Sei sulla pagina 1di 72

Contents

Designer and manufacturer


for healthcare applications

Vacuum pumps and side channel vacuum pumps


2

Oil-free technology plants


.Automatic vacuum plants.
MINIVAC 1 / MINIVAC 2 / MINIVAC 3 - Ps or Arica
HOSPIVAC 2 and 3 - Arica

4
6

.Oil-less piston vacuum pumps.


PS

40

.Oil-free rotary vane vacuum pumps.


ARICA

42

.Claw vacuum pumps.


SIRELLA

44

.Automatic vacuum plants.


HOSPIVAC V3 Sirella
HOSPIVAC G Sirella

8
10

.Side channel vacuum pumps.


KAV

46

.Anaesthetic waste gas scavenging systems.


ANAESTIVAC 1 and ANAESTIVAC 2

12

.Lubricated rotary vane vacuum pumps.


EVISA MV

48

.Liquid ring vacuum pumps.


ANTIGUA

52

.Bacterial filtrations.
FDxxxS : simple filtration without by-pass
FDxxxB : simple filtration with by-pass
FDxxxDP : parallel duplex filtration
Bacterial filtrations and protection pots

54
55
55
56

Lubricated technology plants


.Automatic vacuum plants.
HOSPIVAC 1
HOSPIVAC 2
HOSPIVAC 3
HOSPIVAC V3
HOSPIVAC V4 / HOSPIVAC V5 / HOSPIVAC V6
HOSPIVAC G
HOSPIVAC C

14
16
18
20
22
24
28

.Control and regulation.


Control and regulation devices for vacuum

58

.Accessories.
Liquid traps
"SPIREACIER" special hoses for vacuum
Vertical vacuum receivers

61
62
63

.MIL'S : Services.a
Services
Dimensioning calculation and conversion tables
Useful formulae
General conditions of sale and guarantee

64
65
66
68

Liquid ring technology plants


.Liquid ring vacuum plants for laboratories.
LABOVAC 1
LABOVAC 2

30
32

Emergency and back-up systems


.Emergency automatic vacuum plants.
MAVO Emergency station
Mobile MINIVAC 1 Evisa
SVI Independent Vacuum System
EOLVAC

34
36
37
38

Main office

Entrance hall

Our company

Machining

MIL'S, French vacuum pumps


manufacturer, was founded in 1926
and currently employs 90 people on
two sites in the outskirts of Lyon
and one sales office in the outskirts
of Paris.
The company operates over 10 000
sq.m of manufacturing floor space.
From design, through to sale, our
understanding and control of the
processes involved enables us to
offer a high quality product, using :
State-of-the-art computer
assisted design software

Design office

NC-plant and equipment


and several assembly facilities
Product packaging techniques
devised in-house
A dynamic, solutions-oriented
sales force
Check room

Field service engineers


and maintenance contracts
for your plant and equipment
Our customer training
centre to transfer in depth
knowledge of our products
and their uses.
Testing room

Designer and manufacturer


for healthcare applications

anaesthesia
Our products

resuscitation

emergency

From simple vacuum pump or


compressor to fully integrated
vacuum, oxygen and medicinal air
systems, MIL'S is proposing a wide
range of possibilities developped
for your specific applications
We have been specialised in medical
vacuum and air for many years and
can boast a satisfied customer
base, world-wide of over 3 500
healthcare facilities operating.
Our medical range, meeting 2007/47
directive, carries the CE-mark

neonatalogy

surgery
sterilisation

MINIVAC
Oil-free technology
MINIVAC 3 ARICA C2020
Compact and independent vacuum plant
Oil-less piston vacuum pumps (PS)
or oil-free rotary vane vacuum pumps (ARICA)
Regulation by mechanical vacuum switch for MINIVAC 1
Regulation by MILLENIUM or CYCLIC 2020 for MINIVAC 2 and 3
Receiver : 70 litres
Inlet bacterial filtration
Set of suction and exhaust hoses
Ready-to-run plants
Fit to NF EN ISO 7396-1 standard
Range complying with
2007/47/CE directive

MINIVAC 1 2 3 (PS) oil-less piston vacuum pumps


Characteristics
For more details about PS Pumps, please report to page 40.
MINIVAC PS
Oil-less piston pumps
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC

1
1
2
2
3
3

PS
PS
PS
PS
PS
PS

7V
12V
7V
12V
7V
12V

NOMINAL CAPACITY
m.h-1

POWER
kW

50 Hz

60 Hz

50 Hz

60 Hz

6.4
10.0
2 x 6.4
2 x 10.0
3 x 6.4
3 x 10.0

7.7
12.0
2 x 7.7
2 x 12.0
3 x 7.7
3 x 12.0

0.25
0.36
2 x 0.25
2 x 0.36
3 x 0.25
3 x 0.36

0,30
0,43
2 x 0.30
2 x 0.43
3 x 0.30
3 x 0.43

RECEIVER
CAPACITY FILTRATION
L
70
70
70
70
70
70

FD 30 B
FD 30 B
FD 30 B
FD 30 B
FD 60 DP
FD 60 DP

NOISE
LEVEL
dB(A)

WEIGHT

57
57
57
57
57
57

40
40
90
90
100
100

kg

MINIVAC 1 2 3 (ARICA) oil-free rotary vane vacuum pumps


Characteristics
For more details about ARICA Pumps, please report to page 42.

MINIVAC ARICA
Oil-free rotary vane vacuum pumps
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC
MINIVAC

1
1
1
2
2
2
3
3
3

16V
26V
40V
16V
26V
40V
16V
26V
40V

NOMINAL CAPACITY
m.h-1

POWER
KW

50 Hz

60 Hz

50 Hz

60 Hz

16
25
40
2 x 16
2 x 25
2 x 40
3 x 16
3 x 25
3 x 40

19
29
46
2 x 19
2 x 29
2 x 46
3 x 19
3 x 29
3 x 46

0.55
0.75
1.50
2 x 0.55
2 x 0.75
2 x 1.50
3 x 0.55
3 x 0.75
3 x 1.50

0.66
0.90
1.90
2 x 0.66
2 x 0.90
2 x 1.90
3 x 0.66
3 x 0.90
3 x 1.90

4
Specifications are subject to be changed without notice

RECEIVER
CAPACITY FILTRATION
L
70
70
70
70
70
70
70
70
70

FD 30 B
FD 30 B
FD 65 B
FD 60 DP
FD 60 DP
FD 60 DP
FD 60 DP
FD 60 DP
FD 130 DP

NOISE
LEVEL
dB(A)

WEIGHT

63
65
68
63
65
68
63
65
68

60
60
70
130
130
150
155
155
185

kg

Automatic vacuum plants


for medical applications
Dimensions (mm)
MINIVAC 1 PS / ARICA

MINIVAC 2 and 3 PS
700

Suction
G 1/2
650

650
Exhaust
G 1/2

739

1065

Exhaust
G 1/2

Suction
G 1/2

700

MINIVAC 3 PS MIL

MINIVAC 2 and 3 ARICA

Suction

Suct. & Exh.

1265

Exhaust

660

860

1-phase 230V
MINIVAC 1
MINIVAC 2 MIL
MINIVAC 2 C2020
MINIVAC 3 MIL
MINIVAC 3 C2020
3-phase 400V

PS 7V
919216
919218
919220
919222
919224

PS 12V
919217
919219
919221
919223
919225

16V

26V

40V

923725

923726

923727

MINIVAC 2 MIL

923716

923717

923718

MINIVAC 2 C2020

923710

923711

923712

MINIVAC 3 MIL
MINIVAC 3 C2020

923719
923713

923720
923714

923721
923715

MINIVAC 1

MINIVAC 3 C2020 ARICA

Accessory and option references


Network alarm
REPORT STATUS device

Independent
For CYCLIC 2020
For MILLENIUM
For CYCLIC 2020

708510
611027
616690
613995

MILS Oil-free Technology Plants

Plant references

5
Specifications are subject to be changed without notice

HOSPIVAC 2 & 3
Oil-free technology
Automatic and compact vacuum plants
fitting medical norms in force
Oil-free rotary vane vacuum pumps ARICA type
Shock mounts
Regulation by MILLENIUM, CYCLIC 2020 or PROCOM 2
Fit to NF EN ISO 7396-1 standard
Remote control with CYCLIC 2020 or PROCOM 2
control board
Integrated parallel duplex bacterial filtration
Delivery pot for condensate recuperation
Integrated network alarm
Included suction and exhaust hoses
Ready-to-run plants

Characteristics
NOMINAL CAPACITY
m.h-1
HOSPIVAC 2 ARICA 61V
HOSPIVAC 2 ARICA 80V
HOSPIVAC 2 ARICA 100V

50 Hz

60 Hz

50 Hz

60 Hz

2 x 60
2 x 80
2 x 100

2 x 70
2 x 90
2 x 115

2 x 1.50
2 x 2.20
2 x 3.0

2 x 1.80
2 x 2.70
2 x 3.60

NOMINAL CAPACITY
m.h-1
HOSPIVAC 3 ARICA 61V
HOSPIVAC 3 ARICA 80V
HOSPIVAC 3 ARICA 100V

POWER
kW

POWER
kW

50 Hz

60 Hz

50 Hz

60 Hz

3 x 60
3 x 80
3 x 100

3 x 70
3 x 90
3 x 115

3 x 1.50
3 x 2.20
3 x 3.0

3 x 1.80
3 x 2.70
3 x 3.60

RECEIVER
CAPACITY FILTRATION
L
650
650
650

FD 130 DP
FD 260 DP
FD 260 DP

RECEIVER
CAPACITY FILTRATION
L
650
650
650

FD 130 DP
FD 260 DP
FD 260 DP

NOISE
LEVEL
dB(A)

WEIGHT

70
72
75

320
330
340

NOISE
LEVEL
dB(A)

WEIGHT

70
72
75

390
410
435

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
MILLENIUM
 available

(PM2)
(C2020)
(MIL)




Range complying with
2007/47/CE directive

Standard power supplies


3-phase, 400V / 50Hz or 460V /
60Hz + Neutral
Other tensions on request

6
Specifications are subject to be changed without notice

1
REPORT STATUS
device

kg

kg

DUPLEX and TRIPLEX automatic vacuum plants


for medical applications
Dimensions (mm)

J
Suction

K
Exhaust

ARICA 61V
ARICA 80V
ARICA 100V

870
900
920

F1"1/4
F1"1/4
F1"1/4

M1"1/2
M1"1/2
M1"1/2

1360

2000

HOSPIVAC 2
HOSPIVAC 3

2000

1360

1100
400
J

4 holes 14

B
1100
400
4 holes 14

HOSPIVAC 2 PM2
HOSPIVAC 2 C2020
HOSPIVAC 2 MIL

ARICA 61V R65


923858
923743
923740

ARICA 80V R65


923859
923744
923741

ARICA 100V R65


923860
923745
923742

HOSPIVAC 3 PM2
HOSPIVAC 3 C2020
HOSPIVAC 3 MIL

ARICA 61V R65


923861
923749
923746

ARICA 80V R65


923862
923750
923747

ARICA 100V R65


923863
923751
923748

Optional accessory references

Transformer
Audio-warning system for MILLENIUM
Clock forced running
1

REPORT STATUS device

ARICA 61V R65


ARICA 80V R65
if no neutral current
only with CYCLIC 2020
only with CYCLIC 2020

ARICA 100V R65


611099
618295
617608
613995

MILS Oil-free Technology Plants

Plant references

7
Specifications are subject to be changed without notice

HOSPIVAC V3 SIRELLA
Oil-free technology
Contact-free compression (without maintenance)
TRIPLEX automatic vacuum plant with SIRELLA claw
vacuum pumps
Optimal saving in space at ground
Shock mounts
Electric motors PF55 type F class IE2 (special motors on request)
CYCLIC 2020 or PROCOM 2 regulation devices
FLEXO constant vacuum : regulation device to stabilize
vacuum in pipeline
Remote control with CYCLIC 2020 or PROCOM 2 control boards
Integrated parallel duplex bacterial filtration
Integrated network alarm
Included suction and exhaust hoses
Ready-to-run plants
Fit to NF EN ISO 7396-1 standard

Characteristics
NOMINAL CAPACITY
m.h-1

HOSPIVAC V3
HOSPIVAC V3 SL130
HOSPIVAC V3 SL180

POWER
kW

50 Hz

60 Hz

50 Hz

60 Hz

NOISE
LEVEL
dB(A)

3 x 112
3 x 162

3 x 132
3 x 194

3x3
3x4

3 x 3.6
3 x 4.8

76
77

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
 available

(PM2)
(C2020)

Standard power supplies


3-phase, 400V / 50Hz or 460V /
60Hz + Neutral
Other tensions on request

Range complying with


2007/47/CE directive

8
Specifications are subject to be changed without notice




WEIGHT
FILTRATION
FD 260 DP
FD 640 DP

kg
690
800

TRIPLEX automatic vacuum plants


for medical applications
Dimensions (mm)

Exhaust
F2

1700

Suction
F11/2

Receiver
F11/4

900
1500

Plant references
HOSPIVAC V3 C2020 AFDP
HOSPIVAC V3 PM2 AFDP
AFDP : with parallel duplex filtration

SL 130
922720
923334

SL 180
922721
923335

Temperature security for one pump


Temperature security for one pump
Transformer
1

REPORT STATUS device


Hose to connect receiver
Advised receiver for running
with a FLEXO constant vacuum
regulation device

with PM2
with CYCLIC 2020
if no neutral current
with CYCLIC 2020
30 x 1200 - MF 1"1/4

623841 x 3
623336 x 3
611099
613995
712927

1 x 2000 litres

722341

REPORT STATUS
device

MILS Oil-free Technology Plants

Optional accessory references

9
Specifications are subject to be changed without notice

HOSPIVAC G SIRELLA
Oil-free technology
Contact-free compression (without maintenance)
Vacuum plants for specific installations fitting medical norms
in force
Personalised units fitting any type of implantation and
accessibility
Claw vacuum pumps SIRELLA type
Shock mounts
Electric motors PF55 type - F class IE2
(special motors on request)
Available regulation modes (see the set-up layout)
FLEXO constant vacuum : regulation device
to stabilize vacuum in pipeline
Remote control with CYCLIC 2020 or PROCOM 2
control boards
Bacterial filtration
Integrated network alarm with MILLENIUM,
CYCLIC 2020 and PROCOM 2 devices
Suction and exhaust hoses delivered with each pump
Fit to NF EN ISO 7396-1 standard

Characteristics
NOMINAL CAPACITY PER PUMP
m.h-1

HOSPIVAC G
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC

G
G
G
G

SL130
SL180
SL250
SL350

POWER PER PUMP


kW

50 Hz

60 Hz

50 Hz

60 Hz

NOISE
LEVEL
dB(A)

112
162
251
342

132
194
300
412

3
4
5.5
7.5

3.6
4.8
6.6
9

76
77
78
79

240
250
460
480

from 1 to 6 pumps
2 or 3 pumps
2 or 3 pumps
1 pump






3-phase, 400V / 50Hz or 460V /


60Hz + Neutral
Other tensions and frequencies
on request

Apart bacterial filtration


 available

For more details about :


Bacterial filtrations
Vacuum receivers
Control boards

kg

Standard power supplies

Available set-up
Selected regulation
PROCOM 2 (PM2)
CYCLIC 2020 (C2020)
MILLENIUM
LG7

WEIGHT

> page 54
> page 63
> page 58

10
Specifications are subject to be changed without notice

Range complying with


2007/47/CE directive

Automatic vacuum plants


for medical applications
Dimensions (mm)
Hot air outlet

B
Suction

D
Cooling air

Exhaust

SL
SL
SL
SL

4 holes M10

130
180
250
350

A
840
850
1090
1090

A'
660
660
1040
1040

B
450
450
545
545

B'
400
400
495
495

C
665
665
750
750

D
F 1"1/2
F 1"1/2
F 2"
F 2"

E
M 1"1/2
M 1"1/2
M 2"
M 2"

Plant references
HOSPIVAC G constant vacuum regulation
TRI (3-ph) 230/400V
TRI (3-ph) 400V

SL 130
923384

SL 180
923385

SL 250

SL 350

923386

923387

723390
723394
723398
723402
723406
723410
723414
723418
723422
723426

723391
723395
723399
723403
723407
723411
723415
723419
723423
723427

2
3
2
3
PROCOM 2
4
5
6
2
MILLENIUM
3
LG7 + vacuum gauge + switch 1
CYCLIC 2020

pumps
pumps
pumps
pumps
pumps
pumps
pumps
pumps
pumps
pump

723388
723392
723396
723400
723404
723408
723412
723416
723420
723424

723389
723393
723397
723401
723405
723409
723413
723417
723421
723425

Bacterial filtration delivered separately (wall mounting) to be chosen further to flow rate installation
FD260 DP
FD 640 DP
FD 1200 DP
Parallel duplex type
814970
814971
814969

FD 2000 DP
820146

Optional accessory references


Temperature security
for one pump
Temperature security
for one pump
Transformer
REPORT STATUS device
Audio-warning system for MILLENIUM
Advised receiver for a FLEXO
constant vacuum regulation
device

2 pumps
3 pumps

Independent network connection alarm

with PM2
with C2020
If no neutral current
with C2020
1000 litres
2000 litres
2000 litres
710488
722341
722341
2000 litres
2000 litres
2000 litres
722341
722341
722341
1 vacuum switch + 1 vacuum gauge (dry contact)

623841 x X
623336 x X
611099
613995
618295
2000 litres
722341
2000 litres
722341
708510

Specifications are subject to be changed without notice

MILS Oil-free Technology Plants

Regulation device 400V+N+E

11

ANAESTIVAC 1 and 2

Anaesthetic waste gases scavenging system


ANAESTIVAC 1
Oil-free side channel vacuum pumps
Big energetic gain compared to compressed air solution
Low maintenance
Constant vacuum maintained in spite of the number
of terminal units used (patent system)
Flow adjustment on each terminal unit (patent system)
Vacuum indicator on each terminal unit (patent system)
Receiver for suction control with gauge with float level
(optional)
Flow meter with float to fit on terminal unit (optional)
Fit to NF EN ISO 7396-1 standard

ANAESTIVAC 2
version HTM

Characteristics

Y
Y
Y
Y

006
011
020
030

V
V
V
V

NOMINAL CAPACITY
per pump
L.min-1
50 Hz
60 Hz

POWER
per pump
kW
50 Hz
60 Hz

1250
2400
3500
5100

0,38
0,90
1,50
2,20

1600
3000
4166
6166

MAXI
WEIGHT
kg
with 1 pump with 2 pumps

0,42
1,15
1,75
2,64

35
45
55
70

110
120
140
160

3-ph, 400V/50Hz or 460V/60Hz + Neutral

1
Bent sleeve

4
AGSS terminal unit
wall fixation
with box

2
Silicone hose

5
AGSS terminal unit
direct wall
fixation

6
Flowmeter
with float

3
AGSS terminal unit
fixation on
head bed unit
Range complying with
2007/47/CE directive

12
Specifications are subject to be changed without notice

Anaesthetic waste gas


scavenging system
Dimensions (mm)
ANAESTIVAC 1

ANAESTIVAC 2

Exhaust
E

Exhaust
E

Suction
D

Suction
D

TYPE
Y
Y
Y
Y

006
011
020
030

V
V
V
V

A
420
420
485
485

HTM VERSION and EN VERSION


ANAESTIVAC 1
ANAESTIVAC 2
with 1 pump
with 2 pumps
B
C
A
B
750
800
800
540
720
800
800
540
780
815
970
580
850
815
970
580

CONNECTION
SUCTION
EXHAUST
D
E
1"1/4
44
1"1/2
44
2"
60
2"
60

C
1450
1450
1520
1520

TYPE
ANAESTIVAC 1
ANAESTIVAC 2

 Y 006 V
920752
920756

EN VERSION
 Y 011 V  Y 020 V
920753
920754
920757
920758

Accessory and option references


ANAESTIVAC 1 or 2
1

22 sleeve bent at 60 (NF EN ISO 9170-2)

Silicone hose 22 L = 1500 mm


AGSS terminal unit
without flow control
fixation on head bed unit
with flow control
(NF EN ISO 9170-2)
AGSS terminal unit
without flow control
wall fixation with box
with flow control
(NF EN ISO 9170-2)
AGSS terminal unit
without flow control
direct wall fixation
with flow control
(NF EN ISO 9170-2)
Flowmeter with float to fit on terminal unit

 Y 030 V
920755
920759

 Y 006 V
922219
922223

HTM* VERSION
 Y 011 V  Y 020 V
922220
922221
922224
922225

 Y 030 V
922222
922226

* This version includes an electric board with warning


lights fitting HTM guide.
 Y 006 V

 Y 011 V
Y 020 V
X x 361568

Y 030 V

X x 361630
X x 618216
X x 722199
X x 618298
X x 722200
X x 618811
X x 722201
621182
Specifications are subject to be changed without notice

MILS Oil-free Technology Plants

Plant references

13

HOSPIVAC 1

Automatic and compact vacuum plants fitting medical norms in force


Lubricated rotary vane vacuum pumps EVISA type
Shock mounts
Electric motors PF55 type F class IE2
(special motors on request)
Fit to NF EN ISO 7396-1 standard
Optional FLEXO constant vacuum : regulation device
allowing to use small capacity receivers
Simple bacterial filtration with integrated by-pass
Delivery pot for condensate recuperation
Connection for additional receiver
(in case of ON/OFF CONTROL regulation type)
Included suction and exhaust hoses
Ready-to-run plants

Characteristics
NOMINAL
CAPACITY

POWER

m3.h-1

HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC

1
1
1
1
1
1
1
1

E17
E25
E40
E65
E100
E150
E200
E300

NOISE
LEVEL

kW

50 Hz

60 Hz

50 Hz

60 Hz

17
30
47
65
96
150
190
288

20
36
56
78
115
180
228
345

0,55
0,75
1,10
1,50
2,20
3,00
4,00
5,50

0,66
0,90
1,30
1,80
2,64
3,60
4,80
6,60

RECEIVER
CAPACITY

dB(A)

OIL
FILLING
per pump
L

59
60
62
65
67
70
71
73

1,5
1,5
1,5
4,0
4,0
7,0
7,0
7,0

300
300
300
300
300
500
500
500

FILTRATION

kg

FD 30 B
FD 30 B
FD 65 B
FD 65 B
FD 130 B
FD 320 B
FD 320 B
FD 320 B

Available set-up
Selected regulation
LG7
 available

1 pump

Range complying with


2007/47/CE directive

Standard power supplies


3-phase, 400V/50Hz or
460V/60Hz + Neutral
Other tensions on request

14
Specifications are subject to be changed without notice

1
Vertical vacuum
receiver

2
Network
connection alarm

WEIGHT

150
150
160
190
200
230
245
330

Automatic vacuum plants


for medical applications
Dimensions (mm)
A

 K

HOSPIVAC 1
E17
E25
E40
E65
E100
E150
E200
E300

A
1650
1650
1650
1645
1645
2045
2045
2045

B
840
840
840
850
850
990
990
990

C
1040
1040
1040
1135
1135
1315
1315
1370

D
300
300
300
300
300
360
360
360

E
995
995
995
995
995
1200
1200
1200

F
265
265
265
275
275
270
270
270

G
325
325
325
325
325
345
345
345

4 x 14

J network K exhaust
1
1
1
1
1
1
11/4
11/2
11/4
11/2
2
2
2
2
2
2

Plant references
ON/OFF control regulation
HOSPIVAC 1 Exx - AFS*

E17 R3 E25 R3 E40 R3 E65 R3 E100 R3 E150 R5 E200 R5 E300 R5


916681 916568 916569 916570 916571 916572 916573 916574

FLEXO constant vacuum regulation device E17 R3 E25 R3 E40 R3 E65 R3 E100 R3 E150 R5 E200 R5 E300 R5
HOSPIVAC 1 Exx - AFS*
919107 919108 919109 919110 919111 919112 919113 919114
* : AFS simple filtration with by-pass

Accessory and option references


Oil level security for one pump
Oil level and temperature securities
1

Additional vertical receiver


for ON/OFF control regulation
Network connection alarm

E17 R3 E25 R3 E40 R3 E65 R3 E100 R3 E150 R5 E200 R5 E300 R5


610396
623327
623991
619195
623328

623329

623992

623330

500 litres

1000 litres

2000 litres

2 x 2000 litres

710486

710488

722341

2 x 722341

1 vacuum gauge and 1 pressure gauge (dry contact)

MILS Lubricated Technology plants

708510

Specifications are subject to be changed without notice

15

HOSPIVAC 2
Automatic and compact vacuum plants
fitting medical norms in force
Lubricated rotary vane vacuum pumps EVISA type
Shock mounts
Electric motors PF55 type F class IE2
(special motors on request)
Available regulation modes
(see the set-up layout)
Fit to NF EN ISO 7396-1 standard
Option FLEXO constant vacuum : regulation device
allowing to use small capacity receivers
Remote control with CYCLIC 2020 or PROCOM 2
control boards
Integrated parallel duplex bacterial filtration
Delivery pot for condensate recuperation
Integrated network alarm
Included suction and exhaust hoses
Ready-to-run plants

Characteristics
NOMINAL CAPACITY
m.h-1
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC

2
2
2
2
2
2
2
2

E17
E25
E40
E65
E100
E150
E200
E300

50 Hz

60 Hz

2 x 17
2 x 30
2 x 47
2 x 65
2 x 96
2 x 150
2 x 190
2 x 288

2 x 20
2 x 36
2 x 56
2 x 78
2 x 115
2 x 180
2 x 228
2 x 345

POWER
kW
50 Hz
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

0.55
0.75
1.10
1.50
2.20
3.00
4.00
5.50

RECEIVER
CAPACITY FILTRATION
L

60 Hz
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

0.66
0.90
1.30
1.80
2.64
3.60
4.80
6.60

500
500
500
650
650
750
750
750

FD 60 DP
FD 60 DP
FD 130 DP
FD 130 DP
FD 260 DP
FD 640 DP
FD 640 DP
FD 640 DP

NOISE
LEVEL
dB(A)
59
60
62
65
67
70
71
73

OIL
FILLING
L
2
2
2
2
2
2
2
2

x
x
x
x
x
x
x
x

1.5
1.5
1.5
4.0
4.0
7.0
7.0
7.0

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
MILLENIUM
 available

(PM2)
(C2020)
(MIL)

Standard power supplies


3-phase, 400V / 50Hz or 460V /
60Hz + Neutral
Other tensions on request
16
Specifications are subject to be changed without notice





Range complying with


2007/47/CE directive

1
REPORT STATUS
device

WEIGHT
kg
200
205
225
335
355
460
490
660

DUPLEX automatic vacuum plants


for medical applications
Dimensions (mm)
HOSPIVAC 2 E17 to E200

HOSPIVAC 2 E300

2305
2
1545

K
C

J
2

990
B

1500

400

400
4 holes 14

4 holes 14

HOSPIVAC 2

J
network

K
exhaust

E17/E25
E40
E65/E100
E150/E200

1650
1650
2000
2305

850
850
900
1045

1300
1300
1380
1425

1100
1100
1100
1500

F 1"
F 1"
F 1"1/4
F 2"

M 1"
M 1"
M 1"1/2
M 2"

"ON/OFF control" regulation (TOR)


HOSPIVAC 2 PM2 Exx
HOSPIVAC 2 C2020 Exx
HOSPIVAC 2 MIL Exx

E17 R50 E25 R50 E40 R50 E65 R65 E100 R65E150 R75E200 R75E300 R75
923611
923612
923613
923614
923768
923769
923785
923610
923615
923616
923617
923618
923619
923770
923771
923786
923621
923622
923623
923624
923772
923773
923787
923620

FLEXO constant vacuum regulation device E17 R50 E25 R50 E40 R50 E65 R65 E100 R65E150 R75E200 R75E300 R75
923626
923627
923628
923629
923774
923775
923788
HOSPIVAC 2 PM2 Exx
923625
HOSPIVAC 2 C2020 Exx
923630
923631
923632
923633
923634
923776
923777
923789
923636
923637
923638
923639
923778
923779
923790
HOSPIVAC 2 MIL Exx
923635

Accessory and option references


E17 R50 E25 R50 E40 R50 E65 R65 E100 R65E150 R75E200 R75E300 R75
616111 x 2
622886 x 2
616112 x 2
623337 x 2
623975 x 2
623976 x 2
623977 x 2
623978 x 2
616564 x 2
623320 x 2
623992 x 2
619196 x 2
623321 x 2
623324 x 2
623994 x 2
623325 x 2
with CYCLIC 2020
weekly clock
613996
with CYCLIC 2020
617608
1 REPORT STATUS device
with CYCLIC 2020
613995
Audio-warning system for MILLENIUM
618295
Transformer
if no neutral current
611099

Oil level security  PM2


Oil level + tC securities  PM2
Oil level security  C2020
Oil level + tC securities  C2020
FLEXO or ON/OFF external control
Clock forced running

Specifications are subject to be changed without notice

MILS Lubricated Technology plants

Plant references

17

HOSPIVAC 3
Automatic and compact vacuum plants
fitting medical norms in force
Lubricated rotary vane vacuum pumps EVISA type
Shock mounts
Electric motors PF55 type F class IE2
(special motors on request)
Available regulation modes
(see the set-up layout)
Fit to NF EN ISO 7396-1 standard
Option FLEXO constant vacuum : regulation device
allowing to use small capacity receivers
Remote control with CYCLIC 2020 or PROCOM 2
control boards
Integrated parallel duplex bacterial filtration
Delivery pot for condensate recuperation
Integrated network alarm
Included suction and exhaust hoses
Ready-to-run plants

Characteristics
NOMINAL CAPACITY
m.h-1
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC

3
3
3
3
3
3
3

E17
E25
E40
E65
E100
E150
E200

50 Hz

60 Hz

3 x 17
3 x 30
3 x 47
3 x 65
3 x 96
3 x 150
3 x 190

3 x 20
3 x 36
3 x 56
3 x 78
3 x 115
3 x 180
3 x 228

POWER
kW
50 Hz
3
3
3
3
3
3
3

x
x
x
x
x
x
x

0.55
0.75
1.10
1.50
2.20
3.00
4.00

RECEIVER
CAPACITY FILTRATION
L

60 Hz
3
3
3
3
3
3
3

x
x
x
x
x
x
x

0.66
0.90
1.30
1.80
2.64
3.60
4.80

500
500
500
650
650
750
750

FD 60 DP
FD 60 DP
FD 130 DP
FD 130 DP
FD 260 DP
FD 640 DP
FD 640 DP

NOISE
LEVEL
dB(A)
59
60
62
65
67
70
71

OIL
FILLING
L
3
3
3
3
3
3
3

x
x
x
x
x
x
x

1.5
1.5
1.5
4.0
4.0
7.0
7.0

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
MILLENIUM
 available

(PM2)
(C2020)
(MIL)

Standard power supplies


3-phase, 400V / 50Hz or 460V /
60Hz + Neutral
Other tensions on request
18
Specifications are subject to be changed without notice





Range complying with


2007/47/CE directive

1
REPORT STATUS
device

WEIGHT
kg
280
290
320
405
435
615
655

TRIPLEX automatic vacuum plants


for medical applications
Dimensions (mm)

HOSPIVAC 3

J
network

K
exhaust

E17/E25
E40
E65/E100
E150/E200

1650
1650
2000
2305

850
850
900
1045

1300
1300
1380
1425

1100
1100
1100
1500

F 1"
F 1"
F 1"1/4
F 2"

M 1"
M 1"
M 1"1/2
M 2"

B
D
400
4 holes 14

E17 R50
923580
923585
923590

E25 R50
923581
923586
923591

E40 R50
923582
923587
923592

E65 R65
923583
923588
923593

E100 R65 E150 R75 E200 R75


923584
923756
923757
923589
923758
923759
923594
923760
923761

FLEXO constant vacuum regulation device E17 R50


HOSPIVAC 3 PM2 Exx
923595
HOSPIVAC 3 C2020 Exx
923600
HOSPIVAC 3 MIL Exx
923605

E25 R50
923596
923601
923606

E40 R50
923597
923602
923607

E65 R65
923598
923603
923608

E100 R65 E150 R75 E200 R75


923599
923762
923763
923604
923764
923765
923609
923766
923767

"ON/OFF control" regulation (TOR)


HOSPIVAC 3 PM2 Exx
HOSPIVAC 3 C2020 Exx
HOSPIVAC 3 MIL Exx

Accessory and option references


Oil level security  PM2
Oil level + tC securities  PM2
Oil level security  C2020
Oil level + tC securities  C2020
FLEXO or ON/OFF external control
Clock forced running

E17 R50

E25 R50 E40 R50


616111 x 3
623975 x 3
616564 x 3
623321 x 3
with CYCLIC 2020
with CYCLIC 2020
with CYCLIC 2020

1 REPORT STATUS device


Audio-warning system for MILLENIUM
Transformer
if no neutral current

E65 R65 E100 R65 E150 R75 E200 R75


622886 x 3
616112 x 3
623976 x 3
623977 x 3
623320 x 3
623992 x 3
623324 x 3
623994 x 3
weekly clock
613996
617608
613995
618295
611099
Specifications are subject to be changed without notice

MILS Lubricated Technology plants

Plant references

19

HOSPIVAC V3

Vacuum plants for specific installations fitting medical norms in force


Optimal saving in space at ground
Lubricated rotary vane vacuum pumps EVISA type
Shock mounts
Electric motors PF55 type F class IE2(special motors on request)
Several available regulation modes (see the set-up layout)
Option FLEXO constant vacuum : regulation device
allowing to use small capacity receivers
Remote control with CYCLIC 2020 or PROCOM 2 control boards
Integrated parallel duplex bacterial filtration
Delivery pot for condensate recuperation
Fit to NF EN ISO 7396-1 standard
Integrated network alarm
Included suction and exhaust hoses
Ready-to-run plants

Characteristics
NOMINAL
CAPACITY
m3.h-1
50 Hz

3 x 17
HOSPIVAC V3 E17
3 x 30
HOSPIVAC V3 E25
3 x 47
HOSPIVAC V3 E40
3 x 65
HOSPIVAC V3 E65
3 x 96
HOSPIVAC V3 E100
3 x 150
HOSPIVAC V3 E150
3 x 190
HOSPIVAC V3 E200
3 x 288
HOSPIVAC V3 E300
Simple version on request consult us

POWER
kW
60 Hz

50 Hz

3 x 20
3 x 36
3 x 56
3 x 78
3 x 115
3 x 180
3 x 228
3 x 345

3
3
3
3
3
3
3
3

x
x
x
x
x
x
x
x

0,55
0,75
1,10
1,50
2,20
3,00
4,00
5,50

60 Hz

3
3
3
3
3
3
3
3

x
x
x
x
x
x
x
x

0,66
0,90
1,30
1,80
2,64
3,60
4,80
6,60

NOISE
LEVEL
dB(A)

OIL
FILLING
L

FILTRATION

59
60
62
65
67
70
71
73

1,5
1,5
1,5
4,0
4,0
7,0
7,0
7,0

FD 60 DP
FD 60 DP
FD 130 DP
FD 130 DP
FD 260 DP
FD 640 DP
FD 640 DP
FD 1200 DP

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
MILLENIUM
 available





Standard power supplies


3-phase, 400V/50Hz or
460V/60Hz + Neutral
Other tensions on request
Range complying with
2007/47/CE directive

20
Specifications are subject to be changed without notice

WEIGHT
kg

180
185
215
460
470
670
800
940

HOSPIVAC V4/V5/V6
Vacuum plants for specific installations fitting
medical norms in force
Optimal saving in space at ground
Lubricated rotary vane vacuum pumps EVISA type
Pump mounted on sliding drawers
Electric motors PF55 type F class IE2
(special motors on request)
PROCOM 2 regulation device
FLEXO constant vacuum : regulation device
allowing to use small capacity receivers
Remote control through RS485/Modbus or Ethernet
connection
Integrated parallel duplex bacterial filtration
Delivery pot for condensate recuperation
Fit to NF EN ISO 7396-1 standard
Integrated network alarm
Included suction and exhaust hoses
Ready-to-run plants

Characteristics
HOSPIVAC V4
HOSPIVAC V5
HOSPIVAC V6
HOSPIVAC VX E100 PM2
HOSPIVAC VX E200 PM2
HOSPIVAC VX E300 PM2

NOMINAL
CAPACITY
m.h-1
50 Hz
60 Hz
X x 96
X x 115
X x 190
X x 228
X x 288
X x 385

POWER
kW
50 Hz
X x 2,20
X x 4,00
X x 5,50

60 Hz
X x 2.64
X x 4,80
X x 6.60

NOISE
LEVEL
dB(A)

OIL
FILLING
L

67
71
73

X x 4,0
X x 7,0
X x 7,0

FILTRATION
for
HOSPIVAC V4
2 x FD320S
2 x FD600S
3 x FD600S

HOSPIVAC V5
2 x FD600S
3 x FD600S
3 x FD600S

HOSPIVAC V6
2 x FD600S
3 x FD600S
4 x FD600S

Standard power supplies


3-phase, 400V/50Hz or
460V/60Hz + Neutral
Other tensions on request
Range complying with
2007/47/CE directive

Suction hoses

22
Specifications are subject to be changed without notice

Vertical vacuum
receiver

HOSPIVAC G
Vacuum plants for specific installations fitting medical norms in force
Personalised units fitting any type of implantation and accessibility
Lubricated rotary vane vacuum pumps EVISA type
Shock mounts
Electric motors PF55 type F class IE2 (special motors on request)
Available regulation modes (see the set-up layout)
Option FLEXO constant vacuum : regulation device allowing
to use small capacity receivers
Remote control with CYCLIC 2020 or with PROCOM 2 control boards
Bacterial filtration
Delivery pot for condensate recuperation
Fit to NF EN ISO 7396-1 standard
Integrated network alarm with MILLENIUM, CYCLIC 2020
and PROCOM 2 devices
Suction and exhaust hoses delivered with each pump

Characteristics

HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC

NOMINAL
CAPACITY
per pump
m3.h-1
50 Hz
60 Hz

G
G
G
G
G
G
G
G
G
G
G
G

E17
E25
E40
E65
E100
E150
E200
E300
E350
E400
E500
E600

17
30
47
65
96
150
190
288
360
426
513
632

20
36
56
78
115
180
228
345
432
511
616
758

from 1 to 6 pumps
2 or 3 pumps
2 or 3 pumps
1 pump

Bacterial filtration
Apart bacterial filtration
 available

Range complying with


2007/47/CE directive
24
Specifications are subject to be changed without notice

per pump
kW
50 Hz
60 Hz

0,55
0,75
1,10
1,50
2,20
3,00
4,00
5,50
7,50
9,00
11,00
15,00

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
MILLENIUM
LG7

POWER







0,66
0,90
1,30
1,80
2,64
3,60
4,80
6,60
9,00
10,80
13,20
18,00

NOISE
LEVEL
per pump
dB(A)

OIL
FILLING
L

RECEIVER
IF REGULATION
L
ON/OFF CONTROL

59
60
62
65
67
70
71
73
74
74
74
75

1,5
1,5
1,5
4,0
4,0
7,0
7,0
7,0
10,0
10,0
10,0
10,0

FLEXO

Flow rate in
Flow rate in
L.min-1 of all L.min-1 of all
the set up
the set up
pumps divided
pumps gives
by 4, gives
you receiver
you receiver
capacity to be capacity to be
foreseen
foreseen

Scalable automatic vacuum plants


for medical applications
Dimensions (mm)
Control boards
For 1 to 6 motors

For 1 to 3 motors

500

300

700

600

30

270

LG7 device

REPORT STATUS device


70

115

210

195

230

MILS Lubricated Technology plants

125

EVISA MV vacuum pumps shock mounts, see page 48


Bacterial filtrations, see page 54
Vacuum receivers, see page 63

Standard power supplies


3-phase, 400V/50Hz or
460V/60Hz + Neutral
Other tensions on request

25
Specifications are subject to be changed without notice

HOSPIVAC G

1
Bacterial filtration

Plant references
HOSPIVAC G C2020, G MIL and G PM2
ON/OFF CONTROL regulation type

2
REPORT STATUS
device

3-ph 400V
1-ph 230V

FLEXO constant vacuum regulation device


3-ph 400V
1-ph 230V

3
Lowest level
drip pot
ON/OFF CONTROL
regulation
or
FLEXO CONSTANT VACUUM
400V+N+E

CYCLIC 2020

2 pumps
3 pumps

PROCOM 2

2 pumps
3 pumps
4 pumps
5 pumps

4
Vertical vacuum
receiver

5
Network
connection alarm

6 pumps
2 pumps
ON/OFF CONTROL regulation
MILLENIUM
3 pumps
400V+N+E
2 pumps
FLEXO regulation
MILLENIUM
3 pumps
CONSTANT VACUUM
ON/OFF regulation (400V+N+E)
LG7 + vacuum gauge + vacuum switch
ON/OFF regulation (1-ph 230V)
LG7 + vacuum gauge + vacuum switch
Constant vacuum regulation (400V+N+E) LG7 + vacuum gauge + vacuum switch
Constant vacuum regulation (1-ph 230V) LG7 + vacuum gauge + vacuum switch

Wall-mounted
bacterial filtration
delivered separately
(wall mounting)

Single with by-pass

Without by-pass with isolating valve

Parallel DUPLEX

Accessory and option references


Oil level security with PM2
Oil level + temperature securities with PM2
Oil level security with C2020/MIL
Oil level + temperature securities with C2020/MIL
Transformer 400V/230V assembly
2

REPORT STATUS device


FLEXO or ON/OFF external control
Clock forced running
Audio-warning system for MILLENIUM

Lowest level drip pot


Bacterial cartridge at exhaust
Elevated assembly on retention vat

for 1 pump
for 1 pump
for 1 pump
for 1 pump
if no neutral current

1 pump
2 pumps
3 pumps

26
Specifications are subject to be changed without notice

2 pumps
Advised receiver for a FLEXO
3 pumps
constant vacuum regulation device
Vertical receiver for ON/OFF CONTROL regulation

Independent network connection alarm

Automatic vacuum plants


for medical applications
E17
916699

E25
911818
916087

E40
911819
916088

E65
914472

E100
914473

E150
914474

E200
914475

E300
916672

E17
919181

E25
919182
919193

E40
919183
919194

E65
919184

E100
919185

E150
919186

E200
919187

E300
919188

E25
E40
E65
723820
723554
723702
723823
723725
723788
716541
716546 716551
716542
716547 716552
716543
716548 716553
723827
723792
723793
723816
723811
723812
717743
717744
718296 718297
719337
719338
719342 719343

E100
723821
723555
723824
723789
716556
716557
716558
723828
723794
723817
723813
717745

E150
E200
E300
723822
723800
723573
723556
723825
723791
723790
723826
716561 716561 716589
716562 716585 716590
716563 716586 716591
723829
723830
723795
723796
723818
723819
723814
723815
717746
717747

719339

719340

E17

E350
917639

E400
918284

E500
917640

E600
918285

E350
717645
717647
717641
717642

E400
718290
718291
718286
718287

E500
717646
717648
717643
717644

E600
718292
718293
718288
718289

719341

Filtration to be chosen further to flow rate installation


FD 30 B

FD 65 B

FD 130 B

FD 320 B

FD 600 B

FD 1000 B

811848

811849

811850

811851

811852

814915

2 x FD 1000 S

FD 60 DP

FD 130 DP

FD 260 DP

FD 640 DP

FD 1200 DP

FD 2000 DP

814967

814968

814969

814970

814971

820146

E17

E25
616111 x
623975 x
616564 x
623321 x

E40
X
X
X
X

E65
E100
622886 x X
623976 x X
623320 x X
623324 x X

E150
E200
616112 x X
623977 x X
623992 x X
623994 x X
611099

only with CYCLIC 2020

711103
617610
619543
619546
500 litres :

weekly clock
possible if FLEXO control

618295
PR 30 : 712068
717263
617611
619544
617614
710486

500 litres : 710486

1000 litres :

E350

E400
623314
623979
623332
623326

E500
xX
xX
xX
xX

E600

613995
613996
617608

only with CYCLIC 2020


only with CYCLIC 2020

E300
623337xX
623978xX
619196xX
623325xX

PR 60 : 706547
617612
619545
710488

1000 litres : 710488

617613

2000 litres :

2000 litres : 722341

MILS Lubricated Technology plants

2 x 817753

722341
2x2000 litres : 2x722341 3x2000 litres : 3x722341

contact us
1 vacuostat and 1vacuum gauge (dry contact)

708510
Specifications are subject to be changed without notice

27

HOSPIVAC C
Specified vacuum pumps for outdoors implantation
3 lubricated rotary vane vacuum pumps EVISA type
Available regulation modes (see the set-up layout)
Option FLEXO constant vacuum : regulation device allowing
to use small capacity receivers
Duplex parallel bacterial filtration integrated
in the cabin
Delivery pot for condensate recuperation
Fit to NF EN ISO 7396-1 standard
Integrated network alarm
Integrated oil level and temperature securities
Integrated receiver(s) in the cabin
Ready-to-run plants

Characteristics
NOMINAL
CAPACITY
per pump
m3.h-1
50 Hz
60 Hz

3 pumps

HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC
HOSPIVAC

C3
C3
C3
C3
C3
C3
C3

E25
E40
E65
E100
E150
E200
E300

3 x 30
3 x 47
3 x 65
3 x 96
3 x 150
3 x 190
3 x 288

3 x 36
3 x 56
3 x 78
3 x 115
3 x 180
3 x 228
3 x 345

POWER

FILTRATION

per pump
kW
50 Hz
60 Hz

3
3
3
3
3
3
3

x
x
x
x
x
x
x

0,75
1,10
1,50
2,20
3,00
4,00
5,50

3
3
3
3
3
3
3

x
x
x
x
x
x
x

0,90
1,30
1,80
2,64
3,60
4,80
6,60

OIL
FILLING

TOTAL
POWER

FD 60 DP
FD 130 DP
FD 130 DP
FD 260 DP
FD 640 DP
FD 640 DP
FD 1200 DP

1,5
1,5
4,0
4,0
7,0
7,0
7,0

INSTALLED
RECEIVER(S)
CAPACITY
L

kW
50 Hz

60 Hz

6,5
7,5
8,8
10,8
13,3
16,3
20,7

7,8
9,0
10,6
13,0
16,0
19,6
24,8

500
500
800
800
2 x 1000
2 x 1000
2 x 1000

Available set-up
Selected regulation
PROCOM 2
CYCLIC 2020
 available

3 pumps
3 pumps

Standard power supplies


3-phase, 400V/50Hz or
460V/60Hz + Neutral
Other tensions on request

28
Specifications are subject to be changed without notice




Range complying with


2007/47/CE directive

CABIN automatic vacuum plants


for medical applications
Dimensions (mm)
HOSPIVAC Cabine E25 to E40

2700

aus

Exh

Suctio

00

24

2000
900

2700

HOSPIVAC Cabine E65 to E300

ion

Exhaust

ct
Su

00

3000 for HO
SPIVAC CABI
900
NE 3 X E65
or 3 X E100
4000 for HO
SPIVAC CABI
NE
3 X E150 or
3 X E200 or
3 X E300

Plant references
FLEXO constant vacuum regulation device
HOSPIVAC C3 PM2 Exx-AFDP*

PROCOM 2

HOSPIVAC C3 C2020 Exx-AFDP*CYCLIC 2020


* : AFDP - parallel duplex filtration

HOSPIVAC C3 E25
HOSPIVAC C3 E40
HOSPIVAC C3 E65
HOSPIVAC C3 E100
HOSPIVAC C3 E150
HOSPIVAC C3 E200
HOSPIVAC C3 E300

E25

E40

E65

E100

E150

E200

E300

919209

919210

919211

919212

919213

919214

919215

918588

918589

918590

918591

918592

918593

918594

Weight
kg

1
1
1 1/2
1 1/2
2
2
2

1100
1140
1530
1560
2076
2115
2340

MILS Lubricated Technology plants

24

29
Specifications are subject to be changed without notice

LABOVAC 1

Automatic and compact vacuum plants for laboratories


Liquid ring vacuum pump ANTIGUA type
Partial water recycling system
Capable of handling draw-in dust
Water flow regulation
Easy setting
Electromechanical control board (2 thresholds vacuum switch)
Simple bacterial filtration with optional by-pass

Characteristics
RECEIVER
CAPACITY
kW
L
0.75
300
1.5
300
3
300
4
500
5.5
500
7.5
500
less than 200 mbar abs.

NOMINAL
CAPACITY
m3.h-1

50 Hz
27
LABOVAC 1 S26
49
LABOVAC 1 S51
89
LABOVAC 1 S126
152
LABOVAC 1 S161
230
LABOVAC 1 S251
290
LABOVAC 1 S325
* consumption for a low pressure

POWER

NOISE
LEVEL
dB(A)
68
68
67
65
65
70

WATER CONSU.* (L/min)


opened range

with separator

4
4
8
16
16
20

2
2
4
8
8
12

Available set-up





Assembly with separator for partial water recycling


Assembly without separator
Bacterial filtration
Network alarm
 standard equipment
 optional equipment

Standard power supplies


3-phase, 400V/50Hz
Other tensions on request

Water flow
regulation

1
Bacterial filtration

Air/water
separator trap

30
Specifications are subject to be changed without notice

Water supply

2
Network
connection alarm

3
Vertical vacuum
receiver

4
Suction hoses

WEIGHT
kg
135
140
160
260
280
330

Liquid ring vacuum plants


Dimensions (mm)
l

H1

A
H
e
EV

HEIGHT

LABOVAC 1 S26

LABOVAC 1 S51

LABOVAC 1 S126

LABOVAC 1 S161

LABOVAC 1 S251

EV

800

1"1/2

1"

3/8"

3/4"

3/4"

650

800

1"1/2

1"

3/8"

3/4"

3/4"

650

800

1"1/2

1"1/4

3/8"

1"1/4

1"1/4

750

1100

1"1/2

1"1/2

3/8"

1"1/2

2"

980

1100

1"1/2

1"1/2

3/8"

1"1/2

2"

980

1100

1"1/2

1"1/2

3/8"

1"1/2

2"

H1

1700

1050

1450

650

1700

1050

1450

1700

1250

1550

1950

1400

1750

1950

1500

1850
2000

1950
1500
LABOVAC 1 S325
H : Height without partial recovery device
H1 : Height with partial recovery device

without filtration with filtration

Plant references
LABOVAC 1 - 50 Hz with separator
LABOVAC 1 - 50 Hz without separator

S26 R3
920771
920022

S51 R3
920772
920023

S126 R3
920773
920024

S161 R5
920774
920025

S251 R5
920775
920026

S325 R5
920776
920027

S26 R3

S51 R3

S126 R3

S161 R5

S251 R5

S325 R5

FD30B
811833

FD65B
811834

FD130B
811835

Accessory and option references


1

Simple bacterial filtration with by-pass


mounted on receiver

Network alarm
Optional transformer 400V/230V fitting

Additional receiver with vacuum gauge


and draining valve

500 litres
710486

or

Connection hose for additional receiver

710992

710993

FD320B
811836

1 vacuum switch + 1 vacuum gauge (dry contact)


611099
1000 litres
710488

Liquid ring Technology plants

TYPE

WIDTH
(l)

MILS

LENGTH

708510

or

2000 litres
722341

710994
31
Specifications are subject to be changed without notice

LABOVAC 2

Automatic and compact vacuum plants for laboratories


Liquid ring vacuum pumps ANTIGUA type
Partial water recycling system
Capable of handling draw-in dust
Water flow regulation
Easy setting
MILLENIUM PLC control board or electronic cards CYCLIC 2020
Simple bacterial filtration with by-pass mounted on plant
or delivered separately

Characteristics

50 Hz
LABOVAC 2 S26
LABOVAC 2 S51
LABOVAC 2 S126
LABOVAC 2 S161
LABOVAC 2 S251
LABOVAC 2 S325
* consumption for a

NOMINAL
POWER
CAPACITY
kW
m3.h-1
2 x 27
2 x 0.75
2 x 49
2 x 1.5
2x3
2 x 89
2 x 152
2x4
2 x 5.5
2 x 230
2 x 290
2 x 7.5
pressure less than 200 mbar abs.

RECEIVER
CAPACITY
L
500
500
500
800
800
800

NOISE
LEVEL
dB(A)
68
68
67
65
65
70

Available set-up

WATER CONSU.* (L/min)


opened range

with separator

2x4
2x4
2x8
2 x 16
2 x 16
2 x 20

2x2
2x2
2x4
2x8
2x8
2 x 12









3-phase, 400V/50Hz
Other tensions on request

Air/water
separator trap

Water flow
regulation

3
Vertical vacuum
receiver

Water supply

2
Bacterial filtration

4
Suction hoses

Specifications are subject to be changed without notice

kg
210
220
260
430
470
570

Standard power supplies

Assembly with separator for partial water recycling


Assembly without separator
CYCLIC 2020
MILLENIUM
Bacterial filtration mounted on receiver
Wall fixation bacterial filtration
Network alarm
 Standard equipment  Optional equipment

32

WEIGHT

DUPLEX liquid ring vacuum plants


Dimensions (mm)
L

H1

A
H
e

EV

HEIGHT

LABOVAC 2 S126

LABOVAC 2 S161

LABOVAC 2 S251

EV

1100

1"1/2

1"1/4

1/2"

1"1/4

3/4"

1000

1100

1"1/2

1"1/4

1/2"

1"1/4

1"1/4

1000

1200

1"1/2

1"1/2

1/2"

1"1/2

2"

1050

1250

2"

2"

1/2"

1"1/2

2"

1050

1250

2"

2"

1/2"

1"1/2

2"

2"

2"

1/2"

1"1/2

2"

H1

1950

1200

1450

1000

1950

1200

1450

1950

1400

1750

2350

1500

1900

2350

1600

1950

without filtration with filtration

2350
1600
2100
1050
1250
LABOVAC 2 S325
H : Height without partial recovery device
H1 : Height with partial recovery device

Plant references
LABOVAC 2 C2020 With separator
50Hz
Without separator
With separator
LABOVAC 2 MIL
50Hz
Without separator

S26 R5
920783
920034
920795
920046

S51 R5
920784
920035
920796
920047

S126 R5
920785
920036
920797
920048

S161 R8
920786
920037
920798
920049

S251 R8
920787
920038
920799
920050

S325 R8
920788
920039
920800
920051

S126 R5

S161 R8

S251 R8

S325 R8

Accessory and option references


2

S26 R5

S51 R5

Simple bacterial filtration with by-pass


mounted on receiver

FD65B
812306

FD130B
812308

FD320B
811836

FD600B
811837

Wall fixation bacterial filtration with


by-pass delivered separately

811849

811850

811851

811852

version CYCLIC 2020


version MILLENIUM
611099

Network alarm with sensor


Optional transformer 400V/230V fitting
3

Additional receiver with vacuum gauge


and draining valve

500 litres
710486

or

Connection hose for additional receiver

710992

710993

1000 litres
710488

611027
616690

or

Liquid ring Technology plants

LABOVAC 2 S51

TYPE
LABOVAC 2 S26

WIDTH
(l)

MILS

LENGTH

2000 litres
722341

710994
33
Specifications are subject to be changed without notice

MAVO Emergency station


Ultimate back-up system designed to guarantee the medical
fluid supply of certain hospital services (surgical units,
reanimation type,) in the event of dysfunction of the main
feeder system in order to finish the operations in progress.
Standard version :
- Medical vacuum with an oil-free rotary vane vacuum pump ARICA 40 or
a lubricated vacuum pump EVISA E40 MV type (consult us),
- Medical oxygen with 2 mobile oxygen cylinders,
- Medical air with 2 mobile air cylinders.
On request :
- Nitrous oxide
- Medical air - 7 bar
The most compact of the market for an easy integration
Two cylinders per gas ensure the continuity of supply
Restoring of initial pressure
The emergency station is activated by pressure difference without
electrical supply (except vacuum network)
Electronic signals of medical gas networks by VISIO unit integrated
to the emergency station
Alarm remote unit in operating theatres (accessory)
Simplified and quick connection to any type of network
Ready-to-run emergency station (cylinders not provided)

Technical data of MAVO emergency station


Power supply
1-phase 230V - 50 Hz

Total power
1200 W

Weight
195 kg

AIR

OXYGEN

ARICA 40V 1-ph 230V


Capacity : 40 m/h
Motor power : 1.5 kW

1 x B50 (10 m)
+ 1 x B20 (4 m)

1 x B50 (10 m)
+ 1 x B20 (4 m)

ARICA 40V 1-ph 230V


Capacity : 40 m/h
Motor power : 1.5 kW

2 x B50 (20 m)

2 x B50 (20 m)

ARICA 40V 1-ph 230V


Capacity : 40 m/h
Motor power : 1.5 kW

1 x B50 (10 m)
+ 1 x B15 (3 m)
+ 2 x B15 (6 m)

1 x B50 (10 m)
+ 1 x B15 (3 m)
+ 2 x B15 (6 m)

Available set-up
VACUUM

34
Specifications are subject to be changed without notice

Range complying with


2007/47/CE directive

Medical gas supply system

Dimensions (mm)
MAVO
Simple ARICA 40V
4B50 ARICA 40V
Double ARICA 40V

L
1150
1350
1350

L1
600
675
675

L2
550
675
675

H
1800
1800
2000

P
420
420
500
100
580

Vacuum (3/4)
Air (1/2)
O2 (1/2)

Emergency and back-up systems

800 adjustable

pipe cover

L2

L1

Reference
MAVO simple : Vacuum ARICA 40V

AIR B50+B20

O2 B50+B20

923803

MAVO 4B50 :

AIR B50+B50

O2 B50+B50

923735

AIR B50+1xB15
+2xB15

O2 B50+1xB15

923801

MAVO double : Vacuum ARICA 40V

+2xB15

MILS

Vacuum ARICA 40V

Accessory and option references


Pipe cover (except for MAVO double)
VISIO REPORT
O2 or Air network valve 1/2"
Vacuum network valve

projecting
3/4"

219823
623715
623930
654227

fitted

623716

1"

654903
35

Specifications are subject to be changed without notice

Automatic vacuum plants


for medical applications

MOBILE MINIVAC
Mobile and independent vacuum plant
Lubricated rotary vane vacuum pumps (EVISA MV)
Regulation by mechanical vacuum switch
Receiver : 70 L
Suction bacterial filtration
Exhaust bacterial cartridge
Standard suction network inlet (one on series,
one on option)
Ready-to-run plants

Range complying with


2007/47/CE

Characteristics
For more details about EVISA pumps, please report page 48
MOBILE MINIVAC
Lubricated rotary vane
vacuum pumps
TYPE

Mobile MINIVAC E17


Mobile MINIVAC E25
Mobile MINIVAC E40

NOMINAL
CAPACITY
m3.h-1
50 Hz
60 Hz

17
30
47

POWER
kW

20
36
56

50 Hz

60 Hz

0,55
0,75
1,10

0,66
0,90
1,30

RECEIVER
CAPACITY
L

FILTRATION

70
70
70

FD 30 B
FD 30 B
FD 65 B

NOISE
LEVEL
dB(A)

OIL
FILLING
L

WEIGHT

59
60
62

1,5
1,5
1,5

85
85
100

kg

Plant references
1-ph 230V
MOBILE MINIVAC 1 Exx - AFS* 3-ph 400V
* : AFS simple filtration with by-pass

E17

E25

E40

916711

912320
912943

912209
912945

MOBILE MINIVAC 1 Exx - AFS*

Accessory and option references


independent

708510
610396
620449

Suction
G1/2"

Vacuum
quick
connector

1020

Network alarm
Oil level security
Additional vacuum quick connector

Dimensions (mm)

800

36
Specifications are subject to be changed without notice

650

Independent vacuum system

SVI

Standby vacuum unit further to NF EN ISO 7396-1 standard


Lubricated rotary vane vacuum pump EVISA MV type
Fitting any existing network
Automatic running independent of the previous plant
Daily automatic running test (patented system)
Possible remote display of the alarms
Integrated drain trap and bacterial filtration
Oil level security
Included suction/exhaust hoses
Mobile version available on request

Characteristics
TYPE

SVI
SVI
SVI
SVI
SVI
SVI

25
40
65
100
150
200

EVISA
EVISA
EVISA
EVISA
EVISA
EVISA

E
E
E
E
E
E

NOMINAL
CAPACITY
m3.h-1

POWER
kW

50 Hz

60 Hz

50 Hz

60 Hz

30
47
65
96
150
190

36
56
78
115
180
228

0,75
1,10
1,50
2,20
3,00
4,00

0,90
1,30
1,80
2,64
3,60
4,80

25
40
65
100
150
200

NOISE
LEVEL
dB(A)

OIL
FILLING
L

MAXI
WEIGHT
kg

60
62
65
67
70
71

1,5
1,5
4,0
4,0
7,0
7,0

100
125
140
150
180
200

Range complying with


2007/47/CE

Dimensions (mm)
A

TYPE
SVI
SVI
SVI
SVI
SVI
SVI

25
40
65
100
150
200

A
860
860
860
860
920
920

B
500
500
600
600
720
720

C
1125
1125
1125
1125
1125
1125

C
1160
1160
1160
1160
1160
1160

D
1
1
11/4
11/4
2
2

B
Suction
D
Exhaust
E

E
1
1
11/4
11/4
2
2

C'

Plant references
SVI 25

SVI 40

SVI 65

SVI 100

SVI 150

SVI 200

914105

914106

916755

916756

SVI 100

SVI 150

SVI 200

Independent

3-ph 400V+N+E

914103

914104

vacuum system

1-ph 230V

914108

914109

MILS

3-phase, 400V/50Hz or
460V/60Hz + Neutral
Other tensions on request

Emergency and back-up systems

Standard power supplies

Accessory and option references


SVI 25

SVI 40

Assembly of 4 wheels (2 swivelling wheels)


Exhaust bacterial cartridge

SVI 65

616757
711103

717263
Specifications are subject to be changed without notice

37

EOLVAC
The ultimate back-up solution system further
to NF EN ISO 7396-1 standard
Monitoring and pneumatic control of the vacuum plant
Vacuum pump driven by pneumatic motor
Lubricated rotary vane vacuum pump EVISA MV type
No need of electrical connection
Integrated bacterial filter and exhaust trap
Included suction and exhaust hoses
Compressed air supply from High Pressure cylinders
(not provided by MIL'S) of medical
or industrial quality
Fitting on any existing vacuum pipeline
Patent system
Range complying with
2007/47/CE

Characteristics

TYPE

NOMINAL
CAPACITY

NOISE
LEVEL

OIL
FILLING

m3.h-1

dB(A)

FILTRATION

AIR
CAPACITY**

PRESSURE
SUPPLY

REGULATION
RANGE

LEAKAGE
RATE *

WEIGHT

m3.h-1

bar

mbar

Nl/h

kg

- 300 / - 600

1.9

180

EOLVAC E100
96
75
4
FD 130 S
216
7
* Leakage rate of the monitoring and pneumatic control.
** With 9 cylinders B50 / 200 bar type, either 90 m, continuous running time is 25 minutes.

Process sequence :
Process sequence :
Industrial quality compressed air supply Medical quality compressed air supply
Hospital vacuum
network

Monitoring
and pneumatic
control

HP cylinders
of industrial
air quality

Hospital medical
air network

Monitoring
and pneumatic
control

Bacterial
filtration

Vacuum pump
with pneumatic
motor

Hospital vacuum
network

Exhaust

HP cylinders
of medical
air quality

Bacterial
filtration

Vacuum pump
with pneumatic
motor

NB : in this process, leakage rate of the monitoring


and pneumatic control is absorbed by the hospital
medical air network.

38
Specifications are subject to be changed without notice

Exhaust

Pneumatic vacuum plants


for medical applications
Dimensions (mm)

1005

909

3/4

1006

Emergency and back-up systems

11/4

Plant references

EOLVAC

industrial quality air supply

820129

EOLVAC

medical quality air supply

820452

MILS

E100

39
Specifications are subject to be changed without notice

PS
Characteristics
NOMINAL
CAPACITY
L.min-1
50 Hz
60 Hz
106
120
168
205

PS 7V
PS 12V

RELATIVE
VACUUM
mbar

MOTOR
POWER
W

-900
-900

250
360

ROTATION
SPEED
rpm
50 Hz
60 Hz
1425
1745
1425
1745

Evacuation time curves

NOISE
LEVEL
dB(A)
50 Hz
57
57

WEIGHT
kg
60 Hz
58
58

Standard power supply

Time (s)

Electric supply : 1-ph 230V - 50/60 Hz

135
120
105
PS 7V (50 Hz)
90

PS 12V (50 Hz)

75
60

1
Suction filter with
paper, polyester
or activated
carbon cartridge

45
30
15
0
0

9
9

100

200

300

400

Evacuation time with a

500

600

20 L

700

800

900

receiver

Standard configuration example


PS piston vacuum pump
PA suction filter

40
Specifications are subject to be changed without notice

1000

Pressure (mbar abs.)

2
Check valve

Oil-less piston vacuum pumps

Suitable for many types of applications in dry and wet environments


Oil-less running
Compact construction and low noise
Direct coupling
Low energy consumption
Optional air filter

Dimensions (mm)
PS 7V / PS 12V
J

Exhaust silencer

D
4x7
=

A
B

A
PS 7
203,5
PS 12
223
* : female connection

B
240
275

D
198
242

E*
G
G 1/4 112
G 3/8 118

H
162
162

J
40
40

K
41
52

PS 7V

PS 12V

416085

416094

PS 7V

PS 12V

Accessory and option references

Fitted air filter

25PA : 619068

38PA : 619069

Check valve

670175

618996

Adjusting valve and vacuometer

670176

PA : paper

Atmospheric pressure solenoid valve


Suction hose

MILS

1-ph 230V

Vacuum pumps

Pump references

618997
359791

MF 1/4 : 670478

MF 3/8 : 618981

41
Specifications are subject to be changed without notice

ARICA 3VK to 100V

ARICA 3VK and 6VK

ARICA 16V, 26V and 40V

ARICA 61V, 80V and 100V

Characteristics
Nominal capacity
m.h-1

1-ph 230 V

50 Hz
4
7
10
16
25
40

3VK
6VK
11V
16V
26V
40V

60 Hz
4.8
8.4
12
19
29
46

Nominal capacity
m.h-1

3-ph 400 V

50 Hz
10
16
25
40
60
80
100

11V
16V
26V
40V
61V
80V
100V

60 Hz
12
19
29
46
70
90
115

Motor power
kW
50 Hz
60 Hz
0.25
0.30
0.30
0.36
0.37
0.45
0.66
0.72
0.75
0.90
1.50
1.80

End
vacuum
mbar abs.

Motor power
kW
50 Hz
60 Hz
0.37
0.45
0.55
0.66
0.75
0.90
1.50
1.80
1.50
1.80
2.20
2.70
3.00
3.60

End
vacuum
mbar abs.

100
100
120
120
120
120

120
120
120
120
120
120
120

Rotation speed
rpm
50 Hz
60 Hz
1400
1680
1400
1680
1400
1700
1400
1700
1400
1700
1400
1700

Noise
level
db(A)

Weight
kg

58
59
64
63
65
68

6.5
11.5
15.5
29.5
29.0
40.0

Rotation speed
rpm
50 Hz
60 Hz
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700
1400
1700

Noise
level
db(A)

Weight
kg

64
63
65
68
70
72
75

14.0
27.5
28.5
37.5
66.0
71.0
87.0

Dimensions (mm)
ARICA 3VK / 6VK

A4
A4

B3
B3

3VK
6VK

A2
A2
AA

A
220
278

A1
60
92

A2
80
89

A3
10
16

A4
30
36

B
160
185

42
Specifications are subject to be changed without notice

B1
117
132

174

167

4 4HOLES
trous 7
7
B2
B2
B1
B1
BB

A3
A3

182
SUCTION
G 1/2

Silencer
Silencieux

C2
C2
A3
A3
A1
A1

304

EXHAUST
REFOULEMENT

C1
C1
CC

SUCTION
ASPIRATION

ARICA 11V

12

7
90

80

112
136

B2
100
112

B3
70
82

C
143
170

C1
121
127

C2 Suct.
124 1/8"
148 3/8"

Oil-free rotary vane vacuum pumps

Oil-free rotary vane vacuum pumps


Running and maintenance low costs
Compact assembly under box for intensive cooling and total protection (Arica 16V to 100V)
Low noise

Pump references
3VK
816596

1-ph 230V
3-ph 400V

6VK
816597

11V
823710
823703

16V
823711
823704

26V
823712
823705

40V
823713
823706

11V
51PA *
357947
712931

16V
76PA
623775
723760

26V
40V
76PA
100PA
706190 714975
712926 715394
1/2"
702434
363032

61V

80V

100V

823707

823708

823709

Optional accessory references


3VK
25PA *
714926

Fitted suction hose


Non fitted adjusting valve
Non fitted vacuum gauge
Adjusting valve and vacuum
gauge dia. 40 cross mounted

1/4"
363031

Fitted check valve


400V
230V
230V
400V
Dmarreurs
with LG7 control 230V
board
230V

80V
126PA
619888
723758

100V
201PA
623776
723759

714927

770581

770582

723756

723757

MF1/4"
670175

MF1/2"
670583
770573
770495

MF3/4"
670584
770495
770496
770503
710422
710430
710428

MF1"
618457
770496
770497
770632
710423
710431
710436

770497
770498

MF1"1/2
623777
770498
770499

710424
710432

710425
710433

3-ph
TRI 3-ph
MONO 1-ph
TRI 3-ph
TRI 3-ph
MONO 1-ph

770631
710421
710429
770471

* It is advised to equip the pump with a hose for easier change of the cartridge

Dimensions (mm)
ARICA 16V / 26V / 40V

ARICA 61V / 80V / 100V


B

A
E

363

C D

202

16V
26V
40V

A
412
412
484

16

A1
148
148
207

A1

B
206
206
230

C
244
244
276

E
1/2"
3/4"
294 1"

382

132

A2
E

MILS

Direct starters
without
regulation

61V

Vacuum pumps

Fitted complete paper air filter

6VK
38PA *
362243
618981
703790

28

305

61V
80V
100V

A
682
712
810

30

10

348

A1

160

A1
76
76
174

A2
56
56
154

C
E
341 1"
348 1"
348 1"1/2
43

Specifications are subject to be changed without notice

SIRELLA
Oil-free technology
Characteristics
Nominal capacity
m.h-1
SIRELLA
SIRELLA
SIRELLA
SIRELLA

50 Hz
112
162
251
342

130
180
250
350

60 Hz
132
194
300
412

Motor power
kW
50 Hz
3
4
5.5
7.5

60 Hz
3.6
4.8
6.6
9

End
vacuum
mbar abs.

Continuous
vacuum
mbar abs.

50
50
50
50

150
150
200
200

Rotation speed
tr.min-1
50 Hz
2850
2850
2850
2850

60 Hz
3420
3420
3420
3420

Noise
level
db(A)

Weight
kg

76
77
78
79

240
250
460
480

Capacity pressure curve and average evacuation time (50 Hz)


Average evacuation time
Flow rate (m3.h-1)
350

Absolute pressure (mbar)

Receiver 1000 L

300

250

1000

800

600

200
400
150
200
150

100

50
0
0

200

10

15

20

SIRELLA 130
SIRELLA 180

400
600 800 1000
Absolute pressure (mbar)

30

40

50

60

70

80

90 100
Time (s.)

SIRELLA 250
SIRELLA 350

Pump references
3-ph 230/400V
3-ph 400V

SIRELLA 130
818222

SIRELLA 180
818223

SIRELLA 250

SIRELLA 350

818224

818225

Accessory and option references


Adjusting valve fitted on T-square (without filter)
PA : paper
Fitted suction filter PO : polyester
CH : carbon
Fitted vacuum gauge
Suction hose
400V 3-ph
Without control
panel
230V 3-ph
Direct starter
With LG7 start and 400V 3-ph
stop system
230V 3-ph
Constant vacuum solenoid valve
MB150S gear box oil
44
Specifications are subject to be changed without notice

SIRELLA 130
SIRELLA 180
SIRELLA 250
SIRELLA 350
723341
713842
201 PA
619891
251 PA
623342
201 PO
619892
251 PO
623343
201 CH
619893
251 CH
623344
617536
(45x1500)
723345
(63x1500)
723346
770498
770499
770500
770499
770500
710425
710426
713746
710433
710434
619894
619895
620516
623260
0.8 l. per pump
1.4 l. per pump
1 litre can
2 litre can
619626
619627

Claw vacuum pumps


Working principle

Claw vacuum pumps


Very good efficiency
Contact-free compression
Oil-free compression
Air cooling
Low maintenance

Dimensions (mm)
B
Suction

Vacuum pumps

Exhaust

Hot air outlet

4 holes M10

MILS

Cooling air

SIRELLA
SIRELLA
SIRELLA
SIRELLA

130
180
250
350

A
840
850
1090
1090

A'
660
660
1040
1040

B
450
450
545
545

B'
400
400
495
495

C
665
665
750
750

D
F 1"1/2
F 1"1/2
F 2"
F 2"

E
M 1"1/2
M 1"1/2
M 2"
M 2"

Specifications are subject to be changed without notice

45

KAV

Compact design
No contamination (without oil)
High efficiency
Low maintenance
Horizontal or vertical axis mounting
For air, non explosive or non harmful gases or gas mixtures
Fluid and ambient air temperature must not exceed 40C

Characteristics (50 Hz)


SINGLE IMPELLER
POWER
V and M1 : single stage
B1 : double stage
kW
Y006V 1-ph/3-ph 230/400V
0,38
Y011V 1-ph/3-ph 230/400V
0,90
Y020V 1-ph/3-ph 230/400V
1,50
Y030V 3-ph 230/400V
2,20
X40B1 3-ph 230/400V
2,20
X06M1 3-ph 400
2,2/3/4
X08M1 3-ph 400
3/4/5,5/7,5
X11M1 3-ph 400
5,5/7,5/
9,2/11/15
60 Hz on request

NOISE
LEVEL
dB(A)
58
64
68
70
72
71,6
77,4
81,8

WEIGHT
kg
13
16
24
32
32,5
35,2
68
98,5

TWIN IMPELLER
B2 : double stage
M2 : single stage
X05B2 3-ph 400
X06B2 3-ph 400
X08B2 3-ph 400
X11B2 3-ph 400
X09M2 3-ph 400
X10M2 3-ph 400
X11M2 3-ph 400

POWER
kW
2,2/3/4
4/5,5
5,5/7,5/9,2
11/15/18,5
9,2/11/15/18,5
11/15/18,5
11/15/18,5/22
1 2 3
Suction filter and
safety valve on
T-connector,
exhaust silencer

Capacity - pressure curve (50 Hz)

11

15
11

18.5
22

9.2
15

X11 M2
18.5

11

X10 M2

5.5

11

15

7.5

15
9.2

18.5

Flow rate (m3.h-1)


1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600

11

X11 B2

5
Electronic vacuum
adjusting valve fitted on T-connector

500

18.5

X09 M2
X11 M1

5.5

400

300

7.5
9.5

5.5

X08 B2

200

2.2

150

2.2

5.5

X06 B2

120
100

3
3
7.5

X08 M1

80

X06 M1

Y030V

60

X05 B2

40

Y020V
X40 B1

20
10
0

Y011V
Y006V

460

4
Non return valve

400

300

200

Pressure (vacuum in mbar)

46
Specifications are subject to be changed without notice

100

Single impeller
Twin impeller

6
P.I.D. vacuum
adjusting valve fitted on T-connector

NOISE
LEVEL
dB(A)
74
75
80,3
85,9
86,1
87,7
89,3

WEIGHT
kg
43,5
61,5
110,5
172
158
163
186,5

Oil-less side channel vacuum pumps


Dimensions (mm)
Y006V to Y030V / X06M1 to X11M1 / X40B1

X05B2 to X11B2

X09M2 to X11M2

B
B
I
K

SINGLE IMPELLER
TYPE
A
Y006V
Y011V
Y020V
Y030V
X40B1
X06M1
X08M1
X11M1

250
286
325
373
350
376
454
540

I and O

257
306
345
383
370
443
542
645

205
225
260
290
245
290
448
509

230
255
296
325
270
325
478
539

256
261
323
377
458
386
550
638

85
95
115
140
235
140
300
300

11/4
11/2
2
2
11/2
2
3
4

TWIN IMPELLER
TYPE
A
X05B2
X06B2
X08B2
X11B2
X09M2
X10M2
X11M2

366
398
500
593
492
516
542

I and O

444
474
698
813
610
623
650

260
290
448
509
478
478
510

570
703
854
1000
850
850
870

115
140
300
300
500
500
500

55
59
82
91
112
112
110

2
2
3
4
130
130
130

Side channel vacuum pump references

Accessory and option references


SINGLE IMPELLER RANGE
1
2
4

5
6

Y006V

Y011V

Y020V

Y030V

X40B1

X06M1

X08M1

X11M1

609454
609455
609456
609455
609456
619921
361050*
619937
619938
620259
620260
619938
619939
Upon
request
Safety valve fitted on T
619932
619933
619934
619933
619934
619935
619936
Non-return valve
Suction hoses
L:1200-MF1"1/4 L:1200-MF1"1/2
L:1500-MF2"
L:1200-MF1"1/2 L:1500-MF2" L:1500-MM3" L:330-MM4"
712927
712928
712929
712928
712929
719925
719926
Sound-proofing hood
425023
425024
425025
425055
425056
425057
425056
425057
425059
425060
Silencer
Flow converting valve
electrical version 230V - 1ph - 50Hz
425090
425092
Flow converting valve
electropneumatic version 230V - 1 ph - 50 Hz / 10 bar maxi
425091
425093
621292
621293
621294
621293
621294
621295
621296
Electronic vacuum valve on T
621297
621298
621299
621298
621299
621300
621301
P.I.D. vacuum valve on T

Suction filter

TWIN IMPELLER RANGE


1 Suction filter
2 Safety valve fitted on T
4 Non-return valve

Suction hoses

X05B2

X06B2

619922
619939
619934
L : 1500 - MF 2"
712929

Sound-proofing hood
3 Silencer
5 Electronic vacuum valve on T
6 P.I.D. vacuum valve on T

* To be fitted on pipeline

425057
621294
621299

X08B2

X11B2

X09M2

619923
Upon request
619935
L : 1500 - MM 3"
719925
425026
425059
621295
621300

361050*
619941
619936
L : 330 - MM 4"
719926
425027
425060
621296
621301

361311*

X10M2

Vacuum pumps

3-ph
1-ph
3-ph
1-ph
3-ph
1-ph
3-ph

TWIN IMPELLER RANGE

MILS

SINGLE IMPELLER RANGE

Power (kW) Y006V Y011V Y020V Y030V X40B1 X06M1 X08M1 X11M1 X05B2 X06B2 X08B2 X11B2 X09M2 X10M2 X11M2
400V
0,38 416087
230V
0,38 416097
400V
0,9
416088
230V
0,9
416098
400V
1,5
416089
230V
1,5
416099
2,2
416090 425040 425000
425012
400V
3
425001 425003
425013
4
425002 425004
425014 425015
5,5
425005 425007
425016 425017
7,5
425006 425008
425018
9,2
425009
425019
425042
11
425010
425020 425043 425046 425086
15
425011
425021 425044 425047 425087
18,5
425022 425045 425048 425088
22
425089

X11M2

361312*
425064*
No available
L: 330 - MM 5"
721186
425028
No available
621302*
621303*

Specifications are subject to be changed without notice

47

EVISA MV
Lubricated rotary vane vacuum pumps, reliable
and robust design for low or medium vacuum.
NOMINAL
CAPACITY
m3.h-1

E17.2
E25.2
E40.2
E65.2
E100.2
E150.2
E200.2
E300.2
E350.2
E400.2
E500.2
E600.2

PNEUROP
CAPACITY
m3.h-1

50 Hz

60 Hz

50 Hz

60 Hz

17
30
47
65
96
150
190
288
360
426
513
632

20
36
56
78
115
180
228
345
432
511
616
758

16
28
41
63
94
147
185
263
341
410
496
597

19
33
49
75
112
176
222
315
409
492
595
716

END
VACUUM
mbar
WITH
GAS BALLAST

3
3
3
3
3
3
3
3
3
3
3
3

MOTOR
POWER
kW

ROTATION
SPEED
rpm

50 Hz

60 Hz

50 Hz

60 Hz

0,55
0,75
1,10
1,50
2,20
3,00
4,00
5,50
7,50
9,00
11,00
15,00

0,66
0,90
1,30
1,80
2,64
3,60
4,80
6,60
9,00
10,80
13,20
18,00

1000
1450
1450
1450
1450
1450
1450
1450
967
967
967
967

1200
1740
1740
1740
1740
1740
1740
1740
1160
1160
1160
1160

NOISE
LEVEL
dB(A)

OIL
FILLING
L

WEIGHT

59
60
62
65
67
70
71
73
74
74
74
75

1,5
1,5
1,5
4
4
7
7
7
10
10
10
10

34
38
52
75
85
106
125
200
355
385
430
474

kg

Average evacuation time (50 Hz)


Absolute pressure (mbar)

Absolute pressure (mbar)

1000 L receiver
1000
1000 l
receiver

100

10

10

12

E17.2
E25.2
E40.2
E65.2
E100.2
E150.2

800
600
400
200
150
100
50
40
30
20
10

1
0

1000

14 16 18
Time (min.)

E200.2
E300.2
E350.2
E400.2
E500.2
E600.2

10 15 20 30 40 50 60 70 80 90 100 110 120 130 150 165 180 200


Time (s.)

Capacity - pressure curve with gas ballast (50 Hz)


Flow rate (m3/h)

0,1

0,5

5 6 7 8 9 10

20

30

40

60

80 100

200

300 400

700
600
500

600 8001013 mbar

E600.2
E500.2
E400.2
E350.2
E300.2
E200.2
E150.2

400
300
200

E100.2

100
90
80
70
60
50

E65.2

40

E40.2

30

E25.2

20

E17.2
10
9
8
7
6
5
4
3
2

48

0,1

0,5

1
0,1

Specifications are subject to be changed without notice

5 6 7 8 9 10
-1

20

30

40

60

80 100
-10

200

300 400

600 800 1013 mbar


-100 kPa

Absolute pressure

Lubricated rotary vane vacuum pumps


Built for medical applications
Suitable for high water vapour tolerance
Continuous running from atmospheric pressure
to end vacuum
Air cooling
Standard motor coupling
PF55 motor - F class IE2
Delivered with MV99S synthetic oil filling

Standard power supplies

Cooling air

F
D

Suction

50 Hz 60 Hz
V10% V10%
1-ph
230
265
3-ph - E17.2 to E300.2 230/400 265/460
3-ph - E350.2 to E600.2 400
460
Special supplies on request

I
V
W

E17.2 E25.2

E65.2 E100.2 E150.2

A
H

I
M

H
M

E
S

Vacuum pumps

M
H

Dimensions (mm)
E17.2
E25.2
E40.2
E65.2
E100.2
E150.2
E200.2
E300.2
E350.2
E400.2
E500.2
E600.2

A
535
535
620
730
780
800
890
1060
1360
1400
1460
1655

B
296
296
296
385
385
504
504
584
680
680
680
680

C
276
276
276
334
334
401
401
421
544
544
544
544

C
290
290
290
379
379
415
415
436
614
614
614
611

D
60
60
60
67
67
108
108
145
145
145
145
145

E
97
97
126
120
120
113
149
259
260
331
364
411

Dimensions without base frame


F
G H H I
J
K
212 253 123 - 148 190 15
212 253 123 - 148 190 15
212 253 152 152 185 190 15
270 317 230 - 243 245 15
270 317 230 - 269 245 15
375 364 260 - 246 343 20
375 364 295 295 266 343 20
450 386 363 363 318 412 25
510 510 408 458 376 462 30
510 510 477 477 376 462 30
510 510 512 512 376 462 30
512 510 558 558 376 462 30

L
373
373
402
600
600
600
635
820
814
884
918
965

M
M8
M8
M8
M10
M10
M10
M10
M10
M10
M10
M10
M10

M
M8
M8
M8
M8
M8
M10
M10
M10
M10
M10
M10
M10

E
1
1
1
11/4
11/4
2
2
2
DN80
DN80
DN80
DN80

Dimensions with base frame


S
T
V
W
X
Y Z
1 150 205 285 270 300 10
1 150 205 285 270 300 10
1 150 205 285 270 300 10
11/2 150 290 370 335 365 11
11/2 150 290 370 335 365 11
2 150 290 370 430 460 11
2 150 290 370 430 460 11
2 150 440 500 590 620 12
G3 200 440 500 790 820 12
G3 200 440 500 790 820 12
G3 200 440 500 790 820 12
G3 200 440 500 790 820 12

Specifications are subject to be changed without notice

MILS

E40.2 E200.2 E300.2


E350.2 E400.2 E500.2 E600.2

L
E

4 x Z

X
Y

L
I

Exhaust

Oil

49

EVISA MV

1
Suction filter with
paper, polyester or
activated carbon
cartridges

Pump references
2
Straight-through
filters

1-ph 230V 50 Hz
With MV99S oil filling

3-ph 230/400V 50 Hz or 400V 50 Hz


3-ph 220/380V 60 Hz

Accessory and option references


3
Vacuum gauge
adaptable
on filter cap

PA : paper

Suction filter

PO : polyester

CH : carbon
3

4
Safety valve
mounted on
T-square

Fitted vacuum gauge


Fitted complete gas ballast
Additional filter for gas ballast

Adjusting valve fitted on T-Square (without filter)


Oil level safety (OLS)

Suction hose with check valve (except E350 to E600)

Base frame assembly

see page 62

for 1 pump
Elevated base frame with retention vat
Base plate for LG7 box
Monitoring of temperature
Mechanical thermostat with oil level safety

5
Suction hoses

Digital display panel + PT100


Direct starters

without control panel

3-ph 400V
3-ph 230V
1-ph 230V

6
Base frame
assembly

7
Liquid trap
for vacuum pump
protection

8
Vertical vacuum
receiver

50
Specifications are subject to be changed without notice

with LG7 start and

3-ph 400V

stop system

3-ph 230V
1-ph 230V

Star/delta starter 400V+N+E


with : 1 electric atmospheric pressure valve

230V - 50Hz

or 1 pneumatic atmospheric pressure valve

6 bar

Liquids trap protecting vacuum pumps against liquids

see page 61

Vertical vacuum receivers

see page 63

Accessories
Accessoires
EVISA
E17.2
816676

E17.2

E25.2

E40.2

815178

815179

814007

814008

822567

822570

870730

870731

815720

822193

823481

823157

823158

823535

823159

823160

E40.2

E65.2 E100.2 E150.2 E200.2 E300.2 E350.2 E400.2 E500.2 E600.2

E25.2

76 PA : 715347

E65.2 E100.2 E150.2 E200.2 E300.2 E350.2 E400.2 E500.2 E600.2

100 PA : 714975

126 PA : 706192

817153

201 PA : 715350

817964

817154

818167

301 PA : 717369

76 PO : 715348

100 PO : 714976

126 PO : 709398

201PO : 715351

301 PO : 717370

76 CH : 715349

100 CH : 714977

126 CH : 710521

201CH : 715352

301 CH : 717371

617536
770826

770800

722913

716463

617708
M 3/4
713840

M 1
714979

M 11/4
713841

616111
770151

714980

616112

770152

617710

623337

623314

770154

670805

617610

717435

M 2
713842

622886

670804

717128

617709

670806

617611

617833
616595

618251

617612

617613

For ON/OFF starters : 617407


623315

623319

618547

623338

623317

618255
770496
770503
710422
710430
710428

770496
770497

770497
770498

770498
770499

770499

770500

770501

719237 719238

770500

770504
710423
710431

710424
710432

710425
710433

710426

713746

719239

710434

710435
718389

718390

718391

718392

617496
618257

MILS

Special oils for vacuum pumps

Vacuum pumps

770495

100% synthetic oil for continuous running


Synthetic oil
MV99S

2 litre can
362660

5 litre can
362661

Jerrican 20 kg
363149

170 kg cask
362662

Mineral oil for standard running


Mineral oil
MV100M

2 litre can
363044

5 litre can
363045
51
Specifications are subject to be changed without notice

ANTIGUA

Liquid ring vacuum pumps


Low water consumption with partial water recycling system
Capable of handling draw-in liquids and dust
Low maintenance

Characteristics
NOMINAL CAPACITY

POWER

m3.h-1

kW

50 Hz

60 Hz

50 Hz

27
37
0.75
ANTIGUA S26
49
58
1.5
ANTIGUA S51
89
110
3
ANTIGUA S126
152
198
4
ANTIGUA S161
230
280
5.5
ANTIGUA S251
290
360
7.5
ANTIGUA S325
* consumption for a pressure less than 200 mbar abs.

NOISE
LEVEL

WEIGHT

WATER CONSUMPTION*

kg

L/min
opened
with
range
separator
4
2
4
2
8
4
16
8
16
8
20
12

60 Hz

dB(A)

50 Hz

60 Hz

1.1
2.2
4.8
6
8
13.2

68
68
67
65
65
70

21
27
51
82
120
145

21
30
56
110
125
185

Capacity - pressure curve (50 Hz/60 Hz)

1
Water flow
regulation

Flow rate m3.h-1


400
380
360
340
S325 - 60Hz

320
300
280

S325 - 50Hz
S251 - 60Hz

260

2
Suction hoses

240
220
S251 - 50Hz

200

S161 - 60Hz

180
160

S161 - 50Hz

140

3
Non return valve

120
100

S126 - 60Hz

80

S126 - 50Hz

60

S51 - 60Hz
S51 - 50Hz
S26 - 60Hz
S26 - 50Hz

40
20
0
10

40

60 80 100

200

400

Water supply

52
Specifications are subject to be changed without notice

1000 mbar Absolute pressure

4
Air/water
separator trap

Liquid ring vacuum pumps


Dimensions (mm)
ANTIGUA S26 - S51 - S126 - S161

ANTIGUA S251 and S325


B1

A = A1
G

A = A1

B1

G
C1
C
C1
C
J
1/4
Ub

A
H

D
B

C K

1/4
Ub

D
B

ANTIGUA
ANTIGUA
ANTIGUA
ANTIGUA
ANTIGUA
ANTIGUA

S26
S51
S126
S161
S251
S325

WITHOUT SEPARATOR
A
B
C
338
182
210
366
182
229
424
250
280
515
338
342
599
365
365
704
425
412

WITH
A1
338
366
424
515
599
704

SEPARATOR
B1
C1
200
460
205
470
320
650
390
750
405
880
540 1100

D
125
140
160
190
216
216

E
100
100
140
140
140
178

F
70
74
110
180
200
240

G
88
109
95
143
159
92

H
20
20
5
8
15
0

I
43.5
44
33
47
90
104

J
80
90
100
112
132
160

K
68
81
138
172
195
202

A Ub
9
1/4"
9
1/4"
12 1/4"
12 1/2"
12 1/2"
15
1

C
1"
1"
1"1/4
1"1/2
DN50
DN65

Liquid ring vacuum pump references


S51
819949
819955

S126
819950
819956

S161
819951
819957

S51

S126

S161

S251
819952
819958

S325
819953
819959

Accessory and option references


S26

S251
DN50 (2")
619965
16 l/min
357042
8 l/min
357039

Inlet/outlet flange adaptor


Water flow regulation

without separator

with separator
1

Liquid separator with hose


for a partial water recycling
Strainer on water inlet with without separator
security pressure gauge * with separator

4 l/min
357038
2 l/min
357041
619960
621363
621362

Inlet non-return valve


LG7 device
Cavitation protection hose**

719971
818278
818277
619974

619961
621364
621363

619962
619968
621364

Suction and exhaust M/F hoses


25 x 1200
715394

8 l/min
357039
4 l/min
357038

AIR/WATER separator trap

PS65
707604

35 x 1200
712928

619963
619970
621365

foreseen flange adaptator


45 x 1500
712929

719972
818279
619975

S325
DN65 (2")
619966
20 l/min
357043
12 l/min
357040

Vacuum pumps

S26
819948
819954

MILS

50Hz
60Hz

719973
foreseen flange adaptator
619976

PS130
707605

PS320
707606

* Water flow regulation non included


** Cavitation protection hose : only for end vacuum running and included with water flow regulation separator
Specifications are subject to be changed without notice

53

Our bacterial filters are made up of


an opaque pot/filter (1) in which a
cartridge for bacteria (2) equipped
with a baffle (3) is installed.
Filter opacity prevents bacterial
proliferation in the cartridge.

higher than 99,99% for 0,5m particles. This cartridge media is pleated
in order to guarantee a maximum
exchange area for a longer service
life and an unequalled pressure drop.

Network

Pumps

The cartridge is covered by the baffle


which captures liquid and solid
heavy particles. Gravity makes these
particles fall to the bottom of the
filter. A sterilisable Pyrex jar (4)
is mounted under the filter in order
to scavenge particles.

The cartridge is made up of borosilicate microfibres and its filtration


rating prevents bacteria and living
microorganisms to penetrate.
It meets the sodium flame test which
guarantees penetration efficiency

Parallel duplex
filtration

Schedule for capacity corrections for a network at 650 mbar relative


Pressure in mbar
Correction coefficient

Free air
0,4

-400
0,6

-500
0,7

-650
1

-800
1,6

-900
2,8

Simple filtration without by-pass


Twin pot with bacterial filter
Wall fixation

Characteristics and dimensions (mm)


FD30S
FD65S
FD130S
FD320S
FD600S
FD1000S

Flow rate (m .h
30
65
130
320
600
1000
3

-1

A
170
170
241
258
258
725

54
Specifications are subject to be changed without notice

B
440
565
590
635
900
908

C
125
125
145
220
220
298

E
F3/4
F3/4
F11/4
F2
F2
DN 80

Bacterial filtrations and


vacuum protection drip pots
Simple filtration with by-pass
A

Twin pot with bacterial filter


2 three-way valves with welding sleeve on inlet
and outlet
By-pass tube
Wall fixation
E

E
B

Characteristics and dimensions (mm)


FD30B
FD65B
FD130B
FD320B
FD600B
FD1000B

Flow rate (m .h
30
65
130
320
600
1000
3

-1

A
420
430
490
700
700
1191

B
375
495
520
560
840
955

C
145
145
175
260
260
410

E
F3/4
F3/4
F11/4
F2
F2
DN 80

Parallel duplex filtration

Characteristics and dimensions (mm)


C

FD2000DP
B

MILS Bacterial filtrations

2 assemblies pot/bacterial filter, parallel mounting with


2 three-way valves on inlet and outlet
Wall fixation

250cc
Mini for
cartridge
removal

100

FD60DP
FD130DP
FD260DP
FD640DP
FD1200DP
FD2000DP

Flow rate (m .h
60
130
260
640
1200
2000
3

-1

A
600
805
805
1055
1055
1003

B
375
495
520
560
840
1174

C
205
260
260
365
365
823

E
F3/4
1
F11/4
F2
F2
DN80

55
Specifications are subject to be changed without notice

Simple filtration without by-pass, simple filtration with by-pass


and parallel duplex filtrations
Filtration reference
FD..S type
FD..B type

FD..DP type
Cartridge type
Cartridge with seal
Cartridge with deflector and spring
500cc
PYREX jar
1000cc
PR30
Lowest level
drip pot
PR60

FD30..
812060
811848

FD65..
812061
811849

FD130..
812062
811850

FD320..
812063
811851

FD600..
812064
811852

FD1000..
814914
814915

FD60..
814967
B2x4
359368
614026

FD130..
814968
B2x10
359351
614027

FD260..
FD640..
814969
814970
B2x10
B3,5x9
359351
359374
614027
614028
351525
351526
712068
706547

FD1200..
814971
B3,5x19
359375
614029

FD2000..
820146
B7x9
360609

MIND : foreseen 2 cartridges for duplex filtrations

Lowest level drip pot for vacuum network


Fitted pot to the flow rate to be connected at the lowest point of the collector
3

-1

Flow rate in m .h
Welding sleeves for inlet/outlet
Pot without by-pass
Pot with by-pass

PPB65
65
I.D. 22
707611
707710

PPB130
130
I.D. 32
707612
707711

PPB320
320
I.D. 52
707613
707712

PPB600
600
I.D. 52
712313
712314

PPB

Water/air separator for LABOVAC plants


Water/air separator fitted to the air flow rate of the liquid ring vacuum pump
Setting at the pump exhaust
Flow rate in m3.h-1
Welding sleeves for inlet/outlet
Welding sleeves for sewer outlet
Complete set

PS65
65
I.D. 22
I.D. 18
707604

PS130
170
I.D. 32
I.D. 32
707605

PS320
600
I.D. 52
I.D. 42
707606

PS

sewer

Drain trap with visible level alone


Liquid drain trap for vacuum pump protection
Flow rate in m3.h-1
Welding sleeves for inlet/outlet
References

P60
60
I.D. 22
706570

P120
120
I.D. 32
706571

P
P400
400
I.D. 52
706572

Sterilizable lowest level drip pot


Thermal glass pot for network protection to be connected at
the lowest point of exhaust collector
Capacity in cm3
Inlet/outlet welding sleeves
Complete set

BPB250 BPB500 BPB1000 BPB5000


250
500
1000
5000
I.D. 22 I.D. 22 I.D. 22 I.D. 22
603230 606262 606264 609993

56
Specifications are subject to be changed without notice

Lowest level drip pot

Notes

57

PROCOM, CYCLIC 2020,


MILLENIUM,
MIL'S is offering several solutions for control and regulation of the vacuum plants for medical applications.
2 regulation modes are proposed :
ON/OFF mode : starts ands stops the motor at pre-set values. This mode is advised for usual low
running operations.
FLEXO mode : starts the motor but stops it only when the pre-set time is reached, independently of
the pre-set values. This mode is advised for usual high running operations, and to avoid too many motor
starts and stops.

Dimensions (mm)
For 4 to 6 motors

For 1 to 3 motors

500

600

300

700

Characteristics

30

270

LG7 control board

REPORT STATUS device


115

70

210

195

230

125

PROCOM 1

CYCLIC 2020

58
Specifications are subject to be changed without notice

MILLENIUM

LG 7

Technology
Managed motors
Managed fluids
Running
Priorities inversion
Control regulation type
Type regulation planning
Hour counter
Running visual display
Maintenance management
Management of premises ventilation
Alarms
Led
Buzzer
Alarms visual display
Dry contact for alarm transfer
Back-up cylinder monitoring
Dew point monitoring
REPORT STATUS device connection
Gases monitoring (CO , CO, O )
2
2
Supply supervision
Display input/output
Screen
RS485 with procedure
Ethernet
Supervision
Measure curves
Data export
 standard equipment  non available

Control and regulation devices


for vacuum
Accessory and option references
REPORT STATUS device for remote alarm transfer (CYCLIC 2020)

contact us

Meter of shielded cable for J-Bus connection (RS 485) from the CYCLIC 2020 electronic cards

060524

to the REPORT STATUS device


Electrical cord with RJ45 connector to remote 4 alarms from the REPORT STATUS box (provide 3 electrical cords for the 12 alarms)

615892

1
REPORT STATUS
device

 PROCOM 2*
Dedicated PLC
1 to 6
Air, Vacuum or O2

 PROCOM 1
Dedicated PLC
1 to 6
Air or Vacuum

 CYCLIC 2020
Dedicated PLC
1 to 3
Air or Vacuum

 MILLENIUM
Dedicated
2 or 3
Air or Vacuum

 LG 7 device
Electromechanical
1
Air or Vacuum

Cyclic or fixed
ON/OFF regulation or FLEXO






Cyclic or fixed
ON/OFF regulation or FLEXO






Cyclic or fixed
ON/OFF regulation or FLEXO






Cyclic or fixed
ON/OFF regulation or FLEXO







ON/OFF regulation or FLEXO



















































Color/touch
MODBUS




* see page 60

16 lines
JBUS





1 line
JBUS





4 lines



















MILS Control and regulation devices




59
Specifications are subject to be changed without notice

Regulation and control device


PROCOM 2
Up-to-date technology, PROCOM 2 touch-screen computer brings a big change in human/machine interaction.
It perfectly matches the running of a vacuum plant equipped with one to six vacuum pumps EVISA type
(lubricated vanes), SIRELLA type (claw and oil-free technology) or ARICA type (oil-free vanes).
Remote monitoring with RS485/Modbus or Ethernet.
USB key for data gathering : curves, parameters and events.

Available curves :
regulation pressure
network pressure
antibacterial filter clogging
pump running graph

Screen display for alarm,


regulation and maintenance
events

Synoptic screen to match in a


wink the complete running of
the vacuum plant

Management of the maintenance


schedule of the vacuum pumps and
the bacterial filtration.

Summary of existing alarms

Many possibilities to customize the vacuum plant


running
60
Specifications are subject to be changed without notice

Accessories

Liquids traps for


vacuum pumps
High efficiency to drain liquids in vacuum pipeline
Plexiglas or polycarbonate cylinder
Wall fixation or direct fitting on machine support

1NG 2NG 3NG


5 type drain traps

Options

Pyrex cylinder
Pyrex bottle fixed under the trap to drain condensates
Mechanical float which stops the vacuum if too much liquid inside
Fitting of an automatic liquid drain under the trap :
Allows to drain the system without stopping the process

Automatic drain

Dimensions (mm) and characteristics


1NG plexiglas or pyrex
polycarbonate
2NG
pyrex
3NG plexiglas or pyrex
4NG polycarbonate** or painted steel*
5
polycarbonate** or painted steel*
6
polycarbonate** or painted steel*

1 and 2 NG type drain trap

C
193
193
318**/229*
318**/229*
403**/327*
403**/327*

Dimensions expressed in mm
D F1 F2 F3
G
H
100 45 45 291 3/4" 4 x 7
25
1"1/4 2 x 7
100 25 45 388 1"1/4 4 x 7
180
2"
194
2"1/2
251
3"
251
4"

Weight
kg
3
5
5
8
8
515 383 14
525 383 14
A'

B'

Automatic drain

3NG 4NG 5 6 type drain trap

220

A
J

F1

Optional flange
(5 and 6 type)

152

500ml : 200
1000ml : 250

349
B
250ml : 160

1000ml : 250

H
F2

500ml : 200

OPTION

Depth : 148
250ml : 160

F3 B

1/2

170

I J
K
10 20 145
10 33 130
10 33 130

MILS Accessories

Flow
m3/h-1 A
B
30 125 320
100 162 420
162 415
280 230 470
465 229 375
650 343 467
650 343 467

Cylinder material

1/2

Optional PYREX bottle

Filtration capacity
Inlet - Outlet
With POLYCARBONATE
CYLINDER

Optional PYREX bottle

m.h-1

without mechanical float


with mechanical float
without mechanical float
With PAINTED STEEL
CYLINDER
with mechanical float
250cc PYREX Bottle mounted under the trap with :
500cc PYREX Bottle mounted under the trap with :
1000cc PYREX Bottle mounted under the trap with :
Flanges

Bracket for wall fixing


Pneumatic automatic drain
Electrical automatic drain
(1)
PLEXIGLAS CYLINDER - (2) PYREX CYLINDER

1NG
30
3/4"
613589(1)
713590(1)
717757(2)
713099(2)

2NG
100
1"1/4
716600
716565
716601(2)
716592(2)

3NG
4NG
280
465
2"
2"1/2
720807
719920
720808
720811
720809
719437
720810
720812
615441
615442
615443

5
650
3"
717786
720813
717740
720814

6
900
4"
721107
721108
721109
721110

DN80
DN100
617513
617514
619907
617512
Automatic drain + control board 816002
Automatic drain + control board 816003
61
Specifications are subject to be changed without notice

Accessories

"SPIREACIER" special
hoses for vacuum
Suction hoses

Special vacuum "SPIREACIER" hoses with 2 rotating nuts


Crimped hose 1/2 - 14 3/4 - 20
600 mm
670633
606086
1000 mm
612919
604422
1500 mm
616362
618264

1 - 25
618265
617372
618266

11/4 - 30 11/2 - 35
670650
618267
607058
606455
610457
618268

2 - 45
618149
606099
607592

21/2 - 64
618956
618957
618661

DN80
618269
617833

DN100
618270
617834

Special vacuum "SPIREACIER" hoses with 2 rotating nuts


Hose by the
1/2 - 14 3/4 - 20 1 - 25 11/4 - 30 11/2 - 35 2 - 45 21/2 - 64
meter
059656
056350
060596
056351
056352
056353
061707
Connections batch* 618271
618082
618083
618084
618085
618086
618958

DN80
061409
618272

DN100
061412
618273

* 2 bushings + clamps and 2 FF rotating nuts + gaskets

BRASS straight unions


MM equal

1/2
350473

3/4
350476

MM

1/2 - 3/4
350474

3/4 - 1
353551

1
350477

11/4
350480

11/2
350482

2
350484

1 - 11/4 11/4 - 11/2 11/2 - 2


350478
350481
350483

Check valve
Brass check valve for vacuum

62
Specifications are subject to be changed without notice

3/8"
654225

1/2"
654226

3/4"
654227

1"
654903

1"1/4
654904

1"1/2
654905

Accessories

Vertical vacuum receivers

All our vacuum receivers are made of steel sheet, painted externally in white RAL 9016.
On request, they can be internally and externally hot zinc-dipped by full immersion.

Characteristics

Equipment

1 inlet and 1 outlet tapped to gas pitch


for standard version, or 2 inlets and
2 outlets in galvanized version.

Available capacities

- 0 to 1013 mbar vacuum gauge,


- Manual drain
- Outlet valve

Available on stock :
500, 1000 and 2000 litres,
On request, short time
300, 800, 1500, 3000 and 5000 litres

References and dimensions (mm)


Z : vacuum gauge

Vertical vacuum
receiver

A
E

D
F

W : manual drain 1/2

Capacity / volume in litres


Receiver alone
with primer
and painting

300

500

800

1000

1500

2000

3000

5000

610593

610594

610595

610596

610597

622340

610599

610600

Receiver with equipment

710601

710486

710487

710488

710489

722341

710602

710603

300

500

800

2000

3000

5000

OPTIONS
Automatic
vacuum
drain
Network valve

A
B
C
D
E

electro-pneumatic

1000
1500
816002

816003
11/2 610854
2 610855
850
850
1000
1200
1635
1820
2140
2100
1390
850
1840
850
410
470
-165
170
170
170
1100
1450
1600
1600
3 feet 120 (16)
F
520
590
620
1140
765
1140
W
11/2
1/2
3/4
1/2
3/4
1/2
X
11/4
11/4
11/2
11/2
2
2
Y
11/2
1
1
-Z
3/4
1/4
1
1/4
1
1/4
Weight kg
70
120
150
210
290
280
Standard receivers in stock Special and horizontal receivers can be fit to the customer's drawing.
Nota : 500, 1000 and 2000 litre receivers can't be galvanized as they are already painted.

MILS Accessories

electrical

11/4 610853
550
650
1545
1800
1345
850
350
150
170
1100
1450

21/2 610856
1200
1400
2970
3670
2660
3280
510
540
160
160
1600
1600
890
3/4
21/2
11/4
11/2
530

1030
3/4
21/2
11/4
2
750

63
Specifications are subject to be changed without notice

Services
MILS,
aware of your imperatives and
requirements, offers all kind of
services to enhance the use you
make of your equipments.
Training
Compose your program from
the numerous available modules,
whether theoretical or practical,
on air, vacuum and of course,
the standard and regulated
environments for our products.

Training

After-sales service

After-Sales Service
From intervention on your premises
to servicing in our factories, from
troubleshooting to maintenance
contract, our technicians will help
you to maintain the performance
of your equipment and will counsel
you on their optimisation.
Lending / Renting
If you want to checkout your
MIL'S technical solution before
committing yourself to a purchase,
we can place by you, hired or
loaned, the equipment you are
interested in.

Lending / renting

64
Specifications are subject to be changed without notice

Dimensioning calculation
and conversion tables
Dimensioning calculation
FLOW RATE
3

PIPE LENGTH (m)

-1

m .h

10

10

20

30

40

50

60

80

100

1/2

15

3/4

25
40
50

60
80

/4

11

100

/2

130

11

180
2

200
250
300

/2

21

340

400
630

1000

Conversion tables

Flow rate calculation further to altitude


The after-specified formula allows to calculate
the pressure further to the altitude.
Mind, this formula is valid up to 50 km altitude.

Vacuum / Pressure
1 mbar

= 0,0295 in Hg

1 bar

= 14,50 psi

1 kPa

= 10 mbar

MILS Services

500

= 0,01 bar

p = 1013 e

h / 7,5

Dimensions
1 mm

= 0,039 in

1m

= 3,281 ft

= 39,37 in

with : p : pressure in hPa


h : altitude in km

Power
1 kW

= 1,341 hp
At
At
At
At

Weight
1 kg

= 2,205 lb

sea level
Mont Blanc mountaintop
Everest mountaintop
average plane flight altitude

Altitude (km)
0
4,8
8,8
15

Pressure (hPa)
1013
560
320
120

Flow rate
1 m3.h-1

= 16,667 L.min-1
-1

1 L.min

= 0,2642 gal.min

= 0,5886 cfm
-1

Temperature
t(F)

65

= 1,8 x t(C) + 32
Specifications are subject to be changed without notice

Useful formulae
Vacuum down grade time of a receiver
The following formula allows to calculate the required time to
down grade of a receiver from P1 pressure to P2 pressure :
t = 2,3 (V / Q) log (P1 / P2)
with : V : receiver capacity in L
Q : vacuum pump flow rate in L.s-1
P1 : original pressure in absolute mbar
P2 : final pressure in absolute mbar
t : evacuation time in s

Water vapour pressure


The following board gives vapour pressure at water level for
temperatures included between 0 and 100 C

Temperature
C
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100

Pressure
mbar
6,11
8,72
12,28
17,05
23,38
31,67
42,43
56,23
73,77
95,84
123,35
157,39
199,17
250,05
311,60
385,47
473,47
578,13
701,01
845,20
1013,33

66
Specifications are subject to be changed without notice

Useful formulae
Dew point : definition
Temperature of a cold wall plunged into a humid
chamber at which the condensation of humidity
present in air appears.

Air humidity

Dew point
C
- 84
- 82
-80
-78
- 76
- 74
- 72
- 70
- 68
- 66
- 64
- 62
- 60
- 58
- 56
- 54
- 52
- 50
- 48
- 46
-44
- 42
- 40
- 38
- 36
- 34
- 32
- 30
- 28
- 26
- 24
- 22
- 20
- 18
- 16
- 14
- 12
- 10
-8
-6
-4
-2
0

ppm (volume)
in air

ppm (weight)
in air

0,263
0,382
0,526
0,737
1,01
1,38
1,88
2,55
3,43
4,59
6,10
8,07
10,8
13,9
18,2
23,4
30,2
38,8
49,7
63,2
80,1
101
127
159
197
246
305
376
462
566
692
842
1021
1236
1489
1791
2147
2566
3061
3638
4316
5105
6025

0,16
2,24
0,33
0,46
0,63
0,82
1,17
1,64
2,13
2,84
3,71
5,01
6,59
8,21
11,6
14,5
18,8
24,2
30,7
39,3
49,7
61,7
79,1
98,6
123
156
189
234
287
351
431
524
635
766
925
1110
1340
1590
1900
2260
2680
3170
3800

Partial vapour
tension
mg/m3
0,189
0,288
0,399
0,558
0,765
1,040
1,420
1,930
2,60
3,48
4,61
6,15
8,00
10,6
13,8
17,8
23,0
29,5
37,8
48
61
77
97
122
151
188
232
288
352
430
527
640
790
940
1140
1360
1640
1950
2300
2780
3300
3900
4600

Relative humidity
at 21C
%
0,00107
0,00155
0,00214
0,00300
0,00412
0,00562
0,00765
0,0104
0,0140
0,0187
0,0248
0,0328
0,0433
0,0567
0,0738
0,0952
0,126
0,160
0,202
0,257
0,325
0,410
0,516
0,646
0,804
1,01
1,24
1,55
1,88
2,30
2,81
3,42
4,14
5,01
6,06
7,29
8,75
10,40
12,8
14,8
17,5
20,7
24,1
Specifications are subject to be changed without notice

MILS Services

Values indicated in the table hereafter correspond to dew points i.e. to the weights
of saturating water vapour per m3 beyond which water condenses into a liquid at
the considered temperature.

67

General conditions of sale


and guarantee - Sales contract
GENERAL POINTS
The orders noted and the commitments taken by the
Representatives or Agents, are only binding on our company
after its WRITTEN ACCEPTANCE.
The orders only become final after forwarding of an acknowledgment of receipt. They imply the acceptance of the present
general conditions of sale notwithstanding any contrary clauses
of our customers that have not been expressly accepted in
writing.
The role of our company consists in manufacturing the equipment. It is not for it to appreciate the appropriateness of the
choice of any equipment as regards its final destination or the
use to which it is allocated.
Any information that we may be led to provide is only given
in the framework of our productions and for information, and
does not consist of indications regarding the choice of the
equipment or the final use for which it is destined. In no case
can our liability be incurred if there is no sale of equipment.
Our activity consists in manufacturing products ordered by
our customers and it is not for us to appreciate the appropriateness of an order for the use to which it is destined by
the purchaser.
The present general conditions and the special conditions
insofar as the latter are not contrary to the present general
conditions and still comply with general contract law and
competition law can be completed by the Customer general
conditions of purchase expressly accepted by the Supplier.
Any derogation to the present general conditions is subject to
our express and written acceptance.
TRANSFER OF OWNERSHIP RESERVATION OF OWNERSHIP
TRANSFER OF RISK
The merchandise shall remain our property up until the full
payment of its price in principal and interest. Failing the payment of the price on the agreed due date, we shall be able to
take back the merchandise, the sale being declared void if
this seems proper to us, and the deposits already paid shall
remain acquired by us in return for the enjoyment of the merchandise from which the purchaser will have benefited.
The purchaser becomes responsible for the merchandise as soon
as it is collected from our factory, the transfer of possession
leading to the transfer of risks. The purchaser undertakes,
consequently, to take out, as at present, an insurance
contract covering the risks of loss, theft or destruction of the
merchandise.
INTELLECTUAL PROPERTY AND KNOW-HOW
FOR DOCUMENTS AND PRODUCTS
All intellectual property rights as well as know-how incorporated
into forwarded documents, delivered products and provided
services shall remain the exclusive property of our company.
STUDIES AND PROJECTS
The studies and documents of any nature passed on or sent
remain entirely our property. They cannot lead to communication
or to execution by a third party.
CANCELLATION OF A CONFIRMED ORDER
The cancellation or termination of an order in the course of
execution for a cause outside our control, including force
majeure, shall render the customer the debtor in respect to
Mils of compensation that, in no case, shall be less than 20%
of the amount of the order, whatever may be its state of
advancement, and any deposit already paid shall be kept as cover.
RETURNS
No merchandise can be returned to the Company Mils without
the agreement of the latter.
DELIVERY AND PRICE
THE DELIVERY IS DEEMED MADE IN OUR FACTORIES OR STORES.
It is made by the direct handing-over to the customer, by
simple notice of availability, or by handing-over to a shipper or
to a carrier appointed by the customer or, failing such
appointment, chosen by us.

68
Specifications are subject to be changed without notice

The delivery times are given for information and are not guaranteed. Delivery delays do not give the purchaser the right
to cancel the sale or to refuse the merchandise. They cannot give
rise to retention, compensation, penalty or damages.
THE PRICES ARE UNDERSTOOD TO EXCLUDE TAX FOR THE
EQUIPMENT NOT PACKED TAKEN IN OUR FACTORIES OR STORES,
THOSE PRICES ARE IN EUROS.
CONDITIONS OF USE
All equipment is delivered accompanied by technical instructions
that we recommend should be followed. If these instructions are
not attached, they will be immediately forwarded on simple
request.
PAYMENT CONDITION
In case of no negotiation before ordering, the payment term
is by swift transfer at reception of invoice, with minimum of
60 net. (Payments are made in euros unless otherwise stipulated in the agreement).
It is expressly agreed and failing timely request for postponement
and granted by us, the failure to pay our invoices by the date
indicated on the said invoices and by the date resulting from the
application of our general sales conditions, if it is after the first
date, shall lead to :
1. the immediate payability on the amounts remaining due,
2. the interests calculated at a rate equal to 10% per year and
any legal costs.
We do not grant discount for early payment, unless it has
been negotiated at the time of the order.
Notification of the customer situation :
In case the deterioration of the customer situation is noticed
by any means and/or certified by a significant delay in payment
or when the financial situation is appreciably different from the
available data, the delivery will be made only in compensation
for an immediate payment.
TRANSPORT
ALL TRANSPORT OPERATIONS, insurance, customs, handling
carried out ARE PAYABLE BY AND AT THE RISKS OF THE PURCHASER who is responsible for checking the shipments on
arrival and for taking action, if appropriate, against the carriers.
In the case of dispatch ensured by us, this shall be made carriage due, full responsibility resting with the purchaser.
Our company, at the request of the customer, shall insure the
merchandise against transport risks, and shall invoice, as a
supplement, the cost of this insurance.
GUARANTEE OF THE EQUIPMENT
OUR MERCHANDISE IS GUARANTEED ONE YEAR, as from the date
IT IS MADE AVAILABLE, against any construction defect or any
fault in the material.
In all cases, if the equipment is used by several teams, the
period of the guarantee is necessarily reduced by half. For the
components that are not of our manufacture, we are not substituted in the conditions of guarantee of the supplier constructor.
The guarantee does not apply to replacements or to repairs that
could result from normal wear of the instruments, deterioration
or accidents due to a defect in surveillance or installation and
improper use. Likewise are excluded from the field of application
of the guarantee, deteriorations resulting from damage during
transport, falls, or violent shocks.
The guarantee is limited to the free replacement, in our
workshops, of the machine pieces or parts recognised as
defective due to material fault or manufacturing defect, with the
exclusion of labour. The pieces replaced remain our property.
The transport costs, the outward as the return journey, are to
be paid by the customer.
The guarantee ceases if the instruments are modified or repaired
outside our workshops. The passage through our workshops

does not lead to the extension of the period of initial guarantee


of the machine. Replacement parts or remade pieces are
guaranteed 6 months, as from the delivery date after our
intervention. The guarantee shall not apply in the event of
non-payment by the customer and he cannot take advantage
of it or postpone his payments.
LOAN OF EQUIPMENT
Our company may have to lend some material for a determined
duration under conditions defined in a loan contract. At the end
of the agreed period, the customer shall notify if the material
on loan will be returned or ordered. In the absence of any
notification within this period, the sale shall be deemed to
be effective, as the customer will be presumed to have accepted
the delivered product.
ELIMINATION OF WASTE
In accordance with article 18 of the decree N 2005-829 of
July 20th, 2005 relating to the composition of the electrical
and electronic equipment, the customer will be responsible
for the financing and organisation of the elimination of waste
from this equipment under the conditions defined in articles
21 and 22 of the said decree. In case of control, the producer
may ask his customer to send him the documents establishing
he fulfils, as regard this equipment, all the obligations transferred with the sales contract.
If the customer fails to forward these documents, he will be
presumed to be liable for non-fulfilment of the obligations he
is responsible for and the manufacturer reserves the right to
ask him compensation for any damage that he could suffer
thereby.
INSURANCE COVERING OUR LIABILITY
Our company has taken out an insurance policy covering the
pecuniary consequences of our legal liability and this in the
following way :
1. Before delivery of the products :
Bodily injuries 6 100 000
Consequential moral prejudice and damage to property
1 530 000
with the exception of the following
Damage to entrusted goods 76 300
Thef 30 500
Non-consequential moral prejudice 305 000
2. After delivery of the products :
For all damage, combined single limit 1 530 000
without it being possible to exceed for the following damage :
Non-consequential moral prejudice, along with removing
and reinstalling costs 305 000
The fact of placing an order with us leads, on the part of our
customers, to the express acceptance of these limits to liability
and to the abandon of the right to take legal action against
us for higher amounts.
Of course, we remain at the disposal of our customers to take
out, the expenses to be borne by them, additional cover in the
event that they find our cover insufficient.
DISPUTES
In the case of disagreement relating to a delivery or its payment,
the Lyon Commercial Court is the sole competent, whatever
may be the sales conditions and the method of payment chosen,
even in the case of proceedings against the guarantor or more
than one defendant.
SPECIAL CONDITIONS
The special conditions and those that may be indicated in the
documentations, quotes or prices forwarded only modify the
sales conditions on the precise points to which they relate.
The general sales and guarantee conditions of our company
are those accepted by the Fdration des Industries
Mcaniques et Transformatrices de Mtaux (Federation of
Mechanical Industries and Metal Transformers), on condition
that they are not contrary to what precedes.
The FIM professional business conditions are registered in the
Commercial Court in Paris under N 2005048625.

Potrebbero piacerti anche