Sei sulla pagina 1di 80

SECTION A

1850 Wilson Avenue, Toronto,


Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104

BALLASTS

ELECTRONIC BALLASTS
A1

ELECTRONIC BALLASTS

Electronic Ballasts
T5 Straight Lamps
T8 Straight Lamps
T12 Straight Lamps
T12 High Output Lamps
T5 Compact Fluorescent Lamps - CF Type
Long Twin Tube - 2G11 Type
Circline Lamps
2D Lamps
GU24 Adapter Ballasts
Dimmer Ballasts
Ballast Disconnect
Magnetic Ballasts
Emergency Ballasts
Appendix - Wiring Diagrams & Case Styles
Appendix: Electronic Ballasts: Standard Lead Lengths & Standard Packaging
Appendix and Suffix Guide

Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation.
While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,
no warranty is given in respect thereof and the company shall not be liable for any error herein.
Copyright 2011 Etlin-Daniels

A1
A2-A7
A8-A22
A23-A24
A25
A26-A32
A33-A37
A38
A39
A40
A41
A42-A43
A44-A55
A56-A64
A65-A73
A74-A79
A80

Electronic
Ballast

A2

T5 Straight Lamps
Lamp
Watts

4W

ElectronicBallasts

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

6W

8W

13W

14W

Lamp
Type

F4T5

F6T5

F8T5

F13T5

F14T5
HE

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-108-1-TP-FC

120

0.095

6.0

> 0.5

< 160

1.05

UL, cUL

28

V1

RS

EB-108-1-TP-FC-PH

120

0.095

6.0

> 0.5

< 160

1.05

UL, cUL

28

V1

PH

EB-108-1-TP-FC

120

0.12

8.0

> 0.5

< 160

1.0

UL, cUL

34

V1

RS

EB-108-1-TP-FC-PH

120

0.12

8.0

> 0.5

< 160

1.0

UL, cUL

34

V1

PH

EB-108-1-TP-FC

120

0.12

8.0

> 0.5

< 160

1.0

UL, cUL

28

V1

RS

EB-108-1-TP-FC-PH

120

0.12

8.0

> 0.5

< 160

1.0

UL, cUL

28

V1

PH

EB-114-1-TP-FC ws

120

0.23

14.0

> 0.5

< 150

1.0

UL, cUL

34

V1

RS

EB-114-1-TP-FC-PH

120

0.23

14.0

> 0.5

< 150

1.0

UL, cUL

24

V1

PH

EB-114-1-TP-FC ws

120

0.25

16.0

> 0.5

< 150

0.95

UL, cUL

34

V1

RS

EB-114-1-TP-FC-PH

120

0.25

16.0

> 0.5

< 150

0.95

UL, cUL

34

V1

PH

EB-108-1-TP-FC

120

0.13

8.5

> 0.5

< 130

1.0

UL, cUL

28

V1

RS

EB-108-1-TP-FC-PH

120

0.13

8.5

> 0.5

< 130

1.0

UL, cUL

28

V1

PH

EB-113-1-TP

C6

RS

EB-113-1-TP-MC

J1

RS

EB-113-1-TP-SL

N2

RS

EB-113-1-TP-SL-MC

P2

RS

EB-113-1-TP-SLL

N1

RS

EB-113-1-TP-SLL-MC

P1

RS

EB-113-1-TP-PN

S1

RS

EB-208-1-TP

C6

RS

EB-208-1-TP-MC

J1

RS

EB-208-1-TP-SL

N1

RS

EB-208-1-TP-SL-MC

P1

RS

EB-113-1-TP

C6

RS

EB-113-1-TP-MC

J1

RS

EB-113-1-TP-SL

N2

RS

EB-113-1-TP-SL-MC

P2

RS

EB-113-1-TP-SLL

N1

RS

EB-113-1-TP-SLL-MC

P1

RS

EB-113-1-TP-PN

S1

RS

EB-114-1-TP-FC

120

0.22

14

> 0.5

< 150

0.95

UL, cUL

28

V1

RS

EB-114-1-TP-FC-PH

120

0.22

14

> 0.5

< 150

0.95

UL, cUL

28

V1

PH

EB-213-1-TP ws

C6

RS

EB-213-1-TP-MC

J1

RS

EB-213-1-TP-SL

N1

RS

EB-213-1-TP-SL-MC

P1

RS

EB-114-1-TP-FC ws

120

0.23

15

> 0.5

< 150

0.95

UL, cUL

28

V1

RS

EB-114-1-TP-FC-PH

120

0.23

15

> 0.5

< 150

0.95

UL, cUL

28

V1

PH

EB-221PS-1-TP

120

0.44

30

> 0.5

< 130

0.95

UL, cUL

38

L7

PS

EB-228-1-TP-PH-SL

120

0.44

30

> 0.5

< 130

0.95

UL, cUL

38

N1

PH

120

120

120

120

0.17

0.28

0.25

0.43

10

17

15

28

> 0.5

> 0.5

> 0.5

> 0.5

< 150

< 150

< 150

< 150

1.1

0.95

0.95

0.95

UL, cUL

UL, cUL

UL, cUL

UL, cUL

28

30

28

30

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T5 Straight Lamps

14W

21W

Lamp
Type

F14T5

F21T5

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EPD-A14T5M

120~277 0.12-0.05

15

> 0.93

<10

UL, cUL

47

AA1

EPS-A14T5M

120~277 0.13-0.05

15

> 0.93

<10

UL, cUL

31

AA1

IS

ESD-A21T5S

120~277 0.15-0.07

18

> 0.97

<10/20

0.99

UL, cUL

48

AA2

PS

ESD-B21T5

277-347

0.07-0.06

19

> 0.99

<15/20

UL, cUL

48

AA2

PS

ESS-A21T5

120~277 0.15-0.05

18

> 0.99

<10

0.97

UL, cUL

48

AA1

PS

FSD-A18PBM ws

120~277 0.14-0.08

19

> 0.98

<10/15

1.02

UL, cUL

AA23

PS

GSD-A18PBM ws

120~277 0.14-0.08

19

> 0.98

<10/15

1.01

UL, cUL

AA24

PS

TSD-UV21T5M

120~277 0.15~0.07

18

> 0.98

<10/40

0.99

UL, cUL

AA1

PS

EPD-A14T5M

120~277 0.25~0.10

30

> 0.99

<10

0.93

UL, cUL

AA1

IS

EPT-A14T5M

120~277 0.25~0.11

30

> 0.99

<10

UL, cUL

50

AA1

IS

ESD-A21T5S

120~277 0.28-0.13

34

> 0.99

< 10/15

0.93

UL, cUL

49

AA2

PS

ESD-B21T5

277-347

0.13-0.10

35

> 0.99

< 10/15

UL, cUL

49

AA2

PS

TSD-UV21T5M

120~277 0.28-0.13

33

> 0.99

< 10/15

0.93

UL, cUL

AA1

PS

EPQ-A14T5M

120~277 0.36~0.16

44

> 0.99

<10

UL, cUL

51

AA1

IS

EPT-A14T5M

120~277 0.36~0.16

36

> 0.99

<10

0.93

UL, cUL

13

AA1

IS

EPT-A21T5M

120~277 0.36~0.16

43

> 0.99

<10

0.93

UL, cUL

51

AA1

IS

EPQ-A14T5M

120~277 0.47~0.20

56

> 0.99

<10

0.93

UL, cUL

14

AA1

IS

EPQ-A21T5M

120~277 0.45~0.20

54

> 0.99

<10

0.88

UL, cUL

14

AA1

IS

EPQ-A35T5M

120~277 0.45~0.20

55

> 0.99

<10

0.74

UL, cUL

14

AA1

IS

ESD-A21T5S

120~277 0.20~0.09

24

> 0.97

< 10/20

0.99

UL, cUL

48

AA2

PS

ESD-B21T5

277-347

0.09-0.08

26

> 0.97

< 10/20

0.99

UL, cUL

48

AA2

PS

ESS-A21T5

120~277 0.20~0.09

25

> 0.99

< 10/20

0.97

UL, cUL

48

AA2

PS

FSD-A18PBM

120~277 0.22~0.10

28

> 0.98

<10

0.93

UL, cUL

AA23

PS

GSD-A18PBM

120~277

0.22~0.1

28

> 0.98

<10

0.93

UL, cUL

A24

PS

TSD-UV21T5M

120~277 0.20~0.09

25

> 0.98

< 10/20

0.97

UL, cUL

AA1

PS

ESD-A21T5S

120~277 0.40-0.17

48

> 0.99

<10

0.91

UL, cUL

49

AA2

PS

ESD-B21T5

277~347 0.17-0.15

48

> 0.99

< 10/15

0.99

UL, cUL

49

AA2

PS

FSD-A32PBM ws

120~277 0.54~0.24

64

> 0.99

< 10/15

1.24

UL, cUL

33

AA23

PS

TSD-UV21T5M

120~277 0.40-0.17

48

> 0.99

<10

0.93

UL, cUL

AA1

PS

EPT-A21T5M

120~277 0.52~0.22

62

> 0.99

<10

0.90

UL, cUL

13

AA1

IS

EPQ-A21T5M

120~277 0.70~0.30

84

> 0.99

<10

0.89

UL, cUL

14

AA1

IS

EPQ-A35T5M

120~277 0.60~0.27

73

> 0.99

<10

0.70

UL, cUL

14

AA1

IS

EPQ-335T5S

79

> 0.97

<10

0.97

UL, cUL

14

AA3

IS

347

0.23

IS

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A3

Electronic
Ballast

ElectronicBallasts

A4

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T5 Straight Lamps

Lamp
Watts

Lamp
Type

21W F21T5 HE

21W

24W

F21T5
HE

F24T5
HO

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-114-1-TP-FC ws

120

0.30

21

28

V1

120

0.30

21

< 150
< 150

UL, cUL

EB-114-1-TP-FC-PH

> 0.5
> 0.5

0.80

0.80

UL, cUL

28

V1

RS
PH

EB-135HE-1-TP ws

120

0.34

22

> 0.5

< 150

1.0

UL, cUL

28

N1

RS

EB-135HE-1-TP-PH

120

0.34

22

> 0.5

< 150

1.0

UL, cUL

28

N1

PH

EB-128-1-TP-FC

120

0.34

24

> 0.5

< 150

1.0

UL, cUL

28

V1

RS

EB-221PS-1-TP

120

0.60

41

> 0.5

< 130

0.90

UL, cUL

38

L7

PS

EB-228-1-TP-PH

120

0.60

41

> 0.5

< 130

0.90

UL, cUL

38

L7

PH

EB-228-1-TP-PH-SL

120

0.60

41

> 0.5

< 130

0.90

UL, cUL

38

N1

PH

EB-228HE-UV-TP-PS 120~277 0.21~0.10

26

> 0.95

< 15

1.03

Pending

37

U4

PS

EB-228HE-UV-TP-PS 120~277

.40~0.17

48

> 0.98

< 10

1.02

Pending

36

U4

PS

EB-235HE-UV-TP-PS 120~277 0.40~0.17

48

> 0.98

< 10

1.02

Pending

36

U4

PS

2
1
1

EB-228-1-TP-PH-SL

120

0.70

120

0.41

EB-224HO-UV-TP-PS 120~277 0.23~0.11

50
28
28

0.5
< 130
> 0.5 < 150
> 0.95 < 12

0.80
1.0
0.96

UL, cUL
UL, cUL
UL, cUL

38

EB-139HO-1-TP

37

N1
N1
U4

PH
RS
PS

EB-239HO-UV-TP-PSws 120~277 0.24~0.12

29

> 0.92

< 12

1.10

UL, cUL

37

U4

PS

EB-224HO-UV-TP-PS 120~277 0.42~0.19

50

> 0.98

< 12

0.90

UL, cUL

36

U4

PS

EB-239HO-UV-TP-PSws 120~277 0.44~0.20

52

> 0.97

< 12

1.00

UL, cUL

36

U4

PS

28

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T5 Straight Lamps

28W

Lamp
Type

F28T5

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-135HE-1-TP

120

0.41

28

> 0.5

< 130

0.92

UL, cUL

28

N1

RS

EB-135HE-1-TP-PH

120

0.41

28

> 0.5

< 130

0.92

UL, cUL

28

N1

PH

EB-128-1-TP-FC

120

0.42

30

> 0.5

< 130

0.95

UL, cUL

28

V1

RS

EB-228HE-UV-TP-PS 120~277 0.28~0.12

33

> 0.98

< 10

1.04

PENDING

37

U4

PS

EPD-A28T5M

120~277 0.28~0.12

33

> 0.99

< 10

UL, cUL

47

AA1

IS

EPD-A35T5M

120~277 0.26~0.11

31

> 0.98

< 10

1.04

UL, cUL

47

AA1

IS

EPS-A28T5M

120~277 0.25~0.11

30

> 0.99

< 10

0.93

UL, cUL

31

AA1

IS

ESD-A35T5M

120~277 0.29~0.13

36

> 0.99

< 10/20

0.98

UL, cUL

48

AA2

PS

ESD-A35T5S

120~277 0.29~0.13

36

> 0.99

< 10/20

1.07

UL, cUL

48

AA2

PS

ESD-B35T5 ws

277~347 0.12~0.11

34

> 0.99

< 30

UL, cUL

48

AA2

PS

ESD-B35T5S

277~347 0.12~0.11

34

> 0.99

< 10

UL, cUL

48

AA2

PS

FSD-A18PBM ws

120~277 0.29~0.14

36

> 0.98

< 10

1.01

UL, cUL

AA23

PS

GSD-A18PBM ws

120~277 0.29~0.14

36

> 0.98

< 10

1.01

UL, cUL

AA24

PS

TSD-B35T5M

277~347 0.12~0.11

34

> 0.99

< 12

0.99

UL, cUL

AA1

PS

TSD-UV35T5M

120~277 0.29~0.13

36

> 0.98

< 10/20

1.07

UL, cUL

AA1

PS

EB-221PS-1-TP

120

0.70

50

> 0.5

< 130

0.80

UL, cUL

38

L7

PS

EB-228-1-TP-PH

120

0.70

50

> 0.5

< 130

0.80

UL, cUL

38

N1

PH

EB-228-1-TP-PH-SL

120

0.70

50

> 0.5

< 130

0.80

UL, cUL

38

N1

PH

EB-228HE-UV-TP-PS

120~277 0.53~0.23

64

> 0.98

< 10

1.03

PENDING

36

U4

PS

EPD-A28T5M

120~277 0.46~0.20

56

> 0.99

< 10

0.93

UL, cUL

12

AA1

IS

EPD-A35T5M

120~277 0.47~0.20

56

> 0.98

< 10

0.95

UL, cUL

12

AA1

IS

EPT-A28T5M

120~277 0.51~0.22

61

> 0.99

< 10

0.99

UL, cUL

50

AA1

IS

EPT-A35T5M

120~277 0.51~0.22

61

> 0.99

< 10

0.98

UL, cUL

50

AA1

IS

ESD-A35T5M

120~277 0.56~0.25

56

> 0.99

< 10

0.95

UL, cUL

49

AA2

PS

ESD-A35T5S

120~277 0.56~0.25

69

> 0.99

< 10

0.96

UL, cUL

49

AA2

PS

ESD-B35T5 ws

277~347 0.24~0.19

66

> 0.99

< 10

0.96

UL, cUL

49

AA2

PS

ESD-B35T5S

277~347 0.24~0.19

66

> 0.99

< 10

0.96

UL, cUL

49

AA2

PS

TSD-B35T5M

277~347 0.28~0.25

65

> 0.99

< 12

0.94

UL, cUL

AA1

PS

TSD-UV35T5M

120~277 0.56~0.25

68

> 0.99

< 10

0.95

UL, cUL

AA1

PS

EPQ-A28T5M

120~277 0.67~0.29

80

> 0.99

< 10

UL, cUL

51

AA1

IS

EPT-A28T5M

120~277 0.65~0.29

78

> 0.99

< 10

0.9

UL, cUL

13

AA1

IS

EPT-A35T5M

120~277 0.65~0.29

78

> 0.98

< 10

0.9

UL, cUL

13

AA1

IS

EPQ-A28T5M

120~277 0.87~0.38

104

> 0.99

< 10

0.93

UL, cUL

14

AA1

IS

EPQ-A35T5M

120~277 0.80~0.35

97

> 0.99

< 10

0.74

UL, cUL

14

AA1

IS

EPQ-335T5S

101

> 0.98

< 10

0.81

UL, cUL

14

AA3

IS

347

0.29

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A5

Electronic
Ballast

ElectronicBallasts

A6

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T5 Straight Lamps

Lamp
Watts

35W

35W

Lamp
Type

F35T5

F35T5HE

No. of
Lamps

Cat.
Number

EPD-A35T5M

ESD-A35T5S

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

120~277 0.31~0.13

37

120~277 0.35~0.16

44

> 0.98

< 10

0.95

UL. cUL

47

AA1

IS

> 0.98

< 10/15

1.02

UL. cUL

48

AA2

PS

ESD-B35T5ws

277~347 0.15~0.12

44

> 0.98

< 10/15

0.99

UL. cUL

48

AA2

PS

ESD-B35T5S

TSD-B35T5M

277~347 0.15~0.12

41

> 0.99

< 10/15

0.99

UL. cUL

48

AA2

PS

277~347 0.15~0.13

41

> 0.99

< 35

0.96

UL. cUL

AA1

PS

1
2

TSD-UV35T5M

120~277 0.35~0.16

36

> 0.98

< 10/20

1.03

UL. cUL

AA1

PS

EPD-A35T5M

120~277 0.55~0.24

67

> 0.99

< 10/15

0.88

UL. cUL

12

AA1

IS

EPT-A35T5M

120~277 0.85~0.37

102

> 0.98

< 10

0.98

UL. cUL

50

AA1

IS

ESD-A35T5S

120~277

0.69~0.3

84

> 0.99

< 10

0.95

UL. cUL

49

AA2

PS

ESD-B35T5ws

277~347 0.28~0.23

78

> 0.97

< 10

0.90

UL. cUL

49

AA2

PS

ESD-B35T5S

277~347 0.28~0.23

78

> 0.99

< 10

0.90

UL. cUL

49

AA2

PS

TSD-B35T5M

277~347 0.28~0.23

78

> 0.99

< 10

0.99

UL. cUL

AA1

PS

TSD-UV35T5M

EPT-A35T5M

39W

F39T5

F39T5 HO

120~277

Input
Current

0.69~0.3

120~277 0.85~0.37
347

85

> 0.99

< 10

0.92

UL. cUL

AA1

PS

> 0.98

< 10

0.90

UL. cUL

13

AA1

IS

134

> 0.98

< 10

0.80

UL. cUL

14

AA3

IS

118

> 0.99

< 10

0.77

UL. cUL

14

AA1

IS

34

> 0.50

< 130

0.88

UL. cUL

28

N1

RS

34

> 0.50

< 130

0.88

UL. cUL

28

N1

PH

< 10

1.00

PENDING

37

U4

PS

EPQ-335T5S

EPQ-A35T5M

EB-135HE-1-TPws

120

0.48

EB-135HE-1-TP-PH

120

0.48

EB-235HE-UV-TP-PS 120~277 0.34~0.15

41

> 0.98

EB-235HE-UV-TP-PS 120~277 0.67~0.28

0.39

120~277 0.99~0.43

Dimen Staring
-sions Method

102

80

> 0.98

< 10

1.00

PENDING

36

U4

PS

ESS-A54T5ws

120~277 0.35~0.14

43

> 0.99

< 10/15

0.82

UL. cUL

48

AA2

PS

EPD-A54T5M

120~277 0.69~0.32

87

> 0.98

< 10/15

1.02

UL. cUL

47

AA1

IS

ESD-A54T5ws

120~277 0.76~0.33

92

> 0.98

< 10/15

0.99

UL. cUL

49

AA4

PS

TSD-UV54T5M

120~277

0.7~0.32

85

> 0.99

< 10/15

UL. cUL

AA1

PS

ESD-B54T5ws

277~347

0.3~0.25

84

> 0.99

< 10

0.93

UL. cUL

49

AA4

PS

ESPQ-A54T5S

120~277 1.42~0.64

174

> 0.98

< 10/15

UL. cUL

42

AA5

PS

EB-139HO-1-TP

35

> 0.50

< 130

0.90

UL. cUL

28

N1

RS

EB-224HO-UV-TP-PS

120~277 0.33~0.15

39

> 0.97

< 12

0.90

UL. cUL

37

U4

PS

EB-239HO-UV-TP-PS

120~277 0.40~0.18

48

> 0.96

< 12

1.15

UL. cUL

37

U4

PS

EB-239HO-UV-TP-PS

120~277 0.78~0.34

94

> 0.98

< 10

1.12

UL. cUL

36

U4

PS

39W

Input
Volts

120

0.49

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T5 Straight Lamps

54W

Lamp
Type

F54T5
HO

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-154HO-1-TP

120

0.74

51

> 0.5

< 130

0.95

UL. cUL

28

N1

RS

EB-155-1-TP-SC*

120

0.82

59

> 0.5

< 130

1.00

UL. cUL

28

L8

RS

EB-254HO-UV-TP-PS 120 ~ 277 0.51~0.23

61

> 0.98

< 10

1.02

UL. cUL

37

U4

PS

EB-454HO-UV-TP-PS 120 ~ 277 0.52~0.25

63

> 0.91

< 20

1.02

PENDING

48

L10

PS

EPD-A54T5M

120 ~ 277 0.57~0.23

69

> 0.99

< 10

0.87

UL. cUL

47

AA1

IS

ESS-A54T5

120 ~ 277 0.45~0.2

55

> 0.98

< 10

0.85

UL. cUL

48

AA2

PS

TSD-UV54T5M

120 ~ 277 0.51~0.24

63

> 0.98

< 10/18

1.03

UL. cUL

AA1

PS

ESD-A54T5ws

120 ~ 277 0.5~0.23

61

> 0.98

< 10/15

0.99

UL. cUL

48

AA4

PS

ESD-B54T5

277 ~ 347 0.22~0.18

61

> 0.99

< 15

0.97

UL. cUL

48

AA4

PS

EB-254HO-UV-TP-PS 120 ~ 277 0.98~0.42

117

> 0.98

< 10

1.00

UL. cUL

36

U4

PS

EB-454HO-UV-TP-PS 120 ~ 277 0.98~0.44

116

> 0.97

< 15

1.00

PENDING

47

L10

PS

EPD-A54T5M

120 ~ 277 0.9~0.43

108

> 0.99

< 10

0.87

UL. cUL

12

AA1

IS

ESD-A54T5ws

120 ~ 277 0.97~0.43

117

> 0.98

< 10

0.99

UL. cUL

49

AA4

PS

TSD-UV54T5M

120 ~ 277 0.96~0.43

115

> 0.99

< 10/12

0.93

UL. cUL

AA1

PS

ESD-B54T5

277 ~ 347 0.43~0.34

119

> 0.99

< 10

0.93

UL. cUL

49

AA4

PS

EB-454HO-UV-TP-PS 120 ~ 277 1.42~0.62

170

> 0.98

< 15

1.02

PENDING

48

L10

PS

ESPQ-A54T5S

120 ~ 277 1.47~0.67

180

> 0.98

< 10/15

1.00

UL. cUL

51

AA5

PS

EB-454HO-UV-TP-PS 120 ~ 277 1.85~0.79

220

> 0.99

< 10

1.00

PENDING

47

L10

PS

ESPQ-A54T5S

231

> 0.98

< 10

0.98

UL. cUL

42

AA5

PS

120 ~ 277 1.92~0.86

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A7

Electronic
Ballast

ElectronicBallasts

A8

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps

Lamp
Watts

14W

14W

15W

Lamp
Type

F13T8

F14T8

F15T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

EB-126-1-TP-LC-TB

U2

RS

EB-126-1-TP-SL

N1

RS

EB-126-1-TP-SL-TB

U3

RS

EB-126-1-TP-SC *

L8

RS

EB-120-1-TP

120

0.24

15

> 0.50

< 150

1.1

UL, cUL

28

X1

RS

EB-120-1-TP-EMI

120

0.24

15

> 0.50

< 150

1.1

UL, cUL

28

L7

RS

EB-220-1-TP #

120

0.42

27

> 0.50

< 150

0.85

UL, cUL

30

L7

RS

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

EB-126-1-TP-LC-TB

U2

RS

EB-126-1-TP-SL

N1

RS

EB-126-1-TP-SL-TB

U3

RS

EB-126-1-TP-SC *

EB-132-2-TP-PIC-SL

277

0.07

19

EB-232RIS-1-TP-SL

120

0.32

EB-120-1-TP

120

0.26

EB-120-1-TP-EMI

120

EB-132-1-TP*

120

EB-220-1-TP #

EB-2C72-1-TP

2
2

120

120

0.27

0.27

16

17

> 0.50

> 0.50

< 160

1.1

< 150

1.0

UL,CSA

UL,CSA

28

28

L8

RS

0.98

< 10

1.05

UL, cUL

28

N3

RS

20

0.52

< 150

0.90

UL, cUL

31

N3

IS

17

> 0.50

< 150

1.1

UL, cUL

28

X1

RS

0.26

17

> 0.50

< 150

1.1

UL, cUL

28

L7

RS

0.27

17

> 0.50

< 150

1.1

UL, cUL

28

L7

RS

120

0.48

32

> 0.50

< 150

1.0

UL, cUL

30

L7

RS

120

0.45

29

> 0.50

< 160

0.80

UL, CSA

30

L1

RS

EB-232-1-TP-SL

120

0.45

29

> 0.50

< 160

0.80

UL, cUL

30

N1

RS

EB-232RIS-1-TP-SL

120

0.43

28

> 0.50

< 160

0.80

UL, cUL

30

N3

IS

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps
Lamp
Watts

F17T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

S1

RS

EB-126-1-TP-LC

L2

RS

EB-126-1-TP-LC-TB

U2

RS

EB-126-1-TPws

1
1

120

0.31

20

> 0.50

< 150

1.0

UL, CSA

28

EB-126-1-TP-SL

N1

RS

EB-126-1-TP-SL-TB

U3

RS

EB-126-1-TP-SC **

L8

RS

EB-132-1-TP

120

0.31

20

> 0.50

< 150

1.15

UL, cUL

28

L7

RS

EB-120-1-TP

120

0.29

19

> 0.50

< 150

1.15

UL, cUL

28

X1

RS

EB-120-1-TP-EMI

120

0.29

19

> 0.50

< 150

1.15

UL, cUL

28

L7

RS

EB-132-1-TP-PIC

120

0.18

22

> 0.99

< 12

1.0

UL, cUL

31

L3

IS

EB-232RIS-1-TP

120

0.37

21

> 0.50

< 160

0.97

UL, cUL

31

L5

IS

EB-132LBF-1-TP-PIC

120

0.15

17

> 0.98

< 10

0.90

UL, cUL

31

L5

IS

EB-132LBF-1-TP-PIC-SL

120

0.15

17

> 0.98

< 10

0.90

UL, cUL

31

L6

IS

EB-132LBF-2-TP-PIC

277

0.07

17

> 0.98

< 10

0.90

UL, cUL

31

L5

IS

EB-132LBF-2-TP-PIC-SL

277

0.07

17

> 0.98

< 10

0.90

UL, cUL

31

L6

IS

EB-132-2-TP-PIC-SL

277

0.08

21

> 0.98

< 10

0.95

UL, cUL

31

N3

RS

EB-132-UV-TP-SLws

120~277 0.18~0.08

21

> 0.96

< 12

1.0

UL, cUL

RS

EB-132-UV-TP-PIC

120~277 0.18~0.08

21

> 0.96

< 10

1.0

UL, cUL

31

IS

EB-132LBF-UV-TP-PIC 120~277 0.15~0.07

18

> 0.98

< 10

0.88

UL, cUL

31

IS

EB-132LBF-UV-TP-PIC-SL

120~277 0.15~0.07

18

> 0.98

< 10

0.88

UL, cUL

31

IS

EB-132EBF-UV-TP-PIC 120~277 0.14~0.06

17

> 0.97

< 12

0.77

UL, cUL

31

EB-232RIS-1-TP-SL

120

0.39

25

0.54

< 150

1.10

UL, cUL

31

L5

IS

EB-132EBF-1-TP-PIC

120

0.14

17

> 0.97

< 12

0.77

UL, cUL

31

L5

IS

EB-132EBF-2-TP-PIC

277

0.06

17

> 0.97

< 12

0.77

UL, cUL

31

L5

IS

EB-132HBF-1-TP-PIC

120

0.19

23

> 0.97

< 12

1.18

UL, cUL

31

L5

IS

EB-132HBF-2-TP-PIC

277

0.09

23

> 0.97

< 12

1.18

UL, cUL

31

L5

IS

EB-132HBF-UV-TP-PIC

23

> 0.97

< 12

1.18

UL, cUL

31

EB-232EBF-1-TP-PIC

120

0.17

18

> 0.97

< 12

0.88

UL, cUL

31

L5

IS

EB-232EBF-2-TP-PIC

277

0.07

18

> 0.97

< 12

0.88

UL, cUL

31

L5

IS

EB-232HBF-1-TP-PIC

120

0.22

27

> 0.97

< 12

1.40

UL, cUL

31

L5

IS

EB-232HBF-2-TP-PIC

277

0.17

27

> 0.97

< 12

1.40

UL, cUL

31

L5

IS

EB-232EBF-UV-TP-PIC 120~277 0.17~0.07

18

> 0.97

< 12

0.88

UL, cUL

31

IS

EB-232HBF-UV-TP-PIC

120~277 0.22~0.17

27

> 0.97

< 12

1.40

UL, cUL

31

IS

120~277 0.19~0.09

IS

IS

** replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

17W

Lamp
Type

A9

Electronic
Ballast

ElectronicBallasts

A10

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps

Lamp
Watts

17W

Lamp
Type

F17T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-220-1-TP #

120

0.54

37

> 0.50

< 150

1.02

UL, cUL

30

L7

RS

EB-232-1-TP-SL

120

0.60

36

> 0.50

< 160

0.95

UL, cUL

30

N1

RS

EB-232-UV-TP-SLws

120~277

0.34~0.1

40

> 0.97

< 10

1.0

UL, cUL

32

L4

RS

EB-232-UV-TP-PIC

120~277 0.33~0.14

39

> 0.98

< 10

1.0

UL, cUL

12

L3

IS

EB-232LBF-UV-TP-PIC 120~277 0.28~0.12

33

> 0.97

< 10

0.90

UL, cUL

12

L5

IS

EB-232LBF-UV-TP-PIC-SL *

120~277 0.28~0.12

33

> 0.97

< 10

0.90

UL, cUL

12

L6

IS

EB-232EBF-UV-TP-PIC 120~277 0.24~0.11

29

> 0.97

< 12

0.77

UL, cUL

12

L5

IS

EB-2C72-1-TP

120

0.60

36

> 0.50

< 160

0.95

UL, CSA

30

L1

RS

EB-232-1-TP-PIC

120

0.33

40

> 0.99

< 10

1.00

UL, cUL

12

L3

IS

EB-232RIS-1-TP ws

120

0.51

32

> 0.50

< 150

0.84

UL, cUL

12

L5

IS

EB-232LBF-1-TP-PICws *

120

0.28

32

> 0.98

< 10

0.90

UL, cUL

12

L5

IS

EB-232LBF-1-TP-PIC-SL *

120

0.28

32

> 0.98

< 10

0.90

UL, cUL

12

L6

IS

EB-232LBF-2-TP-PIC *

277

0.12

32

> 0.98

< 10

0.90

UL, cUL

12

L5

IS

EB-232LBF-2-TP-PIC-SL *

277

0.12

32

> 0.98

< 10

0.90

UL, cUL

12

L6

IS

EB-232RIS-1-TP-SL

120

0.50

34

0.54

< 150

0.93

UL, cUL

12

N3

IS

EB-232EBF-1-TP-PIC

120

0.24

29

> 0.97

< 12

0.77

UL, cUL

12

L5

IS

EB-232EBF-2-TP-PIC

277

0.11

29

> 0.97

< 12

0.77

UL, cUL

12

L5

IS

EB-232HBF-1-TP-PIC

120

0.35

43

> 0.97

< 12

1.18

UL, cUL

12

L3

IS

EB-232HBF-2-TP-PIC

277

0.16

43

> 0.97

< 12

1.18

UL, cUL

12

L3

IS

EB-232HBF-UV-TP-PIC

43

> 0.97

< 12

1.18

UL, cUL

12

L5

IS

EB-332EBF-1-TP-PIC

120

0.29

34

> 0.97

< 12

0.88

PENDING

12

L5

IS

EB-332EBF-2-TP-PIC

277

0.13

34

> 0.95

< 12

0.88

PENDING

12

L5

IS

EB-332EBF-UV-TP-PIC 120~277 0.29~0.13

34

> 0.97

< 12

0.88

UL, cUL

12

L3

IS

EB-332HBF-1-TP-PIC

EB-332HBF-2-TP-PIC

EB-332HBF-UV-TP-PIC

EPD-132T8M

120~277 0.35~0.16

120

0.38

46

> 0.97

< 12

1.25

PENDING

12

L3

IS

277

0.18

46

> 0.95

< 12

1.25

PENDING

12

L3

IS

46

> 0.97

< 12

1.25

UL, cUL

12

L3

IS

33

> 0.99

< 10

0.95

UL, cUL

12

AA1

IS

120~277 0.38~0.18
120

0.26

** replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps

17W

Lamp
Type

F17T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

347

0.06

28

> 0.98

< 10

0.88

UL, cUL

12

AA1

IS

347

0.10

36

> 0.99

< 10

1.03

UL, cUL

12

AA1

IS

EPD-317T8M

EPD-332T8M

EPD-A32T8M

EPT-132T8M

EPT-332T8M

EPT-A32T8M

ESD-332T8M

ESD-A32T8M

EB-332-1-TP-PIC

EB-332-UV-TP-PIC

EB-432RIS-1-TPws

120

EB-332LBF-1-TP-PIC

EB-332LBF-2-TP-PIC

Dimen Staring
-sions Method

33

> 0.99

< 10

0.95

UL, cUL

12

AA1

IS

120

0.30

36

> 0.99

< 15

1.05

UL, cUL

12

AA1

IS

347

0.11

38

> 0.95

< 35

1.05

UL, cUL

12

AA1

IS

37

> 0.97

< 15/35

1.05

UL, cUL

12

AA1

IS

38

> 0.97

< 15

0.97

UL, cUL

AA1

RS

38

> 0.98

< 15/35

0.96

UL, cUL

AA1

RS

57

> 0.99

< 10

UL, cUL

13

L3

IS

56

> 0.98

< 10

UL, cUL

13

L3

IS

0.82

46

> 0.50

< 150

0.87

UL, cUL

13

L5

IS

120

0.40

47

> 0.98

< 10

0.90

UL, cUL

13

L5

IS

277

0.18

47

> 0.98

< 10

0.90

UL, cUL

13

L5

IS

EB-332EBF-1-TP-PIC

120

0.35

42

> 0.97

< 12

0.81

UL, cUL

13

L5

IS

EB-332EBF-2-TP-PIC

277

0.16

42

> 0.97

< 12

0.81

UL, cUL

13

L5

IS

EB-332EBF-UV-TP-PIC 120~277 0.35~0.16

42

> 0.97

< 12

0.81

UL, cUL

13

L5

IS

EB-332HBF-1-TP-PIC

EB-332HBF-2-TP-PIC

EB-332HBF-UV-TP-PIC

120~277 0.48~0.22

EB-332LBF-UV-TP-PIC

120~277 0.43~0.19

EB-432EBF-1-TP-PIC

120

EB-432EBF-2-TP-PIC

277

EB-432EBF-UV-TP-PIC 120~277

EP6-132T8HO-S

120

EP6-332T8HO

347

EP6-A32T8HO

EPQ-132T8M

120

EPQ-332T8M

347

120~277 0.28~0.12

120~277 0.30~0.15
347

0.11

120~277 0.30~0.14
120

0.48

120~277 0.48~0.21

120

0.48

58

> 0.97

< 12

1.18

UL, cUL

13

L3

IS

277

0.22

58

> 0.97

< 12

1.18

UL, cUL

13

L3

IS

58

> 0.97

< 12

1.18

UL, cUL

13

L3

IS

51

> 0.97

< 10

0.90

UL, cUL

13

L5

IS

0.36

43

> 0.97

< 12

0.87

UL, cUL

13

L5

IS

0.17

43

> 0.97

< 12

0.87

UL, cUL

13

L5

IS

43

> 0.97

< 12

0.87

UL, cUL

13

L5

IS

0.42

56

> 0.99

< 10

1.32

UL, cUL

54

AA22

IS

0.20

69

> 0.95

< 25

1.23

UL, cUL

54

AA22

IS

56

> 0.99

< 10

1.32

UL, cUL

54

AA1

IS

0.40

48

> 0.99

< 15

UL, cUL

52

AA1

IS

0.15

51

> 0.99

< 15

UL, cUL

52

AA1

IS

120~277 0.42~0.20

** replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A11

Electronic
Ballast

ElectronicBallasts

A12

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps

Lamp
Watts

17W

Lamp
Type

F17T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

51

> 0.92

< 15/40

1.01

UL, cUL

52

AA1

IS

EPQ-A32T8M

EPT-132T8M

120

0.38

45

> 0.96

< 10

0.96

UL, cUL

13

AA1

IS

EPT-332T8M

347

0.14

48

> 0.98

< 25

0.96

UL, cUL

13

AA1

IS

EPT-A32T8M

48

> 0.98

< 10

0.96

UL, cUL

13

AA1

IS

ESPQ-132T8HO

ESPQ-332T8HO

ESPQ-A32T8HO

EB-432-1-TP-PIC

120

EB-432RIS-1-TPws

4
4

120~277 0.42~0.21

120~277 0.40~0.20
120

0.50

60

> 0.99

< 10

0.77

UL, cUL

57

AA29

RS

347

0.18

61

> 0.99

< 10

0.77

UL, cUL

57

AA29

RS

63

> 0.99

< 10

0.77

UL, cUL

57

AA3

RS

0.61

73

> 0.99

< 10

1.00

UL, cUL

14

L3

IS

120

0.96

60

> 0.50

< 140

0.88

UL, cUL

14

L5

IS

EB-432LBF-1-TP-PICws ***

120

0.51

60

> 0.98

< 10

0.90

UL, cUL

14

L5

IS

EB-432LBF-2-TP-PIC ***

277

0.22

60

> 0.98

< 10

0.90

UL, cUL

14

L5

IS

EB-432EBF-1-TP-PIC

120

0.43

52

> 0.97

< 12

0.81

UL, cUL

14

L5

IS

EB-432EBF-2-TP-PIC

277

0.20

52

> 0.97

< 12

0.81

UL, cUL

14

L5

IS

EB-432-UV-TP-PIC

120~277 0.60~0.26

69

> 0.95

< 10

1.0

UL, cUL

14

L3

IS

EB-432LBF-UV-TP-PIC **

120~277 0.51~0.23

61

> 0.97

< 10

0.90

UL, cUL

14

L5

IS

EB-432EBF-UV-TP-PIC 120~277 0.43~0.20

52

> 0.97

< 12

0.81

UL, cUL

14

L5

IS

EP6-332T8HO

347

0.27

92

> 0.95

< 25

1.35

UL, cUL

55

AA22

IS

EPQ-132T8M

120

0.48

57

> 0.99

< 15

0.92

UL, cUL

53

AA1

IS

EPQ-332T8M

347

0.18

61

> 0.99

< 10

0.92

UL, cUL

14

AA1

IS

EPQ-A32T8M

60

> 0.93

< 15/35

0.92

UL, cUL

14

AA1

IS

ESPQ-132T8HO

120

0.67

80

> 0.99

< 10

0.75

UL, cUL

42

AA29

RS

ESPQ-332T8HO

347

0.22

77

> 0.99

< 10

0.75

UL, cUL

42

AA29

RS

ESPQ-A32T8HO

80

> 0.99

< 10

0.75

UL, cUL

42

AA3

RS

EP6-132T8HO-S

120

0.84

112

> 0.99

< 10

1.32

UL, cUL

56

AA22

IS

EP6-332T8HO

347

0.40

138

> 0.98

< 25

1.23

UL, cUL

56

AA22

IS

EP6-A32T8HO

112

> 0.99

< 10

1.32

UL, cUL

56

AA22

IS

120~277 0.53~0.23

120~277 0.48~0.24

120~277 0.67~0.29

120~277 0.84~0.40

*** cap off one BLUE wire for three lamp application.
** replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps

Lamp
Type

F18T8 24

F18T8 26

No. of
Lamps

F18T8 30

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-120-1-TP

120

0.27

18

> 0.50

< 150

0.95

UL, cUL

28

X1

RS

EB-120-1-TP-EMI

120

0.27

18

> 0.50

< 150

0.95

UL, cUL

28

L7

RS

EB-220-1-TP #

120

0.50

34

> 0.50

< 150

0.92

UL, cUL

30

L7

RS

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

EB-126-1-TP-LC-TBws

U2

RS

EB-126-1-TP-LC-TBws

N1

RS

EB-126-1-TP-SL

U3

RS

EB-126-1-TP-SL-TBws

L8

RS

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

EB-126-1-TP-LC-TBws

U2

RS

EB-126-1-TP-SL

N1

RS

EB-126-1-TP-SL-TBws

U3

RS

EB-126-1-TP-SC *

L8

RS

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

U2

RS

N1

RS

EB-126-1-TP-SL-TBws

U3

RS

EB-126-1-TP-SC *

L8

RS

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

U2

RS

N1

RS

EB-126-1-TP-SL-TBws

U3

RS

EB-126-1-TP-SC *

L8

RS

18W

F18T8 28

Cat.
Number

EB-126-1-TP-LC-TBws

EB-126-1-TP-SL

EB-126-1-TP-LC-TBws

EB-126-1-TP-SL

120

120

120

120

0.27

0.28

0.29

0.30

17

18

18

19

> 0.50

> 0.50

> 0.50

> 0.50

< 160

0.95

< 160

1.0

< 160

1.0

< 160

1.05

UL, cUL

UL, cUL

UL, cUL

UL, cUL

28

28

28

28

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A13

Electronic
Ballast

A14

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps
Lamp
Type

ElectronicBallasts

Lamp
Watts

25W

F25T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-126-1-TPws

S1

RS

EB-126-1-TP-LC

L2

RS

EB-126-1-TP-LC-TBws

U2

RS

EB-126-1-TP-SL

N1

RS

EB-126-1-TP-SL-TBws

U3

RS

EB-126-1-TP-SC *

L8

RS

EB-132-1-TP

120

0.41

28

> 0.50

< 130

1.05

UL, cUL

28

L7

RS

EB-132-1-TP-PIC

120

0.25

30

> 0.99

< 10

1.0

UL, cUL

31

L3

IS

EB-132-UV-TP-SL

120~277 0.24~0.10

28

> 0.98

< 10

1.0

UL, cUL

L4

RS

EB-132-UV-TP-PIC

120~277 0.26~0.11

30

> 0.98

< 10

1.0

UL, cUL

31

L3

IS

EB-132LBF-UV-TP-PIC

120~277 0.20~0.09

24

> 0.99

< 10

0.90

UL, cUL

31

L5

IS

EB-132LBF-UV-TP-PIC-SL

120~277 0.20~0.09

24

> 0.99

< 10

0.90

UL, cUL

31

L6

IS

EB-132EBF-UV-TP-PIC

120~277 0.19~0.08

23

> 0.98

< 10

0.77

UL, cUL

31

L5

IS

EB-132HBF-UV-TP-PIC

120~277 0.27~0.12

32

> 0.98

< 10

1.18

UL, cUL

31

L5

IS

EB-232RIS-1-TPws

120

0.45

27

> 0.50

< 150

0.95

UL, cUL

31

L5

IS

EB-132LBF-1-TP-PIC

120

0.20

24

> 0.99

< 10

0.90

UL, cUL

31

L5

IS

EB-132LBF-1-TP-PIC-SL

120

0.20

24

> 0.99

< 10

0.90

UL, cUL

31

L6

IS

EB-132LBF-2-TP-PIC

277

0.09

24

> 0.99

< 10

0.90

UL, cUL

31

L5

IS

EB-132LBF-2-TP-PIC-SL

277

0.09

24

> 0.99

< 10

0.90

UL, cUL

31

L6

IS

EB-132-2-TP-PIC-SL

277

0.10

27

> 0.98

< 10

0.95

UL, cUL

31

N3

IS

EB-232RIS-1-TP-SL

120

0.47

31

0.57

< 150

1.05

UL, cUL

31

N3

IS

EB-132EBF-1-TP-PIC

120

0.19

23

> 0.98

< 10

0.77

UL, cUL

31

L5

IS

EB-132EBF-2-TP-PIC

277

0.08

23

> 0.98

< 10

0.77

UL, cUL

31

L5

IS

EB-132HBF-1-TP-PIC

120

0.27

32

> 0.98

< 10

1.18

UL, cUL

31

L3

IS

EB-132HBF-2-TP-PIC

277

0.12

32

> 0.98

< 10

1.18

UL, cUL

31

L3

IS

EB-232EBF-1-TP-PIC

120

0.21

25

> 0.98

< 10

0.88

UL, cUL

31

L5

IS

EB-232EBF-2-TP-PIC

277

0.09

25

> 0.98

< 10

0.88

UL, cUL

31

L5

IS

EB-232EBF-UV-TP-PIC 120~277 0.21~0.09

25

> 0.98

< 10

0.88

UL, cUL

31

L5

IS

EB-232HBF-1-TP-PIC

120

0.29

39

> 0.98

< 10

1.34

UL, cUL

31

L3

IS

EB-232HBF-2-TP-PIC

277

0.14

39

> 0.98

< 10

1.34

UL, cUL

31

L3

IS

EB-232HBF-UV-TP-PIC

39

> 0.98

< 10

1.34

UL, cUL

31

L3

IS

EPD-132T8M

120

0.25

30

> 0.99

< 10

0.99

UL, cUL

31

AA1

IS

EPD-332T8M

347

0.08

30

> 0.98

< 10

1.13

UL, cUL

31

AA1

IS

EPD-A32T8M

30

> 0.99

< 10/15

1.13

UL, cUL

31

AA1

IS

EPS-132T8M

120

0.25

30

> 0.99

< 10

1.13

UL, cUL

31

AA1

IS

ESD-332T8M

347

0.08

30

> 0.98

< 15

1.1

UL, cUL

AA1

RS

120

0.41

120~277 0.29~0.14

120~277 0.25~0.11

28

> 0.50

< 130

0.95

UL, cUL

28

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps

25W

Lamp
Type

F25T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

ESD-A32T8M

30

> 0.99

< 10/20

1.1

UL, cUL

AA1

RS

EB-2C72-1-TP

120

0.72

48

> 0.50

< 150

0.95

UL, CSA

30

L1

RS

EB-232-1-TP-SL

120

0.72

48

> 0.50

< 150

0.95

UL, cUL

30

N1

RS

EB-240-1-TP

120

0.81

52

> 0.50

< 150

1.05

UL, cUL

30

L1

RS

EB-232-1-TP-PIC

120

0.46

55

> 0.99

< 10

1.0

UL, cUL

12

L3

IS

EB-232RIS-1-TP

120

0.64

42

> 0.50

< 130

0.81

UL, cUL

12

L5

IS

EB-232LBF-1-TP-PICws **

120

0.39

46

> 0.99

< 10

0.90

UL, cUL

12

L5

IS

EB-232LBF-1-TP-PIC-SL **

120

0.39

46

> 0.99

< 10

0.90

UL, cUL

12

L6

IS

EB-232LBF-2-TP-PIC **

277

0.17

46

> 0.99

< 10

0.90

UL, cUL

12

L5

IS

EB-232LBF-2-TP-PIC-SL **

277

0.17

46

> 0.99

< 10

0.90

UL, cUL

12

L6

IS

EB-232RIS-1-TP-SL

120

0.65

47

> 0.59

< 150

0.90

UL, cUL

12

N3

IS

EB-232EBF-1-TP-PIC

120

0.33

40

> 0.98

< 10

0.80

UL, cUL

12

L5

IS

EB-232EBF-2-TP-PIC

277

0.15

40

> 0.98

< 10

0.80

UL, cUL

12

L5

IS

EB-232HBF-1-TP-PIC

120

0.48

57

> 0.98

< 10

1.18

UL, cUL

12

L3

IS

EB-232HBF-2-TP-PIC

277

0.21

57

> 0.98

< 10

1.18

UL, cUL

12

L3

IS

EB-232-UV-TP-SL

120~277 0.47~0.20

55

> 0.98

< 10

1.0

UL, cUL

32

L4

RS

EB-232-UV-TP-PIC

120~277 0.47~0.20

55

> 0.98

< 10

1.0

UL, cUL

12

L3

IS

EB-232LBF-UV-TP-PIC

120~277 0.39~0.17

46

> 0.99

< 10

0.90

UL, cUL

12

L5

IS

EB-232LBF-UV-TP-PIC-SL *

120~277 0.39~0.17

46

> 0.99

< 10

0.90

UL, cUL

12

L6

IS

EB-232EBF-UV-TP-PIC

120~277 0.33~0.15

40

> 0.98

< 10

0.80

UL, cUL

12

L5

IS

EB-232HBF-UV-TP-PIC

120~277 0.48~0.21

57

> 0.98

< 10

1.18

UL, cUL

12

L5

IS

EB-332EBF-1-TP-PIC

120

0.38

45

> 0.98

< 10

0.87

UL, cUL

13

L5

IS

EB-332EBF-2-TP-PIC

277

0.17

45

> 0.98

< 10

0.87

UL, cUL

13

L5

IS

EB-332HBF-1-TP-PIC

120

0.52

62

> 0.98

< 10

1.24

UL, cUL

13

L3

IS

EB-332HBF-2-TP-PIC

277

0.23

62

> 0.98

< 10

1.24

UL, cUL

13

L3

IS

EB-332EBF-UV-TP-PIC 120~277

45

> 0.98

< 10

0.87

UL, cUL

12

L3

IS

EB-332HBF-UV-TP-PIC

120~277

62

> 0.98

< 10

1.24

UL, cUL

12

L3

IS

EPD-132T8M

120

0.37

46

> 0.99

< 10

0.90

UL, cUL

12

AA1

IS

EPD-332T8M

347

0.13

47

> 0.99

< 10

0.95

UL, cUL

12

AA1

IS

EPD-A32T8M

46

> 0.99

< 10

0.90

UL, cUL

12

AA1

IS

120~277 0.25~0.13

120~277 0.37~0.16

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
# add EMI for model with EMI filter, comply with FCC Class B.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A15

Electronic
Ballast

ElectronicBallasts

A16

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps

Lamp
Watts

25W

Lamp
Type

F25T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EPQ-332T8M

347

0.15

51

> 0.98

< 20

1.03

UL, cUL

12

AA1

IS

EPT-132T8M

120

0.41

49

> 0.99

< 10

1.03

UL, cUL

12

AA1

IS

EPT-A32T8M

51

> 0.99

< 10

1.02

UL, cUL

12

AA1

IS

ESD-332T8M

52

> 0.99

< 10

0.95

UL, cUL

AA1

RS

ESD-A32T8M

50

> 0.98

< 10/15

0.93

UL, cUL

AA1

RS

120~277 0.42~0.20
347

0.15

120~277 0.40~0.19

EB-332-1-TP-PIC

120

0.67

80

> 0.99

< 10

1.0

UL, cUL

13

L3

IS

EB-432RIS-1-TPws

120

1.04

63

> 0.50

< 130

0.84

UL, cUL

13

L5

IS

EB-332LBF-1-TP-PIC

120

0.58

69

> 0.99

< 10

0.90

UL, cUL

13

L5

IS

EB-332LBF-2-TP-PIC

277

0.26

69

> 0.99

< 10

0.90

UL, cUL

13

L5

IS

EB-332EBF-1-TP-PIC

120

0.48

57

> 0.98

< 10

0.80

UL, cUL

13

L5

IS

EB-332EBF-2-TP-PIC

277

0.21

57

> 0.98

< 10

0.80

UL, cUL

13

L5

IS

EB-332EBF-UV-TP-PIC 120~277 0.48~0.21

57

> 0.98

< 10

0.80

UL, cUL

13

L5

IS

EB-332HBF-1-TP-PIC

120

0.69

92

> 0.98

< 10

1.18

UL, cUL

13

L3

IS

EB-332HBF-2-TP-PIC

277

0.30

92

> 0.98

< 10

1.18

UL, cUL

13

L3

IS

EB-332HBF-UV-TP-PIC 120~277 0.69~0.30

92

> 0.98

< 10

1.18

UL, cUL

13

L3

IS

EB-332LBF-UV-TP-PIC 120~277 0.58~0.26

70

> 0.98

< 10

0.90

UL, cUL

13

L5

IS

EB-332-UV-TP-PIC

80

> 0.98

< 10

1.0

UL, cUL

13

L3

IS

EB-432EBF-1-TP-PIC

120

0.51

60

> 0.98

< 10

0.85

UL, cUL

13

L5

IS

EB-432EBF-2-TP-PIC

277

0.23

60

> 0.98

< 10

0.85

UL, cUL

13

L5

IS

EB-432EBF-UV-TP-PIC 120~277 0.51~0.23

60

> 0.98

< 10

0.85

UL, cUL

13

L5

IS

EB-432-1-TP-PIC

120

0.89

106

> 0.99

< 10

1.0

UL, cUL

14

L3

IS

EB-432RIS-1-TPws

120

1.22

77

> 0.50

< 130

0.80

UL, cUL

14

L5

IS

EB-432LBF-1-TP-PICws **

120

0.74

88

> 0.99

< 10

0.90

UL, cUL

14

L5

IS

EB-432LBF-1-TP-PICws **

120

0.32

88

> 0.99

< 10

090

UL, cUL

14

L5

IS

EB-432EBF-1-TP-PICws

120

0.60

72

> 0.98

< 10

0.80

UL, cUL

14

L5

IS

EB-432EBF-2-TP-PIC

277

0.27

72

> 0.97

< 10

0.80

UL, cUL

14

L5

IS

120~277 0.68~0.29

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps

30W

Lamp
Type

F30T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

120

0.29

35

> 0.99

< 10

1.08

UL, cUL

31

AA1

IS

347

0.10

36

> 0.99

< 10

1.11

UL, cUL

31

AA1

IS

35

> 0.99

< 10/15

1.08

UL, cUL

31

AA1

IS

36

> 0.96

< 15

1.09

UL, cUL

AA1

RS

35

> 0.99

< 10/15

1.08

UL, cUL

AA1

RS

EPD-132T8M

EPD-332T8M

EPD-A32T8M

ESD-332T8M

ESD-A32T8M

EPD-132T8M

EPD-332T8M

EPD-A32T8M

ESD-332T8M

ESD-A32T8M

120~277 0.46~0.24

EP6-A32T8HO

120~277 0.87~0.38

ESPQ-132T8HO

120

0.86

ESPQ-332T8HO

347

ESPQ-132T8HO

ESPQ-332T8HO

EP6-A32T8HO

120~277 0.29~0.12
347

0.16

120~277 0.29~0.16

Dimen Staring
-sions Method

120

0.47

56

> 0.99

< 10

0.93

UL, cUL

12

AA1

IS

347

0.16

56

> 0.99

< 10

0.96

UL, cUL

12

AA1

IS

56

> 0.99

< 10

0.93

UL, cUL

12

AA1

IS

56

> 0.98

< 20

0.93

UL, cUL

AA1

RS

56

> 0.98

< 10/15

0.93

UL, cUL

AA1

RS

104

> 0.99

< 10

1.2

UL, cUL

54

AA22

IS

103

> 0.99

< 10

1.13

UL, cUL

57

AA29

RS

0.31

106

> 0.99

< 10

1.17

UL, cUL

57

AA29

RS

120

1.11

133

> 0.99

< 10

1.1

UL, cUL

42

AA29

RS

347

0.41

140

> 0.99

< 10

1.16

UL, cUL

42

AA29

RS

208

> 0.99

< 10

1.2

UL, cUL

56

AA22

IS

120~277 0.47~0.20
347

0.24

120~277 1.73~0.76

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A17

Electronic
Ballast

A18

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps
Lamp
Type

ElectronicBallasts

Lamp
Watts

32W

F32T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-126-1-TPws

120

0.51

35

> 0.50

< 130

1.1

UL, cUL

28

S1

RS

EB-126-1-TP-LC

120

0.51

35

> 0.50

< 130

1.1

UL, cUL

28

L2

RS

EB-126-1-TP-LC-TBws

120

0.51

35

> 0.50

< 130

1.1

UL, cUL

28

U2

RS

EB-126-1-TP-SL

120

0.51

35

> 0.50

< 130

1.1

UL, cUL

28

N1

RS

EB-126-1-TP-SL-TBws

120

0.51

35

> 0.50

< 130

1.1

UL, cUL

28

U3

RS

EB-126-1-TP-SC *

120

0.51

35

> 0.50

< 130

1.1

UL, cUL

28

L8

RS

EB-132-1-TP

120

0.48

32

> 0.50

< 130

0.95

UL, cUL

28

L7

RS

EB-132-1-TP-PIC

120

0.33

39

> 0.99

< 10

1.2

UL, cUL

31

L3

IS

EB-132-2-TP-PIC-SL

277

0.12

33

> 0.98

< 10

1.0

UL, cUL

28

N3

RS

EB-132EBF-1-TP-PIC

120

0.23

27

> 0.99

< 10

0.77

UL, cUL

31

L5

IS

EB-132EBF-2-TP-PIC

277

0.10

27

> 0.99

< 10

0.77

UL, cUL

31

L5

IS

EB-132HBF-1-TP-PIC

120

0.32

41

> 0.99

< 10

1.18

UL, cUL

31

L3

IS

EB-132HBF-2-TP-PIC

277

0.15

41

> 0.99

< 10

1.18

UL, cUL

31

L3

IS

EB-132LBF-1-TP-PIC

120

0.26

30

> 0.99

< 10

0.88

UL, cUL

31

L5

IS

EB-132LBF-1-TP-PIC-SL

120

0.26

30

> 0.99

< 10

0.88

UL, cUL

31

L6

IS

EB-132LBF-2-TP-PIC

277

0.11

30

> 0.99

< 10

0.88

UL, cUL

31

L5

IS

EB-132LBF-2-TP-PIC-SL

277

0.11

30

> 0.99

< 10

0.88

UL, cUL

31

L6

IS

EB-132-UV-TP-SLws

120~277 0.30~0.13

35

> 0.98

< 10

1.0

UL, cUL

L4

RS

EB-132-UV-TP-PIC

120~277 0.31~0.14

37

> 0.98

< 10

1.0

UL, cUL

31

L3

IS

EB-132LBF-UV-TP-PIC 120~277 0.25~0.11

30

> 0.99

< 10

0.88

UL, cUL

31

L5

IS

EB-132LBF-UV-TP-PIC-SL

120~277 0.25~0.11

30

> 0.99

< 10

0.88

UL, cUL

31

L6

IS

EB-132EBF-UV-TP-PIC 120~277 0.23~0.10

27

> 0.99

< 10

0.77

UL, cUL

31

L5

IS

EB-132HBF-UV-TP-PIC 120~277 0.32~0.15

41

> 0.99

< 10

1.18

UL, cUL

31

L3

IS

EPD-132T8M

120

0.30

36

> 0.99

< 10

1.06

UL, cUL

31

AA1

IS

EPD-332T8M

347

0.10

37

> 0.99

< 10

1.08

UL, cUL

31

AA1

IS

EPD-A32T8M

EPS-132T8M

ESD-332T8M

ESD-A32T8M

120~277 0.30~0.15

EB-232EBF-UV-TP-PIC

120~277 0.26~0.12

EB-232EBF-1-TP-PIC

120

0.26

EB-232EBF-2-TP-PIC

277

EB-232HBF-1-TP-PIC

120

EB-232HBF-2-TP-PIC

277

EB-232HBF-UV-TP-PIC

EB-232RIS-1-TPws

120

EB-232RIS-1-TP-SL

120

120~277 0.30~0.13

36

> 0.99

< 10

1.06

UL, cUL

31

AA1

IS

120

0.28

33

> 0.99

< 10

0.9

UL, cUL

31

AA1

IS

347

0.11

37

> 0.99

< 10

1.06

UL, cUL

AA1

RS

36

> 0.97

< 10/15

1.05

UL, cUL

AA1

RS

32

> 0.99

< 10

0.85

UL, cUL

31

L5

IS

32

> 0.99

< 10

0.85

UL, cUL

31

L5

IS

0.12

32

> 0.99

< 10

0.85

UL, cUL

31

L5

IS

0.39

46

> 0.99

< 10

1.42

UL, cUL

31

L3

IS

0.18

46

> 0.99

< 10

1.42

UL, cUL

31

L3

IS

46

> 0.99

< 10

1.42

UL, cUL

31

L3

IS

0.55

35

> 0.50

< 150

1.1

UL, cUL

31

L5

IS

0.55

37

0.57

< 150

1.00

UL, cUL

31

N3

IS

120~277 0.39~0.18

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps
Lamp
Watts

F32T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

EB-2C72-1-TP

120

0.89

62

> 0.50

< 130

0.97

UL, CSA

30

L1

RS

EB-232-1-TP-SL

120

0.89

62

> 0.50

< 130

0.90

UL, cUL

30

N1

RS

EB-240-1-TP

120

1.0

68

> 0.50

< 150

1.05

UL, cUL

30

L1

RS

EB-232-1-TP-PIC

120

0.62

74

> 0.99

< 10

1.0

UL, cUL

12

L3

IS

EB-232EBF-UV-TP-PIC 120~277 0.42~0.18

50

> 0.99

< 10

0.77

UL, cUL

12

L5

IS

EB-232EBF-1-TP-PIC

120

0.42

76

> 0.99

< 10

0.77

UL, cUL

12

L5

IS

EB-232EBF-2-TP-PIC

277

0.18

76

> 0.99

< 10

0.77

UL, cUL

12

L5

IS

EB-232HBF-1-TP-PIC

120

0.63

50

> 0.99

< 10

1.18

UL, cUL

12

L3

IS

EB-232HBF-2-TP-PIC

277

0.28

50

> 0.99

< 10

1.18

UL, cUL

12

L3

IS

EB-232HBF-UV-TP-PIC 120~277 0.63~0.28

76

> 0.99

< 10

1.18

UL, cUL

12

L3

IS

EB-332HBF-UV-TP-PIC 120~277 0.68~0.30

81

> 0.99

< 10

1.30

UL, cUL

12

L3

IS

EB-232LBF-1-TP-PICws **

120

0.49

58

> 0.99

< 10

0.88

UL, cUL

12

L5

IS

EB-232LBF-1-TP-PIC-SL **

120

0.49

58

> 0.99

< 10

0.88

UL, cUL

12

L6

IS

EB-232LBF-2-TP-PIC **

277

0.22

58

> 0.99

< 10

0.88

UL, cUL

12

L5

IS

EB-232LBF-2-TP-PIC-SL **

277

0.22

58

> 0.99

< 10

0.88

UL, cUL

12

L6

IS

EB-232LBF-UV-TP-PIC 120~277 0.49~0.22

59

> 0.99

< 10

0.88

UL, cUL

12

L5

IS

EB-232LBF-UV-TP-PIC-SL *

120~277 0.49~0.22

59

> 0.99

< 10

0.88

UL, cUL

12

L6

IS

EB-232RIS-1-TPws

120

0.79

54

> 0.50

< 120

0.83

UL, cUL

12

L5

IS

EB-232RIS-1-TP-SL

120

0.78

57

> 0.60

< 150

0.88

UL, cUL

12

N3

IS

EB-332EBF-1-TP-PIC

120

0.48

57

> 0.99

< 10

0.86

UL, cUL

12

L5

IS

EB-332EBF-2-TP-PIC

277

0.21

57

> 0.99

< 10

0.86

UL, cUL

12

L5

IS

EB-332EBF-UV-TP-PIC 120~277 0.48~0.21

57

> 0.99

< 10

0.86

UL, cUL

12

L5

IS

EB-332HBF-1-TP-PIC

120

0.68

81

> 0.99

< 10

1.30

UL, cUL

12

L3

IS

EB-332HBF-2-TP-PIC

277

0.30

81

> 0.99

< 10

1.30

UL, cUL

12

L3

IS

EPD-132T8M

120

0.48

57

> 0.99

< 10

0.88

UL, cUL

12

AA1

IS

EPD-332T8M

347

0.18

57

> 0.99

< 10

0.88

UL, cUL

12

AA1

IS

EPD-A32T8M

EPT-132T8M

EPT-332T8M

EPT-A32T8M

120~277 0.53~0.25

ESD-A32T8M

120~277 0.52~0.23

EB-332-1-TP-PIC

120

0.92

EB-332EBF-1-TP-PIC

120

0.62

EB-332EBF-2-TP-PIC

277

0.27

EB-332EBF-UV-TP-PIC

EB-332HBF-1-TP-PIC

120

0.90

EB-332HBF-2-TP-PIC

277

0.40

108

120~277 0.48~0.20

Dimen Staring
-sions Method

57

> 0.99

< 10

0.88

UL, cUL

12

AA1

IS

120

0.53

64

> 0.99

< 10

0.96

UL, cUL

12

AA1

IS

347

0.19

64

> 0.99

< 10

0.96

UL, cUL

12

AA1

IS

64

> 0.99

< 10

0.97

UL, cUL

12

AA1

IS

64

> 0.99

< 10

0.89

UL, cUL

AA1

RS

110

> 0.99

< 10

1.0

UL, cUL

13

L3

IS

74

> 0.99

< 10

0.77

UL, cUL

13

L5

IS

74

> 0.99

< 10

0.77

UL, cUL

13

L5

IS

74

> 0.99

< 10

0.77

UL, cUL

13

L5

IS

108

> 0.99

< 10

1.18

UL, cUL

13

L3

IS

> 0.99

< 10

1.18

UL, cUL

13

L3

IS

120~277 0.62~0.27

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

32W

Lamp
Type

A19

Electronic
Ballast

A20

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps
Lamp
Type

ElectronicBallasts

Lamp
Watts

32W

F32T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

100

> 0.99

< 10

1.18

UL, cUL

13

L3

IS

EB-332HBF-UV-TP-PIC 120~277 0.90~0.40

EB-332LBF-1-TP-PIC

120

0.75

88

> 0.99

< 10

0.88

UL, cUL

13

L5

IS

EB-332LBF-2-TP-PIC

277

0.32

88

> 0.99

< 10

0.88

UL, cUL

13

L5

IS

EB-332LBF-UV-TP-PIC 120~277 0.76~0.33

90

> 0.99

< 10

0.88

UL, cUL

13

L5

IS

EB-332-UV-TP-PIC

120~277 0.88~0.38

105

> 0.99

< 10

1.0

UL, cUL

13

L3

IS

EB-432EBF-1-TP-PIC

120

0.67

79

> 0.99

< 10

0.82

UL, cUL

13

L5

IS

EB-432EBF-2-TP-PIC

277

0.29

79

> 0.99

< 10

0.82

UL, cUL

13

L5

IS

EB-432EBF-UV-TP-PIC 120~277 0.67~0.29

79

> 0.99

< 10

0.82

UL, cUL

13

L5

IS

EB-432RIS-1-TPws

120

1.29

83

> 0.50

< 130

0.87

UL, cUL

13

L5

IS

EP6-132T8HO-S

120

0.87

104

> 0.99

< 10

1.2

UL, cUL

54

AA22

IS

EP6-332T8HO

347

0.30

104

> 0.99

< 15

1.18

UL, cUL

54

AA22

IS

EPQ-132T8M

120

0.73

87

> 0.99

< 10

0.94

UL, cUL

52

AA1

IS

EPQ-332T8M

347

0.25

87

> 0.99

< 10

0.95

UL, cUL

52

AA1

IS

EPQ-A32T8M

90

> 0.99

< 10/15

0.96

UL, cUL

52

AA1

IS

EPT-132T8M

120

0.69

83

> 0.99

< 10

0.96

UL, cUL

13

AA1

IS

EPT-332T8M

347

0.24

83

> 0.99

< 10

0.89

UL, cUL

13

AA1

IS

EPT-A32T8M

83

> 0.99

< 10

0.89

UL, cUL

13

AA1

IS

ESPQ-132T8HO

120

0.87

105

> 0.99

< 10

1.2

UL, cUL

57

AA29

RS

ESPQ-332T8HO

347

0.30

102

> 0.99

< 10

1.2

UL, cUL

57

AA29

RS

ESPQ-A32T8HO

107

> 0.99

< 10

1.2

UL, cUL

57

AA3

RS

EB-432EBF-1-TP-PIC

120

0.81

96

> 0.99

< 10

0.77

UL, cUL

14

L5

IS

EB-432EBF-2-TP-PIC

277

0.35

96

> 0.99

< 10

0.77

UL, cUL

14

L5

IS

EB-432LBF-1-TP-PICws ***

120

0.93

112

> 0.99

< 10

0.88

UL, cUL

14

L5

IS

EB-432LBF-2-TP-PIC ***

277

0.40

112

> 0.99

< 10

0.88

UL, cUL

14

L5

IS

EB-432RIS-1-TPws

120

1.47

EB-432LBF-UV-TP-PIC

EB-432-UV-TP-PIC

EP6-332T8HO

347

0.39

EPQ-132T8M

120

EPQ-332T8M

347

EPQ-A32T8M

ESPQ-132T8HO

ESPQ-332T8HO

ESPQ-A32T8HO

EP6-132T8HO-S

120

EP6-332T8HO

347

120~277 0.74~0.33

120~277 0.69~0.31

120~277 0.90~0.39

**

99

> 0.99

< 120

0.80

UL, cUL

14

L5

IS

120~277 0.93~0.40

112

> 0.99

< 10

0.88

UL, cUL

14

L5

IS

120~277 1.15~0.50

135

> 0.99

< 10

1.0

UL, cUL

14

L3

IS

135

> 0.99

< 15

1.25

UL, cUL

55

AA22

IS

0.88

106

> 0.99

< 10

0.87

UL, cUL

53

AA1

IS

0.30

105

> 0.99

< 10

0.87

UL, cUL

14

AA1

IS

120~277 0.88~0.39

107

> 0.99

< 10

0.87

UL, cUL

52

AA1

IS

120

1.13

136

> 0.99

< 10

1.18

UL, cUL

42

AA29

RS

347

0.40

138

> 0.99

< 10

1.18

UL, cUL

42

AA29

RS

137

> 0.99

< 10

1.18

UL, cUL

42

AA3

RS

1.73

208

> 0.99

< 10

1.2

UL, cUL

56

AA22

IS

0.60

208

> 0.99

< 10

1.18

UL, cUL

56

AA22

IS

120~277 1.14~0.50

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T8 Straight Lamps

40W

Lamp
Type

F40T8

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-142T-1-TP-SC *

120

0.57

39

> 0.50

< 130

0.88

UL, cUL

28

L8

RS

EB-232LBF-1-TP-PIC

120

0.37

43

> 0.99

< 10

1.0

UL, cUL

31

L5

IS

EB-232LBF-1-TP-PIC-SL

120

0.37

43

> 0.99

< 10

1.0

UL, cUL

31

L6

IS

EB-232LBF-2-TP-PIC

277

0.16

43

> 0.99

< 10

1.0

UL, cUL

31

L5

IS

EB-232LBF-2-TP-PIC-SL

277

0.16

43

> 0.99

< 10

1.0

UL, cUL

31

L6

IS

EB-232LBF-UV-TP-PIC 120~277 0.16~0.37

43

> 0.99

< 10

1.0

UL, cUL

31

L5

IS

EB-232RIS-1-TP-SL

120

0.60

42

> 0.57

< 150

1.0

UL, cUL

31

N3

IS

EB-232EBF-1-TP-PIC

120

0.32

38

> 0.98

< 10

0.93

UL, cUL

31

L5

IS

EB-232EBF-2-TP-PIC

277

0.14

38

> 0.98

< 10

0.93

UL, cUL

31

L5

IS

EB-232EBF-UV-TP-PIC

38

> 0.98

< 10

0.93

UL, cUL

31

L5

IS

EB-232HBF-1-TP-PIC

120

0.46

55

> 0.98

< 10

1.30

UL, cUL

31

L3

IS

EB-232HBF-2-TP-PIC

277

0.21

55

> 0.98

< 10

1.30

UL, cUL

31

L3

IS

EB-232HBF-UV-TP-PIC 120~277 0.46~0.21

55

> 0.98

< 10

1.30

UL, cUL

31

L3

IS

EPD-140T8M

120

0.37

44

> 0.99

< 10

1.03

UL, cUL

31

AA1

IS

EPD-332T8M

347

0.12

43

> 0.99

< 10

UL, cUL

31

AA1

IS

EPD-A32T8M

120~277 0.37~0.16

44

> 0.99

< 10

1.03

UL, cUL

31

AA1

IS

ESD-A32T8M

120~277 0.37~0.19

45

> 0.98

< 10/15

UL, cUL

AA1

RS

EB-332LBF-1-TP-PIC

120

0.65

77

> 0.98

< 10

0.88

UL, cUL

12

L5

IS

EB-332LBF-2-TP-PIC

277

0.28

77

> 0.98

< 10

0.88

UL, cUL

12

L5

IS

EB-332LBF-UV-TP-PIC 120~277 0.28~0.65

EB-332EBF-1-TP-PIC

EB-332EBF-2-TP-PIC

EB-332EBF-UV-TP-PIC

EB-332HBF-1-TP-PIC

120

EB-332HBF-2-TP-PIC

277

EB-332HBF-UV-TP-PIC 120~277 0.84~0.36

EPD-140T8M

EPT-332T8M

EPT-A32T8M

EB-432LBF-1-TP-PICws ***

120

EB-432LBF-2-TP-PIC

277

EB-432LBF-UV-TP-PICws

120~277 0.32~0.14

77

> 0.98

< 10

0.88

UL, cUL

12

L5

IS

120

0.56

67

> 0.98

< 10

0.88

UL, cUL

12

L5

IS

277

0.25

67

> 0.98

< 10

0.88

UL, cUL

12

L5

IS

67

> 0.98

< 10

0.88

UL, cUL

12

L5

IS

0.84

100

> 0.98

< 10

1.18

UL, cUL

12

L3

IS

0.36

100

> 0.98

< 10

1.18

UL, cUL

12

L3

IS

120~277 0.56~0.25

100

> 0.98

< 10

1.18

UL, cUL

12

L3

IS

120

0.67

80

> 0.99

< 10

0.90

UL, cUL

12

AA1

IS

347

0.22

77

> 0.99

< 15

0.89

UL, cUL

12

AA1

IS

79

> 0.99

< 10

0.89

UL, cUL

12

AA1

IS

0.40

108

> 0.98

< 10

0.88

UL, cUL

13

L5

IS

0.90

108

> 0.98

< 10

0.88

UL, cUL

13

L5

IS

108

> 0.98

< 10

0.88

UL, cUL

13

L5

IS

120~277 0.65~0.29

120~277 0.40~0.90

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A21

Electronic
Ballast

ElectronicBallasts

A22

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T8 Straight Lamps

Lamp
Watts

40W

Lamp
Type

F40T8

No. of
Lamps

Cat.
Number

Input
Volts

EB-432EBF-1-TP-PIC

EB-432EBF-2-TP-PIC

3
3

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

120

0.82

98

> 0.98

< 10

0.85

UL, cUL

13

L5

IS

277

0.36

98

> 0.98

< 10

0.85

UL, cUL

13

L5

IS

EB-432EBF-UV-TP-PIC 120~277 0.82~0.36

98

> 0.98

< 10

0.85

UL, cUL

13

L5

IS

EPQ-140T8M

120

0.89

107

> 0.99

< 10

0.87

UL, cUL

52

AA1

IS

EPQ-332T8M

347

0.31

107

> 0.99

< 10

0.87

UL, cUL

52

AA1

IS

EPQ-A32T8M

108

> 0.99

< 10/15

0.89

UL, cUL

52

AA1

IS

ESPQ-132T8HO

120

1.02

122

> 0.99

< 10

1.02

UL, cUL

57

A29

RS

ESPQ-332T8HO

347

0.36

125

> 0.99

< 10

0.90

UL, cUL

57

A29

RS

ESPQ-132T8HO

120

1.36

163

> 0.99

< 10

0.72

UL, cUL

42

A29

RS

ESPQ-332T8HO

347

0.48

166

> 0.99

< 10

0.74

UL, cUL

42

AA29

RS

1 OR 2 EB-259-1-TP-PIC **

120

0.95

112

> 0.99

< 10

0.88

UL, cUL

12

L3

IS

1 OR 2 EB-259-2-TP-PIC **

277

0.41

112

> 0.98

< 10

0.88

UL, cUL

12

L3

IS

120~277 0.89~0.40

112

> 0.98

< 10

0.88

UL, cUL

12

L3

IS

120

0.55

66

> 0.99

< 10

1.07

UL, cUL

31

AA1

IS

347

0.19

66

> 0.99

< 10

1.05

UL, cUL

31

AA1

IS

67

> 0.99

< 10

1.09

UL, cUL

31

AA1

IS

0.89

107

> 0.99

< 10

0.89

UL, cUL

12

AA1

IS

0.32

110

> 0.99

< 10

0.92

UL, cUL

12

AA1

IS

120~277 0.89~0.39

107

> 0.99

< 10

0.89

UL, cUL

12

AA1

IS

120~277

0.92~0.4

110

> 0.99

< 10

1.12

UL, cUL

AA22

RS

347

0.19

66

> 0.99

< 10

1.05

UL, cUL

31

AA1

IS

67

> 0.99

< 10

1.09

UL, cUL

31

AA1

IS

110

> 0.99

< 10

UL, cUL

AA29

RS

110

> 0.99

< 10

0.92

UL, cUL

12

AA1

IS

107

> 0.99

< 10

0.89

UL, cUL

12

AA1

IS

1 OR 2 EB-259-UV-TP-PIC ** 120~277 0.95~0.41

59W

86W

F96T8

F96T8

Dimen Staring
-sions Method

EPD-159T8M

EPD-359T8M

EPD-A59T8M

EPD-159T8M

120

EPD-359T8M

347

EPD-A59T8M

ESD-A86T8HO

EPD-359T8M

EPD-A59T8M

120~277 0.55~0.25

ESD-A86T8HO

120~277 1.56~0.67

ESD-A86T8HO

EPD-A59T8M

120~277 0.55~0.25

347

0.32

120~277 0.89~0.39

* replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS
T12 Straight Lamps
Lamp
Watts

Lamp
Type

No. of
Lamps

14W

F14T12

1
1

20W

25W

30W

34W

34W

40W

40W

F15T12

F20T12

F40T12

F30T12

F40T12
Energy
Saver

F40T12
/U
Energy
Saver

F40T12

F40T12
/U

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

EB-120-1-TP
EB-120-1-TP-EMI

120
120

0.24
0.24

> 0.50

< 150
< 150

1.0

X1

RS

1.0

UL, cUL
UL, cUL

28

> 0.50

28

L7

RS

EB-220-1-TP #

120

0.42

> 0.50

< 150

0.85

UL, cUL

30

L7

RS

EB-120-1-TP

120

0.26

> 0.50

< 150

1.0

UL, cUL

28

X1

RS

EB-120-1-TP-EMI

120

0.26

> 0.50

< 150

1.02

UL, cUL

28

L7

RS

EB-220-1-TP #

120

0.45

> 0.50

< 150

1.02

UL, cUL

30

L7

RS

EB-120-1-TP

120

0.27

> 0.50

< 150

0.90

UL, cUL

28

X1

RS

EB-120-1-TP-EMI

120

0.27

> 0.50

< 150

0.90

UL, cUL

28

L7

RS

EB-220-1-TP #

120

0.52

> 0.50

< 150

0.87

UL, cUL

30

L7

RS

EB-1382D-1-TP

120

0.60

> 0.50

< 150

0.95

UL, cUL

28

S1

RS

EB-1382D-1-TP-LC

120

0.60

15
15
27
17
17
32
18
18
36
40
40

> 0.50

< 150

0.95

UL, cUL

28

L2

RS

EB-140-1-TP #

120

0.53

36

> 0.50

< 150

0.88

UL, cUL

28

L7

RS

EB-240-UV-TP-PIC

51

> 0.99

< 10

1.70

UL, cUL

39

L5

RS

EB-240-1-TP

120

0.85

56

> 0.50

< 150

1.05

UL, cUL

30

L1

RS

EB-240-1-TP-PIC

120

0.66

78

> 0.99

< 10

1.40

UL, cUL

L5

RS

EB-240-UV-TP-PIC

EB-240-1-TP

120~277 0.43~0.19

120~277 0.66~0.28

Dimen Staring
-sions Method

78

> 0.99

< 10

1.40

UL, cUL

L5

RS

120

0.73

47

0.55

< 150

0.85

UL, cUL

30

L1

RS

EB-240-1-TP-PIC

120~277

0.32

38

> 0.98

< 10

1.00

UL, cUL

39

L5

RS

EB-240-UV-TP-PIC

120~277 0.32~0.14

38

> 0.99

< 10

1.00

UL, cUL

L5

RS

EB-240-1-TP-PIC

58

> 0.99

< 10

0.88

UL, cUL

L5

RS

EB-240-UV-TP-PIC

58

> 0.99

< 10

0.88

UL, cUL

L5

RS

EB-1382D-1-TP

120

0.59

39

> 0.50

< 150

1.00

UL, cUL

28

S1

RS

EB-1382D-1-TP-LC

120

0.59

39

> 0.50

< 150

1.00

UL, cUL

28

L2

RS

EB-140-1-TP #

120

0.45

30

> 0.50

< 150

0.88

UL, cUL

28

L7

RS

EB-240-UV-TP-PIC

40

> 0.98

< 10

1.10

UL, cUL

39

L5

RS

EB-240-1-TP

120

0.76

48

> 0.50

< 150

0.73

UL, cUL

30

L1

RS

EB-240-1-TP-PIC

120

0.53

63

> 0.99

< 10

0.85

UL, cUL

L5

RS

EB-240-UV-TP-PIC

63

> 0.98

< 10

0.85

UL, cUL

L5

RS

EB-140-1-TP #

30

> 0.50

< 150

0.88

UL, cUL

28

L7

RS

EB-240-UV-TP-PIC

40

> 0.98

< 10

1.10

UL, cUL

39

L5

RS

EB-240-1-TP-PIC

63

> 0.98

< 10

0.85

UL, cUL

L5

RS

EB-240-UV-TP-PIC

63

> 0.98

< 10

0.85

UL, cUL

L5

RS

EB-1382D-1-TP

120

0.60

40

> 0.50

< 150

0.95

UL, cUL

28

S!

RS

EB-1382D-1-TP-LC

120

0.60

40

> 0.50

< 150

0.95

UL, cUL

28

L2

RS

EB-140-1-TP #

120

0.53

36

> 0.50

< 150

0.88

UL, cUL

28

L7

RS

EB-240-UV-TP-PIC

47

> 0.99

< 10

1.10

UL, cUL

L5

RS

EB-240-1-TP

120

0.87

58

> 0.50

< 150

0.75

UL, cUL

30

L1

RS

EB-240-1-TP-PIC

120

0.62

74

> 0.99

< 10

0.88

UL, cUL

L5

RS

EB-240-UV-TP-PIC

74

> 0.99

< 10

0.88

UL, cUL

L5

RS

EB-140-1-TP #

36

> 0.50

< 150

0.88

UL, cUL

28

L7

RS

EB-240-UV-TP-PIC

47

> 0.99

< 10

1.10

UL, cUL

39

L5

RS

EB-240-1-TP-PIC

74

> 0.99

< 10

0.88

UL, cUL

L5

RS

EB-240-UV-TP-PIC

74

> 0.99

< 10

0.88

UL, cUL

L5

RS

120

0.49

120~277 0.49~0.22

120~277 0.34~0.15

120~277 0.53~0.23
120

0.45

120~277 0.34~0.15
120

0.53

120~277 0.53~0.23

120~277 0.40~0.17

120~277 0.62~0.27
120

0.53

120~277 0.40~0.17
120

0.62

120~277 0.62~0.27

# add EMI for model with EMI filter, comply with FCC Class B.

ws This item is well stocked

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

15W

A23

Electronic
Ballast

ElectronicBallasts

A24

ELECTRONIC BALLAST FOR


FLUORESCENT LAMPS

T12 Straight Lamps

Lamp
Watts

Lamp
Type

30W

F48T12/
ES

35W

40W

57W

60W

75W

F42T12

F48T12

F72T12

F96T12/
ES

F96T12

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

120
277

0.60
0.26

64
64

0.98

< 12
< 12

0.92

UL, cUL
UL, cUL

12

D8

IS

12

D8

IS

0.92

12

D8

IS

12

L5

IS

1.00

UL, cUL
UL, cUL
UL, cUL

12

L5

IS

2
2

EB-275-1-TP-PIC*
EB-275-2-TP-PIC*

2
2
2

EB-275-UV-TP-PIC*
EB-260-1-TP-PIC
EB-260-2-TP-PIC

120~277 0.60~0.26
120
0.55
277
0.24

64
66
66

0.95
0.98

< 12
< 12
< 12

EB-260-UV-TP-PIC

120~277 0.55~0.24

66

0.95

< 12

1.00

UL, cUL

12

L5

IS

EB-260-1-TP-PIC

120

0.62

74

0.98

< 12

0.92

UL, cUL

12

L5

IS

EB-275-1-TP-PIC*

120

0.68

76

0.98

< 12

0.92

UL, cUL

12

D8

IS

EB-260-2-TP-PIC

277

0.27

74

0.98

< 12

0.92

UL, cUL

12

L5

IS

EB-275-2-TP-PIC*

277

0.30

76

0.95

< 12

0.92

UL, cUL

12

D8

IS

EB-260-UV-TP-PIC

120~277 0.62~0.27

74

0.95

< 12

0.92

UL, cUL

12

L5

IS

EB-275-UV-TP-PIC*

120~277 0.68~0.30

76

0.95

< 12

0.92

UL, cUL

12

D8

IS

EB-275-1-TP-PIC*

EB-275-2-TP-PIC*

EB-275-UV-TP-PIC*

EB-260-1-TP-PIC

120

EB-275-1-TP-PIC*

120

EB-260-2-TP-PIC

EB-275-2-TP-PIC*

EB-260-UV-TP-PIC

EB-275-UV-TP-PIC*

EB-275-1-TP-PIC*

120

0.60

EB-275-2-TP-PIC*

277

0.27

EB-275-UV-TP-PIC*

EB-260-1-TP-PIC

120

0.97

EB-275-1-TP-PIC*

120

0.97

EB-260-2-TP-PIC

277

0.42

EB-275-2-TP-PIC

277

0.42

EB-260-UV-TP-PIC

120~277 0.97~0.42

EB-275-UV-TP-PIC*

120~277 0.97~0.42

EB-275-1-TP-PIC*

EB-275-2-TP-PIC*

EB-275-UV-TP-PIC*

EB-275-1-TP-PIC*

120

EB-275-2-TP-PIC*

277

EB-275-UV-TP-PIC*

0.95
0.98

0.92
1.00

120

0.60

67

0.98

< 12

1.05

UL, cUL

31

D8

IS

277

0.26

67

0.95

< 12

1.05

UL, cUL

31

D8

IS

67

0.95

< 12

1.05

UL, cUL

31

D8

IS

0.90

106

0.98

< 12

0.95

UL, cUL

12

L5

IS

0.92

107

0.98

< 12

0.95

UL, cUL

12

D8

IS

277

0.39

106

0.98

< 12

0.95

UL, cUL

12

L5

IS

277

0.40

107

0.95

< 12

0.95

UL, cUL

12

D8

IS

120~277 0.92~0.39

106

0.95

< 12

0.95

UL, cUL

12

L5

IS

120~277 0.92~0.40

107

0.95

< 12

0.95

UL, cUL

12

D8

IS

71

> 0.98

< 12

1.12

UL, cUL

31

D8

IS

72

> 0.98

< 12

1.12

UL, cUL

31

D8

IS

72

> 0.98

< 12

1.12

UL, cUL

31

D8

IS

115

> 0.98

< 12

0.95

UL, cUL

12

L5

IS

115

> 0.98

< 12

0.95

UL, cUL

12

D8

IS

115

> 0.98

< 12

0.95

UL, cUL

12

L5

IS

115

> 0.98

< 12

0.95

UL, cUL

12

D8

IS

115

0.95

< 12

0.95

UL, cUL

12

L5

IS

115

> 0.98

< 12

0.95

UL, cUL

12

D8

IS

< 12

1.05

UL, cUL

31

D8

IS

120~277 0.60~0.26

120~277 0.27~0.60

120

0.69

83

> 0.98

277

0.31

83

> 0.98

< 12

1.05

UL, cUL

31

D8

IS

83

> 0.98

< 12

1.05

UL, cUL

31

D8

IS

1.15

133

> 0.98

< 12

0.86

UL, cUL

12

D8

IS

0.50

136

> 0.98

< 12

0.86

UL, cUL

12

D8

IS

133

> 0.98

< 12

0.86

UL, cUL

12

D8

IS

120~277 031~0.69

120~277 0.49~1.15

* add SL for model L3 or AA1 Case style.


ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


HIGHOUTPUT LAMPS
T12 Straight Lamps

60W

75W

85W

95W

Lamp
Type

No. of
Lamps

F48T12/HO

F60T12/HO

F72T12/HO

F96T12/HO/
ES

110W F96T12/HO

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-2110-1-TP-PIC

120

0.88

104

> 0.98

< 10

0.90

UL, cUL

AA1

RS

EB-2110-2-TP-PIC

277

0.38

104

> 0.98

< 10

0.90

UL, cUL

AA1

RS

EB-2110-UV-TP-PIC

104

> 0.95

< 20

0.90

UL, cUL

AA1

RS

EB-2110-1-TP-PIC

120

1.10

132

> 0.98

< 10

0.90

UL, cUL

AA1

RS

EB-2110-2-TP-PIC

277

0.48

132

> 0.98

< 10

0.90

UL, cUL

AA1

RS

EB-2110-UV-TP-PIC

132

> 0.95

< 20

0.90

UL, cUL

AA1

RS

EB-2110-1-TP-PIC

EB-2110-2-TP-PIC

EB-2110-UV-TP-PIC

EB-2110-1-TP-PIC

EB-2110-2-TP-PIC

EB-2110-UV-TP-PIC

EB-260-1-TP-PIC

EB-260-2-TP-PIC

EB-260-UV-TP-PIC

EB-2110-1-TP-PIC

120

EB-2110-2-TP-PIC

277

EB-2110-UV-TP-PIC

EB-2110-1-TP-PIC

EB-2110-2-TP-PIC

EB-2110-UV-TP-PIC

120~277 0.88~0.38

120~277 1.10~0.48
120

1.30

154

> 0.98

< 10

0.90

UL, cUL

AA1

RS

277

0.56

154

> 0.98

< 10

0.90

UL, cUL

AA1

RS

154

> 0.95

< 10

0.90

UL, cUL

AA1

RS

120~277 1.30~0.56
120

1.38

164

> 0.98

< 10

0.90

UL, cUL

AA1

RS

277

0.60

164

> 0.98

< 10

0.90

UL, cUL

AA1

RS

164

> 0.95

< 20

0.90

UL, cUL

AA1

RS

108

> 0.98

< 12

1.00

UL, cUL

31

L5

IS

120~277 1.38~0.60
120

0.90

277

0.39

106

> 0.98

< 12

1.00

UL, cUL

31

L5

IS

108

> 0.95

< 20

1.00

UL, cUL

31

L5

IS

0.88

104

> 0.98

< 10

0.92

UL, cUL

39

AA1

RS

0.38

104

> 0.98

< 10

0.92

UL, cUL

39

AA1

RS

120~277 0.90~0.39

104

> 0.95

< 20

0.92

UL, cUL

39

AA1

RS

120

1.65

196

> 0.98

< 10

0.90

UL, cUL

AA1

RS

277

0.72

196

> 0.98

< 10

0.90

UL, cUL

AA1

RS

196

> 0.95

< 20

0.90

UL, cUL

AA1

RS

120~277 0.88~0.38

120~277 1.65~0.72

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A25

Electronic
Ballast

T5 Compact Lamps
Lamp
Watts

Lamp
Type

No. of
Lamps

7W

CFT7W/2G7

9W

CFT9W/2G7

ElectronicBallasts

A26

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS

13W

13W

13W

CFQ13W/
G24q

CFTR13
W/
GX24q

CFT13W/
2GX7

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

EB-108-1-TP-FC

120

0.12

7.5

> 0.50

< 150

1.05

UL, cUL

26

EB-108-1-TP-FC

120

0.13

< 150

1.0

UL, cUL

EB-113-1-TP
EB-113-1-TP-MC

120
120

0.22
0.22

8.5
14
14

> 0.50

1
1

> 0.50

0.90

> 0.50

< 150
< 150

0.90

UL, cUL
UL, cUL

EB-113-1-TP-SL

120

0.22

14

> 0.50

< 150

0.90

EB-113-1-TP-SL-MC

120

0.22

14

> 0.50

< 150

0.90

EB-113-1-TP-SLLws

120

0.22

14

> 0.50

< 150

EB-113-1-TP-SLL-MCws

120

0.22

14

> 0.50

EB-113-1-TP-PN

120

0.22

14

> 0.50

EB-113-1-TP-SC #

120

0.22

14

EB-114-1-TP-FC

120

0.22

EB-213-UV-TP-PIC-DWws*

EB-213-UV-TP-PSD* 120~277

CSD-UV-18Pws

CSD-UV-18PBM

120~277 0.29~0.14

EB-213-1-TP

120

EB-213-1-TP-MCws

120

EB-213-1-TP-SLws

EB-213-1-TP-SL-MCws

2
2

EB-213-UV-TP-PIC-DWws*

2
2

EB-213-1-TP-SC #

120

EB-213-1-TP-DW *

120

CSD-UV-18Pws

Dimen Staring
-sions Method
V1

RS

26

V1

RS

26

C6

RS

26

J1

RS

UL, cUL

26

N2

RS

UL, cUL

26

P2

RS

0.90

UL, cUL

26

N1

RS

< 150

0.90

UL, cUL

26

P1

RS

< 150

0.90

UL, cUL

26

S1

RS

> 0.50

< 150

0.90

UL, cUL

26

L8

RS

14

> 0.50

< 150

0.90

UL, cUL

26

V1

RS

18

> 0.96

< 10

1.1

UL, cUL

35

W1

RS

0.14~0.065

17

> 0.95

< 12

1.05

UL, cUL

35

W1

PS

120~277 0.29~0.13

35

> 0.98

< 10/15

1.3

UL, cUL

33

AA15

PS

35

> 0.98

< 10/15

1.3

UL, cUL

33

AA16

PS

0.43

28

> 0.50

< 150

0.95

UL, cUL

29

C6

RS

0.43

28

> 0.50

< 150

0.95

UL, cUL

29

J1

RS

120

0.43

28

> 0.50

< 150

0.95

UL, cUL

29

N1

RS

120

0.43

28

> 0.50

< 150

0.95

UL, cUL

29

P1

RS

EB-213-UV-TP-PSD* 120~277 0.26~0.12

30

> 0.98

< 10

1.0

UL, cUL

33

W1

PS

0.27~0.12

32

> 0.99

< 10

1.05

UL, cUL

33

W1

RS

EB-213-UV-TP-PICws * 120~277 0.27~0.12

32

> 0.99

< 10

1.05

UL, cUL

33

T1

RS

0.43

28

> 0.50

< 150

0.95

UL, cUL

29

L8

RS

0.43

28

> 0.50

< 150

0.95

UL, cUL

33

W1

RS

120~277 0.18~0.07

19

> 0.96

< 17

1.47

UL, cUL

35

AA15

PS

CSD-UV18PBMws

120~277 0.18~0.07

19

> 0.96

< 17

1.47

UL, cUL

35

AA16

PS

FSD-A18PBM

120~277 0.14~0.07

18

> 0.97

< 10/20

0.95

UL, cUL

35

AA23

PS

GSD-A18PBM

120~277 0.14~0.07

EB-213-UV-TP-PSD* 120~277

1
2

120~277 0.15~0.07

120~277

18

> 0.98

< 10/20

0.95

UL, cUL

35

AA24

PS

0.14~0.065

17

> 0.95

< 12

1.05

UL, cUL

35

W1

PS

EB-213-UV-TP-PIC-DWws *

120~277 0.15~0.07

18

> 0.96

< 10

1.1

UL, cUL

35

W1

RS

CSD-B18P

277~347 0.13~0.1

35

> 0.99

< 15

1.31

UL, cUL

33

AA15

PS

CSD-UV-18Pws

120~277 0.28~0.13

35

> 0.98

< 10/15

1.3

UL, cUL

33

AA15

PS

CSD-UV18PBMws

120~277 0.28~0.13

35

> 0.98

< 10/15

1.3

UL, cUL

33

AA16

PS

EB-213-UV-TP-PIC-DWws *

120~277 0.27~0.07

32

> 0.99

< 10

1.05

UL, cUL

33

W1

RS

FSD-A18PBMws

120~277 0.27~0.12

33

> 0.98

< 10

0.91

UL, cUL

33

AA23

PS

GSD-A18PBMws

120~277 0.27~0.12

33

> 0.98

< 10

0.98

UL, cUL

33

AA24

PS

EB-213-UV-TP-PIC-DW * 120~277 0.27~0.12

32

> 0.99

< 10

1.05

UL, cUL

33

W1

RS

EB-213-1-TP-SC #

120

0.43

28

> 0.50

< 150

0.95

UL, cUL

29

L8

RS

EB-213-1-TP-DW *

120

0.43

28

> 0.50

< 150

0.95

UL, cUL

33

W1

RS

EB-113FT-1-TP-PN

120

0.20

13

> 0.50

< 150

0.95

UL, cUL

26

S1

RS

EB-113FT-1-TP-SC #

120

0.20

13

> 0.50

< 150

0.95

UL, cUL

26

L8

RS

* Ballast with bottom out connectors and with studs, Add /NS for case with bottom out connectors and without studs, Add /LS for
case with lead wire out and with studs, Add /NL for case with lead wire out and without studs

ws This item is well stocked

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS
T5 Compact Lamps

18W

18W

18W

Lamp
Type

CFQ18
W/G24q

CFTR18
W/
GX24q

CFTR18
W/
GX24q

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EB-1C22-1-TP

120

0.33

20

> 0.50

< 150

1.0

UL, cUL

26

S1

RS

EB-1C22-1-TP-LC

120

0.33

20

> 0.50

< 150

1.0

UL, cUL

26

L1

RS

EB-1C22-1-TP-SC #

120

0.33

20

> 0.50

< 150

1.0

UL, cUL

26

L8

RS

EB-118-1-TP-SC #

120

0.28

18

> 0.50

< 150

1.0

UL, cUL

26

L8

RS

EB-213-UV-TP-PICws * 120~277 0.21~0.0085

23

> 0.98

< 12

1.2

UL, cUL

35

T1

RS

EB-218-UV-TP-PIC-DWws*

120~277 0.21~0.10

24

> 0.95

< 12

1.2

UL, cUL

35

W1

RS

EB-218-UV-TP-PICws*

120~277 0.36~0.16

40

> 0.99

< 10

1.1

UL, cUL

33

T1

RS

EB-218-UV-TP-PIC-DWws*

120~277 0.36~0.16

40

> 0.99

< 10

1.1

UL, cUL

33

W1

RS

EB-218-1-TP

120

0.59

36

> 0.50

< 150

1.0

UL, cUL

29

C6

RS

EB-218-1-TP-SC #

120

0.59

36

> 0.50

< 150

1.0

UL, cUL

29

L8

RS

EB-218-1-TP-DW *

120

0.59

36

> 0.50

< 150

1.0

UL, cUL

33

W1

RS

EB-218-UV-TP-PIC-DWws

120~277 0.21~0.10

24

> 0.95

< 12

1.2

UL, cUL

35

W1

RS

EB-218-UV-TP-PIC-DWws

120~277 0.36~0.16

42

> 0.99

< 10

1.1

UL, cUL

33

W1

RS

EB-218-1-TP-SC #

120

0.59

36

> 0.50

< 150

1.0

UL, cUL

29

L8

RS

EB-218-1-TP-DW *

120

0.59

36

> 0.50

< 150

1.0

UL, cUL

33

W1

RS

CSD-B18P

277~347 0.08~0.06

22

> 0.98

< 15

1.1

UL, cUL

35

AA15

PS

CSD-UV-18P

120~277 0.18~0.08

22

> 0.98

< 15

1.27

UL, cUL

35

AA15

PS

CSD-UV-18PBM

120~277 0.17~0.08

22

> 0.98

< 15

1.1

UL, cUL

35

AA16

PS

EB-218-UV-TP-PSD*

120~277 0.17~0.08

20

> 0.95

< 12

1.0

UL, cUL

35

W1

PS

FSD-A18PBMws

120~277 0.17~0.08

21

> 0.97

< 10/15

0.92

UL, cUL

35

AA23

PS

GSD-A18PBM

120~277 0.17~0.08

21

> 0.98

< 10/15

0.92

UL, cUL

35

AA24

PS

CSD-UV-18Pws

120~277 0.34~0.15

41

> 0.99

< 10/15

1.08

UL, cUL

33

AA15

PS

CSD-B18P

120~277 0.14~0.11

40

> 0.99

< 10

1.1

UL, cUL

33

AA15

PS

CSD-UV18PBM

120~277 0.34~0.15

41

> 0.98

< 10/15

1.13

UL, cUL

33

AA16

PS

EB-218-UV-TP-PSD*

120~277 0.30~0.13

36

> 0.98

< 10

0.95

UL, cUL

33

W1

PS

FSD-A18PBMws

120~277 0.32~0.15

39

> 0.98

< 10/15

0.85

UL, cUL

33

AA23

PS

GSD-A18PBMws

120~277 0.32~0.15

39

> 0.98

< 10/15

0.92

UL, cUL

33

AA24

PS

* Ballast with bottom out connectors and with studs, Add /NS for case with bottom out connectors and without studs, Add /LS for case with lead wire out and with
studs, Add /NL for case with lead wire out and without studs.
# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A27

Electronic
Ballast

ElectronicBallasts

A28

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS

T5 Compact Lamps

Lamp
Watts

26W

Lamp
Type

CFQ26
W/G24q

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

CSD-UV32P/BM

120-277 0.29-0.13

36

> 0.95

< 10/40

UL, cUL

35

AA18

PS

CSD-UV32PXS

120-277 0.29-0.13

36

> 0.95

< 10/40

UL, cUL

35

AA5

PS

CSD-UV42P

120-277

0.3-0.13

36

> 0.98

< 20/50

0.99

UL, cUL

35

AA19

PS

CSD-UV42P/BM

120-277 0.24-0.13

30

> 0.97

< 30/60

UL, cUL

35

AA21

PS

EB-126-1-TP

120

0.40

24

> 0.50

< 150

0.90

UL, cUL

26

S1

RS

EB-126-1-TP-SC #

120

0.40

24

> 0.50

< 150

0.90

UL, cUL

26

L8

RS

EB-142T-1-TP-SC #

120

0.43

28

> 0.50

< 150

1.05

UL, cUL

26

L8

RS

EB-218-UV-TP-PICws * 120-277 0.26~0.11

30

> 0.98

< 10

1.05

UL, cUL

35

T1

RS

EB-226-UV-TP-PIC-DWws*

120-277 0.27~0.12

33

> 0.96

< 12

1.2

UL, cUL

35

W1

RS

EB-226-UV-TP-PSD*

120-277 0.23~0.10

27

> 0.95

< 10

0.95

UL, cUL

35

W1

PS

EB-242T-UV-TP-PSD*

120-277 0.27~0.13

32

> 0.95

< 10

1.0

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW *

120-277 0.27~0.13

32

> 0.95

< 10

1.0

UL, cUL

35

W2

RS

FSD-A32PBMws

120-277 0.19-0.09

23

> 0.98

< 10/15

0.74

UL, cUL

35

AA23

PS

GSD-A18PBMws

120-277 0.19-0.09

23

> 0.98

< 10/15

0.74

UL, cUL

35

AA24

PS

CSD-B42PBM

277-347 0.22-0.18

60

> 0.98

< 15

UL, cUL

33

AA20

PS

CSD-B42PS

277-347 0.32-0.18

60

> 0.98

< 10/15

0.90

UL, cUL

33

AA19

CSD-UV32P/BM

120-277 0.49-0.21

59

> 0.99

< 10

UL, cUL

33

AA18

PS

CSD-UV32PXS

120-277 0.49-0.21

59

> 0.99

< 10

UL, cUL

33

AA15

PS

CSD-UV42P

120-277 0.46-0.21

56

> 0.98

< 10/20

1.07

UL, cUL

33

AA19

PS

CSD-UV42PBM

120-277 0.46~0.21

56

> 0.98

< 10/20

1.07

UL, cUL

33

AA20

PS

EB-226-1-TPws

120

0.80

51

> 0.50

< 150

1.0

UL, cUL

29

C6

RS

EB-226-1-TP-SC #

120

0.80

51

> 0.50

< 150

1.0

UL, cUL

29

L8

RS

EB-226-1-TP-DW *

120

0.80

51

> 0.50

< 150

1.0

UL, cUL

33

W1

RS

EB-226-UV-TP-PSD*

120-277 0.42~0.18

51

> 0.98

< 10

0.95

UL, cUL

33

W1

PS

EB-226-UV-TP-PIC *

120-277 0.49~0.21

58

> 0.99

< 10

1.0

UL, cUL

33

T1

RS

EB-226-UV-TP-PIC-DWws*

120-277 0.49~0.21

58

> 0.99

< 10

1.0

UL, cUL

33

W1

RS

EB-240-1-TP

43

> 0.50

< 150

0.85

UL, cUL

29

L1

RS

EB-242T-UV-TP-PICws*

60

> 0.97

< 10

1.05

UL, cUL

33

T2

RS

120

0.69

120-277 0.50~0.22

* Ballast with bottom out connectors and with studs, Add /NS for case with bottom out connectors and without studs, Add /LS for case with lead wire out and with
studs, Add /NL for case with lead wire out and without studs.
# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS
T5 Compact Lamps

26W

26W

Lamp
Type

CFQ26W/
G24q

CFTR26
W/G24Xq

CFTR32
32W
W/GX24q

No. of
Lamps

Cat.
Number

EB-242T-UV-TP-PIC-DWws*

2
2

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

120~277 0.45~0.21

54

> 0.97

< 10

0.90

UL, cUL

33

EB-242T-UV-TP-PSD*

120~277 0.45~0.21

54

> 0.97

< 10

0.90

UL, cUL

FSD-A32PBMws

120~277 0.5-0.22

59

> 0.98

< 10/20

0.93

UL, cUL

GSD-A32PBM

120~277 0.5-0.22

59

> 0.98

< 10/20

0.93

EB-142T-1-TP-SC #

26

> 0.50

< 50

EB-226-UV-TP-PSD*

120~277 0.20~0.09

24

> 0.95

< 10

EB-226-UV-TP-PIC-DWws*

120~277 0.26~0.11

30

> 0.96

< 12

EB-242T-UV-TP-PIC-DW *

120~277 0.27~0.13

32

> 0.95

EB-242T-UV-TP-PSD*

120~277 0.27~0.13

32

> 0.95

EB-226-UV-TP-PIC-DWws*

120~277 0.46~0.20

54

> 0.98

EB-242T-UV-TP-PICws *

120~277 0.48~0.21

56

EB-226-1-TP-SC #

120

0.80

51

EB-226-1-TP-DW *

120

0.80

EB-226-UV-TP-PSD*

EB-242T-UV-TP-PIC-DW *

2
1

Dimen Staring
-sions Method
W2

RS

33

W2

PS

33

AA23

PS

UL, cUL

35

AA24

PS

1.0

UL, cUL

26

L8

RS

0.90

UL, cUL

35

W1

PS

1.05

UL, cUL

35

W1

RS

< 10

1.0

UL, cUL

35

W2

RS

< 10

1.0

UL, cUL

35

W2

PS

< 10

0.95

UL, cUL

33

W1

RS

> 0.97

< 10

1.0

UL, cUL

33

T2

RS

> 0.50

< 150

1.0

UL, cUL

29

L8

RS

51

> 0.50

< 150

1.0

UL, cUL

33

W1

RS

120~277 0.40~0.18

48

> 0.98

< 10

0.90

UL, cUL

33

W1

PS

120~277 0.45~0.21

54

> 0.97

< 10

0.90

UL, cUL

33

W2

RS

EB-242T-UV-TP-PSD*

120~277 0.45~0.21

54

> 0.97

< 10

0.90

UL, cUL

33

W2

PS

CSD-UV32P/BM

120~277 0.33~0.15

36

> 0.98

< 10/20

0.94

UL, cUL

35

AA18

PS

CSD-UV32PXS

120~277 0.33~0.15

36

> 0.98

< 10/20

0.93

UL, cUL

35

AA15

PS

CSD-UV42P

120~277 0.30~0.13

35

> 0.98

< 20/50

0.99

UL, cUL

35

AA19

PS

CSD-UV42P/BM

120~277 0.30~0.13

35

> 0.98

< 20/25

0.88

UL, cUL

35

AA21

PS

CSD-UV42PBM

120~277 0.30~0.13

35

> 0.98

< 20/50

0.99

UL, cUL

35

AA20

PS

EB-142T-1-TP-SC#

33

> 0.50

< 130

0.95

UL, cUL

26

L8

RS

EB-226-UV-TP-PICws*

120~277 0.35~0.15

41

> 0.98

< 10

1.1

UL, cUL

35

T1

RS

EB-226-UV-TP-PIC-DWws*

120~277 0.35~0.15

41

> 0.98

< 10

1.1

UL, cUL

35

W1

RS

EB-226-UV-TP-PSD*

120~277 0.30~0.13

36

> 0.98

< 10

1.0

UL, cUL

35

W1

PS

EB-242T-UV-TP-PIC-DW*

120~277 0.35~0.13

42

> 0.96

< 10

0.96

UL, cUL

35

W2

RS

EB-242T-UV-TP-PSD*

120~277 0.35~0.13

42

> 0.96

< 10

0.96

UL, cUL

35

W2

PS

EB-240-1-TP

61

> 0.50

< 150

0.89

UL, cUL

30

L1

RS

EB-232T-UV-TP-PIC*

120~277 0.55~0.24

65

> 0.98

< 10

0.95

UL, cUL

33

T2

RS

EB-242T-UV-TP-PICws*

120~277 0.62~0.27

74

> 0.97

< 10

1.0

UL, cUL

33

T2

RS

EB-242T-UV-TP-PIC-DW*

120~277 0.56~0.23

69

> 0.96

< 10

0.90

UL, cUL

33

W2

RS

120

120

120

0.40

0.50

0.91

* Ballast with bottom out connectors and with studs, Add /NS for case with bottom out connectors and without studs, Add /LS for case with lead wire out and with
studs, Add /NL for case with lead wire out and without studs.
# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A29

Electronic
Ballast

ElectronicBallasts

A30

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS

T5 Compact Lamps

Lamp
Watts

Lamp
Type

32W

CFTR32
W/GX24q

42W

CFTR42
W/GX24q

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

FSD-A32PBMws

120~277 0.29~0.13

34

> 0.97

< 10/30

0.88

UL, cUL

35

AA23

PS

FSD-B32PBMws

277~347 0.13~0.11

35

> 0.98

< 15

0.88

UL, cUL

35

AA23

PS

GSD-A32PBM

120~277 0.29~0.13

34

> 0.97

< 10/30

0.88

UL, cUL

35

AA24

PS

CSD-UV32P/BM

120~277 0.37~0.17

46

> 0.99

< 10/15

0.89

UL, cUL

35

AA18

PS

CSD-UV32PXS

120~277 0.37~0.17

46

> 0.99

< 10/15

0.89

UL, cUL

35

AA15

PS

CSD-UV42P

120~277 0.38~0.18

46

> 0.98

< 15/30

0.99

UL, cUL

35

AA19

PS

CSD-UV42P/BM

120~277 0.38~0.18

46

> 0.98

< 15/30

0.99

UL, cUL

35

AA21

PS

CSD-UV42PBM

120~277 0.36~0.17

43

> 0.98

< 20/35

0.91

UL, cUL

35

AA20

PS

EB-142T-1-TP-SC #

37

> 0.50

< 120

0.80

UL, cUL

26

L8

RS

EB-226-UV-TP-PSD*

120~277 0.38~0.16

45

> 0.98

< 10

1.0

UL, cUL

35

W1

PS

EB-226-UV-TP-PICws *

120~277 0.45~0.19

53

> 0.98

< 10

1.1

UL, cUL

35

T1

RS

EB-226-UV-TP-PIC-DWws*

120~277 0.45~0.19

53

> 0.98

< 10

1.1

UL, cUL

35

W1

RS

EB-242T-UV-TP-PIC-DW*

120~277 0.38~0.18

47

> 0.96

< 10

0.96

UL, cUL

35

W2

RS

EB-242T-UV-TP-PSD*

120~277 0.38~0.18

47

> 0.96

< 10

0.96

UL, cUL

35

W2

PS

FSD-A32PBMws

120~277 0.39~0.18

46

> 0.98

< 10/20

0.88

UL, cUL

35

AA23

PS

FSD-B32PBMws

277~347 0.17~0.14

47

> 0.99

< 10

0.93

UL, cUL

35

AA23

PS

GSD-A32PBM

120~277 0.39~0.18

46

> 0.98

< 10/20

0.88

UL, cUL

35

AA24

PS

CSD-B42PBM

277~347 0.34~0.27

95

> 0.98

< 10

0.91

UL, cUL

33

AA20

PS

CSD-B42PS ws

277~347 0.34~0.27

95

> 0.98

< 10

0.91

UL, cUL

33

AA19

PS

CSD-UV42P

120~277 0.74~0.32

88

> 0.99

< 10/20

0.92

UL, cUL

33

AA19

PS

CSD-UV42P/BM

120~277 0.74~0.32

88

> 0.99

< 10/20

0.92

UL, cUL

33

AA21

PS

CSD-UV42PBM

120~277 0.74~0.32

88

> 0.99

< 10/20

0.92

UL, cUL

33

AA20

PS

EB-242T-UV-TP-PICws * 120~277 0.74~0.31

88

> 0.98

< 10

1.0

UL, cUL

33

T2

RS

EB-242T-UV-TP-PIC-DW *

120~277 0.70~0.30

84

> 0.98

< 10

0.90

UL, cUL

33

W2

RS

EB-242T-UV-TP-PSD*

120~277 0.70~0.30

84

> 0.98

< 10

0.90

UL, cUL

33

W2

PS

ESPQ-A42PS-S

120~277 0.74~0.32

88

> 0.99

< 10

0.90

UL, cUL

33

AA22

PS

FSD-B32PBMws

277~347 0.26~0.20

69

> 0.99

< 10

0.85

UL, cUL

33

AA23

PS

ESPQ-A42PS-S

120~277 1.32~0.60

163

> 0.99

< 10

0.90

UL, cUL

33

AA22

PS

120

0.54

* Ballast with bottom out connectors and with studs, Add /NS for case with bottom out connectors and without studs, Add /LS for case with lead wire out and with studs,
Add /NL for case with lead wire out and without
studs.
# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS
T5 Compact Lamps

57W

Lamp
Type

CFTR57W
/GX24q

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

CSD-B57PSHO

277~347 0.25~0.20

67

> 0.98

< 10

1.05

UL, cUL

35

AA26

PS

CSD-UV57P

120~277 0.48~0.22

58

> 0.98

< 10/25

0.84

UL, cUL

35

AA19

PS

CSD-UV57PBMS

120~277 0.46~0.21

58

> 0.98

< 10/20

0.85

UL, cUL

35

AA20

PS

CSD-UV57PS ws

EB-242T-UV-TP-PIC-DW

2
2

120~277 0.46~0.21

57

> 0.98

< 10/20

0.86

UL, cUL

35

AA19

PS

* 120~277 0.42~0.19

50

> 0.97

< 10

0.80

UL, cUL

33

W2

RS

CSD-B57PSHO

277~347 0.5~0.40

136

> 0.98

< 10

0.98

UL, cUL

33

AA26

PS

CSD-B70PS

277~347 0.41~0.33

112

> 0.99

< 10

0.90

UL, cUL

33

AA26

PS

CSD-UV57P

120~277 0.95~0.4

112

> 0.98

< 10/15

0.84

UL, cUL

33

AA19

PS

CSD-UV57PBMS

120~277 0.92~0.41

111

> 0.98

< 10/15

0.79

UL, cUL

33

AA20

PS

CSD-UV57PSws

120~277 0.92~0.41

111

> 0.98

< 10/15

0.79

UL, cUL

33

AA19

PS

CSD-UV70PBMS

120~277 0.99~0.43

119

> 0.99

< 10

0.93

UL, cUL

33

AA25

PS

CSD-UV70PSws

120~277 0.99~0.43

119

> 0.99

< 10

0.93

UL, cUL

33

AA26

PS

ESPQ-A42PS-S

120~277 1.32~0.60

163

> 0.99

< 10

0.90

UL, cUL

33

AA22

PS

* Ballast with bottom out connectors and with studs, Add /NS for case with bottom out connectors and without studs, Add /LS for case with lead wire out and with
studs, Add /NL for case with lead wire out and without
studs.
# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A31

Electronic
Ballast

ElectronicBallasts

A32

ELECTRONIC BALLAST FOR


COMPACT FLUORESCENT LAMPS

T5 Compact Lamps

Lamp
Watts

70W

Lamp
Type

No. of
Lamps

CFTR70WGXq

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

CSD-B70PS

277~347 0.28~0.22

77

> 0.99

< 10/15

0.99

UL, cUL

35

AA26

PS

CSD-UV57PBMS

120~277 0.52~0.23

63

> 0.98

< 10/20

0.79

UL, cUL

35

AA20

PS

CSD-UV57PSws

120~277 0.52~0.23

63

> 0.98

< 10/20

0.79

UL, cUL

35

AA19

PS

CSD-UV70PBMS

120~277 0.62~0.27

74

> 0.98

< 10/15

0.99

UL, cUL

35

AA25

PS

CSD-UV70PS

120~277 0.62~0.27

74

> 0.98

< 10/15

0.99

UL, cUL

35

AA26

PS

TSD-UV70P

120~277 0.63~0.27

74

> 0.99

< 10

0.95

UL, cUL

35

AA27

PS

CSD-B70PSws

277~347 0.55~0.44

150

> 0.99

< 10

0.95

UL, cUL

33

AA26

PS

CSD-UV70PBMS

120~277 1.2~0.52

145

> 0.99

< 10

0.92

UL, cUL

33

AA25

PS

CSD-UV70PSws

120~277 1.2~0.52

145

> 0.99

< 10

0.92

UL, cUL

33

AA26

PS

TSD-UV70P

120~277 1.2~0.52

144

> 0.99

< 10

0.87

UL, cUL

33

AA27

PS

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


LONGTWIN LAMPS 2G11 BASE
Long Twin Tube

24W

36W

Lamp
Type

FT24W
/2G11

FT36W
/2G11

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

120

0.43

Dimen Staring
-sions Method

EB-139HO-1-TP

28

> 0.50

< 150

1.00

UL, cUL

26

N1

RS

EB-224HO-UV-TP-PS 120~277 0.10~0.22

26

> 0.95

< 12

0.95

UL, cUL

37

U4

PS

EPSD-A40PBXM

27

> 0.97

< 10/30

0.90

UL, cUL

58

AA1

IS

EPD-340BXM

27

> 0.97

< 15

0.90

UL, cUL

58

AA1

IS

EB-224HO-UV-TP-PS 120~277 0.18~0.42

50

> 0.98

< 12

0.90

UL, cUL

36

U4

PS

EB-226-UV-TP-PSD

120~277 0.38~0.17

46

> 0.98

< 10

0.87

UL, cUL

33

W1

PS

EB-242T-UV-TP-PSD

120~277 0.45~0.20

54

> 0.98

< 10

1.00

UL, cUL

33

W2

PS

EB-242T-UV-TP-PIC-DW

120~277 0.45~0.20

54

> 0.98

< 10

1.00

UL, cUL

33

W2

RS

EPD-340BXM

44

> 0.98

< 15

0.82

UL, cUL

59

AA1

IS

EPSD-A40PBXM

120~277 0.37~0.17

44

> 0.99

< 10/15

0.82

UL, cUL

59

AA1

IS

FSD-A32PBMws

120~277 0.45~0.21

54

> 0.97

< 10/20

0.88

UL, cUL

33

AA23

PS

FSD-B32PBMws

277~347 0.20~0.16

54

> 0.99

< 10

0.88

UL, cUL

33

AA23

PS

GSD-A32PBM

120~277 0.45~0.21

54

> 0.97

< 10/20

0.88

UL, cUL

33

AA24

PS

CSD-UV42P

120~277 0.28~0.13

34

> 0.95

< 25/45

0.89

UL, cUL

35

AA19

PS

CSD-UV42P/BM

120~277 0.28~0.13

34

> 0.95

< 25/45

0.89

UL, cUL

35

AA21

PS

CSD-UV42PBM

120~277 0.28~0.13

34

> 0.95

< 25/45

0.89

UL, cUL

35

AA20

PS

EB-139HO-1-TP

120

0.48

33

> 0.50

< 150

0.90

UL, cUL

26

N1

RS

EB-1382D-1-TPws

120

0.56

37

> 0.50

< 150

0.95

UL, cUL

26

S1

RS

EB-1382D-1-TP-SC#

120

0.56

37

> 0.50

< 150

0.95

UL, cUL

26

L8

RS

EB-224HO-UV-TP-PS 120~277 0.33~0.15

40

> 0.95

< 12

1.0

UL, cUL

37

U4

RS

EB-242T-UV-TP-PSD

120~277 0.31~0.14

37

> 0.95

< 12

0.88

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW

120~277 0.31~0.14

37

> 0.95

< 12

0.88

UL, cUL

35

W2

RS

EPD-340BXM

34

> 0.98

< 15

0.89

UL, cUL

58

AA1

IS

EPSD-A40PBXM

120~277 0.27~0.13

34

> 0.98

< 10/15

0.84

UL, cUL

58

AA1

IS

FSD-A32PBMws

120~277 0.29~0.13

34

> 0.97

< 10/30

0.83

UL, cUL

35

AA23

PS

FSD-B32PBMws

277~347 0.13~0.1

34

> 0.99

< 10/15

0.82

UL, cUL

35

AA23

PS

GSD-A32PBM

120~277 0.29~0.13

34

> 0.97

< 10/30

0.83

UL, cUL

35

AA24

PS

120~277 0.23~0.11
347

347

347

0.06

0.13

0.10

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A33

Electronic
Ballast

ElectronicBallasts

A34

ELECTRONIC BALLAST FOR


LONGTWIN LAMPS 2G11 BASE

Long Twin Tube

Lamp
Watts

36W

Lamp
Type

FT36W/
2G11

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

CSD-B42PBMws

277~347 0.25~0.21

68

> 0.98

< 10/15

0.88

UL, cUL

33

AA20

PS

CSD-B42PSws

277~347 0.25~0.21

68

> 0.98

< 10/15

0.88

UL, cUL

33

AA19

PS

CSD-UV32P/BM

120~277 0.52~0.24

63

> 0.99

< 10/15

0.88

UL, cUL

33

AA18

PS

CSD-UV32PSX

120~277 0.52~0.24

63

> 0.99

< 10

0.88

UL, cUL

33

AA15

PS

CSD-UV42P

120~277 0.51~0.23

63

> 0.98

< 10/20

0.91

UL, cUL

33

AA19

PS

CSD-UV42P/BM

120~277 0.51~0.23

63

> 0.98

< 10/20

0.91

UL, cUL

33

AA21

PS

EB-239HO-UV-TP-PSws

120~277 0.62~0.27

74

> 0.98

< 10

0.95

UL, cUL

36

U4

PS

EB-242T-UV-TP-PSD 120~277 0.55~0.24

66

> 0.98

< 10

0.80

UL, cUL

33

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.55~0.24

66

> 0.98

< 10

0.80

UL, cUL

33

W2

RS

EPD-340BXM

54

> 0.99

< 10

0.78

UL, cUL

59

AA1

IS

EPSD-A40PBXM

56

> 0.99

< 10

0.76

UL, cUL

59

AA1

IS

EPT-340PBXM

64

> 0.99

< 10

0.69

UL, cUL

59

AA1

IS

FSD-A32PBMws

120~277 0.51~0.23

62

> 0.98

< 10/15

0.81

UL, cUL

33

AA23

PS

FSD-B32PBMws

277~347 0.23~0.19

63

> 0.99

< 10

0.80

UL, cUL

33

AA23

PS

GSD-A32PBM

120~277 0.51~0.23

62

> 0.98

< 10/15

0.81

UL, cUL

33

AA24

PS

EPT-340PBXM

85

> 0.99

< 10

0.76

UL, cUL

66

AA1

IS

347

0.156

120~277 0.46~0.20
347

347

0.18

0.24

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


LONGTWIN LAMPS 2G11 BASE
Long Twin Tube

40W

Lamp
Type

FT40W/
2G11RS

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

CSD-UV42P

120~277 0.36~0.17

43

> 0.97

< 20/35

0.91

UL, cUL

35

AA19

PS

CSD-UV42P/BM

120~277 0.36~0.17

43

> 0.95

< 20/35

0.91

UL, cUL

35

AA21

PS

CSD-UV42PBMws

120~277 0.36~0.17

EB-139HO-1-TP

EB-142T-1-TP-SC #

EB-242T-UV-TP-PSD

120~277 0.37~0.17

43

> 0.95

< 20/35

0.91

UL, cUL

35

AA20

PS

120

0.55

38

> 0.50

< 150

0.90

UL, cUL

26

N1

RS

120

0.56

39

> 0.50

< 120

0.85

UL, cUL

26

L8

RS

45

> 0.96

< 10

1.00

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.37~0.17

45

> 0.96

< 10

1.00

UL, cUL

35

W2

RS

EPD-132T8M

120

0.31

38

> 0.99

< 10

0.95

UL, cUL

35

AA27

IS

EPD-332T8M

347

0.11

39

> 0.99

< 10

0.98

UL, cUL

31

AA27

IS

EPD-340BXM

347

0.12

41

> 0.98

< 15

1.05

UL, cUL

58

AA1

IS

EPD-A32T8M

120~277 0.31~0.14

38

> 0.99

< 10/15

0.95

UL, cUL

35

AA27

IS

EPS-A32T8M

120~277 0.34~0.1

41

> 0.98

< 10/15

0.96

UL, cUL

AA27

RS

EPSD-A40PBXM

120~277 0.35~0.16

42

> 0.98

< 10/15

0.99

UL, cUL

58

AA1

IS

ESD-332T8M

41

> 0.96

< 20

0.96

UL, cUL

AA1

RS

FSD-A32PBMws

120~277 0.36~0.17

43

> 0.97

< 10/30

1.01

UL, cUL

35

AA23

PS

FSD-B32PBMws

277~347 0.16~0.13

43

> 0.99

< 15

1.04

UL, cUL

35

AA23

PS

GSD-A32PBM

120~277 0.36~0.17

43

> 0.97

< 10/30

1.01

UL, cUL

35

AA24

PS

CSD-B42PBMws

277~347 0.32~0.26

88

> 0.99

< 10

0.91

UL, cUL

33

AA20

PS

CSD-B42PS

277~347 0.32~0.26

88

> 0.99

< 10

0.91

UL, cUL

33

AA19

PS

CSD-UV42P

120~277 0.66~0.29

79

> 0.98

< 10/20

0.95

UL, cUL

33

AA19

PS

CSD-UV42P/BMws

120~277 0.66~0.29

80

> 0.98

< 10/20

0.85

UL, cUL

33

AA21

PS

CSD-UV42PBM

120~277 0.66~0.29

80

> 0.98

< 10/20

0.85

UL, cUL

33

AA20

PS

EB-242T-UV-TP-PSD

120~277 0.69~0.30

82

> 0.98

< 10

0.95

UL, cUL

33

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.69~0.30

82

> 0.98

< 10

0.95

UL, cUL

33

W2

RS

EPD-132T8M

120

0.50

58

> 0.99

< 10

0.75

UL, cUL

33

AA27

IS

EPD-332T8M

347

0.18

58

> 0.99

< 10

0.77

UL, cUL

12

AA27

IS

347

0.18

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A35

Electronic
Ballast

ElectronicBallasts

A36

ELECTRONIC BALLAST FOR


LONGTWIN LAMPS 2G11 BASE

Long Twin Tube

Lamp
Watts

40W

50W

Lamp
Type

FT40W/2
G11RS

FT50W/2
G11RS

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

EPD-340BXM

347

0.196

< 10

0.88

UL, cUL

59

AA1

IS

EPD-A32T8M

120~277

0.5~21

68
58

> 0.99

> 0.99

< 10/15

0.95

UL, cUL

12

AA27

IS

EPQ-132T8M

120

0.59

70

> 0.99

< 10

0.89

UL, cUL

33

AA27

IS

EPQ-A32T8M

120~277 0.59~0.28

70

> 0.97

< 10

0.89

UL, cUL

33

AA27

IS

EPS-A32T8M

120~277 0.53~0.28

64

> 0.98

< 10/15

0.76

UL, cUL

AA27

RS

EPSD-A40PBXM

120~277 0.57~0.25

68

> 0.99

< 10

0.88

UL, cUL

59

AA1

IS

EPT-132T8M

120

0.59

70

> 0.99

< 10

0.89

UL, cUL

33

AA27

IS

EPT-340PBXM

347

0.24

83

> 0.99

< 10

1.09

UL, cUL

59

AA1

IS

EPT-A32T8M

72

> 0.99

< 10

0.89

UL, cUL

12

AA27

IS

ESD-332T8M

347

0.28

64

> 0.99

< 15

0.76

UL, cUL

AA1

RS

EPQ-132T8M

120

0.77

93

> 0.99

< 10

0.82

UL, cUL

52

AA27

IS

EPQ-A32T8M

93

> 0.98

< 10

0.82

UL, cUL

52

AA27

IS

EPT-340PBXM

347

0.31

107

> 0.99

< 10

0.89

UL, cUL

66

AA1

IS

ESPQ-132T8HO

120

0.91

109

> 0.99

< 10

0.95

UL, cUL

57

AA22

RS

ESPQ-332T8HO

347

0.33

113

> 0.99

< 10

0.99

UL, cUL

57

AA22

RS

ESPQ-132T8HO

120

1.36

163

> 0.99

< 10

0.72

UL, cUL

42

AA22

RS

ESPQ-332T8HO

347

0.43

149

> 0.99

< 10

0.92

UL, cUL

42

AA22

RS

CSD-B42PBMws

277~347 0.17~0.14

> 0.97

< 10/20

0.78

UL, cUL

35

AA20

PS

CSD-UV42P

120~277 0.39~0.18

47
43

> 0.97

< 20/35

0.91

35

AA19

PS

CSD-UV42P/BM

120~277 0.39~0.18

48

> 0.98

< 20/35

0.88

UL, cUL

35

AA21

PS

CSD-UV42PBM

120~277 0.39~0.18

48

> 0.98

< 20/35

0.88

UL, cUL

35

AA20

PS

EB-154HO-1-TP

120

0.73

48

> 0.50

< 150

0.90

UL, cUL

26

N1

RS

EB-155-1-TP-SC#

120

0.82

58

> 0.50

< 150

1.0

UL, cUL

26

L8

RS

EB-254HO-UV-TP-PS 120~277 0.49~0.22

57

> 0.92

< 12

1.0

UL, cUL

37

U4

PS

EPD-A55PBXM

120~277 0.52~0.22

62

> 0.99

< 10

1.1

UL, cUL

58

AA1

IS

FSD-A32PBMws

120~277 0.40~0.18

48

> 0.98

< 10/20

0.8

UL, cUL

35

AA23

PS

FSD-B32PBMws

277~347 0.18~0.14

48

> 0.99

< 10

0.78

UL, cUL

35

AA23

PS

GSD-A32PBM

120~277 0.40~0.18

48

> 0.98

< 10/20

0.8

UL, cUL

35

AA24

PS

EB-254HO-UV-TP-PS 120~277 0.98~0.43

115

> 0.98

< 10

1.0

UL, cUL

36

U4

PS

EPD-A55PBXM

120~277 0.85~0.37

102

> 0.99

< 10

0.99

UL, cUL

59

AA1

IS

EPQ-A55PBX-S

120~277 0.85~0.37

102

> 0.99

< 10

0.99

UL, cUL

59

AA1

IS

EPD-A55PBXM

120~277 0.85~0.37

102

> 0.99

< 10

0.99

UL, cUL

59

AA1

IS

120~277 0.60~0.27

120~277 0.77~0.34

ws This item is well stocked


# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


LONGTWIN LAMPS 2G11 BASE
Long Twin Tube

55W

Lamp
Type

FT55W/2G11RS

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

CSD-B42PBMws

277~347 0.17~0.15

47

> 0.95

< 15/20

0.69

UL, cUL

35

AA20

PS

CSD-UV42P

120~277 0.36~0.16

44

> 0.95

< 20/35

0.67

UL, cUL

35

AA19

PS

CSD-UV42P/BMws

120~277 0.36~0.16

44

> 0.97

< 20/35

0.67

UL, cUL

35

AA21

PS

CSD-UV42PBMws

120~277 0.36~0.16

44

> 0.97

< 20/35

0.67

UL, cUL

35

AA20

PS

EB-154HO-1-TP

120

0.73

48

> 0.50

< 150

0.85

UL, cUL

35

NQ

RS

EB-155-1-TP-SC# ws

120

0.74

52

> 0.50

< 120

0.90

UL, cUL

26

L8

RS

EB-254HO-UV-TP-PS 120~277 0.46~0.21

55

> 0.92

< 12

0.86

UL, cUL

37

U4

PS

EPD-A55PBXM

120~277 0.52~0.22

62

> 0.99

< 10

1.1

UL, cUL

58

AA1

IS

EB-254HO-UV-TP-PS 120~277 0.90~0.38

106

> 0.99

< 10

0.85

UL, cUL

36

U4

PS

EPD-A55PBXM

62

> 0.99

< 10

1.1

UL, cUL

58

AA1

IS

120~277 0.52~0.22

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs.
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A37

Electronic
Ballast

ElectronicBallasts

A38

ELECTRONIC BALLAST FOR


CIRCLINE LAMPS

Circline Lamps

Lamp
Watts

Lamp
Type

22W

FC8T9

22W

30W

32W

40W

40W

FC9T5

FCL-30

FC12T9

FC12T5

FC16T9

22+32 FC8T9+FC12T9

22+40 FC9T5+FC12T5
32+40 FC12T9+FC16T9

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast Approvals Wiring Dimen Staring


Factor
Dia. -sions Method

EB-1C22-1-TP-WSws

120

0.33

21

> 0.50

< 150

0.90

UL, cUL

10

S1

RS

EB-1C22-1-TP-WS-LC

120

0.33

21

> 0.50

< 150

0.90

UL, cUL

10

L1

RS

EB-126-1-TP

120

0.34

22

> 0.50

< 150

1.0

UL, cUL

10

S1

RS

EB-126-1-TP-LC

120

0.34

22

> 0.50

< 150

1.0

UL, cUL

10

L2

RS

CSD-UV18Pws

120~277 0.17~0.08

21

> 0.97

< 15

1.08

UL, cUL

35

AA15

PS

CSD-UV-18PBM

120~277 0.17~0.08

21

> 0.98

< 15

1.08

UL, cUL

35

AA16

PS

EB-242T-UV-TP-PSD

120~277 0.27~0.13

31

> 0.93

< 15

1.2

UL, cUL

33

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.27~0.13

31

> 0.93

< 15

1.2

UL, cUL

33

W2

RS

EB-242T-UV-TP-PSD

120~277 0.49~0.22

59

> 0.97

< 10

1.1

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.49~0.22

59

> 0.97

< 10

1.1

UL, cUL

35

W2

RS

EB-1C3032-1-TP-WSws

120

0.50

32

> 0.50

< 150

0.95

UL, cUL

10

S1

RS

EB-1C3032-1-TP-WS-LC

120

0.50

32

> 0.50

< 150

0.95

UL, cUL

10

L2

RS

EB-1C3032-1-TP-WSws

120

0.55

37

> 0.50

< 150

1.0

UL, cUL

10

S1

RS

EB-1C3032-1-TP-WS-LC

120

0.55

37

> 0.50

< 150

1.0

UL, cUL

10

L2

RS

EB-1382D-1-TP-WS

120

0.62

41

> 0.50

< 150

0.95

UL, cUL

10

S1

RS

EB-1382D-1-TP-LC-WS

120

0.62

41

> 0.50

< 150

0.95

UL, cUL

10

L2

RS

EB-242T-UV-TP-PSD

120~277 0.37~0.17

45

> 0.96

< 10

1.0

UL, cUL

33

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.37~0.17

45

> 0.96

< 10

1.0

UL, cUL

33

W2

RS

EB-242T-UV-TP-PSD

120~277 0.69~0.30

82

> 0.97

< 10

0.95

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.69~0.30

82

> 0.97

< 10

0.95

UL, cUL

35

W2

PS

EB-226-UV-TP-PIC

120~277 0.36~0.16

42

> 0.97

< 10

1.0

UL, cUL

35

T1

RS

EB-226-UV-TP-PIC-DW 120~277 0.36~0.16

42

> 0.97

< 10

1.0

UL, cUL

35

W1

RS

EB-1382D-1-TP-WS

120

0.63

43

> 0.50

< 130

0.95

UL, cUL

10

S1

RS

EB-1382D-1-TP-LC-WS

120

0.63

43

> 0.50

< 130

0.95

UL, cUL

10

L2

RS

EB-2C72-1-TP-WS

120

0.60

40

> 0.50

< 150

0.76

UL, cUL

11

L1

RS

EB-2C54PS-1-TP-WS

120

0.68

48

> 0.50

< 130

0.85

UL, cUL

11

L1

PS

EB-242T-UV-TP-PSD

120~277 0.55~0.25

67

> 0.98

< 10

0.90

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.55~0.25

67

> 0.98

< 10

0.90

UL, cUL

35

W2

RS

EB-2C72-1-TP-WS

50

> 0.50

< 150

0.70

UL, cUL

11

L1

RS

120

0.75

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

ELECTRONIC BALLAST FOR


2D LAMPS
2D Lamps

Lamp
Type

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast Approvals Wiring Dimen Staring


Factor
Dia. -sions Method

2D

21W

28W

CFS28W/GR10q

CFS28W/GR10q

38W CFS38W/GR10q

EB-1C22-1-TP

120

0.30

19

> 0.50

< 150

0.85

UL, cUL

27

S1

RS

EB-1C22-1-TP-LC

120

0.30

19

> 0.50

< 150

0.85

UL, cUL

27

L1

RS

EB-218-UV-TP-PICws

120~277 0.20~0.09

24

> 0.95

< 12

1.05

UL, cUL

35

T1

RS

EB-218-UV-TP-PIC-DWws

120~277 0.20~0.09

24

> 095

< 12

1.05

UL, cUL

35

W1

RS

EB-118-1-TP-SC #

18

> 0.50

< 150

0.80

UL, cUL

27

L8

RS

EB-218-UV-TP-PSD

120~277 0.17~0.07

20

> 0.95

< 10

0.85

UL, cUL

35

W1

PS

EB-218-UV-TP-PSD

120~277 0.31~0.13

37

> 0.98

< 10

0.80

UL, cUL

33

W1

PS

EB-226-UV-TP-PSD

120~277 0.35~0.15

42

> 0.98

< 10

0.92

UL, cUL

33

W1

PS

EB-126-1-TP

120

0.40

28

> 0.50

< 130

0.90

UL, cUL

27

S1

RS

EB-142T-1-TP-SC #

120

0.45

30

> 0.50

< 130

0.95

UL, cUL

27

L8

RS

EB-218-UV-TP-PICws

120~277 0.26~0.12

31

> 0.97

< 10

1.0

UL, cUL

35

T1

RS

EB-218-UV-TP-PIC-DWws

120~277 0.26~0.12

31

> 0.97

< 10

1.0

UL, cUL

35

W1

RS

EB-226-UV-TP-PSD

120~277 0.25~0.11

30

> 0.97

< 10

0.95

UL, cUL

35

W1

PS

EB-242T-UV-TP-PSD

120~277 0.29~0.14

34

> 0.93

< 15

1.0

UL, cUL

35

W2

PS

EB-242T-UV-TP-PIC-DW 120~277 0.29~0.14

34

> 0.93

< 15

1.0

UL, cUL

35

W2

RS

EB-1382D-1-TPws

40

> 0.50

< 150

0.95

UL, cUL

27

S1

RS

120

120

0.28

0.60

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

Lamp
Watts

A39

Electronic
Ballast

ElectronicBallasts

A40

ELECTRONIC BALLAST FOR


ENERGY SAVING GU-24 LAMPS

GU24 Adapter Ballasts


Lamp
Watts

Lamp
Type

No. of
Lamps

13W
13W

CFQ13W/G24q

CFTR13W/GX24q

18W

CFQ18W/G24q

18W
26W

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast Approvals
Factor

Wiring
Dia.

Dimen Staring
-sions Method

EB-113-1-TP-AD

120

0.22

14

> 0.50

<150

1.02

UL, cUL

26

Y1

PH

EB-113-1-TP-AD

120

0.22

14

> 0.50

<150

1.02

UL, cUL

26

Y1

PH

EB-118-1-TP-AD

120

0.24

16

> 0.50

<150

0.85

UL, cUL

26

Y1

PH

CFTR18W/GX24Q

EB-118-1-TP-AD

120

0.24

16

> 0.50

<150

0.85

UL, cUL

26

Y1

PH

CFTR26W/GX24q

EB-126-1-TP-ADw

120

0.31

21

> 0.50

<150

0.80

UL, cUL

26

Y1

PS

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Electronic
Ballast

DIMMING BALLASTS

Dimming Ballast
Lamp
Watts

A41

Lamp
Type

No. of
Lamps

F28T5

EB-128-1-TP-LDIM

120

PENDING

F32T8

EB-132-1-TP-LDIM

120120

PENDING

CFQ26W/
G24q

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Factor

Approvals

Wiring
Dia.

Dimen Staring
-sions Method

T5
28W

T8
CFL
26W

EB-126-1-TP-DIM full power

120

0.31

31

0.840

< 150

1.05

UL, cUL

26

W1

RS

Least power

120

0.58

10

0.15

---

---

---

---

---

---

EB-1C30-1-TP-DIM full power

120

0.28

25

0.74

< 150

0.80

UL, cUL

10

S2

RS

Least power

120

0.55

0.15

---

---

---

---

---

---

120

0.85

0.85

59

0.57

< 150

RU, cRU

27

AC1

RS

120

0.49

29

0.50

---

---

---

---

---

---

CIRCLINE
30W

FCL-30

CFS55W/
GR10q

2D
55W

EB-1552D-1-TP-LDIM

Least power

full power

# replace -SC with -SCS for model with studs; with SC-RJ for model with bottom out leads; with -SC-RJS with bottom out leads and with studs
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

ElectronicBallasts

32W

Ballasts
Disconnects

A42

POWER-SAFE BALLASTDISCONNECTS

Ballast Disconnects
BD2-4

BD3-3

Ballast Disconnects

BD2-2

SIZESIN MM

Model
BD2-2

BD2-4

Electrical Rating
6 A/600V

SIZESIN MM

Wire Type

12 AWG - 18 AWG

12 AWG - 18 AWG

Stranded

12 AWG - 14 AWG

12 AWG - 14 AWG
19 strand or less

6 A/600V

6 A/600V

Wire Range Load Side

Solid

Stranded Tinned

BD3-3

Wire Range Line Side

SIZESIN MM

12 AWG
14 AWG
16 AWG
18 AWG

=/<
=/<
=/<
=/<

19
19
26
16

strand
strand
strand
strand

12 AWG
14 AWG
16 AWG
18 AWG

=/<
=/<
=/<
=/<

19
19
26
16

Quantity and
Packed

Cat No.

1,000 pcs - boxed


100 pcs - poly bagged
20 pcs - blister boxed

BD2-2
BD2-2/CPB
BD2-2/BB

1,000 pcs - boxed


100 pcs - poly bagged
strand
20 pcs - blister boxed
strand
strand
strand 1,000 pcs - boxed
100 pcs - poly bagged
20 pcs - blister boxed

BD2-4
BD2-4/CPB
B2-4/BB
BD3-3
BD3-3/CPB
BD3-3/BB

Specifications:
Housing: Polycarbonate (PC) Rated UL94 V-0
Contacts: Copper Alloy
Temp.Rating: Working temperature - 105C (221F).
Electrical Rating: 6A 600V on line side, 6A on load size
Strip Length: 3/8

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

POWER-SAFE BALLASTDISCONNECTS

Ballast
Disconnects

Ballast Disconnects

A43

Features:

Meets CEC and NEC code changes for non-residential fluorescent luminaires with ballasts
Perfect for fixture OEMs or retrofit lighting applications or facility maintenance electrical personnel.
Well designed. Color coded Push-in wire ports make wiring easy and quickly lock wires in place and can be
used with a wide range of either solid or stranded wire sizes.
Pieces pull apart safely with ease by simply pushing down on the integrated locking latch when needed for
ballast servicing without disconnecting the power.
Dead front design in all wiring areas which protects the installer from touching any live wires.
Fool-proof keyed design enables mating halves of the disconnect to be installed only one way, eliminating
possible incorrect polarization
Oversize electrical contacts which improve conductivity and reduce the temperature rise.
Some models can be daisy chained to wire to another ballast (BD2-4) or wired for dimming circuits (BD3-3)
Passes UL 2459 & CSA 182.3 finger probe requirements
Fits through 1/2 in. knockout.
Built in 3/8 in. strip length indicator

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Ballast Disconnects

The Etlin Daniels Power-Safe Luminaire Disconnects fully meets the 2008 National Electrical Code 410.130(G),
2005 NEC 410.73(G) and Canadian Electrical Code 30-308(4) for non-residential fluorescent luminaires. The ED
Ballast quick latch helps protect electricians from electrical shock hazard during ballast replacement by safely
disconnecting hot and neutral ballast wiring. Both halves of the BD Series meet UL finger-probe safety
requirements. The ED BD Series is available in 2-pole and 3-pole models with options for new installations or
ballast retrofitting. Quick wire push-in terminations provides fast, efficient ballast connections for faster installation
times and labor savings. There is no need for additional pigtails that require additional connectors and labor.

SECTION A
1850 Wilson Avenue, Toronto,
Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104
www.etlin.com

BALLASTS

MAGNETIC BALLASTS
A44

MAGNETIC BALLASTS

Electronic Ballasts
Ballast Disconnects
Magnetic Ballasts
T5 Straight Lamps
T8 Straight Lamps
T12 Straight Lamps
Compact Lamps
Circline Lamps
Sign Ballasts
Emergency Ballasts
Appendix: Wiring Diagrams & Case Styles
Appendix: Electronic Ballasts: Standard Lead Lengths & Standard Packaging
Suffix Guide

Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation.
While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,
no warranty is given in respect thereof and the company shall not be liable for any error herein.
Copyright 2011 Etlin-Daniels

A1-A41
A42-A43
A44
A45
A46-A47
A48-51
A52-A53
A54
A55
A56-A64
A65-A73
A74-A79
A80

Magnetic
Ballast

MagneticBallasts

A45

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS

T5 Straight Lamps

Lamp
Watts

Lamp
Type

4W

F4T5

6W

8W

13W

F6T5

F8T5

F13T5

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

CF-49-CC *

120

0.12

> 0.55

< 15

0.80

UL, cUL

B1

PH

CF-49-OC * %

120

0.12

> 0.55

< 15

0.80

UL, cUL

A1

PH

CF-49-CC ws *

120

0.12

> 0.55

< 15

0.80

UL, cUL

B1

PH

CF-49-OC * %

120

0.12

> 0.55

< 15

0.80

UL, cUL

A1

PH

CF-68T5-PG

120

0.15

> 0.45

< 20

0.80

UL, cUL

E2

PH

CF-49-CC ws *

120

0.12

> 0.50

< 15

0.80

UL, cUL

B1

PH

CF-49-OC * %

120

0.12

> 0.50

< 15

0.80

UL, cUL

A1

PH

CF-579-CC *

120

0.14

> 0.50

< 15

0.82

UL, cUL

B1

PH

CF-579-OC * %

120

0.14

> 0.50

< 15

0.82

UL, cUL

A1

PH

CF-68T5-PG

120

0.13

> 0.50

< 20

0.80

UL, cUL

E2

PH

N-113-1-TP-IES

120

0.17

10

> 0.50

< 20

0.97

UL, cUL

19

C6

IES

N-213-1-TP-IES

120

0.31

19

> 0.50

< 20

0.97

UL, cUL

20

J1

IES

N-113A-1-TP

120

0.28

17

> 0.50

< 15

0.84

UL, cUL

16

C6

PH

N-113A-1-TP-SS

120

0.28

17

> 0.50

< 15

0.84

UL, cUL

C6

PH

N-113-1-TP-IES

120

0.16

14

> 0.75

< 30

0.79

UL, cUL

19

J1

IES

CF-13T5-PG

120

0.17

16

> 0.80

< 30

0.80

UL, cUL

E3

PH

N-213-1-TP-IES

120

0.30

27

> 0.75

< 30

0.79

UL, cUL

20

J1

IES

* Add PF for single blow thermal fuse or Add TP for Class P type
% Replace OC by WC for With Cord model
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Magnetic
Ballast

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS
T8 Straight Lamps
Lamp
Watts

15W

17W

18W

25W

F14T8

F15T8

F17T8

F18T8

F25T8

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

CF-1322-CC ws *

120

0.33

16

> 0.40

< 15

0.80

UL, CSA

B2

PH

CF-1322-OC * %

120

0.33

16

> 0.40

< 15

0.80

UL, CSA

A2

PH

CF-1322M-CC ws *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

B2

PH

CF-1322M-OC * %

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

A2

PH

CF-1320S-CC ws *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

B4

PH

CF-1320S-OC ws * %

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

A4

PH

CF-1320LH-OC *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

A4

PH

CF-1320LH-CC *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

B4

PH

CF-1322-CC ws *

120

0.27

17

> 0.50

< 15

0.82

UL, CSA

B2

PH

CF-1322-OC * %

120

0.27

17

> 0.50

< 15

0.82

UL, CSA

A2

PH

CF-1322M-CC ws *

120

0.27

17

> 0.50

< 15

0.86

UL, CSA

B2

PH

CF-1322M-OC * %

120

0.27

17

> 0.50

< 15

0.86

UL, cUL

A2

PH

CF-1320S-CC ws *

120

0.27

17

> 0.50

< 20

0.82

UL, cUL

B4

PH

CF-1320S-OC ws * %

120

0.27

17

> 0.50

< 20

0.82

UL, cUL

A4

PH

CF-1320LH-OC *

120

0.27

17

> 0.50

< 20

0.82

UL, cUL

A4

PH

CF-1320LH-CC *

120

0.27

17

> 0.50

< 20

0.82

UL, cUL

B4

PH

N-120-1-TP ws

120

0.63

31

> 0.40

< 10

1.0

UL, cUL

D1

TS

CF-1540-1-TP-IES ws

120

0.32

17

> 0.45

< 30

0.93

UL, cUL

19

C7

IES

N-220-1-TP ws

120

0.65

35

> 0.45

< 20

0.70

UL, cUL

C1

TS

N-117-1-TP ws

120

0.44

23

> 0.45

< 20

0.95

UL, cUL

D1

RS

N-117SL-1-TP

120

0.44

23

> 0.45

< 20

0.95

UL, cUL

C6/J1

RS

N-117-1-TP-HP

120

0.21

23

> 0.90

< 20

0.95

UL, cUL

D1

RS

CF-1322-CC ws *

120

0.23

15

> 0.55

< 15

0.68

UL, cUL

B2

PH

CF-1322-OC * %

120

0.23

15

> 0.55

< 15

0.68

UL, CSA

A2

PH

CF-1322M-CC ws *

120

0.23

15

> 0.55

< 15

0.68

UL, CSA

B2

PH

CF-1322M-OC * %

120

0.23

15

> 0.55

< 15

0.71

UL, cUL

A2

PH

CF-1320S-CC ws *

120

0.23

15

> 0.55

< 15

0.71

UL, cUL

B4

PH

CF-1320S-OC * %

120

0.23

15

> 0.55

< 15

0.68

UL, cUL

A4

PH

CF-1320LH-OC *

120

0.23

15

> 0.55

< 15

0.68

UL, cUL

A4

PH

CF-1320LH-CC *

120

0.23

15

> 0.55

< 15

0.68

UL, cUL

B4

PH

N-125-1-TP ws

120

0.51

31

> 0.50

< 20

0.95

UL, cUL

D1

RS

N-125SL-1-TP

120

0.51

31

> 0.50

< 20

0.95

UL, cUL

C6/J1

RS

N-125-1-TP-HP

120

0.28

31

> 0.90

< 20

0.95

UL, cUL

D1

RS

No. of
Lamps

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

* Add PF for single blow thermal fuse or Add TP for Class P type
% Replace OC by WC for With Cord model
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

MagneticBallasts

14W

Lamp
Type

A46

Magnetic
Ballast

MagneticBallasts

A47

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS

T8 Straight Lamps

Lamp
Watts

30W

32W

Lamp
Type

F30T8

F32T8

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

N-140A-1-TP ws

120

0.60

36

> 0.50

< 15

0.88

UL, cUL

16

D1

PH

N-140A-1-TP-SS

120

0.60

36

> 0.50

< 15

0.88

UL, cUL

D1

PH

N-140A-1-TP-WC

120

0.60

36

> 0.50

< 15

0.88

UL, cUL

17

D1

PH

N-132-1-TP ws

120

0.52

33

> 0.50

< 20

0.84

UL, cUL

D1

RS

N-132SL-1-TP

120

0.52

33

> 0.50

< 20

0.84

UL, cUL

C6/J1

RS

N-132-1-TP-HP

120

0.31

33

> 0.90

< 20

0.84

UL, cUL

D1

RS

ES-232-1-TP ws

120

0.65

70

> 0.90

< 10

0.90

UL, cUL

C2

RS

ES-232-2-TP

277

0.28

70

> 0.90

< 10

0.90

UL, cUL

C2

RS

No. of
Lamps

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Magnetic
Ballast

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS
T12 Straight Lamps

14W

15W

20W

25W

Lamp
Type

F14T12

F15T12

F20T12

F25T12

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

CF-1322-CCWS *

120

0.33

16

> 0.40

< 15

0.80

UL, CSA

B2

PH

CF-1322-OC * %

120

0.33

16

> 0.40

< 15

0.80

UL, CSA

A2

PH

CF-1322M-CC ws *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

B2

PH

CF-1322M-OC * %

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

A2

PH

CF-1320S-CC ws *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

B4

PH

CF-1320S-OC ws * %

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

A4

PH

CF-1320LH-OC *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

A4

PH

CF-1320LH-CC *

120

0.33

16

> 0.40

< 15

0.80

UL, cUL

B4

PH

N-120-1-TP ws

120

0.69

29

> 0.35

< 10

0.93

UL, cUL

D1

TS

CF-1322-CC ws *

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

B2

PH

CF-1322-OC * %

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

A2

PH

CF-1322M-CC ws *

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

B2

PH

CF-1322M-OC * %

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

A2

PH

CF-1320S-CC ws *

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

B4

PH

CF-1320S-OC ws * %

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

A4

PH

CF-1320LH-OC *

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

A4

PH

CF-1320LH-CC *

120

0.32

17

> 0.45

< 15

0.85

UL, cUL

B4

PH

CF-1540-1-TP-IES ws

120

0.35

17

> 0.40

< 20

0.90

UL, cUL

19

C7

IES

N-120-1-TP ws

120

0.63

31

> 0.40

< 10

1.0

UL, cUL

D1

TS

N-220-1-TP ws

120

0.65

35

> 0.45

< 20

0.70

UL, cUL

C1

TS

CF-1322-CC ws *

120

0.24

17

> 0.60

< 15

0.65

UL, CSA

B2

PH

CF-1322-OC * %

120

0.24

17

> 0.60

< 15

0.65

UL, CSA

A2

PH

CF-1322M-CCWS *

120

0.24

17

> 0.60

< 15

0.65

UL, cUL

B2

PH

CF-1322M-OC * %

120

0.24

17

> 0.60

< 15

0.65

UL, cUL

A2

PH

CF-1320S-CC ws *

120

0.24

17

> 0.60

< 15

0.65

UL, cUL

B4

PH

CF-1320S-OC ws * %

120

0.24

17

> 0.60

< 15

0.65

UL, cUL

A4

PH

CF-1320LH-OC *

120

0.24

17

> 0.60

< 15

0.65

UL, cUL

A4

PH

CF-1320LH-CC *

120

0.24

17

> 0.60

< 15

0.65

UL, cUL

B4

PH

CF-1540-1-TP-IES ws

120

0.33

20

> 0.50

< 25

0.83

UL, cUL

19

C7

IES

N-120-1-TP ws

120

0.62

30

> 0.40

< 10

0.85

UL, cUL

D1

TS

N-220-1-TP ws

120

0.59

35

> 0.50

< 20

0.54

UL, cUL

C1

TS

CF-25-WC-TP

120

0.31

22

> 0.60

< 20

0.70

UL, cUL

17

G2

PH

* Add PF for single blow thermal fuse or TP for resettable thermal protector
# Add WS for standard bi-pin lampholders attached
WS This item is well stocked

% Replace OC by WC for With Cord model


@ Add LC for using 9 long can

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

MagneticBallasts

Lamp
Watts

A48

Magnetic
Ballast

MagneticBallasts

A49

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS

T12 Straight Lamps

Lamp
Watts

30W

25W

Lamp
Type

F30T12

F40T12

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

N-140A-1-TP ws

120

0.67

35

> 0.40

< 10

0.87

UL, cUL

16

D1

PH

N-140A-1-TP-SS

120

0.67

35

> 0.40

< 10

0.87

UL, cUL

D1

PH

N-140A-1-TP-WC

120

0.67

35

> 0.40

< 10

0.87

UL, cUL

17

D1

PH

N-140-1-TP ws

120

0.61

33

> 0.45

< 10

0.95

UL, cUL

D1

RS

CF-1540-1-TP-IES ws

120

0.33

20

> 0.50

< 25

0.83

UL, cUL

19

C7

IES

ES-240J-1-TP

120

0.66

75

> 0.95

< 20

0.97

UL, cUL

C2

RS

ES-230-1-TP

120

0.55

64

> 0.95

< 20

0.75

UL, cUL

C2

RS

N-140-1-TP ws

120

0.55

30

> 0.45

< 10

0.70

UL, cUL

D1

RS

CF-1540-1-TP-IES ws

120

0.31

30

> 0.80

< 40

0.66

UL, cUL

19

C7

IES

N-240-1-TP # @

120

0.58

45

> 0.65

< 20

0.50

UL, cUL

C7

RS

N-234-1-TP # @

120

0.52

41

> 0.65

< 20

0.36

UL, cUL

C7

RS

N-240-1-TP-IES

120

0.64

58

> 0.75

< 40

0.60

UL, cUL

20

D1

IES

LW-240-1-TP

120

0.58

66

> 0.95

< 30

0.67

UL, cUL

C2

RS

No. of
Lamps

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

# Add WS for standard bi-pin lampholders attached @ Add LC for using 9 long can
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Magnetic
Ballast

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS
T12 Straight Lamps

34W

40W

Lamp
Type

F40T12
Energy
SaverF30T8

F40T12

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

N-140-1-TP ws

120

0.63

34

> 0.45

< 10

0.70

UL, cUL

D1

PH

CF1540-TP-IES ws

120

0.38

25

> 0.50

< 40

0.69

UL, cUL

19

C7

IES

ES-140N-1-TP ws

120

0.38

44

> 0.95

< 15

0.88

UL, cUL

C2

RS

ES-140N-2-TP

277

0.17

46

> 0.95

< 15

0.90

UL, cUL

C2

RS

N-234-1-TP # @

120

0.80

53

> 0.5

< 15

0.60

UL, cUL

C1

RS

LW-240-1-TP

120

0.47

51

> 0.90

< 40

0.60

UL, cUL

C2

RS

N-240-1-TP-IES

120

0.70

51

> 0.60

< 40

0.60

UL, cUL

20

D1

IES

ES-240N-1-TP

120

0.64

75

> 0.95

< 25

0.88

UL, cUL

C2

RS

ES-240J-1-TP

120

0.70

76

> 0.90

< 20

0.88

UL, cUL

C2

RS

ES-240N-2-TP

277

0.30

78

> 0.95

< 20

0.90

UL, cUL

C2

RS

ES-240N-3-TP

347

0.22

76

> 0.95

< 20

0.90

UL, cUL

C2

RS

N-140-1-TP ws

120

0.61

37

> 0.50

< 10

0.64

UL, cUL

D1

PH

N-140A-1-TP ws

120

0.60

36

> 0.50

< 10

0.72

UL, cUL

16

D1

PH

N-140A-1-TP-SS

120

0.60

36

> 0.50

< 10

0.72

UL, cUL

D1

PH

N-140A-1-TP-WC

120

0.60

36

> 0.50

< 10

0.72

UL, cUL

17

G1

PH

CF-1540-1-TP-IES ws

0.31

30

> 0.80

< 40

0.66

UL, cUL

19

C7

IES

ES-140N-1-TP ws

120

0.44

51

> 0.95

< 15

0.93

UL, cUL

C2

RS

ES-140N-2-TP

277

0.19

52

> 0.95

< 15

0.94

UL, cUL

C2

RS

N-240-1-TP # @

120

0.64

50

> 0.65

< 20

0.45

UL, cUL

C1

RS

N-234-1-TP # @

120

0.52

41

> 0.50

< 20

0.36

UL, cUL

C1

RS

N-240-1-TP-IES

120

0.65

59

> 0.75

< 40

0.60

UL, cUL

20

D1

IES

ES-240N-1-TP

120

0.77

88

> 0.95

< 20

0.91

UL, cUL

C2

RS

LW-240-1-TP

120

0.57

66

> 0.95

< 30

0.67

UL, cUL

C2

RS

ES-240J-1-TP

120

0.77

88

> 0.95

< 20

0.90

UL, cUL

C2

RS

LE-240-1-TP

120

0.68

80

> 0.95

< 20

0.81

UL, cUL

C2

RS

ES-240N-2-TP

277

0.33

88

> 0.95

< 20

0.91

UL, cUL

C2

RS

ES-240N-3-TP

347

0.25

86

> 0.95

< 20

0.90

UL, cUL

C2

RS

120

# Add WS for standard bi-pin lampholders attached @ Add LC for using 9 long can
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

MagneticBallasts

Lamp
Watts

A50

Magnetic
Ballast

A51

T12 Straight Lamps


Lamp
Watts

MagneticBallasts

MAGNETIC BALLASTS FOR


FLUORESCENT LAMPS

55W

60W

75W

85W

96W

110W

Lamp
Type

F72T12

F96T12
Energy Saver

F96T12

F72T12/HO

F96T12/HO ES
Energy Saver

F96T12/HO

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

ES-196-1-TP ws

120

0.73

78

< 0.90

< 30

0.80

UL, cUL

25

D4

IS

ES-196-2-TP

277

0.30

76

< 0.90

< 35

0.80

UL, cUL

25

D4

IS

ES-275-1-TP ws *

120

0.90

98

< 0.90

< 40

0.68

UL, cUL

D2,D4

IS

ES-296N-1-TP

120

1.20

133

< 0.95

< 25

0.88

UL, cUL

D2

IS

ES-296-2-TP

277

0.51

133

< 0.95

< 25

0.90

UL, CSA

15

D2

IS

ES-296-3-TP

347

0.40

130

< 0.95

< 40

0.90

PENDING

15

D2

IS

ES-196-1-TP ws

120

0.73

78

< 0.90

< 40

0.71

UL, cUL

25

D4

IS

ES-196-2-TP

277

0.30

76

< 0.90

< 40

0.73

UL, cUL

25

D4

IS

ES-275-1-TP ws *

120

1.1

127

< 0.90

< 30

0.72

UL, cUL

D2,D4

IS

ES-296N-1-TP

120

1.20

133

< 0.95

< 25

0.88

UL, cUL

D2

IS

ES-296-2-TP

277

0.53

131

< 0.90

< 40

0.74

UL, cUL

15

D2

IS

ES-296-3-TP

347

0.40

132

< 0.90

< 40

0.90

PENDING

15

D2

IS

ES-196-1-TP ws

120

0.83

93

< 0.90

< 30

0.75

UL, cUL

25

D4

IS

ES-275-1-TP ws *

120

1.36

158

< 0.95

< 30

0.75

UL, cUL

D2,D4

IS

ES-196-2-TP

277

0.36

93

< 0.90

< 40

0.76

UL, cUL

25

D4

IS

ES-296N-1-TP

120

1.40

160

< 0.95

< 25

1.0

UL, cUL

D2

IS

ES-296-2-TP

277

0.53

131

< 0.90

< 40

0.74

UL, CSA

15

D2

IS

ES-296-3-TP

347

0.46

154

< 0.95

< 40

0.90

PENDING

15

D2

IS

ES-196HO-1-TP ws

120

1.1

123

< 0.90

< 35

1.0

UL, cUL

D8

RS

ES-196HO-2-TP

277

0.46

118

< 0.90

< 35

0.97

UL, cUL

D8

RS

ES-296HO-1-TP ws

120

1.85

207

< 0.90

< 20

0.94

UL, cUL

D8

RS

ES-296HO-2-TP

277

0.76

202

< 0.95

< 25

0.94

UL, cUL

D8

RS

ES-296HO-3-TP

347

0.54

186

< 0.95

< 40

0.86

UL, cUL

D8

RS

ES-196HO-1-TP

120

1.4

155

< 0.90

< 40

1.0

UL, cUL

D8

RS

ES-196HO-2-TP

277

0.50

123

< 0.90

< 40

0.91

UL, cUL

D8

RS

ES-296HO-1-TP ws

120

1.95

220

< 0.92

< 20

0.93

UL, cUL

D8

RS

ES-296HO-2-TP

277

0.78

210

< 0.95

< 15

0.90

UL, cUL

D8

RS

ES-296HO-3-TP

347

0.57

195

< 0.95

< 20

0.82

UL, cUL

D8

RS

ES-196HO-1-TP

120

1.2

130

< 0.90

< 40

0.95

UL, cUL

D8

RS

ES-196HO-2-TP

277

0.58

147

< 0.90

< 40

0.98

UL, cUL

D8

RS

ES-296HO-1-TP

120

2.2

260

< 0.95

< 10

0.95

UL, cUL

D8

RS

ES-296HO-2-TP

277

0.94

254

< 0.95

< 10

0.95

UL, cUL

D8

RS

ES-296HO-3-TP

347

0.65

230

< 0.95

< 20

0.86

UL, cUL

D8

RS

* For model without thermal protector, remove TP suffix


ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

A_Ballastspgs44-55_HID Ballasts.qxd 12-04-16 9:50 AM Page 9

Magnetic
Ballast

MAGNETIC BALLASTS FOR


COMPACT FLUORESCENT LAMPS
Compact Fluoescent Lamps

5W

7W

9W

13W

Lamp
Type

CFT5W/G23

CFT7W/G23

CFT9W/G23

CFT13W/GX23,
CFQ13W/GX23

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

CF-49-OC-TP %

120

0.13

> 0.50

< 15

0.77

UL, cUL

A1

PH

CF-49-CC-TP ws %

120

0.13

> 0.50

< 15

0.77

UL, cUL

B1

PH

CF-49M-1-OC *

120

0.20

9.5

0.40

< 15

1.12

UL, cUL

A2

PH

CF-79-CC-TPws

120

0.15

9.1

0.50

15

0.80

UL, cUL

61

--

PH

CF-49-OC-TP %

120

0.13

> 0.50

< 15

0.77

UL, cUL

A1

PH

CF-49-CC-TP ws %

120

0.13

> 0.50

< 15

0.77

UL, cUL

B1

PH

CF-49M-1-OC *

120

0.18

10.5

0.49

< 15

1.0

UL, cUL

A2

PH

CF-49M-1-CC *

120

0.18

10.5

0.49

< 15

1.0

UL, cUL

B2

PH

CF-79-CC-TPws

120

0.15

9.1

0.50

15

0.80

UL, cUL

61

--

PH

CF-579-CC-TP

120

0.15

> 0.50

< 15

0.87

UL, cUL

A1

PH

CF-49-OC-TP %

120

0.15

> 0.50

< 15

0.77

UL, cUL

A1

PH

CF-49-CC-TP ws %

120

0.15

> 0.50

< 15

0.77

UL, cUL

B1

PH

CF-49M-1-OC *

120

0.15

> 0.50

< 15

0.90

UL, cUL

A2

PH

CF-49M-1-CC *

120

0.15

> 0.50

< 15

0.90

UL, cUL

B2

PH

CF-79-CC-TPws

120

0.15

9.1

0.50

15

0.80

UL, cUL

61

--

PH

CF-579-CC-TP

120

0.15

> 0.50

< 15

0.75

UL, cUL

B1

PH

CF-1322-OC-TP %

120

0.30

16

> 0.45

< 15

0.93

UL, CSA

A2

PH

CF-1322-CC-TP ws

120

0.30

16

> 0.45

< 15

0.93

UL, CSA

B2

PH

CF-1322M-OC-TP %

120

0.26

16

> 0.50

< 15

0.93

UL, CSA

A2

PH

CF-1322M-CC-TP ws

120

0.26

16

> 0.50

< 15

0.93

UL, CSA

B2

PH

CF-1322-WC-TP

120

0.26

16

> 0.50

< 15

0.90

UL, cUL

17

G2

PH

CF-1322-PG-TP

120

0.26

16

> 0.50

< 15

0.90

UL, cUL

17

E1

PH

CF-1320S-OC-TP %

120

0.26

16

> 0.50

< 20

0.90

UL, cUL

A4

PH

CF-1320S-CC-TP

120

0.26

16

> 0.50

< 20

0.90

UL, cUL

B4

PH

CF-13-HP-TP

120

0.13

15

> 0.90

< 10

0.88

UL, cUL

C3

PH

CF-13S-HP-TP +

120

0.13

15

> 0.90

< 10

0.88

UL, cUL

C7

PH

CF-13-2-OC-TP

277

0.27

20

0.25

< 10

1.0

UL, cUL

A3

PH

CF-13-2-CC-TP

277

0.27

20

0.25

< 10

1.0

UL, cUL

D3

PH

CF-13-2-HP-TP +

277

0.08

20

0.90

< 10

1.0

UL, cUL

D3

PH

CF-213S-HP-TP

120

0.25

30

> 0.95

< 30

0.90

UL, cUL

18

D3

PH

CF-213-2-TP

277

0.22

31

> 0.50

< 30

0.90

UL, cUL

24

D3

PH

CF-213-2-HP-TP

277

0.12

31

> 0.95

< 25

0.90

UL, cUL

23

D3

PH

No. of
Lamps

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

% Replace OC by WC for With Cord model


+ Add RJ for Recessed Downlight J-Box Mounting. See CASE H
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

MagneticBallasts

Lamp
Watts

A52

Magnetic
Ballast

MagneticBallasts

A53

MAGNETIC BALLASTS FOR


COMPACT FLUORESCENT LAMPS

Compact Fluoescent Lamps

Lamp
Watts

18W

26W

27W

Lamp
Type

CFQ18W/G24d

CFQ26W/G24d

CFQ27W/GX32d

No. of
Lamps

Cat.
Number

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

CF-118-1-TP

120

0.35

21

> 0.50

< 30

0.87

UL, cUL

C6

PH

CF-118-1-HP-TP

120

0.18

21

> 0.95

< 30

0.87

UL, cUL

D1

PH

CF-118-2-OC-TP

277

0.24

24

> 0.35

< 30

0.90

UL, cUL

A3

PH

CF-218-1-HP-TP ws+

120

0.42

45

> 0.90

< 15

0.87

UL, cUL

23

C1

PH

CF-126-1-TP

120

0.59

32

> 0.45

< 15

0.85

UL, cUL

D1

PH

CF-126-1-HP-TP ws

120

0.28

32

> 0.95

< 30

0.89

UL, cUL

D1

PH

CF-126-2-OC-TP

277

0.28

31

> 0.40

< 15

0.91

UL, cUL

A3

PH

CF-226-1-HP-TP +

120

0.50

57

> 0.95

< 30

0.80

UL, cUL

23

C1

PH

CF-128-OC-TP

120

0.53

29

> 0.45

< 25

0.90

UL, cUL

A3

PH

CF-128-EN-TP

120

0.53

29

> 0.45

< 25

0.90

UL, cUL

D3

PH

CF-128-HP-TP

120

0.25

29

> 0.95

< 30

0.90

UL, cUL

D3

PH

% Replace OC by WC for With Cord model


+ Add RJ for Recessed Downlight J-Box Mounting. See CASE H
ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Magnetic
Ballast

MAGNETIC BALLASTS FOR


COMPACT FLUORESCENT LAMPS
Circline Lamps

20W

22W

Lamp
Type

Input
Volts

Input
Current

Input
Watts

Power
Factor

THD
%

Ballast
Wiring Dimen Staring
Approvals
Factor
Dia. -sions Method

CF-1322-OC-TP

120

0.30

16

> 0.45

< 15

0.73

UL, cUL

A2

PH

CF-1322-CC-TP

120

0.30

16

> 0.45

< 15

0.73

UL, cUL

B2

PH

CF-22-WS-TP ws

120

0.35

21

> 0.50

< 20

0.79

UL, cUL

10

C7

PH

CF-22-WS-TP ws

120

0.29

19

> 0.50

< 15

0.79

UL, cUL

10

C7

PH

N-122-1-TP-WS

120

0.49

24

> 0.40

< 10

0.72

UL, cUL

10

D1

RS

CF-1540-1-TP-IES ws

120

0.35

21

> 0.50

< 30

0.82

UL, cUL

19

C7

IES

CF-1322-CC-TP

120

0.30

18

> 0.50

< 15

0.70

UL, cUL

B2

PH

CF-1322-CC-PF

120

0.30

18

> 0.50

< 15

0.70

UL, cUL

B2

PH

CF-1540-1-TP-IES ws

120

0.40

29

> 0.60

< 40

0.73

UL, cUL

19

C7

IES

N-140-1-TP-WS ws

120

0.58

32

> 0.40

< 15

0.64

UL, cUL

10

D1

RS

CF-1540-1-TP-IES ws

120

0.37

33

> 0.75

< 45

0.70

UL, cUL

19

D7

IES

N-140-1-TP-WS ws

120

0.52

33

> 0.50

< 15

0.58

UL, cUL

10

D1

RS

FC8T9 &
FC12T9

N-2232-1-TP-WS

120

0.61

45

> 0.50

< 15

0.62

UL, cUL

11

C1

RS

ES-3240-1-TP-WS ws

120

0.44

51

> 0.95

< 20

0.72

UL, cUL

11

C1

RS

FC12T9 &
FC16T9

N-3240-1-TP-WS

120

0.55

63

> 0.95

< 25

0.69

UL, cUL

11

C1

RS

ES-3240-1-TP-WS ws

120

0.56

66

> 0.95

< 25

0.72

UL, cUL

11

C1

RS

FC6T9

FC8T9

FC12T9

40W

FC16T9

32&40W

Cat.
Number

32W

22&32W

No. of
Lamps

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

MagneticBallasts

Lamp
Watts

A54

Magnetic
Ballasts

A55

MAGNETICBALLASTS

Sign Ballasts
Lamp Footage

MagneticBallasts

No. of
Lamps

Cat.
Number

Input
Volts/Hz

Max. Line
Current
(Amps)

Max. Input
Power
(Watts

Open
Circuit
Volts)

Approvals

Wiring Dia. Dimensions

Min

Max

1,2

12

SB-0412-12-1-TP

120/60

1.48

175W

460V

UL, cUL

5, 39

D8

2,3,4

20

SB-0620-24-1-TP

120/60

2.56

304W

600V

UL, cUL

40, 41, 42

D8

2,3,4

12

24

SB-1224-24-1-TP

120/60

2.70

312W

765V

UL, cUL

40, 41, 42

D9

2,3,4

20

40

SB-2040-24-1-TP

120/60

4.00

472W

720V

UL, cUL

40, 41, 42

D10

4,5,6

12

40

SB-1240-46-1-TP

120/60

3.90

462W

720V

UL, cUL

43, 44, 45

D10

4,5,6

24

48

SB-2448-46-1-TP

120/60

4.50

530W

720V

UL, cUL

43, 44, 45

D10

ws This item is well stocked

Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

SECTION A
1850 Wilson Avenue, Toronto,
Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104
www.etlin.com

BALLASTS

EMERGENCY BALLASTS
A56

EMERGENCY BALLASTS

Elecrtronic Ballasts
Ballast Disconnects
Magnetic Ballasts
Emergency Ballasts for Linear Flourescent
500 Lumens - Linear Flourescent Ballasts
650 Lumens - Compact Flourescent Ballasts
700 Lumens - Linear Flourescent Ballasts
1300 Lumens
Appendix - Wiring Diagrams & Case Styles
Appendix: Electronic Ballasts: Standard Lead Lengths & Standard Packaging
Suffix Guide

Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation.
While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,
no warranty is given in respect thereof and the company shall not be liable for any error herein.
Copyright 2011 Etlin-Daniels

A1-A43
A42-A43
A44-A55
A56
A57
A58-61
A62-A63
A64
A65-A73
A74-A79
A80

Emergency
Ballast

EmergencyBallasts

A57

EMERGENCY BALLASTS FOR


LINEAR FLUORESCENT LAMPS

EB-500 Linear Fluorescent Emergency Ballast500 Lumens


The Etlin-Daniels EB-500 is a UL listed fluorescent lamp emergency
ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB500 immediately
switches to the emergency mode and operates one of the existing lamps
for 90 minutes. When the power is restored, the unit automatically goes
into recharge mode and features a time delay to prevent false tripping at
lamp end of life. The unit contains an internal long life maintenance free
Nickel Cadmium battery, charger, and electronic inverter circuit in a
compact metal case.

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 500 lumens
For indoor applications.
AC input power rating: 2.1 Watts
Charging indicator light: LED.

Lamps operated: most 2' to 4' single Bipin T8-T12, U


bend
or circline, Rapid or Instant start.
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 1.8 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

F17T8

450

F32T8

475

F20T12

425

F40T12

450

40W Biax

450

F40T12 Circline

450

The EB-500 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-500 is warranted for a period of 3 years from the date of purchase. This warranty covers only properly installed
emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or replace
without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our inspection
determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's exclusive
warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Emergency
Ballast

EMERGENCY BALLASTS FOR


COMPACT FLUORESCENT LAMPS
EB-650C2-A Compact Fluorescent Emergency Ballast650 Lumens

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 650 lumens
For indoor appications.
AC input power rating: 2.5 Watts
Charging indicator light: LED.

Lamps operated: most 18W and 26W quad tube CF


2-PIN lamps with integral starter or circline, Rapid or
Instant start.
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 3.2 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

18W PL CF 2-PIN

550

26W PL CF 2-PIN

650

The EB-650C2-A does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB650C2-A is warranted for a period of 3 years from the date of purchase. This warranty covers only properly
installed emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or
replace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our
inspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's
exclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

EmergencyBallasts

The Etlin-Daniels EB650C2-A is a UL listed fluorescent lamp emergency


ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB-650C2-A immediately
switches to the emergency mode and operates one of the existing
lamps for 90 minutes. When the power is restored the unit automatically
goes into recharge mode and features a time delay to prevent false tripping
at lamp end of life. The unit contains an internal long life maintenance
free Nickel Cadmium battery, charger, and electronic inverter
circuit in a compact metal case. The EB-650C2-A can be used with most
18 & 26 Watt quad tube 2-PIN LAMPS with an initial output of up to
650 lumens. The EB-650C2-A provides dual 3/8" flexible conduits, one
for the fixture or ballast compartment and the other to the switch box
which includes the test switch, charge light, and unit battery connector.

A58

Emergency
Ballast

EmergencyBallasts

A59

EMERGENCY BALLASTS FOR


COMPACT FLUORESCENT LAMPS

EB-650C2-B Compact Fluorescent Emergency Ballast650 Lumens


The Etlin-Daniels EB650C2-B is a UL listed fluorescent lamp emergency
ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB-650C2-B immediately
switches to the emergency mode and operates one of the existing
lamps for 90 minutes. When the power is restored the unit automatically
goes into recharge mode and features a time delay to prevent false tripping
at lamp end of life. The unit contains an internal long life maintenance
free Nickel Cadmium battery, charger, and electronic inverter
circuit in a compact metal case. The EB-650C2-B can be used with most
18 & 26 Watt quad tube 2-PIN LAMPS with an initial output of up to
650 lumens. The EB-650C2-B has leads and is designed to be hard wired
into the fixture enclosure or wireway.

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 650 lumens
For indoor appications.
AC input power rating: 2.5 Watts
Charging indicator light: LED.

Lamps operated: most 18W and 26W quad tube CF


2-PIN lamps with integral starter
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 2.2 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

18W PL CF 2-PIN

550

26W PL CF 2-PIN

650

The EB-650C2-B-A does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB650C2-B is warranted for a period of 3 years from the date of purchase. This warranty covers only properly
installed emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or
replace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our
inspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's
exclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Emergency
Ballast

EMERGENCY BALLASTS FOR


COMPACT FLUORESCENT LAMPS
EB-650C4-A Compact Fluorescent Emergency Ballast650 Lumens

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 650 lumens
2 lamps up to 325 lumens.
AC input power rating: 2.5 Watts
Charging indicator light: LED.

Lamps operated: 1 lamp 10W-42W or 2 lamp 10W-26W CF 4-PIN


lamps, twin, quad or triple 2D and 18-36W Long Compact.
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 3.2 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

2 lamp

13W PL CF 4-PIN

350

400

18W PL CF 4-PIN

350

550

26W PL CF 4-PIN

425

650

32W PL CF 4-PIN

600

42W PL CF 4-PIN

750

18W Long CF-PIN

500

18W Long CF-PIN

650

The EB-650C4-A does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB650C4-A is warranted for a period of 3 years from the date of purchase. This warranty covers only properly
installed emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or
replace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our
inspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's
exclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

EmergencyBallasts

The Etlin-Daniels EB-650C4-A is a UL listed fluorescent lamp emergency


ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB650C4-A immediately
switches to the emergency mode and operates one of the existing
lamps for 90 minutes. When the power is restored the unit automatically
goes into recharge mode and features a time delay to prevent false tripping
at lamp end of life. The unit contains an internal long life maintenance
free Nickel Cadmium battery, charger, and electronic inverter
circuit in a compact metal case. The EB-650C4-A can be used with most
10 & 42 Watt triple, quad, twin tube 18 to 36W long tube CF 4-PIN
LAMPS with an initial output of up to 650 lumens. The EB-650C4-A
provides dual 3/8" flexible conduits, one for the fixture or ballast compartment
and the other to the switch box which includes the test switch,
charge light, and unit battery connector.

A60

Emergency
Ballast

EmergencyBallasts

A61

EMERGENCY BALLASTS FOR


COMPACT FLUORESCENT LAMPS

EB-650C4-B Compact Fluorescent Emergency Ballast650 Lumens


The Etlin-Daniels EB650C4-B is a UL listed fluorescent lamp emergency
ballast that allows the same fixture to be used for both normal
and emergency modes. When the AC power fails the EB650C4-B
immediately switches to the emergency mode and operates one of the
existing lamps for 90 minutes. When the power is restored the unit
automatically goes into recharge mode and features a time delay to
prevent false tripping at lamp end of life. The unit contains an internal
long life maintenance free Nickel Cadmium battery, charger, and electronic
inverter circuit in a compact metal case. The EB-650C4-B can
be used with most 13 & 42 Watt triple, quad, twin tube 18 to 36W
long tube CF 4-PIN LAMPS with an initial output of up to 650 lumens.
The EB650C4-B provides dual 3/8" flexible conduits, one for
the fixture or ballast compartment and the other to the switch box
which includes the test switch, charge light, and unit battery connector.

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 650 lumens
2 lamps up to 325 lumens.
AC input power rating: 2.5 Watts
Charging indicator light: LED.

Lamps operated: 1 lamp 13W-42W or 2 lamp 13W-26W CF 4PIN lamps, twin, quad or triple 2D and 18-36W Long Compact.
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 2.5 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

2 lamp

13W PL CF 4-PIN

350

400

18W PL CF 4-PIN

350

550

26W PL CF 4-PIN

425

650

32W PL CF 4-PIN

600

42W PL CF 4-PIN

750

18W Long CF-PIN

500

18W Long CF-PIN

650

The EB-650C4-B does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-650C4-B is warranted for a period of 3 years from the date of purchase. This warranty covers only properly
installed emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or
replace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our
inspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's
exclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Emergency
Ballast

EMERGENCY BALLASTS FOR


LINEAR FLUORESCENT LAMPS
EB-700 Linear Fluorescent Emergency Ballast700 Lumens

A62

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 700 lumens
For indoor appications.
AC input power rating: 2.3 Watts
Charging indicator light: LED.

Lamps operated: most 2 to 4 single T8-T12, U-bend


or circline, rapid or instant start.
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 2.3 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

F17T8

450

F32T8

700

F20T12

390

F40T12

660

F20T12 Circline

625

F40T12 Circline

650

The EB-700 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-700 is warranted for a period of 3 years from the date of purchase. This warranty covers only properly installed
emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or replace
without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our inspection
determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's exclusive
warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

EmergencyBallasts

The Etlin-Daniels EB-700 is a UL listed fluorescent lamp emergency


ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB-700 immediately
switches to the emergency mode and operates one of the existing lamps
for 90 minutes. When the power is restored the unit automatically goes
into recharge mode and features a time delay to prevent false tripping at
lamp end of life. The unit contains an internal long life maintenance free
Nickel Cadmium battery, charger, and electronic inverter circuit in a
compact metal case.

Emergency
Ballast

EmergencyBallasts

A63

EMERGENCY BALLASTS FOR


LINEAR FLUORESCENT LAMPS

EB-700-2 Linear Fluorescent Emergency Ballast700 Lumens


The Etlin-Daniels EB-700-2 is a UL listed fluorescent lamp emergency
ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB-700-2 immediately
switches to the emergency mode and operates one of the existing lamps
for 90 minutes. When the power is restored the unit automatically goes
into recharge mode and features a time delay to prevent false tripping at
lamp end of life. The unit contains an internal long life maintenance free
Nickel Cadmium battery, charger, and electronic inverter circuit in a
compact metal case.

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 700 lumens
2 lamps 350 lumens each lamp
For indoor appications.
AC input power rating: 2.3 Watts
Charging indicator light: LED.

Lamps operated: most 2 to 8 single or 2 x 2 to 4


bipin, T8-T12, HO, VHO U bend or circline, rapid or
instant start
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 2.1 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

2 lamp

F17T8

450

650

F32T8

700

675

8 T8 FO96 or 59W

675

F20T12

390

650
650

F40T12

660

8 T12 F96T12 60W

650

40W Biax

600

55W Biax

650

F40T12 Circline

650

The EB-700-2 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-700-2 is warranted for a period of 3 years from the date of purchase. This warranty covers only properly
installed emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or
replace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our
inspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's
exclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Emergency
Ballast

EMERGENCY BALLASTS FOR


LINEAR FLUORESCENT LAMPS
EB-1300 Linear Fluorescent Emergency Ballast1300 Lumens

A64

Features and Benefits:


Dual input voltage: 120/277V, 60Hz
Operating temp: 0C to 55C
Illumination time: 90 minutes
Initial illumination: 1 lamp up to 1300 lumens
2 lamps 650 lumens each lamp
For indoor appications.
AC input power rating: 2.9 Watts
Charging indicator light: LED.

Lamps operated: most 2 to 8 single or 2 x 2 to 4


bipin, T8-T12, HO, VHO U bend or circline, rapid or
instant start.
Warranty: 3 years (see note below)
Test Switch: included Open Circuit isolation
Weight: 3.1 lbs
Approvals: UL

Average Lumen Rating of Lamps:

Case Style & Dimension:

Lamp type and wattag

1 lamp

2 lamp

F17T8

1125

1100

F32T8

1350

1350

8 T8 FO96 or 59W

1300

F20T12

680

F40T12

1150

8 T12 F96T12 60W

1125

40W Biax

1050

55W Biax

1100

F40T12 Circline

1125

The EB-1300 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If a
switched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast must
be fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannot
exceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50
feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-1300 is warranted for a period of 3 years from the date of purchase. This warranty covers only properly
installed emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or
replace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our
inspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's
exclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minute
requirements.

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

EmergencyBallasts

The Etlin-Daniels EB-1300 is a UL listed fluorescent lamp emergency


ballast that allows the same fixture to be used for both normal and
emergency modes. When the AC power fails the EB-1300 immediately
switches to the emergency mode and operates one of the existing lamps
for 90 minutes. When the power is restored the unit automatically goes
into recharge mode and features a time delay to prevent false tripping at
lamp end of life. The unit contains an internal long life maintenance free
Nickel Cadmium battery, charger, and electronic inverter circuit in a
compact metal case.

SECTION A
1850 Wilson Avenue, Toronto,
Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104
www.etlin.com

BALLASTS

APPENDIX &
SUFFIX GUIDE

A65

APPENDIX & SUFFIX GUIDE


Elecrtronic Ballasts
Ballast Disconnect
Magnetic Ballasts
Emergency Ballasts
Appendix: Wiring Diagrams & Case Styles
Appendix: Electonic Ballasts: Standard Lead Lengths & Standard Packaging
Appendix: Wiring Diagrams & Case StylesSuffix Guide

Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation.
While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,
no warranty is given in respect thereof and the company shall not be liable for any error herein.
Copyright 2011 Etlin-Daniels

A1-A41
A42-A43
A44-A55
A56-A64
A65-A73
A74-A79
A80

Appendix
WIRING DIAGRAMS

Case Styles and Dimensions

A66
DIMENSION IN INCHES

CASE

STYLE
1
2
3
4
1
2
3
4
1
2
3
4
6
7
1
2
3

4
5
6
7
8
9
10

1
2

3
4
1
2
3
4
1
1
2

(M)

(L)

WIDTH
(W)

HEIGHT
(H)

2.00
2.50
2.80
2.00
2.50
2.75
2.00
2.75
6.00
9.00
3.75
9.00
6.00
2.75
8.00
11.00
4.33
9.00
2.80
3.15
9.00
11
13.75
18.63
--------6.00
6.00
-5.37

2.36
3.11
3.27
2.36
2.75
3.15
2.36
3.15
6.61
9.49
4.02
9.49
6.46
3.10
6.46
11.65
4.76
9.45
3.15
3.45
9.49
11.70
14.31
19.19
1.89
1.61
1.54
1.77
2.48
2.28
2.68
2.09
6.46
6.46
2.48
5.50

1.10
1.85
1.54
1.18
1.50
1.73
1.41
1.50
2.36
2.40
1.93
2.28
1.89
1.89
1.089
3.15
2.17
3.15
1.48
1.80
1.65
3.15
3.19
3.19
2.26
1.97
2.00
1.89
1.48
1.30
1.30
1.30
1.89
1.89
1.89
1.89

1.42
1.34
1.97
1.42
1.20
1.30
1.40
1.30
1.57
1.61
1.50
1.57
0.96
1.43
1.42
1.85
1.57
1.85
1.14
1.20
1.15
2.50
2.60
2.63
2.99
2.36
2.87
2.56
1.06
0.79
0.79
0.79
0.98
1.42
1.34
1.75

Case A

Case B

Case C

Case D

Case E

Case F

Case G

Case J

Case K

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

A
A
A
A
B
B
B
B
C
C
C
C
C
C
D
D
D
D
D
D
D
D
D
D
E
E
E
E
F
F
F
F
J
G
G
K

LENGTH

Appendix
CASE STYLES

A67

Case Styles and Dimensions

Appendix

CASE
STYLE
L1
L2
L3
L4
L5
L6
L7
L8
M1
N1
N2
N3
P1
P2

DIMENSION IN INCHES
LENGTH
WIDTH
(W)
(M)
(L)
6.00
6.00
8.90
8.90
8.90
8.90
6.00
3.60
6.00
8.75
7.25
9.00
8.75
7.25

6.46
6.46
9.45
9.45
9.50
9.50
6.46
4.00
6.46
9.00
7.50
9.60
9.00
7.50

1.89
1.89
1.80
1.15
1.70
1.38
1.37
1.87
1.37
0.95
0.95
1.16
0.95
0.95

CASE
STYLE

HEIGHT
(H)
1.00
1.15
1.37
1.26
1.15
1.18
1.00
1.18
1.00
0.95
0.95
0.88
0.95
0.95

S1
S2
T1
T2
U1
U2
U3
U4
V1
W1
W2
X1
Y1
Z1

DIMENSION IN INCHES
LENGTH
WIDTH
(W)
(M)
(L)
3.12
3.12
4.63
4.63
14.00
6.00
8.75
16.34
5.60
4.63
4.63
2.80
0.90
2.0

3.45
3.45
5.0
5.0
14.40
6.46
9.00
16.7
5.90
5.0
5.0
3.07
-2.48

HEIGHT
(H)

1.81
2.91
2.40
3.00
1.23
1.28
0.95
1.18
0.91
2.40
3.00
1.16
1.54
1.38

Case L

Case M

Case N

Case P

Case S

Case T

Case U

Case X

Case V

Case Y

1.21
1.21
1.00
1.38
1.03
0.95
0.95
1.00
0.76
1.00
1.38
1.00
0.97
0.83

Case W

Case Z
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix
CASE STYLES

Case Styles and Dimensions

A68

Dimension in inches

Leads or Term Blk

Figure

Wired from

AA1

11.8

2.15

1.61

11

SIDE WIRE

FIG. 11 (NEXT PAGE)

AA2

11.5

1.34

1.06

11.14

TOP TERM BLK

FIG. 1

AA3

9.5

2.32

1.46

8.9

SIDE WIRE

FIG. 2

AA4

12.8

1.34

1.14

12.5

TOP TERM BLK

FIG. 1

AA5

17.71

1.7

1.14

17.24

TOP TERM BLK

FIG. 1

AA6

12.8

1.34

1.14

12.5

TOP TERM BLK

FIG. 1

AA15

5.36

2.48

1.18

4.84

SIDE TERM BLK

FIG. 4

AA16

5.36

2.48

1.18

4.84

BOTTOM STUD

FIG. 5

AA16

5.2

2.48

1.18

4.84

BOTTOM STUD

FIG. 5

AA17

4.9

2.5

1.14

4.48

BOTTOM FEED NO STUD

FIG. 3

AA23

6.5

1.9

1.14

5.9

BOTTOM STUD

FIG. 5

AA24

2.48

1.18

4.4

BOTTOM STUD

FIG. 5

AA18

4.9

2.5

1.14

4.48

BOTTOM STUD

FIG. 5

AA19

6.55

2.9

1.18

5.9

SIDE TERM BLKA

FIG. 4

AA20

6.55

2.9

1.18

5.9

BOTTOM STUD

FIG. 5

AA21

1.34

4.6

BOTTOM STUD

FIG. 3

AA22

17.71

1.7

1.14

17.24

SIDE WIRE

FIG. 6

AA25

7.8

3.1

1.4

7.3

BOTTOM STUD

FIG. 8

AA26

7.8

3.1

1.4

7.3

SIDE TERM BLK

FIG. 4

AA27

9.5

2.3

1.57

8.9

SIDE WIRE

FIG. 7

AA28

17.71

1.7

1.14

17.24

SIDE WIRE

FIG. 1

AA29

9.5

2.32

1.46

8.9

SIDE WIRE

AB1

4.11

1.38

1.10

3.62

FIG. 10 (NEXT PAGE)

AC1

4.17

--

1.87

1.06

FIG. 11 (NEXT PAGE)

FIG. 1

FIG. 5

FIG. 2

FIG. 6

FIG. 9 (NEXT PAGE)

FIG. 3

FIG. 4

FIG. 7

FIG. 8

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

OUR No.

Appendix
CASE STYLES AND WIRINGDIAGRAMS

Appendix

A69

Case Styles and Dimensions

FIG. 9

FIG. 10

FIG. 11

FIG. 1

FIG. 2

FIG. 3

FIG. 4

FIG. 5

FIG. 6

FIG. 7

FIG. 8

FIG. 9

Wiring Diagrams Fig. 1-9

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix
WIRINGDIAGRAMS

Wiring Diagrams Fig. 10-24

FIG. 11

FIG. 12

FIG. 13

FIG. 14

FIG. 15

FIG. 16

FIG. 17

FIG. 19

FIG. 20

FIG. 21

FIG. 22

FIG. 23

FIG. 24

FIG. 18

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

FIG. 10

A70

Appendix
WIRING DIAGRAMS

Appendix

A71

Wiring Diagrams Fig. 25-36

FIG. 25

FIG. 26

FIG. 27

FIG. 28

FIG. 29

FIG. 31

FIG. 32

FIG. 33

FIG. 34

FIG. 35

FIG. 36

FIG. 30

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix
WIRINGDIAGRAMS

Wiring Diagrams Fig. 37-48

A72

FIG. 38

FIG. 39

FIG. 40

FIG. 41

FIG. 43

FIG. 44

FIG. 45

FIG. 46

FIG. 47

FIG. 48

FIG. 42

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

FIG. 37

A_Ballastspgs65-80_HID Ballasts.qxd 12-04-16 10:03 AM Page 9

Appendix
WIRING DIAGRAMS

Appendix

A73

Wiring Diagrams Fig. 49-58

FIG. 49

FIG. 50

FIG. 51

FIG. 52

FIG. 53

FIG. 54

FIG. 55

FIG. 56

FIG. 57

FIG. 60

FIG. 58

FIG. 59

FIG. 61

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix
ELECTRONIC BALLASTS - STANDARD
LEAD LENGTH
Energy Saving (ES) Series
CAT. NO.

A74
RED

YELLOW

BLUE

WHITE

BLACK

Standard

34 x 34

---

26 X 26

22

22

Standard

26 X 26

37 X 37

26 X 26

22

22

Standard

48

---

48

72

72

ES-196-*-TP

Standard

---

---

48

72

72

ES-296-2-TP

Standard

48

72 X 72

48

72

72

ES-196HO-*-TP

Standard

48 X 48

---

72 X 72

22

22

ES-296HO-*-TP

Standard

48 X 48

72 X 72

48 X 48

22

22

ES-140-*-TP
ES-240-*-TP
ES-232-*-TP
LW-240-1-TP
LE-240-1-TP
ES-296-1-TP
ES-275-1-TP

Normal Power Factor (N) Series


CAT. NO.

OPTION

RED

YELLOW

BLUE

WHITE

BLACK

N-140-1-TP

Standard
Style 1

32 x32
30 x30

-----

19
30

30
30

14
14

N-120-1-TP

Standard
Style 1

16 x 16
15 x 15

-----

20
18

19
24

12
12

N-240-1-TP
N-234-1-TP

Standard

12 X 12

36 X 36

12 X 12

18

18

N-220-1-TP

Standard

15 X 15

23 X 23

15 x 15

12

12

N-113A-1-TP

Standard

---

---

16

16

16

N-113-1-TP-IES

Standard

16 X 16

16

---

---

16

N-213-1-TP-IES

Standard

16 X 16

16 X 16

16 X 16

---

16

All ballast for circline


with socket

Standard

12

12

Socket Assembles are 9 from the side


of the ballast case

Compact Fluorescent (CF) Series


CAT. NO.
CF-1322 Series
CF-1320S Series
CF-1322M Series
CF-49 and CF-570 Series

OPTION

BLACK

Standard
Style 1
Style 2
Style 3

9 x 18
7 x 15
6 x 12
12 x 12

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

OPTION

APPENDIX

ELECTRONIC BALLASTS - STANDARD


LEAD LENGTH

Energy Ballast (EB) Series


A75
CAT. NO.

OPTION

BLUE

YELLOW

RED

WHITE

BLACK

Appendix

T5 Straight Lamp
EB-113-1-TP
EB-113-1-TP-MC
EB-113-1-TP-SL
EB-113-1-TP-SL-MC
EB-113-1-TP-SLL
EB-113-1-TP-SLL-MC
EB-208-1-TP
EB-208-1-TP-MC
EB-208-1-TP-SL
EB-208-1-TP-SL-MC

18 x 18

---

18 x 18

18

18

EB-213-1-TP
EB-213-1-TP-MC
EB-213-1-TP-SL
EB-213-1-TP-SL-MC

24

---

24

18

18

T8 Straight Lamp
EB-132-1-TP-PIC
EB-132-UV-TP-PIC

32

---

48

20

20

EB-2C72-1-TP
EB-132-UV-TP-SL
EB-232-UV-TP-SL

32 x 32

---

48 x 48

20

20

32 x 32

---

48

20

20

32 x 32 x 32

---

48

20

20

32 x 32

48 x 48

32 x 32

20

20

12

12

12

12

18

12

12

EB-232-1-TP-PIC
EB-232-UV-TP-PIC
EB-232SL-1-TP
EB-232SL-2-TP
EB-232SL-3-TP
EB-232RIS-1-TP
EB-332-1-TP-PIC
EB-332-UV-TP-PIC
EB-332-1-TP
EB-332-2-TP
EB-432-1-TP-PIC
EB-432-UV-TP-PIC
EB-432-1-TP
EB-432-2-TP
EB-432RIS-1-TP

Compact Lamp
EB-113-1-TP-PN
EB-1C22-1-TP
EB-1C22-1-TP-LC
EB-126-1-TP
EB-218-1-TP
EB-226-1-TP

---

Circline Lamp
EB-1C22-1-TP-WS
EB-1C22-1-TP-WS-LC
EB-1C3032-1-TP-WS

---

EB-1C3032-1-TP-WS-LC

EB-2C72-1-TP-WS

2D Lamp
EB-1382D-1-TP

18

---

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

APPENDIX
ELECTRONIC BALLASTS - STANDARD
PACKAGING
Models with 9 inch Long Can

A76

ES-140 Series, ES-140N Series, ES-240 Series, ES-240N Series, ES-232 Series
20 Container

Pallet Information

CARTON

STYLE
PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

BULK PACK

11500

23

500

---

107 X 90 X 41

765

---

---

10 PCS PACK

11500

22

540

54

107 X 90 X 51

825

10

37 X 26 X 9

IND. BOXED

11500

24

450

48

107 X 90 X 63

735

10

42 X 26 X 10

Models with 11 inch Long Can

ES-296-1-TP, ES-296N-1-TP, ES-296-2-TP, ES-275-1-TP


20 Container

Pallet Information

CARTON

STYLE
QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

BULK PACK

5184

18

288

---

107 X 90 X 41

1037

---

---

6 PCS PACK

5148

22

234

39

107 X 90 X 41

845

36 X 31 X 10

IND. BOXED

5184

18

288

48

107 X 90 X 63

1037

36 X 31 X 10

ES-196HO-*-TP ES-296HO-*-TP
20 Container

Pallet Information

CARTON

STYLE
QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

BULK PACK

3780

21

180

---

107 X 90 X 41

858

---

---

4 PCS PACK

3872

22

176

44

107 X 90 X 41

863

30 x 20 x 15

IND. BOXED

3872

22

176

44

107 X 90 X 63

840

31.5 x 21.5 x 16.5

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

QTY / pcs

APPENDIX
ELECTRONIC BALLASTS - STANDARD
PACKAGING
A77

Electronic Ballast (EB) Series


CARTON

Appendix

CAT. NO.

20" CONTAINER

PALLET

DIMENSIONS /
mm

NO. OF
UNIT

DIMENSIONS /
mm

NO. OF
CTN

NO. OF
UNIT

WEIGHT

NO. OF
PALLET

NO. OF
UNIT

EB-113-1-TP

370X245X205

40

1200X1000X950

48

1920

623

16

30720

EB-113-1-TP-MC

370X245X205

40

1200X1000X950

48

1920

657

16

30720

EB-113-1-TP-SL

370X245X205

50

1200X1000X950

48

2400

672

16

38400

EB-113-1-TP-SL-MC

370X245X205

50

1200X1000X950

48

2400

705

16

38400

EB-113-1-TP-SLL

370X245X205

50

1200X1000X950

48

2400

672

16

38400

EB-113-1-TP-SLL-MC

370X245X205

50

1200X1000X950

48

2400

705

16

38400

EB-113-1-TP-PN

470X265X210

100

1200X1000X970

32

3200

617

16

51200

EB-208-1-TP

370X245X205

40

1200X1000X950

48

1920

705

16

30720

EB-208-1-TP-MC

370X245X205

40

1200X1000X950

48

1920

730

16

30720

EB-208-1-TP-SL

370X245X205

50

1200X1000X950

48

2400

748

16

38400

EB-208-1-TP-SL-MC

370X245X205

50

1200X1000X950

48

2400

768

16

38400

EB-213-1-TP

370X245X205

40

1200X1000X950

48

1920

720

16

30720

EB-213-1-TP-MC

370X245X205

40

1200X1000X950

48

1920

748

16

30720

EB-213-1-TP-SL

370X245X205

50

1200X1000X950

48

2400

792

16

38400

EB-213-1-TP-SL-MC

370X245X205

50

1200X1000X950

48

2400

825

16

38400

EB-IC22-1-TP

470X265X210

100

1200X1000X970

32

3200

553

16

51200

EB-IC22-1-TP-WS

470X265X210

100

1200X1000X970

32

3200

570

16

51200

EB-IC22-1-TP-LC

330X270X210

48

1200X1000X960

48

2304

705

16

36864

EB-IC22-1-TP-WS-LC

330X270X210

48

1200X1000X960

48

2304

705

16

36864

EB-IC3032-1-TP-WS

470X265X210

100

1200X1000X970

32

3200

570

16

51200

EB-IC3032-1-TP-WS-LC

330X270X210

36

1200X1000X960

48

1728

576

16

27648

EB-2C72-1-TP

330X270X210

36

1200X1000X960

48

1728

680

16

27648

EB-2C72-1-TP-WS

330X270X210

36

1200X1000X960

48

1728

705

16

27648

EB-126-1-TP

470X265X210

100

1200X1000X970

32

3200

553

16

51200

EB-218-1-TP

330X270X210

36

1200X1000X960

48

1728

680

16

27648

EB-226-1-TP

330X270X210

36

1200X1000X960

48

1728

680

16

27648

EB-1382D-1-TP

470X265X210

100

1200X1000X970

32

3200

617

16

51200

370X245X205

35

1200X1000X950

48

1680

920

16

26880

370X245X205

30

1200X1000X950

48

1440

1160

15

21600

270X275X330

30

1120X960X760

20

600

520

28

16800

390X260X120

10

1100X950X600

49

490

590

30

14700

EB-132-UV-TP-SL
EB-232-UV-TP-SL
EB-132-1-TP-PIC
EB-232-1-TP-PIC
EB-332-1-TP-PIC
EB-432-1-TP-PIC
EB-132-UV-TP-PIC
EB-232-UV-TP-PIC
EB-332-UV-TP-PIC
EB-432-UV-TP-PIC
EB-232R-1-TP
EB-232R-2-TP
EB-232R-3-TP
EB-232SL-1-TP
EB-232SL-2-TP
EB-232SL-3-TP
EB-332-1-TP
EB-332-2-TP
EB-432-1-TP
EB-432-2-TP

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

APPENDIX
ELECTRONIC BALLASTS - STANDARD
PACKAGING
Models with 6 inch Long Can & CF Series

A78

N-120-1-TP, N-140-1-TP, NPF T8 Series, CF-118-1, CF-126-1 Series


STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

BULK PACK

19090

29

830

---

107 X 90 X 36

782

---

---

30 PCS PACK

19090

22

900

30

107 X 90 X 36

847

30

35 X 18 X 18

IND. BOXED

17856

24

744

93

107 X 90 X 51

703

19 X 14 X 18

STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

32400

24

1350

45

107 X 90 X 36

660

30

35 x 17 x 13

30 PCS PACK

N-220-1-TP, CF-218-1-HP-TP, CF-226-1-HP-TP


STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

BULK PACK

15600

24

650

---

107 X 90 X 40

743

---

---

30 PCS PACK

15600

20

780

39

107 X 90 X 51

888

20

35 x 18 x 16

N-240-1-TP, N234-1-TP
STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

19040

17

1120

---

90 x 70 x 31

1010

---

---

BULK PACK

CF-579 Series
STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

80640

14

5760

80

100 X 78 X 88

1080

72

38 X 24 X 9

72 PCS PACK

CF-1322 Series
STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

56000

14

4000

80

100 X 78 X 88

1255

50

38 X 24 X 9

50 PCS PACK

CF-1320S-CC Series
STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

67200

14

4800

60

100 X 78 X 88

1047

60

38 X 24 X 8.5

60 PCS PACK

CF-1320S-OC Series
STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

84000

14

6000

60

100 X 78 X 88

1125

60

38 X 17.5 X 8.5

60 PCS PACK

CF-13-HP-TP
STYLE
50 PCS PACK

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

42000

14

3000

60

100 X 78 X 88

1215

50

50 X 24 X 9

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Appendix

N-113-1-TP-IES, N-213-1-TP-IES, N-113A Series, N-117-1-TP, CF-118-1-TP

APPENDIX
ELECTRONIC BALLASTS - STANDARD
PACKAGING
A79

Circline Ballasts
CF-22-WS-TP
STYLE
48 PCS PACK

20 Container

Pallet Information

QTY / pcs

PALLET

QTY / pcs

CARTON

46080

24

1920

40

SIZE / cm

CARTON
WEIGHT /kgs

QTY / pcs

SIZE / cm

750

48

---

Appandix

N-122-1-TP-WS, N-140-1-TP-WS
STYLE

20 Container

Pallet Information

QTY / pcs

PALLET

QTY / pcs

BULK PACK

18260

22

20 PCS PACK

17600

22

IND. BOXED

17856

24

CARTON

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

830

---

107 X 90 X 36

810

---

---

800

40

107 X 90 X 40

762

20

48 X 20 X 8

744

93

107 X 90 X 51

729

19 X 14 X 18

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

N-2232-1-TP-WS
STYLE

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

SIZE / cm

BULK PACK

14950

23

650

---

107 X 90 X 41

762

---

---

10 PCS PACK

14700

21

700

70

107 X 90 X 41

815

10

30 X 21 X 8

IND. BOXED

16560

23

720

120

107 X 90 X 63

843

19 X 14 X 18

N-3240-1-TP-WS, ES-3240-1-TP-WS
STYLE
BULK PACK

20 Container

Pallet Information

CARTON

QTY / pcs

PALLET

QTY / pcs

CARTON

SIZE / cm

WEIGHT /kgs

QTY / pcs

SIZE / cm

14300

22

650

---

107 X 90 X 41

810

---

---

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Suffix Guide
SUFFIX GUIDE

Suffix Guide
INPUT LINE VOLTAGE
277V INPUT LINE VOLTAGE
347V INPUT LINE VOLTAGE
480V INPUT LINE VOLTAGE
Aluminum Primary Winding, Aluminum Secondary Winding
ADAPTER
ALUMINUM CASE
Copper Primary Winding, Aluminum Secondary Winding
CLAMP CORE
DOUBLE TAP INPUT VOLTAGE (120V, 277V)
DIMMABLE
DUAL WAY CONNECTOR
BF = 0.77
COMPLY WITH FCC CLASS B REQUIREMENT
ENCASED
FINGER CAN
BF = 1.88
HIGH POWER FACTOR
120V OUTPUT VOLTAGE
INTERNAL ELECTRONIC STARTER
INTERNATIONAL VOLTAGE (90V-240V)
BF = 0.88
LARGE CAN
LOCAL DIMMABLE
WITH LEAD WIRE
LOW HEAT
WITH MOUNTING CUP
OPEN CORE
5 TAP INPUT VOLTAGE (120V, 208V, 240V, 277V, 480V)
WITH SINGLE BLOW THERMAL FUSE
PLUG-IN
PLASTIC ENCASED
ACTIVE POWER FACTOR CORRECTION
PRE-HEAT START
PROGRAMMED START
PROGRAMMED START & DUAL WAY CONNECTOR
RECESSED JUNCTION BOX WITHOUT BOTTOM STUD
RECESSED JUNCTION BOX WITH BOTTOM STUD
QUAD TAP INPUT VOLTAGE (120V, 208V, 240V, 277V)
QUAD TAP INPUT VOLTAGE (120V, 208V, 240V, 347V)
SHORT CIRCUIT PROTECTION
SHORT CAN WITH BOTTOM STUDS
SHORT CAN WITHOUT BOTTOM STUDS
SLIM CAN
LONG SLIM CAN
SELF-START
CLASS P BALLAST
UNIVERSAL LINE INPUT VOLTAGE (120V-277V)
WITH CORD
WITH CIRCLINE SOCKET

Suffix Guide

-1
-2
-3
-4
-AA
-AD
-AL
-CA
-CC
-D
-DIM
-DW
-EBF
-EMI
-EN
-FC
-HBF
-HP
-HV
-IES
-IV
-LBF
-LC
-LDIM
-LS
-LH
-MC
-OC
-P
-PF
-PG
-PN
-PIC
-PH
-PS
-PSD
-RJ
-RJS
-Q
-Q3
-SCP
-SCS
-SC
-SL
-SLL
-SS
-TP
-UV
-WC
-WS

A80

FOR MORE INFORMATION CALL


1-800-661-9610 (Canada) 1-888-762-5384 (USA)

Potrebbero piacerti anche