Sei sulla pagina 1di 4

HST | Stud anchor

HST Stud anchor


Anchor version

Benefits

HST
Carbon steel

- suitable for non-cracked and


cracked concrete C 20/25 to
C 50/60
- quick and simple setting
operation
- safety wedge for certain follow up
expansion

HST-R
Stainless steel
HST-HCR
High corrosion
resistance steel

Concrete

Tensile
zone

Fire
resistance

Shock

Corrosion
resistance

High
corrosion
resistance

European
Technical
Approval

CE
conformity

Hilti anchor
design
software

Approvals / certificates
Description
Authority / Laboratory
European technical approval a)
DIBt, Berlin
Shockproof fastenings in civil
Bundesamt fr Zivilschutz, Bern
defence installations
Fire test report
DIBt, Berlin
Fire test report ZTV-Tunnel
IBMB, Braunschweig
Assessment report (fire)
warringtonfire
a) All data given in this section according ETA-98/0001, issue 2009-07-07.

No. / date of issue


ETA-98/0001 / 2009-07-07
BZS D 08-602 / 2008-12-15
ETA-98/0001 / 2009-07-07
UB 3332/0881-2 / 2003-07-02
WF 166402 / 2007-10-26

Basic loading data (for a single anchor)


All data in this section applies to
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Concrete as specified in the table
- Steel failure
- Minimum base material thickness
- Concrete C 20/25, fck,cube = 25 N/mm

132

For details see Simplified design method

6 / 2010

HST | Stud anchor

Mean ultimate resistance


Cracked concrete

Non-cracked concrete
Anchor size
Tensile NRu,m
HST
HST-R
HST-HCR
Shear VRu,m
HST
HST-R
HST-HCR

M8

M10 M12 M16 M20 M24

M8

M10 M12 M16 M20 M24

[kN]
[kN]
[kN]

16,6
18,1
15,2

22,3
26,7
22,7

35,2
35,1
32,4

48,7
49,8
45,5

76,0
77,4
-

86,1
79,1
-

10,3
12,7
13,8

11,6
18,4
16,2

21,9
20,1
21,5

31,1
36,0
32,4

44,9
55,1
-

[kN]
[kN]
[kN]

17,6
15,8
17,6

27,8
24,4
27,8

40,5
35,4
40,5

67,8
61,2
75,4

102,9 112,3
95,6 137,7
-

17,6
15,8
17,6

27,8
24,4
27,8

40,5
35,4
40,5

67,8
61,2
75,4

102,9 112,3
95,6 137,7
-

60,2
70,5
-

Characteristic resistance
Cracked concrete

Non-cracked concrete
Anchor size
Tensile NRk
HST
HST-R
HST-HCR
Shear VRk
HST
HST-R
HST-HCR

M8

M10 M12 M16 M20 M24

M8

M10 M12 M16 M20 M24

[kN]
[kN]
[kN]

9,0
9,0
9,0

16,0
16,0
16,0

20,0
20,0
20,0

35,0
35,0
35,0

50,0
50,0
-

60,0
60,0
-

5,0
5,0
5,0

9,0
9,0
9,0

12,0
12,0
12,0

20,0
25,0
25,0

30,0
30,0
-

40,0
40,0
-

[kN]
[kN]
[kN]

14,0
13,0
13,0

23,5
20,0
20,0

35,0
30,0
30,0

55,0
50,0
55,0

84,0
60,0
-

94,0
80,0
-

14,0
13,0
13,0

23,5
20,0
20,0

35,0
30,0
30,0

55,0
50,0
53,5

84,0
60,0
-

94,0
80,0
-

M10 M12 M16 M20 M24

Design resistance
Cracked concrete

Non-cracked concrete
Anchor size
Tensile NRd
HST
HST-R
HST-HCR
Shear VRd
HST
HST-R
HST-HCR

M8

M10 M12 M16 M20 M24

M8

[kN]

5,0
6,0
6,0

10,7
10,7
10,7

13,3
13,3
13,3

23,3
23,3
23,3

33,3
33,3
-

40,0
40,0
-

2,8
3,3
3,3

6,0
6,0
6,0

8,0
8,0
8,0

13,3
16,7
16,7

20,0
20,0
-

26,7
26,7
-

[kN]
[kN]
[kN]

11,2
10,4
10,4

18,8
16,0
16,0

28,0
24,0
24,0

44,0
38,5
44,0

67,2
41,7
-

62,7
55,6
-

11,2
10,4
10,4

18,8
16,0
16,0

28,0
24,0
24,0

44,0
35,6
35,6

60,9
41,7
-

62,7
55,6
-

[kN]

Recommended loads
Non-cracked concrete

Cracked concrete

Anchor size
M8 M10 M12 M16 M20 M24 M8 M10 M12 M16 M20 M24
Tensile Nreca)
HST
[kN]
3,6 7,6 9,5 16,7 23,8 28,6 2,0 4,3 5,7 9,5 14,3 19,0
HST-R
[kN]
4,3 7,6 9,5 16,7 23,8 28,6 2,4 4,3 5,7 11,9 14,3 19,0
HST-HCR
[kN]
4,3 7,6 9,5 16,7
2,4 4,3 5,7 11,9
Shear Vrec a)
HST
[kN]
8,0 13,4 20,0 31,4 48,0 44,8 8,0 13,4 20,0 31,4 43,5 44,8
HST-R
[kN]
7,4 11,4 17,1 27,5 29,8 39,7 7,4 11,4 17,1 25,5 29,8 39,7
HST-HCR
[kN]
7,4 11,4 17,1 31,4
7,4 11,4 17,1 25,5
a) With overall partial safety factor for action J = 1,4. The partial safety factors for action depend on the type of
loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is
JG = 1,35 for permanent actions and JQ = 1,5 for variable actions.

6 / 2010

133

HST | Stud anchor

Materials
Mechanical properties of HST, HST-R, HST-HCR
Anchor size
Nominal
tensile
strength fuk
Yield strength
fyk

HST
HST-R
HST-HCR
HST
HST-R
HST-HCR

Stressed crosssection As
Moment of
resistance W
Char. bending
resistance
M0Rk,s

[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]

M8
800
720
800
640
575
640

M10
800
700
800
640
560
640

M12
800
700
800
640
560
640

M16
720
650
800
580
500
640

M20
700
650
560
450
-

M24
530
650
451
450
-

[mm]

36,6

58,0

84,3

157

245

353

[mm]

31,2

62,3

109,2

277,5

540,9

935,5

30
27
30

60
53
60

105
92
105

240
216
266

454
422
-

595
730
-

HST [Nm]
HST-R [Nm]
HST-HCR [Nm]

Material quality
Part
Bolt

HST
HST-R
HST-HCR

Material
Carbon steel, galvanised to min. 5 m
Stainless steel
High corrosion resistant steel

Anchor dimensions
Anchor size

M8

M10

M12

M16

M20

M24

tfix,min

[mm]

Maximum thickness of fixture

tfix,max

[mm]

195

200

200

235

305

330

Shaft diameter at the cone

dR

[mm]

5,5

7,2

8,5

11,6

14,6

17,4

Minimum length of the anchor

l1,min

[mm]

75

90

115

140

170

200

Maximum length of the anchor

l1,max

[mm]

260

280

295

350

450

500

Length of expansion sleeve

l2

[mm]

14,8

18,2

22,7

24,3

28,3

36

HST
M..

dR

Minimum thickness of fixture

l1

l2

Setting
Installation equipment
Anchor size
Rotary hammer
Other tools

134

M8

M10
M12
M16
M20
M24
TE2 TE16
TE40 TE70
hammer, torque wrench, blow out pump

6 / 2010

HST | Stud anchor

Setting instruction

For detailed information on installation see instruction for use given with the package of the product.
For technical data for anchors in diamond drilled holes please contact the Hilti Technical advisory service.

HST
M

Setting details: depth of drill hole h1 and effective anchorage depth hef

Tinst

hef
h1
Setting details HST, HST-R, HST-HCR
M8

M10

M12

M16

M20

M24

Nominal diameter of drill bit

do

[mm]

10

12

16

20

24

Cutting diameter of drill bit

dcut

[mm]

8,45

10,45

12,5

16,5

20,55

24,55

Depth of drill hole

h1

[mm]

65

80

95

115

140

170

Diameter of clearance hole in the


fixture

df

[mm]

12

14

18

22

26

Effective anchorage depth

hef

[mm]

47

60

70

82

101

125

a)

Torque moment

Tinst

[Nm]

20

40
45 b)

60

110

240

300

Width across

SW

[mm]

13

17

19

24

30

36

a) HST-R, HST-HCR: Tinst = 40 Nm


b) HST: Tinst = 45 Nm

6 / 2010