Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Emergency Model:P1120E
3P4W
Rating Range
1500RPM 50Hz
Standby:
kW
k VA
896
1120
Prime:
kW
k VA
816
1020
ALTERNATOR RATINGS
Alternator Model
HCI634J(STAMFORD)
50Hz
1500rpm
50Hz
1500rpm
Cont.H -125K/40
Cont.H -125K/40
380
400
415
440
380
400
415
190
200
208
220
190
200
208
220
230
240
254
220
230
240
Rating capacity(kVA)
1000
1030
1000
1000
1025
1025
1025
Rating power(kW)
800
824
800
800
820
820
820
Power efficiency(%)
95.0
95.1
95.3
95.4
95.1
95.1
95.1
Input power(kW)
842
866
839
839
863
863
863
Standby.H -125K/40
380
400
415
440
380
400
415
190
200
208
220
190
200
208
220
230
240
254
220
230
240
1075
1060
1060
1075
1075
Rating power(kW)
848
856
848
848
860
860
860
Power efficiency(%)
94.7
94.9
95.1
95.3
94.9
94.9
94.9
Input power(kW)
895
902
892
890
906
906
906
Rating capacity(kVA)
1060 1070
RATINGS: All three-phase units are rated at 0.8 power factor. Standby ratings : Standby
ratings apply to installations served by a reliable utility source. The standby rating is for
this rating. Ratings are in according with ISO-3046/1,BS 5514 ,AS 2789 , and DIN 6271.
Prime Power Ratings: Prime power ratings apply to installations where utility power is
unavailable or unreliable. At varying load, the number of generator set operating hours
is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in
accordance with IS0-8528/1, overload capacity in accordance with ISO-3046/1,BS 5514,
AS 2789, and DIN 6271. For limited running time and base load ratings, consult the
factory. The generator set manufacturer reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever.
GENERAL GUIDELINES FOR DERATION: Altitude: Derate 2.0% per 300m(984 ft.)
elevation above 1000m(3279 ft.) up to a maximum elevation of 2450m(8000 ft.).More than
2450m(8000ft), please contacts with us or our dealer seek the help.
Temperature: Derate 6.0% per 11
(20
) temperature above 40 (104
).
Standby.H -150K/40
ALTERNATOR
1500RPM 50Hz
Specification
Stator winding
Winding pitch
Winding leads
Maximum overspeed
Altitude
1.5%
Class H
IP23
The 2/3 pitch design avoids excessive neutral currents. With the
2/3 pitch and carefully selected pole and tooth designs,
ensuresvery low waveform distortion.
0.8
Double layer concentric
Two thirds
12
2250 Rev/min
Self excited machines do not
sustain a short circuit current
Type
Exciter type
Voltage regulator
Voltage regulation
Insulation
Protection
Rated power factor
DIESEL ENGINE
4008TAG2A diesel engines are manufactured by Perkins
Engines Company Limited(UK).
Engine Electrical
Application Data
Manufacturer
Number of cylinders
Cylinder arrangement
Induction system
Compression ratio
Bore
Negative
28V
40A
24V
PERKINS(UK)
7.5KW
8
In-line
120 rev/min
Battery voltage
12V
Cycle
Stroke
Cubic capacity
Direction of rotation
1500RPM 50Hz
EngineSpecifications
1500RPM 50Hz
Fuel
Turbocharged
13.6:1 nominal
160 mm (6.30in)
190mm (7.48 in)
30.561litres
Anti-clockwise viewed on flywheel
Fuel System
1500RPM 50Hz
Direct injection
Fuel injector
Fuel injector pressure
Firing order
1,4,7,6,8,5,2,3
1500RPM 50Hz
962KW
4270kg
Gear driven
660litres/hr
0.25%
Fixed
9.5 m/s
77 m3 /min
300kPa
2.5m
1500RPM 50Hz
Fuel consumption
1500RPM 50Hz
Electronic governor
Exhaust
Exhaust System
Maximum back pressure
Exhaust outlet size
Exhaust gas flow (max)
Exhaust gas temperature (max)
816mmH 2o
Standby power
286litre/hr
2 152mm
195 m 3/min
267litre/hr
485
Prime Power
226litre/hr
(905
Lubrication
Lubrication system
Total system
Sump minimum
Shutdown switch setting.
Normal oil temperature
175litre/hr
1500RPM 50Hz
Baseload Power
163litre/hr
153litres
127litres
1.93 bar falling
95-113
109litre/hr
59litre/hr
Application Data
Cooling System
Cooling System
1500RPM 50Hz
48 litres
With radiator
Coolant flow
Fan Diameter
149 litres
10 L/S
1400mm
Fan Type
Pusher
71-85 (160 - 185 )
Recommended coolant:
50% ethylene glycol with a corrosion inhibitor
(BS 6580 :1992 or ASTM D3306-89 or AS2108)
and 50% clean fresh water.
Protection:
Over Speed Shutdown.
Low Oil Pressure Shutdown.
High Engine Temp Shutdown.
Charger failure alarm.
Mains failure alarm.
Optional Under speed Protection.
DC Supply: 8 to 35 V Continuous.
CONTROLLERS
DC Supply: 8 to 35 V Continuous.
Paralleling System
Controller System
Accessories
Enclosed Unit
Miscellaneous Accessories
Sound Enclosure
Weather Enclosure (with enclosed critical silencer)
Weather Housing (with roof-mounted critical silencer)
Trailer(Causes the genset easily to move)
Open Unit
Exhaust Silencer, Critical kit
Open Style
Cooling System
Block Heater
(recommended for ambient temperatures below 0
Overall Size, L W H
)
mm
4790 2036
Weight(radiator model),net,Kg
2235
7850
Fuel System
Auxiliary Fuel Pump
Soundproof Style
Overall Size, L W H
Weight(radiator model),net,Kg
mm
12192 2438
2896
12450
Electrical System
Battery Charger, Equalize/Float Type
NOTE : This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.
DISTRIBUTED BY: