Sei sulla pagina 1di 2

4204/L/U Ultrasonic level

Transmitter

world class water monitoring series 42

Data Sheet

4204/L/U Ultrasonic level transmitter

Measure Data
Measuring ranges
Accuracy
Measuring Unit
Nr.2 Totalizers

Level: 0.30 5.00/0.40 8.00/ 0.70 12.00mt depending on the connected probe Temperature: -25 75 C
0.2% F.S.
Level: mt, cm, mm Temperature: C
Absolute: 9 digits- stored on a non-resettable Flash PROM
Partial: 9 resettable digits

Hardware Data
Display

Controls
DATA LOGGER
Serial Outputs
Analogue Outputs

128x64 Graphic display LCD STN backlighted Simultaneous display of: Instant
Flow (absolute + bargraph per percentuale fondo scala), totalized volume,
Temperature, State of the digital outputs, alarm events. In scrolling : Level, State of
the analogue outputs , Resettable totalizer
6 Buttons
Internal Flash 4Mbit Memory
n.1 RS485 MODBUS RTU with Galvanic Separation
n.2 Programmable outputs with Galvanic Separation
st

nd

Relay Outputs

1 output: Level/ Temperature 2 output: Temperature / Level


n.5 for thresholds - n.1 for alarm (max. Load 1A at 230Vac resistive)

Digital Inputs
Power Supply
Average absorption
Dimensions /Weight

n.5 Programmable
100240Vac/dc 50-60Hz (Optional 24Vac/dc) - Isolation Transf. 4KV
< 12W
Dimensions (L x H x P) 144x144x122,5mm - Weight: 1 Kg

Chemitec Srl Via I.Newton, 28 - 50018 Scandicci (FI) Italy tel. 0039 055 7576801 fax 0039 055 756697 sales@chemitec.it www.chemitec.it

world class water monitoring series 42

4204/L/U Ultrasonic level


Transmitter
Data Sheet

Analogue Outputs
Measure
Type

Primary

Secondary

Level

Level / Temperature

0.00 20.00 mA / 4.00 20.00 mA


Programming Limit: Inferior / Superior

Range
Max. Load

500 Ohm

Alarm output: NAMUR

2.4 mA (with 4/20mA Range)

nr.5 Relay Outputs


Function selectable
Programming

Thresholds

Impulses

ON-OFF with hysteresis


Alarm

Echo loss alarm


Time Out ( echo time lack): 00:00 24:00 h

Function
Programming
Operating conditions
Working Temperature - Storage
and Transport
Humidity
Mechanical protection
EMI / RFI

050C -2565C
10-95% non-condensing
Closed: IP66 EN60529
CEI-EN55011 05/99

S425/C Ultrasonic transducers 0,35m, 0,48m, (0,7...12m optional)

Materials:
Thread:
Measuring ranges:
Measuring method:
Mechanical protection:
Electrical connection:
Power supply / Absorption:
Working Temperature:
Working Pressure:
Current output:
Accuracy:
Resolution:
Digital communication:
Emission angle:

PVDF/PCV Body
S425/C 5meters: 1BSP M and 1,5BSP M
S425/C 8meters: 1BSP M and 2BSP M
S425/C 5meters: 30cm - 500cm
S425/C 8meters : 40cm - 800cm
Ultrasonic with automatic temperature compensation
IP67 (IP68 optional)
IP67 connector with 5m cable.
24Vdc / 2W
-10C +75C
from 0,5bar to 1,5bar
optional (500 ohm max load)
+-0,2% of the measured distance, not better than 2mm
1mm
Standard Modbus RTU
S425/C 5 meters: 14+-1
S425/C 8 meters: 10 +-1

Chemitec Srl Via I.Newton, 28 - 50018 Scandicci (FI) Italy tel. 0039 055 7576801 fax 0039 055 756697 sales@chemitec.it www.chemitec.it