Sei sulla pagina 1di 25

1.What will you do while Soot Blowing?

MANDATORY

Raise the boiler firing rate


Lower the boiler firing rate
Do nothing

ok

2.Steam at 45 t/hr, 60 bar, 510 C. What can be the configuration of astern turbine?

One Curtis of 4 row


2 curtis of 2 row each
6 rows
10 rows

ok

3.For astern running, direction of turbine is reversed by- MANDATORY QUESTION

Admitting steam to a separate turbine connected to same shaft of one of the ahead
turbine

4.During maneuvering , how is condenser vacuum kept low?

Throttling one or more air ejector valve to reduce air ejector steam
Allowing air from glands
Cooling water output

ok

5.During maneuvering , Y is condenser vacuum kept low?

To Prevent distortion of rotor

ok

6.During Preheating ,vacuum is kept minimum why?

To Prevent distortion of rotor

ok

7.Why is vacuum kept high in condenser (MCQ- MORE THAN ONE)

Steam condenses at lower temperature


Steam flow is directed towards condenser
Max heat is utilised
Steam entering condenser hits condensate at bottom readily

It is apparent that the greater the vacuum obtained, the lower will be the temperature of the
steam. The lower the temperature of the steam in the condenser, the more heat we have
available for conversion into mechanical energy in the engines.
After the steam leaves the exhaust section of the turbine, it enters a condenser, where it is
cooled to its liquid state. The process of condensing the steam creates a vacuum, which then
brings in more steam from the turbine

8.Why is Vacuum condenser used?

MANDATORY QUESTION

preventing steam from becoming liquid at the end of turbine


easy air and non condensable gases removal
High Efficiency
Ease of Flow

ok

9.If steam pressure is reduced at inlet of heat exchanger then- MANDATORY QUESTION

Steam temp increases


Steam temp reduces
Steam temp remains same

5 What effect does lowering the steam pressure have?


a) The steam temperature rises

b) It has no effect on the temperature but increases the latent heat

c) The steam temperature falls

d) The total heat in steam increases

ok

10.If a h/e stops working what does that signify?

Steam inlet pr is low


Steam inlet pr is equal to or less than steam outlet pressure.

What is the prime cause of stall in heat exchangers?


a) Not enough steam pressure upstream of the control valve

b) The heat exchanger pressure is equal to or less than the backpressure

c) The heat exchanger is undersized

d) The condensate discharges to atmosphere

@ spirax sarco Stall is the reduction or the cessation of condensate flow from the heat exchanger,
and occurs when the pressure in the heat exchanger is equal to, or less than, the total backpressure
imposed on the steam trap.
11.For same inlet pressure of steam, steam flow rate reduces for bigger heat exchanger becauseMANDATORY QUESTION

More surface area for heat exchange


Steam pressure is less and so enthalpy of evaporation is more
V/v inlet is small

Evap. temp. Low

3 For the same heat load on two heat exchangers, why is the mass flowrate of steam
always less in the exchanger with greater heating surface?
a) Because the control valve is smaller

b) The steam pressure is less and so the enthalpy of evaporation is more

c) Because there is more heating area in the oversized exchanger

d) The steam pressure is less and so the steam will be drier

12.What happens to steam pipeline size after pressure reducing valve

Reduces since steam volume is less at lesser pressure


Increases since steam volume is more at lesser pressure
Remains same

MANDATORY QUESTION

ok

6 The steam pipe after a pressure reducing valve is likely to be:


a) Smaller than the upstream pipe because of the smaller volume of low pressure
steam.

b) The same size as the connection to the plant.


c) Larger than the upstream pipe because the volume of the low pressure steam is
greater.
d) The same size as the upstream pipe because the flowrate through each pipe is the
same.

13.Where do u take bleed steam from? (MTOA)

HP Turbine + LP Turbine
After LP
Crossover Pipe
??????

ok

14.Boiler efficiency is determined by NON MANDATORY

Fuel injected and shaft power


Heat input and power
Steam pressure .......
Steam flow n heat input

ok

15.In BCC system which has feedback from steam pressure, feed forward is provided from

Dump steam
Condensate temp
Steam flow rate

ok

16.In single element feed control system if value of steam flow increases, then feed water flow
MANDATORY

Increases
No change
Decreases

ok

17.Shrink and swell compensation?

feed fwd
feed back
feed fwd and feed back
cannot be compensated

ok

18. Preheating of turbine is done by

Gland steam
condenser
Aux stop valve
Main ahead stop valve

19.Preheating of steam turbine is done slow and prolonged to- (MCQmore than one)

Allow uniform heating of turbine casing


Maintain gap between moving and fixed blades
Reduce differential temperature within casing
Reduce the gap between moving and fixed blades.

20.Why do we open steam v/v slowly? (MCQmore than one) MANDATORY

prevent water hammer


prevent thermal shock
drain condensate
see whether any leaks

doubt

21.More reliable method of testing Steam trap

Sight glass
Gauge glass
Temperature sensing device
Integrated steam trap sensor or separate chamber

22.Why is steam trap not checked by temp sensing device

ok
got on net
MANDATORY QUESTION

It is expensive
It is injurious to health
Temp of steam changes with pressure
Temp of steam and water is same

ok
got on net

23.How many pockets in labyrinth seal of HP and LP Turbine

MANDATORY QUESTION

0
2
3
4

24.In gravity type LO system, pressure sensing device is provided to MANDATORY

Ensure enough LO pressure at turbine


Ensure adequate lubrication of turbine
Both A and B
Neither A nor B

25.Advantage of regenerative(there are moving parts) air preheater over recuperative(no moving
parts) air preheater?........

Less bulky
More corrosion resistant
Easier to manufacture
Doesnt allow air temp to rise to an abnormal level

ok

26.Why is air preheater used/WHY IS AIR PREHEATED? MTOA MANDATORY QUEST

For better combustion


Boiler Efficiency improves
To prevent thermal shock to furnace
To prevent corrosion

ok

27.In Reheat cycle boiler,reheat steam after passing through _____ and ______ is taken back to
boiler and reheated before entering subsequent stages of ahead turbine MANDATORY QUESTION

Superheater ,HP turbine


Economizer, Astern Turbine
Superheater, economizer
Superheater, attemperator

ok

28.Why is air heater in uptakes more prone to fire (MCQmore than one) MANDATORY

More oxygen
High temperature
Soot deposit
Proximity to furnace

29.Economizer tube material?

CI gill section
Mild Steel/Low Carbon steel

ok

30.Whre is deaerator in a 4 stage feed heating system

At 1st stage of discharge of condensate pump


At 2nd stage feed heater
At 3rd stage
At 4th stage before entry to boiler

ok

31.Position of Deaerator at top? MANDATORY QUESTION

To provide NPSH required

32.How is air removed from condenser? (MCQmore than one)

by cooling down the steam


by using steam in the air ejector
ok
using water as a motive fluid for air ejector
daltons principal of partial pressure (this option may or may not be correct depending upon
what is written in the question)

33.How does air ejector remove air?

Uses steam
Uses cooling water
Uses condensate
Improves cooling water flow

ok

34.Function of ejector in a condenser is (MTOA) MANDATORY

To allow steam to pass through to eject air


To allow feed water to pass through to eject air
To allow cooling water to cool
To allow cooling water to pass through to eject air

35.What information is provided on safety valve (MCQmore than one

Lifting pressure
Capacity-flow rate
Reseat press
Standard no

ok

1 Which of the following information is not normally included on the safety valve
marking plate?
a) Set pressure

b) Relieving pressure

c) The relevant standard number

d) Information relating to the capacity of the valve


36.Why safety valves are in pair (MCQmore than one) MANDATORY

One is at a higher pressure than the other


One is at a lower pressure than the other
One cant handle all the steam flow
If one fails, other will open

37.When safety vv is overhauled,the end of the spindle is MANDATORY

Rigidly connted to vv lid


is lapped in the recess of the valve seat after grounding the seat by carborundum paste
Ground
Kept detached from vv lid while assembly

38.What type of reduction gear used in turbine? MANDATORY

double helical and double reduction


Single helical

ok

39.What type of reduction used in turbine?

Helical

ok

40. Flexible coupling in turbine is installed between

turbine and pinion

ok

41. If before you take over the watch, you see that there is no water level in the gauge glass,what
will u do?

Inform duty engineer


Secure the fire

ok

42.Purpose of economizer?

To increase Main propulsion plant efficiency


To reduce the size of boiler

ok

5 What is the purpose of an economiser ?


a) To cool boiler exhaust gases to below dew point

b) To reduce the amount of energy required in the production of steam

c) To enable more steam to be produced from a boiler

d) To utilise heat from boiler exhaust gases

43. Sea water is leaking in condenser then? (MCQmore than one)

Chloride content increases


Vacuum falls
Condenser temp increases
Condenser temp decreases

44.What cant be used as IG on LNG Ships?

IG from boiler
Pure Nitrogen from shore

ok

45.Why is steam line occasionally drained before entering the ahead turbine (MCQmore than one)
MANDATORY
To allow steam to come out
Water in steam can damage blades of turbine
There is a possibility of water hammering

ok

46.Where is steam drain from FO tanks lead to

Observation tank

ok

47.Steam line is drained to

Prevent water hammer


Remove dirt in line

ok

48. ESRD Boiler(ESD type with reheat) , reheated tube is protected by.gas damper (fill in the blanks)
MANDATORY
49. How many gauge glasses are required and why at different levels?

2,for compensating rolling-pitchng

50. When load decreases, what happens

MANDATORY QUESTION

Fuel decreases at a rate faster than air

51. When the boiler load is increased air is increased first and then fuel and vice versa. Why?
MANDATORY QUESTION

part of feed fwd control


to avoid incomplete combustion
fast response
for stablity

52.Chloride test-what all is added and what is the color?

N/35 of silver nitrate;reddish brown

53.Why is hydrazine handled properly?

Toxic n carcinogenic

ok

54.What will happen if hydrazine is added to Low Pressure bOiler?

Reduces oxygen
Breaks down to ammonia
Copper Nitrate

55.What is done in high pressure boiler to remove oxygen? MANDATORY

Hydrazine added
Sodium sulphite added
Feed water taken to boiling point in feed heater
All of the above

56. In N/50 H2SO4, strength of conc is

1/50 of normality
50 times normality
50% of normality
None of above

ok

MANDATORY QUESTION

ok

57.What does N mean in N/50?

Normality

ok

58.Purpose of blowdown valve? (MCQmore than one........ not sure about this)

To remove deposits
To empty the boiler
Legal requiremen
Fill up the Boiler

59.Blowdown sequence

ok

Open ship side then boiler side


Open boiler side then ship side

60.HP turbine is entirely impulse-reaction type

ok

MANDATORY QUESTION

True
False

ok

61.Steam Bleeding from HP Turbine increases the turbine speed MANDATORY QUESTION

True
False

62.Manoeuvring can be done for more than 2hrs continuously

True
False

63.Does bleeding steam improve efficiency of plant

Yes
No

64.In Reaction turbine, Pr. Drop takes place in the nozzle and in the blades

True
False

65.Are all the sodium salts soluble?

Yes
No

66. HP Turbine gland is not sufficient for LP turbine gland pocket in low load condition?

True
False

67.What is open feed system?

Where u allow air to enter


Where u dont preheat the water

68.What is closed feed system?

Where u dont allow the air to enter


Where u preheat the water

ok

69.Meaning of cross compounding? Mandatory question

HP n LP connection using a crossover pipe

ok

70.Purpose of attemperator and desuperheater?


71.Disadvantage of regenerative and recuperative air preheater?
Attemperator- maintains the superheat; desuperheater- reduces the temp of superheated steam

72.Flow of cooling water through condenser?

Axial
radial

OK

73.Why is steam passed through a strainer before passing PRV? MTOA MANDATORY
To prevent any impurity
To prevent any insoluble impurity
To prevent water from passing through

Strainer Strainers arrest any dirt

OK

before it is able to pass into the pressure reducing valve

74. In cross compound turbine, set of nozzle at beginning of HP turbine casing is spread over?
NON MANDATORY

An arc of periphery depending on no of sets of nozzles


Entire periphery
Abt 180 deg of peripehery
Abt 270 deg of peripehery

ok

75. Gland steam in LP Turbine is required so that

No air leaks in turbine


NO steam leaks out of turbine
Both
None

76. Air is preheated in (MCQ- more than one) MANDATORY QUESTION

Economizer
Air heater
Boiler Casing
Air register

OK

77. Joint material between turbine is

Chart paper
Reinforced heat and pressure resistant
Reinforced heat resistant
None

Metal to metal contact

78. Gauge glass is blown through for (MTOA)


To ensure cocks are clear
Correct level is shown
To Ensure water level is above heating surface

ok

79. Chemicals are added in boiler

As dissolved in small quantity and added to feed water going to the boiler
As dissolved in small quantity and added to boiler in one shot

80. In safety vv overhaul, the bottom side drain is

Kept open
Kept plugged
Connected to a drain pipe
Connected to a drain pipe and pipe is made clear

81. Low Pressure steam is obtained from (MCQ--- more than one)
Steam reducing vv
Low pressure boiler
Steam to steam generator
PRV
82. 2 Feed vv is placed in series at the inlet of the boiler to

One is a non return vv which will prevent back flow of water in case the pipe ruptures
Both can be used to control the feed flow
ok
Only one is used at a time

83. Cooling water flow through the condenser (MCQmore than one NON MANDATORY

Is just sufficient to take the latent heat away


Is kept as high as possible to cool the condenser
ok
Cannot be adjusted as the capactity of the pump is the same
Is adjusted commensurate with the outlet temp of the cooling water

84. Outlet of the steam trap is partially chocked

Capacity of steam trap will reduce


Increased differential pressure on steam trap

85. Pressure drop in steam distribution pipeline is due to

Frictional loss and heat loss


Pipeline is meant for lesser pressure
Pipeline is meant for higher pressure
Due to distribution

ok

MANDATORY QUESTION

ok

5 Which of the following results in pressure losses in distribution pipework?

a) Sizing the pipes on low pressure instead of high pressure.

b) Frictional resistance within and heat loss from the pipe and fittings.

c) Sizing the pipes on start-up load of the plant.

d) Large steam users.

86. Feed water is preheated to

Less thermal shock while entering furnace


So that bleed steam can be used
So that only latent heat is required from the boiler
All of these

ok

87. Steam entering HP turbine is dry and superheated .Why? (mcqmore than one) MANDATORY

It doesnt contain water which is injurious to blades


It contains more enthalpy than saturated steam
It doesnt condense readily in steam pipeline
It doesnt condense till it reaches the condenser

ok

88. Steam turbine plant efficiency is increased by

Bleeding steam in stages from turbine

ok

89.Protecting material on Economizer tubes is

CI gills

ok

90. During warming up, the vacuum is kept at maximum

True
False

91. Boiler level control is


Feed back with feed forward signal
Feed forward control with feed back signal
Only feed back signal
Only feed forward signal
92. NaOH reacts with : MANDATORY QUESTION
MgCl2
CaSO4
NaCl

ok

ok

ok

Na2SO4
93. A combustion control system-air is always kept more than required during load changes :

To avoid incomplete combustion


For more stable operation
@spirax sarcoTo ensure complete combustion, an
amount of 'excess air' needs to be provided. This has an effect on boiler efficiency.
For quick response
Part of feed forward system

94. Function of a nozzle is :


to convert enthalpy into kinetic
95. gland packing avoids steam leak at LP side and air leak at HP side of turbine?
True
ok
False
96. gland sealing in LP turbine is required why?
no air enters turbine
no steam leaks from turbine
neither of them
both

ok

97. Air is Preheated in boiler . why? (mcqmore than one) MANDATORY QUESTION
To improve combustion
To effectively utilise bleed steam
To improve thermal efficiency
98. Disadvantage of regenerative type to recuperative type is MANDATORY
Heavy and occupies more space
Less efficiency
Easily corroded
ok
Leak through air seal
99. During sea running conditions, direct contact type feed heater normally receives steam from:
(mcqmore than one)
Feed pump exhaust
Bleed steam
ok
Pressure reducing v/v
???????
100. why weir is provided in remote water level indicator
Steam is always there in the steam side
water is always there in the steam side
water is always there in the water side

ok

Steam is always there in the water side


101. Why phosphate is used in boiler?
To reduce chloride
To reduce alkalinity
To precipitate sludge
102. If water level increases in h/e what happens?
Temperature fluctuates and causes corrosion
Increases the pressure of steam
None

ok

ok

2 What effects will waterlogging cause in some heat exchangers?


a) None at all

b) It increases the steam pressure in the heat exchanger

c) It can cause swings in the temperature of the heated fluid and corrode the heat
exchanger?

d) It increases the thermal performance

103. Balancing of turbo feed p/p rotating part means?


a) static balancing of rotor
b) dynamic balancing of rotor
c) hydraulic balancing the pump end
d) all the above
104. Manoevring vacuum low
a) to have more steam
b) control relative expansion in ahead turbine
c) control relative expansion in astern turbine
d) to allow less steam to circulate within turbine

ok

ok

105. Hydrazine can be added in low pressure boiler


True
False
106. Formula of Hydrazine
N2H4
Ques 107 During maintenance what happens to the valve lid edge MANDATORY QUESTION

Its lapped and grinded by carbonised plate

Only grinded
Not removed/ fixed on valve seat
When it is assembled valve lid is put first

Ques 108 Steam trap if exit is restricted what will happen?

Differential pressure will increase


Temp increase
Temp of condensate released reduces
Capacity reduces (depending upon options available, mark C or D)

6 What is the effect of increasing backpressure on a bimetallic trap?


a) It reduces the temperature of the condensate released by the trap

b) It allows the trap to be used on a higher steam pressure

c) It increases the differential pressure across the trap

d) The trap must be the same size as the condensate drain line

4 What is the effect of higher backpressure on a steam trap?


a) None whatsoever

b) It reduces the steam pressure in the heat exchanger

c) It reduces the capacity of a steam trap

d) It increases the differential pressure across the steam trap

Ques109 Steam trap fails to operate in open position , what happen to the equipment before it?

Efficiency increases
Efficiency decreases
The steam trap is lost
The Equipment does not work

What effect does a steam trap have when failed in the open position?
a) It will stop the plant from operating

b) It will loose steam and cost money

c) Plant efficiency is maintained

d) Plant efficiency is increased

Ques 110 what type of steam trap used on board?


Thermodynamic type

ok

Ques 111 Motive fluid for air ejector in condenser?


Lp steam

doubt

Ques 112 when the feed pump is not supplying water to the boiler then,

It stops
It churns in the casing
It recirculates

ok

Ques 113 before taking watch from another watchkeeper you notice that the gauge glass is empty
for the boiler, what do you do?

Blow down the boiler


Increase the feed flow to the boiler
Inform the watchkeeper
Secure the fire

ok

Ques 114 Condensate heating from the cargo tanks goes to the
observation tank

Ques 115 Reaction turbine has both fixed and free moving nozzles?

True
false

ok

Ques 116 Outer gland pocket in steam turbine what it is used for? MANDATORY

Supply
Exhaust of excess steam

Leak off of Gland (reeds pg-178, GJ Roy Pg-48, Taylor pg-60 ---all except Roy say that
steam leaks from one pocket of gland to the other. In the end we are left with leak off.)
Supply and exhaust

There are two pockets in the glands fitted to all the ends of the turbine; the inner
pocket is connected to the gland steam supply and the outer to the exhaust line . The
HP turbine has to further inner pockets due to it having to deal with steam at higher
pressures and hence increased leakage. The innermost pocket simply passes leakage
steam back to the casing a few stages downstream, the next pocket passes the leakage
steam to the HP turbine exhaust.
When the engine is stopped the gland steam make-up supplies the system
requirements. When the engine is in use the flow of steam to the supply pocket of the
inlet end to the HP end reverses and the gland starts to supply the system reducing the
quantity the make-up has to provide. At full power the only gland requiring steam will
be the exhaust end of the LP turbine, the other will be either supplying the system or
supplying themselves sufficiently to not require steam from the system.In this
condition the make-up would be shut and the pressure regulated by the dump opening.

Ques 117 In normal running condition HP gland steam is not sufficient for LP gland. Do we need
external steam?

True
false

Ques 118 what type of turbine is HP turbine?

Impulse reaction
Reaction
Impulse
Rateau

ok

Ques 119 How is the speed of turbo alternator governed?

By governing the main steam valve


By governing the aux steam valve
By governor controlling the set of nozzle
Something about set of nozzles

ok

Ques 120 why is steam drain from fuel oil heating lead to filter tank? (MTOA) MANDATORY
QUESTION
a)
b)
c)
d)

Trap the oil


Filter oil and insoluble impurity
To watch if any oil coming with the condensate
To cool the condensate in the condenser

ok

Ques 121 Excess steam from hp gland cannot be supplied to the LP gland during normal running of
the vessel?
MANDATORY QUESTION

True
False

ok

Q 122 LP Turbine is purely impulse turbine?

True
False

ok

Q 123 What type of turbine is feed pump?

Impulse
Impulse reaction

ok

Q 124 Material of air heater for low temp. Corrosion? MANDATORY QUESTION

CI Grills
MS fins
Glass or Enamel coating
Electroplating of tin

ok

Q 125 Low vacuum during warming up period so that steam flows slowly

True
False

ok

Q 126 What happens when bearing runs out of turbine?

Severly damaged
Flow of steam automatically stops
Layers of white metal comes out (Reeds pg-142, Taylor pg-65.bearing damaged and being soft comes
out.. contact of rotor with bronze sleeve and this alerts operator but no excessive vibration caused as offset due
to bearing clearance already accounted for during axial alignment of rotor )

Q 127 Markings on steam safety vv

Set pressure
Relieving pressure
Capacity/flow rate

Std. no.

Q 128 How does feed water control system regulate the feed inlet and compensate for large
fluctuations of shrink n swell

MANDATORY QUESTION

feed fwd
feed back
feed fwd and feed back
cannot be compensated

ok

Q 129 Advantage of Rotary cup burner MANDATORY

High tdr
Less maintenance
Cheaper
Less complex

Q 130 Hydrazine can be used in all boilers

True
False

ok

Q 131 How is the content of chloride tested in boiler . MANDATORY QUESTION

Titration by H2SO4
Titration by silver nitrate
By adding drops of silver nitrate

ok

Q 132 If HP Turbine breaks then what arrangement kept on continuing to reach the port?

Desuperheated steam sent to the l.p turbine, flexible coupling removed


Nozzle attached to flange on LP And steam supplied to it.

ok

Q 133 During overhaul of high lift safety valve how is the spindle attached to valve lid

Rigidly so as to allow no movement.

ok

By a pin so that there is some movement between them. Found in safety valve survey(Loose
pin is provided to secure valve lid and allow thermal expansion.)

Q 134 Why boiler gauge glass is used in pair ? (MTOA)


a)
b)
c)
d)

Legal requirement
To compare readings of the two
One show different viewing angle from other./
Only one is used at a time

Q 135 What is inner pocket of gland used for MANDATORY

gauge glass cover d different area

Exhaust
Makeup
Makeup and Exhaust of excess steam
Leak off of steam

Q 136 During sea runnin g conditions, direct contact type feed heater normally receives steam from
(MTOA)
a)
b)
c)
d)

Feed pump exhaust


PRV
Bleed steam
Something ?????

ok

Q 137 why gauge glass blown peroidcaly?


a)to check level
b)visible range

ok

c)1 is standyby
d)to clear cocks.

Q 138 To prevent stm leak and air leak from/to turbines,they r sealed packed.
a)true
b)false.

Q 139 bleed stm used fora)heat fo


b)heat feed water
c)stm to stm generator
d)use in evaporating plant for heating.

Q 140 Hardest salt


MgSO4
CaSO4
CaCO3

ok

Q 141 Direct Contact Feed Water comes in direct contact with


1 Chemicals
2 Steam
3 air
4 O2
Q 142 Vac condensor P low
1 condenstae level increases
2 air ejector not working
3 air leak
4 cooling water througput decrease
Q 143 how is condensor Pressure kept low
1 By throttling
2 allowing air via valve from valve connected onto the shell
3 cooling water output
4 via glands on turbine
Q 144 what if steam trap fails open
1. its expensive and steam lost
2. eff decreases
3. eff increases
Q 145 Function of outer pocket
a exhaust of excess steam
b supply and exhaust
c supply
Q 146 Function of inner pocket
a exhaust of excess steam
b supply and exhaust of excess steam
c supply
Open feed system
In the feed water tank we cool deed water reducing the vapour loss
Feed water tank is used for heating feed water
Q 147 shrink and swell compensation

feed back only


feed fwd
feed back control with feed fwd signal

Q 148 feed pump turbine type

ok

impulse
curtis
velcoity compounded
impulse reaction

Q 149 How blades are secured

It will not come out by centrifugal force


They dont touch each other
It will not come out by centrifugal force
All of the above

Q150 Something related to scum blowdown (wording is quite clear)


Q 151 Turbine heating should be in what drn

Uniform
Fwd
Aft

Q 152 If LO pump of turbine fails then what happens

Maneuvering vv closes instantly and alarm is actuated


Maneuvering vv closes gradually after alarm is actuated

Q 153 How is lp steam obtained onboard MTOA

Using a steam to steam generator

Bleed steam
Lp boiler

PRV

Q154 Speed of feed pump always remains constant

True
Flase

Q155 Enthalpy of ecaporation of water

540 Kcal/Kg

2 Which of the following is the most reliable steam trap tester?


a) A sight glass
b) An ultrasonic listening device
c) A temperature monitoring device
d) An integrated steam trap sensor or separate chamber

3 What are the operating principles of an integrated trap sensing system?


a) Ultrasound detection
b) Conductivity and temperature for leaks and blockages respectively
c) Temperature sensing only
d) Pressure sensing

4 Why is it not feasible to rely on temperature sensing for testing steam leaks?
a) Because it is too difficult
b) Temperature sensing devices cost too much

c) Because steam and condensate can co-exist at the same temperature


d) Because saturation temperature varies with steam pressure

5 What are the most convenient steam trap connections to consider for maintenance
purposes?
a) Screwed connections
b) Flanged connections
c) Socket weld connections
d) Universal swivel connections

6 Which of the following statements is true?


a) Ultrasonic trap testers cannot differentiate live steam and flash steam
b) A Spiratec hand held unit cannot indicate a failed closed steam trap
c) Sight glasses cannot differentiate between live steam and flash steam
d) All of the above

Potrebbero piacerti anche