Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Standard E8900
Intrinsically safe Y8900
The E8900 is created by the use of a stainless steel pressure gauge
63, 100, 150 or 160 mm and the E910* pressure transmitter.
It has been designed for all industrial applications to allow both a local
pressure reading and remote signal transmission to a Programmable Logic
Controller or other computer-based system.
Specifications (20C)
Measurement range :
Compound pressure : -1 ... 0
Gauge pressure :
0 ... 1
Output signal :
E89X2 - Y89X2 :
E89X3 - Y89X3 :
E89X4 - Y89X4 :
E89X6 - Y89X6 :
to
to
-1 ... 24 bar
0 ... 600 bar
0 - 10 Vdc
4 - 20 mA (except -1 + 0 bar : -1 = 20 mA, 0 = 4 mA)
1 - 5 Vdc
0 - 20 mA
Supply voltage :
E89X2 :
14 to 40 Vdc Y89X2 :
14 to 28 Vdc
E89X3 - E89X4 : 11 to 40 Vdc Y89X3 - Y89X4 : 11 to 28 Vdc
E89X6 :
8 to 40 Vdc Y89X6 :
8 to 28 Vdc
Option :
high voltage: up to 48 Vdc
low voltage: 8 to 32 Vdc (E89X3, E89X4)
For intrinsically safe versions Y8900, power supply electrical
parameters device must be :
Usupply 28 Vdc ; I 120 mA ; P 0.8 W
Insulation :
Standard : > 100 M at 250 Vdc. Option: 500 Vdc.
Maximum input current :
E89X2 - Y89X2 / E89X4 - Y89X4 : 6 mA
E89X6 - Y89X6 : < 25 mA
11/00 - N 304005 GB
Load impedance (+ M / M) :
E89X2 - Y89X2 : 2,5 k.
E89X4 - Y89X4 : 1 k
E89X6 - Y89X6 : see diagrams overleaf
Electromagnetic compatibility :
Standards EN50082-1 and -2 (immunity)
Standards EN50081-1 and -2 (emission: a factor of 100
below the permitted Maximum)
with screened cable, screen connected at both ends
Modifications reserved
Load diagrams
Rc max. =
Rc load
Vsupply - 11
0,02
Vsupply - 8
0,02
Rc max. =
Rc load
1200
1450
Operating zone
Load Rc
1700
Operating zone
800
Operating area
650
11
40
24
24
32
100
0
E89X6 : 0 - 20 mA version
64
A = 105
4 ... 6
78
G1/4
Access to adjustments
62
kg
= 0,380
Connections
Connector DIN and Micro DIN
E/Y89X2/4/6
E/Y89X3
E/Y89X2/4/6
+Supply
+ Meas.
White
+Supply
- Supply
- Meas./-Supply
Blue
- Supply
+ Supply
Red
+Supply
Ground
Yellow
+ Meas.
3
Ground
Screen
40
- Meas./-Supply
TYPE F
101
91
6...8
35
6...8
A= 109
50.5
79
31.5
A= 110
35
G1/2
93
Electrical connection
110
kg
= 0,900
19
101
Electrical connection
109
108
107
101
100
kg
= 0,900
TYPE F
C= 150
D= 95
C= 150
A= 109
6...8
6...8
B= 100
A= 110
31.5
35
35
19
B= 97.5
G1/2
Electrical connection
110
kg
= 1,200
Electrical connection
109
108
107
101
100
kg
= 1,200
A = 110
B = 105
C = 160
D = 95
TYPE F
kg
= 1,300
A = 109
B = 97.5
C = 160
kg
= 1,300
Uncoded options
(1)
Lightning protection
Supply voltage (high/low)(1)
Ambient temperature (high/low)(1)
Compensated temperature range (- 10 to + 70C)
Zero thermal drift: 0.015% of range/C max.
Calibration of sensor with certificate: Q1060
B type of mounting (back connection + flange) for 100, 150 and 160 mm
(2)
(3)
Range
-1+5
6
12
60
120
100
200
160
320
250
500
400
600
600
800
* pressure gauge
Codification
8 9
Measurement ranges
in bar.
E
Y
Type :
E89/Y89
89
Dial diameter :
63
100
150
160
3
5
7
8
Output signal :
0-10 Vdc
4-20 mA standard
1-5 Vdc
0-20 mA
2
3
4
6
Type of mounting :
Bottom connection ( 63 - 100 - 150 - 160 mm)
Back connection ( 100 - 150 - 160 mm)
Hydraulic connection :
G 1/4 (standard 63 mm)
G 1/2 (standard 100 - 150 - 160 mm)
1/4 NPT
1/2 NPT
Cell O'Ring :
NBR (nitril) standard
Type of liquid filling :
Dry
BH1 filling (-20 to +70C)
BH3 filling (-25 to + 85C)
D
F
02
03
05
06
-1
-1
-1
-1
-1
-1
-1
-1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
0
0,6
1,5
3
5
9
15
24
1
1,6
2,5
4
6
10
16
25
40
60
100
160
250
400
600
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
3
0
1
3
Bourdon Sedeme - B.P. 214, 41103 Vendme cedex FRANCE - Tel. : +33 (0)2 54 73 74 75 - Fax France : +33 (0)2 54 73 74 74 - Fax Export : +33 (0)2 54 73 74 73
e-mail : bsf@bourdon-sedeme.com - Internet : www.bourdon-sedeme.com
Modifications reserved
Family :
Standard
Intrinsically safe