Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Section 9
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-1
Section 9
9-2
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Top- or Bottom-Feed
800-4000 Amperes - 600 Vac Max.
HPC Switches with Electric Trip
For use with Ground Break components or for remote tripping. Fuses not included.
For resistance-grounded systems or where zone selective interlocking is required, electric
trip HPC switches with Ground Break system components are recommended.
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Ampere
Rating
Control
Voltage
Net Weight,
Lbs. (Approx.)
Product
Number
800A
1200A
1600A
2000A
2500A
3000A
4000A
800A
1200A
1600A
2000A
2500A
3000A
4000A
800A
1200A
1600A
2000A
2500A
3000A
4000A
800A
1200A
1600A
2000A
2500A
3000A
4000A
120-240Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
120-240Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
480-600Vac
75
80
80
165
180
180
505
75
80
80
165
180
180
505
75
80
80
165
180
180
505
75
80
80
165
180
180
505
THPR3608ET1
THPR3612ET1
THPR3616ET1
THPC3620ET1
THPC3625ET1
THPC3630ET1
THPC3640ET1
THPR3608ET2
THPR3612ET2
THPR3616ET2
THPC3620ET2
THPC3625ET2
THPC3630ET2
THPC3640ET2
THPR3608BET1
THPR3612BET1
THPR3616BET1
THPC3620BET1
THPC3625BET1
THPC3630BET1
THPC3640BET1
THPR3608BET2
THPR3612BET2
THPR3616BET2
THPC3620BET2
THPC3625BET2
THPC3630BET2
THPC3640BET2
PA N O
G TE
PR E 9 :
O -6 OB
D F S
U O O
CT R LE
N NE TE
U W ,
M
SE
BE H E
RS P C
Source
Configuration
For service or feeder disconnects not requiring ground fault protection. Includes fusemounting hardware and door-catch interlock bracket. Fuses not included.
Source
Configuration
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Rev. 11/13
Data subject to change
without notice
Ampere
Rating
Net Weight
Lbs. (Approx.)
Product
Number
800A
1200A
1600A
2000A
2500A
3000A
4000A
800A
1200A
1600A
2000A
2500A
3000A
4000A
75
80
80
165
180
180
505
75
80
80
165
180
180
505
THPR3608
THPR3612
THPR3616
THPC3620
THPC3625
THPC3630
THPC3640
THPR3608B
THPR3612B
THPR3616B
THPC3620B
THPC3625B
THPC3630B
THPC3640B
www.geindustrial.com
BuyLog Catalog
9-3
Section 9
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Ampere
Rating
Net Weight
Lbs. (Approx.)
800A
1200A
1600A
2000A
2500A
3000A
4000A
800A
1200A
1600A
2000A
2500A
3000A
4000A
105
105
105
195
210
210
540
105
105
105
195
210
210
540
Product
Number
THPR3608G3T
THPR3612G3T
THPR3616G3T
THPC3620G3T
THPC3625G3T
THPC3630G3T
THPC3640G3T
THPR3608BG3T
THPR3612BG3T
THPR3616BG3T
THPC3620BG3T
THPC3625BG3T
THPC3630BG3T
THPC3640BG3T
PA N O
G TE
PR E 9 :
O -6 OB
D F S
U O O
CT R LE
N NE TE
U W ,
M
SE
BE H E
RS P C
.
Source
Configuration
HPC Switches with Integral Ground Fault Alarm only for Solidly Grounded Systems
Integral Ground Fault with 3-Phase Sensor, Adjustable Pick-up, Adjustable Time-Delay,
Test Function, and Mechanical Ground Fault Indicator
Source
Configuration
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Top Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Bottom Feed
Ampere
Rating
Net Weight
Lbs. (Approx.)
800A
1200A
1600A
2000A
2500A
3000A
4000A
800A
1200A
1600A
2000A
2500A
3000A
4000A
105
105
105
195
210
210
540
105
105
105
195
210
210
540
Product
Number
THPR3608GA3
THPR3612GA3
THPR3616GA3
THPC3620GA3
THPC3625GA3
THPC3630GA3
THPC3640GA3
THPR3608BGA3
THPR3612BGA3
THPR3616BGA3
THPC3620BGA3
THPC3625BGA3
THPC3630BGA3
THPC3640BGA3
Includes fuse-mounting hardware and door-catch interlock bracket. (Fuses not included)
NOTE: The 800-3000 ampere integral ground fault HPC switches can easily be installed in the space occupied by
a manual HPC switch of the same ampere rating. The 4000 ampere switch, being 3 inches wider, may require
some modification.
NOTE: Integral ground fault tripping is accomplished by a low-energy, flux-shifting tripping mechanism and is
not suitable for remote (paralleled) tripping. If remote tripping is required, add suffix RT1 120-240Vac or
RT2 480-600Vac to above product number.
9-4
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Thermal Rating
(Amperes)
Weight
(Lbs.)
Product
Number
Solid
Solid
Solid
Split
Split
1600
2500
3000
4000
4000
3
4
7
15
25
TGS0002
TGS0005
TGS0008
TGS0408
TGS0808
N
O
O T
H NL E:
PC Y R
,
EP
T
U
SE UR SW SE L A
E E I D C
PA D T C F E M
IN G PR H OR E
ST E 9 IO ES O NT
AL -2 R M R P
L A 1 TO A N I G I A R
TI FO 2 UF NA TS
O R 01 A L
N N 4 C
S. E . W
2.5 Dia.
5 Dia.
8 Dia.
4 x 8
8 x 8
Core
Construction
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-5
Section 9
SH P
Char 1-3
Char 4
Char 5
Char 6
Char 7
Char 8
Char 9
Char 10
Char 11
Char 12
Char 13
Char 14
Char 15
Auxiliary Switch,
Trimplate
1 = 4-240V, None
Fusible Switch
SHP = HPC
New Generation
Closing Solenoid,
Door Interlock, Counter
8 = None, Yes, None
Frame Size
R = Small Frame
Feed
T = Top
Frame Rating
3 = 800A
Bell Alarm, Bell Alarm with Lock Out, Kirk Key Protection
0 = None, None, None
TU Protection
3 = Ground Fault
Switch Rating
N = 800A
Character 4
R
C
L
Character 5 Feed
Character 5
T
B
Top
Bottom
800A
1600A
2000A
2500A
3000A
4000A
9-6
BuyLog Catalog
Metering
Current
Current
Current
Current
Adv & WFC
Adv & WFC
Adv & WFC
Adv & WFC
Current
Current
Current
Current
Adv & WFC
Adv & WFC
Adv & WFC
Adv & WFC
Current
Current
Current
Current
Adv & WFC
Adv & WFC
Adv & WFC
Adv & WFC
RELT
None
RELT
RELT
None
RELT
None
RELT
None
None
RELT
RELT
None
RELT
None
RELT
None
None
RELT
RELT
None
RELT
None
RELT
None
www.geindustrial.com
Comm
None
None
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
None
None
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
None
None
Modbus
Modbus
Modbus
Modbus
Modbus
Modbus
Relays
None
None
None
None
None
None
Yes
Yes
None
None
Yes
Yes
None
None
Yes
Yes
None
None
None
None
None
None
Yes
Yes
ZSI
None
None
None
None
None
None
None
None
G
G
G
G
G
G
G
G
G&I
G&I
G&I
G
G&I
G
G&I
G
Character 7
X
A
B
C
D
E
F
G
K
L
M
N
Q
R
W
Y
Z
1
2
3
5
6
8
9
Rev. 11/13
Data subject to change
without notice
Section 9
Character 8 TU Protection
Character 8
X
1
8
9
A
3
4
5
Fuse Only
I (Switchable)
IG (I Switchable)
IGA (I Switchable)
IGDA (All Switchable)1
GDA (All Switchable)1
G
GA
1G switchable by password only
800A
1200A
1600A
2000A
2500A
3000A
4000A
12 Vdc
24 Vac/24 Vdc
48 Vac/48 Vdc
208 Vac
480 Vac
600 Vac
120 Vac
208 Vac
240 Vac
12 Vdc
24 Vac/24 Vdc
48 Vac/48 Vdc
120 Vac/125 Vdc
208 Vac
240 Vac/250 Vdc
480 Vac
600 Vac
120 Vac
208 Vac
240 Vac
without Lockout
None
None
None
None
None
None
None
None
Character 10
0
H
J
K
L
M
N
P
R
V
W
Y
1
2
3
4
5
6
7
8
S
T
U
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
Character 11
0
1
2
4
5
6
8
9
A
G
H
J
L
240
600
None
240
600
4
4
4
4
4
M
N
R
S
T
Character 12
0
1
2
3
4
5
6
7
8
9
A
B
C
W
X
Y
Hidden On
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
BuyLog Catalog
Character 13
0
1
2
3
4
5
6
8
9
A
B
C
D
E
G
H
J
K
L
M
N
R
S
T
U
V
W
X
9-7
Section 9
Closing Solenoid
None
120 Vac
240 Vac
24 Vdc
48 Vdc
72 Vdc
125 Vdc
None
120 Vac
240 Vac
24 Vdc
48 Vdc
72 Vdc
125 Vdc
Auxiliary Switch
None
4-240V
8-240V
12-240V
4-600V
8-600V
None
4-240V
8-240V
12-240V
4-600V
8-600V
Door Interlock
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Counter
None
None
None
None
None
None
None
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Character 14
8
9
A
B
C
D
E
R
S
T
U
V
W
X
Trimplate
None
None
None
None
None
None
Yes
Yes
Yes
Yes
Yes
Yes
Character 15
0
1
2
3
4
5
8
9
A
B
C
D
THP
08
T
Feed
T = Top
B = Bottom
Fusible Switch
THP = HPC Switch
Frame Size
R = Small Frame (800A-1600A)
C = Large Frame (2000A-4000A)
L = Long Frame (42 4000A w/ GF, Retrofill only)
Switch Rating
08 = 800A
12 = 1200A
16 = 1600A
20 = 2000A
25 = 2500A
25 = 2500A
40 = 4000A
Construction
2 = New Generation
Poles
3 = 3 Pole
Voltage
6 = 600V
9-8
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
SP
AS
240
AB4
HPC Switch
Device Type
AS = Auxiliary switch1
BAA = Bell alarm, alarm only1
BAL = Bell alarm with lockout1
COUNTER = Mechanical counter1
DIL = Defeatable door interlock
E = Electric operator1
K4 = Kirk key lock (4 maximum)1
PBCOVER = Pushbutton cover1
RCS = Remote close solenoid1
ST = Shunt trip
STL = Shunt trip with lockout1
UV = Undervoltage release
R
Extender
R = Field installable kit
Blank = Factory installed
1Device Product Number requires an extender R for field installable kit version only.
NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-9
Section 9
G F
0 8
L W
Char 1-2
Char 3
Char 4 & 5
Char 6 & 7
Char 8
Char 9
Char 10
Char 11
Char 12
Char 13
Char 14
Char 15
Reserved
Sensor Rating
08 = 800A
Reserved
OC and GF Protection Packages
LW = GF Only
Zone Selective Interlocking
X = None
Reserved
Reserved
None
G user selectable
Z+IOC user selectable
Character 8
X
Z
T
800A
1600A
2000A
2500A
3000A
4000A
Note: Use 1600A CT w/ 1200A rating plug for 1200A HPC frame.
800A
1600A
2000A
2500A
3000A
4000A
Character 9
X
1
2
6
8
A
D
E
Character 10
X
9-10
BuyLog Catalog
Character 6 & 7
LZ
S1
S2
S3
S4
S5
LW
LY
Factory
Replacement
www.geindustrial.com
Character 11
F
R
Rev. 11/13
Data subject to change
without notice
Section 9
Application Information
Outlines and Dimensions
Application Information HPC Switches with Integral Ground Fault Protection
Weights are for units with integrally mounted three-phase sensor.
Ampere
Rating
Outline
Drawing
Approx. Shipping
Weight (Lbs.)
Approx. Net
Weight (Lbs.)
139C4219
115
105
2000A
139C4114 sh 2
220
195
2500A
139C4114 sh 3
235
210
3000A
139C4114 sh 3
235
210
TS20FCA
(Optional)
TS25FCA
(Optional)
TS30FCA
(Optional)
1-TS40LFCA
5-TS40FCA
D N
IM O
SW E TE
N
PR IT S : A
IO CH ION PP
R ES S LIC
TO M D A
9
H - 1 2 A AT T I
PC 2 0 N A O
N
F
U
1
F
4
O
S W R . FA O R A N
S
C
E
IT NE E TU HP D
CH W P R C
A
E
ES
G D
E
.
800A
Connectors
Product Number
4000A
139C4114 sh 6
464
540
Data in the table below pertains to Type HPC switches without integral ground devices.
Ampere
Rating
Outline
Drawing
Approx. Shipping
Weight (Lbs.)
Approx. Net
Weight (Lbs.)
800A
139C4219
85
75
2000A
139C4114 sh 2
190
165
2500A
139C4114 sh 3
205
180
3000A
139C4114 sh 3
205
180
4000A
139C4114 sh 6
429
505
Connectors
Product Number
1
TS20FCA
(Optional)
TS25FCA
(Optional)
TS30FCA
(Optional)
1-TS40LFCA
5-TS40FCA
800A
1200A-1600A
2000A
2500A
3000A
4000A
Min Volume
(Cubic
Inches)
8400
11100
28000
28000
30000
54650
23
63
63
172
172
189
C Min Height
(Inches)
2
2
2
2
2
9
28
30
40
40
40
52
F Min to Ground
or Insulation
(Inches)
8.66
8.66
9.38
9.38
9.38
11.12
3.5
3.5
3
3
3
3
Dimension A
Dimension B
Dimension C
Dimension D
Dimension E
Dimension F
800
1200, 1600
2000, 2500, 3000
24.31
26.72
36.00
18.00
18.00
19.25
8.66
8.66
9.38
7.69
7.69
8.25
4.96
4.96
15.56
4000
40.00
22.387
11.12
9.24
12.75 (B)
7.75 (A & C)
18.19
Note: For dimensions of neutral current sensor to be used with integral ground fault switches, page 9-34.
5For complete switch dimensions order outline drawings from application information above.
6For Product Numbers with suffix B (bottom-feed), invert drawing.
7With integral ground fault, overall width is 24 inches.
Switch Dimensions
(For Estimating Only)
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-11
Section 9
Application Information
Outlines and Dimensions
Application Information HPC Switches, New Generation
Ampere
Rating
800A
800A
1200/1600A
1200/1600A
2000A
2000A
2500/3000A
2500/3000A
4000A
4000A
Feed
Outline
Drawing
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
Top
Bottom
10112083P1
10112083P2
10112083P3
10112083P4
10112083P5
10112083P6
10112083P7
10112083P8
10112083P11
10112083P12
Operation
Type
Weight
(lb)
Manual
Electrical
Manual
Electrical
Manual
Electrical
Manual
Electrical
Manual
Electrical
81
90
95
104
110
119
210
219
400
409
Min Volume
(Cubic
Inches)
6062
6495
9380
9380
9380
17347
2
2
2
2
2
9
C Min Height
(Inches)
28
30
40
40
40
52
8.66
8.66
9.38
9.38
9.38
11.12
F Min to Ground
or Insulation
(Inches)
3.5
3.5
3
3
3
3
Note: For dimensions of neutral current sensor to be used with integral ground fault switches,
see outline drawings: 139C5016SH1 & SH2 (TSVG types) and 10112973P1 (SSVG types).
1Ventilating openings can be in alternate location but must provide equivalent ventilating areas.
9-12
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-13
Section 9
Ratings
Vdc
Field Installable
Product Number
Factory Installed
Product Number
24
48
72
125
SPE120R
SPE240R
SPE024R
SPE048R
SPE072R
SPE125R
SPE120
SPE240
SPE024
SPE048
SPE072
SPE125
Electrical Operator
9-14
Ratings
Vdc
Field Installable
Product Number
Factory Installed
Product Number
24
48
72
125
SPRCS120R
SPRCS240R
SPRCS024R
SPRCS048R
SPRCS072R
SPRCS125R
SPRCS120
SPRCS240
SPRCS024
SPRCS048
SPRCS072
SPRCS125
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
24
48
120
208
240
480
600
Ratings
Vdc
Field Installable
Product Number
Factory Installed
Product Number
12
24
48
125
250
SPST012R
SPST024R
SPST048R
SPST120R
SPST208R
SPST240R
SPST480R1
SPST600R1
SPST012
SPST024
SPST048
SPST120
SPST208
SPST240
SPST4801
SPST6001
24
48
120
208
240
480
600
Ratings
Vdc
Field Installable
Product Number
Factory Installed
Product Number
12
24
48
125
250
SPSTL012R
SPSTL024R
SPSTL048R
SPSTL120R
SPSTL208R
SPSTL240R
SPSTL480R1
SPSTL600R1
SPSTL012
SPSTL024
SPSTL048
SPSTL120
SPSTL208
SPSTL240
SPSTL4801
SPSTL6001
Ratings
Vdc
Field Installable
Product Number
Factory Installed
Product Number
12
24
48
125
250
SPUV024ACR
SPUV048ACR
SPUV120ACR
SPUV208ACR
SPUV240ACR
SPUV480ACR1
SPUV600ACR1
SPUV012DCR
SPUV024DCR
SPUV048DCR
SPUV125DCR
SPUV250DCR
SPUV024AC
SPUV048AC
SPUV120AC
SPUV208AC
SPUV240AC
SPUV480AC1
SPUV600AC1
SPUV012DC
SPUV024DC
SPUV048DC
SPUV125DC
SPUV250DC
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-15
Section 9
Factory Installed
Product Number
Field Installable
Product Number1
Trip Accessory
Provided
120
BFSPSTL120AC
BFSPSTL120ACR
SPSTL120
208
BFSPSTL208AC
BFSPSTL208ACR
SPSTL208
240
BFSPSTL240AC
BFSPSTL240ACR
SPSTL240
120
BFSPUV120AC
BFSPUV120ACR
SPUV120AC
208
BFSPUV208AC
BFSPUV208ACR
SPUV208AC
240
BFSPUV240AC
BFSPUV240ACR
SPUV240AC
120
BFSPST120AC
BFSPST120ACR
SPST120
208
BFSPST208AC
BFSPST208ACR
SPST208
240
BFSPS240AC
BFSPST240ACR
SPST240
1For field installable kits only, the Pin wheel style Blown Fuse Detector is not included due to UL accessory listing
requirements.
Source the Boltswitch PW-2 Blown Fuse Detector separately and follow that manufacturers instructions for
mounting and use.
Ratings
Vdc
125-250
125-250
Field Installable
Product Number
SPBAA240R
SPBAA600R2
Factory Installed
Product Number
SPBAA240
SPBAA6002
9-16
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Ratings
Vdc
Field Installable
Product Number
Factory Installed
Product Number
240
600
125-250
125-250
SPBAL240R
SPBAL600R1
SPBAL240
SPBAL6001
Auxiliary Switch
An auxiliary switch signals the HPC switchs primary contact position (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
HPC switch primary contact position. The auxiliary switch operation is independent of
the method by which the HPC switch is opened or closed. The auxiliary switch does not
distinguish between a "tripped" or "open" condition. The auxiliary switch contacts follow
the main HPC switch contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the HPC switch. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125 Vdc and 1/4A at
250 Vdc.
Ratings
Vac
Ratings
Vdc
No. of SPDT
Switch Elements
(Contacts)
Field Installable
Product Number
Factory Installed
Product Number
240
240
240
600
600
125-250
125-250
125-250
125-250
125-250
4
8
12
4
8
SPAS240AB4R
SPAS240AB8R
SPAS240AB12R
SPAS600AB4R1
SPAS600AB8R1
SPAS240AB4
SPAS240AB8
SPAS240AB12
SPAS600AB41
SPAS600AB81
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-17
Section 9
Factory Installed
Product Number
SPCOUNTERR
SPCOUNTER
Factory Installed
Product Number
SPPBCOVERR
SPPBCOVER
Factory Installed
Product Number
SPPBNONR
SPPBNON
Maintenance/Repair Parts
Description
Product Number
SPBIICOVER1
SPPBRONR
9-18
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Number of Locks
SPK4
SPK4
SPK4
SPK4
1
2
3
4
KFN000011
KFN000021
KFN000031
KFN000041
Superior
Product Number
S105827Y
S105828Y
S105829Y
S105827-4Y
Number of
Key Locks
Field Installed
Product Number
Factory Installed
Product Number
All
1 to 4
SPK4R
SPK4
Door Interlock
The door interlock provides interlocking of the switch compartments hinged door so
that the switch must be in the "OFF" position before the door can be opened. The door
interlock is defeatable with a small tool to allow authorized access.
Field Installed
Product Number
Factory Installed
Product Number
SPDILR
SPDIL
Door Interlock
Padlocking provisions are standard on all new generation HPC switches. When the
switch is in the open position, and the padlock hasp is raised at least 1/4", the switch
cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
with 1/4" to 3/8" diameter shanks.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-19
Section 9
Accessories
UL Listed
Adapter Kits
(Accepts either lugs, bus, or Anderson VCEL VersaCrimp)
For Line or Load end of 3-pole switch.
Product
Number
Ampere Rating
800A
1200A
1600A
TPLUGA16
Field installed only. Kits consist of lugs and hardware for direct
mounting to switch terminal straps (multiple-hole tang lugs) or lugs
for mounting to 800 ampere terminal adapter kit. Order three kits
for three-pole line or load end. For 1600-ampere, copper conductors must be used.
800A
1200A, 1600A
1200A, 1600A
Wire Range
Cu/Al
800A
800A
3
6
THPCLUGA08
Ampere Rating
Accessory
Type
Lug Kit Line
& Lug Kit Load
Lug Kit Line
Lug Kit Load
Wire Range
Cu/Al
Product
Number
(3) 300-750
THPCLUG308
TPLUG408
THPCLUG408
Ampere Rating
Product
Number
TPLUG106
TPLUG108
Trimplate
Factory Installed
Product Number
Field Installable
Product Number
SPTRIMPLATE
SPTRIMPLATER
Product
Number
6
7
9
11
TSLUG20
TSLUG25
TSLUG30
TSLUG40
Product
Number
800
1200-1600
2000
2500
3000
THPC08FCA1
TP16FCA
TS20FCA
TS25FCA
TS30FCA
TS40FCA2
TS40LFCA3
4000
1For vertical bussing only.
2For load terminals and left/right line terminals.
3For center pole, line terminal.
9-20
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
HPC Switch
Sensor Rating
(Amperes)
Neutral Sensor
Rating or Tap
Settings (Amperes)
Product
Number
200
400
400
800
1000
1000
1600
1600
2000
1000
1000
1000
1000
2000
2500
3000
4000
200
400/200
600/3002
800/400
800/4002
1000/500
1200/6002
1600/1000
2000/1000
800/4002
1000/500
1200/6002
1600/10002
2000/1200
2500/1800
3000/2400
4000/3000
TSVG302
TSVG304A
TSVG306A
TSVG308A
TSVG808A
TSVG810A
TSVG812A
TSVG816A
TSVG820A
TSVG808A
TSVG810A
TSVG812A
TSVG816A
TSVG820A
TSVG825A
TSVG830A
TSVG940A
800
800-1600
1600
2000
3000
4000
1Match neutral current sensor rating (or tap setting) to new HPC switch
sensor rating.
2For use with multiple source ground fault protection schemes. Rating does
HPC Switch
Sensor Rating
(Amperes)
Neutral Sensor
Rating or Tap
Settings (Amperes)
800
12003
16003
1600
2000
2500
3000
4000
800/400
2000/1200
1600/1000
1600/1000
2000/12003
2500/1800
4000/3000
4000/3000
800
1200
1600
2000
2500
3000
4000
Product
Number of
Window Sensor
Inside
Diameter
(inches)
SSVG808W
SSVG820W
SSVG816W
SSVG816W
SSVG820W
SSVG825W
SSVG940W
SSVG940W
4.25
5.63
5.63
5.63
5.63
5.63
6.50
6.50
1Match neutral current sensor rating (or tap setting) to new HPC Switch
sensor rating.
3At time of initial product release, the 1200A new HPC Switch was using 1600A
installed sensors and a 1200A rating plug. Later models may or may not use
1200A phase sensors. Match Neutral sensor tap to HPC sensor rating.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-21
Section 9
Reference Publications
Auxiliary Switch Module
Bell Alarm Alarm Only
Door Interlock
Lugs & Adapters for 8002000 A Frames
Bell Alarm with Lockout
Key Interlock Mounting Provision
Mechanical Counter
Motor Operator Mechanism
Push Button Cover
Remote Close
Shunt Trip and Shunt Trip with Lockout (except 480 and 600 Vac)
Shunt Trip and Shunt Trip with Lockout, 480 & 600 Vac
Undervoltage Release (except 480 and 600 Vac)
Undervoltage Release, 480 & 600 Vac
Instructions, HPC Heat Sink Installation
Instructions, HPC Blown Fuse Protector
EntelliGuard TU Trip Unit
HPC Switches, New Generation, Users Guide
Time Current Curves HPC Switches, New Generation, Ground Fault
Time Current Curves HPC Switches,
New Generation, Adjustable Selective Instantaneous Trip,
Reduced Energy Let-Through (RELT)
HPC Switches, New Generation, Instantaneous Protection Guide
9-22
BuyLog Catalog
GEH6274
GEH6275
GEH6276
GEH4546
GEH6278
GEH6279
GEH6280
GEH6281
GEH6282
GEH6283
GEH6284
GEH6519
GEH6285
GEH6520
DEH41694
DEH41695
DEH4567
DEH41689
DES121
DES-122
DEE-715
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Product Description
QMR and QMW switches (30-200 amperes), fuse and no-fuse kits
are UL Recognized Components, File E-36152, and UL Recognized
to Canadian safety requirements under the Component Recognition
Program of Underwriters Laboratories Inc.
The 30-200 ampere fusible switches are UL Recognized for use
on circuits capable of delivering not more than 200,000 rms
symmetrical amperes at 240 or 600Vac when fused with Class R
rated size fuses. Refer to the table 7-3 for the appropriate Class R
Fusing Kit. They are suitable for use with Type STDA flange handles
and variable depth operating mechanisms on page 9-28.
Ampere Rating
Product Number
30A
60A
100A
200A
30A
60A
100A
200A
950
1700
1800
3600
420
900
1700
3400
THMC311
THMC321
THMC331
THMC34
THMS311
THMS321
THMS331
THMS34
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-23
Section 9
Description
of Kit
HP Rating,
AC, 3-Phase,
NEC Std.
Fuse @ 240Vac
HP Rating,
AC, 3-Phase,
NEC Std.
Fuse @ 480Vac
HP Rating,
AC, 3-Phase,
NEC Std.
Fuse @ 600Vac
HP Rating,
AC, 3-Phase,
Time-Delay
Fuse @ 240Vac
HP Rating,
AC, 3-Phase,
Time-Delay
Fuse @ 480Vac
HP Rating,
AC, 3-Phase,
Time-Delay
Fuse @ 600Vac
HP Rating,
125Vdc
HP Rating,
250Vdc
3
5
10
5
15
25
7.5
20
30
7.5
20
30
60
7.5
15
30
20
40
60
125
15
40
60
25
50
75
150
20
50
75
3
5
3
5
3
5
5
10
20
40
5
10
5
10
20
25
25
50
50
60
60
60
125
150
40
50
100
125
No Fuse
No Fuse
No Fuse
No Fuse
30A, 240Vac/250Vdc
60A, 240Vac/250Vdc
30A, 600Vac
60A, 600Vac
100A, 240Vac/250Vdc
100A, 600Vac
200 A, 600Vac
200A, 240Vac/250Vdc
200A, 600Vac
400A, 600Vac
Fuse and No-Fuse Kits (Includes load block, clips, and lugs)
Product
Number
Description of Kit
Switch
Product Number
Fuse Type
No. of Poles
THMC31002
No Fuse
THMC31 or THMS31
No Fuse
THMC3200
THMC3300
THMC3400
THMC31211
No Fuse
No Fuse
No Fuse
30A, 240Vac/250Vdc
THMC32 or THMS32
THMC33 or THMS33
THMC34 or THMS34
THMC31 or THMS31
No Fuse
No Fuse
No Fuse
NEC Standard
3
3
3
3
THMC32221
60A, 240Vac/250Vdc
THMC31 or THMS31
NEC Standard
THMC31611
30A, 600Vac
HMC31 or THMS31
60A, 600Vac
THMC31 or THMS31
THMC3363
100A, 240Vac/250Vdc
100A, 600Vac
200A, 600Vac
THMC32 or THMS32
NEC Standard
and Class J
NEC Standard
and Class J
NEC Standard
and Class J
NEC Standard
and Class J
NEC Standard
and Class J
NEC Standard
and Class J
THMC32621
THMC3364
THMC3464
THMC3465
200A, 240Vac/250Vdc
200A, 600Vac
400A, 600Vac
THMC33 or THMS33
THMC34 or THMS34
THMC34 or THMS34
CU 14-0 AL 12-0
No-fuse ratings indicate switch capability as permitted by UL 508 (Ind. Cont. Equip.), additional hp ratings correspond to commercially available fuses.
For DC use outer poles.
1Can be used for one-step underfusing for next higher current-rated disconnect.
2Maximum UL listing 20 hp. at 600V.
9-24
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Assembled with Lugs, Fuse Clips and Handle Operators Horsepower Ratings
Duty Type
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Heavy Duty QMR
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Premium Duty QMW
Disconnect Switch
Rating (Amperes)
Max. HP Rating
@ 240Vac 3-Phase
Max. HP Rating
@ 480Vac 3-Phase
Max. HP Rating
@ 600Vac 3-Phase
Max. HP Rating
@ 250 Vdc
Product Number
30A
30A
30A
60A
60A
60A
100A
100A
200A
200A
400A
400A
400A
400A
400A
400A
400A
400A
600A
600A
600A
600A
600A
600A
600A
600A
600A
600A
600A
600A
30A
30A
30A
60A
60A
60A
100A
100A
200A
200A
7.5
7.5
7.5
20
15
30
30
60
60
125
125
125
125
125
125
125
125
200
200
200
200
200
200
200
200
200
200
200
200
7.5
7.5
7.5
20
15
30
30
60
60
20
15
40
30
60
60
125
125
250
250
250
250
250
250
400
400
400
400
400
400
400
400
400
400
20
15
40
30
60
60
125
125
20
20
50
50
75
75
150
150
350
350
350
350
350
350
500
500
500
500
500
500
500
500
500
500
20
20
50
50
75
75
150
150
5
5
5
10
10
10
20
20
40
40
50
50
50
50
50
50
50
50
5
5
5
10
10
10
20
20
40
40
THMR3100
THMR3121
THMR3161
THMR3200
THMR3222
THMR3262
THMR3300
THMR33631
THMR3400
THMR34641
THMA35NF
THMA3525
THMA3565
THMA35J52
THMRB35NF
THMRB3525
THMRB3565
THMRB35J52
THMA36NF
THMA3665
THMA3626
THMA36663
THMA36J62
THMA36L74
THMRB36NF
THMRB3665
THMRB3626
THMRB36663
THMRB36J62
THMRB36L74
THMCR3100
THMCR3121
THMCR3161
THMCR3200
THMCR3222
THMCR3262
THMCR3300
THMCR3363
THMCR3400
THMCR3464
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4; Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-25
Section 9
Handle Style
30A
No Fuse
No Fuse
30A
30
30A
30
60A
60A
60A
100A
100A
200A
200A
400A
No Fuse
60
No Fuse
100
No Fuse
200
No Fuse
No Fuse
60
No Fuse
100
No Fuse
200
No Fuse
400A
400
TDM Adjustable
Shaft Handle
400A
400
TDM Adjustable
Shaft Handle
400A
400
TDM Adjustable
Shaft Handle
400A
No Fuse
No Fuse
400A
400
400A
400
400A
400
600A
600A
No Fuse
400
No Fuse
400
THMA36NF
THMA3665
600A
600
THMA3626
600A
600
THMA36663
600A
600
THMA36J62
600A
800
THMA36L74
600A
600A
600A
600A
600A
600A
No Fuse
400
600
No Fuse
400
600
600
800
Wire Keeper,
Term. for #14-8 Cu
Wire Keeper,
Term. for #14-8 Cu
Wire Keeper,
Term. for #14-8 Cu
CU 14-2 AL 12-2
CU 14-2 AL 12-2
CU 14-2 AL 12-2
10-1/0 Cu/Al
10-1/0 Cu/Al
6-250 kcmil Cu/Al
6-250 kcmil Cu/Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/A
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(1) # 22-600 kcmil Cu/Al
or (2) 1/0-3/0 Cu or
(2) 1/0-250 kcmil Al
(2) # 4-600 kcmil Cu/Al
(2) # 4-600 kcmil Cu/Al
THMRB36NF
THMRB3665
THMRB3626
THMRB36663
THMRB36J62
THMRB36L74
Duty Type
Product Number
THMR3100
THMR3121
THMR3161
THMR3200
THMR3222
THMR3262
THMR3300
THMR33631
THMR3400
THMR34641
THMA35NF
THMA3525
THMA3565
THMA35J52
THMRB35NF
THMRB3525
THMRB3565
THMRB35J52
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4. Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.
9-26
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Assembled Switches with Lugs, Fuse Clips and Handle Operators (Continued)
Ampere
Rating
Handle Style
Product Number
30A
No Fuse
No Fuse
THMCR3100
30A
30
30A
30
60A
60A
60A
100A
100A
200A
200A
No Fuse
60
No Fuse
Wire Keeper,
Term. for #14-8 Cu
Wire Keeper,
Term. for #14-8 Cu
Wire Keeper,
Term. for #14-8 Cu
CU 14-2 AL 12-2
CU 14-2 AL 12-2
CU 14-2 AL 12-2
10-1/0 Cu/Al
10-1/0 Cu/Al
6-250 kcmil Cu/Al
6-250 kcmil Cu/Al
Duty Type
60
No Fuse
100
No Fuse
200
No Fuse
100
No Fuse
200
THMCR3121
THMCR3161
THMCR3200
THMCR3222
THMCR3262
THMCR3300
THMCR3363
THMCR3400
THMCR3464
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
Order Door Ring Interlock Kit343L483G4. Gasket Kit792A489G3.
400 and 600 Ampere switches with TDM handle have pendulum operation.
400 and 600 Ampere QMR units are UL Recognized on 100,000 Ampere rms circuits when fused with rated size Class J or R fuses.
1Field convertible to 250 Volt fusing.
2Supplied with Class J fuse clips.
3600 Ampere, 600 Volt Class H fused to Class J fusing. Order kit Product Number THJ6. One kit required per switch. 400 Ampere units can be field converted by moving the
fuse block toward the switch.
4Supplied with Class L fuse clips.
Field Installed
Product Number
TPBRK12A
TPBRK16A
TPBRK22A
TPBRK26A
TPBRK36A
TRK46A
TPBRK56A5
TRK66A5
5Not suitable for use with individual components shown on pages 9-23 and 9-24.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-27
Section 9
Handle Operators
Product Description
Type STDA Flange Handles and Variable Depth Operating
Mechanisms For Use With QMR/QMW 30-200A Disconnects
Designed to meet automotive duty specifications.
NEMA 12/13 and 4/4X, UL Recognized Components, File E57253, and UL Recognized to Canadian safety requirements
under the Component Recognition Program of Underwriters
Laboratories Inc.
For right- or left-hand flange mountingfield convertible.
Mounting dimensions to fit standard flange enclosures
8"-24" deep.
Drilling templates and detailed installation instructions.
Flange Handle Selection
Product Number STDA1 (6-inch) and STDA2 (10-inch) flange handles are interchangeable. While all operating mechanisms can be
easily operated with the 6-inch STDA1 handle, the 10-inch STDA2
may be used to obtain lower operating force and/or to provide a
proportionally larger handle on large enclosures.
Flange Handle, STDA1
Construction Details
Flange Handles
Flange Handles
Enclosure Type
NEMA Type 12/13
NEMA Type 12/13
NEMA Type 4/4X
NEMA Type 4/4X
Nominal Length
(Inches)
Installation Instruction
Number
Drilling Template
Number
Product
Number
6
10
6
10
GEH-5314
GEH-5314
GEH-5314
GEH-5314
GEH-5314
GEH-5314
GEH-5314
GEH-5314
STDA1
STDA2
STDA1X
STDA2X
QMR/QMW/
Flange Handle Product Number
Operating Mechanism
Installation Instruction No.
Product
Number
STDA1, 1X or STDA2, 2X
STDA1, 1X or STDA2, 2X
GEH-5315
GEH-5315
TDOM1A
TDOM1B
STDA1, 1X or STDA2, 2X
GEH-5316
TDOM2
Select individual QMR or QMW disconnect and fuse or no-fuse kit from page 9-24.
9-28
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Contacts
SPDT
SPDT
DPDT
DPDT
When TDA
handle is on
Right Flange
When TDA
handle is on
Left Flange
Product
Number
TDAS1L1
TDAS1R1
TDAS1L2
TDAS1R2
120
40
15
30
3
AC Voltage
240
480
20
20
10
6
15
8
1.5
1
600
8
5
6
0.8
0.2
0.1
TDSR
Product Number
Rev. 11/13
Data subject to change
without notice
TDS1
www.geindustrial.com
Description
NEMA 12/13
two-point
interlocking
door hardware kit
NEMA 4/4X
two-point
interlocking
door hardware kit
Third-point
latch kit for above
NEMA 12/13
two-point
interlocking
door hardware kit
NEMA 4/4X
two-point
interlocking
door hardware kit
Third-point
latch kit for above
Accessory Type
Product Number
TDV1
TDV1X
TDV3
TDV1L
TDV1LX
TDV3L
Agency Certifications
STDA accessories are UL Recognized Components, File E-36152,
and UL Recognized to Canadian safety requirements under the
Component Recognition Program of Underwriters Laboratories Inc.
Reference Publications
Door Hardware
Auxiliary Contact Kit
Flange Stiffener Kit or Extended-Length Drive Rod
Extended Drive Stud
Operating Mechanism:
TDOM1A through TDOM1B
TDOM2
BuyLog Catalog
GEH-5322
GEH-5323
GEH-5324
GEH-5325
GEH-5315
GEH-5316
9-29
Section 9
Overpack Kits
QMW disconnect switch, fuse kit with copper lugs, operating mechanism and STDA1 flange handle packed in a single carton.
QMW with Copper Lugs for Copper Cables Only and Class R Rejection Clips for Class R Fusing
Ampere
Rating
Fuse Clip
Rating (Ampere)
System
Voltage
Product
Number
30A
30A
30A
60A
60A
60A
100A
No Fuse
30
30
No Fuse
60
60
No Fuse
THMC3200CL
THMC3121CLR
THMC3161CLR
THMC3200CL
THMC3222CLR
THMC3262CLR
THMC3300CL
TDOM1A
TDOM1A
TDOM1B
TDOM1A
TDOM1B
TDOM1B
TDOM1A
STDAD3NF
STDAD332R
STDAD336R
STDAD6NF
STDAD662R
STDAD666R
STDAD1NF
100A
200A
100
No Fuse
THMC3363CLR
THMC3400CL
TDOM1B
TDOM2
STDAD100R
STDAD2NF
200A
200
No Fuse
250Vdc
600Vac
No Fuse
250Vdc
600Vac
No Fuse
250Vdc
600Vac
No Fuse
250Vdc
600Vac
THMC3464CLR
TDOM2
STDAD200R
QMW with Copper Lugs for Copper Cables Only and Class J Clips for Class J Fusing
Ampere
Rating
30A
30A
60A
60A
100A
100A
200A
200A
9-30
Fuse Clip
Rating (Ampere)
System
Voltage
Product
Number
30
60
60
100
100
200
200
400
600Vac
600Vac
600Vac
600Vac
600Vac
600Vac
600Vac
600Vac
THMC3161CL
THMC3262CL
THMC3262CL
THMC3363CL
THMC3363CL
THMC3364CL
THMC3464CL
THMC3465
TDOM1JA
TDOM1JB
TDOM1JB
TDOM1JA
TDOM1JA
TDOM1A
TDOM2
TDOM2
STDAD336J
STDAD3362J
STDAD666J
STDAD6663J
STDAD106J
STDAD1064J
STDAD206J
STDAD2065J
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
General-Duty HCI
Factory Assembled Fuse Clips
TDM Door-Mounted Handle
240, 480, 600 Vac, 250 Vdc
Product Description
These 30-200 ampere disconnect switches are complete with
fuse clips and line/load lugs, both factory assembled, and overpacked NEMA 12 handle operators (TDM). They are listed in UL
Recognized Component Index (WHTY2) for mounting in a vertical
position, line side up. They provide 600 volt industrial control electrical spacings and are described in UL File E-36152. For units with
600 Volt enclosed switch spacings, select individual components
from pages 9-32 to 9-35. They are suitable for use on circuits with
available short-circuit currents to 10,000 amperes.
Assembled Switches with Lugs, Fuse Clips, Operating Shafts and Handle Operators Max. Horsepower Ratings
Disconnect
Switch (Amperes)
Max. HP Rating1
@ 240Vac 3-Phase
Max. HP Rating1
@ 480Vac 3-Phase
Max. HP Rating1
@ 600Vac 3-Phase
Max. HP Rating
@ 250Vdc
Product
Number
7.5
7.5
15
15
30
30
60
60
15
20
20
50
50
75
75
100
100
5
5
5
10
10
10
20
20
20
40
40
40
THC3100AFC
THC3121AFC
THC3161AFC
THC3200AFC
THC3222AFC
THC3262AFC
THC3300AFC
THC3323AFC
THC3363AFC
THC3400AFC
THC3424AFC
THC3464AFC
30A
30A
30A
60A
60A
60A
100A
100A
100A
200A
200A
200A
15
30
30
60
60
100
100
Assembled Switches with Lugs, Fuse Clips, Operating Shafts and Handle Operators2
Ampere
Rating
Lug Wire
Size
Product
Number
No-Fuse600V
30
N/A
No-Fuse600V
60
N/A
No-Fuse600V
100
N/A
No-Fuse600V
200
N/A
No-Fuse600V
N/A
30
No-Fuse600V
N/A
60
No-Fuse600V
N/A
100
No-Fuse600V
N/A
200
#14-8 CU
#14-8 CU
#14-8 CU
#14-2 CU
#14-2 CU
#12-2 AL
#14 1/0 CU-AL
#14 1/0 CU-AL
#14 1/0 CU-AL
#6-250 kcmil CU-AL
#6-250 kcmil CU-AL
#6-250 kcmil CU-AL
5 1/16-7 15/16
5 1/16-7 15/16
5 1/16-7 15/16
5 13/16-9 1/4 (5 9/16)
5 13/16-9 1/4 (5 9/16)
5 13/16-9 1/4 (5 9/16)
7 1/4-9 1/8 (6 7/16)4
7 1/4-9 1/8 (6 7/16)4
7 1/4-9 1/8 (6 7/16)4
9 1/4-14 3/4
9 1/4-14 3/4
9 1/4-14 3/4
THC3100AFC
THC3121AFC
THC3161AFC
THC3200AFC
THC3222AFC
THC3262AFC
THC3300AFC
THC3323AFC
THC3363AFC
THC3400AFC
THC3424AFC
THC3464AFC
30A
30A
30A
60A
60A
60A
100A
100A
100A
200A
200A
200A
1Maximum hp ratings for fusible units may require fuses with time-delay characteristics.
2For switch with under- or over-fusing, use individual components on pages 9-32 to 9-35.
3Handle and shaft provided are pendulum type. If up-down operation is required, order individual components.
4Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-31
Section 9
General-Duty HCl
Individual Components
30-200 Amperes
240, 480, 600 Vac, 250 Vdc
Basic Switch
Ampere Rating
No. of Poles
30A
30A
60A
60A
100A
100A
200A
200A
Product Number
THC311
THC31S2,4
THC323
THC32S2
THC331
THC33S2
THC341
THC34S2
3
3
3
3
3
3
3
3
Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15
ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index
(WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuseclip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index
(WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical
spacingsrequires cutting handle shaft.
1For basic switches with UL 600 Volt industrial control and 250 Volt enclosed switch
Ampere
Rating
Shaft
Length
Shaft
Operation
Enclosure
Type
30A
Standard
Up-Down
5 1/16-7 15/16
THC1
30A
Standard
Pendulum
5 1/16-7 15/16
THC1P
30A
60A
30A
60A
60A
Long
Up-Down
11 1/8 (5 9/16)-14
THC1L
Long
Pendulum
11 1/8 (5 9/16)-14
THC1PL
Standard
Up-Down
THC2
60A
Standard
Pendulum
THC2P
100A
Standard
Up-Down
THC3
100A
Standard
Pendulum
THC3P
100A
Long
Up-Down
12 1/8 (6 7/16)-14
THC3L
100A
Long
Pendulum
12 1/8 (6 7/16)-14
THC3PL
200A
Standard
Up-Down
9 1/4-14 3/4
THC4
200A
Standard
Pendulum
9 1/4-14 3/4
THC4P
200A
Long
Up-Down
14 11/32 (9 1/4)-20
THC4L
200A
Long
Pendulum
14 11/32 (9 1/4)-20
THC4PL
30A
60A
100A
THCH1
TDM Handles
200A
TDM Handles
NEMA Type 1
NEMA Type 3R
NEMA Type 12
NEMA Type 12K
NEMA Type 1
NEMA Type 3R
NEMA Type12
NEMA Type12K
NEMA Type 4/4X
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
Adjustable Operating
Shafts
TDM Handles
Product
Number
THCH4
THCH455
5Includes interlock for use only with 30-60 ampere HCI pendulum-operated shaft.
9-32
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
HP Rating, AC,
3-Phase, NEC
Standard @ 240Vac
HP Rating, AC,
3-Phase, NEC
Standard @ 480Vac
HP Rating, AC,
3-Phase,NEC
Standard @ 600Vac
HP Rating, AC,
3-Phase, Time-Delay
Fuse @ 240Vac
HP Rating, AC,
3-Phase, Time-Delay
Fuse @ 480Vac
HP Rating, AC,
3-Phase, Time-Delay
Fuse @ 600Vac
HP Rating,
250Vdc
Product
Number
7.5
7.5
15
7.5
15
25
15
25
50
5
5
15
15
15
15
25
25
15
25
25
50
50
25
25
50
50
100
100
7.5
7.5
15
15
7.5
15
15
30
30
15
30
30
60
60
30
30
60
60
100
100
7.5
7.5
15
15
30
30
60
60
15
15
15
30
30
30
60
60
60
100
100
100
20
20
20
50
50
50
75
75
75
100
100
100
5
5
10
10
20
20
40
40
THC31001,3
THC3121
THC3161
THC31J1
THC3122
THC3162
THC31J2
THC32002
THC32212
THC32612
THC32222
THC32622
THC32J22
THC32232
THC32632
THC32J32
THC3300
THC3322
THC3362
THC3323
THC3363
THC33J3
THC3324
THC3364
THC33J4
THC3400
THC3423
THC3463
THC34J3
THC3424
THC3464
THC34J4
THC3425
THC3465
THC34J5
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
HP Rating, AC,
3-Phase, NEC
Standard @ 240Vac
HP Rating, AC,
3-Phase, NEC
Standard @ 480Vac
HP Rating, AC,
3-Phase, NEC
Standard @ 600Vac
HP Rating, AC,
3-Phase, Time-Delay
Fuse @ 240Vac
HP Rating, AC,
3-Phase, Time-Delay
Fuse @ 480Vac
HP Rating, AC,
3-Phase, Time-Delay
Fuse @ 600Vac
HP Rating,
250Vdc
3
3
7.5
7.5
5
5
15
15
25
25
50
50
7.5
7.5
15
15
30
30
60
60
7.5
15
30
60
15
15
15
30
30
30
60
60
60
100
100
100
20
20
20
50
50
50
75
75
75
100
100
100
5
5
5
10
10
10
20
40
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
Product
Number
THC31S611,3
THC31SJ11,3
THC31001,3
THC32S62
THC32SJ2
THC32002
THC3363
THC33J3
THC3300
THC3464
THC34J4
THC3400
Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15 ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuse-clip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.
1Suitable for 25 hp @ 600 V but not UL listed.
2Basic switch with UL 600 Volt industrial control spacings only.
3For 30 ampere switch with 600 Volt enclosed switch spacing and 60 ampere terminals, order Product Number THC31SSE.
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-33
Section 9
Fuse Type
Product Number
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
THC31S
THC31
THC31
THC31
THC31
THC31
THC31
THC32S
THC32
THC32
THC32
THC32
THC32
THC32
THC32
THC32
THC33S
THC33
THC33
THC33
THC33S
THC33S
THC33
THC33
THC33
THC34S
THC34
THC34
THC34
THC34
THC34
THC34
THC34
THC34
THC34
No Fuse
NEC Standard
NEC Standard
Class J
NEC Standard
NEC Standard
Class J
No Fuse
NEC Standard
NEC Standard
NEC Standard
NEC Standard
Class J
NEC Standard
NEC Standard
Class J
No Fuse
NEC Standard
NEC Standard
NEC Standard
NEC Standard
Class J
NEC Standard
NEC Standard
Class J
No Fuse
NEC Standard
NEC Standard
Class J
NEC Standard
NEC Standard
Class J
NEC Standard
NEC Standard
Class J
No Fuse600
30A, 240Vac/250Vdc
30A, 600Vac
30A, 600Vac
60A, 240Vac/250Vdc
60A, 600Vac
60A, 600Vac
No Fuse600
30A, 240Vac/250Vdc
30A, 600Vac
60A, 240Vac/250Vdc
60A, 600Vac
60A, 600Vac
100A, 240Vac/250Vdc
100A, 600Vac
100A, 600Vac
No Fuse600
60A, 240Vac/250Vdc
60A, 600Vac
100A, 240Vac/250Vdc
100A, 600Vac
100A, 600Vac
200A, 240Vac/250Vdc
200A, 600Vac
200A, 600Vac
No Fuse600
100A, 240Vac/250Vdc
100A, 600Vac
100A, 600Vac
200A, 240Vac/250Vdc
200A, 600Vac
200A, 600Vac
400A, 240Vac/250Vdc
400A, 600Vac
400A, 600Vac
THC31001,3
THC3121
THC3161
THC31J1
THC3122
THC3162
THC31J2
THC32002
THC32212
THC32612
THC32222
THC32622
THC32J22
THC32232
THC32632
THC32J32
THC3300
THC3322
THC3362
THC3323
THC3363
THC33J3
THC3324
THC3364
THC33J4
THC3400
THC3423
THC3463
THC34J3
THC3424
THC3464
THC34J4
THC3425
THC3465
THC34J5
Fuse Type
Product Number
30 Ampere 3-Pole
30 Ampere 3-Pole
30 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
60 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
100 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
200 Ampere 3-Pole
THC31S
THC31S
THC31S
THC32S
THC32S
THC32S
THC33S
THC33S
THC33S
THC34
THC34
THC34S
NEC Standard
Class J
No Fuse
NEC Standard
Class J
No Fuse
NEC Standard
Class J
No Fuse
NEC Standard
Class J
No Fuse
30A, 600Vac
30A, 600Vac
No Fuse600
60A, 600Vac
60A, 600Vac
No Fuse600
100A, 600Vac
100A, 600Vac
No Fuse600
200A, 600Vac
200A, 600Vac
No Fuse600
THC31S611,3
THC31SJ11,3
THC31001,3
THC32S62
THC32SJ2
THC32002
THC3363
THC33J3
THC3300
THC3464
THC34J4
THC3400
Auxiliary switch (SPDT) for HCI rated .5 ampere at 125Vdc, .25 ampere at 250Vdc, 15 ampere at 480Vac. Product Number 343L296G2.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Line shield included with THC31 and THC31S. All other line shields included with fuse-clip or no-fuse kits.
For Two-pole applicationsUse two poles of three-pole switch.
HCI switches, fuse and no-fuse kits, are listed in UL Recognized Component Index (WHTY2) for mounting in a vertical position, line side up. UL File E-36152.
Inside enclosure depth may be reduced to these depths while maintaining electrical spacingsrequires cutting handle shaft.
1Suitable for 25 hp @ 600 V but not UL listed.
2Basic switch with UL 600 Volt industrial control spacings only.
3For 30 ampere switch with 600 Volt enclosed switch spacing and 60 ampere terminals, order Product Number THC31SSE.
9-34
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
TDR Handle
Ampere Rating
Product Number
V1
V2
H1
H1
THMR1B
THMR2B
THMR1HB
THMR2HB
SEFRDRCK
SEFRGSK
Ampere Rating
Product Number
Auxiliary Switch
Auxiliary Switch
100
200
AS1
AS2
343L492G1
343L492G2
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-35
Section 9
FD130CC
Product
Number
FD130CC
FD130J
FD130NF
FD160J
FD160NF
FD1100J
FD1100NF
FD1200J
FD1200NF
Maximum HP,
3-Phase
AC @ 240Vac,
60Hz,
Time Delay
Maximum HP,
3-Phase
AC @ 480Vac,
60Hz,
Time Delay
Maximum HP,
3-Phase
AC @ 600Vac,
60Hz,
Time Delay
Maximum HP,
Single-Phase
AC @ 120Vac,
60Hz,
Time Delay
Maximum HP,
Single-Phase
AC @ 240Vac,
60Hz,
Time Delay
Maximum
HP,
DC @ 125Vdc,
Time Delay
Maximum
HP,
DC @ 250Vdc,
Time Delay
5
7.5
7.5
15
15
30
30
60
60
10
15
15
30
30
60
60
125
125
10
20
20
50
50
75
75
150
150
0.75
2
2
3
3
2
3
3
10
10
15
15
25
25
2
3
3
5
5
3
5
5
10
10
20
20
40
40
FD130J
5
3
3
7.5
7.5
15
15
25
25
10
5
5
15
15
25
25
50
50
10
7.5
7.5
15
15
30
30
60
60
0.75
0.5
0.5
1.5
1.5
2
1.5
1.5
3
3
7.5
7.5
15
15
2
2
2
5
5
FD130NF
3
5
5
5
5
20
20
40
40
FD160J
Fuse
Type
Maximum Fuse
Cartridge Size
Maximum
Voltage
Maximum Available
Fault Current
Product
Number
30A
Class CC HRCI-MISC
30 A
600Vac/250Vac
100 kA
FD130CC2
30A
30A
60A
60A
100A
100A
200A
200A
Class J HRCI-J
Non-Fused
Class J HRCI-J
Non-Fused
Class J HRCI-J
Non-Fused
Class J HRCI-J
Non-Fused
30 A
30 A
60 A
60 A
100
Non-Fused
200
Non-Fused
600Vac/250Vac
600Vac/250Vac
600Vac/250Vac
600Vac/250Vac
600Vac/250Vac
600Vac/250Vac
600Vac/250Vac
600Vac/250Vac
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
FD130J
FD130NF1,2
FD160J
FD160NF1,2
FD1100J
FD1100NF1,2
FD1200J
FD1200NF1,2
FD160NF
1Non-fused disconnect switches must be used with separately installed UL Listed class J, CC or T fuses; or CSA
Mechanical Specifications3
Product
Number
FD130CC
FD130J
FD130NF
FD160J
FD160NF1
FD1100J
FD1100NF
FD1200J
FD1200NF
27
27
27
45
45
107
107
239
239
#14 - #8
#14 - #8
#14 - #8
#14 - #4
#14 - #4
#14 - #2
#14 - #2
#6 - 250kcmil
#6 - 250kcmil
#14 - #12
#14 - #12
#14 - #12
#14 - #12
#14 - #12
#14 - #12
#14 - #12
#14 - #12
#14 - #12
Maximum Number of
Auxiliary Circuits
4
4
4
4
4
4
4
4
4
9-36
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Color
Comments
Product Number
FD130 or FD160
Black
FD1HA4XB
FD130 or FD160
Red/Yellow
NEMA 4, 4X,
with defeat to enable
panel entry while power on.
NEMA 4, 4X,
with defeat to enable
panel entry while power on.
NEMA 3R,
simple on/off
pistol grip handle
NEMA 3R,
simple on/off
pistol grip handle
NEMA 3R,
on/off with lock-out
tag-out pistol grip handle
NEMA 3R,
on/off with lock-out
tag-out pistol grip handle
NEMA 3R,
on/off with lock-out
tag-out and defeatable
pistol grip handle
NEMA 3R,
on/off with lock-out
tag-out and defeatable
pistol grip handle
FD1100 or FD1200
Black
FD1100 or FD1200
Red/Yellow
FD1100 or FD1200
Black
FD1100 or FD1200
Red/Yellow
FD1100 or FD1200
Black
FD1100 or FD1200
Red/Yellow
FD1HA4XRY
FD11HA1B
FD11HA1RY
FD11HA4RY
FD11HA3B
FD11HA3RY
Operating Shafts
Switch Type
FD130 or
FD160
FD130 or
FD160
FD1100 or
FD1200
FD1100 or
FD1200
Shaft Length
Product Number
FD1HA4X
10 15/64 (260)
FD1S166
FD1HA4X
17 7/8 (454)
FD11HA
11 21/38 (296)
FD11HA
16 15/64 (430)
166mm or
6 17/32in.
360mm or
14 11/64in.
200mm or
7 7/8in.
319mm or
12 19/32in.
Description
Contact Configuration
Location
Product Number
SPDT
NO
First
FD1ASNO1
SPDT
NC
First
FD1ASNC1
SPDT
NO
Second
FD1ASNO2
DPDT
2 NO
First
FD1ASNO11
DPDT
2 NC
First
FD1ASNC11
DPDT
2 NO
Second
FD1ASNO22
FD1S360
FD1S12
FD1L12
Auxiliary Switches
Switch Type
FD130, FD160, FD1100
or FD1200
FD130, FD160, FD1100
or FD1200
FD130, FD160, FD1100
or FD1200
FD130, FD160, FD1100
or FD1200
FD130, FD160, FD1100
or FD1200
FD130, FD160, FD1100
or FD1200
Operating Shafts
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-37
Section 9
Switch Type
Comments
Terminal Shields
FD130
Terminal Shields
FD160
Terminal Shields
FD1100
Terminal Shields
FD1200
Shorting Links
FD130
Shorting Links
FD160
Shorting Links
Shorting Links
Fuse Covers
FD1100
FD1200
FD130CC
FD130NF
FD130J
FD160J
FD160NF
FD1100
FD1200
All
Fuse Covers
Fuse Covers
Fuse Covers
Fuse Covers
Auxiliary Switch
Terminal Shields
Product Number
FD130TS
FD160TS
FD1100TS
FD1200TS
Terminal Shields
FD130LNK
FD160LNK
FD1100LNK
FD1200LNK
FD130CV1
FD130JCV1
FD160JCV1
Package of 2.
FD1100JCV1
FD1200JCV1
FD1ASCV1
Shorting Links
Lug Kits
Type
Description
Product Number
100A
200A
3 mech conn.
3 mech conn.
FD1LK1
FD1LK2
Fuse Covers
Lugs Kits
9-38
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Dimension A
Dimension B
Dimension C
Dimension D
Dimension E
Dimension F
FD130CC
FD130J
FD130NF
FD160J
FD160NF
FD1100J
FD1100NF
FD1200J
FD1200NF
4 19/64 (109)
4 19/64 (109)
4 19/64 (109)
4 41/64 (118)
4 41/64 (118)
6 21/32 (169)
6 21/32 (169)
9 27/32 (250)
9 27/32 (250)
3 23/64 (85)
3 11/32 (85)
3 23/64 (85)
4 23/32 (120)
4 23/32 (120)
6 7/32 (158)
6 7/32 (158)
8 21/32 (220)
8 21/32 (220)
4 21/64 (110)
4 21/64 (110)
4 21/64 (110)
5 19/32 (142)
5 19/32 (142)
7 11/64 (182)
7 11/64 (182)
9 17/32 (242)
9 17/32 (242)
3 15/64 (82)
3 15/64 (82)
3 15/64 (82)
3 15/16 (100)
3 15/16 (100)
4 9/64 (105)
4 9/64 (105)
5 29/32 (150)
5 29/32 (150)
4 13/32 (112)
5 15/64 (133)
4 13/32 (112)
4 49/64 (121)
4 49/64 (121)
4 59/64 (125)
4 59/64 (125)
7 (178)
7 (178)
M4
M4
M4
M4
M4
M6
M6
M8
M8
Approx. Net
Weight (Lbs.)
Minimum Enclosure
Size - Height (in.)
2.03
2.03
1.78
2.90
2.52
6.87
6.82
15.84
16.39
9.875
9.875
9.875
9.875
9.875
15.75
15.75
15.75
15.75
[2] F x .70 or
[2]# 6
B
C
Type FD1
Minimum Enclosure
Size - Width
6.875
6.875
6.875
7.875
7.875
11.50
11.50
11.50
11.50
Minimum Enclosure
Size - Depth
6.375
6.375
6.375
6.375
6.375
7.75
7.75
7.75
7.75
Approvals/Standards
UL Listed (UL 489)
CSA Certified (CSA 22.2 No. 4)
Meets service entrance requirements
CE Marked
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-39
Section 9
No. of
Poles
Horsepower
460 Vac
Horsepower
230 Vac
Product Number
3
3
3
3
3
10
15
20
25
30
5
7.5
10
15
15
D/061312-201
D/061314-201
D/061315-201
D/061324-201
D/061326-201
30A
60A
80A
100A
125A
Rated Current
at 40 C
Rated Current
at 50 C
Rated Current
at 60 C
Terminal
Capacity (CU)
Rated operational
voltage Ue
D/061312-201
40 A
40 A
40 A
690 V
D/061314-201
63 A
63 A
63 A
D/061315-201
80 A
80 A
80 A
D/061324-201
160 A
160 A
160 A
D/061326-201
200 A
200 A
200 A
6 mm2 Min.
50 mm2 Max.
6 mm2 Min.
50 mm2 Max.
6 mm2 Min.
50 mm2 Max.
Copper bus
maximum 6 x 20mm
Copper bus
maximum 6 x 20mm
DILOS 1
690 V
690 V
690 V
690 V
Rated Insulation
Voltage Ui
Rated Impulse
Voltage Uimp
Impulse Test
Voltage at
Sea Level
690 V
690 V
690 V
690 V
690 V
8 kV
8 kV
8 kV
8 kV
8 kV
12.3 kV
12.3 kV
12.3 kV
12.3 kV
12.3 kV
Rated Operation
Current Ie @
Utilization AC21A
at Ue=415V
Rated Operation
Current Ie @
Utilization AC22a
at Ue=415V
Rated Operation
Current Ie @
Utilization AC23A
at Ue=415V
40 A
63 A
80 A
160 A
200 A
40 A
63 A
80 A
160 A
200 A
40 A
50 A
80 A
125 A
160 A
DILOS 2
Rated Short-time
Withstand Current
Icw, 1 sec.
Rated Short-time
Withstand Current
Icw, 0.25 sec.
Peak Short-Circuit
Withstand Current
Rated Short-circuit
Making Capacity
Icm, Ue=400V
Rated Short-circuit
Making Capacity
Icm, Ue=415V
3 kA rms
3 kA rms
3 kA rms
3 kA rms
3 kA rms
6 kA rms
6 kA rms
6 kA rms
6 kA rms
6 kA rms
10 kA rms
10 kA rms
10 kA rms
10 kA rms
10 kA rms
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
9-40
Rated Conditional
Short-Circuit
Withstand
Current @ 400V
50 kA rms
50 kA rms
50 kA rms
50 kA rms
50 kA rms
Rated Conditional
Rated
Rated Operational
Short-Circuit
Operational
Current DC23A
Withstand
Current DC23A
(2P Series)
Electrical
Current @ 415V (2P Series) @ 110V
@ 220V
Durability
50 kA rms
50 kA rms
50 kA rms
50 kA rms
50 kA rms
BuyLog Catalog
40 A
63 A
80 A
160 A
160 A
40 A
63 A
100 A
100 A
1500 Cycles
1500 Cycles
1500 Cycles
1000 Cycles
1000 Cycles
Mechanical
Durability
20000 Cycles
20000 Cycles
20000 Cycles
10000 Cycles
10000 Cycles
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice
Section 9
Comments
Product Number
D/061901-001
D/061901-002
Auxiliary Switches
Padlocking Device
Comments
Product Number
D/061900-020
Padlocking Device
Inbus Key
Shaft Length
Comments
Product Number
200mm
S5 Insulated
D/061000-097
Inbus Key
Handle Color
Product Number
Black
Red/Yellow
Black
Red/Yellow
D/061910-002
D/061910-012
D/061910-004
D/061910-014
Lugs
Wire Size
#8-250 kcmil CU
Comments
Product Number
Package of 3
D/061922-003
Lugs
Rev. 11/13
Data subject to change
without notice
www.geindustrial.com
BuyLog Catalog
9-41
Section 9
Weight (Lbs.)
Weight (kg)
1.2
1.2
1.2
1.6
1.6
0.54 kg
0.54 kg
0.54 kg
0.73 kg
0.73 kg
Approvals/Standards
UL Listed (UL 489)
IEC 947-1, 947-3
EN 60947-3
DILOS 1
DILOS 2
9-42
BuyLog Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change
without notice