865
1,845
2,130
(51)
(59)
(7.2)
(8.3)
(8.2)
(9.5)
2-3/8
1,710
1,975
1,845
2,130
(51)
(60)
(7.6)
(8.8)
(8.2)
(9.5)
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Apply spacing, edge distance, and concrete thickness factors in tables 30 and 31 as necessary. Compare to the steel values
in table 4. The lesser of the values is to be used for the design.
Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by a as follows:
Tabular values are for static loads only. For seismic loads, multiply cracked concrete tabular values by seis = 0.75.
See section 3.1.7.4 for additional information on seismic applications.
228 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
II to edge
RV
Conc. thickness
factor in shear4
HV
Anchor
diameter da
in.
(mm)
in.
(mm)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
Nominal
embed. hnom
in.
(mm)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
(76)
(83)
(89)
(102)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)
(254)
(279)
(305)
n/a
n/a
n/a
0.83
0.88
0.92
0.96
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
1.00
0.33
0.36
0.39
0.44
0.50
0.56
0.61
0.67
0.72
0.78
0.89
1.00
n/a
n/a
n/a
n/a
0.50
0.56
0.61
0.67
0.72
0.78
0.89
1.00
n/a
n/a
n/a
0.67
0.69
0.71
0.73
0.75
0.77
0.79
0.83
0.87
0.91
0.95
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.78
0.81
0.85
0.89
0.94
0.98
1.00
0.64
0.72
0.81
0.99
1.00
n/a
n/a
n/a
n/a
1.00
0.64
0.72
0.81
0.99
1.00
n/a
n/a
n/a
n/a
1.00
n/a
0.73
0.76
0.81
n/a
0.75
0.78
0.84
Effective
embed. hef
3
3-1/4
3-1/2
4
4-1/2
5
5-1/2
6
6-1/2
7
8
9
10
11
12
3.3.4
3.3.5
3.3.6
3.3.7
Table 31 - Load adjustment factors for carbon steel KWIK Bolt TZ in the top of cracked concrete over metal deck
Spacing factor
in shear3
AV
toward edge
RV
II to edge
RV
3.3.8
Conc. thickness
factor in shear4
HV
in.
(mm)
in.
(mm)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
3/8
(9.5)
2
(51)
1/2
(12.7)
2
(51)
Nominal
embed. hnom
in.
(mm)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
2-5/16
(59)
2-3/8
(60)
(76)
(83)
(89)
(102)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)
(254)
(279)
(305)
n/a
n/a
n/a
0.83
0.88
0.92
0.96
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
1.00
1.00
n/a
n/a
n/a
n/a
1.00
n/a
n/a
n/a
0.67
0.69
0.71
0.73
0.75
0.77
0.79
0.83
0.87
0.92
0.96
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.79
0.81
0.85
0.90
0.94
0.98
1.00
0.65
0.73
0.82
1.00
n/a
n/a
n/a
n/a
1.00
1.00
n/a
n/a
n/a
n/a
1.00
n/a
0.74
0.76
0.82
n/a
0.76
0.79
0.84
Edge distance
factor in tension
RN
Anchor
diameter da
Effective
embed. hef
1
2
Spacing factor
in tension
AN
3
3-1/4
3-1/2
4
4-1/2
5
5-1/2
6
6-1/2
7
8
9
10
11
12
3.3.2
3.3.3
1,2
3.3.1
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 229
Length
Threaded length
Box quantity
7/8
50
3-3/4
1-5/8
50
2-7/8
50
3-3/4
1-5/8
20
4-1/2
2-3/8
20
KB-TZ 1/2x5-1/2
5-1/2
3-3/8
20
KB-TZ 1/2x7
4-7/8
20
KB-TZ 5/8x4-3/4
4-3/4
1-1/2
15
KB-TZ 5/8x6
2-3/4
15
KB-TZ 5/8x8-1/2
8-1/2
5-1/4
15
KB-TZ 5/8x10
10
6-3/4
15
KB-TZ 3/4x5-1/2
5 1/2
1-1/2
10
KB-TZ 3/4x8
10
KB-TZ 3/4x10
10
10
KB-TZ 3/8x3
KB-TZ 3/8x3-3/4
KB-TZ 3/8x5
KB-TZ 1/2x3-3/4
KB-TZ 1/2x4-1/2
From
Up to
but not
including
1 12
2 1 2
3 12
4 12
5 12
6 12
7 12
8 12
9 12
10
11
12
13
14
15
2 12
3 12
4 12
5 12
6 12
7 12
8 12
9 12
10
11
12
13
14
15
16
Figure 7 Bolt head with length identification mark and KWIK Bolt TZ head notch embossment
230 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Product features
3.3.6.1
Product description
3.3.6.2
Material specifications
3.3.1
3.3.3
3.3.2
3.3.4
3.3.5
3.3.7
3.3.6
3.3.6.2 Material
specifications
3.3.8
3.3.7
3.3.6.3 Technical
data
The technical data contained in this
section are Hilti Simplified Design
Tables. The load values were
developed using the Strength Design
parameters and variables of ESR-3027
and the equations within ACI 318
Appendix D. For a detailed explanation
of the Hilti Simplified Design Method,
refer to section 3.1.7. Data tables from
ESR-3027 are not contained in this
section, but can be found on www.icces.org or at www.us.hilti.com.
3.3.9
3.3.7
Listings/Approvals
ICC-ES (International Code Council)
ESR-3027
Cracked and Uncracked Concrete
ESR-3056
Grout-filled concrete masonry
City of Los Angeles
Research Report No. 25897
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 231
Units
1/4
3/8
1/2
5/8
3/4
1/4
3/8
1/2
5/8
3/4
dbit
Minimum nominal
embedment
hnom
in.
1-5/8
2-1/2
1-5/8
2-1/2
3-1/4
2-1/4
4-1/4
3-1/4
6-1/4
Minimum effective
embedment
hef
in.
1.18
1.92
1.11
1.86
2.50
1.50
2.16
3.22
2.39
3.88
2.92
4.84
ho
in.
2-7/8
1-7/8
2-3/4
3-1/2
2-5/8
3-3/8
4-5/8
3-5/8
5-3/8
4-4/8
6-5/8
dh
in.
3/8
ft-lb
18
Installation torque
Maximum impact wrench
torque rating2
Wrench size
Tinst
Timpact,max
1/2
5/8
3/4
7/8
85
115
(115)
(155)
19
45
(26)
(54)
ft-lb
114
137
114
450
137
450
450
450
(Nm)
(154)
(185)
(154)
(608)
(185)
(608)
(608)
(608)
15/16
1-1/8
in.
(24)
40
7/16
9/16
(61)
3/4
1 Tinst is the maximum installation torque that may be applied with a torque wrench.
2 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over
torquing can damage the anchor and/or reduce its holding capacity.
232 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
1/4
3/8
1/2
5/8
3/4
Shear - Vn
Tension - Nn
Nominal
embed.
in. (mm)
1-5/8
(41)
585
(2.6)
620
(2.8)
675
(3.0)
765
(3.4)
1,075
(4.8)
1,180
(5.2)
1,360
(6.0)
1,670
(7.4)
2-1/2
1,525
1,670
1,930
2,365
2,235
2,450
2,825
3,460
(64)
1-5/8
(41)
2-1/2
(64)
3-1/4
(83)
2-1/4
(57)
3
(76)
4-1/4
(108)
3-1/4
(83)
5
(127)
4
(102)
6-1/4
(159)
(6.8)
910
(4.0)
1,980
(8.8)
3,085
(13.7)
1,645
(7.3)
2,785
(12.4)
5,070
(22.6)
3,240
(14.4)
6,705
(29.8)
4,380
(19.5)
9,345
(41.6)
(7.4)
1,000
(4.4)
2,165
(9.6)
3,375
(15.0)
1,800
(8.0)
3,050
(13.6)
5,555
(24.7)
3,550
(15.8)
7,345
(32.7)
4,795
(21.3)
10,235
(45.5)
(8.6)
1,155
(5.1)
2,505
(11.1)
3,900
(17.3)
2,080
(9.3)
3,525
(15.7)
6,415
(28.5)
4,100
(18.2)
8,485
(37.7)
5,540
(24.6)
11,820
(52.6)
(10.5)
1,415
(6.3)
3,065
(13.6)
4,775
(21.2)
2,550
(11.3)
4,315
(19.2)
7,855
(34.9)
5,025
(22.4)
10,390
(46.2)
6,785
(30.2)
14,475
(64.4)
(9.9)
980
(4.4)
2,130
(9.5)
6,640
(29.5)
1,770
(7.9)
3,000
(13.3)
10,920
(48.6)
3,490
(15.5)
14,445
(64.3)
9,430
(41.9)
20,125
(89.5)
(10.9)
1,075
(4.8)
2,335
(10.4)
7,275
(32.4)
1,940
(8.6)
3,285
(14.6)
11,965
(53.2)
3,825
(17.0)
15,825
(70.4)
10,330
(45.9)
22,045
(98.1)
(12.6)
1,245
(5.5)
2,695
(12.0)
8,400
(37.4)
2,240
(10.0)
3,795
(16.9)
13,815
(61.5)
4,415
(19.6)
18,270
(81.3)
11,930
(53.1)
25,455
(113.2)
(15.4)
1,520
(6.8)
3,300
(14.7)
10,290
(45.8)
2,745
(12.2)
4,645
(20.7)
16,920
(75.3)
5,410
(24.1)
22,380
(99.6)
14,610
(65.0)
31,175
(138.7)
Table 3 - Hilti KWIK HUS-EZ design strength with concrete / pullout failure in cracked concrete1,2,3,4,5
Nominal
anchor
diameter
1/4
3/8
1/2
5/8
3/4
1
2
3
4
5
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Shear - Vn
Tension - Nn
3.3.1
Nominal
embed.
in. (mm)
3.3.7
1-5/8
(41)
300
(1.3)
315
(1.4)
345
(1.5)
390
(1.7)
765
(3.4)
835
(3.7)
965
(4.3)
1,180
(5.2)
3.3.7
2-1/2
760
830
960
1,175
1,585
1,735
2,000
2,450
(64)
1-5/8
(41)
2-1/2
(64)
3-1/4
(83)
2-1/4
(57)
3
(76)
4-1/4
(108)
3-1/4
(83)
5
(127)
4
(102)
6-1/4
(159)
(3.4)
475
(2.1)
1,400
(6.2)
2,185
(9.7)
1,035
(4.6)
1,755
(7.8)
3,190
(14.2)
2,040
(9.1)
4,225
(18.8)
2,755
(12.3)
5,885
(26.2)
(3.7)
520
(2.3)
1,535
(6.8)
2,390
(10.6)
1,135
(5.0)
1,920
(8.5)
3,495
(15.5)
2,235
(9.9)
4,625
(20.6)
3,020
(13.4)
6,445
(28.7)
(4.3)
600
(2.7)
1,775
(7.9)
2,765
(12.3)
1,310
(5.8)
2,220
(9.9)
4,040
(18.0)
2,580
(11.5)
5,340
(23.8)
3,485
(15.5)
7,440
(33.1)
(5.2)
730
(3.2)
2,170
(9.7)
3,385
(15.1)
1,605
(7.1)
2,715
(12.1)
4,945
(22.0)
3,165
(14.1)
6,540
(29.1)
4,270
(19.0)
9,115
(40.5)
(7.1)
695
(3.1)
1,510
(6.7)
4,705
(20.9)
1,115
(5.0)
1,890
(8.4)
6,875
(30.6)
2,200
(9.8)
9,095
(40.5)
5,940
(26.4)
12,670
(56.4)
(7.7)
760
(3.4)
1,655
(7.4)
5,155
(22.9)
1,220
(5.4)
2,070
(9.2)
7,530
(33.5)
2,410
(10.7)
9,965
(44.3)
6,505
(28.9)
13,880
(61.7)
(8.9)
880
(3.9)
1,910
(8.5)
5,950
(26.5)
1,410
(6.3)
2,390
(10.6)
8,695
(38.7)
2,780
(12.4)
11,505
(51.2)
7,510
(33.4)
16,030
(71.3)
(10.9)
1,080
(4.8)
2,340
(10.4)
7,285
(32.4)
1,725
(7.7)
2,925
(13.0)
10,650
(47.4)
3,405
(15.1)
14,090
(62.7)
9,200
(40.9)
19,630
(87.3)
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 233
Nominal embedment
in. (mm)
1-5/8
(41)
1/4
1-5/8
(41)
3/8
2-1/2
(64)
2-1/4
(57)
3-1/4
(83)
4
(102)
1/2
5/8
3/4
3
(76)
3-1/4
(83)
4-1/4
(108)
5
(127)
6-1/4
(159)
Shear4 Vsa
lb (kN)
3,945
(17.5)
5,980
(26.6)
6,720
(29.9)
11,780
(52.4)
15,735
(70.0)
20,810
(92.6)
930
(4.1)
2,200
(9.8)
3,110
(13.8)
5,545
(24.7)
6,735
(30.0)
9,995
(44.5)
835
(3.7)
2,200
(9.8)
1,865
(8.3)
3,330
(14.8)
4,040
(18.0)
6,935
(30.8)
Figure 2
cmin,2
Case 2
(smin,1 smin,2)
s smin,2 + ___________ (c cmin,2)
(cmin,1 cmin,2)
cmin,1
Case 1
smin,2
smin,1
spacing s
1
2
3
4
5
2-1/2
(64)
Tensile3 Nsa
lb (kN)
cmin,1 at smin,1
sdesign
cmin,2 at smin,2
cdesign
Concrete
Edge
edge distance c
Symbol
Units
hef
in.
1.18
hmin
in.
c min,1
in.
for s min,1
in.
c min,2
in.
for s min,2
in.
1/4
1.92
2.78
1.11
2.63
1.50
3/8
1.86
2.50
1.50
2.16
3.22
2.92
3.75
2.75
3.75
2.25
5.25
5/8
2.39
3/4
3.88
2.92
4.84
8-1/8
3.63
5.81
4.41
7.28
1.50
1.75
3
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge .distance c, where cmin,1 < c < cmin,2 will determine the permissible spacings.
234 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Embedment hnom
1-1/2
2
2-1/2
3
3-1/4
3-1/2
4
4-1/8
4-1/2
5
5-1/2
6
7
8
9
10
11
12
14
in.
(mm)
(38)
(51)
(64)
(76)
(83)
(89)
(102)
(105)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
Spacing factor
in tension
AN
1-5/8
(41)
0.71
0.78
0.85
0.92
0.96
0.99
1.00
2-1/2
(64)
0.63
0.67
0.72
0.76
0.78
0.80
0.85
0.86
0.89
0.93
0.98
1.00
Edge distance
factor in tension
RN
1-5/8
(41)
0.78
1.00
2-1/2
(64)
0.65
0.77
0.90
1.00
Spacing factor
in shear3
AV
1-5/8
(41)
0.59
0.62
0.65
0.68
0.70
0.71
0.74
0.75
0.77
0.80
0.83
0.86
0.92
0.98
1.00
2-1/2
(64)
0.56
0.58
0.60
0.62
0.63
0.64
0.66
0.66
0.68
0.70
0.72
0.74
0.78
0.82
0.86
0.89
0.93
0.97
1.00
2-1/2
(64)
0.21
0.33
0.46
0.60
0.68
0.76
0.92
0.97
1.00
II to edge
RV
1-5/8
(41)
0.78
1.00
2-1/2
(64)
0.42
0.65
0.90
1.00
Conc. thickness
factor in shear4
HV
1-5/8
(41)
n/a
n/a
n/a
n/a
0.88
0.92
0.98
1.00
2-1/2
(64)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.81
0.84
0.89
0.93
0.97
1.00
1/4-in. KH-EZ
cracked concrete
Embedment hnom
1
2
3
4
1-1/2
2
2-1/2
3
3-1/4
3-1/2
4
4-1/8
4-1/2
5
5-1/2
6
7
8
9
10
11
12
14
in.
(mm)
(38)
(51)
(64)
(76)
(83)
(89)
(102)
(105)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
1-5/8
(41)
0.71
0.78
0.85
0.92
0.96
0.99
1.00
2-1/2
(64)
0.63
0.67
0.72
0.76
0.78
0.80
0.85
0.86
0.89
0.93
0.98
1.00
Edge distance
factor in tension
RN
1-5/8
(41)
0.88
1.00
2-1/2
(64)
0.65
0.77
0.90
1.00
Spacing factor
in shear3
AV
1-5/8
(41)
0.59
0.62
0.65
0.68
0.70
0.71
0.74
0.75
0.77
0.80
0.83
0.86
0.92
0.98
1.00
2-1/2
(64)
0.56
0.58
0.60
0.62
0.63
0.64
0.66
0.66
0.68
0.70
0.72
0.74
0.78
0.82
0.86
0.90
0.94
0.98
1.00
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Table 7 - Load adjustment factors for 1/4-in. diameter KWIK HUS-EZ in cracked concrete1,2
Spacing factor
in tension
AN
3.3.1
3.3.8
2-1/2
(64)
0.21
0.33
0.46
0.60
0.68
0.76
0.93
0.97
1.00
II to edge
RV
1-5/8
(41)
0.80
1.00
2-1/2
(64)
0.43
0.66
0.90
1.00
Conc. thickness
factor in shear4
HV
1-5/8
(41)
n/a
n/a
n/a
n/a
0.89
0.92
0.98
1.00
2-1/2
(64)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.81
0.85
0.89
0.93
0.98
1.00
3.3.9
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 235
3/8-in. KH-EZ
uncracked concrete
in.
Embedment hnom
(mm)
1-1/2
(38)
2
(51)
2-1/4
(57)
2-1/2
(64)
3
(76)
3-1/4
(83)
3-1/2
(89)
4
(102)
4-1/2
(114)
4-3/4
(121)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
(41)
n/a
n/a
0.84
0.88
0.95
0.99
1.00
(64)
n/a
n/a
0.70
0.72
0.77
0.79
0.81
0.86
0.90
0.93
0.95
1.00
(83)
n/a
n/a
0.65
0.67
0.70
0.72
0.73
0.77
0.80
0.82
0.83
0.90
0.97
1.00
(41)
0.58
0.76
0.86
0.95
1.00
(64)
0.63
0.75
0.81
0.88
1.00
(83)
0.57
0.66
0.70
0.75
0.85
0.90
0.95
1.00
(41)
n/a
n/a
0.65
0.67
0.71
0.72
0.74
0.78
0.81
0.83
0.84
0.91
0.98
1.00
(64)
n/a
n/a
0.60
0.61
0.63
0.64
0.65
0.68
0.70
0.71
0.72
0.76
0.81
0.85
0.90
0.94
0.98
1.00
(83)
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.63
0.65
0.67
0.69
0.71
0.74
0.76
0.80
0.84
0.89
0.93
1.00
(41)
0.49
0.75
0.90
1.00
1.00
(64)
0.25
0.38
0.46
0.54
0.71
0.80
0.89
1.00
(83)
0.08
0.13
0.16
0.18
0.24
0.27
0.30
0.37
0.44
0.48
0.52
0.68
0.86
1.00
(41)
0.58
0.76
0.90
1.00
1.00
(64)
0.50
0.75
0.81
0.88
1.00
(83)
0.17
0.26
0.31
0.37
0.48
0.54
0.61
0.74
0.88
0.96
1.00
(41)
n/a
n/a
n/a
n/a
n/a
0.95
0.98
1.00
(64)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.84
0.89
0.91
0.94
1.00
(83)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.64
0.66
0.72
0.78
0.83
0.88
0.93
0.97
1.00
Table 9 - Load adjustment factors for 3/8-in. diameter KWIK HUS-EZ in cracked concrete1,2
3/8-in. KH-EZ
Cracked concrete
in.
Embedment hnom
(mm)
1-1/2
(38)
2
(51)
2-1/4
(57)
2-1/2
(64)
3
(76)
3-1/4
(83)
3-1/2
(89)
4
(102)
4-1/2
(114)
4-3/4
(121)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
1
2
3
4
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
1-5/8
2-1/2
3-1/4
(41)
n/a
n/a
0.84
0.88
0.95
0.99
1.00
(64)
n/a
n/a
0.70
0.72
0.77
0.79
0.81
0.86
0.90
0.93
0.95
1.00
(83)
n/a
n/a
0.65
0.67
0.70
0.72
0.73
0.77
0.80
0.82
0.83
0.90
0.97
1.00
(41)
0.92
1.00
1.00
1.00
1.00
(64)
0.66
0.79
0.85
0.92
1.00
(83)
0.57
0.66
0.70
0.75
0.85
0.90
0.95
1.00
(41)
n/a
n/a
0.66
0.67
0.71
0.73
0.74
0.78
0.81
0.83
0.85
0.92
0.98
1.00
(64)
n/a
n/a
0.60
0.61
0.63
0.64
0.65
0.68
0.70
0.71
0.72
0.77
0.81
0.85
0.90
0.94
0.99
1.00
(83)
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.59
0.60
0.60
0.61
0.63
0.65
0.67
0.69
0.72
0.74
0.76
0.80
0.85
0.89
0.93
1.00
(41)
0.49
0.76
0.90
1.00
1.00
(64)
0.25
0.39
0.46
0.54
0.71
0.80
0.90
1.00
(83)
0.09
0.13
0.16
0.18
0.24
0.27
0.31
0.37
0.44
0.48
0.52
0.69
0.86
1.00
(41)
0.92
1.00
1.00
1.00
1.00
(64)
0.50
0.77
0.85
0.92
1.00
(83)
0.17
0.26
0.31
0.37
0.48
0.55
0.61
0.75
0.89
0.97
1.00
(41)
n/a
n/a
n/a
n/a
n/a
0.95
0.98
1.00
(64)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.84
0.89
0.92
0.94
1.00
(83)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.64
0.66
0.72
0.78
0.83
0.88
0.93
0.97
1.00
236 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
1/2-in. KH-EZ
uncracked concrete
in.
Embedment hnom
(mm)
1-3/4
(44)
2
(51)
2-1/2
(64)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
4-3/4
(121)
5
(127)
6
(152)
6-3/4
(171)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
> 24
(610)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
(57)
n/a
n/a
n/a
0.83
0.88
0.94
0.99
1.00
(76)
n/a
n/a
n/a
0.73
0.77
0.81
0.85
0.87
0.89
0.96
1.00
(108)
n/a
n/a
n/a
0.66
0.68
0.71
0.73
0.75
0.76
0.81
0.85
0.86
0.91
0.97
1.00
(57)
0.68
0.75
0.91
1.00
(76)
0.57
0.62
0.71
0.81
0.93
1.00
(108)
0.51
0.54
0.60
0.66
0.73
0.80
0.87
0.91
0.95
1.00
(57)
n/a
n/a
n/a
0.65
0.68
0.71
0.73
0.74
0.76
0.81
0.85
0.86
0.91
0.96
1.00
(76)
n/a
n/a
n/a
0.61
0.63
0.65
0.67
0.68
0.69
0.73
0.76
0.77
0.80
0.84
0.88
0.92
0.95
1.00
(108)
n/a
n/a
n/a
0.55
0.56
0.57
0.58
0.58
0.58
0.60
0.61
0.62
0.64
0.65
0.67
0.69
0.70
0.74
0.77
0.80
0.84
0.91
(57)
0.40
0.48
0.68
0.89
1.00
(76)
0.25
0.31
0.43
0.56
0.71
0.87
1.00
(108)
0.07
0.09
0.13
0.17
0.21
0.26
0.31
0.33
0.36
0.47
0.57
0.60
0.73
0.87
1.00
(57)
0.68
0.75
0.91
1.00
(76)
0.50
0.61
0.71
0.81
0.93
1.00
(108)
0.15
0.18
0.25
0.33
0.42
0.52
0.62
0.67
0.72
0.95
1.00
(57)
n/a
n/a
n/a
n/a
n/a
n/a
0.96
0.99
1.00
(76)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.85
0.87
0.95
1.00
(108)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.68
0.69
0.73
0.78
0.82
0.86
0.90
0.97
1.00
1/2-in. KH-EZ
cracked concrete
in.
Embedment hnom
(mm)
1-3/4
(44)
2
(51)
2-1/2
(64)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
4-3/4
(121)
5
(127)
6
(152)
6-3/4
(171)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
> 24
(610)
1
2
3
4
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Table 11 - Load adjustment factors for 1/2-in. diameter KWIK HUS-EZ in cracked concrete1,2
Spacing factor
in tension
AN
3.3.1
II to edge
RV
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
2-1/4
4-1/4
(57)
n/a
n/a
n/a
0.83
0.88
0.94
0.99
1.00
(76)
n/a
n/a
n/a
0.73
0.77
0.81
0.85
0.87
0.89
0.96
1.00
(108)
n/a
n/a
n/a
0.66
0.68
0.71
0.73
0.75
0.76
0.81
0.85
0.86
0.91
0.97
1.00
(57)
0.82
0.90
1.00
1.00
(76)
0.66
0.72
0.83
0.94
1.00
1.00
(108)
0.55
0.58
0.65
0.72
0.79
0.87
0.95
0.99
1.00
1.00
(57)
n/a
n/a
n/a
0.67
0.70
0.72
0.75
0.77
0.78
0.84
0.88
0.89
0.95
1.00
(76)
n/a
n/a
n/a
0.62
0.64
0.66
0.69
0.70
0.71
0.75
0.78
0.79
0.83
0.87
0.91
0.95
0.99
1.00
(108)
n/a
n/a
n/a
0.56
0.56
0.57
0.58
0.59
0.59
0.61
0.62
0.63
0.65
0.67
0.68
0.70
0.72
0.76
0.79
0.83
0.87
0.94
(57)
0.45
0.55
0.77
1.00
(76)
0.28
0.35
0.49
0.64
0.80
0.98
1.00
(108)
0.08
0.10
0.14
0.19
0.24
0.29
0.35
0.38
0.41
0.54
0.64
0.68
0.83
0.99
1.00
(57)
0.82
0.90
1.00
1.00
(76)
0.57
0.70
0.83
0.94
1.00
1.00
(108)
0.17
0.21
0.29
0.38
0.48
0.59
0.70
0.76
0.82
1.00
(57)
n/a
n/a
n/a
n/a
n/a
n/a
1.00
(76)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.88
0.91
0.99
1.00
(108)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.70
0.72
0.77
0.81
0.86
0.90
0.94
1.00
3.3.8
3.3.9
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 237
Embedment hnom
1-3/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
14
16
18
20
24
> 30
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
in.
(mm)
3-1/4
(83)
5
(127)
3-1/4
(83)
5
(127)
3-1/4
(83)
5
(127)
(44)
(51)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
n/a
n/a
n/a
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.99
1.00
n/a
n/a
n/a
0.63
0.65
0.67
0.69
0.71
0.74
0.76
0.80
0.84
0.89
0.93
0.97
1.00
0.62
0.67
0.76
0.86
0.97
1.00
0.51
0.54
0.59
0.65
0.70
0.76
0.83
0.89
0.96
1.00
n/a
n/a
n/a
0.61
0.63
0.65
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
0.90
0.94
1.00
n/a
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.61
0.62
0.64
0.65
0.67
0.68
0.71
0.74
0.77
0.80
0.86
0.95
II to edge
RV
3-1/4
(83)
5
(127)
3-1/4
(83)
5
(127)
0.24
0.29
0.40
0.53
0.66
0.81
0.97
1.00
0.06
0.08
0.11
0.14
0.18
0.22
0.26
0.30
0.35
0.40
0.50
0.61
0.73
0.86
0.99
1.00
0.47
0.57
0.76
0.86
0.97
1.00
0.13
0.15
0.21
0.28
0.35
0.43
0.52
0.60
0.70
0.80
1.00
Conc. thickness
factor in shear4
HV
3-1/4
(83)
5
(127)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.85
0.89
0.93
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.69
0.74
0.78
0.81
0.85
0.92
0.98
1.00
Table 13 - Load adjustment factors for 5/8-in. diameter KWIK HUS-EZ in cracked concrete1,2
5/8-in. KH-EZ
cracked concrete
Embedment hnom
1
2
3
4
1-3/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
14
16
18
20
24
> 30
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
in.
(mm)
3-1/4
(83)
5
(127)
3-1/4
(83)
5
(127)
3-1/4
(83)
5
(127)
(44)
(51)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
n/a
n/a
n/a
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.99
1.00
n/a
n/a
n/a
0.63
0.65
0.67
0.69
0.71
0.74
0.76
0.80
0.84
0.89
0.93
0.97
1.00
0.63
0.68
0.77
0.87
0.98
1.00
0.51
0.54
0.59
0.65
0.70
0.76
0.83
0.89
0.96
1.00
n/a
n/a
n/a
0.62
0.64
0.66
0.68
0.70
0.72
0.74
0.78
0.82
0.86
0.89
0.93
0.97
1.00
n/a
n/a
n/a
0.55
0.56
0.57
0.57
0.58
0.59
0.60
0.61
0.63
0.65
0.66
0.68
0.70
0.73
0.76
0.79
0.83
0.89
0.99
II to edge
RV
3-1/4
(83)
5
(127)
3-1/4
(83)
5
(127)
0.27
0.33
0.46
0.60
0.75
0.92
1.00
0.07
0.09
0.12
0.16
0.20
0.25
0.29
0.34
0.40
0.45
0.57
0.69
0.83
0.97
1.00
0.53
0.65
0.77
0.87
0.98
1.00
0.14
0.17
0.24
0.32
0.40
0.49
0.59
0.69
0.79
0.90
1.00
Conc. thickness
factor in shear4
HV
3-1/4
(83)
5
(127)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.89
0.93
0.97
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.68
0.72
0.77
0.81
0.85
0.89
0.96
1.00
238 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Embedment hnom
1-3/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
8-1/8
9
10
11
12
14
16
18
20
24
30
> 36
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
in.
(mm)
4
(102)
6-1/4
(159)
4
(102)
6-1/4
(159)
4
(102)
6-1/4
(159)
(44)
(51)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(206)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
n/a
n/a
n/a
0.67
0.70
0.73
0.76
0.79
0.81
0.84
0.90
0.96
0.96
1.00
n/a
n/a
n/a
0.60
0.62
0.64
0.65
0.67
0.69
0.71
0.74
0.78
0.78
0.81
0.84
0.88
0.91
0.98
1.00
0.57
0.61
0.68
0.76
0.84
0.93
1.00
0.48
0.50
0.54
0.58
0.62
0.67
0.72
0.76
0.81
0.86
0.97
1.00
n/a
n/a
n/a
0.56
0.57
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.66
0.68
0.70
0.72
0.74
0.78
0.82
0.86
0.90
0.98
1.00
n/a
n/a
n/a
0.54
0.55
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.62
0.63
0.64
0.65
0.68
0.71
0.73
0.76
0.81
0.89
0.96
II to edge
RV
4
(102)
6-1/4
(159)
4
(102)
6-1/4
(159)
0.10
0.12
0.16
0.21
0.27
0.33
0.39
0.46
0.53
0.61
0.77
0.94
0.96
1.00
0.05
0.06
0.08
0.11
0.14
0.17
0.20
0.24
0.28
0.31
0.40
0.48
0.50
0.58
0.68
0.78
0.89
1.00
0.19
0.23
0.33
0.43
0.54
0.66
0.79
0.92
1.00
0.10
0.12
0.17
0.22
0.28
0.34
0.41
0.48
0.55
0.63
0.79
0.97
0.99
1.00
Conc. thickness
factor in shear4
HV
4
(102)
6-1/4
(159)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.69
0.75
0.80
0.80
0.85
0.89
0.94
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.68
0.72
0.75
0.79
0.85
0.91
0.96
1.00
Embedment hnom
1
2
3
4
1-3/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
8-1/8
9
10
11
12
14
16
18
20
24
30
> 36
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
in.
(mm)
4
(102)
6-1/4
(159)
4
(102)
6-1/4
(159)
4
(102)
6-1/4
(159)
(44)
(51)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(206)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
n/a
n/a
n/a
0.67
0.70
0.73
0.76
0.79
0.81
0.84
0.90
0.96
0.96
1.00
n/a
n/a
n/a
0.60
0.62
0.64
0.65
0.67
0.69
0.71
0.74
0.78
0.78
0.81
0.84
0.88
0.91
0.98
1.00
0.57
0.61
0.68
0.76
0.85
0.93
1.00
0.48
0.50
0.54
0.58
0.63
0.67
0.72
0.77
0.81
0.87
0.97
1.00
n/a
n/a
n/a
0.57
0.58
0.59
0.60
0.61
0.62
0.63
0.65
0.67
0.68
0.70
0.72
0.74
0.76
0.80
0.85
0.89
0.93
1.00
n/a
n/a
n/a
0.54
0.55
0.56
0.56
0.57
0.58
0.58
0.60
0.61
0.61
0.63
0.64
0.65
0.67
0.70
0.72
0.75
0.78
0.84
0.92
1.00
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Table 15 - Load adjustment factors for 3/4-in. diameter KWIK HUS-EZ in cracked concrete1,2
3/4-in. KH-EZ
cracked concrete
3.3.1
II to edge
RV
4
(102)
6-1/4
(159)
4
(102)
6-1/4
(159)
0.11
0.13
0.19
0.24
0.31
0.38
0.45
0.52
0.60
0.69
0.87
1.00
0.06
0.07
0.10
0.13
0.16
0.19
0.23
0.27
0.31
0.36
0.45
0.55
0.56
0.66
0.77
0.89
1.00
0.22
0.27
0.37
0.49
0.61
0.75
0.90
1.00
0.11
0.14
0.19
0.25
0.32
0.39
0.46
0.54
0.63
0.71
0.90
1.00
Conc. thickness
factor in shear4
HV
4
(102)
6-1/4
(159)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.72
0.78
0.83
0.84
0.88
0.93
0.98
1.00
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.67
0.71
0.75
0.78
0.82
0.89
0.95
1.00
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 239
3/8
1/2
5/8
3/4
Tension - Nn
Shear - Vn
Tension - Nn
Shear - Vn
Nominal
embedment
in. (mm)
1-5/8
(41)
2-1/2
(64)
1-5/8
(41)
2-1/2
(64)
3-1/4
(83)
2-1/4
(57)
3
(76)
4-1/4
(108)
3-1/4
(83)
5
(127)
4
(102)
545
(2.4)
1,220
(5.4)
845
(3.8)
1,455
(6.5)
2,550
(11.3)
850
(3.8)
1,990
(8.9)
3,485
(15.5)
2,715
(12.1)
6,170
(27.4)
2,715
(12.1)
595
(2.6)
1,410
(6.3)
975
(4.3)
1,680
(7.5)
2,945
(13.1)
980
(4.4)
2,300
(10.2)
4,025
(17.9)
3,135
(13.9)
7,125
(31.7)
3,135
(13.9)
725
(3.2)
1,325
(5.9)
905
(4.0)
905
(4.0)
2,165
(9.6)
965
(4.3)
1,750
(7.8)
2,155
(9.6)
2,080
(9.3)
2,515
(11.2)
2,255
(10.0)
725
(3.2)
1,325
(5.9)
905
(4.0)
905
(4.0)
2,165
(9.6)
965
(4.3)
1,750
(7.8)
2,155
(9.6)
2,080
(9.3)
2,515
(11.2)
2,255
(10.0)
670
(3.0)
1,275
(5.7)
970
(4.3)
1,900
(8.5)
730
(3.2)
1,470
(6.5)
1,120
(5.0)
2,195
(9.8)
725
(3.2)
1,960
(8.7)
2,200
(9.8)
3,655
(16.3)
725
(3.2)
1,960
(8.7)
2,200
(9.8)
3,655
(16.3)
n/a
n/a
n/a
n/a
905
(4.0)
1,045
(4.6)
4,710
(21.0)
4,710
(21.0)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Table 17 - Hilti KWIK HUS-EZ in the soffit of cracked lightweight concrete over metal deck1,2,3,4,5,6
Installation in lower flute
Nominal
anchor
diameter
1/4
3/8
1/2
5/8
3/4
1
2
3
4
5
6
7
8
Tension - Nn7
Shear - Vn7,8
Tension - Nn7
Shear - Vn7,8
Nominal
embedment
in. (mm)
1-5/8
(41)
2-1/2
(64)
1-5/8
(41)
2-1/2
(64)
3-1/4
(83)
2-1/4
(57)
3
(76)
4-1/4
(108)
3-1/4
(83)
5
(127)
4
(102)
280
(1.2)
605
(2.7)
525
(2.3)
1,035
(4.6)
1,805
(8.0)
535
(2.4)
1,255
(5.6)
2,195
(9.8)
1,710
(7.6)
3,885
(17.3)
1,710
(7.6)
305
(1.4)
700
(3.1)
605
(2.7)
1,195
(5.3)
2,085
(9.3)
620
(2.8)
1,450
(6.4)
2,535
(11.3)
1,975
(8.8)
4,485
(20.0)
1,975
(8.8)
725
(3.2)
1,325
(5.9)
905
(4.0)
905
(4.0)
2,165
(9.6)
965
(4.3)
1,750
(7.8)
2,155
(9.6)
2,080
(9.3)
2,515
(11.2)
2,255
(10.0)
725
(3.2)
1,325
(5.9)
905
(4.0)
905
(4.0)
2,165
(9.6)
965
(4.3)
1,750
(7.8)
2,155
(9.6)
2,080
(9.3)
2,515
(11.2)
2,255
(10.0)
340
(1.5)
635
(2.8)
770
(3.4)
1,345
(6.0)
370
(1.6)
735
(3.3)
890
(4.0)
1,555
(6.9)
725
(3.2)
1,960
(8.7)
2,200
(9.8)
3,655
(16.3)
725
(3.2)
1,960
(8.7)
2,200
(9.8)
3,655
(16.3)
n/a
n/a
n/a
n/a
640
(2.8)
740
(3.3)
4,710
(21.0)
4,710
(21.0)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
240 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1
3.3.2
3.3.3
3.3.4
1 A
nchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is
satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset
distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge
distance is also satisfied.
Figure 4 Installation of KWIK HUS-EZ on the top of sand-lightweight concrete over metal floor and roof assemblies
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 241
Nominal
embed.
depth
in. (mm)
Shear - Vn
Tension - Nn
'c = 3000 psi
(20.7 MPa)
lb (kN)
1/4
1-5/8
620
675
1,180
1,360
(6.4)
(41)
(2.8)
(3.0)
(5.2)
(6.0)
3/8
1-5/8
1,000
1,155
1,075
1,245
(9.5)
(41)
(4.4)
(5.1)
(4.8)
(5.5)
Table 19 - Hilti KWIK HUS-EZ in the top of ucracked concrete over metal deck1,2,3,4
Shear - Vn
Tension - Nn
Anchor
diameter
in. (mm)
Nominal
embed.
depth
in. (mm)
1/4
1-5/8
315
345
835
965
(6.4)
(41)
(1.4)
(1.5)
(3.7)
(4.3)
3/8
1-5/8
520
600
760
880
(9.5)
(41)
(2.3)
(2.7)
(3.4)
(3.9)
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Apply spacing, edge distance, and concrete thickness factors in tables 20 and 21 as necessary. Compare to
the steel values
in table 4. The lesser of the values is to be used for the design.
Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by a
as follows:
Tabular values are for static loads only. For seismic loads, multiply cracked concrete tabular values by the
following reduction factors:
242 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in tension
AN
Anchor
diameter da
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1-5/8
(41)
n/a
n/a
n/a
0.92
0.96
0.99
1.00
1-5/8
(41)
n/a
n/a
n/a
0.95
0.99
1.00
1-5/8
(41)
0.44
0.50
0.63
0.75
0.81
0.88
1.00
1-5/8
(41)
0.58
0.67
0.83
1.00
1-5/8
(41)
n/a
n/a
n/a
0.68
0.70
0.71
0.74
0.77
0.80
0.83
0.86
0.89
0.92
0.95
0.98
1.00
1-5/8
(41)
n/a
n/a
n/a
0.71
0.72
0.74
0.78
0.81
0.84
0.88
0.91
0.95
0.98
1.00
1-5/8
(41)
0.44
0.50
0.63
0.75
0.81
0.88
1.00
1-5/8
(41)
0.58
0.67
0.83
1.00
1-5/8
(41)
0.44
0.50
0.63
0.75
0.81
0.88
1.00
1-5/8
(41)
0.58
0.67
0.83
1.00
1-5/8
(41)
n/a
n/a
0.78
0.85
1-5/8
(41)
n/a
n/a
0.83
0.91
Nominal
embed. hnom
1-3/4
2
2-1/2
3
3-1/4
3-1/2
4
4-1/2
5
5-1/2
6
6-1/2
7
7-1/2
8
9
in.
(mm)
in.
(mm)
(44)
(51)
(64)
(76)
(83)
(89)
(102)
(114)
(127)
(140)
(152)
(165)
(178)
(191)
(203)
(229)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
II to edge
RV
Conc. thickness
factor in shear4
HV
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Table 21 - Load adjustment factors for KWIK HUS-EZ in the top of cracked concrete over metal deck
1,2
Spacing factor
in tension
AN
Anchor
diameter da
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
1/4
(6.4)
3/8
(9.5)
3.3.7
1-5/8
(41)
n/a
n/a
n/a
0.92
0.96
0.99
1.00
1-5/8
(41)
n/a
n/a
n/a
0.95
0.99
1.00
1-5/8
(41)
0.99
1.00
1-5/8
(41)
1.00
1-5/8
(41)
n/a
n/a
n/a
0.68
0.70
0.71
0.74
0.77
0.80
0.83
0.86
0.89
0.92
0.95
0.98
1.00
1-5/8
(41)
n/a
n/a
n/a
0.71
0.73
0.74
0.78
0.81
0.85
0.88
0.92
0.95
0.98
1.00
1-5/8
(41)
0.51
0.62
0.87
1.00
1-5/8
(41)
0.62
0.76
1.00
1-5/8
(41)
0.99
1.00
1-5/8
(41)
1.00
1-5/8
(41)
n/a
n/a
0.78
0.85
1-5/8
(41)
n/a
n/a
0.83
0.91
3.3.7
1-3/4
2
2-1/2
3
3-1/4
3-1/2
4
4-1/2
5
5-1/2
6
6-1/2
7
7-1/2
8
9
in.
(mm)
in.
(mm)
(44)
(51)
(64)
(76)
(83)
(89)
(102)
(114)
(127)
(140)
(152)
(165)
(178)
(191)
(203)
(229)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
3.3.8
Nominal
embed. hnom
1
2
3.3.1
toward edge
RV
II to edge
RV
Conc. thickness
factor in shear4
HV
3.3.9
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 243
Embedment
in.6
Loads @
ccr and scr
1 5/810
530
2 1/211
910
535
2 1/2
895
3 1/4
1,210
3/8
1/2
5/8
3/4
Minimum - Smin
in.7
2
0.70
1.00
0.70
0.80
10
12
Critical - scr
in.7
4
1 5/811
2 1/4
710
1,110
4 1/4
1,515
3 1/4
1,155
1,735
1,680
6 1/4
2,035
Edge distance
Load
reduction
factor at smin8
Critical - ccr
in.9
4
0.60
0.60
0.60
Table 23 Allowable shear loads for KWIK HUS-EZ installed in grout-filled masonry walls (lb)1,2,3,4,5
Spacing
Edge distance
Load reduction factor at cmin
Nominal
anchor Embedment
diameter
in.6
1/4
3/8
1/2
5/8
3/4
1 5/8
Load at ccr
and scr
675
2 1/2
840
1 5/8
1,140
2 1/2
1,165
3 1/4
2 1/4
3
2,055
Critical - Scr
in.7
Minimum - Smin
in.7
Load
reduction
factor at Smin8
1.00
Critical - ccr
in.9
Minimum - cmin
in.9
Load direction
perpendicular
to edge
Load direction
parallel
to edge
1.00
1.00
1.00
1.00
0.61
1.00
0.70
1.00
1,190
0.70
1.00
1,845
0.50
1.00
0.45
0.94
0.94
0.88
4 1/4
2,745
0.40
0.89
3 1/4
3,040
0.36
0.82
3,485
0.34
0.92
0.36
0.82
0.34
0.92
3,040
6 1/4
3,485
10
0.36
10
10
0.36
10
1 All values are for anchors installed in fully grouted masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units
may be lightweight, medium-weight or normal-weight.
2 Anchors may not be installed within one inch in any direction of a vertical joint.
3 Linear interpolation of load values between minimum spacing smin and critical spacing scr and between minimum edge distance cmin and
critical edge distance ccr is permitted.
Tapplied 5/3 Vapplied 5/3
Tapplied
Vapplied
4 For combined loading:
For 1/4-in. - + 1 For
3/8- through 3/4-in. - + 1
Tallowable
Vallowable
Tallowable
Vallowable
5 See figure 5 for anchor locations.
( )( )
6 Embedment depth is measured from the outside face of the concrete masonry embedment.
7 Critical spacing scr is the anchor spacing where full load values may be used. The minimum spacing smin is the minimum spacing for which
values are available and installation is recommended. Spacing is measured from the center of one anchor to the center of the adjacent
anchor.
8 Load reduction factors are multiplicative, both spacing and edge distance load reduction factors must be considered. Load values for
anchors installed at less than ccr or scr must be multiplied by the appropriate load reduction factor based on actual edge distance (c) or
spacing (s).
9 The critical edge distance ccr is the edge distance where full load values may be used. The minimum edge distance cmin is the minimum
edge distance for which values are available and installation is recommended. For tension, ccr equals cmin. Edge distance is measured from
the center of the anchor to the closest edge.
10 Load values must be reduced by 21% for installations within 1 1/4 inches of the bed joint.
11 Load values must be reduced by 13% for installations within 1 1/4 inches of the bed joint.
244 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3/8
1/2
Minimum
embedment
depth
in.
1 5/8
2 1/2
1 5/8
3 1/4
2 1/4
4 1/4
5/8
3/4
6 1/4
Edge
distance4
in.
1 1/2
3 3/4
1 1/2
3 3/4
1 1/2
3 3/4
1 1/2
3 3/4
1 3/4
3 3/4
1 3/4
3 3/4
1 3/4
3 3/4
3 3/4
Critical
spacing5
in.
Minimum
end
distance6
in.
10
10
12
12
Load direction
Tension
lb
Parallel
to edge of
masonry wall
Perpendicular
to edge of
masonry wall
205
205
355
390
245
245
465
540
390
610
540
750
975
975
975
180
275
345
415
345
345
490
800
460
525
885
1275
930
2190
2430
135
275
155
330
175
435
200
625
200
500
245
550
245
630
630
Table 25 KWIK HUS-EZ allowable loads installed in end of wall or vertical members of wall openings1,2,3
Nominal
anchor
diameter
1/4
3/8
1/2
5/8
3/4
1 5/8
2 1/2
1 5/8
3 1/4
2 1/4
4 1/4
5
6 1/4
Edge
distance4
in.
1 1/2
3 3/4
1 1/2
3 3/4
1 1/2
3 3/4
1 1/2
3 3/4
1 3/4
3 3/4
1 3/4
3 3/4
3 3/4
3 3/4
Critical
spacing5
in.
Minimum
end
distance6
in.
10
12
10
12
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Shear lb
Minimum
embedment
depth
in.
3.3.1
Load direction
Tension
lb
Parallel
to edge of
masonry wall
Perpendicular
to edge of
masonry wall
360
380
590
755
355
465
565
1020
500
525
650
1150
1605
1865
525
595
610
635
725
1010
875
1195
855
1100
925
1240
2215
2550
205
585
225
585
215
825
240
1050
260
1050
280
1050
1050
1050
3.3.8
3.3.9
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry
units may be lightweight, medium-weight or normal-weight conforming to ASTM C90. Allowable loads are calculated using safety factor of 5.
2 See figure 6 and 7 for allowable anchor installation locations on the top of grout-filled concrete masonry walls. Anchors may not be installed
within one inch of a vertical joint. See figure 7 for anchor installation locations in end-of-wall and vertical members of wall openings.
3 Anchors may not be installed within one inch in any direction of a vertical joint.
4 For load values at edge distances between listed values linear interpolation is permitted.
5 Critical spacing equals minimum spacing.
6 Minimum end distance applicable to top-of-wall and end-of-wall and does not apply for wall openings such as windows.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 245
Figure 5 Acceptable locations (shaded areas) for Hilti KWIK HUS-EZ anchors in grout-filled concrete masonry
246 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Minimum Embedment
Depth
KH-EZ 1/4x1-7/8
1/4
1-7/8
1-5/8
100
KH-EZ 1/4x2-5/8
1/4
2-5/8
2-1/2
100
KH-EZ 1/4x3
1/4
2-1/2
100
KH-EZ 1/4x3-1/2
1/4
3-1/2
2-1/2
100
KH-EZ 1/4x4
1/4
2-1/2
100
Description
KH-EZ 3/8x1-7/8
3/8
1-7/8
1-5/8
50
KH-EZ 3/8x2-1/8
3/8
2-1/8
1-5/8
50
KH-EZ 3/8x3
3/8
2-1/2
50
KH-EZ 3/8x3-1/2
3/8
3-1/2
2-1/2
50
KH-EZ 3/8x4
3/8
3-1/4
50
KH-EZ 3/8x5
3/8
3-1/4
30
KH-EZ 1/2x2-1/2
1/2
2-1/2
2-1/4
30
KH-EZ 1/2x3
1/2
2-1/4
30
KH-EZ 1/2x3-1/2
1/2
3-1/2
25
KH-EZ 1/2x4
1/2
25
KH-EZ 1/2x4-1/2
1/2
4-1/2
4 1/4
25
KH-EZ 1/2x5
1/2
4 1/4
25
KH-EZ 1/2x6
1/2
4-1/4
25
KH-EZ 5/8x3-1/2
5/8
3-1/2
3-1/4
15
KH-EZ 5/8x4
5/8
3-1/4
15
KH-EZ 5/8x5-1/2
5/8
5-1/2
3-1/4
15
KH-EZ 5/8x6-1/2
5/8
6-1/2
3-1/4
15
KH-EZ 5/8x8
5/8
3-1/4
15
KH-EZ 3/4x4-1/2
3/4
4-1/2
10
KH-EZ 3/4x5-1/2
3/4
5-1/2
10
KH-EZ 3/4x7
3/4
10
KH-EZ 3/4x8
3/4
10
KH-EZ 3/4x9
3/4
10
3.3.8
3.3.9
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
3.3.7
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 247
Notes
248 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.7.1
Product description
3.3.7.2
Material specifications
3.3.7.5
Design guidelines
3.3.1
3.3.7.2 Material
specifications
3.3.2
3.3.3
3.3.4
3.3.5
3.3.7.3 Technical
data
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
Listings/Approvals
ICC-ES (International Code Council)
ESR-3027
(Cracked & Uncracked Concrete)
City of Los Angeles
Research Report No. 25897
FM Approved
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 249
Setting
information
Symbol
Units
1/4
dbit
Nominal embedment
hnom
in.
1-5/8
Effective embedment
hef
in.
1.18
1.92
ho
in.
2-7/8
dh
Installation torque
1/4
in.
Tinst
2-1/2
3/8
ft-lb
(Nm)
(5)
in.
7/16
Wrench size
1 Tinst is the maximum installation torque that may be applied with a torque wrench.
Table 2 - Calculated ACI 318-11 Appendix D strength design capacity for single anchor in tension1,2,3,4,5
Lightweight over metal deck7
Normal-weight concrete6
'c= 2500 psi1
Anchor
size
1/4 x 1-5/8
1/4 x 2-1/2
Internal
thread
size
Nominal
embedment Uncracked Cracked
in.
concrete concrete
1/4-20
UNC
3/8-16
UNC
1/4-20
UNC
3/8-16
UNC
Seismic
Uncracked Cracked
concrete concrete
Seismic
Cracked
concrete
1-5/8
587
300
240
675
346
277
545
670
280
342
1-5/8
587
300
240
675
346
277
545
670
280
342
2-1/2
1,533
758
758
1,940
958
958
1,218
1,275
605
634
2-1/2
1,533
758
758
1,940
958
958
1,218
1,275
605
634
1
2
3
4
5
6
Based on single anchor with edge and spacing values greater than those given as critical values in table 1.
Based on lower value of concrete breakout or pullout strength.
These loads are factored resistance loads in accordance with chapter 9 of ACI 318-11.
Interpolation of values for other embedments is not permitted.
Minimum concrete thickness and edge distance must comply with table 1.
Tabular values for normal-weight conduct may be adjusted for higher compressive strengths using a multiplication factor of ('c /2,500) 0.3 for 1-5/8 in.
embedment and ('c /2,500) 0.5 for 1-5/8 in. embedment.
7 Tabular values for lightweight conduct may be adjusted for higher compressive strengths using a multiplication factor of ('c /3,000) 0.3 for 1-5/8 in. embedment
and ('c /3,000) 0.5 for 1-5/8 in. embedment.
Table 3 - KWIK HUS-EZ I (KH-EZ I) allowable stress design values for illustrative purposes1,2,3,4,5,6,7,8,9,10,11
Internal thread size
1/4
1
2
3
4
5
6
7
8
9
10
11
1-5/8
1.18
470
2-1/2
1.92
1,340
250 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1
3.3.2
3.3.3
1 A
nchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is
satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset
distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge
distance is also satisfied.
Table 4 - KWIK HUS EZ I (KH-EZ I) Allowable stress design tension values for installations in soffit of concrete
over steel deck floor and roof assemblies1,2,3,4,5,6,7,8,9,10,11
1/4
1
2
3
4
5
6
7
8
9
10
11
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
Tension
lb
Nominal embedment
in.
Effective embedment
in.
Upper flute
Lower flute
3.3.9
1-5/8
1.18
466
378
3.3.9
2-1/2
1.92
885
846
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 251
FM maximum
pipe diameter
in.
1,475
1-5/8
3/8-16 UNC
2-1/2
1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953.
Table 6 - KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1,2
Hanger rod size
1/4-20 UNC
3/8-16 UNC
Min. effective
embedment hef
in.
Allowable load3
Tension lb
1-3/8
455
Ultimate load
Shear lb4,5
485
755
Tension lb
1,810
Shear lb4,5
1,930
3,025
1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the
cable with the hollow core plank supplier to confirm admissible anchor location.
2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials.
Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance.
3 Allowable loads calculated with a factor of safety of 4
4 The bottom of the shear plane adjacent to the top of the coupler.
5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-I Screw Anchor. The minimum tensile strength of the
screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength.
Internal thread
length
Hole
diameter
Minimum
embedment
Qty / box
1/4
3/8
1/4
1-5/8
100
1/4
3/8
1/4
2-1/2
100
3/8
7/16
1/4
1-5/8
100
3/8
7/16
1/4
2-1/2
100
Description
252 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Guide specifications
Torque-controlled expansion anchor
shall be Hilti KWIK Bolt 3. KWIK Bolt 3
anchors meet the description of Federal
Specification A-A 1923A, Type 4. The
anchor bears a length identification
mark embossed on the impact section
(dog point) of the anchor identifying the
anchor as a Hilti KWIK Bolt 3.
Carbon steel Kwik Bolt 3 anchors have
a carbon steel anchor body, carbon
steel nut and carbon steel washer.
Anchor body, nut and washer have zinc
plating conforming to ASTM B633 with
a minimum thickness of 5 m.
AISI Type 304 stainless steel Kwik Bolt
3 anchors have an anchor body, nut
and washer That conform to AISI Type
304. The expansion wedges conform
to either AISI Type 304 stainless steel
or either AISI Type 316 stainless steel.
AISI Type 316 stainless steel Kwik Bolt
3 anchors have an anchor body, nut
and washer That conform to AISI Type
316. The expansion wedges conform
to AISI Type 316 stainless steel.
Hot-dip galvanized Kwik Bolt 3 anchors
have a carbon steel anchor body,
carbon steel nut and carbon steel
washer. Anchor body, nut and washer
have zinc plating conforming to ASTM
A153 with an average thickness of 53
m. The expansion wedges conform to
either AISI Type 304 stainless steel or
either AISI Type 316 stainless steel.
3.3.8.1
Product description
3.3.8.2
Material specifications
3.3.8.3
Technical data
3.3.8.4
Installation instructions
3.3.8.5
Ordering information
Impact section
(dog point)
Nut
Washer
3.3.1
3.3.2
3.3.3
Anchor
thread
3.3.4
3.3.5
Anchor
body
3.3.6
Expansion
element
(wedges)
3.3.8
Expansion
cone
3.3.9
3.3.7
3.3.9
3.3.9
Listings/Approvals
ICC-ES (International Code Council)
ESR-2302
ICC-ES (International Code Council)
ESR-1385 Grout-filled concrete masonry
City of Los Angeles
Research Report No. 25577
Research Report No. 25577M
for masonry
FM (Factory Mutual)
Pipe Hanger Components for
Automatic Sprinkler for 3/8 through 3/4
UL LLC
UL 203 Pipe Hanger Equipment for Fire
Protection Services for 3/8 through 3/4
Qualified under an NQA-1 Nuclear
Quality Program
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 253
Carbon steel
Hot-dip galvanized
Stainless steel
1/4
2,900
no offering
2,900
3/8
7,200
no offering
7,200
1/2
12,400
12,400
12,400
5/8
19,600
19,600
21,900
3/4
28,700
28,700
no offering
1 Bolt fracture loads are determined by testing in a universal tensile machine for quality
control at the manufacturing facility. These loads are not intended for design use. See
tables 4 and 12 for the steel design strengths of carbon steel and stainless steel,
respectively.
2 All 3/4-in. stainless steel, 3/4x12 carbon steel, all 1-in. carbon steel and all 1-in. stainless
steel material strengths specified by the tensile and yield strengths expressed in (ksi).
Bolt fracture loads not applicable for these models.
254 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
Figure 1 - KWIK Bolt 3 installation
3.3.9
3.3.9
dbit
Minimum nominal
embedment
hnom
Minimum effective
embedment
hef
ho
dh
Anchor length
Installation torque
Wrench size
3.3.9
Setting
information
Tinst
Units
in.
1/4
3/8
1/2
5/8
3/4
1/4
3/8
1/2
5/8
3/4
1-3/4
2-3/8
2-1/4
(mm)
3-5/8
3-1/2
4-3/8
(44)
(60)
(57)
in.
1-1/2
(92)
(89)
3-1/4
3-1/8
(mm)
(38)
(51)
(51)
(83)
(79)
(102)
in.
2-5/8
2-5/8
3-7/8
4-3/4
(67)
(102)
(98)
(121)
(114)
(mm)
(51)
(67)
in.
5/16
7/16
9/16
ft-lb
20
40
3.3.9
4-1/4
5-5/8
4-5/8
(111)
(108)
(143)
117
162
3-3/4
5-3/4
(95)
(127)
(102)
(146)
4-1/2
5-3/4
6-3/4
(146)
(127)
11/16
6-3/8
(171)
13/16
1-1/8
110
150
(Nm)
(5)
(27)
(54)
(81)
(149)
(203)
in.
7/16
9/16
3/4
15/16
1-1/8
1-1/2
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 255
1/2
5/8
3/4
1-1/2
1-3/4
1,025
1,080
1,180
1,330
1,545
1,690
1,950
(38)
(44)
(4.6)
(4.8)
(5.2)
(5.9)
(6.9)
(7.5)
(8.7)
2,390
(10.6)
2-3/8
2,205
2,415
2,790
3,420
2,375
2,605
3,005
3,680
(51)
(60)
(9.8)
(10.7)
(12.4)
(15.2)
(10.6)
(11.6)
(13.4)
(16.4)
2-1/4
2,205
2,415
2,790
3,420
2,375
2,605
3,005
3,680
(51)
(57)
(9.8)
(10.7)
(12.4)
(15.2)
(10.6)
(11.6)
(13.4)
(16.4)
3-1/4
3-1/2
4,420
4,840
5,590
6,845
9,845
10,785
12,450
15,250
(83)
(89)
(19.7)
(21.5)
(24.9)
(30.4)
(43.8)
(48.0)
(55.4)
(67.8)
3-1/8
3-1/2
4,310
4,720
5,450
6,675
9,280
10,165
11,740
14,380
(79)
(89)
(19.2)
(21.0)
(24.2)
(29.7)
(41.3)
(45.2)
(52.2)
(64.0)
4-3/8
6,240
6,835
7,895
9,665
13,440
14,725
17,000
20,820
(102)
(111)
(27.8)
(30.4)
(35.1)
(43.0)
(59.8)
(65.5)
(75.6)
(92.6)
3-3/4
4-1/4
5,665
6,205
7,165
8,775
12,200
13,365
15,430
18,900
(95)
(108)
(25.2)
(27.6)
(31.9)
(39.0)
(54.3)
(59.5)
(68.6)
(84.1)
5-1/2
6,880
7,535
8,705
10,660
18,785
20,575
23,760
29,100
(127)
(140)
(30.6)
(33.5)
(38.7)
(47.4)
(83.6)
(91.5)
(105.7)
(129.4)
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Apply spacing, edge distance, and concrete thickness factors in tables 6 to 10 as necessary. Compare to steel values in table 4.
The lesser of the values is to be used for the design.
Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by a as follows:
for sand-lightweight, a = 0.68; for all-lightweight, a = 0.60
Table 4 - Steel design strength for Hilti KWIK Bolt 3 carbon steel anchors1,2
Nominal anchor
diameter
1/4
3/8
Nominal
embedment
in. (mm)
Tensile3
Nsa
lb (kN)
Shear4
Vsa
lb (kN)
1-3/4
1,590
1,065
(44)
(7.1)
(4.7)
2-3/8
4,770
2,905
(60)
(21.2)
(12.9)
2-1/4
1/2
(57)
3-1/2
4,315
8,745
(38.9)
(89)
(19.2)
4,390
(19.5)
3-1/2
5/8
(89)
4-3/8
13,515
(60.1)
7,950
(35.4)
(111)
4-1/4
3/4
(108)
5-1/2
10,180
19,080
(84.9)
(140)
1
KWIK Bolt 3 carbon steel anchors are to be considered ductile steel elements.
3
4
(45.3)
10,785
(48.0)
Shear values determined by static shear tests with Vsa < 0.60 Ase,V futa as noted in ACI 318 Appendix D.
256 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
cmin,2
Case 2
(smin,1 smin,2)
s smin,2 + ___________ (c cmin,2)
(cmin,1 cmin,2)
cmin,1
Case 1
smin,2
spacing s
Figure 2
cmin,1 at smin,1
sdesign
cmin,2 at smin,2
cdesign
Concrete
Edge
smin,1
edge distance c
Symbol
hef
hmin
Case 1
Case 2
c min,1
for s min,1
cmin,2
for s min,2
Units
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
1/4
3/8
1/2
5/8
1-1/2
2
2
3-1/4
(38)
(51)
(51)
(83)
4
4
5
4
5
6
8
(102) (102) (127) (102) (127) (152) (203)
1-3/8
2
1-1/2 2-1/8
2
1-5/8 1-5/8
(35)
(51)
(38)
(54)
(51)
(41)
(41)
1-3/4 2-7/8 3-1/2 4-7/8 4-3/4 4-1/4
4
(44)
(73)
(89) (124) (121) (108) (102)
1-5/8 2-3/8 2/3/8 2-5/8 2-3/8 2-1/4
2
(41)
(60)
(60)
(67)
(60)
(57)
(51)
1-1/4 1-3/4 1-3/4 2-1/2 2-1/4
2
1-7/8
(32)
(44)
(44)
(64)
(57)
(51)
(48)
3-1/8
(79)
5
(127)
2-1/4
(57)
5-1/4
(133)
3-1/8
(79)
2-3/8
(60)
4
(102)
3.3.1
3/4
3-3/4
(95)
6
8
6
8
(152) (203) (152) (203)
1-3/4 1-3/4 2-3/4 2-5/8
(44)
(44)
(70)
(67)
4-3/4
4
6-7/8 6-1/2
(121) (102) (175) (165)
2-3/8 2-1/4 3-3/4 3-3/8
(60)
(57)
(95)
(86)
2-1/8 2-1/8 3-3/4 3-3/8
(54)
(54)
(95)
(86)
5
(127)
8
(203)
2-1/2
(64)
6-3/8
(162)
3-3/8
(86)
3-1/4
(83)
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
1-3/4
(44)
0.64
0.65
0.67
0.72
0.83
0.89
0.94
1.00
1-3/4
(44)
n/a
0.58
0.61
0.75
1.00
1-3/4
(44)
0.56
0.57
0.57
0.60
0.65
0.67
0.70
0.72
0.74
0.77
0.79
0.84
0.89
0.94
0.99
1.00
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Table 6 - Load adjustment factors for 1/4-in. diameter KWIK Bolt 3 carbon steel anchor in uncracked concrete1,2
Spacing factor
in tension
AN
3.3.3
3.3.9
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge .distance c, where cmin,1 < c < cmin,2 will determine the permissible spacings.
1/4-in. KB3
carbon steel
uncracked concrete
Embedment hnom
in.
(mm)
1-1/4
(32)
1-3/8
(35)
1-1/2
(38)
2
(51)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
5-1/2
(140)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
3.3.2
II To edge
RV
1-3/4
(44)
n/a
0.26
0.29
0.45
0.83
1.00
1-3/4
(44)
n/a
0.51
0.58
0.75
1.00
Concrete
thickness factor
in shear4
HV
1-3/4
(44)
n/a
n/a
n/a
n/a
n/a
n/a
0.88
0.94
0.99
1.00
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 257
Embedment hnom
in.
(mm)
1-3/4
(44)
2
(51)
2-1/2
(64)
3
(76)
3-1/4
(83)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
2-3/8
(60)
0.65
0.67
0.71
0.75
0.77
0.79
0.83
0.88
0.92
1.00
2-3/8
(60)
n/a
0.50
0.58
0.67
0.72
0.78
0.89
1.00
2-3/8
(60)
0.57
0.58
0.60
0.62
0.63
0.64
0.67
0.69
0.71
0.75
0.79
0.83
0.87
0.91
0.95
1.00
Toward edge
RV
II To edge
RV
2-3/8
(60)
n/a
0.35
0.49
0.64
0.72
0.81
0.99
1.00
2-3/8
(60)
n/a
0.50
0.58
0.67
0.72
0.81
0.99
1.00
Concrete
thickness factor
in shear4
HV
2-3/8
(60)
n/a
n/a
n/a
n/a
n/a
n/a
0.81
0.86
0.91
1.00
Table 8 - Load adjustment factors for 1/2-in. diameter KWIK Bolt 3 carbon steel anchor in uncracked concrete1,2
Edge distance in shear
1/2-in. KB3
carbon steel
uncracked concrete
Embedment hnom
in.
(mm)
1-5/8
(41)
2
(51)
2-1/8
(54)
2-1/2
(64)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
> 24
(610)
1
2
3
4
Spacing factor
in tension
AN
2-1/4
(57)
n/a
n/a
n/a
0.71
0.75
0.79
0.83
0.88
0.92
1.00
3-1/2
(89)
n/a
0.60
0.61
0.63
0.65
0.68
0.71
0.73
0.76
0.81
0.86
0.91
0.96
1.00
Edge distance
factor in tension
RN
2-1/4
(57)
n/a
n/a
0.48
0.54
0.62
0.72
0.82
0.92
1.00
3-1/2
(89)
0.39
0.42
0.43
0.47
0.52
0.57
0.62
0.68
0.74
0.89
1.00
Spacing factor
in shear3
AV
2-1/4
(57)
n/a
n/a
n/a
0.61
0.63
0.65
0.68
0.70
0.72
0.76
0.81
0.85
0.89
0.94
0.98
1.00
3-1/2
(89)
n/a
0.54
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.61
0.63
0.64
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
0.93
Toward edge
RV
2-1/4
(57)
n/a
n/a
0.42
0.53
0.70
0.88
1.00
3-1/2
(89)
0.07
0.10
0.11
0.14
0.19
0.23
0.29
0.34
0.40
0.53
0.66
0.81
0.97
1.00
II To edge
RV
2-1/4
(57)
n/a
n/a
0.48
0.54
0.70
0.88
1.00
3-1/2
(89)
0.15
0.20
0.22
0.28
0.37
0.47
0.57
0.68
0.74
0.89
1.00
Concrete
thickness factor
in shear4
HV
2-1/4
(57)
n/a
n/a
n/a
n/a
n/a
n/a
0.84
0.89
0.94
1.00
3-1/2
(89)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.89
0.93
1.00
258 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Embedment hnom
in.
(mm)
1-3/4
(44)
2
(51)
2-1/8
(54)
2-1/4
(57)
2-3/8
(60)
2-1/2
(64)
3
(76)
4
(102)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
> 30
(762)
Spacing factor
in tension
AN
3-1/2
(89)
n/a
n/a
n/a
n/a
0.63
0.63
0.66
0.71
0.77
0.82
0.87
0.93
0.98
1.00
4-3/8
(111)
n/a
n/a
0.59
0.59
0.60
0.60
0.63
0.67
0.71
0.75
0.79
0.83
0.88
0.92
0.96
1.00
Edge distance
factor in tension
RN
3-1/2
(89)
n/a
n/a
n/a
0.39
0.40
0.41
0.46
0.55
0.67
0.80
0.93
1.00
4-3/8
(111)
0.32
0.34
0.34
0.35
0.36
0.37
0.40
0.47
0.55
0.63
0.74
0.84
0.95
1.00
Spacing factor
in shear3
AV
3-1/2
(89)
n/a
n/a
n/a
n/a
0.55
0.55
0.56
0.58
0.60
0.62
0.64
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.85
0.89
0.97
1.00
4-3/8
(111)
n/a
n/a
0.53
0.54
0.54
0.54
0.55
0.56
0.58
0.59
0.61
0.63
0.64
0.66
0.67
0.69
0.72
0.75
0.78
0.82
0.88
0.97
4-3/8
(111)
0.07
0.08
0.09
0.10
0.11
0.12
0.15
0.23
0.33
0.43
0.54
0.66
0.79
0.92
1.00
II to edge
RV
3-1/2
(89)
n/a
n/a
n/a
0.27
0.30
0.32
0.42
0.55
0.67
0.80
0.93
1.00
4-3/8
(111)
0.14
0.17
0.18
0.20
0.21
0.23
0.30
0.47
0.55
0.63
0.74
0.84
0.95
1.00
Conc. thickness
factor in shear4
HV
3-1/2
(89)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.69
0.74
0.79
0.84
0.89
0.93
0.97
1.00
4-3/8
(111)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.67
0.71
0.75
0.80
0.83
0.87
0.94
1.00
Embedment hnom
in.
(mm)
2-1/2
(64)
2-3/4
(70)
3
(76)
3-1/4
(83)
3-1/2
(89)
3-3/4
(95)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
30
(762)
> 36
(914)
1
2
3
4
Spacing factor
in tension
AN
4-1/4
(108)
n/a
n/a
n/a
n/a
n/a
0.67
0.68
0.70
0.72
0.77
0.81
0.86
0.90
0.94
0.99
1.00
5-1/2
(140)
n/a
n/a
n/a
0.61
0.62
0.63
0.63
0.65
0.67
0.70
0.73
0.77
0.80
0.83
0.87
0.90
0.97
1.00
Edge distance
factor in tension
RN
4-1/4
(108)
n/a
0.36
0.38
0.40
0.41
0.43
0.45
0.49
0.53
0.62
0.72
0.82
0.92
1.00
5-1/2
(140)
0.42
0.44
0.45
0.47
0.49
0.50
0.52
0.56
0.59
0.67
0.75
0.84
0.95
1.00
Spacing factor
in shear3
AV
4-1/4
(108)
n/a
n/a
n/a
n/a
n/a
0.57
0.57
0.58
0.59
0.60
0.62
0.64
0.66
0.67
0.69
0.71
0.74
0.78
0.81
0.85
0.92
1.00
5-1/2
(140)
n/a
n/a
n/a
0.54
0.55
0.55
0.55
0.56
0.57
0.58
0.59
0.61
0.62
0.64
0.65
0.66
0.69
0.72
0.74
0.77
0.82
0.91
0.99
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
Table 10 - Load adjustment factors for 3/4-in. diameter KWIK Bolt 3 carbon steel anchor in uncracked concrete1,2
3/4-in. KB3
carbon steel
uncracked concrete
3.3.1
5-1/2
(140)
0.09
0.11
0.12
0.14
0.15
0.17
0.18
0.22
0.26
0.34
0.43
0.52
0.62
0.73
0.84
0.96
1.00
II to edge
RV
4-1/4
(108)
n/a
0.31
0.35
0.39
0.41
0.43
0.45
0.49
0.53
0.62
0.72
0.82
0.92
1.00
5-1/2
(140)
0.18
0.21
0.24
0.27
0.30
0.34
0.37
0.44
0.52
0.67
0.75
0.84
0.95
1.00
3.3.9
Conc. thickness
factor in shear4
HV
4-1/4
(108)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.70
0.75
0.79
0.83
0.87
0.91
0.99
1.00
5-1/2
(140)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.70
0.74
0.77
0.81
0.87
0.93
0.99
1.00
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 259
1/2
5/8
3/4
1-1/2
1-3/4
730
770
840
950
1,545
1,690
1,950
2,390
(38)
(44)
(3.2)
(3.4)
(3.7)
(4.2)
(6.9)
(7.5)
(8.7)
(10.6)
2-3/8
1,925
2,110
2,440
2,985
2,375
2,605
3,005
3,680
(51)
(60)
(8.6)
(9.4)
(10.9)
(13.3)
(10.6)
(11.6)
(13.4)
(16.4)
2-1/4
2,150
2,355
2,720
3,335
2,375
2,605
3,005
3,680
(51)
(57)
(9.6)
(10.5)
(12.1)
(14.8)
(10.6)
(11.6)
(13.4)
(16.4)
3-1/4
3-1/2
3,920
4,295
4,960
6,070
9,845
10,785
12,450
15,250
(83)
(89)
(17.4)
(19.1)
(22.1)
(27.0)
(43.8)
(48.0)
(55.4)
(67.8)
3-1/8
3-1/2
4,050
4,435
5,120
6,275
9,280
10,165
11,740
14,380
(79)
(89)
(18.0)
(19.7)
(22.8)
(27.9)
(41.3)
(45.2)
(52.2)
(64.0)
4-3/8
5,090
5,575
6,440
7,885
13,440
14,725
17,000
20,820
(102)
(111)
(22.6)
(24.8)
(28.6)
(35.1)
(59.8)
(65.5)
(75.6)
(92.6)
3-3/4
4-1/4
5,560
6,090
7,035
8,615
12,200
13,365
15,430
18,900
(95)
(108)
(24.7)
(27.1)
(31.3)
(38.3)
(54.3)
(59.5)
(68.6)
(84.1)
5-1/2
7,040
7,710
8,905
10,905
18,785
20,575
23,760
29,100
(127)
(140)
(31.3)
(34.3)
(39.6)
(48.5)
(83.6)
(91.5)
(105.7)
(129.4)
4-1/2
6,240
6,835
7,895
9,665
13,440
14,725
17,000
20,820
(102)
(114)
(27.8)
(30.4)
(35.1)
(43.0)
(59.8)
(65.5)
(75.6)
(92.6)
5-3/4
6-1/4
10,110
11,070
12,785
15,660
23,165
25,375
29,300
35,885
(146)
(159)
(45.0)
(49.2)
(56.9)
(69.7)
(103.0)
(112.9)
(130.3)
(159.6)
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Apply spacing, edge distance, and concrete thickness factors in tables 14 to 19 as necessary. Compare to steel values in table 12.
The lesser of the values is to be used for the design.
Tabular values are for normal-weight concrete only. For lightweight concrete multiply design strength by a as follows:
for sand-lightweight, a = 0.68; for all-lightweight, a = 0.60
260 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Nominal
embedment
in. (mm)
Tensile 3
Nsa
lb (kN)
Shear 4
Vsa
lb (kN)
1-3/4
1,725
1,090
(44)
(7.7)
(4.8)
2-3/8
5,175
3,235
(60)
(23.0)
(14.4)
2-1/4
1/2
5/8
3/4
(57)
2,725
9,490
(42.2)
(12.1)
4,510
3.3.1
(89)
(20.1)
3-1/2
5,820
3.3.2
3-1/2
(89)
4-3/8
14,665
(65.2)
(25.9)
9,295
(111)
(41.3)
4-1/4
7,735
(108)
5-1/2
16,200
(72.1)
3.3.5
(34.4)
3.3.6
15,305
3.3.7
(68.1)
4-1/2
8,130
3.3.8
(36.2)
3.3.9
(114)
6-1/4
31,735
(141.2)
17,775
(79.1)
KWIK Bolt 3 stainless steel anchors are to be considered ductile steel elements.
3.3.4
(140)
(159)
3.3.3
3.3.9
3.3.9
Shear values determined by static shear tests with Vsa < 0.60 Ase,V futa as noted
in ACI 318 Appendix D.
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 261
cmin,2
Case 2
(smin,1 smin,2)
s smin,2 + ___________ (c cmin,2)
(cmin,1 cmin,2)
cmin,1
Case 1
smin,2
spacing s
Figure 3
cmin,1 at smin,1
sdesign
cmin,2 at smin,2
cdesign
Concrete
Edge
smin,1
edge distance c
Symbol Units
Effective minimum
embedment
hef
Minimum member
thickness
hmin
Case 1
Case 2
c min,1
for s min,1
cmin,2
for s min,2
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
1/4
3/8
1/2
1-1/2
2
2
3-1/4
(38)
(51)
(51)
(83)
4
4
5
4
6
6
8
(102) (102) (127) (102) (152) (152) (203)
1-3/8
2
1-5/8 2-1/2 1-7/8 1-5/8 1-5/8
(35)
(51)
(41)
(68)
(48)
(41)
(41)
1-3/4
4
3-5/8
5
4-5/8 4-1/2 4-1/4
(44) (102) (92) (127) (117) (114) (108)
1-5/8 1-3/4 2-1/2 2-7/8 2-3/8 2-3/8 2-1/8
(41)
(83)
(64)
(73)
(60)
(60)
(54)
1-1/4
2
1-3/4 2-1/2 2-1/4 2-1/8 1-7/8
(32)
(51)
(44)
(64)
(57)
(54)
(48)
5/8
3-1/8
(79)
5
(127)
3-1/4
(83)
5-5/8
(143)
3-7/8
(98)
3-1/8
(79)
4
(102)
6
(152)
2-1/2
(64)
5-1/4
(133)
3
(76)
2-1/8
(54)
8
(203)
2-1/2
(64)
5
(127)
2-3/4
(70)
4
(54)
3/4
3-3/4
(95)
6
(152)
3-1/4
(83)
7
(178)
4-1/8
(105)
3-1/2
(102)
8
(203)
3
(76)
6-7/8
(175)
3-3/4
(95)
3-1/2
(89)
1
5
(127)
8
(203)
2-7/8
(73)
6-5/8
(168)
3-3/4
(95)
3-1/2
(89)
4
(102)
8
(203)
3/1/02
(89)
6-3/4
(172)
4-1/4
(108)
5
(127)
5-3/4
(146)
10
(254)
3
(76)
6-3/4
(172)
3-3/4
(95)
4-3/4
(121)
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge .distance c, where cmin,1 < c < cmin,2 will determine the permissible spacings.
Table 14 - Load adjustment factors for 1/4-in. diameter KWIK Bolt 3 stainless steel anchor in uncracked concrete1,2
1/4-in. KB3
stainless steel
uncracked uoncrete
Embedment hnom
in.
(mm)
1-1/4
(32)
1-3/8
(35)
1-1/2
(38)
2
(51)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
5-1/2
(140)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
1
2
3
4
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
1-3/4
(44)
0.64
0.65
0.67
0.72
0.83
0.89
0.94
1.00
1-3/4
(44)
n/a
0.53
0.56
0.68
1.00
1-3/4
(44)
0.56
0.57
0.57
0.60
0.65
0.67
0.70
0.72
0.74
0.77
0.79
0.84
0.89
0.94
0.99
1.00
II to edge
RV
1-3/4
(44)
n/a
0.26
0.29
0.45
0.83
1.00
1-3/4
(44)
n/a
0.51
0.56
0.68
1.00
Concrete
thickness factor
in shear4
HV
1-3/4
(44)
n/a
n/a
n/a
n/a
n/a
n/a
0.88
0.94
0.99
1.00
262 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
Spacing factor
in shear3
AV
2-3/8
(60)
0.67
0.71
0.75
0.79
0.83
0.88
0.92
1.00
2-3/8
(60)
0.51
0.60
0.69
0.80
0.91
1.00
2-3/8
(60)
0.58
0.60
0.62
0.64
0.67
0.69
0.71
0.75
0.79
0.83
0.87
0.91
0.95
1.00
Embedment hnom
in.
(mm)
2
(51)
2-1/2
(64)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
toward edge
RV
II to edge
RV
2-3/8
(60)
0.35
0.49
0.64
0.81
0.99
1.00
2-3/8
(60)
0.51
0.60
0.69
0.81
0.99
1.00
Concrete
thickness factor
in shear4
HV
2-3/8
(60)
n/a
n/a
n/a
n/a
0.81
0.86
0.91
1.00
Embedment hnom
in.
(mm)
1-5/8
(41)
2
(51)
2-1/8
(54)
2-1/2
(64)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
> 24
(610)
1
2
3
4
Spacing factor
in tension
AN
Edge distance
factor in tension
RN
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
Table 16 - Load adjustment factors for 1/2-in. diameter KWIK Bolt 3 stainless steel anchor in uncracked concrete1,2
1/2-in. KB3
stainless steel
uncracked concrete
3.3.1
Spacing factor
in shear3
AV
toward edge
RV
II to edge
RV
Concrete
thickness factor
in shear4
HV
2-1/4
3-1/2
2-1/4
3-1/2
2-1/4
3-1/2
2-1/4
3-1/2
2-1/4
3-1/2
2-1/4
3-1/2
(57)
n/a
n/a
n/a
0.71
0.75
0.79
0.83
0.88
0.92
1.00
(89)
n/a
n/a
0.61
0.63
0.65
0.68
0.71
0.73
0.76
0.81
0.86
0.91
0.96
1.00
(57)
n/a
n/a
n/a
0.54
0.62
0.72
0.82
0.92
1.00
(89)
0.39
0.42
0.43
0.47
0.52
0.57
0.62
0.68
0.74
0.89
1.00
(57)
n/a
n/a
n/a
0.61
0.63
0.65
0.68
0.70
0.72
0.76
0.81
0.85
0.89
0.94
0.98
1.00
(89)
n/a
n/a
0.54
0.55
0.55
0.56
0.57
0.58
0.59
0.61
0.63
0.64
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
0.93
(57)
n/a
n/a
n/a
0.53
0.70
0.88
1.00
(89)
0.07
0.10
0.11
0.14
0.19
0.23
0.29
0.34
0.40
0.53
0.66
0.81
0.97
1.00
(57)
n/a
n/a
n/a
0.54
0.70
0.88
1.00
(89)
0.15
0.20
0.22
0.28
0.37
0.47
0.57
0.68
0.74
0.89
1.00
(57)
n/a
n/a
n/a
n/a
n/a
n/a
0.84
0.89
0.94
1.00
(89)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.89
0.93
1.00
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 263
Embedment hnom
in.
(mm)
2-1/8
(54)
2-1/2
(64)
3
(76)
3-1/8
(79)
3-1/4
(83)
3-1/2
(89)
4
(102)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
> 30
(762)
Spacing factor
in tension
AN
3-1/2
(89)
n/a
n/a
n/a
0.67
0.67
0.69
0.71
0.77
0.82
0.87
0.93
0.98
1.00
4-3/8
(111)
0.59
0.60
0.63
0.63
0.64
0.65
0.67
0.71
0.75
0.79
0.83
0.88
0.92
0.96
1.00
Edge distance
factor in tension
RN
3-1/2
(89)
n/a
n/a
n/a
n/a
0.49
0.51
0.56
0.68
0.81
0.95
1.00
4-3/8
(111)
n/a
0.37
0.40
0.41
0.42
0.44
0.47
0.55
0.63
0.74
0.84
0.95
1.00
Spacing factor
in shear3
AV
3-1/2
(89)
n/a
n/a
n/a
0.56
0.56
0.57
0.58
0.60
0.62
0.64
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.85
0.89
0.97
1.00
4-3/8
(111)
0.53
0.54
0.55
0.55
0.55
0.56
0.56
0.58
0.59
0.61
0.63
0.64
0.66
0.67
0.69
0.72
0.75
0.78
0.82
0.88
0.97
4-3/8
(111)
n/a
0.12
0.15
0.16
0.17
0.19
0.23
0.33
0.43
0.54
0.66
0.79
0.92
1.00
II to edge
RV
3-1/2
(89)
n/a
n/a
n/a
n/a
0.47
0.51
0.56
0.68
0.81
0.95
1.00
4-3/8
(111)
n/a
0.23
0.30
0.32
0.34
0.38
0.47
0.55
0.63
0.74
0.84
0.95
1.00
Concrete
thickness factor
in shear4
HV
3-1/2
(89)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.69
0.74
0.79
0.84
0.89
0.93
0.97
1.00
4-3/8
(111)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.67
0.71
0.75
0.80
0.83
0.87
0.94
1.00
Table 18 - Load adjustment factors for 3/4-in. diameter KWIK Bolt 3 stainless steel anchor in uncracked concrete1,2
3/4-in. KB3
stainless steel
uncracked concrete
Embedment hnom
in.
(mm)
2-7/8
(73)
3
(76)
3-1/4
(83)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
30
(762)
> 36
(914)
1
2
3
4
Spacing factor
in tension
AN
4-1/4
(108)
n/a
n/a
n/a
n/a
0.68
0.70
0.72
0.77
0.81
0.86
0.90
0.94
0.99
1.00
5-1/2
(140)
n/a
n/a
n/a
0.62
0.63
0.65
0.67
0.70
0.73
0.77
0.80
0.83
0.87
0.90
0.97
1.00
Edge distance
factor in tension
RN
4-1/4
(108)
n/a
n/a
0.37
0.39
0.42
0.45
0.49
0.57
0.67
0.76
0.86
0.95
1.00
5-1/2
(140)
0.43
0.44
0.46
0.47
0.51
0.54
0.58
0.65
0.73
0.82
0.92
1.00
Spacing factor
in shear3
AV
4-1/4
(108)
n/a
n/a
n/a
n/a
0.57
0.58
0.59
0.60
0.62
0.64
0.66
0.67
0.69
0.71
0.74
0.78
0.81
0.85
0.92
1.00
5-1/2
(140)
n/a
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.59
0.61
0.62
0.64
0.65
0.66
0.69
0.72
0.74
0.77
0.82
0.91
0.99
5-1/2
(140)
0.11
0.12
0.14
0.15
0.18
0.22
0.26
0.34
0.43
0.52
0.62
0.73
0.84
0.96
1.00
II to edge
RV
4-1/4
(108)
n/a
n/a
0.37
0.39
0.42
0.45
0.49
0.57
0.67
0.76
0.91
1.00
5-1/2
(140)
0.23
0.24
0.27
0.30
0.37
0.44
0.52
0.65
0.73
0.82
0.92
1.00
Concrete
thickness factor
in shear4
HV
4-1/4
(108)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.70
0.75
0.79
0.83
0.87
0.91
0.99
1.00
5-1/2
(140)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.70
0.74
0.77
0.81
0.87
0.93
0.99
1.00
264 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
1-in. KB3
stainless steel
uncracked concrete
Embedment hnom
in.
(mm)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
4-3/4
(121)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
30
(762)
> 36
(914)
1
2
3
4
Spacing factor
in tension
AN
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
0.71
0.75
0.79
0.83
0.88
0.92
0.96
1.00
6-1/4
(159)
n/a
n/a
n/a
n/a
0.64
0.64
0.67
0.70
0.73
0.76
0.79
0.82
0.85
0.91
0.96
1.00
Edge distance
factor in tension
RN
4-1/2
(114)
n/a
0.42
0.45
0.49
0.50
0.52
0.60
0.70
0.80
0.90
1.00
6-1/4
(159)
0.43
0.45
0.48
0.51
0.53
0.54
0.60
0.67
0.74
0.82
0.91
1.00
Spacing factor
in shear3
AV
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
0.59
0.60
0.62
0.64
0.65
0.67
0.69
0.70
0.74
0.77
0.81
0.84
0.91
1.00
6-1/4
(159)
n/a
n/a
n/a
n/a
0.56
0.56
0.57
0.58
0.60
0.61
0.62
0.63
0.64
0.67
0.69
0.71
0.74
0.79
0.86
0.93
6-1/4
(159)
0.10
0.12
0.15
0.18
0.20
0.21
0.28
0.35
0.43
0.51
0.60
0.69
0.79
1.00
II to edge
RV
4-1/2
(114)
n/a
0.42
0.45
0.49
0.50
0.52
0.60
0.70
0.80
0.90
1.00
6-1/4
(159)
0.20
0.25
0.30
0.36
0.39
0.43
0.56
0.67
0.74
0.82
0.91
1.00
Concrete
thickness factor
in shear4
HV
4-1/2
(114)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.74
0.78
0.83
0.87
0.91
0.98
1.00
6-1/4
(159)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.69
0.72
0.76
0.82
0.87
0.92
0.98
1.00
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 265
1/2
5/8
3/4
1
2
3
4
2-1/4
2,205
2,415
2,790
3,420
2,375
2,605
3,005
3,680
(51)
(57)
(9.8)
(10.7)
(12.4)
(15.2)
(10.6)
(11.6)
(13.4)
(16.4)
3-1/4
3-1/2
4,250
4,655
5,375
6,585
9,845
10,785
12,450
15,250
(83)
(89)
(18.9)
(20.7)
(23.9)
(29.3)
(43.8)
(48.0)
(55.4)
(67.8)
3-1/8
3-1/2
4,200
4,605
5,315
6,510
9,280
10,165
11,740
14,380
(79)
(89)
(18.7)
(20.5)
(23.6)
(29.0)
(41.3)
(45.2)
(52.2)
(64.0)
20,820
4-3/8
5,860
6,420
7,415
9,080
13,440
14,725
17,000
(102)
(111)
(26.1)
(28.6)
(33.0)
(40.4)
(59.8)
(65.5)
(75.6)
(92.6)
3-3/4
4-1/4
5,665
6,205
7,165
8,775
12,200
13,365
15,430
18,900
(95)
(108)
(25.2)
(27.6)
(31.9)
(39.0)
(54.3)
(59.5)
(68.6)
(84.1)
5-1/2
6,615
7,245
8,365
10,245
18,785
20,575
23,760
29,100
(127)
(140)
(29.4)
(32.2)
(37.2)
(45.6)
(83.6)
(91.5)
(105.7)
(129.4)
Table 21 - Steel design strength for Hilti KWIK Bolt 3 hot-dip galvanized anchors1,2
Nominal anchor
diameter
Nominal
embedment
in. (mm)
Tensile 3 Nsa
lb (kN)
2-1/4
1/2
(57)
3-1/2
Shear 4 Vsa
lb (kN)
2,925
8,745
(38.9)
(89)
(13.0)
3,815
(17.0)
3-1/2
5/8
(89)
4-3/8
13,515
(60.1)
7,565
(33.7)
19,080
(84.9)
11,050
(49.2)
(111)
4-1/4
3/4
(108)
5-1/2
(140)
1
2
3
4
266 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Figure 4
cmin,2
Case 2
cmin,1
Case 1
smin,2
smin,1
spacing s
cmin,1 at smin,1
sdesign
cmin,2 at smin,2
cdesign
Concrete
Edge
edge distance c
3.3.1
Symbol
hef
hmin
Case 1
Case 2
c min,1
for s min,1
cmin,2
for s min,2
Units
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
1/2
2
(51)
4
(102)
3-1/4
(83)
6-1/4
(158)
3-3/4
(95)
3-1/8
(79)
5/8
3-1/4
(83)
6
(152)
2-5/8
(67)
5-1/2
(140)
2-3/4
(70)
2-3/4
(70)
6
(152)
8
(203)
2
(51)
4-7/8
(124)
2-5/8
2-1/4
(67)
(57)
2-3/8
2-1/8
(60)
(54)
3-1/8
(79)
5
(127)
2-1/4
(57)
5-1/4
(133)
3-1/2
(89)
2-1/2
(64)
6
(152)
2
(51)
5
(127)
2-1/2
(64)
2-1/8
(54)
1 Linear interpolation is permitted to establish an edge distance and spacing combination between Case 1 and Case 2.
Linear interpolation for a specific edge .distance c, where cmin,1 < c < cmin,2 will determine the permissible spacings.
3.3.2
3/4
4
(102)
8
(203)
1-78
(48)
4-3/4
(121)
2-1/4
(57)
2-1/8
(54)
3-3/4
(95)
6
8
(152)
(203)
3-1/2
(89)
7-1/2
(191)
6-1/2
(165)
4
(102)
5
(127)
8
(203)
3-5/8
(92)
7-3/8
(187)
4-3/4
(121)
3-7/8
(98)
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 267
Embedment hnom
in.
(mm)
2
(51)
2-3/8
(60)
2-1/2
(64)
3
(76)
3-1/8
(79)
3-1/4
(83)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
> 24
(610)
spacing factor
in tension
AN
2-1/4
(57)
n/a
n/a
n/a
n/a
0.76
0.77
0.79
0.83
0.88
0.92
1.00
1.00
3-1/2
(89)
n/a
0.62
0.63
0.65
0.66
0.67
0.68
0.71
0.73
0.76
0.81
0.86
0.91
0.96
1.00
edge distance
factor in tension
RN
2-1/4
(57)
n/a
n/a
n/a
n/a
n/a
0.67
0.72
0.82
0.92
1.00
3-1/2
(89)
0.38
0.41
0.42
0.46
0.48
0.49
0.51
0.56
0.61
0.67
0.80
0.93
1.00
spacing factor
in shear 3
AV
2-1/4
(57)
n/a
n/a
n/a
n/a
0.64
0.64
0.65
0.68
0.70
0.72
0.76
0.81
0.85
0.89
0.94
0.98
1.00
3-1/2
(89)
n/a
0.54
0.55
0.55
0.56
0.56
0.56
0.57
0.58
0.59
0.61
0.63
0.64
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
0.93
3-1/2
(89)
0.10
0.13
0.14
0.19
0.20
0.21
0.23
0.29
0.34
0.40
0.53
0.66
0.81
0.97
1.00
II to edge
RV
2-1/4
(57)
n/a
n/a
n/a
n/a
n/a
0.79
0.88
1.00
3-1/2
(89)
0.20
0.26
0.28
0.37
0.40
0.42
0.47
0.56
0.61
0.67
0.80
0.93
1.00
Conc. thickness
factor in shear 4
HV
2-1/4
(57)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.84
0.89
0.94
1.00
3-1/2
(89)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.71
0.76
0.81
0.85
0.89
0.93
1.00
Table 24 - Load adjustment factors for 5/8-in. diameter KWIK Bolt 3 hot-dip galvanized anchor in uncracked concrete1,2
5/8-in. KB3
hot-dip galvanized
uncracked concrete
Embedment hnom
in.
(mm)
2
(51)
2-1/8
(54)
2-1/4
(57)
2-1/2
(64)
3
(76)
3-1/2
(89)
4
(102)
4-1/2
(114)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
> 30
(762)
1
2
3
4
Spacing factor
in tension
AN
3-1/2
(89)
n/a
n/a
n/a
0.63
0.66
0.69
0.71
0.74
0.77
0.82
0.87
0.93
0.98
1.00
4-3/8
(111)
n/a
0.59
0.59
0.60
0.63
0.65
0.67
0.69
0.71
0.75
0.79
0.83
0.88
0.92
0.96
1.00
Edge distance
factor in tension
RN
3-1/2
(89)
n/a
n/a
0.38
0.41
0.45
0.50
0.54
0.60
0.66
0.79
0.92
1.00
4-3/8
(111)
0.34
0.34
0.35
0.37
0.40
0.44
0.47
0.51
0.55
0.63
0.74
0.84
0.95
1.00
Spacing factor
in shear 3
AV
3-1/2
(89)
n/a
n/a
n/a
0.55
0.56
0.57
0.58
0.59
0.60
0.62
0.64
0.66
0.68
0.70
0.72
0.74
0.77
0.81
0.85
0.89
0.97
1.00
4-3/8
(111)
n/a
0.53
0.54
0.54
0.55
0.56
0.56
0.57
0.58
0.59
0.61
0.63
0.64
0.66
0.67
0.69
0.72
0.75
0.78
0.82
0.88
0.97
4-3/8
(111)
0.08
0.09
0.10
0.12
0.15
0.19
0.23
0.28
0.33
0.43
0.54
0.66
0.79
0.92
1.00
II to edge
RV
3-1/2
(89)
n/a
n/a
0.27
0.32
0.42
0.50
0.54
0.60
0.66
0.79
0.92
1.00
4-3/8
(111)
0.17
0.18
0.20
0.23
0.30
0.38
0.47
0.51
0.55
0.63
0.74
0.84
0.95
1.00
Conc. thickness
factor in shear 4
HV
3-1/2
(89)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.63
0.69
0.74
0.79
0.84
0.89
0.93
0.97
1.00
4-3/8
(111)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.62
0.67
0.71
0.75
0.80
0.83
0.87
0.94
1.00
268 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Embedment hnom
in.
(mm)
3-1/2
(89)
3-5/8
(92)
3-7/8
(98)
4
(102)
4-1/2
(114)
5
(127)
5-1/2
(140)
6
(152)
7
(178)
8
(203)
9
(229)
10
(254)
11
(279)
12
(305)
14
(356)
16
(406)
18
(457)
20
(508)
24
(610)
30
(762)
> 36
(914)
1
2
3
4
Spacing factor
in tension
AN
4-1/4
(108)
n/a
n/a
n/a
0.68
0.70
0.72
0.74
0.77
0.81
0.86
0.90
0.94
0.99
1.00
5-1/2
(140)
n/a
n/a
0.63
0.63
0.65
0.67
0.68
0.70
0.73
0.77
0.80
0.83
0.87
0.90
0.97
1.00
Edge distance
factor in tension
RN
4-1/4
(108)
0.41
0.42
0.44
0.45
0.49
0.53
0.57
0.62
0.72
0.82
0.92
1.00
5-1/2
(140)
n/a
0.49
0.51
0.52
0.56
0.59
0.63
0.67
0.75
0.84
0.95
1.00
Spacing factor
in shear 3
AV
4-1/4
(108)
n/a
n/a
n/a
0.57
0.58
0.59
0.60
0.60
0.62
0.64
0.66
0.67
0.69
0.71
0.74
0.78
0.81
0.85
0.92
1.00
5-1/2
(140)
n/a
n/a
0.55
0.55
0.56
0.57
0.57
0.58
0.59
0.61
0.62
0.64
0.65
0.66
0.69
0.72
0.74
0.77
0.82
0.91
0.99
5-1/2
(140)
n/a
0.16
0.18
0.18
0.22
0.26
0.30
0.34
0.43
0.52
0.62
0.73
0.84
0.96
1.00
II to edge
RV
4-1/4
(108)
0.41
0.42
0.44
0.45
0.49
0.53
0.57
0.62
0.72
0.82
0.92
1.00
5-1/2
(140)
n/a
0.32
0.35
0.37
0.44
0.52
0.60
0.67
0.75
0.84
0.95
1.00
Conc. thickness
factor in shear 4
HV
4-1/4
(108)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.70
0.75
0.79
0.83
0.87
0.91
0.99
1.00
5-1/2
(140)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.66
0.70
0.74
0.77
0.81
0.87
0.93
0.99
1.00
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 269
1/2
5/8
Effective
embed.
in. (mm)
1-1/2
(38)
2
(51)
2
(51)
3-1/4
(83)
3-1/8
(79)
4
(102)
Nominal
embed.
in. (mm)
1-3/4
(44)
2-3/8
(60)
2-1/4
(57)
3-1/2
(89)
3-1/2
(89)
4-3/8
(111)
2,050
(9.1)
2,050
(9.1)
2,050
(9.1)
3,095
(13.8)
3,575
(15.9)
4,280
(19.0)
4,280
(19.0)
Table 27 - Hilti KWIK Bolt 3 stainless steel design strength in the soffit
of uncracked lightweight concrete over metal deck1,2,3,4,5,7
Nominal
anchor
diameter
1/4
3/8
1/2
5/8
1
2
3
4
5
6
7
Effective
embed.
in. (mm)
1-1/2
(38)
2
(51)
2
(51)
3-1/4
(83)
3-1/8
(79)
4
(102)
Nominal
embed.
in. (mm)
1-3/4
(44)
2-3/8
(60)
2-1/4
(57)
3-1/2
(89)
3-1/2
(89)
4-3/8
(111)
1,460
(6.5)
1,135
(5.0)
1,135
(5.0)
2,880
(12.8)
3,325
(14.8)
3,700
(16.5)
3,700
(16.5)
Nominal embedment
in.
Minimum distance
from edge of block
(mm)
1-1/8
(29)
(51)
1-5/8
(41)
1/4
3/8
2-1/2
(64)
2-1/4
(57)
3-1/2
(89)
2-3/4
(70)
(102)
1/2
5/8
3-1/4
(83)
3/4
4-3/4
(121)
in.
(mm)
(102)
12
(305)
(102)
12
(305)
Shear
lb (kN)
Tension
lb
(kN)
lb
(kN)
150
(0.7)
380
(1.7)
540
(2.4)
445
(2.0)
(3.3)
(102)
320
(1.4)
735
12
(305)
340
(1.5)
940
(4.2)
(102)
1,010
(4.5)
780
(3.5)
12
(305)
1,395
(6.2)
(102)
630
(2.8)
830
(3.7)
12
(305)
665
(3.0)
1,465
(6.5)
905
(4.0)
(102)
12
(305)
1,080
(4.8)
2,375
(10.6)
(102)
815
(3.6)
890
(4.0)
12
(305)
865
(3.8)
2,165
(9.6)
(102)
1,240
(5.5)
970
(4.3)
12
(305)
1,295
(5.8)
2,770
(12.3)
(102)
785
(3.5)
1,035
(4.6)
12
(305)
3,135
(13.8)
(102)
1,645
(7.3)
825
(3.7)
12
(305)
1,710
(7.6)
3,305
(14.7)
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Table 29 - KWIK Bolt 3 carbon steel allowable loads for anchors installed in top of grout-filled concrete masonry walls1,6
Shear
Nominal Anchor
Diameter
Nominal Embedment
Tension
V1
V2
3.3.9
3.3.9
in.
(mm)
lb
(kN)
lb
(kN)
lb
1/2
(76)
645
(2.9)
310
(1.4)
615
(2.7)
(kN)
5/8
3-1/2
(89)
850
(3.8)
310
(1.4)
615
(2.7)
3.3.9
1 All values are for anchors installed in fully grouted concrete masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units may be
lightweight, medium-weight or normal-weight conforming to ASTM C90. Allowable loads are calculated using safety factor of 4.
3.3.9
2 Anchors must be installed a minimum of 1-3/8 inch from any vertical mortar joint (see figure below).
3.3.9
3.3.9
4 Embedment depth is measured from the outside face of the concrete masonry unit.
5 Linear interpolation to determine load values at intermediate edge distances is permitted.
6 All allowable loads based on safety factor of 4.
Grout
V2
V1
Min 1-3/4"
Min 4"
3.3.8.4 Installation
instructions
Installation Instructions For Use (IFU) are
included with each product package.
They can also be viewed or downloaded
online at www.us.hilti.com (US) and
www.hilti.ca (Canada). Because of the
possibility of changes, always verify that
downloaded IFU are current when used.
Proper installation is critical to achieve
full performance. Training is available on
request. Contact Hilti Technical Services
for applications and conditions not
addressed in the IFU.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 271
Size
in.
(mm)
in.
(mm)
1/4 x 1-3/4
1-3/4
(44)
3/4
(18)
1/4 x 2-1/4
2-1/4
(57)
7/8
(22)
1/4 x 3-1/4
3-1/4
(83)
1/4 x 4-1/2
4-1/2
3/8 x 2-1/4
2-1/4
3/8 x 3
(76)
ID
stamp
Box
Carbon steel
304 SS
100
(51)
7/8
(22)
(114)
2-7/8
(75)
(57)
7/8
(22)
1-1/4
(32)
1-1/2
(40)
1-1/4
(32)
3/8 x 3-3/4
3-3/4
(95)
2-1/4
(59)
3/8 x 5
(127)
3-1/2
(91)
50
3/8 x 7
(178)
5-1/2
(142)
2-3/4
(70)
1-1/4
(33)
1/2 x 3-3/4
3-3/4
(95)
1-5/16
(35)
4-1/2
(114)
1/2 x 5-1/2
5-1/2
(140)
1/2 x 7
(178)
5/8 x 3-3/4
3-3/4
(95)
5/8 x 4-3/4
4-3/4
(121)
5/8 x 6
(152)
5/8 x 7
5/8 x 8-1/2
8-1/2
(56)
(35)
2-7/8
(75)
1-5/16
(35)
3-3/4
(96)
4-3/4
(121)
1-1/2
(41)
1-1/2
(41)
2-3/4
(70)
25
(41)
(178)
4-3/4
(121)
(216)
6-1/2
(166)
(180)
1-1/2
(41)
3/4 x 4-3/4
4-3/4
(121)
(140)
2-7/16
(62)
1-1/2
(41)
3-7/16
(85)
1-1/2
(41)
(102)
(254)
10
5-1/2
2-3/16
1-5/16
1-1/2
5/8 x 10
3/4 x 5-1/2
E
G
1/2 x 2-3/4
1/2 x 4-1/2
HDG
D
E
316 SS
15
20
G
10
20
20
(178)
4-5/8
(119)
3/4 x 8
(203)
5-3/4
(146)
3/4 x 10
10
(254)
5-7/8
(152)
3/4 x 12
12
(305)
5-7/8
(152)
3/4 x 7
20
10
1x6
(152)
2-1/4
(57)
1x9
(114)
2-1/4
(57)
1 x 12
12
(114)
(152)
10
272 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
in.
(mm)
Box
Carbon steel
C1/4 x 2
(51)
100
C1/4 x 3
(76)
100
C1/4 x 5
(127)
100
C3/8 x 2-1/4
2-1/4
(57)
100
C3/8 x 3
(76)
100
C3/8 x 4
(102)
50
C3/8 x 5
(127)
50
304 SS
3.3.1
3.3.2
3.3.3
Thread length
Size
in.
(mm)
in.
(mm)
ID stamp
Box
quantity
3/8 x 2-1/4
2-1/4
(57)
7/8
(22)
100
3.3.5
3.3.6
3.3.7
3.3.4
3.3.8
Size
in.
(mm)
Eyelet size
in.
Box quantity
3.3.9
1/4 x 2
2-1/32
(52)
5/16
100
3.3.9
3.3.9
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 273
Notes
274 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Product features
Quick and easy to install.
Length and diameter identification
clearly stamped on head facilitates
quality control and inspection
after installation.
3.3.9.1
Product description
3.3.9.2
Material specifications
3.3.9.2 Material
specifications
Hilti KWIK HUS anchors are manufactured from carbon steel. The anchors are
dull zinc plated to a minimum thickness
of 8 m.
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.8
3.3.8
3.3.8
3.3.8
3.3.8
3.3.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 275
Symbol
Units
3/8
1/2
5/8
3/4
dbit
in.
3/8
1/2
5/8
3/4
dh
in.
1/2
5/8
3/4
7/8
Installation torque
Tinst
ft-lb
40
45
85
115
Timpact
ft-lb
114
450
450
Nominal embedment
hnom
in.
1-5/8
2-1/2
3-1/4
2-1/4
4-1/4
3-1/4
6-1/4
Effective embedment
hef
in.
1.11
1.86
2.20
1.52
2.16
3.22
2.39
3.88
2.92
4.84
ho
in.
1-7/8
2-3/4
3-1/2
2-5/8
3-3/8
4-5/8
3-5/8
5-3/8
4-3/8
6-5/8
cac
in.
2.50
3.12
3.74
2.75
3.70
5.25
3.63
5.81
4.41
7.28
smin,cac
in.
2.25
cmin
in.
1.50
smin
in.
hmin
in.
in.
9/16
3/4
15/16
1-1/8
Ase
in2
0.086
0.161
0.268
0.392
futa
psi
107,120
97,140
90,180
81,600
Wrench size
450
137
450
4
1.75
3
3.25
4.875
3.75
4
4.75
6.75
8.125
1 The data presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D.
2 For installation through the soffit of steel deck into concrete. See figure 3.
3 Tinst applies to installations using a calibrated torque wrench.
4 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above
setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity.
276 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Tension - Nn
Nominal
anchor
diameter
Nominal
embed. 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi 'c = 2500 psi 'c = 3000 psi 'c = 4000 psi 'c = 6000 psi
in. (mm)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
1-5/8
3/8
1/2
5/8
3/4
910
1,000
1,155
1,415
980
1,075
1,245
1,520
(41)
(4.0)
(4.4)
(5.1)
(6.3)
(4.4)
(4.8)
(5.5)
(6.8)
2-1/2
1,980
2,165
2,505
3,065
2,130
2,335
2,695
3,300
(64)
(8.8)
(9.6)
(11.1)
(13.6)
(9.5)
(10.4)
(12.0)
(14.7)
3-1/4
2,545
2,790
3,220
3,945
2,740
3,005
3,465
4,245
(83)
(11.3)
(12.4)
(14.3)
(17.5)
(12.2)
(13.4)
(15.4)
(18.9)
2-1/4
1,460
1,600
1,850
2,265
1,575
1,725
1,990
2,440
(57)
(6.5)
(7.1)
(8.2)
(10.1)
(7.0)
(7.7)
(8.9)
(10.9)
2,475
2,710
3,130
3,835
2,665
2,920
3,375
4,130
(76)
(11.0)
(12.1)
(13.9)
(17.1)
(11.9)
(13.0)
(15.0)
(18.4)
4-1/4
4,505
4,935
5,700
6,980
9,705
10,635
12,280
15,040
3.3.1
3.3.2
3.3.3
3.3.4
(108)
(20.0)
(22.0)
(25.4)
(31.0)
(43.2)
(47.3)
(54.6)
(66.9)
3-1/4
3,240
3,550
4,100
5,025
3,490
3,825
4,415
5,410
(83)
(14.4)
(15.8)
(18.2)
(22.4)
(15.5)
(17.0)
(19.6)
(24.1)
3.3.6
6,705
7,345
8,485
10,390
14,445
15,825
18,270
22,380
(127)
(29.8)
(32.7)
(37.7)
(46.2)
(64.3)
(70.4)
(81.3)
(99.6)
3.3.7
4,380
4,795
5,540
6,785
9,430
10,330
11,930
14,610
3.3.8
(102)
(19.5)
(21.3)
(24.6)
(30.2)
(41.9)
(45.9)
(53.1)
(65.0)
6-1/4
9,345
10,235
11,820
14,475
20,125
22,045
25,455
31,175
3.3.9
(159)
(41.6)
(45.5)
(52.6)
(64.4)
(89.5)
(98.1)
(113.2)
(138.7)
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Apply spacing, edge distance, and concrete thickness factors in tables 4 to 7 as necessary. Compare to steel values in table 3.
The lesser of the values is to be used for the design.
Tabular values are for normal-weight concrete only. For lightweight concrete multiply design strength by a as follows:
for sand-lightweight, a = 0.68; for all-lightweight, a = 0.60
cmin,2
Case 2
cmin,1
Case 1
smin,2
smin,1
Concrete
Edge
3.3.8
3.3.8
3.3.8
3.3.8
3.3.8
spacing s
Figure 2
3.3.5
3.3.8
cmin,1 at smin,1
sdesign
cmin,2 at smin,2
cdesign
edge distance c
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 277
Tensile1
Nsa
lb (kN)
Shear2
Vsa
lb (kN)
5,990
3,095
(26.6)
(13.8)
10,165
4,910
(45.2)
(21.8)
15,735
6,735
(70.0)
(30.0)
20,810
9,995
(92.6)
(44.5)
Table 4 - Load adjustment factors for 3/8-in. diameter KWIK HUS in uncracked concrete1,2
3/8-in. KH
uncracked
concrete
Embedment in.
hnom
(mm)
1-1/2 (38)
2
(51)
2-1/4 (57)
2-1/2 (64)
3
(76)
3-1/4 (83)
3-1/2 (89)
4
(102)
4-1/2 (114)
4-7/8 (124)
5
(127)
6
(152)
7
(178)
8
(203)
9
(229)
10 (254)
11 (279)
12 (305)
14 (356)
16 (406)
18 (457)
20 (508)
24 (610)
1
2
3
4
Spacing factor
in tension
AN
1-5/8
(41)
n/a
n/a
0.84
0.88
0.95
0.99
1.00
Edge distance
factor in tension
RN
Spacing factor
in shear 3
AV
II to edge
RV
Conc. thickness
factor in shear 4
HV
278 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Embedment in.
hnom
(mm)
1-3/4 (44)
2
(51)
2-1/2 (64)
3
(76)
3-1/2 (89)
3-3/4 (95)
4
(102)
4-1/2 (114)
4-3/4 (121)
5
(127)
6
(152)
6-3/4 (171)
7
(178)
8
(203)
9
(229)
10 (254)
11 (279)
12 (305)
14 (356)
16 (406)
18 (457)
20 (508)
> 24 (610)
Spacing factor
in tension
AN
2-1/4
(57)
n/a
n/a
n/a
0.83
0.88
0.91
0.94
0.99
1.00
Edge distance
factor in tension
RN
3
4-1/4 2-1/4
(76) (108) (57)
n/a
n/a 0.68
n/a
n/a 0.75
n/a
n/a 0.91
0.73 0.66 1.00
0.77 0.68
0.79 0.69
0.81 0.71
0.85 0.73
0.87 0.75
0.89 0.76
0.96 0.81
1.00 0.85
0.86
0.91
0.97
1.00
Spacing factor
in shear 3
AV
3
4-1/4 2-1/4
(76) (108) (57)
0.58 0.51 n/a
0.63 0.54 n/a
0.72 0.60 n/a
0.82 0.66 0.67
0.95 0.73 0.69
1.00 0.76 0.71
0.80 0.72
0.87 0.75
0.91 0.76
0.95 0.78
1.00 0.83
0.87
0.89
0.94
1.00
3
4-1/4 2-1/4
(76) (108) (57)
n/a
n/a 0.45
n/a
n/a 0.54
n/a
n/a 0.76
0.62 0.55 1.00
0.64 0.56
0.65 0.57
0.66 0.57
0.68 0.58
0.69 0.59
0.70 0.59
0.75 0.61
0.78 0.62
0.79 0.63
0.83 0.65
0.87 0.66
0.91 0.68
0.95 0.70
0.99 0.72
1.00 0.76
0.79
0.83
0.87
0.94
3
4-1/4 2-1/4
(76) (108) (57)
0.28 0.08 0.68
0.34 0.10 0.75
0.48 0.14 0.91
0.63 0.19 1.00
0.80 0.24
0.89 0.26
0.98 0.29
1.00 0.35
0.38
0.41
0.53
0.64
0.67
0.82
0.98
1.00
Embedment hnom
1
2
3
4
1-3/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
14
16
18
20
24
> 30
Spacing factor
in tension
AN
in.
(mm)
(44)
(51)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
3-1/4
(83)
n/a
n/a
n/a
0.71
0.74
0.78
0.81
0.85
0.88
0.92
0.99
1.00
5
(127)
n/a
n/a
n/a
0.63
0.65
0.67
0.69
0.71
0.74
0.76
0.80
0.84
0.89
0.93
0.97
1.00
Edge distance
factor in tension
RN
3-1/4
(83)
0.62
0.67
0.76
0.86
0.97
1.00
5
(127)
0.51
0.54
0.59
0.65
0.70
0.76
0.83
0.89
0.96
1.00
Spacing factor
in shear 3
AV
3-1/4
(83)
n/a
n/a
n/a
0.61
0.63
0.65
0.66
0.68
0.70
0.72
0.75
0.79
0.83
0.86
0.90
0.94
1.00
5
(127)
n/a
n/a
n/a
0.55
0.55
0.56
0.57
0.58
0.58
0.59
0.61
0.62
0.64
0.65
0.67
0.68
0.71
0.74
0.77
0.80
0.86
0.95
3
4-1/4 2-1/4
3
4-1/4
(76) (108) (57) (76) (108)
0.56 0.17 n/a
n/a
n/a
0.63 0.21 n/a
n/a
n/a
0.72 0.29 n/a
n/a
n/a
0.82 0.38 n/a
n/a
n/a
0.95 0.47 n/a
n/a
n/a
1.00 0.53 0.91 n/a
n/a
0.58 0.94 n/a
n/a
0.69 1.00 n/a
n/a
0.75
0.88 n/a
0.81
0.91 n/a
1.00
0.99 n/a
1.00 0.70
0.72
0.76
0.81
0.85
0.90
0.94
1.00
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.9
1,2
3.3.8
Conc. thickness
factor in shear 4
HV
3.3.8
Table 6 - Load Adjustment Factors for 5/8-in. Diameter KWIK HUS in Uncracked Concrete
5/8-in. KH
uncracked
concrete
II to edge
RV
5
(127)
0.06
0.08
0.11
0.14
0.18
0.22
0.26
0.30
0.35
0.40
0.50
0.61
0.73
0.86
0.99
1.00
II to edge
RV
3-1/4
(83)
0.47
0.57
0.76
0.86
0.97
1.00
5
(127)
0.13
0.15
0.21
0.28
0.35
0.43
0.52
0.60
0.70
0.80
1.00
Conc. thickness
factor in shear 4
HV
3-1/4
(83)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.85
0.89
0.93
1.00
5
(127)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.69
0.74
0.78
0.81
0.85
0.92
0.98
1.00
3.3.8
3.3.8
3.3.8
3.3.8
3.3.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 279
Embedment hnom
1
2
3
4
1-3/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
8-1/8
9
10
11
12
14
16
18
20
24
30
> 36
in.
(mm)
(44)
(51)
(64)
(76)
(89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(206)
(229)
(254)
(279)
(305)
(356)
(406)
(457)
(508)
(610)
(762)
(914)
Spacing factor
in tension
AN
4
(102)
n/a
n/a
n/a
n/a
n/a
0.73
0.76
0.79
0.81
0.84
0.90
0.96
0.96
1.00
6-1/4
(159)
n/a
n/a
n/a
n/a
n/a
0.64
0.65
0.67
0.69
0.71
0.74
0.78
0.78
0.81
0.84
0.88
0.91
0.98
1.00
Edge distance
factor in tension
RN
4
(102)
0.57
0.61
0.68
0.76
0.84
0.93
1.00
6-1/4
(159)
0.48
0.50
0.54
0.58
0.62
0.67
0.72
0.76
0.81
0.86
0.97
1.00
Spacing factor
in shear 3
AV
4
(102)
n/a
n/a
n/a
n/a
n/a
0.58
0.59
0.60
0.61
0.62
0.64
0.66
0.66
0.68
0.70
0.72
0.74
0.78
0.82
0.86
0.90
0.98
1.00
6-1/4
(159)
n/a
n/a
n/a
n/a
n/a
0.55
0.56
0.56
0.57
0.58
0.59
0.60
0.60
0.62
0.63
0.64
0.65
0.68
0.71
0.73
0.76
0.81
0.89
0.96
6-1/4
(159)
0.05
0.06
0.08
0.11
0.14
0.17
0.20
0.24
0.28
0.31
0.40
0.48
0.50
0.58
0.68
0.78
0.89
1.00
II to edge
RV
4
(102)
0.19
0.23
0.33
0.43
0.54
0.66
0.79
0.92
1.00
6-1/4
(159)
0.10
0.12
0.17
0.22
0.28
0.34
0.41
0.48
0.55
0.63
0.79
0.97
0.99
1.00
Conc. thickness
factor in shear 4
HV
4
(102)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.69
0.75
0.80
0.80
0.85
0.89
0.94
0.98
1.00
6-1/4
(159)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.65
0.68
0.72
0.75
0.79
0.85
0.91
0.96
1.00
Figure 3 Installation of KWIK HUS (KH) in soffit of concrete over steel deck floor and roof assemblies1
1 A
nchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is
satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset
distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge
distance is also satisfied.
280 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3/8
1/2
5/8
3/4
Shear - Vn
Tension - Nn
Tension - Nn
1-5/8
835
965
1,000
1,000
660
760
2,360
(41)
(3.7)
(4.3)
(4.4)
(4.4)
(2.9)
(3.4)
(10.5)
(10.5)
2-1/2
1,455
1,680
905
905
1,900
2,195
3,655
3,655
2,360
(8.5)
(9.8)
(16.3)
(16.3)
n/a
n/a
n/a
n/a
3.3.1
3.3.2
(64)
(6.5)
(7.5)
(4.0)
(4.0)
3-1/4
2,550
2,945
2,165
2,165
(83)
(11.3)
(13.1)
(9.6)
(9.6)
2-1/4
850
980
965
965
905
1,045
4,710
4,710
(4.0)
(4.6)
(21.0)
(21.0)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
3.3.8
n/a
n/a
n/a
n/a
3.3.9
(57)
(3.8)
(4.4)
(4.3)
(4.3)
1,990
2,300
1,750
1,750
(76)
(8.9)
(10.2)
(7.8)
(7.8)
4-1/4
3,485
4,025
2,155
2,155
(108)
(15.5)
(17.9)
(9.6)
(9.6)
3-1/4
2,715
3,135
2,080
2,080
(83)
(12.1)
(13.9)
(9.3)
(9.3)
6,170
7,125
2,515
2,515
(127)
(27.4)
(31.7)
(11.2)
(11.2)
2,715
3,135
2,255
2,255
(102)
(12.1)
(13.9)
(10.0)
(10.0)
Linear interpolation between embedment depths and concrete compressive strengths is not permitted.
Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x hnom (nominal embedment).
Shear - Vn
Nominal
embed. 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi 'c = 3000 psi 'c = 4000 psi
in. (mm)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
lb (kN)
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.8
Tabular values are lightweight concrete and no additional reduction factor is needed.
3.3.8
3.3.8
3.3.8
3.3.8
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 281
Edge distance
Nominal
embedment 3
in.
Loads at
ccr and scr
Critical - scr6
in.
Minimum - smin6
in.
Load
reduction
factor at smin6
1 5/8
2 1/2
3 1/4
2 1/4
3
4 1/4
3 1/4
5
4
6 1/4
535
895
1,210
710
1,110
1,515
1,155
1,735
1,680
2,035
0.70
0.80
10
12
3/8
1/2
5/8
3/4
Critical - ccr7
in.
Minimum cmin8
in.
Load reduction
factor 7
1.00
0.60
1.00
0.60
10
1.00
0.60
12
1.00
Table 10 Allowable shear loads for KWIK HUS installed in grout-filled masonry walls (lb)1,2,3,4,5
Spacing
Edge distance
Load reduction factor at cmin
Nominal
anchor
diameter
3/8
1/2
5/8
3/4
Nominal
embedment 3
in.
Loads at
ccr and scr
1 5/8
2 1/2
3 1/4
2 1/4
3
4 1/4
3 1/4
5
4
6 1/4
1,140
1,165
1,190
1,845
2,055
2,745
3,040
3,485
3,040
3,485
Critical - scr6
in.
Minimum - smin6
in.
Load
reduction
factor at smin7
0.94
0.88
10
0.36
10
10
0.36
12
Critical - ccr8
in.
Minimum cmin8
in.
1.00
1.00
1.00
1.00
0.94
0.89
0.82
0.92
0.82
0.92
1 All values are for anchors installed in fully-grouted masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units shall
be lightweight or normal-weight.
2 Anchors may not be installed within 1 inch in any direction of a vertical joint.
3 Embedment depth is measured from the outside face of the concrete masonry embedment.
4 Linear interpolation of load values between minimum spacing (smin) and critical spacing (scr) and between minimum edge distance (cmin) and
critical edge distance (ccr) is permitted.
( )( )
282 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Nominal
embedment
in.
Minimum
edge distance
in.
Minimum
spacing
in.
Minimum
end distance
in.
Perpendicular to
edge of masonry
wall
1/2
4 1/4
1 3/4
680
305
1,110
5/8
1 3/4
10
1,310
305
1,165
Tension
Parallel to
edge of masonry
wall
1 All values are for anchors installed in fully-grouted masonry with minimum masonry prism strength of 1,500 psi. Concrete masonry units shall
be lightweight or normal-weight.
( )( )
3.3.1
3.3.2
3.3.3
3.3.6
3.3.4
3.3.5
3.3.7
3.3.8
3.3.9
3.3.8
3.3.8
3.3.8
3.3.8
Hole diameter
Anchor length
See figure 1
KH 3/8 x 2-1/8
3/8
2-1/8
KH 3/8 x 3
3/8
KH 3/8 x 3-1/2
3/8
3-1/2
2-1/2
50
KH 3/8 x 4
3/8
3-1/4
50
Description
Minimum
embedment depth
Qty / Box
3.3.8
1-5/8
50
2-1/2
50
3.3.8
KH 3/8 x 5
3/8
3-1/4
30
KH 1/2 x 3
1/2
2-1/4
30
KH 1/2 x 3-1/2
1/2
3-1/2
25
25
KH 1/2 x 4
1/2
KH 1/2 x 4-1/2
1/2
4-1/2
4- 1/4
25
KH 1/2 x 5
1/2
4-1/4
25
KH 1/2 x 6
1/2
4-1/4
25
KH 5/8 x 4
5/8
3-1/4
15
KH 5/8 x 5-1/2
5/8
5-1/2
3-1/4
15
KH 5/8 x 6-1/2
5/8
6-1/2
3-1/4
15
KH 3/4 x 4-1/2
3/4
4-1/2
10
KH 3/4 x 5-1/2
3/4
5-1/2
10
KH 3/4 x 7
3/4
10
KH 3/4 x 9
3/4
10
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 283
Product features
HCA hex bolt may be reused
four times providing major cost
savings. A new coil is required for
each reuse.
Bolt type anchor enables low
profile fastenings
Preassembled units allow quick
production fastening
Utilizes a disposable, low cost
expansion coil which minimizes
reuse costs
Heat treated to Grade 5
specification, which provides
high shear load capacity
Symbol Units
1/4
do
in.
1/4
3/8
1/2
5/8
3/4
Embedment mark1
hs
in.
3/8
5/8
5/8
3/4
min.
Anchor Length
max.
in.
in.
1-3/4 2-1/4
3-1/2
5
dh
in.
5/16
Installation torque
Tinst
ft-lb
10
Minimum base
material thickness
in.
3
7
3-1/2 4-1/2
8
10
7/16
9/16
11/16 13/16
40
80
130
180
( )( )
284 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Nominal
embedment
in.
3/4
1
1-1/2
2
2
3
2-3/8
3-7/8
3-1/4
4-1/2
Shear
230
380
850
1,390
1,515
3,020
2,175
5,000
3,915
6,810
Tension3
325
500
920
1,420
1,420
2,605
1,835
3,825
2,940
4,790
Shear
330
535
1,205
1,965
2,145
4,270
3,075
7,070
5,540
9,630
Shear
400
655
1,475
2,410
2,625
5,230
3,765
8,660
6,780
11,705
Tension
Shear
1,620
835
4,375
2,255
7,775
4,005
12,150
6,260
17,495
9,010
3.3.4
1/4
3/8
1/2
5/8
3/4
Nominal
embedment
in.
3/4
1
1-1/2
2
2
3
2-3/8
3-7/8
3-1/4
4-1/2
Shear
930
1,515
3,410
5,565
6,065
12,080
8,700
19,995
15,660
27,235
3.3.2
3.3.3
3 Reduce tension capacity by 20% for HCA Hex Head Bolts that are reused. Coils may not be reused.
Nominal
anchor
diameter
in.
3.3.1
Shear
1,315
2,145
4,825
7,865
8,575
17,085
12,305
28,275
22,150
38,515
Shear
1,610
2,625
5,910
9,635
10,505
20,930
15,070
34,630
27,125
47,170
Tension
Shear
4,910
2,945
13,255
7,950
23,560
14,135
36,815
22,090
53,015
31,810
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.10
3.3.9
1 Steel strength calculated using futa Anominal for tension and 0.6 futa Anominal for shear.
2 Reduce tension capacity by 20% for HCA Hex Head Bolts that are reused. Coils may not be reused.
3.3.9
Load Direction
Critical
Minimum
Influence factor3
Tension
3.0 hnom
1.0 hnom
AN = 0.70
Shear
2.0 hnom
1.0 hnom
AV = 0.70
Tension
1.5 hnom
0.8 hnom
RN = 0.75
Shear
toward edge4
2.5 hnom
1.0 hnom
RV1 = 0.25
Shear
II or away from edge4
2.5 hnom
1.0 hnom
RV2 = 0.50
1 For edge and spacing distances between critical and minimum spacing/edge distances, use linear
interpolation.
3.3.9
concrete free
edge
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 285
Fixture thickness at
minimum embedment
Box / qty
1/4
5/8
100
HCT 1/4
100
1/4
1-3/8
100
HCT 3/8
100
1/4
2-3/8
100
HCT 1/2
100
3/8
1/8
100
HCT 5/8
100
HCA 3/8 X 3
3/8
7/8
100
HCT 3/4
50
HCA 3/8 X 5
3/8
2-7/8
50
HCA 1/2 X 3
1/2
3/8
50
HCA 1/2 X 4
1/2
1-3/8
25
1/2
2-7/8
25
HCA 1/2 X 7
1/2
4-3/8
25
5/8
3/8
25
HCA 5/8 X 5
5/8
1-7/8
25
HCA 5/8 X 8
5/8
4-7/8
20
3/4
1/4
20
HCA 3/4 X 6
3/4
1-3/4
10
HCA 3/4 X 10
3/4
5-3/4
10
Description
1
2
Description
Box qty.
286 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
HDI stainless steel anchors are manufactured from AISI Type 303 stainless steel.
Insert thread
Nominal bit diameter
d
dbit
UNC
in.
Nominal embedment
Anchor length
Hole depth
hnom
th
Installation torque
Tinst
ho
3.3.2
3.3.3
3.3.4
3.3.5
Listings/Approvals
HDI+, HDI-L+ and HDI anchors are manufactured from mild carbon steel. Anchor
bodies are zinc plated in accordance with ASTM B633, SC 1, Type III.
Symbol
3.3.1
3.3.6
Guide specifications
Setting Information
HDI
FM (Factory Mutual)
Pipe Hanger Components for Automatic
Sprinkler Systems HDI+ 3/8, HDI-L+ 3/8,
HDI+1/2, HDI-L+ 1/2, HDI 5/8
and HDI 3/4
UL LLC
UL 203 Pipe Hanger Equipment for Fire
Protection Services HDI+ 3/8, HDI-L+
3/8, HDI+1/2, HDI-L+ 1/2, HDI 5/8
and HDI 3/4
3.3.7
3.3.8
3.3.9
3.3.9
3.3.11
3.3.9
5/8
5/8-11
27/32
3/4
3/4-10
1
3.3.9
3.3.9
in.
(mm)
1
(25)
1-9/16
(40)
2
(51)
2-9/16
(65)
3-3/16
(81)
in.
(mm)
ft-lb
(Nm)
in.
(mm)
7/16
(11)
4
(5)
3
(76)
5/8
(15)
11
(15)
3-1/8
(79)
11/16
(17)
22
(30)
4
(102)
7/8
(22)
37
(50)
5-1/8
(130)
1-3/8
(34)
80
(109)
6-3/8
(162)
3.3.9
HDI+ and HDI-L+ are available in 1/4-, 3/8- and 1/2-in. The HDI is available in 5/8- and 3/4-in.
( ) ( )
Nd
N rec
5/3
Vd
Vrec
5/3
1.0
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 287
'c = 2,000
'c = 4,000
'c = 6,000
Tension
Shear
Tension
Shear
Tension
Shear
1/4
3/8
1/2
5/8
3/4
500
635
945
1,875
2,500
450
965
1,500
2,500
3,875
570
920
1,605
2,920
4,065
625
1,250
1,940
3,250
5,000
790
1,260
1,950
3,715
5,565
700
1,500
2,500
3,750
5,500
Table 3 - HDI+, HDI-L+ and HDI carbon steel ultimate loads in concrete (lb)1
Nominal
anchor
diameter
in.
'c = 2,000
'c = 4,000
'c = 6,000
Tension
Shear
Tension
Shear
Tension
Shear
1/4
3/8
1/2
5/8
3/4
1,995
2,540
3,780
7,500
10,000
1,800
3,850
6,000
1,000
15,500
2,270
3,685
6,425
11,685
16,260
2,500
5,000
8,500
13,000
20,000
3,150
5,035
7,810
14,865
22,250
2,800
6,000
10,000
15,000
22,000
1 The shear tests were conducted with SAE Grade 5 bolts with minimum yield strength of 85 ksi and minimum tension strength of 120 ksi. Shear testing for the 1/4-in.
models were conducted with SAE Grade 8 bolts with minimum yield strength of 120 ksi and minimum tension strength of 150 ksi in 6,000 psi concrete. High-strength
bolts were used to force concrete failure modes. When using steel bolts with a lower tensile strength, steel failure must be considered.
2 Allowable loads calculated with a factor of safety of 4.
Table 4 - HDI+, HDI-L+ and HDI carbon steel allowable loads in lightweight concrete
and lightweight concrete poured over metal deck (lb)1,2,3,4
Lightweight concrete poured over metal deck
Nominal
anchor
diameter
in.
Tension
Shear
Tension
Shear
Tension
Shear
1/4
3/8
1/2
5/8
3/4
465
720
1,035
1,465
2,075
340
940
1,700
2,835
3,680
530
810
1,035
335
1,010
1,755
375
500
625
875
1,250
250
500
750
875
1,000
Lightweight concrete
Upper flute
Lower flute
1 The shear tests were conducted with SAE Grade 5 bolts with minimum yield strength of 85 ksi and minimum tension strength of 120 ksi. Shear testing for the 1/4-in.
models were conducted with SAE Grade 8 bolts with minimum yield strength of 120 ksi and minimum tension strength of 150 ksi in 6,000 psi concrete. High-strength
bolts were used to force concrete failure modes. When using steel bolts with a lower tensile strength, steel failure must be considered.
2 Minimum compressive strength of structural lightweight concrete is 3,000 psi.
3 See figure 1 for typical details.
4 Allowable loads calculated with a factor of safety of 4.
Tension
Shear
Tension
Shear
1/4
3/8
1/2
5/8
3/4
480
1,040
1,840
2,630
3,830
600
1,230
2,760
4,510
5,580
740
1,460
2,410
3,770
5,030
600
1,230
2,760
4,510
5,580
'c = 4,000
'c = 6,000
Tension
Shear
Tension
Shear
1/4
3/8
1/2
5/8
3/4
1,930
4,170
7,350
10,540
15,340
2,400
4,920
11,040
18,040
22,320
2,950
5,850
9,630
15,100
20,130
2,400
4,920
11,040
18,040
22,320
'c = 4,000
'c = 6,000
= Actual Spacing
hnom
3.3.3
(mm)
in.
(mm)
1/4
(6.4)
( 25)
3/8
(9.5)
1-9/16
(40)
1/2
(12.7)
( 51)
5/8
(15.8)
2-9/16
( 65)
3.3.6
3/4
(19.1)
3-3/16
( 81)
3.3.7
in.
(mm)
1/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
7
8
9
10
11
12
( 51)
( 64)
( 76)
( 89)
(102)
(114)
(127)
(140)
(152)
(178)
(203)
(229)
(254)
(279)
(305)
.50
.67
.83
1.0
3/8
.50
.58
.69
.79
.90
1.0
Tension RN
Anchor diameter
A = 0.33
1/2
.50
.58
.67
.75
.83
1.0
5/8
.50
.55
.61
.74
.87
1.0
s cr = 3.5 h nom
s
0.17
h nom
for s cr > s > s min
Edge distance c
3/4
.50
.57
.67
.77
.88
.98
1.0
in.
(mm)
1/4
2
2-1/2
3
3-1/2
4
4-1/2
5
5-1/2
6
6-1/2
7
8
9
10
( 51)
( 64)
( 76)
( 89)
(102)
(114)
(127)
(140)
(152)
(165)
(178)
(203)
(229)
(254)
.80
.90
1.0
3/8
.80
.85
.91
.98
1.0
Shear RV
Anchor diameter
RN = 0.2
1/2
5/8
1/4
.65
.83
1.0
.80
.85
.90
.95
1.0
c
+ 0.4
h nom
for ccr > c > cmin
.80
.83
.87
.91
.95
1.0
.80
.84
.90
.96
1.0
3/8
.65
.73
.85
.96
1.0
3.3.5
3.3.8
3.3.9
Anchor diameter
3/4
3.3.4
3.3.9
Tension/shear loads
Spacing s
3.3.2
in.
3.3.1
1/2
5/8
3/4
3.3.11
3.3.9
.65
.74
.83
.91
1.0
3.3.9
.65
.70
.77
.84
.91
1.0
3.3.9
.65
.72
.83
.94
1.0
3.3.9
c cr = 3.0 h nom
c
RV = 0.35
0.05
h nom
for c cr > c > c min
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 289
Description
Qty / box
HDI+ 1/4
HDI-L+ 1/4
1/4
100
HDI+ 3/8
HDI-L+ 3/8
3/8
50
HDI+ 1/2
HDI-L+ 1/2
1/2
50
HDI 5/8
5/8
25
HDI 3/4
3/4
25
HDI-SS anchors
Stainless steel
Anchor thread size
Qty / box
Description
1/4
100
3/8
50
1/2
50
5/8
25
3/4
25
5/8
3/4
Description
HST 1/4 Setting tool
1/4
3/8
1/2
290 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Guide specifications
Expansion anchor shall be flush or
shell type and zinc plated in accordance
with ASTM B633, SC 1, Type III.
Anchors shall be Hilti HDI-P anchors as
supplied by Hilti.
3.3.1
3.3.2
3.3.3
3.3.4
Listings/Approvals
FM (Factory Mutual) for 3/8-in. model
3.3.8
Length
in. (mm)
Nom.
bit
dia.
in.
Hollow core1,2
Shear
3.3.9
3
Tension
Shear
Tension
Shear
3.3.9
Hollow core1,2
Tension
Shear
1/4
5/8
(15.9)
3/8
1,430
(6.4)
1,870
(8.3)
1,550
(6.9)
2,275
(10.1)
285
(1.3)
375
(1.7)
310
(1.4)
455
(2.0)
3/8
3/4
(19.1)
1/2
1,900
(8.5)
3,000
(13.3)
2,100
(9.3)
4,000
(17.8)
380
(1.7)
600
(2.7)
420
(1.9)
800
(3.6)
1/2
(25.4)
5/8
3,000
(13.3)
6,075
(27.0)
3,110
(13.8)
5,495
(24.5)
600
(2.7)
1215
(5.4)
620
(2.8)
1,100
(4.9)
1 The Admissible Anchor Location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of
the cable with the hollow core plank supplier to confirm Admissible Anchor Location.
2 Minimum compressive strength of hollow core panels is 7,000 psi at the time of installation. The minimum thickness t is 1 3/8 inches.
3 Allowable loads calculated with a 5:1 factor-of-safety.
3.3.9
3.3.12
3.3.9
3.3.9
3.3.9
Installation Instructions For Use (IFU) are included with each product
package. They can also be viewed or downloaded online at www.
us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility
of changes, always verify that downloaded IFU are current when
used. Proper installation is critical to achieve full performance.
Training is available on request. Contact Hilti Technical Services for
applications and conditions not addressed in the IFU.
3.3.6
3.3.7
Nominal
anchor
diameter
3.3.5
Bit diameter
Qty / box
HDI-P 1/4
3/8
100
HDI-P 3/8
1/2
100
HDI-P 1/2
5/8
50
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 291
Product features
HCI-WF
HCI-MD
Listings/Approvals
FM (Factory Mutual)
Pipe Hanger Components for Automatic
Sprinkler Systems 3/8 through 3/4
UL LLC
UL 203 Pipe Hanger Equipment for Fire
Protection Services 3/8 through 3/4
Guide specifications
HCI-WF: Concrete anchor shall be
carbon steel, cast-in type with single
internal thread and a zinc/yellow
chromate plating and contained by a
plastic flange. Anchor shall have breakoff nails for attachment to the surface
of wood forms. Anchor will bear the
diameter and manufacturer name on
its hexagon head. Anchors shall be
HCI-WF as supplied by Hilti.
HCI-MD: Concrete anchor shall be
carbon steel, cast-in type with single
internal thread and a zinc/yellow
chromate plating. Anchor shall have a
protective plastic sleeve, steel flange
with predrilled additional fastening holes
and placement spring for attachment
to metal deck, anchor is to be secured
by clamping the deck between the
steel flange and the protective plastic
sleeve. Anchor shall bear the diameter
and manufacturer name on its hexagon
head. Anchors shall be HCI-MD as
supplied by Hilti.
292 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
HCI-WF
HCI-MD
Insert body
Flange
Engineered plastic
Spring
N/A
Plating
Protective sleeve
N/A
Engineered plastic
Symbol
Units
d
dbit
UNC
in.
hs
th
Sleeve length
sl
Length
tsh
tsf
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
3.3.1
1-7/8
(48)
1/2
(13)
3-3/8
(86)
5-7/16
(138)
1/8
(3.2)
5/64
(2.0)
1-7/8
(48)
5/8
(16)
3-3/8
(86)
5-7/16
(138)
1/8
(3.2)
5/64
(2.0)
3.3.2
3.3.3
1-7/8
(48)
3/4
(20)
3-3/8
(86)
5-7/16
(138)
1/8
(3.2)
5/64
(2.0)
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Figure 1 HCI-MD specifications
See Figure 3
3.3.9
3.3.9
Symbol
Units
Insert thread
th
dpf
tpf
Length
tsh
UNC
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
1/4
1/4-20
1/4
6
1-1/2
(38)
7/64
(2.8)
2
(51)
1/8
(3.2)
7/8
(22)
4
(102)
3/4
3/4-10
3/4
20
1-1/2
(38)
7/64
(2.8)
2-3/16
(57)
1/8
(3.2)
7/8
(22)
4
(102)
3.3.9
3.3.13
3.3.9
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 293
( ) ( )
Nd
5/3
N rec
Vd
5/3
Vrec
1.0
Table 3 - HCI-MD ultimate loads in the soffit of 3,000 psi sand lightweight concrete over metal deck1,2,3
Nominal
anchor
diameter
3/8
1/2
5/8
3/4
1
2
3
4
Embedment
in. (mm)
Minimum
spacing
in. (mm)
Minimum
edge
distance4
in. (mm)
Tension
lb (kN)
Shear
lb (kN)
Tension
lb (kN)
2
(51)
2
(51)
2
(51)
2
(51)
9
(229)
9
(229)
9
(229)
9
(229)
12
(305)
12
(305)
12
(305)
12
(305)
6,250
(27.8)
9,485
(42.2)
9,485
(42.2)
11,195
(49.8)
6,940
(30.9)
11,010
(49.0)
11,010
( 49.0)
11,010
(49.0)
3,280
(14.6)
4,710
(21.0)
4,710
(21.0)
5,010
(22.3)
Shear
lb (kN)
II to flute
4,660
(20.7)
4,660
(20.7)
4,660
(20.7)
4,660
(20.7)
to flute
3,825
(17.0)
3,825
(17.0)
3,825
(17.0)
3,825
(17.0)
Embedment
in. (mm)
Minimum
insert
spacing
in. (mm)
Minimum
insert edge
distance
in. (mm)
Tension
lb (kN)
Shear
lb (kN)
1-7/8
(48)
1-7/8
(48)
2
(51)
2
(51)
2
(51)
9
(229)
9
(229)
9
(229)
9
(229)
9
(229)
6
(152)
6
(152)
6
(152)
6
(152)
6
(152)
6,000
(26.7)
6,000
(26.7)
6,000
(26.7)
6,000
(26.7)
6,000
(26.7)
4,945
(22.0)
4,945
(22.0)
8,830
(39.3)
8,830
(39.3)
10,510
(46.8)
Nominal
anchor
diameter
UL max pipe
size (in.)
UL test
load (lb)
3/8
1/2
5/8
3/4
4
8
12
12
1,500
4,050
7,900
7,900
Lower flute
FM max pipe UL max pipe
size (in.)
size (in.)
4
8
12
12
4
8
UL test
load (lb)
1,500
4,050
HCI-WF
FM max pipe UL max pipe
size (in.)
size (in.)
4
8
4
8
8
8
UL test
load (lb)
FM max pipe
size (in.)
1,500
4,050
4,050
4,050
4
8
294 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
Description
Sleeve
color2
Qty / box
3.3.9
3.3.9
HCI WF 1/4
Green
150
HCI WF 3/8
Red
150
100
HCI WF 1/2
Orange
HCI WF 5/8
Yellow
100
HCI WF 3/4
Black
100
3.3.9
3.3.13
3.3.9
Sleeve
color2
Qty / box
HCI MD 1/4
Green
100
7/8
HCI MD 3/8
Red
100
7/8
HCI MD 1/2
Orange
60
1-3/16
HCI MD 5/8
Yellow
60
1-3/16
HCI MD 3/4
Black
60
1-1/4
3.3.9
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 295
Setting information
Symbol
Thread size
1/4
UNC
in.
dbit
in.
1/4
5/16
3/8
Minimum nominal
embedment
hnom
in.
(mm)
in.
(mm)
ft-lb
(Nm)
ft-lb
(Nm)
1
(25)
1-3/8
(35)
1
(25)
1-3/8
(35)
12
(16)
5
(7)
1-1/4
(32)
1-3/4
(45)
18
(24)
10
(14)
Installation torque
ho
Tinst1
Tinst2
2
(3)
3/4
1/2-13
5/8-11
1/2
5/8
3/4
1 1/2
(38)
2-1/8
(54)
35
(47)
15
((20)
2
(51)
2-5/8
(67)
2
(51)
2-5/8
(67)
60
(81)
90
(122)
( ) ( )
Nd
N rec
5/3
Vd
Vrec
5/3
1.0
296 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Bolt
diameter
in.
1/4
5/16
3/8
1/2
5/8
3/4
3/16
1/4
5/16
3/8
1/2
5/8
Nominal
embedment
in. (mm)
1
1
1-1/4
1-1/2
2
2
(25)
(25)
(32)
(38)
(51)
(51)
Tension
lb
(kN)
225
350
450
675
1,035
1,125
Shear 2
lb
(kN)
(1.0)
(1.5)
(2.0)
(3.0)
(4.6)
(5.0)
305
560
870
1,250
1,750
1,750
(1.4)
(2.5)
(3.9)
(5.6)
(7.8)
(7.8)
Tension
lb
(kN)
250
450
565
925
1,500
1,500
Shear 2
lb
(kN)
(1.1)
(2.0)
(2.5)
(4.1)
(6.7)
(6.7)
305
560
870
1,325
2,295
3,000
Tension
lb
(kN)
(1.4)
(2.5)
(3.9)
(5.9)
(10.2)
(13.3)
250
500
700
1,100
1,950
1,950
(1.1)
(2.2)
(3.1)
(4.9)
(8.7)
(8.7)
Shear 2
lb
(kN)
305
560
890
1,325
2,295
3,010
(1.4)
(2.5)
(4.4)
(5.9)
(10.2)
(13.4)
3.3.2
Nominal
embedment
in.
(mm)
1-1/8
1-1/4
1-1/2
Tension
lb
(kN)
(29)
(32)
(38)
235
310
450
(1.0)
(1.4)
(2.0)
Shear
lb
(kN)
450
675
1,000
(2.0)
(3.0)
(4.4)
Tension
lb
(kN)
300
410
600
(1.3)
(1.8)
(2.7)
Shear
lb
(kN)
450
675
1,000
(2.0)
(3.0)
(4.4)
3.3.3
Tension
lb
(kN)
3.3.4
200
335
470
(0.9)
(1.5)
(2.1)
Shear
lb
(kN)
400
600
890
(1.8)
(2.7)
(4.0)
1/4
(25)
5/16
(25)
3/8
1-1/4 (32)
1/2
1-1/2 (38)
5/8
(51)
3/4
(51)
Edge
distance
in. (mm)
4
12
4
12
4
12
4
12
4
12
4
12
(101)
(305)
(101)
(305)
(101)
(305)
(101)
(305)
(101)
(305)
(101)
(305)
3.3.5
3.3.6
3.3.7
Nominal
anchor
diameter
3.3.1
Tension
lb (kN)
Shear
lb (kN)
290 (1.3)
305 (1.4)
385 (1.7)
500 (2.2)
435 (1.9)
725 (3.2)
605 (2.7)
710 (3.2)
840 (3.7)
865
1,145
1,050
1,815
1,050
1,970
(3.8)
(5.1)
(4.7)
(8.1)
(4.7)
(8.8)
Nominal
Anchor
Diameter
1/4
5/16
3/8
1/2
Nominal
embedment
in.
(mm)
1
1
1-1/4
1-1/2
(25)
(25)
(32)
(38)
Tension
lb
(kN)
350
375
435
565
(1.5)
(1.7)
(1.9)
(2.5)
Shear
lb
(kN)
305
560
800
1,125
(1.4)
(2.5)
(3.5)
(5.0)
1/4
5/16
3/8
1/2
Nominal
embedment
in.
(mm)
1
1
1-1/4
1-1/2
(25)
(25)
(32)
(38)
Tension
lb
(kN)
350
345
375
435
3.3.9
3.3.9
3.3.9
3.3.9
Nominal
Anchor
Diameter
3.3.8
(1.5)
(1.5)
(1.7)
(1.9)
lb
Shear
(kN)
305
530
850
1,230
3.3.9
3.3.14
3.3.9
(1.4)
(2.3)
(3.8)
(5.5)
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 297
Bolt thread
Minimum
embedment
Fastens
materials up to
Qty / box
1/4
3/16-24
1/4
100
HLC-RS 1/4 x 2
1/4
3/16-24
100
HLC-RS 1/4 x 4
1/4
3/16-24
100
Description
Bolt thread
Minimum
embedment
Fastens
materials up to
Qty / box
5/16
1/4-20
5/8
100
5/16
1/4-20
1-5/8
100
3/8
5/16-18
1-1/4
5/8
50
HLC-H 3/8 x 3
3/8
5/16-18
1-1/4
1-3/4
50
1/2
3/8-16
1-1/2
3/4
50
HLC-H 1/2 x 3
1/2
3/8-16
1-1/2
1-1/2
25
HLC-H 1/2 x 4
1/2
3/8-16
1-1/2
2-1/2
25
Description
A
Flat phillips head (FPH)
Nominal
bit diameter
Bolt thread
Minimum
embedment
Fastens
materials up to
Qty / box
1/4
3/16-24
3/8
100
HLC-FPH 1/4 x 2
1/4
3/16-24
100
HLC-FPH 1/4 x 3
1/4
3/16-24
100
HLC-FPH 1/4 x 4
1/4
3/16-24
100
3/8
5/16-18
1-1/4
1-1/2
50
HLC-FPH 3/8 x 4
3/8
5/16-18
1-1/4
2-3/4
50
HLC-FPH 3/8 x 5
3/8
5/16-18
1-1/4
3-3/4
25
HLC-FPH 3/8 x 6
3/8
5/16-18
1-1/4
4-3/4
25
Description
Definition of nomenclature
Outside diameter of sleeve, see tables
for threaded bolt diameter
298 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Description
Bolt thread
Minimum
embedment
Fastens
materials up to
Qty / box
5/16
1/4-20
1/2
100
5/16
1/4-20
1 -1/2
100
3/8
5/16-18
1-1/4
5/8
50
HLC-HX 3/8 x 3
3/8
5/16-18
1-1/4
1-3/4
50
1/2
3/8-16
1-1/2
3/4
25
HLC-HX 1/2 x 3
1/2
3/8-16
1-1/2
1-1/2
25
HLC-HX 1/2 x 4
1/2
3/8-16
1-1/2
2-1/2
25
HLC-HX 1/2 x 6
1/2
3/8-16
1-1/2
4-1/2
15
5/8
1/2-13
1/4
25
5/8
1/2-13
2-1/4
10
HLC-HX 5/8 x 6
5/8
1/2-13
10
3/4
5/8-11
1/2
10
3/4
5/8-11
1-3/4
10
3/4
5/8-11
3-3/4
10
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
Description
Bolt thread
Minimum
embedment
Fastens
materials up to
Qty / box
1/4
3/16-24
3/8
100
1/4
3/16-24
1-1/4
100
3.3.8
3.3.9
3.3.9
3.3.9
Bolt thread
Minimum
embedment
Fastens
materials up to
Qty / box
1/4
3/16-24
1-1/8
1-1/8
100
5/16
1/4-20
1-1/4
1/4
100
5/16
1/4-20
1-1/4
1-1/4
100
3/8
5/16-18
1-1/2
3/8
50
3/8
5/16-18
1-1/2
1-1/2
50
Description
3.3.9
3.3.9
3.3.14
3.3.9
A
Rod coupling (RC)
Nominal
bit diameter
Bolt thread
Minimum
embedment
Fastens
materials up to
3/8
5/16-18
1-1/4
5/16 x 3/8
50
1/2
3/8-16
1-1/2
3/8 x 1/2
25
Description
Qty / box
Definition of nomenclature
Outside diameter of sleeve, see tables
for threaded bolt diameter
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 299
Product description
3.3.15.2
Material specifications
3.3.15.3
Technical data
3.3.15.4
Installation instructions
3.3.15.5
Ordering information
Guide specifications
Concrete screw anchors
Concrete or masonry screw anchors
shall be manufactured from cold rolled
steel case hardened to a minimum
Rockwell Hardness C 45 or stainless
steel conforming to AISI Type 410. The
concrete or masonry screw anchors
shall have a trilobular, cold formed
thread design and 8 threads per inch.
Screw anchors shall have one of the
following head designs: Tapered flat
head with T-25 TORX recess,Tapered
flat head with T-27 TORX recess or
5/16-inch hex washer with internal
T-25 TORX recess. Carbon steel achors
are finished with corrosion resistant
silver KWIK Cote coating. Anchors
shall be Hilti KWIK-CON II+ anchors as
supplied by Hilti.
Installation
Concrete or masonry screw anchors
shall be installed in holes drilled with
matched tolerance Hilti carbide-tipped
drill bits supplied with each box of
KWIK-CON II+ anchors. Installation shall
be in accordance with manufacturers
installation instructions.
Listings/Approvals
Metro-Dade County
NOA 12-0625.05
300 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
3.3.1
Head Styles
Tapered flat head with #3 Phillips recess for 3/16- and 1/4-in. anchors.
Tapered flat head with T-25 TORX recess for 3/16-in. anchor.
Tapered flat head with T-27 TORX recess for 1/4-in. anchor.
5/16-in. hex washer with internal T-25 TORX recess for 3/16- and 1/4-in. anchors.
3.3.2
Head diameter
Maximum 0.507 in. for 3/16- and 1/4-in. tapered Philliips flat head and 1/4-in. tapered T-27 TORX flat head anchors.
Maximum 0.385 in. for 3/16-in. tapered T-25 TORX flat head anchor.
Maximum 0.432 in. maximum for 3/16- and 1/4-in. T-25 TORX hex washer head anchors.
3.3.5
Thread diameter
Nominal 3/16-in., Major dia. is 0.217 inches, Minor2 is 0.145 inches.
3.3.3
3.3.4
3.3.6
3.3.7
3.3.8
Shank diameter
Nominal 3/16-in. is 0.170 inches.
Nominal 1/4-in. is 0.224 inches.
3.3.9
Lengths (in.)
1-1/4, 1-3/4, 2-1/4, 2-3/4, 3-1/4, 3-3/4, 4 (See ordering information section).
3.3.9
Thread design
Trilobular, cold formed.
Threads per inch
Nominal 3/16-in. have 8 tpi.
Nominal 1/4-in. have 8 tpi.
Inches of thread per fastener
1.875 inches maximum.
3.3.9
3.3.9
3.3.9
3.3.9
3.3.15
Bending capacity
Ductility at 10 minimum.
1 Minimum tensile and yield strength are the average of strength measurement of (30) tested samples. These are not minimum steel properties
or minimum manufacturing specifications.
2 Minor diameter is the average measurement taken from (30) samples. This is not a controlled dimension.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 301
Nominal
embedment
in. (mm)
1
(25)
1-3/4
(44)
1
(25)
1-3/4
(44)
3/16
3/16
1/4
1/4
Tension
lb (kN)
100
(0.44)
275
(1.22)
190
(0.85)
425
(1.89)
Shear
lb (kN)
260
(1.16)
260
(1.16)
325
(1.45)
560
(2.49)
Tension
lb (kN)
125
(0.56)
295
(1.31)
240
(1.07)
625
(2.78)
Shear
lb (kN)
260
(1.16)
265
(1.18)
390
(1.73)
600
(2.82)
Tension
lb (kN)
185
(0.82)
325
(1.45)
275
(1.22)
650
(2.89)
Shear
lb (kN)
280
(1.25)
300
(1.33)
540
(2.40)
600
(2.67)
Nominal
embedment
in. (mm)
1
(25)
1-3/4
(44)
1
(25)
1-3/4
(44)
3/16
3/16
1/4
1/4
Tension
lb (kN)
400
(1.78)
1,100
(4.89)
760
(3.38)
1,700
(7.56)
Shear
lb (kN)
1,050
(4.67)
1,050
(4.67)
1,300
(5.78)
2,250
(10.0)
Tension
lb (kN)
500
(2.22)
1,180
(5.25)
970
(4.31)
2,500
(11.1)
Shear
lb (kN)
1,050
(4.67)
1,070
(4.76)
1,575
(7.01)
2,400
(11.3)
Tension
lb (kN)
750
(3.34)
1,300
(5.78)
1,100
(4.89)
2,600
(11.6)
Shear
lb (kN)
1,150
(5.12)
1,200
(5.34)
2,175
(9.68)
2,400
(10.7)
Nominal
embedment
in. (mm)
1
(25)
1-3/4
(44)
1
(25)
1-3/4
(44)
Tension
lb (kN)
150
(0.67)
290
(1.29)
165
(0.73)
310
(1.38)
1 All values for anchors installed in hollow concrete masonry with a minimum
prism strength of 1,500 psi. Concrete block may be lightweight, mediumweight or normal-weight conforming to ASTM C90.
2 Screws installed in holes drilled with TKB bits.
3 Allowable loads calculated using a factor of safety of 4.
Nominal
anchor
diameter
3/16
3/16
1/4
1/4
Nominal
embedment
in. (mm)
1
(25)
1-3/4
(44)
1
(25)
1-3/4
(44)
Tension
lb (kN)
125
(0.56)
350
(1.56)
205
(0.91)
350
(1.56)
Shear
lb (kN)
235
(1.05)
300
(1.33)
415
(1.85)
500
(2.22)
1 This test was performed on individual specimens of ASTM C62 common red
brick. Due to the wide variations encountered in the compressive strength of
brick, these values should be considered guide values.
2 Allowable loads are based on a safety factor of 4.
The anchors are installed a minimum of 12 diameters on center with a minimum edge distance of six diameters for 100 percent
anchor efficiency. Spacing and edge distance may be reduced to six diameter spacing and three diameter edge distance
providing values are reduced 50 percent. Linear interpolation may be used for intermediate spacing and edge margins.
Combined shear and tension loading
( ) ( )
Nd
Nd
Vd
Vd
1.0
Diameter
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
Total length
1-1/4
1-1/4
1-3/4
1-3/4
2-1/4
2-3/4
2-3/4
3-1/4
3-3/4
4
Thread length
1-1/4
1-1/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
Shank length
0
0
0
0
1/2
1
1
1-1/2
2
2-1/4
3.3.1
3.3.2
3.3.3
Diameter
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
Total length
1-1/4
1-1/4
1-3/4
1-3/4
2-1/4
2-3/4
2-3/4
3-1/4
3-3/4
3-3/4
4
1-1/4
2-3/4
Thread length
1-1/4
1-1/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-1/4
1-3/4
Shank length
0
0
0
0
1/2
1
1
1-1/2
2
2
2-1/4
0
1
Diameter
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
Total length
1-1/4
1-3/4
1-3/4
2-1/4
2-3/4
2-3/4
3-1/4
3-3/4
3-3/4
4
Thread length
1-1/8
1-5/8
1-5/8
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
Shank length
0
0
0
3/8
7/8
7/8
1-3/8
1-7/8
1-7/8
2-1/8
Diameter
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
Total length
1-1/4
1-3/4
1-3/4
2-1/4
2-3/4
3-1/4
3-1/4
3-3/4
4
Thread length
1-1/16
1-9/16
1-9/16
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
Shank length
0
0
0
5/16
13/16
1-5/16
1-5/16
1-13/16
2-1/16
3.3.4
3.3.5
3.3.6
3.3.7
3.3.8
3.3.9
3.3.9
3.3.9
T-25 TORXbit
Description
KWIK-CON II+ 316-114 TFH
KWIK-CON II+ 316-134 TFH
KWIK-CON II+ 316-134 TFH Bulk
KWIK-CON II+ 316-214 TFH
KWIK-CON II+ 316-234 TFH
KWIK-CON II+ 316-234 TFH Bulk
KWIK-CON II+ 316-314 TFH
KWIK-CON II+ 316-334 TFH
KWIK-CON II+ 316-334 TFH Bulk
KWIK-CON II+ 316-4 TFH
3.3.9
3.3.9
3.3.9
3.3.15
T-27 TORXbit
Description
KWIK-CON II+ 14-114 TFH
KWIK-CON II+ 14-134 TFH
KWIK-CON II+ 14-134 TFH Bulk
KWIK-CON II+ 14-214 TFH
KWIK-CON II+ 14-234 TFH
KWIK-CON II+ 14-314 TFH
KWIK-CON II+ 14-314 TFH Bulk
KWIK-CON II+ 14-334 TFH
KWIK-CON II+ 14-4 TFH
1 All dimensions in inches.
Total Length
Thread length
Total Length
Shank
length
Thread length
Shank
length
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 303
Diameter
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
Total length
1-1/4
1-3/4
2-1/4
2-3/4
3-1/4
3-3/4
4
1-1/4
2-3/4
Thread length
1-1/16
1-9/16
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
1-1/16
1-3/4
Shank length
0
0
5/16
13/16
1-5/16
1-13/16
2-1/16
0
13/16
Diameter
1/4
1/4
1/4
1/4
1/4
1/4
1/4
Total length
1-1/4
1-3/4
2-1/4
2-3/4
3-1/4
3-3/4
4
Thread length
1-1/16
1-9/16
1-3/4
1-3/4
1-3/4
1-3/4
1-3/4
Shank length
0
0
5/16
13/16
1-5/16
1-13/16
2-1/16
#3 Phillipsbit
Description
KWIK-CON II+ 14-114 PFH
KWIK-CON II+ 14-134 PFH
KWIK-CON II+ 14-214 PFH
KWIK-CON II+ 14-234 PFH
KWIK-CON II+ 14-314 PFH
KWIK-CON II+ 14-334 PFH
KWIK-CON II+ 14-4 PFH
Qty / pack
1
1
1
1
1
1
1
1
Total Length
Thread length
Shank
length
Thread length
Shank
length
Reference
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 305
Reference
4.0 Reference
4.1 Approvals and listings
4.1.1 ICC-ES
(International
Code Council)
Evaluation Reports
Report No. Title
ESR-1385
Research
Report. Title
25939
Hilti HDA Carbon Steel and Stainless Steel
Undercut Anchors for Cracked and Uncracked
Concrete
25947
25964
4.1.3 Miami-Dade
County Approvals
NOA Title
ESR-3056
ESR-3187
ESR-3342
ESR-3574
ESR-2302
ESR-2322
4.1.2 COLA
(City of Los Angeles)
Approvals
Research
Report. Title
25577M
25700
Hilti HIT-RE 500-SD Adhesive Anchors in
Concrete
25701
25897
25901
25903
KH-EZ I 3/8-in.
306 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
A193
A307
A370
A563
A615
Standard Specification for Deformed and
Plain Carbon-Steel Bars for Concrete
Reinforcement
Standard Title
C881
C882
C942
D638
D648
D695
E8
E119
A653
B117
E488
B695
C31
E1190
C33
E1512
C34
C39
C42
C62
C90
C150
C270
C330
C332
C652
F436
Standard Specification for Hardened Steel
Washers
F593
F594
F606
F844
F1554
G85
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 307
Reference
B633
B695
B18.22.1
B212.15
308 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
To convert
Into
Length
inch (in.)
foot (ft)
millimeter (mm)
meter (m)
Area
square inch (in2)
square inch (in2)
square foot (ft2)
645.1600
6.4516
0.0929
Volume
cubic inch (in3)
cubic foot (ft3)
gallon (USgal)
16.3871
0.0283
3.7854
Force
pound force (lbf)
pound force (lbf)
newton (N)
kilonewton (kN)
4.4482
0.0044
newton/square millimeter
(N/mm2)
mega pascal (MPa)
mega pascal (MPa)
0.0069
Pressure
pound/square inch (psi)
pound/square inch (psi)
Kip/square inch (ksi)
pounds/square foot
(psf)
in.
Hard metric
conversion
mm
1/4
6.35
5/16
7.94
3/8
9.52
10
1/2
12.70
12
5/8
15.88
16
3/4
19.05
20
25.40
25
To convert
1-1/4
31.75
32
Length
newton/square meter
(N/m2)
newton/meter (N/m)
Multiply by
25.4000
0.3048
0.0069
6.8946
47.8801
1.3558
0.1130
14.5939
Multiply by
millimeter (mm)
inch (in.)
0.0394
meter (m)
foot (ft)
3.2808
0.0016
0.1550
10.7639
Area
2
Volume
cubic centimeter (cm3)
0.0610
35.3147
liter (L)
gallon (USgal)
0.2642
Force
newton (N)
0.2248
kilonewton (kN)
224.8089
newton/square
millimeter (N/mm2)
145.0400
145.0400
0.1450
newton/square meter
(N/m2)
0.0209
Pressure
0.7376
8.8496
0.0685
Diaphragm Shear
newton/meter (N/m)
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 309
Reference
Nominal size
in.
ksi
(MPa)
ksi
(MPa)
All
1/4 thru 2-1/2
1/4 thru 1-1/4
over 5/8 thru 1
1/4 thru 5/8
5/8 thru 1-1/2
1/4 thru 3/4
1/4 thru 4
1/2 thru 1
over 1 thru 1-1/2
1/4 thru 1
over 1 thru 1-1/2
3/8 thru 3/4
1/4 thru 3/4
over 3/4 thru 1-1/2
1/4 thru 1
over 1 thru 1-1/2
1/4 thru 1-1/2
All
All
36
105
41
75
44
60
44
92
81
92
81
70
57
36
92
81
130
58
92.8
(248)
(724)
(282)
(517)
(303)
(414)
(303)
(634)
(558)
(634)
(558)
(480)
(393)
(248)
(634)
(558)
(896)
(400)
(640)
58
125
75
90
53
78
53
60
120
105
120
105
87
74
60
120
105
150
72.5
116
(400)
(862)
(517)
(620)
(365)
(538)
(365)
(414)
(827)
(724)
(827)
(724)
(600)
(510)
(414)
(827)
(724)
(1034)
(500)
(800)
Nominal size
Yield strength
Ultimate strength
in.
ksi
(MPa)
ksi
(MPa)
65
45
30
76
64
76
64
60
60
65.3
(448)
(310)
(205)
(524)
(441)
(524)
(441)
(414)
(414)
(450)
100
85
75
90
75
90
75
90
100
101.5
(689)
(586)
(515)
(620)
(524)
(620)
(524)
(627)
(689)
(700)
310 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
Area
Nominal size
Major
in. (D)
Minor
in.
Threads
per
Inch (n)
Nominal
in2
Minor1
in2
Tensile stress2
in2
No. 10
0.1900
0.1449
24
0.0284
0.0145
0.0175
No. 12
0.2160
0.1709
24
0.0366
0.0206
0.0242
1/4
0.2500
0.1959
20
0.0491
0.0269
0.0318
5/16
0.3125
0.2524
18
0.0767
0.0454
0.0524
3/8
0.3750
0.3073
16
0.1104
0.0678
0.0775
7/16
0.4375
0.3602
14
0.1503
0.0933
0.1063
1/2
0.5000
0.4167
13
0.1963
0.1257
0.1419
9/16
0.5625
0.4723
12
0.2485
0.1620
0.1819
5/8
0.6250
0.5266
11
0.3068
0.2017
0.2260
3/4
0.7500
0.6417
10
0.4418
0.3019
0.3345
7/8
0.8750
0.7547
0.6013
0.4192
0.4617
1.0000
0.8647
0.7854
0.5509
0.6057
1-1/8
1.1250
0.9704
0.9940
0.6929
0.7633
1-1/4
1.2500
1.0954
1.2272
0.8896
0.9691
Table 7 - Basic dimensions for M profile metric thread series ANSI B1.13M-1979
Basic diameter
Nominal size
Area
Major
mm (D)
Minor
mm
Thread
pitch
mm (P)
Nominal
mm2
Tensile stress1
mm2
M8
6.62
1.25
50.3
36.6
M10
10
8.34
1.50
78.5
58.0
M12
12
10.07
1.75
113.1
84.3
M16
16
13.80
2.00
201.1
157.0
M20
20
17.25
2.50
314.2
245.0
M24
24
20.70
3.00
452.4
353.0
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 311
Reference
Bar
designation
No.1
Nominal
weight
lb/ft
Diameter
in.
Area
in2
Perimeter
in.
0.376
0.375
0.11
1.178
0.668
0.500
0.20
1.571
1.043
0.625
0.31
1.963
1.502
0.750
0.44
2.356
2.044
0.875
0.60
2.749
2.670
1.000
0.79
3.142
3.400
1.128
1.00
3.544
10
4.303
1.270
1.27
3.990
11
5.313
1.410
1.56
4.430
14
7.65
1.693
2.25
5.32
18
13.60
2.257
4.00
7.09
1 Bar designation numbers are based on the number of eighths of an inch included in the nominal diameter.
2 The nominal dimensions of a deformed bar are approximate, being shown as equivalent to those of a plain round bar
having the same weight per foot as the deformed bar.
Table 9 - ASTM basic dimensions for deformed steel bars for concrete reinforcement, SI units
Bar
designation
No.1
Nominal
mass
kg/m
10
0.560
13
0.994
16
1.552
19
Nominal dimensions2
Diameter
mm
Area
mm2
Perimeter
mm
9.5
71
29.9
12.7
129
39.9
15.9
199
49.9
2.235
19.1
284
59.8
22
3.042
22.2
387
69.8
25
3.973
25.4
510
79.8
29
5.060
28.7
645
90.0
32
6.404
32.3
819
101.3
36
7.907
35.8
1006
112.5
43
11.38
43.0
1452
135.1
57
20.24
57.3
2581
180.0
1 Bar designation numbers approximate the number of millimeters of the nominal diameter of the bar.
2 The nominal dimensions of a deformed bar are approximate, being shown as equivalent to those of a plain round bar
having the same mass per meter as the deformed bar.
312 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
Net 30 days from date of invoice. Customer agrees to pay all costs incurred by Hilti in collecting any delinquent
amounts, including attorneys fees.
Freight:
All sales are F.O.B. Destination with transportation allowed via Hilti designated mode. Delivery dates are
estimates only and Customer accepts all risks associated with any delay, even if Hilti is advised that time is of
the essence. Additional charges for expedited shipments, special handling requirements, and orders below
certain dollar amounts shall be the responsibility of Customer. Fuel surcharges may apply depending on market
conditions.
Credit:
Return Policy:
Products must be in saleable condition to qualify for return. Saleable condition is defined as unused items in
original undamaged packaging and unbroken quantities and in as-new condition. All returns are subject to Hilti
inspection and acceptance, and a $125 restocking charge if returned more than 90 days after invoice date.
Proof of purchase is required for all returned materials.
Ineligible Return:
Special order products and discontinued items are not eligible for return or credit. Dated materials are only
returnable in case quantity and within 14 days after invoice date. In no event shall any product be returnable or
qualify for credit after 1 year from invoice date.
Warranty:
Hilti warrants that for a period of 12 months from the date it first supplies a product it will, at its sole option and
discretion, refund the purchase price of, repair, or provide a replacement for, such product which contains a
defect in material or workmanship. Hilti warrants that for a period of 12 months from the date it first supplies a
service, it will, at its sole option and discretion, refund the purchase price of, or reperform, such portion of the
service that does not conform to the contract requirements. Absence of Hiltis receipt of notification of any such
defect or nonconformance within this 12-month period shall constitute a waiver of all claims with regard to such
product and service.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hilti shall in no event be liable for, and Customer hereby
agrees to indemnify Hilti against, all claims related to special, direct, indirect, incidental, consequential, and any other damages arising out of or related
to the sale, use, or inability to use the product, including costs and attorneys fees, even if caused in whole or in part by the negligence of Hilti.
Order
Acceptance:
Acceptance is limited to the express terms contained herein, and terms are subject to change by Hilti without
notice. Terms and Conditions of Sale may be viewed at www.us.hilti.com. Additional or different terms
proposed by Customer are deemed material and are objected to and rejected, but such rejection shall not
operate as a rejection of the offer unless it contains variances in the terms of the description, quantity, price
or delivery schedule of the goods. Orders are not deemed accepted by Hilti unless and until it ships the
associated items if a partial shipment occurs, only that part of the order is deemed accepted.
Domestic Origin:
Origin information may be obtained by written request to Hilti, Inc., Contract Compliance, P. O. Box 21148,
Tulsa, Oklahoma 74121. Hiltis Quality Department personnel are the only individuals authorized to warrant the
country of origin of Hilti products.
Business Size:
Prices:
Prices are those stated on the order, and unless otherwise noted are based on purchasing all items on the order
pricing for individual products may vary for purchases of different quantities or item combinations. Hilti does
not maintain most favored customer records, makes no representation with respect to same, and rejects any
price warranty terms proposed by Customer. Hilti's published net price list is subject to change without notice.
Consent to
Jurisdiction:
All transactions shall be deemed to have been made and entered into in Tulsa, Oklahoma. Any and all disputes
arising directly or indirectly from such transactions shall be resolved in the courts of the County of Tulsa, State of
Oklahoma, to the exclusion of any other court, and any resulting judgment may be enforced by any court having
jurisdiction of such an action. All transactions shall be governed by and construed in accordance with the laws
of the State of Oklahoma.
Indemnification:
Customer hereby agrees to indemnify Hilti for any costs, including attorneys fees, incurred by Hilti as a
result, in whole or in part, of any violation by Customer of any Federal, State or Local statute or regulation, or
of any nationally accepted standard. It shall be Customers sole responsibility to comply with all applicable
laws, regulations, and codes regarding the handling, use, transportation, or disposal of products upon taking
possession of same.
Insurance:
Hiltis insurance is reflected on the Certificate of Insurance available at www.us.hilti.com, which contains what is
current at that particular time. In no event shall Hilti be obligated to continue to provide the same insurance or
any other insurance, including coverage, limits, or deductibles.
Convert Check
to EFT:
When Customer provides a check as payment, it authorizes Hilti to use information from the check to make a
one time electronic funds transfer from Customers checking account or to process the payment as a check
transaction. When Hilti uses information from Customers check to make an electronic funds transfer, funds may
be withdrawn from the account as soon as the same day the check is received, and Customer will not receive its
check back from the financial institution.
Authorization:
HILTI LEGAL DEPARTMENT PERSONNEL ARE THE ONLY INDIVIDUALS AUTHORIZED TO MODIFY THESE
TERMS AND CONDITIONS, WARRANT PRODUCT SUITABILITY FOR SPECIFIC APPLICATIONS, ACCEPT
INFORMATION ON THE POTENTIAL FOR CONSEQUENTIAL DAMAGES, OR EXECUTE CUSTOMER
DOCUMENTS, AND ANY SUCH ACTION IS NULL AND VOID UNLESS IN WRITTEN FORM SIGNED BY SUCH
INDIVIDUAL SPECIFICALLY INDICATING THE INTENT TO MODIFY THESE TERMS AND CONDITIONS OF
SALE. HILTI SALES REPRESENTATIVES (INCLUDING ACCOUNT MANAGERS, REGIONAL MANAGERS, AND
CUSTOMER SERVICE REPRESENTATIVES) HAVE NO SUCH AUTHORITY.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 313
Reference
Payment Terms:
Net 30 days from date of invoice. Customer agrees to pay all costs incurred by Hilti in collecting any delinquent
amounts, including attorneys fees.
Freight:
All sales are F.O.B. Destination with transportation allowed via Hilti designated mode. Delivery dates are All All
sales are F.O.B. Destination with transportation allowed via Hilti designated mode. Delivery dates are estimates
only and Customer accepts all risks associated with any delay, even if Hilti is advised that time is of the essence.
Additional charges for expedited shipments, special handling requirements, and orders below certain dollar
amounts shall be the responsibility of Customer. Fuel surcharges may apply depending on market conditions.
Credit:
Return Policy:
Products must be in saleable condition to qualify for return. Saleable condition is defined as unused items in
original undamaged packaging and unbroken quantities and in as-new condition. All returns are subject to Hilti
inspection and acceptance, and a $150 restocking charge if returned more than 90 days after invoice date.
Proof of purchase is required for all returned materials.
Ineligible Return:
Special order products and discontinued items are not eligible for return or credit. Dated materials are only
returnable in case quantity and within 14 days after invoice date. In no event shall any product be returnable or
qualify for credit after 1 year from invoice date.
Warranty:
Hilti warrants that for a period of 12 months from the date it first supplies a product it will, at its sole option and
discretion, refund the purchase price of, repair, or provide a replacement for, such product which contains a
defect in material or workmanship. Hilti warrants that for a period of 12 months from the date it first supplies a
service, it will, at its sole option and discretion, refund the purchase price of, or reperform, such portion of the
service that does not conform to the contract requirements. Absence of Hiltis receipt of notification of any such
defect or nonconformance within this 12-month period shall constitute a waiver of all claims with regard to such
product and service.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hilti shall in no event be liable for, and Customer hereby
agrees to indemnify Hilti against, all claims related to special, direct, indirect, incidental, consequential, and any other damages arising out of or related
to the sale, use, or inability to use the product, including costs and attorneys fees, even if caused in whole or in part by the negligence of Hilti.
Order
Acceptance:
Acceptance is limited to the express terms contained herein, and terms are subject to change by Hilti without
notice. Terms and Conditions of Sale may be viewed at www.hilti.ca. Additional or different terms proposed
by Customer are deemed material and are objected to and rejected, but such rejection shall not operate as
a rejection of the offer unless it contains variances in the terms of the description, quantity, price or delivery
schedule of the goods. Orders are not deemed accepted by Hilti unless and until it ships the associated items
if a partial shipment occurs, only that part of the order is deemed accepted.
Domestic Origin:
Origin information may be obtained by written request to Hilti, Inc., Contract Compliance, P. O. Box 21148,
Tulsa, Oklahoma 74121. Hiltis Quality Department personnel are the only individuals authorized to warrant the
country of origin of Hilti products.
Business Size:
Prices:
Prices are those stated on the order, and unless otherwise noted are based on purchasing all items on the order
pricing for individual products may vary for purchases of different quantities or item combinations. Hilti does
not maintain most favored customer records, makes no representation with respect to same, and rejects any
price warranty terms proposed by Customer. Hilti's published net price list is subject to change without notice.
Consent to
Jurisdiction:
All transactions shall be deemed to have been made and entered into in Tulsa, Oklahoma. Any and all disputes
arising directly or indirectly from such transactions shall be resolved in the courts of the County of Tulsa, State of
Oklahoma, to the exclusion of any other court, and any resulting judgment may be enforced by any court having
jurisdiction of such an action. All transactions shall be governed by and construed in accordance with the laws
of the State of Oklahoma.
Indemnification:
Customer hereby agrees to indemnify Hilti for any costs, including attorneys fees, incurred by Hilti as a
result, in whole or in part, of any violation by Customer of any Federal, State or Local statute or regulation, or
of any nationally accepted standard. It shall be Customers sole responsibility to comply with all applicable
laws, regulations, and codes regarding the handling, use, transportation, or disposal of products upon taking
possession of same.
Insurance:
Hiltis insurance is reflected on the Certificate of Insurance available at www.us.hilti.com, which contains what is
current at that particular time. In no event shall Hilti be obligated to continue to provide the same insurance or
any other insurance, including coverage, limits, or deductibles.
Convert Check
to EFT:
When Customer provides a check as payment, it authorizes Hilti to use information from the check to make a
one time electronic funds transfer from Customers checking account or to process the payment as a check
transaction. When Hilti uses information from Customers check to make an electronic funds transfer, funds may
be withdrawn from the account as soon as the same day the check is received, and Customer will not receive its
check back from the financial institution.
Authorization:
HILTI LEGAL DEPARTMENT PERSONNEL ARE THE ONLY INDIVIDUALS AUTHORIZED TO MODIFY THESE
TERMS AND CONDITIONS, WARRANT PRODUCT SUITABILITY FOR SPECIFIC APPLICATIONS, ACCEPT
INFORMATION ON THE POTENTIAL FOR CONSEQUENTIAL DAMAGES, OR EXECUTE CUSTOMER
DOCUMENTS, AND ANY SUCH ACTION IS NULL AND VOID UNLESS IN WRITTEN FORM SIGNED BY SUCH
INDIVIDUAL SPECIFICALLY INDICATING THE INTENT TO MODIFY THESE TERMS AND CONDITIONS OF
SALE. HILTI SALES REPRESENTATIVES (INCLUDING ACCOUNT MANAGERS, REGIONAL MANAGERS, AND
CUSTOMER SERVICE REPRESENTATIVES) HAVE NO SUCH AUTHORITY.
314 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 315
Reference
Notes
316 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 317
Reference
Notes
318 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
Reference
Notes
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014 319
Reference
Notes
320 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2014
PROFIS Anchor
software
Engineering
Services
Anchor design at
a click.
A guide to specification
and installation
*ISO 14001 US Only