Sei sulla pagina 1di 15

LTE SIG Data Collection Based on the WebNIC

1 LTE SIG Data Collection Based on the


WebNIC
1. Log in to the WebNIC and create a subscribed data collection task that will be issued to
an eNodeB.
(1) Start the IE browser and enter http://server IP address/nic on the address bar. The
WebNIC window is displayed. The server IP address is the IP address of the M2000
client.
(2) In the WebNIC window, click the triangle icon on the right of Create Task and choose
Based on Customize Collection Item from the drop-down list.

(3) In the Task Property Settings window, enter Task name, select LTE for Product type,
and click Next.

(4) In the NEs Selection window, select an eNodeB that must carry services.

2015-5-24

Page 1 of 15

LTE SIG Data Collection Based on the WebNIC

(5) In the Collection Items Selection window, select the event subscription type (collection
items in the red rectangle, shown in the following figure). For Stop Subscribe in the
green rectangle, a stop subscribe task needs to be created.
The following table lists the events to be subscribed. Select SIG Event Subscribe in step 5
and select specific collection items for each event in step 6.

2015-5-24

Page 2 of 15

LTE SIG Data Collection Based on the WebNIC

SIG Event Subscribe

MDT Event Subscribe


MR Event Subscribe

Collection Item
UE_MR_MDT
RLF
PRIVATE_UE_POSITIONING
PRIVATE_UE_MR
PERIOD_LOGGED_MDT_MEASUREMENT

(6) In the Detailed parameters settings of collection items window, set parameters of
collection items.

2015-5-24

Page 3 of 15

LTE SIG Data Collection Based on the WebNIC

(7) In the Task Overview window, view the task information, and then click Finish.

2. Send the MML command to the eNodeB and check whether the file subscribed by the
2015-5-24

Page 4 of 15

LTE SIG Data Collection Based on the WebNIC

eNodeB is generated.
MML commandLST LOGFILE:FT=eNodeB,LT=SIGLOG;

3. Log in to the WebNIC and crease an SIG data collection task.


(1) Start the IE browser and enter http://server IP address/nic on the address bar. The
WebNIC window is displayed. The server IP address is the IP address of the M2000
client.
(2) In the WebNIC window, click the triangle icon on the right of Create Task and choose
Based on Customize Collection Item from the drop-down list.

(3) In the Task Property Settings window, enter Task name, select LTE for Product type,
and click Next.

(4) In the Detailed parameters settings of collection items window, set data collection time
and click Next.
(5) In the NEs Selection window, select an eNodeB that must carry services.
2015-5-24

Page 5 of 15

LTE SIG Data Collection Based on the WebNIC

(6) In the Collection Items Selection window, select Log collection of central-layer faults
under LTE_Logs and Alarms.

2015-5-24

Page 6 of 15

LTE SIG Data Collection Based on the WebNIC

(7) Click Next.

2015-5-24

Page 7 of 15

LTE SIG Data Collection Based on the WebNIC

(8) Click Next.

2015-5-24

Page 8 of 15

LTE SIG Data Collection Based on the WebNIC

The task is successfully created.


(9) After the task is complete, click Download in the Collection Result column to download
data to the local PC.

If the data collection fails, please check the operation log of NIC. If caused by insufficient
permissions to execute the command, please add permissions in the following step:
(1) View MML command operations of users or user group on NEs on M2000 client.
a)

Choose Security > Security Management (traditional style); alternatively, double-click

Security Management in Application Center and choose OSS Security > OSS User
Management (application style).
b)

In the Security Management navigation tree Expand the User or User Group node and

select a user or user group.


c)

On the Bound NE tab page on the right, view the NE list bound with the user or user

2015-5-24

Page 9 of 15

LTE SIG Data Collection Based on the WebNIC

group and the MML command group that can be executed on the corresponding NEs.

The NE displays the NEs on which the user or user group can run the
MML commands.

After selecting an NE in the NE area, the Command Group area


displays the MML command groups that can be executed by the user
or user group on the corresponding NEs.

d)

Check if user has the operation right of ULD LOG. If not, execute step (2) to add.

(2) On the Bound NE tab page, click NE and select NEs and the MML command groups
that can be executed on the NE. Then, click OK.
Note:
You should log in as a user in SMManagers when execute querying or adding operation on
M2000 client. If you have no related rights, please contact the related principal.

2015-5-24

Page 10 of 15

LTE SIG Data Collection Based on the WebNIC

2 LTE SIG Data Collection Based on the


WebNIC
1. Log in to the WebNIC and create a subscribed data collection task that will be issued to an
eNodeB.
(1) Start the IE browser and enter http://server IP address/nic on the address bar. The
WebNIC window is displayed. The server IP address is the IP address of the M2000
client.
(2) In the WebNIC window, click the triangle icon on the right of Create Task and choose
Based on Customize Collection Item from the drop-down list.

(3) In the Task Property Settings window, enter Task name, select LTE for Product type,
and click Next.

(4) In the NEs Selection window, select an eNodeB that must carry services.

2015-5-24

Page 11 of 15

LTE SIG Data Collection Based on the WebNIC

(5) In the Collection Items Selection window, select the event subscription type (collection
items in the red rectangle, shown in the following figure). For Stop Subscribe in the
green rectangle, a stop subscribe task needs to be created.
The following table lists the events to be subscribed. Select SIG Event Subscribe in step 5 and
select specific collection items for each event in step 6.
SIG Event Subscribe
MDT Event Subscribe

MR Event Subscribe

2015-5-24

Collection Item
UE_MR_MDT
RLF
PRIVATE_UE_POSITIONING
PRIVATE_UE_MR
PERIOD_LOGGED_MDT_MEASURE
MENT

Page 12 of 15

LTE SIG Data Collection Based on the WebNIC

(6) In the Detailed parameters settings of collection items window, set parameters of
collection items.

(7) In the Task Overview window, view the task information, and then click Finish.

2015-5-24

Page 13 of 15

LTE SIG Data Collection Based on the WebNIC

2. Send the MML command to the eNodeB and check whether the file subscribed by the
eNodeB is generated.
MML command: LST LOGFILE:FT=eNodeB,LT=SIGLOG.

3. Log in to the TS server and check whether the file subscribed by the eNodeB is uploaded to
the TS server.
(1) Ensure that the eNodeB and the TS server can be pinged.
The TS server pings the eNodeB.

The eNodeB pings the TS server.

2015-5-24

Page 14 of 15

LTE SIG Data Collection Based on the WebNIC

(2) Check the SIG file uploaded to the TS server.


Navigate to the /export/home/sysm/ftproot/SauService/rawdata/sig directory. The file
under the directory is named using the FDN of the eNodeB. The eNodeB uploads its own
SIG file to the TS server. Therefore, the file under this directory is the original file
uploaded by the eNodeB.

(3) Check the SIG file that is subscribed by the eNodeB.


Navigate to the /export/home/sysm/internalftp/var/SauService/filter/NIC directory.
The name of the file subscribed by the eNodeB under this directory starts with the FDN
of the eNodeB. The subscribed file is the SIG file, which contains LTE subscription
events, filtered out from the directory in step 2. (The SIG file is filtered out by the TS
server).

2015-5-24