RenrocGroup(Pumps&Engineering)hasseveralpumpmodelscompliantwithAmericanPetroleum
InstituteAPI610.Ourcustomersintheoilrefiningandpetrochemicalindustrieshaveforyearsturnedto
ourproductsfortheirhighhead,lowflowservicesandotherdifficultorhazardousapplications.
API610specifiesrequirementsforcentrifugalpumps,includingpumpsrunninginreverseashydraulic
powerrecoveryturbines,foruseinpetroleum,petrochemical,andgasindustryprocessservices.This
InternationalStandardisapplicabletooverhungpumps,betweenbearingpumps,andvertically
suspendedpumps.Clause9providesrequirementsapplicabletospecifictypesofpumps.Allother
clausesofthisInternationalStandardapplytoallpumptypes.Illustrationsareprovidedofthevarious
specificpumptypesandthedesignationsassignedtoeachspecificpumptype.Itdoesnotcoversealless
pumps.

Overhung(OH)Pumps
Overhungpumpscomeinavarietyofconfigurationsandaremanufacturedtoanumberofinternational
standardsincludingAPI,ANSIandISO.Pumpsrangeinsizefromsmallindustrial25mmendsuction
designstolargebetweenbearingAPI610compliantmachines.

OH1
http://renrocgroup.com/pumpstandard/api610/

1/9

4/30/2015

API610|RenrocGroup

FootmountedsinglestageoverhungpumpsarereferredtoasOH1typepumps.(Thistypemeetsall
requirementsoftheInternationalStandardforANSIandISO).
MakeanEnquiry

OH2
CentrelinemountedsinglestageoverhungpumpsarereferredtoasOH2typepumps.Theyhavea
singlebearinghousingtoabsorballforcesimposeduponthepumpshaftandmaintainrotorposition
duringoperation.Thepumpsaremountedonabaseplateandareflexiblycoupledtotheirdrivers.
MakeanEnquiry

OH3
VerticalinlinesinglestageoverhungpumpswithseparatebearingbracketsarereferredtoasOH3type
pumps.Theyhaveabearinghousingintegralwiththepumptoabsorballpumploads.Thedriveris
mountedonasupportintegraltothepump.Thepumpsandtheirdriversareflexiblycoupled.
MakeanEnquiry

http://renrocgroup.com/pumpstandard/api610/

2/9

4/30/2015

API610|RenrocGroup

OH4
RigidlycoupledverticalinlinesinglestageoverhungpumpsshallbedesignatedpumptypeOH4.
Rigidlycoupledpumpshavetheirshaftrigidlycoupledtothedrivershaft.(Thistypedoesnotmeetall
therequirementsofInternationalStandard).
MakeanEnquiry

OH5
ClosecoupledverticalinlinesinglestageoverhungpumpsshallbedesignatedpumptypeOH5.Close
coupledpumpshavetheirimpellersmounteddirectlyonthedrivershaft.(Thistypedoesnotmeetallthe
requirementsofInternationalStandard).
MakeanEnquiry

BetweenBearing(BB)Pumps
TheBetweenBearingpumpsaredesignedforheavyduty,highpressureandhightemperature
applicationsinindustrialandHPIservices.Applicationsrangefromlighthydrocarbonsatlow
temperatures,tocorrosivefluids,cokerfurnacecharge,vacuumbottomsandotherservicesathigh
temperatures.

http://renrocgroup.com/pumpstandard/api610/

3/9

4/30/2015

API610|RenrocGroup

BB1
Axiallysplit1and2stagebetweenbearingspumpsshallbedesignatedpumptypeBB1.
MakeanEnquiry

BB2
Radiallysplit1and2stagebetweenbearingspumpsshallbedesignatedpumptypeBB2.
MakeanEnquiry

BB3
AxiallysplitmultistagebetweenbearingspumpsarereferredtoasBB3typepumps.
http://renrocgroup.com/pumpstandard/api610/

4/9

4/30/2015

API610|RenrocGroup

MakeanEnquiry

BB4
SinglecasingradiallysplitmultistagebetweenbearingspumpsarereferredtoasBB4typepumps.
Thesepumpsarealsocalledringsectionpumps,segmentalringpumpsortierodpumps.
Thesepumpshaveapotentialleakagepathbetweeneachsegment.(Thistypedoesnotmeetallthe
requirementsofthisInternationalStandard)
MakeanEnquiry

BB5
Doublecasingradiallysplitmultistagebetweenbearingspumps(barrelpumps)arereferredtoasBB5
typepumps.
MakeanEnquiry

VerticalSuspended(VS)Pumps
VerticalSuspendedpumpsareforapplicationsrangingfromwastewatersumpdutiestohighly
specializedoffshorefirefightingapplications
Designconfigurationsincludesidedischargeunitsusingendsuctionpumphydraulicsinaverticalsump
pump.VerticalcanpumpscanbedesignedtoenablethepumpstooperateinlowNPSHasituations.

http://renrocgroup.com/pumpstandard/api610/

5/9

4/30/2015

API610|RenrocGroup

VS1
Wetpit,verticallysuspended,singlecasingdiffuserpumpswithdischargethroughthecolumnare
referredtoaspumptypeVS1.
MakeanEnquiry

VS2
Wetpit,verticallysuspendedsinglecasingvolutepumpswithdischargethroughthecolumnarereferred
toaspumptypeVS2.
MakeanEnquiry

VS3
http://renrocgroup.com/pumpstandard/api610/

6/9

4/30/2015

API610|RenrocGroup

Wetpit,verticallysuspended,singlecasingaxialflowpumpswithdischargethroughthecolumnshall
arereferredtoaspumptypeVS3.
MakeanEnquiry

VS4
Verticallysuspended,singlecasingvolutelineshaftdrivensumppumpsarereferredtoasVS4type
pumps.
MakeanEnquiry

VS5
VerticallysuspendedcantileversumppumpsshallbedesignatedpumptypeVS5.
MakeanEnquiry

http://renrocgroup.com/pumpstandard/api610/

7/9

4/30/2015

API610|RenrocGroup

VS6
DoublecasingdiffuserverticallysuspendedpumpsarereferredtoasVS6typepumps.
MakeanEnquiry

VS7
DoublecasingvoluteverticallysuspendedpumpsarereferredtoaspumptypeVS7.
MakeanEnquiry

Manufacturers

http://renrocgroup.com/pumpstandard/api610/

8/9

4/30/2015

API610|RenrocGroup

loading

http://renrocgroup.com/pumpstandard/api610/

9/9

Potrebbero piacerti anche