Single-phase
and three-phase
UPS from 8 to 40 kVA
for critical IT and light industrial applications
Easy to install.
Unique to the market with its highly
compact size.
Flexible back-up times: different back-up
time configurations are available either
within the UPS standard cabinet or by
using taller UPS cabinets, without changing
the floor space (W = 444, D = 795 mm).
power and availability (redundancy) can
be extended by placing up to 2 units in
parallel.
MASTE 049 B
Your protection
for
44
Single-phase and
three-phase UPS
Range
from 8 to 40 kVA
Model
BC 108
BC 110
BC 112
BC 115
BC 120
BC 310
BC 312
BC 315
BC 320
BC 330
BC 340
MASTERYS BC
In/Out
Typical B.U.T.(1)
M
60
45
35
27
19
45
35
27
19
11
7
kVA
1/1 or 3/1(2)
1/1 or 3/1(2)
3/1
3/1
3/1
3/3
3/3
3/3
3/3
3/3
3/3
S
25
20
16
11
7
20
16
11
7
-
8
10
12
15
20
10
12
15
20
30
40
T
95
60
55
63
46
60
55
63
46
27
19
Electrical options
Technical data
kVA
kW
Input / output: 1 / 1
Input / output: 3 / 1
Input / output: 3 / 3
Parallel configuration
INPUT
8
5.6
10
7
(1)
(1)
(1)
(1)
Automaticbypass
Internalmaintenancebypass
Overload
Crest factor
PFacceptablewithoutde-rating
EFFICIENCY
Globalefficiency(On-line)
Efficiency in ECO-MODE
ENVIRONMENT
Operatingambienttemperature
Storage temperature range
Relative humidity
Maximum altitude
Noise level (ISO 3746)
UPS CABINET
20
16
30
24
40
32
(1ph+N)230V20%(upto-40%at50%nominalload);
(3ph+N)400V20%(upto-40%at50%nominalload)
50/60Hz10%
0.99/<6%(2)
0.99/<3%
Input frequency
Powerfactor/THDI
OUTPUT
Output frequency
15
12
up to 2 units
Nominal voltage
Output voltage
12
8.4
ifsingle-phase,230V1%(canbeconfigured208(4)/220/230/240V);
ifthree-phase4001%(360(4)/380/400/415Vconfigurable)
50/60Hz2%(configurablefrom1%to8%withgeneratingset)
Nominaloutputvoltage15%
(configurablefrom10%to20%withgeneratingset)
option
125%for2 ,150%for10
125%for10 ,150%for60
3:1 (complying with IEC 62040-3)
up to 0.9 lead. (up to 0.7 lead for 10 minutes)
upto92%
upto93%
upto98%
CabinettypeM(Medium)
DimensionsWxDxH(mm)
CabinettypeT(Tall)
DimensionsWxDxH(mm)
Weight(withstandardbatteries)(kg)
Degreeofprotection
STANDARDS
Safety
Performance & topology
EMC standard
Produc t certification
IP rating
155
160
175
195
240
IP 20 (according to IEC 60529)
Communication options
ADC interface (configurable voltage-free
contacts).
NET VISION: professional WeB/sNMp
interface for UPS monitoring and shutdown management of several operating
systems.
UNIVISION-PRO: advanced user interface
via serial link and multiple shutdown
management for several operating
systems.
JNC: shutdown client for workstations and
servers for several operating systems.
OPManager: centralized monitoring
program for Windows and Linux via
sNMp.
Remote maintenance
0Cto+40C(15Cto25Cforbestbatterylife)
-5Cto+50C(15Cto25Cforbestbatterylife)
0%-95%withoutcondensation
1000mwithoutde-rating(maximum3000m)
<50dB
< 52 dB
< 55 dB
CabinettypeS(Short)
DimensionsWxDxH(mm)
T.SERVICE:
maintanance
software
for continuous 24 / 7 monitoring of the
SOCOMEC UPS.
315
415
EN62040-1(TVSDcertified),EN60950-1-1
EN 62040-3 [VFI-SS-111]
EN 62040-2
CE
IP 20 (according to IEC 60529)
(3) Back-up time.
(4) @ POUT = 90 % PNOM.
45
Three-phase
UPS
MASTERYS MC
from 60 to 80 kVA
for critical IT and light industrial applications
Easy to install.
Easy to handle (fitted with castors).
Flexible back-up times: wide range of
configurations are availble by using external
battery cabinet (from 10 to 130).
Scalable power or availability (using
redundancy) by placing up to 6 units in
parallel.
Harmonic distortion reduced (THDi < 3 %)
via use of an IGBT rectifier.
Graphic display.
Redundant batteries: the battery packs are
connected to each other in two distinct
strings. If one battery pack in a string is not
functioning, back-up time is still available
from the remaining string.
EXPERT BATTERY SYSTEM for battery
management.
ALWAYS ON MODE energy saving
operation without upstream harmonic
feedback.
ENERGY SAVER power management in
parallel configuration.
GLOBAL SUPPLY SYSTEM generating set
management.
Protection against backfeed on the
upstream network (internal or external)
Separate rectifier supply and bypass
networks.
Internal maintenance manual bypass.
Temperature control of the external battery
cabinet.
46
Your protection
for
Three-phase
UPS
Range
MASTERYS MC
from 60 to 80 kVA
kVA
60
80
Input / output
3/3
3/3
Back-uptimestd
16 *
10 *
Electrical options
Technical data
kVA
kW
Input / output: 3/3
Parallel configuration
INPUT
Nominal voltage
Input frequency
Powerfactor/THDI
OUTPUT
Output voltage
Output frequency
Automaticbypass
Overload
Crest factor
PFacceptablewithoutde-rating
EFFICIENCY
Globalefficiency(On-line)
EfficiencyinECO-MODE
EfficiencyinALWAYS-ONMODE
ENVIRONMENT
Operatingambienttemperature
Storage temperature range
Relativehumidity
Maximumaltitude
Noiselevel(ISO3746)
UPS CABINET
60
48
80
64
up to 6 units
(3ph+N)400V20%(1)(upto-35%at70%nominalload)
50/60Hz10%
0.99/<3%
if1ph+N230V1%(canbeconfigured220/240V)
if3ph+N4001%(1)(380/415Vconfigurable)
50/60Hz2%(canbeconfiguredfrom1%to8%withgenerating
set)
nominaloutputvoltage15%
(configurablefrom10%to20%withgeneratingset)
125%for10 ,150%for60
3:1(complyingwithIEC62040-3)
upto0.9lead.(upto0.7leadfor10minutes)
CabinettypeT(Tall)
DimesnionsWxDxH(mm):444x795x1400
Max.B.U.T.(2)
Weight(kg)
Degreeofprotection
STANDARDS
Safety
PerformanceandTopology
EMCstandard
Productcertification
upto93%
upto98%
upto96%
0Cto+40C(15Cto25Cforbestbatterylife)
-5to+45C(15Cto25Cforbestbatterylife)
0%-95%withoutcondensation
1000mwithoutde-rating(maximum3000m)
<62dB
UPS
(withoutbattery)
16
10
upto130
upto100
200
210
IP20(accordingtoIEC60529)
IEC62040-1(TVSDcertified),IEC60950-1-1
(EN)IEC62040-3[VFI-SS-111]
IEC62040-2(2ndEdition)EN50091-2
CE
Communication options
Remote panel.
ADC interface (configurable voltage-free
contacts).
Profibus interface.
NET VISION: professional WEB / SNMP
interface for UPS monitoring and shutdown management of several operating
systems.
JNC: shutdown client for workstations and
servers for several operating systems.
OPManager: centralized monitoring
program for Windows and Linux via
SNMP.
Remote maintenance
T.SERVICE:
maintenance
software
for continuous 24 / 7 monitoring of the
SOCOMEC UPS.
47
Three-phase
UPS
MASTERYS MC
from 100 to 120 kVA
for critical IT application
Availability
Uptime maximisation.
Redundant parallel.
Enhanced overload capacity.
The high UPS short circuit capability
allows for enhanced downstream fault
discrimination.
Genset compatibility:
Wide range of input voltage and frequency
and full communication with Genset via
GSS interface.
Intelligent component cooling.
Limited thermal stress and longer life of the
components.
Multiprocessor control.
Fully suitable together with STS
architectures.
User friendly.
Intuitive graphical LCD display.
Embedded LAN.
2000 events logs.
Built-in separate input mains.
Fully customisable
Robustness
Steel frame.
High overload capacity in all operating
conditions.
The MASTERYS MC
100-120 kVA series is
certified by TV SD with
regard to product safety
(EN62040-1).
MASTE 050 A
MASTERYS MC efficiency is
verified by TV SD.
48
Your protection
for
>Data centers
>Telecommunications
>Service Sector
Three-phase
UPS
MASTERYS MC
from 100 to 120 kVA
Model
Input / output
KVA
MC+100
MC+120
3/3
3/3
100
120
15
11
Battery cabinet
Size (mm)
Weight (kg)
800 x 830 x 1930
1150
800 x 830 x 1930
1150
Rectier
Battery
Inverter
DEFYS 047 B
Static bypass
Technical data
Sn (kVA)
Pn (kW)
INPUT
Rated voltage
Voltage tolerances
Input frequency
Power factor / THDI
OUTPUT
Voltage
Voltage tolerance
Frequency
Automatic bypass
Total harmonic voltage distortion
Overload @ p.f. 0.8
Overload @ p.f. 0.9
Crest factor
EFFICIENCY
Online mode (TV SD verified)
ECO MODE
ENVIRONMENT
Operating ambient temperature
Relative humidity
Maximum altitude
Noise level (ISO 3746)
UPS CABINET
Dimensions W x D x H (mm)
Weight (kg)
Degree of protection
Colour
STANDARDS
Safety
Performance
EMC standard
Product certification
Maintenance bypass
120
108
400V 3ph +N
20 % without declassing, -40 % with 50 % of Pn
50 / 60Hz 10 %
>0.99 / <3 %
400V 3ph +N 1 % (380 / 415 configurable)
static load 1 %
dynamic load in accordance with VFI-SS-111
50 / 60Hz 2 % (configurable with generator from 1 % to 8 %)
rated voltage output 15 %
(configurable with generator from 10 % to 20 %)
<1 % with linear load / <3 % with nonlinear load
125 % for 10 / 150 % for 60
125 % for 5 / 150 % for 30
3 : 1 (in accordance with (EN) IEC 62040-3)
95.8 % @ 50 % of load
95.5 % @ full load
95.9 % @ 50 % of load
95.2 % @ full load
98 %
Electrical options
Communication options
Remote panel.
ADC interface (configurable voltage-free
contacts).
Profibus interface.
NET VISION: professional WEB / SNMP
interface for UPS monitoring and shutdown management of several operating
systems.
JNC: shutdown client for workstations and
servers for several operating systems.
OPManager: centralized monitoring
program for Windows and Linux via
SNMP.
Remote maintenance
DCG_84073
T.SERVICE:
maintenance
software
for continuous 24 / 7 monitoring of the
SOCOMEC UPS.
ISO 9001
FM 28237
www.socomec.com
ISO14001
EMS 553476
49
Single-phase
and three-phase
UPS from 10 to 40 kVA
high availability with high efficiency
TRUE ON-LINE
DOUBLE
CONVERSION
GAMME 125 A
Better performance
than the EU Code of Conduct
on efficiency of AC UPS
Your protection
for
50
Single-phase and
three-phase UPS
Range
Model
GP 110
GP 310
GP 115
GP 315
GP 120
GP 320
GP 330
Input / output
3/1
3/3
3/1
3/3
3/1
3/3
3/3
kVA
10
10
15
15
20
20
30
GP 340
3/3
40
20
Automatic bypass
Overload @ p.f. 0.8
Overload @ p.f. 0.9
Crest factor
EFFICIENCY (TV SD verified)
Online mode @ 50 % of load
Online mode @ 75 % of load
Online mode @ 100 % of load
Efficiency in ECO-MODE
ENVIRONMENT
Operating ambient temperature
Storage temperature range
Relative humidity
Maximum altitude
Noise level (ISO 3746)
UPS CABINET
Dimensions W x D x H (with standard batteries) (mm)
Weight (with standard batteries) (kg)
Degree of protection
Colours
STANDARDS
Safety
Performance and Topology
EMC standard
Product certification
Electrical options
10
9
15
13.5
20
18
30
27
40
36
Technical data
Voltage tolerance
Output frequency
Sn [kVA]
Pn [kW]
Input / output: 3/1
Input / output: 3/3
Parallel configuration
INPUT
Rectifier rated voltage
Input frequency
Power factor / THDI
OUTPUT
Output voltage
up to 6 units
400 V 3ph + N
50 / 60 Hz 10 %
0.99 / < 2.5 %
if 1ph +N 230 V 1 % (can be configured 220 / 240 V)
if 3ph +N 400 1 % (380 / 415 V configurable)
static load 1 % dynamic load in accordance with VFI-SS-111
50 / 60 Hz 2 % (configurable with generator from 1 % to 8 %)
nominal output voltage 15 % (configurable with generator from 10 % to
20 %)
125 % for 10, 150 % for 60
125 % for 5, 150 % for 30
3:1 (in accordance with EN 62040-3)
up to 96 %
up to 96 %
up to 95.5 %
up to 98 %
0 C to + 40 C (15 C to 25 C for best battery life)
- 5 to + 45 C (15 C to 25 C for best battery life)
0 % - 95 % without condensation
1000 m without de-rating (maximum 3000 m)
< 52 dB
< 55 dB
444x795x800
444x795x1000
444x795x1400
190
195
195
315
320
IP 20 (according to IEC 60529), IP 21 optional
RAL 7012, plastic front panels: dark grey
EN 62040-1 (TV SD certified), EN 60950-1
EN 62040-3 [VFI-SS-111]
EN 62040-2 (2nd Edition)
CE
Communication options
Remote panel.
ADC interface (configurable voltage-free
contacts).
Profibus interface.
NET VISION: professional WEB / SNMP
interface for UPS monitoring and shutdown management of several operating
systems.
UNIVISION-PRO: advanced user interface
via serial link and multiple shutdown
management for several operating
systems.
JNC: shutdown client for workstations and
servers for several operating systems.
OPManager: centralized monitoring program
for Windows and Linux via SNMP.
Remote maintenance
T.SERVICE:
maintenance
software
for continuous 24 / 7 monitoring of the
SOCOMEC UPS.
DCG_84073
ISO 9001
FM 28237
www.socomec.com
ISO14001
EMS 553476
51
Three-phase
UPS system
Storage solutions
The flexibility typical of MASTERYS
Green Power UPS range opens new
possibilities on the energy storage aspect of
your installation to get the maximum from the
high quality power supply.
The following features allow minimizing the
amount of battery cabinets for an equivalent
back-up time:
ultra high efficiency of 96 %,
very wide input voltage (-40 % / +20 %)
and frequency (45 Hz to 65 Hz) rectifier
acceptance without battery use,
wide selection of battery configurations,
thanks to a very flexible DC bus voltage,
Advanced interface
User-friendly graphic display
Gives a clear view of the UPS subassemblies
status and provides the user with a full
array of controls for their management.
High visibility LED status bar
Gives the UPS status in 3 colours: green,
yellow or red.
Easy procedures for start-up and
shutdown of the UPS
The display gives operators a step-by-step
multilingual descriptions of the operating
procedures.
Wide range of network connections
Extensive communication possibilities are
on offer, including: HTML page for remote
monitoring, SNMP agent sending TRAP to
network management station, email sent
according to events selection, MODBUS
TCP for BMS data transfer, SMS alert.
Shutdown agent
Allows sending a shutdown command to
stand-alone or virtual servers.
TRUE ON-LINE
DOUBLE
CONVERSION
GAMME 202 A
Better performance
than the EU Code of Conduct
on efficiency of AC UPS
Your protection
for
52
Three-phase
UPS
Innovative architectures
ACS
ACS
STATYS (STS)
Electrical options
GREEN 012 A GB
Load
STATYS (STS)
Load
Technical data
Sn [kVA]
Pn [kW]
Input / output:3/3
INPUT
Rectifier rated voltage
Voltage tolerances
Input frequency
Power factor / THDI
Bypass rated voltage
OUTPUT
Voltage
Voltage tolerance
Frequency
Automatic bypass
Total harmonic voltage distortion
Overload @ p.f. 0.8
Overload @ p.f. 0.9
Crest factor
Short circuit current
EFFICIENCY (TV SD verified)
Online mode @ 50 % of load
Online mode @ 75 % of load
Online mode @ 100 % of load
ECO MODE
ENVIRONMENT
Operating environment temperature
Relative humidity
Maximum altitude
Noise level (ISO 3746)
Paralleling units
UPS CABINET
Dimensions W x D x H (mm)
Weight (kg)
Degree of protection
Colours
STANDARDS
Safety (TV SD certified)
Performance
Electromagnetic compatibility (EMC)
Product declaration
DCG_84073
Green Power
80
72
100
90
120
108
400 V 3ph +N
20 % without derating, -40 % with 50 % of Pn
50 / 60Hz 10 %
>0.99 / <2.5 %
3ph +N 400 V
Communication options
400 V 3ph +N 1 %
static load 1 % dynamic load in accordance with VFI-SS-111
50 / 60Hz 0.02Hz
rated voltage output 15 % (configurable with generator from 10 % to 20 %)
<1 % with linear load / <3 % with non linear load
125 % for 10, 150 % for 60
125 % for 5, 150 % for 30
3:1
up to 2.7 x In
up to 3.7 x In
up to 96 %
up to 96 %
up to 95.5 %
up to 98 %
from 0C up to +40C (from 15C to 25C for maximum battery life)
0 % - 95 % without condensation
1000 m without derating (max. 3000 m)
< 60 dB (A)
<65dB (A)
up to 6
Remote panel.
ADC interface (configurable voltage-free
contacts).
Profibus interface.
NET VISION: professional WEB / SNMP
interface for UPS monitoring and shutdown management of several operating
systems.
JNC: shutdown client for workstations and
servers for several operating systems.
OPManager: centralized monitoring
program for Windows and Linux via
SNMP.
Remote maintenance
T.SERVICE:
maintenance
software
for continuous 24 / 7 monitoring of the
SOCOMEC UPS.
180
EN 62040-1, EN 60950-1-1
EN 62040-3 (VFI-SS-111)
EN 62040-2
CE
ISO 9001
FM 28237
www.socomec.com
ISO14001
EMS 553476
53
MASTERYS IP+
Single-phase
and three-phase
UPS from 10 to 80 kVA
high reliability in harsh industrial environments
Process continuity
Frontal access for input / output cabling,
spares replacement and preventative
maintenance.
Scalable power and high availability (using
redundancy) with the facility to parallel up
to 6 units.
Available
IP52
GAMME 140 A
models
54
Your protection
for
Single-phase and
three-phase UPS
Range
MASTERYS IP+
from 10 to 80 kVA
Model
IP+ 110
IP+ 310
IP+ 115
IP+ 315
IP+ 120
IP+ 320
IP+ 130
IP+ 330
IP+ 140
IP+ 340
IP+ 160
IP+ 360
IP+ 380
Input / output
3/1
3/3
3/1
3/3
3/1
3/3
3/1
3/3
3/1
3/3
3/1
3/3
3/3
kVA
10
10
15
15
20
20
30
30
40
40
60
60
80
Electrical options
Technical data
kVA
kW - Input / output: 3 / 1
kW - Input / output: 3 / 3
Parallel configuration(1)
INPUT
Nominal voltage
Input frequency
Power factor / THDI(2)
OUTPUT
Output voltage
Output frequency
Automatic bypass
Overload
Crest factor
PF acceptable without de-rating
EFFICIENCY
Online mode @ 50 % of load(4)
Online mode @ 75 % of load(4)
Online mode @ 100 % of load(4)
Efficiency in ECO-MODE
ENVIRONMENT
Operating ambient temperature
Storage temperature range
Relative humidity
Maximum altitude
Noise level (ISO 3746)
UPS CABINET
Dimensions W x D x H (mm) input / output: 3 / 1
Dimensions W x D x H (mm) input / output: 3 / 3
Weight (kg) input / output: 3 / 1
Weight (kg) input / output: 3 / 3
Degree of protection
STANDARDS
Safety
Performance and Topology
EMC standard
Product certification
10
9
9
15
13.5
13.5
20
18
18
30
27
27
up to 6 units
40
32
36
60
48
48
80
64
230
230
(1) With transformer on input / bypass side. (2) For source THDV <2 % and nominal load.
(3) Three-phase 220 - 230 - 240 V from 15 to 40 kVA. (4) With transformer on bypass side.
Standard communication
features
Multilanguage graphic display.
ADC interface (configurable voltage-free
contacts).
MODBUS / JBUS interface.
Modem / SMS interface.
Embedded LAN interface.
2 slots for communication options.
Communication options
Remote panel.
ADC interface (configurable voltage-free
contacts).
Profibus interface.
NET VISION: professional WEB / SNMP
interface for UPS monitoring and shutdown management of several operating
systems.
JNC: shutdown client for workstations and
servers for several operating systems.
OPManager: centralized monitoring
program for Windows and Linux via
SNMP.
Remote maintenance
DCG_84073
T.SERVICE:
maintenance
software
for continuous 24 / 7 monitoring of the
SOCOMEC UPS.