Sei sulla pagina 1di 16

PVC

INSULATED

POWER
AND
CONTROL

CABLES
IS 1554
(PT 1):1988

An ISO- 9001- 2008 Accredited Company


CM/L 6358174

PVC INSULATED POWER AND CONTROL CABLES


AS PER IS: 1554 (PART - 1) 1988
SBEE have manufacturing facility at Bangalore, India with state-of-the-art machine with latest technology and faster machine speeds from wire drawing to cable testing,
from purchase to despatch. SBEE PVC insulated & sheathed cables offered with copper & aluminium conductors unarmoured and armoured with galvanized steel wire
/strip. These cables are suitable for heavy - duty power control and instrumentation application in power generation utilities, industrial distribution, chemical & fertilizer
industries & mining Installation. SBEE cables also design & manufacture cables for specialized application. These cables are marked as 1.1KV grade a per IS: 1554
(PART - 1) 1988
CONDUCTOR : The conductors of power cables are made from electrical purity aluminium, and those of control cables are of annealed high conductivity copper. Power cables with
copper conductor can also be supplied against order. All conductors conform to IS: 8130-1984

ALUMINIUM

COPPER
1.5 sq mm to 6 sq mm

10 sq mm & above

CONSTRUCTION

FLEXIBILITY

1.5 Sq. mm

Solid

Class - 1

2.5 sq mm to 10 sq mm

Solid/Stranded

Class -1 for Solid


Class -2 for Stranded

6 sq. mm & above

Stranded

Class - 2

INSULATION
High quality PVC compound applied over conductor by extrusion. General Purpose PVC insulation with maximum operating temperature of 70 degC and heat resisting
PVC with maximum operating temperature of 85 degC are used for 1.1kv cables. Heat Resistance PVC upto 105 degC can be available on request.
The Insulation and Outer sheathing compounds shall be conforming to IS: 5831 1984 as per the requirement of IS: 1554 (PART - 1) 1988.
LAYING UP OF THE CORES
In twin, three and multicore cables, the cores are laid up together with a suitable lay; the outermost Layer is having right hand lay andthe successive layers are laid with
opposite lay; where necessary, the interstices shall be filled with non - hygroscopic material.
CORE IDENTIFICATION
Colour Scheme: Cores are identified by colour scheme of PVC insulation. The following colour scheme is normally adopted:

PVC INSULATED POWER & CONTROL CABLES

a)
b)
c)
d)
e)
f)

1 Core - Red, Black, Yellow, Blue or natural (non pigmented)


2 Core - Red and Black
3 Core - Red, Yellow and Blue
4 Core - Red, Yellow, Blue & Black (Reduced Neutral core in three and half core is Black.)
5 Core - Red, Yellow, Blue, Black & Grey
6 Cores & Above - Two adjacent cores (counting and directional) in each layer are coloured blue and yellow respectively and remaining cores are Grey.
Alternatively core with number printing can be offered.
INNER SHEATH : For all cables having two or more core, extruded sheath of PVC Compound or wrapping of thermoplastic or proofed tapes applies a common covering
(Inner Sheath) over the laid up cores.
ARMOURING : For multicore cables armouring is applied over the Inner sheath. In case of cable where fictitious diameter over inner sheath does not exceed 13mm, the
armour consist of galvanized round steel wires. For single core armoured cables, non- magnetic armouring is provided over the insulation. The direction of lay of armour
is left hand in case of double armoured wire. This requirement is applicable to inner layer of armouring, the outer layer of armour is applied with right hand lay and there is
a separator of PVC tape between the layer of armour strip wires.
OUTER SHEATH : Outer sheath is extruded over the armouring. In case of multi-core unarmoured cables, it is extruded over the laid up cores.
For unarmoured single core cables, it is extruded over the insulation. This is always black in colour for best resistance to outdoor exposure. Any other colour can be
Available on request.
IDENTIFICATION : Our brand name SBEE along with voltage is embossed on the outer sheath through out the length of the cable at regular intervals, Cables with heat
resisting PVC insulation are identified by letters HR embossed on the outer sheath; Our brand SBEE, Voltage Grade, Cross Sectional Area, year of manufacturing &
number of core are printed on the drums.
CABLE CODE : As per IS: 1554 (part -1) 1988, the product is coded by alphabets.
Aluminium
A
PVC Insulation
Y
Steel Round Wire Armour
W
Steel strip Armour
F
Steel Double Round Wire Armour
WW
Steel Double strip Armour
FF
PVC Outer Sheath
Y
Aluminium Wire Armour
AW
No code letter is required when conductor material is copper. This product code is stenciled on the surface of the drum flange.
FRLS CABLES : In the recent past, the growing awareness of hazards due to fire incidence in power plants, high rise buildings, cable galleries etc, had resulted in the
development of FRLS cables. The characteristics of FRLS cable are the following:1
2
3

Flame Retardance
Low Smoke Emission
Low Acid Gas Emission

2 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

Cable Manufacturing Process


COPPER/ALUMINIUM
WIRE ROD

DRAWING
TEST ON WIRE
CONDUCTOR STRANDING
PROCESS
TEST ON
STRANDED CONDUCTOR

TEST

EXTRUSION OFPVC INSULATION

TEST ON CORES

TEST ON
PVC Compound

LAYING UP OF CORES (for multi core calbes)


INNER SHEATHING (lapping of PVC tapes or extrusion of PVC)

ARMOURING WIRES/STRIPS
TEST ON
PVC tape/
PVC compound

EXTRUSION OF OUTER
SHEATHING
SINGLE CORE
UNARMOURED
CABLE

MULTI CORE
UNARMOURED
CABLE

TEST OF
FINISHED
CABLE/CUSTOMER
INSPECTION
SEALING OF
BOTH ENDS OF CABLE

SINGLE CORE
UNARMOURED
CABLE

IS 1554

PACKING
TEST ON
PVC COMPOUND

DESPATCH

As per

(PT 1):1988

TEST ON
ARMOUR WIRES/STRIPS

MARKET SEGMENT

PRIME SBEES

OTHER RANGE OF PRODUCTS

l Single and Multicore building wires with FRLS, HRFR, ZHFR, ZOFR Insulation
l Single core and Multicore cables upto 3.3 KV, XLPE/PVC insulated aluminium power
cables upto 4 cores and copper control cables upto 100 cores with armoured and unarmoured conf to is 7098:1988 & IS 1554: 1998 (part 1) standards.
l L.V. aerial branched cables upto 3.3 KV range
l Single and Multicore copper flexible cables for industrial use.
l Signal and Instrumentation cables with Aluminium and copper screening with ATC
braiding, Armoured and Un-armoured upto 100 pairs/traids
l Submersible flat cables and winding wires.
l Special cables as per customer requirement/design.
l Cables & wires as per UL & CUL recognition of AWM Style No. 1007, 1015, 1569,
1032, 2464, 2129
l Airports

l Ordinance Factories & Defence Installations

l Automobile

l Petrochemical Industries / LPG Plants

l Building & Construction Industries


l Cement Industries
l Chemical & Process Industries
l Fertilizer Industries
l Hydro Power Generation

l Petroleum Refineries & Port Terminals


l Power Electricity Distribution Industries
l Railways
l Steel Plants & Industries

l Information Technology Industries

l Thermal Power Generation

l Mining

l Turnkey Electrical Contractors

l Nuclear Power Generation

l Wind Power Generation

3 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

TABLE 1
CONDUCTOR DATA
IS:1554 PART-1 - 1988 CONDUCTOR DATA, COPPER & ALUMINIUM CONDUCTOR
FOR SINGLE CORE & MULTICORE CABLES CONFIRMING TO IS: 8130 (1984)
MINIMUM NUMBER OF WIRES IN THE
STRANDED CONDUCTOR (CLASS - 2)

NOMINAL
CROSS
SECTIONAL
AREA

CIRCULAR CONDUCTOR
(NON COMPACTED)

Sqmm

COPPER

ALUMINIUM

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

3
3
7
7
7
7
7
7
19
19
19
37
37
37
61
61
61
61
91
91
91

3
3

MAXIMUM DC RESISTANCE
AT 20 deg C

_
_
_
_

3
3
7
7
7
7
19
19
19
37
37
37
37
61
61
61
91
91
91

6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53

ALUMINIUM
CONDUCTOR
Ohm/km

PLAIN COPPER
CONDUCTOR
Ohm/km

CIRCULAR COMPACTED
OR SHAPED CONDUCTOR
ALUMINIUM
COPPER
_
_
_
_
_

18.1
12.1

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283
0.0221
0.0176

6
6
6
6
12
15
15
15
30
30
30
53
53
53
53
53

7.41
4.61
3.08
1.91
1.2
0.868
0.641
0.443
0.32
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.0367
0.0291

TABLE 2

PVC INSULATED POWER & CONTROL CABLES

CONDUCTOR RESISTANCE
IS :1554 PART1 - 1988 CALCULATED VALUE OF A.C.RESISTANCE OF CONDUCTOR (Ohm/km)
AT MAXIMUM OPERATING CONDUCTOR TEMPERATURE
Nominal Cross
Sectional Area

Sqmm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

PVC Cables (70 degC)


ALUMINIUM
21.72
14.52
8.892
5.530
3.696
2.292
1.440
1.042
0.769
0.532
0.384
0.304
0.248
0.197
0.152
0.122
0.0934
0.0726
0.0563

HR PVC Cables (85 degC)


COPPER
14.52
8.892
5.532
3.696
2.196
1.380
0.873
0.629
0.465
0.322
0.232
0.184
0.150
0.119
0.0904
0.0721
0.0664
0.0439
0.0339

ALUMINIUM
22.81
15.25
9.34
5.81
3.88
2.41
1.51
1.09
0.808
0.559
0.404
0.318
0.259
0.209
0.159
0.126
0.098
0.076
0.059

4 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

COPPER
15.25
9.34
5.81
3.88
2.31
1.45
0.916
0.661
0.488
0.338
0.244
0.193
0.156
0.129
0.095
0.076
0.059
0.046
0.0356

TABLE 3

REACTANCE & CAPACITANCE


IS :1554 PART1 - 1988 APPROXIMATE REACTANCEAT 50HZ (OHM/KM) AND
CAPACITANCE (MICRO FARADS/KM) 1.1KV PVC AND HR PVC CABLES
REACTANCE

Nominal
Area of
Conductor

PVC AND HR PVC CABLES


SINGLE CORE

Sqmm

Unarmoured

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

0.157
0.145
0.136
0.128
0.118
0.110
0.107
0.106
0.0973
0.0924
0.090
0.088
0.0862
0.0857
0.0837
0.0828
0.0810
0.0807
0.0803
0.0782
0.0772

CAPACITANCE
MULTICORE

Armoured
_
_
_
_

0.11
0.106
0.102
0.0962
0.0908
0.0859
0.0849
0.0823
0.0765
0.0769
0.0766
0.0741
0.0743
0.0742
0.0737
0.0733
0.0729
0.0732
0.0731
_
_

0.137
0.128
0.122
0.116
0.110
0.107
0.103
0.0989
0.0960
0.0950
0.0929
0.0922
0.0893
0.0890
0.0876
0.0862
0.0849

Nominal
Area Of
Conductor
sq.mm

PVC AND HR PVC CABLES


SINGLE CORE
Unarmoured

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

TWO CORE

Armoured
_
_
_
_

0.43
0.52
0.57
0.67
0.83
0.97
1.0
1.15
1.26
1.32
1.36
1.49
1.52
1.47
1.54
1.60
1.70
1.63
1.64
1.87
2.05

0.12
0.13
0.14
0.16
0.18
0.19
0.22
0.24
0.24
0.26
0.26
0.28
0.28
0.28
0.28
0.29
0.29
0.29
0.29
_
_

0.67
0.80
0.83
0.95
0.95
1.12
1.17
1.28
1.32
1.30
1.37
1.40
1.50
1.46
1.45
1.65
1.76

THREE,
THREE&
HALF AND
FOUR CORE
0.35
0.41
0.46
0.52
0.63
0.82
0.86
0.98
1.00
1.16
1.18
1.31
1.28
1.30
1.34
1.37
1.43
1.41
1.42
_
_

TABLE 4

Nominal
Area
of
Conductor

UNARMOURED - AYY
Form of
Conductor

Sqmm
4
4
6
6
10
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

So. Ci.
St. Ci.
So. Ci.
St. Ci.
So. Ci.
St. Ci.
Co. Ci.
Co. Ci.
Co. Ci.
Co. Ci.
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci
Co. Ci

Appx.
Nominal Nominal
Thickness Thickness Overall
Of
of Outer Diameter
of cable
Insulation Sheath
(mm)

(mm)

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
3.0
3.4
3.4
3.4

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.4
2.4
2.6

(mm)
8.5
8.8
9.0
9.2
10.0
10.5
11.0
12.5
13.5
15.1
16.5
18.7
21.2
22.4
24.5
27.4
30.1
34.0
37.6
42.4
48.0
52.1

Appx.
Weight
of Cable

Nominal
Thickness
of
Insulation
of
Armoured
Cable

AL ROUND WIRE ARMOURED - AYWAY


Nominal

Minimum

Diameter Thickness

AL FLAT ARMOURED - AYFAY

Appx.

Appx.

Nominal

Minimum

Normal

Appx.

Appx.

Delivery

Overall

Weight

Dimension

Thickness

Overall

Weight

Length

of Round

of Outer

Diameter

of

of Flat

of Outer

Diameter

of

(mtrs)

Wire

Sheath

of cable

Cable

Strip

Sheath

of cable

Cable

(mm)

(mm)

(mm)

(kg/km)

(kg/km)

(mm)

(mm)

(mm)

(mm)

(kg/km)

76
80
88
92
109
115
145
197
240
301
392
505
620
749
896
1115
1356
1754
2158
2671
3278
3964

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.5
1.5
1.7
1.7
1.9
1.9
2.1
2.3
2.5
2.7
3.0
3.4
3.9
3.9
3.9

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5

1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.72
1.88
1.88
2.04

10.5
10.9
11.5
11.7
13
12.9
13.8
15.5
16.5
18.2
20.2
22.7
24.0
25.7
28.2
31.4
33.9
38.2
42.4
47.4
52.5
57.5

215
226
240
255
182
192
359
225
333
406
512
672
766
897
1065
1321
1570
2020
2513
3160
3781
4685

4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80

1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.72
1.88
2.04

21.5
23.0
24.5
27.0
30.0
32.7
36.7
40.7
45.7
50.5
54.5

So.Ci= Solid Circular, St.Ci=Stranded Circular, Co.Ci=Compacted Circular, St.Sh= Stranded Shaped

5 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

595
676
808
962
1190
1452
1717
2230
2844
3466
4193

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500

PVC INSULATED POWER & CONTROL CABLES

DIMENSIONS AND WEIGHTS


'SBEE' 1.1KV SINGLECORE PVC INSULATED UNARMOURED AND ARMOURED CABLE
WITH ALUMINIUM CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988

TABLE 5
DIMENSIONS AND WEIGHTS
IS :1554 PART1 - 1988 DIMENSIONS AND WEIGHTS 1100VOLTS TWO CORE PVC INSULATED
UNARMOURED AND ARMOURED WITH ALUMINIUM CONDUCTOR
Nominal
Area
of
Conductor

UNARMOURED - AYY
Appx.
Nominal Nominal Nominal
Thickness Thickness Thickness Weight
Of
of Outer of Outer of Cable
Sheath
Insulation Sheath

Form of
Conductor

Sqmm
4
4
6
6
10
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

So. Cr.
St. Cr.
So. Cr.
St. Cr.
So. Cr.
St. Cr.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.

Nominal
Thickness
of
Insulation
of
Armoured
Cable

ROUND WIRE ARMOURED - AYWY


Nominal

Minimum

Diameter Thickness

FLAT ARMOURED - AYFY

Appx.

Appx.

Nominal

Minimum

Normal

Appx.

Appx.

Delivery

Overall

Weight

Dimension

Thickness

Overall

Weight

Length

of Round

of Outer

Diameter

of

of Flat

of Outer

Diameter

of

(mtrs)

Wire

Sheath

of cable

Cable

Strip

Sheath

of cable

Cable

(mm)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(mm)

(kg/km)

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
3.0
3.4

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.5
0.5
0.6
0.7
0.7
0.7
0.7

1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.2
2.2
2.4
2.4
2.6
2.8
3.2
3.4
3.8

13.5
14.0
14.5
15.0
16.0
17.0
19.0
20.0
21.5
24.0
26.5
31.0
32.5
36.5
40.0
44.0
50.0
56.0
65.0
73.5

200
241
250
274
300
338
413
430
506
650
810
1156
1329
1638
2016
2540
3090
3973
4989
6355

1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5
2.5
3.15
3.15
4.0

1.24
1.24
1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.2
2.52
2.84
3.0

14.5
15.0
16.0
16.5
17.5
18.0
21.0
22.5
24.0
26.7
29.3
33.7
36.2
39.5
43.5
48.7
54.2
62.5
71.5
81.5

474
537
550
520
640
660
842
935
1091
1290
1473
2113
2364
2766
2326
4360
5060
6921
8291
11093

4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8

1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.72
1.88
2.04
2.2
2.36
2.68
2.84

19.5
21.0
22.0
25.0
27.5
31.5
33.0
37.0
41.0
45.5
50.5
57.0
66.0
73.0

510
700
769
964
1192
1585
1781
2106
2588
3188
3776
4725
5872
7278

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500
500

So.Ci= Solid Circular, St.Ci=Stranded Circular, Co.Ci=Compacted Circular, St.Sh= Stranded Shaped

TABLE 6

PVC INSULATED POWER & CONTROL CABLES

'SBEE' 1.1KV THREE CORE PVC INSULATED UNARMOURED AND ARMOURED CABLE
WITH ALUMINIUM CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988
UNARMOURED - AYY
Nominal
Area
of
Conductor

Form of
Conductor

Sqmm
4
4
6
6
10
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

So. Cr.
St. Cr.
So. Cr.
St. Cr.
So. Cr.
St. Cr.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.
St. Sh.

Nominal
Thickness
Of
Insulation

Nominal Nominal
Thickness Thickness
of Inner
of Outer
Sheath
Sheath

ROUND WIRE ARMOURED - AYWY

Appx.
Overall
Diameter
of cable

Appx.
Weight
of Cable

FLAT STRIP ARMOURED - AYFY

of Round

of Outer

Diameter

of

of Flat

of Outer

Diameter

Appx. Normal
Weight Delivery
Length
of

Wire

Sheath

of cable

Cable

Strip

Sheath

of cable

Cable

(mm)

(mm)

(mm)

(kg/km)

Minimum

Appx.

Appx.

Nominal

Minimum

Appx.

Diameter Thickness

Overall

Weight

Dimension

Thickness

Overall

Nominal

(mm)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(kg/km)

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
3.0
3.4

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.5
0.5
0.6
0.6
0.7
0.7
0.7

1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.2
2.2
2.2
2.4
2.6
2.8
3.0
3.4
3.6
4.0

14.0
15.5
15.5
16.5
17.0
18.0
18.0
21.0
23.0
26.0
29.0
34.0
37.0
41.0
45.0
50.9
56.0
63.4
72.5
82.0

220
268
275
300
340
353
384
554
681
850
1122
1473
1720
2258
2660
3401
4150
5319
6653
8537

1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5
2.5
2.5
3.15
3.15
4.0

1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.72
1.72
1.88
2.04
2.2
2.36
2.68
3.0
3.0

17.5
17.7
18.5
18.8
20.5
21.0
21.2
24.0
26.2
29.6
33.3
37.7
40.5
44.0
49.5
55.0
60.5
69.0
79.5
89.5

525
576
590
642
714
767
838
1060
1226
1511
2056
2510
2007
3439
4441
5403
6348
8485
10388
13806

4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8

1.4
1.4
1.4
1.56
1.56
1.56
1.72
1.88
1.88
2.20
2.36
2.52
2.84
3.00

19.5
22.3
24.0
27.9
30.9
34.8
37.8
41.9
45.7
52.0
56.8
64.0
73.0
83.0

So.Ci= Solid Circular, St.Ci=Stranded Circular, Co.Ci=Compacted Circular, St.Sh= Stranded Shaped

6 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

643
837
976
1230
1520
1947
2248
2700
3234
4063
4883
6071
7641
9580

(mtrs)

1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500
500
500
250
250

TABLE 7

DIMENSIONS AND WEIGHTS


'SBEE' 1.1KV THREE AND A HALF CORE PVC INSULATED UNARMOURED AND ARMOURED CABLE
WITH ALUMINIUM CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988

Nominal
Area
of
Conductor
Power
Core/
Neutral
Core

Nominal
Thickness
of Insulation

Thickness

Power Neutral

of Inner

Minimum

Sheath
Core

Core

Sqmm

mm

mm

25/16
35/16
50/25
70/35
95/50
120/70
150/70
185/95
240/120
300/150
400/185
500/240
630/300

1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
3.0
3.4

1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4

Nominal
Appx.
Thickness Overall
of Outer Diameter
Sheath
of cable

FLAT STRIP ARMOURED - AYFY

ROUND WIRE ARMOURED - AYWY

UNARMOURED - AYY

Appx.
Weight
of Cable

Nominal

Minimum

Minimum

Appx.

Appx.

Normal

Weight Dimension Thickness

Appx.

Overall

Weight

Delivery

Appx.

Diameter Thickness Overall

of

of Flat

of Outer

Diameter

of

Length

Wire

Sheath

of cable

Cable

Strip

Sheath

of cable

Cable

(mtrs)

of Round

of Outer Diameter

Nominal

(mm)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(kg/km)

0.3
0.3
0.3
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7

2.0
2.0
2.0
2.2
2.2
2.4
2.4
2.6
3.0
3.2
3.4
3.8
4.0

23.8
25.3
28.5
32.9
36.5
39.8
44.0
48.0
55.0
61.0
68.0
79.0
89.0

657
787
1052
1325
1720
2110
2470
3026
3975
4805
6110
7748
9797

1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5
2.5
3.15
3.15
4.0
4.0

1.4
1.4
1.56
1.56
1.72
1.88
1.88
2.04
2.36
2.52
2.68
3.0
3.0

26.0
27.8
32.0
36.1
40.5
43.5
47.8
52.8
59.6
66.5
74.0
87.0
95.5

1200
1364
1711
2335
2881
3364
3890
4997
6159
8003
9562
12990
15665

4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8

1.4
1.4
1.56
1.56
1.56
1.72
1.88
2.04
2.2
2.36
2.68
2.84
3.0

24.2
26.1
29.4
33.5
37.0
40.3
45.5
49.0
55.4
61.0
68.9
80.0
90.5

950
1091
1471
1755
2192
2619
3100
3745
4649
5625
6950
8785
10948

500
500
500
500
500
500
500
500
500
500
500
250
250

So.Ci= Solid Circular, St.Ci=Stranded Circular, Co.Ci=Compacted Circular, St.Sh= Stranded Shaped

TABLE 8

WITH ALUMINIUM CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988


UNARMOURED - AYY
Nominal
Area
of
Conductor

Form of
Conductor

sq.mm
4
4
6
6
10
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

So.Ci.
St.Ci.
So.CI.
St.Ci.
So.Ci.
St.Ci
St.Sh.
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh
St.Sh

ROUND WIRE ARMOURED - AYWY


Appx.

Appx.

Nominal

Minimum

Appx.

Appx.

Normal

Diameter Thickness

Overall

Weight

Dimension

Thickness

Overall

Weight

Delivery

Diameter

of

of Flat

of Outer

Diameter

of

Length

of cable

Cable

Strip

Sheath

of cable

Cable

(mtrs)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(kg/km)

1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.72
1.88
2.04
2.2
2.36
2.68
2.84
3.0
3.0

18.5
18.9
20.0
20.3
22.5
22.8
23.9
26.4
28.9
33.7
37.0
42.0
45.5
50.4
56.5
62.2
70.0
77.4
90.0
101.0

590
655
680
735
880
910
1002
1245
1493
2079
2435
3139
3645
4725
5603
6758
8874
10576
14152
17258

Appx.
Weight
of Cable

(mm)

(mm)

(kg/km)

(mm)

1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.2
2.2
2.4
2.4
2.6
2.8
3.0
3.4
3.6
4.0
4.0

16.5
16.8
17.5
17.7
19.5
19.8
21.1
24.2
26.4
30.7
34.0
39.0
42.0
46.5
52.5
58.0
65.0
72.0
84.0
84.5

260
300
320
367
400
456
511
695
831
1150
1437
1945
2310
2820
3520
4535
5695
6875
8243
11087

1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
3.15
3.15
4.0
4.0

Nominal
Thickness
of Inner
Sheath

Nominal
Thickness
of Outer
Sheath

(mm)

(mm)

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.8
3.0
3.4

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.5
0.5
0.6
0.6
0.7
0.7
0.7
0.7

FLAT STRIP ARMOURED - AYFY

Minimum

Appx.
Overall
Diameter
of cable

Nominal
Thickness
Of
Insulation

Nominal
of Round

of Outer

Wire

Sheath

4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8
4.0x0.8

1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.72
1.88
1.88
2.04
2.36
2.52
2.84
3.0
3.0

21.0
21.2
22.4
24.9
27.0
31.2
34.5
39.5
43.0
47.0
52.3
58.9
65.0
72.5
84.0
94.5

So.Ci= Solid Circular, St.Ci=Stranded Circular, Co.Ci=Compacted Circular, St.Sh= Stranded Shaped

7 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

680
738
770
1024
1190
1550
1911
2420
2881
3421
4166
5224
6430
7800
9849
12308

1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500
500
500
250
250

PVC INSULATED POWER & CONTROL CABLES

DIMENSIONS AND WEIGHTS


'SBEE' 1.1KV FOUR CORE PVC INSULATED UNARMOURED AND ARMOURED CABLE

TABLE 9

DIMENSIONS AND WEIGHTS

'SBEE' 1.1KV 1.5Sq.mm (SOLID) PVC INSULATED UNARMOURED AND ARMOURED


MULTICORE CONTROL CABLE WITH COPPER CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988
Number

Nominal

of

Thickness

Cores

of

2
3
4
5
6
7
8
9
10
12
14
16
19
21
24
27
30
33
37
44
52
61

Minimum

UNARMOURED - AYY

ROUND WIRE ARMOURED - AYWY

FLAT STRIP ARMOURED - AYFY

Normal

Thickness
of
Inner

Insulation

Sheath

mm

(mm)

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4

Appx.
Appx.
Appx. Nominal Minimum
Appx.
Nominal
Thickness Overall Weight Diameter Thickness Overall Weight
of
of Outer Diameter of Cable of Round of Outer Diameter
Sheath of cable Cable
Wire
Sheath of cable
(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(mm)

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2

11.5
12.0
13.0
14.0
15.0
15.0
16.0
17.0
18.0
18.5
19.0
20.0
21.5
22.5
24.5
25.0
26.0
27.0
28.0
31.0
33.0
34.5

150
170
200
239
261
271
312
353
388
416
466
521
600
670
750
810
890
907
1050
1280
1464
1678

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0

1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56

14.0
14.5
15.5
16.0
17.0
17.0
18.0
19.0
20.5
21.5
22.5
23.5
24.0
25.5
27.5
28.0
28.5
29.5
30.5
34.0
36.5
38.0

357
390
446
490
530
540
608
670
726
850
919
1006
1091
1184
1309
1393
1498
1589
1711
1998
2446
2734

Appx.
Nominal Minimum Appx.
Dimension Thickness Overall Weight
of
of Outer Diameter
of Flat
Strip

Sheath

of cable

Cable

(mm)

(mm)

(mm)

(kg/km)

4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80

1.24
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56

19.5
21.0
21.5
22.5
23.5
25.5
26.0
27.0
28.0
29.0
32.5
34.0
36.0

631
709
776
866
937
1058
1135
1221
1310
1421
1677
1903
2148

Delivery
Length
(Mtrs)

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500

PVC INSULATED POWER & CONTROL CABLES

TABLE 10
'SBEE' 1.1KV 1.5Sq.mm ( STRANDED) PVC INSULATED UNARMOURED AND ARMOURED
MULTICORE CONTROL CABLE WITH COPPER CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988
Number

Nominal

of

Thickness

Cores

of

2
3
4
5
6
7
8
9
10
12
14
16
19
21
24
27
30
33
37
44
52
61

Minimum

UNARMOURED - AYY

ROUND WIRE ARMOURED - AYWY

FLAT STRIP ARMOURED - AYFY

Normal

Thickness
of
Inner

Insulation

Sheath

mm

(mm)

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4

Appx. Nominal
Appx.
Nominal
Thickness Overall Weight Diameter
of Outer Diameter of Cable of Round
Wire
Sheath of cable

Appx.

Appx.

Thickness Overall

Weight

Minimum

of Outer Diameter

of

Appx.
Nominal Minimum Appx.
Dimension Thickness Overall Weight
of
of Outer Diameter
of Flat

Sheath

of cable

Cable

Strip

Sheath

of cable

Cable

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(kg/km)

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2

12.0
12.5
13.5
14.5
15.5
15.5
16.5
17.5
19.0
19.5
20.0
21.0
22.5
23.5
26.0
26.5
27.5
28.0
29.0
32.5
34.5
36.0

164
189
222
262
279
290
334
379
393
443
498
558
650
717
801
875
952
1037
1133
1329
1570
1799

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0

1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56

14.5
15.0
16.0
16.5
18.0
18.0
19.0
20.0
21.5
22.5
23.5
24.0
25.5
26.5
28.5
29.0
30.0
31.0
32.0
35.5
38.0
40.0

378
415
471
535
576
587
654
722
777
896
983
1059
1164
1262
1409
1498
1591
1706
1818
2134
2626
2963

4.0x0.80
4.0X0.80
4.0X0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80

8 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

1.24
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56

20.5
21.5
22.5
23.5
25.0
27.0
27.5
28.5
29.5
30.5
34.0
35.5
37.5

www.sbeecables.in

667
748
819
912
987
1115
1195
1285
1378
1494
1764
2046
2257

Delivery
Length
(Mtrs)

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500

TABLE 11

DIMENSIONS AND WEIGHTS


'SBEE' 1.1KV 2.5Sq.mm (SOLID) PVC INSULATED UNARMOURED AND ARMOURED
MULTICORE CONTROL CABLE WITH COPPER CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988
Minimum

Nominal

Number
of

Thickness

Cores

of

UNARMOURED - AYY

ROUND WIRE ARMOURED - AYWY

FLAT STRIP ARMOURED - AYFY

of
Inner

Appx.
Appx.
Appx. Nominal Minimum
Appx.
Nominal
Thickness Overall Weight Diameter Thickness Overall Weight
of
of Outer Diameter of Cable of Round of Outer Diameter
Sheath of cable Cable
Wire
Sheath of cable

Insulation

Sheath

mm

(mm)

(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(mm)

0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2

13.0
13.5
14.5
15.5
16.5
16.5
18.0
19.0
20.5
21.5
22.5
23.5
24.5
26.0
28.5
29.0
30.0
31.0
32.5
36.0
38.0
40.0

200
234
281
331
356
374
434
492
510
600
680
760
860
950
1060
1160
1260
1400
1588
1866
2150
2472

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0

1.24
1.24
1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72

15.0
15.5
16.5
18.0
19.0
19.0
20.5
22.5
23.5
24.0
25.0
26.0
27.5
28.5
31.5
32.0
33.0
34.0
36.0
40.0
42.0
44.0

438
483
550
620
676
694
795
946
998
1050
1153
1310
1404
1569
1736
1858
1996
2165
2550
2960
3328
3738

2
3
4
5
6
7
8
9
10
12
14
16
19
21
24
27
30
33
37
44
52
61

Normal

Thickness
Appx.
Nominal Minimum Appx.
Dimension Thickness Overall Weight
of
of Outer Diameter
of Flat
Sheath

of cable

Cable

(mm)

(mm)

(kg/km)

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.56
1.56
1.56

20.5
22.0
21.0
22.0
23.0
25.0
27.0
29.5
30.0
31.5
32.5
34.0
37.5
39.0
41.5

726
779
863
955
1052
1183
1284
1452
1568
1716
1847
2032
2374
2685
3050

Length
(Mtrs)

Strip
(mm)

4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80

Delivery

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500

'SBEE' 1.1KV 2.5Sq.mm (STRANDED) PVC INSULATED UNARMOURED AND ARMOURED


MULTICORE CONTROL CABLE WITH COPPER CONDUCTOR CONFORMING TO IS : 1554 PART 1 -1988
Number

Nominal

of

Thickness

Cores

of

of
Inner

Insulation
mm
2
3
4
5
6
7
8
9
10
12
14
16
19
21
24
27
30
33
37
44
52
61

Minimum

0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

UNARMOURED - AYY

ROUND WIRE ARMOURED - AYWY

FLAT STRIP ARMOURED - AYFY

Normal

Thickness

Sheath
(mm)
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4

Appx.
Nominal Minimum Appx.
Appx.
Appx.
Nominal
Weight
Overall
Thickness
Diameter
Thickness Overall Weight
of
of Outer Diameter of Cable of Round of Outer Diameter
Sheath of cable Cable
Wire
Sheath of cable
(mm)

(mm)

(kg/km)

(mm)

(mm)

(mm)

(mm)

1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2

13.5
14.0
15.0
16.0
17.5
17.5
18.5
20.0
21.5
22.5
23.5
24.5
26.0
27.0
29.5
30.5
31.5
32.0
34.5
38.5
40.0
42.5

210
246
294
347
373
390
451
514
533
628
708
790
895
1001
1111
1222
1338
1454
1653
1944
2243
2585

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0

1.24
1.24
1.24
1.24
1.24
1.24
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72

15.5
16.0
17.5
18.5
19.5
19.5
21.5
23.0
24.5
25.0
26.0
27.5
28.5
30.0
33.0
33.5
34.5
35.5
38.0
42.0
44.0
46.5

447
507
579
655
704
721
835
960
1030
1125
1214
1328
1479
1620
1828
1956
2101
2251
2684
3111
3502
3929

Appx.
Nominal Minimum Appx.
Dimension Thickness Overall Weight
of
of Outer Diameter
of Flat
Strip

Sheath

of cable

Cable

(mm)

(mm)

(mm)

(kg/km)

4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80
4.0x0.80

9 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.56
1.56
1.56
1.56
1.56
1.56

21.5
23.0
23.5
24.5
25.5
27.0
28.0
31.0
31.5
33.0
34.0
35.5
39.5
41.0
43.5

www.sbeecables.in

764
821
908
1005
1106
1244
1349
1527
1649
1803
1941
2135
2450
2740
3140

Delivery
Length
(Mtrs)

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
500
500
500

PVC INSULATED POWER & CONTROL CABLES

TABLE 12

TABLE 13

14 TABLE
CURRENT RATING

IS : 1554 PART - 1 -1988


CONTINUOUS CURRENT RATING FOR TWO SINGLE CORE,
650/1100 V UNARMOURED OR NON - MAGNETIC PVC CABLES
Laid Direct in the
Ground

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Sqmm

Amps

Amps

Amps

Amps

Amps

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

25
35
46
57
75
94
125
150
180
220
265
300
340
380
420
465
500
540
590
645
705

21
28
36
44
59
75
97
120
145
170
205
230
265
300
335
370
410
435
485
530
580

23
31
42
54
72
92
120
140
165
200
230
255
280
305
340
370
405
430
465
505
555

19
25
33
42
56
71
93
110
130
155
180
200
220
240
270
295
335
355
395
430
470

24
32
43
54
72
92
125
155
190
235
275
310
345
390
445
500
570
610
680
780
900

Laid Direct in the


Ground

Aluminum

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

Amps

Sqmm

Amps

Amps

Amps

Amps

Amps

Amps

18
25
32
41
56
72
99
120
150
185
215
240
270
305
350
395
455
490
560
640
740

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

22
30
39
49
65
85
110
130
155
190
220
250
280
305
345
375
400
425
470
530
590

17
24
31
39
51
66
86
100
120
140
175
195
220
240
270
295
325
345
390
440
490

21
29
38
48
64
83
110
125
150
175
200
220
245
260
285
310
335
355
375
410
450

17
24
30
37
51
65
84
100
115
135
155
170
190
210
225
245
275
295
320
350
385

20
27
35
44
60
82
110
130
165
205
245
280
320
370
425
475
550
590
660
770
865

15
21
27
35
47
64
84
105
130
155
190
220
250
290
335
380
435
480
550
640
720

In the Air

In Ducts

IS : 1554 PART - 1 -1988


CONTINUOUS RATINGS FOR THREE SINGLE CORE,
650/1100 V, UNARMOURED OR NON - MAGNETIC ARMOURED PVC CABLES
In the Air

In Ducts

TABLE 15

16 TABLE

PVC INSULATED POWER & CONTROL CABLES

IS : 1554 PART - 1 -1988 CURRENT RATINGS


FOR TWIN CORE,650/1100V ARMOURED OR
UNARMOURED PVC CABLES
Laid Direct in the
Ground

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Sqmm

Amps

Amps

Amps

Amps

Amps

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

23
32
41
50
70
90
115
140
165
205
240
275
310
350
405
450
490
520
565

18
25
32
40
55
70
90
110
135
160
190
210
240
275
320
355
385
415
460

20
27
35
44
58
75
97
120
145
180
215
235
270
300
345
385
425
460
510

16
21
27
34
45
58
76
92
115
140
170
190
210
240
275
305
345
365
405

20
27
35
45
60
78
105
125
155
195
230
265
305
350
410
465
530
575
655

IS : 1554 PART - 1 -1988 CURRENT RATINGS FOR THREE,


THREE AND A HALF AND FOUR CORE, 650/1100V
ARMOURED OR UNARMOURED PVC CABLES
Laid Direct in the
Ground

Aluminum

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

Amps

Sqmm

Amps

Amps

Amps

Amps

Amps

Amps

16
21
27
35
47
59
78
99
125
150
185
210
240
275
325
365
420
455
520

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

21
27
36
45
60
77
99
120
145
175
210
240
270
300
345
385
425
470
515

16
21
28
35
46
60
76
92
110
135
165
185
210
235
275
305
335
370
405

17
24
30
38
50
64
81
99
125
150
175
195
225
255
295
335
360
405
445

14
18
23
30
39
50
63
77
95
115
140
155
175
200
235
260
290
320
350

17
24
30
39
52
66
90
110
135
165
200
230
265
305
355
400
455
540
610

13
18
23
30
40
51
70
86
105
130
155
180
205
240
280
315
375
425
480

In the Air

In Ducts

10 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

In the Air

In Ducts

www.sbeecables.in

TABLE 17

18 TABLE
CURRENT RATING

IS : 1554 PART - 1 -1988 CURRENT RATINGS


FOR TWO SINGLE CORE, 650/1100 V UNARMOURED OR
NON - MAGNETIC ARMOURED HRPVC CABLES
Laid Direct in the
Ground

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Sqmm

Amps

Amps

Amps

Amps

Amps

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

29
40
52
65
86
107
143
171
205
251
302
342
388
433
479
530
570
616
673
735
804

24
32
41
50
67
86
111
137
165
194
234
262
302
342
382
422
467
496
553
604
661

26
35
48
62
82
105
137
160
188
228
262
291
319
348
388
422
462
490
530
576
633

22
29
38
48
64
81
106
125
148
177
205
228
251
274
308
336
382
405
450
490
536

29
38
52
65
86
110
150
186
228
282
330
372
414
468
534
600
684
732
816
936
1080

IS : 1554 PART - 1 -1988 CURRENT RATINGS


FOR THREE SINGLE CORE, 650/1100 VOLTS UNARMOURED OR
NON - MAGNETIC ARMOURED HR PVC CABLE
Laid Direct in the
Ground - HR PVC

Aluminum

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

Amps

Sqmm

Amps

Amps

Amps

Amps

Amps

Amps

22
30
38
49
67
86
119
144
180
222
258
288
324
366
420
474
546
588
672
768
888

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

25
34
44
56
74
97
125
148
177
217
251
285
319
348
393
428
456
485
536
604
673

19
27
35
44
58
75
98
114
137
160
200
222
251
274
308
336
371
393
445
502
559

24
33
43
55
73
95
125
143
171
200
228
251
279
296
325
353
382
405
428
467
513

19
27
34
42
58
74
96
114
131
154
177
194
217
239
257
279
314
336
365
399
439

24
32
42
53
72
98
132
156
198
246
294
336
384
444
510
570
660
708
792
924
1038

18
25
32
42
56
77
101
126
156
186
228
264
300
348
402
456
522
576
660
768
864

In the Air

In Ducts

In the Air

In Ducts

TABLE19

20 TABLE

Laid Direct in the


Ground

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Sqmm

Amps

Amps

Amps

Amps

Amps

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

26
36
47
57
80
103
131
160
188
234
274
314
353
399
462
513
559
593
644

21
29
36
46
63
80
103
125
154
182
217
239
274
314
365
405
439
473
524

23
31
40
50
66
86
111
137
165
205
245
268
308
342
393
439
485
524
581

18
24
31
39
51
66
87
105
131
160
194
217
239
274
314
348
393
416
462

24
32
42
54
72
94
126
150
186
234
276
318
366
420
492
558
636
690
786

THREE,THREE AND A HALF AND FOUR CORE, 650/1100V


ARMOURED OR UNARMOURED HR PVC CABLES
Laid Direct in the
Ground

Aluminum

Nominal
Area of
Conductor

Copper

Aluminum

Copper

Aluminum

Copper

Aluminum

Amps

Sqmm

Amps

Amps

Amps

Amps

Amps

Amps

19
25
32
42
56
71
94
119
150
180
222
252
288
330
390
438
504
546
624

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

24
31
41
51
68
88
113
137
165
200
239
274
308
342
393
439
485
536
587

18
24
32
40
52
68
87
105
125
154
188
211
239
268
314
348
382
422
462

19
27
34
43
57
73
92
113
143
171
200
222
257
291
336
382
410
462
507

16
21
26
34
44
57
72
88
108
131
160
177
200
228
268
296
331
365
399

20
29
36
47
62
79
108
132
162
198
240
276
318
366
426
480
546
648
752

16
22
28
36
48
61
84
103
126
156
186
216
246
288
336
378
450
510
576

In the Air

In Ducts

11 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

In the Air

In Ducts

www.sbeecables.in

PVC INSULATED POWER & CONTROL CABLES

IS : 1554 PART - 1 CURRENT RATINGS FOR

IS : 1554 PART - 1 -1988 CURRENT RATINGS FOR


TWIN CORE, 650/1100 V0LTS ARMOURED OR
UNARMOURED HR PVC CABLES

TABLE 21

CURRENT RATINGS
PVC & HRPVC INSULATED COPPER CONDUCTOR 1.1 KV GRADE CONTROL CABLE
CROSS SECTION 2.5 MM

CROSS SECTION 1.5MM


Number
of
Cores
2
3
4
5
6
7
8
9
10
12
14
16
19
21
24
27
30
33
37
44
52
61

With PVC Insulation


In ground
Amps

In Air
Amps

23
21
21
16
15
14
14
13
13
12
11
11
10
10
9
9
9
8
8
7
7
6

With HRPVC Insulation


In ground
Amps

20
17
17
14
13
13
12
12
11
10
10
9
9
8
8
8
7
7
7
6
6
6

With PVC Insulation

In Air
Amps

In ground
Amps

24
20
20
17
16
16
14
14
13
12
12
11
11
10
10
10
8
8
8
7
7
7

32
27
27
23
21
20
19
18
18
17
16
15
14
13
13
12
12
11
11
10
10
9

26
24
24
18
17
16
16
15
15
14
13
13
11
11
10
10
10
9
9
8
8
7

With HRPVC Insulation

In Air
Amps
27
24
24
19
18
17
16
15
15
14
14
13
12
11
11
10
10
9
9
9
8
8

In ground
Amps

In Air
Amps

36
31
31
26
24
23
22
21
21
19
18
17
16
15
15
14
14
13
13
11
11
10

32
29
29
23
22
20
19
18
18
17
17
16
14
13
13
12
12
11
11
11
10
10

PVC INSULATED POWER & CONTROL CABLES

BASIC ASSUMPTIONS:
Continuous current ratings given are based on the following Assumptions:
1) Max. Conductor Temperature for continuous operation
PVC
: 70C
HR PVC
: 85C
II) Thermal Resistivity Of Soi
: 150C cm/watt
III) Thermal Resistivity Of PVC
: 650C cm/watt
iv) Depth of Laying ( to the highest point of
the table laid direct in the ground or to the
top surface of the duct
: 75 Cm
v) Method of Installation :
A) Single Core Cables
: a) Two Cables in horizontal Touching.
: b)Three cables in trefoil touching formation
B) Multi core cables
- Installed Singly
vi) In case of control cables all cores are assumed to be carrying full load current.

TABLE 22

SHORT CIRCUIT RATINGS:


SHORT CIRCUIT RATING OF CONDUCTORS FOR
ONE SECOND DURATION (KILO AMPS)
Nominal
Area of
Conductor
Sq. mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000

PVC Cables
Copper
0.17
0.29
0.46
0.69
1.20
1.80
2.90
4.00
5.80
8.10
10.90
13.80
17.20
21.30
27.60
34.50
46.00
57.50
72.40
92.00
114.90

Aluminium
0.11
0.19
0.30
0.46
0.76
1.20
1.90
2.70
3.80
5.30
7.20
9.10
11.40
14.00
18.20
22.70
30.30
37.90
47.70
60.60
75.80

HR PVC Cables
Copper
0.16
0.26
0.42
0.63
1.00
1.70
2.60
3.70
5.20
7.30
9.90
12.50
15.60
19.30
25.00
31.30
41.70
52.10
65.60
83.30
104.20

Aluminium
0.10
0.17
0.28
0.41
0.69
1.10
1.70
2.40
3.50
4.80
6.60
8.30
10.40
12.80
16.60
20.70
27.60
34.50
43.50
55.20
69.00

1) Max. Conductor Temperature Prior to short circuit for normal PVC: 70C
for HRPVC :
85C
2) Max. Conductor Temperature at the termination of short circuit: 160C
Formula for calculating the short circuit rating for other duration
I =

I1
k I

where I1 = Short circuit rating for one second


= Short circuit rating for 'k' second
k = Duration in seconds
The above formula is valid for 'k' from 0.2 to 5 seconds

12 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

TABLE 23

24 TABLE

RATING FACTORS

IS - 1554 PART -1 - 1988


RATING FACTORS, FOR DEPTH OF LAYING (CABLES LAID
DIRECT IN THE GROUND)

IS - 1554 PART -1 - 1988


RATING FACTORS , FOR AIR AND GROUND TEMPERATURE

AMBIENT TEMP deg C


25.0
RATING FACTOR FOR PVC
1.25
RATING FACTOR FOR HRPVC 1.15

GROUND TEMP deg C


15
RATING FACTORS
1.17
RATING FACTOR FOR HRPVC 1.12

TABLE 25

30.0
1.16
1.11

20
1.12
1.08

35.0
1.09
1.05

25.0
1.06
1.04

40.0
1.00
1.00

30.0
1.00
1.00

45.0
0.90
0.94

35.0
0.94
0.95

SIZE
Upto & Including 1.1 kv

Depth of
Laying

50.0
0.81
0.88

Upto 25 Sq.mm
cm
75
90
105
120
150
180 or more

40.0
0.87
0.90

1.00
0.99
0.98
0.97
0.96
0.95

Above 25 Sq.mm
Upto 300 Sq.mm
1.00
0.98
0.97
0.96
0.94
0.93

Above 300 Sq.mm


1.00
0.97
0.96
0.95
0.92
0.91

IS - 1554 PART -1 - 1988


RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY
OF SOIL TWIN & MULTICORE CABLES LAID DIRECT IN THE GROUND

Nominal
Area of
Conductor

For value of thermal resistivity of soil in deg C cm/w

Sqmm

120

150

200

250

300

1.10
1.10
1.10
1.10
1.10
1.12
1.14
1.15
1.15
1.15
1.15
1.17
1.17
1.18
1.18
1.18
1.19
1.19
1.19

1.05
1.05
1.05
1.05
1.06
1.06
1.08
1.08
1.08
1.08
1.08
1.09
1.09
1.09
1.09
1.09
1.10
1.10
1.10

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.92
0.92
0.92
0.92
0.92
0.91
0.91
0.91
0.91
0.90
0.90
0.90
0.90
0.89
0.89
0.89
0.89
0.89
0.89

0.86
0.86
0.86
0.86
0.85
0.84
0.84
0.84
0.84
0.83
0.83
0.82
0.82
0.81
0.81
0.81
0.81
0.81
0.81

0.81
0.81
0.81
0.81
0.80
0.79
0.78
0.77
0.77
0.76
0.76
0.76
0.76
0.75
0.75
0.75
0.75
0.75
0.75

TABLE 26
IS - 1554 PART -1 - 1988 RATING FACTORS FOR VARIATIONS IN THERMAL RESISTIVITY OF SOIL
(TWO & THREE SINGLE CORE CABLES LAID DIRECT IN GROUND)
Nominal
Area of
Conductor

Sqmm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

TWO CABLES TOUCHING, FOR VALUES OF


THERMAL RESISTIVITY OF SOIL IN degC cm/w

THREE CABLES TREFOIL TOUCHING, FOR VALUES


THERMAL RESISTIVITY OF SOIL IN degC cm/w

100

120

150

200

250

300

100

120

150

200

250

1.15
1.15
1.15
1.15
1.15
1.17
1.18
1.18
1.18
1.19
1.19
1.21
1.21
1.21
1.21
1.21
1.21
1.21
1.22

1.08
1.08
1.08
1.08
1.08
1.09
1.09
1.09
1.09
1.09
1.09
1.10
1.10
1.10
1.10
1.10
1.10
1.10
1.10

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.91
0.91
0.91
0.91
0.90
0.90
0.90
0.90
0.90
0.89
0.89
0.89
0.89
0.89
0.89
0.89
0.88
0.88
0.88

0.84
0.84
0.84
0.84
0.83
0.83
0.82
0.82
0.82
0.81
0.81
0.80
0.80
0.80
0.80
0.80
0.80
0.80
0.80

0.78
0.78
0.78
0.78
0.77
0.77
0.76
0.75
0.75
0.74
0.74
0.74
0.74
0.74
0.74
0.74
0.74
0.74
0.74

1.18
1.18
1.18
1.18
1.18
1.19
1.19
1.20
1.20
1.21
1.22
1.22
1.22
1.22
1.22
1.22
1.24
1.24
1.24

1.09
1.09
1.09
1.09
1.09
1.09
1.09
1.09
1.09
1.10
1.10
1.10
1.10
1.10
1.10
1.10
1.11
1.11
1.11

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.9
0.9
0.9
0.9
0.89
0.89
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88

0.82
0.82
0.82
0.82
0.81
0.81
0.80
0.80
0.80
0.80
0.80
0.79
0.79
0.79
0.79
0.79
0.79
0.79
0.79

13 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

0.76
0.76
0.76
0.76
0.74
0.74
0.74
0.74
0.74
0.74
0.74
0.74
0.73
0.73
0.73
0.72
0.72
0.72
0.72

PVC INSULATED POWER & CONTROL CABLES

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

100

TABLE 27

IS : 1554 PART - 1 -1988


GROUP RATING FACTORS
A) FOR SINGLECORE CABLE LAID IN TREFOIL FORMATION
SPACING BETWEEN TREFOILS

NO OF TREFOIL IN
GROUPS

TOUCHING

15 cms

30 cms

45 cms

0.78

0.81

0.85

0.88

0.68

0.71

0.77

0.81

0.61

0.65

0.72

0.76

0.56

0.61

0.68

0.73

IS : 1554 PART - 1 -1988


GROUP RATING FACTORS FOR MULTICORE CABLES
A) Cables Laid Inside concrete trench with removable covers, on cable trays where air
circulation is retricted. the cables spaced by one cable diameter and tray in tiers by 300
mm. The Clearance of The Cable from the wall Is 25 mm.
No. of Cable
Traces In Tier

No. of Cable

0.90
0.85

3
0.88

6
0.85

0.95
0.90

0.83

0.81

9
0.84
0.80

3
6

0.88
0.86

0.83
0.81

0.81
0.79

0.79
0.77

0.78
0.76

B) Cable Laid on cable tray exposed to air, thecable spaced by one cable diameter and
Trays in tier by 300 mm. The clearance between the wall and the cable is 25mm.

B) CABLES LAID IN TREFOIL DUCT IN HORIZONTAL FORMATION


SPACING BETWEEN TREFOILS

NO OF TREFOIL IN
GROUPS

28 TABLE

GROUP RATING FACTORS

TOUCHING

45 cms

60cms

0.87

0.90

0.91

0.79

0.83

0.86

0.74

0.79

0.82

0.71

0.76

0.8

No. of Cable
Traces In Tier
1
2
3
6

No. of Cable
1
1.00
1.00
1.00
1.00

2
0.98
0.95
0.94
0.93

3
0.96
0.93
0.92
0.90

6
0.93
0.90
0.89
0.87

9
0.92
0.89
0.88
0.86

C) Cables Laid on cable cable trays expoed to air, the cables touching and trays In tiers by
300 mm. The clearance between the wall and the cable 25 mm.
C) cables laid in racks / trays in covered trench with removable covers where air circulation
is restricted, trefoils are seperated by two cable dia horizontally and the trays are In tiers
with 30 cm. Gap between them.
NO OF TREFOIL IN
HORIZONTAL FORMATION

NO OF RACK / TRAYS
IN TIERS

PVC INSULATED POWER & CONTROL CABLES

0.95

0.90

0.88
0.83

0.90

0.85

0.88

0.83

0.81

0.86

0.81

0.79

D) CABLES LAID AS IN 'C' BUT IN OPEN AIR


1

1.00

0.98

0.96

1.00

0.95

0.93

1.00

0.94

0.92

1.00

0.93

0.90

No. of
Trays

No. of Cable Per Tray

1
2

1
1.00
1.00

2
0.84
0.80

3
0.80
0.76

6
0.75
0.71

9
0.73
0.69

3
6

1.00
1.00

0.78
0.76

0.74
0.72

0.70
0.68

0.68
0.66

D) Cables laid direct in Ground in Horizontal Formation


No. of Trefoil
in Groups

TOUCHING

2
3
4
5
6

0.79
0.69
0.62
0.58
0.54

SPACE BETWEEN TREFOILS


15 cms
30 cms
0.82
0.75
0.69
0.65
0.61

0.87
0.79
0.74
0.72
0.69

45 cms
0.90
0.83
0.79
0.76
0.75

E) CABLES LAID IN SINGLE WAY DUCT/PIPES IN HORIZONTAL


No. of Trefoil
in Groups

TOUCHING

2
3
4
5
6

0.88
0.82
0.77
0.74
0.71

SPACE BETWEEN TREFOILS


30 cms
45 cms
0.90
0.84
0.80
0.78
0.76

0.92
0.87
0.84
0.82
0.81

60 cms
0.94
0.89
0.87
0.85
0.84

GUIDE LINES FOR LAYING OF SBEE CABLES


1)

2)

Recommended minimum bending radius of 1.1kv Grade Cable for Fixed Installation.
Single Core - 15 D
Multi Core 12 D
Where D is overall Diameter of cable.
Maximum Permissible Tensile strength for cable
a) For Cables pulled with Stocking
ARMOURED CABLES
P = 9 D
UNARMOURED CABLES
P = 5 D
Where P = pulling force in Newtons
D = outer Diameter of cable.
b) For Cables pulled by pulling eye: - If the cables are pulled by gripping the conductor directly with pulling eye, the Maximum permissible Tensile stress depends
on the Material of the Conductor and their cross section as given below: For Aluminium Conductors
= 30 N /mm
For Copper Conductors
= 50 N /mm

14 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174

www.sbeecables.in

HANDLING AND STORAGE OF CABLE DRUMS


a)

The cable drums or coils must not be dropped or thrown from railway wagons or trucks during unloading operation. A RAMP or Crane may be used for unloading cable
drums. If neither of them is available, a temporary ramps with inclination 1: 3 to 1: 4 approximately should be constructed,the cable drum should then be rolled over the
ramp by means of ropes and winches.Additionallya sand bed at the root of the ramp may be made to break the rolling back of cable drums.

b)

The arrows painted on the flange of the drum indicate the direction in which the drum should be rolled. The cable will unwind and become loose if the drum is rolled in the
opposite direction.

c)

The site chosen for storage of cable drums should be well drained and should preferably have a concrete surface / firm surface which will not cause the drums to sink and
thus lead to flange rot and extremely difficult in moving the drums & inturn avoiding damage to the cable.

d)

All drums should be stored in such a manner as to leave sufficient space between them for air circulation. It is desirable for the drums to stand on battens placed
directelyunder the flanges. During storage the drum should be rolled to an angle of 90 once every three months.

e)

In no case should the drums be stored on the flat i.e., with flange horizontally placed.

f)

Overhead covering is not essential unless the storage is for a long period. The cable should however, be protected from direct rays of the sun by leaving the outer battens
on or by providing some form of Sun shielding.

g)

Do not rewind cable to another drum. Whose barrel diameter is less than the existing drum diameter.

NOTE: All data given in this catalogue is approximate and are subject to manufacturing tolerance
Delivery length tolerance 5% length more than normal as per customer request.
All figures given in various tables are indicative only.

LAB @ SBEE

15 l PRODUCT CATALOGUE l PVC IS1554 (PT1):1988 CM/L 6358174