N0.
Parameters
3
4
5
HSDPA Parameters
Algorithm Switches
10
Transmission Management
11
Parameter ID
PowerOffsetPpm
Parameter Meaning
Power offset between the last access
preamble and message control part
Default Value
Signalling: -3 dB Signalling: -3 dB
Services: -2 dB
Services: -2 dB
ConstantValue
PowerRampStep
4
5
PreambleRetransMax
Mmax
8 times
8 times
20 times
8 times
2, that is, 2 dB
Current Value
Relevant Command
Level
Set: ADD PRACHTFC
Cell
Modify: The PRACH TFC needs to
be deleted before being reconfigured.
Set: ADD PRACHBASIC
Cell
Cell
DefaultConstantValue
MaxAllowedUlTxPower
MaxUlTxPowerForConv
MaxUlTxPowerForStr
MaxUlTxPowerForInt
MaxUlTxPowerForBac
RNC
Set or modify: SET FRC
Query: LST FRC
Cell
MaxAllowedUlTxPower
Set: ADD CELLSELRESEL
Query: LST CELLSELRESEL
Modify: MOD CELLSELRESEL
Service-Oriented Parameters
Set: ADD CELLCAC
Query: LST CELLCAC
Modify: MOD CELLCAC
RRCPROCSRBDELAY
RRC: 0
RRC: 0
HHO: 7
HHO: 7
267469637.xls
Cell
Parameter ID
RlMaxDlPwr
Parameter Meaning
Maximum downlink transmit power of
the radio link
Default Value
RlMinDlPwr
PCPICHPower
MaxPCPICHPower
MinPCPICHPower
Refer to the ta Refer to the table Maximum and minimum downlink transmi
Relevant Command
Set: ADD CELLRLPWR
Query: LST CELLRLPWR
Modify: MOD CELLRLPWR
267469637.xls
Level
Cell
267469637.xls
BACK
Parameter Name
Command
Content
Range
Physical
unit/step
0~99
none
Defaule Value
Current Value
1ST
implemen
ted Value
Inter-RAT Handover
Index number uniquely identifying the configuration
of the typical service parameters.
Content: index number identifying the configuration
of the typical traffic RAB.
Service parameter
index
ADD TYPRABBASIC
Service Handover
Indicator
Handover type.
Content: HO_TO_GSM_SHOULD_BE_PERFORM:
Handover to the 2Gnetwork is performed whenever
2G signals are available. HO_TO_GSM_SHOULD_NOT_BE_PERFORM:
Handover to the 2G network is performed when 3G HO_TO_GSM_SHOULD_BE_PERFOR
signals are weak but 2G signals are strong. M,
HO_TO_GSM_SHALL_NOT_BE_PERFORM:
HO_TO_GSM_SHOULD_NOT_BE_PE
ADD TYPRABBASIC
Handover to the 2G network is not performed even
RFORM,
when 3G signals are weak but 2G signals are
HO_TO_GSM_SHALL_NOT_BE_PERF
strong.
ORM
If the handover type is available from the service
properties assigned by the Core Network (CN),
handovers are performed in the way specified by the
CN. If the handover type is not specified by the CN,
handovers are performed in the way specified in the
typical traffic parameter.
none
ADD GSMCELL
none
none
GPRS
Required 2G
Capability
none
none
GSM/GPRS/
EDGE
Inter-RAT CS
handover switch
ON, OFF
none
OFF
ON
04/22/2015
HO_TO_GSM_S HO_TO_GSM_S
HOULD_NOT_B HOULD_NOT_B
E_PERFORM
E_PERFORM
685
267469637.xls
Inter-RAT PS
handover switch
ON, OFF
none
OFF
ON
- PERIODICAL_REPORTING:
periodical inter-RAT measurement
report - EVENT_TRIGGER: eventtriggered inter-RAT measurement report
none
PERIODICAL_R PERIODICAL_R
EPORTING
EPORTING
CPICH_Ec/No,CPICH_RSCP,BOTH
none
BOTH,CPICH_R
SCP
BOTH
CPICH_Ec/No,CPICH_RSCP
none
CPICH_RSCP
CPICH_RSCP
none
D3
2D2F Measure
Quantity
3A Measure
Quantity
04/22/2015
ADD
CELLINTERRATHOC
Inter-RAT measurement report mode.
OV/SET
INTERRATHOCOV
Measurement quantity used in coverage-based
inter-RAT measurement in event-2D- or event-2Ftriggered reporting mode.
- CPICH: Common Pilot Channel
ADD
- Ec/No: Signal-to-Noise Ratio - RSCP: Received
CELLINTERRATHOC Signal Code Power
OV/SET
- CPICH_Ec/No: to use the Ec/No measurement
INTERRATHOCOV
quantity for event 2D or event 2F measurement. The
physical unit is dB.
- CPICH_RSCP: to use the RSCP measurement
quantity for event 2D or event 2F measurement. The
physical unit is dBm.
Measurement quantity used in coverage-based
inter-RAT measurement in event-3A-triggered
reporting mode.
Content: - CPICH: Common Pilot Channel
ADD
- Ec/No: Signal-to-Noise Ratio - RSCP: Received
CELLINTERRATHOC Signal Code Power
OV/SET
- CPICH_Ec/No: to use the Ec/No measurement
INTERRATHOCOV
quantity for event 3A measurement. The physical
unit is dB.
- CPICH_RSCP: to use the RSCP measurement
quantity for event 3A measurement. The physical
unit is dBm.
ADD
CELLINTERRATHOC
OV/SET
INTERRATHOCOV
785
267469637.xls
none
D3
D3
0~20
0~2; step:
0.1
Inter-RAT CS
measure start
Ec/No THD[dB]
-24~0
dB
-14
-14
Inter-RAT PS
measure start
Ec/No THD[dB]
-24~0
dB
-15
-15
2D Event
04/22/2015
885
267469637.xls
Inter-RAT CS
measure start
RSCP THD[dBm]
-115~-25
dBm
-100
Inter-RAT PS
measure start
RSCP THD[dBm]
-115~-25
dBm
-110
-110
2D hysteresis[dB]
0~29
dB/0.5
2D event trigger
delay time[ms]
ADD
CELLINTERRATHOC
OV/SET
INTERRATHOCOV
ms
D320
D320
-90
2F event
04/22/2015
985
267469637.xls
-24~0
dB
-12
-12
-24~0
dB
-13
-13
Inter-RAT CS
measure stop
RSCP THD[dBm]
-115~-25
dBm
-97
-97
-85
Inter-RAT PS
measure stop
RSCP THD[dBm]
-115~-25
dBm
-107
-107
-85
04/22/2015
1085
267469637.xls
2F hysteresis[dB]
2F event trigger
delay time[ms]
ADD
CELLINTERRATHOC
OV/SET
INTERRATHOCOV
0~29
dB/0.5
ms
D1280
D1280
3A Event
Inter-RAT CS Used
frequency trigger
Ec/No THD[dB]
-24~0
dB
-12
-12
Inter-RAT PS Used
frequency trigger
Ec/No THD[dB]
-24~0
dB
-13
-13
04/22/2015
1185
267469637.xls
Inter-RAT CS Used
frequency trigger
RSCP THD[dBm]
-115~-25
dBm
-97
Inter-RAT PS Used
frequency trigger
RSCP THD[dBm]
-115~-25
dBm
-107
-107
Inter-RAT CS
handover decision
THD[dBm]
0~63
Physical
value
range:
-110~-48
(The value
1
correspon
ds to the
physical
value
-110, 2 to
-109, ...,
63 to -48.)
Physical
unit: dBm
16
Different cell
have different
setting
04/22/2015
1285
267469637.xls
Inter-RAT PS
handover decision
THD[dBm]
3A hysteresis[dB]
3A event trigger
delay time[ms]
ADD
CELLINTERRATHOC
OV/SET
INTERRATHOCOV
0~63
Physical
value
range:
-110~-48
(The value
1
correspon
ds to the
physical
value
-110, 2 to
-109, ...,
63 to -48.)
Physical
unit: dBm
16
0~15
Physical
value
range:
0~7.5,
step: 0.5
Physical
unit: dB
Physical
value
range: 0,
10, 20,
40, 60,
80, 100,
D0, D10, D20, D40, D60, D80, D100,
120, 160,
D120, D160, D200, D240, D320, D640,
200, 240,
D1280, D2560, D5000
320, 640,
1280,
2560,
5000
Physical
unit: ms
D0
Different cell
have different
setting
D0
3C Event
04/22/2015
1385
267469637.xls
Inter-RAT CS
handover decision
THD[dBm]
SET
INTERRATHONCOV/
ADD
CELLINTERRATHON
COV
Inter-RAT PS
handover decision
THD[dBm]
SET
INTERRATHONCOV/
ADD
CELLINTERRATHON
COV
04/22/2015
0 to 63
Physical
value
range:
-110 to
-48 (The
value 1
correspon
ds to the
physical
value
-110, 2 to
-109, ...,
63 to -48)
Physical
unit: dBm
21
21
14
0 to 63
Physical
value
range:
-110 to
-48 (The
value 1
correspon
ds to the
physical
value
-110, 2 to
-109, ...,
63 to -48)
Physical
unit: dBm
21
21
14
REQUIRED, NOT_REQUIRE
none
REQUIRED
REQUIRED
1485
267469637.xls
Inter-RAT period
report interval[ms]
NON_PERIODIC_REPORT, D250,
D500, D1000, D2000, D3000, D4000,
D6000, D8000, D12000, D16000,
D20000, D24000, D28000, D32000,
D64000
ms
D1000
D1000
Inter-RAT measure
timer length[s]
0~512
60
60
-50~50
dB
0~64000
ms
0~64000, 65535
ms
65535
65535
Cell individual
offset[dB]
ADD GSMNCELL
04/22/2015
1585
267469637.xls
Inter-RAT
hysteresis[dB]
ADD
CELLINTERRATHOC
OV/SET
INTERRATHOCOV
0~15
dB/0.5
1~16
times
16
16
0~65535
30
30
none
INTERFREQ
INTERFREQ
Value range:
COEXIST_MEAS_THD_CHOICE_INTE
RFREQ,
COEXIST_MEAS_THD_CHOICE_INTE
RRAT
COEXIST_MEAS_THD_CHOICE_INTE
InterFreq & InterRat
Type of event 2D/2F measurement thresholds when RFREQ: choosing the inter-frequency
coexist measure
ADD CELLHOCOMM inter-frequency and inter-RAT measurement coexist. oriented parameters as event 2D/2F
threshold choice
measurement thresholds for interfrequency measurement
COEXIST_MEAS_THD_CHOICE_INTE
RRAT: choosing the inter-RAT oriented
parameters as event 2D/2F
measurement thresholds for inter-RAT
measurement
none
04/22/2015
COEXIST_MEA COEXIST_MEA
S_THD_CHOIC S_THD_CHOIC
E_INTERFREQ E_INTERFREQ
1685
267469637.xls
04/22/2015
1785
267469637.xls
BACK
Handover
Parameters
Parameter Name
Parameter Meaning
Command
InterRATFilterCoef
2D2FFilterCoef
InterRATReportMod
e
WeightForUsedFreq
InterPeriodReportInterval
BSICVerify
2D2FMeasQuantity
Inter-RAT measurement quantity
3AMeasQuantity
InterRATCSThd2DRSCP
InterRATPSThd2DRSCP
InterRATCSThd2FRSCP
InterRATPSThd2FRSCP
For RNC
Set or modify: SET
INTERRATHOCOV
Query: LST INTERRATHOCOV
For Cell
InterRATCSThd2DEcN0
InterRATPSThd2DEcN0
InterRATCSThd2FEcN0
InterRATPSThd2FEcN0
Coverage-Based
Inter-RAT Handover InterRATCovHOCSThd
Management
Parameters
InterRATCovHOPSThd
Set: ADD
CELLINTERRATHOCOV
Query: LST
CELLINTERRATHOCOV
Modify: MOD
CELLINTERRATHOCOV
TrigTime2D
TrigTime2F
TrigTime3A
Hystfor3A
Hystfor2D
Hystfor2F
HystforInterRAT
04/22/2015
1885
267469637.xls
TimeToTrigForVerify
TimeToTrigForNonVerify
PenaltyTimeforInterRATHO
CellIndividalOffset
IRHOUsedFreqCSThdEcN0
InterRATMeasTime
Modify: MOD
CELLINTERRATHOCOV
Set: ADD CELLHOCOMM
CSServiceHOSwitch
Query: LST CELLHOCOMM
PSServiceHOSwitch
Modify: MOD CELLHOCOMM
InterRATFilterCoef
For RNC
Hystfor3C
Non CoverageBased Inter-RAT
Handover
Management
Parameters
TrigTime3C
Query: LST
INTERRATHONCOV
BSICVerify
InterRATNCovHOCSThd
InterRATNCovHOPSThd
PenaltyTimeforInterRATHO
InterRATHOAttempts
InterRATMeasTime
For Cell
Set: ADD
CELLINTERRATHONCOV
Query: LST
CELLINTERRATHONCOV
Modify: MOD
CELLINTERRATHONCOV
Non-Coverage-Based inter-RAT
handover judging thresholds
Penalty Time for inter-RAT handover
Inter-RAT handover max attempt times
Inter-RAT measure timer length
For Inter-RAT
Blind Handover
Management
Parameters
04/22/2015
Qrxlevmin
Qsearch_I
N/A
FDD_Qoffset
1985
N/A
FDD_Qmin
04/22/2015
267469637.xls
2085
267469637.xls
CK
Default Value
Current Value
D3
D3
Periodical_reporting
Periodical_reporting
Require
Require
2D2FMeasQuantity: BOTH
3AMeasQuantity: CPICH_RSCP
Level
2D2FMeasQuantity: BOTH
3AMeasQuantity:
CPICH_RSCP
InterRatCSThd2DRscp: -100
(dBm)
InterRatPSThd2DRscp: -110
(dBm)
InterRatCSThd2FRscp: -97
(dBm)
InterRATCSThd2DEcN0: -14
(dB)
InterRATCSThd2DEcN0: -14 (dB)
InterRATPSThd2DEcN0: -15 (dB)
InterRATCSThd2FEcN0: -12 (dB)
InterRATPSThd2DEcN0: -15
(dB)
RNC
Cell
InterRATCSThd2FEcN0: -12
(dB)
TRIGTIME2D: D320
TRIGTIME2D: D320
TRIGTIME2F: D1280
TRIGTIME2F: D1280
TRIGTIME3A: D0
TRIGTIME3A: D0
2D/2F/3A: 4 (2 dB)
2D/2F/3A: 4 (2 dB)
04/22/2015
2185
267469637.xls
0, that is, handover immediately
30 s
30 s
0 dB
0 dB
NCell
IRHOUsedFreqCsThdEcN0:
-12 (dB)
IRHOUsedFreqCsThdEcN0: -12 (dB)
IRHOUsedFreqPsThdEcN0: -13 (dB)
IRHOUsedFreqCsThdRscp: -97 (dBm)
IRHOUsedFreqPsThdEcN0:
-13 (dB)
IRHOUsedFreqCsThdRscp:
-97 (dBm)
RNC
Cell
IRHOUsedFreqPsThdRscp:
-107 (dBm)
60 s
60 s
OFF
OFF
D3
D3
0 dB
0 dB
Required
Required
CELL
RNC
21, that is, -90 dBm
30 s
30 s
16 times
16 times
60 s
60 s
Cell
NCell
GSM
0 dB
0 dB
04/22/2015
2285
267469637.xls
GSM
0 dB
0 dB
04/22/2015
2385
BACK
Parameter ID
1 UlTotalEqUserNum
2 DlTotalEqUserNum
3 UlConvAMRThd
4 UlConvNonAMRThd
5 DlConvAMRThd
6 DlConvNonAMRThd
7
8
9
10
11
12
No.
UlOtherThd
DlOtherThd
UlHOThd
DlHOThd
DLCELLTOTALTHD
ULCCHLoadFactor
DLCCHLoadRSRVCoeff
Parameter ID
1 UlHoCeResvSf
2 DlHoCeCodeResvSf
Parameter ID
Parameter Meaning
Uplink total equivalent user number
Downlink total nonhsdpa equivalent user
number
AMR voice uplink threshold for
conversation service
Non AMR voice uplink threshold of
conversation service
AMR voice downlink threshold for
conversation service
Non AMR Voice downlink threshold of
conversation service
Uplink threshold for other services
Downlink threshold for other services
Uplink handover admission threshold
Downlink handover admission threshold
Downlink total power threshold
Uplink and downlink common channel
load reserved coefficients
Code and Credit admission control parameters
Parameter Meaning
Uplink handover credit reserved SF
Downlink handover credit and channel
code resource reserved SF
GeneralCommC
hFactor
CMBCommChF
actor
MBMSCommC
hFactor
SRBFactor
TelephonyFacto
r
R99ConvFactor
R99StreamFact
or
R99InterFactor
R99BkgrndFact
or
HsdpaStreamFa
ctor
HsdpaInterFacto
r
HsdpaBkgrndFa
ctor
HsupaStreamFa
ctor
HsupaInterFacto
r
HsupaBkgrndFa
ctor
No.
Parameter ID
1 ULBETraffInitBitRate
DLBETraffInitBitRate
70%
100%
100%
50%
70%
100%
100%
50%
50%
100%
100%
100%
100%
100%
100%
2 IU_Qos_Neg_Switch
RAB_Downsizing_Switch
QueueAlgoSwitch
PeemptAlgoSwitch
BACK
Current Value
80
80
75%
75%
75%
75%
80%
80%
80%
80%
60%
75%
80%
85%
90%
0
60%
75%
80%
85%
90%
0
Relevant Command
Set: ADD CELLCAC
Query: LST CELLCAC
Modify: MOD CELLCAC
Relevant
Command
Set the
parameters
through ADD
AAL2PATH /
ADD IPPATH;
modify them
through MOD
AAL2PATH /
MOD IPPATH;
Level
Cell
Current Value
0
Level
Cell
Query them
through LST
AAL2PATH /
DSP
AAL2PATH /
LST IPPATH /
DSP IPPATH.
Set this
parameter
through ADD
NODEBALGO
PARA, modify
it through MOD
NODEBALGO
PARA, and
query it through
LST
NODEBALGO
PARA
70%
100%
100%
50%
70%
100%
100%
50%
50%
100%
100%
100%
100%
100%
100%
RAB_DOWNSI RAB_DOWNSI
ZING_SWITCH ZING_SWITCH Set or modify: SET CORR
:1
:1
QUEUEALGOS
WITCH: OFF
PREEMPTALG
OSWITC: OFF
QUEUEALGOS
WITCH: OFF Query: LST CORRMALGOSWI
PREEMPTALG QueueAlgoSwitch and
OSWITC: OFF PeemptAlgoSwitch
Set or modify: SET QUEU
Query: LST QUEUEPREEMPT
BACK
No.
Parameter ID
1 ULLDR
DLLDR
12 IubCongCtrlSwitch
No.
1
3
4
5
No.
OFF
OFF
Parameter ID
1 UlLdrFirstAction
ULLDRFirstAc
tion and
DLLDRSecond
Action:
INTERFREQL
DHO
ULLDRFirstAc
tion and
DLLDRSecond
Action:
INTERFREQL
DHO
UlLdrThirdAction
ULLDRSecond ULLDRSecond
Action and
Action and
DLLDRTHIRD DLLDRTHIRD
Action:
Action:
BERATERED BERATERED
UlLdrFourthAction
Others:
NOACT
UlLdrFifthAction
UlLdrSixthAction
UlLdrSeventhAction
UlLdrEighthAction
DlLdrFirstAction
DLLDRSecondAction
DLLDRThirdAction
DLLDRFourthAction
DLLDRFifthAction
DlLdrSixthAction
DlLdrSeventhAction
DlLdrEighthAction
DlLdrNinthAction
DlLdrTenthAction
2 ULLDRBERateReductio Number of users processed ULLDRCSInte ULLDRCSInte
nRabNum
by uplink/downlink LDR rRATSHOULD rRATSHOULD
action
BEHOUserNu BEHOUserNu
m,
m,
ULLDRCSInte ULLDRCSInte
rRATSHOULD rRATSHOULD
NOTBEHOUse NOTBEHOUse
rNum and
rNum and
ULLDRAMRR ULLDRAMRR
ATEREDUCTI ATEREDUCTI
ONRABNUM ONRABNUM
are set to 3 by are set to 3 by
default; others default; others
are set to 1 by are set to 1 by
default.
default.
ULLDRPSRTQosReneg
RabNum
ULLDRCSInterRATSH
OULDBEHOUserNum
ULLDRCSInterRATSH
OULDNOTBEHOUserN
um
ULLDRPSInterRATSH
OULDBEHOUserNum
ULLDRPSInterRATSH
OULDNOTBEHOUserN
um
ULLDRAMRRATERED
UCTIONRABNUM
DLLDRBERateReductio
nRabNum
DLLDRPSRTQosReneg
RabNum
DLLDRCSInterRATSH
OULDBEHOUserNum
DLLDRCSInterRATSH
OULDNOTBEHOUserN
um
DLLDRPSInterRATSH
OULDBEHOUserNum
DLLDRPSInterRATSH
OULDNOTBEHOUserN
um
MAXUSERNUMCODE
ADJ
DLLDRCSInte
rRATSHOULD
BEHOUserNu
m,
DLLDRCSInte
rRATSHOULD
NOTBEHOUse
rNum and
DLLDRAMRR
ATEREDUCTI
ONRABNUM
are set to 3 by
default; others
are set to 1 by
default.
DLLDRCSInte
rRATSHOULD
BEHOUserNu
m,
DLLDRCSInte
rRATSHOULD
NOTBEHOUse
rNum and
DLLDRAMRR
ATEREDUCTI
ONRABNUM
are set to 3 by
default; others
are set to 1 by
default.
DLLDRAMRRATERED
UCTIONRABNUM
3 UlInterFreqHoBWThd UL or DL inter-frequency 200k bps
cell load handover
DlInterFreqHoBWThd maximum bound width
4 LdrPeriodTimerLen
LDR period timer length 10 s
5 IubCongCtrlTimerLen
6 LdrCodePriUseInd
No.
200k bps
10 s
60 s
60 s
Parameter ID
1 ULOLC
DLOLC
Parameter Meaning
Uplink/Downlink OLC
algorithm switch
2 OlcPeriodTimerLen
3 UlOlcTrigThd
UlOlcTrigThd:
95%
DlOlcTrigThd:
95%
UlOlcRelThd:
80%
DlOlcRelThd:
80%
3 times
DlOlcTrigThd
UlOlcRelThd
DlOlcRelThd
4 UlOlcFTFRstrctTimes
DlOlcFTFRstrctTimes
5 UlOlcFTFRstrctRabNum
DlOlcFTFRstrctRabNum
6 RateRstrctTimerLen
RateRecoverTimerLen
7 RateRstrctCoef
8 UlOlcTraffRelRabNum
UlOlcTrigThd:
95%
DlOlcTrigThd:
95%
UlOlcRelThd:
80%
DlOlcRelThd:
80%
3 times
3
RateRstrctTime RateRstrctTime
rLen: 3000 (3 rLen: 3000 (3
s)
s)
RateRecoverTi RateRecoverTi
merLen: 5000 merLen: 5000
(5 s)
(5 s)
OLC fast TF restrict data 68, that is, 68% 68, that is, 68%
rate restrict coefficient
Uplink or downlink release
0
0
RAB number
8
DlOlcTraffRelRabNum
algorithm parameters
Relevant Command
Level
Set: ADD CELLALGOSWITCH \NBMSwitch
Cell
Query: LST CELLALGOSWITCH
Modify: MOD CELLALGOSWITCH \NBMSwitch
Set this parameter through ADD NODEBALGOPARA,
modify it through MOD NODEBALGOPARA, and
NodeB
query it through LST NODEBALGOPARA
algorithm parameters
Relevant Command
Set: ADD CELLLDM
Level
Cell
PATH
algorithm parameters
Relevant Command
Level
Cell
Cell
RNC
Cell
ol parameters
Relevant Command
Level
Set: ADD CELLALGOSWITCH \NBMLdcAlgoSwitch
Cell
Query: LST CELLALGOSWITCH
Modify: MOD CELLALGOSWITCH \NBMLdcAlgoSwitch
Set or modify: SET LDCPERIOD
RNC
Query: LST LDCPERIOD
Cell
Set: ADD CELLLDM
Query: LST CELLLDM
Modify: MOD CELLLDM
BACK
No.
Parameter ID
1 BeBitRateThd
Parameter Meaning
BE service handover rate
threshold
2 UlPsBeGuarRate
DlPsBeGuarRate
3 UlBeTraffDecThs
DlBeTraffDecThs
4 DlStrThsonHsdpa
DL streaming threshold on
HSDPA
5 DlBeTraffThsOnHsdpa DL BE traffic threshold on
HSDPA
6 UlBeTraffThsOnHsupa UL BE traffic threshold on
HSUPA
7 UlStrThsOnHsupa
UL streaming traffic
threshold on HSUPA
No.
1
2
3
4
5
Parameter ID
Event4aThd
Event4bThd
TimetoTrigger4A
TimetoTrigger4B
PendingTime4A
6 PendingTime4B
7 UlDcccRateThd
DlDcccRateThd
8 UlMidRateThd
DlMidRateThd
9 UlRateAdjLevel
Parameter Meaning
Traffic upper threshold
Traffic lower threshold
Time to trigger event 4A
Time to Trigger event 4B
Pending time after trigger
event 4A
Pending time after trigger
D4000, that is, 4 s
event 4B
Uplink and downlink DCCC D64 (64 Kbit/s)
rate thresholds
Uplink and downlink middle D128 (128 Kbit/s)
rate thresholds
Uplink and downlink rate
adjust level
2_Rates
9
DlRateAdjLevel
10 LittleRateThd
No.
No.
2_Rates
D64, that is, 64 Kbit/s
Parameter ID
1 EventEaThd
Parameter Meaning
Event Ea relative threshold
2 EventEbThd
3 UlFullCvrRate
4 DlFullCvrRate
Parameter ID
1 DtoFStateTransTimer
2 D2F2PTvmThd
3 FtoPStateTransTimer
4 CellReSelectTimer
5 FtoDTvmThd
6 FtoDTvmTimeToTrig
No.
1
2
3
4
5
6
Parameter ID
PSINACTTMRFORIN
T
PROTECTTMRFORI
NT
PSINACTTMRFORB
AC
PROTECTTMRFORB
AC
PSINACTTMRFORI
MS
PROTECTTMRFORI
MS
Parameter Meaning
DCH to FACH state
transition timer
DCH to FACH and FACH to D64 (64 bytes)
PCH state transition traffic
4B threshold
FACH to PCH state
transition timer
Cell Reselection timer
FACH to DCH traffic report
threshold
FACH-to-DCH traffic timeto-trigger
180 s
180 s
D1024 (1024 bytes)
D240 (240 ms)
Parameter Meaning
Interactive service T1
PS inactive parameters
Default Value
20 s
Interactive service T2
20 s
Background service T1
20 s
Background service T2
20 s
IMS service T1
20 s
IMS service T2
20 s
No.
1
2
3
4
5
6
7
8
9
10
Parameter ID
TimeToMoniter
MoniterPrd
ReTransRatioFilterCoe
f
EventAThred
TimeToTriggerA
PendingTimeA
ReTransReportPeriod
EventBThred
TimeToTriggerB
PendingTimeB
Parameter Meaning
Time to start Re-TX monitor
Re-Tx monitor period
Retransmission filter
coefficient
Event A threshold
Event A time to trigger
Event A pending time after
trigger
Event A report period
Event B threshold
Event B time to trigger
Event B pending time after
trigger
Default Value
5000 ms
1000 ms
1
160, that is 16%
2
1
50 ms
80, that is 8%
14
1
BACK
Relevant Command
Set or Modify: SET HOCOMM
Query: LST HOCOMM
For RNC level
Set or modify: SET DCCC
Query: LST DCCC
For Cell level
Set: ADD CELLDCCC
Query: LST CELLDCCC
Modify: MOD CELLDCCC
For RNC level
Set or modify: SET FRC
Query: LST FRC
For Cell level
Set: ADD CELLFRC
Query: LST CELLFRC
Modify: MOD CELLFRC
Set or modify: SET FRC
Level
RNC
RNC/
Cell
RNC
el configuration parameters
Current Value
Relevant Command
D1024, that is, 1024 bytes Set: ADD TYPRABDCCCMC
Query: LST TYPRAB
D128, that is, 128 bytes
Modify: MOD TYPRABDCCCMC
D240, that is, 240 ms
D2560, that is, 2.56 s
D4000, that is, 4 s
Level
RNC
RNC
RNC
3_Rates
D64, that is, 64 Kbit/s
ability parameters
Current Value
2 (1 dB)
2 (1 dB)
64 Kbit/s
32 Kbit/s
ansfer parameters
Current Value
180 s
Relevant Command
For RNC level
Set or modify: SET DCCC
Query: LST DCCC
For cell level
Set: ADD CELLDCCC
Query: LST CELLDCCC
Relevant Command
Set or Modify: SET UESTATETRANS
Level
RNC/Cell
Level
RNC
active parameters
Current Value
20 s
20 s
20 s
20 s
20 s
20 s
Relevant Command
Set or modify: SET PSINACTTIMER
Query: LST PSINACTTIMER
Level
RNC
Current Value
5000 ms
1000 ms
1
160, that is 16%
2
1
50 ms
80, that is 8%
14
1
Relevant Command
Set: ADD TYPRABRLC
Query: LST TYPRAB
Modify: MOD TYPRABRLC
Level
Cell
BACK
No.
1
Parameter ID
MaxTxPower
PCPICHPower
PSCHPower
SSCHPower
BCHPower
MaxFachPower
Maximum FACH
transmit power
PCHPower
PICHPowerOffset
-3 dB
AICHPowerOffset
-6 dB
No.
1
Parameter ID
DRXCycleLenCoef
Paging parameters
Parameter Meaning Default Value
Paging cycle coefficient 6
MaccPageRepeatTimes
Parameter ID
Parameter Meaning
Number of page
retransmit
No.
1
Parameter ID
NInsyncInd
Synchronization parameters
Default Value
5
NOutsyncInd
TRLFailure
N312
T312
N313
N315
T313
T300
N300
Parameter ID
T314
T315
T302
N302
Parameter ID
T3212
No.
Parameter Meaning
Timer T314
Timer T315
Timer T302
Counter N302
Parameter Meaning
Number of successive
in-sync indications
Number of successive
out-of-sync indications
Radio link failure timer
duration
N312 and T312
N313, N315, and T313
Default Value
20s
30s
2s
3
Parameter Meaning
Default Value
Periodic location update 10, that is, 1 hour
timer
Parameter ID
Parameter Meaning
50
50 (5 s)
N312: D1
T312: 6 s
N313: D50
N315: D1
T313: 3 s
Cell update parameters
Relative Command
Set or modify: SET CONNMO
Query: LST CONNMODETIMER
1 ARP1Priority,
ARP2Priority,
ARP3Priority,
ARP4Priority,
ARP5Priority,
ARP6Priority,
ARP7Priority,
ARP8Priority,
ARP9Priority,
ARP10Priority,
ARP11Priority,
ARP12Priority,
ARP13Priority,
ARP14Priority
User priority of
allocation/retention
priority 1~14
None.
2 PriorityReference
Integrated priority
configured reference
Indicator of carrier type
priority
ARP
3 CarrierTypePriorInd
DCH
CK
stribution parameters
Current Value
460, that is, 46 dBm
Indoor sites :330
Macro sites:350
-50, that is, -5 dB
-7
-6
Relevant Command
ADD CELLSETUP
MOD CELLSETUP
ADD PCPICH
LST PCPICH
MOD CELL
PSCHPower
ADD PSCH
LST PSCH
MOD CELL
SSCHPower
ADD SSCH
LST SSCH
MOD CELL
ADD BCH
LST BCH
MOD CELL
ADD FACH
LST FACH
MOD SCCPCH
ADD PCH
LST PCH
MOD SCCPCH
ADD CHPWROFFSET
LST PICH
MOD PICHPWROFFSET
ADD CHPWROFFSET
LST AICH
MOD AICHPWROFFSET
Level
Cell
FACH
Cell
arameters
Current Value
6
parameters
Current Value
Relevant Command
Level
Set or modify: SET FRC or MOD RNC
CNDOMAIN
Query: LST FRC or LST
CNDOMAIN
Set or modify: SET DPUCFGDAT
Query: LST DPUCFGDATA
Level
T300: D2000 (2 s)
N300: 3
on parameters
Current Value
5
50
50 (5 s)
N312: D1
T312: 6 s
N313: D50
N315: D1
T313: 3 s
RNC
Relevant Command
Set: ADD CELLSETUP
Level
Cell
meters
Current Value
20s
30s
2s
3
Level
RNC
rameters
Current Value
10, that is, 1 hour
ated parameters
Current Value
Level
RNC
Relevant Command
Level
ARP1PRIORITY=GOLD,
ARP2PRIORITY=GOLD,
ARP3PRIORITY=GOLD,
ARP4PRIORITY=GOLD,
ARP5PRIORITY=GOLD,
ARP6PRIORITY=SILVER,
ARP7PRIORITY=SILVER,
ARP8PRIORITY=SILVER,
ARP9PRIORITY=SILVER, Set or modify: SET USERPRIOR
ARP10PRIORITY=SILVER,
ARP11PRIORITY=COPPER,
ARP12PRIORITY=COPPER
,
ARP13PRIORITY=COPPER
,
ARP14PRIORITY=COPPER
ARP
NONE
BACK
No.
1
24/15
12\15
9\15
24/15
7 CQIPO
CQIPOforSHO
8 CQIReF
CQIReFforSHO
9 CQIFbCk
CQIFbCkforSHO
Parameter ID
1 HspaPower
No.
Parameter ID
ACKPO1
ACKPO2
ACKPO3
ACKPO1forSHO
ACKPO2forSHO
ACKPO3forSHO
NACKPO1
NACKPO2
NACKPO3
NACKPO1forSHO
NACKPO2forSHO
NACKPO3forSHO
ACKNACKReF1
ACKNACKReF2
ACKNACKReF3
ACKNACKReFforSHO
Parameter ID
Parameter Meaning
No.
Parameter ID
1 AllocCodeMode
2 HsPdschCodeNum
3 HsPdschMaxCodeNum
4 HsPdschMinCodeNum
5 HsScchCodeNum
100%
No.
Parameter ID
1 HRetryTimerLen
2 D2HIntraHoTimerLen
2 (2 s)
5 (5 s)
14 (14 s)
1
No.
Parameter ID
Parameter Meaning
1 NodeBHsdpaMaxUserNu Maximum HSDPA users
m
of NodeB
Default Value
3840
2 UlHsDpcchRsvdFactor
3 HsdpaStrmPBRThd
4 HsdpaBePBRThd
5 MaxHSDSCHUserNum
UL HS-DPCCH reserve
factor
HSDPA streaming PBR
threshold
HSDPA best effort PBR
threshold
Max number of users
supported by HSDPA
channel
70%
30%
64
CK
control parameters
Current Value
24/15
12\15
9\15
24/15
Relevant Command
Set: ADD CELLHSDPCCH
Query: LST CELLHSDPCCH
Modify: MOD CELLHSDPCCH
Level
Cell
Relevant Command
Set: ADD CELLHSDPA
Query: LST CELLHSDPA
Level
Cell
24/15
12\15
9\15
24/15
1
2
3
1
24/15
1
D2 (2 ms)
Level
100%
Cell
Level
Cell
5
4
ment parameters
Current Value
0 (0 s)
Level
RNC
Relevant Command
Level
Set or modify: SET COIFTIMER RNC
Query: LST COIFTIMER
Set or modify:SET HOCOMM
Query: LST HOCOMM
14 (14 s)
1
ol algorithm parameters
Current Value
3840
0
70%
30%
64
Relevant Command
Set: ADD NODEBALGOPARA
Query: LST NODEBALGOPARA
Modify: MOD NODEBALGOPARA
Set: ADD CELLCAC
Query: LST CELLCAC
Modify: MOD CELLCAC
Level
NodeB
Cell
BACK
Channel algorithm switches
No.
Switch ID
Switch Meaning
Default Setting
1 AMR_TWO_CODCH_SWITCH Switch for two DCHs
OFF
configuration by AMR
2 AMRC_SWITCH
OFF
OFF
4 DCCC_SWITCH
ON
ON
ON
7 FRC_FP_MODE_SWITCH
ON
FP mode switch
OFF
OFF
11 IGNORE_RLC_CAP_SWITCH
ON
12 IMS_SUPPORT_ACTIVATION
ON
13 IU_QOS_NEG_SWITCH
14 IU_QOS_RENEG_SWITCH
15 IUB_OVERBOOKING_SWITC
H
OFF
16 IUUP_V2_SPT_SWITCH
OFF
OFF
OFF
18 MULTI_RAB_SWITCH
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
3 FP_MUTI_RLS_IND_SWITCH
ON
4 INNER_LOOP_DL_LMTED_P
WR_INC_SWITCH
5 SIG_DCH_OLPC_SWITCH
Signaling transmission
OFF
participating in the outer loop
power control switch for
multiple DCHs.
6 OLPC_SWITCH
ON
7 OLPC_UL_SIR_ERR_REL_SWI
TCH
8 RL_RECFG_SIR_TARGET_CA
RRY_SWITCH
OFF
OFF
OFF
OFF
8 HSUPA_TTI_2MS_SWITCH
OFF
9 HSUPA_DCCC_SWITCH
OFF
OFF
No.
Switch
ID
2 DRD_SWITCH
3 HSDPA_DRD_SWITCH
OFF
4 RAB_DCCC_DRD_SWITCH
OFF
Switch ID
1 COMB_SERV_DRD_SWITCH
OFF
6 HSUPA_DRD_SWITCH
OFF
7 RAB_SETUP_DRD_SWITCH
ON
ON
ON
Switch Meaning
Description
ON
OFF
Control HSDPA
admission control
algorithm.
OFF
Control HSDPA
HS-DSCH
Required Power
measurement.
OFF
Control HSDPA
HS-DSCH
Provided Bit Rate
measurement.
OFF
Control HSUPA
admission control
algorithm.
OFF
Control MBMS
admission control
algorithm.
DOFFC
ON
Default DPCH
offset
configuration
algorithm.
OFF
It is also named
cell breathing
algorithm. Based
on the cell load,
this algorithm
changes the pilot
power of the cell
to control the
load between
intra-frequency
cells.
PUC
OFF
ULOLC
DLOLC
OFF
ULLDR
OFF
DLLDR
OFF
OFF
Specifies whether
condition to
trigger load
control uses
event
measurement
alone or infers
from the period
measurement
report.
OFF
OFF
ALGORITHM
_REQUIRED:
Always reset
the MAC-hs no
matter the cells
in question are
in the same
NodeB or not.
ALGORITHM
_DEPEND_O
N_LCG: Reset
the MAC-hs
only when the
cells in
question are in
the different
local cell
group.
BACK
orithm switches
Current Value
Description
OFF
When it is checked, the AMR voice call with the bit rate
of 7.95 Kbit/s or less than that is allocated for two CoDCHs. Otherwise, it is allocated for three DCHs.
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
algorithm switches
Current Value
Description
OFF
When it is checked, the BLER target value comes from
the BLER target value of the AMR modes specified in
the AMRC parameter table. Otherwise, it comes from
the BLER target value specified in TYPRAB.
ON
ON
OFF
OFF
ON
OFF
ON
ithm switches
Current Value
Description
OFF
When it is checked, UE RRC state transitions to
CELL_FACH for the DCCC algorithm of HSDPA
services are allowed in the RNC.
When the RAB on HS-DSCH is BE service,
the PS_BE_STATE_TRANS_SWITCH is required to
be checked simultaneously.
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ithm switches
Current Value
Description
OFF
Only when this switch is on, can DRD be done if
combination service needs retry.
OFF
This is the general DRD algorithm switch, only when
this switch is on, can the other DRD sub-switches be
on.
OFF
OFF
OFF
OFF
ON
ON
ON
Current Value
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ALGORITHM_
DEPEND_ON_L
CG
BACK
No.
Parameter ID
Parameter Meaning
1 AAL2PATHT
AAL2PATH type
2 PCR
SCR
MCR
3 UT
4 IPPATH
5 PHB
Per-Hop behavior
ANY
NRT
BACK
NRT
ANY
Relevant Command
Set: ADD AAL2PATH
Query: LST AAL2PATH or DSP AAL2PATH
Modify: MOD AAL2PATH
Set: ADD ATMTRF
Query: LST ATMTRF
BACK
No.
No.
Parameter ID
1 RSCALLOCM
2 SM
3 MXRETRAN
4 PWRMGN
5 SCCHPWRCM
6 SCCHPWR
EPF
4
5 (5%)
0 (adaptive power control
based on CQI)
28 (dB), step is 0.25
7 SCCHFER
8 IBLER
9 RSCLMSW
10
11
12
13
DYNCODESW
16QAMSW
CQIFA
SPIGBR
14 SPIWEIGHT
15 SPIRSCRATIO
No.
Parameter ID
OPEN
OPEN
OPEN
0 (no filter)
See the table
1 RADIUS
Cell radius
29 km
2 HORAD
0m
BACK
ntrol parameters
Current Value
AUTO_ADJUST_
FLOW_CTRLpath
0.10%
4 (8 ms)
ng algorithm parameters
Current Value
0
EPF
4
5 (5%)
0 (adaptive power control
based on CQI)
28 (dB), step is 0.25
Relevant Command
Set the parameter through SET
HSDPAFLOWCTRLPARA (BTS3812E,
BTS3812A, BTS3812AE,
BBU3806,BBU3806C), and query it through
LST HSDPAFLOWCTRLPARA (BTS3812E,
BTS3812A, BTS3812AE, BBU3806,
BBU3806C).
Relevant Command
Set the parameter through SET MACHSPARA
(BTS3812E, BTS3812A, BTS3812AE,
BBU3806, BBU3806C), and query it through
LST MACHSPARA (BTS3812E, BTS3812A,
BTS3812AE, BBU3806, BBU3806C).
OPEN
OPEN
OPEN
0 (no filter)
See the table
See the table
See the table
ment parameters
Current Value
Level
Cell
Relevant Command
2km
0m