Caution
Warning
Danger
No.
Accessories
6
11
12
Element
Power supply
2 connector
(PWR(V), FG)
Caution
After maintenance is complete, perform appropriate functional
inspections.
Stop operation if the equipment does not function properly.
Safety cannot be assured in the case of unexpected malfunction.
Provide grounding to assure the safety and noise resistance of
the Fieldbus system.
Individual grounding should be provided close to the product with a
short cable.
NOTE
When conformity to UL is required, the GW unit shoud be used with a
UL 1310 Class 2 power supply.
Communication port D
(COM D)
LED Display / switch
setting
1 2 3
Pin No.
1
2
Description
24 V
0V
Function
+24 VDC for controlling GW
0 V for controlling GW
Pin No.
1
2
3
Description
24 V
0V
FG
Function
+24 VDC for output
0 V for output
Functional earth
Branch connector
1 2 3 4
Pin No.
1
2
3
4
Description
24 V
TD (+)
TD (-)
0V
Function
+24 V for output unit
Transmit data (+)
Transmit data (-)
0 V for output unit
Removal
Indication
3
PWR(V)
Claw 1
Claw 2
LINK
100
2
4
MS
A
NS
1
0
1
0
1
0
1
2
0
0
1
1
1
1
3
0
0
0
0
1
1
SW2
3 4 5
0 - 1 - 1 0 1 1 1 - 0
1 - 1
6
0
0
0
0
1
1
7
0
0
0
0
1
1
8
0
0
0
0
1
1
SW2
1
0
1
X
Remote control
1
2
3
254
DHCP mode
Y
0
1
Communication
setting
Manual setting of
IP address
CLEAR / HOLD
Item
Content
Communication
setting
Communication
speed
Communication
method
Reserved
Set to OFF
IP address 192.168. Y . X
SW1
4 5
0 0
0 0
0 0
0 0
1 1
1 1
SW2
Content
6
0
The output signal is cleared when the communication error occurs.
1
The output signal is held when the communication error occurs.
For more detailed setting information refer to the operation manual for
this product.
Troubleshooting
Refer to the operation manual for this product.
LED indication
Installation
SW2
8 Mounting bracket
Description
TX+
TXRX+
RX-
Communication port A
4
(COM A)
Warning
Pin
1
2
3
4
5
6
7
8
87654321
Power supply
connector (PWR)
SW1
ON
Description
Communication port B
5
(COM B)
Connect to an SI unit (manifold valve) etc.
).
Communication port C using branch cables (EX510-FC
6
(COM C)
Select the appropriate cables to mate with the connectors mounted on the
GW unit.
10
Communication
1
connector (BUS)
Switch setting
The settings should only be made with the power supply turned OFF.
Connecting cables
Safety Instructions
Setting
Installation (Continued)
Content
OFF
Green ON
OFF
Green ON
Green flashing
OFF
Green ON
OFF
Green ON
Green flashing
Red flashing
Red ON
OFF
Green flashing
Green ON
Red flashing
Red ON
IP address duplicated
Power supply for controlling GW: 21.6 to 26.4 VDC, 200 mA or less
Power supply for output: 22.8 to 26.4 VDC
Max. 3.6 A
Connected device: EX510 series SI unit and output unit (manufactured
by SMC)
Ambient temperature for operation: -10 to 50 oC
Ambient temperature for storage: -20 to 60 oC
Pollution degree 3: (UL508)
This product is IP20 rated.
Please install in an enclosure of IP54 or more when using the product in
a pollution degree 3 environment.
For more detailed specifications and outline dimensions refer to the
operation manual for this product.
Contacts
AUSTRIA
BELGIUM
BULGARIA
CZECH REP.
DENMARK
ESTONIA
FINLAND
FRANCE
GERMANY
GREECE
HUNGARY
IRELAND
ITALY
LATVIA
LITHUANIA
NETHERLANDS
NORWAY
POLAND
PORTUGAL
ROMANIA
SLOVAKIA
SLOVENIA
SPAIN
SWEDEN
SWITZERLAND
UNITED KINGDOM
(371) 781 77 00
(370) 5 264 8126
(31) 20 531 8888
(47) 67 12 90 20
(48) 22 211 9600
(351) 21 471 1880
(40) 21 320 5111
(421) 2 444 56725
(386) 73 885 412
(34) 945 184 100
(46) 8 603 1200
(41) 52 396 3131
(44) 1908 563888