Sei sulla pagina 1di 328

KCI

Contents
An Introduction to Kerman & Kavian Cable Industries (KCI)

Rated Voltage 150/250 (300) V


Instrument Cables according to IEC 60092-376
IEC 60092-376 ; Cable Construction Requirements
Low Smoke , Halogen free Type :

RE-2X(St)Y

RE-2X(St)H

Page : 13

RE-YCY

RE-2XCH

Page : 35

RE-2X(St)YQY

RE-2X(St)HQH

Page : 57

RE-2X(St)YQY Fire Resistant

RE-2X(St)HQHFire Resistant

Page : 79

Rated Voltage 500 V


Instrument Cables according to EN 50288-7
IEC EN 50288-7 ; Cable Construction Requirements
Low Smoke , Halogen free Type :

RE-Y(St)Y

RE-2X(St)H

Page : 107

RE-2X(St)YFire Resistant

RE-2X(St)HFire Resistant

Page : 129

RE-Y(St)YRY

RE-2X(St)HRH

Page : 151

RE-Y(St)YRY , ..iMFY

RE-2X(St)HRH , ..iMFH

Page : 173

RE-2X(St)YRYFire Resistant

RE-2X(St)HRHFire Resistant

Page : 183

RE-Y(St)YBY

RE-2X(St)HBH

Page : 205

RE-2X(St)YBYFire Resistant

RE-2X(St)HBHFire Resistant

Page : 227

RE-Y(St)YKYRY

RE-2X(St)HKHRH

Page : 249

RE-2X(St)YKYRYFire Resistant

RE-2X(St)HKHRHFire Resistant

Page : 271

RE-2X(St)(L)2Y4YRY

RE-2X(St)(L)2Y4YRH

Page : 293

Appendixes
Cable protection against noise & Screen selection

Page : 314

KERMAN CABLE INDUSTRIES (KCI)

KCI

Kerman & Kavian Cable Industries ( KCI )

KERMAN CABLE INDUSTRIES (KCI) was established in 1984 by co-operation of a team of experts in
industrial estate no.1 of Kerman. In the first phase, KCI had 5000 m2 production area in the land having 20000
m2 for manufacturing several types of cables.
In the second phase, KCI increased the production area to 20000 m2 in the land having area of 60000 m2.
KCI is active in the field of cable production with modern European machinery and with 400 personnel. The
nominal production capacity of the factory is 13600 metric tons of cable products per year.

Instrument Cables

As there are considerable sources of cables main raw materials


(such as copper, pvc, steel, lead,) in IRAN and in the other side
there are huge requirements of wire and cable in IRAN , KERMAN
CABLE INDUSTRIES (KCI) was established by a team of experts
in technical, research and quality control matters .
KCI have modern European machinery and well equipped
laboratories. Manufacturing coaxial cables for TV, CATV, Electronic
industry and data communication and computer networks,
military purposes, mobile and telecommunication centers was the
outstanding point of KCIs innovative activities.
The development of manufacturing lines have been continued by
production of telephone , switchboard cables for telecommunication
, flexible and shielded control cables , instrument cables , power low
voltage cables , submersible pump wires , wires for automobiles
, LAN cable , railway signalling cables , according to special
requirements of corresponding projects up to now .
Most types of mentioned products have been manufactured for the
first time in IRAN which were qualified according to international
test methods and complied with all related projects requirements.
KCI has cooperated with many national and international projects
such as power stations and substations, petrochemical plants, oil and
gas refineries, cement factories, railway, in supply of different
types of required cables.
In addition to continuous innovations, the management has specially emphasized on the quality of products
and services. KCI has certificate of ISO 9001-2000 quality system, national standard and special approvals
from international laboratories such as Warrington fire(in England). Also KCIs QC laboratory has granted
as accredited laboratory of institute standard of IRAN and can test cables on behalf of them. KCI is a well
known company in top brand of cable manufacturers in IRAN and majority of companies active in different
branches of industries have KCI in their approved vendor lists. Recently KCI received merit award from
OIEC Company that was active in phase 9 & 10 of south pars gas field development project, because of on
time delivery and high quality of the cables to that site. Considering above matters and daily needs of our
industries to cable products, KCI has continuous development plans to comply the newest requirements of
those projects.

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KAVIAN CABLE INDUSTRIES (KCI)

KCI
Kerman & Kavian Cable Industries ( KCI )

In order to accomplish main expansion phase of Kerman Cable Industries and by having the background of
30 years experiment in cable industry, KAVIAN CABLE INDUSTRIES(KCI) was established in 1996 in
KAVEH industrial estate (near to SAVEH city). KCI has 17000 m2 of production area in the land having area
of 90000 m2. KCI now is active in the field of cable production with modern European machinery and with
100 personnel. The nominal production capacity of the factory is 17000 metric tons of cable products per year.
As there are considerable sources of cables main raw materials
(such as copper, pvc, steel, lead,) in IRAN and in the other side
there are huge requirements of wire and cable in IRAN , KAVIAN
CABLE INDUSTRIES (KCI) was established by a team of experts
in technical, research and quality control matters .

Instrument Cables

KCI have modern European machinery and well equipped


laboratories. Also in order to accomplish main expansion phase
of Kerman cable factory that new machinery and technology in
new area seemed to be necessary. So management of the company
decided to establish new factory in order to fulfill major part of each
projects required cables.
The new brand of products was telephone cables up to 2400 pairs,
power cable up to 630 mm2 with copper and aluminium conductor
, lead sheathed cables for refineries and similar projects , aerial
power cables , medium voltage cables up to 30kV and being single
or multi core , that all of mentioned cables could be armoured by
steel/aluminium wires or tapes.
All of mentioned cable types have been designed according to
international updated standards which were qualified in tests and
complied with all related projects requirements.
KCI has cooperated with many national and international projects
such as power stations and substations, petrochemical plants, oil and
gas refineries, cement factories, railway, in supply of several types
of required cables.
In addition to continuous innovations, the management has specially
emphasized on the quality of products and services.
KCI special approvals from international laboratories such as
KEMA (in Netherlands) and Warrington fire (in England).

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Kerman & Kavian Cable Industries ( KCI )

KCI

Cables for control and instrumentation circuits 150/250 V (300 V)


According to of IEC 60092-376 (2003)
Electrical installations in ships - Part 376:

KCI

Kerman & Kavian Cable Industries ( KCI )

A Summary of IEC 60092-376 (2003)


Electrical installations in ships - Part 376:
Cables for control and instrumentation circuits 150/250 V (300 V)

Scope and object :


This part of IEC 60092 is applicable to screened and unscreened cables for control and instrumentation
circuits on ships and offshore units.
The cables have extruded solid insulation with a voltage rating of 150/250V (300V) and are intended
for fixed installations.
Rated voltage :
The standard rated voltage Uo/U (Um) is as follows:
UO/U (UM) = 150 V/250 V (300 V) a.c.
In the voltage designation of cables ;
UO : is the rated power-frequency voltage between the conductor and the earth or metallic covering
for which the cable is designed;
U : is the rated power-frequency voltage between conductors for which the cable is designed.
UM : is the maximum value of the highest system voltage for which the equipment may be used.
A d.c. voltage up to a maximum of 1.5 times the a.c. voltage may be used, provided that the voltage to
earth does not exceed 250 V.

1 ) Conductors :
The material, metal coating, separator, class and form of the conductors shall be in accordance with IEC
60092-350 and shall be circular Class 2 or Class 5 constructions of cross-sectional area
0.50 mm2, 0.75 mm2, 1.0 mm2, 1.5 mm2 or 2.5 mm2.

Instrument Cables

Note : The preferred conductor sizes are 0.75 mm2 and 1.5 mm2.

Class 2 Stranding
Nominal cross
section of
conductors (mm2)

Class 5 Stranding

DC resistance of (conductors)
plain copper

tinned copper

plain copper

tinned copper

Ohm/kM at 20C
8

0.5

40.4

41.6

41.4

42.5

0.75

26

26.3

27.6

28.3

1.0

19.2

19.3

20.7

21.2

1.5

12.8

12.9

14.1

14.5

2.5

7.86

8.02

8.47

8.71

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

Kerman & Kavian Cable Industries ( KCI )

KCI

2 ) Insulation system
The insulation system shall consist of either;
2-1 ) one of the insulating compounds indicated in following Table

2-2) a combination of one or more layers of inorganic tape(s) and a layer of one of the insulating
compounds indicated in following Table (example Mica-Glass Tape + XLPE )

2-1) An Insulated Conductor

2-2) A Conductor Insulated by


by Mica-glass and an extruded Insulation
Used as insulation of Fire-Resistance Cables

PVC/A

EPR

XLPE

HEPR

HF 85

S 95

mm2

mm

mm

mm

mm

mm

mm

0.5

0.6

0.6

0.4

0.4

0.6

0.6

0.75
1.0
1.5
2.5

0.6
0.6
0.7
0.7

0.6
0.6
0.7
0.7

0.5
0.5
0.6
0.6

0.5
0.5
0.6
0.6

0.6
0.6
0.7
0.7

0.6
0.6
0.7
0.7

Instrument Cables

Nominal
cross
section of
conductors

PVC : Poly vinyl chloride

XLPE : Cross-linked Polyethylene


9

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

KCI

3 ) Cabling

Kerman & Kavian Cable Industries ( KCI )

3-1 ) Core assembly (multicore cables)


The individual cores shall be twisted together in concentric layers.
3-2 ) Forming pair, triple or quad units ;
Cores shall be twisted together with either a left hand or right hand lay to form a pair, triple or quad unit.
The lay length of the cores individually or collectively screened shall not exceed 120 mm for sizes below
1.5 mm2 and 150 mm for sizes 1.5 mm2 and above.

Core (Unit)

Pair (Unit)

Triple (Unit)

3-3 ) Typical colour code for single unit cables


Unit element

Wire a

Wire b

Wire c

Wire d

Pair unit
Triple unit
Quad unit

Black
Black
Black

White
White
White

Red
Red

Blue

3-4 ) Number of cores


It is recommended that the number of cores shall be selected from one of the following:
2, 4, 7, 12, 19, 27, 37.
3-5 ) Number of pair, triple or quad units
It is recommended that the number of pair units shall be selected from one of the following:
1, 3, 7, 12, 19, 27, 37.

Instrument Cables

4 ) Electrostatic screen

10

4-1 ) Individually taped screened pair, triple or quad constructions


When an individual taped screened pair, triple or quad construction is required, each pair, triple or quad
shall have a laminated electrostatic screening tape applied with the metallic side in electrical contact with
a drain wire. The nominal overlap shall not be less than 25 %.
The laminated electrostatic screening tape shall be either aluminium bonded to polyester having a
minimum thickness of aluminium of 0.008 mm and a minimum thickness of polyester of 0.010 mm, or
copper bonded to polyester having a minimum thickness of copper of 0.018 mm and a minimum thickness
of polyester of 0.023 mm.
The drain wire shall be composed of a number of strands of tinned annealed copper wires in the case of
aluminium laminate tape and either plain or tinned annealed copper wires in the case of copper laminate
tape.The drain wire shall have a maximum resistance in accordance with following Table .

Pair (Unit) Individually Screened


in Metallic Foil (PiMF)

Triple (Unit) Individually Screened


in Metallic Foil (TiMF)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

Nominal cross section


of conductors

Maximum drain wire


resistance

mm2

Ohm/km

0.5

61.2

0.75

42.5

1.0

28.3

1.5

28.3

2.5

21.2

Kerman & Kavian Cable Industries ( KCI )

4-2 ) Individually braided screened pair, triple or quad constructions


When an individual braided screened pair, triple or quad construction is required, each pair, triple or quad
shall have a non-hygroscopic separator tape applied over the cores and under the braid.
The nominal overlap shall not be less than 25 %.
The braid shall be either plain or metal coated copper wires; the minimum diameter of the braid wire shall
be: When required, to aid termination, a drain wire may be applied under and in direct contact with the braid
screen.The drain wire shall be composed of a number of strands of tinned or plain annealed copper wires. The
drain wire shall have a maximum resistance in accordance with following Table .

Braid (Screen)

Static Tape (Screen)

4-3 ) Collectively screened constructions


Similar to 4-1) and 4-2) ; both taped and braided screens type is permitted .

5 ) Metal braid armour


In this standard the braid wires are either:
zinc coated (galvanised) steel , or
copper (plain or tinned),

Zinc coated (galvanized)


Steel wires Braid

Plain Copper wires


Braid

Tinned Plain Copper


wires Braid

6 ) Sheath(s)
Could be one of following materials ; PVC , PE , Halogen Free .
The sheath shall be coloured black or grey unless otherwise specified.
Note : The sheath may be of other colours, thereby providing a visual difference to
that of LV and MV Power cables.

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Note : In the case of plain or tinned copper wire braids, these may also provide the function of an electrostatic
collective screen providing they are terminated to earth.

11

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)Y

IEC 60092-376

RE-2X(St)Y

Multi-Core

RE-2X(St)Y

Multi-Pair

RE-2X(St)Y

Multi-Triple

RE-2X(St)Y

PiMF

RE-2X(St)Y

TiMF

150/250 V (300 V)

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)H
RE-2X(St)H Multi-Core
RE-2X(St)H Multi-Pair
RE-2X(St)H Multi-Triple
RE-2X(St)H PiMF
RE-2X(St)H TiMF

KCI

RE-2X(St)Y
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+90 oC

Instrument Cables

14

XLPE
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


2x0.5

0.4

1.0

5.7

48

1000

3x0.5

0.4

1.0

6.0

56

1000

4x0.5

0.4

1.0

6.4

64

1000

5x0.5

0.4

1.0

6.9

73

1000

6x0.5

0.4

1.0

7.4

82

1000

7x0.5

0.4

1.0

7.4

88

1000

8x0.5

0.4

1.1

8.6

103

1000

10x0.5

0.4

1.1

9.3

119

1000

12x0.5

0.4

1.1

9.6

133

1000

16x0.5

0.4

1.1

10.5

163

1000

20x0.5

0.4

1.2

11.7

199

1000

24x0.5

0.4

1.2

12.9

231

1000

30x0.5

0.4

1.3

13.8

278

1000

2x0.75

0.5

1.0

6.5

59

1000

3x0.75

0.5

1.0

6.8

70

1000

4x0.75

0.5

1.0

7.4

83

1000

5x0.75

0.5

1.0

8.0

95

1000

6x0.75

0.5

1.1

8.8

112

1000

7x0.75

0.5

1.1

8.8

121

1000

8x0.75

0.5

1.1

10.1

138

1000

10x0.75

0.5

1.2

11.1

166

1000

12x0.75

0.5

1.2

11.5

187

1000

16x0.75

0.5

1.2

12.6

232

1000

20x0.75

0.5

1.3

14.1

284

1000

24x0.75

0.5

1.3

15.5

331

1000

30x0.75

0.5

1.4

16.6

401

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

15

KCI

RE-2X(St)Y

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.5

1.0

6.9

61

1000

3x1

0.5

1.0

7.2

75

1000

4x1

0.5

1.0

7.8

90

1000

5x1

0.5

1.1

8.7

109

1000

6x1

0.5

1.1

9.4

125

1000

7x1

0.5

1.1

9.4

138

1000

8x1

0.5

1.1

10.7

157

1000

10x1

0.5

1.2

11.8

192

1000

12x1

0.5

1.2

12.2

219

1000

16x1

0.5

1.2

13.5

275

1000

20x1

0.5

1.3

15.1

339

1000

24x1

0.5

1.3

16.6

398

1000

30x1

0.5

1.4

17.8

485

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

16

2x1.5

0.6

1.0

7.9

78

1000

3x1.5

0.6

1.1

8.5

103

1000

4x1.5

0.6

1.1

9.2

125

1000

5x1.5

0.6

1.1

10.0

148

1000

6x1.5

0.6

1.1

10.9

171

1000

7x1.5

0.6

1.1

10.9

189

1000

8x1.5

0.6

1.2

12.7

223

1000

10x1.5

0.6

1.3

14.0

272

1000

12x1.5

0.6

1.3

14.5

312

1000

16x1.5

0.6

1.3

16.0

395

1000

20x1.5

0.6

1.4

18.0

488

1000

24x1.5

0.6

1.5

20.0

584

1000

30x1.5

0.6

1.5

21.2

702

1000

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.6

1.1

8.9

108

1000

3x2.5

0.6

1.1

9.4

138

1000

4x2.5

0.6

1.1

10.3

171

1000

5x2.5

0.6

1.2

11.4

209

1000

6x2.5

0.6

1.2

12.3

242

1000

7x2.5

0.6

1.2

12.3

270

1000

8x2.5

0.6

1.3

14.4

316

1000

10x2.5

0.6

1.3

15.7

380

1000

12x2.5

0.6

1.3

16.2

438

1000

16x2.5

0.6

1.4

18.2

569

1000

20x2.5

0.6

1.5

20.4

703

1000

24x2.5

0.6

1.6

22.7

840

1000

30x2.5

0.6

1.6

24.1

1017

1000

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

17

KCI

RE-2X(St)Y
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria

18

Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.4

1.0

5.7

49

1000

2x2x0.5

0.4

1.0

7.9

72

1000

3x2x0.5

0.4

1.1

8.5

91

1000

4x2x0.5

0.4

1.1

9.2

108

1000

5x2x0.5

0.4

1.1

10.0

125

1000

6x2x0.5

0.4

1.1

10.9

142

1000

7x2x0.5

0.4

1.1

10.9

155

1000

10x2x0.5

0.4

1.3

14.0

221

1000

12x2x0.5

0.4

1.3

14.5

249

1000

16x2x0.5

0.4

1.3

16.0

309

1000

20x2x0.5

0.4

1.4

17.9

379

1000

24x2x0.5

0.4

1.5

20.0

451

1000

30x2x0.5

0.4

1.5

21.2

535

1000

1x2x0.75

0.5

1.0

6.5

60

1000

2x2x0.75

0.5

1.1

9.4

97

1000

3x2x0.75

0.5

1.1

10.0

119

1000

4x2x0.75

0.5

1.1

10.9

143

1000

5x2x0.75

0.5

1.2

12.0

174

1000

6x2x0.75

0.5

1.2

13.1

199

1000

7x2x0.75

0.5

1.2

13.1

218

1000

10x2x0.75

0.5

1.4

16.9

312

1000

12x2x0.75

0.5

1.4

17.5

355

1000

16x2x0.75

0.5

1.5

19.6

453

1000

20x2x0.75

0.5

1.5

21.7

547

1000

24x2x0.75

0.5

1.6

24.3

652

1000

30x2x0.75

0.5

1.7

25.9

790

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

19

KCI

RE-2X(St)Y

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.5

1.0

6.9

61

1000

2x2x1

0.5

1.1

10.0

106

1000

3x2x1

0.5

1.1

10.6

134

1000

4x2x1

0.5

1.2

11.8

169

1000

5x2x1

0.5

1.2

12.8

201

1000

6x2x1

0.5

1.2

14.0

232

1000

7x2x1

0.5

1.2

14.0

257

1000

10x2x1

0.5

1.4

18.1

371

1000

12x2x1

0.5

1.4

18.7

424

1000

16x2x1

0.5

1.5

20.9

547

1000

20x2x1

0.5

1.6

23.5

675

1000

24x2x1

0.5

1.7

26.2

806

500

30x2x1

0.5

1.7

27.8

967

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

20

1x2x1.5

0.6

1.0

7.9

79

1000

2x2x1.5

0.6

1.2

11.8

145

1000

3x2x1.5

0.6

1.2

12.6

187

1000

4x2x1.5

0.6

1.2

13.8

232

1000

5x2x1.5

0.6

1.3

15.2

284

1000

6x2x1.5

0.6

1.3

16.6

330

1000

7x2x1.5

0.6

1.3

16.6

368

1000

10x2x1.5

0.6

1.5

21.6

529

1000

12x2x1.5

0.6

1.5

22.3

609

1000

16x2x1.5

0.6

1.6

25.0

789

500

20x2x1.5

0.6

1.7

28.1

974

500

24x2x1.5

0.6

1.9

31.5

1178

500

30x2x1.5

0.6

1.9

33.4

1420

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.6

1.1

8.9

109

1000

2x2x2.5

0.6

1.2

13.2

194

1000

3x2x2.5

0.6

1.3

14.3

262

1000

4x2x2.5

0.6

1.3

15.6

328

1000

5x2x2.5

0.6

1.4

17.3

402

1000

6x2x2.5

0.6

1.4

18.9

469

1000

7x2x2.5

0.6

1.4

18.9

526

1000

10x2x2.5

0.6

1.6

24.5

755

500

12x2x2.5

0.6

1.7

25.6

886

500

16x2x2.5

0.6

1.8

28.6

1149

500

20x2x2.5

0.6

1.9

32.1

1419

500

24x2x2.5

0.6

2.0

35.9

1694

500

30x2x2.5

0.6

2.1

38.2

2072

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

21

KCI

RE-2X(St)Y
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

Instrument Cables

Criteria

22

Conductor cross section

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.4

1.0

6.0

56

1000

2x3x0.5

0.4

1.1

8.8

93

1000

3x3x0.5

0.4

1.1

9.3

115

1000

4x3x0.5

0.4

1.1

10.2

138

1000

5x3x0.5

0.4

1.2

11.3

167

1000

6x3x0.5

0.4

1.2

12.2

192

1000

7x3x0.5

0.4

1.2

12.2

211

1000

10x3x0.5

0.4

1.3

15.6

294

1000

12x3x0.5

0.4

1.3

16.1

335

1000

16x3x0.5

0.4

1.4

18.0

430

1000

20x3x0.5

0.4

1.5

20.2

528

1000

24x3x0.5

0.4

1.6

22.5

630

1000

30x3x0.5

0.4

1.6

23.8

753

1000

1x3x0.75

0.5

1.0

6.8

71

1000

2x3x0.75

0.5

1.1

10.4

122

1000

3x3x0.75

0.5

1.2

11.2

159

1000

4x3x0.75

0.5

1.2

12.2

194

1000

5x3x0.75

0.5

1.2

13.3

230

1000

6x3x0.75

0.5

1.3

14.7

272

1000

7x3x0.75

0.5

1.3

14.7

301

1000

10x3x0.75

0.5

1.4

18.9

422

1000

12x3x0.75

0.5

1.5

19.7

493

1000

16x3x0.75

0.5

1.5

21.8

624

1000

20x3x0.75

0.5

1.6

24.5

769

500

24x3x0.75

0.5

1.7

27.3

918

500

30x3x0.75

0.5

1.8

29.2

1118

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

23

KCI

RE-2X(St)Y

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.5

1.0

7.2

76

1000

2x3x1

0.5

1.1

11.0

136

1000

3x3x1

0.5

1.2

11.9

183

1000

4x3x1

0.5

1.2

13.0

227

1000

5x3x1

0.5

1.3

14.4

278

1000

6x3x1

0.5

1.3

15.7

323

1000

7x3x1

0.5

1.3

15.7

360

1000

10x3x1

0.5

1.5

20.4

518

1000

12x3x1

0.5

1.5

21.1

598

1000

16x3x1

0.5

1.6

23.6

775

1000

20x3x1

0.5

1.7

26.5

957

500

24x3x1

0.5

1.8

29.6

1143

500

30x3x1

0.5

1.8

31.3

1382

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

24

1x3x1.5

0.6

1.0

8.3

100

1000

2x3x1.5

0.6

1.2

13.1

190

1000

3x3x1.5

0.6

1.2

13.9

252

1000

4x3x1.5

0.6

1.3

15.5

323

1000

5x3x1.5

0.6

1.4

17.2

396

1000

6x3x1.5

0.6

1.4

18.7

463

1000

7x3x1.5

0.6

1.4

18.7

520

1000

10x3x1.5

0.6

1.6

24.3

746

1000

12x3x1.5

0.6

1.6

25.2

865

500

16x3x1.5

0.6

1.7

28.2

1125

500

20x3x1.5

0.6

1.9

31.9

1405

500

24x3x1.5

0.6

2.0

35.6

1679

500

30x3x1.5

0.6

2.1

37.9

2053

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.6

1.1

9.4

140

1000

2x3x2.5

0.6

1.3

14.9

267

1000

3x3x2.5

0.6

1.3

15.8

358

1000

4x3x2.5

0.6

1.4

17.6

461

1000

5x3x2.5

0.6

1.4

19.3

557

1000

6x3x2.5

0.6

1.5

21.3

664

1000

7x3x2.5

0.6

1.5

21.3

749

1000

10x3x2.5

0.6

1.7

27.7

1073

500

12x3x2.5

0.6

1.8

28.8

1264

500

16x3x2.5

0.6

1.9

32.3

1646

500

20x3x2.5

0.6

2.0

36.3

2037

500

24x3x2.5

0.6

2.2

40.7

2452

500

30x3x2.5

0.6

2.3

43.3

3007

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

25

KCI

RE-2X(St)Y , PiMF
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria

26

Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.4

1.0

6.0

66

1000

2x2x0.5

0.4

1.1

9.2

113

1000

3x2x0.5

0.4

1.1

9.7

145

1000

4x2x0.5

0.4

1.1

10.6

178

1000

5x2x0.5

0.4

1.2

11.7

216

1000

6x2x0.5

0.4

1.2

12.7

251

1000

7x2x0.5

0.4

1.2

12.7

279

1000

10x2x0.5

0.4

1.3

16.3

391

1000

12x2x0.5

0.4

1.4

17.0

458

1000

16x2x0.5

0.4

1.4

18.8

584

1000

20x2x0.5

0.4

1.5

21.1

720

1000

24x2x0.5

0.4

1.6

23.5

860

1000

30x2x0.5

0.4

1.6

24.9

1040

500

1x2x0.75

0.5

1.0

6.9

78

1000

2x2x0.75

0.5

1.1

10.6

136

1000

3x2x0.75

0.5

1.2

11.5

181

1000

4x2x0.75

0.5

1.2

12.5

222

1000

5x2x0.75

0.5

1.2

13.7

265

1000

6x2x0.75

0.5

1.3

15.1

314

1000

7x2x0.75

0.5

1.3

15.1

350

1000

10x2x0.75

0.5

1.4

19.4

492

1000

12x2x0.75

0.5

1.5

20.2

576

1000

16x2x0.75

0.5

1.6

22.6

745

1000

20x2x0.75

0.5

1.7

25.4

918

500

24x2x0.75

0.5

1.8

28.3

1096

500

30x2x0.75

0.5

1.8

30.0

1323

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

27

KCI

RE-2X(St)Y , PiMF

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.5

1.0

7.2

74

1000

2x2x1

0.5

1.1

11.3

134

1000

3x2x1

0.5

1.2

12.2

179

1000

4x2x1

0.5

1.2

13.3

222

1000

5x2x1

0.5

1.3

14.7

271

1000

6x2x1

0.5

1.3

16.1

316

1000

7x2x1

0.5

1.3

16.1

351

1000

10x2x1

0.5

1.5

20.9

505

1000

12x2x1

0.5

1.5

21.6

582

1000

16x2x1

0.5

1.6

24.1

753

1000

20x2x1

0.5

1.7

27.1

929

500

24x2x1

0.5

1.8

30.2

1110

500

30x2x1

0.5

1.9

32.2

1354

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

28

1x2x1.5

0.6

1.0

8.2

92

1000

2x2x1.5

0.6

1.2

13.2

177

1000

3x2x1.5

0.6

1.3

14.3

238

1000

4x2x1.5

0.6

1.3

15.7

295

1000

5x2x1.5

0.6

1.4

17.3

362

1000

6x2x1.5

0.6

1.4

18.9

422

1000

7x2x1.5

0.6

1.4

18.9

471

1000

10x2x1.5

0.6

1.6

24.6

677

500

12x2x1.5

0.6

1.6

25.5

782

500

16x2x1.5

0.6

1.8

28.7

1026

500

20x2x1.5

0.6

1.9

32.2

1266

500

24x2x1.5

0.6

2.0

36.0

1511

500

30x2x1.5

0.6

2.1

38.3

1843

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.6

1.1

9.3

126

1000

2x2x2.5

0.6

1.3

14.9

240

1000

3x2x2.5

0.6

1.3

15.9

317

1000

4x2x2.5

0.6

1.4

17.7

407

1000

5x2x2.5

0.6

1.4

19.4

490

1000

6x2x2.5

0.6

1.5

21.4

583

1000

7x2x2.5

0.6

1.5

21.4

654

1000

10x2x2.5

0.6

1.7

27.8

938

500

12x2x2.5

0.6

1.8

29.0

1102

500

16x2x2.5

0.6

1.9

32.4

1430

500

20x2x2.5

0.6

2.0

36.4

1767

500

24x2x2.5

0.6

2.2

40.9

2128

500

30x2x2.5

0.6

2.3

43.5

2601

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

29

KCI

RE-2X(St)Y , TiMF
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+90 oC

Instrument Cables

30

Conductor cross section

XLPE
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.4

1.0

6.3

74

1000

2x3x0.5

0.4

1.1

10.1

131

1000

3x3x0.5

0.4

1.1

10.7

169

1000

4x3x0.5

0.4

1.2

11.9

215

1000

5x3x0.5

0.4

1.2

12.9

256

1000

6x3x0.5

0.4

1.3

14.2

304

1000

7x3x0.5

0.4

1.3

14.2

339

1000

10x3x0.5

0.4

1.4

18.2

476

1000

12x3x0.5

0.4

1.4

18.8

549

1000

16x3x0.5

0.4

1.5

21.1

712

1000

20x3x0.5

0.4

1.6

23.7

879

1000

24x3x0.5

0.4

1.7

26.4

1050

500

30x3x0.5

0.4

1.7

28.0

1271

500

1x3x0.75

0.5

1.0

7.2

89

1000

2x3x0.75

0.5

1.2

11.9

167

1000

3x3x0.75

0.5

1.2

12.7

217

1000

4x3x0.75

0.5

1.2

13.9

270

1000

5x3x0.75

0.5

1.3

15.4

330

1000

6x3x0.75

0.5

1.4

16.9

392

1000

7x3x0.75

0.5

1.4

16.9

437

1000

10x3x0.75

0.5

1.5

21.8

616

1000

12x3x0.75

0.5

1.6

22.7

722

1000

16x3x0.75

0.5

1.7

25.4

935

500

20x3x0.75

0.5

1.8

28.5

1153

500

24x3x0.75

0.5

1.9

31.8

1377

500

30x3x0.75

0.5

2.0

33.9

1682

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

31

KCI

RE-2X(St)Y , TiMF

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.5

1.0

7.6

88

1000

2x3x1

0.5

1.2

12.7

172

1000

3x3x1

0.5

1.2

13.5

225

1000

4x3x1

0.5

1.3

14.9

288

1000

5x3x1

0.5

1.3

16.3

345

1000

6x3x1

0.5

1.4

18.0

412

1000

7x3x1

0.5

1.4

18.0

460

1000

10x3x1

0.5

1.6

23.4

661

1000

12x3x1

0.5

1.6

24.2

763

1000

16x3x1

0.5

1.7

27.1

990

500

20x3x1

0.5

1.8

30.4

1223

500

24x3x1

0.5

1.9

34.0

1461

500

30x3x1

0.5

2.0

36.2

1786

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

32

1x3x1.5

0.6

1.1

8.9

118

1000

2x3x1.5

0.6

1.3

14.9

231

1000

3x3x1.5

0.6

1.3

15.8

305

1000

4x3x1.5

0.6

1.4

17.6

391

1000

5x3x1.5

0.6

1.4

19.3

471

1000

6x3x1.5

0.6

1.5

21.3

561

1000

7x3x1.5

0.6

1.5

21.3

629

1000

10x3x1.5

0.6

1.7

27.7

903

500

12x3x1.5

0.6

1.8

28.8

1060

500

16x3x1.5

0.6

1.9

32.3

1375

500

20x3x1.5

0.6

2.0

36.3

1699

500

24x3x1.5

0.6

2.2

40.7

2047

500

30x3x1.5

0.6

2.3

43.3

2502

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.6

1.1

9.8

157

1000

2x3x2.5

0.6

1.3

16.6

308

1000

3x3x2.5

0.6

1.4

17.9

423

1000

4x3x2.5

0.6

1.4

19.7

535

1000

5x3x2.5

0.6

1.5

21.8

658

1000

6x3x2.5

0.6

1.6

24.0

785

1000

7x3x2.5

0.6

1.6

24.0

884

1000

10x3x2.5

0.6

1.9

31.5

1281

500

12x3x2.5

0.6

1.9

32.6

1491

500

16x3x2.5

0.6

2.0

36.5

1941

500

20x3x2.5

0.6

2.2

41.2

2420

500

24x3x2.5

0.6

2.4

46.2

2911

500

30x3x2.5

0.6

2.5

49.2

3565

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

33

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-YCY

IEC 60092-376

150/250 V (300 V)

RE-YCY Multi-Core
RE-YCY Multi-Pair
RE-YCY Multi-Triple
RE-YCY PiMF
RE-YCY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2XCH
RE-2XCH Multi-Core
RE-2XCH Multi-Pair
RE-2XCH Multi-Triple
RE-2XCH PiMF
RE-2XCH TiMF

KCI

RE-YCY
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+70 oC

Instrument Cables

36

PVC
Core (Multi-Core Cable)
Braid of Copper Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


2x0.5

0.6

1.0

7.0

65

1000

3x0.5

0.6

1.0

7.4

76

1000

4x0.5

0.6

1.0

7.9

91

1000

5x0.5

0.6

1.1

8.7

110

1000

6x0.5

0.6

1.1

9.3

123

1000

7x0.5

0.6

1.1

9.3

131

1000

8x0.5

0.6

1.1

10.6

151

1000

10x0.5

0.6

1.2

11.6

178

1000

12x0.5

0.6

1.2

12.0

198

1000

16x0.5

0.6

1.2

13.3

266

1000

20x0.5

0.6

1.3

14.8

324

1000

24x0.5

0.6

1.4

16.4

377

1000

30x0.5

0.6

1.4

17.3

443

1000

2x0.75

0.6

1.0

7.4

73

1000

3x0.75

0.6

1.0

7.8

91

1000

4x0.75

0.6

1.1

8.6

109

1000

5x0.75

0.6

1.1

9.3

129

1000

6x0.75

0.6

1.1

9.9

148

1000

7x0.75

0.6

1.1

9.9

160

1000

8x0.75

0.6

1.2

11.5

185

1000

10x0.75

0.6

1.2

12.7

233

1000

12x0.75

0.6

1.2

13.1

266

1000

16x0.75

0.6

1.3

14.5

328

1000

20x0.75

0.6

1.3

16.0

392

1000

24x0.75

0.6

1.4

17.7

466

1000

30x0.75

0.6

1.4

18.9

577

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

37

KCI

RE-YCY

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

1.0

7.8

85

1000

3x1

0.6

1.0

8.2

102

1000

4x1

0.6

1.1

9.0

128

1000

5x1

0.6

1.1

9.7

146

1000

6x1

0.6

1.1

10.5

169

1000

7x1

0.6

1.1

10.5

184

1000

8x1

0.6

1.2

12.4

231

1000

10x1

0.6

1.2

13.4

274

1000

12x1

0.6

1.2

13.8

307

1000

16x1

0.6

1.3

15.3

389

1000

20x1

0.6

1.4

17.1

474

1000

24x1

0.6

1.4

19.0

580

1000

30x1

0.6

1.5

20.2

686

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

38

2x1.5

0.7

1.1

9.0

112

1000

3x1.5

0.7

1.1

9.5

137

1000

4x1.5

0.7

1.1

10.3

167

1000

5x1.5

0.7

1.2

11.3

198

1000

6x1.5

0.7

1.2

12.4

245

1000

7x1.5

0.7

1.2

12.4

267

1000

8x1.5

0.7

1.3

14.4

314

1000

10x1.5

0.7

1.3

15.6

373

1000

12x1.5

0.7

1.3

16.1

420

1000

16x1.5

0.7

1.4

17.9

535

1000

20x1.5

0.7

1.5

20.2

681

1000

24x1.5

0.7

1.6

22.4

809

1000

30x1.5

0.7

1.6

23.6

953

1000

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

1.1

9.8

141

1000

3x2.5

0.7

1.1

10.4

176

1000

4x2.5

0.7

1.2

11.5

218

1000

5x2.5

0.7

1.2

12.7

275

1000

6x2.5

0.7

1.2

13.7

320

1000

7x2.5

0.7

1.2

13.7

352

1000

8x2.5

0.7

1.3

15.9

412

1000

10x2.5

0.7

1.4

17.5

502

1000

12x2.5

0.7

1.4

18.0

570

1000

16x2.5

0.7

1.5

20.3

755

1000

20x2.5

0.7

1.6

22.6

926

1000

24x2.5

0.7

1.6

24.9

1084

500

30x2.5

0.7

1.7

26.5

1303

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2XCH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

39

KCI

RE-YCY
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+70 oC

Instrument Cables

40

IEC 60708 Full color

Braid of Copper Wires


Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

PVC
Pair (Multi-Pair Cable)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.6

1.0

7.0

66

1000

2x2x0.5

0.6

1.1

9.9

113

1000

3x2x0.5

0.6

1.1

10.5

134

1000

4x2x0.5

0.6

1.2

11.6

162

1000

5x2x0.5

0.6

1.2

12.7

205

1000

6x2x0.5

0.6

1.3

14.0

243

1000

7x2x0.5

0.6

1.3

14.0

261

1000

10x2x0.5

0.6

1.4

17.6

362

1000

12x2x0.5

0.6

1.4

18.2

402

1000

16x2x0.5

0.6

1.5

20.5

531

1000

20x2x0.5

0.6

1.6

22.8

646

1000

24x2x0.5

0.6

1.7

25.3

760

500

30x2x0.5

0.6

1.7

26.7

883

500

1x2x0.75

0.6

1.0

7.4

74

1000

2x2x0.75

0.6

1.1

10.6

129

1000

3x2x0.75

0.6

1.2

11.4

162

1000

4x2x0.75

0.6

1.2

12.6

211

1000

5x2x0.75

0.6

1.2

13.7

249

1000

6x2x0.75

0.6

1.3

15.0

294

1000

7x2x0.75

0.6

1.3

15.0

318

1000

10x2x0.75

0.6

1.4

19.2

467

1000

12x2x0.75

0.6

1.5

20.0

530

1000

16x2x0.75

0.6

1.5

22.1

657

1000

20x2x0.75

0.6

1.6

24.7

795

500

24x2x0.75

0.6

1.7

27.4

944

500

30x2x0.75

0.6

1.8

29.2

1120

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

41

KCI

RE-YCY

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

1.0

7.8

86

1000

2x2x1

0.6

1.1

11.2

145

1000

3x2x1

0.6

1.2

12.3

203

1000

4x2x1

0.6

1.2

13.3

247

1000

5x2x1

0.6

1.3

14.7

298

1000

6x2x1

0.6

1.3

15.9

337

1000

7x2x1

0.6

1.3

15.9

367

1000

10x2x1

0.6

1.5

20.6

548

1000

12x2x1

0.6

1.5

21.3

614

1000

16x2x1

0.6

1.6

23.7

779

1000

20x2x1

0.6

1.7

26.4

946

500

24x2x1

0.6

1.8

29.4

1125

500

30x2x1

0.6

1.8

31.0

1327

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

42

1x2x1.5

0.7

1.1

9.0

113

1000

2x2x1.5

0.7

1.2

13.3

215

1000

3x2x1.5

0.7

1.3

14.2

271

1000

4x2x1.5

0.7

1.3

15.5

332

1000

5x2x1.5

0.7

1.4

17.1

402

1000

6x2x1.5

0.7

1.4

18.6

458

1000

7x2x1.5

0.7

1.4

18.6

503

1000

10x2x1.5

0.7

1.6

24.1

748

1000

12x2x1.5

0.7

1.6

24.9

852

500

16x2x1.5

0.7

1.7

27.7

1086

500

20x2x1.5

0.7

1.9

31.2

1330

500

24x2x1.5

0.7

2.0

34.7

1597

500

30x2x1.5

0.7

2.1

36.9

1900

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.1

9.8

142

1000

2x2x2.5

0.7

1.3

14.8

280

1000

3x2x2.5

0.7

1.3

15.7

351

1000

4x2x2.5

0.7

1.4

17.4

442

1000

5x2x2.5

0.7

1.4

19.2

553

1000

6x2x2.5

0.7

1.5

21.0

642

1000

7x2x2.5

0.7

1.5

21.0

707

1000

10x2x2.5

0.7

1.7

27.0

1003

500

12x2x2.5

0.7

1.7

27.9

1157

500

16x2x2.5

0.7

1.9

31.4

1483

500

20x2x2.5

0.7

2.0

35.1

1828

500

24x2x2.5

0.7

2.1

39.0

2154

500

30x2x2.5

0.7

2.2

41.5

2595

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2XCH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

43

KCI

RE-YCY
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Braid of Copper Wires
Screen
Outer Sheath
Extruded PVC

+70 oC

IEC 60332-1

Instrument Cables

Criteria

44

Conductor cross section

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.6

1.0

7.4

76

1000

2x3x0.5

0.6

1.1

10.9

136

1000

3x3x0.5

0.6

1.2

11.7

172

1000

4x3x0.5

0.6

1.2

12.9

231

1000

5x3x0.5

0.6

1.3

14.2

271

1000

6x3x0.5

0.6

1.3

15.4

314

1000

7x3x0.5

0.6

1.3

15.4

341

1000

10x3x0.5

0.6

1.5

20.0

509

1000

12x3x0.5

0.6

1.5

20.6

568

1000

16x3x0.5

0.6

1.6

22.9

718

1000

20x3x0.5

0.6

1.7

25.6

869

500

24x3x0.5

0.6

1.8

28.4

1033

500

30x3x0.5

0.6

1.8

30.0

1214

500

1x3x0.75

0.6

1.0

7.8

91

1000

2x3x0.75

0.6

1.2

11.9

164

1000

3x3x0.75

0.6

1.2

12.8

224

1000

4x3x0.75

0.6

1.3

14.1

281

1000

5x3x0.75

0.6

1.3

15.3

332

1000

6x3x0.75

0.6

1.4

16.8

393

1000

7x3x0.75

0.6

1.4

16.8

429

1000

10x3x0.75

0.6

1.5

21.5

628

1000

12x3x0.75

0.6

1.6

22.4

717

1000

16x3x0.75

0.6

1.6

24.8

891

500

20x3x0.75

0.6

1.8

27.9

1104

500

24x3x0.75

0.6

1.9

31.0

1298

500

30x3x0.75

0.6

1.9

32.7

1538

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

45

KCI

RE-YCY

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

1.0

8.2

103

1000

2x3x1

0.6

1.2

12.7

206

1000

3x3x1

0.6

1.2

13.5

263

1000

4x3x1

0.6

1.3

14.9

330

1000

5x3x1

0.6

1.3

16.2

385

1000

6x3x1

0.6

1.4

17.8

456

1000

7x3x1

0.6

1.4

17.8

501

1000

10x3x1

0.6

1.6

23.1

743

1000

12x3x1

0.6

1.6

23.8

840

1000

16x3x1

0.6

1.7

26.5

1067

500

20x3x1

0.6

1.8

29.7

1309

500

24x3x1

0.6

1.9

33.0

1545

500

30x3x1

0.6

2.0

35.1

1878

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

46

1x3x1.5

0.7

1.1

9.5

138

1000

2x3x1.5

0.7

1.3

14.8

283

1000

3x3x1.5

0.7

1.3

15.7

356

1000

4x3x1.5

0.7

1.4

17.4

449

1000

5x3x1.5

0.7

1.4

19.2

561

1000

6x3x1.5

0.7

1.5

21.0

652

1000

7x3x1.5

0.7

1.5

21.0

719

1000

10x3x1.5

0.7

1.7

27.0

1019

500

12x3x1.5

0.7

1.7

27.9

1177

500

16x3x1.5

0.7

1.9

31.3

1510

500

20x3x1.5

0.7

2.0

35.0

1862

500

24x3x1.5

0.7

2.1

39.0

2195

500

30x3x1.5

0.7

2.2

41.5

2646

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.1

10.4

178

1000

2x3x2.5

0.7

1.3

16.4

363

1000

3x3x2.5

0.7

1.4

17.6

477

1000

4x3x2.5

0.7

1.4

19.5

621

1000

5x3x2.5

0.7

1.5

21.5

756

1000

6x3x2.5

0.7

1.6

23.6

883

1000

7x3x2.5

0.7

1.6

23.6

980

1000

10x3x2.5

0.7

1.8

30.4

1393

500

12x3x2.5

0.7

1.9

31.6

1616

500

16x3x2.5

0.7

2.0

35.2

2090

500

20x3x2.5

0.7

2.1

39.4

2550

500

24x3x2.5

0.7

2.3

44.1

3055

500

30x3x2.5

0.7

2.4

46.9

3702

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2XCH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

47

KCI

RE-YCY , PiMF
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+70 oC

Instrument Cables

48

IEC 60708 Full color

Braid of Copper wires


Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.6

1.0

7.4

84

1000

2x2x0.5

0.6

1.2

11.3

157

1000

3x2x0.5

0.6

1.2

12.2

214

1000

4x2x0.5

0.6

1.2

13.3

262

1000

5x2x0.5

0.6

1.3

14.6

310

1000

6x2x0.5

0.6

1.3

15.8

361

1000

7x2x0.5

0.6

1.3

15.8

395

1000

10x2x0.5

0.6

1.5

20.5

587

1000

12x2x0.5

0.6

1.5

21.1

661

1000

16x2x0.5

0.6

1.6

23.5

841

1000

20x2x0.5

0.6

1.7

26.3

1023

500

24x2x0.5

0.6

1.8

29.2

1219

500

30x2x0.5

0.6

1.9

31.1

1458

500

1x2x0.75

0.6

1.0

7.8

96

1000

2x2x0.75

0.6

1.2

12.3

194

1000

3x2x0.75

0.6

1.2

13.0

246

1000

4x2x0.75

0.6

1.3

14.4

301

1000

5x2x0.75

0.6

1.3

15.6

357

1000

6x2x0.75

0.6

1.4

17.1

423

1000

7x2x0.75

0.6

1.4

17.1

463

1000

10x2x0.75

0.6

1.5

22.0

678

1000

12x2x0.75

0.6

1.6

22.9

776

1000

16x2x0.75

0.6

1.7

25.5

982

500

20x2x0.75

0.6

1.8

28.5

1203

500

24x2x0.75

0.6

1.9

31.6

1417

500

30x2x0.75

0.6

2.0

33.6

1700

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

49

KCI

RE-YCY , PiMF

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

1.0

8.2

98

1000

2x2x1

0.6

1.2

12.9

206

1000

3x2x1

0.6

1.2

13.7

253

1000

4x2x1

0.6

1.3

15.1

316

1000

5x2x1

0.6

1.3

16.5

374

1000

6x2x1

0.6

1.4

18.1

434

1000

7x2x1

0.6

1.4

18.1

475

1000

10x2x1

0.6

1.6

23.5

707

1000

12x2x1

0.6

1.6

24.2

797

1000

16x2x1

0.6

1.7

27.0

1009

500

20x2x1

0.6

1.8

30.2

1237

500

24x2x1

0.6

1.9

33.6

1458

500

30x2x1

0.6

2.0

35.7

1768

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

50

1x2x1.5

0.7

1.1

9.4

127

1000

2x2x1.5

0.7

1.3

14.9

263

1000

3x2x1.5

0.7

1.3

15.8

326

1000

4x2x1.5

0.7

1.4

17.5

408

1000

5x2x1.5

0.7

1.4

19.3

511

1000

6x2x1.5

0.7

1.5

21.2

591

1000

7x2x1.5

0.7

1.5

21.2

648

1000

10x2x1.5

0.7

1.7

27.2

918

500

12x2x1.5

0.7

1.7

28.1

1055

500

16x2x1.5

0.7

1.9

31.6

1347

500

20x2x1.5

0.7

2.0

35.3

1657

500

24x2x1.5

0.7

2.1

39.3

1950

500

30x2x1.5

0.7

2.2

41.8

2354

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.1

10.2

159

1000

2x2x2.5

0.7

1.3

16.4

328

1000

3x2x2.5

0.7

1.4

17.6

424

1000

4x2x2.5

0.7

1.4

19.5

551

1000

5x2x2.5

0.7

1.5

21.5

669

1000

6x2x2.5

0.7

1.6

23.6

778

1000

7x2x2.5

0.7

1.6

23.6

858

1000

10x2x2.5

0.7

1.8

30.4

1218

500

12x2x2.5

0.7

1.9

31.6

1406

500

16x2x2.5

0.7

2.0

35.3

1810

500

20x2x2.5

0.7

2.1

39.5

2200

500

24x2x2.5

0.7

2.3

44.2

2635

500

30x2x2.5

0.7

2.4

47.0

3177

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2XCH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

51

KCI

RE-YCY , TiMF
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+70 oC

Instrument Cables

52

Conductor cross section

PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Braid of Copper Wires
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.6

1.0

7.7

98

1000

2x3x0.5

0.6

1.2

12.6

202

1000

3x3x0.5

0.6

1.2

13.4

257

1000

4x3x0.5

0.6

1.3

14.8

322

1000

5x3x0.5

0.6

1.3

16.1

374

1000

6x3x0.5

0.6

1.4

17.6

443

1000

7x3x0.5

0.6

1.4

17.6

486

1000

10x3x0.5

0.6

1.6

22.9

722

1000

12x3x0.5

0.6

1.6

23.6

816

1000

16x3x0.5

0.6

1.7

26.3

1034

500

20x3x0.5

0.6

1.8

29.4

1268

500

24x3x0.5

0.6

1.9

32.7

1496

500

30x3x0.5

0.6

2.0

34.7

1824

500

1x3x0.75

0.6

1.0

8.2

110

1000

2x3x0.75

0.6

1.2

13.5

233

1000

3x3x0.75

0.6

1.3

14.5

298

1000

4x3x0.75

0.6

1.3

15.8

367

1000

5x3x0.75

0.6

1.4

17.4

446

1000

6x3x0.75

0.6

1.4

19.1

544

1000

7x3x0.75

0.6

1.4

19.1

597

1000

10x3x0.75

0.6

1.6

24.6

835

500

12x3x0.75

0.6

1.7

25.6

968

500

16x3x0.75

0.6

1.8

28.5

1237

500

20x3x0.75

0.6

1.9

31.8

1503

500

24x3x0.75

0.6

2.0

35.4

1797

500

30x3x0.75

0.6

2.1

37.7

2157

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

53

KCI

RE-YCY , TiMF

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

1.1

8.8

124

1000

2x3x1

0.6

1.3

14.4

252

1000

3x3x1

0.6

1.3

15.3

322

1000

4x3x1

0.6

1.3

16.7

396

1000

5x3x1

0.6

1.4

18.4

472

1000

6x3x1

0.6

1.5

20.4

585

1000

7x3x1

0.6

1.5

20.4

641

1000

10x3x1

0.6

1.7

26.2

907

500

12x3x1

0.6

1.7

27.1

1030

500

16x3x1

0.6

1.8

30.2

1318

500

20x3x1

0.6

1.9

33.8

1631

500

24x3x1

0.6

2.1

37.8

1931

500

30x3x1

0.6

2.1

40.0

2299

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

54

1x3x1.5

0.7

1.1

9.8

156

1000

2x3x1.5

0.7

1.3

16.4

327

1000

3x3x1.5

0.7

1.4

17.7

421

1000

4x3x1.5

0.7

1.4

19.6

547

1000

5x3x1.5

0.7

1.5

21.6

664

1000

6x3x1.5

0.7

1.6

23.7

773

1000

7x3x1.5

0.7

1.6

23.7

852

1000

10x3x1.5

0.7

1.8

30.5

1209

500

12x3x1.5

0.7

1.9

31.7

1395

500

16x3x1.5

0.7

2.0

35.4

1795

500

20x3x1.5

0.7

2.1

39.6

2181

500

24x3x1.5

0.7

2.3

44.3

2613

500

30x3x1.5

0.7

2.4

47.1

3149

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-YCY , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.1

10.7

195

1000

2x3x2.5

0.7

1.4

18.4

416

1000

3x3x2.5

0.7

1.4

19.7

572

1000

4x3x2.5

0.7

1.5

21.8

724

1000

5x3x2.5

0.7

1.6

24.1

867

1000

6x3x2.5

0.7

1.7

26.4

1023

500

7x3x2.5

0.7

1.7

26.4

1136

500

10x3x2.5

0.7

2.0

34.3

1652

500

12x3x2.5

0.7

2.0

35.4

1887

500

16x3x2.5

0.7

2.1

39.6

2408

500

20x3x2.5

0.7

2.3

44.5

2980

500

24x3x2.5

0.7

2.5

49.8

3577

500

30x3x2.5

0.7

2.6

53.0

4331

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2XCH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

55

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)YQY
IEC 60092-376

150/250 V (300 V)

RE-2X(St)YQY Multi-Core
RE-2X(St)YQY Multi-Pair
RE-2X(St)YQY Multi-Triple
RE-2X(St)YQY PiMF
RE-2X(St)YQY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-2X(St)QY
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

Instrument Cables

58

XLPE
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)QY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.4

0.2

5.7

1.1

8.8

117

1000

3x0.5

0.4

0.2

6.0

1.1

9.1

126

1000

4x0.5

0.4

0.2

6.4

1.1

9.5

137

1000

5x0.5

0.4

0.2

6.9

1.1

10.0

148

1000

6x0.5

0.4

0.2

7.4

1.1

10.5

166

1000

7x0.5

0.4

0.2

7.4

1.1

10.5

172

1000

8x0.5

0.4

0.2

8.4

1.2

11.7

201

1000

10x0.5

0.4

0.2

9.1

1.2

12.4

221

1000

12x0.5

0.4

0.2

9.4

1.2

12.7

236

1000

16x0.5

0.4

0.2

10.3

1.3

13.8

284

1000

20x0.5

0.4

0.3

11.3

1.3

15.3

359

1000

24x0.5

0.4

0.3

12.5

1.4

16.6

405

1000

30x0.5

0.4

0.3

13.2

1.4

17.3

451

1000

2x0.75

0.5

0.2

6.5

1.1

9.6

132

1000

3x0.75

0.5

0.2

6.8

1.1

9.9

145

1000

4x0.75

0.5

0.2

7.4

1.1

10.5

167

1000

5x0.75

0.5

0.2

8.0

1.2

11.3

188

1000

6x0.75

0.5

0.2

8.6

1.2

11.9

210

1000

7x0.75

0.5

0.2

8.6

1.2

11.9

220

1000

8x0.75

0.5

0.2

9.9

1.2

13.2

243

1000

10x0.75

0.5

0.3

10.7

1.3

14.7

308

1000

12x0.75

0.5

0.3

11.1

1.3

15.0

345

1000

16x0.75

0.5

0.3

12.2

1.4

16.4

404

1000

20x0.75

0.5

0.3

13.5

1.4

17.7

459

1000

24x0.75

0.5

0.3

14.9

1.5

19.3

534

1000

30x0.75

0.5

0.3

15.8

1.5

20.2

621

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

59

KCI

RE-2X(St)YQY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.5

0.2

6.9

1.1

10.0

136

1000

3x1

0.5

0.2

7.2

1.1

10.3

158

1000

4x1

0.5

0.2

7.8

1.2

11.1

182

1000

5x1

0.5

0.2

8.5

1.2

11.8

207

1000

6x1

0.5

0.2

9.2

1.2

12.5

227

1000

7x1

0.5

0.2

9.2

1.2

12.5

239

1000

8x1

0.5

0.3

10.5

1.3

14.5

303

1000

10x1

0.5

0.3

11.4

1.3

15.4

353

1000

12x1

0.5

0.3

11.8

1.3

15.8

381

1000

16x1

0.5

0.3

13.1

1.4

17.2

453

1000

20x1

0.5

0.3

14.5

1.4

18.6

536

1000

24x1

0.5

0.3

16.0

1.5

20.4

627

1000

30x1

0.5

0.3

17.0

1.5

21.3

712

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

60

2x1.5

0.6

0.2

7.9

1.2

11.2

170

1000

3x1.5

0.6

0.2

8.3

1.2

11.6

193

1000

4x1.5

0.6

0.2

9.0

1.2

12.3

226

1000

5x1.5

0.6

0.2

9.8

1.2

13.1

253

1000

6x1.5

0.6

0.3

10.7

1.3

14.6

317

1000

7x1.5

0.6

0.3

10.7

1.3

14.6

335

1000

8x1.5

0.6

0.3

12.3

1.3

16.3

389

1000

10x1.5

0.6

0.3

13.4

1.4

17.6

447

1000

12x1.5

0.6

0.3

13.9

1.4

18.0

505

1000

16x1.5

0.6

0.3

15.4

1.5

19.8

621

1000

20x1.5

0.6

0.3

17.2

1.5

21.5

716

1000

24x1.5

0.6

0.3

19.0

1.6

23.6

844

1000

30x1.5

0.6

0.3

20.2

1.7

24.9

980

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.6

0.2

8.7

1.2

12.0

207

1000

3x2.5

0.6

0.2

9.2

1.2

12.5

240

1000

4x2.5

0.6

0.2

10.1

1.2

13.4

284

1000

5x2.5

0.6

0.3

11.0

1.3

14.9

366

1000

6x2.5

0.6

0.3

11.9

1.3

15.9

406

1000

7x2.5

0.6

0.3

11.9

1.3

15.9

433

1000

8x2.5

0.6

0.3

13.8

1.4

18.0

508

1000

10x2.5

0.6

0.3

15.1

1.5

19.5

583

1000

12x2.5

0.6

0.3

15.6

1.5

20.0

665

1000

16x2.5

0.6

0.3

17.4

1.5

21.7

798

1000

20x2.5

0.6

0.3

19.4

1.6

23.9

965

1000

24x2.5

0.6

0.3

21.5

1.7

26.3

1116

500

30x2.5

0.6

0.3

22.9

1.8

27.8

1333

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

61

KCI

RE-2X(St)YQY
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

Instrument Cables

62

IEC 60708 Full color

Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.4

0.2

5.7

1.1

8.8

118

1000

2x2x0.5

0.4

0.2

7.9

1.2

11.2

164

1000

3x2x0.5

0.4

0.2

8.3

1.2

11.6

182

1000

4x2x0.5

0.4

0.2

9.0

1.2

12.3

209

1000

5x2x0.5

0.4

0.2

9.8

1.2

13.1

230

1000

6x2x0.5

0.4

0.3

10.7

1.3

14.6

288

1000

7x2x0.5

0.4

0.3

10.7

1.3

14.6

301

1000

10x2x0.5

0.4

0.3

13.4

1.4

17.6

395

1000

12x2x0.5

0.4

0.3

13.9

1.4

18.0

442

1000

16x2x0.5

0.4

0.3

15.4

1.5

19.7

534

1000

20x2x0.5

0.4

0.3

17.1

1.5

21.5

607

1000

24x2x0.5

0.4

0.3

19.0

1.6

23.6

711

1000

30x2x0.5

0.4

0.3

20.2

1.7

24.9

813

500

1x2x0.75

0.5

0.2

6.5

1.1

9.6

133

1000

2x2x0.75

0.5

0.2

9.2

1.2

12.5

199

1000

3x2x0.75

0.5

0.2

9.8

1.2

13.1

224

1000

4x2x0.75

0.5

0.3

10.7

1.3

14.6

290

1000

5x2x0.75

0.5

0.3

11.6

1.3

15.6

335

1000

6x2x0.75

0.5

0.3

12.7

1.4

16.8

375

1000

7x2x0.75

0.5

0.3

12.7

1.4

16.8

394

1000

10x2x0.75

0.5

0.3

16.1

1.5

20.5

534

1000

12x2x0.75

0.5

0.3

16.7

1.5

21.0

580

1000

16x2x0.75

0.5

0.3

18.6

1.6

23.1

711

1000

20x2x0.75

0.5

0.3

20.7

1.7

25.5

828

500

24x2x0.75

0.5

0.3

23.1

1.8

28.0

969

500

30x2x0.75

0.5

0.3

24.5

1.8

29.4

1105

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

63

KCI

RE-2X(St)YQY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.5

0.2

6.9

1.1

10.0

136

1000

2x2x1

0.5

0.2

9.8

1.2

13.1

211

1000

3x2x1

0.5

0.3

10.4

1.3

14.4

278

1000

4x2x1

0.5

0.3

11.4

1.3

15.3

329

1000

5x2x1

0.5

0.3

12.4

1.3

16.4

367

1000

6x2x1

0.5

0.3

13.6

1.4

17.7

414

1000

7x2x1

0.5

0.3

13.6

1.4

17.7

439

1000

10x2x1

0.5

0.3

17.3

1.5

21.7

599

1000

12x2x1

0.5

0.3

17.9

1.5

22.3

656

1000

16x2x1

0.5

0.3

19.9

1.6

24.5

812

1000

20x2x1

0.5

0.3

22.3

1.7

27.1

975

500

24x2x1

0.5

0.3

24.8

1.8

29.8

1122

500

30x2x1

0.5

0.3

26.4

1.9

31.5

1328

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

64

1x2x1.5

0.6

0.2

7.9

1.2

11.2

171

1000

2x2x1.5

0.6

0.3

11.4

1.3

15.4

306

1000

3x2x1.5

0.6

0.3

12.2

1.3

16.1

352

1000

4x2x1.5

0.6

0.3

13.4

1.4

17.5

412

1000

5x2x1.5

0.6

0.3

14.6

1.4

18.8

482

1000

6x2x1.5

0.6

0.3

16.0

1.5

20.4

559

1000

7x2x1.5

0.6

0.3

16.0

1.5

20.4

597

1000

10x2x1.5

0.6

0.3

20.6

1.7

25.3

810

500

12x2x1.5

0.6

0.3

21.3

1.7

26.1

894

500

16x2x1.5

0.6

0.3

23.8

1.8

28.7

1111

500

20x2x1.5

0.6

0.3

26.7

1.9

31.8

1337

500

24x2x1.5

0.6

0.3

30.1

2.0

35.5

1601

500

30x2x1.5

0.6

0.4

32.0

2.1

38.0

1969

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.6

0.2

8.7

1.2

12.0

208

1000

2x2x2.5

0.6

0.3

12.8

1.4

17.0

371

1000

3x2x2.5

0.6

0.3

13.7

1.4

17.8

454

1000

4x2x2.5

0.6

0.3

15.0

1.4

19.2

522

1000

5x2x2.5

0.6

0.3

16.5

1.5

20.9

626

1000

6x2x2.5

0.6

0.3

18.1

1.6

22.6

713

1000

7x2x2.5

0.6

0.3

18.1

1.6

22.6

769

1000

10x2x2.5

0.6

0.3

23.3

1.8

28.3

1074

500

12x2x2.5

0.6

0.3

24.2

1.8

29.1

1199

500

16x2x2.5

0.6

0.3

27.0

1.9

32.2

1501

500

20x2x2.5

0.6

0.3

30.7

2.0

36.1

1846

500

24x2x2.5

0.6

0.4

34.3

2.2

40.5

2263

500

30x2x2.5

0.6

0.4

36.4

2.3

42.8

2700

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

65

KCI

RE-2X(St)YQY
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Braid of Galvanized Steel Wires
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

Instrument Cables

Criteria

66

Conductor cross section

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.4

0.2

6.0

1.1

9.1

127

1000

2x3x0.5

0.4

0.2

8.6

1.2

11.9

192

1000

3x3x0.5

0.4

0.2

9.1

1.2

12.4

216

1000

4x3x0.5

0.4

0.2

10.0

1.2

13.3

251

1000

5x3x0.5

0.4

0.3

10.9

1.3

14.8

324

1000

6x3x0.5

0.4

0.3

11.8

1.3

15.8

355

1000

7x3x0.5

0.4

0.3

11.8

1.3

15.8

373

1000

10x3x0.5

0.4

0.3

15.0

1.5

19.3

497

1000

12x3x0.5

0.4

0.3

15.5

1.5

19.9

561

1000

16x3x0.5

0.4

0.3

17.2

1.5

21.6

658

1000

20x3x0.5

0.4

0.3

19.2

1.6

23.8

789

1000

24x3x0.5

0.4

0.3

21.3

1.7

26.1

904

500

30x3x0.5

0.4

0.3

22.6

1.7

27.4

1056

500

1x3x0.75

0.5

0.2

6.8

1.1

9.9

146

1000

2x3x0.75

0.5

0.2

10.2

1.2

13.5

235

1000

3x3x0.75

0.5

0.3

10.8

1.3

14.8

315

1000

4x3x0.75

0.5

0.3

11.8

1.3

15.8

357

1000

5x3x0.75

0.5

0.3

12.9

1.4

17.1

407

1000

6x3x0.75

0.5

0.3

14.1

1.4

18.3

467

1000

7x3x0.75

0.5

0.3

14.1

1.4

18.3

495

1000

10x3x0.75

0.5

0.3

18.1

1.6

22.6

665

1000

12x3x0.75

0.5

0.3

18.7

1.6

23.2

751

1000

16x3x0.75

0.5

0.3

20.8

1.7

25.6

906

500

20x3x0.75

0.5

0.3

23.3

1.8

28.3

1088

500

24x3x0.75

0.5

0.3

25.9

1.9

31.1

1276

500

30x3x0.75

0.5

0.3

28.0

2.0

33.3

1518

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

67

KCI

RE-2X(St)YQY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.5

0.2

7.2

1.1

10.3

159

1000

2x3x1

0.5

0.3

10.8

1.3

14.8

298

1000

3x3x1

0.5

0.3

11.5

1.3

15.5

344

1000

4x3x1

0.5

0.3

12.6

1.3

16.6

395

1000

5x3x1

0.5

0.3

13.8

1.4

18.0

470

1000

6x3x1

0.5

0.3

15.1

1.4

19.3

518

1000

7x3x1

0.5

0.3

15.1

1.4

19.3

555

1000

10x3x1

0.5

0.3

19.4

1.6

24.0

781

1000

12x3x1

0.5

0.3

20.1

1.6

24.6

864

500

16x3x1

0.5

0.3

22.4

1.7

27.1

1076

500

20x3x1

0.5

0.3

25.1

1.8

30.0

1275

500

24x3x1

0.5

0.3

28.0

1.9

33.1

1501

500

30x3x1

0.5

0.3

30.1

2.0

35.5

1819

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

68

1x3x1.5

0.6

0.2

8.3

1.2

11.6

194

1000

2x3x1.5

0.6

0.3

12.7

1.4

16.9

367

1000

3x3x1.5

0.6

0.3

13.5

1.4

17.7

434

1000

4x3x1.5

0.6

0.3

14.9

1.4

19.1

517

1000

5x3x1.5

0.6

0.3

16.4

1.5

20.7

620

1000

6x3x1.5

0.6

0.3

17.9

1.6

22.5

706

1000

7x3x1.5

0.6

0.3

17.9

1.6

22.5

762

1000

10x3x1.5

0.6

0.3

23.1

1.8

28.1

1065

500

12x3x1.5

0.6

0.3

24.0

1.8

28.9

1188

500

16x3x1.5

0.6

0.3

26.8

1.9

31.9

1488

500

20x3x1.5

0.6

0.3

30.5

2.0

35.8

1831

500

24x3x1.5

0.6

0.4

34.0

2.2

40.2

2245

500

30x3x1.5

0.6

0.4

36.1

2.3

42.5

2679

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.6

0.2

9.2

1.2

12.5

242

1000

2x3x2.5

0.6

0.3

14.3

1.4

18.4

462

1000

3x3x2.5

0.6

0.3

15.2

1.5

19.6

562

1000

4x3x2.5

0.6

0.3

16.8

1.5

21.2

686

1000

5x3x2.5

0.6

0.3

18.5

1.6

23.0

803

1000

6x3x2.5

0.6

0.3

20.3

1.6

24.8

931

500

7x3x2.5

0.6

0.3

20.3

1.6

24.8

1016

500

10x3x2.5

0.6

0.3

26.3

1.9

31.4

1434

500

12x3x2.5

0.6

0.3

27.2

1.9

32.4

1617

500

16x3x2.5

0.6

0.3

30.9

2.0

36.2

2074

500

20x3x2.5

0.6

0.4

34.7

2.2

40.9

2609

500

24x3x2.5

0.6

0.4

38.7

2.4

45.3

3102

500

30x3x2.5

0.6

0.4

41.5

2.5

48.3

3763

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

69

KCI

RE-2X(St)YQY , PiMF
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

Instrument Cables

70

IEC 60708 Full color

XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.4

0.2

6.0

1.1

9.1

137

1000

2x2x0.5

0.4

0.2

9.0

1.2

12.3

214

1000

3x2x0.5

0.4

0.2

9.5

1.2

12.8

248

1000

4x2x0.5

0.4

0.2

10.4

1.2

13.7

292

1000

5x2x0.5

0.4

0.3

11.3

1.3

15.3

376

1000

6x2x0.5

0.4

0.3

12.3

1.3

16.3

416

1000

7x2x0.5

0.4

0.3

12.3

1.3

16.3

445

1000

10x2x0.5

0.4

0.3

15.7

1.5

20.0

618

1000

12x2x0.5

0.4

0.3

16.2

1.5

20.5

681

1000

16x2x0.5

0.4

0.3

18.0

1.6

22.5

826

1000

20x2x0.5

0.4

0.3

20.1

1.6

24.7

986

500

24x2x0.5

0.4

0.3

22.3

1.7

27.1

1161

500

30x2x0.5

0.4

0.3

23.7

1.8

28.7

1362

500

1x2x0.75

0.5

0.2

6.9

1.1

10.0

153

1000

2x2x0.75

0.5

0.3

10.4

1.3

14.4

281

1000

3x2x0.75

0.5

0.3

11.1

1.3

15.0

339

1000

4x2x0.75

0.5

0.3

12.1

1.3

16.1

387

1000

5x2x0.75

0.5

0.3

13.3

1.4

17.4

445

1000

6x2x0.75

0.5

0.3

14.5

1.4

18.7

511

1000

7x2x0.75

0.5

0.3

14.5

1.4

18.7

547

1000

10x2x0.75

0.5

0.3

18.6

1.6

23.1

758

1000

12x2x0.75

0.5

0.3

19.2

1.6

23.8

837

1000

16x2x0.75

0.5

0.3

21.4

1.7

26.2

1020

500

20x2x0.75

0.5

0.3

24.0

1.8

28.9

1230

500

24x2x0.75

0.5

0.3

26.7

1.9

31.9

1446

500

30x2x0.75

0.5

0.3

28.8

2.0

34.1

1729

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

71

KCI

RE-2X(St)YQY , PiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.5

0.2

7.2

1.1

10.3

157

1000

2x2x1

0.5

0.3

11.1

1.3

15.0

297

1000

3x2x1

0.5

0.3

11.8

1.3

15.7

342

1000

4x2x1

0.5

0.3

12.9

1.4

17.1

399

1000

5x2x1

0.5

0.3

14.1

1.4

18.3

466

1000

6x2x1

0.5

0.3

15.5

1.5

19.8

542

1000

7x2x1

0.5

0.3

15.5

1.5

19.8

577

1000

10x2x1

0.5

0.3

19.9

1.6

24.4

770

1000

12x2x1

0.5

0.3

20.6

1.6

25.1

850

500

16x2x1

0.5

0.3

22.9

1.7

27.7

1057

500

20x2x1

0.5

0.3

25.7

1.8

30.6

1272

500

24x2x1

0.5

0.3

29.0

2.0

34.4

1539

500

30x2x1

0.5

0.3

30.8

2.0

36.2

1781

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

72

1x2x1.5

0.6

0.2

8.2

1.2

11.5

186

1000

2x2x1.5

0.6

0.3

12.8

1.4

17.0

354

1000

3x2x1.5

0.6

0.3

13.7

1.4

17.8

429

1000

4x2x1.5

0.6

0.3

15.1

1.4

19.2

490

1000

5x2x1.5

0.6

0.3

16.5

1.5

20.9

586

1000

6x2x1.5

0.6

0.3

18.1

1.6

22.7

665

1000

7x2x1.5

0.6

0.3

18.1

1.6

22.7

714

1000

10x2x1.5

0.6

0.3

23.4

1.8

28.4

997

500

12x2x1.5

0.6

0.3

24.3

1.8

29.2

1107

500

16x2x1.5

0.6

0.3

27.1

1.9

32.3

1379

500

20x2x1.5

0.6

0.3

30.8

2.0

36.2

1694

500

24x2x1.5

0.6

0.4

34.4

2.2

40.6

2081

500

30x2x1.5

0.6

0.4

36.5

2.3

42.9

2472

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.6

0.2

9.1

1.2

12.4

227

1000

2x2x2.5

0.6

0.3

14.3

1.4

18.5

436

1000

3x2x2.5

0.6

0.3

15.3

1.5

19.7

542

1000

4x2x2.5

0.6

0.3

16.9

1.5

21.2

633

1000

5x2x2.5

0.6

0.3

18.6

1.6

23.1

756

1000

6x2x2.5

0.6

0.3

20.4

1.6

24.9

851

500

7x2x2.5

0.6

0.3

20.4

1.6

24.9

922

500

10x2x2.5

0.6

0.3

26.4

1.9

31.5

1299

500

12x2x2.5

0.6

0.3

27.4

1.9

32.5

1456

500

16x2x2.5

0.6

0.4

31.0

2.1

37.0

1971

500

20x2x2.5

0.6

0.4

34.8

2.2

41.0

2340

500

24x2x2.5

0.6

0.4

38.9

2.4

45.5

2779

500

30x2x2.5

0.6

0.4

41.7

2.5

48.5

3359

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

73

KCI

RE-2X(St)YQY , TiMF
150/250 V (300 V)

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

Instrument Cables

74

Conductor cross section

XLPE
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YQY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)
Insulation
thickness

IEC 60092-376

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.4

0.2

6.3

1.1

9.4

146

1000

2x3x0.5

0.4

0.2

9.9

1.2

13.2

237

1000

3x3x0.5

0.4

0.3

10.5

1.3

14.4

314

1000

4x3x0.5

0.4

0.3

11.5

1.3

15.4

375

1000

5x3x0.5

0.4

0.3

12.5

1.4

16.7

431

1000

6x3x0.5

0.4

0.3

13.6

1.4

17.8

495

1000

7x3x0.5

0.4

0.3

13.6

1.4

17.8

530

1000

10x3x0.5

0.4

0.3

17.4

1.5

21.8

705

1000

12x3x0.5

0.4

0.3

18.0

1.6

22.6

792

1000

16x3x0.5

0.4

0.3

20.1

1.6

24.6

978

500

20x3x0.5

0.4

0.3

22.5

1.7

27.2

1181

500

24x3x0.5

0.4

0.3

25.0

1.8

30.0

1367

500

30x3x0.5

0.4

0.3

26.6

1.9

31.7

1633

500

1x3x0.75

0.5

0.2

7.2

1.1

10.3

172

1000

2x3x0.75

0.5

0.3

11.5

1.3

15.5

328

1000

3x3x0.75

0.5

0.3

12.3

1.3

16.2

383

1000

4x3x0.75

0.5

0.3

13.5

1.4

17.6

451

1000

5x3x0.75

0.5

0.3

14.8

1.4

18.9

529

1000

6x3x0.75

0.5

0.3

16.1

1.5

20.5

614

1000

7x3x0.75

0.5

0.3

16.1

1.5

20.5

660

1000

10x3x0.75

0.5

0.3

20.8

1.7

25.5

897

500

12x3x0.75

0.5

0.3

21.5

1.7

26.2

997

500

16x3x0.75

0.5

0.3

24.0

1.8

28.9

1247

500

20x3x0.75

0.5

0.3

26.9

1.9

32.0

1505

500

24x3x0.75

0.5

0.3

30.4

2.0

35.7

1801

500

30x3x0.75

0.5

0.4

32.3

2.1

38.3

2217

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

75

KCI

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

RE-2X(St)YQY , TiMF

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.5

0.2

7.6

1.1

10.7

174

1000

2x3x1

0.5

0.3

12.3

1.3

16.2

338

1000

3x3x1

0.5

0.3

13.1

1.4

17.2

404

1000

4x3x1

0.5

0.3

14.3

1.4

18.5

484

1000

5x3x1

0.5

0.3

15.7

1.5

20.1

573

1000

6x3x1

0.5

0.3

17.2

1.5

21.6

640

1000

7x3x1

0.5

0.3

17.2

1.5

21.6

688

1000

10x3x1

0.5

0.3

22.2

1.7

27.0

961

500

12x3x1

0.5

0.3

23.0

1.7

27.8

1068

500

16x3x1

0.5

0.3

25.7

1.8

30.7

1333

500

20x3x1

0.5

0.3

29.2

2.0

34.6

1654

500

24x3x1

0.5

0.4

32.6

2.1

38.6

2015

500

30x3x1

0.5

0.4

34.6

2.2

40.8

2358

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

76

1x3x1.5

0.6

0.2

8.7

1.2

12.0

217

1000

2x3x1.5

0.6

0.3

14.3

1.4

18.4

426

1000

3x3x1.5

0.6

0.3

15.2

1.4

19.4

500

1000

4x3x1.5

0.6

0.3

16.8

1.5

21.2

617

1000

5x3x1.5

0.6

0.3

18.5

1.6

23.0

716

1000

6x3x1.5

0.6

0.3

20.3

1.6

24.8

828

500

7x3x1.5

0.6

0.3

20.3

1.6

24.8

896

500

10x3x1.5

0.6

0.3

26.3

1.9

31.4

1263

500

12x3x1.5

0.6

0.3

27.2

1.9

32.4

1413

500

16x3x1.5

0.6

0.3

30.9

2.0

36.2

1803

500

20x3x1.5

0.6

0.4

34.7

2.2

40.9

2271

500

24x3x1.5

0.6

0.4

38.7

2.4

45.3

2696

500

30x3x1.5

0.6

0.4

41.5

2.5

48.3

3258

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Insulation
thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY , TiMF

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.6

0.2

9.6

1.2

12.9

261

1000

2x3x2.5

0.6

0.3

16.0

1.5

20.3

537

1000

3x3x2.5

0.6

0.3

17.1

1.5

21.4

650

1000

4x3x2.5

0.6

0.3

18.9

1.6

23.4

803

1000

5x3x2.5

0.6

0.3

20.8

1.7

25.5

940

500

6x3x2.5

0.6

0.3

22.8

1.7

27.6

1088

500

7x3x2.5

0.6

0.3

22.8

1.7

27.6

1188

500

10x3x2.5

0.6

0.3

30.1

2.0

35.4

1703

500

12x3x2.5

0.6

0.4

31.2

2.1

37.2

2033

500

16x3x2.5

0.6

0.4

34.9

2.2

41.1

2515

500

20x3x2.5

0.6

0.4

39.2

2.4

45.8

3074

500

24x3x2.5

0.6

0.4

44.2

2.6

51.2

3695

250

30x3x2.5

0.6

0.4

47.0

2.7

54.2

4379

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

77

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)YQY Fire Resistant
IEC 60092-376 150/250 V (300 V)
RE-2X(St)YQY Multi-Core
RE-2X(St)YQY Multi-Pair
RE-2X(St)YQY Multi-Triple
RE-2X(St)YQY PiMF
RE-2X(St)YQY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH

Fire Resistant

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

RE-2X(St)QY

IEC 60092-376

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

KCI

150/250 V (300 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

80

Mica-glass Tape + XLPE


Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Yellow or White (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

IEC 60092-376

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)QY

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.4

0.2

6.6

1.1

9.7

131

1000

3x0.5

0.4

0.2

7.0

1.1

10.1

149

1000

4x0.5

0.4

0.2

7.6

1.1

10.7

163

1000

5x0.5

0.4

0.2

8.2

1.1

11.3

177

1000

6x0.5

0.4

0.2

8.8

1.2

12.1

204

1000

7x0.5

0.4

0.2

8.8

1.2

12.1

212

1000

8x0.5

0.4

0.2

10.1

1.2

13.4

241

1000

10x0.5

0.4

0.3

11.0

1.3

15.0

311

1000

12x0.5

0.4

0.3

11.4

1.3

15.3

331

1000

16x0.5

0.4

0.3

12.5

1.3

16.5

378

1000

20x0.5

0.4

0.3

13.9

1.4

18.1

450

1000

24x0.5

0.4

0.3

15.4

1.4

19.5

515

1000

30x0.5

0.4

0.3

16.3

1.4

20.4

574

1000

2x0.75

0.5

0.2

7.5

1.1

10.6

153

1000

3x0.75

0.5

0.2

7.9

1.1

11.0

169

1000

4x0.75

0.5

0.2

8.6

1.2

11.9

199

1000

5x0.75

0.5

0.2

9.3

1.2

12.6

219

1000

6x0.75

0.5

0.2

10.1

1.2

13.4

245

1000

7x0.75

0.5

0.2

10.1

1.2

13.4

257

1000

8x0.75

0.5

0.3

11.6

1.3

15.6

331

1000

10x0.75

0.5

0.3

12.6

1.3

16.6

367

1000

12x0.75

0.5

0.3

13.1

1.3

17.0

395

1000

16x0.75

0.5

0.3

14.5

1.4

18.6

483

1000

20x0.75

0.5

0.3

16.1

1.5

20.4

573

1000

24x0.75

0.5

0.3

17.8

1.5

22.2

640

1000

30x0.75

0.5

0.3

18.9

1.5

23.2

743

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

81

KCI

RE-2X(St)YQY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.5

0.2

7.8

1.1

10.9

157

1000

3x1

0.5

0.2

8.3

1.1

11.4

176

1000

4x1

0.5

0.2

9.0

1.2

12.3

210

1000

5x1

0.5

0.2

9.8

1.2

13.1

233

1000

6x1

0.5

0.3

10.6

1.2

14.3

286

1000

7x1

0.5

0.3

10.6

1.2

14.3

300

1000

8x1

0.5

0.3

12.3

1.3

16.2

356

1000

10x1

0.5

0.3

13.4

1.3

17.3

399

1000

12x1

0.5

0.3

13.8

1.4

18.0

457

1000

16x1

0.5

0.3

15.3

1.4

19.5

548

1000

20x1

0.5

0.3

17.1

1.5

21.4

636

1000

24x1

0.5

0.3

18.9

1.5

23.3

737

1000

30x1

0.5

0.3

20.0

1.6

24.6

849

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

82

2x1.5

0.6

0.2

8.8

1.2

12.1

192

1000

3x1.5

0.6

0.2

9.4

1.2

12.7

219

1000

4x1.5

0.6

0.2

10.2

1.2

13.5

256

1000

5x1.5

0.6

0.3

11.1

1.3

15.1

331

1000

6x1.5

0.6

0.3

12.1

1.3

16.0

365

1000

7x1.5

0.6

0.3

12.1

1.3

16.0

385

1000

8x1.5

0.6

0.3

14.1

1.4

18.2

454

1000

10x1.5

0.6

0.3

15.4

1.4

19.5

527

1000

12x1.5

0.6

0.3

15.9

1.4

20.0

575

1000

16x1.5

0.6

0.3

17.7

1.5

22.0

690

1000

20x1.5

0.6

0.3

19.7

1.6

24.3

831

1000

24x1.5

0.6

0.3

21.9

1.7

26.7

976

500

30x1.5

0.6

0.3

23.2

1.7

28.0

1119

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

IEC 60092-376

Sheath thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.6

0.2

9.7

1.2

13.0

223

1000

3x2.5

0.6

0.2

10.3

1.2

13.6

266

1000

4x2.5

0.6

0.3

11.2

1.3

15.2

353

1000

5x2.5

0.6

0.3

12.3

1.3

16.2

396

1000

6x2.5

0.6

0.3

13.4

1.4

17.5

448

1000

7x2.5

0.6

0.3

13.4

1.4

17.5

479

1000

8x2.5

0.6

0.3

15.6

1.4

19.7

567

1000

10x2.5

0.6

0.3

17.0

1.5

21.4

655

1000

12x2.5

0.6

0.3

17.6

1.5

22.0

723

1000

16x2.5

0.6

0.3

19.6

1.6

24.2

902

1000

20x2.5

0.6

0.3

22.0

1.7

26.7

1087

500

24x2.5

0.6

0.3

24.4

1.8

29.4

1256

500

30x2.5

0.6

0.3

25.9

1.8

30.9

1481

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

83

KCI

RE-2X(St)YQY
IEC 60092-376

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

150/250 V (300 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria

84

Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60331

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Fire Resistant

Sheath thickness

RE-2X(St)YQY

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.4

0.2

6.6

1.1

9.7

131

1000

2x2x0.5

0.4

0.2

9.4

1.2

12.7

195

1000

3x2x0.5

0.4

0.2

10.0

1.2

13.3

224

1000

4x2x0.5

0.4

0.3

10.9

1.3

14.9

296

1000

5x2x0.5

0.4

0.3

11.9

1.3

15.9

324

1000

6x2x0.5

0.4

0.3

13.0

1.3

17.0

354

1000

7x2x0.5

0.4

0.3

13.0

1.3

17.0

370

1000

10x2x0.5

0.4

0.3

16.6

1.4

20.7

501

1000

12x2x0.5

0.4

0.3

17.2

1.5

21.5

550

1000

16x2x0.5

0.4

0.3

19.1

1.5

23.4

660

1000

20x2x0.5

0.4

0.3

21.3

1.6

25.9

765

500

24x2x0.5

0.4

0.3

23.7

1.7

28.5

895

500

30x2x0.5

0.4

0.3

25.2

1.7

30.0

1013

500

1x2x0.75

0.5

0.2

7.5

1.1

10.6

153

1000

2x2x0.75

0.5

0.3

10.8

1.3

14.7

261

1000

3x2x0.75

0.5

0.3

11.5

1.3

15.4

308

1000

4x2x0.75

0.5

0.3

12.6

1.3

16.5

345

1000

5x2x0.75

0.5

0.3

13.8

1.4

17.9

407

1000

6x2x0.75

0.5

0.3

15.0

1.4

19.2

441

1000

7x2x0.75

0.5

0.3

15.0

1.4

19.2

464

1000

10x2x0.75

0.5

0.3

19.3

1.6

23.8

648

1000

12x2x0.75

0.5

0.3

20.0

1.6

24.5

704

500

16x2x0.75

0.5

0.3

22.3

1.7

27.0

861

500

20x2x0.75

0.5

0.3

24.9

1.7

29.7

992

500

24x2x0.75

0.5

0.3

27.8

1.8

32.7

1161

500

30x2x0.75

0.5

0.3

29.5

1.9

34.7

1364

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

85

KCI

RE-2X(St)YQY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.5

0.2

7.8

1.1

10.9

157

1000

2x2x1

0.5

0.3

11.4

1.3

15.3

289

1000

3x2x1

0.5

0.3

12.1

1.3

16.1

327

1000

4x2x1

0.5

0.3

13.3

1.3

17.2

371

1000

5x2x1

0.5

0.3

14.6

1.4

18.7

441

1000

6x2x1

0.5

0.3

15.9

1.4

20.1

501

1000

7x2x1

0.5

0.3

15.9

1.4

20.1

530

1000

10x2x1

0.5

0.3

20.5

1.6

25.0

716

500

12x2x1

0.5

0.3

21.2

1.6

25.7

784

500

16x2x1

0.5

0.3

23.6

1.7

28.4

967

500

20x2x1

0.5

0.3

26.5

1.8

31.5

1159

500

24x2x1

0.5

0.3

29.5

1.9

34.7

1358

500

30x2x1

0.5

0.4

31.8

2.0

37.6

1707

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

86

1x2x1.5

0.6

0.2

8.8

1.2

12.1

193

1000

2x2x1.5

0.6

0.3

13.0

1.3

17.0

336

1000

3x2x1.5

0.6

0.3

13.9

1.4

18.0

412

1000

4x2x1.5

0.6

0.3

15.3

1.4

19.4

467

1000

5x2x1.5

0.6

0.3

16.8

1.5

21.1

558

1000

6x2x1.5

0.6

0.3

18.4

1.5

22.7

620

1000

7x2x1.5

0.6

0.3

18.4

1.5

22.7

663

1000

10x2x1.5

0.6

0.3

23.7

1.7

28.5

925

500

12x2x1.5

0.6

0.3

24.6

1.7

29.3

1022

500

16x2x1.5

0.6

0.3

27.5

1.8

32.4

1268

500

20x2x1.5

0.6

0.4

31.3

2.0

37.1

1670

500

24x2x1.5

0.6

0.4

34.9

2.1

40.9

1919

500

30x2x1.5

0.6

0.4

37.1

2.2

43.3

2273

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

IEC 60092-376

Sheath thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.6

0.2

9.7

1.2

13.0

224

1000

2x2x2.5

0.6

0.3

14.4

1.4

18.5

418

1000

3x2x2.5

0.6

0.3

15.4

1.4

19.5

507

1000

4x2x2.5

0.6

0.3

16.9

1.5

21.3

598

1000

5x2x2.5

0.6

0.3

18.6

1.5

23.0

701

1000

6x2x2.5

0.6

0.3

20.4

1.6

25.0

798

500

7x2x2.5

0.6

0.3

20.4

1.6

25.0

860

500

10x2x2.5

0.6

0.3

26.5

1.8

31.4

1196

500

12x2x2.5

0.6

0.3

27.5

1.8

32.4

1334

500

16x2x2.5

0.6

0.4

31.1

2.0

36.9

1812

500

20x2x2.5

0.6

0.4

34.9

2.1

40.9

2144

500

24x2x2.5

0.6

0.4

39.0

2.3

45.4

2544

500

30x2x2.5

0.6

0.4

41.5

2.4

48.1

3027

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

87

RE-2X(St)YQY

IEC 60092-376

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

KCI

150/250 V (300 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Braid of Galvanized Steel Wires
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

IEC 60331

Instrument Cables

Criteria

88

Conductor cross section

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.4

0.2

7.0

1.1

10.1

149

1000

2x3x0.5

0.4

0.3

10.4

1.2

14.2

252

1000

3x3x0.5

0.4

0.3

11.1

1.3

15.0

306

1000

4x3x0.5

0.4

0.3

12.1

1.3

16.1

343

1000

5x3x0.5

0.4

0.3

13.3

1.3

17.2

382

1000

6x3x0.5

0.4

0.3

14.5

1.4

18.7

445

1000

7x3x0.5

0.4

0.3

14.5

1.4

18.7

470

1000

10x3x0.5

0.4

0.3

18.6

1.5

22.9

637

1000

12x3x0.5

0.4

0.3

19.2

1.5

23.6

694

1000

16x3x0.5

0.4

0.3

21.4

1.6

26.0

831

500

20x3x0.5

0.4

0.3

24.0

1.7

28.7

997

500

24x3x0.5

0.4

0.3

26.7

1.8

31.7

1167

500

30x3x0.5

0.4

0.3

28.4

1.8

33.3

1338

500

1x3x0.75

0.5

0.2

7.9

1.1

11.0

169

1000

2x3x0.75

0.5

0.3

12.0

1.3

15.9

314

1000

3x3x0.75

0.5

0.3

12.7

1.3

16.7

359

1000

4x3x0.75

0.5

0.3

14.0

1.4

18.1

433

1000

5x3x0.75

0.5

0.3

15.4

1.4

19.5

500

1000

6x3x0.75

0.5

0.3

16.8

1.5

21.2

562

1000

7x3x0.75

0.5

0.3

16.8

1.5

21.2

598

1000

10x3x0.75

0.5

0.3

21.6

1.6

26.2

797

500

12x3x0.75

0.5

0.3

22.4

1.7

27.2

910

500

16x3x0.75

0.5

0.3

25.0

1.7

29.8

1087

500

20x3x0.75

0.5

0.3

28.1

1.9

33.2

1322

500

24x3x0.75

0.5

0.4

31.7

2.0

37.5

1678

500

30x3x0.75

0.5

0.4

33.7

2.1

39.7

1941

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

89

KCI

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

IEC 60092-376

Sheath thickness

RE-2X(St)YQY

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.5

0.2

8.3

1.1

11.4

177

1000

2x3x1

0.5

0.3

12.6

1.3

16.6

334

1000

3x3x1

0.5

0.3

13.5

1.3

17.4

388

1000

4x3x1

0.5

0.3

14.8

1.4

19.0

473

1000

5x3x1

0.5

0.3

16.3

1.4

20.4

549

1000

6x3x1

0.5

0.3

17.8

1.5

22.2

622

1000

7x3x1

0.5

0.3

17.8

1.5

22.2

666

1000

10x3x1

0.5

0.3

23.0

1.7

27.7

929

500

12x3x1

0.5

0.3

23.8

1.7

28.6

1029

500

16x3x1

0.5

0.3

26.6

1.8

31.6

1279

500

20x3x1

0.5

0.3

29.9

1.9

35.0

1539

500

24x3x1

0.5

0.4

33.7

2.0

39.5

1916

500

30x3x1

0.5

0.4

35.9

2.1

41.9

2274

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

90

1x3x1.5

0.6

0.2

9.4

1.2

12.7

220

1000

2x3x1.5

0.6

0.3

14.5

1.4

18.7

421

1000

3x3x1.5

0.6

0.3

15.5

1.4

19.6

511

1000

4x3x1.5

0.6

0.3

17.1

1.5

21.4

604

1000

5x3x1.5

0.6

0.3

18.8

1.5

23.1

710

1000

6x3x1.5

0.6

0.3

20.6

1.6

25.2

808

500

7x3x1.5

0.6

0.3

20.6

1.6

25.2

872

500

10x3x1.5

0.6

0.3

26.7

1.8

31.7

1215

500

12x3x1.5

0.6

0.3

27.7

1.8

32.7

1357

500

16x3x1.5

0.6

0.4

31.4

2.0

37.2

1842

500

20x3x1.5

0.6

0.4

35.3

2.1

41.3

2182

500

24x3x1.5

0.6

0.4

39.3

2.3

45.7

2591

500

30x3x1.5

0.6

0.4

41.9

2.4

48.5

3084

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

IEC 60092-376

Sheath thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.6

0.2

10.3

1.2

13.6

268

1000

2x3x2.5

0.6

0.3

16.1

1.4

20.2

515

1000

3x3x2.5

0.6

0.3

17.2

1.5

21.5

632

1000

4x3x2.5

0.6

0.3

19.0

1.5

23.3

768

1000

5x3x2.5

0.6

0.3

20.9

1.6

25.5

897

500

6x3x2.5

0.6

0.3

23.0

1.7

27.7

1051

500

7x3x2.5

0.6

0.3

23.0

1.7

27.7

1144

500

10x3x2.5

0.6

0.3

29.9

1.9

35.0

1593

500

12x3x2.5

0.6

0.4

31.4

2.0

37.2

1940

500

16x3x2.5

0.6

0.4

35.1

2.1

41.1

2395

500

20x3x2.5

0.6

0.4

39.4

2.3

45.8

2926

500

24x3x2.5

0.6

0.4

44.5

2.5

51.3

3519

250

30x3x2.5

0.6

0.4

47.3

2.6

54.3

4163

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

91

KCI

RE-2X(St)YQY , PiMF
IEC 60092-376

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

150/250 V (300 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

92

IEC 60708 Full color

Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY , PiMF

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.4

0.2

7.0

1.1

10.1

158

1000

2x2x0.5

0.4

0.3

10.7

1.2

14.4

272

1000

3x2x0.5

0.4

0.3

11.4

1.3

15.3

333

1000

4x2x0.5

0.4

0.3

12.4

1.3

16.4

380

1000

5x2x0.5

0.4

0.3

13.6

1.3

17.6

442

1000

6x2x0.5

0.4

0.3

14.9

1.4

19.0

499

1000

7x2x0.5

0.4

0.3

14.9

1.4

19.0

532

1000

10x2x0.5

0.4

0.3

19.1

1.5

23.4

725

1000

12x2x0.5

0.4

0.3

19.7

1.6

24.3

810

1000

16x2x0.5

0.4

0.3

22.0

1.6

26.6

991

500

20x2x0.5

0.4

0.3

24.7

1.7

29.4

1169

500

24x2x0.5

0.4

0.3

27.5

1.8

32.4

1374

500

30x2x0.5

0.4

0.3

29.2

1.9

34.3

1632

500

1x2x0.75

0.5

0.2

7.8

1.1

10.9

174

1000

2x2x0.75

0.5

0.3

12.1

1.3

16.1

326

1000

3x2x0.75

0.5

0.3

12.9

1.3

16.9

377

1000

4x2x0.75

0.5

0.3

14.2

1.4

18.4

457

1000

5x2x0.75

0.5

0.3

15.6

1.4

19.7

529

1000

6x2x0.75

0.5

0.3

17.1

1.5

21.4

597

1000

7x2x0.75

0.5

0.3

17.1

1.5

21.4

638

1000

10x2x0.75

0.5

0.3

22.0

1.6

26.5

874

500

12x2x0.75

0.5

0.3

22.8

1.7

27.5

978

500

16x2x0.75

0.5

0.3

25.4

1.8

30.4

1211

500

20x2x0.75

0.5

0.3

28.5

1.9

33.7

1433

500

24x2x0.75

0.5

0.4

32.2

2.0

38.0

1812

500

30x2x0.75

0.5

0.4

34.3

2.1

40.3

2107

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

93

KCI

RE-2X(St)YQY , PiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.5

0.2

8.2

1.1

11.3

173

1000

2x2x1

0.5

0.3

12.8

1.3

16.7

329

1000

3x2x1

0.5

0.3

13.6

1.3

17.6

396

1000

4x2x1

0.5

0.3

15.0

1.4

19.1

457

1000

5x2x1

0.5

0.3

16.4

1.4

20.6

535

1000

6x2x1

0.5

0.3

18.0

1.5

22.4

605

1000

7x2x1

0.5

0.3

18.0

1.5

22.4

646

1000

10x2x1

0.5

0.3

23.3

1.7

28.0

901

500

12x2x1

0.5

0.3

24.1

1.7

28.9

995

500

16x2x1

0.5

0.3

26.9

1.8

31.9

1233

500

20x2x1

0.5

0.3

30.2

1.9

35.4

1481

500

24x2x1

0.5

0.4

34.2

2.1

40.2

1865

500

30x2x1

0.5

0.4

36.3

2.1

42.3

2187

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

94

1x2x1.5

0.6

0.2

9.2

1.2

12.5

209

1000

2x2x1.5

0.6

0.3

14.6

1.4

18.7

404

1000

3x2x1.5

0.6

0.3

15.5

1.4

19.7

485

1000

4x2x1.5

0.6

0.3

17.1

1.5

21.5

569

1000

5x2x1.5

0.6

0.3

18.9

1.5

23.2

665

1000

6x2x1.5

0.6

0.3

20.7

1.6

25.2

755

500

7x2x1.5

0.6

0.3

20.7

1.6

25.2

810

500

10x2x1.5

0.6

0.3

26.8

1.8

31.8

1126

500

12x2x1.5

0.6

0.3

27.8

1.8

32.8

1250

500

16x2x1.5

0.6

0.4

31.5

2.0

37.3

1700

500

20x2x1.5

0.6

0.4

35.4

2.1

41.4

2004

500

24x2x1.5

0.6

0.4

39.5

2.3

45.9

2378

500

30x2x1.5

0.6

0.4

42.0

2.4

48.6

2818

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

IEC 60092-376

Sheath thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY , PiMF

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.6

0.2

10.0

1.2

13.3

250

1000

2x2x2.5

0.6

0.3

16.0

1.4

20.2

484

1000

3x2x2.5

0.6

0.3

17.2

1.5

21.5

584

1000

4x2x2.5

0.6

0.3

18.9

1.5

23.3

705

1000

5x2x2.5

0.6

0.3

20.9

1.6

25.4

818

500

6x2x2.5

0.6

0.3

22.9

1.7

27.7

956

500

7x2x2.5

0.6

0.3

22.9

1.7

27.7

1034

500

10x2x2.5

0.6

0.3

29.8

1.9

35.0

1435

500

12x2x2.5

0.6

0.4

31.3

2.0

37.1

1751

500

16x2x2.5

0.6

0.4

35.0

2.1

41.0

2143

500

20x2x2.5

0.6

0.4

39.4

2.3

45.8

2611

500

24x2x2.5

0.6

0.4

44.4

2.5

51.2

3142

250

30x2x2.5

0.6

0.4

47.2

2.6

54.2

3692

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

95

KCI

RE-2X(St)YQY , TiMF
IEC 60092-376

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

150/250 V (300 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

96

Conductor cross section

Mica-glass Tape + XLPE


Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria

Blue,White,Red (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

40.4

26

19.2

12.8

7.86

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 5
minutes

1.5 kV A.C

K.V

300

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY , TiMF

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.4

0.2

7.4

1.1

10.5

170

1000

2x3x0.5

0.4

0.3

11.8

1.3

15.8

323

1000

3x3x0.5

0.4

0.3

12.6

1.3

16.5

374

1000

4x3x0.5

0.4

0.3

13.8

1.3

17.8

445

1000

5x3x0.5

0.4

0.3

15.1

1.4

19.3

506

1000

6x3x0.5

0.4

0.3

16.6

1.4

20.7

584

1000

7x3x0.5

0.4

0.3

16.6

1.4

20.7

625

1000

10x3x0.5

0.4

0.3

21.3

1.6

25.9

850

500

12x3x0.5

0.4

0.3

22.1

1.6

26.6

962

500

16x3x0.5

0.4

0.3

24.7

1.7

29.4

1174

500

20x3x0.5

0.4

0.3

27.7

1.8

32.6

1415

500

24x3x0.5

0.4

0.3

30.8

1.9

36.0

1663

500

30x3x0.5

0.4

0.4

33.2

2.0

39.0

2086

500

1x3x0.75

0.5

0.2

8.2

1.1

11.3

191

1000

2x3x0.75

0.5

0.3

13.5

1.3

17.4

367

1000

3x3x0.75

0.5

0.3

14.4

1.4

18.5

455

1000

4x3x0.75

0.5

0.3

15.8

1.4

20.0

540

1000

5x3x0.75

0.5

0.3

17.4

1.5

21.7

621

1000

6x3x0.75

0.5

0.3

19.1

1.5

23.4

715

1000

7x3x0.75

0.5

0.3

19.1

1.5

23.4

768

1000

10x3x0.75

0.5

0.3

24.7

1.7

29.4

1043

500

12x3x0.75

0.5

0.3

25.5

1.8

30.5

1196

500

16x3x0.75

0.5

0.3

28.6

1.9

33.7

1465

500

20x3x0.75

0.5

0.4

32.5

2.0

38.3

1896

500

24x3x0.75

0.5

0.4

36.2

2.2

42.4

2248

500

30x3x0.75

0.5

0.4

38.5

2.2

44.7

2605

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

97

KCI

RE-2X(St)YQY , TiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Diameter Under
Armour

150/250 V (300 V)

Armour Wire
Diameter

IEC 60092-376
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.5

0.2

8.6

1.2

11.9

204

1000

2x3x1

0.5

0.3

14.2

1.4

18.4

401

1000

3x3x1

0.5

0.3

15.2

1.4

19.3

463

1000

4x3x1

0.5

0.3

16.7

1.4

20.9

558

1000

5x3x1

0.5

0.3

18.4

1.5

22.7

644

1000

6x3x1

0.5

0.3

20.2

1.6

24.7

754

500

7x3x1

0.5

0.3

20.2

1.6

24.7

810

500

10x3x1

0.5

0.3

26.1

1.8

31.1

1126

500

12x3x1

0.5

0.3

27.1

1.8

32.0

1251

500

16x3x1

0.5

0.3

30.3

1.9

35.4

1559

500

20x3x1

0.5

0.4

34.4

2.1

40.4

2007

500

24x3x1

0.5

0.4

38.4

2.2

44.6

2361

500

30x3x1

0.5

0.4

40.9

2.3

47.3

2763

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

98

1x3x1.5

0.6

0.2

9.7

1.2

13.0

237

1000

2x3x1.5

0.6

0.3

16.2

1.4

20.4

482

1000

3x3x1.5

0.6

0.3

17.3

1.5

21.7

582

1000

4x3x1.5

0.6

0.3

19.2

1.5

23.5

701

1000

5x3x1.5

0.6

0.3

21.1

1.6

25.7

814

500

6x3x1.5

0.6

0.3

23.2

1.7

27.9

952

500

7x3x1.5

0.6

0.3

23.2

1.7

27.9

1028

500

10x3x1.5

0.6

0.3

30.2

1.9

35.3

1429

500

12x3x1.5

0.6

0.4

31.7

2.0

37.5

1744

500

16x3x1.5

0.6

0.4

35.4

2.1

41.4

2133

500

20x3x1.5

0.6

0.4

39.8

2.3

46.2

2599

500

24x3x1.5

0.6

0.4

44.9

2.5

51.7

3128

250

30x3x1.5

0.6

0.4

47.8

2.6

54.8

3694

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

mm

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm2

Overall
Diameter

Nominal cross section


area of conductor

Armour Wire
Diameter

150/250 V (300 V)

Insulation
thickness

IEC 60092-376

Sheath thickness

Fire Resistant

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YQY , TiMF

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.6

0.3

10.6

1.3

14.6

318

1000

2x3x2.5

0.6

0.3

17.9

1.5

22.3

580

1000

3x3x2.5

0.6

0.3

19.2

1.6

23.7

736

1000

4x3x2.5

0.6

0.3

21.2

1.6

25.8

871

500

5x3x2.5

0.6

0.3

23.4

1.7

28.2

1043

500

6x3x2.5

0.6

0.3

25.8

1.8

30.7

1219

500

7x3x2.5

0.6

0.3

25.8

1.8

30.7

1328

500

10x3x2.5

0.6

0.4

34.0

2.1

40.0

1975

500

12x3x2.5

0.6

0.4

35.2

2.1

41.2

2215

500

16x3x2.5

0.6

0.4

39.5

2.3

45.9

2807

500

20x3x2.5

0.6

0.4

44.8

2.5

51.6

3471

250

24x3x2.5

0.6

0.4

50.0

2.7

57.2

4092

250

30x3x2.5

0.6

0.4

53.2

2.8

60.6

7685

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HQH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

99

Kerman & Kavian Cable Industries ( KCI )

KCI

Multi-element metallic cables used in analogue and


digital communication and control
According to EN 50288-7 (2005)
Part 7: Sectional specification for instrumentation and
control cables

Kerman & Kavian Cable Industries ( KCI )

A Summary of EN 50288-7 (2005)


Multi-element metallic cables used in analogue and
digital communication and control
Part 7: Sectional specification for instrumentation and control cables

KCI

Scope :
This sectional specification covers multi-element cables suitable for connecting instruments and control
systems for analogue or digital signal transmission.
They may or may not be screened and optionally may incorporate armouring and/or moisture or
environmental protection layers.
The cables shall have a mechanically robust construction and electrical transmission handling properties.
The electrical, mechanical, transmission and environmental performance characteristics of the cables, related
to their reference test methods are detailed .
Cables covered by this specification have maximum rated voltages of 90 V, 300 V and 500 V a.c.
These cables shall not be connected directly to mains electricity supply or other low impedance sources.
Multi-element cables for use in analogue,
digital and control circuits are not designed to be used for power supply.
1) Conductor
Conductors shall be solid, stranded or flexible plain or metal coated copper in accordance with Class 1, 2 or 5
of HD 383 ( equal to IEC 60228) in the range of 0.5 mm2 to 2.5 mm2 .
For multi-core cables the maximum conductor resistance shall be as HD 383 ( equal to IEC 60228) , and for
finished multi-pair, multi- triple and multi-quad cables the maximum resistance of HD 383 shall be increased
by 2 %.

Instrument Cables

Conductor joints shall be as EN 50288-1 (IEC 60228) .


Stranded and flexible conductors shall consist of wires circular in cross section assembled, without insulation
between them, by concentric stranding or by bunching.

102

When the installed length of cable results in a high conductor resistance,


larger conductor sizes can be used.

The values are extracted from DIN VDE 0295 (equivalent with the international standard IEC 60228 and HD 383),
according to cross-sections and conductor classes, beginning with nominal cross-section of 0.5 mm2 .

Nominal
cross-section
mm2
0.5
0.75
1.0
1.5
2.5

Copper conductor plain wires


(Ohm/km)
class 1 and 2
Class 5
36.0
39.0
24.5
26.0
18.1
19.5
12.1
13.3
7.41
7.98

Copper conductor tinned wires


(Ohm/km)
Class 1 and 2
Class 5
36.7
40.1
24.8
26.7
18.2
20.0
12.2
13.7
7.56
8.21

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

a) PVC
b) Polyethylene
c) Polypropylene
d) Halogen free F.R
e) Cross-linked polyethylene

EN 50290-2-21
EN 50290-2-23
EN 50290-2-25
EN 50290-2-26
EN 50290-2-29

Kerman & Kavian Cable Industries ( KCI )

KCI

2 ) Insulation
The insulating material shall be selected from those
listed below.

A Conductor Insulated by Mica-glass and


an extruded Insulation Used as insulation
of Fire-Resistance Cables

The minimum thickness at any point of the insulation


shall not be less than the value given in following Table
XLPE : Cross-linked Polyethylene

Minimum thickness mm
Conductor size
Voltage rating
2

mm
0.5
0.75
1.0
1.5
2.5

90 V
0.2
0.2
0.26
0.3
-

300 V
0.26
0.26
0.26
0.35
-

500 V
0.44
0.44
0.44
0.44
0.53

PVC : Poly vinyl chloride

3 ) Cable elements
The cable element is:
a single insulated wire, or
a pair consisting of two insulated conductors twisted together and designated wire a and wire b, or
a triple consisting of three insulated conductors twisted together and
designated wire a, wire b and wire c in order of rotation, or
a quad consisting of four insulated conductors twisted together and designated wire a, wire c,
wire b and wire d in order of rotation.
Wires a and b form pair 1 and wires c and d form pair 2.

Instrument Cables

The lay length of a pair, triple or quad shall not exceed 100 mm for cables with conductor
cross- sections 1.5 mm2, nor 150 mm for cables with conductor cross-section 2.5 mm2.

Core (Unit)

Pair (Unit)

Triple (Unit)

103

3-1 ) Identification of cabling elements


Unless otherwise specified e.g. by means of numbered cores or tapes, the coding for identification shall
be as given in IEC 60189-2 or EN 60708 (IEC 60708), as appropriate.

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

KCI

Kerman & Kavian Cable Industries ( KCI )

5 ) Screening of cabling elements


When screening of individual cable elements is specified (or in relevant sectional specification ) , it shall be
selected from those listed one or any combination of the following :
5-1 ) a plain or coated metal braid
5-2 ) a combination of a foil, and a plain or coated metal braid .
The use of a drain wire is optional when this type of screen is applied;
5-3 ) a foil applied with a minimum overlap of 20 % and with a drain wire in direct contact with the
metallic side of the foil.
If a drain wire is incorporated it shall be in contact with the main screen element.
The drain wire is either solid or stranded made of plain or metal coated copper wire.
Care should be taken when putting dissimilar metals in contact with each other.
Coatings or other methods of protection may be necessary to prevent galvanic interaction.

Plain Copper wires


Braid

Tinned Plain Copper


wires Braid

Pair (Unit) Individually Screened


in Metallic Foil (PiMF)

Static Tape (Screen)

Tinned Plain Copper


wires Braid + Al.Foil

Triple (Unit) Individually Screened


in Metallic Foil (TiMF)

Instrument Cables

*** Optional : additional individual sheath over each screened element (ref. to other specs)

104

Pair (Unit) Individually Screened


in Metallic Foil and sheathed(PiMFY)

Triple (Unit) Individually Screened


in Metallic Foil and sheathed(TiMFY)

6 ) Screening of the cable core


The cable core shall be protected with a protective layer , when it is covered with a screen.
When screening of the cable core is specified, it shall be selected from those listed in above section .
Screening over the cable core may also be in the form of a laminated sheath .

Laminated Sheath

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

Lead Sheath (Lead Cover)

Kerman & Kavian Cable Industries ( KCI )

7 ) Chemical and /or environmental protection


When chemical or environmental protection is required, one of the following methods shall be used.
7-1 ) Lead Sheath
7-2) Multi layer sheath (comprise a laminated sheath and an additional layer of polyamide)

Multi-layer sheath :
Aluminium copolymer bonded to
HDPE sheath + Polyamide layer

8 ) Metallic protection
When required by the relevant sectional specification the armouring shall consist of
one or more of the following:
8-1) layer of round or flat galvanised steel wires;
8-2) single or a double layer of steel or brass tapes;
8-3) galvanized steel or tinned copper wire braid.

Tape Armour

Braid Armour

9 ) Outer sheathing
The outer sheathing material shall be appropriate to the operating environment and may be
selected from the materials listed below :
a) PVC
EN 50290-2-22
b) Polyethylene
EN 50290-2-24
c) Halogen free F.R
EN 50290-2-27

10 ) Fauna proofing (Anti-Termite and/or Anti-Rodent)


The relevant sectional specification shall indicate details of the fauna proofing required to protect the cable
against attack by fauna (such as rodents or termite).
The protection may be a choice of armouring , special wrapping tape ,a choice of outer sheath material or
any combination of these.

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Wire Armour

105

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-Y(St)Y

EN 50288-7 (500 V)

RE-Y(St)Y Multi-Core
RE-Y(St)Y Multi-Pair
RE-Y(St)Y Multi-Triple
RE-Y(St)Y PiMF
RE-Y(St)Y TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-Y(St)Y
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+70 oC

Instrument Cables

108

PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.3 mm)


2x0.5

0.6

0.9

6.3

44

1000

3x0.5

0.6

0.9

6.6

54

1000

4x0.5

0.6

0.9

7.2

65

1000

5x0.5

0.6

0.9

7.8

76

1000

6x0.5

0.6

0.9

8.4

87

1000

7x0.5

0.6

0.9

8.4

96

1000

8x0.5

0.6

1.0

9.8

113

1000

10x0.5

0.6

1.0

10.7

134

1000

12x0.5

0.6

1.0

11.0

153

1000

16x0.5

0.6

1.0

12.2

193

1000

20x0.5

0.6

1.1

13.7

238

1000

24x0.5

0.6

1.1

15.1

280

1000

30x0.5

0.6

1.2

16.1

342

1000

2x0.75

0.6

0.9

6.7

52

1000

3x0.75

0.6

0.9

7.1

65

1000

4x0.75

0.6

0.9

7.7

79

1000

5x0.75

0.6

0.9

8.3

93

1000

6x0.75

0.6

0.9

9.0

108

1000

7x0.75

0.6

0.9

9.0

120

1000

8x0.75

0.6

1.0

10.6

141

1000

10x0.75

0.6

1.0

11.5

168

1000

12x0.75

0.6

1.0

11.9

193

1000

16x0.75

0.6

1.1

13.3

251

1000

20x0.75

0.6

1.1

14.8

305

1000

24x0.75

0.6

1.2

16.5

365

1000

30x0.75

0.6

1.2

17.5

440

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

109

KCI

RE-Y(St)Y

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.9

7.1

59

1000

3x1

0.6

0.9

7.5

75

1000

4x1

0.6

0.9

8.1

92

1000

5x1

0.6

0.9

8.8

110

1000

6x1

0.6

1.0

9.8

131

1000

7x1

0.6

1.0

9.8

146

1000

8x1

0.6

1.0

11.3

167

1000

10x1

0.6

1.0

12.2

200

1000

12x1

0.6

1.0

12.6

232

1000

16x1

0.6

1.1

14.2

302

1000

20x1

0.6

1.1

15.8

368

1000

24x1

0.6

1.2

17.6

441

1000

30x1

0.6

1.2

18.6

534

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

110

2x1.5

0.6

0.9

7.7

73

1000

3x1.5

0.6

0.9

8.1

96

1000

4x1.5

0.6

0.9

8.8

119

1000

5x1.5

0.6

1.0

9.8

146

1000

6x1.5

0.6

1.0

10.7

171

1000

7x1.5

0.6

1.0

10.7

191

1000

8x1.5

0.6

1.0

12.3

219

1000

10x1.5

0.6

1.1

13.6

270

1000

12x1.5

0.6

1.1

14.1

313

1000

16x1.5

0.6

1.1

15.6

402

1000

20x1.5

0.6

1.2

17.6

499

1000

24x1.5

0.6

1.3

19.6

599

1000

30x1.5

0.6

1.3

20.8

728

1000

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

0.9

8.9

102

1000

3x2.5

0.7

1.0

9.7

140

1000

4x2.5

0.7

1.0

10.5

175

1000

5x2.5

0.7

1.0

11.5

211

1000

6x2.5

0.7

1.1

12.7

253

1000

7x2.5

0.7

1.1

12.7

285

1000

8x2.5

0.7

1.1

14.8

326

1000

10x2.5

0.7

1.2

16.3

403

1000

12x2.5

0.7

1.2

16.9

470

1000

16x2.5

0.7

1.3

18.9

615

1000

20x2.5

0.7

1.3

21.1

754

1000

24x2.5

0.7

1.4

23.5

904

1000

30x2.5

0.7

1.5

25.1

1113

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

111

KCI

RE-Y(St)Y
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+70 oC

IEC 60332-1

Instrument Cables

Criteria

112

Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.6

0.9

6.3

44

1000

2x2x0.5

0.6

0.9

9.0

73

1000

3x2x0.5

0.6

1.0

9.7

96

1000

4x2x0.5

0.6

1.0

10.6

118

1000

5x2x0.5

0.6

1.0

11.6

140

1000

6x2x0.5

0.6

1.1

12.8

167

1000

7x2x0.5

0.6

1.1

12.8

185

1000

10x2x0.5

0.6

1.2

16.5

260

1000

12x2x0.5

0.6

1.2

17.0

298

1000

16x2x0.5

0.6

1.2

18.9

379

1000

20x2x0.5

0.6

1.3

21.2

469

1000

24x2x0.5

0.6

1.4

23.8

561

1000

30x2x0.5

0.6

1.4

25.2

676

500

1x2x0.75

0.6

0.9

6.7

52

1000

2x2x0.75

0.6

1.0

9.9

92

1000

3x2x0.75

0.6

1.0

10.5

118

1000

4x2x0.75

0.6

1.0

11.5

146

1000

5x2x0.75

0.6

1.1

12.7

180

1000

6x2x0.75

0.6

1.1

13.9

209

1000

7x2x0.75

0.6

1.1

13.9

233

1000

10x2x0.75

0.6

1.2

17.8

329

1000

12x2x0.75

0.6

1.2

18.4

380

1000

16x2x0.75

0.6

1.3

20.7

494

1000

20x2x0.75

0.6

1.4

23.3

612

1000

24x2x0.75

0.6

1.5

26.0

732

500

30x2x0.75

0.6

1.5

27.6

886

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

113

KCI

RE-Y(St)Y

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

7.1

59

1000

2x2x1

0.6

1.0

10.5

106

1000

3x2x1

0.6

1.0

11.1

139

1000

4x2x1

0.6

1.0

12.2

173

1000

5x2x1

0.6

1.1

13.5

213

1000

6x2x1

0.6

1.1

14.7

249

1000

7x2x1

0.6

1.1

14.7

279

1000

10x2x1

0.6

1.2

19.0

395

1000

12x2x1

0.6

1.3

19.9

465

1000

16x2x1

0.6

1.3

22.1

597

1000

20x2x1

0.6

1.4

24.9

740

500

24x2x1

0.6

1.5

27.8

886

500

30x2x1

0.6

1.6

29.7

1088

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

114

1x2x1.5

0.6

0.9

7.7

74

1000

2x2x1.5

0.6

1.0

11.4

135

1000

3x2x1.5

0.6

1.0

12.2

180

1000

4x2x1.5

0.6

1.1

13.6

232

1000

5x2x1.5

0.6

1.1

14.8

280

1000

6x2x1.5

0.6

1.2

16.4

334

1000

7x2x1.5

0.6

1.2

16.4

376

1000

10x2x1.5

0.6

1.3

21.2

533

1000

12x2x1.5

0.6

1.3

21.9

621

1000

16x2x1.5

0.6

1.4

24.6

811

500

20x2x1.5

0.6

1.5

27.7

1006

500

24x2x1.5

0.6

1.6

30.9

1205

500

30x2x1.5

0.6

1.7

33.0

1481

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

8.9

103

1000

2x2x2.5

0.7

1.1

13.7

196

1000

3x2x2.5

0.7

1.1

14.6

266

1000

4x2x2.5

0.7

1.2

16.2

344

1000

5x2x2.5

0.7

1.2

17.8

417

1000

6x2x2.5

0.7

1.3

19.7

499

1000

7x2x2.5

0.7

1.3

19.7

564

1000

10x2x2.5

0.7

1.5

25.7

810

500

12x2x2.5

0.7

1.5

26.6

946

500

16x2x2.5

0.7

1.6

29.8

1237

500

20x2x2.5

0.7

1.7

33.5

1534

500

24x2x2.5

0.7

1.8

37.4

1836

500

30x2x2.5

0.7

1.9

39.9

2259

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

115

KCI

RE-Y(St)Y
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Outer Sheath
Extruded PVC

+70 oC

IEC 60332-1

Instrument Cables

Criteria

116

Conductor cross section

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.6

0.9

6.6

55

1000

2x3x0.5

0.6

1.0

10.1

98

1000

3x3x0.5

0.6

1.0

10.8

127

1000

4x3x0.5

0.6

1.0

11.8

158

1000

5x3x0.5

0.6

1.1

13.1

195

1000

6x3x0.5

0.6

1.1

14.3

227

1000

7x3x0.5

0.6

1.1

14.3

253

1000

10x3x0.5

0.6

1.2

18.4

359

1000

12x3x0.5

0.6

1.2

19.0

415

1000

16x3x0.5

0.6

1.3

21.3

541

1000

20x3x0.5

0.6

1.4

24.0

670

1000

24x3x0.5

0.6

1.5

26.8

802

500

30x3x0.5

0.6

1.5

28.4

971

500

1x3x0.75

0.6

0.9

7.1

66

1000

2x3x0.75

0.6

1.0

10.9

120

1000

3x3x0.75

0.6

1.0

11.6

159

1000

4x3x0.75

0.6

1.1

12.9

205

1000

5x3x0.75

0.6

1.1

14.1

246

1000

6x3x0.75

0.6

1.1

15.4

288

1000

7x3x0.75

0.6

1.1

15.4

324

1000

10x3x0.75

0.6

1.3

20.2

468

1000

12x3x0.75

0.6

1.3

20.8

543

1000

16x3x0.75

0.6

1.4

23.4

708

1000

20x3x0.75

0.6

1.5

26.3

878

500

24x3x0.75

0.6

1.6

29.4

1050

500

30x3x0.75

0.6

1.6

31.2

1277

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

117

KCI

RE-Y(St)Y

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

7.5

76

1000

2x3x1

0.6

1.0

11.6

141

1000

3x3x1

0.6

1.0

12.3

189

1000

4x3x1

0.6

1.1

13.7

244

1000

5x3x1

0.6

1.1

15.0

295

1000

6x3x1

0.6

1.2

16.6

353

1000

7x3x1

0.6

1.2

16.6

398

1000

10x3x1

0.6

1.3

21.5

564

1000

12x3x1

0.6

1.3

22.2

658

1000

16x3x1

0.6

1.4

25.0

861

500

20x3x1

0.6

1.5

28.1

1068

500

24x3x1

0.6

1.6

31.4

1279

500

30x3x1

0.6

1.7

33.5

1574

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

118

1x3x1.5

0.6

0.9

8.1

97

1000

2x3x1.5

0.6

1.1

12.9

187

1000

3x3x1.5

0.6

1.1

13.7

254

1000

4x3x1.5

0.6

1.1

15.1

323

1000

5x3x1.5

0.6

1.2

16.8

399

1000

6x3x1.5

0.6

1.2

18.3

470

1000

7x3x1.5

0.6

1.2

18.3

532

1000

10x3x1.5

0.6

1.4

23.9

766

1000

12x3x1.5

0.6

1.4

24.8

896

500

16x3x1.5

0.6

1.5

27.8

1174

500

20x3x1.5

0.6

1.6

31.3

1458

500

24x3x1.5

0.6

1.7

35.0

1746

500

30x3x1.5

0.6

1.8

37.3

2152

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

9.7

141

1000

2x3x2.5

0.7

1.1

15.2

269

1000

3x3x2.5

0.7

1.2

16.4

378

1000

4x3x2.5

0.7

1.2

18.1

484

1000

5x3x2.5

0.7

1.3

20.1

599

1000

6x3x2.5

0.7

1.4

22.2

716

1000

7x3x2.5

0.7

1.4

22.2

813

1000

10x3x2.5

0.7

1.6

29.0

1167

500

12x3x2.5

0.7

1.6

30.0

1369

500

16x3x2.5

0.7

1.7

33.6

1795

500

20x3x2.5

0.7

1.9

38.0

2244

500

24x3x2.5

0.7

2.0

42.5

2685

500

30x3x2.5

0.7

2.1

45.3

3310

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

119

KCI

RE-Y(St)Y , PiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+70 oC

IEC 60332-1

Instrument Cables

Criteria

120

Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.6

0.9

6.6

54

1000

2x2x0.5

0.6

1.0

10.4

98

1000

3x2x0.5

0.6

1.0

11.0

126

1000

4x2x0.5

0.6

1.0

12.1

156

1000

5x2x0.5

0.6

1.1

13.4

192

1000

6x2x0.5

0.6

1.1

14.6

224

1000

7x2x0.5

0.6

1.1

14.6

250

1000

10x2x0.5

0.6

1.2

18.9

353

1000

12x2x0.5

0.6

1.3

19.8

416

1000

16x2x0.5

0.6

1.3

21.9

531

1000

20x2x0.5

0.6

1.4

24.7

657

500

24x2x0.5

0.6

1.5

27.6

787

500

30x2x0.5

0.6

1.6

29.5

963

500

1x2x0.75

0.6

0.9

7.1

62

1000

2x2x0.75

0.6

1.0

11.1

114

1000

3x2x0.75

0.6

1.0

11.9

149

1000

4x2x0.75

0.6

1.1

13.2

192

1000

5x2x0.75

0.6

1.1

14.4

230

1000

6x2x0.75

0.6

1.2

16.0

275

1000

7x2x0.75

0.6

1.2

16.0

307

1000

10x2x0.75

0.6

1.3

20.6

435

1000

12x2x0.75

0.6

1.3

21.3

503

1000

16x2x0.75

0.6

1.4

23.9

655

1000

20x2x0.75

0.6

1.5

26.9

810

500

24x2x0.75

0.6

1.6

30.1

970

500

30x2x0.75

0.6

1.6

31.9

1176

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

121

KCI

RE-Y(St)Y , PiMF

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

7.4

70

1000

2x2x1

0.6

1.0

11.8

129

1000

3x2x1

0.6

1.0

12.5

171

1000

4x2x1

0.6

1.1

14.0

220

1000

5x2x1

0.6

1.1

15.3

265

1000

6x2x1

0.6

1.2

16.9

317

1000

7x2x1

0.6

1.2

16.9

355

1000

10x2x1

0.6

1.3

21.9

503

1000

12x2x1

0.6

1.4

22.8

593

1000

16x2x1

0.6

1.4

25.4

763

500

20x2x1

0.6

1.5

28.6

945

500

24x2x1

0.6

1.6

32.0

1132

500

30x2x1

0.6

1.7

34.1

1389

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

122

1x2x1.5

0.6

0.9

8.0

85

1000

2x2x1.5

0.6

1.1

13.0

164

1000

3x2x1.5

0.6

1.1

13.9

219

1000

4x2x1.5

0.6

1.1

15.3

277

1000

5x2x1.5

0.6

1.2

16.9

341

1000

6x2x1.5

0.6

1.2

18.5

400

1000

7x2x1.5

0.6

1.2

18.5

451

1000

10x2x1.5

0.6

1.4

24.2

650

1000

12x2x1.5

0.6

1.4

25.1

757

500

16x2x1.5

0.6

1.5

28.1

988

500

20x2x1.5

0.6

1.6

31.6

1225

500

24x2x1.5

0.6

1.8

35.6

1480

500

30x2x1.5

0.6

1.8

37.7

1802

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.0

9.5

118

1000

2x2x2.5

0.7

1.1

15.3

224

1000

3x2x2.5

0.7

1.2

16.5

311

1000

4x2x2.5

0.7

1.2

18.1

395

1000

5x2x2.5

0.7

1.3

20.1

487

1000

6x2x2.5

0.7

1.4

22.2

582

1000

7x2x2.5

0.7

1.4

22.2

657

1000

10x2x2.5

0.7

1.6

29.0

943

500

12x2x2.5

0.7

1.6

30.0

1101

500

16x2x2.5

0.7

1.7

33.7

1438

500

20x2x2.5

0.7

1.9

38.1

1797

500

24x2x2.5

0.7

2.0

42.6

2148

500

30x2x2.5

0.7

2.1

45.4

2639

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

123

KCI

RE-Y(St)Y , TiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+70 oC

Instrument Cables

124

Conductor cross section

PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

7.5x O.D

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.6

0.9

7.0

64

1000

2x3x0.5

0.6

1.0

11.5

120

1000

3x3x0.5

0.6

1.0

12.2

159

1000

4x3x0.5

0.6

1.1

13.6

204

1000

5x3x0.5

0.6

1.1

14.9

245

1000

6x3x0.5

0.6

1.2

16.5

293

1000

7x3x0.5

0.6

1.2

16.5

328

1000

10x3x0.5

0.6

1.3

21.3

464

1000

12x3x0.5

0.6

1.3

22.0

538

1000

16x3x0.5

0.6

1.4

24.7

701

500

20x3x0.5

0.6

1.5

27.8

868

500

24x3x0.5

0.6

1.6

31.1

1038

500

30x3x0.5

0.6

1.7

33.2

1273

500

1x3x0.75

0.6

0.9

7.4

76

1000

2x3x0.75

0.6

1.0

12.3

144

1000

3x3x0.75

0.6

1.1

13.3

197

1000

4x3x0.75

0.6

1.1

14.6

248

1000

5x3x0.75

0.6

1.2

16.3

305

1000

6x3x0.75

0.6

1.2

17.8

357

1000

7x3x0.75

0.6

1.2

17.8

402

1000

10x3x0.75

0.6

1.4

23.2

579

1000

12x3x0.75

0.6

1.4

24.0

673

1000

16x3x0.75

0.6

1.5

26.9

877

500

20x3x0.75

0.6

1.6

30.3

1087

500

24x3x0.75

0.6

1.7

33.8

1300

500

30x3x0.75

0.6

1.8

36.1

1596

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

125

KCI

RE-Y(St)Y , TiMF

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

7.8

86

1000

2x3x1

0.6

1.1

13.3

170

1000

3x3x1

0.6

1.1

14.1

228

1000

4x3x1

0.6

1.1

15.5

288

1000

5x3x1

0.6

1.2

17.2

356

1000

6x3x1

0.6

1.2

18.9

418

1000

7x3x1

0.6

1.2

18.9

472

1000

10x3x1

0.6

1.4

24.6

679

500

12x3x1

0.6

1.4

25.5

792

500

16x3x1

0.6

1.5

28.6

1036

500

20x3x1

0.6

1.6

32.2

1285

500

24x3x1

0.6

1.8

36.2

1551

500

30x3x1

0.6

1.8

38.4

1891

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

126

1x3x1.5

0.6

0.9

8.5

108

1000

2x3x1.5

0.6

1.1

14.5

213

1000

3x3x1.5

0.6

1.1

15.4

290

1000

4x3x1.5

0.6

1.2

17.2

377

1000

5x3x1.5

0.6

1.2

18.9

457

1000

6x3x1.5

0.6

1.3

20.9

547

1000

7x3x1.5

0.6

1.3

20.9

619

1000

10x3x1.5

0.6

1.5

27.3

890

500

12x3x1.5

0.6

1.5

28.2

1040

500

16x3x1.5

0.6

1.6

31.7

1362

500

20x3x1.5

0.6

1.8

35.9

1704

500

24x3x1.5

0.6

1.9

40.1

2038

500

30x3x1.5

0.6

2.0

42.7

2507

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)Y , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Sheath thickness

mm2

Overall
Diameter

Nominal cross section area of


conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

10.0

154

1000

2x3x2.5

0.7

1.2

17.2

305

1000

3x3x2.5

0.7

1.2

18.4

419

1000

4x3x2.5

0.7

1.3

20.4

545

1000

5x3x2.5

0.7

1.4

22.7

674

1000

6x3x2.5

0.7

1.4

24.9

795

500

7x3x2.5

0.7

1.4

24.9

903

500

10x3x2.5

0.7

1.7

32.7

1309

500

12x3x2.5

0.7

1.7

33.9

1534

500

16x3x2.5

0.7

1.9

38.2

2024

500

20x3x2.5

0.7

2.0

43.0

2510

500

24x3x2.5

0.7

2.2

48.2

3020

500

30x3x2.5

0.7

2.3

51.4

3717

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

127

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)Y

Fire Resistant

EN 50288-7 (500 V)

RE-2X(St)Y Multi-Core
RE-2X(St)Y Multi-Pair
RE-2X(St)Y Multi-Triple
RE-2X(St)Y PiMF
RE-2X(St)Y TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H

Fire Resistant

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-2X(St)Y
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)

Yellow or White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria
Conductor cross section

Mica-glass Tape + XLPE


Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5 x O.D

IEC 60331

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

130
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.3 mm)


2x0.5

0.6

0.9

7.2

48

1000

3x0.5

0.6

0.9

7.7

58

1000

4x0.5

0.6

0.9

8.3

70

1000

5x0.5

0.6

0.9

9.1

82

1000

6x0.5

0.6

0.9

9.8

94

1000

7x0.5

0.6

0.9

9.8

104

1000

8x0.5

0.6

1.0

11.6

123

1000

10x0.5

0.6

1.0

12.6

146

1000

12x0.5

0.6

1.0

13.0

166

1000

16x0.5

0.6

1.1

14.6

214

1000

20x0.5

0.6

1.1

16.2

259

1000

24x0.5

0.6

1.2

18.2

310

1000

30x0.5

0.6

1.2

19.2

371

1000

2x0.75

0.6

0.9

7.7

55

1000

3x0.75

0.6

0.9

8.1

69

1000

4x0.75

0.6

0.9

8.8

84

1000

5x0.75

0.6

0.9

9.6

99

1000

6x0.75

0.6

1.0

10.7

119

1000

7x0.75

0.6

1.0

10.7

131

1000

8x0.75

0.6

1.0

12.3

150

1000

10x0.75

0.6

1.1

13.6

184

1000

12x0.75

0.6

1.1

14.1

211

1000

16x0.75

0.6

1.1

15.6

267

1000

20x0.75

0.6

1.2

17.6

330

1000

24x0.75

0.6

1.2

19.4

388

1000

30x0.75

0.6

1.3

20.8

475

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

131

KCI

RE-2X(St)Y

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.9

8.0

62

1000

3x1

0.6

0.9

8.5

79

1000

4x1

0.6

0.9

9.3

97

1000

5x1

0.6

1.0

10.3

119

1000

6x1

0.6

1.0

11.2

138

1000

7x1

0.6

1.0

11.2

153

1000

8x1

0.6

1.0

13.0

175

1000

10x1

0.6

1.1

14.4

216

1000

12x1

0.6

1.1

14.8

248

1000

16x1

0.6

1.1

16.4

316

1000

20x1

0.6

1.2

18.5

392

1000

24x1

0.6

1.2

20.5

462

1000

30x1

0.6

1.3

21.9

567

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

132

2x1.5

0.6

0.9

8.6

76

1000

3x1.5

0.6

0.9

9.2

99

1000

4x1.5

0.6

1.0

10.2

127

1000

5x1.5

0.6

1.0

11.1

152

1000

6x1.5

0.6

1.0

12.1

176

1000

7x1.5

0.6

1.0

12.1

197

1000

8x1.5

0.6

1.1

14.3

231

1000

10x1.5

0.6

1.1

15.6

279

1000

12x1.5

0.6

1.1

16.1

323

1000

16x1.5

0.6

1.2

18.1

421

1000

20x1.5

0.6

1.2

20.1

514

1000

24x1.5

0.6

1.3

22.5

616

1000

30x1.5

0.6

1.4

24.0

757

1000

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

1.0

10.1

107

1000

3x2.5

0.7

1.0

10.7

141

1000

4x2.5

0.7

1.0

11.7

177

1000

5x2.5

0.7

1.1

13.0

218

1000

6x2.5

0.7

1.1

14.2

255

1000

7x2.5

0.7

1.1

14.2

287

1000

8x2.5

0.7

1.2

16.7

335

1000

10x2.5

0.7

1.2

18.2

406

1000

12x2.5

0.7

1.2

18.9

472

1000

16x2.5

0.7

1.3

21.2

617

1000

20x2.5

0.7

1.4

23.8

765

1000

24x2.5

0.7

1.5

26.6

916

500

30x2.5

0.7

1.5

28.2

1115

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

133

KCI

RE-2X(St)Y
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria
Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5 x O.D

IEC 60331

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

134
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.6

0.9

7.2

48

1000

2x2x0.5

0.6

1.0

10.8

83

1000

3x2x0.5

0.6

1.0

11.4

105

1000

4x2x0.5

0.6

1.0

12.5

128

1000

5x2x0.5

0.6

1.1

13.9

157

1000

6x2x0.5

0.6

1.1

15.2

181

1000

7x2x0.5

0.6

1.1

15.2

201

1000

10x2x0.5

0.6

1.2

19.6

283

1000

12x2x0.5

0.6

1.2

20.3

324

1000

16x2x0.5

0.6

1.3

22.8

419

1000

20x2x0.5

0.6

1.4

25.6

518

500

24x2x0.5

0.6

1.5

28.7

620

500

30x2x0.5

0.6

1.5

30.4

744

500

1x2x0.75

0.6

0.9

7.7

56

1000

2x2x0.75

0.6

1.0

11.4

98

1000

3x2x0.75

0.6

1.0

12.2

126

1000

4x2x0.75

0.6

1.1

13.6

161

1000

5x2x0.75

0.6

1.1

14.8

192

1000

6x2x0.75

0.6

1.1

16.2

223

1000

7x2x0.75

0.6

1.1

16.2

248

1000

10x2x0.75

0.6

1.3

21.2

358

1000

12x2x0.75

0.6

1.3

21.9

412

1000

16x2x0.75

0.6

1.4

24.6

534

500

20x2x0.75

0.6

1.4

27.5

650

500

24x2x0.75

0.6

1.5

30.7

778

500

30x2x0.75

0.6

1.6

32.8

952

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

135

KCI

RE-2X(St)Y

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

8.0

63

1000

2x2x1

0.6

1.0

12.0

112

1000

3x2x1

0.6

1.0

12.8

146

1000

4x2x1

0.6

1.1

14.3

187

1000

5x2x1

0.6

1.1

15.6

224

1000

6x2x1

0.6

1.1

17.1

261

1000

7x2x1

0.6

1.1

17.1

293

1000

10x2x1

0.6

1.3

22.4

422

1000

12x2x1

0.6

1.3

23.2

488

1000

16x2x1

0.6

1.4

26.0

635

500

20x2x1

0.6

1.5

29.2

786

500

24x2x1

0.6

1.6

32.7

940

500

30x2x1

0.6

1.6

34.7

1139

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

136

1x2x1.5

0.6

0.9

8.6

77

1000

2x2x1.5

0.6

1.0

13.0

140

1000

3x2x1.5

0.6

1.1

14.1

191

1000

4x2x1.5

0.6

1.1

15.5

240

1000

5x2x1.5

0.6

1.2

17.2

296

1000

6x2x1.5

0.6

1.2

18.8

346

1000

7x2x1.5

0.6

1.2

18.8

388

1000

10x2x1.5

0.6

1.4

24.5

559

500

12x2x1.5

0.6

1.4

25.4

649

500

16x2x1.5

0.6

1.5

28.5

846

500

20x2x1.5

0.6

1.6

32.1

1048

500

24x2x1.5

0.6

1.7

35.9

1253

500

30x2x1.5

0.6

1.8

38.3

1537

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.0

10.1

108

1000

2x2x2.5

0.7

1.1

15.2

199

1000

3x2x2.5

0.7

1.2

16.5

275

1000

4x2x2.5

0.7

1.2

18.1

347

1000

5x2x2.5

0.7

1.3

20.1

428

1000

6x2x2.5

0.7

1.3

22.0

503

1000

7x2x2.5

0.7

1.3

22.0

567

1000

10x2x2.5

0.7

1.5

28.8

815

500

12x2x2.5

0.7

1.6

30.0

962

500

16x2x2.5

0.7

1.7

33.7

1254

500

20x2x2.5

0.7

1.8

37.9

1553

500

24x2x2.5

0.7

1.9

42.4

1857

500

30x2x2.5

0.7

2.0

45.2

2280

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

137

KCI

RE-2X(St)Y
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

Instrument Cables

Criteria
Conductor cross section

7.5 x O.D

IEC 60331

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

138
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.6

0.9

7.7

59

1000

2x3x0.5

0.6

1.0

11.9

107

1000

3x3x0.5

0.6

1.0

12.7

138

1000

4x3x0.5

0.6

1.1

14.2

177

1000

5x3x0.5

0.6

1.1

15.5

211

1000

6x3x0.5

0.6

1.1

16.9

246

1000

7x3x0.5

0.6

1.1

16.9

275

1000

10x3x0.5

0.6

1.3

22.2

397

1000

12x3x0.5

0.6

1.3

22.9

459

1000

16x3x0.5

0.6

1.4

25.7

595

500

20x3x0.5

0.6

1.5

29.0

737

500

24x3x0.5

0.6

1.6

32.4

881

500

30x3x0.5

0.6

1.6

34.4

1065

500

1x3x0.75

0.6

0.9

8.1

70

1000

2x3x0.75

0.6

1.0

12.7

128

1000

3x3x0.75

0.6

1.1

13.7

174

1000

4x3x0.75

0.6

1.1

15.1

218

1000

5x3x0.75

0.6

1.1

16.6

262

1000

6x3x0.75

0.6

1.2

18.3

313

1000

7x3x0.75

0.6

1.2

18.3

351

1000

10x3x0.75

0.6

1.3

23.7

497

1000

12x3x0.75

0.6

1.4

24.8

586

500

16x3x0.75

0.6

1.5

27.8

762

500

20x3x0.75

0.6

1.5

31.1

931

500

24x3x0.75

0.6

1.7

35.0

1127

500

30x3x0.75

0.6

1.7

37.1

1367

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

139

KCI

RE-2X(St)Y

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

8.5

80

1000

2x3x1

0.6

1.0

13.4

148

1000

3x3x1

0.6

1.1

14.5

204

1000

4x3x1

0.6

1.1

15.9

256

1000

5x3x1

0.6

1.2

17.7

316

1000

6x3x1

0.6

1.2

19.3

370

1000

7x3x1

0.6

1.2

19.3

417

1000

10x3x1

0.6

1.4

25.3

600

500

12x3x1

0.6

1.4

26.2

698

500

16x3x1

0.6

1.5

29.4

911

500

20x3x1

0.6

1.6

33.1

1129

500

24x3x1

0.6

1.7

37.0

1351

500

30x3x1

0.6

1.8

39.5

1659

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

140

1x3x1.5

0.6

0.9

9.2

100

1000

2x3x1.5

0.6

1.1

14.7

194

1000

3x3x1.5

0.6

1.1

15.7

262

1000

4x3x1.5

0.6

1.2

17.5

340

1000

5x3x1.5

0.6

1.2

19.2

412

1000

6x3x1.5

0.6

1.3

21.2

492

1000

7x3x1.5

0.6

1.3

21.2

556

1000

10x3x1.5

0.6

1.5

27.7

799

500

12x3x1.5

0.6

1.5

28.7

932

500

16x3x1.5

0.6

1.6

32.2

1219

500

20x3x1.5

0.6

1.7

36.3

1511

500

24x3x1.5

0.6

1.8

40.5

1808

500

30x3x1.5

0.6

1.9

43.3

2225

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

10.7

143

1000

2x3x2.5

0.7

1.2

17.2

278

1000

3x3x2.5

0.7

1.2

18.4

381

1000

4x3x2.5

0.7

1.3

20.5

494

1000

5x3x2.5

0.7

1.3

22.5

602

1000

6x3x2.5

0.7

1.4

24.9

719

500

7x3x2.5

0.7

1.4

24.9

816

500

10x3x2.5

0.7

1.6

32.6

1171

500

12x3x2.5

0.7

1.7

33.9

1385

500

16x3x2.5

0.7

1.8

38.0

1812

500

20x3x2.5

0.7

1.9

42.8

2247

500

24x3x2.5

0.7

2.1

48.1

2706

500

30x3x2.5

0.7

2.2

51.3

3330

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

141

KCI

RE-2X(St)Y , PiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria
Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

7.5 x O.D

IEC 60331

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

142
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.3 mm)


1x2x0.5

0.6

0.9

7.6

58

1000

2x2x0.5

0.6

1.0

12.1

106

1000

3x2x0.5

0.6

1.0

12.9

137

1000

4x2x0.5

0.6

1.1

14.4

175

1000

5x2x0.5

0.6

1.1

15.7

209

1000

6x2x0.5

0.6

1.2

17.4

250

1000

7x2x0.5

0.6

1.2

17.4

278

1000

10x2x0.5

0.6

1.3

22.5

392

1000

12x2x0.5

0.6

1.3

23.3

452

1000

16x2x0.5

0.6

1.4

26.2

587

500

20x2x0.5

0.6

1.5

29.4

725

500

24x2x0.5

0.6

1.6

32.9

867

500

30x2x0.5

0.6

1.6

34.9

1048

500

1x2x0.75

0.6

0.9

8.0

66

1000

2x2x0.75

0.6

1.0

12.8

122

1000

3x2x0.75

0.6

1.1

13.9

165

1000

4x2x0.75

0.6

1.1

15.3

205

1000

5x2x0.75

0.6

1.1

16.7

246

1000

6x2x0.75

0.6

1.2

18.5

294

1000

7x2x0.75

0.6

1.2

18.5

329

1000

10x2x0.75

0.6

1.4

24.2

474

1000

12x2x0.75

0.6

1.4

25.1

547

500

16x2x0.75

0.6

1.5

28.1

710

500

20x2x0.75

0.6

1.6

31.6

878

500

24x2x0.75

0.6

1.7

35.4

1049

500

30x2x0.75

0.6

1.7

37.5

1269

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

143

KCI

RE-2X(St)Y , PiMF

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

8.4

74

1000

2x2x1

0.6

1.1

13.7

142

1000

3x2x1

0.6

1.1

14.6

186

1000

4x2x1

0.6

1.1

16.0

233

1000

5x2x1

0.6

1.2

17.8

287

1000

6x2x1

0.6

1.2

19.5

335

1000

7x2x1

0.6

1.2

19.5

376

1000

10x2x1

0.6

1.4

25.5

541

500

12x2x1

0.6

1.4

26.4

627

500

16x2x1

0.6

1.5

29.6

816

500

20x2x1

0.6

1.6

33.3

1010

500

24x2x1

0.6

1.7

37.3

1208

500

30x2x1

0.6

1.8

39.8

1480

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

144

1x2x1.5

0.6

0.9

9.0

88

1000

2x2x1.5

0.6

1.1

14.8

172

1000

3x2x1.5

0.6

1.1

15.7

229

1000

4x2x1.5

0.6

1.2

17.5

295

1000

5x2x1.5

0.6

1.2

19.3

355

1000

6x2x1.5

0.6

1.3

21.3

425

1000

7x2x1.5

0.6

1.3

21.3

477

1000

10x2x1.5

0.6

1.5

27.8

686

500

12x2x1.5

0.6

1.5

28.8

797

500

16x2x1.5

0.6

1.6

32.3

1038

500

20x2x1.5

0.6

1.7

36.4

1286

500

24x2x1.5

0.6

1.8

40.7

1537

500

30x2x1.5

0.6

1.9

43.4

1886

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , PiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.0

10.4

121

1000

2x2x2.5

0.7

1.2

17.2

236

1000

3x2x2.5

0.7

1.2

18.3

317

1000

4x2x2.5

0.7

1.3

20.4

409

1000

5x2x2.5

0.7

1.3

22.4

495

1000

6x2x2.5

0.7

1.4

24.8

591

500

7x2x2.5

0.7

1.4

24.8

667

500

10x2x2.5

0.7

1.6

32.4

958

500

12x2x2.5

0.7

1.7

33.8

1128

500

16x2x2.5

0.7

1.8

37.9

1470

500

20x2x2.5

0.7

1.9

42.7

1820

500

24x2x2.5

0.7

2.1

47.9

2194

500

30x2x2.5

0.7

2.2

51.1

2689

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

145

KCI

RE-2X(St)Y , TiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath

+90 oC

Instrument Cables

Conductor cross section

Mica-glass Tape + XLPE


Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

7.5 x O.D

IEC 60331

Screened

Standard Values

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

146
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.3 mm)


1x3x0.5

0.6

0.9

8.0

70

1000

2x3x0.5

0.6

1.0

13.4

131

1000

3x3x0.5

0.6

1.1

14.5

178

1000

4x3x0.5

0.6

1.1

16.0

222

1000

5x3x0.5

0.6

1.2

17.7

273

1000

6x3x0.5

0.6

1.2

19.4

318

1000

7x3x0.5

0.6

1.2

19.4

356

1000

10x3x0.5

0.6

1.4

25.4

513

500

12x3x0.5

0.6

1.4

26.3

594

500

16x3x0.5

0.6

1.5

29.5

772

500

20x3x0.5

0.6

1.6

33.2

955

500

24x3x0.5

0.6

1.7

37.1

1142

500

30x3x0.5

0.6

1.8

39.6

1398

500

1x3x0.75

0.6

0.9

8.5

81

1000

2x3x0.75

0.6

1.1

14.5

159

1000

3x3x0.75

0.6

1.1

15.4

211

1000

4x3x0.75

0.6

1.2

17.2

271

1000

5x3x0.75

0.6

1.2

18.9

326

1000

6x3x0.75

0.6

1.3

20.9

389

1000

7x3x0.75

0.6

1.3

20.9

437

1000

10x3x0.75

0.6

1.4

27.1

618

500

12x3x0.75

0.6

1.5

28.2

728

500

16x3x0.75

0.6

1.6

31.7

947

500

20x3x0.75

0.6

1.7

35.7

1172

500

24x3x0.75

0.6

1.8

39.9

1401

500

30x3x0.75

0.6

1.9

42.5

1717

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

147

KCI

RE-2X(St)Y , TiMF

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

8.9

91

1000

2x3x1

0.6

1.1

15.2

180

1000

3x3x1

0.6

1.1

16.2

241

1000

4x3x1

0.6

1.2

18.1

311

1000

5x3x1

0.6

1.2

19.9

376

1000

6x3x1

0.6

1.3

22.0

449

1000

7x3x1

0.6

1.3

22.0

506

1000

10x3x1

0.6

1.5

28.7

727

500

12x3x1

0.6

1.5

29.8

846

500

16x3x1

0.6

1.6

33.4

1103

500

20x3x1

0.6

1.7

37.6

1366

500

24x3x1

0.6

1.8

42.1

1634

500

30x3x1

0.6

1.9

44.9

2006

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

148

1x3x1.5

0.6

0.9

9.5

112

1000

2x3x1.5

0.6

1.1

16.4

223

1000

3x3x1.5

0.6

1.2

17.7

308

1000

4x3x1.5

0.6

1.2

19.6

391

1000

5x3x1.5

0.6

1.3

21.7

483

1000

6x3x1.5

0.6

1.4

24.0

576

1000

7x3x1.5

0.6

1.4

24.0

651

1000

10x3x1.5

0.6

1.6

31.4

934

500

12x3x1.5

0.6

1.6

32.5

1090

500

16x3x1.5

0.6

1.7

36.4

1424

500

20x3x1.5

0.6

1.9

41.2

1779

500

24x3x1.5

0.6

2.0

46.1

2127

500

30x3x1.5

0.6

2.1

49.2

2612

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)Y , TiMF

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm2

Overall
Diameter

Nominal cross section area of


conductor

Sheath thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

11.1

156

1000

2x3x2.5

0.7

1.2

19.1

311

1000

3x3x2.5

0.7

1.3

20.7

433

1000

4x3x2.5

0.7

1.3

22.8

553

1000

5x3x2.5

0.7

1.4

25.3

682

500

6x3x2.5

0.7

1.5

28.0

815

500

7x3x2.5

0.7

1.5

28.0

923

500

10x3x2.5

0.7

1.8

36.8

1338

500

12x3x2.5

0.7

1.8

38.1

1563

500

16x3x2.5

0.7

1.9

42.8

2043

500

20x3x2.5

0.7

2.1

48.3

2550

500

24x3x2.5

0.7

2.3

54.3

3068

250

30x3x2.5

0.7

2.4

57.8

3769

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)H

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

149

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-Y(St)YRY

EN 50288-7 (500 V)

RE-Y(St)YRY Multi-Core
RE-Y(St)YRY Multi-Pair
RE-Y(St)YRY Multi-Triple
RE-Y(St)YRY PiMF
RE-Y(St)YRY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-Y(St)YRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

152

PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.6

0.9

6.5

1.3

10.9

229

1000

3x0.5

0.6

0.9

6.8

1.3

11.2

247

1000

4x0.5

0.6

0.9

7.4

1.3

11.8

271

1000

5x0.5

0.6

0.9

8.0

1.3

12.4

296

1000

6x0.5

0.6

0.9

8.6

1.4

13.2

327

1000

7x0.5

0.6

0.9

8.6

1.4

13.2

336

1000

8x0.5

0.6

0.9

9.8

1.4

14.4

379

1000

10x0.5

0.6

0.9

10.7

1.4

15.3

421

1000

12x0.5

0.6

0.9

11.0

1.4

15.6

447

1000

16x0.5

0.6

0.9

12.2

1.4

16.8

514

1000

20x0.5

0.6

0.9

13.5

1.5

18.3

591

1000

24x0.5

0.6

0.9

14.9

1.5

19.7

667

1000

30x0.5

0.6

1.25

15.7

1.5

21.2

866

1000

2x0.75

0.6

0.9

6.9

1.3

11.3

250

1000

3x0.75

0.6

0.9

7.3

1.3

11.7

271

1000

4x0.75

0.6

0.9

7.9

1.3

12.3

299

1000

5x0.75

0.6

0.9

8.5

1.4

13.1

333

1000

6x0.75

0.6

0.9

9.2

1.4

13.8

363

1000

7x0.75

0.6

0.9

9.2

1.4

13.8

375

1000

8x0.75

0.6

0.9

10.6

1.4

15.2

427

1000

10x0.75

0.6

0.9

11.5

1.4

16.1

476

1000

12x0.75

0.6

0.9

11.9

1.4

16.5

508

1000

16x0.75

0.6

0.9

13.1

1.5

17.9

597

1000

20x0.75

0.6

0.9

14.6

1.5

19.4

685

1000

24x0.75

0.6

1.25

16.1

1.6

21.8

910

1000

30x0.75

0.6

1.25

17.1

1.6

22.8

1012

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

153

KCI

RE-Y(St)YRY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.9

7.3

1.3

11.7

265

1000

3x1

0.6

0.9

7.7

1.3

12.1

288

1000

4x1

0.6

0.9

8.3

1.4

12.9

325

1000

5x1

0.6

0.9

9.0

1.4

13.6

358

1000

6x1

0.6

0.9

9.8

1.4

14.4

396

1000

7x1

0.6

0.9

9.8

1.4

14.4

411

1000

8x1

0.6

0.9

11.3

1.4

15.9

467

1000

10x1

0.6

0.9

12.2

1.4

16.8

522

1000

12x1

0.6

0.9

12.6

1.5

17.4

568

1000

16x1

0.6

0.9

14.0

1.5

18.8

668

1000

20x1

0.6

0.9

15.6

1.5

20.4

770

1000

24x1

0.6

1.25

17.2

1.6

22.9

1022

1000

30x1

0.6

1.25

18.2

1.6

23.9

1142

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

154

2x1.5

0.6

0.9

7.9

1.3

12.3

293

1000

3x1.5

0.6

0.9

8.3

1.4

12.9

329

1000

4x1.5

0.6

0.9

9.0

1.4

13.6

373

1000

5x1.5

0.6

0.9

9.8

1.4

14.4

412

1000

6x1.5

0.6

0.9

10.7

1.4

15.3

457

1000

7x1.5

0.6

0.9

10.7

1.4

15.3

478

1000

8x1.5

0.6

0.9

12.3

1.5

17.1

549

1000

10x1.5

0.6

0.9

13.4

1.5

18.2

623

1000

12x1.5

0.6

0.9

13.9

1.5

18.7

674

1000

16x1.5

0.6

0.9

15.4

1.5

20.2

799

1000

20x1.5

0.6

1.25

17.2

1.6

22.9

1071

1000

24x1.5

0.6

1.25

19.0

1.6

24.7

1225

500

30x1.5

0.6

1.25

20.2

1.6

25.9

1391

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

0.9

9.1

1.4

13.7

356

1000

3x2.5

0.7

0.9

9.7

1.4

14.3

404

1000

4x2.5

0.7

0.9

10.5

1.4

15.1

456

1000

5x2.5

0.7

0.9

11.5

1.4

16.1

519

1000

6x2.5

0.7

0.9

12.5

1.5

17.3

585

1000

7x2.5

0.7

0.9

12.5

1.5

17.3

617

1000

8x2.5

0.7

0.9

14.6

1.5

19.4

708

1000

10x2.5

0.7

1.25

15.9

1.6

21.6

948

1000

12x2.5

0.7

1.25

16.5

1.6

22.2

1028

1000

16x2.5

0.7

1.25

18.3

1.6

24.0

1217

1000

20x2.5

0.7

1.25

20.5

1.7

26.4

1430

500

24x2.5

0.7

1.6

22.7

1.7

29.3

1820

500

30x2.5

0.7

1.6

24.1

1.8

30.9

2074

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

155

KCI

RE-Y(St)YRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

156

IEC 60708 Full color

Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

6.5

1.3

10.9

230

1000

2x2x0.5

0.6

0.9

9.2

1.4

13.8

327

1000

3x2x0.5

0.6

0.9

9.7

1.4

14.3

361

1000

4x2x0.5

0.6

0.9

10.6

1.4

15.2

404

1000

5x2x0.5

0.6

0.9

11.6

1.4

16.2

447

1000

6x2x0.5

0.6

0.9

12.6

1.5

17.4

499

1000

7x2x0.5

0.6

0.9

12.6

1.5

17.4

516

1000

10x2x0.5

0.6

1.25

16.1

1.5

21.6

796

1000

12x2x0.5

0.6

1.25

16.6

1.6

22.3

856

1000

16x2x0.5

0.6

1.25

18.5

1.6

24.2

999

1000

20x2x0.5

0.6

1.25

20.6

1.7

26.5

1155

500

24x2x0.5

0.6

1.6

23.0

1.7

29.6

1478

500

30x2x0.5

0.6

1.6

24.4

1.8

31.2

1663

500

1x2x0.75

0.6

0.9

6.9

1.3

11.3

251

1000

2x2x0.75

0.6

0.9

9.9

1.4

14.5

358

1000

3x2x0.75

0.6

0.9

10.5

1.4

15.1

398

1000

4x2x0.75

0.6

0.9

11.5

1.4

16.1

448

1000

5x2x0.75

0.6

0.9

12.5

1.5

17.3

511

1000

6x2x0.75

0.6

0.9

13.7

1.5

18.5

568

1000

7x2x0.75

0.6

0.9

13.7

1.5

18.5

592

1000

10x2x0.75

0.6

1.25

17.4

1.6

23.1

913

1000

12x2x0.75

0.6

1.25

18.0

1.6

23.7

988

1000

16x2x0.75

0.6

1.25

20.1

1.6

25.8

1147

500

20x2x0.75

0.6

1.6

22.5

1.7

29.1

1510

500

24x2x0.75

0.6

1.6

25.0

1.8

31.8

1731

500

30x2x0.75

0.6

1.6

26.6

1.8

33.4

1943

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

157

KCI

RE-Y(St)YRY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

7.3

1.3

11.7

265

1000

2x2x1

0.6

0.9

10.5

1.4

15.1

385

1000

3x2x1

0.6

0.9

11.1

1.4

15.7

433

1000

4x2x1

0.6

0.9

12.2

1.4

16.8

495

1000

5x2x1

0.6

0.9

13.3

1.5

18.1

565

1000

6x2x1

0.6

0.9

14.5

1.5

19.3

629

1000

7x2x1

0.6

0.9

14.5

1.5

19.3

659

1000

10x2x1

0.6

1.25

18.6

1.6

24.3

1015

1000

12x2x1

0.6

1.25

19.3

1.6

25.0

1093

500

16x2x1

0.6

1.25

21.5

1.7

27.4

1309

500

20x2x1

0.6

1.6

24.1

1.7

30.7

1697

500

24x2x1

0.6

1.6

26.8

1.8

33.6

1944

500

30x2x1

0.6

28.5

1.9

36.3

2469

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

158

1x2x1.5

0.6

0.9

7.9

1.3

12.3

294

1000

2x2x1.5

0.6

0.9

11.4

1.4

16.0

436

1000

3x2x1.5

0.6

0.9

12.2

1.4

16.8

501

1000

4x2x1.5

0.6

0.9

13.4

1.5

18.2

584

1000

5x2x1.5

0.6

0.9

14.6

1.5

19.4

661

1000

6x2x1.5

0.6

1.25

16.0

1.6

21.7

879

1000

7x2x1.5

0.6

1.25

16.0

1.6

21.7

921

1000

10x2x1.5

0.6

1.25

20.6

1.7

26.5

1220

500

12x2x1.5

0.6

1.25

21.3

1.7

27.2

1322

500

16x2x1.5

0.6

1.6

23.8

1.8

30.6

1779

500

20x2x1.5

0.6

1.6

26.7

1.8

33.5

2064

500

24x2x1.5

0.6

29.7

1.9

37.5

2646

500

30x2x1.5

0.6

31.6

2.0

39.6

3014

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

9.1

1.4

13.7

357

1000

2x2x2.5

0.7

0.9

13.5

1.5

18.3

550

1000

3x2x2.5

0.7

0.9

14.4

1.5

19.2

640

1000

4x2x2.5

0.7

1.25

15.8

1.6

21.5

878

1000

5x2x2.5

0.7

1.25

17.4

1.6

23.1

1001

1000

6x2x2.5

0.7

1.25

19.1

1.6

24.8

1126

500

7x2x2.5

0.7

1.25

19.1

1.6

24.8

1191

500

10x2x2.5

0.7

1.6

24.7

1.8

31.5

1791

500

12x2x2.5

0.7

1.6

25.6

1.8

32.4

1965

500

16x2x2.5

0.7

28.6

1.9

36.4

2620

500

20x2x2.5

0.7

32.5

2.0

40.5

3130

500

24x2x2.5

0.7

2.5

36.2

2.1

45.4

4011

500

30x2x2.5

0.7

2.5

38.5

2.2

47.9

4535

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

159

KCI

RE-Y(St)YRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC

+70 oC

IEC 60332-1

Instrument Cables

Criteria

160

Conductor cross section

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

6.8

1.3

11.2

247

1000

2x3x0.5

0.6

0.9

10.1

1.4

14.7

370

1000

3x3x0.5

0.6

0.9

10.8

1.4

15.4

414

1000

4x3x0.5

0.6

0.9

11.8

1.4

16.4

472

1000

5x3x0.5

0.6

0.9

12.9

1.5

17.7

533

1000

6x3x0.5

0.6

0.9

14.1

1.5

18.9

594

1000

7x3x0.5

0.6

0.9

14.1

1.5

18.9

620

1000

10x3x0.5

0.6

1.25

18.0

1.6

23.7

955

1000

12x3x0.5

0.6

1.25

18.6

1.6

24.3

1036

1000

16x3x0.5

0.6

1.25

20.7

1.7

26.6

1227

500

20x3x0.5

0.6

1.6

23.2

1.7

29.8

1605

500

24x3x0.5

0.6

1.6

25.8

1.8

32.6

1837

500

30x3x0.5

0.6

1.6

27.4

1.8

34.2

2066

500

1x3x0.75

0.6

0.9

7.3

1.3

11.7

272

1000

2x3x0.75

0.6

0.9

10.9

1.4

15.5

413

1000

3x3x0.75

0.6

0.9

11.6

1.4

16.2

467

1000

4x3x0.75

0.6

0.9

12.7

1.5

17.5

543

1000

5x3x0.75

0.6

0.9

13.9

1.5

18.7

613

1000

6x3x0.75

0.6

0.9

15.2

1.5

20.0

684

1000

7x3x0.75

0.6

0.9

15.2

1.5

20.0

719

1000

10x3x0.75

0.6

1.25

19.6

1.6

25.3

1107

500

12x3x0.75

0.6

1.25

20.2

1.6

25.9

1207

500

16x3x0.75

0.6

1.6

22.6

1.7

29.2

1624

500

20x3x0.75

0.6

1.6

25.3

1.8

32.1

1894

500

24x3x0.75

0.6

28.2

1.9

36.0

2431

500

30x3x0.75

0.6

30.0

1.9

37.8

2720

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

161

KCI

RE-Y(St)YRY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

7.7

1.3

12.1

289

1000

2x3x1

0.6

0.9

11.6

1.4

16.2

448

1000

3x3x1

0.6

0.9

12.3

1.4

16.9

511

1000

4x3x1

0.6

0.9

13.5

1.5

18.3

597

1000

5x3x1

0.6

0.9

14.8

1.5

19.6

682

1000

6x3x1

0.6

1.25

16.2

1.6

21.9

898

1000

7x3x1

0.6

1.25

16.2

1.6

21.9

943

1000

10x3x1

0.6

1.25

20.9

1.7

26.8

1252

500

12x3x1

0.6

1.6

21.6

1.7

28.2

1543

500

16x3x1

0.6

1.6

24.2

1.7

30.8

1818

500

20x3x1

0.6

1.6

27.1

1.8

33.9

2144

500

24x3x1

0.6

30.2

1.9

38.0

2722

500

30x3x1

0.6

32.1

1.9

39.9

3093

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

162

1x3x1.5

0.6

0.9

8.3

1.4

12.9

330

1000

2x3x1.5

0.6

0.9

12.7

1.5

17.5

525

1000

3x3x1.5

0.6

0.9

13.5

1.5

18.3

607

1000

4x3x1.5

0.6

0.9

14.9

1.5

19.7

711

1000

5x3x1.5

0.6

1.25

16.4

1.6

22.1

956

1000

6x3x1.5

0.6

1.25

17.9

1.6

23.6

1066

1000

7x3x1.5

0.6

1.25

17.9

1.6

23.6

1129

1000

10x3x1.5

0.6

1.6

23.1

1.7

29.7

1701

500

12x3x1.5

0.6

1.6

24.0

1.8

30.8

1865

500

16x3x1.5

0.6

1.6

26.8

1.8

33.6

2233

500

20x3x1.5

0.6

30.1

1.9

37.9

2901

500

24x3x1.5

0.6

34.0

2.0

42.0

3402

500

30x3x1.5

0.6

2.5

36.1

2.1

45.3

4325

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

9.7

1.4

14.3

406

1000

2x3x2.5

0.7

0.9

15.0

1.5

19.8

658

1000

3x3x2.5

0.7

1.25

16.0

1.6

21.7

923

1000

4x3x2.5

0.7

1.25

17.7

1.6

23.4

1080

1000

5x3x2.5

0.7

1.25

19.5

1.6

25.2

1238

500

6x3x2.5

0.7

1.25

21.4

1.7

27.3

1409

500

7x3x2.5

0.7

1.25

21.4

1.7

27.3

1507

500

10x3x2.5

0.7

27.8

1.9

35.6

2520

500

12x3x2.5

0.7

28.8

1.9

36.6

2753

500

16x3x2.5

0.7

32.6

2.0

40.6

3392

500

20x3x2.5

0.7

2.5

36.6

2.1

45.8

4408

500

24x3x2.5

0.7

2.5

40.9

2.2

50.3

5081

250

30x3x2.5

0.7

3.15

43.5

2.3

54.4

6505

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

163

KCI

RE-Y(St)YRY , PiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

164

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

6.8

1.3

11.2

247

1000

2x2x0.5

0.6

0.9

10.4

1.4

15.0

377

1000

3x2x0.5

0.6

0.9

11.0

1.4

15.6

420

1000

4x2x0.5

0.6

0.9

12.1

1.4

16.7

478

1000

5x2x0.5

0.6

0.9

13.2

1.5

18.0

538

1000

6x2x0.5

0.6

0.9

14.4

1.5

19.2

598

1000

7x2x0.5

0.6

0.9

14.4

1.5

19.2

624

1000

10x2x0.5

0.6

1.25

18.5

1.6

24.2

973

1000

12x2x0.5

0.6

1.25

19.2

1.6

24.9

1042

500

16x2x0.5

0.6

1.25

21.3

1.7

27.2

1231

500

20x2x0.5

0.6

1.6

23.9

1.7

30.5

1613

500

24x2x0.5

0.6

1.6

26.6

1.8

33.4

1844

500

30x2x0.5

0.6

28.3

1.9

36.1

2344

500

1x2x0.75

0.6

0.9

7.3

1.3

11.7

268

1000

2x2x0.75

0.6

0.9

11.1

1.4

15.7

409

1000

3x2x0.75

0.6

0.9

11.9

1.4

16.5

464

1000

4x2x0.75

0.6

0.9

13.0

1.5

17.8

537

1000

5x2x0.75

0.6

0.9

14.2

1.5

19.0

604

1000

6x2x0.75

0.6

0.9

15.6

1.5

20.4

671

1000

7x2x0.75

0.6

0.9

15.6

1.5

20.4

704

1000

10x2x0.75

0.6

1.25

20.0

1.6

25.7

1087

500

12x2x0.75

0.6

1.25

20.7

1.7

26.6

1190

500

16x2x0.75

0.6

1.6

23.1

1.7

29.7

1589

500

20x2x0.75

0.6

1.6

25.9

1.8

32.7

1847

500

24x2x0.75

0.6

28.9

1.9

36.7

2380

500

30x2x0.75

0.6

30.7

1.9

38.5

2648

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

165

KCI

RE-Y(St)YRY , PiMF

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

7.6

1.3

12.0

283

1000

2x2x1

0.6

0.9

11.8

1.4

16.4

443

1000

3x2x1

0.6

0.9

12.5

1.4

17.1

500

1000

4x2x1

0.6

0.9

13.8

1.5

18.6

580

1000

5x2x1

0.6

0.9

15.1

1.5

19.9

654

1000

6x2x1

0.6

1.25

16.5

1.6

22.2

874

1000

7x2x1

0.6

1.25

16.5

1.6

22.2

913

1000

10x2x1

0.6

1.25

21.3

1.7

27.2

1203

500

12x2x1

0.6

1.6

22.0

1.7

28.6

1488

500

16x2x1

0.6

1.6

24.6

1.8

31.4

1751

500

20x2x1

0.6

1.6

27.6

1.8

34.4

2041

500

24x2x1

0.6

30.8

1.9

38.6

2604

500

30x2x1

0.6

32.7

2.0

40.7

2954

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

166

1x2x1.5

0.6

0.9

8.2

1.4

12.8

318

1000

2x2x1.5

0.6

0.9

12.8

1.5

17.6

503

1000

3x2x1.5

0.6

0.9

13.7

1.5

18.5

579

1000

4x2x1.5

0.6

0.9

15.1

1.5

19.9

666

1000

5x2x1.5

0.6

1.25

16.5

1.6

22.2

899

1000

6x2x1.5

0.6

1.25

18.1

1.6

23.8

1008

1000

7x2x1.5

0.6

1.25

18.1

1.6

23.8

1059

1000

10x2x1.5

0.6

1.6

23.4

1.7

30.0

1586

500

12x2x1.5

0.6

1.6

24.3

1.8

31.1

1744

500

16x2x1.5

0.6

1.6

27.1

1.8

33.9

2065

500

20x2x1.5

0.6

30.4

1.9

38.2

2697

500

24x2x1.5

0.6

34.4

2.0

42.4

3152

500

30x2x1.5

0.6

2.5

36.5

2.1

45.7

3979

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

9.5

1.4

14.1

377

1000

2x2x2.5

0.7

0.9

15.1

1.5

19.9

614

1000

3x2x2.5

0.7

1.25

16.1

1.6

21.8

856

1000

4x2x2.5

0.7

1.25

17.7

1.6

23.4

991

1000

5x2x2.5

0.7

1.25

19.5

1.6

25.2

1127

500

6x2x2.5

0.7

1.25

21.4

1.7

27.3

1285

500

7x2x2.5

0.7

1.25

21.4

1.7

27.3

1361

500

10x2x2.5

0.7

27.8

1.9

35.6

2296

500

12x2x2.5

0.7

28.8

1.9

36.6

2486

500

16x2x2.5

0.7

32.7

2.0

40.7

3035

500

20x2x2.5

0.7

2.5

36.7

2.1

45.9

3961

500

24x2x2.5

0.7

2.5

41.0

2.2

50.4

4546

250

30x2x2.5

0.7

3.15

43.6

2.3

54.5

5835

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

167

KCI

RE-Y(St)YRY , TiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

Instrument Cables

+70 oC

Conductor cross section

PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

168
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

7.2

1.3

11.6

264

1000

2x3x0.5

0.6

0.9

11.5

1.4

16.1

427

1000

3x3x0.5

0.6

0.9

12.2

1.4

16.8

481

1000

4x3x0.5

0.6

0.9

13.4

1.5

18.2

556

1000

5x3x0.5

0.6

0.9

14.7

1.5

19.5

626

1000

6x3x0.5

0.6

1.25

16.1

1.5

21.6

828

1000

7x3x0.5

0.6

1.25

16.1

1.5

21.6

863

1000

10x3x0.5

0.6

1.25

20.7

1.7

26.6

1150

500

12x3x0.5

0.6

1.25

21.4

1.7

27.3

1239

500

16x3x0.5

0.6

1.6

23.9

1.7

30.5

1656

500

20x3x0.5

0.6

1.6

26.8

1.8

33.6

1926

500

24x3x0.5

0.6

29.9

1.9

37.7

2480

500

30x3x0.5

0.6

31.8

1.9

39.6

2791

500

1x3x0.75

0.6

0.9

7.6

1.3

12.0

289

1000

2x3x0.75

0.6

0.9

12.3

1.4

16.9

467

1000

3x3x0.75

0.6

0.9

13.1

1.5

17.9

543

1000

4x3x0.75

0.6

0.9

14.4

1.5

19.2

622

1000

5x3x0.75

0.6

1.25

15.9

1.5

21.4

830

1000

6x3x0.75

0.6

1.25

17.4

1.6

23.1

940

1000

7x3x0.75

0.6

1.25

17.4

1.6

23.1

985

1000

10x3x0.75

0.6

1.6

22.4

1.7

29.0

1477

500

12x3x0.75

0.6

1.6

23.2

1.7

29.8

1608

500

16x3x0.75

0.6

1.6

25.9

1.8

32.7

1914

500

20x3x0.75

0.6

29.1

1.9

36.9

2498

500

24x3x0.75

0.6

32.8

2.0

40.8

2897

500

30x3x0.75

0.6

2.5

34.9

2.1

44.1

3681

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

169

KCI

RE-Y(St)YRY , TiMF

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

8.0

1.3

12.4

307

1000

2x3x1

0.6

0.9

13.1

1.5

17.9

515

1000

3x3x1

0.6

0.9

13.9

1.5

18.7

594

1000

4x3x1

0.6

0.9

15.3

1.5

20.1

684

1000

5x3x1

0.6

1.25

16.8

1.6

22.5

925

1000

6x3x1

0.6

1.25

18.5

1.6

24.2

1028

1000

7x3x1

0.6

1.25

18.5

1.6

24.2

1082

1000

10x3x1

0.6

1.6

23.8

1.7

30.4

1635

500

12x3x1

0.6

1.6

24.7

1.8

31.5

1782

500

16x3x1

0.6

1.6

27.6

1.8

34.4

2132

500

20x3x1

0.6

31.0

1.9

38.8

2784

500

24x3x1

0.6

2.5

35.0

2.0

44.0

3619

500

30x3x1

0.6

2.5

37.2

2.1

46.4

4112

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

170

1x3x1.5

0.6

0.9

8.7

1.4

13.3

349

1000

2x3x1.5

0.6

0.9

14.3

1.5

19.1

587

1000

3x3x1.5

0.6

0.9

15.2

1.5

20.0

686

1000

4x3x1.5

0.6

1.25

16.8

1.6

22.5

946

1000

5x3x1.5

0.6

1.25

18.5

1.6

24.2

1078

1000

6x3x1.5

0.6

1.25

20.3

1.7

26.2

1221

500

7x3x1.5

0.6

1.25

20.3

1.7

26.2

1294

500

10x3x1.5

0.6

1.6

26.3

1.8

33.1

1929

500

12x3x1.5

0.6

1.6

27.2

1.8

34.0

2118

500

16x3x1.5

0.6

30.5

1.9

38.3

2834

500

20x3x1.5

0.6

2.5

34.7

2.1

43.9

3787

500

24x3x1.5

0.6

2.5

38.7

2.1

47.9

4335

500

30x3x1.5

0.6

2.5

41.1

2.2

50.5

4905

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

10.0

1.4

14.6

426

1000

2x3x2.5

0.7

1.25

16.8

1.6

22.5

875

1000

3x3x2.5

0.7

1.25

18.0

1.6

23.7

1017

1000

4x3x2.5

0.7

1.25

19.8

1.7

25.7

1208

500

5x3x2.5

0.7

1.6

21.9

1.7

28.5

1553

500

6x3x2.5

0.7

1.6

24.1

1.8

30.9

1765

500

7x3x2.5

0.7

1.6

24.1

1.8

30.9

1873

500

10x3x2.5

0.7

31.3

2.0

39.3

2815

500

12x3x2.5

0.7

32.9

2.0

40.9

3132

500

16x3x2.5

0.7

2.5

36.8

2.1

46.0

4189

500

20x3x2.5

0.7

2.5

41.4

2.2

50.8

4950

250

24x3x2.5

0.7

3.15

46.6

2.4

57.7

6477

250

30x3x2.5

0.7

3.15

49.6

2.5

60.9

7328

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

171

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-Y(St)YRY , PiMFY

EN 50288-7 (500 V)

RE-Y(St)YRY TiMFY

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HRH , PiMFH
RE-2X(St)HRH TiMFH

KCI

RE-Y(St)YRY , PiMFY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Individual Element
Jacket
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

174

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Each Screened Pair has individual PVC Jacket
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , PiMFY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

7.8

1.4

12.4

288

1000

2x2x0.5

0.6

0.9

12.2

1.5

17.0

444

1000

3x2x0.5

0.6

0.9

13.0

1.5

17.8

492

1000

4x2x0.5

0.6

0.9

14.2

1.5

19.0

562

1000

5x2x0.5

0.6

1.25

15.6

1.6

21.3

764

1000

6x2x0.5

0.6

1.25

17.1

1.6

22.8

840

1000

7x2x0.5

0.6

1.25

17.1

1.6

22.8

870

1000

10x2x0.5

0.6

1.6

22.1

1.7

28.7

1327

500

12x2x0.5

0.6

1.6

22.9

1.7

29.5

1412

500

16x2x0.5

0.6

1.6

25.5

1.8

32.3

1658

500

20x2x0.5

0.6

28.6

1.9

36.4

2173

500

24x2x0.5

0.6

32.3

2.0

40.3

2538

500

30x2x0.5

0.6

34.4

2.0

42.4

2821

500

1x2x0.75

0.6

0.9

8.3

1.4

12.9

305

1000

2x2x0.75

0.6

0.9

12.9

1.5

17.7

476

1000

3x2x0.75

0.6

0.9

13.8

1.5

18.6

538

1000

4x2x0.75

0.6

0.9

15.2

1.5

20.0

616

1000

5x2x0.75

0.6

1.25

16.6

1.6

22.3

830

1000

6x2x0.75

0.6

1.25

18.2

1.6

23.9

925

1000

7x2x0.75

0.6

1.25

18.2

1.6

23.9

962

1000

10x2x0.75

0.6

1.6

23.6

1.8

30.4

1459

500

12x2x0.75

0.6

1.6

24.4

1.8

31.2

1575

500

16x2x0.75

0.6

1.6

27.3

1.9

34.3

1853

500

20x2x0.75

0.6

30.6

2.0

38.6

2429

500

24x2x0.75

0.6

34.6

2.0

42.6

2812

500

30x2x0.75

0.6

2.5

36.8

2.1

46.0

3553

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

175

KCI

RE-Y(St)YRY , PiMFY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

8.6

1.4

13.2

320

1000

2x2x1

0.6

0.9

13.6

1.5

18.4

506

1000

3x2x1

0.6

0.9

14.5

1.5

19.3

575

1000

4x2x1

0.6

1.25

15.9

1.6

21.6

800

1000

5x2x1

0.6

1.25

17.5

1.6

23.2

891

1000

6x2x1

0.6

1.25

19.2

1.6

24.9

994

500

7x2x1

0.6

1.25

19.2

1.6

24.9

1037

500

10x2x1

0.6

1.6

24.8

1.8

31.6

1588

500

12x2x1

0.6

1.6

25.7

1.8

32.5

1701

500

16x2x1

0.6

28.8

1.9

36.6

2269

500

20x2x1

0.6

32.7

2.0

40.7

2691

500

24x2x1

0.6

2.5

36.5

2.1

45.7

3484

500

30x2x1

0.6

2.5

38.8

2.2

48.2

3916

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

176

1x2x1.5

0.6

0.9

9.2

1.4

13.8

350

1000

2x2x1.5

0.6

0.9

14.6

1.5

19.4

565

1000

3x2x1.5

0.6

1.25

15.6

1.6

21.3

783

1000

4x2x1.5

0.6

1.25

17.2

1.6

22.9

898

1000

5x2x1.5

0.6

1.25

18.9

1.6

24.6

1014

500

6x2x1.5

0.6

1.25

20.8

1.7

26.7

1142

500

7x2x1.5

0.6

1.25

20.8

1.7

26.7

1198

500

10x2x1.5

0.6

1.6

27.0

1.8

33.8

1811

500

12x2x1.5

0.6

28.0

1.9

35.8

2217

500

16x2x1.5

0.6

31.3

2.0

39.3

2628

500

20x2x1.5

0.6

2.5

35.6

2.1

44.8

3519

500

24x2x1.5

0.6

2.5

39.7

2.2

49.1

4023

500

30x2x1.5

0.6

2.5

42.2

2.3

51.8

4538

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , PiMFY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

10.5

1.4

15.1

410

1000

2x2x2.5

0.7

1.25

16.8

1.6

22.5

823

1000

3x2x2.5

0.7

1.25

18.0

1.6

23.7

938

1000

4x2x2.5

0.7

1.25

19.9

1.7

25.8

1102

500

5x2x2.5

0.7

1.6

21.9

1.7

28.5

1420

500

6x2x2.5

0.7

1.6

24.1

1.8

30.9

1606

500

7x2x2.5

0.7

1.6

24.1

1.8

30.9

1687

500

10x2x2.5

0.7

31.8

2.0

39.8

2607

500

12x2x2.5

0.7

32.9

2.0

40.9

2838

500

16x2x2.5

0.7

2.5

36.9

2.1

46.1

3760

500

20x2x2.5

0.7

2.5

41.4

2.3

51.0

4435

250

24x2x2.5

0.7

3.15

46.7

2.4

57.8

5835

250

30x2x2.5

0.7

3.15

49.7

2.5

61.0

6523

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH , PiMFH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

177

KCI

RE-Y(St)YRY , TiMFY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Individual Element
Jacket
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

Instrument Cables

+70 oC

178

Conductor cross section

PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Each Screened Triple has individual PVC Jacket
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , TiMFY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

8.2

1.4

12.8

306

1000

2x3x0.5

0.6

0.9

13.4

1.5

18.2

496

1000

3x3x0.5

0.6

0.9

14.2

1.5

19.0

561

1000

4x3x0.5

0.6

1.25

15.7

1.6

21.4

772

1000

5x3x0.5

0.6

1.25

17.2

1.6

22.9

869

1000

6x3x0.5

0.6

1.25

18.9

1.6

24.6

967

500

7x3x0.5

0.6

1.25

18.9

1.6

24.6

1006

500

10x3x0.5

0.6

1.6

24.4

1.8

31.2

1527

500

12x3x0.5

0.6

1.6

25.3

1.8

32.1

1649

500

16x3x0.5

0.6

28.3

1.9

36.1

2201

500

20x3x0.5

0.6

32.2

2.0

40.2

2579

500

24x3x0.5

0.6

2.5

35.9

2.1

45.1

3341

500

30x3x0.5

0.6

2.5

38.2

2.2

47.6

3748

500

1x3x0.75

0.6

0.9

8.6

1.4

13.2

326

1000

2x3x0.75

0.6

0.9

14.2

1.5

19.0

542

1000

3x3x0.75

0.6

0.9

15.2

1.5

20.0

617

1000

4x3x0.75

0.6

1.25

16.7

1.6

22.4

844

1000

5x3x0.75

0.6

1.25

18.4

1.6

24.1

953

1000

6x3x0.75

0.6

1.25

20.2

1.7

26.1

1083

500

7x3x0.75

0.6

1.25

20.2

1.7

26.1

1132

500

10x3x0.75

0.6

1.6

26.1

1.8

32.9

1698

500

12x3x0.75

0.6

1.6

27.1

1.8

33.9

1841

500

16x3x0.75

0.6

30.3

1.9

38.1

2464

500

20x3x0.75

0.6

34.5

2.0

42.5

2915

500

24x3x0.75

0.6

2.5

38.5

2.2

47.9

3759

500

30x3x0.75

0.6

2.5

40.9

2.2

50.3

4210

250

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

179

KCI

RE-Y(St)YRY , TiMFY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

9.0

1.4

13.6

350

1000

2x3x1

0.6

0.9

14.9

1.5

19.7

578

1000

3x3x1

0.6

1.25

16.0

1.6

21.7

804

1000

4x3x1

0.6

1.25

17.6

1.6

23.3

912

1000

5x3x1

0.6

1.25

19.4

1.6

25.1

1041

500

6x3x1

0.6

1.25

21.3

1.7

27.2

1173

500

7x3x1

0.6

1.25

21.3

1.7

27.2

1231

500

10x3x1

0.6

1.6

27.6

1.8

34.4

1860

500

12x3x1

0.6

28.6

1.9

36.4

2282

500

16x3x1

0.6

32.4

2.0

40.4

2764

500

20x3x1

0.6

2.5

36.4

2.1

45.6

3623

500

24x3x1

0.6

2.5

40.7

2.2

50.1

4140

250

30x3x1

0.6

2.5

43.2

2.3

52.8

4672

250

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

180

1x3x1.5

0.6

0.9

9.7

1.4

14.3

387

1000

2x3x1.5

0.6

1.25

16.2

1.6

21.9

787

1000

3x3x1.5

0.6

1.25

17.3

1.6

23.0

907

1000

4x3x1.5

0.6

1.25

19.1

1.6

24.8

1046

500

5x3x1.5

0.6

1.25

21.0

1.7

26.9

1207

500

6x3x1.5

0.6

1.6

23.1

1.8

29.9

1553

500

7x3x1.5

0.6

1.6

23.1

1.8

29.9

1631

500

10x3x1.5

0.6

30.0

1.9

37.8

2425

500

12x3x1.5

0.6

31.1

2.0

39.1

2662

500

16x3x1.5

0.6

2.5

35.3

2.1

44.5

3637

500

20x3x1.5

0.6

2.5

39.7

2.2

49.1

4231

500

24x3x1.5

0.6

3.15

44.7

2.4

55.8

5582

250

30x3x1.5

0.6

3.15

47.5

2.4

58.6

6222

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YRY , TiMFY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

11.0

1.4

15.6

459

1000

2x3x2.5

0.7

1.25

18.7

1.6

24.4

952

1000

3x3x2.5

0.7

1.25

20.0

1.7

25.9

1122

500

4x3x2.5

0.7

1.6

22.1

1.7

28.7

1491

500

5x3x2.5

0.7

1.6

24.4

1.8

31.2

1712

500

6x3x2.5

0.7

1.6

26.9

1.8

33.7

1923

500

7x3x2.5

0.7

1.6

26.9

1.8

33.7

2037

500

10x3x2.5

0.7

2.5

35.5

2.1

44.7

3547

500

12x3x2.5

0.7

2.5

36.8

2.1

46.0

3835

500

16x3x2.5

0.7

2.5

41.2

2.2

50.6

4620

250

20x3x2.5

0.7

3.15

46.8

2.4

57.9

6178

250

24x3x2.5

0.7

3.15

52.2

2.5

63.5

7074

250

30x3x2.5

0.7

3.15

56.0

2.6

67.5

8093

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH , TiMFH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

181

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)YRY

Fire Resistant

EN 50288-7 (500 V)

RE-2X(St)YRY Multi-Core
RE-2X(St)YRY Multi-Pair
RE-2X(St)YRY Multi-Triple
RE-2X(St)YRY PiMF
RE-2X(St)YRY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH

Fire Resistant

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-2X(St)YRY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Mica-glass Tape + XLPE


Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Yellow or White (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

184
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.6

0.9

7.4

1.3

11.8

254

1000

3x0.5

0.6

0.9

7.9

1.3

12.3

277

1000

4x0.5

0.6

0.9

8.5

1.3

12.9

304

1000

5x0.5

0.6

0.9

9.3

1.4

13.9

336

1000

6x0.5

0.6

0.9

10.0

1.4

14.6

369

1000

7x0.5

0.6

0.9

10.0

1.4

14.6

378

1000

8x0.5

0.6

0.9

11.6

1.4

16.2

429

1000

10x0.5

0.6

0.9

12.6

1.4

17.2

474

1000

12x0.5

0.6

0.9

13.0

1.4

17.6

507

1000

16x0.5

0.6

0.9

14.4

1.5

19.2

587

1000

20x0.5

0.6

1.25

16.0

1.5

21.5

799

1000

24x0.5

0.6

1.25

17.8

1.6

23.5

903

1000

30x0.5

0.6

1.25

18.8

1.6

24.5

991

500

2x0.75

0.6

0.9

7.9

1.3

12.3

275

1000

3x0.75

0.6

0.9

8.3

1.3

12.7

296

1000

4x0.75

0.6

0.9

9.0

1.4

13.6

337

1000

5x0.75

0.6

0.9

9.8

1.4

14.4

368

1000

6x0.75

0.6

0.9

10.7

1.4

15.3

404

1000

7x0.75

0.6

0.9

10.7

1.4

15.3

416

1000

8x0.75

0.6

0.9

12.3

1.4

16.9

472

1000

10x0.75

0.6

0.9

13.4

1.5

18.2

536

1000

12x0.75

0.6

0.9

13.9

1.5

18.7

570

1000

16x0.75

0.6

0.9

15.4

1.5

20.2

661

1000

20x0.75

0.6

1.25

17.2

1.6

22.9

900

1000

24x0.75

0.6

1.25

19.0

1.6

24.7

1020

500

30x0.75

0.6

1.25

20.2

1.6

25.9

1136

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

185

KCI

RE-2X(St)YRY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.9

8.2

1.3

12.6

289

1000

3x1

0.6

0.9

8.7

1.4

13.3

319

1000

4x1

0.6

0.9

9.5

1.4

14.1

358

1000

5x1

0.6

0.9

10.3

1.4

14.9

397

1000

6x1

0.6

0.9

11.2

1.4

15.8

437

1000

7x1

0.6

0.9

11.2

1.4

15.8

452

1000

8x1

0.6

0.9

13.0

1.4

17.6

511

1000

10x1

0.6

0.9

14.2

1.5

19.0

582

1000

12x1

0.6

0.9

14.6

1.5

19.4

628

1000

16x1

0.6

1.25

16.2

1.5

21.7

857

1000

20x1

0.6

1.25

18.1

1.6

23.8

997

1000

24x1

0.6

1.25

20.1

1.6

25.8

1120

500

30x1

0.6

1.25

21.3

1.6

27.0

1255

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

186

2x1.5

0.6

0.9

8.8

1.4

13.4

323

1000

3x1.5

0.6

0.9

9.4

1.4

14.0

359

1000

4x1.5

0.6

0.9

10.2

1.4

14.8

399

1000

5x1.5

0.6

0.9

11.1

1.4

15.7

445

1000

6x1.5

0.6

0.9

12.1

1.4

16.7

497

1000

7x1.5

0.6

0.9

12.1

1.4

16.7

518

1000

8x1.5

0.6

0.9

14.1

1.5

18.9

597

1000

10x1.5

0.6

0.9

15.4

1.5

20.2

674

1000

12x1.5

0.6

1.25

15.9

1.5

21.4

853

1000

16x1.5

0.6

1.25

17.7

1.6

23.4

1014

1000

20x1.5

0.6

1.25

19.7

1.6

25.4

1161

500

24x1.5

0.6

1.6

21.9

1.7

28.5

1501

500

30x1.5

0.6

1.6

23.2

1.7

29.8

1692

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

0.9

10.1

1.4

14.7

379

1000

3x2.5

0.7

0.9

10.7

1.4

15.3

427

1000

4x2.5

0.7

0.9

11.7

1.4

16.3

485

1000

5x2.5

0.7

0.9

12.8

1.5

17.6

556

1000

6x2.5

0.7

0.9

14.0

1.5

18.8

621

1000

7x2.5

0.7

0.9

14.0

1.5

18.8

653

1000

8x2.5

0.7

1.25

16.3

1.5

21.8

872

1000

10x2.5

0.7

1.25

17.8

1.6

23.5

1001

1000

12x2.5

0.7

1.25

18.5

1.6

24.2

1092

1000

16x2.5

0.7

1.25

20.6

1.6

26.3

1282

500

20x2.5

0.7

1.6

23.0

1.7

29.6

1682

500

24x2.5

0.7

1.6

25.6

1.8

32.4

1934

500

30x2.5

0.7

1.6

27.2

1.8

34.0

2192

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

187

KCI

RE-2X(St)YRY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

IEC 60708 Full color

Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

188
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

7.4

1.3

11.8

254

1000

2x2x0.5

0.6

0.9

10.8

1.4

15.4

368

1000

3x2x0.5

0.6

0.9

11.4

1.4

16.0

405

1000

4x2x0.5

0.6

0.9

12.5

1.4

17.1

456

1000

5x2x0.5

0.6

0.9

13.7

1.5

18.5

515

1000

6x2x0.5

0.6

0.9

15.0

1.5

19.8

568

1000

7x2x0.5

0.6

0.9

15.0

1.5

19.8

587

1000

10x2x0.5

0.6

1.25

19.2

1.6

24.9

915

500

12x2x0.5

0.6

1.25

19.9

1.6

25.6

981

500

16x2x0.5

0.6

1.6

22.2

1.7

28.8

1322

500

20x2x0.5

0.6

1.6

24.8

1.7

31.4

1510

500

24x2x0.5

0.6

1.6

27.7

1.8

34.5

1713

500

30x2x0.5

0.6

29.4

1.8

37.0

2152

500

1x2x0.75

0.6

0.9

7.9

1.3

12.3

275

1000

2x2x0.75

0.6

0.9

11.4

1.4

16.0

399

1000

3x2x0.75

0.6

0.9

12.2

1.4

16.8

447

1000

4x2x0.75

0.6

0.9

13.4

1.5

18.2

512

1000

5x2x0.75

0.6

0.9

14.6

1.5

19.4

571

1000

6x2x0.75

0.6

1.25

16.0

1.5

21.5

763

1000

7x2x0.75

0.6

1.25

16.0

1.5

21.5

788

1000

10x2x0.75

0.6

1.25

20.6

1.6

26.3

1032

500

12x2x0.75

0.6

1.25

21.3

1.6

27.0

1101

500

16x2x0.75

0.6

1.6

23.8

1.7

30.4

1488

500

20x2x0.75

0.6

1.6

26.7

1.8

33.5

1716

500

24x2x0.75

0.6

29.7

1.9

37.5

2228

500

30x2x0.75

0.6

31.6

1.9

39.4

2479

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

189

KCI

RE-2X(St)YRY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

8.2

1.3

12.6

289

1000

2x2x1

0.6

0.9

12.0

1.4

16.6

426

1000

3x2x1

0.6

0.9

12.8

1.4

17.4

481

1000

4x2x1

0.6

0.9

14.1

1.5

18.9

553

1000

5x2x1

0.6

0.9

15.4

1.5

20.2

624

1000

6x2x1

0.6

1.25

16.9

1.5

22.4

827

1000

7x2x1

0.6

1.25

16.9

1.5

22.4

858

1000

10x2x1

0.6

1.6

21.8

1.7

28.4

1306

500

12x2x1

0.6

1.6

22.6

1.7

29.2

1410

500

16x2x1

0.6

1.6

25.2

1.7

31.8

1629

500

20x2x1

0.6

28.2

1.8

35.8

2161

500

24x2x1

0.6

31.5

1.9

39.3

2440

500

30x2x1

0.6

33.5

1.9

41.3

2728

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

190

1x2x1.5

0.6

0.9

8.8

1.4

13.4

324

1000

2x2x1.5

0.6

0.9

13.0

1.4

17.6

482

1000

3x2x1.5

0.6

0.9

13.9

1.5

18.7

551

1000

4x2x1.5

0.6

0.9

15.3

1.5

20.1

634

1000

5x2x1.5

0.6

1.25

16.8

1.5

22.3

855

1000

6x2x1.5

0.6

1.25

18.4

1.6

24.1

954

1000

7x2x1.5

0.6

1.25

18.4

1.6

24.1

996

1000

10x2x1.5

0.6

1.6

23.7

1.7

30.3

1513

500

12x2x1.5

0.6

1.6

24.6

1.7

31.2

1624

500

16x2x1.5

0.6

1.6

27.5

1.8

34.3

1940

500

20x2x1.5

0.6

30.9

1.9

38.7

2519

500

24x2x1.5

0.6

34.5

2.0

42.5

2904

500

30x2x1.5

0.6

2.5

37.1

2.1

46.3

3755

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

10.1

1.4

14.7

380

1000

2x2x2.5

0.7

0.9

15.0

1.5

19.8

587

1000

3x2x2.5

0.7

1.25

16.1

1.5

21.6

810

1000

4x2x2.5

0.7

1.25

17.7

1.6

23.4

942

1000

5x2x2.5

0.7

1.25

19.5

1.6

25.2

1066

500

6x2x2.5

0.7

1.25

21.4

1.7

27.3

1213

500

7x2x2.5

0.7

1.25

21.4

1.7

27.3

1278

500

10x2x2.5

0.7

27.8

1.8

35.4

2164

500

12x2x2.5

0.7

28.8

1.9

36.6

2345

500

16x2x2.5

0.7

32.3

1.9

40.1

2800

500

20x2x2.5

0.7

2.5

36.7

2.1

45.9

3729

500

24x2x2.5

0.7

2.5

41.0

2.2

50.4

4268

250

30x2x2.5

0.7

3.15

43.6

2.3

54.5

5491

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

191

KCI

RE-2X(St)YRY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

IEC 60331

Instrument Cables

Criteria

192

Conductor cross section

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

7.9

1.3

12.3

278

1000

2x3x0.5

0.6

0.9

11.9

1.4

16.5

420

1000

3x3x0.5

0.6

0.9

12.7

1.4

17.3

472

1000

4x3x0.5

0.6

0.9

14.0

1.5

18.8

542

1000

5x3x0.5

0.6

0.9

15.3

1.5

20.1

605

1000

6x3x0.5

0.6

1.25

16.7

1.5

22.2

801

1000

7x3x0.5

0.6

1.25

16.7

1.5

22.2

829

1000

10x3x0.5

0.6

1.25

21.6

1.6

27.3

1097

500

12x3x0.5

0.6

1.6

22.3

1.7

28.9

1362

500

16x3x0.5

0.6

1.6

24.9

1.7

31.5

1588

500

20x3x0.5

0.6

28.0

1.8

35.6

2084

500

24x3x0.5

0.6

31.2

1.9

39.0

2379

500

30x3x0.5

0.6

33.2

1.9

41.0

2652

500

1x3x0.75

0.6

0.9

8.3

1.3

12.7

297

1000

2x3x0.75

0.6

0.9

12.7

1.4

17.3

463

1000

3x3x0.75

0.6

0.9

13.5

1.5

18.3

526

1000

4x3x0.75

0.6

0.9

14.9

1.5

19.7

604

1000

5x3x0.75

0.6

1.25

16.4

1.5

21.9

815

1000

6x3x0.75

0.6

1.25

17.9

1.6

23.6

908

1000

7x3x0.75

0.6

1.25

17.9

1.6

23.6

946

1000

10x3x0.75

0.6

1.6

23.1

1.7

29.7

1439

500

12x3x0.75

0.6

1.6

24.0

1.7

30.6

1540

500

16x3x0.75

0.6

1.6

26.8

1.8

33.6

1818

500

20x3x0.75

0.6

30.1

1.9

37.9

2383

500

24x3x0.75

0.6

33.6

1.9

41.4

2705

500

30x3x0.75

0.6

2.5

36.1

2.0

45.1

3534

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

193

KCI

RE-2X(St)YRY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

8.7

1.4

13.3

320

1000

2x3x1

0.6

0.9

13.4

1.4

18.0

497

1000

3x3x1

0.6

0.9

14.3

1.5

19.1

575

1000

4x3x1

0.6

1.25

15.7

1.5

21.2

785

1000

5x3x1

0.6

1.25

17.3

1.5

22.8

888

1000

6x3x1

0.6

1.25

18.9

1.6

24.6

1001

500

7x3x1

0.6

1.25

18.9

1.6

24.6

1048

500

10x3x1

0.6

1.6

24.5

1.7

31.1

1574

500

12x3x1

0.6

1.6

25.4

1.7

32.0

1710

500

16x3x1

0.6

28.4

1.8

36.0

2287

500

20x3x1

0.6

31.9

1.9

39.7

2657

500

24x3x1

0.6

2.5

35.6

2.0

44.6

3439

500

30x3x1

0.6

2.5

38.3

2.1

47.5

3924

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

194

1x3x1.5

0.6

0.9

9.4

1.4

14.0

361

1000

2x3x1.5

0.6

0.9

14.5

1.5

19.3

573

1000

3x3x1.5

0.6

0.9

15.5

1.5

20.3

663

1000

4x3x1.5

0.6

1.25

17.1

1.6

22.8

909

1000

5x3x1.5

0.6

1.25

18.8

1.6

24.5

1032

1000

6x3x1.5

0.6

1.25

20.6

1.6

26.3

1166

500

7x3x1.5

0.6

1.25

20.6

1.6

26.3

1230

500

10x3x1.5

0.6

1.6

26.7

1.8

33.5

1855

500

12x3x1.5

0.6

27.7

1.8

35.3

2279

500

16x3x1.5

0.6

31.0

1.9

38.8

2717

500

20x3x1.5

0.6

2.5

35.3

2.0

44.3

3633

500

24x3x1.5

0.6

2.5

39.3

2.1

48.5

4123

500

30x3x1.5

0.6

2.5

41.9

2.2

51.3

4681

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

10.7

1.4

15.3

429

1000

2x3x2.5

0.7

1.25

16.8

1.6

22.5

847

1000

3x3x2.5

0.7

1.25

18.0

1.6

23.7

977

1000

4x3x2.5

0.7

1.25

19.9

1.6

25.6

1145

500

5x3x2.5

0.7

1.6

21.9

1.7

28.5

1488

500

6x3x2.5

0.7

1.6

24.1

1.7

30.7

1676

500

7x3x2.5

0.7

1.6

24.1

1.7

30.7

1772

500

10x3x2.5

0.7

31.4

1.9

39.2

2672

500

12x3x2.5

0.7

32.5

1.9

40.3

2932

500

16x3x2.5

0.7

2.5

36.8

2.1

46.0

3989

500

20x3x2.5

0.7

2.5

41.4

2.2

50.8

4702

250

24x3x2.5

0.7

3.15

46.3

2.3

57.2

6046

250

30x3x2.5

0.7

3.15

49.7

2.4

60.8

6935

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

195

KCI

RE-2X(St)YRY , PiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

IEC 60708 Full color

Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

196
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

7.8

1.3

12.2

277

1000

2x2x0.5

0.6

0.9

12.1

1.4

16.7

426

1000

3x2x0.5

0.6

0.9

12.9

1.4

17.5

472

1000

4x2x0.5

0.6

0.9

14.2

1.5

19.0

541

1000

5x2x0.5

0.6

0.9

15.5

1.5

20.3

610

1000

6x2x0.5

0.6

1.25

17.0

1.5

22.5

810

1000

7x2x0.5

0.6

1.25

17.0

1.5

22.5

838

1000

10x2x0.5

0.6

1.6

21.9

1.7

28.5

1276

500

12x2x0.5

0.6

1.6

22.7

1.7

29.3

1374

500

16x2x0.5

0.6

1.6

25.4

1.7

32.0

1598

500

20x2x0.5

0.6

28.4

1.8

36.0

2101

500

24x2x0.5

0.6

31.7

1.9

39.5

2395

500

30x2x0.5

0.6

33.7

1.9

41.5

2664

500

1x2x0.75

0.6

0.9

8.2

1.3

12.6

293

1000

2x2x0.75

0.6

0.9

12.8

1.4

17.4

458

1000

3x2x0.75

0.6

0.9

13.7

1.5

18.5

523

1000

4x2x0.75

0.6

0.9

15.1

1.5

19.9

593

1000

5x2x0.75

0.6

1.25

16.5

1.5

22.0

800

1000

6x2x0.75

0.6

1.25

18.1

1.6

23.8

900

1000

7x2x0.75

0.6

1.25

18.1

1.6

23.8

935

1000

10x2x0.75

0.6

1.6

23.4

1.7

30.0

1408

500

12x2x0.75

0.6

1.6

24.3

1.7

30.9

1520

500

16x2x0.75

0.6

1.6

27.1

1.8

33.9

1784

500

20x2x0.75

0.6

30.4

1.9

38.2

2346

500

24x2x0.75

0.6

34.0

1.9

41.8

2655

500

30x2x0.75

0.6

2.5

36.5

2.0

45.5

3439

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

197

KCI

RE-2X(St)YRY , PiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

8.6

1.4

13.2

313

1000

2x2x1

0.6

0.9

13.5

1.5

18.3

493

1000

3x2x1

0.6

0.9

14.4

1.5

19.2

559

1000

4x2x1

0.6

1.25

15.8

1.5

21.3

762

1000

5x2x1

0.6

1.25

17.4

1.6

23.1

868

1000

6x2x1

0.6

1.25

19.1

1.6

24.8

967

500

7x2x1

0.6

1.25

19.1

1.6

24.8

1007

500

10x2x1

0.6

1.6

24.7

1.7

31.3

1516

500

12x2x1

0.6

1.6

25.6

1.7

32.2

1640

500

16x2x1

0.6

28.6

1.8

36.2

2193

500

20x2x1

0.6

32.1

1.9

39.9

2540

500

24x2x1

0.6

2.5

36.3

2.0

45.3

3376

500

30x2x1

0.6

2.5

38.6

2.1

47.8

3748

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

198

1x2x1.5

0.6

0.9

9.2

1.4

13.8

342

1000

2x2x1.5

0.6

0.9

14.6

1.5

19.4

551

1000

3x2x1.5

0.6

0.9

15.5

1.5

20.3

630

1000

4x2x1.5

0.6

1.25

17.1

1.6

22.8

865

1000

5x2x1.5

0.6

1.25

18.9

1.6

24.6

976

500

6x2x1.5

0.6

1.25

20.7

1.6

26.4

1099

500

7x2x1.5

0.6

1.25

20.7

1.6

26.4

1152

500

10x2x1.5

0.6

1.6

26.8

1.8

33.6

1743

500

12x2x1.5

0.6

27.8

1.8

35.4

2144

500

16x2x1.5

0.6

31.1

1.9

38.9

2537

500

20x2x1.5

0.6

2.5

35.4

2.0

44.4

3408

500

24x2x1.5

0.6

2.5

39.5

2.1

48.7

3893

500

30x2x1.5

0.6

2.5

42.0

2.2

51.4

4384

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

10.4

1.4

15.0

400

1000

2x2x2.5

0.7

1.25

16.8

1.6

22.5

804

1000

3x2x2.5

0.7

1.25

17.9

1.6

23.6

912

1000

4x2x2.5

0.7

1.25

19.8

1.6

25.5

1059

500

5x2x2.5

0.7

1.6

21.8

1.7

28.4

1381

500

6x2x2.5

0.7

1.6

24.0

1.7

30.6

1547

500

7x2x2.5

0.7

1.6

24.0

1.7

30.6

1622

500

10x2x2.5

0.7

31.2

1.9

39.0

2458

500

12x2x2.5

0.7

32.4

1.9

40.2

2675

500

16x2x2.5

0.7

2.5

36.7

2.1

45.9

3647

500

20x2x2.5

0.7

2.5

41.3

2.2

50.7

4274

250

24x2x2.5

0.7

3.15

46.1

2.3

57.0

5532

250

30x2x2.5

0.7

3.15

49.5

2.4

60.6

6294

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

199

KCI

RE-2X(St)YRY , TiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Conductor cross section

Mica-glass Tape + XLPE


Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria

Blue,White,Red (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

200
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

8.2

1.3

12.6

296

1000

2x3x0.5

0.6

0.9

13.4

1.4

18.0

480

1000

3x3x0.5

0.6

0.9

14.3

1.5

19.1

550

1000

4x3x0.5

0.6

1.25

15.8

1.5

21.3

750

1000

5x3x0.5

0.6

1.25

17.3

1.5

22.8

845

1000

6x3x0.5

0.6

1.25

19.0

1.6

24.7

949

500

7x3x0.5

0.6

1.25

19.0

1.6

24.7

987

500

10x3x0.5

0.6

1.6

24.6

1.7

31.2

1488

500

12x3x0.5

0.6

1.6

25.5

1.7

32.1

1606

500

16x3x0.5

0.6

28.5

1.8

36.1

2148

500

20x3x0.5

0.6

32.0

1.9

39.8

2484

500

24x3x0.5

0.6

2.5

36.1

2.0

45.1

3309

500

30x3x0.5

0.6

2.5

38.4

2.1

47.6

3664

500

1x3x0.75

0.6

0.9

8.7

1.4

13.3

321

1000

2x3x0.75

0.6

0.9

14.3

1.5

19.1

531

1000

3x3x0.75

0.6

0.9

15.2

1.5

20.0

604

1000

4x3x0.75

0.6

1.25

16.8

1.5

22.3

830

1000

5x3x0.75

0.6

1.25

18.5

1.6

24.2

945

1000

6x3x0.75

0.6

1.25

20.3

1.6

26.0

1052

500

7x3x0.75

0.6

1.25

20.3

1.6

26.0

1099

500

10x3x0.75

0.6

1.6

26.3

1.8

33.1

1665

500

12x3x0.75

0.6

1.6

27.2

1.8

34.0

1804

500

16x3x0.75

0.6

30.5

1.9

38.3

2416

500

20x3x0.75

0.6

34.3

2.0

42.3

2795

500

24x3x0.75

0.6

2.5

38.7

2.1

47.9

3711

500

30x3x0.75

0.6

2.5

41.1

2.1

50.3

4108

250

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

201

KCI

RE-2X(St)YRY , TiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

9.1

1.4

13.7

344

1000

2x3x1

0.6

0.9

15.0

1.5

19.8

567

1000

3x3x1

0.6

1.25

16.0

1.5

21.5

781

1000

4x3x1

0.6

1.25

17.7

1.6

23.4

904

1000

5x3x1

0.6

1.25

19.5

1.6

25.2

1020

500

6x3x1

0.6

1.25

21.4

1.6

27.1

1137

500

7x3x1

0.6

1.25

21.4

1.6

27.1

1194

500

10x3x1

0.6

27.7

1.8

35.3

2073

500

12x3x1

0.6

28.8

1.8

36.4

2223

500

16x3x1

0.6

32.2

1.9

40.0

2633

500

20x3x1

0.6

2.5

36.6

2.0

45.6

3536

500

24x3x1

0.6

2.5

40.9

2.1

50.1

4038

250

30x3x1

0.6

2.5

43.5

2.2

52.9

4553

250

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

202

1x3x1.5

0.6

0.9

9.7

1.4

14.3

380

1000

2x3x1.5

0.6

1.25

16.2

1.5

21.7

764

1000

3x3x1.5

0.6

1.25

17.3

1.6

23.0

890

1000

4x3x1.5

0.6

1.25

19.2

1.6

24.9

1024

500

5x3x1.5

0.6

1.25

21.1

1.6

26.8

1170

500

6x3x1.5

0.6

1.6

23.2

1.7

29.8

1510

500

7x3x1.5

0.6

1.6

23.2

1.7

29.8

1585

500

10x3x1.5

0.6

30.2

1.9

38.0

2376

500

12x3x1.5

0.6

31.3

1.9

39.1

2590

500

16x3x1.5

0.6

2.5

35.4

2.0

44.4

3546

500

20x3x1.5

0.6

2.5

39.8

2.1

49.0

4122

500

24x3x1.5

0.6

2.5

44.5

2.2

53.9

4705

250

30x3x1.5

0.6

3.15

47.4

2.3

58.3

6022

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

11.1

1.4

15.7

450

1000

2x3x2.5

0.7

1.25

18.7

1.6

24.4

932

1000

3x3x2.5

0.7

1.25

20.1

1.6

25.8

1085

500

4x3x2.5

0.7

1.6

22.2

1.7

28.8

1457

500

5x3x2.5

0.7

1.6

24.5

1.8

31.3

1670

500

6x3x2.5

0.7

1.6

27.0

1.8

33.8

1890

500

7x3x2.5

0.7

1.6

27.0

1.8

33.8

1998

500

10x3x2.5

0.7

2.5

35.6

2.0

44.6

3449

500

12x3x2.5

0.7

2.5

36.9

2.1

46.1

3782

500

16x3x2.5

0.7

2.5

41.4

2.2

50.8

4498

250

20x3x2.5

0.7

3.15

46.9

2.3

57.8

6003

250

24x3x2.5

0.7

3.15

52.5

2.5

63.8

6891

250

30x3x2.5

0.7

3.15

55.8

2.5

67.1

7788

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

203

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-Y(St)YBY

EN 50288-7 (500 V)

RE-Y(St)YBY Multi-Core
RE-Y(St)YBY Multi-Pair
RE-Y(St)YBY Multi-Triple
RE-Y(St)YBY PiMF
RE-Y(St)YBY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-Y(St)YBY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

206

PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.6

0.2

6.5

1.3

9.9

149

1000

3x0.5

0.6

0.2

6.8

1.3

10.2

164

1000

4x0.5

0.6

0.2

7.4

1.3

10.8

182

1000

5x0.5

0.6

0.2

8.0

1.3

11.4

201

1000

6x0.5

0.6

0.2

8.6

1.3

12.0

220

1000

7x0.5

0.6

0.2

8.6

1.3

12.0

229

1000

8x0.5

0.6

0.2

9.8

1.4

13.4

265

1000

10x0.5

0.6

0.2

10.7

1.4

14.3

298

1000

12x0.5

0.6

0.2

11.0

1.4

14.6

321

1000

16x0.5

0.6

0.2

12.2

1.4

15.8

376

1000

20x0.5

0.6

0.2

13.5

1.4

17.1

435

1000

24x0.5

0.6

0.2

14.9

1.5

18.7

502

1000

30x0.5

0.6

0.2

15.7

1.5

19.5

570

1000

2x0.75

0.6

0.2

6.9

1.3

10.3

163

1000

3x0.75

0.6

0.2

7.3

1.3

10.7

181

1000

4x0.75

0.6

0.2

7.9

1.3

11.3

203

1000

5x0.75

0.6

0.2

8.5

1.3

11.9

226

1000

6x0.75

0.6

0.2

9.2

1.4

12.8

255

1000

7x0.75

0.6

0.2

9.2

1.4

12.8

267

1000

8x0.75

0.6

0.2

10.6

1.4

14.2

304

1000

10x0.75

0.6

0.2

11.5

1.4

15.1

344

1000

12x0.75

0.6

0.2

11.9

1.4

15.5

374

1000

16x0.75

0.6

0.2

13.1

1.4

16.7

443

1000

20x0.75

0.6

0.2

14.6

1.5

18.4

523

1000

24x0.75

0.6

0.2

16.1

1.5

19.9

599

1000

30x0.75

0.6

0.2

17.1

1.5

20.9

686

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

207

KCI

RE-Y(St)YBY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.2

7.3

1.3

10.7

174

1000

3x1

0.6

0.2

7.7

1.3

11.1

196

1000

4x1

0.6

0.2

8.3

1.3

11.7

222

1000

5x1

0.6

0.2

9.0

1.3

12.4

249

1000

6x1

0.6

0.2

9.8

1.4

13.4

282

1000

7x1

0.6

0.2

9.8

1.4

13.4

297

1000

8x1

0.6

0.2

11.3

1.4

14.9

338

1000

10x1

0.6

0.2

12.2

1.4

15.8

385

1000

12x1

0.6

0.2

12.6

1.4

16.2

422

1000

16x1

0.6

0.2

14.0

1.5

17.8

512

1000

20x1

0.6

0.2

15.6

1.5

19.4

599

1000

24x1

0.6

0.2

17.2

1.5

21.0

688

1000

30x1

0.6

0.2

18.2

1.5

22.0

795

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

208

2x1.5

0.6

0.2

7.9

1.3

11.3

197

1000

3x1.5

0.6

0.2

8.3

1.3

11.7

226

1000

4x1.5

0.6

0.2

9.0

1.3

12.4

259

1000

5x1.5

0.6

0.2

9.8

1.4

13.4

299

1000

6x1.5

0.6

0.2

10.7

1.4

14.3

334

1000

7x1.5

0.6

0.2

10.7

1.4

14.3

355

1000

8x1.5

0.6

0.2

12.3

1.4

15.9

405

1000

10x1.5

0.6

0.2

13.4

1.4

17.0

466

1000

12x1.5

0.6

0.2

13.9

1.5

17.7

522

1000

16x1.5

0.6

0.2

15.4

1.5

19.2

632

1000

20x1.5

0.6

0.2

17.2

1.5

21.0

746

1000

24x1.5

0.6

0.2

19.0

1.6

23.0

872

1000

30x1.5

0.6

0.2

20.2

1.6

24.2

1016

1000

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

0.2

9.1

1.4

12.7

248

1000

3x2.5

0.7

0.2

9.7

1.4

13.3

290

1000

4x2.5

0.7

0.2

10.5

1.4

14.1

338

1000

5x2.5

0.7

0.2

11.5

1.4

15.1

387

1000

6x2.5

0.7

0.2

12.5

1.4

16.1

437

1000

7x2.5

0.7

0.2

12.5

1.4

16.1

469

1000

8x2.5

0.7

0.2

14.6

1.5

18.4

545

1000

10x2.5

0.7

0.2

15.9

1.5

19.7

634

1000

12x2.5

0.7

0.2

16.5

1.5

20.3

708

1000

16x2.5

0.7

0.2

18.3

1.6

22.3

879

1000

20x2.5

0.7

0.2

20.5

1.6

24.5

1047

1000

24x2.5

0.7

0.2

22.7

1.7

26.9

1228

500

30x2.5

0.7

0.2

24.1

1.7

28.3

1446

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

209

KCI

RE-Y(St)YBY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

210

IEC 60708 Full color

Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.2

6.5

1.3

9.9

149

1000

2x2x0.5

0.6

0.2

9.2

1.3

12.6

214

1000

3x2x0.5

0.6

0.2

9.7

1.4

13.3

247

1000

4x2x0.5

0.6

0.2

10.6

1.4

14.2

281

1000

5x2x0.5

0.6

0.2

11.6

1.4

15.2

316

1000

6x2x0.5

0.6

0.2

12.6

1.4

16.2

352

1000

7x2x0.5

0.6

0.2

12.6

1.4

16.2

370

1000

10x2x0.5

0.6

0.2

16.1

1.5

19.9

492

1000

12x2x0.5

0.6

0.2

16.6

1.5

20.4

538

1000

16x2x0.5

0.6

0.2

18.5

1.6

22.5

652

1000

20x2x0.5

0.6

0.2

20.6

1.6

24.6

763

500

24x2x0.5

0.6

0.2

23.0

1.7

27.2

888

500

30x2x0.5

0.6

0.2

24.4

1.7

28.6

1021

500

1x2x0.75

0.6

0.2

6.9

1.3

10.3

163

1000

2x2x0.75

0.6

0.2

9.9

1.4

13.5

244

1000

3x2x0.75

0.6

0.2

10.5

1.4

14.1

279

1000

4x2x0.75

0.6

0.2

11.5

1.4

15.1

321

1000

5x2x0.75

0.6

0.2

12.5

1.4

16.1

364

1000

6x2x0.75

0.6

0.2

13.7

1.5

17.5

415

1000

7x2x0.75

0.6

0.2

13.7

1.5

17.5

439

1000

10x2x0.75

0.6

0.2

17.4

1.5

21.2

580

1000

12x2x0.75

0.6

0.2

18.0

1.6

22.0

648

1000

16x2x0.75

0.6

0.2

20.1

1.6

24.1

782

1000

20x2x0.75

0.6

0.2

22.5

1.7

26.7

932

500

24x2x0.75

0.6

0.2

25.0

1.7

29.2

1076

500

30x2x0.75

0.6

0.2

26.6

1.7

30.8

1250

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

211

KCI

RE-Y(St)YBY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.2

7.3

1.3

10.7

175

1000

2x2x1

0.6

0.2

10.5

1.4

14.1

266

1000

3x2x1

0.6

0.2

11.1

1.4

14.7

308

1000

4x2x1

0.6

0.2

12.2

1.4

15.8

357

1000

5x2x1

0.6

0.2

13.3

1.4

16.9

407

1000

6x2x1

0.6

0.2

14.5

1.5

18.3

466

1000

7x2x1

0.6

0.2

14.5

1.5

18.3

496

1000

10x2x1

0.6

0.2

18.6

1.6

22.6

669

1000

12x2x1

0.6

0.2

19.3

1.6

23.3

741

1000

16x2x1

0.6

0.2

21.5

1.6

25.5

902

500

20x2x1

0.6

0.2

24.1

1.7

28.3

1081

500

24x2x1

0.6

0.2

26.8

1.7

31.0

1253

500

30x2x1

0.6

0.2

28.5

1.8

32.9

1477

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

212

1x2x1.5

0.6

0.2

7.9

1.3

11.3

198

1000

2x2x1.5

0.6

0.2

11.4

1.4

15.0

309

1000

3x2x1.5

0.6

0.2

12.2

1.4

15.8

364

1000

4x2x1.5

0.6

0.2

13.4

1.4

17.0

427

1000

5x2x1.5

0.6

0.2

14.6

1.5

18.4

499

1000

6x2x1.5

0.6

0.2

16.0

1.5

19.8

566

1000

7x2x1.5

0.6

0.2

16.0

1.5

19.8

608

1000

10x2x1.5

0.6

0.2

20.6

1.6

24.6

827

500

12x2x1.5

0.6

0.2

21.3

1.6

25.3

925

500

16x2x1.5

0.6

0.2

23.8

1.7

28.0

1149

500

20x2x1.5

0.6

0.2

26.7

1.8

31.1

1384

500

24x2x1.5

0.6

0.2

29.7

1.8

34.1

1611

500

30x2x1.5

0.6

0.2

31.6

1.9

36.2

1913

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.2

9.1

1.4

12.7

249

1000

2x2x2.5

0.7

0.2

13.5

1.5

17.3

400

1000

3x2x2.5

0.7

0.2

14.4

1.5

18.2

482

1000

4x2x2.5

0.7

0.2

15.8

1.5

19.6

574

1000

5x2x2.5

0.7

0.2

17.4

1.5

21.2

668

1000

6x2x2.5

0.7

0.2

19.1

1.6

23.1

773

1000

7x2x2.5

0.7

0.2

19.1

1.6

23.1

838

1000

10x2x2.5

0.7

0.2

24.7

1.7

28.9

1150

500

12x2x2.5

0.7

0.2

25.6

1.7

29.8

1297

500

16x2x2.5

0.7

0.2

28.6

1.8

33.0

1629

500

20x2x2.5

0.7

0.2

32.5

1.9

37.1

2009

500

24x2x2.5

0.7

0.5

36.2

2.0

42.2

2801

500

30x2x2.5

0.7

0.5

38.5

2.1

44.7

3284

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

213

KCI

RE-Y(St)YBY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Tapes
Outer Sheath
Extruded PVC

+70 oC

IEC 60332-1

Instrument Cables

Criteria

214

Conductor cross section

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.2

6.8

1.3

10.2

164

1000

2x3x0.5

0.6

0.2

10.1

1.4

13.7

254

1000

3x3x0.5

0.6

0.2

10.8

1.4

14.4

292

1000

4x3x0.5

0.6

0.2

11.8

1.4

15.4

337

1000

5x3x0.5

0.6

0.2

12.9

1.4

16.5

383

1000

6x3x0.5

0.6

0.2

14.1

1.5

17.9

438

1000

7x3x0.5

0.6

0.2

14.1

1.5

17.9

465

1000

10x3x0.5

0.6

0.2

18.0

1.5

21.8

616

1000

12x3x0.5

0.6

0.2

18.6

1.6

22.6

690

1000

16x3x0.5

0.6

0.2

20.7

1.6

24.7

836

500

20x3x0.5

0.6

0.2

23.2

1.7

27.4

999

500

24x3x0.5

0.6

0.2

25.8

1.7

30.0

1156

500

30x3x0.5

0.6

0.2

27.4

1.8

31.8

1359

500

1x3x0.75

0.6

0.2

7.3

1.3

10.7

182

1000

2x3x0.75

0.6

0.2

10.9

1.4

14.5

287

1000

3x3x0.75

0.6

0.2

11.6

1.4

15.2

336

1000

4x3x0.75

0.6

0.2

12.7

1.4

16.3

392

1000

5x3x0.75

0.6

0.2

13.9

1.5

17.7

456

1000

6x3x0.75

0.6

0.2

15.2

1.5

19.0

516

1000

7x3x0.75

0.6

0.2

15.2

1.5

19.0

552

1000

10x3x0.75

0.6

0.2

19.6

1.6

23.6

748

1000

12x3x0.75

0.6

0.2

20.2

1.6

24.2

832

1000

16x3x0.75

0.6

0.2

22.6

1.7

26.8

1030

500

20x3x0.75

0.6

0.2

25.3

1.7

29.5

1225

500

24x3x0.75

0.6

0.2

28.2

1.8

32.6

1437

500

30x3x0.75

0.6

0.2

30.0

1.8

34.4

1686

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

215

KCI

RE-Y(St)YRY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.2

7.7

1.3

11.1

197

1000

2x3x1

0.6

0.2

11.6

1.4

15.2

316

1000

3x3x1

0.6

0.2

12.3

1.4

15.9

375

1000

4x3x1

0.6

0.2

13.5

1.4

17.1

441

1000

5x3x1

0.6

0.2

14.8

1.5

18.6

517

1000

6x3x1

0.6

0.2

16.2

1.5

20.0

587

1000

7x3x1

0.6

0.2

16.2

1.5

20.0

632

1000

10x3x1

0.6

0.2

20.9

1.6

24.9

861

500

12x3x1

0.6

0.2

21.6

1.6

25.6

965

500

16x3x1

0.6

0.2

24.2

1.7

28.4

1203

500

20x3x1

0.6

0.2

27.1

1.7

31.3

1438

500

24x3x1

0.6

0.2

30.2

1.8

34.6

1691

500

30x3x1

0.6

0.2

32.1

1.9

36.7

2012

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

216

1x3x1.5

0.6

0.2

8.3

1.3

11.7

227

1000

2x3x1.5

0.6

0.2

12.7

1.4

16.3

373

1000

3x3x1.5

0.6

0.2

13.5

1.5

17.3

458

1000

4x3x1.5

0.6

0.2

14.9

1.5

18.7

546

1000

5x3x1.5

0.6

0.2

16.4

1.5

20.2

635

1000

6x3x1.5

0.6

0.2

17.9

1.6

21.9

736

1000

7x3x1.5

0.6

0.2

17.9

1.6

21.9

798

1000

10x3x1.5

0.6

0.2

23.1

1.7

27.3

1095

500

12x3x1.5

0.6

0.2

24.0

1.7

28.2

1236

500

16x3x1.5

0.6

0.2

26.8

1.8

31.2

1554

500

20x3x1.5

0.6

0.2

30.1

1.8

34.5

1869

500

24x3x1.5

0.6

0.2

34.0

1.9

38.6

2240

500

30x3x1.5

0.6

0.5

36.1

2.0

42.1

3112

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.2

9.7

1.4

13.3

292

1000

2x3x2.5

0.7

0.2

15.0

1.5

18.8

494

1000

3x3x2.5

0.7

0.2

16.0

1.5

19.8

610

1000

4x3x2.5

0.7

0.2

17.7

1.6

21.7

747

1000

5x3x2.5

0.7

0.2

19.5

1.6

23.5

879

1000

6x3x2.5

0.7

0.2

21.4

1.6

25.4

1012

500

7x3x2.5

0.7

0.2

21.4

1.6

25.4

1110

500

10x3x2.5

0.7

0.2

27.8

1.8

32.2

1548

500

12x3x2.5

0.7

0.2

28.8

1.8

33.2

1763

500

16x3x2.5

0.7

0.2

32.6

1.9

37.2

2272

500

20x3x2.5

0.7

0.5

36.6

2.0

42.6

3204

500

24x3x2.5

0.7

0.5

40.9

2.1

47.1

3753

500

30x3x2.5

0.7

0.5

43.5

2.2

49.9

4444

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

217

KCI

RE-Y(St)YBY , PiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

218

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.2

6.8

1.3

10.2

164

1000

2x2x0.5

0.6

0.2

10.4

1.4

14.0

257

1000

3x2x0.5

0.6

0.2

11.0

1.4

14.6

295

1000

4x2x0.5

0.6

0.2

12.1

1.4

15.7

339

1000

5x2x0.5

0.6

0.2

13.2

1.4

16.8

385

1000

6x2x0.5

0.6

0.2

14.4

1.5

18.2

440

1000

7x2x0.5

0.6

0.2

14.4

1.5

18.2

466

1000

10x2x0.5

0.6

0.2

18.5

1.6

22.5

626

1000

12x2x0.5

0.6

0.2

19.2

1.6

23.2

690

1000

16x2x0.5

0.6

0.2

21.3

1.6

25.3

834

500

20x2x0.5

0.6

0.2

23.9

1.7

28.1

996

500

24x2x0.5

0.6

0.2

26.6

1.7

30.8

1151

500

30x2x0.5

0.6

0.2

28.3

1.8

32.7

1350

500

1x2x0.75

0.6

0.2

7.3

1.3

10.7

178

1000

2x2x0.75

0.6

0.2

11.1

1.4

14.7

284

1000

3x2x0.75

0.6

0.2

11.9

1.4

15.5

329

1000

4x2x0.75

0.6

0.2

13.0

1.4

16.6

382

1000

5x2x0.75

0.6

0.2

14.2

1.5

18.0

444

1000

6x2x0.75

0.6

0.2

15.6

1.5

19.4

501

1000

7x2x0.75

0.6

0.2

15.6

1.5

19.4

533

1000

10x2x0.75

0.6

0.2

20.0

1.6

24.0

721

1000

12x2x0.75

0.6

0.2

20.7

1.6

24.7

798

500

16x2x0.75

0.6

0.2

23.1

1.7

27.3

983

500

20x2x0.75

0.6

0.2

25.9

1.7

30.1

1166

500

24x2x0.75

0.6

0.2

28.9

1.8

33.3

1365

500

30x2x0.75

0.6

0.2

30.7

1.8

35.1

1594

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

219

KCI

RE-Y(St)YBY , PiMF

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.2

7.6

1.3

11.0

190

1000

2x2x1

0.6

0.2

11.8

1.4

15.4

307

1000

3x2x1

0.6

0.2

12.5

1.4

16.1

360

1000

4x2x1

0.6

0.2

13.8

1.4

17.4

420

1000

5x2x1

0.6

0.2

15.1

1.5

18.9

490

1000

6x2x1

0.6

0.2

16.5

1.5

20.3

555

1000

7x2x1

0.6

0.2

16.5

1.5

20.3

593

1000

10x2x1

0.6

0.2

21.3

1.6

25.3

806

500

12x2x1

0.6

0.2

22.0

1.6

26.0

897

500

16x2x1

0.6

0.2

24.6

1.7

28.8

1111

500

20x2x1

0.6

0.2

27.6

1.8

32.0

1335

500

24x2x1

0.6

0.2

30.8

1.8

35.2

1551

500

30x2x1

0.6

0.2

32.7

1.9

37.3

1835

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

220

1x2x1.5

0.6

0.2

8.2

1.3

11.6

214

1000

2x2x1.5

0.6

0.2

12.8

1.4

16.4

352

1000

3x2x1.5

0.6

0.2

13.7

1.5

17.5

426

1000

4x2x1.5

0.6

0.2

15.1

1.5

18.9

502

1000

5x2x1.5

0.6

0.2

16.5

1.5

20.3

580

1000

6x2x1.5

0.6

0.2

18.1

1.6

22.1

669

1000

7x2x1.5

0.6

0.2

18.1

1.6

22.1

720

1000

10x2x1.5

0.6

0.2

23.4

1.7

27.6

983

500

12x2x1.5

0.6

0.2

24.3

1.7

28.5

1101

500

16x2x1.5

0.6

0.2

27.1

1.8

31.5

1372

500

20x2x1.5

0.6

0.2

30.4

1.8

34.8

1641

500

24x2x1.5

0.6

0.2

34.4

1.9

39.0

1966

500

30x2x1.5

0.6

0.5

36.5

2.0

42.5

2774

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.2

9.5

1.4

13.1

266

1000

2x2x2.5

0.7

0.2

15.1

1.5

18.9

450

1000

3x2x2.5

0.7

0.2

16.1

1.5

19.9

544

1000

4x2x2.5

0.7

0.2

17.7

1.6

21.7

658

1000

5x2x2.5

0.7

0.2

19.5

1.6

23.5

767

1000

6x2x2.5

0.7

0.2

21.4

1.6

25.4

879

500

7x2x2.5

0.7

0.2

21.4

1.6

25.4

954

500

10x2x2.5

0.7

0.2

27.8

1.8

32.2

1325

500

12x2x2.5

0.7

0.2

28.8

1.8

33.2

1496

500

16x2x2.5

0.7

0.2

32.7

1.9

37.3

1915

500

20x2x2.5

0.7

0.5

36.7

2.0

42.7

2759

500

24x2x2.5

0.7

0.5

41.0

2.1

47.2

3218

500

30x2x2.5

0.7

0.5

43.6

2.2

50.0

3776

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

221

KCI

RE-Y(St)YBY , TiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

Instrument Cables

+70 oC

Conductor cross section

PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

222
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.2

7.2

1.3

10.6

179

1000

2x3x0.5

0.6

0.2

11.5

1.4

15.1

295

1000

3x3x0.5

0.6

0.2

12.2

1.4

15.8

343

1000

4x3x0.5

0.6

0.2

13.4

1.4

17.0

399

1000

5x3x0.5

0.6

0.2

14.7

1.5

18.5

465

1000

6x3x0.5

0.6

0.2

16.1

1.5

19.9

525

1000

7x3x0.5

0.6

0.2

16.1

1.5

19.9

560

1000

10x3x0.5

0.6

0.2

20.7

1.6

24.7

758

500

12x3x0.5

0.6

0.2

21.4

1.6

25.4

842

500

16x3x0.5

0.6

0.2

23.9

1.7

28.1

1039

500

20x3x0.5

0.6

0.2

26.8

1.7

31.0

1234

500

24x3x0.5

0.6

0.2

29.9

1.8

34.3

1446

500

30x3x0.5

0.6

0.2

31.8

1.9

36.4

1707

500

1x3x0.75

0.6

0.2

7.6

1.3

11.0

197

1000

2x3x0.75

0.6

0.2

12.3

1.4

15.9

330

1000

3x3x0.75

0.6

0.2

13.1

1.4

16.7

389

1000

4x3x0.75

0.6

0.2

14.4

1.5

18.2

464

1000

5x3x0.75

0.6

0.2

15.9

1.5

19.7

535

1000

6x3x0.75

0.6

0.2

17.4

1.5

21.2

607

1000

7x3x0.75

0.6

0.2

17.4

1.5

21.2

652

1000

10x3x0.75

0.6

0.2

22.4

1.7

26.6

898

500

12x3x0.75

0.6

0.2

23.2

1.7

27.4

1003

500

16x3x0.75

0.6

0.2

25.9

1.7

30.1

1233

500

20x3x0.75

0.6

0.2

29.1

1.8

33.5

1484

500

24x3x0.75

0.6

0.2

32.8

1.9

37.4

1779

500

30x3x0.75

0.6

0.2

34.9

1.9

39.5

2089

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

223

KCI

RE-Y(St)YBY , TiMF

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.2

8.0

1.3

11.4

212

1000

2x3x1

0.6

0.2

13.1

1.4

16.7

361

1000

3x3x1

0.6

0.2

13.9

1.5

17.7

437

1000

4x3x1

0.6

0.2

15.3

1.5

19.1

517

1000

5x3x1

0.6

0.2

16.8

1.5

20.6

598

1000

6x3x1

0.6

0.2

18.5

1.6

22.5

690

1000

7x3x1

0.6

0.2

18.5

1.6

22.5

745

1000

10x3x1

0.6

0.2

23.8

1.7

28.0

1017

500

12x3x1

0.6

0.2

24.7

1.7

28.9

1142

500

16x3x1

0.6

0.2

27.6

1.8

32.0

1425

500

20x3x1

0.6

0.2

31.0

1.8

35.4

1707

500

24x3x1

0.6

0.2

35.0

1.9

39.6

2046

500

30x3x1

0.6

0.5

37.2

2.0

43.2

2880

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

224

1x3x1.5

0.6

0.2

8.7

1.3

12.1

243

1000

2x3x1.5

0.6

0.2

14.3

1.5

18.1

428

1000

3x3x1.5

0.6

0.2

15.2

1.5

19.0

518

1000

4x3x1.5

0.6

0.2

16.8

1.5

20.6

619

1000

5x3x1.5

0.6

0.2

18.5

1.6

22.5

731

1000

6x3x1.5

0.6

0.2

20.3

1.6

24.3

837

1000

7x3x1.5

0.6

0.2

20.3

1.6

24.3

909

1000

10x3x1.5

0.6

0.2

26.3

1.7

30.5

1250

500

12x3x1.5

0.6

0.2

27.2

1.8

31.6

1426

500

16x3x1.5

0.6

0.2

30.5

1.8

34.9

1778

500

20x3x1.5

0.6

0.2

34.7

1.9

39.3

2194

500

24x3x1.5

0.6

0.5

38.7

2.1

44.9

3065

500

30x3x1.5

0.6

0.5

41.1

2.1

47.3

3580

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YBY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Tape
Thickness

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.2

10.0

1.4

13.6

309

1000

2x3x2.5

0.7

0.2

16.8

1.5

20.6

548

1000

3x3x2.5

0.7

0.2

18.0

1.6

22.0

686

1000

4x3x2.5

0.7

0.2

19.8

1.6

23.8

830

1000

5x3x2.5

0.7

0.2

21.9

1.7

26.1

987

500

6x3x2.5

0.7

0.2

24.1

1.7

28.3

1137

500

7x3x2.5

0.7

0.2

24.1

1.7

28.3

1245

500

10x3x2.5

0.7

0.2

31.3

1.9

35.9

1738

500

12x3x2.5

0.7

0.2

32.9

1.9

37.5

2014

500

16x3x2.5

0.7

0.5

36.8

2.0

42.8

2988

500

20x3x2.5

0.7

0.5

41.4

2.1

47.6

3589

500

24x3x2.5

0.7

0.5

46.6

2.3

53.2

4278

250

30x3x2.5

0.7

0.5

49.6

2.3

56.2

5030

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

225

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)YBY

Fire Resistant

EN 50288-7 (500 V)

RE-2X(St)YBY Multi-Core
RE-2X(St)YBY Multi-Pair
RE-2X(St)YRY Multi-Triple
RE-2X(St)YRY PiMF
RE-2X(St)YRY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH

Fire Resistant

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-2X(St)YBY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Mica-glass Tape + XLPE


Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Yellow or White (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

228
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.6

0.2

7.4

1.3

10.8

165

1000

3x0.5

0.6

0.2

7.9

1.3

11.3

181

1000

4x0.5

0.6

0.2

8.5

1.3

11.9

202

1000

5x0.5

0.6

0.2

9.3

1.3

12.7

224

1000

6x0.5

0.6

0.2

10.0

1.4

13.6

252

1000

7x0.5

0.6

0.2

10.0

1.4

13.6

261

1000

8x0.5

0.6

0.2

11.6

1.4

15.2

297

1000

10x0.5

0.6

0.2

12.6

1.4

16.2

334

1000

12x0.5

0.6

0.2

13.0

1.4

16.6

360

1000

16x0.5

0.6

0.2

14.4

1.4

18.0

422

1000

20x0.5

0.6

0.2

16.0

1.5

19.8

495

1000

24x0.5

0.6

0.2

17.8

1.5

21.6

563

1000

30x0.5

0.6

0.2

18.8

1.5

22.6

638

1000

2x0.75

0.6

0.2

7.9

1.3

11.3

178

1000

3x0.75

0.6

0.2

8.3

1.3

11.7

198

1000

4x0.75

0.6

0.2

9.0

1.3

12.4

223

1000

5x0.75

0.6

0.2

9.8

1.3

13.2

249

1000

6x0.75

0.6

0.2

10.7

1.4

14.3

281

1000

7x0.75

0.6

0.2

10.7

1.4

14.3

294

1000

8x0.75

0.6

0.2

12.3

1.4

15.9

335

1000

10x0.75

0.6

0.2

13.4

1.4

17.0

379

1000

12x0.75

0.6

0.2

13.9

1.4

17.5

412

1000

16x0.75

0.6

0.2

15.4

1.5

19.2

495

1000

20x0.75

0.6

0.2

17.2

1.5

21.0

575

1000

24x0.75

0.6

0.2

19.0

1.5

22.8

658

1000

30x0.75

0.6

0.2

20.2

1.6

24.2

762

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

229

KCI

RE-2X(St)YRY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.2

8.2

1.3

11.6

190

1000

3x1

0.6

0.2

8.7

1.3

12.1

213

1000

4x1

0.6

0.2

9.5

1.3

12.9

242

1000

5x1

0.6

0.2

10.3

1.4

13.9

277

1000

6x1

0.6

0.2

11.2

1.4

14.8

307

1000

7x1

0.6

0.2

11.2

1.4

14.8

323

1000

8x1

0.6

0.2

13.0

1.4

16.6

369

1000

10x1

0.6

0.2

14.2

1.4

17.8

420

1000

12x1

0.6

0.2

14.6

1.4

18.2

459

1000

16x1

0.6

0.2

16.2

1.5

20.0

555

1000

20x1

0.6

0.2

18.1

1.5

21.9

649

1000

24x1

0.6

0.2

20.1

1.6

24.1

755

1000

30x1

0.6

0.2

21.3

1.6

25.3

868

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

230

2x1.5

0.6

0.2

8.8

1.3

12.2

212

1000

3x1.5

0.6

0.2

9.4

1.3

12.8

242

1000

4x1.5

0.6

0.2

10.2

1.4

13.8

283

1000

5x1.5

0.6

0.2

11.1

1.4

14.7

320

1000

6x1.5

0.6

0.2

12.1

1.4

15.7

358

1000

7x1.5

0.6

0.2

12.1

1.4

15.7

379

1000

8x1.5

0.6

0.2

14.1

1.4

17.7

435

1000

10x1.5

0.6

0.2

15.4

1.5

19.2

507

1000

12x1.5

0.6

0.2

15.9

1.5

19.7

558

1000

16x1.5

0.6

0.2

17.7

1.5

21.5

673

1000

20x1.5

0.6

0.2

19.7

1.6

23.7

803

1000

24x1.5

0.6

0.2

21.9

1.6

25.9

926

500

30x1.5

0.6

0.2

23.2

1.6

27.2

1076

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

0.2

10.1

1.4

13.7

262

1000

3x2.5

0.7

0.2

10.7

1.4

14.3

305

1000

4x2.5

0.7

0.2

11.7

1.4

15.3

354

1000

5x2.5

0.7

0.2

12.8

1.4

16.4

405

1000

6x2.5

0.7

0.2

14.0

1.4

17.6

457

1000

7x2.5

0.7

0.2

14.0

1.4

17.6

489

1000

8x2.5

0.7

0.2

16.3

1.5

20.1

570

1000

10x2.5

0.7

0.2

17.8

1.5

21.6

661

1000

12x2.5

0.7

0.2

18.5

1.5

22.3

736

1000

16x2.5

0.7

0.2

20.6

1.6

24.6

910

500

20x2.5

0.7

0.2

23.0

1.6

27.0

1082

500

24x2.5

0.7

0.2

25.6

1.7

29.8

1267

500

30x2.5

0.7

0.2

27.2

1.7

31.4

1487

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

231

KCI

RE-2X(St)YBY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

IEC 60708 Full color

Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

232
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.2

7.4

1.3

10.8

165

1000

2x2x0.5

0.6

0.2

10.8

1.4

14.4

246

1000

3x2x0.5

0.6

0.2

11.4

1.4

15.0

277

1000

4x2x0.5

0.6

0.2

12.5

1.4

16.1

315

1000

5x2x0.5

0.6

0.2

13.7

1.4

17.3

355

1000

6x2x0.5

0.6

0.2

15.0

1.5

18.8

403

1000

7x2x0.5

0.6

0.2

15.0

1.5

18.8

423

1000

10x2x0.5

0.6

0.2

19.2

1.5

23.0

555

1000

12x2x0.5

0.6

0.2

19.9

1.6

23.9

614

1000

16x2x0.5

0.6

0.2

22.2

1.6

26.2

732

500

20x2x0.5

0.6

0.2

24.8

1.7

29.0

867

500

24x2x0.5

0.6

0.2

27.7

1.7

31.9

996

500

30x2x0.5

0.6

0.2

29.4

1.7

33.6

1143

500

1x2x0.75

0.6

0.2

7.9

1.3

11.3

179

1000

2x2x0.75

0.6

0.2

11.4

1.4

15.0

271

1000

3x2x0.75

0.6

0.2

12.2

1.4

15.8

309

1000

4x2x0.75

0.6

0.2

13.4

1.4

17.0

355

1000

5x2x0.75

0.6

0.2

14.6

1.5

18.4

410

1000

6x2x0.75

0.6

0.2

16.0

1.5

19.8

459

1000

7x2x0.75

0.6

0.2

16.0

1.5

19.8

484

1000

10x2x0.75

0.6

0.2

20.6

1.6

24.6

651

500

12x2x0.75

0.6

0.2

21.3

1.6

25.3

714

500

16x2x0.75

0.6

0.2

23.8

1.6

27.8

860

500

20x2x0.75

0.6

0.2

26.7

1.7

30.9

1024

500

24x2x0.75

0.6

0.2

29.7

1.8

34.1

1194

500

30x2x0.75

0.6

0.2

31.6

1.8

36.0

1380

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

233

KCI

RE-2X(St)YRY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.2

8.2

1.3

11.6

191

1000

2x2x1

0.6

0.2

12.0

1.4

15.6

293

1000

3x2x1

0.6

0.2

12.8

1.4

16.4

337

1000

4x2x1

0.6

0.2

14.1

1.4

17.7

390

1000

5x2x1

0.6

0.2

15.4

1.5

19.2

452

1000

6x2x1

0.6

0.2

16.9

1.5

20.7

509

1000

7x2x1

0.6

0.2

16.9

1.5

20.7

541

1000

10x2x1

0.6

0.2

21.8

1.6

25.8

730

500

12x2x1

0.6

0.2

22.6

1.6

26.6

806

500

16x2x1

0.6

0.2

25.2

1.7

29.4

989

500

20x2x1

0.6

0.2

28.2

1.7

32.4

1170

500

24x2x1

0.6

0.2

31.5

1.8

35.9

1367

500

30x2x1

0.6

0.2

33.5

1.8

37.9

1591

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

234

1x2x1.5

0.6

0.2

8.8

1.3

12.2

213

1000

2x2x1.5

0.6

0.2

13.0

1.4

16.6

334

1000

3x2x1.5

0.6

0.2

13.9

1.4

17.5

392

1000

4x2x1.5

0.6

0.2

15.3

1.5

19.1

467

1000

5x2x1.5

0.6

0.2

16.8

1.5

20.6

536

1000

6x2x1.5

0.6

0.2

18.4

1.5

22.2

607

1000

7x2x1.5

0.6

0.2

18.4

1.5

22.2

650

1000

10x2x1.5

0.6

0.2

23.7

1.6

27.7

884

500

12x2x1.5

0.6

0.2

24.6

1.7

28.8

996

500

16x2x1.5

0.6

0.2

27.5

1.7

31.7

1221

500

20x2x1.5

0.6

0.2

30.9

1.8

35.3

1467

500

24x2x1.5

0.6

0.2

34.5

1.9

39.1

1720

500

30x2x1.5

0.6

0.2

37.1

1.9

41.7

2059

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.2

10.1

1.4

13.7

263

1000

2x2x2.5

0.7

0.2

15.0

1.5

18.8

424

1000

3x2x2.5

0.7

0.2

16.1

1.5

19.9

506

1000

4x2x2.5

0.7

0.2

17.7

1.5

21.5

601

1000

5x2x2.5

0.7

0.2

19.5

1.6

23.5

707

1000

6x2x2.5

0.7

0.2

21.4

1.6

25.4

807

500

7x2x2.5

0.7

0.2

21.4

1.6

25.4

871

500

10x2x2.5

0.7

0.2

27.8

1.8

32.2

1207

500

12x2x2.5

0.7

0.2

28.8

1.8

33.2

1356

500

16x2x2.5

0.7

0.2

32.3

1.9

36.9

1694

500

20x2x2.5

0.7

0.2

36.7

2.0

41.5

2086

500

24x2x2.5

0.7

0.5

41.0

2.1

47.2

2941

500

30x2x2.5

0.7

0.5

43.6

2.1

49.8

3413

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

235

KCI

RE-2X(St)YBY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Tapes
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

IEC 60331

Instrument Cables

Criteria
Conductor cross section

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

236
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.2

7.9

1.3

11.3

182

1000

2x3x0.5

0.6

0.2

11.9

1.4

15.5

286

1000

3x3x0.5

0.6

0.2

12.7

1.4

16.3

328

1000

4x3x0.5

0.6

0.2

14.0

1.4

17.6

378

1000

5x3x0.5

0.6

0.2

15.3

1.5

19.1

438

1000

6x3x0.5

0.6

0.2

16.7

1.5

20.5

492

1000

7x3x0.5

0.6

0.2

16.7

1.5

20.5

521

1000

10x3x0.5

0.6

0.2

21.6

1.6

25.6

702

500

12x3x0.5

0.6

0.2

22.3

1.6

26.3

773

500

16x3x0.5

0.6

0.2

24.9

1.7

29.1

946

500

20x3x0.5

0.6

0.2

28.0

1.7

32.2

1117

500

24x3x0.5

0.6

0.2

31.2

1.8

35.6

1304

500

30x3x0.5

0.6

0.2

33.2

1.8

37.6

1513

500

1x3x0.75

0.6

0.2

8.3

1.3

11.7

199

1000

2x3x0.75

0.6

0.2

12.7

1.4

16.3

319

1000

3x3x0.75

0.6

0.2

13.5

1.4

17.1

371

1000

4x3x0.75

0.6

0.2

14.9

1.5

18.7

439

1000

5x3x0.75

0.6

0.2

16.4

1.5

20.2

503

1000

6x3x0.75

0.6

0.2

17.9

1.5

21.7

569

1000

7x3x0.75

0.6

0.2

17.9

1.5

21.7

607

1000

10x3x0.75

0.6

0.2

23.1

1.6

27.1

823

500

12x3x0.75

0.6

0.2

24.0

1.6

28.0

913

500

16x3x0.75

0.6

0.2

26.8

1.7

31.0

1127

500

20x3x0.75

0.6

0.2

30.1

1.8

34.5

1351

500

24x3x0.75

0.6

0.2

33.6

1.8

38.0

1568

500

30x3x0.75

0.6

0.2

36.1

1.9

40.7

1889

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

237

KCI

RE-2X(St)YBY

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.2

8.7

1.3

12.1

214

1000

2x3x1

0.6

0.2

13.4

1.4

17.0

347

1000

3x3x1

0.6

0.2

14.3

1.4

17.9

409

1000

4x3x1

0.6

0.2

15.7

1.5

19.5

489

1000

5x3x1

0.6

0.2

17.3

1.5

21.1

563

1000

6x3x1

0.6

0.2

18.9

1.5

22.7

639

1000

7x3x1

0.6

0.2

18.9

1.5

22.7

686

1000

10x3x1

0.6

0.2

24.5

1.6

28.5

934

500

12x3x1

0.6

0.2

25.4

1.7

29.6

1055

500

16x3x1

0.6

0.2

28.4

1.7

32.6

1296

500

20x3x1

0.6

0.2

31.9

1.8

36.3

1561

500

24x3x1

0.6

0.2

35.6

1.9

40.2

1831

500

30x3x1

0.6

0.2

38.3

1.9

42.9

2196

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

238

1x3x1.5

0.6

0.2

9.4

1.3

12.8

244

1000

2x3x1.5

0.6

0.2

14.5

1.5

18.3

410

1000

3x3x1.5

0.6

0.2

15.5

1.5

19.3

492

1000

4x3x1.5

0.6

0.2

17.1

1.5

20.9

584

1000

5x3x1.5

0.6

0.2

18.8

1.5

22.6

679

1000

6x3x1.5

0.6

0.2

20.6

1.6

24.6

785

500

7x3x1.5

0.6

0.2

20.6

1.6

24.6

849

500

10x3x1.5

0.6

0.2

26.7

1.7

30.9

1164

500

12x3x1.5

0.6

0.2

27.7

1.7

31.9

1310

500

16x3x1.5

0.6

0.2

31.0

1.8

35.4

1640

500

20x3x1.5

0.6

0.2

35.3

1.9

39.9

2022

500

24x3x1.5

0.6

0.5

39.3

2.0

45.3

2849

500

30x3x1.5

0.6

0.5

41.9

2.1

48.1

3330

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.2

10.7

1.4

14.3

307

1000

2x3x2.5

0.7

0.2

16.8

1.5

20.6

520

1000

3x3x2.5

0.7

0.2

18.0

1.5

21.8

638

1000

4x3x2.5

0.7

0.2

19.9

1.6

23.9

778

1000

5x3x2.5

0.7

0.2

21.9

1.6

25.9

912

500

6x3x2.5

0.7

0.2

24.1

1.7

28.3

1060

500

7x3x2.5

0.7

0.2

24.1

1.7

28.3

1157

500

10x3x2.5

0.7

0.2

31.4

1.8

35.8

1598

500

12x3x2.5

0.7

0.2

32.5

1.9

37.1

1827

500

16x3x2.5

0.7

0.2

36.8

2.0

41.6

2347

500

20x3x2.5

0.7

0.5

41.4

2.1

47.6

3343

500

24x3x2.5

0.7

0.5

46.3

2.2

52.7

3908

250

30x3x2.5

0.7

0.5

49.7

2.3

56.3

4665

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

239

KCI

RE-2X(St)YBY , PiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

IEC 60708 Full color

Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

240
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.2

7.8

1.3

11.2

180

1000

2x2x0.5

0.6

0.2

12.1

1.4

15.7

288

1000

3x2x0.5

0.6

0.2

12.9

1.4

16.5

329

1000

4x2x0.5

0.6

0.2

14.2

1.4

17.8

380

1000

5x2x0.5

0.6

0.2

15.5

1.5

19.3

439

1000

6x2x0.5

0.6

0.2

17.0

1.5

20.8

493

1000

7x2x0.5

0.6

0.2

17.0

1.5

20.8

521

1000

10x2x0.5

0.6

0.2

21.9

1.6

25.9

702

500

12x2x0.5

0.6

0.2

22.7

1.6

26.7

772

500

16x2x0.5

0.6

0.2

25.4

1.7

29.6

943

500

20x2x0.5

0.6

0.2

28.4

1.7

32.6

1112

500

24x2x0.5

0.6

0.2

31.7

1.8

36.1

1297

500

30x2x0.5

0.6

0.2

33.7

1.8

38.1

1503

500

1x2x0.75

0.6

0.2

8.2

1.3

11.6

194

1000

2x2x0.75

0.6

0.2

12.8

1.4

16.4

314

1000

3x2x0.75

0.6

0.2

13.7

1.4

17.3

364

1000

4x2x0.75

0.6

0.2

15.1

1.5

18.9

429

1000

5x2x0.75

0.6

0.2

16.5

1.5

20.3

490

1000

6x2x0.75

0.6

0.2

18.1

1.5

21.9

553

1000

7x2x0.75

0.6

0.2

18.1

1.5

21.9

587

1000

10x2x0.75

0.6

0.2

23.4

1.6

27.4

794

500

12x2x0.75

0.6

0.2

24.3

1.7

28.5

889

500

16x2x0.75

0.6

0.2

27.1

1.7

31.3

1079

500

20x2x0.75

0.6

0.2

30.4

1.8

34.8

1291

500

24x2x0.75

0.6

0.2

34.0

1.9

38.6

1509

500

30x2x0.75

0.6

0.2

36.5

1.9

41.1

1797

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

241

KCI

RE-2X(St)YBY , PiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.2

8.6

1.3

12.0

206

1000

2x2x1

0.6

0.2

13.5

1.4

17.1

337

1000

3x2x1

0.6

0.2

14.4

1.4

18.0

393

1000

4x2x1

0.6

0.2

15.8

1.5

19.6

467

1000

5x2x1

0.6

0.2

17.4

1.5

21.2

535

1000

6x2x1

0.6

0.2

19.1

1.5

22.9

606

1000

7x2x1

0.6

0.2

19.1

1.5

22.9

646

1000

10x2x1

0.6

0.2

24.7

1.7

28.9

889

500

12x2x1

0.6

0.2

25.6

1.7

29.8

986

500

16x2x1

0.6

0.2

28.6

1.7

32.8

1204

500

20x2x1

0.6

0.2

32.1

1.8

36.5

1445

500

24x2x1

0.6

0.2

36.3

1.9

40.9

1732

500

30x2x1

0.6

0.2

38.6

1.9

43.2

2022

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

242

1x2x1.5

0.6

0.2

9.2

1.3

12.6

230

1000

2x2x1.5

0.6

0.2

14.6

1.5

18.4

389

1000

3x2x1.5

0.6

0.2

15.5

1.5

19.3

459

1000

4x2x1.5

0.6

0.2

17.1

1.5

20.9

540

1000

5x2x1.5

0.6

0.2

18.9

1.5

22.7

623

1000

6x2x1.5

0.6

0.2

20.7

1.6

24.7

718

500

7x2x1.5

0.6

0.2

20.7

1.6

24.7

771

500

10x2x1.5

0.6

0.2

26.8

1.7

31.0

1052

500

12x2x1.5

0.6

0.2

27.8

1.7

32.0

1176

500

16x2x1.5

0.6

0.2

31.1

1.8

35.5

1461

500

20x2x1.5

0.6

0.2

35.4

1.9

40.0

1798

500

24x2x1.5

0.6

0.5

39.5

2.0

45.5

2581

500

30x2x1.5

0.6

0.5

42.0

2.1

48.2

2995

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.2

10.4

1.4

14.0

281

1000

2x2x2.5

0.7

0.2

16.8

1.5

20.6

477

1000

3x2x2.5

0.7

0.2

17.9

1.5

21.7

573

1000

4x2x2.5

0.7

0.2

19.8

1.6

23.8

692

1000

5x2x2.5

0.7

0.2

21.8

1.6

25.8

805

500

6x2x2.5

0.7

0.2

24.0

1.7

28.2

931

500

7x2x2.5

0.7

0.2

24.0

1.7

28.2

1006

500

10x2x2.5

0.7

0.2

31.2

1.8

35.6

1382

500

12x2x2.5

0.7

0.2

32.4

1.9

37.0

1570

500

16x2x2.5

0.7

0.2

36.7

2.0

41.5

2003

500

20x2x2.5

0.7

0.5

41.3

2.1

47.5

2912

500

24x2x2.5

0.7

0.5

46.1

2.2

52.5

3391

250

30x2x2.5

0.7

0.5

49.5

2.3

56.1

4019

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

243

KCI

RE-2X(St)YBY , TiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Conductor cross section

Mica-glass Tape + XLPE


Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC

IEC 60331

Criteria

Blue,White,Red (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

244
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Tape
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.2

8.2

1.3

11.6

197

1000

2x3x0.5

0.6

0.2

13.4

1.4

17.0

331

1000

3x3x0.5

0.6

0.2

14.3

1.4

17.9

384

1000

4x3x0.5

0.6

0.2

15.8

1.5

19.6

455

1000

5x3x0.5

0.6

0.2

17.3

1.5

21.1

520

1000

6x3x0.5

0.6

0.2

19.0

1.5

22.8

588

1000

7x3x0.5

0.6

0.2

19.0

1.5

22.8

626

1000

10x3x0.5

0.6

0.2

24.6

1.7

28.8

859

500

12x3x0.5

0.6

0.2

25.5

1.7

29.7

951

500

16x3x0.5

0.6

0.2

28.5

1.7

32.7

1159

500

20x3x0.5

0.6

0.2

32.0

1.8

36.4

1388

500

24x3x0.5

0.6

0.2

36.1

1.9

40.7

1664

500

30x3x0.5

0.6

0.2

38.4

1.9

43.0

1937

500

1x3x0.75

0.6

0.2

8.7

1.3

12.1

215

1000

2x3x0.75

0.6

0.2

14.3

1.4

17.9

365

1000

3x3x0.75

0.6

0.2

15.2

1.5

19.0

437

1000

4x3x0.75

0.6

0.2

16.8

1.5

20.6

512

1000

5x3x0.75

0.6

0.2

18.5

1.5

22.3

589

1000

6x3x0.75

0.6

0.2

20.3

1.6

24.3

678

1000

7x3x0.75

0.6

0.2

20.3

1.6

24.3

725

1000

10x3x0.75

0.6

0.2

26.3

1.7

30.5

987

500

12x3x0.75

0.6

0.2

27.2

1.7

31.4

1099

500

16x3x0.75

0.6

0.2

30.5

1.8

34.9

1362

500

20x3x0.75

0.6

0.2

34.3

1.9

38.9

1636

500

24x3x0.75

0.6

0.2

38.7

2.0

43.5

1960

500

30x3x0.75

0.6

0.5

41.1

2.0

47.1

2786

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

245

KCI

RE-2X(St)YBY , TiMF

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.2

9.1

1.3

12.5

230

1000

2x3x1

0.6

0.2

15.0

1.5

18.8

403

1000

3x3x1

0.6

0.2

16.0

1.5

19.8

477

1000

4x3x1

0.6

0.2

17.7

1.5

21.5

563

1000

5x3x1

0.6

0.2

19.5

1.5

23.3

651

1000

6x3x1

0.6

0.2

21.4

1.6

25.4

751

500

7x3x1

0.6

0.2

21.4

1.6

25.4

808

500

10x3x1

0.6

0.2

27.7

1.7

31.9

1104

500

12x3x1

0.6

0.2

28.8

1.7

33.0

1236

500

16x3x1

0.6

0.2

32.2

1.8

36.6

1539

500

20x3x1

0.6

0.2

36.6

1.9

41.2

1895

500

24x3x1

0.6

0.5

40.9

2.0

46.9

2711

500

30x3x1

0.6

0.5

43.5

2.1

49.7

3151

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

246

1x3x1.5

0.6

0.2

9.7

1.4

13.3

266

1000

2x3x1.5

0.6

0.2

16.2

1.5

20.0

462

1000

3x3x1.5

0.6

0.2

17.3

1.5

21.1

556

1000

4x3x1.5

0.6

0.2

19.2

1.6

23.2

672

1000

5x3x1.5

0.6

0.2

21.1

1.6

25.1

782

500

6x3x1.5

0.6

0.2

23.2

1.6

27.2

895

500

7x3x1.5

0.6

0.2

23.2

1.6

27.2

969

500

10x3x1.5

0.6

0.2

30.2

1.8

34.6

1345

500

12x3x1.5

0.6

0.2

31.3

1.8

35.7

1515

500

16x3x1.5

0.6

0.2

35.4

1.9

40.0

1937

500

20x3x1.5

0.6

0.5

39.8

2.0

45.8

2817

500

24x3x1.5

0.6

0.5

44.5

2.1

50.7

3282

250

30x3x1.5

0.6

0.5

47.4

2.2

53.8

3840

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YBY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

mm

Overall
Diameter

Diameter Under
Armour

mm2

Sheath thickness

Nominal cross section


area of conductor

Armour Wire
Diameter

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.2

11.1

1.4

14.7

325

1000

2x3x2.5

0.7

0.2

18.7

1.6

22.7

587

1000

3x3x2.5

0.7

0.2

20.1

1.6

24.1

719

1000

4x3x2.5

0.7

0.2

22.2

1.6

26.2

867

500

5x3x2.5

0.7

0.2

24.5

1.7

28.7

1029

500

6x3x2.5

0.7

0.2

27.0

1.7

31.2

1183

500

7x3x2.5

0.7

0.2

27.0

1.7

31.2

1292

500

10x3x2.5

0.7

0.2

35.6

1.9

40.2

1840

500

12x3x2.5

0.7

0.2

36.9

2.0

41.7

2099

500

16x3x2.5

0.7

0.5

41.4

2.1

47.6

3137

500

20x3x2.5

0.7

0.5

46.9

2.2

53.3

3813

250

24x3x2.5

0.7

0.5

52.5

2.3

59.1

4454

250

30x3x2.5

0.7

0.5

55.8

2.4

62.6

5242

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HBH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

247

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-Y(St)YKYRY

EN 50288-7 (500 V)

RE-Y(St)YKYRY Multi-Core
RE-Y(St)YKYRY Multi-Pair
RE-Y(St)YKYRY Multi-Triple
RE-Y(St)YKYRY PiMF
RE-Y(St)YKYRY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-Y(St)YKYRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

250

PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Yellow or White (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.6

0.9

8.3

0.9

8.5

1.4

13.1

525

1000

3x0.5

0.6

0.9

8.6

0.9

8.8

1.4

13.4

552

1000

4x0.5

0.6

0.9

9.2

0.9

9.4

1.4

14.0

593

1000

5x0.5

0.6

0.9

9.8

0.9

10.0

1.4

14.6

635

1000

6x0.5

0.6

0.9

10.4

0.9

10.6

1.4

15.2

679

1000

7x0.5

0.6

0.9

10.4

0.9

10.6

1.4

15.2

687

1000

8x0.5

0.6

1.0

11.8

0.9

11.8

1.4

16.4

802

1000

10x0.5

0.6

1.0

12.7

0.9

12.7

1.5

17.5

878

1000

12x0.5

0.6

1.0

13.0

0.9

13.0

1.5

17.8

914

1000

16x0.5

0.6

1.0

14.2

0.9

14.2

1.5

19.0

1013

1000

20x0.5

0.6

1.0

15.5

0.9

15.5

1.5

20.3

1129

1000

24x0.5

0.6

1.1

17.1

0.9

16.9

1.6

21.9

1304

1000

30x0.5

0.6

1.1

17.9

1.25

17.7

1.6

23.4

1552

1000

2x0.75

0.6

0.9

8.7

0.9

8.9

1.4

13.5

556

1000

3x0.75

0.6

0.9

9.1

0.9

9.3

1.4

13.9

587

1000

4x0.75

0.6

0.9

9.7

0.9

9.9

1.4

14.5

633

1000

5x0.75

0.6

0.9

10.3

0.9

10.5

1.4

15.1

681

1000

6x0.75

0.6

0.9

11.0

0.9

11.2

1.4

15.8

736

1000

7x0.75

0.6

0.9

11.0

0.9

11.2

1.4

15.8

747

1000

8x0.75

0.6

1.0

12.6

0.9

12.6

1.5

17.4

881

1000

10x0.75

0.6

1.0

13.5

0.9

13.5

1.5

18.3

959

1000

12x0.75

0.6

1.0

13.9

0.9

13.9

1.5

18.7

1009

1000

16x0.75

0.6

1.0

15.1

0.9

15.1

1.5

19.9

1130

1000

20x0.75

0.6

1.1

16.8

0.9

16.6

1.6

21.6

1319

1000

24x0.75

0.6

1.1

18.3

1.25

18.1

1.6

23.8

1609

1000

30x0.75

0.6

1.1

19.3

1.25

19.1

1.6

24.8

1743

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

251

KCI

RE-Y(St)YKYRY
Diameter Under
Armour

mm

mm

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.9

9.1

0.9

9.3

1.4

13.9

577

1000

3x1

0.6

0.9

9.5

0.9

9.7

1.4

14.3

618

1000

4x1

0.6

0.9

10.1

0.9

10.3

1.4

14.9

668

1000

5x1

0.6

0.9

10.8

0.9

11.0

1.4

15.6

720

1000

6x1

0.6

1.0

11.8

0.9

11.8

1.4

16.4

810

1000

7x1

0.6

1.0

11.8

0.9

11.8

1.4

16.4

825

1000

8x1

0.6

1.0

13.3

0.9

13.3

1.5

18.1

935

1000

10x1

0.6

1.0

14.2

0.9

14.2

1.5

19.0

1027

1000

12x1

0.6

1.0

14.6

0.9

14.6

1.5

19.4

1078

1000

16x1

0.6

1.1

16.2

0.9

16.0

1.5

20.8

1262

1000

20x1

0.6

1.1

17.8

1.25

17.6

1.6

23.3

1562

1000

24x1

0.6

1.1

19.4

1.25

19.2

1.6

24.9

1737

1000

30x1

0.6

1.2

20.6

1.25

20.2

1.7

26.1

1972

1000

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

252

2x1.5

0.6

0.9

9.7

0.9

9.9

1.4

14.5

628

1000

3x1.5

0.6

0.9

10.1

0.9

10.3

1.4

14.9

676

1000

4x1.5

0.6

0.9

10.8

0.9

11.0

1.4

15.6

736

1000

5x1.5

0.6

1.0

11.8

0.9

11.8

1.4

16.4

840

1000

6x1.5

0.6

1.0

12.7

0.9

12.7

1.5

17.5

914

1000

7x1.5

0.6

1.0

12.7

0.9

12.7

1.5

17.5

934

1000

8x1.5

0.6

1.0

14.3

0.9

14.3

1.5

19.1

1058

1000

10x1.5

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1167

1000

12x1.5

0.6

1.1

16.1

0.9

15.9

1.5

20.7

1282

1000

16x1.5

0.6

1.1

17.6

1.25

17.4

1.6

23.1

1604

1000

20x1.5

0.6

1.1

19.4

1.25

19.2

1.6

24.9

1807

1000

24x1.5

0.6

1.2

21.4

1.25

21.0

1.7

26.9

2101

1000

30x1.5

0.6

1.2

22.6

1.25

22.2

1.7

28.1

2300

1000

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

0.9

10.9

0.9

11.1

1.4

15.7

727

1000

3x2.5

0.7

1.0

11.7

0.9

11.7

1.4

16.3

828

1000

4x2.5

0.7

1.0

12.5

0.9

12.5

1.5

17.3

921

1000

5x2.5

0.7

1.0

13.5

0.9

13.5

1.5

18.3

1010

1000

6x2.5

0.7

1.0

14.5

0.9

14.5

1.5

19.3

1108

1000

7x2.5

0.7

1.0

14.5

0.9

14.5

1.5

19.3

1140

1000

8x2.5

0.7

1.1

16.8

0.9

16.6

1.6

21.6

1353

1000

10x2.5

0.7

1.1

18.1

1.25

17.9

1.6

23.6

1643

1000

12x2.5

0.7

1.1

18.7

1.25

18.5

1.6

24.2

1753

1000

16x2.5

0.7

1.2

20.7

1.25

20.3

1.7

26.2

2082

1000

20x2.5

0.7

1.2

22.9

1.25

22.5

1.7

28.4

2368

1000

24x2.5

0.7

1.3

25.3

1.25

24.7

1.8

30.8

2751

500

30x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

3057

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

253

KCI

RE-Y(St)YKYRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

254

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

8.3

0.9

8.5

1.4

13.1

526

1000

2x2x0.5

0.6

0.9

11.0

0.9

11.2

1.4

15.8

695

1000

3x2x0.5

0.6

1.0

11.7

0.9

11.7

1.4

16.3

775

1000

4x2x0.5

0.6

1.0

12.6

0.9

12.6

1.5

17.4

853

1000

5x2x0.5

0.6

1.0

13.6

0.9

13.6

1.5

18.4

927

1000

6x2x0.5

0.6

1.0

14.6

0.9

14.6

1.5

19.4

1010

1000

7x2x0.5

0.6

1.0

14.6

0.9

14.6

1.5

19.4

1027

1000

10x2x0.5

0.6

1.1

18.3

1.25

18.1

1.6

23.8

1492

1000

12x2x0.5

0.6

1.1

18.8

1.25

18.6

1.6

24.3

1563

1000

16x2x0.5

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1830

1000

20x2x0.5

0.6

1.2

23.0

1.25

22.6

1.7

28.5

2057

1000

24x2x0.5

0.6

1.3

25.6

1.25

25.0

1.8

31.1

2387

500

30x2x0.5

0.6

1.3

27.0

1.25

26.4

1.8

32.5

2597

500

1x2x0.75

0.6

0.9

8.7

0.9

8.9

1.4

13.5

556

1000

2x2x0.75

0.6

1.0

11.9

0.9

11.9

1.4

16.5

786

1000

3x2x0.75

0.6

1.0

12.5

0.9

12.5

1.5

17.3

853

1000

4x2x0.75

0.6

1.0

13.5

0.9

13.5

1.5

18.3

935

1000

5x2x0.75

0.6

1.0

14.5

0.9

14.5

1.5

19.3

1025

1000

6x2x0.75

0.6

1.1

15.9

0.9

15.7

1.5

20.5

1161

1000

7x2x0.75

0.6

1.1

15.9

0.9

15.7

1.5

20.5

1185

1000

10x2x0.75

0.6

1.1

19.6

1.25

19.4

1.6

25.1

1657

1000

12x2x0.75

0.6

1.2

20.4

1.25

20.0

1.7

25.9

1814

1000

16x2x0.75

0.6

1.2

22.5

1.25

22.1

1.7

28.0

2061

1000

20x2x0.75

0.6

1.3

25.1

1.25

24.5

1.8

30.6

2420

500

24x2x0.75

0.6

1.3

27.6

1.25

27.0

1.8

33.1

2709

500

30x2x0.75

0.6

1.4

29.4

1.25

28.6

1.8

34.7

3051

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

255

KCI

RE-Y(St)YKYRY
Diameter Under
Armour

mm

mm

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

9.1

0.9

9.3

1.4

13.9

578

1000

2x2x1

0.6

1.0

12.5

0.9

12.5

1.5

17.3

833

1000

3x2x1

0.6

1.0

13.1

0.9

13.1

1.5

17.9

901

1000

4x2x1

0.6

1.0

14.2

0.9

14.2

1.5

19.0

991

1000

5x2x1

0.6

1.0

15.3

0.9

15.3

1.5

20.1

1090

1000

6x2x1

0.6

1.1

16.7

0.9

16.5

1.5

21.3

1242

1000

7x2x1

0.6

1.1

16.7

0.9

16.5

1.5

21.3

1272

1000

10x2x1

0.6

1.2

21.0

1.25

20.6

1.7

26.5

1859

1000

12x2x1

0.6

1.2

21.7

1.25

21.3

1.7

27.2

1960

1000

16x2x1

0.6

1.2

23.9

1.25

23.5

1.7

29.4

2237

500

20x2x1

0.6

1.3

26.7

1.25

26.1

1.8

32.2

2631

500

24x2x1

0.6

1.4

29.6

1.25

28.8

1.8

34.9

3047

500

30x2x1

0.6

1.4

31.3

1.6

30.5

1.9

37.5

3599

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

256

1x2x1.5

0.6

0.9

9.7

0.9

9.9

1.4

14.5

628

1000

2x2x1.5

0.6

1.0

13.4

0.9

13.4

1.5

18.2

923

1000

3x2x1.5

0.6

1.0

14.2

0.9

14.2

1.5

19.0

1007

1000

4x2x1.5

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1121

1000

5x2x1.5

0.6

1.1

16.8

0.9

16.6

1.6

21.6

1298

1000

6x2x1.5

0.6

1.1

18.2

1.25

18.0

1.6

23.7

1565

1000

7x2x1.5

0.6

1.1

18.2

1.25

18.0

1.6

23.7

1607

1000

10x2x1.5

0.6

1.2

23.0

1.25

22.6

1.7

28.5

2134

1000

12x2x1.5

0.6

1.2

23.7

1.25

23.3

1.7

29.2

2274

500

16x2x1.5

0.6

1.3

26.4

1.25

25.8

1.8

31.9

2715

500

20x2x1.5

0.6

1.4

29.5

1.25

28.7

1.9

35.0

3205

500

24x2x1.5

0.6

1.4

32.5

1.6

31.7

1.9

38.7

3843

500

30x2x1.5

0.6

1.5

34.6

1.6

34.0

2.0

41.2

4434

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

10.9

0.9

11.1

1.4

15.7

728

1000

2x2x2.5

0.7

1.1

15.7

0.9

15.5

1.5

20.3

1153

1000

3x2x2.5

0.7

1.1

16.6

0.9

16.4

1.6

21.4

1284

1000

4x2x2.5

0.7

1.1

18.0

1.25

17.8

1.6

23.5

1580

1000

5x2x2.5

0.7

1.2

19.8

1.25

19.4

1.7

25.3

1830

1000

6x2x2.5

0.7

1.2

21.5

1.25

21.1

1.7

27.0

2020

1000

7x2x2.5

0.7

1.2

21.5

1.25

21.1

1.7

27.0

2085

1000

10x2x2.5

0.7

1.3

27.3

1.25

26.7

1.8

32.8

2789

500

12x2x2.5

0.7

1.4

28.4

1.25

27.6

1.8

33.7

3072

500

16x2x2.5

0.7

1.4

31.4

1.6

30.6

1.9

37.6

3815

500

20x2x2.5

0.7

1.5

35.5

1.6

34.9

2.0

42.1

4618

500

24x2x2.5

0.7

1.6

39.4

38.6

2.1

46.8

5699

500

30x2x2.5

0.7

1.7

41.9

40.9

2.2

49.3

6462

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

257

KCI

RE-Y(St)YKYRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
Metal Sheath
Lead Sheath (Cover)
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC

+70 oC

IEC 60332-1

Instrument Cables

Criteria

258

Conductor cross section

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

8.6

0.9

8.8

1.4

13.4

553

1000

2x3x0.5

0.6

1.0

12.1

0.9

12.1

1.5

16.9

810

1000

3x3x0.5

0.6

1.0

12.8

0.9

12.8

1.5

17.6

874

1000

4x3x0.5

0.6

1.0

13.8

0.9

13.8

1.5

18.6

959

1000

5x3x0.5

0.6

1.0

14.9

0.9

14.9

1.5

19.7

1053

1000

6x3x0.5

0.6

1.1

16.3

0.9

16.1

1.5

20.9

1198

1000

7x3x0.5

0.6

1.1

16.3

0.9

16.1

1.5

20.9

1225

1000

10x3x0.5

0.6

1.2

20.4

1.25

20.0

1.6

25.7

1768

1000

12x3x0.5

0.6

1.2

21.0

1.25

20.6

1.7

26.5

1883

1000

16x3x0.5

0.6

1.2

23.1

1.25

22.7

1.7

28.6

2142

1000

20x3x0.5

0.6

1.3

25.8

1.25

25.2

1.8

31.3

2507

500

24x3x0.5

0.6

1.3

28.4

1.25

27.8

1.8

33.9

2819

500

30x3x0.5

0.6

1.4

30.2

1.6

29.4

1.9

36.4

3417

500

1x3x0.75

0.6

0.9

9.1

0.9

9.3

1.4

13.9

588

1000

2x3x0.75

0.6

1.0

12.9

0.9

12.9

1.5

17.7

877

1000

3x3x0.75

0.6

1.0

13.6

0.9

13.6

1.5

18.4

958

1000

4x3x0.75

0.6

1.0

14.7

0.9

14.7

1.5

19.5

1058

1000

5x3x0.75

0.6

1.1

16.1

0.9

15.9

1.5

20.7

1215

1000

6x3x0.75

0.6

1.1

17.4

1.25

17.2

1.6

22.9

1481

1000

7x3x0.75

0.6

1.1

17.4

1.25

17.2

1.6

22.9

1517

1000

10x3x0.75

0.6

1.2

22.0

1.25

21.6

1.7

27.5

2000

1000

12x3x0.75

0.6

1.2

22.6

1.25

22.2

1.7

28.1

2116

1000

16x3x0.75

0.6

1.3

25.2

1.25

24.6

1.8

30.7

2521

500

20x3x0.75

0.6

1.3

27.9

1.25

27.3

1.8

33.4

2867

500

24x3x0.75

0.6

1.4

31.0

1.6

30.2

1.9

37.2

3574

500

30x3x0.75

0.6

1.5

33.0

1.6

32.4

2.0

39.6

4099

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

259

KCI

RE-Y(St)YKYRY
Diameter Under
Armour

mm

mm

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

9.5

0.9

9.7

1.4

14.3

619

1000

2x3x1

0.6

1.0

13.6

0.9

13.6

1.5

18.4

932

1000

3x3x1

0.6

1.0

14.3

0.9

14.3

1.5

19.1

1019

1000

4x3x1

0.6

1.0

15.5

0.9

15.5

1.5

20.3

1135

1000

5x3x1

0.6

1.1

17.0

0.9

16.8

1.6

21.8

1315

1000

6x3x1

0.6

1.1

18.4

1.25

18.2

1.6

23.9

1589

1000

7x3x1

0.6

1.1

18.4

1.25

18.2

1.6

23.9

1634

1000

10x3x1

0.6

1.2

23.3

1.25

22.9

1.7

28.8

2169

1000

12x3x1

0.6

1.2

24.0

1.25

23.6

1.7

29.5

2315

500

16x3x1

0.6

1.3

26.8

1.25

26.2

1.8

32.3

2767

500

20x3x1

0.6

1.4

29.9

1.25

29.1

1.8

35.2

3254

500

24x3x1

0.6

1.4

33.0

1.6

32.2

1.9

39.2

3923

500

30x3x1

0.6

1.5

35.1

1.6

34.5

2.0

41.7

4531

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

260

1x3x1.5

0.6

0.9

10.1

0.9

10.3

1.4

14.9

677

1000

2x3x1.5

0.6

1.0

14.7

0.9

14.7

1.5

19.5

1041

1000

3x3x1.5

0.6

1.1

15.7

0.9

15.5

1.5

20.3

1203

1000

4x3x1.5

0.6

1.1

17.1

0.9

16.9

1.6

21.9

1357

1000

5x3x1.5

0.6

1.1

18.6

1.25

18.4

1.6

24.1

1654

1000

6x3x1.5

0.6

1.2

20.3

1.25

19.9

1.7

25.8

1900

1000

7x3x1.5

0.6

1.2

20.3

1.25

19.9

1.7

25.8

1963

1000

10x3x1.5

0.6

1.3

25.7

1.25

25.1

1.8

31.2

2618

500

12x3x1.5

0.6

1.3

26.6

1.25

26.0

1.8

32.1

2808

500

16x3x1.5

0.6

1.4

29.6

1.25

28.8

1.9

35.1

3379

500

20x3x1.5

0.6

1.5

33.1

1.6

32.5

2.0

39.7

4292

500

24x3x1.5

0.6

1.6

37.2

1.6

36.4

2.1

43.8

5047

500

30x3x1.5

0.6

1.6

39.3

38.5

2.1

46.7

5962

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

11.7

0.9

11.7

1.4

16.3

829

1000

2x3x2.5

0.7

1.1

17.2

1.25

17.0

1.6

22.7

1457

1000

3x3x2.5

0.7

1.1

18.2

1.25

18.0

1.6

23.7

1633

1000

4x3x2.5

0.7

1.2

20.1

1.25

19.7

1.7

25.6

1911

1000

5x3x2.5

0.7

1.2

21.9

1.25

21.5

1.7

27.4

2149

1000

6x3x2.5

0.7

1.3

24.0

1.25

23.4

1.7

29.3

2456

500

7x3x2.5

0.7

1.3

24.0

1.25

23.4

1.7

29.3

2553

500

10x3x2.5

0.7

1.4

30.6

1.6

29.8

1.9

36.8

3688

500

12x3x2.5

0.7

1.4

31.6

1.6

30.8

1.9

37.8

3975

500

16x3x2.5

0.7

1.5

35.6

1.6

35.0

2.0

42.2

4903

500

20x3x2.5

0.7

1.6

39.8

39.0

2.2

47.4

6161

500

24x3x2.5

0.7

1.7

44.3

43.3

2.3

51.9

7140

500

30x3x2.5

0.7

1.8

47.1

46.3

2.3

54.9

8196

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

261

KCI

RE-Y(St)YKYRY , PiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+70 oC

Instrument Cables

262

IEC 60708 Full color

PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY , PiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

8.6

0.9

8.8

1.4

13.4

553

1000

2x2x0.5

0.6

1.0

12.4

0.9

12.4

1.5

17.2

825

1000

3x2x0.5

0.6

1.0

13.0

0.9

13.0

1.5

17.8

889

1000

4x2x0.5

0.6

1.0

14.1

0.9

14.1

1.5

18.9

975

1000

5x2x0.5

0.6

1.0

15.2

0.9

15.2

1.5

20.0

1070

1000

6x2x0.5

0.6

1.1

16.6

0.9

16.4

1.5

21.2

1217

1000

7x2x0.5

0.6

1.1

16.6

0.9

16.4

1.5

21.2

1243

1000

10x2x0.5

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1808

1000

12x2x0.5

0.6

1.2

21.6

1.25

21.2

1.7

27.1

1911

1000

16x2x0.5

0.6

1.2

23.7

1.25

23.3

1.7

29.2

2172

500

20x2x0.5

0.6

1.3

26.5

1.25

25.9

1.8

32.0

2549

500

24x2x0.5

0.6

1.4

29.4

1.25

28.6

1.8

34.7

2939

500

30x2x0.5

0.6

1.4

31.1

1.6

30.3

1.9

37.3

3476

500

1x2x0.75

0.6

0.9

9.1

0.9

9.3

1.4

13.9

584

1000

2x2x0.75

0.6

1.0

13.1

0.9

13.1

1.5

17.9

885

1000

3x2x0.75

0.6

1.0

13.9

0.9

13.9

1.5

18.7

959

1000

4x2x0.75

0.6

1.0

15.0

0.9

15.0

1.5

19.8

1061

1000

5x2x0.75

0.6

1.1

16.4

0.9

16.2

1.5

21.0

1217

1000

6x2x0.75

0.6

1.1

17.8

1.25

17.6

1.6

23.3

1476

1000

7x2x0.75

0.6

1.1

17.8

1.25

17.6

1.6

23.3

1508

1000

10x2x0.75

0.6

1.2

22.4

1.25

22.0

1.7

27.9

1998

1000

12x2x0.75

0.6

1.2

23.1

1.25

22.7

1.7

28.6

2117

1000

16x2x0.75

0.6

1.3

25.7

1.25

25.1

1.8

31.2

2503

500

20x2x0.75

0.6

1.4

28.7

1.25

27.9

1.8

34.0

2934

500

24x2x0.75

0.6

1.4

31.7

1.6

30.9

1.9

37.9

3545

500

30x2x0.75

0.6

1.5

33.7

1.6

33.1

2.0

40.3

4054

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

263

KCI

RE-Y(St)YKYRY , PiMF
Diameter Under
Armour

mm

mm

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

9.4

0.9

9.6

1.4

14.2

611

1000

2x2x1

0.6

1.0

13.8

0.9

13.8

1.5

18.6

928

1000

3x2x1

0.6

1.0

14.5

0.9

14.5

1.5

19.3

1015

1000

4x2x1

0.6

1.0

15.8

0.9

15.8

1.5

20.6

1126

1000

5x2x1

0.6

1.1

17.3

0.9

17.1

1.6

22.1

1302

1000

6x2x1

0.6

1.1

18.7

1.25

18.5

1.6

24.2

1576

1000

7x2x1

0.6

1.1

18.7

1.25

18.5

1.6

24.2

1615

1000

10x2x1

0.6

1.2

23.7

1.25

23.3

1.7

29.2

2137

500

12x2x1

0.6

1.2

24.4

1.25

24.0

1.7

29.9

2271

500

16x2x1

0.6

1.3

27.2

1.25

26.6

1.8

32.7

2702

500

20x2x1

0.6

1.4

30.4

1.6

29.6

1.9

36.6

3412

500

24x2x1

0.6

1.5

33.8

1.6

33.2

2.0

40.4

3987

500

30x2x1

0.6

1.5

35.7

1.6

35.1

2.0

42.3

4399

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

264

1x2x1.5

0.6

0.9

10.0

0.9

10.2

1.4

14.8

657

1000

2x2x1.5

0.6

1.0

14.8

0.9

14.8

1.5

19.6

1029

1000

3x2x1.5

0.6

1.1

15.9

0.9

15.7

1.5

20.5

1175

1000

4x2x1.5

0.6

1.1

17.3

0.9

17.1

1.6

22.1

1324

1000

5x2x1.5

0.6

1.1

18.7

1.25

18.5

1.6

24.2

1614

1000

6x2x1.5

0.6

1.2

20.5

1.25

20.1

1.7

26.0

1841

1000

7x2x1.5

0.6

1.2

20.5

1.25

20.1

1.7

26.0

1892

1000

10x2x1.5

0.6

1.3

26.0

1.25

25.4

1.8

31.5

2526

500

12x2x1.5

0.6

1.3

26.9

1.25

26.3

1.8

32.4

2693

500

16x2x1.5

0.6

1.4

29.9

1.25

29.1

1.9

35.4

3220

500

20x2x1.5

0.6

1.5

33.4

1.6

32.8

2.0

40.0

4080

500

24x2x1.5

0.6

1.6

37.6

1.6

36.8

2.1

44.2

4809

500

30x2x1.5

0.6

1.6

39.7

38.9

2.1

47.1

5639

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY , PiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.0

11.5

0.9

11.5

1.4

16.1

799

1000

2x2x2.5

0.7

1.1

17.3

1.25

17.1

1.6

22.8

1413

1000

3x2x2.5

0.7

1.1

18.3

1.25

18.1

1.6

23.8

1567

1000

4x2x2.5

0.7

1.2

20.1

1.25

19.7

1.7

25.6

1833

1000

5x2x2.5

0.7

1.2

21.9

1.25

21.5

1.7

27.4

2038

1000

6x2x2.5

0.7

1.3

24.0

1.25

23.4

1.7

29.3

2323

500

7x2x2.5

0.7

1.3

24.0

1.25

23.4

1.7

29.3

2399

500

10x2x2.5

0.7

1.4

30.6

1.6

29.8

1.9

36.8

3467

500

12x2x2.5

0.7

1.4

31.6

1.6

30.8

1.9

37.8

3708

500

16x2x2.5

0.7

1.5

35.7

1.6

35.1

2.0

42.3

4548

500

20x2x2.5

0.7

1.6

39.9

39.1

2.2

47.5

5717

500

24x2x2.5

0.7

1.8

44.6

43.8

2.3

52.4

6810

500

30x2x2.5

0.7

1.8

47.2

46.4

2.3

55.0

7530

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

265

KCI

RE-Y(St)YKYRY , TiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

Instrument Cables

+70 oC

Conductor cross section

PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x
km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

266
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY , TiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

9.0

0.9

9.2

1.4

13.8

581

1000

2x3x0.5

0.6

1.0

13.5

0.9

13.5

1.5

18.3

905

1000

3x3x0.5

0.6

1.0

14.2

0.9

14.2

1.5

19.0

987

1000

4x3x0.5

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1088

1000

5x3x0.5

0.6

1.1

16.9

0.9

16.7

1.6

21.7

1263

1000

6x3x0.5

0.6

1.1

18.3

1.25

18.1

1.6

23.8

1527

1000

7x3x0.5

0.6

1.1

18.3

1.25

18.1

1.6

23.8

1562

1000

10x3x0.5

0.6

1.2

23.1

1.25

22.7

1.7

28.6

2055

1000

12x3x0.5

0.6

1.2

23.8

1.25

23.4

1.7

29.3

2181

500

16x3x0.5

0.6

1.3

26.5

1.25

25.9

1.8

32.0

2592

500

20x3x0.5

0.6

1.4

29.6

1.25

28.8

1.8

34.9

3039

500

24x3x0.5

0.6

1.4

32.7

1.6

31.9

1.9

38.9

3677

500

30x3x0.5

0.6

1.5

34.8

1.6

34.2

2.0

41.4

4208

500

1x3x0.75

0.6

0.9

9.4

0.9

9.6

1.4

14.2

622

1000

2x3x0.75

0.6

1.0

14.3

0.9

14.3

1.5

19.1

982

1000

3x3x0.75

0.6

1.0

15.1

0.9

15.1

1.5

19.9

1077

1000

4x3x0.75

0.6

1.1

16.6

0.9

16.4

1.6

21.4

1257

1000

5x3x0.75

0.6

1.1

18.1

1.25

17.9

1.6

23.6

1528

1000

6x3x0.75

0.6

1.1

19.6

1.25

19.4

1.6

25.1

1682

1000

7x3x0.75

0.6

1.1

19.6

1.25

19.4

1.6

25.1

1727

1000

10x3x0.75

0.6

1.3

25.0

1.25

24.4

1.8

30.5

2374

500

12x3x0.75

0.6

1.3

25.8

1.25

25.2

1.8

31.3

2526

500

16x3x0.75

0.6

1.4

28.7

1.25

27.9

1.8

34.0

3001

500

20x3x0.75

0.6

1.4

31.9

1.6

31.1

1.9

38.1

3672

500

24x3x0.75

0.6

1.5

35.8

1.6

35.2

2.0

42.4

4377

500

30x3x0.75

0.6

1.6

38.1

1.6

37.3

2.1

44.7

4965

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

267

KCI

RE-Y(St)YKYRY , TiMF
Diameter Under
Armour

mm

mm

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

9.8

0.9

10.0

1.4

14.6

647

1000

2x3x1

0.6

1.0

15.1

0.9

15.1

1.5

19.9

1034

1000

3x3x1

0.6

1.1

16.1

0.9

15.9

1.5

20.7

1188

1000

4x3x1

0.6

1.1

17.5

0.9

17.3

1.6

22.3

1339

1000

5x3x1

0.6

1.1

19.0

1.25

18.8

1.6

24.5

1628

1000

6x3x1

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1867

1000

7x3x1

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1921

1000

10x3x1

0.6

1.3

26.4

1.25

25.8

1.8

31.9

2563

500

12x3x1

0.6

1.3

27.3

1.25

26.7

1.8

32.8

2736

500

16x3x1

0.6

1.4

30.4

1.6

29.6

1.9

36.6

3504

500

20x3x1

0.6

1.5

34.0

1.6

33.4

2.0

40.6

4168

500

24x3x1

0.6

1.6

38.2

1.6

37.4

2.1

44.8

4892

500

30x3x1

0.6

1.6

40.4

39.6

2.1

47.8

5749

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

268

1x3x1.5

0.6

0.9

10.5

0.9

10.7

1.4

15.3

707

1000

2x3x1.5

0.6

1.1

16.5

0.9

16.3

1.6

21.3

1212

1000

3x3x1.5

0.6

1.1

17.4

1.25

17.2

1.6

22.9

1486

1000

4x3x1.5

0.6

1.1

19.0

1.25

18.8

1.6

24.5

1660

1000

5x3x1.5

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1923

1000

6x3x1.5

0.6

1.2

22.7

1.25

22.3

1.7

28.2

2135

1000

7x3x1.5

0.6

1.2

22.7

1.25

22.3

1.7

28.2

2207

1000

10x3x1.5

0.6

1.4

29.1

1.25

28.3

1.8

34.4

3046

500

12x3x1.5

0.6

1.4

30.0

1.25

29.2

1.9

35.5

3278

500

16x3x1.5

0.6

1.5

33.5

1.6

32.9

2.0

40.1

4235

500

20x3x1.5

0.6

1.6

37.9

1.6

37.1

2.1

44.5

5048

500

24x3x1.5

0.6

1.7

42.1

41.1

2.2

49.5

6226

500

30x3x1.5

0.6

1.7

44.5

43.5

2.2

51.9

6903

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-Y(St)YKYRY , TiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

Diameter Under
Armour

mm

Standard
Packing Length

Armour Wire
Diameter

mm

Weight

Diameter Over
Lead Sheath

mm

Overall
Diameter

Lead Sheath
Thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

12.0

0.9

12.0

1.5

16.8

868

1000

2x3x2.5

0.7

1.1

19.0

1.25

18.8

1.6

24.5

1602

1000

3x3x2.5

0.7

1.2

20.4

1.25

20.0

1.7

25.9

1868

1000

4x3x2.5

0.7

1.2

22.2

1.25

21.8

1.7

27.7

2121

1000

5x3x2.5

0.7

1.3

24.5

1.25

23.9

1.8

30.0

2459

500

6x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2734

500

7x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2842

500

10x3x2.5

0.7

1.5

34.3

1.6

33.7

2.0

40.9

4265

500

12x3x2.5

0.7

1.5

35.9

1.6

35.3

2.0

42.5

4654

500

16x3x2.5

0.7

1.6

40.0

39.2

2.2

47.6

5948

500

20x3x2.5

0.7

1.8

45.0

44.2

2.3

52.8

7196

500

24x3x2.5

0.7

1.9

50.4

2.5

49.4

2.4

59.2

8943

500

30x3x2.5

0.7

2.0

53.6

2.5

52.4

2.5

62.4

10168

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

269

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-Y(St)YKYRY

Fire Resistant

EN 50288-7 (500 V)

RE-Y(St)YKYRY Multi-Core
RE-Y(St)YKYRY Multi-Pair
RE-Y(St)YKYRY Multi-Triple
RE-Y(St)YKYRY PiMF
RE-Y(St)YKYRY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH

Fire Resistant

Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF

KCI

RE-2X(St)YKYRY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Mica-glass Tape + XLPE


Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Yellow or White (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

272
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


2x0.5

0.6

0.9

9.2

0.9

9.4

1.4

14.0

564

1000

3x0.5

0.6

0.9

9.7

0.9

9.9

1.4

14.5

594

1000

4x0.5

0.6

0.9

10.3

0.9

10.5

1.4

15.1

638

1000

5x0.5

0.6

0.9

11.1

0.9

11.3

1.4

15.9

689

1000

6x0.5

0.6

0.9

11.8

0.9

12.0

1.4

16.6

736

1000

7x0.5

0.6

0.9

11.8

0.9

12.0

1.4

16.6

746

1000

8x0.5

0.6

1.0

13.6

0.9

13.6

1.5

18.4

883

1000

10x0.5

0.6

1.0

14.6

0.9

14.6

1.5

19.4

962

1000

12x0.5

0.6

1.0

15.0

0.9

15.0

1.5

19.8

1003

1000

16x0.5

0.6

1.0

16.4

0.9

16.4

1.5

21.2

1120

1000

20x0.5

0.6

1.1

18.2

0.9

18.0

1.6

23.0

1306

1000

24x0.5

0.6

1.1

20.0

1.25

19.8

1.6

25.5

1602

1000

30x0.5

0.6

1.1

21.0

1.25

20.8

1.6

26.5

1723

1000

2x0.75

0.6

0.9

9.7

0.9

9.9

1.4

14.5

594

1000

3x0.75

0.6

0.9

10.1

0.9

10.3

1.4

14.9

634

1000

4x0.75

0.6

0.9

10.8

0.9

11.0

1.4

15.6

683

1000

5x0.75

0.6

0.9

11.6

0.9

11.8

1.4

16.4

740

1000

6x0.75

0.6

1.0

12.7

0.9

12.7

1.5

17.5

837

1000

7x0.75

0.6

1.0

12.7

0.9

12.7

1.5

17.5

849

1000

8x0.75

0.6

1.0

14.3

0.9

14.3

1.5

19.1

959

1000

10x0.75

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1049

1000

12x0.75

0.6

1.0

15.9

0.9

15.9

1.5

20.7

1096

1000

16x0.75

0.6

1.1

17.6

0.9

17.4

1.6

22.4

1290

1000

20x0.75

0.6

1.1

19.4

1.25

19.2

1.6

24.9

1590

1000

24x0.75

0.6

1.1

21.2

1.25

21.0

1.6

26.7

1770

1000

30x0.75

0.6

1.2

22.6

1.25

22.2

1.7

28.1

1986

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

273

KCI

RE-2X(St)YKYRY

mm

mm

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


2x1

0.6

0.9

10.0

0.9

10.2

1.4

14.8

616

1000

3x1

0.6

0.9

10.5

0.9

10.7

1.4

15.3

659

1000

4x1

0.6

0.9

11.3

0.9

11.5

1.4

16.1

717

1000

5x1

0.6

1.0

12.3

0.9

12.3

1.4

16.9

809

1000

6x1

0.6

1.0

13.2

0.9

13.2

1.5

18.0

881

1000

7x1

0.6

1.0

13.2

0.9

13.2

1.5

18.0

897

1000

8x1

0.6

1.0

15.0

0.9

15.0

1.5

19.8

1013

1000

10x1

0.6

1.0

16.2

0.9

16.2

1.5

21.0

1111

1000

12x1

0.6

1.0

16.6

0.9

16.6

1.5

21.4

1170

1000

16x1

0.6

1.1

18.4

0.9

18.2

1.6

23.2

1380

1000

20x1

0.6

1.1

20.3

1.25

20.1

1.6

25.8

1700

1000

24x1

0.6

1.2

22.5

1.25

22.1

1.7

28.0

1968

1000

30x1

0.6

1.2

23.7

1.25

23.3

1.7

29.2

2144

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

274

2x1.5

0.6

0.9

10.6

0.9

10.8

1.4

15.4

666

1000

3x1.5

0.6

0.9

11.2

0.9

11.4

1.4

16.0

717

1000

4x1.5

0.6

1.0

12.2

0.9

12.2

1.4

16.8

821

1000

5x1.5

0.6

1.0

13.1

0.9

13.1

1.5

17.9

901

1000

6x1.5

0.6

1.0

14.1

0.9

14.1

1.5

18.9

977

1000

7x1.5

0.6

1.0

14.1

0.9

14.1

1.5

18.9

998

1000

8x1.5

0.6

1.0

16.1

0.9

16.1

1.5

20.9

1134

1000

10x1.5

0.6

1.1

17.6

0.9

17.4

1.6

22.4

1309

1000

12x1.5

0.6

1.1

18.1

0.9

17.9

1.6

22.9

1383

1000

16x1.5

0.6

1.1

19.9

1.25

19.7

1.6

25.4

1719

1000

20x1.5

0.6

1.2

22.1

1.25

21.7

1.7

27.6

2015

1000

24x1.5

0.6

1.2

24.3

1.25

23.9

1.7

29.8

2250

500

30x1.5

0.6

1.3

25.8

1.25

25.2

1.7

31.1

2550

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


2x2.5

0.7

1.0

12.1

0.9

12.1

1.4

16.7

805

1000

3x2.5

0.7

1.0

12.7

0.9

12.7

1.5

17.5

880

1000

4x2.5

0.7

1.0

13.7

0.9

13.7

1.5

18.5

969

1000

5x2.5

0.7

1.0

14.8

0.9

14.8

1.5

19.6

1062

1000

6x2.5

0.7

1.1

16.2

0.9

16.0

1.5

20.8

1210

1000

7x2.5

0.7

1.1

16.2

0.9

16.0

1.5

20.8

1242

1000

8x2.5

0.7

1.1

18.5

1.25

18.3

1.6

24.0

1568

1000

10x2.5

0.7

1.1

20.0

1.25

19.8

1.6

25.5

1741

1000

12x2.5

0.7

1.2

20.9

1.25

20.5

1.7

26.4

1913

1000

16x2.5

0.7

1.2

23.0

1.25

22.6

1.7

28.5

2190

1000

20x2.5

0.7

1.3

25.6

1.25

25.0

1.8

31.1

2580

500

24x2.5

0.7

1.3

28.2

1.25

27.6

1.8

33.7

2899

500

30x2.5

0.7

1.4

30.0

1.25

29.2

1.8

35.3

3296

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

275

KCI

RE-2X(St)YKYRY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

IEC 60708 Full color

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

276
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

9.2

0.9

9.4

1.4

14.0

565

1000

2x2x0.5

0.6

1.0

12.8

0.9

12.8

1.4

17.4

796

1000

3x2x0.5

0.6

1.0

13.4

0.9

13.4

1.5

18.2

859

1000

4x2x0.5

0.6

1.0

14.5

0.9

14.5

1.5

19.3

942

1000

5x2x0.5

0.6

1.0

15.7

0.9

15.7

1.5

20.5

1023

1000

6x2x0.5

0.6

1.1

17.2

0.9

17.0

1.5

21.8

1165

1000

7x2x0.5

0.6

1.1

17.2

0.9

17.0

1.5

21.8

1184

1000

10x2x0.5

0.6

1.1

21.4

1.25

21.2

1.6

26.9

1659

1000

12x2x0.5

0.6

1.2

22.3

1.25

21.9

1.7

27.8

1817

1000

16x2x0.5

0.6

1.2

24.6

1.25

24.2

1.7

30.1

2046

500

20x2x0.5

0.6

1.3

27.4

1.25

26.8

1.8

32.9

2388

500

24x2x0.5

0.6

1.3

30.3

1.6

29.7

1.8

36.5

2899

500

30x2x0.5

0.6

1.4

32.2

1.6

31.4

1.9

38.4

3246

500

1x2x0.75

0.6

0.9

9.7

0.9

9.9

1.4

14.5

595

1000

2x2x0.75

0.6

1.0

13.4

0.9

13.4

1.5

18.2

860

1000

3x2x0.75

0.6

1.0

14.2

0.9

14.2

1.5

19.0

924

1000

4x2x0.75

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1017

1000

5x2x0.75

0.6

1.1

16.8

0.9

16.6

1.5

21.4

1162

1000

6x2x0.75

0.6

1.1

18.2

0.9

18.0

1.6

23.0

1280

1000

7x2x0.75

0.6

1.1

18.2

0.9

18.0

1.6

23.0

1305

1000

10x2x0.75

0.6

1.2

23.0

1.25

22.6

1.7

28.5

1897

1000

12x2x0.75

0.6

1.2

23.7

1.25

23.3

1.7

29.2

2000

500

16x2x0.75

0.6

1.3

26.4

1.25

25.8

1.7

31.7

2346

500

20x2x0.75

0.6

1.3

29.3

1.25

28.7

1.8

34.8

2669

500

24x2x0.75

0.6

1.4

32.5

1.6

31.7

1.9

38.7

3321

500

30x2x0.75

0.6

1.4

34.4

1.6

33.6

1.9

40.6

3634

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

277

KCI

RE-2X(St)YKYRY

mm

mm

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

10.0

0.9

10.2

1.4

14.8

616

1000

2x2x1

0.6

1.0

14.0

0.9

14.0

1.5

18.8

900

1000

3x2x1

0.6

1.0

14.8

0.9

14.8

1.5

19.6

972

1000

4x2x1

0.6

1.0

16.1

0.9

16.1

1.5

20.9

1079

1000

5x2x1

0.6

1.1

17.6

0.9

17.4

1.5

22.2

1233

1000

6x2x1

0.6

1.1

19.1

1.25

18.9

1.6

24.6

1511

1000

7x2x1

0.6

1.1

19.1

1.25

18.9

1.6

24.6

1542

1000

10x2x1

0.6

1.2

24.2

1.25

23.8

1.7

29.7

2028

500

12x2x1

0.6

1.2

25.0

1.25

24.6

1.7

30.5

2145

500

16x2x1

0.6

1.3

27.8

1.25

27.2

1.8

33.3

2536

500

20x2x1

0.6

1.3

30.8

1.6

30.2

1.8

37.0

3113

500

24x2x1

0.6

1.4

34.3

1.6

33.5

1.9

40.5

3599

500

30x2x1

0.6

1.5

36.5

1.6

35.9

2.0

43.1

4103

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

278

1x2x1.5

0.6

0.9

10.6

0.9

10.8

1.4

15.4

667

1000

2x2x1.5

0.6

1.0

15.0

0.9

15.0

1.5

19.8

989

1000

3x2x1.5

0.6

1.0

15.9

0.9

15.9

1.5

20.7

1082

1000

4x2x1.5

0.6

1.1

17.5

0.9

17.3

1.6

22.3

1266

1000

5x2x1.5

0.6

1.1

19.0

1.25

18.8

1.6

24.5

1539

1000

6x2x1.5

0.6

1.1

20.6

1.25

20.4

1.6

26.1

1692

1000

7x2x1.5

0.6

1.1

20.6

1.25

20.4

1.6

26.1

1734

1000

10x2x1.5

0.6

1.3

26.3

1.25

25.7

1.8

31.8

2396

500

12x2x1.5

0.6

1.3

27.2

1.25

26.6

1.8

32.7

2543

500

16x2x1.5

0.6

1.3

30.1

1.6

29.5

1.9

36.5

3153

500

20x2x1.5

0.6

1.4

33.7

1.6

32.9

1.9

39.9

3699

500

24x2x1.5

0.6

1.5

37.5

1.6

36.9

2.0

44.1

4330

500

30x2x1.5

0.6

1.6

40.3

39.5

2.1

47.7

5302

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.0

12.1

0.9

12.1

1.4

16.7

806

1000

2x2x2.5

0.7

1.1

17.2

0.9

17.0

1.6

22.0

1227

1000

3x2x2.5

0.7

1.1

18.3

1.25

18.1

1.6

23.8

1499

1000

4x2x2.5

0.7

1.1

19.9

1.25

19.7

1.6

25.4

1678

1000

5x2x2.5

0.7

1.2

21.9

1.25

21.5

1.7

27.4

1936

1000

6x2x2.5

0.7

1.2

23.8

1.25

23.4

1.7

29.3

2132

500

7x2x2.5

0.7

1.2

23.8

1.25

23.4

1.7

29.3

2197

500

10x2x2.5

0.7

1.4

30.6

1.6

29.8

1.9

36.8

3277

500

12x2x2.5

0.7

1.4

31.6

1.6

30.8

1.9

37.8

3494

500

16x2x2.5

0.7

1.5

35.3

1.6

34.7

2.0

41.9

4205

500

20x2x2.5

0.7

1.6

39.9

39.1

2.1

47.3

5358

500

24x2x2.5

0.7

1.7

44.4

43.4

2.2

51.8

6180

500

30x2x2.5

0.7

1.8

47.2

46.4

2.3

55.0

7040

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

279

KCI

RE-2X(St)YKYRY
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
Metal Sheath
Lead Sheath (Cover)
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

IEC 60331

Instrument Cables

Criteria
Conductor cross section

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

280
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

9.7

0.9

9.9

1.4

14.5

594

1000

2x3x0.5

0.6

1.0

13.9

0.9

13.9

1.5

18.7

889

1000

3x3x0.5

0.6

1.0

14.7

0.9

14.7

1.5

19.5

958

1000

4x3x0.5

0.6

1.0

16.0

0.9

16.0

1.5

20.8

1057

1000

5x3x0.5

0.6

1.1

17.5

0.9

17.3

1.5

22.1

1213

1000

6x3x0.5

0.6

1.1

18.9

1.25

18.7

1.6

24.4

1476

1000

7x3x0.5

0.6

1.1

18.9

1.25

18.7

1.6

24.4

1505

1000

10x3x0.5

0.6

1.2

24.0

1.25

23.6

1.7

29.5

1990

500

12x3x0.5

0.6

1.2

24.7

1.25

24.3

1.7

30.2

2092

500

16x3x0.5

0.6

1.3

27.5

1.25

26.9

1.8

33.0

2480

500

20x3x0.5

0.6

1.3

30.6

1.6

30.0

1.8

36.8

3029

500

24x3x0.5

0.6

1.4

34.0

1.6

33.2

1.9

40.2

3502

500

30x3x0.5

0.6

1.5

36.2

1.6

35.6

2.0

42.8

4005

500

1x3x0.75

0.6

0.9

10.1

0.9

10.3

1.4

14.9

634

1000

2x3x0.75

0.6

1.0

14.7

0.9

14.7

1.5

19.5

956

1000

3x3x0.75

0.6

1.0

15.5

0.9

15.5

1.5

20.3

1043

1000

4x3x0.75

0.6

1.1

17.1

0.9

16.9

1.5

21.7

1203

1000

5x3x0.75

0.6

1.1

18.6

0.9

18.4

1.6

23.4

1338

1000

6x3x0.75

0.6

1.1

20.1

1.25

19.9

1.6

25.6

1623

1000

7x3x0.75

0.6

1.1

20.1

1.25

19.9

1.6

25.6

1661

1000

10x3x0.75

0.6

1.2

25.5

1.25

25.1

1.7

31.0

2199

500

12x3x0.75

0.6

1.3

26.6

1.25

26.0

1.7

31.9

2405

500

16x3x0.75

0.6

1.3

29.4

1.25

28.8

1.8

34.9

2776

500

20x3x0.75

0.6

1.4

32.9

1.6

32.1

1.9

39.1

3505

500

24x3x0.75

0.6

1.5

36.6

1.6

36.0

2.0

43.2

4103

500

30x3x0.75

0.6

1.5

39.1

38.5

2.1

46.7

4935

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

281

KCI

RE-2X(St)YKYRY

mm

mm

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

10.5

0.9

10.7

1.4

15.3

660

1000

2x3x1

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1005

1000

3x3x1

0.6

1.0

16.3

0.9

16.3

1.5

21.1

1102

1000

4x3x1

0.6

1.1

17.9

0.9

17.7

1.6

22.7

1290

1000

5x3x1

0.6

1.1

19.5

1.25

19.3

1.6

25.0

1573

1000

6x3x1

0.6

1.1

21.1

1.25

20.9

1.6

26.6

1730

1000

7x3x1

0.6

1.1

21.1

1.25

20.9

1.6

26.6

1777

1000

10x3x1

0.6

1.3

27.1

1.25

26.5

1.8

32.6

2451

500

12x3x1

0.6

1.3

28.0

1.25

27.4

1.8

33.5

2617

500

16x3x1

0.6

1.3

31.0

1.6

30.4

1.9

37.4

3257

500

20x3x1

0.6

1.4

34.7

1.6

33.9

1.9

40.9

3804

500

24x3x1

0.6

1.5

38.6

38.0

2.0

46.0

4795

500

30x3x1

0.6

1.6

41.5

40.7

2.1

48.9

5485

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

282

1x3x1.5

0.6

0.9

11.2

0.9

11.4

1.4

16.0

718

1000

2x3x1.5

0.6

1.1

16.7

0.9

16.5

1.5

21.3

1166

1000

3x3x1.5

0.6

1.1

17.7

0.9

17.5

1.6

22.5

1296

1000

4x3x1.5

0.6

1.1

19.3

1.25

19.1

1.6

24.8

1605

1000

5x3x1.5

0.6

1.2

21.2

1.25

20.8

1.6

26.5

1843

1000

6x3x1.5

0.6

1.2

23.0

1.25

22.6

1.7

28.5

2042

1000

7x3x1.5

0.6

1.2

23.0

1.25

22.6

1.7

28.5

2106

1000

10x3x1.5

0.6

1.3

29.3

1.25

28.7

1.8

34.8

2826

500

12x3x1.5

0.6

1.4

30.5

1.6

29.7

1.9

36.7

3350

500

16x3x1.5

0.6

1.4

33.8

1.6

33.0

1.9

40.0

3877

500

20x3x1.5

0.6

1.5

38.3

37.7

2.1

45.9

5010

500

24x3x1.5

0.6

1.6

42.5

41.7

2.1

49.9

5797

500

30x3x1.5

0.6

1.7

45.3

44.3

2.2

52.7

6552

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

12.7

0.9

12.7

1.5

17.5

882

1000

2x3x2.5

0.7

1.1

19.0

1.25

18.8

1.6

24.5

1542

1000

3x3x2.5

0.7

1.1

20.2

1.25

20.0

1.6

25.7

1721

1000

4x3x2.5

0.7

1.2

22.3

1.25

21.9

1.7

27.8

2028

1000

5x3x2.5

0.7

1.2

24.3

1.25

23.9

1.7

29.8

2262

500

6x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2613

500

7x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2709

500

10x3x2.5

0.7

1.5

34.4

1.6

33.8

2.0

41.0

4055

500

12x3x2.5

0.7

1.5

35.5

1.6

34.9

2.0

42.1

4348

500

16x3x2.5

0.7

1.6

40.0

39.2

2.1

47.4

5625

500

20x3x2.5

0.7

1.7

44.8

43.8

2.2

52.2

6623

500

24x3x2.5

0.7

1.8

49.9

2.5

49.1

2.4

58.9

8278

500

30x3x2.5

0.7

1.9

53.5

2.5

52.5

2.4

62.3

9446

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

283

KCI

Kerman & Kavian Cable Industries ( KCI )

RE-2X(St)YKYRY , PiMF

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

IEC 60708 Full color

Mica-glass Tape + XLPE


Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria
Conductor cross section

Black,Blue (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

284
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

Armour Wire
Diameter

Diameter Under
Armour

mm

mm

mm

Standard
Packing Length

Diameter Over
Lead Sheath

mm

Weight

Lead Sheath
Thickness

mm

Overall
Diameter

Insulation
thickness

mm2

Sheath thickness

Nominal cross
section area of
conductor

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

KCI

RE-2X(St)YKYRY , PiMF

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

9.6

0.9

9.8

1.4

14.4

593

1000

2x2x0.5

0.6

1.0

14.1

0.9

14.1

1.5

18.9

898

1000

3x2x0.5

0.6

1.0

14.9

0.9

14.9

1.5

19.7

972

1000

4x2x0.5

0.6

1.0

16.2

0.9

16.2

1.5

21.0

1071

1000

5x2x0.5

0.6

1.1

17.7

0.9

17.5

1.5

22.3

1223

1000

6x2x0.5

0.6

1.1

19.2

1.25

19.0

1.6

24.7

1498

1000

7x2x0.5

0.6

1.1

19.2

1.25

19.0

1.6

24.7

1526

1000

10x2x0.5

0.6

1.2

24.3

1.25

23.9

1.7

29.8

2005

500

12x2x0.5

0.6

1.2

25.1

1.25

24.7

1.7

30.6

2116

500

16x2x0.5

0.6

1.3

28.0

1.25

27.4

1.8

33.5

2506

500

20x2x0.5

0.6

1.4

31.2

1.6

30.4

1.9

37.4

3161

500

24x2x0.5

0.6

1.4

34.5

1.6

33.7

1.9

40.7

3539

500

30x2x0.5

0.6

1.5

36.7

1.6

36.1

2.0

43.3

4043

500

1x2x0.75

0.6

0.9

10.0

0.9

10.2

1.4

14.8

624

1000

2x2x0.75

0.6

1.0

14.8

0.9

14.8

1.5

19.6

963

1000

3x2x0.75

0.6

1.0

15.7

0.9

15.7

1.5

20.5

1041

1000

4x2x0.75

0.6

1.1

17.3

0.9

17.1

1.5

21.9

1205

1000

5x2x0.75

0.6

1.1

18.7

1.25

18.5

1.6

24.2

1483

1000

6x2x0.75

0.6

1.1

20.3

1.25

20.1

1.6

25.8

1615

1000

7x2x0.75

0.6

1.1

20.3

1.25

20.1

1.6

25.8

1650

1000

10x2x0.75

0.6

1.3

26.0

1.25

25.4

1.7

31.3

2265

500

12x2x0.75

0.6

1.3

26.9

1.25

26.3

1.8

32.4

2407

500

16x2x0.75

0.6

1.3

29.7

1.25

29.1

1.8

35.2

2754

500

20x2x0.75

0.6

1.4

33.2

1.6

32.4

1.9

39.4

3481

500

24x2x0.75

0.6

1.5

37.0

1.6

36.4

2.0

43.6

4071

500

30x2x0.75

0.6

1.5

39.5

38.9

2.1

47.1

4869

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

285

KCI

RE-2X(St)YKYRY , PiMF

mm

mm

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

10.4

0.9

10.6

1.4

15.2

651

1000

2x2x1

0.6

1.0

15.5

0.9

15.5

1.5

20.3

1005

1000

3x2x1

0.6

1.0

16.4

0.9

16.4

1.5

21.2

1097

1000

4x2x1

0.6

1.1

18.0

0.9

17.8

1.6

22.8

1275

1000

5x2x1

0.6

1.1

19.6

1.25

19.4

1.6

25.1

1563

1000

6x2x1

0.6

1.1

21.3

1.25

21.1

1.6

26.8

1715

1000

7x2x1

0.6

1.1

21.3

1.25

21.1

1.6

26.8

1755

1000

10x2x1

0.6

1.3

27.3

1.25

26.7

1.8

32.8

2418

500

12x2x1

0.6

1.3

28.2

1.25

27.6

1.8

33.7

2562

500

16x2x1

0.6

1.4

31.4

1.6

30.6

1.9

37.6

3265

500

20x2x1

0.6

1.4

34.9

1.6

34.1

1.9

41.1

3723

500

24x2x1

0.6

1.5

39.3

38.7

2.1

46.9

4774

500

30x2x1

0.6

1.6

41.8

41.0

2.1

49.2

5335

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

286

1x2x1.5

0.6

0.9

11.0

0.9

11.2

1.4

15.8

702

1000

2x2x1.5

0.6

1.1

16.8

0.9

16.6

1.5

21.4

1148

1000

3x2x1.5

0.6

1.1

17.7

0.9

17.5

1.6

22.5

1267

1000

4x2x1.5

0.6

1.1

19.3

1.25

19.1

1.6

24.8

1565

1000

5x2x1.5

0.6

1.2

21.3

1.25

20.9

1.6

26.6

1793

1000

6x2x1.5

0.6

1.2

23.1

1.25

22.7

1.7

28.6

1981

1000

7x2x1.5

0.6

1.2

23.1

1.25

22.7

1.7

28.6

2034

1000

10x2x1.5

0.6

1.3

29.4

1.25

28.8

1.8

34.9

2723

500

12x2x1.5

0.6

1.4

30.6

1.6

29.8

1.9

36.8

3225

500

16x2x1.5

0.6

1.4

33.9

1.6

33.1

1.9

40.1

3708

500

20x2x1.5

0.6

1.5

38.4

37.8

2.1

46.0

4824

500

24x2x1.5

0.6

1.6

42.7

41.9

2.1

50.1

5543

500

30x2x1.5

0.6

1.7

45.4

44.4

2.2

52.8

6232

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY , PiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

1.0

12.4

0.9

12.4

1.5

17.2

845

1000

2x2x2.5

0.7

1.1

19.0

1.25

18.8

1.6

24.5

1499

1000

3x2x2.5

0.7

1.1

20.1

1.25

19.9

1.6

25.6

1656

1000

4x2x2.5

0.7

1.2

22.2

1.25

21.8

1.7

27.7

1931

1000

5x2x2.5

0.7

1.2

24.2

1.25

23.8

1.7

29.7

2154

500

6x2x2.5

0.7

1.3

26.6

1.25

26.0

1.8

32.1

2472

500

7x2x2.5

0.7

1.3

26.6

1.25

26.0

1.8

32.1

2548

500

10x2x2.5

0.7

1.5

34.2

1.6

33.6

2.0

40.8

3838

500

12x2x2.5

0.7

1.5

35.4

1.6

34.8

2.0

42.0

4089

500

16x2x2.5

0.7

1.6

39.9

39.1

2.1

47.3

5280

500

20x2x2.5

0.7

1.7

44.7

43.7

2.2

52.1

6165

500

24x2x2.5

0.7

1.8

49.7

2.5

48.9

2.4

58.7

7761

500

30x2x2.5

0.7

1.9

53.3

2.5

52.3

2.4

62.1

8799

500

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

287

KCI

RE-2X(St)YKYRY , TiMF
EN 50288-7 (500 V)

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Conductor cross section

Mica-glass Tape + XLPE


Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC

IEC 60331

Criteria

Blue,White,Red (Numbered)

10x O.D

Screened

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

288
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY , TiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

10.0

0.9

10.2

1.4

14.8

623

1000

2x3x0.5

0.6

1.0

15.4

0.9

15.4

1.5

20.2

995

1000

3x3x0.5

0.6

1.0

16.3

0.9

16.3

1.5

21.1

1078

1000

4x3x0.5

0.6

1.1

18.0

0.9

17.8

1.6

22.8

1258

1000

5x3x0.5

0.6

1.1

19.5

1.25

19.3

1.6

25.0

1543

1000

6x3x0.5

0.6

1.1

21.2

1.25

21.0

1.6

26.7

1691

1000

7x3x0.5

0.6

1.1

21.2

1.25

21.0

1.6

26.7

1729

1000

10x3x0.5

0.6

1.3

27.2

1.25

26.6

1.8

32.7

2379

500

12x3x0.5

0.6

1.3

28.1

1.25

27.5

1.8

33.6

2518

500

16x3x0.5

0.6

1.4

31.3

1.6

30.5

1.9

37.5

3208

500

20x3x0.5

0.6

1.4

34.8

1.6

34.0

1.9

41.0

3653

500

24x3x0.5

0.6

1.5

39.1

38.5

2.0

46.5

4672

500

30x3x0.5

0.6

1.6

41.6

40.8

2.1

49.0

5233

500

1x3x0.75

0.6

0.9

10.5

0.9

10.7

1.4

15.3

664

1000

2x3x0.75

0.6

1.0

16.3

0.9

16.3

1.5

21.1

1066

1000

3x3x0.75

0.6

1.1

17.4

0.9

17.2

1.5

22.0

1217

1000

4x3x0.75

0.6

1.1

19.0

1.25

18.8

1.6

24.5

1511

1000

5x3x0.75

0.6

1.1

20.7

1.25

20.5

1.6

26.2

1670

1000

6x3x0.75

0.6

1.2

22.7

1.25

22.3

1.7

28.2

1919

1000

7x3x0.75

0.6

1.2

22.7

1.25

22.3

1.7

28.2

1967

1000

10x3x0.75

0.6

1.3

28.9

1.25

28.3

1.8

34.4

2616

500

12x3x0.75

0.6

1.3

29.8

1.25

29.2

1.8

35.3

2778

500

16x3x0.75

0.6

1.4

33.3

1.6

32.5

1.9

39.5

3552

500

20x3x0.75

0.6

1.5

37.3

1.6

36.7

2.0

43.9

4224

500

24x3x0.75

0.6

1.6

41.9

41.1

2.1

49.3

5311

500

30x3x0.75

0.6

1.7

44.5

43.5

2.2

51.9

5958

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

289

KCI

RE-2X(St)YKYRY , TiMF

mm

mm

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

Fire Resistant

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

10.9

0.9

11.1

1.4

15.7

689

1000

2x3x1

0.6

1.1

17.2

0.9

17.0

1.5

21.8

1171

1000

3x3x1

0.6

1.1

18.2

0.9

18.0

1.6

23.0

1295

1000

4x3x1

0.6

1.1

19.9

1.25

19.7

1.6

25.4

1597

1000

5x3x1

0.6

1.2

21.9

1.25

21.5

1.7

27.4

1850

1000

6x3x1

0.6

1.2

23.8

1.25

23.4

1.7

29.3

2033

500

7x3x1

0.6

1.2

23.8

1.25

23.4

1.7

29.3

2090

500

10x3x1

0.6

1.3

30.3

1.6

29.7

1.8

36.5

3022

500

12x3x1

0.6

1.4

31.6

1.6

30.8

1.9

37.8

3317

500

16x3x1

0.6

1.4

35.0

1.6

34.2

1.9

41.2

3817

500

20x3x1

0.6

1.5

39.6

39.0

2.1

47.2

4946

500

24x3x1

0.6

1.6

44.1

43.3

2.2

51.7

5728

500

30x3x1

0.6

1.7

46.9

45.9

2.2

54.3

6449

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

290

1x3x1.5

0.6

0.9

11.5

0.9

11.7

1.4

16.3

748

1000

2x3x1.5

0.6

1.1

18.4

1.25

18.2

1.6

23.9

1444

1000

3x3x1.5

0.6

1.1

19.5

1.25

19.3

1.6

25.0

1597

1000

4x3x1.5

0.6

1.2

21.6

1.25

21.2

1.7

27.1

1862

1000

5x3x1.5

0.6

1.2

23.5

1.25

23.1

1.7

29.0

2067

500

6x3x1.5

0.6

1.3

25.8

1.25

25.2

1.7

31.1

2361

500

7x3x1.5

0.6

1.3

25.8

1.25

25.2

1.7

31.1

2435

500

10x3x1.5

0.6

1.4

33.0

1.6

32.2

1.9

39.2

3526

500

12x3x1.5

0.6

1.4

34.1

1.6

33.3

1.9

40.3

3766

500

16x3x1.5

0.6

1.5

38.4

37.8

2.1

46.0

4965

500

20x3x1.5

0.6

1.6

43.0

42.2

2.2

50.6

5807

500

24x3x1.5

0.6

1.7

47.9

2.5

46.9

2.3

56.5

7213

500

30x3x1.5

0.6

1.8

51.0

2.5

50.2

2.4

60.0

8214

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)YKYRY , TiMF

mm

mm

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

Diameter Under
Armour

mm

Weight

Armour Wire
Diameter

mm

Overall
Diameter

Diameter Over
Lead Sheath

mm2

Sheath thickness

Nominal cross
section area of
conductor

Lead Sheath
Thickness

EN 50288-7 (500 V)
Insulation
thickness

Fire Resistant

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

1.0

13.1

0.9

13.1

1.5

17.9

914

1000

2x3x2.5

0.7

1.2

21.1

1.25

20.7

1.7

26.6

1775

1000

3x3x2.5

0.7

1.2

22.5

1.25

22.1

1.7

28.0

1976

1000

4x3x2.5

0.7

1.2

24.6

1.25

24.2

1.7

30.1

2237

500

5x3x2.5

0.7

1.3

27.1

1.25

26.5

1.8

32.6

2596

500

6x3x2.5

0.7

1.4

29.8

1.25

29.0

1.8

35.1

2976

500

7x3x2.5

0.7

1.4

29.8

1.25

29.0

1.8

35.1

3084

500

10x3x2.5

0.7

1.6

38.8

38.0

2.1

46.2

5035

500

12x3x2.5

0.7

1.6

40.1

39.3

2.1

47.5

5384

500

16x3x2.5

0.7

1.7

44.8

43.8

2.2

52.2

6394

500

20x3x2.5

0.7

1.8

50.5

2.5

49.7

2.4

59.5

8251

500

24x3x2.5

0.7

2.0

56.5

2.5

55.3

2.5

65.3

9655

250

30x3x2.5

0.7

2.0

59.8

3.15

58.6

2.6

70.1

11578

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)HKHRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

291

Kerman & Kavian Cable Industries ( KCI )

KCI
RE-2X(St)(L)2Y4YRY

EN 50288-7 (500 V)
RE-2X(St)(L)2Y4YRY Multi-Pair
RE-2X(St)(L)2Y4YRY Multi-Triple
RE-2X(St)(L)2Y4YRY PiMF
RE-2X(St)(L)2Y4YRY TiMF

Alternatively ; Low Smoke , Halogen free Type :

RE-2X(St)(L)2Y4YRH Multi-Pair
RE-2X(St)(L)2Y4YRH Multi-Triple
RE-2X(St)(L)2Y4YRH PiMF
RE-2X(St)(L)2Y4YRH TiMF

KCI

RE-2X(St)(L)2Y4YRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Collective (Overall )
Screen
Multi-Layer Sheath
Armour
Outer Sheath

+90 oC

IEC 60332-1

Instrument Cables

Criteria
Conductor cross section

Black,Blue (Numbered)

IEC 60708 Full color

XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Sheath + Polyamide Extruded Layer
Galvanized Steel Wires
Extruded PVC

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

294
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

11.6

1.4

16.2

427

1000

2x2x0.5

0.6

0.9

14.3

1.5

19.1

547

1000

3x2x0.5

0.6

0.9

14.8

1.5

19.6

583

1000

4x2x0.5

0.6

1.25

15.7

1.5

21.2

752

1000

5x2x0.5

0.6

1.25

16.7

1.5

22.2

805

1000

6x2x0.5

0.6

1.25

17.7

1.6

23.4

879

1000

7x2x0.5

0.6

1.25

17.7

1.6

23.4

894

1000

10x2x0.5

0.6

1.25

21.2

1.6

26.9

1087

500

12x2x0.5

0.6

1.6

21.7

1.7

28.3

1321

500

16x2x0.5

0.6

1.6

23.6

1.7

30.2

1467

500

20x2x0.5

0.6

1.6

25.8

1.8

32.6

1649

500

24x2x0.5

0.6

28.1

1.8

35.7

2073

500

30x2x0.5

0.6

29.5

1.9

37.3

2258

500

1x2x0.75

0.6

0.9

12.0

1.4

16.6

446

1000

2x2x0.75

0.6

0.9

15.0

1.5

19.8

583

1000

3x2x0.75

0.6

1.25

15.6

1.5

21.1

752

1000

4x2x0.75

0.6

1.25

16.6

1.5

22.1

812

1000

5x2x0.75

0.6

1.25

17.6

1.6

23.3

892

1000

6x2x0.75

0.6

1.25

18.8

1.6

24.5

956

1000

7x2x0.75

0.6

1.25

18.8

1.6

24.5

976

1000

10x2x0.75

0.6

1.6

22.6

1.7

29.2

1400

500

12x2x0.75

0.6

1.6

23.2

1.7

29.8

1470

500

16x2x0.75

0.6

1.6

25.2

1.8

32.0

1655

500

20x2x0.75

0.6

1.6

27.6

1.8

34.4

1869

500

24x2x0.75

0.6

30.1

1.9

37.9

2348

500

30x2x0.75

0.6

31.7

1.9

39.5

2581

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

295

KCI

RE-2X(St)(L)2Y4YRY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

12.4

1.4

17.0

468

1000

2x2x1

0.6

1.25

15.6

1.5

21.1

741

1000

3x2x1

0.6

1.25

16.2

1.5

21.7

790

1000

4x2x1

0.6

1.25

17.3

1.5

22.8

867

1000

5x2x1

0.6

1.25

18.4

1.6

24.1

944

1000

6x2x1

0.6

1.25

19.7

1.6

25.4

1025

500

7x2x1

0.6

1.25

19.7

1.6

25.4

1051

500

10x2x1

0.6

1.6

23.7

1.7

30.3

1510

500

12x2x1

0.6

1.6

24.4

1.7

31.0

1592

500

16x2x1

0.6

1.6

26.6

1.8

33.4

1820

500

20x2x1

0.6

29.2

1.9

37.0

2328

500

24x2x1

0.6

31.9

1.9

39.7

2593

500

30x2x1

0.6

33.6

2.0

41.6

2853

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

296

1x2x1.5

0.6

0.9

13.0

1.4

17.6

502

1000

2x2x1.5

0.6

1.25

16.6

1.5

22.1

804

1000

3x2x1.5

0.6

1.25

17.3

1.6

23.0

885

1000

4x2x1.5

0.6

1.25

18.5

1.6

24.2

976

1000

5x2x1.5

0.6

1.25

19.8

1.6

25.5

1069

500

6x2x1.5

0.6

1.25

21.1

1.6

26.8

1164

500

7x2x1.5

0.6

1.25

21.1

1.6

26.8

1202

500

10x2x1.5

0.6

1.6

25.7

1.8

32.5

1727

500

12x2x1.5

0.6

1.6

26.4

1.8

33.2

1850

500

16x2x1.5

0.6

28.9

1.9

36.7

2402

500

20x2x1.5

0.6

31.8

1.9

39.6

2715

500

24x2x1.5

0.6

2.5

35.3

2.0

44.3

3518

500

30x2x1.5

0.6

2.5

37.1

2.1

46.3

3883

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

14.2

1.5

19.0

577

1000

2x2x2.5

0.7

1.25

18.6

1.6

24.3

948

1000

3x2x2.5

0.7

1.25

19.5

1.6

25.2

1045

500

4x2x2.5

0.7

1.25

20.9

1.6

26.6

1163

500

5x2x2.5

0.7

1.6

22.5

1.7

29.1

1473

500

6x2x2.5

0.7

1.6

24.2

1.7

30.8

1632

500

7x2x2.5

0.7

1.6

24.2

1.7

30.8

1691

500

10x2x2.5

0.7

29.8

1.9

37.6

2438

500

12x2x2.5

0.7

30.7

1.9

38.5

2600

500

16x2x2.5

0.7

34.1

2.0

42.1

3079

500

20x2x2.5

0.7

2.5

38.0

2.1

47.2

4016

500

24x2x2.5

0.7

2.5

41.8

2.2

51.2

4520

250

30x2x2.5

0.7

3.15

44.1

2.3

55.0

5685

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)(L)2Y4YRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

297

KCI

RE-2X(St)(L)2Y4YRY
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Multi-Layer Sheath
Sheath + Polyamide Extruded Layer
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC

+90 oC

IEC 60332-1

Instrument Cables

Criteria
Conductor cross section

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

298
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

11.9

1.4

16.5

446

1000

2x3x0.5

0.6

0.9

15.3

1.5

20.1

596

1000

3x3x0.5

0.6

1.25

15.9

1.5

21.4

762

1000

4x3x0.5

0.6

1.25

16.9

1.5

22.4

834

1000

5x3x0.5

0.6

1.25

18.0

1.6

23.7

907

1000

6x3x0.5

0.6

1.25

19.2

1.6

24.9

983

500

7x3x0.5

0.6

1.25

19.2

1.6

24.9

1005

500

10x3x0.5

0.6

1.6

23.1

1.7

29.7

1443

500

12x3x0.5

0.6

1.6

23.7

1.7

30.3

1516

500

16x3x0.5

0.6

1.6

25.8

1.8

32.6

1727

500

20x3x0.5

0.6

28.3

1.8

35.9

2194

500

24x3x0.5

0.6

30.9

1.9

38.7

2455

500

30x3x0.5

0.6

32.6

1.9

40.4

2674

500

1x3x0.75

0.6

0.9

12.4

1.4

17.0

474

1000

2x3x0.75

0.6

1.25

16.0

1.5

21.5

771

1000

3x3x0.75

0.6

1.25

16.7

1.5

22.2

825

1000

4x3x0.75

0.6

1.25

17.9

1.6

23.6

917

1000

5x3x0.75

0.6

1.25

19.1

1.6

24.8

1002

500

6x3x0.75

0.6

1.25

20.4

1.6

26.1

1089

500

7x3x0.75

0.6

1.25

20.4

1.6

26.1

1120

500

10x3x0.75

0.6

1.6

24.7

1.7

31.3

1595

500

12x3x0.75

0.6

1.6

25.4

1.8

32.2

1716

500

16x3x0.75

0.6

27.7

1.8

35.3

2205

500

20x3x0.75

0.6

30.4

1.9

38.2

2503

500

24x3x0.75

0.6

33.3

2.0

41.3

2806

500

30x3x0.75

0.6

2.5

35.5

2.0

44.5

3549

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

299

KCI

RE-2X(St)(L)2Y4YRY

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

12.8

1.4

17.4

494

1000

2x3x1

0.6

1.25

16.7

1.5

22.2

809

1000

3x3x1

0.6

1.25

17.5

1.6

23.2

892

1000

4x3x1

0.6

1.25

18.7

1.6

24.4

985

1000

5x3x1

0.6

1.25

20.0

1.6

25.7

1081

500

6x3x1

0.6

1.25

21.4

1.6

27.1

1177

500

7x3x1

0.6

1.25

21.4

1.6

27.1

1217

500

10x3x1

0.6

1.6

26.0

1.8

32.8

1766

500

12x3x1

0.6

1.6

26.8

1.8

33.6

1876

500

16x3x1

0.6

29.3

1.9

37.1

2435

500

20x3x1

0.6

32.2

1.9

40.0

2757

500

24x3x1

0.6

2.5

35.7

2.0

44.7

3568

500

30x3x1

0.6

2.5

37.6

2.1

46.8

3945

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

300

1x3x1.5

0.6

0.9

13.4

1.4

18.0

535

1000

2x3x1.5

0.6

1.25

17.8

1.6

23.5

906

1000

3x3x1.5

0.6

1.25

18.7

1.6

24.4

999

1000

4x3x1.5

0.6

1.25

20.0

1.6

25.7

1112

500

5x3x1.5

0.6

1.25

21.5

1.7

27.4

1248

500

6x3x1.5

0.6

1.6

23.0

1.7

29.6

1541

500

7x3x1.5

0.6

1.6

23.0

1.7

29.6

1597

500

10x3x1.5

0.6

28.3

1.8

35.9

2311

500

12x3x1.5

0.6

29.1

1.9

36.9

2480

500

16x3x1.5

0.6

31.9

1.9

39.7

2867

500

20x3x1.5

0.6

2.5

35.6

2.0

44.6

3750

500

24x3x1.5

0.6

2.5

39.5

2.1

48.7

4298

500

30x3x1.5

0.6

2.5

41.6

2.2

51.0

4785

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

14.8

1.5

19.6

622

1000

2x3x2.5

0.7

1.25

20.2

1.6

25.9

1079

500

3x3x2.5

0.7

1.25

21.2

1.7

27.1

1218

500

4x3x2.5

0.7

1.6

22.8

1.7

29.4

1555

500

5x3x2.5

0.7

1.6

24.6

1.8

31.4

1741

500

6x3x2.5

0.7

1.6

26.5

1.8

33.3

1935

500

7x3x2.5

0.7

1.6

26.5

1.8

33.3

2023

500

10x3x2.5

0.7

33.3

2.0

41.3

2977

500

12x3x2.5

0.7

34.3

2.0

42.3

3227

500

16x3x2.5

0.7

2.5

38.2

2.1

47.4

4253

500

20x3x2.5

0.7

2.5

42.2

2.2

51.6

4921

250

24x3x2.5

0.7

3.15

46.8

2.4

57.9

6356

250

30x3x2.5

0.7

3.15

49.4

2.4

60.5

7078

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)(L)2Y4YRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

301

KCI

RE-2X(St)(L)2Y4YRY , PiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White (Numbered)

Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Multi-Layer Sheath
Armour
Outer Sheath

+90 oC

Instrument Cables

IEC 60708 Full color

XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Sheath + Polyamide Extruded Layer
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria
Conductor cross section

Black,Blue (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

302
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x2x0.5

0.6

0.9

12.0

1.4

16.6

447

1000

2x2x0.5

0.6

0.9

15.5

1.5

20.3

607

1000

3x2x0.5

0.6

1.25

16.2

1.5

21.7

779

1000

4x2x0.5

0.6

1.25

17.2

1.6

22.9

862

1000

5x2x0.5

0.6

1.25

18.4

1.6

24.1

927

1000

6x2x0.5

0.6

1.25

19.6

1.6

25.3

1004

500

7x2x0.5

0.6

1.25

19.6

1.6

25.3

1027

500

10x2x0.5

0.6

1.6

23.6

1.7

30.2

1476

500

12x2x0.5

0.6

1.6

24.3

1.7

30.9

1552

500

16x2x0.5

0.6

1.6

26.5

1.8

33.3

1766

500

20x2x0.5

0.6

29.0

1.9

36.8

2261

500

24x2x0.5

0.6

31.7

1.9

39.5

2513

500

30x2x0.5

0.6

33.4

2.0

41.4

2753

500

1x2x0.75

0.6

0.9

12.4

1.4

17.0

472

1000

2x2x0.75

0.6

1.25

16.3

1.5

21.8

771

1000

3x2x0.75

0.6

1.25

17.0

1.5

22.5

834

1000

4x2x0.75

0.6

1.25

18.1

1.6

23.8

925

1000

5x2x0.75

0.6

1.25

19.4

1.6

25.1

1009

500

6x2x0.75

0.6

1.25

20.7

1.6

26.4

1095

500

7x2x0.75

0.6

1.25

20.7

1.6

26.4

1124

500

10x2x0.75

0.6

1.6

25.1

1.8

31.9

1614

500

12x2x0.75

0.6

1.6

25.8

1.8

32.6

1720

500

16x2x0.75

0.6

28.2

1.8

35.8

2212

500

20x2x0.75

0.6

31.0

1.9

38.8

2504

500

24x2x0.75

0.6

34.4

2.0

42.4

2862

500

30x2x0.75

0.6

2.5

36.2

2.1

45.4

3567

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

303

KCI

RE-2X(St)(L)2Y4YRY , PiMF

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x2x1

0.6

0.9

12.7

1.4

17.3

489

1000

2x2x1

0.6

1.25

16.9

1.5

22.4

814

1000

3x2x1

0.6

1.25

17.7

1.6

23.4

893

1000

4x2x1

0.6

1.25

18.9

1.6

24.6

983

500

5x2x1

0.6

1.25

20.2

1.6

25.9

1074

500

6x2x1

0.6

1.6

21.6

1.7

28.2

1350

500

7x2x1

0.6

1.6

21.6

1.7

28.2

1385

500

10x2x1

0.6

1.6

26.4

1.8

33.2

1746

500

12x2x1

0.6

1.6

27.2

1.8

34.0

1848

500

16x2x1

0.6

29.7

1.9

37.5

2400

500

20x2x1

0.6

32.7

1.9

40.5

2705

500

24x2x1

0.6

2.5

36.3

2.0

45.3

3516

500

30x2x1

0.6

2.5

38.2

2.1

47.4

3867

500

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

304

1x2x1.5

0.6

0.9

13.3

1.4

17.9

523

1000

2x2x1.5

0.6

1.25

18.0

1.6

23.7

890

1000

3x2x1.5

0.6

1.25

18.8

1.6

24.5

973

500

4x2x1.5

0.6

1.25

20.2

1.6

25.9

1087

500

5x2x1.5

0.6

1.6

21.7

1.7

28.3

1376

500

6x2x1.5

0.6

1.6

23.2

1.7

29.8

1505

500

7x2x1.5

0.6

1.6

23.2

1.7

29.8

1551

500

10x2x1.5

0.6

28.5

1.9

36.3

2235

500

12x2x1.5

0.6

29.4

1.9

37.2

2372

500

16x2x1.5

0.6

32.2

1.9

40.0

2722

500

20x2x1.5

0.6

2.5

36.0

2.1

45.2

3585

500

24x2x1.5

0.6

2.5

39.9

2.1

49.1

4079

500

30x2x1.5

0.6

2.5

42.1

2.2

51.5

4550

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY , PiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x2x2.5

0.7

0.9

14.6

1.5

19.4

599

1000

2x2x2.5

0.7

1.25

20.2

1.6

25.9

1041

500

3x2x2.5

0.7

1.25

21.2

1.7

27.1

1161

500

4x2x2.5

0.7

1.6

22.9

1.7

29.5

1479

500

5x2x2.5

0.7

1.6

24.6

1.8

31.4

1646

500

6x2x2.5

0.7

1.6

26.6

1.8

33.4

1821

500

7x2x2.5

0.7

1.6

26.6

1.8

33.4

1889

500

10x2x2.5

0.7

33.3

2.0

41.3

2786

500

12x2x2.5

0.7

34.4

2.0

42.4

2999

500

16x2x2.5

0.7

2.5

38.2

2.1

47.4

3949

500

20x2x2.5

0.7

2.5

42.2

2.2

51.6

4540

250

24x2x2.5

0.7

3.15

46.9

2.4

58.0

5899

250

30x2x2.5

0.7

3.15

49.5

2.4

60.6

6507

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)(L)2Y4YRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

305

KCI

RE-2X(St)(L)2Y4YRY , TiMF
Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

Conductor

Stranded (class 2) Plain annealed copper wires


Color Coding (Options) :

Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Multi-Layer Sheath
Armour
Outer Sheath

+90 oC

Instrument Cables

Conductor cross section

XLPE
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Sheath + Polyamide Extruded Layer
Galvanized Steel Wires
Extruded PVC

IEC 60332-1

Criteria

Blue,White,Red (Numbered)

Screened

10x O.D

Standard Values

Armoured

Unit

Nominal

0.5

0.75

1.5

2.5

mm

Conductor DC Resistance
@ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x
km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

306
25

25

25

40

60

microH/
Ohm

Test voltage :
core to core

for 1
minute

2.0 kV A.C or 3.0 kV D.C

K.V

500

core to screen
Operating voltage U(rms)

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 0.5 mm2 (7x0.30 mm)


1x3x0.5

0.6

0.9

12.3

1.4

16.9

466

1000

2x3x0.5

0.6

1.25

16.6

1.5

22.1

790

1000

3x3x0.5

0.6

1.25

17.3

1.6

23.0

864

1000

4x3x0.5

0.6

1.25

18.5

1.6

24.2

949

1000

5x3x0.5

0.6

1.25

19.8

1.6

25.5

1035

500

6x3x0.5

0.6

1.25

21.2

1.6

26.9

1123

500

7x3x0.5

0.6

1.25

21.2

1.6

26.9

1154

500

10x3x0.5

0.6

1.6

25.8

1.8

32.6

1676

500

12x3x0.5

0.6

1.6

26.5

1.8

33.3

1769

500

16x3x0.5

0.6

29.0

1.9

36.8

2293

500

20x3x0.5

0.6

31.9

1.9

39.7

2579

500

24x3x0.5

0.6

2.5

35.4

2.0

44.4

3354

500

30x3x0.5

0.6

2.5

37.3

2.1

46.5

3679

500

1x3x0.75

0.6

0.9

12.8

1.4

17.4

495

1000

2x3x0.75

0.6

1.25

17.5

1.6

23.2

855

1000

3x3x0.75

0.6

1.25

18.3

1.6

24.0

931

1000

4x3x0.75

0.6

1.25

19.6

1.6

25.3

1026

500

5x3x0.75

0.6

1.25

21.0

1.6

26.7

1124

500

6x3x0.75

0.6

1.6

22.5

1.7

29.1

1413

500

7x3x0.75

0.6

1.6

22.5

1.7

29.1

1453

500

10x3x0.75

0.6

1.6

27.5

1.8

34.3

1852

500

12x3x0.75

0.6

28.3

1.8

35.9

2225

500

16x3x0.75

0.6

31.0

1.9

38.8

2557

500

20x3x0.75

0.6

34.6

2.0

42.6

2963

500

24x3x0.75

0.6

2.5

38.3

2.1

47.5

3793

500

30x3x0.75

0.6

2.5

40.4

2.2

49.8

4219

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Conductor : 0.75 mm2 (7x0.37 mm)

307

KCI

RE-2X(St)(L)2Y4YRY , TiMF

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

Kerman & Kavian Cable Industries ( KCI )

EN 50288-7 (500 V)

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)


1x3x1

0.6

0.9

13.1

1.4

17.7

515

1000

2x3x1

0.6

1.25

18.2

1.6

23.9

905

1000

3x3x1

0.6

1.25

19.0

1.6

24.7

991

500

4x3x1

0.6

1.25

20.4

1.6

26.1

1097

500

5x3x1

0.6

1.6

22.0

1.7

28.6

1388

500

6x3x1

0.6

1.6

23.6

1.7

30.2

1518

500

7x3x1

0.6

1.6

23.6

1.7

30.2

1567

500

10x3x1

0.6

29.0

1.9

36.8

2283

500

12x3x1

0.6

29.8

1.9

37.6

2424

500

16x3x1

0.6

32.7

1.9

40.5

2781

500

20x3x1

0.6

2.5

36.5

2.1

45.7

3667

500

24x3x1

0.6

2.5

40.5

2.1

49.7

4169

500

30x3x1

0.6

2.5

42.7

2.2

52.1

4611

250

Instrument Cables

Conductor : 1.5 mm2 (7x0.53 mm)

308

1x3x1.5

0.6

0.9

13.8

1.5

18.6

563

1000

2x3x1.5

0.6

1.25

19.4

1.6

25.1

997

500

3x3x1.5

0.6

1.25

20.4

1.6

26.1

1101

500

4x3x1.5

0.6

1.6

21.9

1.7

28.5

1411

500

5x3x1.5

0.6

1.6

23.6

1.7

30.2

1560

500

6x3x1.5

0.6

1.6

25.4

1.8

32.2

1741

500

7x3x1.5

0.6

1.6

25.4

1.8

32.2

1807

500

10x3x1.5

0.6

31.4

1.9

39.2

2589

500

12x3x1.5

0.6

32.4

1.9

40.2

2793

500

16x3x1.5

0.6

2.5

36.0

2.1

45.2

3704

500

20x3x1.5

0.6

2.5

40.2

2.2

49.6

4300

500

24x3x1.5

0.6

3.15

44.2

2.3

55.1

5496

250

30x3x1.5

0.6

3.15

47.0

2.4

58.1

6212

250

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

RE-2X(St)(L)2Y4YRY , TiMF

mm

mm

Kg/Km

meter

Kerman & Kavian Cable Industries ( KCI )

mm

Standard
Packing Length

mm

Weight

Diameter Under
Armour

mm

Overall
Diameter

Armour Wire
Diameter

mm2

Sheath thickness

Nominal cross section


area of conductor

Insulation
thickness

EN 50288-7 (500 V)

Conductor : 2.5 mm2 (7x0.67 mm)


1x3x2.5

0.7

0.9

15.1

1.5

19.9

650

1000

2x3x2.5

0.7

1.6

21.9

1.7

28.5

1349

500

3x3x2.5

0.7

1.6

23.1

1.7

29.7

1504

500

4x3x2.5

0.7

1.6

25.0

1.8

31.8

1719

500

5x3x2.5

0.7

1.6

27.0

1.8

33.8

1926

500

6x3x2.5

0.7

29.2

1.9

37.0

2405

500

7x3x2.5

0.7

29.2

1.9

37.0

2503

500

10x3x2.5

0.7

2.5

36.8

2.1

46.0

3705

500

12x3x2.5

0.7

2.5

38.4

2.1

47.6

4035

500

16x3x2.5

0.7

2.5

42.3

2.2

51.7

4743

250

20x3x2.5

0.7

3.15

47.3

2.4

58.4

6228

250

24x3x2.5

0.7

3.15

52.5

2.5

63.8

7125

250

30x3x2.5

0.7

3.15

55.5

2.6

67.0

8013

250

Additional Options (by request)

Reduced smoke PVC


Tested acc to ASTM E662 &
Improved Flame Retardant
acc to IEC 60332-3

Oil & Chemical


Resistant PVC Sheath
Acc to ICEA S-82-552
(Equal to NEMA WC55)

B) Based on Halogen Free Construction

Low Halogen Acid & Gas


acc to IEC 60754-1&2
IEC 60502 ST8

www.kermancableind.com

UV Resistant PVC Sheath


Acc to UL 1581-1200

Cable Type : RE-2X(St)(L)2Y4YRH

Low smoke
Acc to IEC 61034

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

A) Based on PVC Sheath

309

Kerman & Kavian Cable Industries ( KCI )

KCI
Railway Signal Cable
VDE 0816-2
A-2YYBY
AJ-2Y(St)YBY Multi-Core
AJ-2YDYBY Multi-Core
AJ-2Y(St)YBY Multi-Quad
AJ-2YDYBY Multi-Quad

KCI

Kerman & Kavian Cable Industries ( KCI )

A Summary of VDE 0816


Outdoor cables for telecommunication and information systems , Signalling and
Measuring cables and Mine cables .
Scope
This Standard applies to outdoor cables for telecommunications and information processing systems,
divided into the types signalling and measuring cable and mine cable.
It does not apply to cables in respect of the make-up and properties of which special requirements are laid
down for electrical or mechanical reasons.
Signalling and measuring cables :
The cables are stranded in layers and contain as stranding components cores with copper conductors 0.9 or
1.4 or 1.8 mm in diameter. The conductor insulation is of PE .

1) Conductor
The conductor is plain solid annealed copper ; usually 0.9 , 1.4 mm (0.8 , 1.8 mm also available).
The conductors must be of soft copper and of completely satisfactory quality, The breaking elongation
of the conductors in the cable must be at least 15%. Any joints present must not impair the completely
satisfactory nature of the conductor. The tensile strength of a joint within a conductor must be at least 90%
of the tensile strength of that conductor without a joint.

2) Insulation
The PE insulation must comply with compound 2YI1 in accordance with DIN
VDE 0207

Instrument Cables

PE : Polyethylene

3)Cabling element
A cabling element shall be
an insulated conductor (core) to build up a multi-core cable
a pair of two insulated conductors twisted together and designated wire a and wire b
a quad (star quad) of four insulated conductors twisted together and designated wire a, wire b, wire c
and wire d respectively.
The stranding components are counted successively in the same direction through all the layers, starting
with the first layer (inner layer). In doing this, start from the initial component in each layer

312

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI
Kerman & Kavian Cable Industries ( KCI )

4)Stranding
The cable elements shall be formed into a number of sub-units or units which can be stranded into a regular
make up to produce the required number of cores , pairs or Quads .
5)Filling
For filled cables (if Requested) , the interstices of the cable core shall be filled continuously with a
compound suitable to prevent water penetration within the cable.

6)Core protection
The core of the cable may have a protective layer (e.g. a helical or longitudinal lapping of one or more tapes).
7)Shield (protection against electromagnetic fields)
The Shield of cable is selected to comply requirements of requested reduction factor . It could be ;
Copper Tapes or Copper Wires .

Tape

Wires

8)Armour (protection against mechanical damages)


When required by the relevant sectional specification the armouring shall consist of
one or more of the following:
8-1) layer of round galvanised steel wires;
8-2) single or a double layer of steel tape

Tape Armour
Instrument Cables

Wire Armour

9)Sheath
The inner-sheath and outer-sheath of cable is usually PVC.
The PVC sheath must comply with compound type YM1 in accordance
with DIN VDE 0207 Part 5.
-Optional : A moisture barrier aluminium laminated polyethylene sheath
construction is specified for both underground and aerial cables. This type
of sheath will also provide screening.

Aluminium Tape bonded


to Polyethylene sheath

313

-Optional : A lead sheath could be provided for extra shield and protection
against penetration of liquids and chemicals to cable core.
Lead Sheath (Lead Cover)

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

KCI

Kerman & Kavian Cable Industries ( KCI )

A-2YYBY
Construction :
Conductor
Insulation

Solid plain annealed copper


HDPE
All cores are gray except one blue core in each
layer as tracer
PVC
Galvanized Steel Tapes
PVC

Color Code
Bedding
Armour
Sheath

Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)

Characteristics

Conductor Size

Standard value

0.9 mm

Max 28.9

1.4 mm

Max 11.9
Min 5

Gohm x km

0.9 mm

Max 100

1.4 mm

Max 120

nF/km
at 800 - 1000 Hz

Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance

Unit
Ohm/kM

Dielectric strength
2

Number of Cores x
Conductor Diameter

Armour Tape
Thickness

Sheath thickness

Overall
Diameter

Weight

Standard
Packing Length

2500

Diameter Under
Armour

Instrument Cables

314

Veff & duration :


minutes

2500

wire/wire
wire/screen

mm

mm

mm

mm

mm

Kg/Km

meter

2x1x0.9 S(2B0.5)

8.1

0.5

2.6

15.3

398

1000

4x1x0.9 S(2B0.5)

8.9

0.5

2.6

16.1

443

1000

6x1x0.9 S(2B0.5)

9.8

0.5

2.6

17.0

499

1000

8x1x0.9 S(2B0.5)

11.1

0.5

2.6

18.3

569

1000

12x1x0.9 S(2B0.5)

12.2

0.5

2.6

19.4

640

1000

30x1x0.9 S(2B0.5)

16.3

0.5

2.6

23.5

945

1000

50x1x0.9 S(2B0.5)

20.1

0.5

2.6

27.3

1261

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI
Kerman & Kavian Cable Industries ( KCI )

A-2YYBY
Construction :
Conductor
Insulation

Solid plain annealed copper


HDPE
All cores are gray except one blue core in each
layer as tracer
PVC
Galvanized Steel Tapes
PVC

Color Code
Bedding
Armour
Sheath

Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)

Characteristics

Conductor Size

Standard value

0.9 mm

Max 28.9

1.4 mm

Max 11.9
Min 5

Gohm x km

0.9 mm

Max 100

1.4 mm

Max 120

nF/km
at 800 - 1000 Hz

Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance

Unit
Ohm/kM

Dielectric strength
2500

Veff & duration :


minutes

Sheath thickness

Overall
Diameter

Weight

Standard
Packing Length

mm

mm

mm

mm

mm

Kg/Km

meter

4x1x1.4

10.4

0.5

2.6

17.6

543

1,000

5x1x1.4

11.2

0.5

2.6

18.4

593

1,000

8x1x1.4

12.4

0.5

1.8

18.0

622

1,000

10x1x1.4

14.5

0.5

2.6

21.7

813

1,000

16x1x1.4

16.4

0.5

2.6

23.6

995

1,000

20x1x1.4

18.0

0.5

2.6

25.2

1135

500

30x1x1.4

20.8

0.5

2.6

28.0

1416

500

33x1x1.4

21.6

0.5

2.6

28.8

1504

500

40x1x1.4

23.2

0.5

2.6

30.4

1685

500

50x1x1.4

26.0

0.5

2.6

33.2

1986

500

56x1x1.4

26.8

0.5

2.6

34.0

2117

500

60x1x1.4

27.5

0.5

2.6

34.7

2217

500

65x1x1.4

28.4

0.5

2.6

35.6

2337

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Number of Cores x
Conductor Diameter

Armour Tape
Thickness

2500

Diameter Under
Armour

wire/wire
wire/screen

315

KCI

Kerman & Kavian Cable Industries ( KCI )

AJ-2Y(St)YBY
Construction :
Conductor
Insulation

Solid plain annealed copper


HDPE
All cores are gray except one blue core in each
layer as tracer
PVC
Copper Tape
PVC
Galvanized Steel Tapes
PVC

Color Code
Inner Covering
Shield
Bedding
Armour
Sheath

Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics

Conductor Size

Standard value

0.9 mm

Max 28.9

1.4 mm

Max 11.9

Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance

Unit
Ohm/kM

Min 5

Gohm x km

0.9 mm

Max 100

1.4 mm

Max 120

nF/km
at 800 - 1000 Hz

Dielectric strength
2

Number of Cores x
Conductor Diameter

Armour Tape
Thickness

Sheath thickness

Overall
Diameter

Weight

Standard
Packing Length

2500

Diameter Under
Armour

Instrument Cables

316

Veff & duration :


minutes

2500

wire/wire
wire/screen

mm

mm

mm

mm

mm

Kg/Km

meter

2x1x0.9 S(2B0.5)

9.1

0.5

1.8

14.7

412

1000

4x1x0.9 S(2B0.5)

9.9

0.5

1.8

15.5

458

1000

8x1x0.9 S(2B0.5)

12.2

0.5

1.8

17.8

590

1000

12x1x0.9 S(2B0.5)

13.2

0.5

1.8

18.8

659

1000

8x1x1.4 S(2B0.5)

14.7

0.5

1.8

20.3

4373

1,000

12x1x1.4 S(2B0.5)

16.1

0.5

1.8

21.7

896

1,000

16x1x1.4 S(2B0.5)

17.6

0.5

1.8

23.2

896

1,000

21x1x1.4 S(2B0.5)

19.2

0.5

2.0

25.2

1203

1,000

27x1x1.4 S(2B0.5)

21.3

0.5

2.0

27.3

1203

1,000

33x1x1.4 S(2B0.5)

22.8

0.5

2.0

28.8

1203

1,000

40x1x1.4 S(2B0.5)

25.2

0.5

2.0

31.2

1203

500

48x1x1.4 S(2B0.5)

27.3

0.5

2.0

33.3

1203

500

56x1x1.4 S(2B0.5)

28.8

0.5

2.2

35.2

2306

500

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI
Kerman & Kavian Cable Industries ( KCI )

AJ-2YDYBY
Construction :
Conductor
Insulation

Solid plain annealed copper


HDPE
All cores are gray except one blue core in each
layer as tracer
PVC
Copper Wires
PVC
Galvanized Steel Tapes
PVC

Color Code
Inner Covering
Shield
Bedding
Armour
Sheath

Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics

Conductor Size

Standard value

0.9 mm

Max 28.9

1.4 mm

Max 11.9

Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance

Unit
Ohm/kM

Min 5

Gohm x km

0.9 mm

Max 100

1.4 mm

Max 120

nF/km
at 800 - 1000 Hz

Dielectric strength
2500

Veff & duration :


minutes

Sheath thickness

Overall
Diameter

Weight

Standard
Packing Length

mm

mm

mm

mm

mm

Kg/Km

meter

2x1x0.9 S(2B0.5)

11.1

0.5

1.8

16.7

412

1000

4x1x0.9 S(2B0.5)

11.9

0.5

1.8

17.5

699

1000

8x1x0.9 S(2B0.5)

14.2

0.5

1.8

19.8

886

1000

12x1x0.9 S(2B0.5)

15.2

0.5

1.8

20.8

971

1000

16x1x0.9 S(2B0.5)

16.3

0.5

2.0

22.3

1180

1000

12x1x1.4 S(2B0.5)

18.1

0.5

2.0

24.1

1292

1,000

16x1x1.4 S(2B0.5)

19.6

0.5

2.0

25.6

1463

1,000

21x1x1.4 S(2B0.5)

21.2

0.5

2.0

27.2

1203

1,000

27x1x1.4 S(2B0.5)

24.1

0.5

2.0

30.1

1203

1,000

33x1x1.4 S(2B0.5)

25.6

0.5

2.0

31.6

1203

500

40x1x1.4 S(2B0.5)

27.2

0.5

2.0

33.2

1203

500

48x1x1.4 S(2B0.5)

29.3

0.5

2.2

35.7

1203

500

56x1x1.4 S(2B0.8)

30.8

0.8

2.2

38.4

2306

500

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Number of Cores x
Conductor Diameter

Armour Tape
Thickness

2500

Diameter Under
Armour

wire/wire
wire/screen

317

KCI

Kerman & Kavian Cable Industries ( KCI )

AJ-2Y(St)YBY
Construction :
Conductor
Insulation

Solid plain annealed copper


HDPE
Quad : Yellow+Red , Green+Blue , All quads are
distinguished by colored binders
PVC
Copper Tape
PVC
Galvanized Steel Tapes
PVC

Color Code
Inner Covering
Shield
Bedding
Armour
Sheath

Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)

Characteristics

Conductor Size

Standard value

Unit

0.9 mm
1.4 mm

Max 56.6
Max 23.4
Min 5
Max 45
Max 50

Ohm/kM

Conductor Loop
resistance, max.
Insulation resistance

0.9 mm
1.4 mm

Mutual capacitance

Gohm x km
nF/km
at 800 - 1000 Hz

Dielectric strength
wire/wire
wire/screen

Veff & duration :


2 minutes

2500
2500

at 800 - 1000 Hz

between quads and earth (E1)

Max 800

Number of Cores x
Conductor Diameter

Standard
Packing Length

Max 100

Weight

between non-adjacent quads (K9 ~ K12)

Overall
Diameter

pf/300 m

Sheath thickness

Max 400
Max 300

Armour Tape
Thickness

Within quads (K1)


between adjacent quads (K9 ~ K12)

Diameter Under
Armour

Instrument Cables

Capacitance unbalance

mm

mm

mm

mm

mm

Kg/Km

meter

1x4x1.4 S(2B0.5)

15.2

0.5

2.6

22.4

880

1000

3x4x1.4 S(2B0.5)

21.3

0.5

2.6

28.5

1371

1000

5x4x1.4 S(2B0.5)

24.5

0.5

2.6

31.7

1719

1000

7x4x1.4 S(2B0.5)

26.3

0.5

2.6

33.5

1949

1,000

8x4x1.4 S(2B0.5)

28.0

0.5

2.6

35.2

2121

1,000

10x4x1.4 S(2B0.5)

30.6

0.5

2.6

37.8

2414

1,000

318

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI
Kerman & Kavian Cable Industries ( KCI )

AJ-2YDYBY
Construction :
Conductor
Insulation

Solid plain annealed copper


HDPE
Quad : Yellow+Red , Green+Blue , All quads are
distinguished by colored binders
PVC
Copper Wires
PVC
Galvanized Steel Tapes
PVC

Color Code
Inner Covering
Shield
Bedding
Armour
Sheath

Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)

Characteristics

Conductor Size

Standard value

Unit

0.9 mm
1.4 mm

Max 56.6
Max 23.4
Min 5
Max 45
Max 50

Ohm/kM

Conductor Loop
resistance, max.
Insulation resistance
Mutual capacitance

0.9 mm
1.4 mm

Gohm x km
nF/km
at 800 - 1000 Hz

Dielectric strength
wire/wire
wire/screen

Veff & duration :


2 minutes

2500
2500

between quads and earth (E1)

Max 800

Number of Cores x
Conductor Diameter

Standard
Packing Length

at 800 - 1000 Hz

Weight

Max 100

Overall
Diameter

between non-adjacent quads (K9 ~ K12)

Sheath thickness

pf/300 m

Armour Tape
Thickness

Max 400
Max 300

Diameter Under
Armour

Within quads (K1)


between adjacent quads (K9 ~ K12)

mm

mm

mm

mm

mm

Kg/Km

meter

1x4x1.4 S(2B0.5)

13.9

0.5

1.8

19.5

567

1000

3x4x1.4 S(2B0.5)

19.3

0.5

2.0

25.3

931

1000

5x4x1.4 S(2B0.5)

22.8

0.5

2.0

28.8

931

1000

7x4x1.4 S(2B0.5)

29.6

0.5

2.2

36.0

2199

1000

8x1x1.4 S(2B0.5)

16.7

0.5

1.8

22.3

4373

1000

10x4x1.4 S(2B0.8)

33.8

0.8

2.2

41.4

2096

1000

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Instrument Cables

Capacitance unbalance

319

Kerman & Kavian Cable Industries ( KCI )

KCI
Appendix
Used Symbols (In cables datasheets)
Color Coding of pairs acc to IEC 60708 , 60189
Shield Effectiveness
SCREEN Selection guide for Instrument cables
Types of Noise and Their Effects on the cables
Reduction Factor of Screen

KCI

Kerman & Kavian Cable Industries ( KCI )

Used Symbols (In cables datasheets)

Minumum Bending Radius

Mechanical Protection

Maximum Conductor Temperature

Improved Flame Retardant

Fire Resistant

Low Smoke

Instrument Cables

Protection against Chemicals

Flame Retardant

Flexibility

Low Halogen Acid/Gas

322

Protection against
Electromagnetic Fields

UV / Weather Resistant

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

Wire a

Wire b

Blue

Orange

White

Green

Brown

Grey

Blue

Orange

Red

Green

Brown

10

Grey

11

Blue

12

Orange

13

Black

Green

14

Brown

15

Grey

16

Blue

17

Orange

18

Yellow

Green

19

Brown

20

Grey

21

Blue

22

Orange

23

Violet

Green

24

Brown

25

Grey

Instrument Cables

Pair No

Kerman & Kavian Cable Industries ( KCI )

KCI

Color Coding of pairs acc to IEC 60708 , 60189

323

www.kermancableind.com

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

KCI

Shield Effectiveness
Kerman & Kavian Cable Industries ( KCI )

Transfer Impedance
Transfer impedance is a fundamental value of a shields Performance.
Transfer impedance relates a current on one surface of the shield To the voltage drop generated by this current
on the opposite surface of the shield. This value depends solely on the shield
construction.
Transfer impedance test data is obtained with a terminated Triaxial test fixture. This test method, which is a
modification of An existing IEC test procedure, is the one that was proposed by Kenneth Simons.

Transfer Impedance Measurement


Above Figure illustrates the relationship between the radiated and transfer impedance methods. In the
radiated case (A), an antenna-coupled EF induces current into the RF gasket material. For transfer impedance
measurements (B), a signal generator is used. The Zst is a complex quantity that combines the materials DC
surface resistance (Rs) and its surface inductive reactance (Xsl).

Instrument Cables

Transfer Impedance is defined as:

Zt = ( 1 / I0 ) x ( dV / dx )

Where I0 is a longitudinal disturbing current generated on one surface (either the inner or the outer surface)
of the shield and dv /dx is the longitudinal voltage per unit length, generated by I0 , appearing on the opposite
surface of the shield.
In the terminated triaxial test system, the test cable center conductor and the shield form an inner terminated
triaxial test system, the test cable center conductor and the shield form an inner transmission system, with the
shield and the outer concentric tube forming an outer transmission system .
The outer system is driven by a generator and creates a current I0 on the outer surface of the shield. This
current causes a voltage difference on the opposite surface shown as V1, and V2 over a length of shield X.
This generates signals in the test cable which can be related to the transfer impedance value of the shield.

324

Conclusion :
The lower the value of the transfer impedance, the more effective the shielding.
The transfer impedance value theoretically can be used to determine absolute interference levels.

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

Recommendation Table for best choice of Instrument cables Screen Type


Cable Type
Non-Armoured
Overall Screened
Non-Armoured
Individual Screened
Armoured
Overall Screened
Armoured
Individual Screened

www.kermancableind.com

Low frequency
performance

High frequency
performance

Good

----

Good

Good

Excellent

Good

Excellent

Excellent

Instrument Cables

Kerman & Kavian Cable Industries ( KCI )

SCREEN Selection guide for Instrument cables

325

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

Types of Noise and Their Effects on the cables

KCI

Kerman & Kavian Cable Industries ( KCI )

For transducer connection to the instrument , the cable transmits a very low e.m.f. signal.
A noise free signal is important to avoid mistakes.
Thus the cable must be screened against static or magnetic fields which can induce unwanted e.m.f.
There are four different sources of noise, as follows:

Static Noise
This is interference caused by coupling of capacity
between
external electrical field from power line or another
voltage source and the cable. Interposing a single shield
which forms a capacitor when connected to the earth.
A shield of aluminium/polyester, 100% coverage is
recommended.

Magnetic Noise
Generally low frequency electromagnetic field due
to power cable, motor, ctc. Can induce e.m.f. into the
instrumentation cable. The twisting of conductors provides
a good reduction of the magnetic noise. Other reduction
are given by steel conduit, armours (high inductance
material).Is some particular cases low resisting screen(i.e.
copper braids, copper tapes) may be necessary.

Common-Mode Noise

Instrument Cables

This is typical interference caused when the instrumentation


loop is earthed on two sides with different potential.
To avoid this noise the shield, instrument or hot junction of
thermocouple must be commonly earthed.

Cross Talk Noise


326

This is caused by unbalanced capacitance from adjacent


cabling elements of different construction .
To reduce this noise for pair/triad/quad cables,
differing lay of twist is used or more effectively
each pair/triad/quad is individually shielded
(i.e. aluminium/polyester 100% coverage) and commonly
earthed.

Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

KCI

Reduction Factor of Screen

Kerman & Kavian Cable Industries ( KCI )

External interference
Screening against external interference has to take the influence of both electric and magnetic interference into
account and make a distinction between LF and HF fields.The design of the required screen depends on the
type and strength of interference.

Screening in the LF-range


For screening in the LF-range i.e. in the range of frequencies of up to 10kHz the influence of both electric
and magnetic interference can be examined separately. Interference from electric fields can be virtually
disregarded if conductive screens are used; the lower the dc resistance, the better the screening effect;
however, care must be taken to ensure a high degree of coverage as the electric field may otherwise affect
the cable core.Screening against LF magnetic interference requires the use of magnetic materials such as
steel wires or(even better) tapes. Materials of high permeability should be used for high levels of screening.
The measure of the effect of the screening in the LF range is the reduction factor. This is the ratio of the
interference voltage with a screen to the interference voltage without a screen and is calculated according to
the following formula:

The lower the rc the better the screening effect.

Screening in the HF- range


Screening in the HF range is based on energy losses due to electromagnetic interference caused by absorption
and reflection in or on the Screening material. The measure for the effect of screening in the HF range is the
coupling resistance, which is defined as follows

The coupling resistance depends on the frequency.


Above figure is typical curve of the coupling resistance

Requirements for effective screening in the HF-range are basically a low DC resistance and maximum
coverage of the screen .

Reduction factor
rc
rc > 0.9

Characteristic of Screening
Material
High DC resistance

rc =0.9 0.7

Low DC resistance

rc = 0.7 0.3

Low DC resistance in
combination of high inductance

rc < 0.3

Very low DC resistance , very


high inductance

www.kermancableind.com

Instrument Cables

The lower the rc the better the screening effect.

Screen Construction and Material


Aluminum laminated polyester tape
Copper Wire Braid
Concentric layers of copper wires
Respectively tapes
Layers of copper wires
Respectively copper tapes
Additionally steel armour / tapes
Layers of copper wires
Respectively copper tapes
Additionally steel armour / tapes
With high permeability

Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

327

Potrebbero piacerti anche