Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Unique Features
State of the art products with SMT : Compact & reliable.
Well proven technology from Gossen Metrawatt Camille
Bauer, Germany / Switzerland.
Application
Accuracy class 0.5 as per IEC 688, (I22 & V22 class 0.2.)
Current :
Voltage :
Meaning
Symbols
Meaning
Y2
X0
Power supply
X1
Hn
X2
Setting time
Tn
Y0
Rext
Y1
Rn
Rishabh Instruments
I / 04 / I / 1107
Standard Transformation
Characteristics
Block Diagram
T2
1
w T x i dt
o
T2
1
x l dt
leff = w
T
o
H
Y
Y2
Y0
X0
T 2
1
w T x u dt
o
T 2
1
x U dt
Ueff = w
T
o
X2
Y
Y2
Y0
X0
X2
W
I~
VK
U~
Rext
G
G
~
I~
U~
A
-
Fig. 3.
Block Diagram
for transducer
with live-zero
output & 2-wire
connection.
Fig. 4.
Block Diagram for
transducer with
unipolar output.
Y2
1
5A 1A 3
T
5-
A
6+
Y0
X0
X2
Rishabh Instruments
I / 04 / I / 1107
Parameter
Safety Standards
Housing Protection
Rated Insulation
Voltage
Contamination
Level
I21
I22
V21
V22
I12
---
---
---
---
Over voltage
Category
III
---
---
Protection Class
II
---
---
Safe Isolation
---
---
Impluse withstand
Voltage
Acc to
IEC 255-4 CI,III:
5 KV 1.2/ 50 m
sec, 0.5 Ws Common - mode --and differential mode between any terminals
Test Voltage
10 Product
Performance
5 KV 1.2/50 m
sec, 0.5 Ws Commonmode and differential mode between
any terminals
Rishabh Instruments
I / 04 / I / 1107
1 Measured
Quantity
RISH
Ducer I21
RISH
Ducer I22
Logarithmic
Measuring
Input
Current
50, 60 or
400 Hz
2 Nominal
Input *
Current X2 : 1A
X2
7.5 A
5 Overload
Capacity
RISH
Ducer I12
50, 60 Hz
50, 60 or
400 Hz
Rectifier method
Current
50, 60 Hz
Voltage X2 :
100 V
X2
7.5 A
---
RISH
Ducer I11 & V11
Voltage
1 Nominal
Frequency
FN
4 Own
Consumption
RISH
Ducer V22
AC Current
AC Voltage
Sine or distorted waveforms
Sine or distorted waveforms
True RMS value measurement True RMS value measurement
2 Measured
Principle
3 Re-calibration
of X2
RISH
Ducer V21
Current :
1A & 5 A
Site
configurable
Current IN 1A or 5A
---
Range adjustment
0.9...1.1. IN resp. UN (+10%)
(Admissible alternation of full
scale output, variable sensitivity,
adjustable with potentionmeter)
Voltage VN
100 / 3 / 110 / 150 /
240 / 415 / 440 V *
w
At nominal freq. Hz :
Full o/p
I11 V11
Value [mA] [VA] [VA]
1
0.8 0.8
5
1.8 1.2
10
2.2 1.5
20
2.5 1.8
Measured No. Duration Interval
Measured No. Duration Interval
Measured No. of Duration Interval
1.2 X IN
Quantity of
of 1
between 2 Quantity of
of 1
between 2
Quantity Appl. of 1
between 2
continuously
Appln successive
Appl. Appln
successive
Appl. Appln successive
appln.
appln.
appln.
2.
X2
----1.2 .
X 2 --1.5 X IN Cont.. ----Cont..
Cont.. --10 .
X2 5
5 s.
1.5 .
X 2 10 10s
10 min
2 X IN
10
10 s.
3s
10s
1h
10 X IN 5
5 min
1s
3s
50 .
X 2@ 1
40 X IN 1
--1s
X2 = Final value,
1.5 X VN Cont.. ----@
but max.250 A
2 X VN
10
10 s
10s
4 X VN
1
--2s
< 1 VA at X2
1 VA
Rishabh Instruments
I / 04 / I / 1107
Parameter
I21
I22
V21
V22
I12
Output
Variable Y
Load
independent
DC current
output range
1 mA
Y2
20 mA
0...5 mA
0...10 mA
0...20mA
O/p burden
with DC
current o/p
signal
0
R
15V/Y2
Rext max.[KW
]=
Rext max.[KW
] = 15 V/IAN [mA]
15 V/I AN [mA]
IAN = full o/p value
IAN = full o/p value
DC voltage
o/p range
1V
Y2
10 V
O/p burden
with DC
voltage o/p
signal
10 V
0...1/0...5/0...10 or 0...20 mA
(4...20mA refer cl. for 2 wire output)
100 KW
Ext resistance
200 kW
/v
Y2 / 2mA
R<
3 X IAN
Voltage
40 V with Current o/p
limit under
1.7.Y2 with voltage o/p
R ext =
< 20 V
< 24 V
Residual
ripple in o/p
signal
5% p.p. at
setting time 50 ms
0.5% p.p. at
Response
time
300 ms standard,
50 ms optional
< 2s
< 300 ms
10
Output
Standard
Ranges *
Current : 0-1mA/5mA/10mA/20mA/4-20mA
Voltage : 0-10V
Current : 0...5 /
0...10 /
0...20 mA
Voltage : 0-10V
1% p.p at
5% p.p. at setting time 50
750 W
/20 mA
ms and C
1
5% p.p. + C 0.5% at
setting time 50 ms and C > 1
Current ripple
1% p.p.
Rishabh Instruments
I / 04 / I / 1107
Parameter
I21
I22
V22
I12
I11
Reference Value
Basic Accuracy
(for std ranges)
V21
Class 0.5
Class 0.2
V11
Class 0.5
Class 0.2
Class 0.5
Class 0.5
Reference Conditions
Parameter
I21
I22
V21
V22
23 C, + 5 k
Ambient Temp
Input Variable
I12
0
I11
0
V11
0
23 C, + 1 C
23 C, + 5 k
0 to 100% for current measurement
20 to 100 % for voltage measurement
Frequency
Fn + 2%
Distortion Factor
---
External Resistance
Current o/p
Voltage o/p
< 0.5%
Rn = 15 V/Y2 + 1%
Rn = Y2/1 mA + 1%
Rext. Max - 1%
Rext. Min + 1%
Curve Shape
Sine - Wave
Shape Factor
1.1107
Curve Shape
Hn + 1%
---
Warm-up Time
O - R ext Max.
R ext Max to
5 min.
Environmental Condition
Sr.
No.
Parameter
Climatic Rating
Operating Temperature
Storage Temperature
Relative Humidity of
Annual Mean
Permissible Vibration
Shock
I21
I22
V21
V22
I12
I11
V11
75%
2 g acc. To EN 60 068-2-6
3 x 50 g
3 shocks each in 6 directions
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
Web-site : www.rishabh.co.in
Rishabh Instruments
I / 04 / I / 1107
Parameter
Linearity Error
Frequency
Dependance on
External resistance
d
R ext max.
I21
V21
I22
V22
< + 0.1%
----
----
+ 0.1%
I12
----
+ 0.1%
+ 0.5% + 0.1%
Additional Error *
1.
2.
3.
Ambient Temp
Curve Shape of
Input
Rated Operating
Range
Permitted
effect factor of
precision class
Rated Operating
Range
Permitted
effect factor of
precision class
+ 100 c...230 c
...400 c
Usage group
0
0
0...23 c ... 45 c
+ 00 c...230 c
...550 c
+ 100 c...230 c
...550 c
Rectangle 1:1
Rectangle 1:1
45..65 Hz
---
---
45...55Hz
+ 0.3%
45...200Hz
+ 0.5%
Rishabh Instruments
I / 04 / I / 1107
I21
Version with AC
Power packs
standard voltage :-
Rated operating
range of
frequency :
I22
V21
V22
Rated Value
Hn
AC
AC
AC
AC
22...26V
99...121V
207...253V
360...440V
24 V
110 V
230 V
400 V
I12
I11
V11
---
---
---
---
45...50...60...65 Hz
External Resistance AC
4 VA at
H=Hn
Current o/p
DC
4w
Voltage o/p
Version with
AC / DC
Power Packs
(Dc & 45 -- 400 Hz)
AC
3 VA at
H=Hn
DC
3w
Rated Value
Un
24...60 V
DC/AC
85...230 V
DC/AC
AC
4 VA at
H=Hn
DC
4w
AC
3 VA at
H=Hn
DC
3w
Permissible
Variation
DC - 15...+33%
AC + 15%
Power consumption
1.4 W resp.
2.7 VA
DC Voltage
Supply
---
---
---
12-30 V
(only for 2-wire connection with
output 4 ...20 mA)
Instillation Data
Sr.
No.
1
Parameter
I21
I22
V21
V22
I12
Mechanical Design
Material of Housing
Mounting
Mounting Position
Any
Electrical Connection
Weight
Approx. 0.5 Kg
I11
V11
Approx. 0.4 Kg
RISHABH INSTRUMENTS PVT.LTD.
F-31, MIDC, Satpur, Nashik-422 007,India.
Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064
E-mail : India :- marketing@rishabh.co.in
International :- exp.marketing@rishabh.co.in
Web-site : www.rishabh.co.in
Rishabh Instruments
I / 04 / I / 1107
2 Wire output with 4-20 mA, for I11 & V11 with 12...30V DC AUX :
With 2 wire connection
External
resistance [ ]
900
Fig . 9
600
24
30
2)
3)
H[V] - 12V
20mA
A) Bent Characteristics.
Factor c (V21)
Fig. 10
Output
Linear Curve = 1
BENT Curve
x2
1
c=
or c =
x1
1 x1
x2
(the larger value applies)
0
0
Input
Fig. 11
Characteristic B
Voltage magnifier in end range.
E1...E2 suppressed completely,
E2...E3 main measuring range magnified
E
A1
E1
E2
EN
E3
Rishabh Instruments
I / 04 / I / 1107
A3
A
A3
A3
A2
A1
A1
E
E1 E2
A1
E
E1
E3
E2
EN
E
E1
E3
E2
EN
E3
Fig. 12
Fig. 13
Fig. 14
A3
A3
A3
A3
A2
A2
E1
E3
A1
Fig. 15
Characteristic A Standard
and live zero. "
E1
A1
E3
E1
Fig. 16
Characteristic A Standard
Variable sensitivity and live
zero.
E3
Fig. 17
Characteristic A Standard
A1
E1
E3
Fig. 18
Characteristic A Standard
and variable sensitivity." E3
adjustable by max. + 5%
or + 10%
Y2
Y1
Y2
Y1
Y0
Y0
X
X0
X1
X2
Fig. 19
Bent curve,
characteristic
(X0 = 0 0.05 X2 < X1 < 0.9 X2
Y0 = 0 Y0 < Y1 < 0.9 Y2).
X
X0
X1 X2
Fig. 20
Bent curve,
characteristic
(X0 = 0 0.05 X2 < X1 < 0.9 X2
Y0 = 0.2 Y2 Y0 < Y1 < 0.9 Y2).
Rishabh Instruments
I / 04 / I / 1107
Output
Rext
-
5 6 7 8
5 6 7 8
+
5 6 7 8
1 2 3 4
~
A
Input
1 2 3 4
~
V
Input
1 2 3 4
~
A
Input
Rext
-
+
5 6 7 8
1 2 3 4
~
V
Input
I11,V11
Connection
Connecting
terminals
Measuring input E
1A~
1 and 3
Measuring input E
5A~
1 and 2
Measuring output A
5 - and 6 +
Connection
Terminals
Connection
Terminals
Measuring input
~
~
1
3
Measuring input
~
~
2
5
Measuring Output
+
-
13
14
Measuring Output
+
-
13
14
Power supply
~,+
~,-
21
22
Power supply
~,+
~,-
21
22
I12
I21 / I22
V21 / V22
Dimensional Drawing
19
4.5
6.5
7 8
140
7 8
125
130
125
5 6
154
5 6
1 2 3 4
1
2 3
126
12
125
35
35
Rishabh Instruments
I / 04 / I / 1107
Features Selection
Re-calibration of X2
Final value permanently set
Final value can be adjusted
in range 0.5 X2 < X2
Response time
Power Supply
Not applicable
Specify range
Not applicable
Specify range
V21
V22
I21
I22
X0 = 0
Y0 = 0.2.Y2
Voltage
Transducer
Current
Transducer
Specify range
Not applicable
Not applicable
Not applicable
Specify value
50ms
0.3s (standard)
AC 22 V...26V
AC 99V...121V
AC 108V...132V
AC 207V...253V
AC 360V...440V *
DC/AC 24V...60V
DC/AC 85V...230V
Rishabh Instruments
I / 04 / I / 1107
Features Selection
1)
2)
3)
Current
Voltage
Transducer
Transducer
I 11
Specify range
Not applicable
V 11
Not applicable
Specify range
Special Feature
Without
With (Specify separately)
Note :
Please tick
in appropriate box
Also specify the ranges wherever necessary
** other specifications on request. (Contact to factory)
Rishabh Instruments
I / 04 / I / 1107