Sei sulla pagina 1di 20

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

8 in 1 full function HD Encoder Users Manual

8 in 1 full function HD Encoder

8 in 1 full function HD Encoder


User Manual

Version

1.1
2013.08.06

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Chapter 1 Product introduction


1

.1

Overview
8 in 1 full-function professional HD Audio Video Encoder newly developed by Hongtushixun with
multiplexer function. It comes with 8 HDMI Video or 8HD-SDI inputs(optional); Video supports
MPEG-2 and H.264 Encoding format with higher encoding compression efficiency and excellent
video quality; Audio supports MPEG-1 Audio Layer2LC-AAC, HE-AAC encoding format. In
additional to the encoding function to 8 HDMI Audio Video signals, at the same time 1ASI input
and 1IP input(optional, IP output is included) are available to MPTS output together with existed
TS stream from encoding after they are multiplexed. It comes with 1group ASI multiplexing
output(2 routes) and 1IP output port(optional, IP input is including), IP output supports 16 routes
SPTS or 1MPTS output. IP and ASI stream output(consistent or inconsistent) is independent.
You can choose H.264 encoding or MPEG-2 encoding for different input. In the H.264 encoding
mode, each input can simultaneously output two streams with different resolution for different
network requirements.
Its higher integration and versatile design can effectively reduce cost of digital TV system. It can
be widely used in different digital TV head-end system, Digital Terrestrial and IPTV digital TV
systems.

.2

Functions
Support MPEG-2 and H.264 Video Encoding
Support MPEG-1 Layer 2,LC-AAC or HE-AAC Audio Encoding
Support PALNTSC video format
Support supper lower bit rate encoding
Support edit and insert PSI/SI
Support VBR and CBR video encoding mode
IP and ASI stream output(consistent or inconsistent) is independent
Support IP output with 1MPTS or 16 SPTS
In the H.264 encoding mode, each input can simultaneously output two streams with different
resolution for different network requirements.
Support real time monitoring output bit rate.
Support Web Management
High reliability design, stable operation, high performance and low cost
1U Standard case unit

.3

Technical indicators
8 HDMI inputs8 HD-SDI inputs(BNC interface)
Input

Optional

1 ASI input(BNC interface)


1 IP input(RJ45 port)

Optionalincluding IP
output

8 IN 1 FULL FUNCTION HD ENCODER


Video Encoding
Format

H.264/AVC High Profile compliant


H.264/AVC Main Profile compliant
H.264/AVC Baseline Profile compliant
MPEG-2 MP@ML compliant
*The video format is 4:2:0 with 8bits

Audio Encoding
Format

MPEG-1 Audio Layer 2


AAC-LC HE-AAC

Audio Sampling
Encoding rate
Video encoding
rate
Video encoding
mode

32 kHz 44.1kHz 48kHz

Audio encoding
rate

Your Best Choice!

H.264 0.8 -10Mbps MPEG-2 1.2 - 10Mbps


H.264:VBR

MPEG-2:CBRVBR

AAC
96/112/128/160/192/224/256/320/384Kbps
MPEG-1 Audio Layer 2:
192/224/256/320/384Kbps

PSI/SI Inset

PAT PMT SDT NIT

ASI input bit rate

108Mbps(BNC-J12(75 Ohm)interface)

IP input bit rate

860Mbps support 1 unicast multicast


Support 1 IP MPTS inputunicast multicast

Multiplexing
IP Packages
1-7
Function
IP Package format 188 204
MTU

Max 1500

Anti vibration Ability 300ms


ASI Output

Interface

1 group with 2 ASI input BNC-Female(75 Ohm)

Output bit rate

Package quantity

Support max 108M bit rate, Max 256PID for


each channel
Optional,Including
1 10/100/1000Base-T RJ-45
IP input
860Mbps support Unicast, Multicast and
filtering empty packages
Support 16 SPTS or 1MPTS output with max
256 PID
7

Package format

188

Interface

Rj45 10/100M

Management

WEB support online upgrading, parameter


guiding in or out.

Language

Chinese and English

Interface

Output bit rate


IP Output

Management
function

8 IN 1 FULL FUNCTION HD ENCODER


Apply
universally

.4

Your Best Choice!

Size(LxWxH)

483mm44mm500mm

Weight

4kg

Temperature

0~45(working), -20~80reserving

Power

AC 100V10% 60Hz 220V10%, 50Hz

Power
Consumption

25W

Appearance and Description


8 in 1 full function HD encoder Front Pannel

CH

ENCODER

1
12

ASI IN

POWER

IP IN

ALARM

Encoding 1-8 channels input interface lock Indicator light(green)

Encoding IP IN signal lock indicator light(green)

Encoding bit rate overflow indicator light(green)

Encoding ASI IN signal lock indicator light(green)

The power indicatorred

8 in 1 full function HD encoder Rear Panel

1
IP IN

ASI

15

14

13

12

HDMI 8

HDMI 7

HDMI 6

HDMI 5

HDMI 4

HDMI 3

HDMI 2

HDMI 1

11

10

AC110V-220V-50/60Hz

NMS

RST
IP OUT

ASI IN OUT

16 17 18 19

8 IN 1 FULL FUNCTION HD ENCODER


1

Reset button

ASI input interface

GE input/output interface

ASI output homologous


57 interface

Your Best Choice!

Network management port

16 Power switch

89101112131415 1-8 channels HDMI Video/Audio input interface


17 Fuse

18 Power Jack

19 Ground terminal

Chapter 2 Installation guide


2

.1

Acquisition Check
When user open the package of the device, it is necessary to check the packaging materials of
widgets, check items in the package according to packing list or the following items:
8 in 1 full function HD encoder
1
User Manual
1
AC input power plug wire
1
If any item is missing or mismatches with the list above, please contact the company
immediately.

.2

Installation Preparation
When user install the device, please follow the following steps,The details of installation will be
described at the rest part of this chapter, user can also refer to the rear panel chart, this chapter
mainly include the following content.
Checking the possible device missing or damage during the transportation.
Preparing relevant environment for installation.
Installing Encoder.
Connecting signal wires.
Connecting communication port(optional).
2.2.1 Devices Installation Flow Chart illustrated as follows

Acquisition
Check

Fixing
Device

Connecting
Grouding
Wire and
Power
Cord

Connecting
Signal Wire

Setting
Parameter

Running
Device

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

2.2.2 Environment Requirement


Requirement

Items

When the devices are installed in several rows in the device room,their
Installation space distance should be between 1.2~1.5m, and the distance to the wall should
be no less than 0.8m.
No conduction, and no dusting Mass resistivity of the antistatic flooring: 1X
Floor of the
107~1X1010, Grounding current limiting resistance: 1M. Floor bearing:
2
equipment room
more than 450Kg/m
Environment
Temperature
Relative
temperature
Pressure
Machine rooms
window & door
Machine rooms
wall
Fire prevention
Power supply

5~40(sustainable) 0~45(short term)The air conditioner is


recommended to install.
20%~80% sustainable 10%~90% short time
86~105KPa
They must be sealed with dust proof ruber strip. And the windows should
be installed with double glass and sealed strictly.
Wall paper can be pasted, and flat paint can be used, but powdered paint
isnt applicable.
Machine room should be equipped with fire alarm system and extinguisher.
It requires three sets of separate power supply system: device power, airconditioner power and lighting power, device power provided by AC power.

2.2.3 Grounding System design Requirements


Each function modules good grounding design will guarantee reliable and stable operation of the
device, also guarantee against lighting, anti-interference. Therefore, the system grounding must
follow this rule.
Outer conductor of coaxial cable and both ends of shielding layer should keep good electrical
contact with surface of the metal chassis of connected devices
Grounding conductor must use copper conductor to reduce the high frequency impedance,
grounding wire must be as thick and short as possible
Both ends of the ground wire connection point should confirm the electrical contact is good,
and should be done anti corrosive processing.
Prohibit using the other equipment as the part of the ground wires electrical connection.
Conductor cross-sectional area between Cabinet and grounding wire of lightning protection
2
should be equal or greater than 25mm .
2.2.4 Cabinet Grounding
Grounding terminal of each cabinet in same room should be separately connected to protected
copper platoon, the grounding wire should be as short as possible, if the wiring is too long when
the project installed, should be cut off to avoid grounding wire circling, conductor cross-sectional
2
area between Ground terminal and ground platoon should be equal or greater than 25mm
2.2.5 Device Grounding
Connect protective grounding terminal to protective grounding wire of assembly cabinet with wire.

8 IN 1 FULL FUNCTION HD ENCODER


2

.3

Your Best Choice!

The power wire connection


Power jack located in left side of the rear panel, next to the power socket, is the power switch,
under the left of the power socket is the connective screw of protective grounding wire.
Connect the power wire
Insert one end of the power wire into AC power socket, and another end connected to AC power.
Connect the grounding wire
When the device connects separately to protective ground, it should adopt independent
grounding way, that is, grounded together with other devices(such as transmission equipment),
Grounding resistance of Joint Ground is less than 1.
CautionBefore connecting the power wire, encoder power switch must be placed in OFF
position, and required grounded together with the power supply system.

.4

Input, output signal wire connection


Signal wire connection include connection of output and input signal wire, signal wire of input
HDMI high-definition connected with HDMI high-definition interface of encoder, the other end
connect with the output interface of the front-end source equipment. The encoder has 1GE
port(IP signal input/output network port), it can connected to the device of transmission network
with network wire.

.5

Connecting the encoder communications network management port


Encoder parameters are set by the network interface device operation. Therefore encoder device
must be connected via 100M Ethernet switch with the computer.

Chapter 3 Operation Guide


8 in1 full function HD encoder adopt embedded WEB Service, in computer multiple
browser(support IE browser, Firefox browser, google browser etc.)interface, set each parameter,
system maintenance and upgrade set, the default setting of device can be used before the
normal business, also can modify or reconfigured the device parameter settings.
3

.1

Enter the WEB interface of the device


After connected, turn on the power of the all device, select any browser on computer, such as IE
browser, Google, Firefox browser, enter in the browser address bar: //101.101.101.20/,(Note: the
default IP address is 20), click the search button to enter the following interface.

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure 1 WEB interface


3

.2

Enter the Home page interface of network management


In figure 1 interface, type admin in the user name bar box and type 12345 in the pass word
bar box, click on login button to enter the network equipment home interface, As shown in figure
2 below

Figure 2 Home Interface

8 IN 1 FULL FUNCTION HD ENCODER


3

.3

Your Best Choice!

Enter into device network management condition monitoring interface


In figure 2 interface,click on the top row of "Monitor" (condition monitoring) key to enter the device
network "condition monitoring" screen. Respectively display reads 1, "ASI Output Status" (ASI
output rate), 2, "ASI Input Status" (input rate), 3, "IP Output Status" (IP output rate), 4 "alarm
"(alarm), 5," Encoder Status "(coded channel condition monitoring, normal green LED is lit, not
normal green LED does not light) 5 group, the English state monitoring information, as shown in
figure 3 below

Figure 3 ASI output"condition monitoring" network management interface

Figure 4 English ASI input"Condition Monitoring" network management interface

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure 5 English IP output"condition monitoring" network management interface

Figure 6 English alarm"condition monitoring" network management interface

10

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure7 English encoding channel "condition monitoring" network management interface


3

.4

NMS device "Input Output Settings" interface to enter


In Figure 2 interface, click on the top row of "Input / Output" key to enter the device network
"input-output" setting interface. Click on the left top of the "Input / Output Settings" input,
output setting keys appear: "Input Settings", "Output Settings". Click on each "Input
Settings" button, "Output Settings" button. Enter respectively the "Encode Settings", "ASI
Output Settings" and "IP Output Settings" IP network interface output settings.
3.4.1"Input Settings"(encoding parameter settings):There are five content
1.Video Input Informationincluding video input Channel Video Input Resolutionvideo input
resolution TwoWhen encoding the input source is not inserted into the video, input information
will not be displayed
2.Primary Video Encode Settingincluding Encode FormatVideo GOPCBR/VBR
Dynamic Bite rate MaxVideo Average BitrateDynamic Biterate Min 6.
3.Audio Input Settings including Audio Sample Rate1.
4.Primary Audio Settings including Audio FormatsSound ModeAudio Bit Rate 3.
5.System Settings including Primary Stream enable 1. Enter Input Settingsencoding parameter
settingsChinese and English network interface as shown in Figure 8. The below figure is the
diagram of the encoding channel 1. 8 encoding channel encoding settings management
interfaces are the same needing set.

11

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure8 Input setting "encoding setting" network management interface


3.4.2 ASI Output Settings
EnterASI Output Settingsnetwork interface 1 Under Output Bitrate can be set
150Mbps output bitrate determined in accordance with specific needs 2 InEnable
according to the needs select ON there is stream output or select OFF there is no
stream output ASI Output Settings Chinese and English network management interface
as shown in Figure 9

Figure 9 English ASI output setting network management interface

12

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

3.4.3 IP Output Settings:Here are two content as below


1. General Settingsincludes 5 type of "Lcal IP"Lcal MAC Lcal Port Work
ModeOutput Type
2. Output Settingsincludes 4 type of Dest IP Dest Port Dest MAC

Enable.
IP Output Settings TS over IP module settingsnetwork management interface as
shown in Figre10.

Figure10 IP output settingTS over IP module settingsnetwork management interface


3

.5

Enter device network managementMux settingsinterface


In Figure 2 interface, click on the top row Mux Settings button to enter the device network
management Mux Settings interface. Click on the top left of Mux Settings button may
appear two main items Input Program Info Output Program Edit click on
each Input Program Infobutton Output Program Editbutton. Enter respectively
Encode Input Informations ASI Input Informations NIT Edit ASI Output Edit

IP Output Edit 5 small items network management interface.


3.5.1 Input Program Info under the main Encode Input Informations interface
ClickInput Program Infobutton will appearEncode Input InformationsASI Input
Informations 2 small items. ClickEncode Input Informations button to enter the encoding
channel Mux settings network management interface.

13

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Encoding channel Mux setting network management interface has two main functions: 1 set
whereabouts encoding channels program, select 002 multiplex to IP output channels, select OFF,
not to be multiplexed output. 2 display encoding channels detailed program information, such
as TS ID, original network ID PMT PID PCR PID elementary stream video PID
elementary stream video PID PAT\CAT\SDT version conditional access system(EMM)
program type and the program providers information. And this information can only be viewed.
Please go to the output program main item when need to modify the program.
There are eight encoding channels, each channel has the same Mux setting network
management interface,1 encoding channel Mux setting network management interface as shown
figure 11.

Figure 11 Encoding channel Mux setting network management interface


3.5.2 Input Program Info under the main item ASI Input Informationsinterface
Click on "Input Program Info" button, it will appear "Encode Input Information", "ASI
Input Information" 2 small items. Click on "ASI Input Information" button to enter the ASI input
channels Mux settings network interface.
ASI input channel Mux setting network interface has two main functions: 1detailed ASI input
channels information after searching all programs, such as TS ID, original network ID, PMT PID,
PCR PID, the elementary stream video PID, basic streaming audio PID, PAT / CAT / SDT
version, conditional Access System (EMM), program type, program providers information. The
provided information can only be viewed, when it needs to modify the program, please enter the
output program editing main item.
2After searching all the details on the program displayed in the search based on ASI input
channels , set the whereabouts ASI inputs of all programs, select 001 is multiplexed to ASI output
channel, select 002 is multiplexed to IP output channels, when you select OFF, is not to be
multiplexed output.
ASI input channels Mux setting network management interface as shown in Figure 12.

14

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure 12 ASI input channels Mux setting network management interface

3.5.3 "Output Program Edit" under the main item "NIT Edit" NIT editing interface
Click on "Output Program Edit" button. Enter Respectively "NIT Edit" "ASI Output Edit" ,
"IP Output Edit" 3 small items network management interface.
Click on "NIT Edit" button, you can enter the "Network information Edit" NIT table network
interface.
The NIT editor NMS interface has three main functions: 1 add directly, " Network ID, " Network
Name", " NIT version number" , NIT replace selection switch (ASI input stream NIT or self-edited
NIT) . 2 In the NIT description box may edit(currently only add DVB-C system, could be
upgraded later) TS ID, ON ID, frequency, modulation mode, symbol rate, FEC lnner, FEC outer7
items content, each NIT editor Upon completion, the hook inside the small box behind already
exist, such as the need NIT delete a message, click on the hook behind the small box inside it,
and click "Submit" to delete. 3, support program reuse and may choose to delete a set of
program (input program choices after reuse has box here, such as the need to remove the set of
programs, click the check, become effective after submission). 4, click the drop-down list on
each program can be edited detailed information of each program, here both ASI input channel
and coding input channels are the same.

15

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure 13 NIT table edit network management interface

3.5.4 Output Program Editthe main item ASI Output Editinterface


Click onOutput Program EditbuttonEnter respectively NIT EditASI Output Edit
IP Output Edit 3 small item network management interface
Click onASI Output Editbuttonyou can enterASI Output Editnetwork management
interface.
ASI output Edit network interface has four main functions:1 supports the display of TS ID,
original network ID, PAT, CAI, SDT version number and table interval(in milliseconds), TDT, TOT
meter interval(in milliseconds), the local conditional access system, multiplexing conditional
access system(EMM). 2Support selection users private description edit. 3Support program
multiplexing and can choose to remove one program(program input after selection multiplexing
tick here already, such as the need to remove this program, click on his hook, the entry into force
after submit). 4Click on the drop down list on each program details information can be edited,
Here both ASI input channel and encoding input channels are the same.
ASI output edit network management interface as shown in Figure 14

16

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

Figure 14 ASI output Edit network management interface


3.5.5 Output Program Edit the main item IP Output Edit interface
Click onOutput Program Editbutton, Enter respectively NIT EditASI Output Edit
IP Output Edit 3 small item network management interface.
Click onIP Output Edit buttonyou can enter IP Output Edit network management
interface.
IP Output Edit network management interface main function is the same with ASI output edit
network management interface. Refer to ASI output Edit network management interface main
function.
IP output edit network management interface as shown in Figure 15

Figure 15 IP output Edit network management interface


17

8 IN 1 FULL FUNCTION HD ENCODER


3

.6

Your Best Choice!

Device network managementdevice managementinterface to


In figure 2 interface, click on the top row Device management to enter the device
management button to appear four small item network management interface: System
SettingsDevice Restore Factory SettingsDevice Network Parameters EditUser
Management.Enter respectively to System Settings Device Restore Factory Settings

Device Network Parameters Edit User Management four small item network
management interface.
3.6.1 System Settingsinterface
Click on System Settingswill appear System Settingsnetwork management interface.
System setting network interface main functions as below:1 the date/time of acquisition and
submit .2parameter guide in/guide out. 3system upgrade.
System setting network management interface as shown in Figure 16.

Figure 16 System setting network management interface

18

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

3.6.2 Device Restore Factory Settings


Click on Device Restore Factory Settingswill appear Device Restore Factory Settings network
management interface.
Device Restore Factory Settingsnetwork management interface main function is to restore the
factory setting. When you find the device is not working in normal, if you do not know to configure
the device, please be careful with this option.
Device Restore Factory Settings network management interface as shown in Figure 17

Figure17 Device restore factory settings network management interface


3.6.3 Device Network Parameter Edit
Click onDevice Network Parameter Editit will appear Device Network Params Edit network
management interface.
Device Network Parameter Edit modify network management main function, display and
modify network IP address, gateway address, sub network mask, MAC address.
Device network parameters network management interface as shown in Figure 18

Figure17 Device restore factory settings network management interface


19

8 IN 1 FULL FUNCTION HD ENCODER

Your Best Choice!

3.6.4 User Management


Click on User Management,there will be User Management network management interface
User Management network management main function is to manage and modify user name
password .
User Management network management interface as shown in Figure 19.

The Musts of Safety


1.Please read this introduction carefully before use the equipment.
2.Note: when install the equipment, remember to correctly connect the protective grounding
cable first. After connect other signal cables, power off the equipment, then plug the outlet cable.
3.Note In order to ensure the equipment running stably, Do cut off the power before any
change of cable connection on the ports of back panel.
4.Make sure the working environment is under temperature 0-45C and other required
conditions. Keep the back panel ventilated. Make sure all the connections are correct of the
relative ports.
5.When initial use, make sure the A/V source is connected normally.
6.Do not open the lid to avoid electrical shock or damage of the unit.
7.Do not turn on and off the equipment too often, the time interval between on and off should be
at least 20 seconds.
8.If the equipment would not be in use for long time, please unplug the power cord. Do not use
damaged power in case of fire or electric shock.
9.Do not touch the power line with wet hands. When any liquid flows into the chassis, cut power
off IMMEDIATELY.
10.Put the equipment in a horizontal place. Do not stack heavy objects on the equipment to
prevent damage.
11.Settle the equipment in ventilated environment and suitable temperature. Keep the equipment
away from the fierce light, moisture and severe vibration.
12.If the working environment has sharp temperature difference as previous, please keep the
equipment off for one or two hours before power on again.
13.Between the machine power switch and power socket with fuse holder, When the machine
power overload or short circuit, the fuse tube disconnected, exchangeable with Specifications of
the new fuse tube. Remove the fuse tube block method: unplug the power plug with a
screwdriver inserted into the fuse holder gaps can skip the fuse tube block. New machine fuse
header contains two fuse tube, one of which is as a backup, damaged the fuse tube can be
removed, change another backup fuse tube, then the fuse tube to insert the original location.

20

Potrebbero piacerti anche