Sei sulla pagina 1di 1

SAMSUNG OPTICAL CABLE

All Dielectric Self-Supporting Cable


Loose Tube ADSS Cable_Aerial
SAMSUNGs ADSS Cables are designed for installation on wooden poles, concrete poles or lattice towers
along power lines, railways or telecommunication links.
As the cable does not contain any metallic elements, it is to be installed on medium and high voltage lines, to
prevent dry-band arcing. Track resistant sheath material and software to calculate optimum placement on the
towers make this cable usable for line voltages of up to 400 KV.
Up to 144 fibers
High resistance to tracking effect provides long operating lifetime
SZ stranding design allows for easy mid-span access and isolates fibers from installation and environmental rigors
Drycore design for excellent water blocking performance and easier handling
Minimized additional loads due to small diameter and lightweight with the high strength aramid yarns
Custom designs available ***
Complies with IEEE P-1222, the recognized standard for ADSS cable
*** The sheath material (MDPE or TRPE) and the location of the cable on structures that support 110KV or higher circuits should be reviewed prior to installation.

CABLE PROPERTIES

Single Jacket Type

Single Jacket Type

Fiber Count
Outer Diameter (mm)
MDPE
Cable Weight (kg / km)
TRPE
Maximum operating load (kN)
Maximum breaking load (kN)
Short term (loaded): 15*OD
Minimum bending
radius (mm)
Long term (installed): 10*OD
Operation / Storage
Temperature (C)
Installation

2 ~ 36
11.4
100
107
4
13.0
171
114

2 ~ 72
12.2
114
122
4
13.6
183
122

74 ~ 96
13.9
147
156
4
14.0
209
139

144
15.8
192
201
6
15.4
237
158

-40 ~ +70
-20 ~ +70

Double Jacket Type


Double Jacket Type

Gel-filled buffer tube


Colored optical fiber
Dielectric central member
Water swellable tape
Water swellable yarn
Inner jacket
Dielectric strength member
Outer jacket

*** Drawings are not to scale.

Fiber Count
Outer Diameter (mm)
MDPE
Cable Weight (kg / km)
TRPE
Maximum operating load (kN)
Maximum breaking load (kN)
Short term (loaded): 15*OD
Minimum
bending radius (mm) Long term (installed): 10*OD
Operation / Storage
Temperature (C)
Installation
Fiber Count
Outer Diameter (mm)
MDPE
Cable Weight (kg / km)
TRPE
Maximum operating load (kN)
Maximum breaking load (kN)
Short term (loaded): 15*OD
Minimum
bending radius (mm) Long term (installed): 10*OD
Operation / Storage
Temperature (C)
Installation

2 ~ 36
12.9
128
137
4
13.4
194
129

14.1
151
161
12
35.7
212
141

15.3
176
186
20
59.9
230
157

15.4
180
190
4
13.2
231
154

74 ~ 96
16.3
17.3
202
225
213
237
12
20
35.5
58.5
245
230
163
157

16.2
13.8
199
144
210
154
28
4
82.8
14.0
243
207
162
138
-40 ~ +70
-20 ~ +70
18.1
19.2
247
280
260
293
28
8
81.5
23.1
272
288
181
192
-40 ~ +70
-20 ~ +70

38 ~ 72
14.8
15.8
166
189
176
200
12
20
35.1
58.1
222
237
148
158

16.8
212
224
28
81.0
252
168

98 ~ 144
19.9
20.7
302
323
316
338
16
24
46.5
69.5
299
311
207
207

21.4
345
360
32
92.6
321
214

Tested in accordance with IEC 60794-1

Note
Fiber colors by IEC60304 - Blue / Orange / Green / Brown / Grey / White / Red / Black / Yellow / Violet / Pink / Aqua
Diameter represents a nominal value and may vary by 5%.
Sheath marking legend - hot foil stamp (indented)
Ex) Manufacturing year (ex. 2013) SAMSUNG ADSS SM 24 = length marking =

2013 Samsung Electronics Co. Ltd. All rights reserved.


Samsung Electronics reserves the right to modify the design, packing, specifications and features shown herein, without prior notice or obligation.

www.samsung.com/global/business/fiberoptics

Potrebbero piacerti anche