Sei sulla pagina 1di 2

abcd

Date : 03.06.2011

TYPICAL STORAGE PROCEDURE FOR ESP


DESCRIPTION

STORAGE INSTRUCTION
To be stored in covered space
To be stacked in Open Space on Wooden sleeper/RCC pedestal (min 400 mm thick). The necessary
surface preparation for the ground and proper inclination of the stacking is to be done to avoid rain
water storing / seepage.
-doTo be stored in covered space
To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage. Insulator housing door to be kept in top
side to avoid entry of water.
-do-do-doTo be stacked in Open Space on Wooden sleeper/RCC pedestal (min 400 mm thick). The necessary
surface preparation for the ground and proper inclination of the stacking is to be done to avoid rain
water storing / seepage.
-do-do-doTo be stored in covered space
To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing / seepage.

SLIDE BEARING/ROLLER BEARING


ESP CASING
ESP HOPPER
BUSHING INSULATORS
INSULATOR HOUSING
INLET GAS DISTRIBUTION SCREEN
INLET GAS DISTRIBUTION RAPPING
INLET GAS DISTRIBUTION DRIVE
HOPPER GAS SCREEN
EMITTING FRAMEWORK
EMITTING SUSPENSION
INLET & OUTLET FUNNELS
EMITTING ELECTRODES
EMITTING RAPPING MECHANISM
DRIVING ARRANGEMENT
RAPPING

FOR

EMITTING

COLLECTING SUSPENSION

COLLECTING PLATES

BUS DUCT
INSPECTION DOOR
COLLECTING RAPPING MECHANISM
COLLECTING RAPPING DRIVE
HT BOLTS/NUTS
OUTLET GAS DISTRIBUTION SCREEN
OIL PANS
OUTER ROOF
HOPPER HEATING JACKET
RAPPING GEAR MOTOR
T R SET
HOPPER HEATERS
EARTHING ROD
SAFETY INTERLOCK
HT ISOLATORS & BUS COUPLER
DUST LEVEL INDICATOR
TEMPERATURE SWITCH
INSULATION ACCESSORIES
ESP CONTROLLER
SUPP. INSULATOR
SHAFT INSULATOR
RTU+MODULAR JACK+RTU JACK CABLE
COMMUNICATION CABLE

-doTo be stacked in Open Space on Wooden sleeper/RCC pedestal (min 400 mm thick). The necessary
surface preparation for the ground and proper inclination of the stacking is to be done to avoid rain
water storing and seepage.
To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage.
To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage.
To be stored in covered space
To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage.
To be stored in covered space
To be stored in covered space
To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage.
-do-do-doTo be stored in covered stores
To be stored in covered stores
To be stored in covered stores
To be stored in covered stores
To be stored in covered stores
To be stored in covered stores
To be stored in covered space
To be stored in covered space
To be stored in covered space
To be stored in covered space
To be stored in covered space
To be stored in covered space
To be stored in covered space
To be stored in covered space

Page 1 of 2

abcd
Date : 03.06.2011

TYPICAL STORAGE PROCEDURE FOR ESP


DESCRIPTION

ROTARY AIR LOCK

STORAGE INSTRUCTION

To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal


(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage. To be stored in covered space.

GEARED MOTOR FOR ROTARY AIR LOCK

To be stored in covered space


To be stored in Semi-covered space with tarpaulin/plastic sheets on Wooden sleeper/RCC pedestal
EXPANSION JOINT FOR MHS
(min 400 mm thick). The necessary surface preparation for the ground and proper inclination of the
stacking is to be done to avoid rain water storing and seepage.
NON METALLIC EXPANSION JOINTS
To be stored in covered space
INSULATION ACCESSORIES
To be stored in covered stores
TEMPERATURE TRANSMITTER
-doTEMPERATURE GAUGE
-doPRESSURE TRANSMITTER
-doPRESSURE GAUGE
-doJUNCTION BOXES
-doZERO SPEED MONITOR
-doTo be stacked in Open Space on Wooden sleeper/RCC pedestal (min 400 mm thick). The necessary
DUCTING
surface preparation for the ground and proper inclination of the stacking is to be done to avoid rain
water storing and seepage.
To be stacked in Open Space on Wooden sleeper/RCC pedestal (min 400 mm thick). The necessary
ESP SUPPORT STRUCTURE
surface preparation for the ground and proper inclination of the stacking is to be done to avoid rain
water storing and seepage.
MONORAIL FOR TR SET HANDLING
-doTo be stacked in Open Space on Wooden sleeper/RCC pedestal (min 400 mm thick). The necessary
STAIRWAYS - GROUND TO ESP CASING DOOR
surface preparation for the ground and proper inclination of the stacking is to be done to avoid rain
LEVEL
water storing and seepage.
STAIRWAY - ESP CASING DOOR LEVEL TO
-doESP ROOF

Page 2 of 2

Potrebbero piacerti anche