Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Contents
An Introduction to Kerman & Kavian Cable Industries (KCI)
RE-2X(St)Y
RE-2X(St)H
Page : 13
RE-YCY
RE-2XCH
Page : 35
RE-2X(St)YQY
RE-2X(St)HQH
Page : 57
RE-2X(St)HQHFire Resistant
Page : 79
RE-Y(St)Y
RE-2X(St)H
Page : 107
RE-2X(St)YFire Resistant
RE-2X(St)HFire Resistant
Page : 129
RE-Y(St)YRY
RE-2X(St)HRH
Page : 151
RE-Y(St)YRY , ..iMFY
RE-2X(St)HRH , ..iMFH
Page : 173
RE-2X(St)YRYFire Resistant
RE-2X(St)HRHFire Resistant
Page : 183
RE-Y(St)YBY
RE-2X(St)HBH
Page : 205
RE-2X(St)YBYFire Resistant
RE-2X(St)HBHFire Resistant
Page : 227
RE-Y(St)YKYRY
RE-2X(St)HKHRH
Page : 249
RE-2X(St)YKYRYFire Resistant
RE-2X(St)HKHRHFire Resistant
Page : 271
RE-2X(St)(L)2Y4YRY
RE-2X(St)(L)2Y4YRH
Page : 293
Appendixes
Cable protection against noise & Screen selection
Page : 314
KCI
KERMAN CABLE INDUSTRIES (KCI) was established in 1984 by co-operation of a team of experts in
industrial estate no.1 of Kerman. In the first phase, KCI had 5000 m2 production area in the land having 20000
m2 for manufacturing several types of cables.
In the second phase, KCI increased the production area to 20000 m2 in the land having area of 60000 m2.
KCI is active in the field of cable production with modern European machinery and with 400 personnel. The
nominal production capacity of the factory is 13600 metric tons of cable products per year.
Instrument Cables
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
Kerman & Kavian Cable Industries ( KCI )
In order to accomplish main expansion phase of Kerman Cable Industries and by having the background of
30 years experiment in cable industry, KAVIAN CABLE INDUSTRIES(KCI) was established in 1996 in
KAVEH industrial estate (near to SAVEH city). KCI has 17000 m2 of production area in the land having area
of 90000 m2. KCI now is active in the field of cable production with modern European machinery and with
100 personnel. The nominal production capacity of the factory is 17000 metric tons of cable products per year.
As there are considerable sources of cables main raw materials
(such as copper, pvc, steel, lead,) in IRAN and in the other side
there are huge requirements of wire and cable in IRAN , KAVIAN
CABLE INDUSTRIES (KCI) was established by a team of experts
in technical, research and quality control matters .
Instrument Cables
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
KCI
KCI
1 ) Conductors :
The material, metal coating, separator, class and form of the conductors shall be in accordance with IEC
60092-350 and shall be circular Class 2 or Class 5 constructions of cross-sectional area
0.50 mm2, 0.75 mm2, 1.0 mm2, 1.5 mm2 or 2.5 mm2.
Instrument Cables
Note : The preferred conductor sizes are 0.75 mm2 and 1.5 mm2.
Class 2 Stranding
Nominal cross
section of
conductors (mm2)
Class 5 Stranding
DC resistance of (conductors)
plain copper
tinned copper
plain copper
tinned copper
Ohm/kM at 20C
8
0.5
40.4
41.6
41.4
42.5
0.75
26
26.3
27.6
28.3
1.0
19.2
19.3
20.7
21.2
1.5
12.8
12.9
14.1
14.5
2.5
7.86
8.02
8.47
8.71
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
2 ) Insulation system
The insulation system shall consist of either;
2-1 ) one of the insulating compounds indicated in following Table
2-2) a combination of one or more layers of inorganic tape(s) and a layer of one of the insulating
compounds indicated in following Table (example Mica-Glass Tape + XLPE )
PVC/A
EPR
XLPE
HEPR
HF 85
S 95
mm2
mm
mm
mm
mm
mm
mm
0.5
0.6
0.6
0.4
0.4
0.6
0.6
0.75
1.0
1.5
2.5
0.6
0.6
0.7
0.7
0.6
0.6
0.7
0.7
0.5
0.5
0.6
0.6
0.5
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.6
0.6
0.7
0.7
Instrument Cables
Nominal
cross
section of
conductors
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
KCI
3 ) Cabling
Core (Unit)
Pair (Unit)
Triple (Unit)
Wire a
Wire b
Wire c
Wire d
Pair unit
Triple unit
Quad unit
Black
Black
Black
White
White
White
Red
Red
Blue
Instrument Cables
4 ) Electrostatic screen
10
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
mm2
Ohm/km
0.5
61.2
0.75
42.5
1.0
28.3
1.5
28.3
2.5
21.2
Braid (Screen)
6 ) Sheath(s)
Could be one of following materials ; PVC , PE , Halogen Free .
The sheath shall be coloured black or grey unless otherwise specified.
Note : The sheath may be of other colours, thereby providing a visual difference to
that of LV and MV Power cables.
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
Note : In the case of plain or tinned copper wire braids, these may also provide the function of an electrostatic
collective screen providing they are terminated to earth.
11
KCI
RE-2X(St)Y
IEC 60092-376
RE-2X(St)Y
Multi-Core
RE-2X(St)Y
Multi-Pair
RE-2X(St)Y
Multi-Triple
RE-2X(St)Y
PiMF
RE-2X(St)Y
TiMF
150/250 V (300 V)
RE-2X(St)H
RE-2X(St)H Multi-Core
RE-2X(St)H Multi-Pair
RE-2X(St)H Multi-Triple
RE-2X(St)H PiMF
RE-2X(St)H TiMF
KCI
RE-2X(St)Y
150/250 V (300 V)
IEC 60092-376
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+90 oC
Instrument Cables
14
XLPE
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
1.0
5.7
48
1000
3x0.5
0.4
1.0
6.0
56
1000
4x0.5
0.4
1.0
6.4
64
1000
5x0.5
0.4
1.0
6.9
73
1000
6x0.5
0.4
1.0
7.4
82
1000
7x0.5
0.4
1.0
7.4
88
1000
8x0.5
0.4
1.1
8.6
103
1000
10x0.5
0.4
1.1
9.3
119
1000
12x0.5
0.4
1.1
9.6
133
1000
16x0.5
0.4
1.1
10.5
163
1000
20x0.5
0.4
1.2
11.7
199
1000
24x0.5
0.4
1.2
12.9
231
1000
30x0.5
0.4
1.3
13.8
278
1000
2x0.75
0.5
1.0
6.5
59
1000
3x0.75
0.5
1.0
6.8
70
1000
4x0.75
0.5
1.0
7.4
83
1000
5x0.75
0.5
1.0
8.0
95
1000
6x0.75
0.5
1.1
8.8
112
1000
7x0.75
0.5
1.1
8.8
121
1000
8x0.75
0.5
1.1
10.1
138
1000
10x0.75
0.5
1.2
11.1
166
1000
12x0.75
0.5
1.2
11.5
187
1000
16x0.75
0.5
1.2
12.6
232
1000
20x0.75
0.5
1.3
14.1
284
1000
24x0.75
0.5
1.3
15.5
331
1000
30x0.75
0.5
1.4
16.6
401
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
15
KCI
RE-2X(St)Y
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.5
1.0
6.9
61
1000
3x1
0.5
1.0
7.2
75
1000
4x1
0.5
1.0
7.8
90
1000
5x1
0.5
1.1
8.7
109
1000
6x1
0.5
1.1
9.4
125
1000
7x1
0.5
1.1
9.4
138
1000
8x1
0.5
1.1
10.7
157
1000
10x1
0.5
1.2
11.8
192
1000
12x1
0.5
1.2
12.2
219
1000
16x1
0.5
1.2
13.5
275
1000
20x1
0.5
1.3
15.1
339
1000
24x1
0.5
1.3
16.6
398
1000
30x1
0.5
1.4
17.8
485
1000
Instrument Cables
16
2x1.5
0.6
1.0
7.9
78
1000
3x1.5
0.6
1.1
8.5
103
1000
4x1.5
0.6
1.1
9.2
125
1000
5x1.5
0.6
1.1
10.0
148
1000
6x1.5
0.6
1.1
10.9
171
1000
7x1.5
0.6
1.1
10.9
189
1000
8x1.5
0.6
1.2
12.7
223
1000
10x1.5
0.6
1.3
14.0
272
1000
12x1.5
0.6
1.3
14.5
312
1000
16x1.5
0.6
1.3
16.0
395
1000
20x1.5
0.6
1.4
18.0
488
1000
24x1.5
0.6
1.5
20.0
584
1000
30x1.5
0.6
1.5
21.2
702
1000
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.1
8.9
108
1000
3x2.5
0.6
1.1
9.4
138
1000
4x2.5
0.6
1.1
10.3
171
1000
5x2.5
0.6
1.2
11.4
209
1000
6x2.5
0.6
1.2
12.3
242
1000
7x2.5
0.6
1.2
12.3
270
1000
8x2.5
0.6
1.3
14.4
316
1000
10x2.5
0.6
1.3
15.7
380
1000
12x2.5
0.6
1.3
16.2
438
1000
16x2.5
0.6
1.4
18.2
569
1000
20x2.5
0.6
1.5
20.4
703
1000
24x2.5
0.6
1.6
22.7
840
1000
30x2.5
0.6
1.6
24.1
1017
1000
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
17
KCI
RE-2X(St)Y
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
18
Black,Blue (Numbered)
XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
1.0
5.7
49
1000
2x2x0.5
0.4
1.0
7.9
72
1000
3x2x0.5
0.4
1.1
8.5
91
1000
4x2x0.5
0.4
1.1
9.2
108
1000
5x2x0.5
0.4
1.1
10.0
125
1000
6x2x0.5
0.4
1.1
10.9
142
1000
7x2x0.5
0.4
1.1
10.9
155
1000
10x2x0.5
0.4
1.3
14.0
221
1000
12x2x0.5
0.4
1.3
14.5
249
1000
16x2x0.5
0.4
1.3
16.0
309
1000
20x2x0.5
0.4
1.4
17.9
379
1000
24x2x0.5
0.4
1.5
20.0
451
1000
30x2x0.5
0.4
1.5
21.2
535
1000
1x2x0.75
0.5
1.0
6.5
60
1000
2x2x0.75
0.5
1.1
9.4
97
1000
3x2x0.75
0.5
1.1
10.0
119
1000
4x2x0.75
0.5
1.1
10.9
143
1000
5x2x0.75
0.5
1.2
12.0
174
1000
6x2x0.75
0.5
1.2
13.1
199
1000
7x2x0.75
0.5
1.2
13.1
218
1000
10x2x0.75
0.5
1.4
16.9
312
1000
12x2x0.75
0.5
1.4
17.5
355
1000
16x2x0.75
0.5
1.5
19.6
453
1000
20x2x0.75
0.5
1.5
21.7
547
1000
24x2x0.75
0.5
1.6
24.3
652
1000
30x2x0.75
0.5
1.7
25.9
790
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
19
KCI
RE-2X(St)Y
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.5
1.0
6.9
61
1000
2x2x1
0.5
1.1
10.0
106
1000
3x2x1
0.5
1.1
10.6
134
1000
4x2x1
0.5
1.2
11.8
169
1000
5x2x1
0.5
1.2
12.8
201
1000
6x2x1
0.5
1.2
14.0
232
1000
7x2x1
0.5
1.2
14.0
257
1000
10x2x1
0.5
1.4
18.1
371
1000
12x2x1
0.5
1.4
18.7
424
1000
16x2x1
0.5
1.5
20.9
547
1000
20x2x1
0.5
1.6
23.5
675
1000
24x2x1
0.5
1.7
26.2
806
500
30x2x1
0.5
1.7
27.8
967
500
Instrument Cables
20
1x2x1.5
0.6
1.0
7.9
79
1000
2x2x1.5
0.6
1.2
11.8
145
1000
3x2x1.5
0.6
1.2
12.6
187
1000
4x2x1.5
0.6
1.2
13.8
232
1000
5x2x1.5
0.6
1.3
15.2
284
1000
6x2x1.5
0.6
1.3
16.6
330
1000
7x2x1.5
0.6
1.3
16.6
368
1000
10x2x1.5
0.6
1.5
21.6
529
1000
12x2x1.5
0.6
1.5
22.3
609
1000
16x2x1.5
0.6
1.6
25.0
789
500
20x2x1.5
0.6
1.7
28.1
974
500
24x2x1.5
0.6
1.9
31.5
1178
500
30x2x1.5
0.6
1.9
33.4
1420
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.1
8.9
109
1000
2x2x2.5
0.6
1.2
13.2
194
1000
3x2x2.5
0.6
1.3
14.3
262
1000
4x2x2.5
0.6
1.3
15.6
328
1000
5x2x2.5
0.6
1.4
17.3
402
1000
6x2x2.5
0.6
1.4
18.9
469
1000
7x2x2.5
0.6
1.4
18.9
526
1000
10x2x2.5
0.6
1.6
24.5
755
500
12x2x2.5
0.6
1.7
25.6
886
500
16x2x2.5
0.6
1.8
28.6
1149
500
20x2x2.5
0.6
1.9
32.1
1419
500
24x2x2.5
0.6
2.0
35.9
1694
500
30x2x2.5
0.6
2.1
38.2
2072
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
21
KCI
RE-2X(St)Y
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
Instrument Cables
Criteria
22
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
1.0
6.0
56
1000
2x3x0.5
0.4
1.1
8.8
93
1000
3x3x0.5
0.4
1.1
9.3
115
1000
4x3x0.5
0.4
1.1
10.2
138
1000
5x3x0.5
0.4
1.2
11.3
167
1000
6x3x0.5
0.4
1.2
12.2
192
1000
7x3x0.5
0.4
1.2
12.2
211
1000
10x3x0.5
0.4
1.3
15.6
294
1000
12x3x0.5
0.4
1.3
16.1
335
1000
16x3x0.5
0.4
1.4
18.0
430
1000
20x3x0.5
0.4
1.5
20.2
528
1000
24x3x0.5
0.4
1.6
22.5
630
1000
30x3x0.5
0.4
1.6
23.8
753
1000
1x3x0.75
0.5
1.0
6.8
71
1000
2x3x0.75
0.5
1.1
10.4
122
1000
3x3x0.75
0.5
1.2
11.2
159
1000
4x3x0.75
0.5
1.2
12.2
194
1000
5x3x0.75
0.5
1.2
13.3
230
1000
6x3x0.75
0.5
1.3
14.7
272
1000
7x3x0.75
0.5
1.3
14.7
301
1000
10x3x0.75
0.5
1.4
18.9
422
1000
12x3x0.75
0.5
1.5
19.7
493
1000
16x3x0.75
0.5
1.5
21.8
624
1000
20x3x0.75
0.5
1.6
24.5
769
500
24x3x0.75
0.5
1.7
27.3
918
500
30x3x0.75
0.5
1.8
29.2
1118
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
23
KCI
RE-2X(St)Y
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.5
1.0
7.2
76
1000
2x3x1
0.5
1.1
11.0
136
1000
3x3x1
0.5
1.2
11.9
183
1000
4x3x1
0.5
1.2
13.0
227
1000
5x3x1
0.5
1.3
14.4
278
1000
6x3x1
0.5
1.3
15.7
323
1000
7x3x1
0.5
1.3
15.7
360
1000
10x3x1
0.5
1.5
20.4
518
1000
12x3x1
0.5
1.5
21.1
598
1000
16x3x1
0.5
1.6
23.6
775
1000
20x3x1
0.5
1.7
26.5
957
500
24x3x1
0.5
1.8
29.6
1143
500
30x3x1
0.5
1.8
31.3
1382
500
Instrument Cables
24
1x3x1.5
0.6
1.0
8.3
100
1000
2x3x1.5
0.6
1.2
13.1
190
1000
3x3x1.5
0.6
1.2
13.9
252
1000
4x3x1.5
0.6
1.3
15.5
323
1000
5x3x1.5
0.6
1.4
17.2
396
1000
6x3x1.5
0.6
1.4
18.7
463
1000
7x3x1.5
0.6
1.4
18.7
520
1000
10x3x1.5
0.6
1.6
24.3
746
1000
12x3x1.5
0.6
1.6
25.2
865
500
16x3x1.5
0.6
1.7
28.2
1125
500
20x3x1.5
0.6
1.9
31.9
1405
500
24x3x1.5
0.6
2.0
35.6
1679
500
30x3x1.5
0.6
2.1
37.9
2053
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.1
9.4
140
1000
2x3x2.5
0.6
1.3
14.9
267
1000
3x3x2.5
0.6
1.3
15.8
358
1000
4x3x2.5
0.6
1.4
17.6
461
1000
5x3x2.5
0.6
1.4
19.3
557
1000
6x3x2.5
0.6
1.5
21.3
664
1000
7x3x2.5
0.6
1.5
21.3
749
1000
10x3x2.5
0.6
1.7
27.7
1073
500
12x3x2.5
0.6
1.8
28.8
1264
500
16x3x2.5
0.6
1.9
32.3
1646
500
20x3x2.5
0.6
2.0
36.3
2037
500
24x3x2.5
0.6
2.2
40.7
2452
500
30x3x2.5
0.6
2.3
43.3
3007
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
25
KCI
RE-2X(St)Y , PiMF
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
26
Black,Blue (Numbered)
XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
1.0
6.0
66
1000
2x2x0.5
0.4
1.1
9.2
113
1000
3x2x0.5
0.4
1.1
9.7
145
1000
4x2x0.5
0.4
1.1
10.6
178
1000
5x2x0.5
0.4
1.2
11.7
216
1000
6x2x0.5
0.4
1.2
12.7
251
1000
7x2x0.5
0.4
1.2
12.7
279
1000
10x2x0.5
0.4
1.3
16.3
391
1000
12x2x0.5
0.4
1.4
17.0
458
1000
16x2x0.5
0.4
1.4
18.8
584
1000
20x2x0.5
0.4
1.5
21.1
720
1000
24x2x0.5
0.4
1.6
23.5
860
1000
30x2x0.5
0.4
1.6
24.9
1040
500
1x2x0.75
0.5
1.0
6.9
78
1000
2x2x0.75
0.5
1.1
10.6
136
1000
3x2x0.75
0.5
1.2
11.5
181
1000
4x2x0.75
0.5
1.2
12.5
222
1000
5x2x0.75
0.5
1.2
13.7
265
1000
6x2x0.75
0.5
1.3
15.1
314
1000
7x2x0.75
0.5
1.3
15.1
350
1000
10x2x0.75
0.5
1.4
19.4
492
1000
12x2x0.75
0.5
1.5
20.2
576
1000
16x2x0.75
0.5
1.6
22.6
745
1000
20x2x0.75
0.5
1.7
25.4
918
500
24x2x0.75
0.5
1.8
28.3
1096
500
30x2x0.75
0.5
1.8
30.0
1323
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
27
KCI
RE-2X(St)Y , PiMF
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.5
1.0
7.2
74
1000
2x2x1
0.5
1.1
11.3
134
1000
3x2x1
0.5
1.2
12.2
179
1000
4x2x1
0.5
1.2
13.3
222
1000
5x2x1
0.5
1.3
14.7
271
1000
6x2x1
0.5
1.3
16.1
316
1000
7x2x1
0.5
1.3
16.1
351
1000
10x2x1
0.5
1.5
20.9
505
1000
12x2x1
0.5
1.5
21.6
582
1000
16x2x1
0.5
1.6
24.1
753
1000
20x2x1
0.5
1.7
27.1
929
500
24x2x1
0.5
1.8
30.2
1110
500
30x2x1
0.5
1.9
32.2
1354
500
Instrument Cables
28
1x2x1.5
0.6
1.0
8.2
92
1000
2x2x1.5
0.6
1.2
13.2
177
1000
3x2x1.5
0.6
1.3
14.3
238
1000
4x2x1.5
0.6
1.3
15.7
295
1000
5x2x1.5
0.6
1.4
17.3
362
1000
6x2x1.5
0.6
1.4
18.9
422
1000
7x2x1.5
0.6
1.4
18.9
471
1000
10x2x1.5
0.6
1.6
24.6
677
500
12x2x1.5
0.6
1.6
25.5
782
500
16x2x1.5
0.6
1.8
28.7
1026
500
20x2x1.5
0.6
1.9
32.2
1266
500
24x2x1.5
0.6
2.0
36.0
1511
500
30x2x1.5
0.6
2.1
38.3
1843
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.1
9.3
126
1000
2x2x2.5
0.6
1.3
14.9
240
1000
3x2x2.5
0.6
1.3
15.9
317
1000
4x2x2.5
0.6
1.4
17.7
407
1000
5x2x2.5
0.6
1.4
19.4
490
1000
6x2x2.5
0.6
1.5
21.4
583
1000
7x2x2.5
0.6
1.5
21.4
654
1000
10x2x2.5
0.6
1.7
27.8
938
500
12x2x2.5
0.6
1.8
29.0
1102
500
16x2x2.5
0.6
1.9
32.4
1430
500
20x2x2.5
0.6
2.0
36.4
1767
500
24x2x2.5
0.6
2.2
40.9
2128
500
30x2x2.5
0.6
2.3
43.5
2601
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
29
KCI
RE-2X(St)Y , TiMF
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+90 oC
Instrument Cables
30
XLPE
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
1.0
6.3
74
1000
2x3x0.5
0.4
1.1
10.1
131
1000
3x3x0.5
0.4
1.1
10.7
169
1000
4x3x0.5
0.4
1.2
11.9
215
1000
5x3x0.5
0.4
1.2
12.9
256
1000
6x3x0.5
0.4
1.3
14.2
304
1000
7x3x0.5
0.4
1.3
14.2
339
1000
10x3x0.5
0.4
1.4
18.2
476
1000
12x3x0.5
0.4
1.4
18.8
549
1000
16x3x0.5
0.4
1.5
21.1
712
1000
20x3x0.5
0.4
1.6
23.7
879
1000
24x3x0.5
0.4
1.7
26.4
1050
500
30x3x0.5
0.4
1.7
28.0
1271
500
1x3x0.75
0.5
1.0
7.2
89
1000
2x3x0.75
0.5
1.2
11.9
167
1000
3x3x0.75
0.5
1.2
12.7
217
1000
4x3x0.75
0.5
1.2
13.9
270
1000
5x3x0.75
0.5
1.3
15.4
330
1000
6x3x0.75
0.5
1.4
16.9
392
1000
7x3x0.75
0.5
1.4
16.9
437
1000
10x3x0.75
0.5
1.5
21.8
616
1000
12x3x0.75
0.5
1.6
22.7
722
1000
16x3x0.75
0.5
1.7
25.4
935
500
20x3x0.75
0.5
1.8
28.5
1153
500
24x3x0.75
0.5
1.9
31.8
1377
500
30x3x0.75
0.5
2.0
33.9
1682
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
31
KCI
RE-2X(St)Y , TiMF
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.5
1.0
7.6
88
1000
2x3x1
0.5
1.2
12.7
172
1000
3x3x1
0.5
1.2
13.5
225
1000
4x3x1
0.5
1.3
14.9
288
1000
5x3x1
0.5
1.3
16.3
345
1000
6x3x1
0.5
1.4
18.0
412
1000
7x3x1
0.5
1.4
18.0
460
1000
10x3x1
0.5
1.6
23.4
661
1000
12x3x1
0.5
1.6
24.2
763
1000
16x3x1
0.5
1.7
27.1
990
500
20x3x1
0.5
1.8
30.4
1223
500
24x3x1
0.5
1.9
34.0
1461
500
30x3x1
0.5
2.0
36.2
1786
500
Instrument Cables
32
1x3x1.5
0.6
1.1
8.9
118
1000
2x3x1.5
0.6
1.3
14.9
231
1000
3x3x1.5
0.6
1.3
15.8
305
1000
4x3x1.5
0.6
1.4
17.6
391
1000
5x3x1.5
0.6
1.4
19.3
471
1000
6x3x1.5
0.6
1.5
21.3
561
1000
7x3x1.5
0.6
1.5
21.3
629
1000
10x3x1.5
0.6
1.7
27.7
903
500
12x3x1.5
0.6
1.8
28.8
1060
500
16x3x1.5
0.6
1.9
32.3
1375
500
20x3x1.5
0.6
2.0
36.3
1699
500
24x3x1.5
0.6
2.2
40.7
2047
500
30x3x1.5
0.6
2.3
43.3
2502
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.1
9.8
157
1000
2x3x2.5
0.6
1.3
16.6
308
1000
3x3x2.5
0.6
1.4
17.9
423
1000
4x3x2.5
0.6
1.4
19.7
535
1000
5x3x2.5
0.6
1.5
21.8
658
1000
6x3x2.5
0.6
1.6
24.0
785
1000
7x3x2.5
0.6
1.6
24.0
884
1000
10x3x2.5
0.6
1.9
31.5
1281
500
12x3x2.5
0.6
1.9
32.6
1491
500
16x3x2.5
0.6
2.0
36.5
1941
500
20x3x2.5
0.6
2.2
41.2
2420
500
24x3x2.5
0.6
2.4
46.2
2911
500
30x3x2.5
0.6
2.5
49.2
3565
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
33
KCI
RE-YCY
IEC 60092-376
150/250 V (300 V)
RE-YCY Multi-Core
RE-YCY Multi-Pair
RE-YCY Multi-Triple
RE-YCY PiMF
RE-YCY TiMF
RE-2XCH
RE-2XCH Multi-Core
RE-2XCH Multi-Pair
RE-2XCH Multi-Triple
RE-2XCH PiMF
RE-2XCH TiMF
KCI
RE-YCY
150/250 V (300 V)
IEC 60092-376
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+70 oC
Instrument Cables
36
PVC
Core (Multi-Core Cable)
Braid of Copper Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.0
7.0
65
1000
3x0.5
0.6
1.0
7.4
76
1000
4x0.5
0.6
1.0
7.9
91
1000
5x0.5
0.6
1.1
8.7
110
1000
6x0.5
0.6
1.1
9.3
123
1000
7x0.5
0.6
1.1
9.3
131
1000
8x0.5
0.6
1.1
10.6
151
1000
10x0.5
0.6
1.2
11.6
178
1000
12x0.5
0.6
1.2
12.0
198
1000
16x0.5
0.6
1.2
13.3
266
1000
20x0.5
0.6
1.3
14.8
324
1000
24x0.5
0.6
1.4
16.4
377
1000
30x0.5
0.6
1.4
17.3
443
1000
2x0.75
0.6
1.0
7.4
73
1000
3x0.75
0.6
1.0
7.8
91
1000
4x0.75
0.6
1.1
8.6
109
1000
5x0.75
0.6
1.1
9.3
129
1000
6x0.75
0.6
1.1
9.9
148
1000
7x0.75
0.6
1.1
9.9
160
1000
8x0.75
0.6
1.2
11.5
185
1000
10x0.75
0.6
1.2
12.7
233
1000
12x0.75
0.6
1.2
13.1
266
1000
16x0.75
0.6
1.3
14.5
328
1000
20x0.75
0.6
1.3
16.0
392
1000
24x0.75
0.6
1.4
17.7
466
1000
30x0.75
0.6
1.4
18.9
577
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
37
KCI
RE-YCY
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.6
1.0
7.8
85
1000
3x1
0.6
1.0
8.2
102
1000
4x1
0.6
1.1
9.0
128
1000
5x1
0.6
1.1
9.7
146
1000
6x1
0.6
1.1
10.5
169
1000
7x1
0.6
1.1
10.5
184
1000
8x1
0.6
1.2
12.4
231
1000
10x1
0.6
1.2
13.4
274
1000
12x1
0.6
1.2
13.8
307
1000
16x1
0.6
1.3
15.3
389
1000
20x1
0.6
1.4
17.1
474
1000
24x1
0.6
1.4
19.0
580
1000
30x1
0.6
1.5
20.2
686
1000
Instrument Cables
38
2x1.5
0.7
1.1
9.0
112
1000
3x1.5
0.7
1.1
9.5
137
1000
4x1.5
0.7
1.1
10.3
167
1000
5x1.5
0.7
1.2
11.3
198
1000
6x1.5
0.7
1.2
12.4
245
1000
7x1.5
0.7
1.2
12.4
267
1000
8x1.5
0.7
1.3
14.4
314
1000
10x1.5
0.7
1.3
15.6
373
1000
12x1.5
0.7
1.3
16.1
420
1000
16x1.5
0.7
1.4
17.9
535
1000
20x1.5
0.7
1.5
20.2
681
1000
24x1.5
0.7
1.6
22.4
809
1000
30x1.5
0.7
1.6
23.6
953
1000
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.7
1.1
9.8
141
1000
3x2.5
0.7
1.1
10.4
176
1000
4x2.5
0.7
1.2
11.5
218
1000
5x2.5
0.7
1.2
12.7
275
1000
6x2.5
0.7
1.2
13.7
320
1000
7x2.5
0.7
1.2
13.7
352
1000
8x2.5
0.7
1.3
15.9
412
1000
10x2.5
0.7
1.4
17.5
502
1000
12x2.5
0.7
1.4
18.0
570
1000
16x2.5
0.7
1.5
20.3
755
1000
20x2.5
0.7
1.6
22.6
926
1000
24x2.5
0.7
1.6
24.9
1084
500
30x2.5
0.7
1.7
26.5
1303
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
39
KCI
RE-YCY
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+70 oC
Instrument Cables
40
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
PVC
Pair (Multi-Pair Cable)
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.0
7.0
66
1000
2x2x0.5
0.6
1.1
9.9
113
1000
3x2x0.5
0.6
1.1
10.5
134
1000
4x2x0.5
0.6
1.2
11.6
162
1000
5x2x0.5
0.6
1.2
12.7
205
1000
6x2x0.5
0.6
1.3
14.0
243
1000
7x2x0.5
0.6
1.3
14.0
261
1000
10x2x0.5
0.6
1.4
17.6
362
1000
12x2x0.5
0.6
1.4
18.2
402
1000
16x2x0.5
0.6
1.5
20.5
531
1000
20x2x0.5
0.6
1.6
22.8
646
1000
24x2x0.5
0.6
1.7
25.3
760
500
30x2x0.5
0.6
1.7
26.7
883
500
1x2x0.75
0.6
1.0
7.4
74
1000
2x2x0.75
0.6
1.1
10.6
129
1000
3x2x0.75
0.6
1.2
11.4
162
1000
4x2x0.75
0.6
1.2
12.6
211
1000
5x2x0.75
0.6
1.2
13.7
249
1000
6x2x0.75
0.6
1.3
15.0
294
1000
7x2x0.75
0.6
1.3
15.0
318
1000
10x2x0.75
0.6
1.4
19.2
467
1000
12x2x0.75
0.6
1.5
20.0
530
1000
16x2x0.75
0.6
1.5
22.1
657
1000
20x2x0.75
0.6
1.6
24.7
795
500
24x2x0.75
0.6
1.7
27.4
944
500
30x2x0.75
0.6
1.8
29.2
1120
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
41
KCI
RE-YCY
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.6
1.0
7.8
86
1000
2x2x1
0.6
1.1
11.2
145
1000
3x2x1
0.6
1.2
12.3
203
1000
4x2x1
0.6
1.2
13.3
247
1000
5x2x1
0.6
1.3
14.7
298
1000
6x2x1
0.6
1.3
15.9
337
1000
7x2x1
0.6
1.3
15.9
367
1000
10x2x1
0.6
1.5
20.6
548
1000
12x2x1
0.6
1.5
21.3
614
1000
16x2x1
0.6
1.6
23.7
779
1000
20x2x1
0.6
1.7
26.4
946
500
24x2x1
0.6
1.8
29.4
1125
500
30x2x1
0.6
1.8
31.0
1327
500
Instrument Cables
42
1x2x1.5
0.7
1.1
9.0
113
1000
2x2x1.5
0.7
1.2
13.3
215
1000
3x2x1.5
0.7
1.3
14.2
271
1000
4x2x1.5
0.7
1.3
15.5
332
1000
5x2x1.5
0.7
1.4
17.1
402
1000
6x2x1.5
0.7
1.4
18.6
458
1000
7x2x1.5
0.7
1.4
18.6
503
1000
10x2x1.5
0.7
1.6
24.1
748
1000
12x2x1.5
0.7
1.6
24.9
852
500
16x2x1.5
0.7
1.7
27.7
1086
500
20x2x1.5
0.7
1.9
31.2
1330
500
24x2x1.5
0.7
2.0
34.7
1597
500
30x2x1.5
0.7
2.1
36.9
1900
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.7
1.1
9.8
142
1000
2x2x2.5
0.7
1.3
14.8
280
1000
3x2x2.5
0.7
1.3
15.7
351
1000
4x2x2.5
0.7
1.4
17.4
442
1000
5x2x2.5
0.7
1.4
19.2
553
1000
6x2x2.5
0.7
1.5
21.0
642
1000
7x2x2.5
0.7
1.5
21.0
707
1000
10x2x2.5
0.7
1.7
27.0
1003
500
12x2x2.5
0.7
1.7
27.9
1157
500
16x2x2.5
0.7
1.9
31.4
1483
500
20x2x2.5
0.7
2.0
35.1
1828
500
24x2x2.5
0.7
2.1
39.0
2154
500
30x2x2.5
0.7
2.2
41.5
2595
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
43
KCI
RE-YCY
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Braid of Copper Wires
Screen
Outer Sheath
Extruded PVC
+70 oC
IEC 60332-1
Instrument Cables
Criteria
44
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.0
7.4
76
1000
2x3x0.5
0.6
1.1
10.9
136
1000
3x3x0.5
0.6
1.2
11.7
172
1000
4x3x0.5
0.6
1.2
12.9
231
1000
5x3x0.5
0.6
1.3
14.2
271
1000
6x3x0.5
0.6
1.3
15.4
314
1000
7x3x0.5
0.6
1.3
15.4
341
1000
10x3x0.5
0.6
1.5
20.0
509
1000
12x3x0.5
0.6
1.5
20.6
568
1000
16x3x0.5
0.6
1.6
22.9
718
1000
20x3x0.5
0.6
1.7
25.6
869
500
24x3x0.5
0.6
1.8
28.4
1033
500
30x3x0.5
0.6
1.8
30.0
1214
500
1x3x0.75
0.6
1.0
7.8
91
1000
2x3x0.75
0.6
1.2
11.9
164
1000
3x3x0.75
0.6
1.2
12.8
224
1000
4x3x0.75
0.6
1.3
14.1
281
1000
5x3x0.75
0.6
1.3
15.3
332
1000
6x3x0.75
0.6
1.4
16.8
393
1000
7x3x0.75
0.6
1.4
16.8
429
1000
10x3x0.75
0.6
1.5
21.5
628
1000
12x3x0.75
0.6
1.6
22.4
717
1000
16x3x0.75
0.6
1.6
24.8
891
500
20x3x0.75
0.6
1.8
27.9
1104
500
24x3x0.75
0.6
1.9
31.0
1298
500
30x3x0.75
0.6
1.9
32.7
1538
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
45
KCI
RE-YCY
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.6
1.0
8.2
103
1000
2x3x1
0.6
1.2
12.7
206
1000
3x3x1
0.6
1.2
13.5
263
1000
4x3x1
0.6
1.3
14.9
330
1000
5x3x1
0.6
1.3
16.2
385
1000
6x3x1
0.6
1.4
17.8
456
1000
7x3x1
0.6
1.4
17.8
501
1000
10x3x1
0.6
1.6
23.1
743
1000
12x3x1
0.6
1.6
23.8
840
1000
16x3x1
0.6
1.7
26.5
1067
500
20x3x1
0.6
1.8
29.7
1309
500
24x3x1
0.6
1.9
33.0
1545
500
30x3x1
0.6
2.0
35.1
1878
500
Instrument Cables
46
1x3x1.5
0.7
1.1
9.5
138
1000
2x3x1.5
0.7
1.3
14.8
283
1000
3x3x1.5
0.7
1.3
15.7
356
1000
4x3x1.5
0.7
1.4
17.4
449
1000
5x3x1.5
0.7
1.4
19.2
561
1000
6x3x1.5
0.7
1.5
21.0
652
1000
7x3x1.5
0.7
1.5
21.0
719
1000
10x3x1.5
0.7
1.7
27.0
1019
500
12x3x1.5
0.7
1.7
27.9
1177
500
16x3x1.5
0.7
1.9
31.3
1510
500
20x3x1.5
0.7
2.0
35.0
1862
500
24x3x1.5
0.7
2.1
39.0
2195
500
30x3x1.5
0.7
2.2
41.5
2646
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.7
1.1
10.4
178
1000
2x3x2.5
0.7
1.3
16.4
363
1000
3x3x2.5
0.7
1.4
17.6
477
1000
4x3x2.5
0.7
1.4
19.5
621
1000
5x3x2.5
0.7
1.5
21.5
756
1000
6x3x2.5
0.7
1.6
23.6
883
1000
7x3x2.5
0.7
1.6
23.6
980
1000
10x3x2.5
0.7
1.8
30.4
1393
500
12x3x2.5
0.7
1.9
31.6
1616
500
16x3x2.5
0.7
2.0
35.2
2090
500
20x3x2.5
0.7
2.1
39.4
2550
500
24x3x2.5
0.7
2.3
44.1
3055
500
30x3x2.5
0.7
2.4
46.9
3702
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
47
KCI
RE-YCY , PiMF
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+70 oC
Instrument Cables
48
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.0
7.4
84
1000
2x2x0.5
0.6
1.2
11.3
157
1000
3x2x0.5
0.6
1.2
12.2
214
1000
4x2x0.5
0.6
1.2
13.3
262
1000
5x2x0.5
0.6
1.3
14.6
310
1000
6x2x0.5
0.6
1.3
15.8
361
1000
7x2x0.5
0.6
1.3
15.8
395
1000
10x2x0.5
0.6
1.5
20.5
587
1000
12x2x0.5
0.6
1.5
21.1
661
1000
16x2x0.5
0.6
1.6
23.5
841
1000
20x2x0.5
0.6
1.7
26.3
1023
500
24x2x0.5
0.6
1.8
29.2
1219
500
30x2x0.5
0.6
1.9
31.1
1458
500
1x2x0.75
0.6
1.0
7.8
96
1000
2x2x0.75
0.6
1.2
12.3
194
1000
3x2x0.75
0.6
1.2
13.0
246
1000
4x2x0.75
0.6
1.3
14.4
301
1000
5x2x0.75
0.6
1.3
15.6
357
1000
6x2x0.75
0.6
1.4
17.1
423
1000
7x2x0.75
0.6
1.4
17.1
463
1000
10x2x0.75
0.6
1.5
22.0
678
1000
12x2x0.75
0.6
1.6
22.9
776
1000
16x2x0.75
0.6
1.7
25.5
982
500
20x2x0.75
0.6
1.8
28.5
1203
500
24x2x0.75
0.6
1.9
31.6
1417
500
30x2x0.75
0.6
2.0
33.6
1700
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
49
KCI
RE-YCY , PiMF
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.6
1.0
8.2
98
1000
2x2x1
0.6
1.2
12.9
206
1000
3x2x1
0.6
1.2
13.7
253
1000
4x2x1
0.6
1.3
15.1
316
1000
5x2x1
0.6
1.3
16.5
374
1000
6x2x1
0.6
1.4
18.1
434
1000
7x2x1
0.6
1.4
18.1
475
1000
10x2x1
0.6
1.6
23.5
707
1000
12x2x1
0.6
1.6
24.2
797
1000
16x2x1
0.6
1.7
27.0
1009
500
20x2x1
0.6
1.8
30.2
1237
500
24x2x1
0.6
1.9
33.6
1458
500
30x2x1
0.6
2.0
35.7
1768
500
Instrument Cables
50
1x2x1.5
0.7
1.1
9.4
127
1000
2x2x1.5
0.7
1.3
14.9
263
1000
3x2x1.5
0.7
1.3
15.8
326
1000
4x2x1.5
0.7
1.4
17.5
408
1000
5x2x1.5
0.7
1.4
19.3
511
1000
6x2x1.5
0.7
1.5
21.2
591
1000
7x2x1.5
0.7
1.5
21.2
648
1000
10x2x1.5
0.7
1.7
27.2
918
500
12x2x1.5
0.7
1.7
28.1
1055
500
16x2x1.5
0.7
1.9
31.6
1347
500
20x2x1.5
0.7
2.0
35.3
1657
500
24x2x1.5
0.7
2.1
39.3
1950
500
30x2x1.5
0.7
2.2
41.8
2354
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.7
1.1
10.2
159
1000
2x2x2.5
0.7
1.3
16.4
328
1000
3x2x2.5
0.7
1.4
17.6
424
1000
4x2x2.5
0.7
1.4
19.5
551
1000
5x2x2.5
0.7
1.5
21.5
669
1000
6x2x2.5
0.7
1.6
23.6
778
1000
7x2x2.5
0.7
1.6
23.6
858
1000
10x2x2.5
0.7
1.8
30.4
1218
500
12x2x2.5
0.7
1.9
31.6
1406
500
16x2x2.5
0.7
2.0
35.3
1810
500
20x2x2.5
0.7
2.1
39.5
2200
500
24x2x2.5
0.7
2.3
44.2
2635
500
30x2x2.5
0.7
2.4
47.0
3177
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
51
KCI
RE-YCY , TiMF
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+70 oC
Instrument Cables
52
PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Braid of Copper Wires
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
1.0
7.7
98
1000
2x3x0.5
0.6
1.2
12.6
202
1000
3x3x0.5
0.6
1.2
13.4
257
1000
4x3x0.5
0.6
1.3
14.8
322
1000
5x3x0.5
0.6
1.3
16.1
374
1000
6x3x0.5
0.6
1.4
17.6
443
1000
7x3x0.5
0.6
1.4
17.6
486
1000
10x3x0.5
0.6
1.6
22.9
722
1000
12x3x0.5
0.6
1.6
23.6
816
1000
16x3x0.5
0.6
1.7
26.3
1034
500
20x3x0.5
0.6
1.8
29.4
1268
500
24x3x0.5
0.6
1.9
32.7
1496
500
30x3x0.5
0.6
2.0
34.7
1824
500
1x3x0.75
0.6
1.0
8.2
110
1000
2x3x0.75
0.6
1.2
13.5
233
1000
3x3x0.75
0.6
1.3
14.5
298
1000
4x3x0.75
0.6
1.3
15.8
367
1000
5x3x0.75
0.6
1.4
17.4
446
1000
6x3x0.75
0.6
1.4
19.1
544
1000
7x3x0.75
0.6
1.4
19.1
597
1000
10x3x0.75
0.6
1.6
24.6
835
500
12x3x0.75
0.6
1.7
25.6
968
500
16x3x0.75
0.6
1.8
28.5
1237
500
20x3x0.75
0.6
1.9
31.8
1503
500
24x3x0.75
0.6
2.0
35.4
1797
500
30x3x0.75
0.6
2.1
37.7
2157
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
53
KCI
RE-YCY , TiMF
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
Kg/Km
meter
0.6
1.1
8.8
124
1000
2x3x1
0.6
1.3
14.4
252
1000
3x3x1
0.6
1.3
15.3
322
1000
4x3x1
0.6
1.3
16.7
396
1000
5x3x1
0.6
1.4
18.4
472
1000
6x3x1
0.6
1.5
20.4
585
1000
7x3x1
0.6
1.5
20.4
641
1000
10x3x1
0.6
1.7
26.2
907
500
12x3x1
0.6
1.7
27.1
1030
500
16x3x1
0.6
1.8
30.2
1318
500
20x3x1
0.6
1.9
33.8
1631
500
24x3x1
0.6
2.1
37.8
1931
500
30x3x1
0.6
2.1
40.0
2299
500
Instrument Cables
54
1x3x1.5
0.7
1.1
9.8
156
1000
2x3x1.5
0.7
1.3
16.4
327
1000
3x3x1.5
0.7
1.4
17.7
421
1000
4x3x1.5
0.7
1.4
19.6
547
1000
5x3x1.5
0.7
1.5
21.6
664
1000
6x3x1.5
0.7
1.6
23.7
773
1000
7x3x1.5
0.7
1.6
23.7
852
1000
10x3x1.5
0.7
1.8
30.5
1209
500
12x3x1.5
0.7
1.9
31.7
1395
500
16x3x1.5
0.7
2.0
35.4
1795
500
20x3x1.5
0.7
2.1
39.6
2181
500
24x3x1.5
0.7
2.3
44.3
2613
500
30x3x1.5
0.7
2.4
47.1
3149
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-YCY , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.7
1.1
10.7
195
1000
2x3x2.5
0.7
1.4
18.4
416
1000
3x3x2.5
0.7
1.4
19.7
572
1000
4x3x2.5
0.7
1.5
21.8
724
1000
5x3x2.5
0.7
1.6
24.1
867
1000
6x3x2.5
0.7
1.7
26.4
1023
500
7x3x2.5
0.7
1.7
26.4
1136
500
10x3x2.5
0.7
2.0
34.3
1652
500
12x3x2.5
0.7
2.0
35.4
1887
500
16x3x2.5
0.7
2.1
39.6
2408
500
20x3x2.5
0.7
2.3
44.5
2980
500
24x3x2.5
0.7
2.5
49.8
3577
500
30x3x2.5
0.7
2.6
53.0
4331
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
55
KCI
RE-2X(St)YQY
IEC 60092-376
150/250 V (300 V)
RE-2X(St)YQY Multi-Core
RE-2X(St)YQY Multi-Pair
RE-2X(St)YQY Multi-Triple
RE-2X(St)YQY PiMF
RE-2X(St)YQY TiMF
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-2X(St)QY
150/250 V (300 V)
IEC 60092-376
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
Instrument Cables
58
XLPE
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)QY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
0.2
5.7
1.1
8.8
117
1000
3x0.5
0.4
0.2
6.0
1.1
9.1
126
1000
4x0.5
0.4
0.2
6.4
1.1
9.5
137
1000
5x0.5
0.4
0.2
6.9
1.1
10.0
148
1000
6x0.5
0.4
0.2
7.4
1.1
10.5
166
1000
7x0.5
0.4
0.2
7.4
1.1
10.5
172
1000
8x0.5
0.4
0.2
8.4
1.2
11.7
201
1000
10x0.5
0.4
0.2
9.1
1.2
12.4
221
1000
12x0.5
0.4
0.2
9.4
1.2
12.7
236
1000
16x0.5
0.4
0.2
10.3
1.3
13.8
284
1000
20x0.5
0.4
0.3
11.3
1.3
15.3
359
1000
24x0.5
0.4
0.3
12.5
1.4
16.6
405
1000
30x0.5
0.4
0.3
13.2
1.4
17.3
451
1000
2x0.75
0.5
0.2
6.5
1.1
9.6
132
1000
3x0.75
0.5
0.2
6.8
1.1
9.9
145
1000
4x0.75
0.5
0.2
7.4
1.1
10.5
167
1000
5x0.75
0.5
0.2
8.0
1.2
11.3
188
1000
6x0.75
0.5
0.2
8.6
1.2
11.9
210
1000
7x0.75
0.5
0.2
8.6
1.2
11.9
220
1000
8x0.75
0.5
0.2
9.9
1.2
13.2
243
1000
10x0.75
0.5
0.3
10.7
1.3
14.7
308
1000
12x0.75
0.5
0.3
11.1
1.3
15.0
345
1000
16x0.75
0.5
0.3
12.2
1.4
16.4
404
1000
20x0.75
0.5
0.3
13.5
1.4
17.7
459
1000
24x0.75
0.5
0.3
14.9
1.5
19.3
534
1000
30x0.75
0.5
0.3
15.8
1.5
20.2
621
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
59
KCI
RE-2X(St)YQY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
mm
Kg/Km
meter
0.5
0.2
6.9
1.1
10.0
136
1000
3x1
0.5
0.2
7.2
1.1
10.3
158
1000
4x1
0.5
0.2
7.8
1.2
11.1
182
1000
5x1
0.5
0.2
8.5
1.2
11.8
207
1000
6x1
0.5
0.2
9.2
1.2
12.5
227
1000
7x1
0.5
0.2
9.2
1.2
12.5
239
1000
8x1
0.5
0.3
10.5
1.3
14.5
303
1000
10x1
0.5
0.3
11.4
1.3
15.4
353
1000
12x1
0.5
0.3
11.8
1.3
15.8
381
1000
16x1
0.5
0.3
13.1
1.4
17.2
453
1000
20x1
0.5
0.3
14.5
1.4
18.6
536
1000
24x1
0.5
0.3
16.0
1.5
20.4
627
1000
30x1
0.5
0.3
17.0
1.5
21.3
712
1000
Instrument Cables
60
2x1.5
0.6
0.2
7.9
1.2
11.2
170
1000
3x1.5
0.6
0.2
8.3
1.2
11.6
193
1000
4x1.5
0.6
0.2
9.0
1.2
12.3
226
1000
5x1.5
0.6
0.2
9.8
1.2
13.1
253
1000
6x1.5
0.6
0.3
10.7
1.3
14.6
317
1000
7x1.5
0.6
0.3
10.7
1.3
14.6
335
1000
8x1.5
0.6
0.3
12.3
1.3
16.3
389
1000
10x1.5
0.6
0.3
13.4
1.4
17.6
447
1000
12x1.5
0.6
0.3
13.9
1.4
18.0
505
1000
16x1.5
0.6
0.3
15.4
1.5
19.8
621
1000
20x1.5
0.6
0.3
17.2
1.5
21.5
716
1000
24x1.5
0.6
0.3
19.0
1.6
23.6
844
1000
30x1.5
0.6
0.3
20.2
1.7
24.9
980
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
0.2
8.7
1.2
12.0
207
1000
3x2.5
0.6
0.2
9.2
1.2
12.5
240
1000
4x2.5
0.6
0.2
10.1
1.2
13.4
284
1000
5x2.5
0.6
0.3
11.0
1.3
14.9
366
1000
6x2.5
0.6
0.3
11.9
1.3
15.9
406
1000
7x2.5
0.6
0.3
11.9
1.3
15.9
433
1000
8x2.5
0.6
0.3
13.8
1.4
18.0
508
1000
10x2.5
0.6
0.3
15.1
1.5
19.5
583
1000
12x2.5
0.6
0.3
15.6
1.5
20.0
665
1000
16x2.5
0.6
0.3
17.4
1.5
21.7
798
1000
20x2.5
0.6
0.3
19.4
1.6
23.9
965
1000
24x2.5
0.6
0.3
21.5
1.7
26.3
1116
500
30x2.5
0.6
0.3
22.9
1.8
27.8
1333
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
61
KCI
RE-2X(St)YQY
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
Instrument Cables
62
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
0.2
5.7
1.1
8.8
118
1000
2x2x0.5
0.4
0.2
7.9
1.2
11.2
164
1000
3x2x0.5
0.4
0.2
8.3
1.2
11.6
182
1000
4x2x0.5
0.4
0.2
9.0
1.2
12.3
209
1000
5x2x0.5
0.4
0.2
9.8
1.2
13.1
230
1000
6x2x0.5
0.4
0.3
10.7
1.3
14.6
288
1000
7x2x0.5
0.4
0.3
10.7
1.3
14.6
301
1000
10x2x0.5
0.4
0.3
13.4
1.4
17.6
395
1000
12x2x0.5
0.4
0.3
13.9
1.4
18.0
442
1000
16x2x0.5
0.4
0.3
15.4
1.5
19.7
534
1000
20x2x0.5
0.4
0.3
17.1
1.5
21.5
607
1000
24x2x0.5
0.4
0.3
19.0
1.6
23.6
711
1000
30x2x0.5
0.4
0.3
20.2
1.7
24.9
813
500
1x2x0.75
0.5
0.2
6.5
1.1
9.6
133
1000
2x2x0.75
0.5
0.2
9.2
1.2
12.5
199
1000
3x2x0.75
0.5
0.2
9.8
1.2
13.1
224
1000
4x2x0.75
0.5
0.3
10.7
1.3
14.6
290
1000
5x2x0.75
0.5
0.3
11.6
1.3
15.6
335
1000
6x2x0.75
0.5
0.3
12.7
1.4
16.8
375
1000
7x2x0.75
0.5
0.3
12.7
1.4
16.8
394
1000
10x2x0.75
0.5
0.3
16.1
1.5
20.5
534
1000
12x2x0.75
0.5
0.3
16.7
1.5
21.0
580
1000
16x2x0.75
0.5
0.3
18.6
1.6
23.1
711
1000
20x2x0.75
0.5
0.3
20.7
1.7
25.5
828
500
24x2x0.75
0.5
0.3
23.1
1.8
28.0
969
500
30x2x0.75
0.5
0.3
24.5
1.8
29.4
1105
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
63
KCI
RE-2X(St)YQY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
mm
Kg/Km
meter
0.5
0.2
6.9
1.1
10.0
136
1000
2x2x1
0.5
0.2
9.8
1.2
13.1
211
1000
3x2x1
0.5
0.3
10.4
1.3
14.4
278
1000
4x2x1
0.5
0.3
11.4
1.3
15.3
329
1000
5x2x1
0.5
0.3
12.4
1.3
16.4
367
1000
6x2x1
0.5
0.3
13.6
1.4
17.7
414
1000
7x2x1
0.5
0.3
13.6
1.4
17.7
439
1000
10x2x1
0.5
0.3
17.3
1.5
21.7
599
1000
12x2x1
0.5
0.3
17.9
1.5
22.3
656
1000
16x2x1
0.5
0.3
19.9
1.6
24.5
812
1000
20x2x1
0.5
0.3
22.3
1.7
27.1
975
500
24x2x1
0.5
0.3
24.8
1.8
29.8
1122
500
30x2x1
0.5
0.3
26.4
1.9
31.5
1328
500
Instrument Cables
64
1x2x1.5
0.6
0.2
7.9
1.2
11.2
171
1000
2x2x1.5
0.6
0.3
11.4
1.3
15.4
306
1000
3x2x1.5
0.6
0.3
12.2
1.3
16.1
352
1000
4x2x1.5
0.6
0.3
13.4
1.4
17.5
412
1000
5x2x1.5
0.6
0.3
14.6
1.4
18.8
482
1000
6x2x1.5
0.6
0.3
16.0
1.5
20.4
559
1000
7x2x1.5
0.6
0.3
16.0
1.5
20.4
597
1000
10x2x1.5
0.6
0.3
20.6
1.7
25.3
810
500
12x2x1.5
0.6
0.3
21.3
1.7
26.1
894
500
16x2x1.5
0.6
0.3
23.8
1.8
28.7
1111
500
20x2x1.5
0.6
0.3
26.7
1.9
31.8
1337
500
24x2x1.5
0.6
0.3
30.1
2.0
35.5
1601
500
30x2x1.5
0.6
0.4
32.0
2.1
38.0
1969
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
0.2
8.7
1.2
12.0
208
1000
2x2x2.5
0.6
0.3
12.8
1.4
17.0
371
1000
3x2x2.5
0.6
0.3
13.7
1.4
17.8
454
1000
4x2x2.5
0.6
0.3
15.0
1.4
19.2
522
1000
5x2x2.5
0.6
0.3
16.5
1.5
20.9
626
1000
6x2x2.5
0.6
0.3
18.1
1.6
22.6
713
1000
7x2x2.5
0.6
0.3
18.1
1.6
22.6
769
1000
10x2x2.5
0.6
0.3
23.3
1.8
28.3
1074
500
12x2x2.5
0.6
0.3
24.2
1.8
29.1
1199
500
16x2x2.5
0.6
0.3
27.0
1.9
32.2
1501
500
20x2x2.5
0.6
0.3
30.7
2.0
36.1
1846
500
24x2x2.5
0.6
0.4
34.3
2.2
40.5
2263
500
30x2x2.5
0.6
0.4
36.4
2.3
42.8
2700
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
65
KCI
RE-2X(St)YQY
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Braid of Galvanized Steel Wires
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
Instrument Cables
Criteria
66
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
0.2
6.0
1.1
9.1
127
1000
2x3x0.5
0.4
0.2
8.6
1.2
11.9
192
1000
3x3x0.5
0.4
0.2
9.1
1.2
12.4
216
1000
4x3x0.5
0.4
0.2
10.0
1.2
13.3
251
1000
5x3x0.5
0.4
0.3
10.9
1.3
14.8
324
1000
6x3x0.5
0.4
0.3
11.8
1.3
15.8
355
1000
7x3x0.5
0.4
0.3
11.8
1.3
15.8
373
1000
10x3x0.5
0.4
0.3
15.0
1.5
19.3
497
1000
12x3x0.5
0.4
0.3
15.5
1.5
19.9
561
1000
16x3x0.5
0.4
0.3
17.2
1.5
21.6
658
1000
20x3x0.5
0.4
0.3
19.2
1.6
23.8
789
1000
24x3x0.5
0.4
0.3
21.3
1.7
26.1
904
500
30x3x0.5
0.4
0.3
22.6
1.7
27.4
1056
500
1x3x0.75
0.5
0.2
6.8
1.1
9.9
146
1000
2x3x0.75
0.5
0.2
10.2
1.2
13.5
235
1000
3x3x0.75
0.5
0.3
10.8
1.3
14.8
315
1000
4x3x0.75
0.5
0.3
11.8
1.3
15.8
357
1000
5x3x0.75
0.5
0.3
12.9
1.4
17.1
407
1000
6x3x0.75
0.5
0.3
14.1
1.4
18.3
467
1000
7x3x0.75
0.5
0.3
14.1
1.4
18.3
495
1000
10x3x0.75
0.5
0.3
18.1
1.6
22.6
665
1000
12x3x0.75
0.5
0.3
18.7
1.6
23.2
751
1000
16x3x0.75
0.5
0.3
20.8
1.7
25.6
906
500
20x3x0.75
0.5
0.3
23.3
1.8
28.3
1088
500
24x3x0.75
0.5
0.3
25.9
1.9
31.1
1276
500
30x3x0.75
0.5
0.3
28.0
2.0
33.3
1518
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
67
KCI
RE-2X(St)YQY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
mm
Kg/Km
meter
0.5
0.2
7.2
1.1
10.3
159
1000
2x3x1
0.5
0.3
10.8
1.3
14.8
298
1000
3x3x1
0.5
0.3
11.5
1.3
15.5
344
1000
4x3x1
0.5
0.3
12.6
1.3
16.6
395
1000
5x3x1
0.5
0.3
13.8
1.4
18.0
470
1000
6x3x1
0.5
0.3
15.1
1.4
19.3
518
1000
7x3x1
0.5
0.3
15.1
1.4
19.3
555
1000
10x3x1
0.5
0.3
19.4
1.6
24.0
781
1000
12x3x1
0.5
0.3
20.1
1.6
24.6
864
500
16x3x1
0.5
0.3
22.4
1.7
27.1
1076
500
20x3x1
0.5
0.3
25.1
1.8
30.0
1275
500
24x3x1
0.5
0.3
28.0
1.9
33.1
1501
500
30x3x1
0.5
0.3
30.1
2.0
35.5
1819
500
Instrument Cables
68
1x3x1.5
0.6
0.2
8.3
1.2
11.6
194
1000
2x3x1.5
0.6
0.3
12.7
1.4
16.9
367
1000
3x3x1.5
0.6
0.3
13.5
1.4
17.7
434
1000
4x3x1.5
0.6
0.3
14.9
1.4
19.1
517
1000
5x3x1.5
0.6
0.3
16.4
1.5
20.7
620
1000
6x3x1.5
0.6
0.3
17.9
1.6
22.5
706
1000
7x3x1.5
0.6
0.3
17.9
1.6
22.5
762
1000
10x3x1.5
0.6
0.3
23.1
1.8
28.1
1065
500
12x3x1.5
0.6
0.3
24.0
1.8
28.9
1188
500
16x3x1.5
0.6
0.3
26.8
1.9
31.9
1488
500
20x3x1.5
0.6
0.3
30.5
2.0
35.8
1831
500
24x3x1.5
0.6
0.4
34.0
2.2
40.2
2245
500
30x3x1.5
0.6
0.4
36.1
2.3
42.5
2679
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
0.2
9.2
1.2
12.5
242
1000
2x3x2.5
0.6
0.3
14.3
1.4
18.4
462
1000
3x3x2.5
0.6
0.3
15.2
1.5
19.6
562
1000
4x3x2.5
0.6
0.3
16.8
1.5
21.2
686
1000
5x3x2.5
0.6
0.3
18.5
1.6
23.0
803
1000
6x3x2.5
0.6
0.3
20.3
1.6
24.8
931
500
7x3x2.5
0.6
0.3
20.3
1.6
24.8
1016
500
10x3x2.5
0.6
0.3
26.3
1.9
31.4
1434
500
12x3x2.5
0.6
0.3
27.2
1.9
32.4
1617
500
16x3x2.5
0.6
0.3
30.9
2.0
36.2
2074
500
20x3x2.5
0.6
0.4
34.7
2.2
40.9
2609
500
24x3x2.5
0.6
0.4
38.7
2.4
45.3
3102
500
30x3x2.5
0.6
0.4
41.5
2.5
48.3
3763
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
69
KCI
RE-2X(St)YQY , PiMF
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
Instrument Cables
70
XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
0.2
6.0
1.1
9.1
137
1000
2x2x0.5
0.4
0.2
9.0
1.2
12.3
214
1000
3x2x0.5
0.4
0.2
9.5
1.2
12.8
248
1000
4x2x0.5
0.4
0.2
10.4
1.2
13.7
292
1000
5x2x0.5
0.4
0.3
11.3
1.3
15.3
376
1000
6x2x0.5
0.4
0.3
12.3
1.3
16.3
416
1000
7x2x0.5
0.4
0.3
12.3
1.3
16.3
445
1000
10x2x0.5
0.4
0.3
15.7
1.5
20.0
618
1000
12x2x0.5
0.4
0.3
16.2
1.5
20.5
681
1000
16x2x0.5
0.4
0.3
18.0
1.6
22.5
826
1000
20x2x0.5
0.4
0.3
20.1
1.6
24.7
986
500
24x2x0.5
0.4
0.3
22.3
1.7
27.1
1161
500
30x2x0.5
0.4
0.3
23.7
1.8
28.7
1362
500
1x2x0.75
0.5
0.2
6.9
1.1
10.0
153
1000
2x2x0.75
0.5
0.3
10.4
1.3
14.4
281
1000
3x2x0.75
0.5
0.3
11.1
1.3
15.0
339
1000
4x2x0.75
0.5
0.3
12.1
1.3
16.1
387
1000
5x2x0.75
0.5
0.3
13.3
1.4
17.4
445
1000
6x2x0.75
0.5
0.3
14.5
1.4
18.7
511
1000
7x2x0.75
0.5
0.3
14.5
1.4
18.7
547
1000
10x2x0.75
0.5
0.3
18.6
1.6
23.1
758
1000
12x2x0.75
0.5
0.3
19.2
1.6
23.8
837
1000
16x2x0.75
0.5
0.3
21.4
1.7
26.2
1020
500
20x2x0.75
0.5
0.3
24.0
1.8
28.9
1230
500
24x2x0.75
0.5
0.3
26.7
1.9
31.9
1446
500
30x2x0.75
0.5
0.3
28.8
2.0
34.1
1729
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
71
KCI
RE-2X(St)YQY , PiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
mm
Kg/Km
meter
0.5
0.2
7.2
1.1
10.3
157
1000
2x2x1
0.5
0.3
11.1
1.3
15.0
297
1000
3x2x1
0.5
0.3
11.8
1.3
15.7
342
1000
4x2x1
0.5
0.3
12.9
1.4
17.1
399
1000
5x2x1
0.5
0.3
14.1
1.4
18.3
466
1000
6x2x1
0.5
0.3
15.5
1.5
19.8
542
1000
7x2x1
0.5
0.3
15.5
1.5
19.8
577
1000
10x2x1
0.5
0.3
19.9
1.6
24.4
770
1000
12x2x1
0.5
0.3
20.6
1.6
25.1
850
500
16x2x1
0.5
0.3
22.9
1.7
27.7
1057
500
20x2x1
0.5
0.3
25.7
1.8
30.6
1272
500
24x2x1
0.5
0.3
29.0
2.0
34.4
1539
500
30x2x1
0.5
0.3
30.8
2.0
36.2
1781
500
Instrument Cables
72
1x2x1.5
0.6
0.2
8.2
1.2
11.5
186
1000
2x2x1.5
0.6
0.3
12.8
1.4
17.0
354
1000
3x2x1.5
0.6
0.3
13.7
1.4
17.8
429
1000
4x2x1.5
0.6
0.3
15.1
1.4
19.2
490
1000
5x2x1.5
0.6
0.3
16.5
1.5
20.9
586
1000
6x2x1.5
0.6
0.3
18.1
1.6
22.7
665
1000
7x2x1.5
0.6
0.3
18.1
1.6
22.7
714
1000
10x2x1.5
0.6
0.3
23.4
1.8
28.4
997
500
12x2x1.5
0.6
0.3
24.3
1.8
29.2
1107
500
16x2x1.5
0.6
0.3
27.1
1.9
32.3
1379
500
20x2x1.5
0.6
0.3
30.8
2.0
36.2
1694
500
24x2x1.5
0.6
0.4
34.4
2.2
40.6
2081
500
30x2x1.5
0.6
0.4
36.5
2.3
42.9
2472
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.6
0.2
9.1
1.2
12.4
227
1000
2x2x2.5
0.6
0.3
14.3
1.4
18.5
436
1000
3x2x2.5
0.6
0.3
15.3
1.5
19.7
542
1000
4x2x2.5
0.6
0.3
16.9
1.5
21.2
633
1000
5x2x2.5
0.6
0.3
18.6
1.6
23.1
756
1000
6x2x2.5
0.6
0.3
20.4
1.6
24.9
851
500
7x2x2.5
0.6
0.3
20.4
1.6
24.9
922
500
10x2x2.5
0.6
0.3
26.4
1.9
31.5
1299
500
12x2x2.5
0.6
0.3
27.4
1.9
32.5
1456
500
16x2x2.5
0.6
0.4
31.0
2.1
37.0
1971
500
20x2x2.5
0.6
0.4
34.8
2.2
41.0
2340
500
24x2x2.5
0.6
0.4
38.9
2.4
45.5
2779
500
30x2x2.5
0.6
0.4
41.7
2.5
48.5
3359
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
73
KCI
RE-2X(St)YQY , TiMF
150/250 V (300 V)
IEC 60092-376
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
Instrument Cables
74
XLPE
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YQY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
0.4
0.2
6.3
1.1
9.4
146
1000
2x3x0.5
0.4
0.2
9.9
1.2
13.2
237
1000
3x3x0.5
0.4
0.3
10.5
1.3
14.4
314
1000
4x3x0.5
0.4
0.3
11.5
1.3
15.4
375
1000
5x3x0.5
0.4
0.3
12.5
1.4
16.7
431
1000
6x3x0.5
0.4
0.3
13.6
1.4
17.8
495
1000
7x3x0.5
0.4
0.3
13.6
1.4
17.8
530
1000
10x3x0.5
0.4
0.3
17.4
1.5
21.8
705
1000
12x3x0.5
0.4
0.3
18.0
1.6
22.6
792
1000
16x3x0.5
0.4
0.3
20.1
1.6
24.6
978
500
20x3x0.5
0.4
0.3
22.5
1.7
27.2
1181
500
24x3x0.5
0.4
0.3
25.0
1.8
30.0
1367
500
30x3x0.5
0.4
0.3
26.6
1.9
31.7
1633
500
1x3x0.75
0.5
0.2
7.2
1.1
10.3
172
1000
2x3x0.75
0.5
0.3
11.5
1.3
15.5
328
1000
3x3x0.75
0.5
0.3
12.3
1.3
16.2
383
1000
4x3x0.75
0.5
0.3
13.5
1.4
17.6
451
1000
5x3x0.75
0.5
0.3
14.8
1.4
18.9
529
1000
6x3x0.75
0.5
0.3
16.1
1.5
20.5
614
1000
7x3x0.75
0.5
0.3
16.1
1.5
20.5
660
1000
10x3x0.75
0.5
0.3
20.8
1.7
25.5
897
500
12x3x0.75
0.5
0.3
21.5
1.7
26.2
997
500
16x3x0.75
0.5
0.3
24.0
1.8
28.9
1247
500
20x3x0.75
0.5
0.3
26.9
1.9
32.0
1505
500
24x3x0.75
0.5
0.3
30.4
2.0
35.7
1801
500
30x3x0.75
0.5
0.4
32.3
2.1
38.3
2217
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
75
KCI
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
RE-2X(St)YQY , TiMF
mm
mm
Kg/Km
meter
0.5
0.2
7.6
1.1
10.7
174
1000
2x3x1
0.5
0.3
12.3
1.3
16.2
338
1000
3x3x1
0.5
0.3
13.1
1.4
17.2
404
1000
4x3x1
0.5
0.3
14.3
1.4
18.5
484
1000
5x3x1
0.5
0.3
15.7
1.5
20.1
573
1000
6x3x1
0.5
0.3
17.2
1.5
21.6
640
1000
7x3x1
0.5
0.3
17.2
1.5
21.6
688
1000
10x3x1
0.5
0.3
22.2
1.7
27.0
961
500
12x3x1
0.5
0.3
23.0
1.7
27.8
1068
500
16x3x1
0.5
0.3
25.7
1.8
30.7
1333
500
20x3x1
0.5
0.3
29.2
2.0
34.6
1654
500
24x3x1
0.5
0.4
32.6
2.1
38.6
2015
500
30x3x1
0.5
0.4
34.6
2.2
40.8
2358
500
Instrument Cables
76
1x3x1.5
0.6
0.2
8.7
1.2
12.0
217
1000
2x3x1.5
0.6
0.3
14.3
1.4
18.4
426
1000
3x3x1.5
0.6
0.3
15.2
1.4
19.4
500
1000
4x3x1.5
0.6
0.3
16.8
1.5
21.2
617
1000
5x3x1.5
0.6
0.3
18.5
1.6
23.0
716
1000
6x3x1.5
0.6
0.3
20.3
1.6
24.8
828
500
7x3x1.5
0.6
0.3
20.3
1.6
24.8
896
500
10x3x1.5
0.6
0.3
26.3
1.9
31.4
1263
500
12x3x1.5
0.6
0.3
27.2
1.9
32.4
1413
500
16x3x1.5
0.6
0.3
30.9
2.0
36.2
1803
500
20x3x1.5
0.6
0.4
34.7
2.2
40.9
2271
500
24x3x1.5
0.6
0.4
38.7
2.4
45.3
2696
500
30x3x1.5
0.6
0.4
41.5
2.5
48.3
3258
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Insulation
thickness
mm2
Sheath thickness
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY , TiMF
0.6
0.2
9.6
1.2
12.9
261
1000
2x3x2.5
0.6
0.3
16.0
1.5
20.3
537
1000
3x3x2.5
0.6
0.3
17.1
1.5
21.4
650
1000
4x3x2.5
0.6
0.3
18.9
1.6
23.4
803
1000
5x3x2.5
0.6
0.3
20.8
1.7
25.5
940
500
6x3x2.5
0.6
0.3
22.8
1.7
27.6
1088
500
7x3x2.5
0.6
0.3
22.8
1.7
27.6
1188
500
10x3x2.5
0.6
0.3
30.1
2.0
35.4
1703
500
12x3x2.5
0.6
0.4
31.2
2.1
37.2
2033
500
16x3x2.5
0.6
0.4
34.9
2.2
41.1
2515
500
20x3x2.5
0.6
0.4
39.2
2.4
45.8
3074
500
24x3x2.5
0.6
0.4
44.2
2.6
51.2
3695
250
30x3x2.5
0.6
0.4
47.0
2.7
54.2
4379
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
77
KCI
RE-2X(St)YQY Fire Resistant
IEC 60092-376 150/250 V (300 V)
RE-2X(St)YQY Multi-Core
RE-2X(St)YQY Multi-Pair
RE-2X(St)YQY Multi-Triple
RE-2X(St)YQY PiMF
RE-2X(St)YQY TiMF
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
RE-2X(St)HQH
Fire Resistant
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
RE-2X(St)QY
IEC 60092-376
Fire Resistant
KCI
150/250 V (300 V)
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
80
IEC 60331
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
mm
mm
Kg/Km
meter
KCI
RE-2X(St)QY
Fire Resistant
0.4
0.2
6.6
1.1
9.7
131
1000
3x0.5
0.4
0.2
7.0
1.1
10.1
149
1000
4x0.5
0.4
0.2
7.6
1.1
10.7
163
1000
5x0.5
0.4
0.2
8.2
1.1
11.3
177
1000
6x0.5
0.4
0.2
8.8
1.2
12.1
204
1000
7x0.5
0.4
0.2
8.8
1.2
12.1
212
1000
8x0.5
0.4
0.2
10.1
1.2
13.4
241
1000
10x0.5
0.4
0.3
11.0
1.3
15.0
311
1000
12x0.5
0.4
0.3
11.4
1.3
15.3
331
1000
16x0.5
0.4
0.3
12.5
1.3
16.5
378
1000
20x0.5
0.4
0.3
13.9
1.4
18.1
450
1000
24x0.5
0.4
0.3
15.4
1.4
19.5
515
1000
30x0.5
0.4
0.3
16.3
1.4
20.4
574
1000
2x0.75
0.5
0.2
7.5
1.1
10.6
153
1000
3x0.75
0.5
0.2
7.9
1.1
11.0
169
1000
4x0.75
0.5
0.2
8.6
1.2
11.9
199
1000
5x0.75
0.5
0.2
9.3
1.2
12.6
219
1000
6x0.75
0.5
0.2
10.1
1.2
13.4
245
1000
7x0.75
0.5
0.2
10.1
1.2
13.4
257
1000
8x0.75
0.5
0.3
11.6
1.3
15.6
331
1000
10x0.75
0.5
0.3
12.6
1.3
16.6
367
1000
12x0.75
0.5
0.3
13.1
1.3
17.0
395
1000
16x0.75
0.5
0.3
14.5
1.4
18.6
483
1000
20x0.75
0.5
0.3
16.1
1.5
20.4
573
1000
24x0.75
0.5
0.3
17.8
1.5
22.2
640
1000
30x0.75
0.5
0.3
18.9
1.5
23.2
743
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
81
KCI
RE-2X(St)YQY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.5
0.2
7.8
1.1
10.9
157
1000
3x1
0.5
0.2
8.3
1.1
11.4
176
1000
4x1
0.5
0.2
9.0
1.2
12.3
210
1000
5x1
0.5
0.2
9.8
1.2
13.1
233
1000
6x1
0.5
0.3
10.6
1.2
14.3
286
1000
7x1
0.5
0.3
10.6
1.2
14.3
300
1000
8x1
0.5
0.3
12.3
1.3
16.2
356
1000
10x1
0.5
0.3
13.4
1.3
17.3
399
1000
12x1
0.5
0.3
13.8
1.4
18.0
457
1000
16x1
0.5
0.3
15.3
1.4
19.5
548
1000
20x1
0.5
0.3
17.1
1.5
21.4
636
1000
24x1
0.5
0.3
18.9
1.5
23.3
737
1000
30x1
0.5
0.3
20.0
1.6
24.6
849
500
Instrument Cables
82
2x1.5
0.6
0.2
8.8
1.2
12.1
192
1000
3x1.5
0.6
0.2
9.4
1.2
12.7
219
1000
4x1.5
0.6
0.2
10.2
1.2
13.5
256
1000
5x1.5
0.6
0.3
11.1
1.3
15.1
331
1000
6x1.5
0.6
0.3
12.1
1.3
16.0
365
1000
7x1.5
0.6
0.3
12.1
1.3
16.0
385
1000
8x1.5
0.6
0.3
14.1
1.4
18.2
454
1000
10x1.5
0.6
0.3
15.4
1.4
19.5
527
1000
12x1.5
0.6
0.3
15.9
1.4
20.0
575
1000
16x1.5
0.6
0.3
17.7
1.5
22.0
690
1000
20x1.5
0.6
0.3
19.7
1.6
24.3
831
1000
24x1.5
0.6
0.3
21.9
1.7
26.7
976
500
30x1.5
0.6
0.3
23.2
1.7
28.0
1119
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
Sheath thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY
0.6
0.2
9.7
1.2
13.0
223
1000
3x2.5
0.6
0.2
10.3
1.2
13.6
266
1000
4x2.5
0.6
0.3
11.2
1.3
15.2
353
1000
5x2.5
0.6
0.3
12.3
1.3
16.2
396
1000
6x2.5
0.6
0.3
13.4
1.4
17.5
448
1000
7x2.5
0.6
0.3
13.4
1.4
17.5
479
1000
8x2.5
0.6
0.3
15.6
1.4
19.7
567
1000
10x2.5
0.6
0.3
17.0
1.5
21.4
655
1000
12x2.5
0.6
0.3
17.6
1.5
22.0
723
1000
16x2.5
0.6
0.3
19.6
1.6
24.2
902
1000
20x2.5
0.6
0.3
22.0
1.7
26.7
1087
500
24x2.5
0.6
0.3
24.4
1.8
29.4
1256
500
30x2.5
0.6
0.3
25.9
1.8
30.9
1481
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
83
KCI
RE-2X(St)YQY
IEC 60092-376
Fire Resistant
150/250 V (300 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
84
Black,Blue (Numbered)
IEC 60331
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
mm
mm
Kg/Km
meter
KCI
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
Sheath thickness
RE-2X(St)YQY
0.4
0.2
6.6
1.1
9.7
131
1000
2x2x0.5
0.4
0.2
9.4
1.2
12.7
195
1000
3x2x0.5
0.4
0.2
10.0
1.2
13.3
224
1000
4x2x0.5
0.4
0.3
10.9
1.3
14.9
296
1000
5x2x0.5
0.4
0.3
11.9
1.3
15.9
324
1000
6x2x0.5
0.4
0.3
13.0
1.3
17.0
354
1000
7x2x0.5
0.4
0.3
13.0
1.3
17.0
370
1000
10x2x0.5
0.4
0.3
16.6
1.4
20.7
501
1000
12x2x0.5
0.4
0.3
17.2
1.5
21.5
550
1000
16x2x0.5
0.4
0.3
19.1
1.5
23.4
660
1000
20x2x0.5
0.4
0.3
21.3
1.6
25.9
765
500
24x2x0.5
0.4
0.3
23.7
1.7
28.5
895
500
30x2x0.5
0.4
0.3
25.2
1.7
30.0
1013
500
1x2x0.75
0.5
0.2
7.5
1.1
10.6
153
1000
2x2x0.75
0.5
0.3
10.8
1.3
14.7
261
1000
3x2x0.75
0.5
0.3
11.5
1.3
15.4
308
1000
4x2x0.75
0.5
0.3
12.6
1.3
16.5
345
1000
5x2x0.75
0.5
0.3
13.8
1.4
17.9
407
1000
6x2x0.75
0.5
0.3
15.0
1.4
19.2
441
1000
7x2x0.75
0.5
0.3
15.0
1.4
19.2
464
1000
10x2x0.75
0.5
0.3
19.3
1.6
23.8
648
1000
12x2x0.75
0.5
0.3
20.0
1.6
24.5
704
500
16x2x0.75
0.5
0.3
22.3
1.7
27.0
861
500
20x2x0.75
0.5
0.3
24.9
1.7
29.7
992
500
24x2x0.75
0.5
0.3
27.8
1.8
32.7
1161
500
30x2x0.75
0.5
0.3
29.5
1.9
34.7
1364
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
85
KCI
RE-2X(St)YQY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.5
0.2
7.8
1.1
10.9
157
1000
2x2x1
0.5
0.3
11.4
1.3
15.3
289
1000
3x2x1
0.5
0.3
12.1
1.3
16.1
327
1000
4x2x1
0.5
0.3
13.3
1.3
17.2
371
1000
5x2x1
0.5
0.3
14.6
1.4
18.7
441
1000
6x2x1
0.5
0.3
15.9
1.4
20.1
501
1000
7x2x1
0.5
0.3
15.9
1.4
20.1
530
1000
10x2x1
0.5
0.3
20.5
1.6
25.0
716
500
12x2x1
0.5
0.3
21.2
1.6
25.7
784
500
16x2x1
0.5
0.3
23.6
1.7
28.4
967
500
20x2x1
0.5
0.3
26.5
1.8
31.5
1159
500
24x2x1
0.5
0.3
29.5
1.9
34.7
1358
500
30x2x1
0.5
0.4
31.8
2.0
37.6
1707
500
Instrument Cables
86
1x2x1.5
0.6
0.2
8.8
1.2
12.1
193
1000
2x2x1.5
0.6
0.3
13.0
1.3
17.0
336
1000
3x2x1.5
0.6
0.3
13.9
1.4
18.0
412
1000
4x2x1.5
0.6
0.3
15.3
1.4
19.4
467
1000
5x2x1.5
0.6
0.3
16.8
1.5
21.1
558
1000
6x2x1.5
0.6
0.3
18.4
1.5
22.7
620
1000
7x2x1.5
0.6
0.3
18.4
1.5
22.7
663
1000
10x2x1.5
0.6
0.3
23.7
1.7
28.5
925
500
12x2x1.5
0.6
0.3
24.6
1.7
29.3
1022
500
16x2x1.5
0.6
0.3
27.5
1.8
32.4
1268
500
20x2x1.5
0.6
0.4
31.3
2.0
37.1
1670
500
24x2x1.5
0.6
0.4
34.9
2.1
40.9
1919
500
30x2x1.5
0.6
0.4
37.1
2.2
43.3
2273
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
Sheath thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY
0.6
0.2
9.7
1.2
13.0
224
1000
2x2x2.5
0.6
0.3
14.4
1.4
18.5
418
1000
3x2x2.5
0.6
0.3
15.4
1.4
19.5
507
1000
4x2x2.5
0.6
0.3
16.9
1.5
21.3
598
1000
5x2x2.5
0.6
0.3
18.6
1.5
23.0
701
1000
6x2x2.5
0.6
0.3
20.4
1.6
25.0
798
500
7x2x2.5
0.6
0.3
20.4
1.6
25.0
860
500
10x2x2.5
0.6
0.3
26.5
1.8
31.4
1196
500
12x2x2.5
0.6
0.3
27.5
1.8
32.4
1334
500
16x2x2.5
0.6
0.4
31.1
2.0
36.9
1812
500
20x2x2.5
0.6
0.4
34.9
2.1
40.9
2144
500
24x2x2.5
0.6
0.4
39.0
2.3
45.4
2544
500
30x2x2.5
0.6
0.4
41.5
2.4
48.1
3027
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
87
RE-2X(St)YQY
IEC 60092-376
Fire Resistant
KCI
150/250 V (300 V)
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Braid of Galvanized Steel Wires
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
IEC 60331
Instrument Cables
Criteria
88
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY
0.4
0.2
7.0
1.1
10.1
149
1000
2x3x0.5
0.4
0.3
10.4
1.2
14.2
252
1000
3x3x0.5
0.4
0.3
11.1
1.3
15.0
306
1000
4x3x0.5
0.4
0.3
12.1
1.3
16.1
343
1000
5x3x0.5
0.4
0.3
13.3
1.3
17.2
382
1000
6x3x0.5
0.4
0.3
14.5
1.4
18.7
445
1000
7x3x0.5
0.4
0.3
14.5
1.4
18.7
470
1000
10x3x0.5
0.4
0.3
18.6
1.5
22.9
637
1000
12x3x0.5
0.4
0.3
19.2
1.5
23.6
694
1000
16x3x0.5
0.4
0.3
21.4
1.6
26.0
831
500
20x3x0.5
0.4
0.3
24.0
1.7
28.7
997
500
24x3x0.5
0.4
0.3
26.7
1.8
31.7
1167
500
30x3x0.5
0.4
0.3
28.4
1.8
33.3
1338
500
1x3x0.75
0.5
0.2
7.9
1.1
11.0
169
1000
2x3x0.75
0.5
0.3
12.0
1.3
15.9
314
1000
3x3x0.75
0.5
0.3
12.7
1.3
16.7
359
1000
4x3x0.75
0.5
0.3
14.0
1.4
18.1
433
1000
5x3x0.75
0.5
0.3
15.4
1.4
19.5
500
1000
6x3x0.75
0.5
0.3
16.8
1.5
21.2
562
1000
7x3x0.75
0.5
0.3
16.8
1.5
21.2
598
1000
10x3x0.75
0.5
0.3
21.6
1.6
26.2
797
500
12x3x0.75
0.5
0.3
22.4
1.7
27.2
910
500
16x3x0.75
0.5
0.3
25.0
1.7
29.8
1087
500
20x3x0.75
0.5
0.3
28.1
1.9
33.2
1322
500
24x3x0.75
0.5
0.4
31.7
2.0
37.5
1678
500
30x3x0.75
0.5
0.4
33.7
2.1
39.7
1941
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
89
KCI
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
Sheath thickness
RE-2X(St)YQY
Fire Resistant
mm
mm
Kg/Km
meter
0.5
0.2
8.3
1.1
11.4
177
1000
2x3x1
0.5
0.3
12.6
1.3
16.6
334
1000
3x3x1
0.5
0.3
13.5
1.3
17.4
388
1000
4x3x1
0.5
0.3
14.8
1.4
19.0
473
1000
5x3x1
0.5
0.3
16.3
1.4
20.4
549
1000
6x3x1
0.5
0.3
17.8
1.5
22.2
622
1000
7x3x1
0.5
0.3
17.8
1.5
22.2
666
1000
10x3x1
0.5
0.3
23.0
1.7
27.7
929
500
12x3x1
0.5
0.3
23.8
1.7
28.6
1029
500
16x3x1
0.5
0.3
26.6
1.8
31.6
1279
500
20x3x1
0.5
0.3
29.9
1.9
35.0
1539
500
24x3x1
0.5
0.4
33.7
2.0
39.5
1916
500
30x3x1
0.5
0.4
35.9
2.1
41.9
2274
500
Instrument Cables
90
1x3x1.5
0.6
0.2
9.4
1.2
12.7
220
1000
2x3x1.5
0.6
0.3
14.5
1.4
18.7
421
1000
3x3x1.5
0.6
0.3
15.5
1.4
19.6
511
1000
4x3x1.5
0.6
0.3
17.1
1.5
21.4
604
1000
5x3x1.5
0.6
0.3
18.8
1.5
23.1
710
1000
6x3x1.5
0.6
0.3
20.6
1.6
25.2
808
500
7x3x1.5
0.6
0.3
20.6
1.6
25.2
872
500
10x3x1.5
0.6
0.3
26.7
1.8
31.7
1215
500
12x3x1.5
0.6
0.3
27.7
1.8
32.7
1357
500
16x3x1.5
0.6
0.4
31.4
2.0
37.2
1842
500
20x3x1.5
0.6
0.4
35.3
2.1
41.3
2182
500
24x3x1.5
0.6
0.4
39.3
2.3
45.7
2591
500
30x3x1.5
0.6
0.4
41.9
2.4
48.5
3084
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
Sheath thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY
0.6
0.2
10.3
1.2
13.6
268
1000
2x3x2.5
0.6
0.3
16.1
1.4
20.2
515
1000
3x3x2.5
0.6
0.3
17.2
1.5
21.5
632
1000
4x3x2.5
0.6
0.3
19.0
1.5
23.3
768
1000
5x3x2.5
0.6
0.3
20.9
1.6
25.5
897
500
6x3x2.5
0.6
0.3
23.0
1.7
27.7
1051
500
7x3x2.5
0.6
0.3
23.0
1.7
27.7
1144
500
10x3x2.5
0.6
0.3
29.9
1.9
35.0
1593
500
12x3x2.5
0.6
0.4
31.4
2.0
37.2
1940
500
16x3x2.5
0.6
0.4
35.1
2.1
41.1
2395
500
20x3x2.5
0.6
0.4
39.4
2.3
45.8
2926
500
24x3x2.5
0.6
0.4
44.5
2.5
51.3
3519
250
30x3x2.5
0.6
0.4
47.3
2.6
54.3
4163
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
91
KCI
RE-2X(St)YQY , PiMF
IEC 60092-376
Fire Resistant
150/250 V (300 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
92
Extruded PVC
Braid of Galvanized Steel Wires
Extruded PVC
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY , PiMF
0.4
0.2
7.0
1.1
10.1
158
1000
2x2x0.5
0.4
0.3
10.7
1.2
14.4
272
1000
3x2x0.5
0.4
0.3
11.4
1.3
15.3
333
1000
4x2x0.5
0.4
0.3
12.4
1.3
16.4
380
1000
5x2x0.5
0.4
0.3
13.6
1.3
17.6
442
1000
6x2x0.5
0.4
0.3
14.9
1.4
19.0
499
1000
7x2x0.5
0.4
0.3
14.9
1.4
19.0
532
1000
10x2x0.5
0.4
0.3
19.1
1.5
23.4
725
1000
12x2x0.5
0.4
0.3
19.7
1.6
24.3
810
1000
16x2x0.5
0.4
0.3
22.0
1.6
26.6
991
500
20x2x0.5
0.4
0.3
24.7
1.7
29.4
1169
500
24x2x0.5
0.4
0.3
27.5
1.8
32.4
1374
500
30x2x0.5
0.4
0.3
29.2
1.9
34.3
1632
500
1x2x0.75
0.5
0.2
7.8
1.1
10.9
174
1000
2x2x0.75
0.5
0.3
12.1
1.3
16.1
326
1000
3x2x0.75
0.5
0.3
12.9
1.3
16.9
377
1000
4x2x0.75
0.5
0.3
14.2
1.4
18.4
457
1000
5x2x0.75
0.5
0.3
15.6
1.4
19.7
529
1000
6x2x0.75
0.5
0.3
17.1
1.5
21.4
597
1000
7x2x0.75
0.5
0.3
17.1
1.5
21.4
638
1000
10x2x0.75
0.5
0.3
22.0
1.6
26.5
874
500
12x2x0.75
0.5
0.3
22.8
1.7
27.5
978
500
16x2x0.75
0.5
0.3
25.4
1.8
30.4
1211
500
20x2x0.75
0.5
0.3
28.5
1.9
33.7
1433
500
24x2x0.75
0.5
0.4
32.2
2.0
38.0
1812
500
30x2x0.75
0.5
0.4
34.3
2.1
40.3
2107
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
93
KCI
RE-2X(St)YQY , PiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.5
0.2
8.2
1.1
11.3
173
1000
2x2x1
0.5
0.3
12.8
1.3
16.7
329
1000
3x2x1
0.5
0.3
13.6
1.3
17.6
396
1000
4x2x1
0.5
0.3
15.0
1.4
19.1
457
1000
5x2x1
0.5
0.3
16.4
1.4
20.6
535
1000
6x2x1
0.5
0.3
18.0
1.5
22.4
605
1000
7x2x1
0.5
0.3
18.0
1.5
22.4
646
1000
10x2x1
0.5
0.3
23.3
1.7
28.0
901
500
12x2x1
0.5
0.3
24.1
1.7
28.9
995
500
16x2x1
0.5
0.3
26.9
1.8
31.9
1233
500
20x2x1
0.5
0.3
30.2
1.9
35.4
1481
500
24x2x1
0.5
0.4
34.2
2.1
40.2
1865
500
30x2x1
0.5
0.4
36.3
2.1
42.3
2187
500
Instrument Cables
94
1x2x1.5
0.6
0.2
9.2
1.2
12.5
209
1000
2x2x1.5
0.6
0.3
14.6
1.4
18.7
404
1000
3x2x1.5
0.6
0.3
15.5
1.4
19.7
485
1000
4x2x1.5
0.6
0.3
17.1
1.5
21.5
569
1000
5x2x1.5
0.6
0.3
18.9
1.5
23.2
665
1000
6x2x1.5
0.6
0.3
20.7
1.6
25.2
755
500
7x2x1.5
0.6
0.3
20.7
1.6
25.2
810
500
10x2x1.5
0.6
0.3
26.8
1.8
31.8
1126
500
12x2x1.5
0.6
0.3
27.8
1.8
32.8
1250
500
16x2x1.5
0.6
0.4
31.5
2.0
37.3
1700
500
20x2x1.5
0.6
0.4
35.4
2.1
41.4
2004
500
24x2x1.5
0.6
0.4
39.5
2.3
45.9
2378
500
30x2x1.5
0.6
0.4
42.0
2.4
48.6
2818
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
Sheath thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY , PiMF
0.6
0.2
10.0
1.2
13.3
250
1000
2x2x2.5
0.6
0.3
16.0
1.4
20.2
484
1000
3x2x2.5
0.6
0.3
17.2
1.5
21.5
584
1000
4x2x2.5
0.6
0.3
18.9
1.5
23.3
705
1000
5x2x2.5
0.6
0.3
20.9
1.6
25.4
818
500
6x2x2.5
0.6
0.3
22.9
1.7
27.7
956
500
7x2x2.5
0.6
0.3
22.9
1.7
27.7
1034
500
10x2x2.5
0.6
0.3
29.8
1.9
35.0
1435
500
12x2x2.5
0.6
0.4
31.3
2.0
37.1
1751
500
16x2x2.5
0.6
0.4
35.0
2.1
41.0
2143
500
20x2x2.5
0.6
0.4
39.4
2.3
45.8
2611
500
24x2x2.5
0.6
0.4
44.4
2.5
51.2
3142
250
30x2x2.5
0.6
0.4
47.2
2.6
54.2
3692
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
95
KCI
RE-2X(St)YQY , TiMF
IEC 60092-376
Fire Resistant
150/250 V (300 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
96
IEC 60331
Criteria
Blue,White,Red (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
40.4
26
19.2
12.8
7.86
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 5
minutes
1.5 kV A.C
K.V
300
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY , TiMF
0.4
0.2
7.4
1.1
10.5
170
1000
2x3x0.5
0.4
0.3
11.8
1.3
15.8
323
1000
3x3x0.5
0.4
0.3
12.6
1.3
16.5
374
1000
4x3x0.5
0.4
0.3
13.8
1.3
17.8
445
1000
5x3x0.5
0.4
0.3
15.1
1.4
19.3
506
1000
6x3x0.5
0.4
0.3
16.6
1.4
20.7
584
1000
7x3x0.5
0.4
0.3
16.6
1.4
20.7
625
1000
10x3x0.5
0.4
0.3
21.3
1.6
25.9
850
500
12x3x0.5
0.4
0.3
22.1
1.6
26.6
962
500
16x3x0.5
0.4
0.3
24.7
1.7
29.4
1174
500
20x3x0.5
0.4
0.3
27.7
1.8
32.6
1415
500
24x3x0.5
0.4
0.3
30.8
1.9
36.0
1663
500
30x3x0.5
0.4
0.4
33.2
2.0
39.0
2086
500
1x3x0.75
0.5
0.2
8.2
1.1
11.3
191
1000
2x3x0.75
0.5
0.3
13.5
1.3
17.4
367
1000
3x3x0.75
0.5
0.3
14.4
1.4
18.5
455
1000
4x3x0.75
0.5
0.3
15.8
1.4
20.0
540
1000
5x3x0.75
0.5
0.3
17.4
1.5
21.7
621
1000
6x3x0.75
0.5
0.3
19.1
1.5
23.4
715
1000
7x3x0.75
0.5
0.3
19.1
1.5
23.4
768
1000
10x3x0.75
0.5
0.3
24.7
1.7
29.4
1043
500
12x3x0.75
0.5
0.3
25.5
1.8
30.5
1196
500
16x3x0.75
0.5
0.3
28.6
1.9
33.7
1465
500
20x3x0.75
0.5
0.4
32.5
2.0
38.3
1896
500
24x3x0.75
0.5
0.4
36.2
2.2
42.4
2248
500
30x3x0.75
0.5
0.4
38.5
2.2
44.7
2605
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
97
KCI
RE-2X(St)YQY , TiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
mm2
Sheath thickness
Diameter Under
Armour
150/250 V (300 V)
Armour Wire
Diameter
IEC 60092-376
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.5
0.2
8.6
1.2
11.9
204
1000
2x3x1
0.5
0.3
14.2
1.4
18.4
401
1000
3x3x1
0.5
0.3
15.2
1.4
19.3
463
1000
4x3x1
0.5
0.3
16.7
1.4
20.9
558
1000
5x3x1
0.5
0.3
18.4
1.5
22.7
644
1000
6x3x1
0.5
0.3
20.2
1.6
24.7
754
500
7x3x1
0.5
0.3
20.2
1.6
24.7
810
500
10x3x1
0.5
0.3
26.1
1.8
31.1
1126
500
12x3x1
0.5
0.3
27.1
1.8
32.0
1251
500
16x3x1
0.5
0.3
30.3
1.9
35.4
1559
500
20x3x1
0.5
0.4
34.4
2.1
40.4
2007
500
24x3x1
0.5
0.4
38.4
2.2
44.6
2361
500
30x3x1
0.5
0.4
40.9
2.3
47.3
2763
500
Instrument Cables
98
1x3x1.5
0.6
0.2
9.7
1.2
13.0
237
1000
2x3x1.5
0.6
0.3
16.2
1.4
20.4
482
1000
3x3x1.5
0.6
0.3
17.3
1.5
21.7
582
1000
4x3x1.5
0.6
0.3
19.2
1.5
23.5
701
1000
5x3x1.5
0.6
0.3
21.1
1.6
25.7
814
500
6x3x1.5
0.6
0.3
23.2
1.7
27.9
952
500
7x3x1.5
0.6
0.3
23.2
1.7
27.9
1028
500
10x3x1.5
0.6
0.3
30.2
1.9
35.3
1429
500
12x3x1.5
0.6
0.4
31.7
2.0
37.5
1744
500
16x3x1.5
0.6
0.4
35.4
2.1
41.4
2133
500
20x3x1.5
0.6
0.4
39.8
2.3
46.2
2599
500
24x3x1.5
0.6
0.4
44.9
2.5
51.7
3128
250
30x3x1.5
0.6
0.4
47.8
2.6
54.8
3694
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
mm
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm2
Overall
Diameter
Armour Wire
Diameter
150/250 V (300 V)
Insulation
thickness
IEC 60092-376
Sheath thickness
Fire Resistant
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YQY , TiMF
0.6
0.3
10.6
1.3
14.6
318
1000
2x3x2.5
0.6
0.3
17.9
1.5
22.3
580
1000
3x3x2.5
0.6
0.3
19.2
1.6
23.7
736
1000
4x3x2.5
0.6
0.3
21.2
1.6
25.8
871
500
5x3x2.5
0.6
0.3
23.4
1.7
28.2
1043
500
6x3x2.5
0.6
0.3
25.8
1.8
30.7
1219
500
7x3x2.5
0.6
0.3
25.8
1.8
30.7
1328
500
10x3x2.5
0.6
0.4
34.0
2.1
40.0
1975
500
12x3x2.5
0.6
0.4
35.2
2.1
41.2
2215
500
16x3x2.5
0.6
0.4
39.5
2.3
45.9
2807
500
20x3x2.5
0.6
0.4
44.8
2.5
51.6
3471
250
24x3x2.5
0.6
0.4
50.0
2.7
57.2
4092
250
30x3x2.5
0.6
0.4
53.2
2.8
60.6
7685
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
99
KCI
KCI
Scope :
This sectional specification covers multi-element cables suitable for connecting instruments and control
systems for analogue or digital signal transmission.
They may or may not be screened and optionally may incorporate armouring and/or moisture or
environmental protection layers.
The cables shall have a mechanically robust construction and electrical transmission handling properties.
The electrical, mechanical, transmission and environmental performance characteristics of the cables, related
to their reference test methods are detailed .
Cables covered by this specification have maximum rated voltages of 90 V, 300 V and 500 V a.c.
These cables shall not be connected directly to mains electricity supply or other low impedance sources.
Multi-element cables for use in analogue,
digital and control circuits are not designed to be used for power supply.
1) Conductor
Conductors shall be solid, stranded or flexible plain or metal coated copper in accordance with Class 1, 2 or 5
of HD 383 ( equal to IEC 60228) in the range of 0.5 mm2 to 2.5 mm2 .
For multi-core cables the maximum conductor resistance shall be as HD 383 ( equal to IEC 60228) , and for
finished multi-pair, multi- triple and multi-quad cables the maximum resistance of HD 383 shall be increased
by 2 %.
Instrument Cables
102
The values are extracted from DIN VDE 0295 (equivalent with the international standard IEC 60228 and HD 383),
according to cross-sections and conductor classes, beginning with nominal cross-section of 0.5 mm2 .
Nominal
cross-section
mm2
0.5
0.75
1.0
1.5
2.5
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
a) PVC
b) Polyethylene
c) Polypropylene
d) Halogen free F.R
e) Cross-linked polyethylene
EN 50290-2-21
EN 50290-2-23
EN 50290-2-25
EN 50290-2-26
EN 50290-2-29
KCI
2 ) Insulation
The insulating material shall be selected from those
listed below.
Minimum thickness mm
Conductor size
Voltage rating
2
mm
0.5
0.75
1.0
1.5
2.5
90 V
0.2
0.2
0.26
0.3
-
300 V
0.26
0.26
0.26
0.35
-
500 V
0.44
0.44
0.44
0.44
0.53
3 ) Cable elements
The cable element is:
a single insulated wire, or
a pair consisting of two insulated conductors twisted together and designated wire a and wire b, or
a triple consisting of three insulated conductors twisted together and
designated wire a, wire b and wire c in order of rotation, or
a quad consisting of four insulated conductors twisted together and designated wire a, wire c,
wire b and wire d in order of rotation.
Wires a and b form pair 1 and wires c and d form pair 2.
Instrument Cables
The lay length of a pair, triple or quad shall not exceed 100 mm for cables with conductor
cross- sections 1.5 mm2, nor 150 mm for cables with conductor cross-section 2.5 mm2.
Core (Unit)
Pair (Unit)
Triple (Unit)
103
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
KCI
Instrument Cables
*** Optional : additional individual sheath over each screened element (ref. to other specs)
104
Laminated Sheath
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
Multi-layer sheath :
Aluminium copolymer bonded to
HDPE sheath + Polyamide layer
8 ) Metallic protection
When required by the relevant sectional specification the armouring shall consist of
one or more of the following:
8-1) layer of round or flat galvanised steel wires;
8-2) single or a double layer of steel or brass tapes;
8-3) galvanized steel or tinned copper wire braid.
Tape Armour
Braid Armour
9 ) Outer sheathing
The outer sheathing material shall be appropriate to the operating environment and may be
selected from the materials listed below :
a) PVC
EN 50290-2-22
b) Polyethylene
EN 50290-2-24
c) Halogen free F.R
EN 50290-2-27
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
Wire Armour
105
KCI
RE-Y(St)Y
EN 50288-7 (500 V)
RE-Y(St)Y Multi-Core
RE-Y(St)Y Multi-Pair
RE-Y(St)Y Multi-Triple
RE-Y(St)Y PiMF
RE-Y(St)Y TiMF
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-Y(St)Y
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+70 oC
Instrument Cables
108
PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.3
44
1000
3x0.5
0.6
0.9
6.6
54
1000
4x0.5
0.6
0.9
7.2
65
1000
5x0.5
0.6
0.9
7.8
76
1000
6x0.5
0.6
0.9
8.4
87
1000
7x0.5
0.6
0.9
8.4
96
1000
8x0.5
0.6
1.0
9.8
113
1000
10x0.5
0.6
1.0
10.7
134
1000
12x0.5
0.6
1.0
11.0
153
1000
16x0.5
0.6
1.0
12.2
193
1000
20x0.5
0.6
1.1
13.7
238
1000
24x0.5
0.6
1.1
15.1
280
1000
30x0.5
0.6
1.2
16.1
342
1000
2x0.75
0.6
0.9
6.7
52
1000
3x0.75
0.6
0.9
7.1
65
1000
4x0.75
0.6
0.9
7.7
79
1000
5x0.75
0.6
0.9
8.3
93
1000
6x0.75
0.6
0.9
9.0
108
1000
7x0.75
0.6
0.9
9.0
120
1000
8x0.75
0.6
1.0
10.6
141
1000
10x0.75
0.6
1.0
11.5
168
1000
12x0.75
0.6
1.0
11.9
193
1000
16x0.75
0.6
1.1
13.3
251
1000
20x0.75
0.6
1.1
14.8
305
1000
24x0.75
0.6
1.2
16.5
365
1000
30x0.75
0.6
1.2
17.5
440
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
109
KCI
RE-Y(St)Y
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
mm
Kg/Km
meter
0.6
0.9
7.1
59
1000
3x1
0.6
0.9
7.5
75
1000
4x1
0.6
0.9
8.1
92
1000
5x1
0.6
0.9
8.8
110
1000
6x1
0.6
1.0
9.8
131
1000
7x1
0.6
1.0
9.8
146
1000
8x1
0.6
1.0
11.3
167
1000
10x1
0.6
1.0
12.2
200
1000
12x1
0.6
1.0
12.6
232
1000
16x1
0.6
1.1
14.2
302
1000
20x1
0.6
1.1
15.8
368
1000
24x1
0.6
1.2
17.6
441
1000
30x1
0.6
1.2
18.6
534
1000
Instrument Cables
110
2x1.5
0.6
0.9
7.7
73
1000
3x1.5
0.6
0.9
8.1
96
1000
4x1.5
0.6
0.9
8.8
119
1000
5x1.5
0.6
1.0
9.8
146
1000
6x1.5
0.6
1.0
10.7
171
1000
7x1.5
0.6
1.0
10.7
191
1000
8x1.5
0.6
1.0
12.3
219
1000
10x1.5
0.6
1.1
13.6
270
1000
12x1.5
0.6
1.1
14.1
313
1000
16x1.5
0.6
1.1
15.6
402
1000
20x1.5
0.6
1.2
17.6
499
1000
24x1.5
0.6
1.3
19.6
599
1000
30x1.5
0.6
1.3
20.8
728
1000
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
8.9
102
1000
3x2.5
0.7
1.0
9.7
140
1000
4x2.5
0.7
1.0
10.5
175
1000
5x2.5
0.7
1.0
11.5
211
1000
6x2.5
0.7
1.1
12.7
253
1000
7x2.5
0.7
1.1
12.7
285
1000
8x2.5
0.7
1.1
14.8
326
1000
10x2.5
0.7
1.2
16.3
403
1000
12x2.5
0.7
1.2
16.9
470
1000
16x2.5
0.7
1.3
18.9
615
1000
20x2.5
0.7
1.3
21.1
754
1000
24x2.5
0.7
1.4
23.5
904
1000
30x2.5
0.7
1.5
25.1
1113
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
111
KCI
RE-Y(St)Y
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+70 oC
IEC 60332-1
Instrument Cables
Criteria
112
Black,Blue (Numbered)
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.3
44
1000
2x2x0.5
0.6
0.9
9.0
73
1000
3x2x0.5
0.6
1.0
9.7
96
1000
4x2x0.5
0.6
1.0
10.6
118
1000
5x2x0.5
0.6
1.0
11.6
140
1000
6x2x0.5
0.6
1.1
12.8
167
1000
7x2x0.5
0.6
1.1
12.8
185
1000
10x2x0.5
0.6
1.2
16.5
260
1000
12x2x0.5
0.6
1.2
17.0
298
1000
16x2x0.5
0.6
1.2
18.9
379
1000
20x2x0.5
0.6
1.3
21.2
469
1000
24x2x0.5
0.6
1.4
23.8
561
1000
30x2x0.5
0.6
1.4
25.2
676
500
1x2x0.75
0.6
0.9
6.7
52
1000
2x2x0.75
0.6
1.0
9.9
92
1000
3x2x0.75
0.6
1.0
10.5
118
1000
4x2x0.75
0.6
1.0
11.5
146
1000
5x2x0.75
0.6
1.1
12.7
180
1000
6x2x0.75
0.6
1.1
13.9
209
1000
7x2x0.75
0.6
1.1
13.9
233
1000
10x2x0.75
0.6
1.2
17.8
329
1000
12x2x0.75
0.6
1.2
18.4
380
1000
16x2x0.75
0.6
1.3
20.7
494
1000
20x2x0.75
0.6
1.4
23.3
612
1000
24x2x0.75
0.6
1.5
26.0
732
500
30x2x0.75
0.6
1.5
27.6
886
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
113
KCI
RE-Y(St)Y
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
mm
Kg/Km
meter
0.6
0.9
7.1
59
1000
2x2x1
0.6
1.0
10.5
106
1000
3x2x1
0.6
1.0
11.1
139
1000
4x2x1
0.6
1.0
12.2
173
1000
5x2x1
0.6
1.1
13.5
213
1000
6x2x1
0.6
1.1
14.7
249
1000
7x2x1
0.6
1.1
14.7
279
1000
10x2x1
0.6
1.2
19.0
395
1000
12x2x1
0.6
1.3
19.9
465
1000
16x2x1
0.6
1.3
22.1
597
1000
20x2x1
0.6
1.4
24.9
740
500
24x2x1
0.6
1.5
27.8
886
500
30x2x1
0.6
1.6
29.7
1088
500
Instrument Cables
114
1x2x1.5
0.6
0.9
7.7
74
1000
2x2x1.5
0.6
1.0
11.4
135
1000
3x2x1.5
0.6
1.0
12.2
180
1000
4x2x1.5
0.6
1.1
13.6
232
1000
5x2x1.5
0.6
1.1
14.8
280
1000
6x2x1.5
0.6
1.2
16.4
334
1000
7x2x1.5
0.6
1.2
16.4
376
1000
10x2x1.5
0.6
1.3
21.2
533
1000
12x2x1.5
0.6
1.3
21.9
621
1000
16x2x1.5
0.6
1.4
24.6
811
500
20x2x1.5
0.6
1.5
27.7
1006
500
24x2x1.5
0.6
1.6
30.9
1205
500
30x2x1.5
0.6
1.7
33.0
1481
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
8.9
103
1000
2x2x2.5
0.7
1.1
13.7
196
1000
3x2x2.5
0.7
1.1
14.6
266
1000
4x2x2.5
0.7
1.2
16.2
344
1000
5x2x2.5
0.7
1.2
17.8
417
1000
6x2x2.5
0.7
1.3
19.7
499
1000
7x2x2.5
0.7
1.3
19.7
564
1000
10x2x2.5
0.7
1.5
25.7
810
500
12x2x2.5
0.7
1.5
26.6
946
500
16x2x2.5
0.7
1.6
29.8
1237
500
20x2x2.5
0.7
1.7
33.5
1534
500
24x2x2.5
0.7
1.8
37.4
1836
500
30x2x2.5
0.7
1.9
39.9
2259
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
115
KCI
RE-Y(St)Y
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Outer Sheath
Extruded PVC
+70 oC
IEC 60332-1
Instrument Cables
Criteria
116
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.6
55
1000
2x3x0.5
0.6
1.0
10.1
98
1000
3x3x0.5
0.6
1.0
10.8
127
1000
4x3x0.5
0.6
1.0
11.8
158
1000
5x3x0.5
0.6
1.1
13.1
195
1000
6x3x0.5
0.6
1.1
14.3
227
1000
7x3x0.5
0.6
1.1
14.3
253
1000
10x3x0.5
0.6
1.2
18.4
359
1000
12x3x0.5
0.6
1.2
19.0
415
1000
16x3x0.5
0.6
1.3
21.3
541
1000
20x3x0.5
0.6
1.4
24.0
670
1000
24x3x0.5
0.6
1.5
26.8
802
500
30x3x0.5
0.6
1.5
28.4
971
500
1x3x0.75
0.6
0.9
7.1
66
1000
2x3x0.75
0.6
1.0
10.9
120
1000
3x3x0.75
0.6
1.0
11.6
159
1000
4x3x0.75
0.6
1.1
12.9
205
1000
5x3x0.75
0.6
1.1
14.1
246
1000
6x3x0.75
0.6
1.1
15.4
288
1000
7x3x0.75
0.6
1.1
15.4
324
1000
10x3x0.75
0.6
1.3
20.2
468
1000
12x3x0.75
0.6
1.3
20.8
543
1000
16x3x0.75
0.6
1.4
23.4
708
1000
20x3x0.75
0.6
1.5
26.3
878
500
24x3x0.75
0.6
1.6
29.4
1050
500
30x3x0.75
0.6
1.6
31.2
1277
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
117
KCI
RE-Y(St)Y
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
mm
Kg/Km
meter
0.6
0.9
7.5
76
1000
2x3x1
0.6
1.0
11.6
141
1000
3x3x1
0.6
1.0
12.3
189
1000
4x3x1
0.6
1.1
13.7
244
1000
5x3x1
0.6
1.1
15.0
295
1000
6x3x1
0.6
1.2
16.6
353
1000
7x3x1
0.6
1.2
16.6
398
1000
10x3x1
0.6
1.3
21.5
564
1000
12x3x1
0.6
1.3
22.2
658
1000
16x3x1
0.6
1.4
25.0
861
500
20x3x1
0.6
1.5
28.1
1068
500
24x3x1
0.6
1.6
31.4
1279
500
30x3x1
0.6
1.7
33.5
1574
500
Instrument Cables
118
1x3x1.5
0.6
0.9
8.1
97
1000
2x3x1.5
0.6
1.1
12.9
187
1000
3x3x1.5
0.6
1.1
13.7
254
1000
4x3x1.5
0.6
1.1
15.1
323
1000
5x3x1.5
0.6
1.2
16.8
399
1000
6x3x1.5
0.6
1.2
18.3
470
1000
7x3x1.5
0.6
1.2
18.3
532
1000
10x3x1.5
0.6
1.4
23.9
766
1000
12x3x1.5
0.6
1.4
24.8
896
500
16x3x1.5
0.6
1.5
27.8
1174
500
20x3x1.5
0.6
1.6
31.3
1458
500
24x3x1.5
0.6
1.7
35.0
1746
500
30x3x1.5
0.6
1.8
37.3
2152
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.7
1.0
9.7
141
1000
2x3x2.5
0.7
1.1
15.2
269
1000
3x3x2.5
0.7
1.2
16.4
378
1000
4x3x2.5
0.7
1.2
18.1
484
1000
5x3x2.5
0.7
1.3
20.1
599
1000
6x3x2.5
0.7
1.4
22.2
716
1000
7x3x2.5
0.7
1.4
22.2
813
1000
10x3x2.5
0.7
1.6
29.0
1167
500
12x3x2.5
0.7
1.6
30.0
1369
500
16x3x2.5
0.7
1.7
33.6
1795
500
20x3x2.5
0.7
1.9
38.0
2244
500
24x3x2.5
0.7
2.0
42.5
2685
500
30x3x2.5
0.7
2.1
45.3
3310
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
119
KCI
RE-Y(St)Y , PiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+70 oC
IEC 60332-1
Instrument Cables
Criteria
120
Black,Blue (Numbered)
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.6
54
1000
2x2x0.5
0.6
1.0
10.4
98
1000
3x2x0.5
0.6
1.0
11.0
126
1000
4x2x0.5
0.6
1.0
12.1
156
1000
5x2x0.5
0.6
1.1
13.4
192
1000
6x2x0.5
0.6
1.1
14.6
224
1000
7x2x0.5
0.6
1.1
14.6
250
1000
10x2x0.5
0.6
1.2
18.9
353
1000
12x2x0.5
0.6
1.3
19.8
416
1000
16x2x0.5
0.6
1.3
21.9
531
1000
20x2x0.5
0.6
1.4
24.7
657
500
24x2x0.5
0.6
1.5
27.6
787
500
30x2x0.5
0.6
1.6
29.5
963
500
1x2x0.75
0.6
0.9
7.1
62
1000
2x2x0.75
0.6
1.0
11.1
114
1000
3x2x0.75
0.6
1.0
11.9
149
1000
4x2x0.75
0.6
1.1
13.2
192
1000
5x2x0.75
0.6
1.1
14.4
230
1000
6x2x0.75
0.6
1.2
16.0
275
1000
7x2x0.75
0.6
1.2
16.0
307
1000
10x2x0.75
0.6
1.3
20.6
435
1000
12x2x0.75
0.6
1.3
21.3
503
1000
16x2x0.75
0.6
1.4
23.9
655
1000
20x2x0.75
0.6
1.5
26.9
810
500
24x2x0.75
0.6
1.6
30.1
970
500
30x2x0.75
0.6
1.6
31.9
1176
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
121
KCI
RE-Y(St)Y , PiMF
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
mm
Kg/Km
meter
0.6
0.9
7.4
70
1000
2x2x1
0.6
1.0
11.8
129
1000
3x2x1
0.6
1.0
12.5
171
1000
4x2x1
0.6
1.1
14.0
220
1000
5x2x1
0.6
1.1
15.3
265
1000
6x2x1
0.6
1.2
16.9
317
1000
7x2x1
0.6
1.2
16.9
355
1000
10x2x1
0.6
1.3
21.9
503
1000
12x2x1
0.6
1.4
22.8
593
1000
16x2x1
0.6
1.4
25.4
763
500
20x2x1
0.6
1.5
28.6
945
500
24x2x1
0.6
1.6
32.0
1132
500
30x2x1
0.6
1.7
34.1
1389
500
Instrument Cables
122
1x2x1.5
0.6
0.9
8.0
85
1000
2x2x1.5
0.6
1.1
13.0
164
1000
3x2x1.5
0.6
1.1
13.9
219
1000
4x2x1.5
0.6
1.1
15.3
277
1000
5x2x1.5
0.6
1.2
16.9
341
1000
6x2x1.5
0.6
1.2
18.5
400
1000
7x2x1.5
0.6
1.2
18.5
451
1000
10x2x1.5
0.6
1.4
24.2
650
1000
12x2x1.5
0.6
1.4
25.1
757
500
16x2x1.5
0.6
1.5
28.1
988
500
20x2x1.5
0.6
1.6
31.6
1225
500
24x2x1.5
0.6
1.8
35.6
1480
500
30x2x1.5
0.6
1.8
37.7
1802
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.7
1.0
9.5
118
1000
2x2x2.5
0.7
1.1
15.3
224
1000
3x2x2.5
0.7
1.2
16.5
311
1000
4x2x2.5
0.7
1.2
18.1
395
1000
5x2x2.5
0.7
1.3
20.1
487
1000
6x2x2.5
0.7
1.4
22.2
582
1000
7x2x2.5
0.7
1.4
22.2
657
1000
10x2x2.5
0.7
1.6
29.0
943
500
12x2x2.5
0.7
1.6
30.0
1101
500
16x2x2.5
0.7
1.7
33.7
1438
500
20x2x2.5
0.7
1.9
38.1
1797
500
24x2x2.5
0.7
2.0
42.6
2148
500
30x2x2.5
0.7
2.1
45.4
2639
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
123
KCI
RE-Y(St)Y , TiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+70 oC
Instrument Cables
124
PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
7.5x O.D
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
7.0
64
1000
2x3x0.5
0.6
1.0
11.5
120
1000
3x3x0.5
0.6
1.0
12.2
159
1000
4x3x0.5
0.6
1.1
13.6
204
1000
5x3x0.5
0.6
1.1
14.9
245
1000
6x3x0.5
0.6
1.2
16.5
293
1000
7x3x0.5
0.6
1.2
16.5
328
1000
10x3x0.5
0.6
1.3
21.3
464
1000
12x3x0.5
0.6
1.3
22.0
538
1000
16x3x0.5
0.6
1.4
24.7
701
500
20x3x0.5
0.6
1.5
27.8
868
500
24x3x0.5
0.6
1.6
31.1
1038
500
30x3x0.5
0.6
1.7
33.2
1273
500
1x3x0.75
0.6
0.9
7.4
76
1000
2x3x0.75
0.6
1.0
12.3
144
1000
3x3x0.75
0.6
1.1
13.3
197
1000
4x3x0.75
0.6
1.1
14.6
248
1000
5x3x0.75
0.6
1.2
16.3
305
1000
6x3x0.75
0.6
1.2
17.8
357
1000
7x3x0.75
0.6
1.2
17.8
402
1000
10x3x0.75
0.6
1.4
23.2
579
1000
12x3x0.75
0.6
1.4
24.0
673
1000
16x3x0.75
0.6
1.5
26.9
877
500
20x3x0.75
0.6
1.6
30.3
1087
500
24x3x0.75
0.6
1.7
33.8
1300
500
30x3x0.75
0.6
1.8
36.1
1596
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
125
KCI
RE-Y(St)Y , TiMF
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
mm
Kg/Km
meter
0.6
0.9
7.8
86
1000
2x3x1
0.6
1.1
13.3
170
1000
3x3x1
0.6
1.1
14.1
228
1000
4x3x1
0.6
1.1
15.5
288
1000
5x3x1
0.6
1.2
17.2
356
1000
6x3x1
0.6
1.2
18.9
418
1000
7x3x1
0.6
1.2
18.9
472
1000
10x3x1
0.6
1.4
24.6
679
500
12x3x1
0.6
1.4
25.5
792
500
16x3x1
0.6
1.5
28.6
1036
500
20x3x1
0.6
1.6
32.2
1285
500
24x3x1
0.6
1.8
36.2
1551
500
30x3x1
0.6
1.8
38.4
1891
500
Instrument Cables
126
1x3x1.5
0.6
0.9
8.5
108
1000
2x3x1.5
0.6
1.1
14.5
213
1000
3x3x1.5
0.6
1.1
15.4
290
1000
4x3x1.5
0.6
1.2
17.2
377
1000
5x3x1.5
0.6
1.2
18.9
457
1000
6x3x1.5
0.6
1.3
20.9
547
1000
7x3x1.5
0.6
1.3
20.9
619
1000
10x3x1.5
0.6
1.5
27.3
890
500
12x3x1.5
0.6
1.5
28.2
1040
500
16x3x1.5
0.6
1.6
31.7
1362
500
20x3x1.5
0.6
1.8
35.9
1704
500
24x3x1.5
0.6
1.9
40.1
2038
500
30x3x1.5
0.6
2.0
42.7
2507
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)Y , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Sheath thickness
mm2
Overall
Diameter
Insulation
thickness
EN 50288-7 (500 V)
0.7
1.0
10.0
154
1000
2x3x2.5
0.7
1.2
17.2
305
1000
3x3x2.5
0.7
1.2
18.4
419
1000
4x3x2.5
0.7
1.3
20.4
545
1000
5x3x2.5
0.7
1.4
22.7
674
1000
6x3x2.5
0.7
1.4
24.9
795
500
7x3x2.5
0.7
1.4
24.9
903
500
10x3x2.5
0.7
1.7
32.7
1309
500
12x3x2.5
0.7
1.7
33.9
1534
500
16x3x2.5
0.7
1.9
38.2
2024
500
20x3x2.5
0.7
2.0
43.0
2510
500
24x3x2.5
0.7
2.2
48.2
3020
500
30x3x2.5
0.7
2.3
51.4
3717
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
127
KCI
RE-2X(St)Y
Fire Resistant
EN 50288-7 (500 V)
RE-2X(St)Y Multi-Core
RE-2X(St)Y Multi-Pair
RE-2X(St)Y Multi-Triple
RE-2X(St)Y PiMF
RE-2X(St)Y TiMF
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
RE-2X(St)H
Fire Resistant
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-2X(St)Y
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
Conductor cross section
7.5 x O.D
IEC 60331
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
130
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.2
48
1000
3x0.5
0.6
0.9
7.7
58
1000
4x0.5
0.6
0.9
8.3
70
1000
5x0.5
0.6
0.9
9.1
82
1000
6x0.5
0.6
0.9
9.8
94
1000
7x0.5
0.6
0.9
9.8
104
1000
8x0.5
0.6
1.0
11.6
123
1000
10x0.5
0.6
1.0
12.6
146
1000
12x0.5
0.6
1.0
13.0
166
1000
16x0.5
0.6
1.1
14.6
214
1000
20x0.5
0.6
1.1
16.2
259
1000
24x0.5
0.6
1.2
18.2
310
1000
30x0.5
0.6
1.2
19.2
371
1000
2x0.75
0.6
0.9
7.7
55
1000
3x0.75
0.6
0.9
8.1
69
1000
4x0.75
0.6
0.9
8.8
84
1000
5x0.75
0.6
0.9
9.6
99
1000
6x0.75
0.6
1.0
10.7
119
1000
7x0.75
0.6
1.0
10.7
131
1000
8x0.75
0.6
1.0
12.3
150
1000
10x0.75
0.6
1.1
13.6
184
1000
12x0.75
0.6
1.1
14.1
211
1000
16x0.75
0.6
1.1
15.6
267
1000
20x0.75
0.6
1.2
17.6
330
1000
24x0.75
0.6
1.2
19.4
388
1000
30x0.75
0.6
1.3
20.8
475
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
131
KCI
RE-2X(St)Y
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
Kg/Km
meter
0.6
0.9
8.0
62
1000
3x1
0.6
0.9
8.5
79
1000
4x1
0.6
0.9
9.3
97
1000
5x1
0.6
1.0
10.3
119
1000
6x1
0.6
1.0
11.2
138
1000
7x1
0.6
1.0
11.2
153
1000
8x1
0.6
1.0
13.0
175
1000
10x1
0.6
1.1
14.4
216
1000
12x1
0.6
1.1
14.8
248
1000
16x1
0.6
1.1
16.4
316
1000
20x1
0.6
1.2
18.5
392
1000
24x1
0.6
1.2
20.5
462
1000
30x1
0.6
1.3
21.9
567
1000
Instrument Cables
132
2x1.5
0.6
0.9
8.6
76
1000
3x1.5
0.6
0.9
9.2
99
1000
4x1.5
0.6
1.0
10.2
127
1000
5x1.5
0.6
1.0
11.1
152
1000
6x1.5
0.6
1.0
12.1
176
1000
7x1.5
0.6
1.0
12.1
197
1000
8x1.5
0.6
1.1
14.3
231
1000
10x1.5
0.6
1.1
15.6
279
1000
12x1.5
0.6
1.1
16.1
323
1000
16x1.5
0.6
1.2
18.1
421
1000
20x1.5
0.6
1.2
20.1
514
1000
24x1.5
0.6
1.3
22.5
616
1000
30x1.5
0.6
1.4
24.0
757
1000
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
10.1
107
1000
3x2.5
0.7
1.0
10.7
141
1000
4x2.5
0.7
1.0
11.7
177
1000
5x2.5
0.7
1.1
13.0
218
1000
6x2.5
0.7
1.1
14.2
255
1000
7x2.5
0.7
1.1
14.2
287
1000
8x2.5
0.7
1.2
16.7
335
1000
10x2.5
0.7
1.2
18.2
406
1000
12x2.5
0.7
1.2
18.9
472
1000
16x2.5
0.7
1.3
21.2
617
1000
20x2.5
0.7
1.4
23.8
765
1000
24x2.5
0.7
1.5
26.6
916
500
30x2.5
0.7
1.5
28.2
1115
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
133
KCI
RE-2X(St)Y
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
Conductor cross section
Black,Blue (Numbered)
7.5 x O.D
IEC 60331
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
134
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.2
48
1000
2x2x0.5
0.6
1.0
10.8
83
1000
3x2x0.5
0.6
1.0
11.4
105
1000
4x2x0.5
0.6
1.0
12.5
128
1000
5x2x0.5
0.6
1.1
13.9
157
1000
6x2x0.5
0.6
1.1
15.2
181
1000
7x2x0.5
0.6
1.1
15.2
201
1000
10x2x0.5
0.6
1.2
19.6
283
1000
12x2x0.5
0.6
1.2
20.3
324
1000
16x2x0.5
0.6
1.3
22.8
419
1000
20x2x0.5
0.6
1.4
25.6
518
500
24x2x0.5
0.6
1.5
28.7
620
500
30x2x0.5
0.6
1.5
30.4
744
500
1x2x0.75
0.6
0.9
7.7
56
1000
2x2x0.75
0.6
1.0
11.4
98
1000
3x2x0.75
0.6
1.0
12.2
126
1000
4x2x0.75
0.6
1.1
13.6
161
1000
5x2x0.75
0.6
1.1
14.8
192
1000
6x2x0.75
0.6
1.1
16.2
223
1000
7x2x0.75
0.6
1.1
16.2
248
1000
10x2x0.75
0.6
1.3
21.2
358
1000
12x2x0.75
0.6
1.3
21.9
412
1000
16x2x0.75
0.6
1.4
24.6
534
500
20x2x0.75
0.6
1.4
27.5
650
500
24x2x0.75
0.6
1.5
30.7
778
500
30x2x0.75
0.6
1.6
32.8
952
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
135
KCI
RE-2X(St)Y
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
Kg/Km
meter
0.6
0.9
8.0
63
1000
2x2x1
0.6
1.0
12.0
112
1000
3x2x1
0.6
1.0
12.8
146
1000
4x2x1
0.6
1.1
14.3
187
1000
5x2x1
0.6
1.1
15.6
224
1000
6x2x1
0.6
1.1
17.1
261
1000
7x2x1
0.6
1.1
17.1
293
1000
10x2x1
0.6
1.3
22.4
422
1000
12x2x1
0.6
1.3
23.2
488
1000
16x2x1
0.6
1.4
26.0
635
500
20x2x1
0.6
1.5
29.2
786
500
24x2x1
0.6
1.6
32.7
940
500
30x2x1
0.6
1.6
34.7
1139
500
Instrument Cables
136
1x2x1.5
0.6
0.9
8.6
77
1000
2x2x1.5
0.6
1.0
13.0
140
1000
3x2x1.5
0.6
1.1
14.1
191
1000
4x2x1.5
0.6
1.1
15.5
240
1000
5x2x1.5
0.6
1.2
17.2
296
1000
6x2x1.5
0.6
1.2
18.8
346
1000
7x2x1.5
0.6
1.2
18.8
388
1000
10x2x1.5
0.6
1.4
24.5
559
500
12x2x1.5
0.6
1.4
25.4
649
500
16x2x1.5
0.6
1.5
28.5
846
500
20x2x1.5
0.6
1.6
32.1
1048
500
24x2x1.5
0.6
1.7
35.9
1253
500
30x2x1.5
0.6
1.8
38.3
1537
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
10.1
108
1000
2x2x2.5
0.7
1.1
15.2
199
1000
3x2x2.5
0.7
1.2
16.5
275
1000
4x2x2.5
0.7
1.2
18.1
347
1000
5x2x2.5
0.7
1.3
20.1
428
1000
6x2x2.5
0.7
1.3
22.0
503
1000
7x2x2.5
0.7
1.3
22.0
567
1000
10x2x2.5
0.7
1.5
28.8
815
500
12x2x2.5
0.7
1.6
30.0
962
500
16x2x2.5
0.7
1.7
33.7
1254
500
20x2x2.5
0.7
1.8
37.9
1553
500
24x2x2.5
0.7
1.9
42.4
1857
500
30x2x2.5
0.7
2.0
45.2
2280
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
137
KCI
RE-2X(St)Y
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
Instrument Cables
Criteria
Conductor cross section
7.5 x O.D
IEC 60331
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
138
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.7
59
1000
2x3x0.5
0.6
1.0
11.9
107
1000
3x3x0.5
0.6
1.0
12.7
138
1000
4x3x0.5
0.6
1.1
14.2
177
1000
5x3x0.5
0.6
1.1
15.5
211
1000
6x3x0.5
0.6
1.1
16.9
246
1000
7x3x0.5
0.6
1.1
16.9
275
1000
10x3x0.5
0.6
1.3
22.2
397
1000
12x3x0.5
0.6
1.3
22.9
459
1000
16x3x0.5
0.6
1.4
25.7
595
500
20x3x0.5
0.6
1.5
29.0
737
500
24x3x0.5
0.6
1.6
32.4
881
500
30x3x0.5
0.6
1.6
34.4
1065
500
1x3x0.75
0.6
0.9
8.1
70
1000
2x3x0.75
0.6
1.0
12.7
128
1000
3x3x0.75
0.6
1.1
13.7
174
1000
4x3x0.75
0.6
1.1
15.1
218
1000
5x3x0.75
0.6
1.1
16.6
262
1000
6x3x0.75
0.6
1.2
18.3
313
1000
7x3x0.75
0.6
1.2
18.3
351
1000
10x3x0.75
0.6
1.3
23.7
497
1000
12x3x0.75
0.6
1.4
24.8
586
500
16x3x0.75
0.6
1.5
27.8
762
500
20x3x0.75
0.6
1.5
31.1
931
500
24x3x0.75
0.6
1.7
35.0
1127
500
30x3x0.75
0.6
1.7
37.1
1367
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
139
KCI
RE-2X(St)Y
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
Kg/Km
meter
0.6
0.9
8.5
80
1000
2x3x1
0.6
1.0
13.4
148
1000
3x3x1
0.6
1.1
14.5
204
1000
4x3x1
0.6
1.1
15.9
256
1000
5x3x1
0.6
1.2
17.7
316
1000
6x3x1
0.6
1.2
19.3
370
1000
7x3x1
0.6
1.2
19.3
417
1000
10x3x1
0.6
1.4
25.3
600
500
12x3x1
0.6
1.4
26.2
698
500
16x3x1
0.6
1.5
29.4
911
500
20x3x1
0.6
1.6
33.1
1129
500
24x3x1
0.6
1.7
37.0
1351
500
30x3x1
0.6
1.8
39.5
1659
500
Instrument Cables
140
1x3x1.5
0.6
0.9
9.2
100
1000
2x3x1.5
0.6
1.1
14.7
194
1000
3x3x1.5
0.6
1.1
15.7
262
1000
4x3x1.5
0.6
1.2
17.5
340
1000
5x3x1.5
0.6
1.2
19.2
412
1000
6x3x1.5
0.6
1.3
21.2
492
1000
7x3x1.5
0.6
1.3
21.2
556
1000
10x3x1.5
0.6
1.5
27.7
799
500
12x3x1.5
0.6
1.5
28.7
932
500
16x3x1.5
0.6
1.6
32.2
1219
500
20x3x1.5
0.6
1.7
36.3
1511
500
24x3x1.5
0.6
1.8
40.5
1808
500
30x3x1.5
0.6
1.9
43.3
2225
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
10.7
143
1000
2x3x2.5
0.7
1.2
17.2
278
1000
3x3x2.5
0.7
1.2
18.4
381
1000
4x3x2.5
0.7
1.3
20.5
494
1000
5x3x2.5
0.7
1.3
22.5
602
1000
6x3x2.5
0.7
1.4
24.9
719
500
7x3x2.5
0.7
1.4
24.9
816
500
10x3x2.5
0.7
1.6
32.6
1171
500
12x3x2.5
0.7
1.7
33.9
1385
500
16x3x2.5
0.7
1.8
38.0
1812
500
20x3x2.5
0.7
1.9
42.8
2247
500
24x3x2.5
0.7
2.1
48.1
2706
500
30x3x2.5
0.7
2.2
51.3
3330
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
141
KCI
RE-2X(St)Y , PiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
Conductor cross section
Black,Blue (Numbered)
7.5 x O.D
IEC 60331
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
142
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.6
58
1000
2x2x0.5
0.6
1.0
12.1
106
1000
3x2x0.5
0.6
1.0
12.9
137
1000
4x2x0.5
0.6
1.1
14.4
175
1000
5x2x0.5
0.6
1.1
15.7
209
1000
6x2x0.5
0.6
1.2
17.4
250
1000
7x2x0.5
0.6
1.2
17.4
278
1000
10x2x0.5
0.6
1.3
22.5
392
1000
12x2x0.5
0.6
1.3
23.3
452
1000
16x2x0.5
0.6
1.4
26.2
587
500
20x2x0.5
0.6
1.5
29.4
725
500
24x2x0.5
0.6
1.6
32.9
867
500
30x2x0.5
0.6
1.6
34.9
1048
500
1x2x0.75
0.6
0.9
8.0
66
1000
2x2x0.75
0.6
1.0
12.8
122
1000
3x2x0.75
0.6
1.1
13.9
165
1000
4x2x0.75
0.6
1.1
15.3
205
1000
5x2x0.75
0.6
1.1
16.7
246
1000
6x2x0.75
0.6
1.2
18.5
294
1000
7x2x0.75
0.6
1.2
18.5
329
1000
10x2x0.75
0.6
1.4
24.2
474
1000
12x2x0.75
0.6
1.4
25.1
547
500
16x2x0.75
0.6
1.5
28.1
710
500
20x2x0.75
0.6
1.6
31.6
878
500
24x2x0.75
0.6
1.7
35.4
1049
500
30x2x0.75
0.6
1.7
37.5
1269
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
143
KCI
RE-2X(St)Y , PiMF
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
Kg/Km
meter
0.6
0.9
8.4
74
1000
2x2x1
0.6
1.1
13.7
142
1000
3x2x1
0.6
1.1
14.6
186
1000
4x2x1
0.6
1.1
16.0
233
1000
5x2x1
0.6
1.2
17.8
287
1000
6x2x1
0.6
1.2
19.5
335
1000
7x2x1
0.6
1.2
19.5
376
1000
10x2x1
0.6
1.4
25.5
541
500
12x2x1
0.6
1.4
26.4
627
500
16x2x1
0.6
1.5
29.6
816
500
20x2x1
0.6
1.6
33.3
1010
500
24x2x1
0.6
1.7
37.3
1208
500
30x2x1
0.6
1.8
39.8
1480
500
Instrument Cables
144
1x2x1.5
0.6
0.9
9.0
88
1000
2x2x1.5
0.6
1.1
14.8
172
1000
3x2x1.5
0.6
1.1
15.7
229
1000
4x2x1.5
0.6
1.2
17.5
295
1000
5x2x1.5
0.6
1.2
19.3
355
1000
6x2x1.5
0.6
1.3
21.3
425
1000
7x2x1.5
0.6
1.3
21.3
477
1000
10x2x1.5
0.6
1.5
27.8
686
500
12x2x1.5
0.6
1.5
28.8
797
500
16x2x1.5
0.6
1.6
32.3
1038
500
20x2x1.5
0.6
1.7
36.4
1286
500
24x2x1.5
0.6
1.8
40.7
1537
500
30x2x1.5
0.6
1.9
43.4
1886
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , PiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
10.4
121
1000
2x2x2.5
0.7
1.2
17.2
236
1000
3x2x2.5
0.7
1.2
18.3
317
1000
4x2x2.5
0.7
1.3
20.4
409
1000
5x2x2.5
0.7
1.3
22.4
495
1000
6x2x2.5
0.7
1.4
24.8
591
500
7x2x2.5
0.7
1.4
24.8
667
500
10x2x2.5
0.7
1.6
32.4
958
500
12x2x2.5
0.7
1.7
33.8
1128
500
16x2x2.5
0.7
1.8
37.9
1470
500
20x2x2.5
0.7
1.9
42.7
1820
500
24x2x2.5
0.7
2.1
47.9
2194
500
30x2x2.5
0.7
2.2
51.1
2689
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
145
KCI
RE-2X(St)Y , TiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Outer Sheath
+90 oC
Instrument Cables
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
7.5 x O.D
IEC 60331
Screened
Standard Values
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
146
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
8.0
70
1000
2x3x0.5
0.6
1.0
13.4
131
1000
3x3x0.5
0.6
1.1
14.5
178
1000
4x3x0.5
0.6
1.1
16.0
222
1000
5x3x0.5
0.6
1.2
17.7
273
1000
6x3x0.5
0.6
1.2
19.4
318
1000
7x3x0.5
0.6
1.2
19.4
356
1000
10x3x0.5
0.6
1.4
25.4
513
500
12x3x0.5
0.6
1.4
26.3
594
500
16x3x0.5
0.6
1.5
29.5
772
500
20x3x0.5
0.6
1.6
33.2
955
500
24x3x0.5
0.6
1.7
37.1
1142
500
30x3x0.5
0.6
1.8
39.6
1398
500
1x3x0.75
0.6
0.9
8.5
81
1000
2x3x0.75
0.6
1.1
14.5
159
1000
3x3x0.75
0.6
1.1
15.4
211
1000
4x3x0.75
0.6
1.2
17.2
271
1000
5x3x0.75
0.6
1.2
18.9
326
1000
6x3x0.75
0.6
1.3
20.9
389
1000
7x3x0.75
0.6
1.3
20.9
437
1000
10x3x0.75
0.6
1.4
27.1
618
500
12x3x0.75
0.6
1.5
28.2
728
500
16x3x0.75
0.6
1.6
31.7
947
500
20x3x0.75
0.6
1.7
35.7
1172
500
24x3x0.75
0.6
1.8
39.9
1401
500
30x3x0.75
0.6
1.9
42.5
1717
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
147
KCI
RE-2X(St)Y , TiMF
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
Kg/Km
meter
0.6
0.9
8.9
91
1000
2x3x1
0.6
1.1
15.2
180
1000
3x3x1
0.6
1.1
16.2
241
1000
4x3x1
0.6
1.2
18.1
311
1000
5x3x1
0.6
1.2
19.9
376
1000
6x3x1
0.6
1.3
22.0
449
1000
7x3x1
0.6
1.3
22.0
506
1000
10x3x1
0.6
1.5
28.7
727
500
12x3x1
0.6
1.5
29.8
846
500
16x3x1
0.6
1.6
33.4
1103
500
20x3x1
0.6
1.7
37.6
1366
500
24x3x1
0.6
1.8
42.1
1634
500
30x3x1
0.6
1.9
44.9
2006
500
Instrument Cables
148
1x3x1.5
0.6
0.9
9.5
112
1000
2x3x1.5
0.6
1.1
16.4
223
1000
3x3x1.5
0.6
1.2
17.7
308
1000
4x3x1.5
0.6
1.2
19.6
391
1000
5x3x1.5
0.6
1.3
21.7
483
1000
6x3x1.5
0.6
1.4
24.0
576
1000
7x3x1.5
0.6
1.4
24.0
651
1000
10x3x1.5
0.6
1.6
31.4
934
500
12x3x1.5
0.6
1.6
32.5
1090
500
16x3x1.5
0.6
1.7
36.4
1424
500
20x3x1.5
0.6
1.9
41.2
1779
500
24x3x1.5
0.6
2.0
46.1
2127
500
30x3x1.5
0.6
2.1
49.2
2612
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)Y , TiMF
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm2
Overall
Diameter
Sheath thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
11.1
156
1000
2x3x2.5
0.7
1.2
19.1
311
1000
3x3x2.5
0.7
1.3
20.7
433
1000
4x3x2.5
0.7
1.3
22.8
553
1000
5x3x2.5
0.7
1.4
25.3
682
500
6x3x2.5
0.7
1.5
28.0
815
500
7x3x2.5
0.7
1.5
28.0
923
500
10x3x2.5
0.7
1.8
36.8
1338
500
12x3x2.5
0.7
1.8
38.1
1563
500
16x3x2.5
0.7
1.9
42.8
2043
500
20x3x2.5
0.7
2.1
48.3
2550
500
24x3x2.5
0.7
2.3
54.3
3068
250
30x3x2.5
0.7
2.4
57.8
3769
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
149
KCI
RE-Y(St)YRY
EN 50288-7 (500 V)
RE-Y(St)YRY Multi-Core
RE-Y(St)YRY Multi-Pair
RE-Y(St)YRY Multi-Triple
RE-Y(St)YRY PiMF
RE-Y(St)YRY TiMF
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-Y(St)YRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
152
PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.5
1.3
10.9
229
1000
3x0.5
0.6
0.9
6.8
1.3
11.2
247
1000
4x0.5
0.6
0.9
7.4
1.3
11.8
271
1000
5x0.5
0.6
0.9
8.0
1.3
12.4
296
1000
6x0.5
0.6
0.9
8.6
1.4
13.2
327
1000
7x0.5
0.6
0.9
8.6
1.4
13.2
336
1000
8x0.5
0.6
0.9
9.8
1.4
14.4
379
1000
10x0.5
0.6
0.9
10.7
1.4
15.3
421
1000
12x0.5
0.6
0.9
11.0
1.4
15.6
447
1000
16x0.5
0.6
0.9
12.2
1.4
16.8
514
1000
20x0.5
0.6
0.9
13.5
1.5
18.3
591
1000
24x0.5
0.6
0.9
14.9
1.5
19.7
667
1000
30x0.5
0.6
1.25
15.7
1.5
21.2
866
1000
2x0.75
0.6
0.9
6.9
1.3
11.3
250
1000
3x0.75
0.6
0.9
7.3
1.3
11.7
271
1000
4x0.75
0.6
0.9
7.9
1.3
12.3
299
1000
5x0.75
0.6
0.9
8.5
1.4
13.1
333
1000
6x0.75
0.6
0.9
9.2
1.4
13.8
363
1000
7x0.75
0.6
0.9
9.2
1.4
13.8
375
1000
8x0.75
0.6
0.9
10.6
1.4
15.2
427
1000
10x0.75
0.6
0.9
11.5
1.4
16.1
476
1000
12x0.75
0.6
0.9
11.9
1.4
16.5
508
1000
16x0.75
0.6
0.9
13.1
1.5
17.9
597
1000
20x0.75
0.6
0.9
14.6
1.5
19.4
685
1000
24x0.75
0.6
1.25
16.1
1.6
21.8
910
1000
30x0.75
0.6
1.25
17.1
1.6
22.8
1012
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
153
KCI
RE-Y(St)YRY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
7.3
1.3
11.7
265
1000
3x1
0.6
0.9
7.7
1.3
12.1
288
1000
4x1
0.6
0.9
8.3
1.4
12.9
325
1000
5x1
0.6
0.9
9.0
1.4
13.6
358
1000
6x1
0.6
0.9
9.8
1.4
14.4
396
1000
7x1
0.6
0.9
9.8
1.4
14.4
411
1000
8x1
0.6
0.9
11.3
1.4
15.9
467
1000
10x1
0.6
0.9
12.2
1.4
16.8
522
1000
12x1
0.6
0.9
12.6
1.5
17.4
568
1000
16x1
0.6
0.9
14.0
1.5
18.8
668
1000
20x1
0.6
0.9
15.6
1.5
20.4
770
1000
24x1
0.6
1.25
17.2
1.6
22.9
1022
1000
30x1
0.6
1.25
18.2
1.6
23.9
1142
1000
Instrument Cables
154
2x1.5
0.6
0.9
7.9
1.3
12.3
293
1000
3x1.5
0.6
0.9
8.3
1.4
12.9
329
1000
4x1.5
0.6
0.9
9.0
1.4
13.6
373
1000
5x1.5
0.6
0.9
9.8
1.4
14.4
412
1000
6x1.5
0.6
0.9
10.7
1.4
15.3
457
1000
7x1.5
0.6
0.9
10.7
1.4
15.3
478
1000
8x1.5
0.6
0.9
12.3
1.5
17.1
549
1000
10x1.5
0.6
0.9
13.4
1.5
18.2
623
1000
12x1.5
0.6
0.9
13.9
1.5
18.7
674
1000
16x1.5
0.6
0.9
15.4
1.5
20.2
799
1000
20x1.5
0.6
1.25
17.2
1.6
22.9
1071
1000
24x1.5
0.6
1.25
19.0
1.6
24.7
1225
500
30x1.5
0.6
1.25
20.2
1.6
25.9
1391
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
9.1
1.4
13.7
356
1000
3x2.5
0.7
0.9
9.7
1.4
14.3
404
1000
4x2.5
0.7
0.9
10.5
1.4
15.1
456
1000
5x2.5
0.7
0.9
11.5
1.4
16.1
519
1000
6x2.5
0.7
0.9
12.5
1.5
17.3
585
1000
7x2.5
0.7
0.9
12.5
1.5
17.3
617
1000
8x2.5
0.7
0.9
14.6
1.5
19.4
708
1000
10x2.5
0.7
1.25
15.9
1.6
21.6
948
1000
12x2.5
0.7
1.25
16.5
1.6
22.2
1028
1000
16x2.5
0.7
1.25
18.3
1.6
24.0
1217
1000
20x2.5
0.7
1.25
20.5
1.7
26.4
1430
500
24x2.5
0.7
1.6
22.7
1.7
29.3
1820
500
30x2.5
0.7
1.6
24.1
1.8
30.9
2074
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
155
KCI
RE-Y(St)YRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
156
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.5
1.3
10.9
230
1000
2x2x0.5
0.6
0.9
9.2
1.4
13.8
327
1000
3x2x0.5
0.6
0.9
9.7
1.4
14.3
361
1000
4x2x0.5
0.6
0.9
10.6
1.4
15.2
404
1000
5x2x0.5
0.6
0.9
11.6
1.4
16.2
447
1000
6x2x0.5
0.6
0.9
12.6
1.5
17.4
499
1000
7x2x0.5
0.6
0.9
12.6
1.5
17.4
516
1000
10x2x0.5
0.6
1.25
16.1
1.5
21.6
796
1000
12x2x0.5
0.6
1.25
16.6
1.6
22.3
856
1000
16x2x0.5
0.6
1.25
18.5
1.6
24.2
999
1000
20x2x0.5
0.6
1.25
20.6
1.7
26.5
1155
500
24x2x0.5
0.6
1.6
23.0
1.7
29.6
1478
500
30x2x0.5
0.6
1.6
24.4
1.8
31.2
1663
500
1x2x0.75
0.6
0.9
6.9
1.3
11.3
251
1000
2x2x0.75
0.6
0.9
9.9
1.4
14.5
358
1000
3x2x0.75
0.6
0.9
10.5
1.4
15.1
398
1000
4x2x0.75
0.6
0.9
11.5
1.4
16.1
448
1000
5x2x0.75
0.6
0.9
12.5
1.5
17.3
511
1000
6x2x0.75
0.6
0.9
13.7
1.5
18.5
568
1000
7x2x0.75
0.6
0.9
13.7
1.5
18.5
592
1000
10x2x0.75
0.6
1.25
17.4
1.6
23.1
913
1000
12x2x0.75
0.6
1.25
18.0
1.6
23.7
988
1000
16x2x0.75
0.6
1.25
20.1
1.6
25.8
1147
500
20x2x0.75
0.6
1.6
22.5
1.7
29.1
1510
500
24x2x0.75
0.6
1.6
25.0
1.8
31.8
1731
500
30x2x0.75
0.6
1.6
26.6
1.8
33.4
1943
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
157
KCI
RE-Y(St)YRY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
7.3
1.3
11.7
265
1000
2x2x1
0.6
0.9
10.5
1.4
15.1
385
1000
3x2x1
0.6
0.9
11.1
1.4
15.7
433
1000
4x2x1
0.6
0.9
12.2
1.4
16.8
495
1000
5x2x1
0.6
0.9
13.3
1.5
18.1
565
1000
6x2x1
0.6
0.9
14.5
1.5
19.3
629
1000
7x2x1
0.6
0.9
14.5
1.5
19.3
659
1000
10x2x1
0.6
1.25
18.6
1.6
24.3
1015
1000
12x2x1
0.6
1.25
19.3
1.6
25.0
1093
500
16x2x1
0.6
1.25
21.5
1.7
27.4
1309
500
20x2x1
0.6
1.6
24.1
1.7
30.7
1697
500
24x2x1
0.6
1.6
26.8
1.8
33.6
1944
500
30x2x1
0.6
28.5
1.9
36.3
2469
500
Instrument Cables
158
1x2x1.5
0.6
0.9
7.9
1.3
12.3
294
1000
2x2x1.5
0.6
0.9
11.4
1.4
16.0
436
1000
3x2x1.5
0.6
0.9
12.2
1.4
16.8
501
1000
4x2x1.5
0.6
0.9
13.4
1.5
18.2
584
1000
5x2x1.5
0.6
0.9
14.6
1.5
19.4
661
1000
6x2x1.5
0.6
1.25
16.0
1.6
21.7
879
1000
7x2x1.5
0.6
1.25
16.0
1.6
21.7
921
1000
10x2x1.5
0.6
1.25
20.6
1.7
26.5
1220
500
12x2x1.5
0.6
1.25
21.3
1.7
27.2
1322
500
16x2x1.5
0.6
1.6
23.8
1.8
30.6
1779
500
20x2x1.5
0.6
1.6
26.7
1.8
33.5
2064
500
24x2x1.5
0.6
29.7
1.9
37.5
2646
500
30x2x1.5
0.6
31.6
2.0
39.6
3014
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
9.1
1.4
13.7
357
1000
2x2x2.5
0.7
0.9
13.5
1.5
18.3
550
1000
3x2x2.5
0.7
0.9
14.4
1.5
19.2
640
1000
4x2x2.5
0.7
1.25
15.8
1.6
21.5
878
1000
5x2x2.5
0.7
1.25
17.4
1.6
23.1
1001
1000
6x2x2.5
0.7
1.25
19.1
1.6
24.8
1126
500
7x2x2.5
0.7
1.25
19.1
1.6
24.8
1191
500
10x2x2.5
0.7
1.6
24.7
1.8
31.5
1791
500
12x2x2.5
0.7
1.6
25.6
1.8
32.4
1965
500
16x2x2.5
0.7
28.6
1.9
36.4
2620
500
20x2x2.5
0.7
32.5
2.0
40.5
3130
500
24x2x2.5
0.7
2.5
36.2
2.1
45.4
4011
500
30x2x2.5
0.7
2.5
38.5
2.2
47.9
4535
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
159
KCI
RE-Y(St)YRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC
+70 oC
IEC 60332-1
Instrument Cables
Criteria
160
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.8
1.3
11.2
247
1000
2x3x0.5
0.6
0.9
10.1
1.4
14.7
370
1000
3x3x0.5
0.6
0.9
10.8
1.4
15.4
414
1000
4x3x0.5
0.6
0.9
11.8
1.4
16.4
472
1000
5x3x0.5
0.6
0.9
12.9
1.5
17.7
533
1000
6x3x0.5
0.6
0.9
14.1
1.5
18.9
594
1000
7x3x0.5
0.6
0.9
14.1
1.5
18.9
620
1000
10x3x0.5
0.6
1.25
18.0
1.6
23.7
955
1000
12x3x0.5
0.6
1.25
18.6
1.6
24.3
1036
1000
16x3x0.5
0.6
1.25
20.7
1.7
26.6
1227
500
20x3x0.5
0.6
1.6
23.2
1.7
29.8
1605
500
24x3x0.5
0.6
1.6
25.8
1.8
32.6
1837
500
30x3x0.5
0.6
1.6
27.4
1.8
34.2
2066
500
1x3x0.75
0.6
0.9
7.3
1.3
11.7
272
1000
2x3x0.75
0.6
0.9
10.9
1.4
15.5
413
1000
3x3x0.75
0.6
0.9
11.6
1.4
16.2
467
1000
4x3x0.75
0.6
0.9
12.7
1.5
17.5
543
1000
5x3x0.75
0.6
0.9
13.9
1.5
18.7
613
1000
6x3x0.75
0.6
0.9
15.2
1.5
20.0
684
1000
7x3x0.75
0.6
0.9
15.2
1.5
20.0
719
1000
10x3x0.75
0.6
1.25
19.6
1.6
25.3
1107
500
12x3x0.75
0.6
1.25
20.2
1.6
25.9
1207
500
16x3x0.75
0.6
1.6
22.6
1.7
29.2
1624
500
20x3x0.75
0.6
1.6
25.3
1.8
32.1
1894
500
24x3x0.75
0.6
28.2
1.9
36.0
2431
500
30x3x0.75
0.6
30.0
1.9
37.8
2720
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
161
KCI
RE-Y(St)YRY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
7.7
1.3
12.1
289
1000
2x3x1
0.6
0.9
11.6
1.4
16.2
448
1000
3x3x1
0.6
0.9
12.3
1.4
16.9
511
1000
4x3x1
0.6
0.9
13.5
1.5
18.3
597
1000
5x3x1
0.6
0.9
14.8
1.5
19.6
682
1000
6x3x1
0.6
1.25
16.2
1.6
21.9
898
1000
7x3x1
0.6
1.25
16.2
1.6
21.9
943
1000
10x3x1
0.6
1.25
20.9
1.7
26.8
1252
500
12x3x1
0.6
1.6
21.6
1.7
28.2
1543
500
16x3x1
0.6
1.6
24.2
1.7
30.8
1818
500
20x3x1
0.6
1.6
27.1
1.8
33.9
2144
500
24x3x1
0.6
30.2
1.9
38.0
2722
500
30x3x1
0.6
32.1
1.9
39.9
3093
500
Instrument Cables
162
1x3x1.5
0.6
0.9
8.3
1.4
12.9
330
1000
2x3x1.5
0.6
0.9
12.7
1.5
17.5
525
1000
3x3x1.5
0.6
0.9
13.5
1.5
18.3
607
1000
4x3x1.5
0.6
0.9
14.9
1.5
19.7
711
1000
5x3x1.5
0.6
1.25
16.4
1.6
22.1
956
1000
6x3x1.5
0.6
1.25
17.9
1.6
23.6
1066
1000
7x3x1.5
0.6
1.25
17.9
1.6
23.6
1129
1000
10x3x1.5
0.6
1.6
23.1
1.7
29.7
1701
500
12x3x1.5
0.6
1.6
24.0
1.8
30.8
1865
500
16x3x1.5
0.6
1.6
26.8
1.8
33.6
2233
500
20x3x1.5
0.6
30.1
1.9
37.9
2901
500
24x3x1.5
0.6
34.0
2.0
42.0
3402
500
30x3x1.5
0.6
2.5
36.1
2.1
45.3
4325
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
9.7
1.4
14.3
406
1000
2x3x2.5
0.7
0.9
15.0
1.5
19.8
658
1000
3x3x2.5
0.7
1.25
16.0
1.6
21.7
923
1000
4x3x2.5
0.7
1.25
17.7
1.6
23.4
1080
1000
5x3x2.5
0.7
1.25
19.5
1.6
25.2
1238
500
6x3x2.5
0.7
1.25
21.4
1.7
27.3
1409
500
7x3x2.5
0.7
1.25
21.4
1.7
27.3
1507
500
10x3x2.5
0.7
27.8
1.9
35.6
2520
500
12x3x2.5
0.7
28.8
1.9
36.6
2753
500
16x3x2.5
0.7
32.6
2.0
40.6
3392
500
20x3x2.5
0.7
2.5
36.6
2.1
45.8
4408
500
24x3x2.5
0.7
2.5
40.9
2.2
50.3
5081
250
30x3x2.5
0.7
3.15
43.5
2.3
54.4
6505
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
163
KCI
RE-Y(St)YRY , PiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
164
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
6.8
1.3
11.2
247
1000
2x2x0.5
0.6
0.9
10.4
1.4
15.0
377
1000
3x2x0.5
0.6
0.9
11.0
1.4
15.6
420
1000
4x2x0.5
0.6
0.9
12.1
1.4
16.7
478
1000
5x2x0.5
0.6
0.9
13.2
1.5
18.0
538
1000
6x2x0.5
0.6
0.9
14.4
1.5
19.2
598
1000
7x2x0.5
0.6
0.9
14.4
1.5
19.2
624
1000
10x2x0.5
0.6
1.25
18.5
1.6
24.2
973
1000
12x2x0.5
0.6
1.25
19.2
1.6
24.9
1042
500
16x2x0.5
0.6
1.25
21.3
1.7
27.2
1231
500
20x2x0.5
0.6
1.6
23.9
1.7
30.5
1613
500
24x2x0.5
0.6
1.6
26.6
1.8
33.4
1844
500
30x2x0.5
0.6
28.3
1.9
36.1
2344
500
1x2x0.75
0.6
0.9
7.3
1.3
11.7
268
1000
2x2x0.75
0.6
0.9
11.1
1.4
15.7
409
1000
3x2x0.75
0.6
0.9
11.9
1.4
16.5
464
1000
4x2x0.75
0.6
0.9
13.0
1.5
17.8
537
1000
5x2x0.75
0.6
0.9
14.2
1.5
19.0
604
1000
6x2x0.75
0.6
0.9
15.6
1.5
20.4
671
1000
7x2x0.75
0.6
0.9
15.6
1.5
20.4
704
1000
10x2x0.75
0.6
1.25
20.0
1.6
25.7
1087
500
12x2x0.75
0.6
1.25
20.7
1.7
26.6
1190
500
16x2x0.75
0.6
1.6
23.1
1.7
29.7
1589
500
20x2x0.75
0.6
1.6
25.9
1.8
32.7
1847
500
24x2x0.75
0.6
28.9
1.9
36.7
2380
500
30x2x0.75
0.6
30.7
1.9
38.5
2648
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
165
KCI
RE-Y(St)YRY , PiMF
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
7.6
1.3
12.0
283
1000
2x2x1
0.6
0.9
11.8
1.4
16.4
443
1000
3x2x1
0.6
0.9
12.5
1.4
17.1
500
1000
4x2x1
0.6
0.9
13.8
1.5
18.6
580
1000
5x2x1
0.6
0.9
15.1
1.5
19.9
654
1000
6x2x1
0.6
1.25
16.5
1.6
22.2
874
1000
7x2x1
0.6
1.25
16.5
1.6
22.2
913
1000
10x2x1
0.6
1.25
21.3
1.7
27.2
1203
500
12x2x1
0.6
1.6
22.0
1.7
28.6
1488
500
16x2x1
0.6
1.6
24.6
1.8
31.4
1751
500
20x2x1
0.6
1.6
27.6
1.8
34.4
2041
500
24x2x1
0.6
30.8
1.9
38.6
2604
500
30x2x1
0.6
32.7
2.0
40.7
2954
500
Instrument Cables
166
1x2x1.5
0.6
0.9
8.2
1.4
12.8
318
1000
2x2x1.5
0.6
0.9
12.8
1.5
17.6
503
1000
3x2x1.5
0.6
0.9
13.7
1.5
18.5
579
1000
4x2x1.5
0.6
0.9
15.1
1.5
19.9
666
1000
5x2x1.5
0.6
1.25
16.5
1.6
22.2
899
1000
6x2x1.5
0.6
1.25
18.1
1.6
23.8
1008
1000
7x2x1.5
0.6
1.25
18.1
1.6
23.8
1059
1000
10x2x1.5
0.6
1.6
23.4
1.7
30.0
1586
500
12x2x1.5
0.6
1.6
24.3
1.8
31.1
1744
500
16x2x1.5
0.6
1.6
27.1
1.8
33.9
2065
500
20x2x1.5
0.6
30.4
1.9
38.2
2697
500
24x2x1.5
0.6
34.4
2.0
42.4
3152
500
30x2x1.5
0.6
2.5
36.5
2.1
45.7
3979
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
9.5
1.4
14.1
377
1000
2x2x2.5
0.7
0.9
15.1
1.5
19.9
614
1000
3x2x2.5
0.7
1.25
16.1
1.6
21.8
856
1000
4x2x2.5
0.7
1.25
17.7
1.6
23.4
991
1000
5x2x2.5
0.7
1.25
19.5
1.6
25.2
1127
500
6x2x2.5
0.7
1.25
21.4
1.7
27.3
1285
500
7x2x2.5
0.7
1.25
21.4
1.7
27.3
1361
500
10x2x2.5
0.7
27.8
1.9
35.6
2296
500
12x2x2.5
0.7
28.8
1.9
36.6
2486
500
16x2x2.5
0.7
32.7
2.0
40.7
3035
500
20x2x2.5
0.7
2.5
36.7
2.1
45.9
3961
500
24x2x2.5
0.7
2.5
41.0
2.2
50.4
4546
250
30x2x2.5
0.7
3.15
43.6
2.3
54.5
5835
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
167
KCI
RE-Y(St)YRY , TiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
Instrument Cables
+70 oC
PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
168
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
7.2
1.3
11.6
264
1000
2x3x0.5
0.6
0.9
11.5
1.4
16.1
427
1000
3x3x0.5
0.6
0.9
12.2
1.4
16.8
481
1000
4x3x0.5
0.6
0.9
13.4
1.5
18.2
556
1000
5x3x0.5
0.6
0.9
14.7
1.5
19.5
626
1000
6x3x0.5
0.6
1.25
16.1
1.5
21.6
828
1000
7x3x0.5
0.6
1.25
16.1
1.5
21.6
863
1000
10x3x0.5
0.6
1.25
20.7
1.7
26.6
1150
500
12x3x0.5
0.6
1.25
21.4
1.7
27.3
1239
500
16x3x0.5
0.6
1.6
23.9
1.7
30.5
1656
500
20x3x0.5
0.6
1.6
26.8
1.8
33.6
1926
500
24x3x0.5
0.6
29.9
1.9
37.7
2480
500
30x3x0.5
0.6
31.8
1.9
39.6
2791
500
1x3x0.75
0.6
0.9
7.6
1.3
12.0
289
1000
2x3x0.75
0.6
0.9
12.3
1.4
16.9
467
1000
3x3x0.75
0.6
0.9
13.1
1.5
17.9
543
1000
4x3x0.75
0.6
0.9
14.4
1.5
19.2
622
1000
5x3x0.75
0.6
1.25
15.9
1.5
21.4
830
1000
6x3x0.75
0.6
1.25
17.4
1.6
23.1
940
1000
7x3x0.75
0.6
1.25
17.4
1.6
23.1
985
1000
10x3x0.75
0.6
1.6
22.4
1.7
29.0
1477
500
12x3x0.75
0.6
1.6
23.2
1.7
29.8
1608
500
16x3x0.75
0.6
1.6
25.9
1.8
32.7
1914
500
20x3x0.75
0.6
29.1
1.9
36.9
2498
500
24x3x0.75
0.6
32.8
2.0
40.8
2897
500
30x3x0.75
0.6
2.5
34.9
2.1
44.1
3681
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
169
KCI
RE-Y(St)YRY , TiMF
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
8.0
1.3
12.4
307
1000
2x3x1
0.6
0.9
13.1
1.5
17.9
515
1000
3x3x1
0.6
0.9
13.9
1.5
18.7
594
1000
4x3x1
0.6
0.9
15.3
1.5
20.1
684
1000
5x3x1
0.6
1.25
16.8
1.6
22.5
925
1000
6x3x1
0.6
1.25
18.5
1.6
24.2
1028
1000
7x3x1
0.6
1.25
18.5
1.6
24.2
1082
1000
10x3x1
0.6
1.6
23.8
1.7
30.4
1635
500
12x3x1
0.6
1.6
24.7
1.8
31.5
1782
500
16x3x1
0.6
1.6
27.6
1.8
34.4
2132
500
20x3x1
0.6
31.0
1.9
38.8
2784
500
24x3x1
0.6
2.5
35.0
2.0
44.0
3619
500
30x3x1
0.6
2.5
37.2
2.1
46.4
4112
500
Instrument Cables
170
1x3x1.5
0.6
0.9
8.7
1.4
13.3
349
1000
2x3x1.5
0.6
0.9
14.3
1.5
19.1
587
1000
3x3x1.5
0.6
0.9
15.2
1.5
20.0
686
1000
4x3x1.5
0.6
1.25
16.8
1.6
22.5
946
1000
5x3x1.5
0.6
1.25
18.5
1.6
24.2
1078
1000
6x3x1.5
0.6
1.25
20.3
1.7
26.2
1221
500
7x3x1.5
0.6
1.25
20.3
1.7
26.2
1294
500
10x3x1.5
0.6
1.6
26.3
1.8
33.1
1929
500
12x3x1.5
0.6
1.6
27.2
1.8
34.0
2118
500
16x3x1.5
0.6
30.5
1.9
38.3
2834
500
20x3x1.5
0.6
2.5
34.7
2.1
43.9
3787
500
24x3x1.5
0.6
2.5
38.7
2.1
47.9
4335
500
30x3x1.5
0.6
2.5
41.1
2.2
50.5
4905
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
10.0
1.4
14.6
426
1000
2x3x2.5
0.7
1.25
16.8
1.6
22.5
875
1000
3x3x2.5
0.7
1.25
18.0
1.6
23.7
1017
1000
4x3x2.5
0.7
1.25
19.8
1.7
25.7
1208
500
5x3x2.5
0.7
1.6
21.9
1.7
28.5
1553
500
6x3x2.5
0.7
1.6
24.1
1.8
30.9
1765
500
7x3x2.5
0.7
1.6
24.1
1.8
30.9
1873
500
10x3x2.5
0.7
31.3
2.0
39.3
2815
500
12x3x2.5
0.7
32.9
2.0
40.9
3132
500
16x3x2.5
0.7
2.5
36.8
2.1
46.0
4189
500
20x3x2.5
0.7
2.5
41.4
2.2
50.8
4950
250
24x3x2.5
0.7
3.15
46.6
2.4
57.7
6477
250
30x3x2.5
0.7
3.15
49.6
2.5
60.9
7328
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
171
KCI
RE-Y(St)YRY , PiMFY
EN 50288-7 (500 V)
RE-Y(St)YRY TiMFY
RE-2X(St)HRH , PiMFH
RE-2X(St)HRH TiMFH
KCI
RE-Y(St)YRY , PiMFY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Individual Element
Jacket
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
174
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Each Screened Pair has individual PVC Jacket
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , PiMFY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
7.8
1.4
12.4
288
1000
2x2x0.5
0.6
0.9
12.2
1.5
17.0
444
1000
3x2x0.5
0.6
0.9
13.0
1.5
17.8
492
1000
4x2x0.5
0.6
0.9
14.2
1.5
19.0
562
1000
5x2x0.5
0.6
1.25
15.6
1.6
21.3
764
1000
6x2x0.5
0.6
1.25
17.1
1.6
22.8
840
1000
7x2x0.5
0.6
1.25
17.1
1.6
22.8
870
1000
10x2x0.5
0.6
1.6
22.1
1.7
28.7
1327
500
12x2x0.5
0.6
1.6
22.9
1.7
29.5
1412
500
16x2x0.5
0.6
1.6
25.5
1.8
32.3
1658
500
20x2x0.5
0.6
28.6
1.9
36.4
2173
500
24x2x0.5
0.6
32.3
2.0
40.3
2538
500
30x2x0.5
0.6
34.4
2.0
42.4
2821
500
1x2x0.75
0.6
0.9
8.3
1.4
12.9
305
1000
2x2x0.75
0.6
0.9
12.9
1.5
17.7
476
1000
3x2x0.75
0.6
0.9
13.8
1.5
18.6
538
1000
4x2x0.75
0.6
0.9
15.2
1.5
20.0
616
1000
5x2x0.75
0.6
1.25
16.6
1.6
22.3
830
1000
6x2x0.75
0.6
1.25
18.2
1.6
23.9
925
1000
7x2x0.75
0.6
1.25
18.2
1.6
23.9
962
1000
10x2x0.75
0.6
1.6
23.6
1.8
30.4
1459
500
12x2x0.75
0.6
1.6
24.4
1.8
31.2
1575
500
16x2x0.75
0.6
1.6
27.3
1.9
34.3
1853
500
20x2x0.75
0.6
30.6
2.0
38.6
2429
500
24x2x0.75
0.6
34.6
2.0
42.6
2812
500
30x2x0.75
0.6
2.5
36.8
2.1
46.0
3553
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
175
KCI
RE-Y(St)YRY , PiMFY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
8.6
1.4
13.2
320
1000
2x2x1
0.6
0.9
13.6
1.5
18.4
506
1000
3x2x1
0.6
0.9
14.5
1.5
19.3
575
1000
4x2x1
0.6
1.25
15.9
1.6
21.6
800
1000
5x2x1
0.6
1.25
17.5
1.6
23.2
891
1000
6x2x1
0.6
1.25
19.2
1.6
24.9
994
500
7x2x1
0.6
1.25
19.2
1.6
24.9
1037
500
10x2x1
0.6
1.6
24.8
1.8
31.6
1588
500
12x2x1
0.6
1.6
25.7
1.8
32.5
1701
500
16x2x1
0.6
28.8
1.9
36.6
2269
500
20x2x1
0.6
32.7
2.0
40.7
2691
500
24x2x1
0.6
2.5
36.5
2.1
45.7
3484
500
30x2x1
0.6
2.5
38.8
2.2
48.2
3916
500
Instrument Cables
176
1x2x1.5
0.6
0.9
9.2
1.4
13.8
350
1000
2x2x1.5
0.6
0.9
14.6
1.5
19.4
565
1000
3x2x1.5
0.6
1.25
15.6
1.6
21.3
783
1000
4x2x1.5
0.6
1.25
17.2
1.6
22.9
898
1000
5x2x1.5
0.6
1.25
18.9
1.6
24.6
1014
500
6x2x1.5
0.6
1.25
20.8
1.7
26.7
1142
500
7x2x1.5
0.6
1.25
20.8
1.7
26.7
1198
500
10x2x1.5
0.6
1.6
27.0
1.8
33.8
1811
500
12x2x1.5
0.6
28.0
1.9
35.8
2217
500
16x2x1.5
0.6
31.3
2.0
39.3
2628
500
20x2x1.5
0.6
2.5
35.6
2.1
44.8
3519
500
24x2x1.5
0.6
2.5
39.7
2.2
49.1
4023
500
30x2x1.5
0.6
2.5
42.2
2.3
51.8
4538
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , PiMFY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
10.5
1.4
15.1
410
1000
2x2x2.5
0.7
1.25
16.8
1.6
22.5
823
1000
3x2x2.5
0.7
1.25
18.0
1.6
23.7
938
1000
4x2x2.5
0.7
1.25
19.9
1.7
25.8
1102
500
5x2x2.5
0.7
1.6
21.9
1.7
28.5
1420
500
6x2x2.5
0.7
1.6
24.1
1.8
30.9
1606
500
7x2x2.5
0.7
1.6
24.1
1.8
30.9
1687
500
10x2x2.5
0.7
31.8
2.0
39.8
2607
500
12x2x2.5
0.7
32.9
2.0
40.9
2838
500
16x2x2.5
0.7
2.5
36.9
2.1
46.1
3760
500
20x2x2.5
0.7
2.5
41.4
2.3
51.0
4435
250
24x2x2.5
0.7
3.15
46.7
2.4
57.8
5835
250
30x2x2.5
0.7
3.15
49.7
2.5
61.0
6523
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
177
KCI
RE-Y(St)YRY , TiMFY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Individual Element
Jacket
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
Instrument Cables
+70 oC
178
PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Each Screened Triple has individual PVC Jacket
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , TiMFY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
8.2
1.4
12.8
306
1000
2x3x0.5
0.6
0.9
13.4
1.5
18.2
496
1000
3x3x0.5
0.6
0.9
14.2
1.5
19.0
561
1000
4x3x0.5
0.6
1.25
15.7
1.6
21.4
772
1000
5x3x0.5
0.6
1.25
17.2
1.6
22.9
869
1000
6x3x0.5
0.6
1.25
18.9
1.6
24.6
967
500
7x3x0.5
0.6
1.25
18.9
1.6
24.6
1006
500
10x3x0.5
0.6
1.6
24.4
1.8
31.2
1527
500
12x3x0.5
0.6
1.6
25.3
1.8
32.1
1649
500
16x3x0.5
0.6
28.3
1.9
36.1
2201
500
20x3x0.5
0.6
32.2
2.0
40.2
2579
500
24x3x0.5
0.6
2.5
35.9
2.1
45.1
3341
500
30x3x0.5
0.6
2.5
38.2
2.2
47.6
3748
500
1x3x0.75
0.6
0.9
8.6
1.4
13.2
326
1000
2x3x0.75
0.6
0.9
14.2
1.5
19.0
542
1000
3x3x0.75
0.6
0.9
15.2
1.5
20.0
617
1000
4x3x0.75
0.6
1.25
16.7
1.6
22.4
844
1000
5x3x0.75
0.6
1.25
18.4
1.6
24.1
953
1000
6x3x0.75
0.6
1.25
20.2
1.7
26.1
1083
500
7x3x0.75
0.6
1.25
20.2
1.7
26.1
1132
500
10x3x0.75
0.6
1.6
26.1
1.8
32.9
1698
500
12x3x0.75
0.6
1.6
27.1
1.8
33.9
1841
500
16x3x0.75
0.6
30.3
1.9
38.1
2464
500
20x3x0.75
0.6
34.5
2.0
42.5
2915
500
24x3x0.75
0.6
2.5
38.5
2.2
47.9
3759
500
30x3x0.75
0.6
2.5
40.9
2.2
50.3
4210
250
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
179
KCI
RE-Y(St)YRY , TiMFY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
9.0
1.4
13.6
350
1000
2x3x1
0.6
0.9
14.9
1.5
19.7
578
1000
3x3x1
0.6
1.25
16.0
1.6
21.7
804
1000
4x3x1
0.6
1.25
17.6
1.6
23.3
912
1000
5x3x1
0.6
1.25
19.4
1.6
25.1
1041
500
6x3x1
0.6
1.25
21.3
1.7
27.2
1173
500
7x3x1
0.6
1.25
21.3
1.7
27.2
1231
500
10x3x1
0.6
1.6
27.6
1.8
34.4
1860
500
12x3x1
0.6
28.6
1.9
36.4
2282
500
16x3x1
0.6
32.4
2.0
40.4
2764
500
20x3x1
0.6
2.5
36.4
2.1
45.6
3623
500
24x3x1
0.6
2.5
40.7
2.2
50.1
4140
250
30x3x1
0.6
2.5
43.2
2.3
52.8
4672
250
Instrument Cables
180
1x3x1.5
0.6
0.9
9.7
1.4
14.3
387
1000
2x3x1.5
0.6
1.25
16.2
1.6
21.9
787
1000
3x3x1.5
0.6
1.25
17.3
1.6
23.0
907
1000
4x3x1.5
0.6
1.25
19.1
1.6
24.8
1046
500
5x3x1.5
0.6
1.25
21.0
1.7
26.9
1207
500
6x3x1.5
0.6
1.6
23.1
1.8
29.9
1553
500
7x3x1.5
0.6
1.6
23.1
1.8
29.9
1631
500
10x3x1.5
0.6
30.0
1.9
37.8
2425
500
12x3x1.5
0.6
31.1
2.0
39.1
2662
500
16x3x1.5
0.6
2.5
35.3
2.1
44.5
3637
500
20x3x1.5
0.6
2.5
39.7
2.2
49.1
4231
500
24x3x1.5
0.6
3.15
44.7
2.4
55.8
5582
250
30x3x1.5
0.6
3.15
47.5
2.4
58.6
6222
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YRY , TiMFY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
11.0
1.4
15.6
459
1000
2x3x2.5
0.7
1.25
18.7
1.6
24.4
952
1000
3x3x2.5
0.7
1.25
20.0
1.7
25.9
1122
500
4x3x2.5
0.7
1.6
22.1
1.7
28.7
1491
500
5x3x2.5
0.7
1.6
24.4
1.8
31.2
1712
500
6x3x2.5
0.7
1.6
26.9
1.8
33.7
1923
500
7x3x2.5
0.7
1.6
26.9
1.8
33.7
2037
500
10x3x2.5
0.7
2.5
35.5
2.1
44.7
3547
500
12x3x2.5
0.7
2.5
36.8
2.1
46.0
3835
500
16x3x2.5
0.7
2.5
41.2
2.2
50.6
4620
250
20x3x2.5
0.7
3.15
46.8
2.4
57.9
6178
250
24x3x2.5
0.7
3.15
52.2
2.5
63.5
7074
250
30x3x2.5
0.7
3.15
56.0
2.6
67.5
8093
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
181
KCI
RE-2X(St)YRY
Fire Resistant
EN 50288-7 (500 V)
RE-2X(St)YRY Multi-Core
RE-2X(St)YRY Multi-Pair
RE-2X(St)YRY Multi-Triple
RE-2X(St)YRY PiMF
RE-2X(St)YRY TiMF
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
RE-2X(St)HRH
Fire Resistant
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-2X(St)YRY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
184
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.4
1.3
11.8
254
1000
3x0.5
0.6
0.9
7.9
1.3
12.3
277
1000
4x0.5
0.6
0.9
8.5
1.3
12.9
304
1000
5x0.5
0.6
0.9
9.3
1.4
13.9
336
1000
6x0.5
0.6
0.9
10.0
1.4
14.6
369
1000
7x0.5
0.6
0.9
10.0
1.4
14.6
378
1000
8x0.5
0.6
0.9
11.6
1.4
16.2
429
1000
10x0.5
0.6
0.9
12.6
1.4
17.2
474
1000
12x0.5
0.6
0.9
13.0
1.4
17.6
507
1000
16x0.5
0.6
0.9
14.4
1.5
19.2
587
1000
20x0.5
0.6
1.25
16.0
1.5
21.5
799
1000
24x0.5
0.6
1.25
17.8
1.6
23.5
903
1000
30x0.5
0.6
1.25
18.8
1.6
24.5
991
500
2x0.75
0.6
0.9
7.9
1.3
12.3
275
1000
3x0.75
0.6
0.9
8.3
1.3
12.7
296
1000
4x0.75
0.6
0.9
9.0
1.4
13.6
337
1000
5x0.75
0.6
0.9
9.8
1.4
14.4
368
1000
6x0.75
0.6
0.9
10.7
1.4
15.3
404
1000
7x0.75
0.6
0.9
10.7
1.4
15.3
416
1000
8x0.75
0.6
0.9
12.3
1.4
16.9
472
1000
10x0.75
0.6
0.9
13.4
1.5
18.2
536
1000
12x0.75
0.6
0.9
13.9
1.5
18.7
570
1000
16x0.75
0.6
0.9
15.4
1.5
20.2
661
1000
20x0.75
0.6
1.25
17.2
1.6
22.9
900
1000
24x0.75
0.6
1.25
19.0
1.6
24.7
1020
500
30x0.75
0.6
1.25
20.2
1.6
25.9
1136
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
185
KCI
RE-2X(St)YRY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
8.2
1.3
12.6
289
1000
3x1
0.6
0.9
8.7
1.4
13.3
319
1000
4x1
0.6
0.9
9.5
1.4
14.1
358
1000
5x1
0.6
0.9
10.3
1.4
14.9
397
1000
6x1
0.6
0.9
11.2
1.4
15.8
437
1000
7x1
0.6
0.9
11.2
1.4
15.8
452
1000
8x1
0.6
0.9
13.0
1.4
17.6
511
1000
10x1
0.6
0.9
14.2
1.5
19.0
582
1000
12x1
0.6
0.9
14.6
1.5
19.4
628
1000
16x1
0.6
1.25
16.2
1.5
21.7
857
1000
20x1
0.6
1.25
18.1
1.6
23.8
997
1000
24x1
0.6
1.25
20.1
1.6
25.8
1120
500
30x1
0.6
1.25
21.3
1.6
27.0
1255
500
Instrument Cables
186
2x1.5
0.6
0.9
8.8
1.4
13.4
323
1000
3x1.5
0.6
0.9
9.4
1.4
14.0
359
1000
4x1.5
0.6
0.9
10.2
1.4
14.8
399
1000
5x1.5
0.6
0.9
11.1
1.4
15.7
445
1000
6x1.5
0.6
0.9
12.1
1.4
16.7
497
1000
7x1.5
0.6
0.9
12.1
1.4
16.7
518
1000
8x1.5
0.6
0.9
14.1
1.5
18.9
597
1000
10x1.5
0.6
0.9
15.4
1.5
20.2
674
1000
12x1.5
0.6
1.25
15.9
1.5
21.4
853
1000
16x1.5
0.6
1.25
17.7
1.6
23.4
1014
1000
20x1.5
0.6
1.25
19.7
1.6
25.4
1161
500
24x1.5
0.6
1.6
21.9
1.7
28.5
1501
500
30x1.5
0.6
1.6
23.2
1.7
29.8
1692
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.9
10.1
1.4
14.7
379
1000
3x2.5
0.7
0.9
10.7
1.4
15.3
427
1000
4x2.5
0.7
0.9
11.7
1.4
16.3
485
1000
5x2.5
0.7
0.9
12.8
1.5
17.6
556
1000
6x2.5
0.7
0.9
14.0
1.5
18.8
621
1000
7x2.5
0.7
0.9
14.0
1.5
18.8
653
1000
8x2.5
0.7
1.25
16.3
1.5
21.8
872
1000
10x2.5
0.7
1.25
17.8
1.6
23.5
1001
1000
12x2.5
0.7
1.25
18.5
1.6
24.2
1092
1000
16x2.5
0.7
1.25
20.6
1.6
26.3
1282
500
20x2.5
0.7
1.6
23.0
1.7
29.6
1682
500
24x2.5
0.7
1.6
25.6
1.8
32.4
1934
500
30x2.5
0.7
1.6
27.2
1.8
34.0
2192
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
187
KCI
RE-2X(St)YRY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
188
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.4
1.3
11.8
254
1000
2x2x0.5
0.6
0.9
10.8
1.4
15.4
368
1000
3x2x0.5
0.6
0.9
11.4
1.4
16.0
405
1000
4x2x0.5
0.6
0.9
12.5
1.4
17.1
456
1000
5x2x0.5
0.6
0.9
13.7
1.5
18.5
515
1000
6x2x0.5
0.6
0.9
15.0
1.5
19.8
568
1000
7x2x0.5
0.6
0.9
15.0
1.5
19.8
587
1000
10x2x0.5
0.6
1.25
19.2
1.6
24.9
915
500
12x2x0.5
0.6
1.25
19.9
1.6
25.6
981
500
16x2x0.5
0.6
1.6
22.2
1.7
28.8
1322
500
20x2x0.5
0.6
1.6
24.8
1.7
31.4
1510
500
24x2x0.5
0.6
1.6
27.7
1.8
34.5
1713
500
30x2x0.5
0.6
29.4
1.8
37.0
2152
500
1x2x0.75
0.6
0.9
7.9
1.3
12.3
275
1000
2x2x0.75
0.6
0.9
11.4
1.4
16.0
399
1000
3x2x0.75
0.6
0.9
12.2
1.4
16.8
447
1000
4x2x0.75
0.6
0.9
13.4
1.5
18.2
512
1000
5x2x0.75
0.6
0.9
14.6
1.5
19.4
571
1000
6x2x0.75
0.6
1.25
16.0
1.5
21.5
763
1000
7x2x0.75
0.6
1.25
16.0
1.5
21.5
788
1000
10x2x0.75
0.6
1.25
20.6
1.6
26.3
1032
500
12x2x0.75
0.6
1.25
21.3
1.6
27.0
1101
500
16x2x0.75
0.6
1.6
23.8
1.7
30.4
1488
500
20x2x0.75
0.6
1.6
26.7
1.8
33.5
1716
500
24x2x0.75
0.6
29.7
1.9
37.5
2228
500
30x2x0.75
0.6
31.6
1.9
39.4
2479
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
189
KCI
RE-2X(St)YRY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
8.2
1.3
12.6
289
1000
2x2x1
0.6
0.9
12.0
1.4
16.6
426
1000
3x2x1
0.6
0.9
12.8
1.4
17.4
481
1000
4x2x1
0.6
0.9
14.1
1.5
18.9
553
1000
5x2x1
0.6
0.9
15.4
1.5
20.2
624
1000
6x2x1
0.6
1.25
16.9
1.5
22.4
827
1000
7x2x1
0.6
1.25
16.9
1.5
22.4
858
1000
10x2x1
0.6
1.6
21.8
1.7
28.4
1306
500
12x2x1
0.6
1.6
22.6
1.7
29.2
1410
500
16x2x1
0.6
1.6
25.2
1.7
31.8
1629
500
20x2x1
0.6
28.2
1.8
35.8
2161
500
24x2x1
0.6
31.5
1.9
39.3
2440
500
30x2x1
0.6
33.5
1.9
41.3
2728
500
Instrument Cables
190
1x2x1.5
0.6
0.9
8.8
1.4
13.4
324
1000
2x2x1.5
0.6
0.9
13.0
1.4
17.6
482
1000
3x2x1.5
0.6
0.9
13.9
1.5
18.7
551
1000
4x2x1.5
0.6
0.9
15.3
1.5
20.1
634
1000
5x2x1.5
0.6
1.25
16.8
1.5
22.3
855
1000
6x2x1.5
0.6
1.25
18.4
1.6
24.1
954
1000
7x2x1.5
0.6
1.25
18.4
1.6
24.1
996
1000
10x2x1.5
0.6
1.6
23.7
1.7
30.3
1513
500
12x2x1.5
0.6
1.6
24.6
1.7
31.2
1624
500
16x2x1.5
0.6
1.6
27.5
1.8
34.3
1940
500
20x2x1.5
0.6
30.9
1.9
38.7
2519
500
24x2x1.5
0.6
34.5
2.0
42.5
2904
500
30x2x1.5
0.6
2.5
37.1
2.1
46.3
3755
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.9
10.1
1.4
14.7
380
1000
2x2x2.5
0.7
0.9
15.0
1.5
19.8
587
1000
3x2x2.5
0.7
1.25
16.1
1.5
21.6
810
1000
4x2x2.5
0.7
1.25
17.7
1.6
23.4
942
1000
5x2x2.5
0.7
1.25
19.5
1.6
25.2
1066
500
6x2x2.5
0.7
1.25
21.4
1.7
27.3
1213
500
7x2x2.5
0.7
1.25
21.4
1.7
27.3
1278
500
10x2x2.5
0.7
27.8
1.8
35.4
2164
500
12x2x2.5
0.7
28.8
1.9
36.6
2345
500
16x2x2.5
0.7
32.3
1.9
40.1
2800
500
20x2x2.5
0.7
2.5
36.7
2.1
45.9
3729
500
24x2x2.5
0.7
2.5
41.0
2.2
50.4
4268
250
30x2x2.5
0.7
3.15
43.6
2.3
54.5
5491
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
191
KCI
RE-2X(St)YRY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
IEC 60331
Instrument Cables
Criteria
192
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.9
1.3
12.3
278
1000
2x3x0.5
0.6
0.9
11.9
1.4
16.5
420
1000
3x3x0.5
0.6
0.9
12.7
1.4
17.3
472
1000
4x3x0.5
0.6
0.9
14.0
1.5
18.8
542
1000
5x3x0.5
0.6
0.9
15.3
1.5
20.1
605
1000
6x3x0.5
0.6
1.25
16.7
1.5
22.2
801
1000
7x3x0.5
0.6
1.25
16.7
1.5
22.2
829
1000
10x3x0.5
0.6
1.25
21.6
1.6
27.3
1097
500
12x3x0.5
0.6
1.6
22.3
1.7
28.9
1362
500
16x3x0.5
0.6
1.6
24.9
1.7
31.5
1588
500
20x3x0.5
0.6
28.0
1.8
35.6
2084
500
24x3x0.5
0.6
31.2
1.9
39.0
2379
500
30x3x0.5
0.6
33.2
1.9
41.0
2652
500
1x3x0.75
0.6
0.9
8.3
1.3
12.7
297
1000
2x3x0.75
0.6
0.9
12.7
1.4
17.3
463
1000
3x3x0.75
0.6
0.9
13.5
1.5
18.3
526
1000
4x3x0.75
0.6
0.9
14.9
1.5
19.7
604
1000
5x3x0.75
0.6
1.25
16.4
1.5
21.9
815
1000
6x3x0.75
0.6
1.25
17.9
1.6
23.6
908
1000
7x3x0.75
0.6
1.25
17.9
1.6
23.6
946
1000
10x3x0.75
0.6
1.6
23.1
1.7
29.7
1439
500
12x3x0.75
0.6
1.6
24.0
1.7
30.6
1540
500
16x3x0.75
0.6
1.6
26.8
1.8
33.6
1818
500
20x3x0.75
0.6
30.1
1.9
37.9
2383
500
24x3x0.75
0.6
33.6
1.9
41.4
2705
500
30x3x0.75
0.6
2.5
36.1
2.0
45.1
3534
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
193
KCI
RE-2X(St)YRY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
8.7
1.4
13.3
320
1000
2x3x1
0.6
0.9
13.4
1.4
18.0
497
1000
3x3x1
0.6
0.9
14.3
1.5
19.1
575
1000
4x3x1
0.6
1.25
15.7
1.5
21.2
785
1000
5x3x1
0.6
1.25
17.3
1.5
22.8
888
1000
6x3x1
0.6
1.25
18.9
1.6
24.6
1001
500
7x3x1
0.6
1.25
18.9
1.6
24.6
1048
500
10x3x1
0.6
1.6
24.5
1.7
31.1
1574
500
12x3x1
0.6
1.6
25.4
1.7
32.0
1710
500
16x3x1
0.6
28.4
1.8
36.0
2287
500
20x3x1
0.6
31.9
1.9
39.7
2657
500
24x3x1
0.6
2.5
35.6
2.0
44.6
3439
500
30x3x1
0.6
2.5
38.3
2.1
47.5
3924
500
Instrument Cables
194
1x3x1.5
0.6
0.9
9.4
1.4
14.0
361
1000
2x3x1.5
0.6
0.9
14.5
1.5
19.3
573
1000
3x3x1.5
0.6
0.9
15.5
1.5
20.3
663
1000
4x3x1.5
0.6
1.25
17.1
1.6
22.8
909
1000
5x3x1.5
0.6
1.25
18.8
1.6
24.5
1032
1000
6x3x1.5
0.6
1.25
20.6
1.6
26.3
1166
500
7x3x1.5
0.6
1.25
20.6
1.6
26.3
1230
500
10x3x1.5
0.6
1.6
26.7
1.8
33.5
1855
500
12x3x1.5
0.6
27.7
1.8
35.3
2279
500
16x3x1.5
0.6
31.0
1.9
38.8
2717
500
20x3x1.5
0.6
2.5
35.3
2.0
44.3
3633
500
24x3x1.5
0.6
2.5
39.3
2.1
48.5
4123
500
30x3x1.5
0.6
2.5
41.9
2.2
51.3
4681
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.9
10.7
1.4
15.3
429
1000
2x3x2.5
0.7
1.25
16.8
1.6
22.5
847
1000
3x3x2.5
0.7
1.25
18.0
1.6
23.7
977
1000
4x3x2.5
0.7
1.25
19.9
1.6
25.6
1145
500
5x3x2.5
0.7
1.6
21.9
1.7
28.5
1488
500
6x3x2.5
0.7
1.6
24.1
1.7
30.7
1676
500
7x3x2.5
0.7
1.6
24.1
1.7
30.7
1772
500
10x3x2.5
0.7
31.4
1.9
39.2
2672
500
12x3x2.5
0.7
32.5
1.9
40.3
2932
500
16x3x2.5
0.7
2.5
36.8
2.1
46.0
3989
500
20x3x2.5
0.7
2.5
41.4
2.2
50.8
4702
250
24x3x2.5
0.7
3.15
46.3
2.3
57.2
6046
250
30x3x2.5
0.7
3.15
49.7
2.4
60.8
6935
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
195
KCI
RE-2X(St)YRY , PiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
196
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
7.8
1.3
12.2
277
1000
2x2x0.5
0.6
0.9
12.1
1.4
16.7
426
1000
3x2x0.5
0.6
0.9
12.9
1.4
17.5
472
1000
4x2x0.5
0.6
0.9
14.2
1.5
19.0
541
1000
5x2x0.5
0.6
0.9
15.5
1.5
20.3
610
1000
6x2x0.5
0.6
1.25
17.0
1.5
22.5
810
1000
7x2x0.5
0.6
1.25
17.0
1.5
22.5
838
1000
10x2x0.5
0.6
1.6
21.9
1.7
28.5
1276
500
12x2x0.5
0.6
1.6
22.7
1.7
29.3
1374
500
16x2x0.5
0.6
1.6
25.4
1.7
32.0
1598
500
20x2x0.5
0.6
28.4
1.8
36.0
2101
500
24x2x0.5
0.6
31.7
1.9
39.5
2395
500
30x2x0.5
0.6
33.7
1.9
41.5
2664
500
1x2x0.75
0.6
0.9
8.2
1.3
12.6
293
1000
2x2x0.75
0.6
0.9
12.8
1.4
17.4
458
1000
3x2x0.75
0.6
0.9
13.7
1.5
18.5
523
1000
4x2x0.75
0.6
0.9
15.1
1.5
19.9
593
1000
5x2x0.75
0.6
1.25
16.5
1.5
22.0
800
1000
6x2x0.75
0.6
1.25
18.1
1.6
23.8
900
1000
7x2x0.75
0.6
1.25
18.1
1.6
23.8
935
1000
10x2x0.75
0.6
1.6
23.4
1.7
30.0
1408
500
12x2x0.75
0.6
1.6
24.3
1.7
30.9
1520
500
16x2x0.75
0.6
1.6
27.1
1.8
33.9
1784
500
20x2x0.75
0.6
30.4
1.9
38.2
2346
500
24x2x0.75
0.6
34.0
1.9
41.8
2655
500
30x2x0.75
0.6
2.5
36.5
2.0
45.5
3439
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
197
KCI
RE-2X(St)YRY , PiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
8.6
1.4
13.2
313
1000
2x2x1
0.6
0.9
13.5
1.5
18.3
493
1000
3x2x1
0.6
0.9
14.4
1.5
19.2
559
1000
4x2x1
0.6
1.25
15.8
1.5
21.3
762
1000
5x2x1
0.6
1.25
17.4
1.6
23.1
868
1000
6x2x1
0.6
1.25
19.1
1.6
24.8
967
500
7x2x1
0.6
1.25
19.1
1.6
24.8
1007
500
10x2x1
0.6
1.6
24.7
1.7
31.3
1516
500
12x2x1
0.6
1.6
25.6
1.7
32.2
1640
500
16x2x1
0.6
28.6
1.8
36.2
2193
500
20x2x1
0.6
32.1
1.9
39.9
2540
500
24x2x1
0.6
2.5
36.3
2.0
45.3
3376
500
30x2x1
0.6
2.5
38.6
2.1
47.8
3748
500
Instrument Cables
198
1x2x1.5
0.6
0.9
9.2
1.4
13.8
342
1000
2x2x1.5
0.6
0.9
14.6
1.5
19.4
551
1000
3x2x1.5
0.6
0.9
15.5
1.5
20.3
630
1000
4x2x1.5
0.6
1.25
17.1
1.6
22.8
865
1000
5x2x1.5
0.6
1.25
18.9
1.6
24.6
976
500
6x2x1.5
0.6
1.25
20.7
1.6
26.4
1099
500
7x2x1.5
0.6
1.25
20.7
1.6
26.4
1152
500
10x2x1.5
0.6
1.6
26.8
1.8
33.6
1743
500
12x2x1.5
0.6
27.8
1.8
35.4
2144
500
16x2x1.5
0.6
31.1
1.9
38.9
2537
500
20x2x1.5
0.6
2.5
35.4
2.0
44.4
3408
500
24x2x1.5
0.6
2.5
39.5
2.1
48.7
3893
500
30x2x1.5
0.6
2.5
42.0
2.2
51.4
4384
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.9
10.4
1.4
15.0
400
1000
2x2x2.5
0.7
1.25
16.8
1.6
22.5
804
1000
3x2x2.5
0.7
1.25
17.9
1.6
23.6
912
1000
4x2x2.5
0.7
1.25
19.8
1.6
25.5
1059
500
5x2x2.5
0.7
1.6
21.8
1.7
28.4
1381
500
6x2x2.5
0.7
1.6
24.0
1.7
30.6
1547
500
7x2x2.5
0.7
1.6
24.0
1.7
30.6
1622
500
10x2x2.5
0.7
31.2
1.9
39.0
2458
500
12x2x2.5
0.7
32.4
1.9
40.2
2675
500
16x2x2.5
0.7
2.5
36.7
2.1
45.9
3647
500
20x2x2.5
0.7
2.5
41.3
2.2
50.7
4274
250
24x2x2.5
0.7
3.15
46.1
2.3
57.0
5532
250
30x2x2.5
0.7
3.15
49.5
2.4
60.6
6294
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
199
KCI
RE-2X(St)YRY , TiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Blue,White,Red (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
200
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
8.2
1.3
12.6
296
1000
2x3x0.5
0.6
0.9
13.4
1.4
18.0
480
1000
3x3x0.5
0.6
0.9
14.3
1.5
19.1
550
1000
4x3x0.5
0.6
1.25
15.8
1.5
21.3
750
1000
5x3x0.5
0.6
1.25
17.3
1.5
22.8
845
1000
6x3x0.5
0.6
1.25
19.0
1.6
24.7
949
500
7x3x0.5
0.6
1.25
19.0
1.6
24.7
987
500
10x3x0.5
0.6
1.6
24.6
1.7
31.2
1488
500
12x3x0.5
0.6
1.6
25.5
1.7
32.1
1606
500
16x3x0.5
0.6
28.5
1.8
36.1
2148
500
20x3x0.5
0.6
32.0
1.9
39.8
2484
500
24x3x0.5
0.6
2.5
36.1
2.0
45.1
3309
500
30x3x0.5
0.6
2.5
38.4
2.1
47.6
3664
500
1x3x0.75
0.6
0.9
8.7
1.4
13.3
321
1000
2x3x0.75
0.6
0.9
14.3
1.5
19.1
531
1000
3x3x0.75
0.6
0.9
15.2
1.5
20.0
604
1000
4x3x0.75
0.6
1.25
16.8
1.5
22.3
830
1000
5x3x0.75
0.6
1.25
18.5
1.6
24.2
945
1000
6x3x0.75
0.6
1.25
20.3
1.6
26.0
1052
500
7x3x0.75
0.6
1.25
20.3
1.6
26.0
1099
500
10x3x0.75
0.6
1.6
26.3
1.8
33.1
1665
500
12x3x0.75
0.6
1.6
27.2
1.8
34.0
1804
500
16x3x0.75
0.6
30.5
1.9
38.3
2416
500
20x3x0.75
0.6
34.3
2.0
42.3
2795
500
24x3x0.75
0.6
2.5
38.7
2.1
47.9
3711
500
30x3x0.75
0.6
2.5
41.1
2.1
50.3
4108
250
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
201
KCI
RE-2X(St)YRY , TiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
9.1
1.4
13.7
344
1000
2x3x1
0.6
0.9
15.0
1.5
19.8
567
1000
3x3x1
0.6
1.25
16.0
1.5
21.5
781
1000
4x3x1
0.6
1.25
17.7
1.6
23.4
904
1000
5x3x1
0.6
1.25
19.5
1.6
25.2
1020
500
6x3x1
0.6
1.25
21.4
1.6
27.1
1137
500
7x3x1
0.6
1.25
21.4
1.6
27.1
1194
500
10x3x1
0.6
27.7
1.8
35.3
2073
500
12x3x1
0.6
28.8
1.8
36.4
2223
500
16x3x1
0.6
32.2
1.9
40.0
2633
500
20x3x1
0.6
2.5
36.6
2.0
45.6
3536
500
24x3x1
0.6
2.5
40.9
2.1
50.1
4038
250
30x3x1
0.6
2.5
43.5
2.2
52.9
4553
250
Instrument Cables
202
1x3x1.5
0.6
0.9
9.7
1.4
14.3
380
1000
2x3x1.5
0.6
1.25
16.2
1.5
21.7
764
1000
3x3x1.5
0.6
1.25
17.3
1.6
23.0
890
1000
4x3x1.5
0.6
1.25
19.2
1.6
24.9
1024
500
5x3x1.5
0.6
1.25
21.1
1.6
26.8
1170
500
6x3x1.5
0.6
1.6
23.2
1.7
29.8
1510
500
7x3x1.5
0.6
1.6
23.2
1.7
29.8
1585
500
10x3x1.5
0.6
30.2
1.9
38.0
2376
500
12x3x1.5
0.6
31.3
1.9
39.1
2590
500
16x3x1.5
0.6
2.5
35.4
2.0
44.4
3546
500
20x3x1.5
0.6
2.5
39.8
2.1
49.0
4122
500
24x3x1.5
0.6
2.5
44.5
2.2
53.9
4705
250
30x3x1.5
0.6
3.15
47.4
2.3
58.3
6022
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.9
11.1
1.4
15.7
450
1000
2x3x2.5
0.7
1.25
18.7
1.6
24.4
932
1000
3x3x2.5
0.7
1.25
20.1
1.6
25.8
1085
500
4x3x2.5
0.7
1.6
22.2
1.7
28.8
1457
500
5x3x2.5
0.7
1.6
24.5
1.8
31.3
1670
500
6x3x2.5
0.7
1.6
27.0
1.8
33.8
1890
500
7x3x2.5
0.7
1.6
27.0
1.8
33.8
1998
500
10x3x2.5
0.7
2.5
35.6
2.0
44.6
3449
500
12x3x2.5
0.7
2.5
36.9
2.1
46.1
3782
500
16x3x2.5
0.7
2.5
41.4
2.2
50.8
4498
250
20x3x2.5
0.7
3.15
46.9
2.3
57.8
6003
250
24x3x2.5
0.7
3.15
52.5
2.5
63.8
6891
250
30x3x2.5
0.7
3.15
55.8
2.5
67.1
7788
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
203
KCI
RE-Y(St)YBY
EN 50288-7 (500 V)
RE-Y(St)YBY Multi-Core
RE-Y(St)YBY Multi-Pair
RE-Y(St)YBY Multi-Triple
RE-Y(St)YBY PiMF
RE-Y(St)YBY TiMF
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
RE-2X(St)BH
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-Y(St)YBY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
206
PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.2
6.5
1.3
9.9
149
1000
3x0.5
0.6
0.2
6.8
1.3
10.2
164
1000
4x0.5
0.6
0.2
7.4
1.3
10.8
182
1000
5x0.5
0.6
0.2
8.0
1.3
11.4
201
1000
6x0.5
0.6
0.2
8.6
1.3
12.0
220
1000
7x0.5
0.6
0.2
8.6
1.3
12.0
229
1000
8x0.5
0.6
0.2
9.8
1.4
13.4
265
1000
10x0.5
0.6
0.2
10.7
1.4
14.3
298
1000
12x0.5
0.6
0.2
11.0
1.4
14.6
321
1000
16x0.5
0.6
0.2
12.2
1.4
15.8
376
1000
20x0.5
0.6
0.2
13.5
1.4
17.1
435
1000
24x0.5
0.6
0.2
14.9
1.5
18.7
502
1000
30x0.5
0.6
0.2
15.7
1.5
19.5
570
1000
2x0.75
0.6
0.2
6.9
1.3
10.3
163
1000
3x0.75
0.6
0.2
7.3
1.3
10.7
181
1000
4x0.75
0.6
0.2
7.9
1.3
11.3
203
1000
5x0.75
0.6
0.2
8.5
1.3
11.9
226
1000
6x0.75
0.6
0.2
9.2
1.4
12.8
255
1000
7x0.75
0.6
0.2
9.2
1.4
12.8
267
1000
8x0.75
0.6
0.2
10.6
1.4
14.2
304
1000
10x0.75
0.6
0.2
11.5
1.4
15.1
344
1000
12x0.75
0.6
0.2
11.9
1.4
15.5
374
1000
16x0.75
0.6
0.2
13.1
1.4
16.7
443
1000
20x0.75
0.6
0.2
14.6
1.5
18.4
523
1000
24x0.75
0.6
0.2
16.1
1.5
19.9
599
1000
30x0.75
0.6
0.2
17.1
1.5
20.9
686
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
207
KCI
RE-Y(St)YBY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.2
7.3
1.3
10.7
174
1000
3x1
0.6
0.2
7.7
1.3
11.1
196
1000
4x1
0.6
0.2
8.3
1.3
11.7
222
1000
5x1
0.6
0.2
9.0
1.3
12.4
249
1000
6x1
0.6
0.2
9.8
1.4
13.4
282
1000
7x1
0.6
0.2
9.8
1.4
13.4
297
1000
8x1
0.6
0.2
11.3
1.4
14.9
338
1000
10x1
0.6
0.2
12.2
1.4
15.8
385
1000
12x1
0.6
0.2
12.6
1.4
16.2
422
1000
16x1
0.6
0.2
14.0
1.5
17.8
512
1000
20x1
0.6
0.2
15.6
1.5
19.4
599
1000
24x1
0.6
0.2
17.2
1.5
21.0
688
1000
30x1
0.6
0.2
18.2
1.5
22.0
795
1000
Instrument Cables
208
2x1.5
0.6
0.2
7.9
1.3
11.3
197
1000
3x1.5
0.6
0.2
8.3
1.3
11.7
226
1000
4x1.5
0.6
0.2
9.0
1.3
12.4
259
1000
5x1.5
0.6
0.2
9.8
1.4
13.4
299
1000
6x1.5
0.6
0.2
10.7
1.4
14.3
334
1000
7x1.5
0.6
0.2
10.7
1.4
14.3
355
1000
8x1.5
0.6
0.2
12.3
1.4
15.9
405
1000
10x1.5
0.6
0.2
13.4
1.4
17.0
466
1000
12x1.5
0.6
0.2
13.9
1.5
17.7
522
1000
16x1.5
0.6
0.2
15.4
1.5
19.2
632
1000
20x1.5
0.6
0.2
17.2
1.5
21.0
746
1000
24x1.5
0.6
0.2
19.0
1.6
23.0
872
1000
30x1.5
0.6
0.2
20.2
1.6
24.2
1016
1000
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.2
9.1
1.4
12.7
248
1000
3x2.5
0.7
0.2
9.7
1.4
13.3
290
1000
4x2.5
0.7
0.2
10.5
1.4
14.1
338
1000
5x2.5
0.7
0.2
11.5
1.4
15.1
387
1000
6x2.5
0.7
0.2
12.5
1.4
16.1
437
1000
7x2.5
0.7
0.2
12.5
1.4
16.1
469
1000
8x2.5
0.7
0.2
14.6
1.5
18.4
545
1000
10x2.5
0.7
0.2
15.9
1.5
19.7
634
1000
12x2.5
0.7
0.2
16.5
1.5
20.3
708
1000
16x2.5
0.7
0.2
18.3
1.6
22.3
879
1000
20x2.5
0.7
0.2
20.5
1.6
24.5
1047
1000
24x2.5
0.7
0.2
22.7
1.7
26.9
1228
500
30x2.5
0.7
0.2
24.1
1.7
28.3
1446
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
209
KCI
RE-Y(St)YBY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
210
Extruded PVC
Galvanized Steel Tapes
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.2
6.5
1.3
9.9
149
1000
2x2x0.5
0.6
0.2
9.2
1.3
12.6
214
1000
3x2x0.5
0.6
0.2
9.7
1.4
13.3
247
1000
4x2x0.5
0.6
0.2
10.6
1.4
14.2
281
1000
5x2x0.5
0.6
0.2
11.6
1.4
15.2
316
1000
6x2x0.5
0.6
0.2
12.6
1.4
16.2
352
1000
7x2x0.5
0.6
0.2
12.6
1.4
16.2
370
1000
10x2x0.5
0.6
0.2
16.1
1.5
19.9
492
1000
12x2x0.5
0.6
0.2
16.6
1.5
20.4
538
1000
16x2x0.5
0.6
0.2
18.5
1.6
22.5
652
1000
20x2x0.5
0.6
0.2
20.6
1.6
24.6
763
500
24x2x0.5
0.6
0.2
23.0
1.7
27.2
888
500
30x2x0.5
0.6
0.2
24.4
1.7
28.6
1021
500
1x2x0.75
0.6
0.2
6.9
1.3
10.3
163
1000
2x2x0.75
0.6
0.2
9.9
1.4
13.5
244
1000
3x2x0.75
0.6
0.2
10.5
1.4
14.1
279
1000
4x2x0.75
0.6
0.2
11.5
1.4
15.1
321
1000
5x2x0.75
0.6
0.2
12.5
1.4
16.1
364
1000
6x2x0.75
0.6
0.2
13.7
1.5
17.5
415
1000
7x2x0.75
0.6
0.2
13.7
1.5
17.5
439
1000
10x2x0.75
0.6
0.2
17.4
1.5
21.2
580
1000
12x2x0.75
0.6
0.2
18.0
1.6
22.0
648
1000
16x2x0.75
0.6
0.2
20.1
1.6
24.1
782
1000
20x2x0.75
0.6
0.2
22.5
1.7
26.7
932
500
24x2x0.75
0.6
0.2
25.0
1.7
29.2
1076
500
30x2x0.75
0.6
0.2
26.6
1.7
30.8
1250
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
211
KCI
RE-Y(St)YBY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.2
7.3
1.3
10.7
175
1000
2x2x1
0.6
0.2
10.5
1.4
14.1
266
1000
3x2x1
0.6
0.2
11.1
1.4
14.7
308
1000
4x2x1
0.6
0.2
12.2
1.4
15.8
357
1000
5x2x1
0.6
0.2
13.3
1.4
16.9
407
1000
6x2x1
0.6
0.2
14.5
1.5
18.3
466
1000
7x2x1
0.6
0.2
14.5
1.5
18.3
496
1000
10x2x1
0.6
0.2
18.6
1.6
22.6
669
1000
12x2x1
0.6
0.2
19.3
1.6
23.3
741
1000
16x2x1
0.6
0.2
21.5
1.6
25.5
902
500
20x2x1
0.6
0.2
24.1
1.7
28.3
1081
500
24x2x1
0.6
0.2
26.8
1.7
31.0
1253
500
30x2x1
0.6
0.2
28.5
1.8
32.9
1477
500
Instrument Cables
212
1x2x1.5
0.6
0.2
7.9
1.3
11.3
198
1000
2x2x1.5
0.6
0.2
11.4
1.4
15.0
309
1000
3x2x1.5
0.6
0.2
12.2
1.4
15.8
364
1000
4x2x1.5
0.6
0.2
13.4
1.4
17.0
427
1000
5x2x1.5
0.6
0.2
14.6
1.5
18.4
499
1000
6x2x1.5
0.6
0.2
16.0
1.5
19.8
566
1000
7x2x1.5
0.6
0.2
16.0
1.5
19.8
608
1000
10x2x1.5
0.6
0.2
20.6
1.6
24.6
827
500
12x2x1.5
0.6
0.2
21.3
1.6
25.3
925
500
16x2x1.5
0.6
0.2
23.8
1.7
28.0
1149
500
20x2x1.5
0.6
0.2
26.7
1.8
31.1
1384
500
24x2x1.5
0.6
0.2
29.7
1.8
34.1
1611
500
30x2x1.5
0.6
0.2
31.6
1.9
36.2
1913
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.2
9.1
1.4
12.7
249
1000
2x2x2.5
0.7
0.2
13.5
1.5
17.3
400
1000
3x2x2.5
0.7
0.2
14.4
1.5
18.2
482
1000
4x2x2.5
0.7
0.2
15.8
1.5
19.6
574
1000
5x2x2.5
0.7
0.2
17.4
1.5
21.2
668
1000
6x2x2.5
0.7
0.2
19.1
1.6
23.1
773
1000
7x2x2.5
0.7
0.2
19.1
1.6
23.1
838
1000
10x2x2.5
0.7
0.2
24.7
1.7
28.9
1150
500
12x2x2.5
0.7
0.2
25.6
1.7
29.8
1297
500
16x2x2.5
0.7
0.2
28.6
1.8
33.0
1629
500
20x2x2.5
0.7
0.2
32.5
1.9
37.1
2009
500
24x2x2.5
0.7
0.5
36.2
2.0
42.2
2801
500
30x2x2.5
0.7
0.5
38.5
2.1
44.7
3284
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
213
KCI
RE-Y(St)YBY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Tapes
Outer Sheath
Extruded PVC
+70 oC
IEC 60332-1
Instrument Cables
Criteria
214
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.2
6.8
1.3
10.2
164
1000
2x3x0.5
0.6
0.2
10.1
1.4
13.7
254
1000
3x3x0.5
0.6
0.2
10.8
1.4
14.4
292
1000
4x3x0.5
0.6
0.2
11.8
1.4
15.4
337
1000
5x3x0.5
0.6
0.2
12.9
1.4
16.5
383
1000
6x3x0.5
0.6
0.2
14.1
1.5
17.9
438
1000
7x3x0.5
0.6
0.2
14.1
1.5
17.9
465
1000
10x3x0.5
0.6
0.2
18.0
1.5
21.8
616
1000
12x3x0.5
0.6
0.2
18.6
1.6
22.6
690
1000
16x3x0.5
0.6
0.2
20.7
1.6
24.7
836
500
20x3x0.5
0.6
0.2
23.2
1.7
27.4
999
500
24x3x0.5
0.6
0.2
25.8
1.7
30.0
1156
500
30x3x0.5
0.6
0.2
27.4
1.8
31.8
1359
500
1x3x0.75
0.6
0.2
7.3
1.3
10.7
182
1000
2x3x0.75
0.6
0.2
10.9
1.4
14.5
287
1000
3x3x0.75
0.6
0.2
11.6
1.4
15.2
336
1000
4x3x0.75
0.6
0.2
12.7
1.4
16.3
392
1000
5x3x0.75
0.6
0.2
13.9
1.5
17.7
456
1000
6x3x0.75
0.6
0.2
15.2
1.5
19.0
516
1000
7x3x0.75
0.6
0.2
15.2
1.5
19.0
552
1000
10x3x0.75
0.6
0.2
19.6
1.6
23.6
748
1000
12x3x0.75
0.6
0.2
20.2
1.6
24.2
832
1000
16x3x0.75
0.6
0.2
22.6
1.7
26.8
1030
500
20x3x0.75
0.6
0.2
25.3
1.7
29.5
1225
500
24x3x0.75
0.6
0.2
28.2
1.8
32.6
1437
500
30x3x0.75
0.6
0.2
30.0
1.8
34.4
1686
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
215
KCI
RE-Y(St)YRY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.2
7.7
1.3
11.1
197
1000
2x3x1
0.6
0.2
11.6
1.4
15.2
316
1000
3x3x1
0.6
0.2
12.3
1.4
15.9
375
1000
4x3x1
0.6
0.2
13.5
1.4
17.1
441
1000
5x3x1
0.6
0.2
14.8
1.5
18.6
517
1000
6x3x1
0.6
0.2
16.2
1.5
20.0
587
1000
7x3x1
0.6
0.2
16.2
1.5
20.0
632
1000
10x3x1
0.6
0.2
20.9
1.6
24.9
861
500
12x3x1
0.6
0.2
21.6
1.6
25.6
965
500
16x3x1
0.6
0.2
24.2
1.7
28.4
1203
500
20x3x1
0.6
0.2
27.1
1.7
31.3
1438
500
24x3x1
0.6
0.2
30.2
1.8
34.6
1691
500
30x3x1
0.6
0.2
32.1
1.9
36.7
2012
500
Instrument Cables
216
1x3x1.5
0.6
0.2
8.3
1.3
11.7
227
1000
2x3x1.5
0.6
0.2
12.7
1.4
16.3
373
1000
3x3x1.5
0.6
0.2
13.5
1.5
17.3
458
1000
4x3x1.5
0.6
0.2
14.9
1.5
18.7
546
1000
5x3x1.5
0.6
0.2
16.4
1.5
20.2
635
1000
6x3x1.5
0.6
0.2
17.9
1.6
21.9
736
1000
7x3x1.5
0.6
0.2
17.9
1.6
21.9
798
1000
10x3x1.5
0.6
0.2
23.1
1.7
27.3
1095
500
12x3x1.5
0.6
0.2
24.0
1.7
28.2
1236
500
16x3x1.5
0.6
0.2
26.8
1.8
31.2
1554
500
20x3x1.5
0.6
0.2
30.1
1.8
34.5
1869
500
24x3x1.5
0.6
0.2
34.0
1.9
38.6
2240
500
30x3x1.5
0.6
0.5
36.1
2.0
42.1
3112
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.2
9.7
1.4
13.3
292
1000
2x3x2.5
0.7
0.2
15.0
1.5
18.8
494
1000
3x3x2.5
0.7
0.2
16.0
1.5
19.8
610
1000
4x3x2.5
0.7
0.2
17.7
1.6
21.7
747
1000
5x3x2.5
0.7
0.2
19.5
1.6
23.5
879
1000
6x3x2.5
0.7
0.2
21.4
1.6
25.4
1012
500
7x3x2.5
0.7
0.2
21.4
1.6
25.4
1110
500
10x3x2.5
0.7
0.2
27.8
1.8
32.2
1548
500
12x3x2.5
0.7
0.2
28.8
1.8
33.2
1763
500
16x3x2.5
0.7
0.2
32.6
1.9
37.2
2272
500
20x3x2.5
0.7
0.5
36.6
2.0
42.6
3204
500
24x3x2.5
0.7
0.5
40.9
2.1
47.1
3753
500
30x3x2.5
0.7
0.5
43.5
2.2
49.9
4444
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
217
KCI
RE-Y(St)YBY , PiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
218
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.2
6.8
1.3
10.2
164
1000
2x2x0.5
0.6
0.2
10.4
1.4
14.0
257
1000
3x2x0.5
0.6
0.2
11.0
1.4
14.6
295
1000
4x2x0.5
0.6
0.2
12.1
1.4
15.7
339
1000
5x2x0.5
0.6
0.2
13.2
1.4
16.8
385
1000
6x2x0.5
0.6
0.2
14.4
1.5
18.2
440
1000
7x2x0.5
0.6
0.2
14.4
1.5
18.2
466
1000
10x2x0.5
0.6
0.2
18.5
1.6
22.5
626
1000
12x2x0.5
0.6
0.2
19.2
1.6
23.2
690
1000
16x2x0.5
0.6
0.2
21.3
1.6
25.3
834
500
20x2x0.5
0.6
0.2
23.9
1.7
28.1
996
500
24x2x0.5
0.6
0.2
26.6
1.7
30.8
1151
500
30x2x0.5
0.6
0.2
28.3
1.8
32.7
1350
500
1x2x0.75
0.6
0.2
7.3
1.3
10.7
178
1000
2x2x0.75
0.6
0.2
11.1
1.4
14.7
284
1000
3x2x0.75
0.6
0.2
11.9
1.4
15.5
329
1000
4x2x0.75
0.6
0.2
13.0
1.4
16.6
382
1000
5x2x0.75
0.6
0.2
14.2
1.5
18.0
444
1000
6x2x0.75
0.6
0.2
15.6
1.5
19.4
501
1000
7x2x0.75
0.6
0.2
15.6
1.5
19.4
533
1000
10x2x0.75
0.6
0.2
20.0
1.6
24.0
721
1000
12x2x0.75
0.6
0.2
20.7
1.6
24.7
798
500
16x2x0.75
0.6
0.2
23.1
1.7
27.3
983
500
20x2x0.75
0.6
0.2
25.9
1.7
30.1
1166
500
24x2x0.75
0.6
0.2
28.9
1.8
33.3
1365
500
30x2x0.75
0.6
0.2
30.7
1.8
35.1
1594
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
219
KCI
RE-Y(St)YBY , PiMF
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.2
7.6
1.3
11.0
190
1000
2x2x1
0.6
0.2
11.8
1.4
15.4
307
1000
3x2x1
0.6
0.2
12.5
1.4
16.1
360
1000
4x2x1
0.6
0.2
13.8
1.4
17.4
420
1000
5x2x1
0.6
0.2
15.1
1.5
18.9
490
1000
6x2x1
0.6
0.2
16.5
1.5
20.3
555
1000
7x2x1
0.6
0.2
16.5
1.5
20.3
593
1000
10x2x1
0.6
0.2
21.3
1.6
25.3
806
500
12x2x1
0.6
0.2
22.0
1.6
26.0
897
500
16x2x1
0.6
0.2
24.6
1.7
28.8
1111
500
20x2x1
0.6
0.2
27.6
1.8
32.0
1335
500
24x2x1
0.6
0.2
30.8
1.8
35.2
1551
500
30x2x1
0.6
0.2
32.7
1.9
37.3
1835
500
Instrument Cables
220
1x2x1.5
0.6
0.2
8.2
1.3
11.6
214
1000
2x2x1.5
0.6
0.2
12.8
1.4
16.4
352
1000
3x2x1.5
0.6
0.2
13.7
1.5
17.5
426
1000
4x2x1.5
0.6
0.2
15.1
1.5
18.9
502
1000
5x2x1.5
0.6
0.2
16.5
1.5
20.3
580
1000
6x2x1.5
0.6
0.2
18.1
1.6
22.1
669
1000
7x2x1.5
0.6
0.2
18.1
1.6
22.1
720
1000
10x2x1.5
0.6
0.2
23.4
1.7
27.6
983
500
12x2x1.5
0.6
0.2
24.3
1.7
28.5
1101
500
16x2x1.5
0.6
0.2
27.1
1.8
31.5
1372
500
20x2x1.5
0.6
0.2
30.4
1.8
34.8
1641
500
24x2x1.5
0.6
0.2
34.4
1.9
39.0
1966
500
30x2x1.5
0.6
0.5
36.5
2.0
42.5
2774
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.2
9.5
1.4
13.1
266
1000
2x2x2.5
0.7
0.2
15.1
1.5
18.9
450
1000
3x2x2.5
0.7
0.2
16.1
1.5
19.9
544
1000
4x2x2.5
0.7
0.2
17.7
1.6
21.7
658
1000
5x2x2.5
0.7
0.2
19.5
1.6
23.5
767
1000
6x2x2.5
0.7
0.2
21.4
1.6
25.4
879
500
7x2x2.5
0.7
0.2
21.4
1.6
25.4
954
500
10x2x2.5
0.7
0.2
27.8
1.8
32.2
1325
500
12x2x2.5
0.7
0.2
28.8
1.8
33.2
1496
500
16x2x2.5
0.7
0.2
32.7
1.9
37.3
1915
500
20x2x2.5
0.7
0.5
36.7
2.0
42.7
2759
500
24x2x2.5
0.7
0.5
41.0
2.1
47.2
3218
500
30x2x2.5
0.7
0.5
43.6
2.2
50.0
3776
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
221
KCI
RE-Y(St)YBY , TiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
Instrument Cables
+70 oC
PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Galvanized Steel Tapes
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
222
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.2
7.2
1.3
10.6
179
1000
2x3x0.5
0.6
0.2
11.5
1.4
15.1
295
1000
3x3x0.5
0.6
0.2
12.2
1.4
15.8
343
1000
4x3x0.5
0.6
0.2
13.4
1.4
17.0
399
1000
5x3x0.5
0.6
0.2
14.7
1.5
18.5
465
1000
6x3x0.5
0.6
0.2
16.1
1.5
19.9
525
1000
7x3x0.5
0.6
0.2
16.1
1.5
19.9
560
1000
10x3x0.5
0.6
0.2
20.7
1.6
24.7
758
500
12x3x0.5
0.6
0.2
21.4
1.6
25.4
842
500
16x3x0.5
0.6
0.2
23.9
1.7
28.1
1039
500
20x3x0.5
0.6
0.2
26.8
1.7
31.0
1234
500
24x3x0.5
0.6
0.2
29.9
1.8
34.3
1446
500
30x3x0.5
0.6
0.2
31.8
1.9
36.4
1707
500
1x3x0.75
0.6
0.2
7.6
1.3
11.0
197
1000
2x3x0.75
0.6
0.2
12.3
1.4
15.9
330
1000
3x3x0.75
0.6
0.2
13.1
1.4
16.7
389
1000
4x3x0.75
0.6
0.2
14.4
1.5
18.2
464
1000
5x3x0.75
0.6
0.2
15.9
1.5
19.7
535
1000
6x3x0.75
0.6
0.2
17.4
1.5
21.2
607
1000
7x3x0.75
0.6
0.2
17.4
1.5
21.2
652
1000
10x3x0.75
0.6
0.2
22.4
1.7
26.6
898
500
12x3x0.75
0.6
0.2
23.2
1.7
27.4
1003
500
16x3x0.75
0.6
0.2
25.9
1.7
30.1
1233
500
20x3x0.75
0.6
0.2
29.1
1.8
33.5
1484
500
24x3x0.75
0.6
0.2
32.8
1.9
37.4
1779
500
30x3x0.75
0.6
0.2
34.9
1.9
39.5
2089
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
223
KCI
RE-Y(St)YBY , TiMF
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.2
8.0
1.3
11.4
212
1000
2x3x1
0.6
0.2
13.1
1.4
16.7
361
1000
3x3x1
0.6
0.2
13.9
1.5
17.7
437
1000
4x3x1
0.6
0.2
15.3
1.5
19.1
517
1000
5x3x1
0.6
0.2
16.8
1.5
20.6
598
1000
6x3x1
0.6
0.2
18.5
1.6
22.5
690
1000
7x3x1
0.6
0.2
18.5
1.6
22.5
745
1000
10x3x1
0.6
0.2
23.8
1.7
28.0
1017
500
12x3x1
0.6
0.2
24.7
1.7
28.9
1142
500
16x3x1
0.6
0.2
27.6
1.8
32.0
1425
500
20x3x1
0.6
0.2
31.0
1.8
35.4
1707
500
24x3x1
0.6
0.2
35.0
1.9
39.6
2046
500
30x3x1
0.6
0.5
37.2
2.0
43.2
2880
500
Instrument Cables
224
1x3x1.5
0.6
0.2
8.7
1.3
12.1
243
1000
2x3x1.5
0.6
0.2
14.3
1.5
18.1
428
1000
3x3x1.5
0.6
0.2
15.2
1.5
19.0
518
1000
4x3x1.5
0.6
0.2
16.8
1.5
20.6
619
1000
5x3x1.5
0.6
0.2
18.5
1.6
22.5
731
1000
6x3x1.5
0.6
0.2
20.3
1.6
24.3
837
1000
7x3x1.5
0.6
0.2
20.3
1.6
24.3
909
1000
10x3x1.5
0.6
0.2
26.3
1.7
30.5
1250
500
12x3x1.5
0.6
0.2
27.2
1.8
31.6
1426
500
16x3x1.5
0.6
0.2
30.5
1.8
34.9
1778
500
20x3x1.5
0.6
0.2
34.7
1.9
39.3
2194
500
24x3x1.5
0.6
0.5
38.7
2.1
44.9
3065
500
30x3x1.5
0.6
0.5
41.1
2.1
47.3
3580
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YBY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Tape
Thickness
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.2
10.0
1.4
13.6
309
1000
2x3x2.5
0.7
0.2
16.8
1.5
20.6
548
1000
3x3x2.5
0.7
0.2
18.0
1.6
22.0
686
1000
4x3x2.5
0.7
0.2
19.8
1.6
23.8
830
1000
5x3x2.5
0.7
0.2
21.9
1.7
26.1
987
500
6x3x2.5
0.7
0.2
24.1
1.7
28.3
1137
500
7x3x2.5
0.7
0.2
24.1
1.7
28.3
1245
500
10x3x2.5
0.7
0.2
31.3
1.9
35.9
1738
500
12x3x2.5
0.7
0.2
32.9
1.9
37.5
2014
500
16x3x2.5
0.7
0.5
36.8
2.0
42.8
2988
500
20x3x2.5
0.7
0.5
41.4
2.1
47.6
3589
500
24x3x2.5
0.7
0.5
46.6
2.3
53.2
4278
250
30x3x2.5
0.7
0.5
49.6
2.3
56.2
5030
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
225
KCI
RE-2X(St)YBY
Fire Resistant
EN 50288-7 (500 V)
RE-2X(St)YBY Multi-Core
RE-2X(St)YBY Multi-Pair
RE-2X(St)YRY Multi-Triple
RE-2X(St)YRY PiMF
RE-2X(St)YRY TiMF
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
RE-2X(St)HBH
Fire Resistant
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-2X(St)YBY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
228
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.2
7.4
1.3
10.8
165
1000
3x0.5
0.6
0.2
7.9
1.3
11.3
181
1000
4x0.5
0.6
0.2
8.5
1.3
11.9
202
1000
5x0.5
0.6
0.2
9.3
1.3
12.7
224
1000
6x0.5
0.6
0.2
10.0
1.4
13.6
252
1000
7x0.5
0.6
0.2
10.0
1.4
13.6
261
1000
8x0.5
0.6
0.2
11.6
1.4
15.2
297
1000
10x0.5
0.6
0.2
12.6
1.4
16.2
334
1000
12x0.5
0.6
0.2
13.0
1.4
16.6
360
1000
16x0.5
0.6
0.2
14.4
1.4
18.0
422
1000
20x0.5
0.6
0.2
16.0
1.5
19.8
495
1000
24x0.5
0.6
0.2
17.8
1.5
21.6
563
1000
30x0.5
0.6
0.2
18.8
1.5
22.6
638
1000
2x0.75
0.6
0.2
7.9
1.3
11.3
178
1000
3x0.75
0.6
0.2
8.3
1.3
11.7
198
1000
4x0.75
0.6
0.2
9.0
1.3
12.4
223
1000
5x0.75
0.6
0.2
9.8
1.3
13.2
249
1000
6x0.75
0.6
0.2
10.7
1.4
14.3
281
1000
7x0.75
0.6
0.2
10.7
1.4
14.3
294
1000
8x0.75
0.6
0.2
12.3
1.4
15.9
335
1000
10x0.75
0.6
0.2
13.4
1.4
17.0
379
1000
12x0.75
0.6
0.2
13.9
1.4
17.5
412
1000
16x0.75
0.6
0.2
15.4
1.5
19.2
495
1000
20x0.75
0.6
0.2
17.2
1.5
21.0
575
1000
24x0.75
0.6
0.2
19.0
1.5
22.8
658
1000
30x0.75
0.6
0.2
20.2
1.6
24.2
762
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
229
KCI
RE-2X(St)YRY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.2
8.2
1.3
11.6
190
1000
3x1
0.6
0.2
8.7
1.3
12.1
213
1000
4x1
0.6
0.2
9.5
1.3
12.9
242
1000
5x1
0.6
0.2
10.3
1.4
13.9
277
1000
6x1
0.6
0.2
11.2
1.4
14.8
307
1000
7x1
0.6
0.2
11.2
1.4
14.8
323
1000
8x1
0.6
0.2
13.0
1.4
16.6
369
1000
10x1
0.6
0.2
14.2
1.4
17.8
420
1000
12x1
0.6
0.2
14.6
1.4
18.2
459
1000
16x1
0.6
0.2
16.2
1.5
20.0
555
1000
20x1
0.6
0.2
18.1
1.5
21.9
649
1000
24x1
0.6
0.2
20.1
1.6
24.1
755
1000
30x1
0.6
0.2
21.3
1.6
25.3
868
500
Instrument Cables
230
2x1.5
0.6
0.2
8.8
1.3
12.2
212
1000
3x1.5
0.6
0.2
9.4
1.3
12.8
242
1000
4x1.5
0.6
0.2
10.2
1.4
13.8
283
1000
5x1.5
0.6
0.2
11.1
1.4
14.7
320
1000
6x1.5
0.6
0.2
12.1
1.4
15.7
358
1000
7x1.5
0.6
0.2
12.1
1.4
15.7
379
1000
8x1.5
0.6
0.2
14.1
1.4
17.7
435
1000
10x1.5
0.6
0.2
15.4
1.5
19.2
507
1000
12x1.5
0.6
0.2
15.9
1.5
19.7
558
1000
16x1.5
0.6
0.2
17.7
1.5
21.5
673
1000
20x1.5
0.6
0.2
19.7
1.6
23.7
803
1000
24x1.5
0.6
0.2
21.9
1.6
25.9
926
500
30x1.5
0.6
0.2
23.2
1.6
27.2
1076
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.2
10.1
1.4
13.7
262
1000
3x2.5
0.7
0.2
10.7
1.4
14.3
305
1000
4x2.5
0.7
0.2
11.7
1.4
15.3
354
1000
5x2.5
0.7
0.2
12.8
1.4
16.4
405
1000
6x2.5
0.7
0.2
14.0
1.4
17.6
457
1000
7x2.5
0.7
0.2
14.0
1.4
17.6
489
1000
8x2.5
0.7
0.2
16.3
1.5
20.1
570
1000
10x2.5
0.7
0.2
17.8
1.5
21.6
661
1000
12x2.5
0.7
0.2
18.5
1.5
22.3
736
1000
16x2.5
0.7
0.2
20.6
1.6
24.6
910
500
20x2.5
0.7
0.2
23.0
1.6
27.0
1082
500
24x2.5
0.7
0.2
25.6
1.7
29.8
1267
500
30x2.5
0.7
0.2
27.2
1.7
31.4
1487
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
231
KCI
RE-2X(St)YBY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Extruded PVC
Galvanized Steel Tapes
Extruded PVC
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
232
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.2
7.4
1.3
10.8
165
1000
2x2x0.5
0.6
0.2
10.8
1.4
14.4
246
1000
3x2x0.5
0.6
0.2
11.4
1.4
15.0
277
1000
4x2x0.5
0.6
0.2
12.5
1.4
16.1
315
1000
5x2x0.5
0.6
0.2
13.7
1.4
17.3
355
1000
6x2x0.5
0.6
0.2
15.0
1.5
18.8
403
1000
7x2x0.5
0.6
0.2
15.0
1.5
18.8
423
1000
10x2x0.5
0.6
0.2
19.2
1.5
23.0
555
1000
12x2x0.5
0.6
0.2
19.9
1.6
23.9
614
1000
16x2x0.5
0.6
0.2
22.2
1.6
26.2
732
500
20x2x0.5
0.6
0.2
24.8
1.7
29.0
867
500
24x2x0.5
0.6
0.2
27.7
1.7
31.9
996
500
30x2x0.5
0.6
0.2
29.4
1.7
33.6
1143
500
1x2x0.75
0.6
0.2
7.9
1.3
11.3
179
1000
2x2x0.75
0.6
0.2
11.4
1.4
15.0
271
1000
3x2x0.75
0.6
0.2
12.2
1.4
15.8
309
1000
4x2x0.75
0.6
0.2
13.4
1.4
17.0
355
1000
5x2x0.75
0.6
0.2
14.6
1.5
18.4
410
1000
6x2x0.75
0.6
0.2
16.0
1.5
19.8
459
1000
7x2x0.75
0.6
0.2
16.0
1.5
19.8
484
1000
10x2x0.75
0.6
0.2
20.6
1.6
24.6
651
500
12x2x0.75
0.6
0.2
21.3
1.6
25.3
714
500
16x2x0.75
0.6
0.2
23.8
1.6
27.8
860
500
20x2x0.75
0.6
0.2
26.7
1.7
30.9
1024
500
24x2x0.75
0.6
0.2
29.7
1.8
34.1
1194
500
30x2x0.75
0.6
0.2
31.6
1.8
36.0
1380
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
233
KCI
RE-2X(St)YRY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.2
8.2
1.3
11.6
191
1000
2x2x1
0.6
0.2
12.0
1.4
15.6
293
1000
3x2x1
0.6
0.2
12.8
1.4
16.4
337
1000
4x2x1
0.6
0.2
14.1
1.4
17.7
390
1000
5x2x1
0.6
0.2
15.4
1.5
19.2
452
1000
6x2x1
0.6
0.2
16.9
1.5
20.7
509
1000
7x2x1
0.6
0.2
16.9
1.5
20.7
541
1000
10x2x1
0.6
0.2
21.8
1.6
25.8
730
500
12x2x1
0.6
0.2
22.6
1.6
26.6
806
500
16x2x1
0.6
0.2
25.2
1.7
29.4
989
500
20x2x1
0.6
0.2
28.2
1.7
32.4
1170
500
24x2x1
0.6
0.2
31.5
1.8
35.9
1367
500
30x2x1
0.6
0.2
33.5
1.8
37.9
1591
500
Instrument Cables
234
1x2x1.5
0.6
0.2
8.8
1.3
12.2
213
1000
2x2x1.5
0.6
0.2
13.0
1.4
16.6
334
1000
3x2x1.5
0.6
0.2
13.9
1.4
17.5
392
1000
4x2x1.5
0.6
0.2
15.3
1.5
19.1
467
1000
5x2x1.5
0.6
0.2
16.8
1.5
20.6
536
1000
6x2x1.5
0.6
0.2
18.4
1.5
22.2
607
1000
7x2x1.5
0.6
0.2
18.4
1.5
22.2
650
1000
10x2x1.5
0.6
0.2
23.7
1.6
27.7
884
500
12x2x1.5
0.6
0.2
24.6
1.7
28.8
996
500
16x2x1.5
0.6
0.2
27.5
1.7
31.7
1221
500
20x2x1.5
0.6
0.2
30.9
1.8
35.3
1467
500
24x2x1.5
0.6
0.2
34.5
1.9
39.1
1720
500
30x2x1.5
0.6
0.2
37.1
1.9
41.7
2059
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.2
10.1
1.4
13.7
263
1000
2x2x2.5
0.7
0.2
15.0
1.5
18.8
424
1000
3x2x2.5
0.7
0.2
16.1
1.5
19.9
506
1000
4x2x2.5
0.7
0.2
17.7
1.5
21.5
601
1000
5x2x2.5
0.7
0.2
19.5
1.6
23.5
707
1000
6x2x2.5
0.7
0.2
21.4
1.6
25.4
807
500
7x2x2.5
0.7
0.2
21.4
1.6
25.4
871
500
10x2x2.5
0.7
0.2
27.8
1.8
32.2
1207
500
12x2x2.5
0.7
0.2
28.8
1.8
33.2
1356
500
16x2x2.5
0.7
0.2
32.3
1.9
36.9
1694
500
20x2x2.5
0.7
0.2
36.7
2.0
41.5
2086
500
24x2x2.5
0.7
0.5
41.0
2.1
47.2
2941
500
30x2x2.5
0.7
0.5
43.6
2.1
49.8
3413
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
235
KCI
RE-2X(St)YBY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Tapes
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
IEC 60331
Instrument Cables
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
236
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.2
7.9
1.3
11.3
182
1000
2x3x0.5
0.6
0.2
11.9
1.4
15.5
286
1000
3x3x0.5
0.6
0.2
12.7
1.4
16.3
328
1000
4x3x0.5
0.6
0.2
14.0
1.4
17.6
378
1000
5x3x0.5
0.6
0.2
15.3
1.5
19.1
438
1000
6x3x0.5
0.6
0.2
16.7
1.5
20.5
492
1000
7x3x0.5
0.6
0.2
16.7
1.5
20.5
521
1000
10x3x0.5
0.6
0.2
21.6
1.6
25.6
702
500
12x3x0.5
0.6
0.2
22.3
1.6
26.3
773
500
16x3x0.5
0.6
0.2
24.9
1.7
29.1
946
500
20x3x0.5
0.6
0.2
28.0
1.7
32.2
1117
500
24x3x0.5
0.6
0.2
31.2
1.8
35.6
1304
500
30x3x0.5
0.6
0.2
33.2
1.8
37.6
1513
500
1x3x0.75
0.6
0.2
8.3
1.3
11.7
199
1000
2x3x0.75
0.6
0.2
12.7
1.4
16.3
319
1000
3x3x0.75
0.6
0.2
13.5
1.4
17.1
371
1000
4x3x0.75
0.6
0.2
14.9
1.5
18.7
439
1000
5x3x0.75
0.6
0.2
16.4
1.5
20.2
503
1000
6x3x0.75
0.6
0.2
17.9
1.5
21.7
569
1000
7x3x0.75
0.6
0.2
17.9
1.5
21.7
607
1000
10x3x0.75
0.6
0.2
23.1
1.6
27.1
823
500
12x3x0.75
0.6
0.2
24.0
1.6
28.0
913
500
16x3x0.75
0.6
0.2
26.8
1.7
31.0
1127
500
20x3x0.75
0.6
0.2
30.1
1.8
34.5
1351
500
24x3x0.75
0.6
0.2
33.6
1.8
38.0
1568
500
30x3x0.75
0.6
0.2
36.1
1.9
40.7
1889
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
237
KCI
RE-2X(St)YBY
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.2
8.7
1.3
12.1
214
1000
2x3x1
0.6
0.2
13.4
1.4
17.0
347
1000
3x3x1
0.6
0.2
14.3
1.4
17.9
409
1000
4x3x1
0.6
0.2
15.7
1.5
19.5
489
1000
5x3x1
0.6
0.2
17.3
1.5
21.1
563
1000
6x3x1
0.6
0.2
18.9
1.5
22.7
639
1000
7x3x1
0.6
0.2
18.9
1.5
22.7
686
1000
10x3x1
0.6
0.2
24.5
1.6
28.5
934
500
12x3x1
0.6
0.2
25.4
1.7
29.6
1055
500
16x3x1
0.6
0.2
28.4
1.7
32.6
1296
500
20x3x1
0.6
0.2
31.9
1.8
36.3
1561
500
24x3x1
0.6
0.2
35.6
1.9
40.2
1831
500
30x3x1
0.6
0.2
38.3
1.9
42.9
2196
500
Instrument Cables
238
1x3x1.5
0.6
0.2
9.4
1.3
12.8
244
1000
2x3x1.5
0.6
0.2
14.5
1.5
18.3
410
1000
3x3x1.5
0.6
0.2
15.5
1.5
19.3
492
1000
4x3x1.5
0.6
0.2
17.1
1.5
20.9
584
1000
5x3x1.5
0.6
0.2
18.8
1.5
22.6
679
1000
6x3x1.5
0.6
0.2
20.6
1.6
24.6
785
500
7x3x1.5
0.6
0.2
20.6
1.6
24.6
849
500
10x3x1.5
0.6
0.2
26.7
1.7
30.9
1164
500
12x3x1.5
0.6
0.2
27.7
1.7
31.9
1310
500
16x3x1.5
0.6
0.2
31.0
1.8
35.4
1640
500
20x3x1.5
0.6
0.2
35.3
1.9
39.9
2022
500
24x3x1.5
0.6
0.5
39.3
2.0
45.3
2849
500
30x3x1.5
0.6
0.5
41.9
2.1
48.1
3330
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.2
10.7
1.4
14.3
307
1000
2x3x2.5
0.7
0.2
16.8
1.5
20.6
520
1000
3x3x2.5
0.7
0.2
18.0
1.5
21.8
638
1000
4x3x2.5
0.7
0.2
19.9
1.6
23.9
778
1000
5x3x2.5
0.7
0.2
21.9
1.6
25.9
912
500
6x3x2.5
0.7
0.2
24.1
1.7
28.3
1060
500
7x3x2.5
0.7
0.2
24.1
1.7
28.3
1157
500
10x3x2.5
0.7
0.2
31.4
1.8
35.8
1598
500
12x3x2.5
0.7
0.2
32.5
1.9
37.1
1827
500
16x3x2.5
0.7
0.2
36.8
2.0
41.6
2347
500
20x3x2.5
0.7
0.5
41.4
2.1
47.6
3343
500
24x3x2.5
0.7
0.5
46.3
2.2
52.7
3908
250
30x3x2.5
0.7
0.5
49.7
2.3
56.3
4665
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
239
KCI
RE-2X(St)YBY , PiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Extruded PVC
Galvanized Steel Tapes
Extruded PVC
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
240
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.2
7.8
1.3
11.2
180
1000
2x2x0.5
0.6
0.2
12.1
1.4
15.7
288
1000
3x2x0.5
0.6
0.2
12.9
1.4
16.5
329
1000
4x2x0.5
0.6
0.2
14.2
1.4
17.8
380
1000
5x2x0.5
0.6
0.2
15.5
1.5
19.3
439
1000
6x2x0.5
0.6
0.2
17.0
1.5
20.8
493
1000
7x2x0.5
0.6
0.2
17.0
1.5
20.8
521
1000
10x2x0.5
0.6
0.2
21.9
1.6
25.9
702
500
12x2x0.5
0.6
0.2
22.7
1.6
26.7
772
500
16x2x0.5
0.6
0.2
25.4
1.7
29.6
943
500
20x2x0.5
0.6
0.2
28.4
1.7
32.6
1112
500
24x2x0.5
0.6
0.2
31.7
1.8
36.1
1297
500
30x2x0.5
0.6
0.2
33.7
1.8
38.1
1503
500
1x2x0.75
0.6
0.2
8.2
1.3
11.6
194
1000
2x2x0.75
0.6
0.2
12.8
1.4
16.4
314
1000
3x2x0.75
0.6
0.2
13.7
1.4
17.3
364
1000
4x2x0.75
0.6
0.2
15.1
1.5
18.9
429
1000
5x2x0.75
0.6
0.2
16.5
1.5
20.3
490
1000
6x2x0.75
0.6
0.2
18.1
1.5
21.9
553
1000
7x2x0.75
0.6
0.2
18.1
1.5
21.9
587
1000
10x2x0.75
0.6
0.2
23.4
1.6
27.4
794
500
12x2x0.75
0.6
0.2
24.3
1.7
28.5
889
500
16x2x0.75
0.6
0.2
27.1
1.7
31.3
1079
500
20x2x0.75
0.6
0.2
30.4
1.8
34.8
1291
500
24x2x0.75
0.6
0.2
34.0
1.9
38.6
1509
500
30x2x0.75
0.6
0.2
36.5
1.9
41.1
1797
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
241
KCI
RE-2X(St)YBY , PiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.2
8.6
1.3
12.0
206
1000
2x2x1
0.6
0.2
13.5
1.4
17.1
337
1000
3x2x1
0.6
0.2
14.4
1.4
18.0
393
1000
4x2x1
0.6
0.2
15.8
1.5
19.6
467
1000
5x2x1
0.6
0.2
17.4
1.5
21.2
535
1000
6x2x1
0.6
0.2
19.1
1.5
22.9
606
1000
7x2x1
0.6
0.2
19.1
1.5
22.9
646
1000
10x2x1
0.6
0.2
24.7
1.7
28.9
889
500
12x2x1
0.6
0.2
25.6
1.7
29.8
986
500
16x2x1
0.6
0.2
28.6
1.7
32.8
1204
500
20x2x1
0.6
0.2
32.1
1.8
36.5
1445
500
24x2x1
0.6
0.2
36.3
1.9
40.9
1732
500
30x2x1
0.6
0.2
38.6
1.9
43.2
2022
500
Instrument Cables
242
1x2x1.5
0.6
0.2
9.2
1.3
12.6
230
1000
2x2x1.5
0.6
0.2
14.6
1.5
18.4
389
1000
3x2x1.5
0.6
0.2
15.5
1.5
19.3
459
1000
4x2x1.5
0.6
0.2
17.1
1.5
20.9
540
1000
5x2x1.5
0.6
0.2
18.9
1.5
22.7
623
1000
6x2x1.5
0.6
0.2
20.7
1.6
24.7
718
500
7x2x1.5
0.6
0.2
20.7
1.6
24.7
771
500
10x2x1.5
0.6
0.2
26.8
1.7
31.0
1052
500
12x2x1.5
0.6
0.2
27.8
1.7
32.0
1176
500
16x2x1.5
0.6
0.2
31.1
1.8
35.5
1461
500
20x2x1.5
0.6
0.2
35.4
1.9
40.0
1798
500
24x2x1.5
0.6
0.5
39.5
2.0
45.5
2581
500
30x2x1.5
0.6
0.5
42.0
2.1
48.2
2995
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.2
10.4
1.4
14.0
281
1000
2x2x2.5
0.7
0.2
16.8
1.5
20.6
477
1000
3x2x2.5
0.7
0.2
17.9
1.5
21.7
573
1000
4x2x2.5
0.7
0.2
19.8
1.6
23.8
692
1000
5x2x2.5
0.7
0.2
21.8
1.6
25.8
805
500
6x2x2.5
0.7
0.2
24.0
1.7
28.2
931
500
7x2x2.5
0.7
0.2
24.0
1.7
28.2
1006
500
10x2x2.5
0.7
0.2
31.2
1.8
35.6
1382
500
12x2x2.5
0.7
0.2
32.4
1.9
37.0
1570
500
16x2x2.5
0.7
0.2
36.7
2.0
41.5
2003
500
20x2x2.5
0.7
0.5
41.3
2.1
47.5
2912
500
24x2x2.5
0.7
0.5
46.1
2.2
52.5
3391
250
30x2x2.5
0.7
0.5
49.5
2.3
56.1
4019
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
243
KCI
RE-2X(St)YBY , TiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Blue,White,Red (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
244
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Tape
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.2
8.2
1.3
11.6
197
1000
2x3x0.5
0.6
0.2
13.4
1.4
17.0
331
1000
3x3x0.5
0.6
0.2
14.3
1.4
17.9
384
1000
4x3x0.5
0.6
0.2
15.8
1.5
19.6
455
1000
5x3x0.5
0.6
0.2
17.3
1.5
21.1
520
1000
6x3x0.5
0.6
0.2
19.0
1.5
22.8
588
1000
7x3x0.5
0.6
0.2
19.0
1.5
22.8
626
1000
10x3x0.5
0.6
0.2
24.6
1.7
28.8
859
500
12x3x0.5
0.6
0.2
25.5
1.7
29.7
951
500
16x3x0.5
0.6
0.2
28.5
1.7
32.7
1159
500
20x3x0.5
0.6
0.2
32.0
1.8
36.4
1388
500
24x3x0.5
0.6
0.2
36.1
1.9
40.7
1664
500
30x3x0.5
0.6
0.2
38.4
1.9
43.0
1937
500
1x3x0.75
0.6
0.2
8.7
1.3
12.1
215
1000
2x3x0.75
0.6
0.2
14.3
1.4
17.9
365
1000
3x3x0.75
0.6
0.2
15.2
1.5
19.0
437
1000
4x3x0.75
0.6
0.2
16.8
1.5
20.6
512
1000
5x3x0.75
0.6
0.2
18.5
1.5
22.3
589
1000
6x3x0.75
0.6
0.2
20.3
1.6
24.3
678
1000
7x3x0.75
0.6
0.2
20.3
1.6
24.3
725
1000
10x3x0.75
0.6
0.2
26.3
1.7
30.5
987
500
12x3x0.75
0.6
0.2
27.2
1.7
31.4
1099
500
16x3x0.75
0.6
0.2
30.5
1.8
34.9
1362
500
20x3x0.75
0.6
0.2
34.3
1.9
38.9
1636
500
24x3x0.75
0.6
0.2
38.7
2.0
43.5
1960
500
30x3x0.75
0.6
0.5
41.1
2.0
47.1
2786
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
245
KCI
RE-2X(St)YBY , TiMF
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.2
9.1
1.3
12.5
230
1000
2x3x1
0.6
0.2
15.0
1.5
18.8
403
1000
3x3x1
0.6
0.2
16.0
1.5
19.8
477
1000
4x3x1
0.6
0.2
17.7
1.5
21.5
563
1000
5x3x1
0.6
0.2
19.5
1.5
23.3
651
1000
6x3x1
0.6
0.2
21.4
1.6
25.4
751
500
7x3x1
0.6
0.2
21.4
1.6
25.4
808
500
10x3x1
0.6
0.2
27.7
1.7
31.9
1104
500
12x3x1
0.6
0.2
28.8
1.7
33.0
1236
500
16x3x1
0.6
0.2
32.2
1.8
36.6
1539
500
20x3x1
0.6
0.2
36.6
1.9
41.2
1895
500
24x3x1
0.6
0.5
40.9
2.0
46.9
2711
500
30x3x1
0.6
0.5
43.5
2.1
49.7
3151
500
Instrument Cables
246
1x3x1.5
0.6
0.2
9.7
1.4
13.3
266
1000
2x3x1.5
0.6
0.2
16.2
1.5
20.0
462
1000
3x3x1.5
0.6
0.2
17.3
1.5
21.1
556
1000
4x3x1.5
0.6
0.2
19.2
1.6
23.2
672
1000
5x3x1.5
0.6
0.2
21.1
1.6
25.1
782
500
6x3x1.5
0.6
0.2
23.2
1.6
27.2
895
500
7x3x1.5
0.6
0.2
23.2
1.6
27.2
969
500
10x3x1.5
0.6
0.2
30.2
1.8
34.6
1345
500
12x3x1.5
0.6
0.2
31.3
1.8
35.7
1515
500
16x3x1.5
0.6
0.2
35.4
1.9
40.0
1937
500
20x3x1.5
0.6
0.5
39.8
2.0
45.8
2817
500
24x3x1.5
0.6
0.5
44.5
2.1
50.7
3282
250
30x3x1.5
0.6
0.5
47.4
2.2
53.8
3840
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YBY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
mm
Overall
Diameter
Diameter Under
Armour
mm2
Sheath thickness
Armour Wire
Diameter
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
0.2
11.1
1.4
14.7
325
1000
2x3x2.5
0.7
0.2
18.7
1.6
22.7
587
1000
3x3x2.5
0.7
0.2
20.1
1.6
24.1
719
1000
4x3x2.5
0.7
0.2
22.2
1.6
26.2
867
500
5x3x2.5
0.7
0.2
24.5
1.7
28.7
1029
500
6x3x2.5
0.7
0.2
27.0
1.7
31.2
1183
500
7x3x2.5
0.7
0.2
27.0
1.7
31.2
1292
500
10x3x2.5
0.7
0.2
35.6
1.9
40.2
1840
500
12x3x2.5
0.7
0.2
36.9
2.0
41.7
2099
500
16x3x2.5
0.7
0.5
41.4
2.1
47.6
3137
500
20x3x2.5
0.7
0.5
46.9
2.2
53.3
3813
250
24x3x2.5
0.7
0.5
52.5
2.3
59.1
4454
250
30x3x2.5
0.7
0.5
55.8
2.4
62.6
5242
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
247
KCI
RE-Y(St)YKYRY
EN 50288-7 (500 V)
RE-Y(St)YKYRY Multi-Core
RE-Y(St)YKYRY Multi-Pair
RE-Y(St)YKYRY Multi-Triple
RE-Y(St)YKYRY PiMF
RE-Y(St)YKYRY TiMF
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-Y(St)YKYRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
250
PVC
Core (Multi-Core Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
8.3
0.9
8.5
1.4
13.1
525
1000
3x0.5
0.6
0.9
8.6
0.9
8.8
1.4
13.4
552
1000
4x0.5
0.6
0.9
9.2
0.9
9.4
1.4
14.0
593
1000
5x0.5
0.6
0.9
9.8
0.9
10.0
1.4
14.6
635
1000
6x0.5
0.6
0.9
10.4
0.9
10.6
1.4
15.2
679
1000
7x0.5
0.6
0.9
10.4
0.9
10.6
1.4
15.2
687
1000
8x0.5
0.6
1.0
11.8
0.9
11.8
1.4
16.4
802
1000
10x0.5
0.6
1.0
12.7
0.9
12.7
1.5
17.5
878
1000
12x0.5
0.6
1.0
13.0
0.9
13.0
1.5
17.8
914
1000
16x0.5
0.6
1.0
14.2
0.9
14.2
1.5
19.0
1013
1000
20x0.5
0.6
1.0
15.5
0.9
15.5
1.5
20.3
1129
1000
24x0.5
0.6
1.1
17.1
0.9
16.9
1.6
21.9
1304
1000
30x0.5
0.6
1.1
17.9
1.25
17.7
1.6
23.4
1552
1000
2x0.75
0.6
0.9
8.7
0.9
8.9
1.4
13.5
556
1000
3x0.75
0.6
0.9
9.1
0.9
9.3
1.4
13.9
587
1000
4x0.75
0.6
0.9
9.7
0.9
9.9
1.4
14.5
633
1000
5x0.75
0.6
0.9
10.3
0.9
10.5
1.4
15.1
681
1000
6x0.75
0.6
0.9
11.0
0.9
11.2
1.4
15.8
736
1000
7x0.75
0.6
0.9
11.0
0.9
11.2
1.4
15.8
747
1000
8x0.75
0.6
1.0
12.6
0.9
12.6
1.5
17.4
881
1000
10x0.75
0.6
1.0
13.5
0.9
13.5
1.5
18.3
959
1000
12x0.75
0.6
1.0
13.9
0.9
13.9
1.5
18.7
1009
1000
16x0.75
0.6
1.0
15.1
0.9
15.1
1.5
19.9
1130
1000
20x0.75
0.6
1.1
16.8
0.9
16.6
1.6
21.6
1319
1000
24x0.75
0.6
1.1
18.3
1.25
18.1
1.6
23.8
1609
1000
30x0.75
0.6
1.1
19.3
1.25
19.1
1.6
24.8
1743
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
251
KCI
RE-Y(St)YKYRY
Diameter Under
Armour
mm
mm
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
9.1
0.9
9.3
1.4
13.9
577
1000
3x1
0.6
0.9
9.5
0.9
9.7
1.4
14.3
618
1000
4x1
0.6
0.9
10.1
0.9
10.3
1.4
14.9
668
1000
5x1
0.6
0.9
10.8
0.9
11.0
1.4
15.6
720
1000
6x1
0.6
1.0
11.8
0.9
11.8
1.4
16.4
810
1000
7x1
0.6
1.0
11.8
0.9
11.8
1.4
16.4
825
1000
8x1
0.6
1.0
13.3
0.9
13.3
1.5
18.1
935
1000
10x1
0.6
1.0
14.2
0.9
14.2
1.5
19.0
1027
1000
12x1
0.6
1.0
14.6
0.9
14.6
1.5
19.4
1078
1000
16x1
0.6
1.1
16.2
0.9
16.0
1.5
20.8
1262
1000
20x1
0.6
1.1
17.8
1.25
17.6
1.6
23.3
1562
1000
24x1
0.6
1.1
19.4
1.25
19.2
1.6
24.9
1737
1000
30x1
0.6
1.2
20.6
1.25
20.2
1.7
26.1
1972
1000
Instrument Cables
252
2x1.5
0.6
0.9
9.7
0.9
9.9
1.4
14.5
628
1000
3x1.5
0.6
0.9
10.1
0.9
10.3
1.4
14.9
676
1000
4x1.5
0.6
0.9
10.8
0.9
11.0
1.4
15.6
736
1000
5x1.5
0.6
1.0
11.8
0.9
11.8
1.4
16.4
840
1000
6x1.5
0.6
1.0
12.7
0.9
12.7
1.5
17.5
914
1000
7x1.5
0.6
1.0
12.7
0.9
12.7
1.5
17.5
934
1000
8x1.5
0.6
1.0
14.3
0.9
14.3
1.5
19.1
1058
1000
10x1.5
0.6
1.0
15.4
0.9
15.4
1.5
20.2
1167
1000
12x1.5
0.6
1.1
16.1
0.9
15.9
1.5
20.7
1282
1000
16x1.5
0.6
1.1
17.6
1.25
17.4
1.6
23.1
1604
1000
20x1.5
0.6
1.1
19.4
1.25
19.2
1.6
24.9
1807
1000
24x1.5
0.6
1.2
21.4
1.25
21.0
1.7
26.9
2101
1000
30x1.5
0.6
1.2
22.6
1.25
22.2
1.7
28.1
2300
1000
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
10.9
0.9
11.1
1.4
15.7
727
1000
3x2.5
0.7
1.0
11.7
0.9
11.7
1.4
16.3
828
1000
4x2.5
0.7
1.0
12.5
0.9
12.5
1.5
17.3
921
1000
5x2.5
0.7
1.0
13.5
0.9
13.5
1.5
18.3
1010
1000
6x2.5
0.7
1.0
14.5
0.9
14.5
1.5
19.3
1108
1000
7x2.5
0.7
1.0
14.5
0.9
14.5
1.5
19.3
1140
1000
8x2.5
0.7
1.1
16.8
0.9
16.6
1.6
21.6
1353
1000
10x2.5
0.7
1.1
18.1
1.25
17.9
1.6
23.6
1643
1000
12x2.5
0.7
1.1
18.7
1.25
18.5
1.6
24.2
1753
1000
16x2.5
0.7
1.2
20.7
1.25
20.3
1.7
26.2
2082
1000
20x2.5
0.7
1.2
22.9
1.25
22.5
1.7
28.4
2368
1000
24x2.5
0.7
1.3
25.3
1.25
24.7
1.8
30.8
2751
500
30x2.5
0.7
1.3
26.7
1.25
26.1
1.8
32.2
3057
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
253
KCI
RE-Y(St)YKYRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
254
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
8.3
0.9
8.5
1.4
13.1
526
1000
2x2x0.5
0.6
0.9
11.0
0.9
11.2
1.4
15.8
695
1000
3x2x0.5
0.6
1.0
11.7
0.9
11.7
1.4
16.3
775
1000
4x2x0.5
0.6
1.0
12.6
0.9
12.6
1.5
17.4
853
1000
5x2x0.5
0.6
1.0
13.6
0.9
13.6
1.5
18.4
927
1000
6x2x0.5
0.6
1.0
14.6
0.9
14.6
1.5
19.4
1010
1000
7x2x0.5
0.6
1.0
14.6
0.9
14.6
1.5
19.4
1027
1000
10x2x0.5
0.6
1.1
18.3
1.25
18.1
1.6
23.8
1492
1000
12x2x0.5
0.6
1.1
18.8
1.25
18.6
1.6
24.3
1563
1000
16x2x0.5
0.6
1.2
20.9
1.25
20.5
1.7
26.4
1830
1000
20x2x0.5
0.6
1.2
23.0
1.25
22.6
1.7
28.5
2057
1000
24x2x0.5
0.6
1.3
25.6
1.25
25.0
1.8
31.1
2387
500
30x2x0.5
0.6
1.3
27.0
1.25
26.4
1.8
32.5
2597
500
1x2x0.75
0.6
0.9
8.7
0.9
8.9
1.4
13.5
556
1000
2x2x0.75
0.6
1.0
11.9
0.9
11.9
1.4
16.5
786
1000
3x2x0.75
0.6
1.0
12.5
0.9
12.5
1.5
17.3
853
1000
4x2x0.75
0.6
1.0
13.5
0.9
13.5
1.5
18.3
935
1000
5x2x0.75
0.6
1.0
14.5
0.9
14.5
1.5
19.3
1025
1000
6x2x0.75
0.6
1.1
15.9
0.9
15.7
1.5
20.5
1161
1000
7x2x0.75
0.6
1.1
15.9
0.9
15.7
1.5
20.5
1185
1000
10x2x0.75
0.6
1.1
19.6
1.25
19.4
1.6
25.1
1657
1000
12x2x0.75
0.6
1.2
20.4
1.25
20.0
1.7
25.9
1814
1000
16x2x0.75
0.6
1.2
22.5
1.25
22.1
1.7
28.0
2061
1000
20x2x0.75
0.6
1.3
25.1
1.25
24.5
1.8
30.6
2420
500
24x2x0.75
0.6
1.3
27.6
1.25
27.0
1.8
33.1
2709
500
30x2x0.75
0.6
1.4
29.4
1.25
28.6
1.8
34.7
3051
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
255
KCI
RE-Y(St)YKYRY
Diameter Under
Armour
mm
mm
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
9.1
0.9
9.3
1.4
13.9
578
1000
2x2x1
0.6
1.0
12.5
0.9
12.5
1.5
17.3
833
1000
3x2x1
0.6
1.0
13.1
0.9
13.1
1.5
17.9
901
1000
4x2x1
0.6
1.0
14.2
0.9
14.2
1.5
19.0
991
1000
5x2x1
0.6
1.0
15.3
0.9
15.3
1.5
20.1
1090
1000
6x2x1
0.6
1.1
16.7
0.9
16.5
1.5
21.3
1242
1000
7x2x1
0.6
1.1
16.7
0.9
16.5
1.5
21.3
1272
1000
10x2x1
0.6
1.2
21.0
1.25
20.6
1.7
26.5
1859
1000
12x2x1
0.6
1.2
21.7
1.25
21.3
1.7
27.2
1960
1000
16x2x1
0.6
1.2
23.9
1.25
23.5
1.7
29.4
2237
500
20x2x1
0.6
1.3
26.7
1.25
26.1
1.8
32.2
2631
500
24x2x1
0.6
1.4
29.6
1.25
28.8
1.8
34.9
3047
500
30x2x1
0.6
1.4
31.3
1.6
30.5
1.9
37.5
3599
500
Instrument Cables
256
1x2x1.5
0.6
0.9
9.7
0.9
9.9
1.4
14.5
628
1000
2x2x1.5
0.6
1.0
13.4
0.9
13.4
1.5
18.2
923
1000
3x2x1.5
0.6
1.0
14.2
0.9
14.2
1.5
19.0
1007
1000
4x2x1.5
0.6
1.0
15.4
0.9
15.4
1.5
20.2
1121
1000
5x2x1.5
0.6
1.1
16.8
0.9
16.6
1.6
21.6
1298
1000
6x2x1.5
0.6
1.1
18.2
1.25
18.0
1.6
23.7
1565
1000
7x2x1.5
0.6
1.1
18.2
1.25
18.0
1.6
23.7
1607
1000
10x2x1.5
0.6
1.2
23.0
1.25
22.6
1.7
28.5
2134
1000
12x2x1.5
0.6
1.2
23.7
1.25
23.3
1.7
29.2
2274
500
16x2x1.5
0.6
1.3
26.4
1.25
25.8
1.8
31.9
2715
500
20x2x1.5
0.6
1.4
29.5
1.25
28.7
1.9
35.0
3205
500
24x2x1.5
0.6
1.4
32.5
1.6
31.7
1.9
38.7
3843
500
30x2x1.5
0.6
1.5
34.6
1.6
34.0
2.0
41.2
4434
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
10.9
0.9
11.1
1.4
15.7
728
1000
2x2x2.5
0.7
1.1
15.7
0.9
15.5
1.5
20.3
1153
1000
3x2x2.5
0.7
1.1
16.6
0.9
16.4
1.6
21.4
1284
1000
4x2x2.5
0.7
1.1
18.0
1.25
17.8
1.6
23.5
1580
1000
5x2x2.5
0.7
1.2
19.8
1.25
19.4
1.7
25.3
1830
1000
6x2x2.5
0.7
1.2
21.5
1.25
21.1
1.7
27.0
2020
1000
7x2x2.5
0.7
1.2
21.5
1.25
21.1
1.7
27.0
2085
1000
10x2x2.5
0.7
1.3
27.3
1.25
26.7
1.8
32.8
2789
500
12x2x2.5
0.7
1.4
28.4
1.25
27.6
1.8
33.7
3072
500
16x2x2.5
0.7
1.4
31.4
1.6
30.6
1.9
37.6
3815
500
20x2x2.5
0.7
1.5
35.5
1.6
34.9
2.0
42.1
4618
500
24x2x2.5
0.7
1.6
39.4
38.6
2.1
46.8
5699
500
30x2x2.5
0.7
1.7
41.9
40.9
2.2
49.3
6462
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
257
KCI
RE-Y(St)YKYRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
PVC
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
Metal Sheath
Lead Sheath (Cover)
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC
+70 oC
IEC 60332-1
Instrument Cables
Criteria
258
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
8.6
0.9
8.8
1.4
13.4
553
1000
2x3x0.5
0.6
1.0
12.1
0.9
12.1
1.5
16.9
810
1000
3x3x0.5
0.6
1.0
12.8
0.9
12.8
1.5
17.6
874
1000
4x3x0.5
0.6
1.0
13.8
0.9
13.8
1.5
18.6
959
1000
5x3x0.5
0.6
1.0
14.9
0.9
14.9
1.5
19.7
1053
1000
6x3x0.5
0.6
1.1
16.3
0.9
16.1
1.5
20.9
1198
1000
7x3x0.5
0.6
1.1
16.3
0.9
16.1
1.5
20.9
1225
1000
10x3x0.5
0.6
1.2
20.4
1.25
20.0
1.6
25.7
1768
1000
12x3x0.5
0.6
1.2
21.0
1.25
20.6
1.7
26.5
1883
1000
16x3x0.5
0.6
1.2
23.1
1.25
22.7
1.7
28.6
2142
1000
20x3x0.5
0.6
1.3
25.8
1.25
25.2
1.8
31.3
2507
500
24x3x0.5
0.6
1.3
28.4
1.25
27.8
1.8
33.9
2819
500
30x3x0.5
0.6
1.4
30.2
1.6
29.4
1.9
36.4
3417
500
1x3x0.75
0.6
0.9
9.1
0.9
9.3
1.4
13.9
588
1000
2x3x0.75
0.6
1.0
12.9
0.9
12.9
1.5
17.7
877
1000
3x3x0.75
0.6
1.0
13.6
0.9
13.6
1.5
18.4
958
1000
4x3x0.75
0.6
1.0
14.7
0.9
14.7
1.5
19.5
1058
1000
5x3x0.75
0.6
1.1
16.1
0.9
15.9
1.5
20.7
1215
1000
6x3x0.75
0.6
1.1
17.4
1.25
17.2
1.6
22.9
1481
1000
7x3x0.75
0.6
1.1
17.4
1.25
17.2
1.6
22.9
1517
1000
10x3x0.75
0.6
1.2
22.0
1.25
21.6
1.7
27.5
2000
1000
12x3x0.75
0.6
1.2
22.6
1.25
22.2
1.7
28.1
2116
1000
16x3x0.75
0.6
1.3
25.2
1.25
24.6
1.8
30.7
2521
500
20x3x0.75
0.6
1.3
27.9
1.25
27.3
1.8
33.4
2867
500
24x3x0.75
0.6
1.4
31.0
1.6
30.2
1.9
37.2
3574
500
30x3x0.75
0.6
1.5
33.0
1.6
32.4
2.0
39.6
4099
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
259
KCI
RE-Y(St)YKYRY
Diameter Under
Armour
mm
mm
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
9.5
0.9
9.7
1.4
14.3
619
1000
2x3x1
0.6
1.0
13.6
0.9
13.6
1.5
18.4
932
1000
3x3x1
0.6
1.0
14.3
0.9
14.3
1.5
19.1
1019
1000
4x3x1
0.6
1.0
15.5
0.9
15.5
1.5
20.3
1135
1000
5x3x1
0.6
1.1
17.0
0.9
16.8
1.6
21.8
1315
1000
6x3x1
0.6
1.1
18.4
1.25
18.2
1.6
23.9
1589
1000
7x3x1
0.6
1.1
18.4
1.25
18.2
1.6
23.9
1634
1000
10x3x1
0.6
1.2
23.3
1.25
22.9
1.7
28.8
2169
1000
12x3x1
0.6
1.2
24.0
1.25
23.6
1.7
29.5
2315
500
16x3x1
0.6
1.3
26.8
1.25
26.2
1.8
32.3
2767
500
20x3x1
0.6
1.4
29.9
1.25
29.1
1.8
35.2
3254
500
24x3x1
0.6
1.4
33.0
1.6
32.2
1.9
39.2
3923
500
30x3x1
0.6
1.5
35.1
1.6
34.5
2.0
41.7
4531
500
Instrument Cables
260
1x3x1.5
0.6
0.9
10.1
0.9
10.3
1.4
14.9
677
1000
2x3x1.5
0.6
1.0
14.7
0.9
14.7
1.5
19.5
1041
1000
3x3x1.5
0.6
1.1
15.7
0.9
15.5
1.5
20.3
1203
1000
4x3x1.5
0.6
1.1
17.1
0.9
16.9
1.6
21.9
1357
1000
5x3x1.5
0.6
1.1
18.6
1.25
18.4
1.6
24.1
1654
1000
6x3x1.5
0.6
1.2
20.3
1.25
19.9
1.7
25.8
1900
1000
7x3x1.5
0.6
1.2
20.3
1.25
19.9
1.7
25.8
1963
1000
10x3x1.5
0.6
1.3
25.7
1.25
25.1
1.8
31.2
2618
500
12x3x1.5
0.6
1.3
26.6
1.25
26.0
1.8
32.1
2808
500
16x3x1.5
0.6
1.4
29.6
1.25
28.8
1.9
35.1
3379
500
20x3x1.5
0.6
1.5
33.1
1.6
32.5
2.0
39.7
4292
500
24x3x1.5
0.6
1.6
37.2
1.6
36.4
2.1
43.8
5047
500
30x3x1.5
0.6
1.6
39.3
38.5
2.1
46.7
5962
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.7
1.0
11.7
0.9
11.7
1.4
16.3
829
1000
2x3x2.5
0.7
1.1
17.2
1.25
17.0
1.6
22.7
1457
1000
3x3x2.5
0.7
1.1
18.2
1.25
18.0
1.6
23.7
1633
1000
4x3x2.5
0.7
1.2
20.1
1.25
19.7
1.7
25.6
1911
1000
5x3x2.5
0.7
1.2
21.9
1.25
21.5
1.7
27.4
2149
1000
6x3x2.5
0.7
1.3
24.0
1.25
23.4
1.7
29.3
2456
500
7x3x2.5
0.7
1.3
24.0
1.25
23.4
1.7
29.3
2553
500
10x3x2.5
0.7
1.4
30.6
1.6
29.8
1.9
36.8
3688
500
12x3x2.5
0.7
1.4
31.6
1.6
30.8
1.9
37.8
3975
500
16x3x2.5
0.7
1.5
35.6
1.6
35.0
2.0
42.2
4903
500
20x3x2.5
0.7
1.6
39.8
39.0
2.2
47.4
6161
500
24x3x2.5
0.7
1.7
44.3
43.3
2.3
51.9
7140
500
30x3x2.5
0.7
1.8
47.1
46.3
2.3
54.9
8196
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
261
KCI
RE-Y(St)YKYRY , PiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+70 oC
Instrument Cables
262
PVC
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY , PiMF
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
8.6
0.9
8.8
1.4
13.4
553
1000
2x2x0.5
0.6
1.0
12.4
0.9
12.4
1.5
17.2
825
1000
3x2x0.5
0.6
1.0
13.0
0.9
13.0
1.5
17.8
889
1000
4x2x0.5
0.6
1.0
14.1
0.9
14.1
1.5
18.9
975
1000
5x2x0.5
0.6
1.0
15.2
0.9
15.2
1.5
20.0
1070
1000
6x2x0.5
0.6
1.1
16.6
0.9
16.4
1.5
21.2
1217
1000
7x2x0.5
0.6
1.1
16.6
0.9
16.4
1.5
21.2
1243
1000
10x2x0.5
0.6
1.2
20.9
1.25
20.5
1.7
26.4
1808
1000
12x2x0.5
0.6
1.2
21.6
1.25
21.2
1.7
27.1
1911
1000
16x2x0.5
0.6
1.2
23.7
1.25
23.3
1.7
29.2
2172
500
20x2x0.5
0.6
1.3
26.5
1.25
25.9
1.8
32.0
2549
500
24x2x0.5
0.6
1.4
29.4
1.25
28.6
1.8
34.7
2939
500
30x2x0.5
0.6
1.4
31.1
1.6
30.3
1.9
37.3
3476
500
1x2x0.75
0.6
0.9
9.1
0.9
9.3
1.4
13.9
584
1000
2x2x0.75
0.6
1.0
13.1
0.9
13.1
1.5
17.9
885
1000
3x2x0.75
0.6
1.0
13.9
0.9
13.9
1.5
18.7
959
1000
4x2x0.75
0.6
1.0
15.0
0.9
15.0
1.5
19.8
1061
1000
5x2x0.75
0.6
1.1
16.4
0.9
16.2
1.5
21.0
1217
1000
6x2x0.75
0.6
1.1
17.8
1.25
17.6
1.6
23.3
1476
1000
7x2x0.75
0.6
1.1
17.8
1.25
17.6
1.6
23.3
1508
1000
10x2x0.75
0.6
1.2
22.4
1.25
22.0
1.7
27.9
1998
1000
12x2x0.75
0.6
1.2
23.1
1.25
22.7
1.7
28.6
2117
1000
16x2x0.75
0.6
1.3
25.7
1.25
25.1
1.8
31.2
2503
500
20x2x0.75
0.6
1.4
28.7
1.25
27.9
1.8
34.0
2934
500
24x2x0.75
0.6
1.4
31.7
1.6
30.9
1.9
37.9
3545
500
30x2x0.75
0.6
1.5
33.7
1.6
33.1
2.0
40.3
4054
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
263
KCI
RE-Y(St)YKYRY , PiMF
Diameter Under
Armour
mm
mm
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
9.4
0.9
9.6
1.4
14.2
611
1000
2x2x1
0.6
1.0
13.8
0.9
13.8
1.5
18.6
928
1000
3x2x1
0.6
1.0
14.5
0.9
14.5
1.5
19.3
1015
1000
4x2x1
0.6
1.0
15.8
0.9
15.8
1.5
20.6
1126
1000
5x2x1
0.6
1.1
17.3
0.9
17.1
1.6
22.1
1302
1000
6x2x1
0.6
1.1
18.7
1.25
18.5
1.6
24.2
1576
1000
7x2x1
0.6
1.1
18.7
1.25
18.5
1.6
24.2
1615
1000
10x2x1
0.6
1.2
23.7
1.25
23.3
1.7
29.2
2137
500
12x2x1
0.6
1.2
24.4
1.25
24.0
1.7
29.9
2271
500
16x2x1
0.6
1.3
27.2
1.25
26.6
1.8
32.7
2702
500
20x2x1
0.6
1.4
30.4
1.6
29.6
1.9
36.6
3412
500
24x2x1
0.6
1.5
33.8
1.6
33.2
2.0
40.4
3987
500
30x2x1
0.6
1.5
35.7
1.6
35.1
2.0
42.3
4399
500
Instrument Cables
264
1x2x1.5
0.6
0.9
10.0
0.9
10.2
1.4
14.8
657
1000
2x2x1.5
0.6
1.0
14.8
0.9
14.8
1.5
19.6
1029
1000
3x2x1.5
0.6
1.1
15.9
0.9
15.7
1.5
20.5
1175
1000
4x2x1.5
0.6
1.1
17.3
0.9
17.1
1.6
22.1
1324
1000
5x2x1.5
0.6
1.1
18.7
1.25
18.5
1.6
24.2
1614
1000
6x2x1.5
0.6
1.2
20.5
1.25
20.1
1.7
26.0
1841
1000
7x2x1.5
0.6
1.2
20.5
1.25
20.1
1.7
26.0
1892
1000
10x2x1.5
0.6
1.3
26.0
1.25
25.4
1.8
31.5
2526
500
12x2x1.5
0.6
1.3
26.9
1.25
26.3
1.8
32.4
2693
500
16x2x1.5
0.6
1.4
29.9
1.25
29.1
1.9
35.4
3220
500
20x2x1.5
0.6
1.5
33.4
1.6
32.8
2.0
40.0
4080
500
24x2x1.5
0.6
1.6
37.6
1.6
36.8
2.1
44.2
4809
500
30x2x1.5
0.6
1.6
39.7
38.9
2.1
47.1
5639
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY , PiMF
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.7
1.0
11.5
0.9
11.5
1.4
16.1
799
1000
2x2x2.5
0.7
1.1
17.3
1.25
17.1
1.6
22.8
1413
1000
3x2x2.5
0.7
1.1
18.3
1.25
18.1
1.6
23.8
1567
1000
4x2x2.5
0.7
1.2
20.1
1.25
19.7
1.7
25.6
1833
1000
5x2x2.5
0.7
1.2
21.9
1.25
21.5
1.7
27.4
2038
1000
6x2x2.5
0.7
1.3
24.0
1.25
23.4
1.7
29.3
2323
500
7x2x2.5
0.7
1.3
24.0
1.25
23.4
1.7
29.3
2399
500
10x2x2.5
0.7
1.4
30.6
1.6
29.8
1.9
36.8
3467
500
12x2x2.5
0.7
1.4
31.6
1.6
30.8
1.9
37.8
3708
500
16x2x2.5
0.7
1.5
35.7
1.6
35.1
2.0
42.3
4548
500
20x2x2.5
0.7
1.6
39.9
39.1
2.2
47.5
5717
500
24x2x2.5
0.7
1.8
44.6
43.8
2.3
52.4
6810
500
30x2x2.5
0.7
1.8
47.2
46.4
2.3
55.0
7530
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
265
KCI
RE-Y(St)YKYRY , TiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
Instrument Cables
+70 oC
PVC
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Extruded PVC
Lead Sheath (Cover)
Extruded PVC
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
100
MOhm x
km
Mutual capacitance
max.
250
nF/km
L/R (ratio)
max.
266
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY , TiMF
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
9.0
0.9
9.2
1.4
13.8
581
1000
2x3x0.5
0.6
1.0
13.5
0.9
13.5
1.5
18.3
905
1000
3x3x0.5
0.6
1.0
14.2
0.9
14.2
1.5
19.0
987
1000
4x3x0.5
0.6
1.0
15.4
0.9
15.4
1.5
20.2
1088
1000
5x3x0.5
0.6
1.1
16.9
0.9
16.7
1.6
21.7
1263
1000
6x3x0.5
0.6
1.1
18.3
1.25
18.1
1.6
23.8
1527
1000
7x3x0.5
0.6
1.1
18.3
1.25
18.1
1.6
23.8
1562
1000
10x3x0.5
0.6
1.2
23.1
1.25
22.7
1.7
28.6
2055
1000
12x3x0.5
0.6
1.2
23.8
1.25
23.4
1.7
29.3
2181
500
16x3x0.5
0.6
1.3
26.5
1.25
25.9
1.8
32.0
2592
500
20x3x0.5
0.6
1.4
29.6
1.25
28.8
1.8
34.9
3039
500
24x3x0.5
0.6
1.4
32.7
1.6
31.9
1.9
38.9
3677
500
30x3x0.5
0.6
1.5
34.8
1.6
34.2
2.0
41.4
4208
500
1x3x0.75
0.6
0.9
9.4
0.9
9.6
1.4
14.2
622
1000
2x3x0.75
0.6
1.0
14.3
0.9
14.3
1.5
19.1
982
1000
3x3x0.75
0.6
1.0
15.1
0.9
15.1
1.5
19.9
1077
1000
4x3x0.75
0.6
1.1
16.6
0.9
16.4
1.6
21.4
1257
1000
5x3x0.75
0.6
1.1
18.1
1.25
17.9
1.6
23.6
1528
1000
6x3x0.75
0.6
1.1
19.6
1.25
19.4
1.6
25.1
1682
1000
7x3x0.75
0.6
1.1
19.6
1.25
19.4
1.6
25.1
1727
1000
10x3x0.75
0.6
1.3
25.0
1.25
24.4
1.8
30.5
2374
500
12x3x0.75
0.6
1.3
25.8
1.25
25.2
1.8
31.3
2526
500
16x3x0.75
0.6
1.4
28.7
1.25
27.9
1.8
34.0
3001
500
20x3x0.75
0.6
1.4
31.9
1.6
31.1
1.9
38.1
3672
500
24x3x0.75
0.6
1.5
35.8
1.6
35.2
2.0
42.4
4377
500
30x3x0.75
0.6
1.6
38.1
1.6
37.3
2.1
44.7
4965
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
267
KCI
RE-Y(St)YKYRY , TiMF
Diameter Under
Armour
mm
mm
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
9.8
0.9
10.0
1.4
14.6
647
1000
2x3x1
0.6
1.0
15.1
0.9
15.1
1.5
19.9
1034
1000
3x3x1
0.6
1.1
16.1
0.9
15.9
1.5
20.7
1188
1000
4x3x1
0.6
1.1
17.5
0.9
17.3
1.6
22.3
1339
1000
5x3x1
0.6
1.1
19.0
1.25
18.8
1.6
24.5
1628
1000
6x3x1
0.6
1.2
20.9
1.25
20.5
1.7
26.4
1867
1000
7x3x1
0.6
1.2
20.9
1.25
20.5
1.7
26.4
1921
1000
10x3x1
0.6
1.3
26.4
1.25
25.8
1.8
31.9
2563
500
12x3x1
0.6
1.3
27.3
1.25
26.7
1.8
32.8
2736
500
16x3x1
0.6
1.4
30.4
1.6
29.6
1.9
36.6
3504
500
20x3x1
0.6
1.5
34.0
1.6
33.4
2.0
40.6
4168
500
24x3x1
0.6
1.6
38.2
1.6
37.4
2.1
44.8
4892
500
30x3x1
0.6
1.6
40.4
39.6
2.1
47.8
5749
500
Instrument Cables
268
1x3x1.5
0.6
0.9
10.5
0.9
10.7
1.4
15.3
707
1000
2x3x1.5
0.6
1.1
16.5
0.9
16.3
1.6
21.3
1212
1000
3x3x1.5
0.6
1.1
17.4
1.25
17.2
1.6
22.9
1486
1000
4x3x1.5
0.6
1.1
19.0
1.25
18.8
1.6
24.5
1660
1000
5x3x1.5
0.6
1.2
20.9
1.25
20.5
1.7
26.4
1923
1000
6x3x1.5
0.6
1.2
22.7
1.25
22.3
1.7
28.2
2135
1000
7x3x1.5
0.6
1.2
22.7
1.25
22.3
1.7
28.2
2207
1000
10x3x1.5
0.6
1.4
29.1
1.25
28.3
1.8
34.4
3046
500
12x3x1.5
0.6
1.4
30.0
1.25
29.2
1.9
35.5
3278
500
16x3x1.5
0.6
1.5
33.5
1.6
32.9
2.0
40.1
4235
500
20x3x1.5
0.6
1.6
37.9
1.6
37.1
2.1
44.5
5048
500
24x3x1.5
0.6
1.7
42.1
41.1
2.2
49.5
6226
500
30x3x1.5
0.6
1.7
44.5
43.5
2.2
51.9
6903
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-Y(St)YKYRY , TiMF
mm
mm
mm
mm
Kg/Km
meter
Diameter Under
Armour
mm
Standard
Packing Length
Armour Wire
Diameter
mm
Weight
Diameter Over
Lead Sheath
mm
Overall
Diameter
Lead Sheath
Thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
Insulation
thickness
EN 50288-7 (500 V)
0.7
1.0
12.0
0.9
12.0
1.5
16.8
868
1000
2x3x2.5
0.7
1.1
19.0
1.25
18.8
1.6
24.5
1602
1000
3x3x2.5
0.7
1.2
20.4
1.25
20.0
1.7
25.9
1868
1000
4x3x2.5
0.7
1.2
22.2
1.25
21.8
1.7
27.7
2121
1000
5x3x2.5
0.7
1.3
24.5
1.25
23.9
1.8
30.0
2459
500
6x3x2.5
0.7
1.3
26.7
1.25
26.1
1.8
32.2
2734
500
7x3x2.5
0.7
1.3
26.7
1.25
26.1
1.8
32.2
2842
500
10x3x2.5
0.7
1.5
34.3
1.6
33.7
2.0
40.9
4265
500
12x3x2.5
0.7
1.5
35.9
1.6
35.3
2.0
42.5
4654
500
16x3x2.5
0.7
1.6
40.0
39.2
2.2
47.6
5948
500
20x3x2.5
0.7
1.8
45.0
44.2
2.3
52.8
7196
500
24x3x2.5
0.7
1.9
50.4
2.5
49.4
2.4
59.2
8943
500
30x3x2.5
0.7
2.0
53.6
2.5
52.4
2.5
62.4
10168
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
269
KCI
RE-Y(St)YKYRY
Fire Resistant
EN 50288-7 (500 V)
RE-Y(St)YKYRY Multi-Core
RE-Y(St)YKYRY Multi-Pair
RE-Y(St)YKYRY Multi-Triple
RE-Y(St)YKYRY PiMF
RE-Y(St)YKYRY TiMF
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
RE-2X(St)HKHRH
Fire Resistant
Multi-Core
Multi-Pair
Multi-Triple
PiMF
TiMF
KCI
RE-2X(St)YKYRY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
272
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
9.2
0.9
9.4
1.4
14.0
564
1000
3x0.5
0.6
0.9
9.7
0.9
9.9
1.4
14.5
594
1000
4x0.5
0.6
0.9
10.3
0.9
10.5
1.4
15.1
638
1000
5x0.5
0.6
0.9
11.1
0.9
11.3
1.4
15.9
689
1000
6x0.5
0.6
0.9
11.8
0.9
12.0
1.4
16.6
736
1000
7x0.5
0.6
0.9
11.8
0.9
12.0
1.4
16.6
746
1000
8x0.5
0.6
1.0
13.6
0.9
13.6
1.5
18.4
883
1000
10x0.5
0.6
1.0
14.6
0.9
14.6
1.5
19.4
962
1000
12x0.5
0.6
1.0
15.0
0.9
15.0
1.5
19.8
1003
1000
16x0.5
0.6
1.0
16.4
0.9
16.4
1.5
21.2
1120
1000
20x0.5
0.6
1.1
18.2
0.9
18.0
1.6
23.0
1306
1000
24x0.5
0.6
1.1
20.0
1.25
19.8
1.6
25.5
1602
1000
30x0.5
0.6
1.1
21.0
1.25
20.8
1.6
26.5
1723
1000
2x0.75
0.6
0.9
9.7
0.9
9.9
1.4
14.5
594
1000
3x0.75
0.6
0.9
10.1
0.9
10.3
1.4
14.9
634
1000
4x0.75
0.6
0.9
10.8
0.9
11.0
1.4
15.6
683
1000
5x0.75
0.6
0.9
11.6
0.9
11.8
1.4
16.4
740
1000
6x0.75
0.6
1.0
12.7
0.9
12.7
1.5
17.5
837
1000
7x0.75
0.6
1.0
12.7
0.9
12.7
1.5
17.5
849
1000
8x0.75
0.6
1.0
14.3
0.9
14.3
1.5
19.1
959
1000
10x0.75
0.6
1.0
15.4
0.9
15.4
1.5
20.2
1049
1000
12x0.75
0.6
1.0
15.9
0.9
15.9
1.5
20.7
1096
1000
16x0.75
0.6
1.1
17.6
0.9
17.4
1.6
22.4
1290
1000
20x0.75
0.6
1.1
19.4
1.25
19.2
1.6
24.9
1590
1000
24x0.75
0.6
1.1
21.2
1.25
21.0
1.6
26.7
1770
1000
30x0.75
0.6
1.2
22.6
1.25
22.2
1.7
28.1
1986
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
273
KCI
RE-2X(St)YKYRY
mm
mm
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
10.0
0.9
10.2
1.4
14.8
616
1000
3x1
0.6
0.9
10.5
0.9
10.7
1.4
15.3
659
1000
4x1
0.6
0.9
11.3
0.9
11.5
1.4
16.1
717
1000
5x1
0.6
1.0
12.3
0.9
12.3
1.4
16.9
809
1000
6x1
0.6
1.0
13.2
0.9
13.2
1.5
18.0
881
1000
7x1
0.6
1.0
13.2
0.9
13.2
1.5
18.0
897
1000
8x1
0.6
1.0
15.0
0.9
15.0
1.5
19.8
1013
1000
10x1
0.6
1.0
16.2
0.9
16.2
1.5
21.0
1111
1000
12x1
0.6
1.0
16.6
0.9
16.6
1.5
21.4
1170
1000
16x1
0.6
1.1
18.4
0.9
18.2
1.6
23.2
1380
1000
20x1
0.6
1.1
20.3
1.25
20.1
1.6
25.8
1700
1000
24x1
0.6
1.2
22.5
1.25
22.1
1.7
28.0
1968
1000
30x1
0.6
1.2
23.7
1.25
23.3
1.7
29.2
2144
500
Instrument Cables
274
2x1.5
0.6
0.9
10.6
0.9
10.8
1.4
15.4
666
1000
3x1.5
0.6
0.9
11.2
0.9
11.4
1.4
16.0
717
1000
4x1.5
0.6
1.0
12.2
0.9
12.2
1.4
16.8
821
1000
5x1.5
0.6
1.0
13.1
0.9
13.1
1.5
17.9
901
1000
6x1.5
0.6
1.0
14.1
0.9
14.1
1.5
18.9
977
1000
7x1.5
0.6
1.0
14.1
0.9
14.1
1.5
18.9
998
1000
8x1.5
0.6
1.0
16.1
0.9
16.1
1.5
20.9
1134
1000
10x1.5
0.6
1.1
17.6
0.9
17.4
1.6
22.4
1309
1000
12x1.5
0.6
1.1
18.1
0.9
17.9
1.6
22.9
1383
1000
16x1.5
0.6
1.1
19.9
1.25
19.7
1.6
25.4
1719
1000
20x1.5
0.6
1.2
22.1
1.25
21.7
1.7
27.6
2015
1000
24x1.5
0.6
1.2
24.3
1.25
23.9
1.7
29.8
2250
500
30x1.5
0.6
1.3
25.8
1.25
25.2
1.7
31.1
2550
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
12.1
0.9
12.1
1.4
16.7
805
1000
3x2.5
0.7
1.0
12.7
0.9
12.7
1.5
17.5
880
1000
4x2.5
0.7
1.0
13.7
0.9
13.7
1.5
18.5
969
1000
5x2.5
0.7
1.0
14.8
0.9
14.8
1.5
19.6
1062
1000
6x2.5
0.7
1.1
16.2
0.9
16.0
1.5
20.8
1210
1000
7x2.5
0.7
1.1
16.2
0.9
16.0
1.5
20.8
1242
1000
8x2.5
0.7
1.1
18.5
1.25
18.3
1.6
24.0
1568
1000
10x2.5
0.7
1.1
20.0
1.25
19.8
1.6
25.5
1741
1000
12x2.5
0.7
1.2
20.9
1.25
20.5
1.7
26.4
1913
1000
16x2.5
0.7
1.2
23.0
1.25
22.6
1.7
28.5
2190
1000
20x2.5
0.7
1.3
25.6
1.25
25.0
1.8
31.1
2580
500
24x2.5
0.7
1.3
28.2
1.25
27.6
1.8
33.7
2899
500
30x2.5
0.7
1.4
30.0
1.25
29.2
1.8
35.3
3296
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
275
KCI
RE-2X(St)YKYRY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
276
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
9.2
0.9
9.4
1.4
14.0
565
1000
2x2x0.5
0.6
1.0
12.8
0.9
12.8
1.4
17.4
796
1000
3x2x0.5
0.6
1.0
13.4
0.9
13.4
1.5
18.2
859
1000
4x2x0.5
0.6
1.0
14.5
0.9
14.5
1.5
19.3
942
1000
5x2x0.5
0.6
1.0
15.7
0.9
15.7
1.5
20.5
1023
1000
6x2x0.5
0.6
1.1
17.2
0.9
17.0
1.5
21.8
1165
1000
7x2x0.5
0.6
1.1
17.2
0.9
17.0
1.5
21.8
1184
1000
10x2x0.5
0.6
1.1
21.4
1.25
21.2
1.6
26.9
1659
1000
12x2x0.5
0.6
1.2
22.3
1.25
21.9
1.7
27.8
1817
1000
16x2x0.5
0.6
1.2
24.6
1.25
24.2
1.7
30.1
2046
500
20x2x0.5
0.6
1.3
27.4
1.25
26.8
1.8
32.9
2388
500
24x2x0.5
0.6
1.3
30.3
1.6
29.7
1.8
36.5
2899
500
30x2x0.5
0.6
1.4
32.2
1.6
31.4
1.9
38.4
3246
500
1x2x0.75
0.6
0.9
9.7
0.9
9.9
1.4
14.5
595
1000
2x2x0.75
0.6
1.0
13.4
0.9
13.4
1.5
18.2
860
1000
3x2x0.75
0.6
1.0
14.2
0.9
14.2
1.5
19.0
924
1000
4x2x0.75
0.6
1.0
15.4
0.9
15.4
1.5
20.2
1017
1000
5x2x0.75
0.6
1.1
16.8
0.9
16.6
1.5
21.4
1162
1000
6x2x0.75
0.6
1.1
18.2
0.9
18.0
1.6
23.0
1280
1000
7x2x0.75
0.6
1.1
18.2
0.9
18.0
1.6
23.0
1305
1000
10x2x0.75
0.6
1.2
23.0
1.25
22.6
1.7
28.5
1897
1000
12x2x0.75
0.6
1.2
23.7
1.25
23.3
1.7
29.2
2000
500
16x2x0.75
0.6
1.3
26.4
1.25
25.8
1.7
31.7
2346
500
20x2x0.75
0.6
1.3
29.3
1.25
28.7
1.8
34.8
2669
500
24x2x0.75
0.6
1.4
32.5
1.6
31.7
1.9
38.7
3321
500
30x2x0.75
0.6
1.4
34.4
1.6
33.6
1.9
40.6
3634
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
277
KCI
RE-2X(St)YKYRY
mm
mm
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
10.0
0.9
10.2
1.4
14.8
616
1000
2x2x1
0.6
1.0
14.0
0.9
14.0
1.5
18.8
900
1000
3x2x1
0.6
1.0
14.8
0.9
14.8
1.5
19.6
972
1000
4x2x1
0.6
1.0
16.1
0.9
16.1
1.5
20.9
1079
1000
5x2x1
0.6
1.1
17.6
0.9
17.4
1.5
22.2
1233
1000
6x2x1
0.6
1.1
19.1
1.25
18.9
1.6
24.6
1511
1000
7x2x1
0.6
1.1
19.1
1.25
18.9
1.6
24.6
1542
1000
10x2x1
0.6
1.2
24.2
1.25
23.8
1.7
29.7
2028
500
12x2x1
0.6
1.2
25.0
1.25
24.6
1.7
30.5
2145
500
16x2x1
0.6
1.3
27.8
1.25
27.2
1.8
33.3
2536
500
20x2x1
0.6
1.3
30.8
1.6
30.2
1.8
37.0
3113
500
24x2x1
0.6
1.4
34.3
1.6
33.5
1.9
40.5
3599
500
30x2x1
0.6
1.5
36.5
1.6
35.9
2.0
43.1
4103
500
Instrument Cables
278
1x2x1.5
0.6
0.9
10.6
0.9
10.8
1.4
15.4
667
1000
2x2x1.5
0.6
1.0
15.0
0.9
15.0
1.5
19.8
989
1000
3x2x1.5
0.6
1.0
15.9
0.9
15.9
1.5
20.7
1082
1000
4x2x1.5
0.6
1.1
17.5
0.9
17.3
1.6
22.3
1266
1000
5x2x1.5
0.6
1.1
19.0
1.25
18.8
1.6
24.5
1539
1000
6x2x1.5
0.6
1.1
20.6
1.25
20.4
1.6
26.1
1692
1000
7x2x1.5
0.6
1.1
20.6
1.25
20.4
1.6
26.1
1734
1000
10x2x1.5
0.6
1.3
26.3
1.25
25.7
1.8
31.8
2396
500
12x2x1.5
0.6
1.3
27.2
1.25
26.6
1.8
32.7
2543
500
16x2x1.5
0.6
1.3
30.1
1.6
29.5
1.9
36.5
3153
500
20x2x1.5
0.6
1.4
33.7
1.6
32.9
1.9
39.9
3699
500
24x2x1.5
0.6
1.5
37.5
1.6
36.9
2.0
44.1
4330
500
30x2x1.5
0.6
1.6
40.3
39.5
2.1
47.7
5302
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
12.1
0.9
12.1
1.4
16.7
806
1000
2x2x2.5
0.7
1.1
17.2
0.9
17.0
1.6
22.0
1227
1000
3x2x2.5
0.7
1.1
18.3
1.25
18.1
1.6
23.8
1499
1000
4x2x2.5
0.7
1.1
19.9
1.25
19.7
1.6
25.4
1678
1000
5x2x2.5
0.7
1.2
21.9
1.25
21.5
1.7
27.4
1936
1000
6x2x2.5
0.7
1.2
23.8
1.25
23.4
1.7
29.3
2132
500
7x2x2.5
0.7
1.2
23.8
1.25
23.4
1.7
29.3
2197
500
10x2x2.5
0.7
1.4
30.6
1.6
29.8
1.9
36.8
3277
500
12x2x2.5
0.7
1.4
31.6
1.6
30.8
1.9
37.8
3494
500
16x2x2.5
0.7
1.5
35.3
1.6
34.7
2.0
41.9
4205
500
20x2x2.5
0.7
1.6
39.9
39.1
2.1
47.3
5358
500
24x2x2.5
0.7
1.7
44.4
43.4
2.2
51.8
6180
500
30x2x2.5
0.7
1.8
47.2
46.4
2.3
55.0
7040
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
279
KCI
RE-2X(St)YKYRY
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
Mica-glass Tape + XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Inner Covering
Extruded PVC
Metal Sheath
Lead Sheath (Cover)
Inner Covering
Extruded PVC
(Bedding)
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
IEC 60331
Instrument Cables
Criteria
Conductor cross section
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
280
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
9.7
0.9
9.9
1.4
14.5
594
1000
2x3x0.5
0.6
1.0
13.9
0.9
13.9
1.5
18.7
889
1000
3x3x0.5
0.6
1.0
14.7
0.9
14.7
1.5
19.5
958
1000
4x3x0.5
0.6
1.0
16.0
0.9
16.0
1.5
20.8
1057
1000
5x3x0.5
0.6
1.1
17.5
0.9
17.3
1.5
22.1
1213
1000
6x3x0.5
0.6
1.1
18.9
1.25
18.7
1.6
24.4
1476
1000
7x3x0.5
0.6
1.1
18.9
1.25
18.7
1.6
24.4
1505
1000
10x3x0.5
0.6
1.2
24.0
1.25
23.6
1.7
29.5
1990
500
12x3x0.5
0.6
1.2
24.7
1.25
24.3
1.7
30.2
2092
500
16x3x0.5
0.6
1.3
27.5
1.25
26.9
1.8
33.0
2480
500
20x3x0.5
0.6
1.3
30.6
1.6
30.0
1.8
36.8
3029
500
24x3x0.5
0.6
1.4
34.0
1.6
33.2
1.9
40.2
3502
500
30x3x0.5
0.6
1.5
36.2
1.6
35.6
2.0
42.8
4005
500
1x3x0.75
0.6
0.9
10.1
0.9
10.3
1.4
14.9
634
1000
2x3x0.75
0.6
1.0
14.7
0.9
14.7
1.5
19.5
956
1000
3x3x0.75
0.6
1.0
15.5
0.9
15.5
1.5
20.3
1043
1000
4x3x0.75
0.6
1.1
17.1
0.9
16.9
1.5
21.7
1203
1000
5x3x0.75
0.6
1.1
18.6
0.9
18.4
1.6
23.4
1338
1000
6x3x0.75
0.6
1.1
20.1
1.25
19.9
1.6
25.6
1623
1000
7x3x0.75
0.6
1.1
20.1
1.25
19.9
1.6
25.6
1661
1000
10x3x0.75
0.6
1.2
25.5
1.25
25.1
1.7
31.0
2199
500
12x3x0.75
0.6
1.3
26.6
1.25
26.0
1.7
31.9
2405
500
16x3x0.75
0.6
1.3
29.4
1.25
28.8
1.8
34.9
2776
500
20x3x0.75
0.6
1.4
32.9
1.6
32.1
1.9
39.1
3505
500
24x3x0.75
0.6
1.5
36.6
1.6
36.0
2.0
43.2
4103
500
30x3x0.75
0.6
1.5
39.1
38.5
2.1
46.7
4935
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
281
KCI
RE-2X(St)YKYRY
mm
mm
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
10.5
0.9
10.7
1.4
15.3
660
1000
2x3x1
0.6
1.0
15.4
0.9
15.4
1.5
20.2
1005
1000
3x3x1
0.6
1.0
16.3
0.9
16.3
1.5
21.1
1102
1000
4x3x1
0.6
1.1
17.9
0.9
17.7
1.6
22.7
1290
1000
5x3x1
0.6
1.1
19.5
1.25
19.3
1.6
25.0
1573
1000
6x3x1
0.6
1.1
21.1
1.25
20.9
1.6
26.6
1730
1000
7x3x1
0.6
1.1
21.1
1.25
20.9
1.6
26.6
1777
1000
10x3x1
0.6
1.3
27.1
1.25
26.5
1.8
32.6
2451
500
12x3x1
0.6
1.3
28.0
1.25
27.4
1.8
33.5
2617
500
16x3x1
0.6
1.3
31.0
1.6
30.4
1.9
37.4
3257
500
20x3x1
0.6
1.4
34.7
1.6
33.9
1.9
40.9
3804
500
24x3x1
0.6
1.5
38.6
38.0
2.0
46.0
4795
500
30x3x1
0.6
1.6
41.5
40.7
2.1
48.9
5485
500
Instrument Cables
282
1x3x1.5
0.6
0.9
11.2
0.9
11.4
1.4
16.0
718
1000
2x3x1.5
0.6
1.1
16.7
0.9
16.5
1.5
21.3
1166
1000
3x3x1.5
0.6
1.1
17.7
0.9
17.5
1.6
22.5
1296
1000
4x3x1.5
0.6
1.1
19.3
1.25
19.1
1.6
24.8
1605
1000
5x3x1.5
0.6
1.2
21.2
1.25
20.8
1.6
26.5
1843
1000
6x3x1.5
0.6
1.2
23.0
1.25
22.6
1.7
28.5
2042
1000
7x3x1.5
0.6
1.2
23.0
1.25
22.6
1.7
28.5
2106
1000
10x3x1.5
0.6
1.3
29.3
1.25
28.7
1.8
34.8
2826
500
12x3x1.5
0.6
1.4
30.5
1.6
29.7
1.9
36.7
3350
500
16x3x1.5
0.6
1.4
33.8
1.6
33.0
1.9
40.0
3877
500
20x3x1.5
0.6
1.5
38.3
37.7
2.1
45.9
5010
500
24x3x1.5
0.6
1.6
42.5
41.7
2.1
49.9
5797
500
30x3x1.5
0.6
1.7
45.3
44.3
2.2
52.7
6552
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
12.7
0.9
12.7
1.5
17.5
882
1000
2x3x2.5
0.7
1.1
19.0
1.25
18.8
1.6
24.5
1542
1000
3x3x2.5
0.7
1.1
20.2
1.25
20.0
1.6
25.7
1721
1000
4x3x2.5
0.7
1.2
22.3
1.25
21.9
1.7
27.8
2028
1000
5x3x2.5
0.7
1.2
24.3
1.25
23.9
1.7
29.8
2262
500
6x3x2.5
0.7
1.3
26.7
1.25
26.1
1.8
32.2
2613
500
7x3x2.5
0.7
1.3
26.7
1.25
26.1
1.8
32.2
2709
500
10x3x2.5
0.7
1.5
34.4
1.6
33.8
2.0
41.0
4055
500
12x3x2.5
0.7
1.5
35.5
1.6
34.9
2.0
42.1
4348
500
16x3x2.5
0.7
1.6
40.0
39.2
2.1
47.4
5625
500
20x3x2.5
0.7
1.7
44.8
43.8
2.2
52.2
6623
500
24x3x2.5
0.7
1.8
49.9
2.5
49.1
2.4
58.9
8278
500
30x3x2.5
0.7
1.9
53.5
2.5
52.5
2.4
62.3
9446
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
283
KCI
RE-2X(St)YKYRY , PiMF
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Conductor cross section
Black,Blue (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
284
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
Armour Wire
Diameter
Diameter Under
Armour
mm
mm
mm
Standard
Packing Length
Diameter Over
Lead Sheath
mm
Weight
Lead Sheath
Thickness
mm
Overall
Diameter
Insulation
thickness
mm2
Sheath thickness
Nominal cross
section area of
conductor
mm
mm
Kg/Km
meter
KCI
RE-2X(St)YKYRY , PiMF
0.6
0.9
9.6
0.9
9.8
1.4
14.4
593
1000
2x2x0.5
0.6
1.0
14.1
0.9
14.1
1.5
18.9
898
1000
3x2x0.5
0.6
1.0
14.9
0.9
14.9
1.5
19.7
972
1000
4x2x0.5
0.6
1.0
16.2
0.9
16.2
1.5
21.0
1071
1000
5x2x0.5
0.6
1.1
17.7
0.9
17.5
1.5
22.3
1223
1000
6x2x0.5
0.6
1.1
19.2
1.25
19.0
1.6
24.7
1498
1000
7x2x0.5
0.6
1.1
19.2
1.25
19.0
1.6
24.7
1526
1000
10x2x0.5
0.6
1.2
24.3
1.25
23.9
1.7
29.8
2005
500
12x2x0.5
0.6
1.2
25.1
1.25
24.7
1.7
30.6
2116
500
16x2x0.5
0.6
1.3
28.0
1.25
27.4
1.8
33.5
2506
500
20x2x0.5
0.6
1.4
31.2
1.6
30.4
1.9
37.4
3161
500
24x2x0.5
0.6
1.4
34.5
1.6
33.7
1.9
40.7
3539
500
30x2x0.5
0.6
1.5
36.7
1.6
36.1
2.0
43.3
4043
500
1x2x0.75
0.6
0.9
10.0
0.9
10.2
1.4
14.8
624
1000
2x2x0.75
0.6
1.0
14.8
0.9
14.8
1.5
19.6
963
1000
3x2x0.75
0.6
1.0
15.7
0.9
15.7
1.5
20.5
1041
1000
4x2x0.75
0.6
1.1
17.3
0.9
17.1
1.5
21.9
1205
1000
5x2x0.75
0.6
1.1
18.7
1.25
18.5
1.6
24.2
1483
1000
6x2x0.75
0.6
1.1
20.3
1.25
20.1
1.6
25.8
1615
1000
7x2x0.75
0.6
1.1
20.3
1.25
20.1
1.6
25.8
1650
1000
10x2x0.75
0.6
1.3
26.0
1.25
25.4
1.7
31.3
2265
500
12x2x0.75
0.6
1.3
26.9
1.25
26.3
1.8
32.4
2407
500
16x2x0.75
0.6
1.3
29.7
1.25
29.1
1.8
35.2
2754
500
20x2x0.75
0.6
1.4
33.2
1.6
32.4
1.9
39.4
3481
500
24x2x0.75
0.6
1.5
37.0
1.6
36.4
2.0
43.6
4071
500
30x2x0.75
0.6
1.5
39.5
38.9
2.1
47.1
4869
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
285
KCI
RE-2X(St)YKYRY , PiMF
mm
mm
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
10.4
0.9
10.6
1.4
15.2
651
1000
2x2x1
0.6
1.0
15.5
0.9
15.5
1.5
20.3
1005
1000
3x2x1
0.6
1.0
16.4
0.9
16.4
1.5
21.2
1097
1000
4x2x1
0.6
1.1
18.0
0.9
17.8
1.6
22.8
1275
1000
5x2x1
0.6
1.1
19.6
1.25
19.4
1.6
25.1
1563
1000
6x2x1
0.6
1.1
21.3
1.25
21.1
1.6
26.8
1715
1000
7x2x1
0.6
1.1
21.3
1.25
21.1
1.6
26.8
1755
1000
10x2x1
0.6
1.3
27.3
1.25
26.7
1.8
32.8
2418
500
12x2x1
0.6
1.3
28.2
1.25
27.6
1.8
33.7
2562
500
16x2x1
0.6
1.4
31.4
1.6
30.6
1.9
37.6
3265
500
20x2x1
0.6
1.4
34.9
1.6
34.1
1.9
41.1
3723
500
24x2x1
0.6
1.5
39.3
38.7
2.1
46.9
4774
500
30x2x1
0.6
1.6
41.8
41.0
2.1
49.2
5335
500
Instrument Cables
286
1x2x1.5
0.6
0.9
11.0
0.9
11.2
1.4
15.8
702
1000
2x2x1.5
0.6
1.1
16.8
0.9
16.6
1.5
21.4
1148
1000
3x2x1.5
0.6
1.1
17.7
0.9
17.5
1.6
22.5
1267
1000
4x2x1.5
0.6
1.1
19.3
1.25
19.1
1.6
24.8
1565
1000
5x2x1.5
0.6
1.2
21.3
1.25
20.9
1.6
26.6
1793
1000
6x2x1.5
0.6
1.2
23.1
1.25
22.7
1.7
28.6
1981
1000
7x2x1.5
0.6
1.2
23.1
1.25
22.7
1.7
28.6
2034
1000
10x2x1.5
0.6
1.3
29.4
1.25
28.8
1.8
34.9
2723
500
12x2x1.5
0.6
1.4
30.6
1.6
29.8
1.9
36.8
3225
500
16x2x1.5
0.6
1.4
33.9
1.6
33.1
1.9
40.1
3708
500
20x2x1.5
0.6
1.5
38.4
37.8
2.1
46.0
4824
500
24x2x1.5
0.6
1.6
42.7
41.9
2.1
50.1
5543
500
30x2x1.5
0.6
1.7
45.4
44.4
2.2
52.8
6232
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY , PiMF
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
12.4
0.9
12.4
1.5
17.2
845
1000
2x2x2.5
0.7
1.1
19.0
1.25
18.8
1.6
24.5
1499
1000
3x2x2.5
0.7
1.1
20.1
1.25
19.9
1.6
25.6
1656
1000
4x2x2.5
0.7
1.2
22.2
1.25
21.8
1.7
27.7
1931
1000
5x2x2.5
0.7
1.2
24.2
1.25
23.8
1.7
29.7
2154
500
6x2x2.5
0.7
1.3
26.6
1.25
26.0
1.8
32.1
2472
500
7x2x2.5
0.7
1.3
26.6
1.25
26.0
1.8
32.1
2548
500
10x2x2.5
0.7
1.5
34.2
1.6
33.6
2.0
40.8
3838
500
12x2x2.5
0.7
1.5
35.4
1.6
34.8
2.0
42.0
4089
500
16x2x2.5
0.7
1.6
39.9
39.1
2.1
47.3
5280
500
20x2x2.5
0.7
1.7
44.7
43.7
2.2
52.1
6165
500
24x2x2.5
0.7
1.8
49.7
2.5
48.9
2.4
58.7
7761
500
30x2x2.5
0.7
1.9
53.3
2.5
52.3
2.4
62.1
8799
500
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
287
KCI
RE-2X(St)YKYRY , TiMF
EN 50288-7 (500 V)
Fire Resistant
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Inner Covering
Metal Sheath
Inner Covering
(Bedding)
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
IEC 60331
Criteria
Blue,White,Red (Numbered)
10x O.D
Screened
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
288
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY , TiMF
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.6
0.9
10.0
0.9
10.2
1.4
14.8
623
1000
2x3x0.5
0.6
1.0
15.4
0.9
15.4
1.5
20.2
995
1000
3x3x0.5
0.6
1.0
16.3
0.9
16.3
1.5
21.1
1078
1000
4x3x0.5
0.6
1.1
18.0
0.9
17.8
1.6
22.8
1258
1000
5x3x0.5
0.6
1.1
19.5
1.25
19.3
1.6
25.0
1543
1000
6x3x0.5
0.6
1.1
21.2
1.25
21.0
1.6
26.7
1691
1000
7x3x0.5
0.6
1.1
21.2
1.25
21.0
1.6
26.7
1729
1000
10x3x0.5
0.6
1.3
27.2
1.25
26.6
1.8
32.7
2379
500
12x3x0.5
0.6
1.3
28.1
1.25
27.5
1.8
33.6
2518
500
16x3x0.5
0.6
1.4
31.3
1.6
30.5
1.9
37.5
3208
500
20x3x0.5
0.6
1.4
34.8
1.6
34.0
1.9
41.0
3653
500
24x3x0.5
0.6
1.5
39.1
38.5
2.0
46.5
4672
500
30x3x0.5
0.6
1.6
41.6
40.8
2.1
49.0
5233
500
1x3x0.75
0.6
0.9
10.5
0.9
10.7
1.4
15.3
664
1000
2x3x0.75
0.6
1.0
16.3
0.9
16.3
1.5
21.1
1066
1000
3x3x0.75
0.6
1.1
17.4
0.9
17.2
1.5
22.0
1217
1000
4x3x0.75
0.6
1.1
19.0
1.25
18.8
1.6
24.5
1511
1000
5x3x0.75
0.6
1.1
20.7
1.25
20.5
1.6
26.2
1670
1000
6x3x0.75
0.6
1.2
22.7
1.25
22.3
1.7
28.2
1919
1000
7x3x0.75
0.6
1.2
22.7
1.25
22.3
1.7
28.2
1967
1000
10x3x0.75
0.6
1.3
28.9
1.25
28.3
1.8
34.4
2616
500
12x3x0.75
0.6
1.3
29.8
1.25
29.2
1.8
35.3
2778
500
16x3x0.75
0.6
1.4
33.3
1.6
32.5
1.9
39.5
3552
500
20x3x0.75
0.6
1.5
37.3
1.6
36.7
2.0
43.9
4224
500
24x3x0.75
0.6
1.6
41.9
41.1
2.1
49.3
5311
500
30x3x0.75
0.6
1.7
44.5
43.5
2.2
51.9
5958
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
289
KCI
RE-2X(St)YKYRY , TiMF
mm
mm
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
mm
mm
Kg/Km
meter
0.6
0.9
10.9
0.9
11.1
1.4
15.7
689
1000
2x3x1
0.6
1.1
17.2
0.9
17.0
1.5
21.8
1171
1000
3x3x1
0.6
1.1
18.2
0.9
18.0
1.6
23.0
1295
1000
4x3x1
0.6
1.1
19.9
1.25
19.7
1.6
25.4
1597
1000
5x3x1
0.6
1.2
21.9
1.25
21.5
1.7
27.4
1850
1000
6x3x1
0.6
1.2
23.8
1.25
23.4
1.7
29.3
2033
500
7x3x1
0.6
1.2
23.8
1.25
23.4
1.7
29.3
2090
500
10x3x1
0.6
1.3
30.3
1.6
29.7
1.8
36.5
3022
500
12x3x1
0.6
1.4
31.6
1.6
30.8
1.9
37.8
3317
500
16x3x1
0.6
1.4
35.0
1.6
34.2
1.9
41.2
3817
500
20x3x1
0.6
1.5
39.6
39.0
2.1
47.2
4946
500
24x3x1
0.6
1.6
44.1
43.3
2.2
51.7
5728
500
30x3x1
0.6
1.7
46.9
45.9
2.2
54.3
6449
500
Instrument Cables
290
1x3x1.5
0.6
0.9
11.5
0.9
11.7
1.4
16.3
748
1000
2x3x1.5
0.6
1.1
18.4
1.25
18.2
1.6
23.9
1444
1000
3x3x1.5
0.6
1.1
19.5
1.25
19.3
1.6
25.0
1597
1000
4x3x1.5
0.6
1.2
21.6
1.25
21.2
1.7
27.1
1862
1000
5x3x1.5
0.6
1.2
23.5
1.25
23.1
1.7
29.0
2067
500
6x3x1.5
0.6
1.3
25.8
1.25
25.2
1.7
31.1
2361
500
7x3x1.5
0.6
1.3
25.8
1.25
25.2
1.7
31.1
2435
500
10x3x1.5
0.6
1.4
33.0
1.6
32.2
1.9
39.2
3526
500
12x3x1.5
0.6
1.4
34.1
1.6
33.3
1.9
40.3
3766
500
16x3x1.5
0.6
1.5
38.4
37.8
2.1
46.0
4965
500
20x3x1.5
0.6
1.6
43.0
42.2
2.2
50.6
5807
500
24x3x1.5
0.6
1.7
47.9
2.5
46.9
2.3
56.5
7213
500
30x3x1.5
0.6
1.8
51.0
2.5
50.2
2.4
60.0
8214
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)YKYRY , TiMF
mm
mm
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
Diameter Under
Armour
mm
Weight
Armour Wire
Diameter
mm
Overall
Diameter
Diameter Over
Lead Sheath
mm2
Sheath thickness
Nominal cross
section area of
conductor
Lead Sheath
Thickness
EN 50288-7 (500 V)
Insulation
thickness
Fire Resistant
0.7
1.0
13.1
0.9
13.1
1.5
17.9
914
1000
2x3x2.5
0.7
1.2
21.1
1.25
20.7
1.7
26.6
1775
1000
3x3x2.5
0.7
1.2
22.5
1.25
22.1
1.7
28.0
1976
1000
4x3x2.5
0.7
1.2
24.6
1.25
24.2
1.7
30.1
2237
500
5x3x2.5
0.7
1.3
27.1
1.25
26.5
1.8
32.6
2596
500
6x3x2.5
0.7
1.4
29.8
1.25
29.0
1.8
35.1
2976
500
7x3x2.5
0.7
1.4
29.8
1.25
29.0
1.8
35.1
3084
500
10x3x2.5
0.7
1.6
38.8
38.0
2.1
46.2
5035
500
12x3x2.5
0.7
1.6
40.1
39.3
2.1
47.5
5384
500
16x3x2.5
0.7
1.7
44.8
43.8
2.2
52.2
6394
500
20x3x2.5
0.7
1.8
50.5
2.5
49.7
2.4
59.5
8251
500
24x3x2.5
0.7
2.0
56.5
2.5
55.3
2.5
65.3
9655
250
30x3x2.5
0.7
2.0
59.8
3.15
58.6
2.6
70.1
11578
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
291
KCI
RE-2X(St)(L)2Y4YRY
EN 50288-7 (500 V)
RE-2X(St)(L)2Y4YRY Multi-Pair
RE-2X(St)(L)2Y4YRY Multi-Triple
RE-2X(St)(L)2Y4YRY PiMF
RE-2X(St)(L)2Y4YRY TiMF
RE-2X(St)(L)2Y4YRH Multi-Pair
RE-2X(St)(L)2Y4YRH Multi-Triple
RE-2X(St)(L)2Y4YRH PiMF
RE-2X(St)(L)2Y4YRH TiMF
KCI
RE-2X(St)(L)2Y4YRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Collective (Overall )
Screen
Multi-Layer Sheath
Armour
Outer Sheath
+90 oC
IEC 60332-1
Instrument Cables
Criteria
Conductor cross section
Black,Blue (Numbered)
XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Sheath + Polyamide Extruded Layer
Galvanized Steel Wires
Extruded PVC
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
294
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
11.6
1.4
16.2
427
1000
2x2x0.5
0.6
0.9
14.3
1.5
19.1
547
1000
3x2x0.5
0.6
0.9
14.8
1.5
19.6
583
1000
4x2x0.5
0.6
1.25
15.7
1.5
21.2
752
1000
5x2x0.5
0.6
1.25
16.7
1.5
22.2
805
1000
6x2x0.5
0.6
1.25
17.7
1.6
23.4
879
1000
7x2x0.5
0.6
1.25
17.7
1.6
23.4
894
1000
10x2x0.5
0.6
1.25
21.2
1.6
26.9
1087
500
12x2x0.5
0.6
1.6
21.7
1.7
28.3
1321
500
16x2x0.5
0.6
1.6
23.6
1.7
30.2
1467
500
20x2x0.5
0.6
1.6
25.8
1.8
32.6
1649
500
24x2x0.5
0.6
28.1
1.8
35.7
2073
500
30x2x0.5
0.6
29.5
1.9
37.3
2258
500
1x2x0.75
0.6
0.9
12.0
1.4
16.6
446
1000
2x2x0.75
0.6
0.9
15.0
1.5
19.8
583
1000
3x2x0.75
0.6
1.25
15.6
1.5
21.1
752
1000
4x2x0.75
0.6
1.25
16.6
1.5
22.1
812
1000
5x2x0.75
0.6
1.25
17.6
1.6
23.3
892
1000
6x2x0.75
0.6
1.25
18.8
1.6
24.5
956
1000
7x2x0.75
0.6
1.25
18.8
1.6
24.5
976
1000
10x2x0.75
0.6
1.6
22.6
1.7
29.2
1400
500
12x2x0.75
0.6
1.6
23.2
1.7
29.8
1470
500
16x2x0.75
0.6
1.6
25.2
1.8
32.0
1655
500
20x2x0.75
0.6
1.6
27.6
1.8
34.4
1869
500
24x2x0.75
0.6
30.1
1.9
37.9
2348
500
30x2x0.75
0.6
31.7
1.9
39.5
2581
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
295
KCI
RE-2X(St)(L)2Y4YRY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
12.4
1.4
17.0
468
1000
2x2x1
0.6
1.25
15.6
1.5
21.1
741
1000
3x2x1
0.6
1.25
16.2
1.5
21.7
790
1000
4x2x1
0.6
1.25
17.3
1.5
22.8
867
1000
5x2x1
0.6
1.25
18.4
1.6
24.1
944
1000
6x2x1
0.6
1.25
19.7
1.6
25.4
1025
500
7x2x1
0.6
1.25
19.7
1.6
25.4
1051
500
10x2x1
0.6
1.6
23.7
1.7
30.3
1510
500
12x2x1
0.6
1.6
24.4
1.7
31.0
1592
500
16x2x1
0.6
1.6
26.6
1.8
33.4
1820
500
20x2x1
0.6
29.2
1.9
37.0
2328
500
24x2x1
0.6
31.9
1.9
39.7
2593
500
30x2x1
0.6
33.6
2.0
41.6
2853
500
Instrument Cables
296
1x2x1.5
0.6
0.9
13.0
1.4
17.6
502
1000
2x2x1.5
0.6
1.25
16.6
1.5
22.1
804
1000
3x2x1.5
0.6
1.25
17.3
1.6
23.0
885
1000
4x2x1.5
0.6
1.25
18.5
1.6
24.2
976
1000
5x2x1.5
0.6
1.25
19.8
1.6
25.5
1069
500
6x2x1.5
0.6
1.25
21.1
1.6
26.8
1164
500
7x2x1.5
0.6
1.25
21.1
1.6
26.8
1202
500
10x2x1.5
0.6
1.6
25.7
1.8
32.5
1727
500
12x2x1.5
0.6
1.6
26.4
1.8
33.2
1850
500
16x2x1.5
0.6
28.9
1.9
36.7
2402
500
20x2x1.5
0.6
31.8
1.9
39.6
2715
500
24x2x1.5
0.6
2.5
35.3
2.0
44.3
3518
500
30x2x1.5
0.6
2.5
37.1
2.1
46.3
3883
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
14.2
1.5
19.0
577
1000
2x2x2.5
0.7
1.25
18.6
1.6
24.3
948
1000
3x2x2.5
0.7
1.25
19.5
1.6
25.2
1045
500
4x2x2.5
0.7
1.25
20.9
1.6
26.6
1163
500
5x2x2.5
0.7
1.6
22.5
1.7
29.1
1473
500
6x2x2.5
0.7
1.6
24.2
1.7
30.8
1632
500
7x2x2.5
0.7
1.6
24.2
1.7
30.8
1691
500
10x2x2.5
0.7
29.8
1.9
37.6
2438
500
12x2x2.5
0.7
30.7
1.9
38.5
2600
500
16x2x2.5
0.7
34.1
2.0
42.1
3079
500
20x2x2.5
0.7
2.5
38.0
2.1
47.2
4016
500
24x2x2.5
0.7
2.5
41.8
2.2
51.2
4520
250
30x2x2.5
0.7
3.15
44.1
2.3
55.0
5685
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
297
KCI
RE-2X(St)(L)2Y4YRY
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Blue,White,Red (Numbered)
Insulation
XLPE
Cable Unit
Triple (Multi-Triple Cable)
Collective (Overall )
Polyester tape + Drain wire (Tinned copper) +
Screen
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Multi-Layer Sheath
Sheath + Polyamide Extruded Layer
Armour
Galvanized Steel Wires
Outer Sheath
Extruded PVC
+90 oC
IEC 60332-1
Instrument Cables
Criteria
Conductor cross section
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
298
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
11.9
1.4
16.5
446
1000
2x3x0.5
0.6
0.9
15.3
1.5
20.1
596
1000
3x3x0.5
0.6
1.25
15.9
1.5
21.4
762
1000
4x3x0.5
0.6
1.25
16.9
1.5
22.4
834
1000
5x3x0.5
0.6
1.25
18.0
1.6
23.7
907
1000
6x3x0.5
0.6
1.25
19.2
1.6
24.9
983
500
7x3x0.5
0.6
1.25
19.2
1.6
24.9
1005
500
10x3x0.5
0.6
1.6
23.1
1.7
29.7
1443
500
12x3x0.5
0.6
1.6
23.7
1.7
30.3
1516
500
16x3x0.5
0.6
1.6
25.8
1.8
32.6
1727
500
20x3x0.5
0.6
28.3
1.8
35.9
2194
500
24x3x0.5
0.6
30.9
1.9
38.7
2455
500
30x3x0.5
0.6
32.6
1.9
40.4
2674
500
1x3x0.75
0.6
0.9
12.4
1.4
17.0
474
1000
2x3x0.75
0.6
1.25
16.0
1.5
21.5
771
1000
3x3x0.75
0.6
1.25
16.7
1.5
22.2
825
1000
4x3x0.75
0.6
1.25
17.9
1.6
23.6
917
1000
5x3x0.75
0.6
1.25
19.1
1.6
24.8
1002
500
6x3x0.75
0.6
1.25
20.4
1.6
26.1
1089
500
7x3x0.75
0.6
1.25
20.4
1.6
26.1
1120
500
10x3x0.75
0.6
1.6
24.7
1.7
31.3
1595
500
12x3x0.75
0.6
1.6
25.4
1.8
32.2
1716
500
16x3x0.75
0.6
27.7
1.8
35.3
2205
500
20x3x0.75
0.6
30.4
1.9
38.2
2503
500
24x3x0.75
0.6
33.3
2.0
41.3
2806
500
30x3x0.75
0.6
2.5
35.5
2.0
44.5
3549
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
299
KCI
RE-2X(St)(L)2Y4YRY
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
12.8
1.4
17.4
494
1000
2x3x1
0.6
1.25
16.7
1.5
22.2
809
1000
3x3x1
0.6
1.25
17.5
1.6
23.2
892
1000
4x3x1
0.6
1.25
18.7
1.6
24.4
985
1000
5x3x1
0.6
1.25
20.0
1.6
25.7
1081
500
6x3x1
0.6
1.25
21.4
1.6
27.1
1177
500
7x3x1
0.6
1.25
21.4
1.6
27.1
1217
500
10x3x1
0.6
1.6
26.0
1.8
32.8
1766
500
12x3x1
0.6
1.6
26.8
1.8
33.6
1876
500
16x3x1
0.6
29.3
1.9
37.1
2435
500
20x3x1
0.6
32.2
1.9
40.0
2757
500
24x3x1
0.6
2.5
35.7
2.0
44.7
3568
500
30x3x1
0.6
2.5
37.6
2.1
46.8
3945
500
Instrument Cables
300
1x3x1.5
0.6
0.9
13.4
1.4
18.0
535
1000
2x3x1.5
0.6
1.25
17.8
1.6
23.5
906
1000
3x3x1.5
0.6
1.25
18.7
1.6
24.4
999
1000
4x3x1.5
0.6
1.25
20.0
1.6
25.7
1112
500
5x3x1.5
0.6
1.25
21.5
1.7
27.4
1248
500
6x3x1.5
0.6
1.6
23.0
1.7
29.6
1541
500
7x3x1.5
0.6
1.6
23.0
1.7
29.6
1597
500
10x3x1.5
0.6
28.3
1.8
35.9
2311
500
12x3x1.5
0.6
29.1
1.9
36.9
2480
500
16x3x1.5
0.6
31.9
1.9
39.7
2867
500
20x3x1.5
0.6
2.5
35.6
2.0
44.6
3750
500
24x3x1.5
0.6
2.5
39.5
2.1
48.7
4298
500
30x3x1.5
0.6
2.5
41.6
2.2
51.0
4785
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
14.8
1.5
19.6
622
1000
2x3x2.5
0.7
1.25
20.2
1.6
25.9
1079
500
3x3x2.5
0.7
1.25
21.2
1.7
27.1
1218
500
4x3x2.5
0.7
1.6
22.8
1.7
29.4
1555
500
5x3x2.5
0.7
1.6
24.6
1.8
31.4
1741
500
6x3x2.5
0.7
1.6
26.5
1.8
33.3
1935
500
7x3x2.5
0.7
1.6
26.5
1.8
33.3
2023
500
10x3x2.5
0.7
33.3
2.0
41.3
2977
500
12x3x2.5
0.7
34.3
2.0
42.3
3227
500
16x3x2.5
0.7
2.5
38.2
2.1
47.4
4253
500
20x3x2.5
0.7
2.5
42.2
2.2
51.6
4921
250
24x3x2.5
0.7
3.15
46.8
2.4
57.9
6356
250
30x3x2.5
0.7
3.15
49.4
2.4
60.5
7078
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
301
KCI
RE-2X(St)(L)2Y4YRY , PiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Multi-Layer Sheath
Armour
Outer Sheath
+90 oC
Instrument Cables
XLPE
Pair (Multi-Pair Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Sheath + Polyamide Extruded Layer
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Conductor cross section
Black,Blue (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
302
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
12.0
1.4
16.6
447
1000
2x2x0.5
0.6
0.9
15.5
1.5
20.3
607
1000
3x2x0.5
0.6
1.25
16.2
1.5
21.7
779
1000
4x2x0.5
0.6
1.25
17.2
1.6
22.9
862
1000
5x2x0.5
0.6
1.25
18.4
1.6
24.1
927
1000
6x2x0.5
0.6
1.25
19.6
1.6
25.3
1004
500
7x2x0.5
0.6
1.25
19.6
1.6
25.3
1027
500
10x2x0.5
0.6
1.6
23.6
1.7
30.2
1476
500
12x2x0.5
0.6
1.6
24.3
1.7
30.9
1552
500
16x2x0.5
0.6
1.6
26.5
1.8
33.3
1766
500
20x2x0.5
0.6
29.0
1.9
36.8
2261
500
24x2x0.5
0.6
31.7
1.9
39.5
2513
500
30x2x0.5
0.6
33.4
2.0
41.4
2753
500
1x2x0.75
0.6
0.9
12.4
1.4
17.0
472
1000
2x2x0.75
0.6
1.25
16.3
1.5
21.8
771
1000
3x2x0.75
0.6
1.25
17.0
1.5
22.5
834
1000
4x2x0.75
0.6
1.25
18.1
1.6
23.8
925
1000
5x2x0.75
0.6
1.25
19.4
1.6
25.1
1009
500
6x2x0.75
0.6
1.25
20.7
1.6
26.4
1095
500
7x2x0.75
0.6
1.25
20.7
1.6
26.4
1124
500
10x2x0.75
0.6
1.6
25.1
1.8
31.9
1614
500
12x2x0.75
0.6
1.6
25.8
1.8
32.6
1720
500
16x2x0.75
0.6
28.2
1.8
35.8
2212
500
20x2x0.75
0.6
31.0
1.9
38.8
2504
500
24x2x0.75
0.6
34.4
2.0
42.4
2862
500
30x2x0.75
0.6
2.5
36.2
2.1
45.4
3567
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
303
KCI
RE-2X(St)(L)2Y4YRY , PiMF
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
12.7
1.4
17.3
489
1000
2x2x1
0.6
1.25
16.9
1.5
22.4
814
1000
3x2x1
0.6
1.25
17.7
1.6
23.4
893
1000
4x2x1
0.6
1.25
18.9
1.6
24.6
983
500
5x2x1
0.6
1.25
20.2
1.6
25.9
1074
500
6x2x1
0.6
1.6
21.6
1.7
28.2
1350
500
7x2x1
0.6
1.6
21.6
1.7
28.2
1385
500
10x2x1
0.6
1.6
26.4
1.8
33.2
1746
500
12x2x1
0.6
1.6
27.2
1.8
34.0
1848
500
16x2x1
0.6
29.7
1.9
37.5
2400
500
20x2x1
0.6
32.7
1.9
40.5
2705
500
24x2x1
0.6
2.5
36.3
2.0
45.3
3516
500
30x2x1
0.6
2.5
38.2
2.1
47.4
3867
500
Instrument Cables
304
1x2x1.5
0.6
0.9
13.3
1.4
17.9
523
1000
2x2x1.5
0.6
1.25
18.0
1.6
23.7
890
1000
3x2x1.5
0.6
1.25
18.8
1.6
24.5
973
500
4x2x1.5
0.6
1.25
20.2
1.6
25.9
1087
500
5x2x1.5
0.6
1.6
21.7
1.7
28.3
1376
500
6x2x1.5
0.6
1.6
23.2
1.7
29.8
1505
500
7x2x1.5
0.6
1.6
23.2
1.7
29.8
1551
500
10x2x1.5
0.6
28.5
1.9
36.3
2235
500
12x2x1.5
0.6
29.4
1.9
37.2
2372
500
16x2x1.5
0.6
32.2
1.9
40.0
2722
500
20x2x1.5
0.6
2.5
36.0
2.1
45.2
3585
500
24x2x1.5
0.6
2.5
39.9
2.1
49.1
4079
500
30x2x1.5
0.6
2.5
42.1
2.2
51.5
4550
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY , PiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
14.6
1.5
19.4
599
1000
2x2x2.5
0.7
1.25
20.2
1.6
25.9
1041
500
3x2x2.5
0.7
1.25
21.2
1.7
27.1
1161
500
4x2x2.5
0.7
1.6
22.9
1.7
29.5
1479
500
5x2x2.5
0.7
1.6
24.6
1.8
31.4
1646
500
6x2x2.5
0.7
1.6
26.6
1.8
33.4
1821
500
7x2x2.5
0.7
1.6
26.6
1.8
33.4
1889
500
10x2x2.5
0.7
33.3
2.0
41.3
2786
500
12x2x2.5
0.7
34.4
2.0
42.4
2999
500
16x2x2.5
0.7
2.5
38.2
2.1
47.4
3949
500
20x2x2.5
0.7
2.5
42.2
2.2
51.6
4540
250
24x2x2.5
0.7
3.15
46.9
2.4
58.0
5899
250
30x2x2.5
0.7
3.15
49.5
2.4
60.6
6507
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
305
KCI
RE-2X(St)(L)2Y4YRY , TiMF
Kerman & Kavian Cable Industries ( KCI )
EN 50288-7 (500 V)
Conductor
Black,White,Red (Numbered)
Insulation
Cable Unit
Individual Element
Screen
Collective (Overall )
Screen
Multi-Layer Sheath
Armour
Outer Sheath
+90 oC
Instrument Cables
XLPE
Triple (Multi-Triple Cable)
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape + Polyester Tape
Polyester tape + Drain wire (Tinned copper) +
Al.Polyester Tape
Aluminium copolymer Tape Bonded to HDPE
Sheath + Polyamide Extruded Layer
Galvanized Steel Wires
Extruded PVC
IEC 60332-1
Criteria
Blue,White,Red (Numbered)
Screened
10x O.D
Standard Values
Armoured
Unit
Nominal
0.5
0.75
1.5
2.5
mm
Conductor DC Resistance
@ 20oC
max.
36.7
25.0
18.5
12.3
7.4
Ohm/kM
Insulation resistance
min.
1000
MOhm x
km
Mutual capacitance
max.
150
nF/km
Capacitance unbalance
max.
500
pF/500m
L/R (ratio)
max.
306
25
25
25
40
60
microH/
Ohm
Test voltage :
core to core
for 1
minute
K.V
500
core to screen
Operating voltage U(rms)
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.6
0.9
12.3
1.4
16.9
466
1000
2x3x0.5
0.6
1.25
16.6
1.5
22.1
790
1000
3x3x0.5
0.6
1.25
17.3
1.6
23.0
864
1000
4x3x0.5
0.6
1.25
18.5
1.6
24.2
949
1000
5x3x0.5
0.6
1.25
19.8
1.6
25.5
1035
500
6x3x0.5
0.6
1.25
21.2
1.6
26.9
1123
500
7x3x0.5
0.6
1.25
21.2
1.6
26.9
1154
500
10x3x0.5
0.6
1.6
25.8
1.8
32.6
1676
500
12x3x0.5
0.6
1.6
26.5
1.8
33.3
1769
500
16x3x0.5
0.6
29.0
1.9
36.8
2293
500
20x3x0.5
0.6
31.9
1.9
39.7
2579
500
24x3x0.5
0.6
2.5
35.4
2.0
44.4
3354
500
30x3x0.5
0.6
2.5
37.3
2.1
46.5
3679
500
1x3x0.75
0.6
0.9
12.8
1.4
17.4
495
1000
2x3x0.75
0.6
1.25
17.5
1.6
23.2
855
1000
3x3x0.75
0.6
1.25
18.3
1.6
24.0
931
1000
4x3x0.75
0.6
1.25
19.6
1.6
25.3
1026
500
5x3x0.75
0.6
1.25
21.0
1.6
26.7
1124
500
6x3x0.75
0.6
1.6
22.5
1.7
29.1
1413
500
7x3x0.75
0.6
1.6
22.5
1.7
29.1
1453
500
10x3x0.75
0.6
1.6
27.5
1.8
34.3
1852
500
12x3x0.75
0.6
28.3
1.8
35.9
2225
500
16x3x0.75
0.6
31.0
1.9
38.8
2557
500
20x3x0.75
0.6
34.6
2.0
42.6
2963
500
24x3x0.75
0.6
2.5
38.3
2.1
47.5
3793
500
30x3x0.75
0.6
2.5
40.4
2.2
49.8
4219
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
307
KCI
RE-2X(St)(L)2Y4YRY , TiMF
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
mm
mm
Kg/Km
meter
0.6
0.9
13.1
1.4
17.7
515
1000
2x3x1
0.6
1.25
18.2
1.6
23.9
905
1000
3x3x1
0.6
1.25
19.0
1.6
24.7
991
500
4x3x1
0.6
1.25
20.4
1.6
26.1
1097
500
5x3x1
0.6
1.6
22.0
1.7
28.6
1388
500
6x3x1
0.6
1.6
23.6
1.7
30.2
1518
500
7x3x1
0.6
1.6
23.6
1.7
30.2
1567
500
10x3x1
0.6
29.0
1.9
36.8
2283
500
12x3x1
0.6
29.8
1.9
37.6
2424
500
16x3x1
0.6
32.7
1.9
40.5
2781
500
20x3x1
0.6
2.5
36.5
2.1
45.7
3667
500
24x3x1
0.6
2.5
40.5
2.1
49.7
4169
500
30x3x1
0.6
2.5
42.7
2.2
52.1
4611
250
Instrument Cables
308
1x3x1.5
0.6
0.9
13.8
1.5
18.6
563
1000
2x3x1.5
0.6
1.25
19.4
1.6
25.1
997
500
3x3x1.5
0.6
1.25
20.4
1.6
26.1
1101
500
4x3x1.5
0.6
1.6
21.9
1.7
28.5
1411
500
5x3x1.5
0.6
1.6
23.6
1.7
30.2
1560
500
6x3x1.5
0.6
1.6
25.4
1.8
32.2
1741
500
7x3x1.5
0.6
1.6
25.4
1.8
32.2
1807
500
10x3x1.5
0.6
31.4
1.9
39.2
2589
500
12x3x1.5
0.6
32.4
1.9
40.2
2793
500
16x3x1.5
0.6
2.5
36.0
2.1
45.2
3704
500
20x3x1.5
0.6
2.5
40.2
2.2
49.6
4300
500
24x3x1.5
0.6
3.15
44.2
2.3
55.1
5496
250
30x3x1.5
0.6
3.15
47.0
2.4
58.1
6212
250
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
RE-2X(St)(L)2Y4YRY , TiMF
mm
mm
Kg/Km
meter
mm
Standard
Packing Length
mm
Weight
Diameter Under
Armour
mm
Overall
Diameter
Armour Wire
Diameter
mm2
Sheath thickness
Insulation
thickness
EN 50288-7 (500 V)
0.7
0.9
15.1
1.5
19.9
650
1000
2x3x2.5
0.7
1.6
21.9
1.7
28.5
1349
500
3x3x2.5
0.7
1.6
23.1
1.7
29.7
1504
500
4x3x2.5
0.7
1.6
25.0
1.8
31.8
1719
500
5x3x2.5
0.7
1.6
27.0
1.8
33.8
1926
500
6x3x2.5
0.7
29.2
1.9
37.0
2405
500
7x3x2.5
0.7
29.2
1.9
37.0
2503
500
10x3x2.5
0.7
2.5
36.8
2.1
46.0
3705
500
12x3x2.5
0.7
2.5
38.4
2.1
47.6
4035
500
16x3x2.5
0.7
2.5
42.3
2.2
51.7
4743
250
20x3x2.5
0.7
3.15
47.3
2.4
58.4
6228
250
24x3x2.5
0.7
3.15
52.5
2.5
63.8
7125
250
30x3x2.5
0.7
3.15
55.5
2.6
67.0
8013
250
www.kermancableind.com
Low smoke
Acc to IEC 61034
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
309
KCI
Railway Signal Cable
VDE 0816-2
A-2YYBY
AJ-2Y(St)YBY Multi-Core
AJ-2YDYBY Multi-Core
AJ-2Y(St)YBY Multi-Quad
AJ-2YDYBY Multi-Quad
KCI
1) Conductor
The conductor is plain solid annealed copper ; usually 0.9 , 1.4 mm (0.8 , 1.8 mm also available).
The conductors must be of soft copper and of completely satisfactory quality, The breaking elongation
of the conductors in the cable must be at least 15%. Any joints present must not impair the completely
satisfactory nature of the conductor. The tensile strength of a joint within a conductor must be at least 90%
of the tensile strength of that conductor without a joint.
2) Insulation
The PE insulation must comply with compound 2YI1 in accordance with DIN
VDE 0207
Instrument Cables
PE : Polyethylene
3)Cabling element
A cabling element shall be
an insulated conductor (core) to build up a multi-core cable
a pair of two insulated conductors twisted together and designated wire a and wire b
a quad (star quad) of four insulated conductors twisted together and designated wire a, wire b, wire c
and wire d respectively.
The stranding components are counted successively in the same direction through all the layers, starting
with the first layer (inner layer). In doing this, start from the initial component in each layer
312
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
Kerman & Kavian Cable Industries ( KCI )
4)Stranding
The cable elements shall be formed into a number of sub-units or units which can be stranded into a regular
make up to produce the required number of cores , pairs or Quads .
5)Filling
For filled cables (if Requested) , the interstices of the cable core shall be filled continuously with a
compound suitable to prevent water penetration within the cable.
6)Core protection
The core of the cable may have a protective layer (e.g. a helical or longitudinal lapping of one or more tapes).
7)Shield (protection against electromagnetic fields)
The Shield of cable is selected to comply requirements of requested reduction factor . It could be ;
Copper Tapes or Copper Wires .
Tape
Wires
Tape Armour
Instrument Cables
Wire Armour
9)Sheath
The inner-sheath and outer-sheath of cable is usually PVC.
The PVC sheath must comply with compound type YM1 in accordance
with DIN VDE 0207 Part 5.
-Optional : A moisture barrier aluminium laminated polyethylene sheath
construction is specified for both underground and aerial cables. This type
of sheath will also provide screening.
313
-Optional : A lead sheath could be provided for extra shield and protection
against penetration of liquids and chemicals to cable core.
Lead Sheath (Lead Cover)
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
KCI
A-2YYBY
Construction :
Conductor
Insulation
Color Code
Bedding
Armour
Sheath
Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics
Conductor Size
Standard value
0.9 mm
Max 28.9
1.4 mm
Max 11.9
Min 5
Gohm x km
0.9 mm
Max 100
1.4 mm
Max 120
nF/km
at 800 - 1000 Hz
Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance
Unit
Ohm/kM
Dielectric strength
2
Number of Cores x
Conductor Diameter
Armour Tape
Thickness
Sheath thickness
Overall
Diameter
Weight
Standard
Packing Length
2500
Diameter Under
Armour
Instrument Cables
314
2500
wire/wire
wire/screen
mm
mm
mm
mm
mm
Kg/Km
meter
2x1x0.9 S(2B0.5)
8.1
0.5
2.6
15.3
398
1000
4x1x0.9 S(2B0.5)
8.9
0.5
2.6
16.1
443
1000
6x1x0.9 S(2B0.5)
9.8
0.5
2.6
17.0
499
1000
8x1x0.9 S(2B0.5)
11.1
0.5
2.6
18.3
569
1000
12x1x0.9 S(2B0.5)
12.2
0.5
2.6
19.4
640
1000
30x1x0.9 S(2B0.5)
16.3
0.5
2.6
23.5
945
1000
50x1x0.9 S(2B0.5)
20.1
0.5
2.6
27.3
1261
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
Kerman & Kavian Cable Industries ( KCI )
A-2YYBY
Construction :
Conductor
Insulation
Color Code
Bedding
Armour
Sheath
Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics
Conductor Size
Standard value
0.9 mm
Max 28.9
1.4 mm
Max 11.9
Min 5
Gohm x km
0.9 mm
Max 100
1.4 mm
Max 120
nF/km
at 800 - 1000 Hz
Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance
Unit
Ohm/kM
Dielectric strength
2500
Sheath thickness
Overall
Diameter
Weight
Standard
Packing Length
mm
mm
mm
mm
mm
Kg/Km
meter
4x1x1.4
10.4
0.5
2.6
17.6
543
1,000
5x1x1.4
11.2
0.5
2.6
18.4
593
1,000
8x1x1.4
12.4
0.5
1.8
18.0
622
1,000
10x1x1.4
14.5
0.5
2.6
21.7
813
1,000
16x1x1.4
16.4
0.5
2.6
23.6
995
1,000
20x1x1.4
18.0
0.5
2.6
25.2
1135
500
30x1x1.4
20.8
0.5
2.6
28.0
1416
500
33x1x1.4
21.6
0.5
2.6
28.8
1504
500
40x1x1.4
23.2
0.5
2.6
30.4
1685
500
50x1x1.4
26.0
0.5
2.6
33.2
1986
500
56x1x1.4
26.8
0.5
2.6
34.0
2117
500
60x1x1.4
27.5
0.5
2.6
34.7
2217
500
65x1x1.4
28.4
0.5
2.6
35.6
2337
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
Number of Cores x
Conductor Diameter
Armour Tape
Thickness
2500
Diameter Under
Armour
wire/wire
wire/screen
315
KCI
AJ-2Y(St)YBY
Construction :
Conductor
Insulation
Color Code
Inner Covering
Shield
Bedding
Armour
Sheath
Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics
Conductor Size
Standard value
0.9 mm
Max 28.9
1.4 mm
Max 11.9
Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance
Unit
Ohm/kM
Min 5
Gohm x km
0.9 mm
Max 100
1.4 mm
Max 120
nF/km
at 800 - 1000 Hz
Dielectric strength
2
Number of Cores x
Conductor Diameter
Armour Tape
Thickness
Sheath thickness
Overall
Diameter
Weight
Standard
Packing Length
2500
Diameter Under
Armour
Instrument Cables
316
2500
wire/wire
wire/screen
mm
mm
mm
mm
mm
Kg/Km
meter
2x1x0.9 S(2B0.5)
9.1
0.5
1.8
14.7
412
1000
4x1x0.9 S(2B0.5)
9.9
0.5
1.8
15.5
458
1000
8x1x0.9 S(2B0.5)
12.2
0.5
1.8
17.8
590
1000
12x1x0.9 S(2B0.5)
13.2
0.5
1.8
18.8
659
1000
8x1x1.4 S(2B0.5)
14.7
0.5
1.8
20.3
4373
1,000
12x1x1.4 S(2B0.5)
16.1
0.5
1.8
21.7
896
1,000
16x1x1.4 S(2B0.5)
17.6
0.5
1.8
23.2
896
1,000
21x1x1.4 S(2B0.5)
19.2
0.5
2.0
25.2
1203
1,000
27x1x1.4 S(2B0.5)
21.3
0.5
2.0
27.3
1203
1,000
33x1x1.4 S(2B0.5)
22.8
0.5
2.0
28.8
1203
1,000
40x1x1.4 S(2B0.5)
25.2
0.5
2.0
31.2
1203
500
48x1x1.4 S(2B0.5)
27.3
0.5
2.0
33.3
1203
500
56x1x1.4 S(2B0.5)
28.8
0.5
2.2
35.2
2306
500
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
Kerman & Kavian Cable Industries ( KCI )
AJ-2YDYBY
Construction :
Conductor
Insulation
Color Code
Inner Covering
Shield
Bedding
Armour
Sheath
Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics
Conductor Size
Standard value
0.9 mm
Max 28.9
1.4 mm
Max 11.9
Conductor DC
resistance, max.
Insulation resistance
Mutual capacitance
Unit
Ohm/kM
Min 5
Gohm x km
0.9 mm
Max 100
1.4 mm
Max 120
nF/km
at 800 - 1000 Hz
Dielectric strength
2500
Sheath thickness
Overall
Diameter
Weight
Standard
Packing Length
mm
mm
mm
mm
mm
Kg/Km
meter
2x1x0.9 S(2B0.5)
11.1
0.5
1.8
16.7
412
1000
4x1x0.9 S(2B0.5)
11.9
0.5
1.8
17.5
699
1000
8x1x0.9 S(2B0.5)
14.2
0.5
1.8
19.8
886
1000
12x1x0.9 S(2B0.5)
15.2
0.5
1.8
20.8
971
1000
16x1x0.9 S(2B0.5)
16.3
0.5
2.0
22.3
1180
1000
12x1x1.4 S(2B0.5)
18.1
0.5
2.0
24.1
1292
1,000
16x1x1.4 S(2B0.5)
19.6
0.5
2.0
25.6
1463
1,000
21x1x1.4 S(2B0.5)
21.2
0.5
2.0
27.2
1203
1,000
27x1x1.4 S(2B0.5)
24.1
0.5
2.0
30.1
1203
1,000
33x1x1.4 S(2B0.5)
25.6
0.5
2.0
31.6
1203
500
40x1x1.4 S(2B0.5)
27.2
0.5
2.0
33.2
1203
500
48x1x1.4 S(2B0.5)
29.3
0.5
2.2
35.7
1203
500
56x1x1.4 S(2B0.8)
30.8
0.8
2.2
38.4
2306
500
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
Number of Cores x
Conductor Diameter
Armour Tape
Thickness
2500
Diameter Under
Armour
wire/wire
wire/screen
317
KCI
AJ-2Y(St)YBY
Construction :
Conductor
Insulation
Color Code
Inner Covering
Shield
Bedding
Armour
Sheath
Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics
Conductor Size
Standard value
Unit
0.9 mm
1.4 mm
Max 56.6
Max 23.4
Min 5
Max 45
Max 50
Ohm/kM
Conductor Loop
resistance, max.
Insulation resistance
0.9 mm
1.4 mm
Mutual capacitance
Gohm x km
nF/km
at 800 - 1000 Hz
Dielectric strength
wire/wire
wire/screen
2500
2500
at 800 - 1000 Hz
Max 800
Number of Cores x
Conductor Diameter
Standard
Packing Length
Max 100
Weight
Overall
Diameter
pf/300 m
Sheath thickness
Max 400
Max 300
Armour Tape
Thickness
Diameter Under
Armour
Instrument Cables
Capacitance unbalance
mm
mm
mm
mm
mm
Kg/Km
meter
1x4x1.4 S(2B0.5)
15.2
0.5
2.6
22.4
880
1000
3x4x1.4 S(2B0.5)
21.3
0.5
2.6
28.5
1371
1000
5x4x1.4 S(2B0.5)
24.5
0.5
2.6
31.7
1719
1000
7x4x1.4 S(2B0.5)
26.3
0.5
2.6
33.5
1949
1,000
8x4x1.4 S(2B0.5)
28.0
0.5
2.6
35.2
2121
1,000
10x4x1.4 S(2B0.5)
30.6
0.5
2.6
37.8
2414
1,000
318
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
Kerman & Kavian Cable Industries ( KCI )
AJ-2YDYBY
Construction :
Conductor
Insulation
Color Code
Inner Covering
Shield
Bedding
Armour
Sheath
Color Code: Generally as VDE 0816 (also acc to Iran Railway standard)
Characteristics
Conductor Size
Standard value
Unit
0.9 mm
1.4 mm
Max 56.6
Max 23.4
Min 5
Max 45
Max 50
Ohm/kM
Conductor Loop
resistance, max.
Insulation resistance
Mutual capacitance
0.9 mm
1.4 mm
Gohm x km
nF/km
at 800 - 1000 Hz
Dielectric strength
wire/wire
wire/screen
2500
2500
Max 800
Number of Cores x
Conductor Diameter
Standard
Packing Length
at 800 - 1000 Hz
Weight
Max 100
Overall
Diameter
Sheath thickness
pf/300 m
Armour Tape
Thickness
Max 400
Max 300
Diameter Under
Armour
mm
mm
mm
mm
mm
Kg/Km
meter
1x4x1.4 S(2B0.5)
13.9
0.5
1.8
19.5
567
1000
3x4x1.4 S(2B0.5)
19.3
0.5
2.0
25.3
931
1000
5x4x1.4 S(2B0.5)
22.8
0.5
2.0
28.8
931
1000
7x4x1.4 S(2B0.5)
29.6
0.5
2.2
36.0
2199
1000
8x1x1.4 S(2B0.5)
16.7
0.5
1.8
22.3
4373
1000
10x4x1.4 S(2B0.8)
33.8
0.8
2.2
41.4
2096
1000
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
Instrument Cables
Capacitance unbalance
319
KCI
Appendix
Used Symbols (In cables datasheets)
Color Coding of pairs acc to IEC 60708 , 60189
Shield Effectiveness
SCREEN Selection guide for Instrument cables
Types of Noise and Their Effects on the cables
Reduction Factor of Screen
KCI
Mechanical Protection
Fire Resistant
Low Smoke
Instrument Cables
Flame Retardant
Flexibility
322
Protection against
Electromagnetic Fields
UV / Weather Resistant
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
Wire a
Wire b
Blue
Orange
White
Green
Brown
Grey
Blue
Orange
Red
Green
Brown
10
Grey
11
Blue
12
Orange
13
Black
Green
14
Brown
15
Grey
16
Blue
17
Orange
18
Yellow
Green
19
Brown
20
Grey
21
Blue
22
Orange
23
Violet
Green
24
Brown
25
Grey
Instrument Cables
Pair No
KCI
323
www.kermancableind.com
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
KCI
Shield Effectiveness
Kerman & Kavian Cable Industries ( KCI )
Transfer Impedance
Transfer impedance is a fundamental value of a shields Performance.
Transfer impedance relates a current on one surface of the shield To the voltage drop generated by this current
on the opposite surface of the shield. This value depends solely on the shield
construction.
Transfer impedance test data is obtained with a terminated Triaxial test fixture. This test method, which is a
modification of An existing IEC test procedure, is the one that was proposed by Kenneth Simons.
Instrument Cables
Zt = ( 1 / I0 ) x ( dV / dx )
Where I0 is a longitudinal disturbing current generated on one surface (either the inner or the outer surface)
of the shield and dv /dx is the longitudinal voltage per unit length, generated by I0 , appearing on the opposite
surface of the shield.
In the terminated triaxial test system, the test cable center conductor and the shield form an inner terminated
triaxial test system, the test cable center conductor and the shield form an inner transmission system, with the
shield and the outer concentric tube forming an outer transmission system .
The outer system is driven by a generator and creates a current I0 on the outer surface of the shield. This
current causes a voltage difference on the opposite surface shown as V1, and V2 over a length of shield X.
This generates signals in the test cable which can be related to the transfer impedance value of the shield.
324
Conclusion :
The lower the value of the transfer impedance, the more effective the shielding.
The transfer impedance value theoretically can be used to determine absolute interference levels.
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
www.kermancableind.com
Low frequency
performance
High frequency
performance
Good
----
Good
Good
Excellent
Good
Excellent
Excellent
Instrument Cables
325
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
KCI
For transducer connection to the instrument , the cable transmits a very low e.m.f. signal.
A noise free signal is important to avoid mistakes.
Thus the cable must be screened against static or magnetic fields which can induce unwanted e.m.f.
There are four different sources of noise, as follows:
Static Noise
This is interference caused by coupling of capacity
between
external electrical field from power line or another
voltage source and the cable. Interposing a single shield
which forms a capacitor when connected to the earth.
A shield of aluminium/polyester, 100% coverage is
recommended.
Magnetic Noise
Generally low frequency electromagnetic field due
to power cable, motor, ctc. Can induce e.m.f. into the
instrumentation cable. The twisting of conductors provides
a good reduction of the magnetic noise. Other reduction
are given by steel conduit, armours (high inductance
material).Is some particular cases low resisting screen(i.e.
copper braids, copper tapes) may be necessary.
Common-Mode Noise
Instrument Cables
Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN
KCI
External interference
Screening against external interference has to take the influence of both electric and magnetic interference into
account and make a distinction between LF and HF fields.The design of the required screen depends on the
type and strength of interference.
Requirements for effective screening in the HF-range are basically a low DC resistance and maximum
coverage of the screen .
Reduction factor
rc
rc > 0.9
Characteristic of Screening
Material
High DC resistance
rc =0.9 0.7
Low DC resistance
rc = 0.7 0.3
Low DC resistance in
combination of high inductance
rc < 0.3
www.kermancableind.com
Instrument Cables
Email : info@kermancableind.com Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427
327