40LX - PRODUCT DATA DIGEST

DIRECT
EXPANSION
FAN-COIL
UNITS

QUALITY SYSTEM

MALAYSIA
MS ISO 9001
REG. NO: AR 0239

Any room, every room flexibility in an air conditioning system


FEATURES:
Direct Expansion Furred-in model with Plenum Fan Coil units.
The low silhouette styling of this unit makes it a popular choice for in-the-ceiling or over the closet
applications in all types of building.
Horizontal ducted application.
Insulated & painted condensate drain pan and a factory fitted frame complete with filter media.
Installed with direct driven forward curved centrifugal fans and 3 speed motor ensures quiet operation.
Flare fittings - easy & quick installation (40LX040-060).
Standard copper tube aluminium fins (Cu/Al) evaporator coil for maximum heat transfer.
Carrier Lanced Sine Wave fin pattern ensures high EER performance.
Factory supplied expansion devices, accurator.
Units shall be manufactured as left-hand side (in the direction of air flow) piping connection as standard.

SPECIFICATIONS
MODEL

TYPE
INDOOR
OUTDOOR
(kW)
(kW)
(A)

NOMINAL CAPACITY*
SYSTEM INPUT kW*
SYSTEM RUNNING AMPS*
REFRIGERANT
POWER SOURCE (V-Ph-Hz) NOMINAL - INDOOR
MODEL
FAN
TYPE
NUMBER
DRIVE
I
FAN MOTOR
NUMBER
N
INPUT (kW)
D
FLA (A)
O
RUNNING AMPS (A)
O
NOMINAL AIR FLOW
(l/s)
R
INDOOR COIL
ROW - FINS/m
DIMENSIONS
DEPTH, D(mm)
U
WIDTH, W(mm)
N
HEIGHT, H(mm)
I
OPERATING WEIGHT
(kg)
T
SOUND PRESSURE LEVEL**
dB (A) @ H Speed
NO. OF FAN SPEEDS
EXTERNAL FINISH
FILTER
TYPE
MODEL
O
COMPRESSOR
LRA (A)
U
RLA (A)
T
RUNNING AMPS (A)*
D
FAN MOTOR
RUNNING AMPS (A)*
O
FLA (A)
O
CONDENSER COIL
ROWS-FINS/m
R
DIMENSIONS
WIDTH, W(mm)
LENGTH, L(mm)
U
HEIGHT, H(mm)
N
OPERATING WEIGHT
(kg)
I
EXTERNAL FINISH
T
SOUND PRESSURE LEVEL**
dB(A)

*
**

40LX040
38HDT036
11.7
3.85
8.4

40LX040

0.57
3.0
2.49
660
2-511

68
71.5

38HDT036
37
6.0
5.08
0.83
1.45
2-591
432
1130
945
95
65

DIRECT EXPANSION FAN COIL UNITS


40LX050
40LX060
40LX070
38HDT048
38HDT060
38HDT070
14.8
17.7
21.7
5.31
6.11
8.37
11.13
13.89
16.88
R-22
230-1-50
40LX050
40LX060
40LX070
CENTRIFUGAL FORWARD CURVED BLADES
1
2
DIRECT DRIVE
1
0.55
0.82
0.90
3.0
4.2
5.5
2.36
3.53
3.84
640
750
1050
3-589
4-669
3-589
680
1000
1200
480
70
72
95
71
71.5
72.7
3 SPEEDS
UNPAINTED GALVANIZED STEEL CASING
WASHABLE /THROWAWAY
38HDT048
38HDT060
38HDT070
55
70
69
7.8
10.6
16.4
7.28
8.88
11.53
1.49
1.48
1.51
1.45
1.45
1.45
2-591
2-591
3-591
432
432
432
1130
1130
1130
945
945
945
99
107
110
ALPINE MIST
66
67
67

FLA: FULL LOAD AMPS


LRA: LOCKED ROTOR AMPS
RLA: RATED LOAD AMPS
DATA RATED TO JIS STANDARD AT 350C (950F) AMBIENT 26.70C/19.40C (800F/670F) INDOOR CONDITION WHEN MATCHED WITH CARRIER APPROVED FAN COIL UNITS.
DATA IS MEASURED AT 1m UNDER CENTER OF THE UNIT (INDOOR UNIT) / 1m ABOVE THE GROUND (OUTDOOR UNIT).

ALL DIMENSION IS IN MM

PHYSICAL DIMENSION

A
357.6
335.1

Model Size
40LX040/050
40LX060
336.2

291.2

17.2

12.6

336.2

291.2

ALL DIMENSION IS IN MM

PHYSICAL DIMENSION

A
1160
1160
1560

Model No
40LX070
40LX090
40LX100

132.4 935.2

132.4 935.2

1200

1200

1349 287.4 1025.2 1600

949

949

1612

1212

1212

17.2

28.6

28.6

336.2

335.4

291.2

External Static Pressure (mm Aq)

External Static Pressure (mm Aq)

FAN PERFORMANCE

40LX040

Air Flow (l/s)

40LX050

Air Flow (l/s)

13

FAN PERFORMANCE (CONT)

External Static Pressure (mm Aq)

40LX060

14

SOUND PRESSURE LEVEL


OCTAVE BAND CENTRE FREQUENCY Hz

MODEL
40LX040

40LX050

63
47.1

125
54.5

250
57.9

500
66.4

1000
67.4

2000
67.1

4000
66.2

8000
59.4

dB(A)
71.5

44.3

46.3

50

60.3

60

58.9

57.2

49.5

65.9

35.8

40.7

43.9

55.9

53.9

53.3

50.3

41.2

60.1

43.5
40.8

51.1
42.9

54.2
46.6

63.4
55.1

64.2
55.6

64.1
54.5

68.0
52.8

56.4
45

71.0
66.2

33.5

38.3

41.8

52.1

50.2

49.7

46.6

37.6

63.2

48.2

58.7

60.0

58.0

66.8

64.3

63.6

60.8

71.5

45.0
39.8

55.0
49.0

55.5
49.3

53.6
49.2

61.6
56.6

60.2
55.2

59.6
53.9

56.5
49.7

67.0
61.6

46.8

54.1

56.9

66.0

67.1

66.3

64.5

59.1

72.7

M
L

44.9

46.9

49.8

59

59.2

57.8

56.9

46.8

67.1

36.8

41.3

44.7

56.5

54.7

53.8

50.2

41.9

60.5

H
M
L
H
M
L

40LX060

40LX070

40LX090

40LX100

H
M

47.7

54.6

57.9

66.9

67.9

67.5

66.7

60.0

73.4

M
L

45.5

47.6

51.3

61.8

61.9

60.8

59.1

51.3

67.6

37.2

42.0

45.1

57.2

55.3

54.8

51.8

42.8

61.7

48.2

58.0

62.6

66.9

67.5

65.3

63

59.8

73.1

M
L

44.6

53.2

56.7

62.1

62.2

59.3

56.7

51

66.4

40.1

47.2

50.5

56.1

56.5

55.1

50.7

42.8

61.9

Note: Break out sound pressure level at 1.0m infront & 1.0m below the fan discharge of the unit.

16

GUIDE SPECIFICATIONS
Furnish and install fan coil units in the location and
manner shown in IOM. Units shall be suitable for use
with 230V-1Ph-50Hz electrical supply.
The base units shall be completed with DX coil which
equipped with connections for both liquid and suction
line.
Units shall be complete with one or more centrifugal
fans, integral-high pitched condensate drain pan and
galvanized steel casing panels. It shall be internally
insulated on the discharge side of fan with 12.7mm
polyethylene.

Coils shall be constructed with lanced sine wave


aluminium plate fins mechanically bonded to 3/8"
(9.5mm) copper tubing with all joints brazed. Coil shall
be 2 rows (40LX040), 3 rows (40LX050, 070 & 100) or
4 rows (40LX060 & 090) deep with a nominal fin
spacing of 511 (40LX040), 589 (40LX050, 070, 090 &
100) or 669 (40LX060) per metre.
Fan(s) shall be centrifugal forward curve, direct driven
by a permanent split capacitor motor.
Drain pan shall be painted galvanized steel insulated
with 6.4mm thick polyethylene foam and pitch for
positive drainage with unit level.

Carrier
International
Sdn. Bhd.
Malaysia

Carrier International Sdn. Bhd. (3385-T)


Lot 4, Jalan P/6, Bandar Baru Bangi,
43650, Selangor, Malaysia.
Tel: 03-825 8001
Telex: MA 31610/MA 31614
Fax: 03-825 3578

40LX
1

40LXA - A97 - 1PD

20

NEW
97

Manufacturer reserves the right to discontinue, or


change at any time, specifications or designs
without notice and without incurring obligations.

Potrebbero piacerti anche