Sei sulla pagina 1di 2

CES 5.0 | | El.

Engineer
LQRG - 100 M Ohms
TEOA
The amount of apparent power that coukl flow into any fault at any point
in the electrical network.
DBRX
Vacuum
NGTS
40 kA
NVKP
Une fuses and overcurrent relays
ESFO
The input impedance is made much larger than the output impedance
WVMM
Differential amplifier
RNOO
Integrator
ELPL
Differentiator
FTAX
Protect the SCR against damage caused by fast high voltage spikes
XRGG
fo- 1 / (2"PiM sqrt (L/C))
BNLE
Figure 1
DTBG
Figure B
ABBG
Figure 1
UKRC
Allowing stored energy in solenoid to dissipate as freewheel current and
therefore prevent damage to transistor from inductive switching voltage.
KKHF
Return inductive current to supply at switch off.
SFGF
OR gate
KVVL
R1/R2 - R3/R4
GATR
Differentiating
GHLA
AND
KQUB
G - 1/R
RTXB
4.6V
ISPY
Measurement of differential pressure
LLXP
0.2 A
FKRP
One Henry
ARAJ
10-200
EUUQ
Multi - meter
HPMA
60 ohm
FEYS
A large bow thruster will draw very large currents at low voltage. Being
typically remote from the generator, significant voltage drops would occur at l
ow voltage.
CIPJ
To ensure that no energy remains in the system and that it cannot be rec
harged by external influences.
THJL
The gas, liquid or vapour which will minimise creation of an electric ar
c as contacts open.
WGVI
Rotten eggs.
YWKI
Electoc motors will run at reduced speed and will tend to overheat.
RSDC
Reduced current and reduced torque
WSOR
It will allow for inrush current or motor specific faults
CSMC
30 volts
WRW
In the event of an earth fault vital equipment will not tnp
JNMP
Faulty contactor coil
BGNJ
between 0.1 and 1.0 ohm
PDRS
Temperature, humidity and surface contamination
NVMA
Incorrect frequency
OKWA
6 ohms
TPDU
Zero-pomt is accurate, but 100% input is not Qivino 100% output
HQPC
Open arcurt winding between W and U
PEBH
Contactor chattering (vibrating)
NRXM
U-E, V-E. W-E, U-V,V-W, W-U
RPHF
The controller will not react to a process change in this range
EKVD
22 Ohms
TCKG
Disconnect the thermocouple lead from the controller and replace with a
mV source.
ACJL
One of the main switching elements in the tnac has failed.

SHXA
Install a 100 ohm resistor in series with the coil
WJUT
Apply reduced voltage to the element for a few minutes. Then retest and
if ok put into service.
VTAU
Solution of potassium hydroxide (KOH) and water
YYMW
Absolute pressure
CUFX
2.2 Ohms
QDFE
5 and 6
RGBR
Better linearity and increased accuracy
PBKR
The slave controller receives the set-point from the output signal of th
e master controller
YAPA
Adjust the slave controller with the master controller in manual mode
OSDY
The primary controller m a cascade control system
XNFD
Level control
XSES
It is possible to predict the control mathematically
DNNI
Control of the process inlet side
VXJJ
The secondary controller
DWOF
Capillary tube
SWQI
Figure 1
LKYH
In a pressure transmitter.
FXAI
Ionization type
OFXE
Thermocouple sensor
UDFB
Bandpass filter
CRQT
Pressure to current converter.