Sei sulla pagina 1di 3

33L

Electronic pressure switches


Vacuum and relative pressure -1 to 600 bar

Diagnostic function acc. to DESINA


Display of system pressure
Easy programming of switchpoints
Economic solution for industrial applications
Switching status indicated by 3-colour LED display
Free of laquer impairing substances

Technical data
Medium:
Gaseous, liquid, aggressive and neutral, non-combustible
Electrical connection:
M 12 x 1
Mounting:
Optional
Fluid temperature:
-25C to + 80C
Ambient temperature:
-20C to + 80C
Consult our Technical Service for use below +2C.

Pressure range:
-1 to 1 / 16 / 40 / 100 / 160 / 250 / 400 / 600 bar
Temperature sensitivity (zero point):
0,4% of final value/10 K
Temperature sensitivity (range):
0,4% of final value/10 K
Switching point:
Adjustable between 0 to 100% of FS
Reset point:
Adjustable between 0 to 100% of FS
Accuracy:
1,5% FS
(Linearity, hysteresis, repeatability)
Degree of protection to DIN 40 050:
IP65 (<10bar) / IP67 (>10bar), with plug mounted
Shock protection:
30g, xyz, DIN EN 60068-2-27
Vibration protection:
10g, 5 to 500 Hz, xyz, DIN EN 60068-2-6
Weight:
0,06 kg

Ordering information
See page 2

Electrical information
See page 2

Materials
Housing: aluminium, stainless steel, polyester
Wetted parts:
-1 to 16 bar: aluminium, ceramics, FKM (viton)
40 to 600 bar: atainless steel, ceramics, FKM (viton)
All parts free of laquer impairing substances

4/04

Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.

N/UK 5.11.371.01

33L

Electrical information
Electrical connection:
Power supply:
Permissible residual ripple:
Current consumption:
Switching mode:
Output signal:

M12 x 1
UB =18 to 32 V d.c., polarity safe
10% (within UB)
< 100 mA (plus load current)
PNP, Potential-bound open collector switching to UB
Out 1: switching: UB minus 1.5V / Imax. 250 mA
Out 2: diagnostic/switching UB minus 1,5V/250 mA
Surge and short-circuit protection (Out1/Out2)
NO/NC programmable
< 10 ms
min. 50 million switching cycles
Interference emission acc. to EN 61326
Interference immunity acc. to EN 61326 Part 1

Switching logic Out 1 & 2:


Response time:
Service life:
Electromagnetic compatibility:

Pressure range (bar)#

Max. value (bar)##

Fluid connection*

Output signal**

-1 ... 1 bar
-1 ... 1 bar
0 ... 10 bar
0 ... 10 bar
0 ... 16 bar
0 ... 16 bar
0 ... 40 bar
0 ... 40 bar
0 ... 100 bar
0 ... 100 bar
0 ... 160 bar
0 ... 160 bar
0 ... 250 bar
0 ... 250 bar
0 ... 400 bar
0 ... 600 bar
0 ... 600 bar

6
6
25
25
40
40
100
100
175
175
280
280
400
400
700
1000
1000

G1/4
Flange
G1/4
Flange
G1/4
Flange
G1/4
Flange
G1/4
Flange
G1/4
Flange
G1/4
Flange
Flange
G1/4
Flange

2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP
2 x PNP

Display step size (bar)

Model

0,01
0,01
0,05
0,05
0,1
0,1
0,2
0,2
0,2
0,2
1,0
1,0
1,0
1,0
2,0
3,0
3,0

0860110
0860116
0860120
0860126
0860130
0860136
0860140
0860146
0860150
0860156
0860160
0860166
0860170
0860176
0860186
0860190
0860196

* Versions with fluid connection 1/4 NPTF on request, versions with bleeder screw on request
** Mode of OUT2 is programmable: Diagnostic acc. to DESINA / switching, switching logic of OUT1 and /OUT2 is programmable (NO/NC)
# Versions with pressure unit psi on request
## Max. value = over pressure. Short-term pressure peaks are not allowed to exceed this limit value during operation.
Operative utilization of the overload range is not permitted.

Options selector
08601
Pressure ranges (bar)
-1 ... 1
0 ... 10
0 ... 16
0 ... 40
0 ... 100
0 ... 160
0 ... 250
0 ... 400
0 ... 600

Substitute
1
2
3
4
5
6
7
8
9

Fluid connection
G1/4
Flange

Substitute
0
6

Ordering information
Electronic pressure switch, pressure range 0 to 16 bar, fluid connection G 1/4 female
quote: 0860130

Factory setting
Setting

NORGREN

Code

None

Pressure unit

Bar**

OUT 1
Switching logic
(NO/NC)

Switch point
(% of range)

Reset point
(% of range)

OUT 2*
Switching logic
(NO/NC)

Switch point
(% of range)

Reset point
(% of range)

Display
Colour
zero point
suppression
(% of range)

NO

50%

48%

DESINA (NC)

2%

Yellow

Brightness

50%

* OUT 2 function is programmable: diagnostic acc. to DESINA /switching


** p.s.i. on request

N/UK 5.11.371.02

Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.

4/04

33L

Accessories
Pressure port
reducing nipple

Snubber

Connector M 12x1
90
5 pins (on PE-requirement)

Connector M 12x1
90
4 pins

Connector M 12x1
Straight
4 pins

0574767

0574773

0799845 (2 m cable length)


0250081 (5 m cable length)

0523058 (2 m cable length)


0523053 (5 m cable length)

0523056 (without cable)

25

M12x1

25

M12x1

19,5

5,5
20

30

30
G1/4, 12 deep or 1/4 NPT, 10 deep

LED Out 2 (on/off)

Bleeder screw on request

Electrical connection M 12 x 1

Pressure port
reducing nipple

Display
Cable

+U
Out 2 (diagnostic/switch, PNP)
0V
Out 1 (switch, PNP)
NC

Brown
White
Blue
Black

Red blinking / LED


Yellow / green

Material: brass
Model: 0574773
Material: stainless steel
(1.4301)
Model: 0553258

G 1/4 A

G 1/4 A
22

22

31

1
2
3
4
5

Snubber

Material: brass
Model: 0574767
Material: stainless steel
(1.4301)
Model: 0550083

Electrical connection M12 x 1


Pin no.
Signal

5
1

Accessories

5
4

46

43

5
1

1,2

34

30

20

30

5,5

3
7,5

3
7,5

19,5

70

70

82,8

82,8

0523057 (2 m cable length) 0523055 (without cable)


0523052 (5 m cable length)

G 1/4

G 1/2 A
21,5

Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under Technical Data.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications
not within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid power
systems can fail in various modes.

N/UK 5.11.371.03

The system designer is warned to consider the failure modes of all


component parts used in fluid power systems and to provide adequate
safeguards to prevent personal injury or damage to equipment in the
event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.

Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.

4/04

Potrebbero piacerti anche