Depending on the basic device category, you must first maintain the following data in order to create a device
category:
Meter
Remote meter
Corrector
Other
Command group
o
Winding group
o
Requirements
In order to serialize devices of a device category, the reference material master must specify a
serial number profile.
In order to define a serial number profile, you must first make the following settings:
If you wish to indicate that a device is "subject to external certification", table TE270 must be
maintained.
If you do not want to use standard functions (inventory management, warehouse management,
classification system) for device management, you must enter a reference material that meets your
requirements.
If you want to use the standard fuctions, you should first define a material in the standard system for
each device category that you create, and then specify it in the Device category field on the initial
screen of Create device category.
You must maintain the following views if you execute the function Create material in the standard
system for IS-U purposes:
o
Basic data 1
Accounting 1 (only if you have selected the Copy valuation view from material
reference field)
you define the loss determination groups for voltage losses of a power transformer.
You may define a function class for several construction classes, but you may not define different
functions for the same construction class.
Register group
| Register category
| Dimension
| POWER
| POWER
01 | 0002
02 | 0001
| Gas meter
02 | 0002
| Corrector
DC = Division category
The following search terms are dependent on division category: register group, input/output group
and inspection point group
whereas the search terms command group and winding group are not dependent on division
category. This is because command groups are only used in audiofrequency ripple control receivers
(ARCR) and winding groups are only used in transformers, which both belong to the division for
electricity.
Register factor
Constant dependent on the construction type. It is multiplied by the meter reading result to obtain the actual
consumption
Dependencies
If you enter several meter readings here, you can calculate an average value in billing.
Transformation ratio
The transformation ratio specifies the conversion factor used by the register to which a transformer is
connnected.
The transformation ratio can be specified for the device category, for the device, and for register.
The transformation ratio for the register overwrites the ratio for the device and
the ratio for the device overwrites the ratio for the device category.
The transformation ratio can only be specified if the measuring type of the device category is 1 or 2 (i.e. for
semi-indirect or indirect measuring).
Specify the respective absolute values (e.g. 10,000 V, 5,800 V) since the program uses these in the calculation
of the transformation ratio.
During billing, rate determination is not carried out for the rate type of the register. The rate of
the register is not billed unless it is determined via another billing-relevant register.
Dependencies
The N (register not relevant for billing) field is only effective when the Do not read (do not read
register) field is not selected.
If the N (register not relevant for billing) field is selected for all registers and no rate type is specified in
the installation or rate category facts, billing is terminated as no rate is found.