Sei sulla pagina 1di 112

PE90460

Medium & Low Voltage Distribution


Modernisation of switchboards

TM

ECOFIT
Green is our colour
Catalogue 2013

ECOFIT

TM

Index
How to find an ECOFIT solution?
1. Select the " generic family "
(MV xxx, LV xxx or protection relay).
2. Select the " Panel type ".
3. Select the " Original device type ".

Original Brand

MV Panel LV CB or LV Drawer Protection Panel type


MV CB or
Contactor
relay
Contactor or
Disconnector

Original
device type

New device
type

Nuova Magrini
Galileo

NA

B Control

Masterpact NW

Merlin Gerin

NA

Compact
C801-C1251

Compact NS

Merlin Gerin

NA

DA

Masterpact NW

Square D

NA

DS

Masterpact NW

Federal Pioneer

NA

H series

Masterpact NT
- NW

Merlin Gerin

NA

Masterpact M

Masterpact NW

Square D,
Westinghouse

NA

SE

Masterpact NW

Merlin Gerin

NA

Selpact

Masterpact NT
- NW

Unelec-Areva

Normabloc 660 Unelec CNP

Masterpact NW

Merlin Gerin

NA

Visucompact
CM

Masterpact NW
MB400 drawers

Merlin Gerin

MB400

MB400
drawers

Merlin Gerin

T140

T140 drawers T140 drawers

Page

A-2
A-3
A-4
A-5
A-6
A-7
A-8
A-9
A-10
A-11
A-13
A-14

Square D

5-15 kV MC
switchgear

VAD2-3

Magnum CB

Concordia
Sprecher

All AEG
cubicles

TG

TG

Merlin Gerin

Belledonne
B200-B400

DSE22 to
DSE78

LF2 - LF3 - SF1


- Evolis

Merlin Gerin

Belledonne
B200G

DSE22KDSE23K

LF1 - Evolis

Merlin Gerin

Belledonne
B650

DIS

LF1 - R400 R400D - Evolis

Merlin Gerin

Belledonne
B900

DIS

SF1

AEI,
GEC Alsthom

BVP 17

BVP 17

VMX

CEM

CEMABLOCCB
C23mc 15 & 27

FP

CEM

CEMABLOCCB
C23mc 15 & 27

HVX

CEM

CEMAFLUOR- CS
C26.0

FPR

Merlin Gerin

Chamrousse

DIS

LF2 - R400 R400D

Nuova Magrini
Galileo

Composit

MG

SF1

VEB
Otto Buchwitz

CSIM 1-12

SCI-4

VEIVACUUM F

VEB Otto
Buchwitz

CSIM 3-12

SCI-4

VEIVACUUM F,
VA10031

AEG

D-12

BAL, VAA, VA VAA, VA

AEG

D-24

BAL, VAA

VAA

Alsthom

DNF4-2E

FP, GFA

FP, HVX, CVX

Alsthom

DNF4 MI&FI

FP

FP, HVX

Alsthom

DNF5/DNF52B

FP

FP, HVX

Alsthom

DNF6

FP

FP, HVX

Alsthom

DNF7

FP

FP, HVX-O2

Nuova Magrini
Galileo

Epoclad

DHF-F

LF1 - LF2 - LF3


- SF1

B-23

Merlin Gerin

Fluair
F100-F200

FG1-FG2

LF2 - LF3 Evolis

B-24

Merlin Gerin

Fluair F100C

R400-R400D

R400 - R400D

Merlin Gerin

Fluair F400C

FC4

SF2

Merlin Gerin

Fluair F400G

FG4

SF1 - SF2

Delle Alsthom

FLUOMATIC
F540

FR62

FP62

Delle Alsthom

FLUOMATIC
F943

FR62

BLV

AEG

GS-10

GE

VA - VAA

GEC Alstom

HMC 400 &


HMC 410

HMC 400 HMC 410

HMC 400 HMC 410

B-2
B-3
B-4
B-5
B-6
B-7
B-8
B-9
B-10
B-11
B-12
B-13
B-14
B-15
B-16
B-17
B-18
B-19
B-20
B-21
B-22

B-25
B-26
B-27
B-28
B-29
B-30
B-31

Original Brand

MV Panel LV CB or LV Drawer Protection Panel type


MV CB or
Contactor
relay
Contactor or
Disconnector

Original
device type

New device
type

GEC Alstom

HMC 1072

HMC 1072

HMC 1072

GEC Alstom

HMC 1172

HMC 1172

HMC 1172

GEC Alstom

HMX 36

HMX 36

HMX 36

CEM

KIT 25-PGDt

CC

FP

CEM

KIT 27.2-PGHt

HF4K

FP

AEG

D-E

HVX

Federal Pioneer

Metalclad
switchgear

DST 2 & 5

DST 2V & 5V

Merlin Gerin

Motorstart
P12D-P30D

KA-KDA

R400 - R400D

Page

B-32
B-33
B-34
B-35
B-36
B-37
B-38
B-39

Merlin Gerin

Motorstart
P50D

C-CD

R400 - R400D CTV1

B-40

Merlin Gerin

Motorstart
P500D

C1-CD1

R400 - R400D CTV1

B-41

GEC Alstom

MX 51 & MX
81

MX 51 - MX
81

MX 51 - MX 81

Delle Alsthom

NORMABLOC
N1347

HL

HVX - FPX

Delle Alsthom

NORMASEPT
N743

HL

FP

Concordia
Sprecher

PA, SC, SD

HP T/W/Z

HVX

AEG

E-M

VA - VAA

Ansaldo

Siclad

MAG II

LF2

Square D

Solenarc DSE
Metal-Clad
switchgear

DSE

Magnum CB

Taillefer
T900-T1080

DST

LF3

Nuova Magrini
Galileo

Venus

GI-GL

LF1-LF3

Merlin Gerin

VM6 DM12

FB4

SF1

Merlin Gerin

VM6 DM22DM23

FB4

SF1

GEC, GEC
Alstom, Alstom

VMX

VMX

VMX

AEG

WAK

D-E

HVX

AEG

WBA

VA, VAA,
ECA, BAL

VA, VAA

AEG

WBB

VA, VAA, ECA VA, VAA

AEG

WKC

VA, VAA, MC, FPX, VA, VAA


BAL

Yorkshire
Switchgear

YSF6

YSF6

YSF6 Evolis

AEG

D-12

D-12 panel

D-12 panel

AEG

D-24

D-24 panel

D-24 panel

Merlin Gerin

F100/200

F100/200
panel

F100/200 panel

Merlin Gerin

F100C

F100C panel

F100C panel

Alstom

PX 12-24

PX 12-24
panel

PX 12-24 panel

AEG

R panel

R panel

GEC, GEC
Alstom, Alstom

VMX

VMX panel

VMX panel

AEG

WBA

WBA panel

WBA panel

AEG

WBB

WBB panel

WBB panel

AEG

WKC

WKC panel

WKC panel

All

All

All

MiCOM Sepam

GEC Alstom,
Areva

All

KCGG 122
& 142

MiCOM P123R

Merlin Gerin

All

Sepam 2000

ECOFIT
Sepam 2000
ECOFIT
VIP11-12R

Merlin Gerin

RM6

B-43
B-44
B-45
B-46
B-47
B-48

Merlin Gerin

B-42

VIP11R &
VIP12R

B-49
B-50
B-51
B-52
B-53
B-54
B-55
B-56
B-57
B-58
B-60
B-61
B-62
B-63
B-64
B-65
B-66
B-67
B-68
B-69
C-2
C-3
C-4
C-5

* Not current ECOFIT reference centre

PE90457

TM

ECOFIT
Contents

ECOFITTM

Contents
Low Voltage Distribution

A-1

Medium Voltage Distribution

B-1

Protection relays

C-1

ECOFIT

TM
6

What does
that mean?

Schneider Electric is helping


you get the most of your
equipment and installations
Installation
Assessment

End-of-life

Services
Maintenance
contract

Installation &
Commissioning

Technical Training

Modernisation
On-demand
Maintenance

ECOFITTM is the economical


complement to maintenance
operations
It prolongs your switchgears lifetime.

"Green is our colour" - ECOFIT TM


is the most economical means of reducing your networks environmental
footprint without buying a whole new system
7

Presentation of the offer

Introduction

Today, the productivity, operating safety, continuity of service and availability requirements of installations
are such that at all levels of a company, the quest for high performance is a major consideration.

Taillefer, Fluair and Vercors cubicles and more than 3000 low-voltage retrofits on T140, T12 and
Masterbloc switchboards has enabled the Center to acquire the expertise and know-how required
to help you secure the loyalty of your customers.

p Supplying spare parts,


p Modifying cubicles,
p Replacing protective devices,
p Replacing original devices with latest-generation devices.

There are various ways of replacing old devices. The most usual methods are:

Retrofit: the original circuit breaker and its truck are replaced

p The connection interfaces (power and low voltage) are adapted for use on the original cubicle.
p The new circuit breaker is fitted with the new interfaces.
p The solution is tested mechanically with the mounting jig.

Retrofil: the original truck is retained and fitted with a new circuit breaker
p The original truck is renovated.
p The power interfaces are either retained and renovated or they are recreated.
p The new circuit breaker is adapted for mounting on the original truck.
p The solution is tested mechanically with the mounting jig.

solutions in order to provide you with constant support and help in ensuring customer satisfaction.
We pay particular attention to quality, which is our major consideration.

Presentation of the offer

Renovation solutions

Scope of the offer


Switchboard renovation
p Progressive replacement without modification of customers equipment:
renovation of medium and low voltage switchgear,
kits for improving equipment.
p Complete replacement or addition of cubicles by extension:
insertion of cubicles into the switchboard with connection ducts,
addition at the end of the switchboard of cubicles identical to the initial cubicle,
in accordance with floor space constraints.
Switchgear renovation
Replacement of old medium and low voltage switchgear and protection devices
by retrofit/retrofil solutions.
Supply of spare parts
Ensure the supply of spare parts for equipment that is no longer commercialized
by the equipment-producing departments.

Cost-effective solutions to fit your needs


p No break in continuity of service,
p No added civil engineering work,
p No modification of your equipment,
p Operating constraints taken into account,
p Progressive renovation to fit your budget.

Validated and tested solutions

p Manufacturers warranty on renovated equipment,


p Factory-validated and tested equipment.

New solutions

p Compliant with the standards in effect,


p Integration of new-generation products,
p Evolving device technology.

Presentation of the offer

Product life cycle

There are four major phases in the product life cycle:

Commercialization period
The product is launched on the market and is included in the Schneider Electric catalogue.
The supply of spare parts is guaranteed.

Guaranteed spare parts supply period


The product is withdrawn from the market.
Schneider Electric continues to supply spare parts for a limited period of time.
Generally speaking, the average guaranteed spare part supply period
after the end of commercialization is :
p medium voltage:
12 years
p low voltage power:
10 years
p compact (accessories - devices):
3 years
p electronic equipment:
according to the range
When the end of the guarantee period is reached, the product is considered to be expired.

Non-guaranteed spare parts supply period


As of the expiry date, the product is considered to be expired.
Spare part stock and supply are no longer guaranteed after the expiry date.
This period ends on the date on which the spare part offer is ended.
On that date, the stocks are entirely destroyed as well as the manufacturing tools.

Predicted end of
spare part offer

Expiry

Start of
commercialization

End of
commercialization

Prices and
delivery times

End of
commercialization

Spare parts
supply
guaranteed

Spare parts
supply
not guaranteed

Time

Switchgear retrofit

Device retrofit period


Commercialization of a retrofit offer for the replacement of old switchgear and protection devices.
The supply of retrofits will stop at the end of the commercialization of the new devices used.
The spare parts for these retrofits will therefore be handled as described above.

10

COFIT

TM

EOL

EOL,
the complementary
offer

12
12

11

End-of-life:
environment in mind!
In complement to ECOFIT, EOL proposal:
recovery and recycling for re-use of all
medium-voltage equipment, including SF6 gas
if applicable, metallic parts and accessories.

98%

of a medium-voltage cubicle can be recovered

 legal

SF6
environmental
a

requirement for the

, an

duty

1. Recovery of medium-voltage equipment from the customers site.


2. Dismantling of the equipment in a Schneider Electric factory. The different
ferrous and non-ferrous materials (copper, aluminium, etc.) are separated and
sent to specialised recycling centres.

3. When applicable, the SF6 is evacuated until the residual pressure is


EOL's
4 steps

less than 20 mbar, in accordance with the IEC standard, using adequate
engineered tools. The gas is stored in bottles before being sent for recycling.
The epoxy enclosure is crushed for recovery purposes.

4. A certificate of destruction compliant with the regulations is sent to


the customer.
12

PE56733

Benefit from
Schneider Electrics
image and know-how

14

Quality & Environment


Schneider Electric undertakes to reduce the
energy bill and CO2 emissions of its customers
by proposing products, solutions and services
which fit in with all levels of the energy value
chain.
At the same time, Schneider Electric strives
to reduce the environmental impact of
its products throughout their entire life-cycle
(from cradle to grave), particularly through
eco-design and eco-production.

13

Our common values :

Schneider Electrics policy has always been to provide


its customers with very close support in their daily
activities to enable them to achieve operational
excellence.

Quality
Safety
The experience of
Professionalism a world leader in Low & Medium
Voltage

5% of sales
devoted to R & D

Schneider Electric has been manufacturing LV and MV products for


more than 50 years and its installed base amounts to thousand millions
products and devices.
The Schneider Electric brand is known worldwide and recognized
by the most demanding customers.

Local support
all over the world.
There are always
Schneider Electric people
close to you:

6200 Services people


in more than

88 countries!
More than
23,000 ECOFITTM in
services/delivered
in various business segments

14

A long history of innovation


for a global offer
Based on this experience as world leader, Schneider Electric has
developed a large and comprehensive range of innovative devices.
With one of the world leaders, you take benefit of a global leader
experience and know-how in electric distribution, automation and Power
& control.
All the devices included in this overview have been designed
and manufactured to incorporate the benefits of this extensive
experience.

Schneider Electric
a brand you can trust

15

ECOFIT

PE90457

TM

Low Voltage
Distribution

ECOFITTM

Low Voltage Distribution

LV CB or Contactor
B Control

A-2

Compact C801-C1251

A-3

DA

A-4

DS

A-5

H series

A-6

Masterpact M

A-7

SE

A-8

Selpact

A-9

Unelec CNP

A-10

Visucompact CM

A-11

Associated offers Energy Management

A-12

Associated offers Source-changeover systems

A-12

LV Drawer
MB400

A-13

T140

A-14

Offer Extension Drawer components

A-15

A-1

LV CB or Contactor

Low Voltage Distribution

B Control
To give a new life to your installations
Original brand:
Nuova Magrini
Galileo
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

B Control

Masterpact NT/NW

Main technical characteristics


Rated Voltage Un (50/60 Hz)
220 V - 660 V
800 A to
4000 A
PE90573

B1-35 / B1-50

B2-50

(35 - 52 kA*)

(40 - 55 kA*)

B3-50 / B3-75 /
B3-90 (50 - 90 kA*)

B4-100
(50 - 100 kA*)
PE90573

Rated Current (Ir)


* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)


220 V - 660 V
800 A to
4000 A

Masterpact
NT/ NW

Masterpact NT / NW
(42 - 150 kA*)

(42 - 50 kA*)
PE90574

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1972

1990

2008
2009 ECOFIT

End
of life

Ongoing

Masterpact NT/NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\
A-2

p. A-12

LV CB or Contactor

Low Voltage Distribution

Compact C801-C1251
To give a new life to your installations
Original brand:
Merlin Gerin
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

C801 to C1251N/H

Compact NS

Main technical characteristics


C801 to C1251N/H
Rated Voltage Un (50/60 Hz)
220 V
800 A to
1250 A
PE90430

240 V

380 V

85 to 100 kA*

415 V

50 to 70 kA*

440 V

500 V

42 to
65 kA*

40 to
50 kA*

525 V

660 V

690 V
25 to
40 kA*
PE90430

PE90572

PE90431

059782N

Rated Current (Ir)


* Intensity short circuit (Isc)

Compact NS
Rated Voltage Un (50/60 Hz)
220 V
800 A to
1250 A

240 V

380 V

415 V

50 to 70 kA*

440 V
50 to
65 kA*

500 V

525 V

660 V

40 to 50 kA*

690 V

30 to 42 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1993

2007

2009

2009

ECOFIT

End
of life

Ongoing

Compact NS

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-12

A-3

LV CB or Contactor

Low Voltage Distribution

DA
To give a new life to your installations
Original brand:
Merlin Gerin
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

DSA1 / DNA1 / DSA2 / DNA2 / DRA / DNAH

Masterpact NW

Main technical characteristics


DSA1 / DNA1 / DSA2 / DNA2 / DRA / DNAH
Rated Voltage Un (50/60 Hz)
220 V

415 V

630 A to
6300 A

440 V

500 V

525 V

600 V
42 to
100 kA*

42 to 100 kA*

PE90424

660 V

690 V

42 to
85 kA*

Rated Current (Ir)

PE90424

* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V
800 A to
6300 A

415 V

440 V

500 V

525 V

600 V

42 to
130 kA*

42 to 150 kA*

660 V

690 V
42 to
100 kA*

630 A

PE90427

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1968

1986

2009

1997

ECOFIT

End
of life

Ongoing

Masterpact NW

Associated offers

A-4

Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-12

Source-changeover systems

p. A-12

LV CB or Contactor

Low Voltage Distribution

DS
To give a new life to your installations
Masterpact NW

Main technical characteristics


DS-206

PE90537

PE90536

DS

Rated Voltage Un (50/60 Hz)


690 V
42 kA*

800 A
Rated Current (Ir)
* Intensity short circuit (Isc)

Masterpact NW

PE90429

Original brand:
Square D,
Westinghouse
Version type:
draw-out or fixed

Rated Voltage Un (50/60 Hz)


690 V
42 kA*

800 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1983

1998

2013

2007

ECOFIT

End
of life

Ongoing

Masterpact NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-12

A-5

LV CB or Contactor

Low Voltage Distribution

H series circuit breaker


To give a new life to your installations
Original brand:
Federal Pioneer
Version type:
draw-out

H series

Masterpact NT/NW

Main technical characteristics


H series

H-3

HL-3

H-2

HL-2

100HF-1

Rated Voltage Un (50/60 Hz)


600 V
5000-6000 A

85 kA*

4000 A

85 kA*

85 kA* (1) 85 kA*

3200 A

75 kA*

75 kA* (1)

3000 A

50 - 75 kA*

65 kA* (1) 65 - 75 kA* 65 kA* (1)

2000 A

50 - 65 kA*

50 kA* (1) 50 - 65 kA* 65 kA* (1)

1600 A

42 - 50 - 65 kA*

50 kA* (1) 50 kA*

PE90615

(1)

800 A

30 - 42 - 50 kA*

30 kA*

600 A

30 - 42 - 50 kA*

30 kA* (1) 42 kA*

42 kA*

85 kA* (1)

50 kA* (1)
42 kA*

100 W Fuses
50 kA* (1)

(1)

42 kA* (1)

42 kA* (1)

PE90615

Rated Current (Ir)


* Intensity short circuit (Isc) - (1) 200 kA with fuse

Masterpact NT

Masterpact NW

Rated Voltage Un (50/60 Hz)


600 V
2500 A to 6000 A
N/A

1600 A to 2000 A

42 kA* - 50 kA* 85 kA* - 130 kA*

35 to 50 kA*

800 A to 1200 A

200 kA*
with fuse
(Cradle & Cradle only)
PE90616

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1960

2003

2013

2001

ECOFIT

End
of life

Ongoing

Masterpact NT-NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\
A-6

p. A-12

LV CB or Contactor

Low Voltage Distribution

Masterpact M
To give a new life to your installations
Original brand:
Merlin Gerin
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

M08 to M63

Masterpact NW

Main technical characteristics


M08 to M63
Rated Voltage Un (50/60 Hz)
220 V

035928

800 A to
6300 A

415 V

440 V

500 V

525 V

40 to 150 kA*

600 V

660 V

690 V

40 to 85 kA*

Rated Current (Ir)

035928

* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V
800 A to
6300 A

415 V

440 V

500 V

525 V

600 V

42 to
130 kA*

42 to 150 kA*

660 V

690 V
42 to
100 kA*
PE90429

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1986

2003

2006

2004

ECOFIT

End
of life

Ongoing

Masterpact NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-12

Source-changeover systems

p. A-12

A-7

LV CB or Contactor

Low Voltage Distribution

SE
To give a new life to your installations
Original brand:
Square D
Version type:
draw-out or fixed

SE

Masterpact NW

Main technical characteristics


SE

PE90538

Rated Voltage Un (50/60 Hz)


240 V

480 V

600 V

200 kA*

150 kA*

100 kA*

480 V

600 V

3000 A
800 A to
1250 A

PE90538

Rated Current (Ir)


* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
240 V
3000 A
100 kA*

800 A to
1250 A

85 kA*
PE90435

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1983

2003

2011

2010

ECOFIT

End
of life

Ongoing

Masterpact NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\
A-8

p. A-12

LV CB or Contactor

Low Voltage Distribution

Selpact
To give a new life to your installations
Original brand:
Merlin Gerin
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

DN2 / DS2 / DR2 / DRS2

Masterpact NW

Main technical characteristics


DN2 / DS2 / DR2 / DRS2
Rated Voltage Un (50/60 Hz)
220 V
PE90424

415 V

630 A to
6300 A

440 V

500 V

525 V

600 V
42 to
100 kA*

42 to 100 kA*

660 V

690 V

42 to
85 kA*

Rated Current (Ir)

PE90428

* Intensity short circuit (Isc)

Masterpact NT / NW
Rated Voltage Un (50/60 Hz)
220 V
630 A to
6300 A

415 V

440 V

500 V

525 V

600 V

42 to
130 kA*

42 to 150 kA*

660 V

690 V
42 to
100 kA*
PE90426

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1973

1989

2009

1997

ECOFIT

End
of life

Ongoing

Masterpact NT / NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-12

Source-changeover systems

p. A-12

A-9

LV CB or Contactor

Low Voltage Distribution

Unelec CNP
To give a new life to your installations
Original brand:
Unelec - Areva
Version type:
fixed device.
Only for
Normabloc 660
switchboard

CNP

Masterpact NW

Main technical characteristics


PE90432

CNP
Rated Voltage Un (50/60 Hz)
660 V
PE90432

36 to 100 kA*

1250 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90433

Masterpact NW
Rated Voltage Un (50/60 Hz)
690 V
42 to 100 kA*

1250 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1968

1986

2009

2007

ECOFIT

End
of life

Ongoing

Masterpact NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\
A-10

p. A-12

LV CB or Contactor

Low Voltage Distribution

Visucompact CM
To give a new life to your installations
Original brand:
Merlin Gerin
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Visucompact CM

Masterpact NW

Main technical characteristics


Visucompact CM
Rated Voltage Un (50/60 Hz)
220 V
PE90434

1250 A to
2500 A

240 V

380 V

85 kA*

415 V
70 kA*

440 V
65 kA*

Rated Current (Ir)

PE90434

* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V

240 V

1250 A to
2500 A

380 V

415 V

440 V

42 to 100 kA*
PE90435

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1985

2001

2005
2010 ECOFIT

End
of life

Ongoing

Masterpact NW

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-12

A-11

LV CB or Contactor

Low Voltage Distribution

Associated offers
Energy Management - Micrologic control units - Measurements and protections
Available
for ECOFIT
solutions using
Masterpact
NT/NW and
Compact NS
Micrologic

Type

A-E

A-E-P-H

A-E-P-H

7
A-P-H

Functions

Long time
+ instantaneous

Long time
+ short time
+ instantaneous

Long time
+ short time
+ instantaneous
+ earth fault

Long time
+ short time
+ instantaneous
+ earth leakage up to 3200A

A: Current measurements, fault indications, display and current maximeter.


E: A + Instantaneous measurement of power and energy without earth leakage protection.
P: A + Calculation of power and energy value, voltage measurement, and programmable protection
H: P + Harmonics

Energy Management - Communication


Available
for ECOFIT
solutions using
Masterpact
NT/NW and
Compact NS

,GHQWLI\WKHGHYLFH
,QGLFDWHVWDWXVFRQGLWLRQV
&RQWUROWKHGHYLFH
ZLWKWKHFRPPXQLFDWLQJDX[LOLDLULHV 
6HWWLQJRIWKHSURWHFWLRQDQGDODUPVIXQFWLRQV

1
24 V DC

7
1

Modbus network

&&0&KDVVLV
&RPPXQLFDWLRQ0RGXOH

2
8

%UHDNHU8QLYHUVDO/RJLF
Plug (ULP) cord

Breaker &RPPXQLFDWLRQ
0RGXOH %&0

Prefabricated wiring

Micrologic trip unit

)'0GLVSOD\

Line terminator

&RPSDFW16
or Masterpact
1TRU1:
depending on
WKHGHYLFH

5
4

Source-changeover systems
Available for
DA, Selpact and
Masterpact M
ECOFIT
solutions using
Masterpact
NT/NW

A-12

Mechanical interlocking (2 types)

Automatic controllers

Using connecting rods or using


cables

IVE: Electrical interlocking

BA or UA automatic controllers

LV Drawer

Low Voltage Distribution

MB400
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
drawers
compatible
with MB400 LV
switchboards

MB400 drawers

MB400 drawers

for distribution
& motor feeders

for distribution
& motor feeders

Main technical characteristics


MB400 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
PE90689

500 A
250 A

From 1 to 6 modules manually or electrically operated

125 A

PE90685

Rated Current (Ir)

MB400 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
500 A
250 A

From 1 to 6 modules manually or electrically operated

125 A
Rated Current (Ir)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1991

2003

2013

2003

ECOFIT

End
of life

Ongoing

MB400 drawers
by Services

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\

p. A-15

A-13

LV Drawer

Low Voltage Distribution

T140
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
drawers
compatible with
T140
LV switchboards

T140 drawers

T140 drawers

for distribution
& motor feeders

for distribution
& motor feeders

Main technical characteristics


T140 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
PE90687

500 A
250 A

From 1 to 6 modules manually or electrically operated

125 A

PE90685

Rated Current (Ir)

T140 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
500 A
250 A

From 1 to 6 modules manually or electrically operated

125 A

PE90685

Rated Current (Ir)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1975

1990

1998

1998

ECOFIT

End
of life

Ongoing

T140 drawers
by Services

Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a
C][[c\WQObW]\
A-14

p. A-15

Low Voltage Distribution

LV Drawer
Associated offers

Specific spare parts:


Available
for ECOFIT
solutions using
Masterpact
NT/NW and
Compact NS

Drawer components
3ZSQb`WQOZRWab`WPcbW]\Fc\QbW]\OZc\Wba<SX rO\US

Micrologic

2.2 or 2.3

Type
Functions

LSI protection

5.2 or 5.3

6.2 or 6.3

A-E

A-E

LSI protection
Ammeter
Energy meter

LSI protection
Ammeter
Energy meter

A: Current measurements, fault indications, display and current maximeter


(residual or Source Ground Return); 7.0 provides earth leakage protection.
E: A + Instantaneous measurement of power and energy without earth leakage protection.

;otor co\tr]ZQ][[O\RO\R^rotSQbW]\aFc\QbW]\OZc\Wba
1 component motor feeder

2 components motor feeder

3 components motor feeder

Circuit breaker Contactor combination

Thermomagnetic circuit breaker +


Contactor

Thermomagnetic circuit breaker


or switch-disconnector fuse +
Contactor + Thermal protection

Co\tr]ZQ][[O\ROcfWZWO`WSaf]`OZZtg^Saof drawers
Miniature circuit-breaker
Protection auxiliary circuit

Auxiliary relays

Ground fault protection

Push buttons and lights

A-15

ECOFIT

PE90457

TM

Medium
Voltage
Distribution

ECOFITTM

Medium Voltage Distribution

MV CB or Contactor or Disconnector
5-15 kV MC switchgear
All AEG cubicles
Belledonne B200-B400
Belledonne B200G
Belledonne B650
Belledonne B900
BVP 17
CEMABLOC-C23mc 15 & 27
CEMABLOC-C23mc 15 & 27
CEMAFLUOR-C26.0
Chamrousse
Composit
CSIM 1-12
CSIM 3-12
D-12
D-24
DNF4-2E
DNF4 MI&FI
DNF5/DNF5-2B
DNF6
DNF7
Epoclad
Fluair F100-F200
Fluair F100C
Fluair F400C
Fluair F400G
FLUOMATIC F540
FLUOMATIC F943
GS-10
HMC 400 & HMC 410
HMC 1072
HMC 1172
HMX 36
KIT 25-PGDt
KIT 27.2-PGHt
L
Metalclad switchgear
Motorstart P12D-P30D
Motorstart P50D
Motorstart P500D
MX 51 & MX 81
NORMABLOC N1347
NORMASEPT N743
PA, SC, SD
R
Siclad
Solenarc DSE Metal-Clad switchgear
Taillefer T900-T1080
Venus
VM6 DM12
VM6 DM22-DM23
VMX
WAK
WBA
WBB
WKC
YSF6

B-2
B-3
B-4
B-5
B-6
B-7
B-8
B-9
B-10
B-11
B-12
B-13
B-14
B-15
B-16
B-17
B-18
B-19
B-20
B-21
B-22
B-23
B-24
B-25
B-26
B-27
B-28
B-29
B-30
B-31
B-32
B-33
B-34
B-35
B-36
B-37
B-38
B-39
B-40
B-41
B-42
B-43
B-44
B-45
B-46
B-47
B-48
B-49
B-50
B-51
B-52
B-53
B-54
B-55
B-56
B-57
B-58

D-12
D-24
F100/200
F100C
PX 12-24
R
VMX
WBA
WBB
WKC

B-60
B-61
B-62
B-63
B-64
B-65
B-66
B-67
B-68
B-69

MV Panel

B-1

MV CB or Contactor or Disconnector

Medium Voltage Distribution

5-15 kV Metal-Clad Switchgear


To give a new life to your installations
Original brand:
Square D
Version type:
draw-out

VAD2
VAD3

Magnum CB (Vacuum)

Rated Voltage Un (50/60 Hz)


5 kV

15 kV

PE90543

Main technical characteristics

3000 A
2000 A
1200 A

VAD2 (29 kA*)


VAD3 (41 kA*)

VAD2 (18 - 28 kA*)


VAD3 (37 kA*)

Rated Current (Ir)


PE90542

Rated Voltage Un (50/60 Hz)


5 kV

15 kV

PE90544

* Intensity short circuit (Isc)

3000 A
2000 A

15SSB (18 - 28 kA*)


15SSB (37 kA*)

5SSB (29 - 41 kA*)

1200 A
Rated Current (Ir)
* Intensity short circuit (Isc)

Magnum CB main
characteristics

B-2

Commercialisation

End of
commercialisation

End of
spare parts

< 1985

1995

2006

ECOFIT

2004

End
of life

Ongoing

PE90437

Offer extension

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90461

Built with totally new


components and tested to
ANSI standards,
Magnum circuit breakers
correctly interface with
the existing breaker
compartment components
and maintain safety
interlocks inherent
in the original equipment
design.
s New circuit breakers
are installed in existing
switchgear.
s Original footprint is left
intact, saving time and
money.
s Installation expense is
a fraction of new
equipment costs.
- Less down time for
installation.
- Enhanced equipment
reliability.
s Manufactured with new
components.
s Undergoes complete
factory testing.
s Backed by our standard
equipment warranty.
s New, easy-to-maintain
operating mechanism.
s No bulky arc chutes
to handle and maintain.
s Reduced need for difficult
to obtain spare parts.

A true extended life time

Sepam series 10 - 20 - 40 - 60 - 80

Magnum CB

MV CB or Contactor or Disconnector

Medium Voltage Distribution

All AEG cubicles


To give a new life to your installations
TG

TG

Main technical characteristics


Rated Voltage Un (50/60 Hz)
12 kV

24 kV

15 to 63 kA*

16 to 31.5 kA*

36 kV

PE90656

TG

2500 A to 6300 A
630 A to 2500 A

19 to 31.5 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

TG
Rated Voltage Un (50/60 Hz)
12 kV

24 kV

15 to 63 kA*

16 to 31.5 kA*

36 kV

2500 A to 6300 A
630 A to 2500 A

PE90656

PE90656

Original brand:
Concordia
Sprecher
Version type:
disconnector
compatible with
all AEG cubicles

19 to 31.5 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1975

2006

Ongoing

2006

ECOFIT

End
of life

Ongoing

TG by Services

B-3

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Belledonne B200-B400
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Belledonne B200/
B400 cubicles

DSE22
to
DSE78

LF2 (SF6), LF3 (SF6)


SF1 (SF6)
Evolis (Vacuum)

Main technical characteristics


DSE22 to DSE78
7.2 kV

PE90402

PE90400

Rated Voltage Un (50/60 Hz)


12 kV

17.5 kV

24 kV

24 to 48 kA*

15 to 46 kA*

10 to 29 kA*

17.5 kV

24 kV

3500 A
3150 A
29 to 50 kA*

3000 A
1250 A
630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

7.2 kV

12 kV

PE90401

Rated Voltage Un (50/60 Hz)

3500 A
3150 A

LF2/LF3

LF2/LF3

(29 to 40 kA*)

3000 A

(29 to 50 kA*)

1250 A

Evolis

630 A

(40 kA* - 2500 A max)

Evolis
(40 kA*,
2500 A max)

SF1
(10 to 25 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1972

1986

2001

ECOFIT

1988

End
of life

Ongoing

PE90437

PE90400

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-4

LF2, LF3 or SF1


Evolis

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Belledonne B200G
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Belledonne
B200G
cubicles

DSE22K
DSE23K

LF1 (SF6)
Evolis (Vacuum)

Main technical characteristics


PE90405

PE90403

DSE22K to DSE23K
Rated Voltage Un (50/60 Hz)
7.2 kV
25 to 31.5 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90404

LF1 & Evolis


Rated Voltage Un (50/60 Hz)
7.2 kV
25 to 31.5 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1971

1988

1992

ECOFIT

1988

End
of life

Ongoing

LF1
Evolis

PE90437

PE90393

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-5

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Belledonne B650
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Belledonne B650
cubicles

LF1 (SF6)
R400 & R400D (SF6)
Evolis (Vacuum)

DIS

PE90398

Main technical characteristics

PE90396

DIS
Rated Voltage Un (50/60 Hz)
7.2 kV
25 to 31.5 kA* with fuses

400 A to 1250 A
Rated Current (Ir)

R400 / R400D

LF1 / Evolis

Rated Voltage Un (50/60 Hz)

PE90398

* Intensity short circuit (Isc)

7.2 kV
31.5 kA

630 A to 1250 A
400 A to 630 A
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1958

1976

1992

ECOFIT

1988

End
of life

Ongoing

PE90437

PE90393

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-6

LF1 / R400 / R400D /


Evolis

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Belledonne B900
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Belledonne B900
cubicles

DIS

SF1 (SF6)

Main technical characteristics


PE90397

PE90396

DIS
Rated Voltage Un (50/60 Hz)
23 kV
12.5 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90399

SF1
Rated Voltage Un (50/60 Hz)
24 kV
25 kA*

630 A to 1250 A
400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1961

1978

1992

ECOFIT

1988

End
of life

Ongoing

SF1

PE90437

PE90393

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-7

MV CB or Contactor or Disconnector

Medium Voltage Distribution

BVP 17
To give a new life to your installations
Original brand:
AEI, GEC, GEC
ALSTHOM
Version type:
withdrawable
device compatible
with BVP 17
cubicles

BVP 17 (Oil)

VMX (Vacuum)

PE90605

Main technical characteristics

PE90396

BVP 17
Rated Voltage Un (50/60 Hz)
11 kV
1250 A
Up to 25 kA*

800 A
400 A
Rated Current (Ir)

PE90606

* Intensity short circuit (Isc)

VMX
Rated Voltage Un (50/60 Hz)
11 kV
1250 A
Up to 25 kA*

800 A
400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1965

1984

2006

ECOFIT

2001

End
of life

Ongoing

PE90437

PE90604

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-8

VMX

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Cemabloc-C23mc 15 & 27
To give a new life to your installations
Original brand:
CEM
Version type:
withdrawable
device
compatible with
CEMABLOCC23mc 15 et 27
cubicles

CB

FP (SF6)

Main technical characteristics


PE90462

CB
Rated Voltage Un (50/60 Hz)
23 kV
12.5 - 16/25 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90463

PE90419

FP
Rated Voltage Un (50/60 Hz)
23 kV
12.5 - 16/25kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1963

1984

1994
2010 ECOFIT

End
of life

Ongoing

FP

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90461

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-9

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Cemabloc-C23mc 15 & 27
To give a new life to your installations
Original brand:
CEM
Version type:
withdrawable
device
compatible with
CEMABLOCC23mc 15 et 27
cubicles

CB

HVX (Vacuum) 6 poles

6 poles

PE90464

Main technical characteristics


CB
Rated Voltage Un (50/60 Hz)
23 kV
12.5 - 16/25 kA*

2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90465

PE90419

HVX
Rated Voltage Un (50/60 Hz)
23 kV
12.5 - 16/25 kA*

2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1963

1984

1994
2010 ECOFIT

End
of life

Ongoing

PE90437

PE90461

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-10

HVX

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Cemafluor - C26.0
To give a new life to your installations
Original brand:
CEM
Version type:
withdrawable
device
compatible with
CEMAFLUOR
C26.0
cubicles

CS

FPR (SF6)

Main technical characteristics


PE90467

CS
Rated Voltage Un (50/60 Hz)
24 kV
14.5 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90468

PE90466

FPR
Rated Voltage Un (50/60 Hz)
24 kV
14.5 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1976

1982

1991

ECOFIT

1985

End
of life

Ongoing

FPR

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90466

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-11

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Chamrousse
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Chamrousse
cubicles

LF2 (SF6)
R400 (SF6)
R400D (SF6)

DIS

Main technical characteristics


Rated Voltage Un (50/60 Hz)
7.2 kV

12 kV

PE90447

DIS

25 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)


7.2 kV

12 kV

630 A to 1250 A

LF2 (25 kA*)

80 A to 250 A

R400/R400D (10 kA*)

PE90448

PE90446

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1968

1974

1992

ECOFIT

1989

End
of life

Ongoing

PE90437

PE90446

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-12

LF2 / R400 / R400D

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Composit 15-24 kV
To give a new life to your installations
Original brand:
Nuova Magrini
Galileo
Version type:
withdrawable
device
compatible
with Composit
cubicles

MG

SF1 (SF6)

150-500

150-750

350-750

150-750

350-750

PE90576

PE90575

MG
Rated Voltage Un (50/60 Hz)

630 to 1250 A

10 kV

15 kV

17 kV

20 kV

24 kV

8.7 to
28.9 kA*

5 to
29 kA*

12.5 to
29 kA*

3.6 to
24 kA*

6.3 to
21.7 kA*

20 kV

24 kV

PE90576

Main technical characteristics

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90232

SF1**
Rated Voltage Un (50/60 Hz)
10 kV

15 kV

630 to 1250 A

17.5 kV
25 kA*

Rated Current (Ir)


* Intensity short circuit (Isc) ** For Composit panel 860 mm wide

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1966

1993

2015

ECOFIT

2000

End
of life

Ongoing

SF1

PE90437

PE90575

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-13

MV CB or Contactor or Disconnector

Medium Voltage Distribution

CSIM 1-12
To give a new life to your installations
Original
brand: VEB Otto
Buchwitz
Starkstromanlagenbau Dresden
Version type:
withdrawable
device compatible
with CSIM 1-12
cubicles

SCI-4

VEIVACUUM F (Vacuum)

PE90561

Main technical characteristics


SCI-4
Rated Voltage Un (50/60 Hz)

PE90560

12 kV
16 to 31.5 kA*

630 A to 1250 A
Rated Current (Ir)

PE90562

* Intensity short circuit (Isc)

VEIVACUUM F
Rated Voltage Un (50/60 Hz)
12 kV
16 to 31.5 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

1975

1991

End of
spare parts

2009 ECOFIT

End
of life

Ongoing
VEIVACUUM F

PE90437

PE90643

PE90563

Offer extension

PE90488

MiCOM P
series 10 - 20 - 30 - 40

Sepam
series 10 - 20 - 40 - 60 - 80

B-14

MV CB or Contactor or Disconnector

Medium Voltage Distribution

CSIM 3-12
To give a new life to your installations
Original
brand: VEB Otto
Buchwitz
Starkstromanlagenbau Dresden
Version type:
withdrawable
device compatible
with CSIM 3-12
cubicles

VEIVACUUM F (Vacuum)
VA 10031 (Vacuum)

SCI-4

PE90640

Main technical characteristics


SCI-4
Rated Voltage Un (50/60 Hz)

PE90640

12 kV
16 to 31.5 kA*

630 A to 2500 A
Rated Current (Ir)

PE90641

* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)


12 kV

VA (16 to 31.5 kA*)

1600 A to 2500 A

VEIVACUUM F

630 A to 1250 A

(16 to 31.5 kA*)


Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1975

1981

1991
2012 ECOFIT

End
of life

Ongoing
VEIVACUUM F - VA

PE90437

PE90643

PE90563

Offer extension

PE90488

MiCOM P
series 10 - 20 - 30 - 40

Sepam
series 10 - 20 - 40 - 60 - 80

B-15

MV CB or Contactor or Disconnector

Medium Voltage Distribution

D-12
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device compatible
with D-12 cubicles

PE90648

BAL
VAA
VA

VAA (Vacuum)
VA (Vacuum)

PE90648

Main technical characteristics


Rated Voltage Un (50/60 Hz)
12 kV
1600 A

VA (25 to 31.5 kA*)


VAA (20 to 25 kA*) BAL (10 to 20 kA*)

200 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90650

Rated Voltage Un (50/60 Hz)


12 kV
1600 A

VA (25 to 31.5 kA*)

630 A to 1250 A

VAA (20 to 25 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1994

2004

Ongoing

ECOFIT

2004

End
of life

Ongoing

PE90437

PE90649

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-16

VAA, VA

MV CB or Contactor or Disconnector

Medium Voltage Distribution

D-24
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device compatible
with D-24 cubicles
PE90651

BAL
VAA

VAA (Vacuum)

PE90651

Main technical characteristics


Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A

VAA (16 to 25 kA*)


BAL (10 to 16 kA*)

100 A to 630 A
Rated Current (Ir)

PE90650

* Intensity short circuit (Isc)

VAA
Rated Voltage Un (50/60 Hz)
24 kV
10 to 25 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1994

2004

Ongoing

ECOFIT

2004

End
of life

Ongoing

VAA, VA

PE90437

PE90649

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-17

MV CB or Contactor or Disconnector

Medium Voltage Distribution

DNF4-2E
To give a new life to your installations
Original brand:
Alsthom
Version type:
withdrawable
device compatible
with DNF4-2E
cubicles

FP (SF6)
HVX (Vacuum)
CVX (Vacuum)

PE90667

FP (SF6)
GFA (SF6)

PE90668

Main technical characteristics


FP - GFA
Rated Voltage Un (50/60 Hz)
12 kV
40 kA*

400 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90669

FP - HVX - CVX
Rated Voltage Un (50/60 Hz)
12 kV
40 kA*

400 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1983

1997

2007

2009 ECOFIT

End
of life

Ongoing

FP
HVX - CVX

PE90437

PE90670

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-18

PE90671

PE90488

MiCOM P series 10 - 20 - 30 - 40

MV CB or Contactor or Disconnector

Medium Voltage Distribution

DNF4 MI&FI
To give a new life to your installations
Original brand:
Alsthom
Version type:
withdrawable
device compatible
with DNF4 MI&FI
cubicles

FP (SF6)
HVX (Vacuum)

PE90671

FP (SF6)

Main technical characteristics


PE90672

FP
Rated Voltage Un (50/60 Hz)
12 kV
40 kA*

400 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90673

FP - HVX
Rated Voltage Un (50/60 Hz)
12 kV
40 kA*

400 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1983

1997

2007

2010 ECOFIT

End
of life

Ongoing

FP
HVX

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90671

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-19

MV CB or Contactor or Disconnector

Medium Voltage Distribution

DNF5/DNF5-2B
To give a new life to your installations
Original brand:
Alsthom
Version type:
withdrawable
device compatible
with DNF5 /
DNF5-2B cubicles

FP (SF6)
HVX (Vacuum)

PE90678

FP (SF6)

Main technical characteristics


PE90672

FP
Rated Voltage Un (50/60 Hz)
17.5 kV
40 kA*

630 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90673

FP - HVX
Rated Voltage Un (50/60 Hz)
17.5 kV
40 kA*

630 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1983

1997

2007

2011 ECOFIT

End
of life

Ongoing

PE90437

PE90678

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-20

FP
HVX

MV CB or Contactor or Disconnector

Medium Voltage Distribution

DNF6
To give a new life to your installations
Original brand:
Alsthom
Version type:
withdrawable
device compatible
with DNF6 cubicles

FP (SF6)
HVX (Vacuum)

PE90679

FP (SF6)

Main technical characteristics


PE90680

FP
Rated Voltage Un (50/60 Hz)
24 kV
31.5 kA*

400 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90673

FP - HVX
Rated Voltage Un (50/60 Hz)
24 kV
31.5 kA*

400 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1987

1997

2007

2011 ECOFIT

End
of life

Ongoing

FP
HVX

PE90437

PE90679

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-21

MV CB or Contactor or Disconnector

Medium Voltage Distribution

DNF7
To give a new life to your installations
Original brand:
Alsthom
Version type:
withdrawable
device compatible
with DNF7 cubicles

FP (SF6)
HVX-O2 (Vacuum)

PE90674

FP (SF6)

Main technical characteristics


PE90675

FP
Rated Voltage Un (50/60 Hz)
36 kV
31.5 kA*

400 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90676

FP - HVX-O2
Rated Voltage Un (50/60 Hz)
36 kV
31.5 kA*

400 A to 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1987

2010

Ongoing

ECOFIT

06/2013

End
of life

Ongoing

PE90437

PE90674

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-22

FP
HVX-02

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Epoclad
To give a new life to your installations
Original brand:
Nuova Magrini
Galileo
Version type:
withdrawable
device
compatible with
Epoclad cubicles

LF1 (SF6)
LF2 (SF6)
LF3 (SF6)
SF1 (SF6)

DHF
F

Rated Voltage Un (50/60 Hz)


PE90577

6 kV
630 A to
3150 A

7.2 kV

10 kV

12 kV

15 kV

17 kV

20 kV

24 kV

PE90578

Main technical characteristics

20DHF
6DHF
6DHF/N 7F/N
250-500
(20 48 kA*)

350-750
12F
15DHF 12F/N 24DHF (8 -

10DHF 7F

250-350 250-750 350-750 350-850


(29 (12 (18 (13.5 34 kA*) 43 kA*) 48 kA*) 32.5 kA*)

350-500
350-750
(9.2 (12.5 14.5 kA*)
48 kA*)

18 kA*)

24F
500-750
(12.5 18 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

7.2 kV
3150 A
2000 A
630 A to
1250 A

12 kV

17.5 kV

PE90579

Rated Voltage Un (50/60 Hz)


24 kV

LF3 (50 kA*)


LF2 (50 kA*)
LF1 (31.5 kA*)

LF3 (40 kA*)

LF2 (40 kA*)

SF1 (25 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1969

1997

2015

ECOFIT

2005

End
of life

Ongoing

LF1, LF2, LF3, SF1

PE90437

PE90577

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-23

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Fluair F100-F200
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Fluair F100/200
cubicles

FG1
FG2

LF2 (SF6), LF3 (SF6)


Evolis (Vacuum)

PE90409

Main technical characteristics


PE90410

FG1 / FG2
Rated Voltage Un (50/60 Hz)
7.2 kV

12 kV

17.5 kV

25 to 50 kA*

630 A to 3150 A

25 to 31.5 kA*

Rated Current (Ir)

Rated Voltage Un (50/60 Hz)


7.2 kV
630 A to 3150 A

12 kV

LF2/LF3 (25 to 50 kA*)

17.5 kV

PE90411

* Intensity short circuit (Isc)

LF2/LF3
(29 to 31.5 kA*)

Evolis (40 kA* - 2500 A max)


Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1980

1998

2011

ECOFIT

1999

End
of life

Ongoing

PE90437

PE90409

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-24

LF2, LF3
Evolis

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Fluair F100C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Fluair F100C
cubicles

R400
R400D

R400 (SF6)
R400D (SF6)

Main technical characteristics


PE90413

R400 / R400D
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90412

PE90413

R400 / R400D
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

1980

1988
(always available)

End of
spare parts

ECOFIT

End
of life

Ongoing
R400 / R400D

PE90437

PE90409

Offer extension

PE90488

MiCOM P
series 10 - 20 - 30 - 40

Sepam
series 10 - 20 - 40 - 60 - 80
B-25

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Fluair F400C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Fluair F400C
cubicles

FC4

SF2 (SF6)

PE90415

PE90415

Main technical characteristics


FC4
Rated Voltage Un (50/60 Hz)
36 kV
31.5 to 40 kA*

1250 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90416

SF2
Rated Voltage Un (50/60 Hz)
36 kV
31.5 to 40 kA*

1250 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1980

1987

2000

ECOFIT

1991

End
of life

Ongoing

PE90437

PE90415

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-26

SF2

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Fluair F400G
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Fluair F400G
cubicles

SF1 (SF6)
SF2 (SF6)

FG4

PE90406

Main technical characteristics


Rated Voltage Un (50/60 Hz)

1250 A to 2500 A

24 kV

36 kV

40 kA*

25 to 40 kA*

PE90418

FG4

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90450

SF1 / SF2
Rated Voltage Un (50/60 Hz)

1250 A to 2500 A

24 kV

36 kV

40 kA*

25 to 40 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1986

2002

2009

ECOFIT

2004

End
of life

Ongoing

SF1/SF2

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90406

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-27

MV CB or Contactor or Disconnector

Medium Voltage Distribution

FLUOMATIC F540
To give a new life to your installations
Original brand:
Delle Alsthom
Version type:
fixed device
compatible with
FLUOMATIC
F540 cubicles

FR62

FP62 (SF6)

PE90470

Main technical characteristics


FR62
Rated Voltage Un (50/60 Hz)
24 kV
12.5 to 16/25 kA*

400 A to 630 A
Rated Current (Ir)

PE90471

* Intensity short circuit (Isc)

FP62

PE90469

Rated Voltage Un (50/60 Hz)


24 kV
12.5 to 16/25 kA*

400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1976

1984

1994

ECOFIT

1992

End
of life

Ongoing

PE90437

PE90487

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-28

FP62

MV CB or Contactor or Disconnector

Medium Voltage Distribution

FLUOMATIC F943
To give a new life to your installations
Original brand:
Delle Alsthom
Version type:
fixed device
compatible with
FLUOMATIC
F943
cubicles

FR62

BLV (SF6)

Main technical characteristics


PE90470

FR62
Rated Voltage Un (50/60 Hz)
24 kV
16 to 25 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90474

PE90472

BLV
Rated Voltage Un (50/60 Hz)
24 kV
16 to 25 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1976

1984

1994
1997 ECOFIT

End
of life

Ongoing

BLV

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90487

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-29

MV CB or Contactor or Disconnector

Medium Voltage Distribution

GS-10
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device
compatible with
GS-10 cubicles

GE

VA/VAA (Vacuum)

Main technical characteristics


PE90540

PE90550

GE
Rated Voltage Un (50/60 Hz)
up to 12 kV
16 to 40 kA*

630 A to 3000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90541

VA/VAA
Rated Voltage Un (50/60 Hz)
up to 12 kV
16 to 40 kA*

630 A to 3000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1966

1978

2011

ECOFIT

2004

End
of life

Ongoing

PE90437

PE90539

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-30

VA / VAA

MV CB or Contactor or Disconnector

Medium Voltage Distribution

HMC 400 & HMC 410


To give a new life to your installations
Original brand:
GEC Industrial
Controls,
GEC, GEC
Alstom, Alstom
Version type:
withdrawable
vacuum motor
starter

HMC 400 (Vacuum)


HMC 410 (Vacuum)

HMC 400 (Vacuum)


HMC 410 (Vacuum)

Main technical characteristics


PE90594

HMC 400 & HMC 410


Rated Voltage Un (50/60 Hz)
3.3 kV

6.6 kV

43.8 kA*

26.3 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

HMC 400 & HMC 410

Gemstart

PE90595

PE90594

400 A

Rated Voltage Un (50/60 Hz)

400 A

3.3 kV

6.6 kV

Motors up to 13.8 kV / 400 A.

43.8 kA*

26.3 kA*

(self selecting).
Multi-Voltage Inputs from 24 V
to 256 V AC or DC.

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1960

1970

Ongoing

ECOFIT

End
of life

Ongoing
refurbishment,
using Gemstart unit

Refurbishment

In-house refurbishment, including vacuum contactors and


control scheme utlilising Gemstart unit, on site maintenance
B-31

MV CB or Contactor or Disconnector

Medium Voltage Distribution

HMC 1072
To give a new life to your installations
Original brand:
GEC Industrial
Controls, GEC,
GEC Alstom,
Alstom
Version type:
withdrawable
vacuum motor
starter

HMC 1072 (Vacuum)

HMC 1072 (Vacuum)

PE90599

Main technical characteristics

PE90599

HMC 1072
Rated Voltage Un (50/60 Hz)
7.2 kV
63 kA* r.m.s./1s - 50 kA* r.m.s./3s

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

HMC 1072
Rated Voltage Un (50/60 Hz)
7.2 kV
63 kA* r.m.s./1s - 50 kA* r.m.s./3s

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1968

1983

Ongoing

1992

ECOFIT

End
of life

Ongoing

PE90437

PE90599

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-32

using OEM* designed


adapter, in-house
refurbishment,
on-site maintenance

MV CB or Contactor or Disconnector

Medium Voltage Distribution

HMC 1172
To give a new life to your installations
Original brand:
GEC Industrial
Controls, GEC,
GEC Alstom,
Alstom
Version type:
withdrawable
vacuum motor
starter

HMC 1172 (Vacuum)

HMC 1172 (Vacuum)

Main technical characteristics


PE90600

HMC 1172
Rated Voltage Un (50/60 Hz)
7.2 kV
63 kA* r.m.s./1s - 50 kA* r.m.s./3s

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

HMC 1172
Rated Voltage Un (50/60 Hz)

PE90600

7.2 kV
63 kA* r.m.s./1s - 50 kA* r.m.s./3s

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1980

2006

Ongoing

2008

ECOFIT

End
of life

Ongoing

using cubicles and


trucks still under
manufacture,
refurbishment,
on-site maintenance

PE90437

PE90601

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-33

MV CB or Contactor or Disconnector

Medium Voltage Distribution

HMX 36
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom
Version type:
withdrawable
vacuum
switchgear

HMX 36 (Vacuum)

HMX 36 (Vacuum)

Main technical characteristics


PE90602

HMX 36
36 kV
25 kA* r.m.s./1s - 31.5 kA* r.m.s./3s

400 A

PE90602

Rated Voltage Un (50/60 Hz)

Rated Current (Ir)


* Intensity short circuit (Isc)

HMX 36
Rated Voltage Un (50/60 Hz)
36 kV
25 kA* r.m.s./1s - 31.5 kA* r.m.s./3s

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1980

2003

Ongoing

ECOFIT

End
of life

Ongoing

PE90437

PE90602

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-34

using cubicles and


trucks still under
manufacture,
refurbishment,
on-site maintenance

MV CB or Contactor or Disconnector

Medium Voltage Distribution

KIT25-PGDT
To give a new life to your installations
Original brand:
CEM
Version type:
fixed device
compatible
with KIT 25 PGDt cubicles

CC

FP (SF6)

PE90476

Main technical characteristics


CC
Rated Voltage Un (50/60 Hz)
24 kV
12.5 & 14.5 kA*

400 A
Rated Current (Ir)

PE90477

* Intensity short circuit (Isc)

FP

PE90475

Rated Voltage Un (50/60 Hz)


24 kV
12.5 & 14.5 kA*

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1969

1978

1988
1993 ECOFIT

End
of life

Ongoing

FP

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90487

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-35

MV CB or Contactor or Disconnector

Medium Voltage Distribution

KIT 27.2-PGHT
To give a new life to your installations
Original brand:
CEM
Version type:
fixed device
compatible
with KIT 27.2 PGHt cubicles

HF4K

FP (SF6)

Main technical characteristics


PE90479

HF4K
Rated Voltage Un (50/60 Hz)
24 kV
14.5 & 25 kA*

400 A
Rated Current (Ir)

PE90480

* Intensity short circuit (Isc)

FP

PE90478

Rated Voltage Un (50/60 Hz)


24 kV
14.5 & 25 kA*

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1985

1987

1997

1993

ECOFIT

End
of life

Ongoing

PE90437

PE90478

Offer extension

PE90488

MiCOM P
series 10 - 20 - 30 - 40

Sepam
series 10 - 20 - 40 - 60 - 80

B-36

FP

MV CB or Contactor or Disconnector

Medium Voltage Distribution

L
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device
compatible with
L cubicles

Type D
and E

HVX (Vacuum)

PE90557

Main technical characteristics


PE90558

D, E
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV
20 to 50 kA*

400 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90559

HVX
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV
20 to 50 kA*

400 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1965

1972

2003
2004 ECOFIT

End
of life

Ongoing

HVX

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90549

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-37

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Metalclad switchgear
To give a new life to your installations
Original brand:
Federal Pioneer
Version type:
withdrawable
device compatible
with metalclad
switchgear

DST 2V (Vacuum)
DST 5V (Vacuum)

DST 2 & 5
(Air Magnetic Breakers))

Rated Voltage Un (50/60 Hz)


5 kV

15 kV

PE90618

Main technical characteristics

3000 A
2000 A
PE90618-2

DST 2 & 5 (250 - 350 MVA)

DST 2 (500 - 750 MVA)

1200 A
Rated Current (Ir)

Rated Voltage Un (50/60 Hz)


5 kV

15 kV

PE90619

* Intensity short circuit (Isc)

3000 A
2000 A

DST 2V (350 MVA)

DST 5V (500 - 750 MVA)

1200 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

End
of life

1970

1985

2000

2011

1999

ECOFIT

Rack mechanism
added

DST 2V & 5V (Vacuum)

Main characteristics
Magnum circuit breakers correctly interface with
the existing breaker compartment components
and maintain safety interlocks inherent in the
original equipment design.

PE90619

PE90619

1HZFLUFXLWEUHDNHUVDUHLQVWDOOHGLQH[LVWLQJ
switchgear.
2ULJLQDOIRRWSULQWLVOHIWLQWDFWVDYLQJWLPHDQG
money.
,QVWDOODWLRQH[SHQVHLVDIUDFWLRQRIQHZ
equipment costs.
Less down time for installation.
Enhanced equipment reliability.
0DQXIDFWXUHGZLWKQHZFRPSRQHQWV
8QGHUJRHVFRPSOHWHIDFWRU\WHVWLQJ
%DFNHGE\RXUVWDQGDUGHTXLSPHQWZDUUDQWy.
1HwHDV\WRPDLQWDLQRSHUDWLQJPHFKDQLVP
1REXON\DUFFKXWHVWRKDQGOHDQGPDLQWDLQ
B-38

Optional capabilities
,QFUHDVHGIDXOWFXUUHQWLQWHUUXSWLRQUDWLQJ
5HOD\XSJUDGHLPSURYHGDFFXUDF\DQG
repeatabilityDQGSHUIRUPDQFH
Power meteringmonitoring and
communication.
*URXQGDQGWHVWGHYLFHVDYDLODEOHIRUYDULRXV
types of switchgear.

Closed Door Electric Racking Mechanism:


1RVWRUDJHVSDFHLVUHTXLUHGIRUWKHHOHFWULFDO
racking system
5HTXLUHMXVWDFRPPRQV$&A outlet for
power up.

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Motorstart P12D/P30D
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Motorstart P12D/
P30D cubicles

R400 (SF6)
R400D (SF6)

KA, KDA

PE90387

Main technical characteristics


PE90388

KA / KDA
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

90 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90389

R400 / R400D
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1960

1980

1992

ECOFIT

1988

End
of life

Ongoing

R400 / R400D

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90387

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-39

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Motorstart P50D
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Motorstart P50D
cubicles

R400 (SF6)
R400D (SF6)
CTV1 (Vacuum)

C, CD

PE90390

Main technical characteristics


PE90391

C / CD
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 200 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90392

R400 / R400D
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1960

1980

1992

ECOFIT

1988

End
of life

Ongoing

PE90437

PE90387

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-40

R400 / R400D / CTV1

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Motorstart P500D
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Motorstart P500D
cubicles

R400 (SF6)
R400D (SF6)
CTV1 (Vacuum)

PE90393

C1, CD1

Main technical characteristics


PE90394

C1 / CD1
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90395

R400 / R400D
Rated Voltage Un (50/60 Hz)
7.2 kV
50 kA* with fuses

80 A to 250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1971

1988

1998

ECOFIT

1988

End
of life

Ongoing

R400 / R400D / CTV1

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90393

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-41

MV CB or Contactor or Disconnector

Medium Voltage Distribution

MX51 & MX81


To give a new life to your installations
Original brand:
GEC, GEC Alstom
Version type:
fixed pattern
vacuum
switchgear

MX 51 (Vacuum)
MX 81 (Vacuum)

MX 51 (Vacuum)
MX 81 (Vacuum)

Main technical characteristics


Rated Voltage Un (50/60 Hz)
3.6 kV
2000 A
1250 A
630 A

PE90603

17.5 kV

MX51 (31.5 kA*)


MX51 (25 kA*)

MX51 (31.5 kA*)


MX81 (12.5 kA*)
MX81 (20 kA*)

MX51 (25 kA*)

MX81 (12.5 kA*)


MX81 (20 kA*)

Rated Current (Ir)


PE90603

* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)


3.6 kV
2000 A

MX51 (31.5 kA*)

1250 A
630 A

17.5 kV

MX51 (25 kA*)

MX51 (31.5 kA*)


MX81 (12.5 kA*)
MX81 (20 kA*)

MX51 (25 kA*)

MX81 (12.5 kA*)


MX81 (20 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1974

1981

Ongoing

ECOFIT

End
of life

Ongoing

PE90603

PE90437

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-42

refurbishment,
on-site maintenance,
replacement of
vacuum
circuit breakers

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Normabloc N1347
To give a new life to your installations
Original brand:
Delle Alsthom
Version type:
withdrawable
device
compatible with
NORMABLOC
N1347 cubicles

HVX (Vacuum)
FPX (Vacuum)

HL

PE90482

Main technical characteristics


HL
Rated Voltage Un (50/60 Hz)
17.5 kV
25 & 40 kA*

630 A to 1250 A
Rated Current (Ir)

PE90475

PE90483

* Intensity short circuit (Isc)

HVX / FPX
Rated Voltage Un (50/60 Hz)
17.5 kV
25 & 40 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1975

1981

1991
2009 ECOFIT

End
of life

Ongoing

HVX/FPX

PE90437

PE90481

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-43

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Normasept N743
To give a new life to your installations
Original brand:
Delle Alsthom
Version type:
fixed device
compatible with
NORMASEPT
N743 cubicles

HL

FP (SF6)

Main technical characteristics


PE90485

HL
Rated Voltage Un (50/60 Hz)
24 kV
12.5 to 14.5 kA*

400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90486

PE90484

FP
Rated Voltage Un (50/60 Hz)
24 kV
12.5 to 14.5 kA*

400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1971

1981

1991

ECOFIT

1990

End
of life

Ongoing

PE90437

PE90487

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-44

FP

MV CB or Contactor or Disconnector

Medium Voltage Distribution

PA, SC, SD
To give a new life to your installations
Original brand:
Concordia
Sprecher
Version type:
withdrawable
device compatible
with PA, SC and
SD panels

HP T/W/Z

HVX (Vacuum)

Main technical characteristics


PE90653

HP 300 - 500
Rated Voltage Un (50/60 Hz)
7.2 kV to 12 kV

24 kV

12.5 to 40 kA*

1250 A to 3150 A

8.4 to 21.7 kA*

800 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90652

HVX

PE90653

Rated Voltage Un (50/60 Hz)


7.2 kV to 12 kV

20/24 kV

2500 A to 3150 A
16 to 50 kA*

630 A to 2500 A

16 to 31.5 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1976

2002

Ongoing

2007

ECOFIT

End
of life

Ongoing

HVX

PE90437

PE90654

Offer extension

PE90488

MiCOM P
series 10 - 20 - 30 - 40

Sepam
series 10 - 20 - 40 - 60 - 80
B-45

MV CB or Contactor or Disconnector

Medium Voltage Distribution

R
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device
compatible with
R cubicles

E-Breaker
M-Breaker

VA/VAA (Vacuum)

Main technical characteristics


PE9055

E/M
Rated Voltage Un (50/60 Hz)
12 kV

17 - 24 kV

36 kV

4000 A
2500 A

25 to 50 kA*
16 to 31.5 kA*

1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90554

12 kV

17 kV

36 kV

VA

4000 A

(up to 31.5 kA*)

VA
2500 A

24 kV

PE90556

Rated Voltage Un (50/60 Hz)

(up to 50 kA*)

VA

VA

VA

(up to 40 kA*) (up to 31.5 kA*) (up to 40 kA*)


1250 A

VAA

VAA

(up to 25 kA*)

(up to 25 kA*)

VA

VA

VA

(up to 31.5 kA*)

(up to 50 kA*)

(up to 31.5 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1973

1990

2003

ECOFIT

1999

End
of life

Ongoing

PE90437

PE90554

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-46

VA / VAA

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Siclad
To give a new life to your installations
Original brand:
Ansaldo
Version type:
withdrawable
device
compatible with
Siclad cubicles

MAG II

LF2 (SF6)

PE90580

Main technical characteristics


6 kV
630 A to 2000 A

10 kV

PE90581

Rated Voltage Un (50/60 Hz)


15 kV

MAG II - 6 - 250 MAG II - 10 - 500 MAG II - 15 - 350


MAG II - 6 - 400
MAG II - 15 - 300
(20 to 28 kA*)

(20 to 48 kA*)

(12 to 30 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90582

LF2**
Rated Voltage Un (50/60 Hz)
6 kV

10 kV

15 kV

LF2 (40 kA*)

2000 A
630 A to 1250 A

LF1 (31.5 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc) ** For Siclad panel 730 mm & 850 mm wide

A true extended life time


Commercialisation

End of
commercialisation

1969

1997

End of
spare parts

ECOFIT

2009

End
of life

Ongoing

LF2

PE90437

PE90580

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-47

Medium Voltage Distribution

MV CB or Contactor or Disconnector
Solenarc DSE Metal-Clad Switchgear

To give a new life to your installations


Original brand:
Square D
Version type:
Draw-out

Type DSE

Magnum CB (Vacuum)

Rated Voltage Un (50/60 Hz)


5 kV

15 kV

PE90540

Main technical characteristics

3000 A
2000 A

DSE-23B (250 MVA)

DSE (250 - 1000 MVA)

1200 A

Rated Voltage Un (50/60 Hz)


5 kV

15 kV

PE90541

Rated Current (Ir)

PE90461

3000 A
2000 A

5MGSB (250 MVA)

15MGSB (250 - 1000 MVA)

1200 A
Rated Current (Ir)

Magnum CB main
characteristics

B-48

Commercialisation

End of
commercialisation

End of
spare parts

< 1975

1988

2005

ECOFIT

1999

End
of life

Ongoing

PE90437

Offer extension

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90539

Built with totally new


components and tested to
ANSI standards,
Magnum circuit breakers
correctly interface with
the existing breaker
compartment components
and maintain safety
interlocks inherent
in the original equipment
design.
s New circuit breakers
are installed in existing
switchgear.
s Original footprint is left
intact, saving time and
money.
s Installation expense is
a fraction of new
equipment costs.
- Less down time for
installation.
- Enhanced equipment
reliability.
s Manufactured with new
components.
s Undergoes complete
factory testing.
s Backed by our standard
equipment warranty.
s New, easy-to-maintain
operating mechanism.
s No bulky arc chutes
to handle and maintain.
s Reduced need for difficult
to obtain spare parts.

A true extended life time

Sepam series 10 - 20 - 40 - 60 - 80

Magnum CB

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Taillefer T900-T1080
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
Taillefer
T900 / T1080
cubicles

DST

LF3 (SF6)

Main technical characteristics


DST

1250 A to 2500 A

7.2 kV

17.5 kV

50 kA*

31.5 kA*

PE90408

Rated Voltage Un (50/60 Hz)

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90406
PE90407

LF3
Rated Voltage Un (50/60 Hz)

1250 A to 2500 A

7.2 kV

17.5 kV

50 kA*

31.5 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1965

1974

1986
1989 ECOFIT

End
of life

Ongoing

LF3

PE90437

PE90406

Offer extension

PE90488

MiCOM P
series 10 - 20 - 30 - 40

Sepam
series 10 - 20 - 40 - 60 - 80
B-49

MV CB or Contactor or Disconnector

Medium Voltage Distribution

Venus
To give a new life to your installations
Original brand:
Nuova Magrini
Galileo
Version type:
withdrawable
device
compatible with
Venus cubicles

GI
GL

LF1 (SF6)
LF3 (SF6)

Main technical characteristics

PE90583

1600 A
to
3150 A
630 A to
1250 A

7 kV

12 kV

GL
(50 kA*)

17 kV

PE90584

Rated Voltage Un (50/60 Hz)


24 kV

36 kV

GL

GL

GL

(20 to 40 kA*)

(25 to 40 kA*)

(20 to 31.5 kA*)

GI

GI

(12.5 to 31.5 kA*)

(12 to 25 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

7 kV
3150 A

LF3**

1600 A

(50 kA*)

630 A to
1250 A

LF1***

12 kV

17 kV

24 kV

36 kV

PE90585

Rated Voltage Un (50/60 Hz)

(31.5 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc) ** For Venus panel 900 mm wide *** For Venus panel 600 mm wide

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1989

2000

2015

ECOFIT

2008

End
of life

Ongoing

PE90437

PE90583

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-50

LF1, LF3

MV CB or Contactor or Disconnector

Medium Voltage Distribution

VM6 DM12
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
withdrawable
device
compatible with
VM6-DM12
cubicles

FB4

SF1 (SF6)

Main technical characteristics


PE90422

PE90415

FB4
Rated Voltage Un (50/60 Hz)

400 A to 1250 A

7.2 kV

12 kV

17.5 kV

12.5 to 31.5 kA*

12.5 to 25 kA*

12.5 to 20 kA*

24 kV

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90423

SF1
Rated Voltage Un (50/60 Hz)
7.2 kV

12 kV

17.5 kV

24 kV

12.5 to 25 kA*

400 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1975

1993

2009
2010 ECOFIT

End
of life

Ongoing

SF1

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90400

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-51

MV CB or Contactor or Disconnector

Medium Voltage Distribution

VM6 DM22-DM23
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
fixed device
compatible with
VM6 DM22/DM23
cubicles

FB4

SF1 (SF6)

Main technical characteristics


PE90565

FB4
Rated Voltage Un (50/60 Hz)
24 kV
12.5 to 20 kA*

400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90566

PE90419

SF1
Rated Voltage Un (50/60 Hz)
24 kV
12.5 to 20 kA*

400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1975

1993

2009
2009 ECOFIT

End
of life

Ongoing

PE90437

PE90419

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-52

SF1

MV CB or Contactor or Disconnector

Medium Voltage Distribution

VMX
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom
Version type:
withdrawable
vacuum
switchgear

VMX (Vacuum)

VMX (Vacuum)

Main technical characteristics


PE90692

VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A 1250 A - 2000 A

Up to 25 kA* for 3s

Rated Current (Ir)


* Intensity short circuit (Isc)

VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A 1250 A - 2000 A

PE90692

Up to 25 kA* for 3s

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1987

2004

Ongoing

2004

ECOFIT

End
of life

Ongoing

VMX circuit breaker


ongoing by Services
can also replace
BV17.
A variant can be
replaced by C variant

PE90437

PE90692

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-53

MV CB or Contactor or Disconnector

Medium Voltage Distribution

WAK
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device
compatible with
WAK cubicles

Type D
and E

HVX (Vacuum)

PE90546

Main technical characteristics


PE90547

D&E
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV

20 kV

24 kV

2500 A
1600 A

20 to 34 kA*
15 to 30 kA*

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90548

HVX
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV

20 kV

24 kV

2500 A
1600 A

20 to 34 kA*
15 to 30 kA*

400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1965

1972

2003
2004 ECOFIT

End
of life

Ongoing

PE90437

PE90549

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-54

HVX

MV CB or Contactor or Disconnector

Medium Voltage Distribution

WBA
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device compatible
with WBA cubicles

PE90665

VA (Vacuum)
VAA (Vacuum)
ECA (Vacuum)
BAL (Vacuum)

VA (Vacuum)
VAA (Vacuum)

PE90657

Main technical characteristics


Rated Voltage Un (50/60 Hz)
12 to 24 kV

12 to 24 kV

12 to 38 kV

1250 A to 2500 A
630 A to 1250 A

VAA (16 to 25 kA*)

ECA (20 to 50 kA*) VA (20 to 50 kA*)

Rated Current (Ir)

Rated Voltage Un (50/60 Hz)


12 to 24 kV

12 to 38 kV

PE90664

* Intensity short circuit (Isc)

1600 A to 2500 A
630 A to 1600 A

VAA (16 to 25 kA*)

VA (20 to 50 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1989

2006

Ongoing

2006 ECOFIT

End
of life

Ongoing

VA/VAA

PE90437

PE90657

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-55

MV CB or Contactor or Disconnector

Medium Voltage Distribution

WBB
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device compatible
with WBB cubicles

VA (Vacuum)
VAA (Vacuum)
ECA (Vacuum)

VA (Vacuum)
VAA (Vacuum)

Main technical characteristics


12 to 24 kV

12 to 24 kV

PE90663

Rated Voltage Un (50/60 Hz)


12 to 38 kV

1250 A to 2500 A
630 A to 1250 A

VAA (16 to 25 kA*)

ECA (20 to 50 kA*) VA (20 to 50 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)


12 to 24 kV

12 to 38 kV

PE90664

PE90663

1200 A to 2500 A
630 A to 1200 A

VAA (16 to 30 kA*)

VA (20 to 50 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1989

2006

Ongoing

ECOFIT

2006

End
of life

Ongoing

PE90437

PE90660

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-56

VA/VAA

MV CB or Contactor or Disconnector

Medium Voltage Distribution

WKC
To give a new life to your installations
Original brand:
AEG
Version type:
withdrawable
device compatible
with WKC cubicles

VA (Vacuum)
VAA (Vacuum)
MC (Vacuum)
BAL (Vacuum)

FPX (SF6)
VA (Vacuum)
VAA (Vacuum)

Main technical characteristics


12 to 24 kV

PE90661

Rated Voltage Un (50/60 Hz)


12 to 38 kV

1250 A to 2500 A
630 A to 1250 A

VA (20 to 50 kA*)

VAA (16 to 25 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)
PE90661

3.6 to 7.2 kV

7.2 to 24 kV

2500 A to 4000 A

FPX (31.5

1600 A to 2500 A

to 40 kA*)

PE90650

Rated Voltage Un (50/60 Hz)


12 to 24 kV

12 to 38 kV

VAA

(20 to 50 kA*)

VA

1250 A to 1600 A
630 A to 1250 A

(16 to 25 kA*)
400 A

Contactor
Vacuum
(16 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1987

2003

Ongoing
2004

ECOFIT

End
of life

Ongoing

FPX
VA/VAA

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90662

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-57

MV CB or Contactor or Disconnector

Medium Voltage Distribution

YSF6
To give a new life to your installations
Original
brand: Yorkshire
Switchgear /
Merlin Gerin
Version type:
withdrawable
device compatible
with YSF6 cubicle

YSF6 Evolis (Vacuum)

YSF6 (SF6)

PE90608

PE90607

Main technical characteristics


YSF6
Rated Voltage Un (50/60 Hz)
12 kV
Up to 25 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90609

YSF6 Evolis
Rated Voltage Un (50/60 Hz)
12 kV
Up to 25 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

1981

2001

End of
spare parts

ECOFIT

2004

End
of life

Ongoing

PE90437

PE90419

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-58

YSF6
YSF6 Evolis

B-59

MV Panel

Medium Voltage Distribution

D-12
To give a new life to your installations
Original brand:
AEG
Version type:
Air Insulated
Switchgear
PE90648

D-12

D-12

Main technical characteristics


D-12
Rated Voltage Un (50/60 Hz)
12 kV
25 to 31.5 kA*

1600 A

10 to 20 kA* - 20 to 25 kA*

200 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

D-12
Rated Voltage Un (50/60 Hz)
12 kV
25 to 31.5 kA*

1600 A

20 to 25 kA*

630 A to 1250 A
Rated Current (Ir)

PE90648

* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

1994

2004

2004

ECOFIT

End of
spare parts

End
of life

Ongoing

PE90437

PE90648

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-60

Complete D-12
panels by Services

MV Panel

Medium Voltage Distribution

D-24
To give a new life to your installations
Original brand:
AEG
Version type:
Air Insulated
Switchgear

D-24

D-24

Main technical characteristics


D-24
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 2150 A

16 to 25 kA*

100 A to 630 A

10 to 16 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

D-24

PE90649

Rated Voltage Un (50/60 Hz)


24 kV
10 to 25 kA*

630 A to 1250 A
Rated Current (Ir)

PE90651

* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

1994

2004

2004

ECOFIT

End of
spare parts

End
of life

Ongoing

Complete D-24
panels by Services

PE90437

PE90649

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-61

MV Panel

Medium Voltage Distribution

F100/200
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
Air Insulated
Switchgear

F100/200

F100/200

Main technical characteristics


Rated Voltage Un (50/60 Hz)
7.2 kV

12 kV

17.5 kV

F100

F200

(25 to 50 kA*)

(25 to 50 kA*)

630 A to 3150 A
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90645

F100/200
Incomer / Feeder / Coupling (arc proof in option)
Rated Voltage Un (50/60 Hz)
7.2 kV

12 kV

17.5 kV

25 to 50 kA*

630 A to 3150 A

PE90644

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1980

1998

Ongoing

1998

ECOFIT

End
of life

Ongoing

PE90437

PE90645

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-62

Complete F100/200
panels by Services

MV Panel

Medium Voltage Distribution

F100C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
Air Insulated
Switchgear

F100C

PE90645

F100C

Main technical characteristics


F100C
Rated Voltage Un (50/60 Hz)
7.2 kV
8 to 50 kA* (with fuses)

630 A to 2500 A
Rated Current (Ir)
* Intensity short circuit (Isc)

F100C
Rated Voltage Un (50/60 Hz)
7.2 kV
8 to 50 kA* (with fuses)

630 A to 2500 A

PE90644

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1980

1998

Ongoing

1998

ECOFIT

End
of life

Ongoing

Complete F100C
panels by Services

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90645

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-63

MV Panel

Medium Voltage Distribution

PX12-24
To give a new life to your installations
Original brand:
Alstom
Version type:
Air Insulated
Switchgear

PX 12-24

PX 12-24

PE90677

Main technical characteristics


Rated Voltage Un (50/60 Hz)
12 kV

24 kV

2500 A to 3150 A

PX 12 (25 to 40 kA*)

400 A to 2500 A

PX 24 (16 - 25 - 31.5 kA*)

Rated Current (Ir)


* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)


12 kV

24 kV

2500 A to 3150 A

PX 12 (25 to 40 kA*)

400 A to 2500 A

PX 24 (16 - 25 - 31.5 kA*)


PE90677

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1993

1997

Ongoing

1997

ECOFIT

End
of life

Ongoing

PE90437

PE90677

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-64

Complete PX panels
by Services

MV Panel

Medium Voltage Distribution

R
To give a new life to your installations
Original brand:
AEG
Version type:
Air Insulated
Switchgear

PE90655

Main technical characteristics


R
Rated Voltage Un (50/60 Hz)

400 A to 2500 A

12 kV

24 kV

31.5 to 40 kA*

16 to 25 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

R
Rated Voltage Un (50/60 Hz)

400 A to 2500 A

12 kV

24 kV

20 to 40 kA*

16 to 25 kA*
PE90655

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1973

1990

Ongoing

1990

ECOFIT

End
of life

Ongoing

Complete R panels
by Services

PE90437

PE90655

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-65

MV Panel

Medium Voltage Distribution

VMX
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom
Version type:
Air Insulated
Switchgear.
Withdrawable
vacuum
switchgear

VMX (Vacuum)

VMX (Vacuum)

Main technical characteristics

PE90692

VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A 1250 A - 2000 A

Up to 25 kA* for 3s

Rated Current (Ir)


* Intensity short circuit (Isc)

VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A 1250 A - 2000 A

Up to 25 kA* for 3s
PE90692

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1987

2004

Ongoing

2004

ECOFIT

End
of life

Ongoing

PE90437

PE90692

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-66

Complete VMX panels


ongoing by Services
or BV17 extension

MV Panel

Medium Voltage Distribution

WBA
To give a new life to your installations
Original brand:
AEG
Version type:
Air Insulated
Switchgear

WBA

WBA

Main technical characteristics


WBA
Rated Voltage Un (50/60 Hz)
12 to 24 kV
1250 A to 2500 A

20 to 50 kA*

630 A to 1250 A

16 to 25 kA* & 20 to 50 kA*

12 to 38 kV
20 to 50 kA*

PE90657

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90657

WBA
Rated Voltage Un (50/60 Hz)
12 to 24 kV

12 to 38 kV

1600 A to 2500 A
16 to 25 kA*

630 A to 1600 A

20 to 50 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1989

2006

Ongoing

2006

ECOFIT

End
of life

Ongoing

Complete WBA panels


by Services

PE90437

PE90657

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-67

MV Panel

Medium Voltage Distribution

WBB
To give a new life to your installations
Original brand:
AEG
Version type:
Air Insulated
Switchgear

WBB

PE90660

WBB

Main technical characteristics


WBB
12 to 24 kV
1250 A to 2500 A

20 to 50 kA*

630 A to 1250 A

16 to 25 kA* & 20 to 50 kA*

12 to 38 kV

PE90659

Rated Voltage Un (50/60 Hz)

20 to 50 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

WBB
Rated Voltage Un (50/60 Hz)
12 to 24 kV

12 to 38 kV

1200 A to 2500 A
16 to 25 kA*

630 A to 1200 A

20 to 50 kA*

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1989

2006

Ongoing

2006

ECOFIT

End
of life

Ongoing

PE90437

PE90660

Offer extension

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

B-68

Complete WBB panels


by Services

MV Panel

Medium Voltage Distribution

WKC
To give a new life to your installations
Original brand:
AEG
Version type:
Air Insulated
Switchgear

WKC

WKC

Main technical characteristics


WKC
Rated Voltage Un (50/60 Hz)
12 to 24 kV

12 to 38 kV

1250 A to 2500 A
20 to 50 kA*

16 to 25 kA*

630 A to 1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

WKC

PE90661

Rated Voltage Un (50/60 Hz)


3.6 to 7.2 kV

7.2 to 24 kV

12 to 24 kV

12 to 38 kV

2500 A to 4000 A
31.5 to 40 kA*

1600 A to 2500 A

20 to 50 kA*

1250 A to 1600 A
16 to 25 kA*

630 A to 1250 A
16 kA*

400 A

PE90661

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1987

2003

Ongoing

2003

ECOFIT

End
of life

Ongoing

Complete WKC panels


by Services

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90662

Offer extension

Sepam series 10 - 20 - 40 - 60 - 80

B-69

ECOFIT

PE90457

TM

Protection
relays

ECOFITTM

Protection relays

Generic offer
All

C-2

KCGG 122&142

C-3

SEPAM 2000

C-4

VIP11R & VIP12R

C-5

Specific offer

Protection upgrade benefits

C-6

C-1

Generic offer

Protection relays

All
To give a new life to your installations
Original brand:
all brands
Version type:
protection relays
compatible
with all MV
switchboard

MiCOM
Sepam

PE90487

PE90437

Old types

PE90488

MiCOM P series 10 - 20 - 30 - 40

Sepam series 10 - 20 - 40 - 60 - 80

Intelligent Electronic Device (IED) by Schneider Electric


MiCOM

Sepam

Transport

Series 40

C-2

PE90436

8VXDODSSOLFDWLRQV
'LUHFWLRQDOSURWHFWLRQ

Series 40

'HPDQGLQJDSSOLFDWLRQV
&ODVVLFDXWRPDWLRQ*RRVH0HVVDJHV

Series 60

&XVWRPDSSOLFDWLRQV
'LfIHUHQWLDOGLVWDQFHFRPSOH[DXWRPDWLRQ

Series 80

PE90449

Series 20

PE90488

Series 30

PE90437

PE90366

Series 20

6LPSOHDSSOLFDWLRQV8RU,

PE90449

PE90438

Series 10

PE90449

Mining, Minerals & Metal


Specific offer

Protection relays

KCGG122 & 142


To give a new life to your installations
KCGG 122 & 142

MiCOM P123R

PE90634

Original brand:
Alstom
Version type:
draw-out

K range relay - KCGG 122 & 142


Case
Withdrawable case

Language

English

Communication

KBus / Courier

Power supply

24 V / 125 VDC - 48 V / 250 VDC

Digital input supply

48 VDC only

PE90635

Installation

PE90634

Main technical characteristics

MiCOM P123R
Case
Installation

Withdrawable case

Language

Multilanguage

Communication

KBus / Courier, DNP3, IEC60870-5-103

Power supply

24 V / 250 VDC - 48 V / 240 VDC

Digital input supply

According to Power Supply (above)

A true extended life time


Commercialisation

End of commercialisation
by Schneider Electric,
under AREVA brand *

End of support by Schneider Electric

1997

2010

2012

2011

ECOFIT

Ongoing

* Since 2010 commercialisation under Alstom Grid brand

C-3

Specific offer

Protection relays

Sepam 2000
To give a new life to your installations
Sepam 2000

Sepam serie 60/80

Motor application

PE90639

Main technical characteristics


PE90638

PE90638

Original brand:
Merlin Gerin
Version type:
Sepam 2000
series

Sepam 2000

Sepam
serie 80


M06, M07, M08, M14


M02 to M05, M09, M11, M15, M16,
M20 to M23

Substation
application

S02, S03, S06 to S09

Busbar application

B02, B04, B07, B12





S01, S04, S05




B01, B03
Transformer
application
without temp.
measurement

T01 to T03, T06, T07, T09, T10, T12 to T15,


T17 to T19

Transformer
application
with temp.
measurement

T21, T22, T23, T26, T27, T29, T30,


T32 to T35, T37 to T39

Generator
application
Capacitor bank
application
Transformer
diff. application

Sepam
serie 60




T04, T05, T11, T16




T24, T25, T31, T36


G01 to G08, G12, G13, G15 to G18

C02, C04, C06, C08




C01, C03


D02, D22

A true extended life time


Commercialisation

End of
commercialisation

End of
spare parts

1993

2006

2015

2012

ECOFIT

End
of life

Ongoing
Sepam serie 60, 80

C-4

Specific offer

Protection relays

VIP11R-12R for RM6+


To give a new life to your installations
VIP11R
VIP12R

ECOFITTM VIP11-12R

PE90567

RM6 + commercialized between 1987 and 1998

PE90568

VIP11R

or VIP12R

PE90569

PE90569

PE90570

Original brand:
Merlin Gerin
Version type:
VIP11R or
VIP12R
protection relays
compatible for
RM6 +

ECOFIT
VIP11-12R

C-5

Protection upgrade benefits

Protection relays

Improve the performance of your system


with the latest technology in micro-processor
based integrated relays.

Why protection upgrade?


By replacing solid state and older type electromechanical protection relays
with technologically advanced multi-function microprocessor-based digital relays,
the performance accuracy and longevity of your system can be si
With a number of different protection functions Schneider Electric's range of relays
can provide a range of options to include metering; communication; event capture;
monitoring and control. Units are self-diagnostic to provide enhanced reliability.
It is normally possible to use the existing current and potential transformers
and auxiliary digital relay inputs.
Schneider Electric's application based approach makes it easy to select
the appropriate relay for your needs.

What are the benefits?


Accuracy

System protection at the current level reduces unnecessary outages


and minimise stresses to equipment.
Increased accuracy of measurement assists in cost allocation
and understanding power demand requirements.

High reliability from advanced self supervision systems.

Flexibility

The integrated functions of the relay allow for communications and control
of the equipment either as a stand-alone unit or as part of networked systems.

All components in the protection chain are referenced and interface rapidly.

No constraints for integration in cubicles due to the compact size of the base unit.

C-6

Ease of use

Settings and adjustments are entered via the device's keypad


and visually displayed.

Reduced costs

The amalgamation of functions into one self-diagnosing meter


reduces expenditure and saves on space.

Medium & Low Voltage Distribution


Modernisation of switchboards
TM

ECOFIT
Green is our colour
Catalogue 2013

Schneider Electric nv/sa

32VP297EN

Dieweg 3
B-1180 Bruxelles/Brussel
Tel.: (02) 373 75 01
be-aftersales.be@schneider-electric.com
www.schneider-electric.be

TVA/BTW: BE 0451.362.180
RPM Bruxelles/RPR Brussel
ING: 310-1110264-88
IBAN: BE 56 3101 1102 6488
SWIFT BIC: BBRU BE BB

Due to evolution of standards and equipment, the characteristics indicated in


text and images of this document do not constitute a commitment on our part
without conformation.

Printed on recycled paper

Realisation & printing: DeckersSnoeck

03/13

Potrebbero piacerti anche