Section 3 - XLPE Insulated Cables

Unarmoured Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES


XLPE/PVC (IEC 60502-1)
CONSTRUCTION

TECHNICAL DATA

Conductor

: Plain Annealed Copper

Insulation

: XLPE Compound

Operating Temperature

Filler (if necessary)

: Suitable material

Maximum 90C

Sheath

: PVC Compound type ST2

Colour Ident.

: Insulation - Black with numbering code

Voltage

(to IEC 60228 clas 1)

Uo/U - 600/1000 V

Sheath - Black

CONTROL CABLE : 1.5 mm (Solid conductor)


Conductor
Diameter

Nominal

Nominal

Overall

Thickness

Thickness

diameter

Maximum

No

Nominal

No./

Weight

Conductor

of

Cross-section

Diameter

of

of

of

core

area

of wire

Conductor

Insulation

Sheath

of

of

Resistance

cable

cable

at 20C

(approx.)

(approx.)

(approx.)

(approx.)

mm

No./mm

mm

mm

mm

mm

kg/km

/km

1.5

1 / 1.38

1.38

0.7

1.8

13.0

214

12.1

1.5

1 / 1.38

1.38

0.7

1.8

13.0

229

12.1

1.5

1 / 1.38

1.38

0.7

1.8

14.0

256

12.1

1.5

1 / 1.38

1.38

0.7

1.8

15.0

286

12.1

10

1.5

1 / 1.38

1.38

0.7

1.8

16.0

316

12.1

12

1.5

1 / 1.38

1.38

0.7

1.8

16.5

358

12.1

14

1.5

1 / 1.38

1.38

0.7

1.8

17.5

400

12.1

15

1.5

1 / 1.38

1.38

0.7

1.8

18.0

426

12.1

16

1.5

1 / 1.38

1.38

0.7

1.8

18.5

448

12.1

18

1.5

1 / 1.38

1.38

0.7

1.8

19.0

488

12.1

19

1.5

1 / 1.38

1.38

0.7

1.8

19.0

502

12.1

20

1.5

1 / 1.38

1.38

0.7

1.8

19.5

532

12.1

24

1.5

1 / 1.38

1.38

0.7

1.8

22.0

628

12.1

30

1.5

1 / 1.38

1.38

0.7

1.8

23.5

748

12.1

32

1.5

1 / 1.38

1.38

0.7

1.8

24.0

793

12.1

37

1.5

1 / 1.38

1.38

0.7

1.8

25.0

888

12.1

40

1.5

1 / 1.38

1.38

0.7

1.8

26.0

953

12.1

50

1.5

1 / 1.38

1.38

0.7

1.9

29.0

1178

12.1

52

1.5

1 / 1.38

1.38

0.7

1.9

29.5

1221

12.1

60

1.5

1 / 1.38

1.38

0.7

1.9

31.5

1384

12.1

61

1.5

1 / 1.38

1.38

0.7

1.9

31.5

1398

12.1

Page - 57

Section 3 - XLPE Insulated Cables


Unarmoured Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES


XLPE/PVC (IEC 60502-1)
CONSTRUCTION

TECHNICAL DATA

Conductor

: Plain Annealed Copper

Insulation

: XLPE Compound

Operating Temperature

Filler (if necessary)

: Suitable material

Maximum 90C

Sheath

: PVC Compound type ST2

Colour Ident.

: Insulation - Black with numbering code

Voltage

(to IEC 60228 clas 2)

Uo/U - 600/1000 V

Sheath - Black

CONTROL CABLE : 1.5 mm (Stranded conductor)


Conductor

Page - 58

Diameter

Nominal

Nominal

Overall

Thickness

Thickness

diameter

Maximum

No

Nominal

No./

Weight

Conductor

of

Cross-section

Diameter

of

of

of

core

area

of wire

Conductor

Insulation

Sheath

of

of

Resistance

cable

cable

at 20C

(approx.)

(approx.)

(approx.)

(approx.)

mm

No./mm

mm

mm

mm

mm

kg/km

/km

1.5

7 / 0.52

1.56

0.7

1.8

14.0

224

12.1

1.5

7 / 0.52

1.56

0.7

1.8

14.0

239

12.1

1.5

7 / 0.52

1.56

0.7

1.8

15.0

269

12.1

1.5

7 / 0.52

1.56

0.7

1.8

16.0

300

12.1

10

1.5

7 / 0.52

1.56

0.7

1.8

17.0

331

12.1

12

1.5

7 / 0.52

1.56

0.7

1.8

17.5

374

12.1

14

1.5

7 / 0.52

1.56

0.7

1.8

18.5

418

12.1

15

1.5

7 / 0.52

1.56

0.7

1.8

19.0

447

12.1

16

1.5

7 / 0.52

1.56

0.7

1.8

19.0

468

12.1

18

1.5

7 / 0.52

1.56

0.7

1.8

20.0

511

12.1

19

1.5

7 / 0.52

1.56

0.7

1.8

20.0

526

12.1

20

1.5

7 / 0.52

1.56

0.7

1.8

21.0

557

12.1

24

1.5

7 / 0.52

1.56

0.7

1.8

23.5

657

12.1

30

1.5

7 / 0.52

1.56

0.7

1.8

24.5

786

12.1

32

1.5

7 / 0.52

1.56

0.7

1.8

25.0

830

12.1

37

1.5

7 / 0.52

1.56

0.7

1.8

26.5

928

12.1

40

1.5

7 / 0.52

1.56

0.7

1.8

27.5

997

12.1

50

1.5

7 / 0.52

1.56

0.7

1.9

30.5

1232

12.1

52

1.5

7 / 0.52

1.56

0.7

1.9

31.5

1276

12.1

60

1.5

7 / 0.52

1.56

0.7

1.9

33.0

1447

12.1

61

1.5

7 / 0.52

1.56

0.7

1.9

33.0

1462

12.1

Section 3 - XLPE Insulated Cables


Unarmoured Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES


XLPE/PVC (IEC 60502-1)
CONSTRUCTION

TECHNICAL DATA
: Plain Annealed Copper

Conductor

Voltage

(to IEC 60228 class 1)

Uo/U - 600/1000 V

Insulation

: XLPE Compound

Operating Temperature

Filler (if necessary)

: Suitable material

Maximum 90C

Sheath

: PVC Compound type ST2

Colour Ident.

: Insulation - Black with numbering code


Sheath - Black

CONTROL CABLE : 2.5 mm (Solid conductor)


Conductor
Diameter

Nominal

Nominal

Overall

Thickness

Thickness

diameter

Maximum

No

Nominal

No./

of

Cross-section

Diameter

of

of

of

area

of wire

Conductor

Insulation

Sheath

(approx.)

(approx.)

(approx.)

(approx.)

mm

No./mm

mm

mm

kg/km

/km

2.5

1 / 1.78

1.78

0.7

1.8

14.5

284

7.41

2.5

1 / 1.78

1.78

0.7

1.8

14.5

307

7.41

2.5

1 / 1.78

1.78

0.7

1.8

15.5

348

7.41

2.5

1 / 1.78

1.78

0.7

1.8

16.5

389

7.41

10

2.5

1 / 1.78

1.78

0.7

1.8

18.0

431

7.41

12

2.5

1 / 1.78

1.78

0.7

1.8

18.5

490

7.41

14

2.5

1 / 1.78

1.78

0.7

1.8

19.0

558

7.41

15

2.5

1 / 1.78

1.78

0.7

1.8

19.5

590

7.41

16

2.5

1 / 1.78

1.78

0.7

1.8

20.0

622

7.41

18

2.5

1 / 1.78

1.78

0.7

1.8

21.0

684

7.41

19

2.5

1 / 1.78

1.78

0.7

1.8

21.0

707

7.41

20

2.5

1 / 1.78

1.78

0.7

1.8

22.0

754

7.41

24

2.5

1 / 1.78

1.78

0.7

1.8

24.5

887

7.41

30

2.5

1 / 1.78

1.78

0.7

1.8

26.0

1070

7.41

32

2.5

1 / 1.78

1.78

0.7

1.8

26.5

1131

7.41

37

2.5

1 / 1.78

1.78

0.7

1.8

28.0

1276

7.41

40

2.5

1 / 1.78

1.78

0.7

1.9

29.0

1386

7.41

50

2.5

1 / 1.78

1.78

0.7

2.0

32.5

1714

7.41

52

2.5

1 / 1.78

1.78

0.7

2.0

33.0

1782

7.41

60

2.5

1 / 1.78

1.78

0.7

2.0

35.0

2024

7.41

61

2.5

1 / 1.78

1.78

0.7

2.0

35.0

2046

7.41

core

mm

mm

Weight

Conductor

of

of

Resistance

cable

cable

at 20C

Page - 59

Section 3 - XLPE Insulated Cables


Unarmoured Cables

600/1000 V XLPE INSULATED AND PVC SHEATHED CABLES


XLPE/PVC (IEC 60502-1)
CONSTRUCTION

TECHNICAL DATA
: Plain Annealed Copper

Conductor

Voltage

(to IEC 60228 class 2)

Uo/U - 600/1000 V

Insulation

: XLPE Compound

Operating Temperature

Filler (if necessary)

: Suitable material

Maximum 90C

Sheath

: PVC Compound type ST2

Colour Ident.

: Insulation - Black with numbering code


Sheath - Black

CONTROL CABLE : 2.5 mm (Stranded conductor)


Conductor

Page - 60

Nominal

Nominal

Overall

Thickness

diameter

Maximum

Nominal

No./

of

Cross-section

Diameter

of

of

of

area

of wire

Conductor

Insulation

Sheath

(approx.)

(approx.)

(approx.)

(approx.)

mm

No./mm

mm

mm

kg/km

/km

2.5

7 / 0.67

2.01

0.7

1.8

15.0

296

7.41

2.5

7 / 0.67

2.01

0.7

1.8

15.0

320

7.41

2.5

7 / 0.67

2.01

0.7

1.8

16.0

362

7.41

2.5

7 / 0.67

2.01

0.7

1.8

17.0

405

7.41

10

2.5

7 / 0.67

2.01

0.7

1.8

18.5

449

7.41

12

2.5

7 / 0.67

2.01

0.7

1.8

19.0

510

7.41

14

2.5

7 / 0.67

2.01

0.7

1.8

20.0

580

7.41

15

2.5

7 / 0.67

2.01

0.7

1.8

20.5

614

7.41

16

2.5

7 / 0.67

2.01

0.7

1.8

21.0

647

7.41

18

2.5

7 / 0.67

2.01

0.7

1.8

22.0

712

7.41

19

2.5

7 / 0.67

2.01

0.7

1.8

22.0

736

7.41

20

2.5

7 / 0.67

2.01

0.7

1.8

23.0

784

7.41

24

2.5

7 / 0.67

2.01

0.7

1.8

26.0

923

7.41

30

2.5

7 / 0.67

2.01

0.7

1.8

27.5

1114

7.41

32

2.5

7 / 0.67

2.01

0.7

1.8

28.0

1177

7.41

37

2.5

7 / 0.67

2.01

0.7

1.8

29.5

1328

7.41

40

2.5

7 / 0.67

2.01

0.7

1.9

30.5

1443

7.41

50

2.5

7 / 0.67

2.01

0.7

2.0

34.0

1784

7.41

52

2.5

7 / 0.67

2.01

0.7

2.0

35.0

1854

7.41

60

2.5

7 / 0.67

2.01

0.7

2.0

37.0

2105

7.41

61

2.5

7 / 0.67

2.01

0.7

2.0

37.0

2129

7.41

core

Diameter

Thickness

No

mm

mm

Weight

Conductor

of

of

Resistance

cable

cable

at 20C