Sei sulla pagina 1di 18

CONTROL BUILDING - SHEAR WALL ALONG GRID Aa

TEMPERATURE REINFORCEMENT CALCULATIONS


WALL
L

Size of the wall(m)

11.8

Thickness of the pour(H')

1.9

Volume of concrete(V)

17.94 m3

Exposed surface area(A)

57.32 m2

Volume/EX. Sur. Area(V/A)

0.313 m

Effective V/S

1.03 feet

1.75 feet

Design temp difference(TE)

=
103.0 oF
(Fig-2) of Report on Concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16
Cement content

H
0.8

1.9

(from charts)

360 Kg/m3

CALCULATION OF DESIGN TEMP DIFFERENCE


Placement temp assumed

29 oC

Elastic modulus of rock(Ef)

4990000 psi

Grade of concrete

Elastic modulus of concrete(Ec)

25
28500 Mpa

=
multiplier(m)

4132500 psi
1/(1+(AgEc/AfEf)

0.751

L/H

6.21 >2.5

Effective degree of restraint(Ke)

mKR

KR

((L/H-2)/(L/H+1))h/H

Height of the pour from bottom(h)

1.9

KR

0.32

KRE

0.241

for L/H>=2.5

Allowable temp difference

28.41/KRE

117.67 oF

PHYSICAL PROPERTIES OF CONCRETE


Tensile strength(f's)

6 x sqrt(fc)

323.11 psi

Co-eff of thermal expansion

0.00000528 /oF

Crack-width factor

0.004

clear cover

50

Allowable crack width(w)

0.2 mm

0.0079 inches

CALCULATION OF REINFORCEMENT
Dia of bar used

36 mm

Effective cover(dc)

68 mm

2.68 inches

spacing of bars

Spacing of bars

5.512 inches

Effective conc area around


each bar(A)

29.51 sq, inches

for limiting value of crack width of


stress in reinforcement
fs

140.00 mm

0.0079 in

=
=

w x 106/(0.076 x (dcA)1/3)

(psi)

24144.85 psi
w/18(KRECTTE-f't/Ec)

Average crack spacing(L')

f't/Ec

0.00015 (for Seasonal Cracking)

-23.403 ft

L'/2H'

-1.877

B(Width of RC element)

Reqd area of steel(Ab)

12 inches
0.2f't/fs(1-L'/2H')(BH')/(NB(H'-dc)H')

H' is thickness of pour

NB

=
=

Temp Renf as per calculations

=
=

No of bars in width B
2.177
3.2920 sq.in per given spacing of 5.512 inches
75.93 cm2/m

Min renf
=
9.11 cm2/m
(cl.6.4.4 of Report on concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16 SH 19 OF 22)
(if depth<48 in, 0.12% of gross c/s area of section; if depth>48 in, (f't/fs) A or A/100)
flexure renf from output

1.66%

TEMPERATURE REINFORCEMENT CALCULATIONS


FOOTING NO
L

Size of the footing/raft(m)

32.1

Thickness of the pour(H')

1.325

Volume of concrete(V)

m3

Exposed surface area(A)

m2

Volume/EX. Sur. Area(V/A)

Effective V/S

15.7

1.325 m

4.35 feet

7.40 feet

Design temp difference(TE)

=
110.0 oF
(Fig-2) of Report on Concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16
Cement content

H
2.25

(from charts)

360 Kg/m3

CALCULATION OF DESIGN TEMP DIFFERENCE


Placement temp assumed

23 oC

Elastic modulus of rock(Ef)

4990000 psi

Grade of concrete

Elastic modulus of concrete(Ec)

25
28500 Mpa

=
multiplier(m)

4132500 psi
1/(1+(AgEc/AfEf)

0.751

L/H

14.27 >2.5

Effective degree of restraint(Ke)

mKR

KR

((L/H-2)/(L/H+1))h/H

Height of the pour from bottom(h)

2.25

KR

0.80

for L/H>=2.5

KRE

Allowable temp difference

0.604
28.41/KRE

47.07 oF

PHYSICAL PROPERTIES OF CONCRETE


Tensile strength(f's)

6 x sqrt(fc)

323.11 psi

Co-eff of thermal expansion

0.00000528 /oF

Crack-width factor

0.004

clear cover

75

Allowable crack width(w)

0.3 mm

0.0118 inches

CALCULATION OF REINFORCEMENT
Dia of bar used

36 mm

Effective cover(dc)

93 mm

3.66 inches

spacing of bars

Spacing of bars

8.858 inches

Effective conc area around


each bar(A)

64.87 sq, inches

for limiting value of crack width of


stress in reinforcement
fs

0.0118 in

=
=

Average crack spacing(L')

f't/Ec

L'/2H'

225.00 mm

w x 106/(0.076 x (dcA)1/3)

(psi)

25094.67 psi
w/18(KRECTTE-f't/Ec)
0.00015 (for Seasonal Cracking)

3.272 ft

0.376

B(Width of RC element)

12 inches

Reqd area of steel(Ab)

0.2f't/fs(1-L'/2H')(BH')/(NB(H'-dc)H')

No of bars in width B

H' is thickness of pour

NB

=
Temp Renf as per calculations

=
=

1.355
0.7980 sq.in per given spacing of 8.858 inches
22.90 cm2/m

Min renf
=
23.97 cm2/m
(cl.6.4.4 of Report on concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16 SH 19 OF 22)
(if depth<48 in, 0.12% of gross c/s area of section; if depth>48 in, (f't/fs) A or A/100)
flexure renf from output

32.17 cm2/m

Total renf reqd

56.14 cm2/m

TEMPERATURE REINFORCEMENT CALCULATIONS


FOOTING NO
L

Size of the footing/raft(m)

32.1

Thickness of the pour(H')

1.325

Volume of concrete(V)

m3

Exposed surface area(A)

m2

Volume/EX. Sur. Area(V/A)

Effective V/S

15.7

1.325 m

4.35 feet

7.40 feet

Design temp difference(TE)

=
97.0 oF
(Fig-2) of Report on Concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16
Cement content

H
2.25

(from charts)

360 Kg/m3

CALCULATION OF DESIGN TEMP DIFFERENCE


Placement temp assumed

19 oC

Elastic modulus of rock(Ef)

4990000 psi

Grade of concrete

Elastic modulus of concrete(Ec)

25
28500 Mpa

=
multiplier(m)

4132500 psi
1/(1+(AgEc/AfEf)

0.751

L/H

14.27 >2.5

Effective degree of restraint(Ke)

mKR

KR

((L/H-2)/(L/H+1))h/H

Height of the pour from bottom(h)

2.25

KR

0.80

for L/H>=2.5

KRE

Allowable temp difference

0.604
28.41/KRE

47.07 oF

PHYSICAL PROPERTIES OF CONCRETE


Tensile strength(f's)

6 x sqrt(fc)

323.11 psi

Co-eff of thermal expansion

0.00000528 /oF

Crack-width factor

0.004

clear cover

75

Allowable crack width(w)

0.3 mm

0.0118 inches

CALCULATION OF REINFORCEMENT
Dia of bar used

36 mm

Effective cover(dc)

93 mm

3.66 inches

spacing of bars

Spacing of bars

8.858 inches

Effective conc area around


each bar(A)

64.87 sq, inches

for limiting value of crack width of


stress in reinforcement
fs

0.0118 in

=
=

Average crack spacing(L')

f't/Ec

L'/2H'

225.00 mm

w x 106/(0.076 x (dcA)1/3)

(psi)

25094.67 psi
w/18(KRECTTE-f't/Ec)
0.00015 (for Seasonal Cracking)

4.124 ft

0.474

B(Width of RC element)

12 inches

Reqd area of steel(Ab)

0.2f't/fs(1-L'/2H')(BH')/(NB(H'-dc)H')

No of bars in width B

H' is thickness of pour

NB

=
Temp Renf as per calculations

=
=

1.355
0.6726 sq.in per given spacing of 8.858 inches
19.31 cm2/m

Min renf
=
23.97 cm2/m
(cl.6.4.4 of Report on concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16 SH 19 OF 22)
(if depth<48 in, 0.12% of gross c/s area of section; if depth>48 in, (f't/fs) A or A/100)
flexure renf from output

32.17 cm2/m

Total renf reqd

56.14 cm2/m

TEMPERATURE REINFORCEMENT CALCULATIONS


FOOTING NO
L

Size of the footing/raft(m)

32.1

Thickness of the pour(H')

1.325

Volume of concrete(V)

m3

Exposed surface area(A)

m2

Volume/EX. Sur. Area(V/A)

Effective V/S

15.7

1.325 m

4.35 feet

7.40 feet

Design temp difference(TE)

=
133.0 oF
(Fig-2) of Report on Concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16
Cement content

H
2.25

(from charts)

360 Kg/m3

CALCULATION OF DESIGN TEMP DIFFERENCE


Placement temp assumed

29 oC

Elastic modulus of rock(Ef)

4990000 psi

Grade of concrete

Elastic modulus of concrete(Ec)

25
28500 Mpa

=
multiplier(m)

4132500 psi
1/(1+(AgEc/AfEf)

0.751

L/H

14.27 >2.5

Effective degree of restraint(Ke)

mKR

KR

((L/H-2)/(L/H+1))h/H

Height of the pour from bottom(h)

2.25

KR

0.80

for L/H>=2.5

KRE

Allowable temp difference

0.604
28.41/KRE

47.07 oF

PHYSICAL PROPERTIES OF CONCRETE


Tensile strength(f's)

6 x sqrt(fc)

323.11 psi

Co-eff of thermal expansion

0.00000528 /oF

Crack-width factor

0.005

clear cover

75

Allowable crack width(w)

=
=

0.375 mm
0.0148 inches

CALCULATION OF REINFORCEMENT
Dia of bar used

36 mm

Effective cover(dc)

93 mm

3.66 inches

spacing of bars

Spacing of bars

8.858 inches

Effective conc area around


each bar(A)

64.87 sq, inches

for limiting value of crack width of


stress in reinforcement
fs

0.0148 in

=
=

Average crack spacing(L')

f't/Ec

L'/2H'

225.00 mm

w x 106/(0.076 x (dcA)1/3)

(psi)

31368.34 psi
w/18(KRECTTE-f't/Ec)
0.00015 (for Seasonal Cracking)

2.995 ft

0.345

B(Width of RC element)

12 inches

Reqd area of steel(Ab)

0.2f't/fs(1-L'/2H')(BH')/(NB(H'-dc)H')

No of bars in width B

H' is thickness of pour

NB

=
Temp Renf as per calculations

=
=

1.355
0.6710 sq.in per given spacing of 8.858 inches
19.26 cm2/m

Min renf
=
19.18 cm2/m
(cl.6.4.4 of Report on concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16 SH 19 OF 22)
(if depth<48 in, 0.12% of gross c/s area of section; if depth>48 in, (f't/fs) A or A/100)
flexure renf from output

32.17 cm2/m

Total renf reqd

51.43 cm2/m

TEMPERATURE REINFORCEMENT CALCULATIONS


FOOTING NO
L

Size of the footing/raft(m)

32.1

Thickness of the pour(H')

1.325

Volume of concrete(V)

m3

Exposed surface area(A)

m2

Volume/EX. Sur. Area(V/A)

Effective V/S

15.7

1.325 m

4.35 feet

7.40 feet

Design temp difference(TE)

=
110.0 oF
(Fig-2) of Report on Concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16
Cement content

H
2.25

(from charts)

360 Kg/m3

CALCULATION OF DESIGN TEMP DIFFERENCE


Placement temp assumed

23 oC

Elastic modulus of rock(Ef)

4990000 psi

Grade of concrete

Elastic modulus of concrete(Ec)

25
28500 Mpa

=
multiplier(m)

4132500 psi
1/(1+(AgEc/AfEf)

0.751

L/H

14.27 >2.5

Effective degree of restraint(Ke)

mKR

KR

((L/H-2)/(L/H+1))h/H

Height of the pour from bottom(h)

2.25

KR

0.80

for L/H>=2.5

KRE

Allowable temp difference

0.604
28.41/KRE

47.07 oF

PHYSICAL PROPERTIES OF CONCRETE


Tensile strength(f's)

6 x sqrt(fc)

323.11 psi

Co-eff of thermal expansion

0.00000528 /oF

Crack-width factor

0.005

clear cover

75

Allowable crack width(w)

=
=

0.375 mm
0.0148 inches

CALCULATION OF REINFORCEMENT
Dia of bar used

36 mm

Effective cover(dc)

93 mm

3.66 inches

spacing of bars

Spacing of bars

8.858 inches

Effective conc area around


each bar(A)

64.87 sq, inches

for limiting value of crack width of


stress in reinforcement
fs

0.0148 in

=
=

Average crack spacing(L')

f't/Ec

L'/2H'

225.00 mm

w x 106/(0.076 x (dcA)1/3)

(psi)

31368.34 psi
w/18(KRECTTE-f't/Ec)
0.00015 (for Seasonal Cracking)

4.090 ft

0.470

B(Width of RC element)

12 inches

Reqd area of steel(Ab)

0.2f't/fs(1-L'/2H')(BH')/(NB(H'-dc)H')

No of bars in width B

H' is thickness of pour

NB

=
Temp Renf as per calculations

=
=

1.355
0.5421 sq.in per given spacing of 8.858 inches
15.56 cm2/m

Min renf
=
19.18 cm2/m
(cl.6.4.4 of Report on concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16 SH 19 OF 22)
(if depth<48 in, 0.12% of gross c/s area of section; if depth>48 in, (f't/fs) A or A/100)
flexure renf from output

32.17 cm2/m

Total renf reqd

51.35 cm2/m

TEMPERATURE REINFORCEMENT CALCULATIONS


FOOTING NO
L

Size of the footing/raft(m)

32.1

Thickness of the pour(H')

1.325

Volume of concrete(V)

m3

Exposed surface area(A)

m2

Volume/EX. Sur. Area(V/A)

Effective V/S

15.7

1.325 m

4.35 feet

7.40 feet

Design temp difference(TE)

=
97.0 oF
(Fig-2) of Report on Concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16
Cement content

H
2.25

(from charts)

360 Kg/m3

CALCULATION OF DESIGN TEMP DIFFERENCE


Placement temp assumed

19 oC

Elastic modulus of rock(Ef)

4990000 psi

Grade of concrete

Elastic modulus of concrete(Ec)

25
28500 Mpa

=
multiplier(m)

4132500 psi
1/(1+(AgEc/AfEf)

0.751

L/H

14.27 >2.5

Effective degree of restraint(Ke)

mKR

KR

((L/H-2)/(L/H+1))h/H

Height of the pour from bottom(h)

2.25

KR

0.80

for L/H>=2.5

KRE

Allowable temp difference

0.604
28.41/KRE

47.07 oF

PHYSICAL PROPERTIES OF CONCRETE


Tensile strength(f's)

6 x sqrt(fc)

323.11 psi

Co-eff of thermal expansion

0.00000528 /oF

Crack-width factor

0.005

clear cover

75

Allowable crack width(w)

=
=

0.375 mm
0.0148 inches

CALCULATION OF REINFORCEMENT
Dia of bar used

36 mm

Effective cover(dc)

93 mm

3.66 inches

spacing of bars

Spacing of bars

8.858 inches

Effective conc area around


each bar(A)

64.87 sq, inches

for limiting value of crack width of


stress in reinforcement
fs

0.0148 in

=
=

Average crack spacing(L')

f't/Ec

L'/2H'

225.00 mm

w x 106/(0.076 x (dcA)1/3)

(psi)

31368.34 psi
w/18(KRECTTE-f't/Ec)
0.00015 (for Seasonal Cracking)

5.155 ft

0.593

B(Width of RC element)

12 inches

Reqd area of steel(Ab)

0.2f't/fs(1-L'/2H')(BH')/(NB(H'-dc)H')

No of bars in width B

H' is thickness of pour

NB

=
Temp Renf as per calculations

=
=

1.355
0.4167 sq.in per given spacing of 8.858 inches
11.96 cm2/m

Min renf
=
19.18 cm2/m
(cl.6.4.4 of Report on concrete placement temperature and pour thickness
TAPP-3&4/TCE-2191/DR/CV/24000/16 SH 19 OF 22)
(if depth<48 in, 0.12% of gross c/s area of section; if depth>48 in, (f't/fs) A or A/100)
flexure renf from output

32.17 cm2/m

Total renf reqd

51.35 cm2/m

Potrebbero piacerti anche