VRF
C A T A L O G U E
2 0 1 2
YOUR CONDITIONS!
Since 1916,
pioneers in the US market, by designing and manufacturing innovative air conditioning and
heat pump units. The companys primary competitive advantage is the use of its know-how expertise gained in the past,
to build air conditioning systems of the future.
The key to
units' success is that they are specifically designed to enable the modern individual invent his
own custom made living and working conditions. Regulating effectively the natural environment,
units can create silently the perfect indoor conditions; your conditions!
All
units carry a
2-year Warranty for the compressor and for all parts of the unit.
index
INV
Features
Pages
Higher Efficiency
Better Comfort
Higher Reliability
Better Versatility
Easy Installation & Maintenance
INV Mini
4-5
6-7
8-9
10-11
12-13
14-15
Outdoor Units
Pages
Line up
Specifications
16-17
18-21
Indoor Units
Pages
Line up
Duct Type
Slim Duct Type
Four-way Cassette Type
One-way Cassette Type
Floor Standing Type
Wall Mounted Type
Floor Ceiling Type
Concole Type
Treated Fresh Air Duct Type
22-23
24-27
28-29
30-33
34
35
36-37
38-40
41
42-43
Control System
Pages
44-45
46
47
48-49
50-51
52
53
54
55
56
57
58
59
60-61
62-63
64-66
67
3
HIGHER EFFICIENCY
) Significantly improved EER/COP
Significantly greater efficiency is realized by the use of DC Inverter
Hermetic Scroll Compressors with high-pressure chamber
design, improved DC inverter driving technology and large heat
exchanger.
27%
18%
increase of EER
increase of COP
4.37
4.07
4.0
4.0
3.7
3.5
3.5
3.2
3.0
3.0
2.5
2.5
Former
model
INV
Former
model
INV
Heat Exchanger
Fan Motor
EER is the efficiency rate= cooling capacity (kW) cooling power input (kW)
COP is the coefficient of performance = heating capacity (kW) heating power input.
Compressor
Orbiting
Scroll
Discharge
Intermediate
Pressure
Low
Pressure
Intermediate
Pressure
Chamber
Motor in
high Pressure
HP chamber
structure can
raise the high
and middle
frequency
performance
New DC motor
(concentrated winding)
raises the low frequency
performance
) DC Fan motor
Compared with the former model, airflow volume is increased 3% with the same single fan and 7% with the new
dual fan, but the power consumption is decreased by 5% with the DC inverter motor.
8HP/10HP Models
INV
Former model
3%
Former
model
INV
12HP/14HP Models
Former model
INV
7%
Former
model
INV
) Heat Exchanger
The bigger condenser increases
the heat-exchange area, improving
the efficiency.
Former model:
2098x38.1x1156
Former model:
Normal flat fin
INV:
INV:
2248x38.1x1190
Compressor efficiency
Distributed winding
Concentrated winding
7%
0
20
BETTER COMFORT
) Quiet Operation
Quiet operation during night time
The Intelligent adjustment of the outdoor
fan control can minimize the operation
noise during night time.
It can be reduced up to 8dB(A).
So the operating noise at night is lower,
at 50dB(A).
58dB(A)
Capacity Operating
sound
50dB(A)
Capacity Operating
sound
Heat load
Quiet compressor
Average
2dB(A) down
Optimized
Original design
INDOOR UNIT
37dB(A)
Office
Duct Type with High ESP
37dB(A)
Hotel
Slim Duct Type
37dB(A)
Reception
Four-way Cassette Type
28dB(A)
Bedroom
Wall Mounted Type
) Comfortable
Temperature
fluctuation of
the room
Less Cool
Uncomfortable
Comfortable
Cooler
Uncomfortable
INV
Defrosting
Heating
Defrosting
Heat Loss
Non VRF
Heating Capacity
Time
10mins
50mins
10mins
50mins
10mins
Defrosting
Heating Capacity
Heating
Time
Defrosting starts if the unit detects frost
Defrosting stops
after completion
Individual control
The set temperature of each room may vary by the individual thermostat control of each indoor unit.
OFF
260C
220C
200C
240C
270C
HIGHER RELIABILITY
) Modular operating
The operating priority sequence of the outdoor unit
modules will be changed without restart when the
system accumulatively operates for 12 hours. This
can maximize the service life of the system.
12hours
Rotation
Emergency operation
Each module is an independent sub-system. The whole
system wont fail down even if partial malfunction occurs.
If a malfunction occurs at any module, there can be performed
an emergency operation. This can simply be achieved
by setting up manually the outdoor PCB switches.
12hours
Rotation
Operating
Malfunction
12hours
Rotation
Emergency
Operation
12hours
Rotation
Failure
With power supply security, the outdoor unit will start autoprotection if the power voltage or the current is out of the
normal range. Protection will be relived automatically if the
power condition resumes normal.
342V
456V
Safe operation range
) Anti-corrosion
The primary material of Golden Fin is Al-Mn (Aluminum-Manganese) anti-rust alloy, which is coated with the Golden Protection
Layer (Components: Epoxy Resin & Modified Acrylic, Silicon
free). The anti-corrosive performance in salt-spray testing is
200%-300% higher than normal Blue Fin*.
Hydrophilic Layer
Golden Protection Layer
(Epoxy resin & Modified Acrylic)
Al-Mn-corrosive alloy
Air outlet
Negative pressure
Electric Box
Baffle
Electric Box Cover
Backflow
Guide louver
Positive pressure
Air inlet
Front pane
New patented oil separator allows the oil separating efficiency up to 99%.
Oil equalizing pipe connection designed at the outside of the module allows high reliability.
Before Oil Balanced
Compressors
Oil storage
tank
BETTER VERSATILITY
) Long piping design
Maximum total piping length --- 500m
Maximum actual piping length --- 150m
Maximum equivalent piping length --- 175m
Maximum height difference between indoor units --- 15m
Maximum height difference between outdoor
and indoor units --- 50m*
Maximum piping length from first indoor branch to the
farthest indoor unit --- 40m
15m
40m
150m
50m
* This value is based on the case that the outdoor unit is located above the
indoor unit. If the outdoor unit is located underneath the indoor unit, the value
is 40m.
If the required capacity of indoor units is 50% higher than the outdoor unit,
the cooling range may be lower up to 150C
If the required capacity of indoor units is 50% lower than the outdoor unit, the
cooling range may be up to 50C.
10
Heating
Cooling
) Compact Design
Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
Former model (8HP)
INV (8HP)
1670mm
1772mm
17%
reduction
880mm
770mm
990mm
Floor area: 0,87m
930mm
2
INV (16HP)
41%
1670mm
1772mm
reduction
880mm
(990+990)mm
Floor area: 1,74m2
770mm
1340mm
) Various combinations
Up to 110 sets of indoor units can be connected*
*For the standard model that 4 models connect in parallel, up to 64 indoor
units can be connected. If more indoor units are required to be connected
please contact us.
11
12
Transportation by forklift
INV (16HP):
370kg
Compact design
With compact design, the outdoor unit can be carried to the roof of a building through elevator. No crane is needed.
Traditional Central Air Conditioner
INV
13
INV MINI
70m
30m
) Flexible Design
25m
10m
Compact Design
Compact size has been achieved by significantly reducing the width
of the outdoor units compared to previous models.
INV
1100mm
14%
1250mm
1250mm
Former Model
reduction
340mm
340mm
mm
14
950mm
185V
264V
Safe operation range
) High efficiency
) Comfort
Operation noise
3dB(A)
) Easy Installation
When total piping length is less than 50m
[(A+B+C+D+a+b+c+d) 50m],
no additional refrigerant is required.
) Capacity
MODEL
Capacity
Power Supply
HP
kW
INV-Pd100W/NaB-K
INV-Pd120W/NaB-K
INV-Pd140W/NaB-K
INV-Pd160W/NaB-K
3.5
10
4.0
12
5.0
14
6.0
16
15
MODEL
INV-Pdm224W/
NaB-M (8HP)
INV-Pdm228W/
NaB-M (10HP)
INV-Pdm335W/
NaB-M (12HP)
INV-Pdm400W/
NaB-M (14HP)
INV-Pdm450W/
NaB-M (16HP)
INV-Pdm504W2/
NaB-M (18HP)
INV-Pdm560W2/
NaB-M (20HP)
INV-Pdm615W2/
NaB-M (22HP)
INV-Pdm670W2/
NaB-M (24HP)
INV-Pdm730W2/
NaB-M (26HP)
INV-Pdm785W2/
NaB-M (28HP)
INV-Pdm850W2/
NaB-M (30HP)
INV-Pdm900W2/
NaB-M (32HP)
16
INV-Pdm280W/
NaB-M (10HP)
INV-Pdm335W/
NaB-M (12HP)
INV-Pdm400W/
NaB-M (14HP)
INV-Pdm450W/
NaB-M (16HP)
INV-Pdm224W/
NaB-M (8HP)
MODEL
INV-Pdm280W/
NaB-M (10HP)
INV-Pdm335W/
NaB-M (12HP)
INV-Pdm400W/
NaB-M (14HP)
INV-Pdm450W/
NaB-M (16HP)
INV-Pdm950W3/
NaB-M (34HP)
INV-Pdm1008W3/
NaB-M (36HP)
INV-Pdm1605W3/
NaB-M (38HP)
INV-Pdm1130W3/
NaB-M (40HP)
INV-Pdm1180W3/
NaB-M (42HP)
INV-Pdm11253W3/NaBM (44HP)
INV-Pdm1300W3/
NaB-M (46HP)
INV-Pdm11350W3/NaBM (48HP)
INV-Pdm1405W4/
NaB-M (50HP)
INV-Pdm1456W4/
NaB-M (52HP)
INV-Pdm1512W4/
NaB-M (54HP)
INV-Pdm1570W4/
NaB-M (56HP)
INV-Pdm1650W4/
NaB-M (58HP)
INV-Pdm1700W4/
NaB-M (60HP)
INV-Pdm1750W4/
NaB-M (62HP)
INV-Pdm1800W4/
NaB-M (64HP)
17
SPECIFICATIONS
INV Mini
RATING CAPACITY
HP
MODEL
Combination units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power consumption
Heating (kW)
Compressor
Type
m3/h
Airflow rate
CFM
Sound pressure level (dB(A))
Dimensions WxDxH (mm)
Net weight
Refrigerant charge
INV-Pd 100W/NaB-K
INV-Pd 120W/NaB-K
INV-Pd 140W/NaB-K
INV-Pd 160W/NaB-K
6
5.0-13.5
7
8
6.0-16.2
7.0-18.9
1-Phase, 220-240V, 50Hz
12.0
14.0
14.0
15.4
3.50
4.36
3.40
4.05
DC inverter dual-rotor type compressor x 1
6200
6000
3642
3525
58
58
950x340x1250
950x340x1250
111
111
7.5
7.5
Cooling: 10 to 48, Heating: -20 to 27
Cooling: 18 to 118.4, Heating: -4 to 81
5/8
5/8
3/8
3/8
10.0
11.0
2.86
2.60
Capacity
kg
6200
3642
58
950x340x1250
111
7.5
C
F
Operation range
Connection pipe
diameter
3.5
Gas
Liquid
inch
5/8
3/8
9
8.0-21.6
16.0
17.6
4.98
4.85
6400
3759
58
950x340x1250
115
7.5
3/4
3/8
Basic Module
RATING CAPACITY
HP
MODEL
Combination units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power consumption
Heating (kW)
Compressor
Configration*
m3/h
Airflow rate
CFM
Sound pressure level (dB(A))
Dimensions
WxDxH
Net weight
Operating range
Refrigerant charge
Capacity
Gas
Liquid
18
kg
C
F
Operation range
Connection pipe
diameter
mm
inch
8
INV-Pdm 224W/
NaB-M
10
INV-Pdm 280W/
NaB-M
12
INV-Pdm 335W/
NaB-M
14
16
14.0 - 37.8
16.8 - 45.2
3-Phase, 380-415V, 50Hz
22.4
28.0
33.5
25.0
31.5
37.5
5.52
7.52
9.23
5.82
7.70
9.38
DCx1+Cx1
10000
10000
13000
5874
5874
7636
58
58
60
930x770x1670
255
255
350
275
275
380
12
13
15
Cooling: -5 to 48, Heating: -20 to 27
Cooling: 23 to 118.4, Heating: -4 to 81
7/8
7/8
9/8
3/8
3/8
1/2
14
11.2 - 30.2
14
INV-Pdm 400W/
NaB-M
16
INV-Pdm 450W/
NaB-M
16
20.0 - 54.0
16
22.5 - 60.8
40.0
45.0
12.45
11.2
DCx1+Cx2
13000
7636
61
1340x770x1670
350
380
16
45.0
50.0
14.32
13.90
9/8
1/2
13000
7636
61
370
400
17
9/8
1/2
Combination Modules
RATING CAPACITY
HP
MODEL
Combination units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power consumption
Heating (kW)
Compressor
Configration*
m3/h
Airflow rate
CFM
Sound pressure level (dB(A))
Dimensions
WxDxH
Net weight
Refrigerant charge
Capacity
kg
C
F
Operation range
Connection pipe
diameter
mm
Gas
Liquid
RATING CAPACITY
Inch
HP
MODEL
Combination units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power consumption
Heating (kW)
Compressor
Configration*
m3/h
Airflow rate
CFM
Sound pressure level (dB(A))
Dimensions
WxDxH
Net weight
Refrigerant charge
Capacity
kg
C
F
Operation range
Connection pipe
diameter
mm
Gas
Liquid
Inch
18
INV-Pdm 504W2/
NaB-M
20
INV-Pdm 560W2/
NaB-M
22
INV-Pdm 615W2/
NaB-M
24
INV-Pdm 670W2/
NaB-M
26
INV-Pdm 730W2/
NaB-M
INV-Pdm 224W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 335W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 400W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 450W/
NaB-M
30
25.2-68
32
32
32
32
28.0-75.6
30.8-83.0
33.5-90.5
36.5-98.6
3-Phase, 380-415V, 50Hz
50.4
56.0
61.5
68.0
73.0
56.5
63.0
69.0
76.5
81.5
13.04
15.04
16.75
19.97
21.84
13.52
15.40
17.08
18.90
21.60
(DCx1+Cx1)x2
(DCx1+Cx1)+(DCx1+Cx2)
10000x2
10000+13000
5874x2
5874+7636
62
62
62
62
63
(930x770x1670)+(930x770x1670)
(930x770x1670)+(1340x770x1670)
255+255
255+255
255+350
255+350
255+370
13+13
13+15
13+15
13+16
13+17
Cooling: -5 to 48, Heating: -20 to 27
Cooling: 23 to 118.4, Heating: -4 to 81
9/8
9/8
9/8
9/8
11/8
5/8
5/8
5/8
3/4
3/4
28
INV-Pdm 785W2/
NaB-M
30
INV-Pdm 850W2/
NaB-M
32
INV-Pdm 900W2/
NaB-M
34
INV-Pdm 950W3/
NaB-M
36
INV-Pdm 1008W3/
NaB-M
INV-Pdm 335W/
NaB-M
INV-Pdm 450W/
NaB-M
INV-Pdm 400W/
NaB-M
INV-Pdm 450W/
NaB-M
INV-Pdm 450W/
NaB-M
INV-Pdm 450W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 400W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 280W/
NaB-M
INV-Pdm 450W/
NaB-M
32
39.3-106.0
32
32
48
48
42.5-114.8
45.0-121.5
47.5-128.3
50.4-136.1
3-Phase, 380-415V, 50Hz
78.5
85.0
90.0
96.0
101.0
87.5
95.0
100.0
108.0
113.0
23.55
26.77
28.64
27.49
29.36
23.28
25.10
27.8
26.60
29.30
(DCx1+Cx2)x2
[(DCx1+Cx1)x2]+(DCx1+Cx2)
13000x2
10000x2+13000
7636x2
5874x2+7636
63
63
63
64
64
(1340X770X1670)+(1340X770X1670)
(930x770x1670)+(930x770x1670)+(1340x770x1670)
350+370
350+370
370+370
255+255+350
255+255+370
15+16
18+17
17+17
13+13+16
13+13+17
Cooling: -5 to 48, Heating: -20 to 27
Cooling: 23 to 118.4, Heating: -4 to 81
11/8
11/8
11/8
11/8
11/8
3/4
3/4
3/4
3/4
3/4
19
Combination Modules
RATING CAPACITY
HP
MODEL
Combination
units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power
consumption Heating (kW)
Compressor
Configration*
m3/h
Airflow rate
CFM
Sound pressure level (dB(A))
Dimensions
WxDxH
Net weight
Refrigerant charge
Capacity
kg
C
F
Operation range
Connection
pipe diameter
mm
Gas
Liquid
RATING CAPACITY
Inch
HP
MODEL
Combination units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power
consumption Heating (kW)
Compressor
Configration*
m/h
Airflow rate
CFM
Sound pressure level (dB(A))
Capacity
Dimensions
WxDxH
Net weight
Refrigerant charge
kg
Operation range
C
F
Connection
pipe diameter
Gas
Liquid
20
mm
Inch
38
40
42
44
46
48
INV-Pdm
1065W3/NaB-M
INV-Pdm
1130W3/NaB-M
INV-Pdm
1180W3/NaB-M
INV-Pdm
1235W3/NaB-M
INV-Pdm
1300W3/NaB-M
INV-Pdm
1350W3/NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm335W/
NaB-M
INV-Pdm400W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm335W/
NaB-M
INV-Pdm400W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
48
53.3-143.8
48
48
48
48
48
56.5-152.6
59.0-159.3
61.81-166.7
65.0-175.5
67.5-182.3
3-Phase, 380-415V, 50Hz
106.5
113.0
118.0
123.5
130.0
135.0
119.0
126.5
131.5
137.5
145.0
150.0
31.07
34.29
36.16
37.87
41.09
42.96
30.98
32.80
35.50
37.18
39.00
41.70
(DCx1+Cx1)+[(DCX1+Cx2)x2]
(DCx1+Cx2)x3
10000+13000x2
13000X3
5874+7636x2
7636x3
64
64
64
65
65
65
(930x770x1670)+(1340x770x1670)+(1340x770x1670)
(1340x770x1670)+(1340x770x1670)+(1340x770x1670)
255+350+370
350+370+370
350+370+370
370+370+370
13+15+17
13+16+17
13+17+17
15+17+17
16+17+17
17+17+17
Cooling: -5 to 48, Heating: -20 to 27
Cooling: 23 to 118.4, Heating: -4 to 81
1 5/8
1 5/8
1 5/8
1 5/8
1 5/8
1 5/8
3/4
3/4
3/4
3/4
3/4
3/4
50
INV-Pdm1405W4/
NaB-M
52
INV-Pdm1456W4/
NaB-M
54
INV-Pdm1512W4/
NaB-M
56
INV-Pdm1570W4/
NaB-M
58
INV-Pdm1650W4/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm280W/
NaB-M
INV-Pdm335W/
NaB-M
INV-Pdm400W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm400W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
64
78.5-212.0
64
82.5-222.8
155.0
176.5
48.61
46.70
(DCx1+Cx1)+[(DCx1+Cx2) x3]
10.000+13.000x3
5.874+7.636x3
65
163.0
181.5
50.48
49.90
64
70.3-189.7
64
64
72.8-196.6
75.6-204.1
3-Phase, 380-415V, 50Hz
141.0
146.0
151.5
158.0
163.0
169.0
41.84
43.68
45.39
40.05
43.20
44.88
[(DCx1+Cx1) x2]+[(DCx1+Cx2)x2]
10.000x2+13.000x2
5.874x2+7.636x2
65
65
65
(930x770x1.670)+(930x770x1.670)+
+(1.340X770X1670)+(1.340X770X1.670)
255+255+350+370
13+13+16+17
1 3/4
7/8
65
(930x770x1.670)+(1.340x770x1.670)+
+(1.340x770x1670)+(1.340x770x1.670)
255+370+370+370
13+17+17+17
2 1/8
1
Combination Modules
RATING CAPACITY
MODEL
HP
Combination
units
Connectable
indoor unit
Power supply
Maximum
Cooling Capacity (kW)
Cooling (kW)
Heating (kW)
Cooling (kW)
Power
consumption Heating (kW)
Compressor
Configration*
m3/h
Airflow rate
CFM
Sound pressure level (dB(A))
Dimensions
WxDxH
Net weight
Refrigerant charge
Capacity
kg
C
F
Operation range
Connection
pipe diameter
mm
Gas
Liquid
Inch
60
INV-Pdm1700W4/NaB-M
62
INV-Pdm1750W4/NaB-M
64
INV-Pdm1800W4/NaB-M
INV-Pdm335W/
NaB-M
INV-Pdm400W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
INV-Pdm450W/
NaB-M
64
85.0-230.0
64
64
87.5-236.3
80.0-243.0
3-Phase, 380-415V, 50Hz
168.0
175.0
180.0
187.5
195.0
200.0
52.19
55.41
57.21
51.80
52.90
55.60
(DCx1+Cx2) x4
13000x4
7636x4
66
66
66
(1340x770x1670)+(1340x770x1670)+(1340x770x1670)+(1340x770x1670)
350+370+370+370
15+17+17+17
16+17+17+17
17+17+17+17
Cooling: -5 to 48, Heating: -20 to 27
Cooling: 23 to 118.4, Heating: -4 to 81
2 1/8
2 1/8
2 1/8
1
1
1
C: Constant speed scroll compressor
21
Duct Type
(EXV Integrated)
Concole Type
22
2.2
2.8
3.6
4.5
5.0
5.6
6.3
7.1
8.0
9.0
10.0
11.2
12.5
14.0
22.4
28.0
23
DUCT TYPE
) Highly flexible installation
Highly flexible installation is possible to satisfy various needs
eeds
Installation examples
Indoor unit
Supply air duct
Canvas air duct
Indoor unit
Long life filter
Maintenance access
24
) Easy maintenance
Long life and washable filter with buckles can be easily disassembled from each direction.
Compact size has been achieved by significantly reducing the width of the outdoor units compared
to previous models.
Former model
ESP (Pa)
Former model
High ESP of new model
Model (kW)
Model (kW)
) Key-card control
25
INV-R22PS/NaB-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
Airflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Standard Esp (H/L) (Pa)
Dimensions (WxDxH) (mm)
Net weight (Kg)
Inch
Gas (Flare)
mm
Connection
pipe
Inch
Liquid (Flare)
mm
External dia. mm
Drain Pipe
Thickness
mm
MODEL
2.2
2.5
75
450
265
37/35/33
50/20
28.5
3/8
9.52
1/4
6.35
20
1.5
INV-R56PS/
NaB-K
INV-R28PS/NaB-K
INV-R71PS/
NaB-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
Airflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Standard Esp (H/L) (Pa)
Dimensions (WxDxH) (mm)
Net weight (Kg)
Inch
Gas (Flare)
mm
Connection
pipe
Inch
Liquid (Flare)
mm
External dia. mm
Drain Pipe
Thickness
mm
26
INV-R36PS/NaB-K
5.6
7.1
6.3
8.0
240
240
1.000
1.100
589
647
44/42/40
45/43/41
60/30
60/30
1155x756x300
51
51
5/8
5/8
15.9
15.9
3/8
3/8
9.52
9.52
30
30
1.5
1.5
INV-R90PS/
NaB-K
1-Phase, 220-240V, 50Hz
9.0
10.0
360
1.700
1.000
48/46/44
80/40
64
5/8
15.9
3/8
9.52
30
1.5
INV-R45PS/NaB-K
4.5
5.0
140
700
412
40/38/36
50/20
980x721x266
36
1/2
12.7
1/4
6.35
30
1.5
INV-R112PS/
NaB-K
INV-R140PS/
NaB-K
11.2
12.5
360
1.700
1.000
48/46/44
80/40
1425x736x300
64
5/8
15.9
3/8
9.52
30
1.5
14.0
15.0
500
2.000
1.177
50/48/46
100/50
65.5
5/8
15.9
3/8
9.52
30
1.5
IN-R22P/
NaB-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
Airflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Standard Esp (H/L) (Pa)
Dimensions (WxDxH) (mm)
Net weight (Kg)
Inch
Gas (Flare)
mm
Connection
pipe
Inch
Liquid (Flare)
mm
External dia. mm
Drain Pipe
Thickness
mm
MODEL
2.2
2.5
75
450
265
37/35/33
50/20
27
3/8
9.52
1/4
6.35
20
1.5
INV-R90P/
NaB-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
Airflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Standard Esp (H/L) (Pa)
Dimensions (WxDxH) (mm)
Net weight (Kg)
Inch
Gas (Flare)
mm
Connection
pipe
Inch
Liquid (Flare)
mm
External dia. mm
Drain Pipe
Thickness
mm
9.0
10.0
360
1.700
1.000
48/46/44
80/40
62
5/8
15.9
3/8
9.52
30
1.5
INV-R28P/
NaB-K
INV-R36PS/
NaB-K
INV-R45P/
NaB-K
INV-R112P/
NaB-K
1-Phase, 220-240V, 50Hz
11.2
12.5
360
1.700
1.000
48/46/44
80/40
1425x736x300
62
5/8
15.9
3/8
9.52
30
1.5
INV-R56P/
NaB-K
4.5
5.0
140
700
412
40/38/36
50/20
980x721x266
34
1/2
12.7
1/4
6.35
30
1.5
INV-R140P/
NaB-K
14.0
15.0
500
2.000
1177
50/48/46
100/50
63.5
5/8
15.9
3/8
9.52
30
1.5
INV-R71P/
NaB-K
5.6
7.1
6.3
8.0
240
240
1.000
1.100
589
647
44/42/40
45/43/41
60/30
60/30
1155x756x300
49
49
5/8
5/8
15.9
15.9
3/8
3/8
9.52
9.52
30
30
1.5
1.5
INV-R224P/
NaB-M
INV-R280P/
NaB-M
27
200mm
700mm
4.5kW, 5.6kW
Only 200mm in height, which can be installed in rooms with little depth as 240mm depth between the drop ceiling and ceiling slab.
Suspension bolt
Suction duct*
200mm
AIR
900mm
Discharge grille
Air filter
Suction grille
AIR
Example 2
Return air inlet
Indoor unit
28
Maintenance access
Long-life filter
) Lower noise
Plastic propeller housing, fan blade and intelligent-designed air-channel ensure air flow volume with lower operation noise.
For example the normal unit of 2.8kW has noise level up to 40dB(A), but the new unit of 2.8kW reduces the noise up to only
37dB(A).
MODEL
INV-R22P/
NaE-K
INV-R28P/
NaE-K
2.2
2.5
64
450
265
37/35/33
20
2.8
3.2
64
450
265
37/35/33
20
700x615x200
21
3/8
9.52
1/4
6.35
20
1.5
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
Airflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Standard Esp (Pa)
Dimensions (WxDxH) (mm)
Net weight (Kg)
Inch
Gas (Flare)
mm
Connection
pipe
Inch
Liquid (Flare)
mm
External dia. mm
Drain Pipe
Thickness
mm
21
3/8
9.52
1/4
6.35
20
1.5
INV-R36P/
NaE-K
INV-R45P/
NaE-K
INV-R56P/
NaE-K
INV-R71P/
NaE-K
7.1
8.0
100
1000
589
42/40/38
20
1100x615x200
30
5/8
15.9
3/8
9.52
30
1.5
29
) Four
Four-way
way Cassette Type
Compact, light weight and square panel in the same size for
easy installation.
Compact
act Four-way
Four way Cassette
Cassette
Type
Compact size of 650mm x 650mm for 2.8kW 5.6kW
650mm
960mm
960mm
30
650mm
Common characteristics
Low noise with 3 dimensional blade.
Diffuser
3-dimensional blade
The full-automatic operation, the 4-way air supply, the 3-speed fan setting and the strong circulating air flow volume, make the
cooled or heated air to reach directly every corner of the room. This can be succeded even if the ceiling is higher than standard
height.
The units below 7.1kW are applicable to
height below 3m.
31
INV-R28T/Na-K
Cooling (kW)
Heating (kW)
Power consumption (W)
m3/h
Aiflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Capacity
Connection
pipe
Drain Pipe
Main body
Panel
Gas (Flare)
Liquid (Flare)
Inch
mm
Inch
mm
MODEL
Power supply
Cooling (kW)
Heating (kW)
Power consumption (W)
m3/h
Aiflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Drain Pipe
Main body
Panel
32
25
6.5
INV-R56T/Na-K
Capacity
Connection
pipe
2.8
3.2
65
680
400
37/35/33
3/8
9.52
1/4
6.35
30
1.5
Gas (Flare)
Liquid (Flare)
Inch
mm
Inch
mm
5.6
6.3
83
1.180
694
39/37/35
5/8
15.9
3/8
9.52
30
1.5
30
6.5
INV-R36T/Na-K
INV-R45T/Na-K
INV-R63T/Na-K
INV-R80T/Na-K
INV-R50T/Na-K
5.0
5.8
65
680
400
37/35/33
1/2
12.7
1/4
6.35
30
1.5
25
6.5
INV-R90T/Na-K
9.0
10.0
133
1.860
1.095
40/38/36
5/8
15.9
3/8
9.52
30
3.5
840x840x320
38
6.5
INV-R100T/Na-K
Cooling (kW)
Heating (kW)
Power consumption (W)
m3/h
Aiflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Capacity
Connection
pipe
Drain Pipe
Main body
Panel
Gas (Flare)
Liquid (Flare)
Inch
mm
Inch
mm
10.0
11.0
133
1.860
1.095
40/38/36
5/8
15.9
3/8
9.53
30
1.5
38
6.5
INV-R112T/Na-K
INV-R125T/Na-K
INV-R140T/Na-K
14.0
14.5
133
1.860
1.095
40/38/36
5/8
15.9
3/8
9.52
30
1.5
38
6.5
INV-R22T/NaA-K
Cooling (kW)
Heating (kW)
Power consumption (W)
m3/h
Aiflow rate
CFM
Sound pressure level (H/M/L) (dB(A))
Capacity
Connection
pipe
Drain Pipe
Main body
Panel
Gas (Flare)
Liquid (Flare)
Inch
mm
Inch
mm
2.2
2.5
12
600
353
47/44/41
3/8
9.52
1/4
6.35
30
1.5
20
2.5
INV-R28T/NaA-K
INV-R36T/NaA-K
INV-R45T/NaA-K
4.5
5.0
12
600
353
47/44/41
1/2
12.7
1/4
6.35
30
1.5
20
2.5
33
ONE-WAY
CASSETTE TYPE
) High flexible
D i pump lift
) Drain
) Comfortable
Low noise cross flow fan reduces vortex flow in the duct thus
reducing the noise.
The equal and gentle air supply design and the advanced air flow
controlling design make the room temperature equal and balanced. So, the people inside the room feel more comfortable.
INV-R22Td/NaA-K
Cooling (kW)
Heating (kW)
Power consumption (W)
m3/h
Aiflow rate
CFM
Sound pressure level (dB(A))
Capacity
Connection
pipe
Drain Pipe
Main body
Panel
34
Gas (Flare)
Liquid (Flare)
Inch
mm
Inch
mm
2.2
2.5
42
450
265
45/43/41
3/8
9.52
1/4
6.35
30
1.5
16
3
INV-R28Td/NaA-K
1-Phase, 220-240V, 50HZ
2.8
3.2
42
500
294
45/43/41
3/8
9.52
1/4
6.35
30
1.5
920x360x185
16
118043030
3
INV-R36Td/NaA-K
3.6
4.0
42
500
294
45/43/41
1/2
12.7
1/4
6.35
30
1.5
16
3
FLOOR STANDING
TYPE
Wireless
FCU Wired remote controller WK-010PA-K
Auto diagnosis
Fashionable and novel appearance
Quiet operation
Intelligent drainage device
Long life filter
Wider air supply and swing angle
Dynamic color display
Horizontal and vertical swing
Cooling
Heating
Power supply
Motor power input
Air flow volume
Sound pressure level
Connecting pipe
Drain pipe
Dimensions
Net Weight
Gas
Liquid
External dia.
Thickness
WxDxH
Body
kW
kW
V/Ph/Hz
W
m3/h
CFM
dB(A)
inch
inch
mm
mm
mm
kg
INV-R71L/Na-K
INV-R100L/Na-K
INV-R140L/Na-K
7.00
8.00
220-240/1/50
160
1100/1000/920
655/595/548
48/45/42
5/8
3/8
31
4.5
502x316x1756
39.0
10.00
11.00
220-240/1/50
185
1600/1500/1300
952/893/774
51/49/47
5/8
3/8
31
4.5
556x381x1896
53
14.00
15.00
220-240/1/50
200
1700/1600/1400
1012/952/833
52/50/48
5/8
3/8
31
4.5
556x381x1896
57
35
Heating
After the unit is turned off, the indoor fan will still operate in low
speed in order to dry the inner components and parts. This way
mould and odor are prevented from growing.
) Ternary filters
Ternary air filters with anti-mildew, static electric dust capture and anti-bacterial function.
Ternary filter
) Washable grille
The front grille can be easily removed for washing.
36
MODEL
INV-R22G/
NaG-K
INV-R28G/
NaG-K
Cooling (kW)
Heating (kW)
Power consumption (W)
m3/h
CFM
Sound pressure level (H/M/L) (dB(A))
Dimensions (WxDxH)(mm)
Net weight (kg)
Inch
Gas (Flare)
mm
Connection pipe
Inch
Liquid (Flare)
mm
External dia. (mm)
Drain Pipe
Thickness (mm)
EXV Position
Aiflow rate
MODEL
2.2
2.5
50
500
294
38/36/34
m3/h
CFM
Sound pressure level (H/M/L) (dB(A))
Dimensions (WxDxH)(mm)
Net weight (kg)
Inch
Gas (Flare)
mm
Connection pipe
Inch
Liquid (Flare)
mm
External dia. (mm)
Drain Pipe
Thickness (mm)
EXV Position
Aiflow rate
2.8
3.2
50
500
294
38/36/34
3.6
4.0
60
630
371
44/41/38
10.5
3/8
9.52
1/4
6.35
28
4
13
1/2
12.7
1/4
6.35
28
4
843x180x275
10.5
3/8
9.52
1/4
6.35
28
4
4.5
5.0
60
630
371
44/41/38
940x200x298
13
1/2
12.7
1/4
6.35
28
4
Intergrated
INV-R50G/
NaG-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
INV-R45G/
NaG-K
Power supply
Capacity
INV-R36G/
NaG-K
5.0
5.8
60
630
371
44/41/38
940x200x298
13
1/2
12.7
1/4
6.35
28
4
INV-R56G/
NaG-K
INV-R71G/
NaG-K
INV-R71G/
NaB-K
INV-R80G/
NaB-K
7.1
8.0
8.0
9.0
63
65
1.200
1.200
706
706
49/45/42
49/45/42
1178x227x326
17.5
17.5
5/8
5/8
15.9
15.9
3/8
3/8
9.52
9.52
30
30
1.5
1.5
External
37
38
) Easy maintenance
Convenient disassembly and maintenance thanks to unique design.
Plastic filter with buckles
Grill buckle
Dismountable motor
39
INV-R28Zd/NaB-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
CFM
Aiflow rate
Sound pressure level (dB(A))
Dimensions (WxDxH) (mm)
Net weight (kg)
Connection
pipe
Drain Pipe
Inch
Gas (Flare)
mm
Inch
Liquid (Flare)
mm
External dia. (mm)
Thickness (mm)
MODEL
2.8
3.2
55
650
383
40
40
3/8
9.52
1/4
6.35
17
1.75
INV-R90Zd/NaB-K
Power supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
CFM
Aiflow rate
Sound pressure level (dB(A))
Dimensions (WxDxH) (mm)
Net weight (kg)
Connection
pipe
Drain Pipe
40
Inch
Gas (Flare)
mm
Inch
Liquid (Flare)
mm
External dia. (mm)
Thickness (mm)
9.0
10.0
180
1.600
942
51
1420x245x700
54
5/8
15.9
3/8
9.52
17
1.75
INV-R36Zd/NaB-K
INV-R50Zd/NaB-K
INV-R112Zd/NaB-K
INV-R125Zd/NaB-K
INV-R71Zd/NaB-K
7.1
8.0
140
1.400
824
49
1420x245x700
52
5/8
15.9
3/8
9.52
17
1.75
INV-R140Zd/NaB-K
14.0
16.0
250
2.000
1.777
55
66
5/8
15.9
3/8
9.52
17
1.75
CONCOLE TYPE
Vertical swing
Anti-cold function
Quiet operation
Comprehensive protection
Auto restart
Compact design
Easier maintainability
MODEL
INV-R28-C/Na-K
Power Supply
Cooling (kW)
Capacity
Heating (kW)
Power consumption (W)
m3/h
Air flow rate
CFM
Sound pressure level (H/M/L) (db(A))
Dimenions (WxDxH) (mm)
Net weight (kg)
inch
Gas
mm
Connection pipe
inch
Liquid
mm
2.8
3.2
60
500-430/370/280
294-253/218/165
38/33/26
3/8
9.52
1/4
6.35
INV-R36-C/Na-K
1-Phase, 220-240V,50Hz
3.6
4.0
60
600-520/440/360
353-306/259/212
40/37/32
700x215x600
16
3/8
9.52
1/4
6.35
INV-R28-C/Na-K
5.0
5.5
60
650-620/500/410
383-365/294/241
46/41/35
1/2
12.7
1/4
6.35
41
Note: The capacity of fresh air ducted unit should be less than 30% of the capacity of outdoor unit.
) Comfortable
Makes you feel comfortable, like in the nature. It is introducing
the outdoor fresh air, after treatment, in to the room.
42
) Easy control
Wired remote control
Centralized control
Long-distance monitoring
Sub-room switch
Memory function
Weekly timer
) Flexible application
The indoor unit with high static pressure can realize long-distance fresh air supply to all corners of the room. So, it is greatly
applicable to places that there is high density of people.
The standard pressure is 200Pa and the optional range is 50-300Pa.
MODEL
Power supply
Capacity
(At rated ESP)
Power input1
Aiflow Volume
Cooling (kW)
Heating (kW)
Cooling (kW)
Heating (kW)
CFM
m3/h
INV-R140P/
Na(X1.2)-K
INV-R224P/
Na(X2.0)-M
INV-R280P/
Na(X2.5)-M
INV-R280P/
Na(X3.0)-M
43
System
Communication module
ME30-00/E2
Group Controller
ZJA011
Communication module
ME30-00/E2
Wired Remote Controller
ZX60451
Key-card
IR Receiver Unit
JS01
(Field supplied)
Note:
Control network sketch is for reference only,
please refer to the equipment manuals for actual cable connection method.
44
Air Conditioning
Central Control
RS-232 to RS-422/485
Converter
Building
Management
FE30-00/A(M)
RS-232 to RS-422/485
Converter
Modbus network
IR receiver line
Key-card control board line
Internet
Communication module
ME30-00/E2
Centralized Controller
CE51-24/E(M)
45
CONTROLLERS COMPARISON
ITEM
Connections
Control
functions
Wired
Smart Centralized
Wired
Wireless Wireless
INVENTOR
BMS
Group
Remote
Controller
Zone
Remote
remote
remote
AC Eude- Interface
Controller
Controller
Controller CE51-24/
Controller
Controller controller
mon 2009 (Modbus)
ZJA011
Z63351F/
CE50-24/E E(M)
XK02
YB1FA
Y512
Z60351*
64
16
16
1024
n*255*16 n*255*16
16
16
1024
n*255*16 n*255*16
ON/OFF
Fan Speed
Vertical Swing
Turbo Mode
Light
Clock
0.5h
1min
0.5h
0.5h
0.5h
0.5h
1min
1sec
Weekly Timer
Group Shielding
Centralized Control
Group Control
Note:
n: Nos. of serial port
Control functions availability is based on the indoor units. Please refer to the users manual of indoor unit for details.
46
Lock
ON/OFF Timer
Centralized
Control
Week
Shielding
Room Temp.
Sleeping Mode
Errors
Timer
n*255
Mode Setting
Drying
Display
n*255
COMMENTS
OF CONTROL FUNCTIONS
) ON/OFF Timer Function
) Sleeping Function
) Error Display
When the malfunction occurs during
the operation, the room temperature display area will show the error
code.
The picture here shows the code of
compressor high-pressure protection.
Timer setting
Timer setting
60min
60min
1 0C
2 0C
1 0C
2C
) Memory Function
After power failure, if the unit is energized again, it will operate according to previous set, which includes setting temp,
fan speed, swing angle, energy-saving mode, blow function
etc.
) Blow Function
(Only for cooling and heating mode)
) Turbo Function
(In COOL or HEAT mode)
The unit operates at super-high fan speed so as to cool or
heat quickly so that the ambient temperature approaches
the set temperature as soon as possible
When the difference between the room temperature and the
set temperature is not more than 2C, this function will be
turned off automatically.
When the unit is turned off, the indoor fan will keep running at
low speed for 10min so as to dry the indoor evaporator,
in order to prevent mildew and keep users healthy.
This function can be memorized.
) Mute Function
(Only for cooling and heating mode)
) Shield Function
(Remote monitoring)
The indoor unit is operated by remote control. At the same
time the functions of the wired controller, such as ON/OFF,
temp., mode setting, energy saving function etc, are shield.
47
WIRED REMOTE
CONTROLLER
Z60351F/Z63351F (Heat pump)
51
1F (H
Hea
at pu
pump
mp
p)
Z60351F/Z63351F
(Heat
pump)
51
1F (C
Coo
ooli
ling
li
ng
go
onl
nlly)
nl
y)
y)
Z60151F/Z63151F
(Cooling
only)
ON/OFF
Temperature setting
Fan speed setting
Energy-saving function
Room temperature display
Sleep function
Infrared remote control function is available
and the remote controller is optional
ON/OFF Timer
Operation mode setting
Vertical swing
Self-diagnosis function (Error code display)
Memory function
Child lock function
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
ON/OFF button
Z63351F / Z60351F
DC12V (Supplied by the indoor unit)
85x85x20
94
* Z60351F is for duct type indoor unit, and swing function is unavailable;
Z63351F is for other types of indoor unit, button SLEEP changes to SWING, and sleep function is unavailable.
48
WIRED REMOTE
CONTROLLER
ZX60451
ON/OFF
Displayed as white characters on
black background
Fan speed setting
Self-diagnosis function (Error code
display)
Turbo cooling/heating function
Quiet function
Enquire and setting address of wired
controller
ON/OFF Timer
Temperature setting
Vertical swing
Environmental temperature display
Evaporation function
Shield function
Infrared remote control function is
available and the remote controller is
optional
Swing Display
Lock Display
Timer Display
Temperature /Timer /
Quiet Mode Setting button
On/Off Button
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
ZX60451
DC12V (Supplied by the indoor unit)
92x92x24
116
49
WIRELESS REMOTE
CONTROLLER
Y512
ON/OFF
Temperature setting
Fan speed setting
Child lock function
ON/OFF Timer
Operation mode setting
Vertical swing
Sleep function
ON/OFF Button
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
50
Y512
AAA 1.5Vx2
159x56x18
92
WIRELESS REMOTE
CONTROLLER
YB1FA
ON/OFF
Temperature setting
Fan speed setting
Energy-saving function
Room temperature display
Turbo cooling/heating function
Mute function
Child lock function
ON/OFF Timer
Operation mode setting
Vertical swing
Self-diagnosis function (Error code display)
Sleep function
Blow function
Memory function (Turbo, Energy save, Quiet,
Evaporation, etc. )
Clock display
Fan Speed
(HIGH, MID, LOW, AUTO)
Operating Mode Display
(AUTO, COOL, DRY, FAN, HEAT)
Temperature/
Timer Setting Button
Fan Speed Setting Button
Clock Setting Button
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
YB1FA
AAA 1.5Vx2
122x44x21
70
51
GROUP CONTROLLER
ZJA011
Note: Wired controller must be reserved with the indoor unit that has been matched.
Group wired controller could replace 1-16 selected wired controllers, in order to uniformly set or control the
indoor units.
Features:
It can uniform the time for the selected indoor units.
It can replace the wired controller, in order to control the selected indoor units in a region.
It has the function of power-off memory.
Note: The wired controller that is matched with the indoor unit must be removed and the indoor unit must be
re-energized after debugging.
Inquiry/Control Display
Lock Display
Swing Display
Set Temperature/Timer
Time Display
Timer Button
(Under SINGLE / CENTRAL Status)
ON/OFF Timer Inquiring of On-line Indoor Uni
(Under INQUIRY Status)
ON/OFF Button
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
52
ZJA011
DC12V (Supplied by the indoor unit)
85x85x20
94
SMART ZONE
CONTROLLER
CE50-24/E
When the indoor units are connected to 3 sets of INV outdoor units, the air duct type
indoor unit can be also connected.
Directly controls 16 indoor units in the network without extra communication module.
played
If an indoor unit is being operated by its own control group, it can be inquired and displayed
on the operation status.
Remote shield function.
Timer function.
Weekly Timer Function.
Timer Display
On/Off Button
Timer/Clock Setting Button
Max 16
Serial 1 (multirequency)
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
Serial 2 (multirequency)
Serial 3 (multirequency)
CE50-24/E
220V~240V, 50/60Hz
120x120x62
391
53
CENTRALIZED
CONTROLLER
CE51-24/E(M)
Clock setting.
Error alarm and error code display
Single/Group/Center Control
(including weekly timer setting, shield setting, etc)
64 communication modules can be connected and
1024 sets of indoor units can be controlled.
Error Display
CENTER/GROUP
Operating or Setting Display
ON/OFF Button
Cancel Button
Max 64
Communication
Module
Max 16
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
Communication
Module
Max 16
CE51-24/E(M)
220V~240V, 50/60Hz
185x131x68
557
* All indoor units connected by one communication module are automatically distributed in one region.
54
Communication
Module
Max 16
IR RECEIVER
& KEY-CARD CONTROL BOARD
JS01 / MK03
) IR receiver
JS01
It is applicable to INV duct type indoor unit
and equipped with LED lamp for status
indication and infrared remote control function.
LED Lamp
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
JS01
DC5V (Supplied by the indoor unit)
120x70x58.5
172
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
MK03
220V~240V, 50/60Hz or DC5V~24V (Supplied by the indoor unit)
73x73x36
65
55
COMMUNICATION
MODULE
ME30-00/E2
) Functions
The communication module (ME30-00/E2) is used for transforming and transmitting
signals of the computer and the air conditioning system. It acts as a communication
controller.
Modbus protocol and RS485 interface are adopted so that the unit can be connected to users BMS system and other networks.
Lots of monitoring nodes make possible to have as many as 255 units in the same network.
Control of setting parameter is available.
Monitoring of operation state is available.
Monitoring of malfunction state is available.
POWER
RS485 Interface
Unit
9~12V DC 800mA
Model Name
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
56
ME30-00/E2
220V~240V, 50/60Hz
185x131x68
557
COMMISSIONING PROGRAM
Text Parser
) Brief introduction
This software receives data from the INV system through local COM port or network (both internet and LAN are suitable) and
then analyses these data according to communication protocol.
Running parameters of unit, after analysis, will be displayed and saved in real time. There are two kinds of displaying methods,
the text displaying and the curve displaying. The analytic data can be saved in database. Technician and service person can use
this software to do commissioning.
Operating System
CPU
HDD
Memory
Curves Analysis
57
RS-422/485 R
REPEATER (ISOLATED)
) Functions
Rs-422/485 repeater (isolated) is used to amplify the communication signal when the
quantity of communication modules in the network is more than 30, or communication
distance is longer than 800m.
RS-422/485
RS-422/585
Power
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
58
RS-232 TO RS-422/485
CONVERTER (ISOLATED)
) Functions
RS232-RS485 opt electronic isolated converter is used for converting the signal between
computer / BMS System (RS232) and INVENTOR Air Conditioning Systems (RS485).
RS-422/485
RS-232
Power
Power Supply
Dimensions (HxWxD) (mm)
Weight (g)
59
INVENTOR AC EUDEMON
2009 PC SUIT
) Brief introduction of INVENTOR AC Eudemon 2009
009
INVENTOR AC Eudemon 2009 is the latest solution for controlling, monitoring and management of INVENTOR central air conditioning systems with your PC.
Maximum Connectable Systems/ Outdoor Units: 255
Maximum Connectable Indoor Units (INV System): 4,000
Maximum Control Distance: 5,600m (Standard distance 800m & extendable to 5.6km)
Compatible Systems: INV System, Centrifugal Chiller, Water-cooled screw chiller, Air-Cooled screw chiller,
Air-cooled scroll chiller, etc.
Personal Computer
BMS System
Serial Port
Max 255
More
AC Units
Convertor
RS485 Network
Protocol (Modbus)
Max 255
Communication
Module 1
Max 16
Communication
Module n
Max 16
Note:
In a RS485 Network, different type of systems cannot be connected.
User can only choose either INVENTOR AC Eudemon 2009 or BMS (Modbus) to manage the Air-conditioner system.
60
Communication
Module 255
Max 16
Content
Software Environment
61
62
Operating System
CPU
HDD
Memory
Software Environment
63
ENERGY RECOVERY
VENTILATION
) Introducing outdoor fresh air and discharging
arging indoor air.
air
Makes you feel comfortable as in the nature.
Shell
Electrical box
Heat exchanger
Fresh air outlet
Air filter
Lug
) Energy saving
Unique by-pass mode can reduce power consumption of fan
motor, in order to prolong lifetime of the heat exchanger core.
By the combination of heat exchange mode and by pass mode,
the unit load can be reduced about 26% in a year.
0%
Direct fresh
air introduction
Air Supply
Discharge air
20%
Independent heat
exchange process
Temp plate
26%
Heat exchange
combined with
by-pass proccess
By-pass mode
Room temperature
sensor
Exchange
air
Return
air
Exchange
air
Return
air
Outdoor
air intake
Supply
air
Outdoor
air intake
Supply
air
64
Moisture absorption
Move through capillary
Moisture release
Flexible control
LED display
Energy saving mode
24h timer
Centralized controller
Weekly timer
Long-distance Monitoring Control (optional)
Low-noise Design
Build-in low noise ventilation fan.
) Installation example
Fresh air duct
Indoor
air return
65
SPECIFICATIONS
) ERV
MODEL
Power supply
Power Input (W)
Airflow rate
Sound pressure level (dB(A))
External static pressure
Temperature exchange efficiently
Enthalpy exchange efficiency
HRVQ-D3.5-K
H/M/L
H/M/L
H/M/L
Heating (H/M/L)
Cooling (H/M/L)
m3/h
CFM
Pa
%
MODEL
Power supply
Power Input (W)
m3/h
CFM
Airflow rate
Sound pressure level (dB(A))
External static pressure
Temperature exchange efficiently
Enthalpy exchange efficiency
Dimension (WxDxH) (mm)
Net weight (Kg)
66
Pa
Heating
Cooling
165
360/260/210
212/153/124
37
100/80/60
71/73/75
65/67/68
61/63/65
800x879x306
45
HRVQ-D5-K
HRVQ-D8-K
HRVQ-D10-K
440
1000/750/600
588/441/353
46
110/85/65
75/77/79
66/68/70
62/64/65
832x1016x380
57
HRVQ-D15-M
HRVQ-D20-M
HRVQ-D30-M
600
1500
882
48
150
73
65
60
1210x1215x452
100
380~415V 3N~50Hz
950
2000
1176
50
150
71
62
58
1210x1215x452
100
2800
3000
1176
54
220
70
62
58
1340x1550x572
240
CONNECTION BRANCHES
) Modular Outdoor
Unit Branch Joint
Gas Pipe
Gas Pipe
Liquid Pipe
Liquid Pipe
Configuration
Configuration
22.4 X 96
96 < X
Configuration
X 20.0
20.0 < X 30.0
30.0 < X 70.0
70.0 < X 135.0
135.0 < X
X 5.6
5.6 < X 22
22 < X 30
30 < X 68
68 < X 96
96 < X 135
135 < X
67
No1
www.inventor.ac/tech_spec
.inventor.ac/tech_spe
ec
www.inventor.ac